Troubleshooting and Maintenance of Air-Powered Pumping Systems
|
|
- Imogen Deirdre Osborne
- 5 years ago
- Views:
Transcription
1 Troubleshooting and Maintenance of Air-Powered Pumping Systems David Kaminski QED Environmental Systems Inc. Ann Arbor, MI / San Leandro, CA Copyright QED Environmental Systems, Inc. 2015; all rights reserved. The information contained within this document may not be published, broadcast, rewritten or otherwise distributed without prior written authorization from QED. Today s Webinar Topics Air-powered pump system components Principles of operation how it works Diagnosing the problem: Look and Listen Common operational issues Safety considerations during pump maintenance Tips on pump removal and installation Pump disassembly tools and tips Cleaning frequency and service life expectations Spare parts and spare pumps save time and $$$ Accessories for improving pump performance 1
2 2 QED AutoPump AP4+ Pump Components Discharge Head & Air Valve Assemblies Discharge Tube/Float Guide Pump Body (Casing) Float Assembly with Guide Plates Actuator Rod Inlet Valve Assembly and Inlet Screen Air-powered automatic pump: How it works Discharge Cycle When float reaches the top of its travel, exhaust valve closes and air inlet valve opens Air pressure against liquid closes inlet check valve and pushes liquid up discharge tube As liquid level drops, float follows and pulls actuator rod down, closing the air inlet valve and opening exhaust valve to repeat Fill Cycle Fill Cycle Hydrostatic pressure opens inlet check valve As pump fills with liquid, air escapes through exhaust valve and internal float rises
3 Normal Pump Operating Characteristics 1. Cycling you should hear a release of air pressure when the pump is cycling (exhaust cycle). 2. Pressure gauge if there is a filter/regulator at the well head, you can see a slight drop in the air pressure (5-10 PSI) with each pump discharge cycle 3. Cycle counter the cycle counter should advance a half count in the discharge cycle, then advance a full count with an audible click during the exhaust cycle What if my pump isn t cycling? Determine if the issue is the operating conditions in the well or a pump malfunction Examples of operating conditions: Very low well yield (will eventually cycle check counter) Liquid level has dropped below actuation point Air supply pressure insufficient for discharge Excessive discharge line back pressure Examples of pump malfunction Float sticking due to solids buildup, slime, silt Check valve not working due to debris, sand Air valve mechanism plugged or out of adjustment 3
4 First Step: Look and Listen Look at the well head and connections for an obvious problem broken fittings or loose connections, tubing kinks, etc. Listen for an air leak from a fitting or line at the well head Look at the air pressure gauge for low or no pressure Listen for a continuous discharge condition you ll hear a hissing sound coming from the pump exhaust line (may be above or below well cap) and/or the liquid discharge line Pump stuck in discharge mode Continuous air from the exhaust line can indicate that the pump is stuck in discharge mode or in crossover between pump cycles The float may be stuck due to buildup on the discharge tube or debris inside the pump Cleaning will usually resolve the problem, but may require air valve adjustment 4
5 Pump stuck between cycles If the pump is stuck between cycles, both the air inlet and exhaust poppet valve will be open, allowing air to pass continuously out of the exhaust port and possibly through the discharge line Additional evidence: the cycle counter may be stuck between cycle counts Possible causes include an air valve mechanism that is worn or out of adjustment, a worn pivot pin or worn air valve lever half bushing Cleaning, adjustment or repair may be required to resolve the problem Is liquid level above actuation point? To determine if you have sufficient liquid over the pump to actuate the air valve, you need to know: The installed depth of the pump The pump model and its actuation point The liquid level in the well/riser If the liquid level is above the actuation point and there is sufficient air pressure but the pump isn t cycling, there may be a problem with the pump, such as a stuck float, debris, actuator rod hang-up, air valve issue, etc. 5
6 6 Pump Actuation Point The point at which the liquid level inside the pump activates the air valve mechanism is called the actuation point The actuation point is the distance from the bottom of the pump to the top of the float travel (top of inlet on top-fill pumps) This distance varies based on pump body length, float length and inlet position and is specified for each pump model The pump position in the well determines the maximum drawdown level in the well How vacuum affects the pump actuation point A vacuum applied to the well (e.g., landfill gas collection, vapor extraction) will RAISE the actuation point above the design point when the pump exhaust is outside the well The increase in the actuation point is based on the amount of vacuum applied to the well, measured in inches (centimeters) of water column (WC) In the example, a vacuum of 20 (51 cm) WC raises the actuation point of the pump from 33 (84 cm) to 53 (135 cm)
7 How to check if vacuum is preventing the pump from cycling 1. Install a level tape in the well or activate your dedicated level measurement system 2. Turn off and release vacuum at the well cap/flange 3. Measure/watch the liquid level and wait for it to begin dropping 4. If the pump starts cycling at the design actuation point, the problem is insufficient submergence under vacuum. Possible solutions: Lower the pump in the well/riser if possible Use a shorter pump model with a lower actuation point If air exhaust is outside the well, change to inside well or install an equalization valve to reference exhaust to vacuum Pump not cycling - insufficient air pressure at the well head A pump may not cycle if the air pressure is too low to lift the liquid to the well head and/or overcome header line back pressure Air-powered pumps need a minimum of 0.5 PSI air pressure for every foot of lift desired plus 1.0 PSI for every PSI of back pressure in the header line Test for low air pressure: increase pressure at well head in 5 PSI increments; pump will start cycling if pressure was too low to overcome lift requirement Test for high header line back pressure: turn off air, disconnect discharge line at header and direct it back into well; pump will start cycling if pressure was too low to overcome header back pressure 7
8 How to jump start your pump Sometimes a quick jump start can get the pump cycling again when it stalls or is stuck in discharge Remove the air line from the filter/regulator, allow all the air to exhaust from the pump, then reconnect the air line; pump should cycle if sufficiently submerged Another jump start is to unbolt the well cap and shake the pump/tubing to dislodge the float If the jump start method gets the pump cycling again, it s a good indication that the pump needs to be cleaned, serviced or adjusted to maintain consistent operation and maximum performance Air Valve Mechanism Adjustment The air valve mechanism should not require adjustment unless it has been repaired or has some wear from long-term use If adjustment is necessary, contact QED for information and instructions based on pump model Air Valve Out of Adjustment (Gap between valve mechanism and pump head) After Proper Air Valve Adjustment 8
9 Pump maintenance safety considerations Most important make sure the pump and all lines are not pressurized before you begin any disassembly! Wear appropriate safety gear Safety glasses with side shields or a full face shield Protective outer clothing (e.g. Tyvek jump suit) Chemically resistant gloves taped at top to prevent leaks Reflective high-visibility vest or coat Hard hat Shut-offs, check valves and lines Shut off any valves air supply, discharge header Release all the air pressure from the pump If the pump discharge tubing is filled with liquid, you can lighten your load using the QED Pump Blow-Out Kit (Part Number shown here) to empty the lines 9
10 Lifting the pump and tubing Wear protective gloves and get a good grip on the tubing or hoses Try to avoid getting kinks in tubing kinks tend to be permanent and can restrict flow or create leaks Use your legs, NOT YOUR BACK! Use a step ladder or tailgate to gain some height and leverage If the system is too heavy, use a winch or crane Well head tubing rollers If possible, use a well head tubing roller mounted to the edge of the well casing or flange to simplify pump removal and avoid tubing kinks Pull the tubing into the roller and walk it out of the well less stress on legs, back and shoulders 10
11 Well head tubing rollers Tubing roller mounted on flange Tubing roller mounted on well casing Keeping debris out of air lines Debris in air lines (dirt, insects, etc.) can clog filter regulators and plug pump air valve poppets Blow out air header lines before connecting pump air supply hoses Cap or tape end of tubing after pulling the pump to avoid debris 11
12 Cleaning air-powered pumps Determining cleaning frequency Cleaning frequency is determined on a site-by-site basis - some sites may go a year or more without cleaning while others may require cleaning as often as monthly or more where high solids or sticky deposits occur If no site history, pull new pumps after 1-3 months of use to gauge need for cleaning or wait for indication of stalling Planned maintenance can be more cost effective than responding to pumps that shut down when dirty 12
13 13 AutoPump *AP4+ Designed for easier cleaning Easier disassembly: removing four bolts on bottom inlet allows complete pump disassembly in minutes no turning of the inlet assembly or O-ring hang-up/dragging Easier service: quick-release clip on actuator rod allows quick float removal for easier cleaning. Pump body has a high-polish ID finish to reduce solids build-up and precision bore sizing to improve O-ring fit Increased durability: All metal parts are 304SS or higher for improved corrosion resistance; plastic parts are high-strength & hightemperature engineering plastics (PVDF, PEEK) Increased warranty: 5-year full warranty with no pro-rating in later years * Patent Pending AutoPump AP4+ Design Features New Air Valve Mechanism Design The new captured pin design eliminates need for fasteners, clips or cotter pins at valve stem Improved reliability, easier to service exhaust seat is easier to adjust Now on all AP4+ models!
14 14 Introducing the first low-maintenance air-powered pump: The Ultra lasts up to 10 times longer between service events and requires 50% less time to clean The Ultra combines all of the design features and rugged reliability of the AutoPump AP4+ in an innovative design that reduces build-up of solids and sticky deposits on the float and center rod Greater reliability in challenging applications Fewer pump pulls for maintenance Cleaning is faster and easier Design Features Non-stick float and electro-polished center rod reduce solids buildup, low-friction engineered plastic guide plates reduce pump stalling All metallic parts are 316-grade SS for greater corrosion resistance and reliability Non-stick, high polish finishes make cleaning easier can be as easy as wipe and rinse
15 15 Field testers compared the new AutoPump Ultra to existing pumps and reported the following results: Maximum uptime Minimum Downtime Teardown and cleaning took absolutely no effort No soaking required Only needed a water spray to clean Removed residue with some clean water and the swipe of a hand Easier to clean by 50% It s been running for four months and I haven t had to clean it yet! Annual Pump Cleaning Savings with AutoPump Ultra Standard Pump AutoPump Ultra Cleaning Frequency Pump Pulls/Year AP Ultra Frequency Pump Pulls/Year Annual Pulls Saved $50/pull $100/pull $150/pull 4 weeks weeks < 3 10 $ 500 $ 1,000 $ 1,500 1 week weeks < 3 17 $ 850 $ 1,700 $ 2,550 2 weeks 26 8 weeks < 7 19 $ 950 $ 1,900 $ 2,850 2 weeks weeks < 3 23 $ 1,150 $ 2,300 $ 3,450 1 week weeks < 3 49 $ 2,450 $ 4,900 $ 7,350 Reducing cleaning frequency with the AutoPump Ultra by as little as 50% at an average cleaning frequency of every 4 weeks can save from $325 to $975 on an annual basis!
16 Getting the right tools QED offers a complete tool kit for AP4 pumps Double pin spanner to remove threaded inlet Honing tool to remove hard deposits from pump body Casing removal tool, punch and Allen wrench Optional pipe vise with rubber jaws to hold pump body What about tools for the AP4 Plus? The newly redesigned AP4+ has a bottom inlet design that comes off easily by removing three small bolts no need for the spanner or casing tool! The honing tool and pipe vise (if desired) can be purchased separately AP4 Service Tool Kit with optional Pipe Vise 16
17 Cleaning agents and supplies Degreasing agents such as Simple Green or Detergent 8 can remove oily or slimy deposits Scouring pads can remove about 90% of bio-growth and buildup on pump parts Use brush kits with extended handle to clean inside the pump body and discharge tube Cleaning agents for scale buildup Cleaning solutions such as CLR or common acids such as citric acid and vinegar (acetic acid) can help remove heavy mineral deposits and biorock avoid hydrochloric or sulfuric acids Do not leave metal parts in strong acids overnight! Don t clean acetal (Delrin ) plastic parts with acids it can weaken/damage them NEVER mix acids with other cleaning solutions ALWAYS rinse other cleaners away first to avoid dangerous (and potentially fatal) chemical fumes 17
18 Spare parts for field repairs Spare parts needed will vary by pump model, but most require only a handful of parts The quantity of spare parts you will need is dependent on the size of your site and how many pumps you have QED Customer Service can help you with recommended parts for your pumps, such as check balls, O-rings, fittings and springs Spare pumps = major cost savings When field labor for cleaning or repairs exceeds minutes, having one or more spare pumps can save considerable cost over immediate field repair Less downtime, especially valuable in LFG wells Maintenance can be done in the shop or by the manufacturer rather than under field conditions No need to stock every necessary spare parts Shipping for parts or pump repairs can be done at economy rates rather than overnight shipping 18
19 19 Accessories to improve performance and reduce maintenance in tough applications Silt and Foam Filter Designed to reduce solids loading in pumps to improve performance and extend maintenance intervals Threads into pump inlet assembly (replaces standard inlet screen) Filter pad material can be cleaned or replaced Can also improve pump performance and reduce leachate emitting from external exhaust line in wells with foaming leachate Accessories to improve performance and reduce maintenance in tough applications Wide Slotted Float Can improve performance in wells with silt or where solids deposit on pump components Actuator rod slot is wider for greater clearance between rod and float Now standard on AP4+ and AP Ultra models Can be retrofit to existing AP4+ pumps (contact QED Customer Service for details) Standard Float Wide Slot Float
20 Accessories to improve performance and reduce maintenance in tough applications Wide-Slot Float with Non-Stick Coating Entire float assembly is coated with a proprietary non-stick coating Greatly reduces build-up of solids on the float, which can extend maintenance intervals Speeds cleaning and reduces chance of damaging float during cleaning Replaces Teflon-wrapped floats for applications with sticky deposits or high dissolved solids Can be retrofit to existing AP4+ pumps contact QED for details Stand tubes for pump testing A stand tube should be used to verify that a pump is working before you send it back down the well to avoid pulling it again if it s still not working You can make a stand tube from a piece of 4-inch diameter PVC pipe or well casing about 5 feet long, with a flat threaded cap or plug at the bottom PVC is very inexpensive, holds up well to most cleaning solutions and leachates A stand tube can save HOURS of lost time if you find that a pump isn t working properly before it s installed 20
21 Pump service life expectations Pump service life is dependent on operating conditions of each well (chemistry, temperature, solids, etc.) and proper materials selection for the application The biggest factor you can control is pump maintenance. Many QED pumps have been in use for years and are still operational due to regular maintenance 90% of all pump maintenance is cleaning, not repairs We are confident that the new AutoPump Ultra 4.0 will prove to be a winner at your site QED will send you a new Ultra pump for evaluation in your most challenging well or sump After trial period, QED will invoice you for the pump, or just return it with no obligation to buy Contact QED at or Info@qedenv.com for more information on the Try & Buy program 21
22 22 Some applications are a bit more challenging than others, but with proper selection of pump model and materials, good installation practices and adequate preventative maintenance, air-powered automatic pumps can handle some of the toughest pumping application seen at landfill and remediation sites with longer service life than other pump designs. Questions? David Kaminski QED Environmental Systems, Inc. info@qedenv.com Toll-Free Numbers Ann Arbor, MI: San Leandro, CA: Website
Troubleshooting and Maintenance of Air-Powered Pumping Systems
Troubleshooting and Maintenance of Air-Powered Pumping Systems David Kaminski QED Environmental Systems Inc. Ann Arbor, MI / San Leandro, CA Copyright QED Environmental Systems, Inc. 2013-2017; all rights
More informationTroubleshooting and Maintenance of Air-Powered Pumping Systems
Troubleshooting and Maintenance of Air-Powered Pumping Systems David Kaminski QED Environmental Systems Inc. Ann Arbor, MI / San Leandro, CA Copyright QED Environmental Systems, Inc. 2013; all rights reserved.
More informationInnovative Wellhead Products for Landfill Gas Management
Innovative Wellhead Products for Landfill Gas Management QED Environmental Systems Inc. Ann Arbor, Michigan - San Leandro, California Copyright QED Environmental Systems, Inc. 2013; all rights reserved.
More informationLandfill Gas Well Pump Evaluation Guide
Landfill Gas Well Pump Evaluation Guide From Manufacturer of AutoPump Landfill Pumps P/N 2348B Rev. 7-7-10 What to look for in a landfill gas well pump. Standard 5-Year Warranty. Superior Landfill Gas
More informationInjector. General Information CAUTION. Use only the specified injector for the engine.
Page 1 of 32 006-026 Injector General Information CAUTION Use only the specified injector for the engine. All engines use closed nozzle, hole-type injectors. However, the injectors can have different part
More informationSample Pro 3/4" Portable MicroPurge Pump. User's Guide P/N REV The World Leader in Air Powered Pumps
PATENT PENDING Pro 3/4" Portable MicroPurge Pump User's Guide P/N 959 REV. -8-03 The World Leader in Air Powered For Remediation, Landfills and Ground Water Sampling Ground water Sampling Remediation,
More information3M Overhaul Service Kit
SERVICE INSTRUCTIONS FOR 3M 12,000 RPM 3 in. (77 mm) RANDOM ORBITAL SANDERS 3M Overhaul Service Kit The part number 20346, 3M Overhaul Service Kit, contains all the replacement parts that naturally wear
More informationBackpack Sprayer. Use and Care Manual
Backpack Sprayer Use and Care Manual BACKPACK SPRAYER CAUTION: Read and follow all instructions Do Not Return This Backpack To The Store For Help, Information or Parts, Call : 1-800-311-9903 The Fountainhead
More information3M Overhaul Service Kit
SERVICE INSTRUCTIONS FOR 3M 12,000 RPM 5 in. (127 mm) and 6 in. (150 mm) RANDOM ORBITAL SANDERS 3M Overhaul Service Kit The part number 20347, 3M Overhaul Service Kit, contains all the replacement parts
More informationOil Drain Plug Repair Kit. 5. Boring tool (drill bit) 1. Oil cap with regulator. 6. Alignment tool. 2.
Oil Drain Plug Repair Kit Part #: AGA-ODP-12-14-K 1. Oil cap with regulator 2. Oil drain plugs 3. Air supply hose with valve 4. Debris shield 5. Boring tool (drill bit) 6. Alignment tool 7. Thread forming
More informationPatent Pending EXTENDED-DUTY PISTON PUMP
TM Patent Pending EXTENDED-DUTY PISTON PUMP O p e r a t i o n & I n s t a l l a t i o n M a n u a l P/N 95222 Rev. 9-29-9 4 2 6 psi 9 1 12 16 14 2 4 6 8 1 INCHES W.C. 4 2 6 N psi IN 1 12 16 14 EXTENDED-DUTY
More informationSRX R. Remediation Pumps. Simply Reliable
SRX R Remediation Pumps Simply Reliable The SRX pump is based on a simple, innovative design and built with fi eld-proven components. The result: a reliable pump to meet the demands of your remediation
More informationSRX. Remediation Pumps. Simply Reliable
SRX Remediation Pumps Simply Reliable The SRX is a based on a simple, innovative design and built with fi eld-proven components. The result: a reliable pump to meet the demands of your remediation site.
More informationPCC O P E R A T I O N S. Pump Cycle Counter M A N U A L. Environmental Systems
O P E R A T I O N S Environmental Systems PCC Pump Cycle Counter M A N U A L PO Box 3726 Ann Arbor, Michigan 48106-3726 (800) 624-2026 North America Only (734) 995-2547 Tele. (734) 995-1170 Fax info@qedenv.com
More informationMaintenance Information
45761848 Edition 3 February 2014 Air Die Grinder AC4A, SC4A and XC4A Series Maintenance Information Save These Instructions Product Safety Information WARNING Failure to observe the following warnings,
More informationSLM - Sealing Liquid Monitor INSTRUCTIONS FOR USE
INSTRUCTIONS FOR USE 1/8 1 INSTALLATION SLM - Sealing Liquid Monitor INSTRUCTIONS FOR USE 1.1 Mounting The SLM has a mounting plate for simple installation. The SML can be mounted using a bolt already
More information2. Disconnect negative battery cable to avoid possible fuel discharge if an accidental attempt is made to start the engines.
PART #25001 LT1 Adjustable Fuel Pressure Regulator, 1994-1997 PACKING LIST Before installation, use this check list to make sure all necessary parts have been included. ITEM QTY CHECK PART NUMBER DESCRIPTION
More informationSection 10 Chapter 17
Section 10 Chapter 17 24 Valve, 8.3 Liter Engine Air Intake System Note: All coding used in the 8.3 Liter and 9 Liter engine manuals are Cummins engine codes. These engine codes have no meaning to New
More informationInstallation Instructions Supertop NX Twill
Installation Instructions Supertop NX Twill Vehicle Application: Jeep Wrangler Unlimited 2007 Current Part Number: 54823 www.bestop.com - We re here to help! Visit our web site and click on Ask a Question.
More informationInstallation Instructions Supertop NX
Installation Instructions Supertop NX Vehicle Application: Jeep Wrangler JK 2 Door 2007 Current Part Number: 54722 www.bestop.com - We re here to help! Visit our web site and click on Ask a Question. Click
More informationWARNING Carefully Read These Instructions Before Use
DO NOT RETURN THIS SPRAYER TO STORE Call: 1-800-950-4458 Backpack Sprayer Use and Care Manual Manufactured for Northern Tool + Equipment Co., Inc. WARNING Carefully Read These Instructions Before Use Model
More informationNILFISK BA 500 Service Manual
NILFISK BA 500 Service Manual Model 66324400 12/94 Form Number 043023 TABLE OF CONTENTS Batteries...21 Brush Drive Belt Adjustment Or Replacement...7 Brush Drive Motor - Carbon brush Inspection... 8 Brush
More informationInstallation Instructions / Warranty
Installation Instructions / Warranty Citterio 39136XX1 39156XX1 Citterio 39236XX1 Axor Citterio Widespread Lav Mixer 39136XX1 Axor Citterio Bidet Mixer 39236XX1 39136XX1 User instructions Turn the right
More informationThe Chameleon Trac II Patent Pending M-Series User s Manual
The Chameleon Trac II Patent Pending M-Series User s Manual YOU MAY ALSO VIEW OUR GENERAL OPERATION VIDEO ONLINE AT: www.marionbrush.com Please read entire manual prior to using this system. Page 1 The
More informationInstallation Instructions Supertop NX
Installation Instructions Supertop NX Vehicle Application: Jeep Wrangler Unlimited 2007 Current Part Number: 54723 www.bestop.com - We re here to help! Visit our web site and click on Ask a Question. Click
More informationM-3025CB-AV Fuel Pump
SAVE THESE INSTRUCTIONS M-3025CB-AV Fuel Pump Owner s Manual TABLE OF CONTENTS General Information... 2 Safety Instructions... 2 Installation... 3 Operation... 4 Maintenance... 4 Repair... 5 Troubleshooting...
More informationAPCO ASR-400/450 SEWAGE AIR RELEASE VALVES
APCO ASR-400/450 SEWAGE AIR RELEASE VALVES Instruction D12005 December 2012 Instructions These instructions provide installation, operation and maintenance information for the APCO ASR- 400/450 Sewage
More informationDual Phase Extraction Inlet. Patent No Installation Manual. P/N Rev
Patent No. 6520259 Installation Manual P/N 95232 Rev 6-16-11 Table of Contents ing Extraction Inlets track changing water levels to maintain optimum performance 1.Component Identification Page 1 2. How
More informationOperating Manual. Hydra S (W)VAC
Operating Manual Pop up Sprinkler Hydra S (W)VAC PERROT TDP053e.doc Rev. 16.06.2015 Page 1 / 21 Contents 1 SAFETY... 3 1.1 HOW INSTRUCTIONS ARE MARKED IN THIS MANUAL... 3 1.2 HAZARDS OF IGNORING SAFETY
More informationINSTALLATION & USER S GUIDE
REKLUSE MOTOR SPORTS The Rekluse Core EXP Kit with Adjustable Slave Cylinder INSTALLATION & USER S GUIDE Doc ID: 191-7704A Doc Rev: 102915 OVERVIEW This kit replaces the OEM core clutch components including
More informationInstruction Manual Part No
U O asics MODEL MP30 Draw Down Meter PATENT PENDING Instruction Manual Part No. 95180 5-31-07 P.O. Box 3726 Ann Arbor, MI 48106-3726 USA 1-800-624-2026 Fax (734) 995-1170 info@qedenv.com www.qedenv.com
More informationCALIFORNIA TRIMMER MOWER MAINTENANCE MANUAL
CALIFORNIA TRIMMER MOWER MAINTENANCE MANUAL 2 Table of Contents Section 1: General Information Page Handle Assembly Instructions 4 Maintenance All Models 6 Oil Change Procedures All Models 9 Height Adjustment
More informationMeeting our clients needs for over 50 years.
P R O D U C T S C A T A L O G Meeting our clients needs for over 50 years. Over half a century ago, a pipe and fitting specialist noticed that too many field workers were sustaining injuries while trying
More informationTroubleshooting Guide for Pumps ATD ATD ATD5289
PROBLEM: Your pump does not work? There are Three Basic Problems! Troubleshooting Guide for Pumps ATD5217 - ATD5219 - ATD5289 Air Motor Operates but nothing comes out. This is the most common problem.
More information1 CONDIMENT DISPENSING SYSTEMS MODELS MCD-1 & MCD-2
1 CONDIMENT DISPENSING SYSTEMS MODELS MCD-1 & MCD-2 THIS EQUIPMENT CHAPTER SHOULD BE INSERTED IN THE EQUIPMENT MANUAL MANUFACTURED FOR McDONALD S BY PERFECTION EQUIPMENT, INC. 4259 LEE AVENUE GURNEE, ILLINOIS
More informationVane Replacement & Complete Rebuild Manual
National Vacuum Equipment Vane Replacement & Complete Rebuild Manual 607 Challenger Series Rotary Vane Vacuum Pumps MADE IN USA 2013 National Vacuum Equipment, Inc. Revision: 5 (Release) March 2013 No
More informationInstallation Guidelines
JUSV4-K (metal lever handle) & GUSVR (rough) JUSV4-K (white porcelain lever handle) & GUSVR (rough) JUSV43-K (black porcelain lever handle-mto) & GUSVR (rough) 5 " Shower Outlet Tub Outlet 3 "± " IMPORTANT
More informationInstallation Instructions / Warranty
Installation Instructions / Warranty Axor Uno 38020XX1 Axor Uno 38025XX1 Axor Uno 38210XX1 Uno Single-control Lavatory Faucet 38020XX1 Uno Single-control Tall Lavatory Faucet 38025XX1 Uno Single-control
More informationInstallation Instructions / Warranty
Installation Instructions / Warranty 13550181 Rough, Two-Hole Thermostatic Roman Tub 13550181 min 4 3/8 max 18 3/4 2 3/16 2 3/16 Technical Specification Operating pressure: max. 145 psi Recommended operating
More informationInstallation Instructions
Installation Instructions SELECTRONIC PROXIMITY DUAL FLUSH TOILET FLUSH VALVE. /. GPF,.8/. GPF Certified to comply with ASME A.9.M 00 AS America, Inc. M90 REV.. Exposed Flushometer for -/" Top Spud Bowls
More informationInstallation Instructions Sunrider for Hardtop
Installation Instructions Sunrider for Hardtop Installation Instructions Sunrider for Hardtop Vehicle Application: Jeep Wrangler / Wrangler Unlimited 2007- current Part Number 52450 Installation Tips Before
More informationAP4/SPG4 Combo Pump. AutoPump/Speci c Gravity Skimmer Controllerless System (for 4-inch wells or larger)
O P E R A T I O N S M A N U A L AutoPump/Speci c Gravity Skimmer Controllerless System (for 4-inch wells or larger) PO Box 3726 6095 Jackson Road Ann Arbor, Michigan 48106-3726 (800) 624-2026 North America
More informationInstallation Instructions
Preparing your vehicle to install your brake system upgrade 1. Rack the vehicle. 2. If you don t have a rack, then you must take extra safety precautions. 3. Choose a firmly packed and level ground to
More informationInsta-Valve 250 Patriot TM
Insta-Valve 250 Patriot TM 4-12 Nominal Size Installation Instructions for use with the Hydra-Core Pipewall Sampling Kit IV250MAN 4-12 IV 250 PWSK v1.93 Revised 07/11/2018 Covered by United States Patent
More informationInstallation Instructions / Warranty. Raindance Allrounder 28110XX1 Wall Outlet Adapter with Hose Connection 28108XX1
Installation Instructions / Warranty Raindance Allrounder 28110XX1 Wall Outlet Adapter with Hose Connection 28108XX1 Raindance Allrounder 28110XX1 Technical Data Max. flow rate of showerhead 2.5 gpm Determining
More informationTechnical Data P3 PISTON POWER PUMP NON-ELECTRIC CONDENSATE PUMP SD 9952B
Technical Data SD 9952B SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NEW YORK, 12586-2035 P3 PISTON POWER PUMP NON-ELECTRIC CONDENSATE PUMP Pressures To 250 PSIG (20.7 barg) Temperatures
More informationFebruary 26, ch.12.notebook. Ch. 12. Preventative Maintenance and Troubleshooting. Feb 23 5:03 PM
Ch. 12 Preventative Maintenance and Troubleshooting Feb 23 5:03 PM 1 Why PM? preventive maintenance certain maintenance tasks must be performed regularly to keep an engine working properly helps premature
More informationSachs 48mm Closed Cartridge fork Service Manual
Sachs 48mm Closed Cartridge fork Service Manual 1 Fork seal driver 2 Special soft jaws 3 Fork cap wrench 4 Rebound rod holding tool 5 Compression assembly holding tool 6 Retaining clip tool Special Tools
More informationInstallation Instructions / Warranty. Starck 10458XX1
Installation Instructions / Warranty Starck 10458XX1 Axor Starck Free-Standing Tub Filler 10458XX1 Technical Specification Maximum water pressure 145 psi Recommended water pressure 14.5-72 psi Maximum
More information36-1 DP PLEASE READ BEFORE USING THIS EQUIPMENT
36-1 DP PLEASE READ BEFORE USING THIS EQUIPMENT DP 36-1 Assembly Instructions PLEASE READ INSTRUCTIONS COMPLETELY BEFORE STARTING We thank you for purchasing the DP-36 pressure system. This system has
More informationINSTALLATION AND MAINTENANCE OF TOP LOADING ARM
INSTALLATION AND MAINTENANCE OF TOP LOADING ARM D TABLE OF CONTENTS 1. INTRODUCTION 04 2. SPECIFICATION OF THE REDLANDS LOADING ARM 04 3. INSTALLING THE LOADING ARM 3.1. Installation Procedures 05 4.
More informationTREASURE VALLEY IRRIGATION CONFERENCE
TREASURE VALLEY IRRIGATION CONFERENCE CORBY GARRETT AQUA IRRIGATION Four Rivers Cultural Center Ontario, Oregon December 14, 2017 DRIP IRRIGATION MAINTENANCE DRIP IRRIGATION MAINTENANCE SYSTEM STARTUP
More informationInstallation Instructions
Installation Instructions SELECTRONIC DC POWERED PROXIMITY EXPOSED URINAL FLUSH VALVE 0., 0., 0. &.0 GPF Certified to comply with ASME A.9. 0 AS America, Inc. Exposed Flushometer for /" Top Spud Urinals
More informationFluid-O-Tech ROTOFLOW ROTARY VANE PUMP REBUILD MANUAL
Fluid-O-Tech PUMP TECHNOLOGY AT ITS BEST WWW.FLUID-O-TECH.COM Office: 161 Atwater St., Plantsville, CT 06479 Phone: (860) 276-9270 Fax: (860) 620-0193 ROTOFLOW ROTARY VANE PUMP REBUILD MANUAL 08/09 Ed.,
More informationTooling Assistance Center
Safeguards are designed into this application equipment to protect operators and maintenance personnel from most hazards during equipment operation. However, certain safety precautions must be taken by
More informationIMPORTANT INFORMATION
IMPORTANT INFORMATION Do Not Proceed Until You Read This! Walker Engineering makes every effort to ensure our orders are packed to withstand the rigors of shipping and arrive at their destination intact
More informationPOR-15 Kits. Super Starter Kits $22.99
POR-15 Kits Super Starter Kits $22.99 We created the SUPER STARTER KIT in response to requests from customers anxious to try out the entire 3-step rust-stopping system, as well as those customers who need
More informationInstallation Instructions / Warranty
Installation Instructions / Warranty Interaktiv Retroaktiv 4-Hole Roman Tub Trim Interaktiv & Retroaktiv 4-Hole Roman Tub Trim These instructions cover the following trim kits: Interaktiv Solaris Stratos
More informationWEBER CARBURETOR TROUBLESHOOTING GUIDE
This guide is to help pinpoint problems by diagnosing engine symptoms associated with specific vehicle operating conditions. The chart will guide you step by step to help correct these problems. For successful
More informationInstallation Instructions / Warranty
Installation Instructions / Warranty Axor Citterio 39133XX1 Axor Citterio 39135XX1 Axor Citterio 39233XX1 Axor Citterio 39235XX1 Axor Citterio Widespread Lavatory Faucet Axor Citterio Widespread Bidet
More informationCrispin Valves Operating Guide. Crispin
Crispin Valves Operating Guide Crispin Since 1905 Crispin Multiplex Manufacturing Co. 600 Fowler Avenue Berwick, PA 18603 1-800-AIR-VALV T: (570) 752-4524 F: (570) 752-4962 www.crispinvalve.com sales@crispinvalve.com
More informationUser Manual. MVP IV Series Groundwater Pumps. Version 2.2. Durham Geo Slope Indicator 2175 West Park Court Stone Mountain, GA USA
MVP IV Series Groundwater Pumps User Manual Version 2.2 Durham Geo Slope Indicator 2175 West Park Court Stone Mountain, GA 30087 USA Phone: 800-837-0864 or +1.770.465.7557 Fax: 770.465.7447 e-mail: solutions@durhamgeo.com
More informationDEFENDER SERIES. 5 Gallon, Double Walled, Field Replaceable Spill Container Model Series INSTALLATION, OPERATION, & MAINTENANCE
DEFENDER SERIES 5 Gallon, Double Walled, Field Replaceable Spill Container Model 705-550 Series INSTALLATION, OPERATION, & MAINTENANCE Franklin Fueling Systems 3760 Marsh Rd. Madison, WI 53718 USA Tel:
More informationPage 1 of 19. Part# /10/2006
Part# 1002733-01 10/10/2006 This manual contains important information concerning the installation and operation of the gun washers listed above. Read manual thoroughly and keep for future reference INSTRUCTIONS
More informationWARM ENGINE STARTING PROCEDURE
saw starting COLD ENGINE STARTING PROCEDURE 1. Pull the choke lever out. 2. Lock the throttle in the start position by depressing and holding the throttle lock button (C) while releasing the trigger (A)
More informationPart# JL AIR IT UP 4 Tire On Board Air Delivery System. (Requires External Air Source)
Part# 18-1819 JL AIR IT UP 4 Tire On Board Air Delivery System (Requires External Air Source) The most up-to-date instructions always visit www.updownair.com www.updownair.com 833-226-4863 I M P O R T
More informationArmstrong Double Duty 6 Steam Trap/Pump Combination Installation and Maintenance
Armstrong Double Duty 6 Steam Trap/Pump Combination Installation and Maintenance 119 Overview Warning: This bulletin should be used by experienced personnel as a guide to the installation and maintenance
More informationPypes Polished Shorty Headers (05-10 V6):
Pypes Polished Shorty Headers (05-10 V6): Introduction: The kit comes complete with replacement hardware and gaskets and can be easily done in your driveway. The hardware supplied for install includes
More informationOWNERS SERVICE MANUAL INSTALLATION, OPERATING AND SERVICING. Model SGMH 781K. Model SGMH 783K
OWNERS SERVICE MANUAL INSTALLATION, OPERATING AND SERVICING Model SGMH 781K ABC (AMMONIUM PHOSPHATE BASE) Model SGMH 783K PK (Potassium Bicarbonate) RECHARGE FIRE EXTINGUISHERS IMMEDIATELY AFTER ANY USE
More informationInstallation Instructions Supertop for Truck
Installation Instructions Supertop for Truck Vehicle Application: Toyota Tacoma Double Cab 2005 - Current (5 ft.) Part Number: 76308 US Patent 6827391 www.bestop.com - We re here to help! Visit our web
More informationInstallation Instructions / Warranty
Installation Instructions / Warranty Metris 31436XX1 Talis 32313XX1 Focus 31732XX1 Metris 31446XX1 Talis 32314XX1 Focus 31733XX1 Trim, 3- and 4-Hole Roman Tub Sets 3-Hole 4-Hole Metris 31436001 31446001
More informationRAMPAGE POWER LIFT RAMP
RAMPAGE POWER LIFT RAMP INSTALLATION AND OPERATING INSTRUCTIONS (3/10/07) The Rampage Power Lift Ramp is the fast, easy, and safe way to load a motorcycle into a truck. One person can load or unload a
More informationService Bulletin Published by Sudden Service, Inc.
Service Bulletin Published by Sudden Service, Inc. Volume 18 / Number 2 / February 1, 2018 Louisville, Mississippi Preventative Maintenance (PM) Requirements for Diesel Engines Equipped With EPA Tier 4
More informationInstallation Instructions / Warranty
Installation Instructions / Warranty Hansgrohe HighArc Bar Faucets HighArc Bar Faucets These instructions cover the following models: 06688XX0 06696XX0 06699XX0 06857XX0 06980XX0 Solaris Stratos Metro
More informationMASTER COALESCER JR & PORTABLE MASTER COALESCER JR AIR PUMP MODEL INSTALLATION MANUAL
MASTER COALESCER JR & PORTABLE MASTER COALESCER JR AIR PUMP MODEL INSTALLATION MANUAL INSTALLATION: CHOOSING THE LOCATION: Locate the coalescer as near to the intended point of use as possible. Avoid high
More informationInstruction Manual. Part No Rev 2. A Graco Company
Instruction Manual Part No. 95312 8-14-2017 Rev 2 A Graco Company QED Environmental Systems 2355 Bishop Circle West Dexter, MI 48130 US Toll Free: 800-624-2026 Tel: +1 (734) 995-2547 Fax: +1 (734) 995-1170
More informationInstallation Instructions Supertop for Truck
Installation Instructions Supertop for Truck Vehicle Application: Ford F-150 Regular / Super Cab 2004 2011 (6.5 ft.) Part Number: 76305 US Patent 6827391 www.bestop.com - We re here to help! Visit our
More informationWhat s Eating Your Pump?
What s Eating Your Pump? Selecting Submersible Pumps for Landfill Leachate/Condensate Removal David Kaminski QED Environmental Systems Inc. Copyright QED Environmental Systems, Inc. 2007, 2008, 2009; all
More informationINSTALLATION GUIDE. Clutch Cable Actuated Models Manual Revision:
REKLUSE MOTOR SPORTS The z-start Pro Clutch INSTALLATION GUIDE Clutch Cable Actuated Models 191-800 Manual Revision: 061810 2002 Rekluse Motor Sports Rekluse Motor Sports, Inc. 110 E. 43rd Street Boise,
More informationOperator s Manual Version 1.21 TR-200. Peristaltic Pump. Durham Geo Slope Indicator 2175 West Park Court Stone Mountain, GA USA
Peristaltic Pump TR-200 Operator s Manual Version 1.21 Durham Geo Slope Indicator 2175 West Park Court Stone Mountain, GA 30087 USA Phone: 800-837-0864 or +1.770.465.7557 Fax: 770.465.7447 e-mail: solutions@durhamgeo.com
More informationTray Lift Assist Device. User Manual and Operating Instructions
Tray Lift Assist Device User Manual and Operating Instructions Table of Contents Section 1: Device Overview 1.1: Overview 1.2: Subassemblies 1.3: Main Features 1.4: Safety Devices Section 2: User Instructions
More informationINSTALLATION GUIDE. Doc ID Revision
REKLUSE MOTOR SPORTS INSTALLATION GUIDE OVERVIEW Doc ID 191-6300 Revision 013017 Read the separate included Safety Information document before operating the vehicle with the product installed. If you are
More informationInstallation Operation Parts
OWNER S MANUAL BATTERY BACKUP SUMP Installation Operation Parts For further operating, installation or maintenance assistance, Call 98-8-05 PRINTED IN U.S.A. M-8 (/9) RULES FOR SAFE INSTALLATION AND OPERATION
More informationRocker Lever Assembly
003-009 Rocker Lever Assembly Preparatory Steps Remove the air piping from the intake manifold. Remove the rocker lever cover. Refer to Procedure 003-011 in Section 3. Remove the engine brakes, if equipped.
More informationOperation and Maintenance Manual Model.75,, 3, 5, 8, 0, 0, 5, 35, 50 http://www.torsionx.com Use the MaxDrv Series Square Drive Torque Wrench Model.75,, 3, 5, 8, 0, 0, 5, 35, 50 to install and remove threaded
More informationCSO / CP PUMPS Vertical Spindle Type Installation, Operation and Maintenance Manual
CSO / CP PUMPS Vertical Spindle Type Installation, Operation and Maintenance Manual www.sameng.co.za (011) 823 4250 Proud Manufacturers of SAMCO Pumps Contents INTRODUCTION 3 LOCATION OF UNIT 3 INSTALLATION
More informationHIGH PRESSURE CONTROL VALVE PISTON BALANCED
PISTON BALANCED All Rights Reserved. All contents of this publication including illustrations are believed to be reliable. And while efforts have been made to ensure their accuracy, they are not to be
More informationTABLE 1-1 GPM FLOW RATE PROPORTIONER, 1/4 I.D. TUBING Injection Rates For Viscosities Shown Metering Tip Color
Blend Safe II Dispensing System is a modular, locking dispensing system that allows user to dispense chemicals safely, control dispenser inventory and has the flexibility in the field to meet changing
More informationPRO RATCHET UNIVERSAL SHIFTER
Installation Instructions PRO RATCHET UNIVERSAL SHIFTER Fits: GM, Ford and Chryslers w/automatic Transmission See Application Guide for Specific Vehicles Catalog # 80842 WORK SAFELY! For maximum safety,
More informationJOULE RETRACTABLE RETARDER INSTALLATION & MAINTENANCE
New Joules Engineering North America Inc. An Argent Industrial Ltd. Company JOULE RETRACTABLE RETARDER INSTALLATION & MAINTENANCE Tech.-Lit. 4, Date 03/2007 4401 Clary Blvd., Kansas City, MO 64130 (816)
More informationNOTE: Visit our website at for video repair procedures, under the Tools section.
Repair Instructions Hypro Repair Tools: Tool Box No. 3010-0168 1/4" Allen Wrench No. 3020-0008 Support Bars (2) No. 3010-0064 Port Brush No. 3010-0066 1/16" Allen Wrench No. 3020-0009 Brush Holder No.
More informationM-8100EP. Installation Guide ENGINEERED PLASTIC MANIFOLD SERIES. Introduction. A. Assemble Manifold Components
Introduction The Pro Manifolds with Integrated adaptor are designed for use in Hydronic radiant panel heating and cooling applications. They are available in various sizes, configurations, and options
More informationPressurized Bead Filters
Pressurized Bead Filters Installation Instructions Table of Contents Safety Information Installation Assembly Start Up Maintenance Troubleshooting Warranty Safety Information: 1. Installation should be
More informationATD-6810 SPRAY GUN W/CUP INSTRUCTION MANUAL
ATD-6810 SPRAY GUN W/CUP INSTRUCTION MANUAL Read this Instruction Manual carefully and understand it completely, basic precaution should be strictly followed to prevent the damage to the tool and injury
More informationHYDRAULICS. TX420 & & lower. Hydraulic Tandem Pump Removal. 4. Remove the LH side panel (Fig. 0388).
TX420 & 425 240000299 & lower 4. Remove the LH side panel (Fig. 0388). Hydraulic Tandem Pump Removal Note: Cleanliness is a key factor in a successful repair of any hydraulic system. Thoroughly clean all
More informationLEAK TEST PROCEDURE MRTALPCH611LDC REMOTE READY LIFTERS W/ 3 BUTTON CONTROL APPLICABLE TO LIFTERS WITH SERIAL NUMBERS GREATER THAN #
LEAK TEST PROCEDURE MRTALPCH611LDC REMOTE READY LIFTERS W/ 3 BUTTON CONTROL APPLICABLE TO LIFTERS WITH SERIAL NUMBERS GREATER THAN # 20100742 TESTING AND MAINTENANCE MUST BE DONE BY A QUALIFIED PERSON
More information#9040 FUEL TANK SWEEPER
#9040 FUEL TANK SWEEPER INSTRUCTION MANUAL FILTERS AND REMOVES FINE BIO-CONTAMINANTS, ALGAE, ETC. SWEEPING PROCESS REMOVES LARGE CONTAMINANTS FROM OIL TANKS SUCH AS RUST, WATER, CRUDE AND DIRT CIRCULATES
More informationSentinel 250 Fire Hydrant
Maintenance Instructions manual table of contents PAGE Sentinel 250 Fire Hydrant Inspection and Lubrication 2 Rotating Hydrant to Face Desired Direction 3 Installing Extension Section 3-6 Restoring Service
More informationSUPERHONE Installation * Operation * Maintenance * Replacement Parts
SUPERHONE Installation * Operation * Maintenance * Replacement Parts I.C.M., Inc. 10630 South Garfield Avenue South Gate, CA 90280-7395 Telephone: 562/869-3004 888/351-2570 Fax: 562/869-3005 Website: www.icm2000.com
More information150 Series Brass Horizontal Float Valve. Technical Information
150 Series Brass Horizontal Float Valve Technical Information HORIZONTAL FLOAT VALVES Based on a simple yet effective operating principle, Philmac horizontal float valves are quick and easy to install
More information