SLOPE INDICATOR Geotechnical Instruments

Size: px
Start display at page:

Download "SLOPE INDICATOR Geotechnical Instruments"

Transcription

1 SLOPE INDICATOR Geotechnical Instruments Environmental Products Materials Testing Equipment

2 Profile Offices in the USA, Canada, Australia and China. Manufacturing in Stone Mountain, GA. and Mukilteo, WA. Over One hundred employees. Recognized leader in Environmental Products & Geotechnical Instrumentation. In house manufacturing and engineering Experience

3 Manufacturing Stone Mountain, GA (30,000 ft²) Mukilteo, WA (22,000 ft²). 11,000 orders per year with more than 15,000 P/N ISO certification in R&D by electronic and mechanical engineers, supported by an industrial designer and a software developer.

4

5 Operation of a Pneumatic Pump

6 Why Use Pneumatic Pumps Durability No XP Concerns Ideal for lower flow rates Handle High Temperature Relatively Simple No external controller Solids handling Re-Buildable Adjustable flow rates

7 Applications for Pneumatic Pumps Condensate Sumps Dewatering Gas wells to optimize gas collection Vertical leachate wells where central collections pumps are not used Vertical leachate wells to remove perched liquid zones

8 Sludge

9 Corrosion

10 Mineral Deposits

11 Plating Precipitation

12 Float Maintenance

13 Neglect

14 Critical Pump Design Elements Air Valve Control Rod Float Buoyancy Weight Material Compatibility

15 Our engineers have used their 25+ years of experience with pneumatic pumps in landfills to design and build the new generation pump SRX-LP specifically for tough landfill duty.

16 Introducing

17 Simply Reliable

18 SIMPLY RELIABLE Few parts Simple design Innovative Features Made for high temperatures Endures harsh environments

19 Few Parts Discharge Check Valve Posi-Seal Air Valve Stainless Steel Pump Body.065 Wall Ebonite, Hi-temp 250 F, Non-porous Float Bottom Dome Inlet Assembly

20 Easy to Disassemble Click in White Area to Play Movie Discharge Check Valve Discharge Check Valve Stainless Steel pump Body.065 Wall

21 Easy to Disassemble Use Only One Wrench

22 Easy to Disassemble Click in White Area to Play Movie

23 SRX LP PUMP HEAD Isolated High-Temperature Magnet Hydlar Friction Bushing Posiseal Air valve Control Rod

24 SRX LP Air Valve Posi-Seal air valve provides a bubble-tight seal preventing leakage that can lead to unnecessary precipitation. The air/exhaust valves can be totally accessed without taking the pump apart no special tools are required. Filter screen in the air valve assembly prohibits the entry of debris. 330 mesh, stainless steel.

25 SRX LP Air Exhaust Valve Accessed from the top of the pump without disassembling the pump body. Simply unthread.

26 SRX LP Fluid Discharge Check Unthread the hose barb Remove the retaining pin for complete access to the ball/seat assembly

27 SRX LP CONTROL ROD Control Rod Lightweight control rod assists valve operation and is isolated from stress

28 SRX LP Pump Float Custom design Cast Ebnoite float rated for temperatures up to 250 degrees Hard non porous surface to reduce precipitation build up Control rod cavity is open for easy cleaning

29 SRX Assembly

30 QC Testing

31 Air Requirements.5 PSI per foot of depth Maximum air usage is 1 CFM per GPM Install filter regulator at the well head SRX air valve can tolerate dirty wet air

32 ACCESSORIES Nylon Bundled Tubing Assembly Air In: ID: in OD: in Air Out ID: in OD: in Discharge ID: 1.0 in OD: in

33 ACCESSORIES Pulse Counter Filter / Regulator Well Head Module

34 Well Seals ACCESSORIES Simplifies Installation and connection of fluid and air lines Manifold flanges, Air In / Fluid Out Kit, additional Parts Additional ports allow for level or pressure measurements Configurations for liquid only or gas/liquid combination. Flow control kits; exhaust diversion kits.

35 Documented Well Seals

36 Multi Use Well Seal 2 or 3 Well Head Fluid and Air Ports Water Level Port

37 What Is Corrosion Corrosion is a state of deterioration of essential properties in a material, typically metals due to chemical reactions, oxidation or the loss of electrons. Generally begins at weld joints on the metal

38 Managing Corrosion Zinc Anode

39

40 THE WEIGHT OF THE ATMOSPHERE OR GAS INSIDE THE PUMP IS THE SAME AS OUTSIDE. OUT IN DISCHARGE ACTIVATION LIQUID LEVEL When the exhaust port and the well are open to atmosphere or when the exhaust line is inside the well the liquid level inside the pump to start the discharge cycle is as shown. The gas pressure inside the pump and outside the pump are the same. Only the higher liquid level outside the pump will cause it to fill to the cycle activation level

41 The well flange seals the top of the well and all the tubing penetrations the pump exhaust tubing is open to the atmosphere PARCEL VACUUM = Z INCHES WATER THE WEIGHT OF THE ATMOSPHERE OR GAS INSIDE THE PUMP IS GREATER THAT OUT SIDE THE PUMP. NEW ACTIVATION LIQUID LEVEL THE NEW ACTIVATION IS Z IN INCHES OF WATER + THE ORIGONIAL SET POINT. 0UT SIDE IN SIDE ORIGONIAL LIQUID ACTIVATION LEVEL When the exhaust port is open to the atmosphere and the well is under partial vacuum the liquid level in the casing to fill the pump and activate the discharge cycle will be increased by the applied vacuum.

42 EQUALIZATION EXHAUST VALVE ½ O.D. push to connect fittings on both top and bottom of valve. Cut ½ DGSI nylon exhaust tubing below the well seal and above highest liquid level and install valve. Note flow direction arrows on valve. Exhaust valve Bleed Orifice 0.031

43 E Valve

44 Exhaust check valve Note : High pressure exhaust Exits open end of this valve VACUUM ASSIST EXHAUST VALVE AND PUMP VACUUM CONNECTIONS ¼ push to connect tube fittings. Connect these two fittings together with tubing supplied Vacuum gage One inch mercury equals 13.6 inches of water Pressure regulator with gage. An increase in pressure will increase the vacuum generated by the pump ½Inch push to connect tube fitting Attach to ½ O.D. DGSI bundled exhaust tube outside well seal Muffler due not block open end Air venture vacuum pump 3/8 push to connect tee. Cut the 3/8 DGSI nylon pump air supply tube above the well seal and insert tee

45 Common Questions Q - How deep can I install the pump A - Pumps are rated for 100 PSI so that translates to 231 ft Q After I have had the air supply turned off to the pump it seems to take a while before it starts cycling properly A With the air supply turned off the float moves to the on position allowing the liquid to fill the air line therefore air has to purge the liquid from the air supply

46 Common Questions Q Why is liquid discharging from the air exhaust line A This is normal after the air supply has been shut off. The liquid will fill the exhaust line equal to the static well level. The discharge should stop after cycles

47 What Customers Say The SRX pump is so simple, it works and the pricing is hundreds less than what we are currently paying.

48 What Customers Say We know that maintenance will be required on our landfill pumps and the SRX pump makes that process so much simpler. We estimate that our service time will be cut in half and no expensive replacement parts.

49 What Customers Say The SRX pump is so easy to take apart no special wrenches no adjustments the domed bottom is great for installation.

50 SIMPLY RELIABLE Any questions?

SRX R. Remediation Pumps. Simply Reliable

SRX R. Remediation Pumps. Simply Reliable SRX R Remediation Pumps Simply Reliable The SRX pump is based on a simple, innovative design and built with fi eld-proven components. The result: a reliable pump to meet the demands of your remediation

More information

SRX. Remediation Pumps. Simply Reliable

SRX. Remediation Pumps. Simply Reliable SRX Remediation Pumps Simply Reliable The SRX is a based on a simple, innovative design and built with fi eld-proven components. The result: a reliable pump to meet the demands of your remediation site.

More information

Crispin Valves Operating Guide. Crispin

Crispin Valves Operating Guide. Crispin Crispin Valves Operating Guide Crispin Since 1905 Crispin Multiplex Manufacturing Co. 600 Fowler Avenue Berwick, PA 18603 1-800-AIR-VALV T: (570) 752-4524 F: (570) 752-4962 www.crispinvalve.com sales@crispinvalve.com

More information

User Manual. MVP IV Series Groundwater Pumps. Version 2.2. Durham Geo Slope Indicator 2175 West Park Court Stone Mountain, GA USA

User Manual. MVP IV Series Groundwater Pumps. Version 2.2. Durham Geo Slope Indicator 2175 West Park Court Stone Mountain, GA USA MVP IV Series Groundwater Pumps User Manual Version 2.2 Durham Geo Slope Indicator 2175 West Park Court Stone Mountain, GA 30087 USA Phone: 800-837-0864 or +1.770.465.7557 Fax: 770.465.7447 e-mail: solutions@durhamgeo.com

More information

OPERATION MANUAL. ALUMINUM Models. 316 S.S. Models NTG25 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 1/14 rev.

OPERATION MANUAL. ALUMINUM Models. 316 S.S. Models NTG25 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 1/14 rev. OPERATION MANUAL NTG25 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS ALUMINUM Models 316 S.S. Models A JDA Global Company 1/14 rev. 3 CAUTION SAFETY POINTS TEMPERATURE LIMITS: Neoprene -17.8 C to

More information

PURESTREAM SYSTEM - ASSEMBLY GUIDE

PURESTREAM SYSTEM - ASSEMBLY GUIDE PURESTREAM SYSTEM - ASSEMBLY GUIDE INSTRUCTION VIDEO LINK: www.cagpurification.com/installment--procedure--videos.aspx OR SCAN CODE BELOW pipes fittings for compressed air NECESSARY TOOLS FOR INSTALLATION

More information

OPERATION MANUAL NT50 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 7/11 rev. 1

OPERATION MANUAL NT50 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 7/11 rev. 1 OPERATION MANUAL NT50 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS A JDA Global Company 7/11 rev. 1 CAUTION SAFETY POINTS TEMPERATURE LIMITS: Neoprene -17.8 C to 93.3 C 0 F to 200 F Buna-N -12.2

More information

O-Ring Face Seal Hose

O-Ring Face Seal Hose Hose TRADITIONAL HIGH VIBRATION HOSE SYSTEM THE STANDARD FOR MANY AUTOMOTIVE APPLICATIONS THE STANDARD FOR MANY AUTOMOTIVE APPLICATIONS Table of Contents Page Introduction... 1 Safety Guidelines... 2 Control

More information

Installation, Operation & Service Manual. PPL Bag Filter Housings. Table of Contents Page No. Eaton Filtration, LLC

Installation, Operation & Service Manual. PPL Bag Filter Housings. Table of Contents Page No. Eaton Filtration, LLC Installation, Operation & Service Manual PPL Bag Filter Housings Eaton Filtration, LLC 900 Fairmount Avenue, Elizabeth, NJ 07207 Read all instructions before installation or operation of equipment. Failure

More information

OPERATION MANUAL NT80 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 5/13 rev.2

OPERATION MANUAL NT80 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 5/13 rev.2 OPERATION MANUAL AIR-OPERATED DOUBLE DIAPHRAGM PUMPS A JDA Global Company 5/13 rev.2 CAUTION SAFETY POINTS TEMPERATURE LIMITS: Neoprene -17.8 C to 93.3 C 0 F to 200 F Buna-N -12.2 C to 82.2 C 10 F to 180

More information

OPERATION MANUAL. DUCTILE Models NT100 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 5/13 rev.2

OPERATION MANUAL. DUCTILE Models NT100 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 5/13 rev.2 OPERATION MANUAL NT100 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS DUCTILE Models A JDA Global Company 5/13 rev.2 CAUTION SAFETY POINTS TEMPERATURE LIMITS: Neoprene -17.8 C to 93.3 C 0 F to 200

More information

Welker Sampler. Installation, Operation, & Maintenance Manual. Model GSS-4HP

Welker Sampler. Installation, Operation, & Maintenance Manual. Model GSS-4HP Installation, Operation, & Maintenance Manual Welker Sampler Model GSS-4HP The information in this manual has been carefully checked for accuracy and is intended to be used as a guide to operations. Correct

More information

Mars Series 88 Stainless Steel Reduced Bore Or Full Bore Ball Valve, Lever Operated, BSP Or Socket Weld Ends

Mars Series 88 Stainless Steel Reduced Bore Or Full Bore Ball Valve, Lever Operated, BSP Or Socket Weld Ends SPECIFICATION See our full range online at: www.vip-ltd.co.uk Mars Series 88 Stainless Steel Reduced Bore Or Full Bore Ball Valve, Lever Operated, BSP Or Socket Weld Ends VIP Product Codes 04/0466 (BSP)

More information

Composite Push-In Fittings BSP/Metric Series 7000

Composite Push-In Fittings BSP/Metric Series 7000 2 Composite Push-In Fittings BSP/Metric Series 7000 NORTH AMERICAN FITTINGS & FLOW CONTROL VALVE CATALOG > Release 8.6 Tube Diameter OD: 4, 6, 8, 10, 12, 16 mm Thread Type: metric (M5, M7), BSP (G1/8,

More information

OPERATION MANUAL. ALUMINUM Models. 316 S.S. Models NTG50 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 1/14 rev.

OPERATION MANUAL. ALUMINUM Models. 316 S.S. Models NTG50 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 1/14 rev. OPERATION MANUAL NTG50 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS ALUMINUM Models 316 S.S. Models A JDA Global Company 1/14 rev.3 CAUTION SAFETY POINTS TEMPERATURE LIMITS: Neoprene -17.8 C to

More information

OPERATION MANUAL. ALUMINUM Models. 316 S.S. Models NTG40 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 1/14, Rev.

OPERATION MANUAL. ALUMINUM Models. 316 S.S. Models NTG40 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 1/14, Rev. OPERATION MANUAL NTG40 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS ALUMINUM Models 316 S.S. Models A JDA Global Company 1/14, Rev. 3 CAUTION SAFETY POINTS TEMPERATURE LIMITS: Neoprene -17.8 C to

More information

Instrument Valves and Manifolds

Instrument Valves and Manifolds Instrument Valves and Manifolds Needle Valves Instrument Valve Orifice Block Valves Gauge Block Valves Block & Bleed Valves Integral Block & Bleed Valves Two Valve Manifolds Three Valve Manifolds Five

More information

D-040 PN 16 D-040-C PN 16. Combination Air Valve. Description. Applications. Operation. Main Features

D-040 PN 16 D-040-C PN 16. Combination Air Valve. Description. Applications. Operation. Main Features D-00 PN 1 Water Supply D-00-C PN 1 Combination Air Valve EnC-D00WTR-11 Description The D-00 series Combination Air Valve has the features of both an air release valve and an air & vacuum valve. The air

More information

D-040 PN 16 D-040-C PN 16. Combination Air Valve. Description. Applications. Operation. Main Features

D-040 PN 16 D-040-C PN 16. Combination Air Valve. Description. Applications. Operation. Main Features D00.WTR.CAT.ENG0 D-00 PN 1 Water Supply D-00-C PN 1 Combination Air Valve Description The D-00 series Combination Air Valve has the features of both an air release valve and an air & vacuum valve. The

More information

DualSeal 24 Hose System

DualSeal 24 Hose System DualSeal 24 Hose System THE PREFERRED HOSE SYSTEM IDEAL FOR CONNECTING NITROGEN GAS SPRINGS AND ENSURING A BALANCED LOAD METAL FORMING SOLUTIONS DualSeal 24 System The Preferred Hose System IDEAL FOR CONNECTING

More information

CycloBlower Industrial Series. Positive Displacement Blowers & Vacuum Pumps

CycloBlower Industrial Series. Positive Displacement Blowers & Vacuum Pumps CycloBlower Industrial Series Positive Displacement Blowers & Vacuum Pumps 2 50 Years of Proven Results The Gardner Denver CycloBlower Industrial Series offers significant advantages: Efficiency Quality

More information

Technical Data P3 PISTON POWER PUMP NON-ELECTRIC CONDENSATE PUMP SD 9952B

Technical Data P3 PISTON POWER PUMP NON-ELECTRIC CONDENSATE PUMP SD 9952B Technical Data SD 9952B SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NEW YORK, 12586-2035 P3 PISTON POWER PUMP NON-ELECTRIC CONDENSATE PUMP Pressures To 250 PSIG (20.7 barg) Temperatures

More information

Instructions for Installation, Operation, Care and Maintenance

Instructions for Installation, Operation, Care and Maintenance Bulletin 59 Model DDX Deluge Valve (50 mm), ½ (65 mm), (80 mm), 76 mm, 4 (00 mm), 6 (50 mm), 65 mm & 8 (00 mm) Bulletin 59 Instructions for Installation, Operation, Care and Maintenance Wet Pilot Line,

More information

INSTALLATION/OPERATION/MAINTENANCE INSTRUCTIONS FOR ARCHON MODELS WD2010L, WD2010, WD2010H WASHDOWN STATIONS. ARCHON Industries, Inc.

INSTALLATION/OPERATION/MAINTENANCE INSTRUCTIONS FOR ARCHON MODELS WD2010L, WD2010, WD2010H WASHDOWN STATIONS. ARCHON Industries, Inc. ARCHON Industries, Inc. Washdown Stations Models WD2010L, WD2010, WD2010H Installation / Operation / Maintenance Instructions 1 This manual has been prepared as an aid and guide for personnel involved

More information

OPERATING INSTRUCTIONS & SERVICE MANUAL BLUE MAX II HYDROSTATIC TEST PUMP

OPERATING INSTRUCTIONS & SERVICE MANUAL BLUE MAX II HYDROSTATIC TEST PUMP PAGE 1 OF 10 OPERATING INSTRUCTIONS & SERVICE MANUAL BLUE MAX II HYDROSTATIC TEST PUMP EFFICIENT, EASY OPERATION Air operated pump Wide range of pressures and volumes Easy to operate controls Output pressure

More information

75L & 100L JACKETED ASSEMBLY INSTRUCTIONS FOR PROCESS REACTOR SYSTEMS N. Mill Road Vineland, NJ Phone: Fax:

75L & 100L JACKETED ASSEMBLY INSTRUCTIONS FOR PROCESS REACTOR SYSTEMS N. Mill Road Vineland, NJ Phone: Fax: 3800 N. Mill Road Vineland, NJ 08360 Phone: 800.843.1794 Fax: 800.922.4361 ASSEMBLY INSTRUCTIONS FOR 75L & 100L JACKETED PROCESS REACTOR SYSTEMS 1/4 HP Electric Stirrer Motor High Efficiency Condenser

More information

Product Catalog. Fittings ½ AIR PIPE FITTINGS Fitting, 1/2 Air Pipe End Cap Coupler, with Tank Valve

Product Catalog. Fittings ½ AIR PIPE FITTINGS Fitting, 1/2 Air Pipe End Cap Coupler, with Tank Valve To complement our extensive line of cable pressurization products, System Studies also sells a variety of air pipe and pressure tube fittings. This section of the catalog describes these commonly used

More information

The 2600 dewatering pump series. The new force in dewatering

The 2600 dewatering pump series. The new force in dewatering The 26 dewatering pump series The new force in dewatering The new force in dewatering unbeatable in tough environments The 26 series from Flygt represents a major breakthrough in dewatering pump technology.

More information

:,Rhino SD/XD G/D 24 Vdc ISO

:,Rhino SD/XD G/D 24 Vdc ISO :,Rhino SD/XDG/D Vdc ISO ()Rhino SD/XD() SD/XD Rhino SD/XDG/D Vdc ISO Rhino SD/XD, Rhino SD/Xd, (Rhino SD/XD) 006 Nordson Corporation P/N 75606A-0 Rhino SD/XDG/D Vdc ISO 0 9 5 8 7 6 P/N 75606A-0 006 Nordson

More information

Hand Expansion Valves Built Stronger to Last Longer Sizes: 6mm (¼ ) to 305mm (4 )

Hand Expansion Valves Built Stronger to Last Longer Sizes: 6mm (¼ ) to 305mm (4 ) Hand Expansion Valves Built Stronger to Last Longer Sizes: 6mm (¼ ) to 305mm (4 ) Bulletin No. 82-00A Suitable For: Ammonia, Fluorocarbons, Nitrogen and Carbon Dioxide Features ASTM 352 LCB Cast Steel

More information

Mueller Super Centurion 250 Fire Hydrant

Mueller Super Centurion 250 Fire Hydrant Mueller Super Centurion 250 Fire Hydrant Designed for efficient flow and outstanding, long-term reliability Mueller Super Centurion 250 Fire Hydrant...250 psig rating, high flow, dependable performance,

More information

Product Instructions. Mixing Station. Features. Specifications. Materials

Product Instructions. Mixing Station. Features. Specifications. Materials Mixing Station The Viega Mixing Station provides supply water temperature modulation when connected to a variety of heat sources such as conventional or condensing boilers, water heaters, or geothermal

More information

Landfill Gas Well Pump Evaluation Guide

Landfill Gas Well Pump Evaluation Guide Landfill Gas Well Pump Evaluation Guide From Manufacturer of AutoPump Landfill Pumps P/N 2348B Rev. 7-7-10 What to look for in a landfill gas well pump. Standard 5-Year Warranty. Superior Landfill Gas

More information

MCF BALL VALVES OVERVIEW

MCF BALL VALVES OVERVIEW MCF BALL VALVES OVERVIEW ISSUED JULY 2014 MCF BALL VALVES OVERVIEW THE CENTER OF MCF MODULAR THREE-PIECE VALVE CONSTRUCTION, ISO 5211 TYPE BODY CONFIGURATION, ACCOMMODATES A WIDE CHOICE OF SEATS, SEALS,

More information

Delivering Peak Performance. High-pressure liquid and gas flow control solutions for the oil and gas industry s harshest environments

Delivering Peak Performance. High-pressure liquid and gas flow control solutions for the oil and gas industry s harshest environments Delivering Peak Performance High-pressure liquid and gas flow control solutions for the oil and gas industry s harshest environments A leading brand of high pressure valves, tubing, fittings and accessories,

More information

Keystone F89C Pneumatic Quarter-Turn Actuator Chemical Industry / Hazardous area

Keystone F89C Pneumatic Quarter-Turn Actuator Chemical Industry / Hazardous area The F89C addresses the specific requirements for automated quarter-turn valves in the chemical industry on top of the reliability and low maintenance cost offered Features Valve connection compatible with

More information

FORGED HIGH PRESSURE BONNETLESS. ASME CLASSES: Sizes: 1 2 4" ( mm) U.S. Patent # Patented Easy Maintenance!

FORGED HIGH PRESSURE BONNETLESS. ASME CLASSES: Sizes: 1 2 4 ( mm) U.S. Patent # Patented Easy Maintenance! FORGED HIGH PRESSURE BONNETLESS ASME CLASSES: 1690 4500 Sizes: 1 2 4" (15 100 mm) U.S. Patent # 4356832 Patented Easy Maintenance! PROFILE Velan is one of the world's leading manufacturers of industrial

More information

Pressure Independent Control Valve Applications for Building Automation, Temperature Controls, and HVAC Two-Way Chilled Water Hot Water

Pressure Independent Control Valve Applications for Building Automation, Temperature Controls, and HVAC Two-Way Chilled Water Hot Water Rev: 08/19/2013 (ATiMX) Features Pressure Independent Control Valve Applications for Building Automation, Temperature Controls, and HVAC Two-Way Chilled Water Hot Water The Auto Touch Independent Max (ATiMX)

More information

Product Information. Brass Manifolds. Version A

Product Information. Brass Manifolds. Version A Product Information Brass Manifolds Version A Introduction Infloor offers a complete line of brass manifolds for radiant heating applications. This guide explains the how the manifolds work, the setup

More information

ATi Max Series. Pressure Independent Control Valves 2 Way 2-1/2-6

ATi Max Series. Pressure Independent Control Valves 2 Way 2-1/2-6 The Auto Touch Independent Max (ATiMX) valve brings pressure independent control technology to valves up to 6 and flow rates up to 468 GPM. It is a state-of-the-art control valve combining a high quality/

More information

K81-D FIRE HYDRANT GUARDIAN AWWA C502 NSF YEARS. For Generations CERTIFICATIONS ISO 9001 ISO BS OHSAS

K81-D FIRE HYDRANT GUARDIAN AWWA C502 NSF YEARS. For Generations CERTIFICATIONS ISO 9001 ISO BS OHSAS GUARDIAN K81-D FIRE HYDRANT CERTIFICATIONS ISO 9001 ISO 14001 BS OHSAS 18001 AWWA C502 NSF 61 140 YEARS WWW.KENNEDYVALVE.COM C For Generations COMPONENTS AND FEATURES A B C E D F G H J L M K N P Q S R

More information

Lead-free Pneumatic Metering Valve Assemblies (Plastic Bodied) WILLOUGHBY Industries, Inc WEST 78TH STREET / INDIANAPOLIS, IN 46268

Lead-free Pneumatic Metering Valve Assemblies (Plastic Bodied) WILLOUGHBY Industries, Inc WEST 78TH STREET / INDIANAPOLIS, IN 46268 WILLOUGHBY LEAD-FREE VALVE ASSEMBLIES INSTALLATION AND OPERATION MANUAL MODELS: PML and PML Lead-free Pneumatic Metering Valve Assemblies (Plastic Bodied) TABLE OF CONTENTS PRE-INSTALLATION INFORMATION...

More information

Technical Data TYPE A SERIES AIR ADJUSTED PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4011 OPERATING PRINCIPLE

Technical Data TYPE A SERIES AIR ADJUSTED PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4011 OPERATING PRINCIPLE Technical Data SD 4011 SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY 12586-2035 TYPE A SERIES AIR ADJUSTED PILOT PRINTED IN U.S.A. SD 4011/9504 Type A or A83 (wt 6 lb) Type A53 or A 85

More information

Parallel Grippers- DPDS DIRECTCONNECT Modular Series

Parallel Grippers- DPDS DIRECTCONNECT Modular Series Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (8) 426-548 www.cmafh.com 1.134 Parallel Grippers- DPDS DIRECTCONNECT Modular Series Mounting Information: Grippers

More information

DAV - M DAV-M. Air Release and Vacuum Break Valves. Product Catalogue. (Metal Air Valves) DAV-M

DAV - M DAV-M. Air Release and Vacuum Break Valves. Product Catalogue. (Metal Air Valves) DAV-M DAV-M Air Release and Vacuum Break Valves Product Catalogue DAV - M DAV-M (Metal Air Valves) Edition / DAV Series DAV-M General DAV-Metal Air Release and Vacuum Break Valves First Operation: Venting air

More information

ANDERSON GREENWOOD SERIES 500 PILOT OPERATED SAFETY RELIEF VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

ANDERSON GREENWOOD SERIES 500 PILOT OPERATED SAFETY RELIEF VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS Before installation these instructions must be fully read and understood TABLE OF CONTENTS 1. General valve description and start-up... 1 2. Main valve maintenance... 1 3. Pilot maintenance... 5 4. Pilot

More information

PFA LINED BALL VALVES Installation, Operation and Maintenance Manual

PFA LINED BALL VALVES Installation, Operation and Maintenance Manual ACRIS PFA LINED BALL VALVES WWW.AMRESIST.COM Table of Contents Safety Instructions - Definition of Terms............................................2 Introduction..............................................................2

More information

Industrial Turbo Meters, Sizes 2" through 6"

Industrial Turbo Meters, Sizes 2 through 6 Industrial Turbo Meters Sizes 2" through 6" TUR-UM-00530-EN-19 (October 2014) User Manual Industrial Turbo Meters, Sizes 2" through 6" User Manual CONTENTS Scope of the Manual 5 Specifications 5 Product

More information

Transportation Products

Transportation Products Transportation Products Butterfly Valves Hopper Tees Actuators Accessories A Name You ve Trusted for Years... Resilient Seated Butterfly Valves 400 & 480 Series 1 Piece Body Design This economical, resilient

More information

Valves, Fittings, and Manifolds Catalog. We make things MOVE

Valves, Fittings, and Manifolds Catalog. We make things MOVE Valves, Fittings, and Manifolds Catalog We make things MOVE We Make Things Move A forward-thinking innovator, Bimba provides industry-leading pneumatic, hydraulic and electric motion solutions that are

More information

PRODUCT OVERVIEW. Our BDB (Bolted Body) and BW3 (Fully Welded Body) trunnion-mounted ball valves are designed and manufactured

PRODUCT OVERVIEW. Our BDB (Bolted Body) and BW3 (Fully Welded Body) trunnion-mounted ball valves are designed and manufactured PRODUCT OVERVIEW For over 30 years, FluoroSeal has been manufacturing and customizing a wide range of valves, and accessories for many industries including Oil & Gas, Petrochemical, Chemical, Mining, Pharmaceutical,

More information

QA4 / QA6 / QA8 Series Precision Air Nutrunners

QA4 / QA6 / QA8 Series Precision Air Nutrunners QA4 / QA6 / QA8 Series Precision Air Nutrunners Because every assembly is critical There s much more to an assembly application than merely putting wrench to bolt. It s an intricate matter of linking tool

More information

DSP SERIES. Oil Free Rotary Screw Air Compressors hp kw

DSP SERIES. Oil Free Rotary Screw Air Compressors hp kw DSP SERIES Oil Free Rotary Screw Air Compressors 30 300 hp 22 240 kw Sullair and Hitachi When Sullair became A Hitachi Group Company in July, 2017 two compressor titans joined forces bringing customers

More information

Submersible heavy-duty pumps for construction, tunneling, mining, quarries and other demanding industries

Submersible heavy-duty pumps for construction, tunneling, mining, quarries and other demanding industries Submersible heavyduty pumps for construction, tunneling, mining, quarries and other demanding industries Drainage pumps Mini Minex Minette Minor Major Master Matador Maxi Magnum Mega Sludge pumps Solid

More information

This innovation places FluoroSeal Plug Valves at the leading edge of technology in the industrial valve market.

This innovation places FluoroSeal Plug Valves at the leading edge of technology in the industrial valve market. Specialty Valves EZ-SEAL TOP SEAL & ADJUSTMENT SYSTEM This product is available on FluoroSeal Sleeved and Lined Plug Valves in ANSI/ ASME and DIN standards. In fact all DIN valves up to DN 150 come fitted

More information

Disc Valve Hydraulic Motors 2000 Series

Disc Valve Hydraulic Motors 2000 Series Disc Valve Hydraulic Motors 10.2014 inspired hydraulics. Änderungen und Druckfehler vorbehalten 10.2014 EN EATON_Motoren english Highlights Port A Features Three zone design for longer life and true bi-directionality.

More information

DIESEL SEALING SOLUTIONS

DIESEL SEALING SOLUTIONS DIESEL SEALING SOLUTIONS FREUDENBERG DIESEL SEALING SOLUTIONS The Freudenberg product range offers more than 16,000 standard products and a multitude of customer-specific solutions, with outstanding seals

More information

Trelleborg provides solutions for:

Trelleborg provides solutions for: Trelleborg provides solutions for: Vehicle Type Product Range Wheel ers Solid: Brawler HPS Press-On & Brawler HD Mold-On Pneumatic: E3/L3 & L2 Pneumatic: G2 & L2 Motor Graders Skid Steer ers Solid: Brawler

More information

A Type Double Acting Actuator Type: PA2911

A Type Double Acting Actuator Type: PA2911 Type: PA2911 Actuator fitted via mounting kit Pneumatic Actuator features: Rack and pinion construction Hard anodised extruded aluminium body Epoxy coated cast aluminium end caps Pre-tensioned spring sets,

More information

Hydraulic Master Cylinders

Hydraulic Master Cylinders Hydraulic Master Cylinders flange mount and side mount, straight-bore and two-stage cylinders Hydraulic Cylinders for Mobile and Industrial Applications Why choose MICO? MICO, Incorporated designs, manufactures

More information

CycloBlower XP Series offers 20 psig continuous pressure and 17 "Hg continuous vacuum.

CycloBlower XP Series offers 20 psig continuous pressure and 17 Hg continuous vacuum. Model 5CDL13 Model 7CDL17 Model 11CDL31 CycloBlower XP Series offers 20 psig continuous pressure and 17 "Hg continuous vacuum. Clean Air/Gas Delivery Since the rotors do not touch each other or the housing,

More information

APCO SLANTING DISC CHECK VALVES

APCO SLANTING DISC CHECK VALVES BULLETIN 800 JULY 2011 APCO SLANTING DISC CHECK VALVES Series 800, 800B, 800T APCO Slanting Disc Check Valve With decades of experience to guarantee reliability and outstanding performance, our Slanting

More information

Roth NP Manifold System Installation Instructions

Roth NP Manifold System Installation Instructions Roth Industries, Inc. 268 Bellew Avenue South Watertown, NY 360 Ph. 35-755-0 Fax 35-475-0200 www.roth-usa.com info@roth-usa.com ) Product description Constructed of heavy wall extruded nickel plated brass

More information

HYDRAULIC VARIABLE PUMPS

HYDRAULIC VARIABLE PUMPS HYDRAULIC VARIABLE S EFFICIENT VARIABLE DELIVERY Checkball pump delivery is controlled by variable inlet ports in each piston pumping chamber. In these hydraulic variable models, output is regulated by

More information

ALTITUDE CONTROL VALVES FOR ONE WAY FLOW

ALTITUDE CONTROL VALVES FOR ONE WAY FLOW PROJECT NAME LOCATION ALTITUDE CONTROL VALVES FOR ONE WAY FLOW INTRODUCTION This specification covers the design, manufacture, and testing of 2 in. (50 mm) through 36 in. (900 mm) Control Valves PART 1

More information

Description. Rhino SD2/XD2 Type-H Control Modules. S 55-Gallon Drum with Pneumatic Changeover S 55-Gallon Drum with Electric Changeover

Description. Rhino SD2/XD2 Type-H Control Modules. S 55-Gallon Drum with Pneumatic Changeover S 55-Gallon Drum with Electric Changeover Description NOTE: Throughout this document, the Rhino SD2/XD2 Type-H Control Modules are referred to as the Control Module. See Figure 1. The Control Module (1) provides the pneumatic operating functions

More information

Ram Cushions and Pressure Parallels Dynamic Solutions For A Global Market

Ram Cushions and Pressure Parallels Dynamic Solutions For A Global Market Nitro-Dyne Ram Cushions and Pressure Parallels APPROVED 97/23/EC Dynamic Solutions For A Global Market Nitro-Dyne Ram Cushions and Pressure Parallels Table of Contents Page Introduction...2 The Advantages...3

More information

K81-DD FIRE HYDRANT GUARDIAN AWWA C502 NSF YEARS. For Generations CERTIFICATIONS ISO 9001 ISO BS OHSAS

K81-DD FIRE HYDRANT GUARDIAN AWWA C502 NSF YEARS. For Generations CERTIFICATIONS ISO 9001 ISO BS OHSAS GUARDIAN K81-DD FIRE HYDRANT CERTIFICATIONS ISO 9001 ISO 14001 BS OHSAS 18001 AWWA C502 NSF 61 140 YEARS WWW.KENNEDYVALVE.COM C For Generations COMPONENTS AND FEATURES A B C E D F G H J K M L N P Q S R

More information

OPERATOR S MANUAL INCLUDING: OPERATION, INSTALLATION & MAINTENANCE RELEASED:

OPERATOR S MANUAL INCLUDING: OPERATION, INSTALLATION & MAINTENANCE RELEASED: OPERATOR S MANUAL 670042 INCLUDING: OPERATION, INSTALLATION & MAINTENANCE RELEASED: 1-25-07 REVISED: 8-27-08 (REV. 02) 1/2" DIAPHRAGM PUMP U.L. LISTED, 1:1 RATIO (METALLIC) READ THIS MANUAL CAREFULLY BEFORE

More information

Anderson Greenwood Series 5100 Pilot Operated Pressure Relief Valves

Anderson Greenwood Series 5100 Pilot Operated Pressure Relief Valves ANDERSON GREENWOOD Series 5100 Modulating Safety Relief Valve Anderson Greenwood has developed the revolutionary Series 5100 specifically to serve Economizer applications requiring pressure relief under

More information

Eclipse GEN 2.0 CAFSystem, Model 150-ECL CAFS PTO Kit Installation Instructions

Eclipse GEN 2.0 CAFSystem, Model 150-ECL CAFS PTO Kit Installation Instructions Eclipse GEN 2.0 CAFSystem, Model 150-ECL CAFS PTO Kit Installation Instructions Read Read through the the safety installation information instructions overhaul carefully instructions before carefully beginning

More information

Installation Instructions

Installation Instructions Installation Instructions MANUAL FLUSH VALVE,. GPF Exposed Flushometer for /" top spud Urinals Certified to comply with: ASSE 07 ANSI/ASME A.9. ADA Compliant 0 AS America, Inc. M9600 Rev.. MODEL NUMBERS

More information

Pneumatic Products st»

Pneumatic Products st» » Pneumatic Products » Industry Standouts for Over 50 Years The benefits of an innovative, pneumatic coupling design were solid enough to single-handedly launch CEJN in 1955. This reliable, easy-to-handle

More information

HALLMARK INDUSTRIES INC

HALLMARK INDUSTRIES INC Performance Part No. HP. CONVERTIBLE JET PUMP USER S MANUAL GPH of Water @ Total Discharge Pressure of 40 psi Max. Pressure Max suction (shallow well) Max Suction (deep well) Max GPM (@0 head) Max Discharge

More information

Industry Standouts for Over 50 Years

Industry Standouts for Over 50 Years » Pneumatic Products » Industry Standouts for Over 50 Years The benefits of an innovative, pneumatic coupling design were solid enough to single-handedly launch CEJN in 1955. This reliable, easy-to-handle

More information

ENDURO TEMPEST CT SERIES

ENDURO TEMPEST CT SERIES ENDURO TEMPEST CT SERIES ENDURO THE WORLD STANDARD FOR ENDURANCE AND EFFICIENCY T he number one air end Gardner Denver s ENDURO air end has set new standards for air end endurance and efficiency. The world

More information

MODULATING FLOAT CONTROL VALVE

MODULATING FLOAT CONTROL VALVE PROJECT NAME LOCATION MODULATING FLOAT CONTROL VALVE INTRODUCTION This specification covers the design, manufacture, and testing of 2 in. (50 mm) through 36 in. (900 mm) Control Valves PART 1 - GENERAL

More information

New Way Porous Gas Bearings as Seals. Bearings Seals

New Way Porous Gas Bearings as Seals. Bearings Seals New Way Porous Gas Bearings as Seals Bearings Seals New Way Overview TM Founded January 1994. Aston, Pa. 15 miles south of Philadelphia 54 employees 35,000 sq ft facility, Environmentally Controlled Precision

More information

Highly Engineered, Quality Locomotive Products. Ingenuity in Motion

Highly Engineered, Quality Locomotive Products. Ingenuity in Motion Highly Engineered, Quality Locomotive Products Ingenuity in Motion World Class Manufacturing WABCO Locomotive Products designs and manufactures highly engineered pneumatic components and related products.

More information

Refinery Supply Company, Inc.

Refinery Supply Company, Inc. Refinery Supply Company, Inc. OPERATING INSTRUCTIONS Super Pressure Dead Weight Tester Catalog No. 35260 Serving the Oil & Gas Industry since 1923 9133-A East 46th Street Tulsa, Oklahoma 74145-4823 Voice

More information

Patent Pending EXTENDED-DUTY PISTON PUMP

Patent Pending EXTENDED-DUTY PISTON PUMP TM Patent Pending EXTENDED-DUTY PISTON PUMP O p e r a t i o n & I n s t a l l a t i o n M a n u a l P/N 95222 Rev. 9-29-9 4 2 6 psi 9 1 12 16 14 2 4 6 8 1 INCHES W.C. 4 2 6 N psi IN 1 12 16 14 EXTENDED-DUTY

More information

IFOA Integral Flow Orifice Assembly

IFOA Integral Flow Orifice Assembly Instruction MI 022-333 July 2007 Introduction IFOA Integral Flow Orifice Assembly The IFOA integral flow orifice assembly is used in conjunction with a Foxboro electronic or pneumatic differential pressure

More information

FLOAT CONTROL VALVES

FLOAT CONTROL VALVES PROJECT NAME LOCATION FLOAT CONTROL VALVES INTRODUCTION This specification covers the design, manufacture, and testing of 8 in. (200 mm) through 36 in. (900 mm) Control Valves PART 1 - GENERAL 1. Standard

More information

Series 50 Full Port Flanged Ball Valves

Series 50 Full Port Flanged Ball Valves USA 800-766-0076 Fax 33-890-4456 www.smithcooper.com www.sharpevalves.com Los Angeles, CA Chicago, IL Atlanta, GA Vancouver, WA Houston, TX Design Features ASME B6.34 Design Full port, split body design

More information

20 Series. Simplify your pumping needs. s Adhesive Supply Servo Pump:

20 Series. Simplify your pumping needs. s Adhesive Supply Servo Pump: 20 Series Model 20-02-06 Adhesive Supply Servo Pump Simplify your pumping needs. s Model 20-02-06 Adhesive Supply Servo Pump allows excessive adhesive pressure to self-release back into the pump on shutdown

More information

Series 11 Miniature Pneumatic Solenoid Valve 15mm Solenoid Valve

Series 11 Miniature Pneumatic Solenoid Valve 15mm Solenoid Valve Series 11 Miniature Pneumatic Solenoid Valve 15mm Solenoid Valve Typical Applications Oxygen Conservers Oxygen Concentrators Compression Therapy Gas Chromatography Insufflators Medical & Analytical Gas

More information

R10 & R10 Turbo. The R10 and R10 Turbo are part of the Nelson Rotator family of sprinklers. R10-11 U.S. & METRIC

R10 & R10 Turbo. The R10 and R10 Turbo are part of the Nelson Rotator family of sprinklers. R10-11 U.S. & METRIC R10 & R10 Turbo R10-11 U.S. & METRIC R5 R10 R10 Turbo R2000 R2000LP/WF 9-29 GPH 0.3-0.7 GPM 0.6-2.1 GPM 0.7-3.5 GPM 0.9-5.7 GPM 34-110 LPH 61-164 LPH 140-469 LPH 150-792 LPH 191-1295 LPH The R10 and R10

More information

Installation, Operation and Maintenance Manual. TOM WHEATLEY Piston Check Valve TOM WHEATLEY

Installation, Operation and Maintenance Manual. TOM WHEATLEY Piston Check Valve TOM WHEATLEY TOM WHEATLEY Piston Check Valve TOM WHEATLEY 03/2011 / IOM-TOM-PCV-01 2 TABLE OF CONTENTS TOM WHEATLEY PISTON CHECK VALVE Description.... 4 Installation and Operation.... 5 Horizontal Installation....

More information

Air Operated 3 Way Stainless Steel Ball Valve

Air Operated 3 Way Stainless Steel Ball Valve Available with actuator function: DOUBLE ACTING, SINGLE ACTING (Failsafe), MODULATING (with optional positioner) Type: 2300R Type: 2310R Type: 2320R Pneumatic actuator direct mounted Actuator fitted via

More information

Abrasive Blast Nozzles

Abrasive Blast Nozzles Abrasive Blast Nozzles A Guide to Blasting Nozzle Selection Choosing the right blast nozzle for each application is simply a matter of understanding the variables that affect cleaning, performance and

More information

Cartridges & Manifolds

Cartridges & Manifolds Cartridges & Manifolds SAE Encapsulated Cartridge Meets Performance Requirements of D.O.T. FMVSS 571.106 Meets Dimensional Standards of SAE 2494-4 in 6061-T6 Aluminum Eliminate the space and labor costs

More information

Please note this is a condensed catalog. For a complete version, contact Velan directly.

Please note this is a condensed catalog. For a complete version, contact Velan directly. Please note this is a condensed catalog. For a complete version, contact Velan directly. VELAN VALVES IN POWER With an installed base covering over 300 nuclear power plants and over 2,000 thermal power

More information

3/4" DIAPHRAGM PUMP 1:1 RATIO (NON-METALLIC) READ THIS MANUAL CAREFULLY BEFORE INSTALLING, OPERATING OR SERVICING THIS EQUIPMENT.

3/4 DIAPHRAGM PUMP 1:1 RATIO (NON-METALLIC) READ THIS MANUAL CAREFULLY BEFORE INSTALLING, OPERATING OR SERVICING THIS EQUIPMENT. OPERATOR S MANUAL PD07P-X-X INCLUDING: OPERATION, INSTALLATION & MAINTENANCE RELEASED: 11-30-06 REVISED: (REV. 01) 3/4" DIAPHRAGM PUMP 1:1 RATIO (NON-METALLIC) READ THIS MANUAL CAREFULLY BEFORE INSTALLING,

More information

RACK & PINION ACTUATORS 2R40 to 2R1750 Series Installation & Maintenance Manual

RACK & PINION ACTUATORS 2R40 to 2R1750 Series Installation & Maintenance Manual TRIAC 2R Series Actuators: Attention: Instructional videos on some of the information provided below can be found on our website (http://www.a-tcontrols.com/videos/). Description Section Installation of

More information

Standard Port, Uni-Body Flanged Ball Valves

Standard Port, Uni-Body Flanged Ball Valves USA 800-766-0076 Fax 323-890-4456 www.smithcooper.com www.sharpevalves.com Los Angeles, CA Chicago, IL Atlanta, GA Vancouver, WA Houston, TX Design Features ASME B6.34 Design Standard port, Uni-body design

More information

MEASUREMENT SOLUTIONS FOR THE WATER & WASTEWATER INDUSTRY

MEASUREMENT SOLUTIONS FOR THE WATER & WASTEWATER INDUSTRY MEASUREMENT SOLUTIONS FOR THE WATER & WASTEWATER INDUSTRY MUNICIPAL AND INDUSTRIAL WATER & WASTEWATER PROCESSING NOSHOK provides pressure, level and temperature measurement solutions, along with diaphragm

More information

R-Series Rod Model RS. Data Sheet. Model RS Rod-style sensor with IP68/IP69K Super Shield Housing. Interrogation Return wire.

R-Series Rod Model RS. Data Sheet. Model RS Rod-style sensor with IP68/IP69K Super Shield Housing. Interrogation Return wire. Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors R-Series Rod Model RS SENSORS Document Part Number 551251 Revision A Data Sheet Model RS Rod-style sensor with IP68/IP69K Super

More information

CRYOGENIC. Italian Manufactured, Italian Quality

CRYOGENIC. Italian Manufactured, Italian Quality Italian Manufactured, Italian Quality CRYOGENIC Via Di Vittorio 307/25-20099 Sesto San Giovanni (MI) - Italy Tel: +39.028.976.1628 - Fax: +39.028.976.2167 www.sestovalves.com - sales@sestovalves.com Introduction

More information

TYPE E Main Valve Sizes 3 /8 through 12

TYPE E Main Valve Sizes 3 /8 through 12 Technical Data SD 3001E PRINTED IN U.S.A. SD 3001E/9709 SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY 12586-2035 A B TYPE E MAIN VALVE FACE TO FACE DIMENSIONS C D E DIMENSIONS (inches)

More information

Helping you get the job done right the first time! Dependable Lightweight- Easy to use 12 volt Groundwater pumps.

Helping you get the job done right the first time! Dependable Lightweight- Easy to use 12 volt Groundwater pumps. Helping you get the job done right the first time! Dependable Lightweight- Easy to use 12 volt Groundwater pumps. Building on over 18 years in business, Proactive Environmental Products understands your

More information