XV80 UPFLOW/HORIZONTAL 2-STAGE, VARIABLE SPEED GAS-FIRED FURNACE

Size: px
Start display at page:

Download "XV80 UPFLOW/HORIZONTAL 2-STAGE, VARIABLE SPEED GAS-FIRED FURNACE"

Transcription

1 UPF/HORIZONTAL 2-, VARIABLE SPEED GAS-FIRED FURNACE XV80 MODELS TUD2B060A9V3VB TUD2B080A9V3VB TUD2C080A9V4VB TUD2C080B9V4VB TUD2B00A9V3VB TUD2C00A9V5VB TUD2C00B9V5VB TUD2DA9V5VB TUD2DB9V5VB TUD2DA9V5VB Two-Stage Fan Assisted Combustion System PUB. NO Trane

2 General Features NATURAL GAS MODELS Central Heating furnace designs are certified by the American Gas Association for both natural and L.P. gas. Limit setting and rating data were established and approved under standard rating conditions using American National Standards Institute standards. SAFE OPERATION The Integrated System Control has solid state devices, which continuously monitor for presence of flame, when the system is in the heating mode of operation. Dual solenoid combination gas valve and regulator provide extra safety. QUICK Durable, cycle tested, heavy gauge aluminized steel heat exchanger quickly transfers heat to provide warm conditioned air to the structure. Low energy power vent blower, to increase efficiency and provide a positive discharge of gas fumes to the outside. BURNERS Multiport In-shot burners will give years of quiet and efficient service. All models can be converted to L.P. gas. INTEGRATED SYSTEM CONTROL Exclusively designed operational program provides total control of furnace limit sensors, blowers, gas valve, flame control and includes self diagnostics for ease of service. Also contains connection points for E.A.C./ humidifier. AIR DELIVERY The variable speed, direct drive blower motor, has sufficient airflow for most heating and cooling requirements, will switch from heating to cooling speeds on demand from room thermostat. The blower door safety switch will prevent or terminate furnace operation when the blower door is removed. Some models are available with high efficiency blowers. STYLING Heavy gauge steel and wrap-around cabinet construction is used in the cabinet with baked-on enamel finish for strength and beauty. The heat exchanger section of the cabinet is completely lined with foil faced fiberglass insulation. This results in quiet and efficient operation due to the excellent acoustical and insulating qualities of fiberglass. Built-in bottom pan and alternate bottom, left or right side return air connection provision. FEATURES AND GENERAL OPERATION The XV80 High Efficiency Gas Furnaces employ a Hot Surface Ignition system, which eliminates the waste of a constant burning pilot. The integrated system control lights the main burners upon a demand for heat from the room thermostat. Complete front service access. a. Low energy power venter b. Vent proving pressure switch. 6 Trane

3 Contents Feature Summary 2 Features and Benefits 4 Standard Equipment 4 Optional Equipment 4 General Data 5 TUD2B060A9V3VB 5 TUD2B080A9V3VB 5 TUD2C080A9V4VB 5 TUD2C080B9V4VB 6 TUD2B00A9V3VB 6 TUD2C00A9V5VB 6 TUD2C00B9V5VB 7 TUD2DA9V5VB 7 TUD2DB9V5VB 7 TUD2DA9V5VB 7 Performance Data 8 Electric Data 8 Field Wiring Diagrams Dimensions

4 Features and Benefits XV80 STANDARD EQUIPMENT Upflow/Horizontal and Power supply 5//60 2-stage gas valve 2-speed venter speed blower motor Silicon Nitride hot surface igniter with adaptive heat up Integrated solid state control Attractive color accents Heavy gauge aluminized steel heat exchanger Multi-port In-shot burners Complete front service access Alternate bottom/left/right return air Slide out blower assembly Hinged blower door Perfect fit door catches Insulated blower door Gasketed blower door Internal filter rack Standard filter sizes Two-tone color Direct drive, variable speed motor Integrated solid state control with self-diagnostics Common vent capability Cleanable framed filters Optional L.P. conversion kit Left/right gas connection Accessory hook-up capability Selectable cooling fan off delay eliminates need for BAY24X0 time delay kit Enhanced cooling control XV80 OPTIONAL EQUIPMENT Thermostat, Mechanical 2-Stage Heating/-Stage Cooling... TAYSTAT24 [ ] Thermostat, Mechanical Heating Only With Fan Switch... BAYSTAT303 [ ] Thermostat, Mechanical Heating Only... BAYSTAT388 [ ] Thermostat, Heating/Cooling Single Stage (Mounts Horizontally)...AY28X092 [ ] Thermostat, Electronic Non-programmable -Stage Heating/-Stage Cooling... BAYSTAT370 [ ] Thermostat, Electronic Programmable (5-2) -Stage Heating/-Stage Cooling... BAYSTAT3 [ ] Thermostat, Heating/Cooling Single Stage (Mounts Vertically)... BAYSTAT305 [ ] Thermostat, Electronic Programmable 2-Stage Heating/2-Stage Cooling... TAYSTAT302C [ ] Thermostat, Electronic Programmable -Stage Heating/-Stage Cooling... TAYSTAT300C [ ] Propane Conversion Kit... BAYLPKTA [ ] Electronic Air Filter, Perfect Fit High Efficiency (7-/2" Wide Gas Furnace)... TFM75A9FR0 [ ] Electronic Air Filter, Perfect Fit High Efficiency (2" Wide Gas Furnace)... TFMA9FR0 [ ] Electronic Air Filter, Perfect Fit High Efficiency (24-/2" Wide Gas Furnace)... TFM2A9FR0 [ ] Electronic Air Filter, Perfect Fit Standard Efficiency (7-/2" Wide Gas Furnace)...TFP75A9FR0 [ ] Electronic Air Filter, Perfect Fit Standard Efficiency (2" Wide Gas Furnace)...TFPA9FR0 [ ] Electronic Air Filter, Perfect Fit Standard Efficiency (24-/2" Wide Gas Furnace)...TFP2A9FR0 [ ] Coil Enclosure (7-/2" Wide Cabinets)...BAYCLE7A722A [ ] Coil Enclosure (2" Wide Cabinets)...BAYCLE2A230A [ ] Coil Enclosure (24-/2" Wide Cabinets)...BAYCLE24A20A [ ] Side Filter Rack... BAYFLTR0 [ ] High Altitude Switch...BAYHALT2 [ ] Masonry Chimney Vent Kit (Upflow models only)...bayvent800b [ ] Filter Rack Kit... BAYRACK960A [ ] Available for models with 800 or greater which require an additional side return

5 TUD-R9V PRODUCT SPECIFICATIONS MODEL TYPE RATINGS 2 st Stage Input BTUH st Stage Capacity BTUH (ICS) 3 2nd Stage Input BTUH 2nd Stage Capacity BTUH (ICS) 3 Temp. rise (Min.-Max.) F. BER DRIVE Diameter - Width (In.) No. Used Speeds (No.) vs. in. w.g. Motor HP R.P.M. Volts / Ph / Hz FLA COMBUSTION FAN - Type Drive - No. Speeds Motor HP PSC [Shaded Pole] - RPM Volts / Ph / Hz FLA PSC [Shaded pole] FILTER Furnished? Type Recommended Hi Vel. (No.-Size-Thk.) VENT Size (In.) HEAT EXCHANGER Type -Fired -Unfired Gauge (Fired) ORIFICES Main Nat. Gas. Qty. Drill Size L.P. Gas Qty. Drill Size GAS VALVE PILOT SAFETY DEVICE Type BURNERS Type Number POWER CONN. V / Ph / Hz 4 Ampacity (In Amps) Max. Overcurrent Protection (Amps) PIPE CONN. SIZE (In.) DIMENSIONS Crated (In.) WEIGHT Shipping (Lbs.) / Net (Lbs.) TUD2B060A9V3VB Upflow / Horizontal,000 3,0 60,000, Direct 0 x 7 See Airflow Table /2 5// Centrifugal Direct - 2 /00 / [/] - 25/727 5// /0. / [0.23/0.] Yes High Velocity - 7x25 - in. 4 Round Alum. Steel - Type Redundant - Two Stage Hot Surface Ignition Multi-port In-shot 3 5// /2 H x W x D 4-3/4 x 9-/2 x 30-/2 36 / 26 TUD2B080A9V3VB Upflow / Horizontal,000 4,600 80,000 64, Direct 0 x 7 See Airflow Table /2 5// Centrifugal Direct - 2 /00 / [/] - 25/727 5// /0. / [0.23/0.] Yes High Velocity - 7x25 - in. 4 Round Alum. Steel - Type Redundant - Two Stage Hot Surface Ignition Multi-port In-shot 4 5// /2 H x W x D 4-3/4 x 9-/2 x 30-/2 42 / 32 TUD2C080A9V4VB Upflow / Horizontal,000 4,600 80,000 64, Direct 0 x 0 See Airflow Table 3/4 5// Centrifugal Direct - 2 /00 / [/] - 25/727 5// /0. / [0.23/0.] Yes High Velocity - x25 - in. 4 Round Alum. Steel - Type Redundant - Two Stage Hot Surface Ignition Multi-port In-shot 4 5// /2 H x W x D 4-3/4 x 23 x 30-/2 66 / 55 Central Furnace heating designs are certified to ANSI Z2.47 / CSA For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per,000 feet for elevations above 2,000 feet above sea level. For Canadian applications, above input ratings (BTUH) are up to 4,0 feet, derate 4% per,000 feet for elevations above 4,0 feet above sea level. 3 Based on U.S. government standard tests. 4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes DATA SUBJECT TO CHANGE WITHOUT NOTICE 5

6 TUD-R9V PRODUCT SPECIFICATIONS MODEL TYPE RATINGS 2 st Stage Input BTUH st Stage Capacity BTUH (ICS) 3 2nd Stage Input BTUH 2nd Stage Capacity BTUH (ICS) 3 Temp. rise (Min.-Max.) F. BER DRIVE Diameter - Width (In.) No. Used Speeds (No.) vs. in. w.g. Motor HP R.P.M. Volts / Ph / Hz FLA COMBUSTION FAN - Type Drive - No. Speeds Motor HP PSC [Shaded Pole] - RPM Volts / Ph / Hz FLA PSC [Shaded pole] FILTER Furnished? Type Recommended Hi Vel. (No.-Size-Thk.) VENT Size (In.) HEAT EXCHANGER Type -Fired -Unfired Gauge (Fired) ORIFICES Main Nat. Gas. Qty. Drill Size L.P. Gas Qty. Drill Size GAS VALVE PILOT SAFETY DEVICE Type BURNERS Type Number POWER CONN. V / Ph / Hz 4 Ampacity (In Amps) Max. Overcurrent Protection (Amps) PIPE CONN. SIZE (In.) DIMENSIONS Crated (In.) WEIGHT Shipping (Lbs.) / Net (Lbs.) TUD2C080B9V4VB 5 Upflow / Horizontal,000 4,600 80,000 64, Direct 0 x 0 See Airflow Table 3/4 5// Centrifugal Direct - 2 /00 / [/] - 25/727 5// /0. / [0.23/0.] Yes High Velocity - x25 - in. 4 Round Alum. Steel - Type Redundant - Two Stage Hot Surface Ignition Multi-port In-shot 4 5// /2 H x W x D 4-3/4 x 23 x 30-/2 66 / 55 TUD2B00A9V3VB Upflow / Horizontal 65,000,000 00,000 80, Direct 0 x 7 See Airflow Table /2 5// Centrifugal Direct - 2 /75 / [/] /868 5// /0. / [0.22/0.] Yes High Velocity - 7x25 - in. 4 Round Alum. Steel - Type Redundant - Two Stage Hot Surface Ignition Multi-port In-shot 5 5// /2 H x W x D 4-3/4 x 9-/2 x 30-/2 42 / 32 TUD2C00A9V5VB Upflow / Horizontal 65,000,000 00,000 79, Direct 0 x 0 See Airflow Table 5// Centrifugal Direct - 2 /75 / [/] /868 5// /0. / [0.22/0.] Yes High Velocity - x25 - in. 4 Round Alum. Steel - Type Redundant - Two Stage Hot Surface Ignition Multi-port In-shot 5 5// /2 H x W x D 4-3/4 x 23 x 30-/2 66 / 55 Central Furnace heating designs are certified to ANSI Z2.47 / CSA For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per,000 feet for elevations above 2,000 feet above sea level. For Canadian applications, above input ratings (BTUH) are up to 4,0 feet, derate 4% per,000 feet for elevations above 4,0 feet above sea level. 3 Based on U.S. government standard tests. 4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes. 5 Model uses high efficiency blower. 6 DATA SUBJECT TO CHANGE WITHOUT NOTICE

7 TUD-R9V PRODUCT SPECIFICATIONS MODEL TYPE RATINGS 2 st Stage Input BTUH st Stage Capacity BTUH (ICS) 3 2nd Stage Input BTUH 2nd Stage Capacity BTUH (ICS) 3 Temp. rise (Min.-Max.) F. BER DRIVE Diameter - Width (In.) No. Used Speeds (No.) vs. in. w.g. Motor HP R.P.M. Volts / Ph / Hz FLA COMBUSTION FAN - Type Drive - No. Speeds Motor HP PSC [Shaded Pole] - RPM Volts / Ph / Hz FLA PSC [Shaded pole] FILTER Furnished? Type Recommended Hi Vel. (No.-Size-Thk.) VENT Size (In.) HEAT EXCHANGER Type -Fired -Unfired Gauge (Fired) ORIFICES Main Nat. Gas. Qty. Drill Size L.P. Gas Qty. Drill Size GAS VALVE PILOT SAFETY DEVICE Type BURNERS Type Number POWER CONN. V / Ph / Hz 4 Ampacity (In Amps) Max. Overcurrent Protection (Amps) PIPE CONN. SIZE (In.) DIMENSIONS Crated (In.) WEIGHT Shipping (Lbs.) / Net (Lbs.) TUD2C00B9V5VB 5 Upflow / Horizontal 65,000,000 00,000 79, Direct 0 x 0 See Airflow Table 5// Centrifugal Direct - 2 /75 / [/] /868 5// /0. / [0.22/0.] Yes High Velocity - x25 - in. 4 Round Alum. Steel - Type Redundant - Two Stage Hot Surface Ignition Multi-port In-shot 5 5// /2 H x W x D 4-3/4 x 23 x 30-/2 66 / 55 TUD2DA9V5VB Upflow / Horizontal 78,000 62,0,000 97, Direct 0 x 0 See Airflow Table 5// Centrifugal Direct - 2 /60 / [/85] /2225 5//60.4/0.5 / [0.25/0.2] Yes High Velocity - 24x25 - in. 4 Round Alum. Steel - Type Redundant - Two Stage Hot Surface Ignition Multi-port In-shot 6 5// /2 H x W x D 4-3/4 x 26-/2 x 30-/2 93 / 8 TUD2DB9V5VB 5 Upflow / Horizontal 78,000 62,0,000 97, Direct 0 x 0 See Airflow Table 5// Centrifugal Direct - 2 /60 / [/85] /2225 5//60.4/0.5 / [0.25/0.2] Yes High Velocity - 24x25 - in. 4 Round Alum. Steel - Type Redundant - Two Stage Hot Surface Ignition Multi-port In-shot 6 5// /2 H x W x D 4-3/4 x 26-/2 x 30-/2 93 / 8 TUD2DA9V5VB Upflow / Horizontal 9,000 72,800,000, Direct 0 x 0 See Airflow Table 5// Centrifugal Direct - 2 /60-300/23 5//60.6/0. Yes High Velocity - 24x25 - in. 4 Round Alum. Steel - Type Redundant - Two Stage Hot Surface Ignition Multi-port In-shot 7 5// /2 H x W x D 4-3/4 x 26-/2 x 30-/2 97 / 85 Central Furnace heating designs are certified to ANSI Z2.47 / CSA For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per,000 feet for elevations above 2,000 feet above sea level. For Canadian applications, above input ratings (BTUH) are up to 4,0 feet, derate 4% per,000 feet for elevations above 4,0 feet above sea level. 3 Based on U.S. government standard tests. 4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes. 5 Model uses high efficiency blower DATA SUBJECT TO CHANGE WITHOUT NOTICE 7

8 ST 2ND *UD2B060A9V3VB FURNACE () AND POWER () VS. EXTERNAL STATIC DIP SWITCH SW7 SW OUTDOOR UNIT SIZE (TONS) *UD2B060A9V3VB FURNACE COOLING () AND POWER () VS. EXTERNAL STATIC (3 / TON) DIP SWITCH SW SW2 SW3 SW ON ON OFF ON (0 / TON) ON ON OFF OFF (4 / TON) ON ON ON OFF (3 / TON) OFF ON OFF ON (0 / TON) OFF ON OFF OFF (4 / TON) OFF ON ON OFF (3 / TON) ON OFF OFF ON (0 / TON) ON OFF OFF OFF (4 / TON) ON OFF ON OFF (3 / TON) OFF OFF OFF ON ** ** (0 / TON) OFF OFF OFF OFF (4 / TON) OFF OFF ON OFF NOTES:. *FIRST LETTER MAY BE "A" OR "T" 2. **FACTORY. 3. CONTINUOUS FAN : OR COOLING IS APPROXIMATELY % OF SELECTED COOLING VALUE /TON IS RECOMMENDED FOR VARIABLE SPEED APPLICATION FOR COMFORT & HUMID CLIMATE : IS 0 /TON: 4 /TON IS FOR DRY CLIMATE DATA SUBJECT TO CHANGE WITHOUT NOTICE

9 *UD2B080A9V3VB FURNACE () AND POWER () VS. EXTERNAL STATIC DIP SWITCH SW 7 SW ST ND MEDIUM ** ON OFF OUTDOOR UNIT SIZE (TONS) *UD2B080A9V3VB FURNACE COOLING () AND POWER () VS. EXTERNAL STATIC (3 /TON) DIP SWITCH SW SW 2 SW 3 SW OFF ON OFF ON (0 /TON) OFF ON OFF OFF (4 /TON) OFF ON ON OFF (3 /TON) ON OFF OFF ON (0 /TON) ON OFF OFF OFF (4 /TON) ON OFF ON OFF (3 /TON) OFF OFF OFF ON ** ** (0 /TON) OFF OFF OFF OFF (4 /TON) OFF OFF ON OFF NOTES:. * First Letter may be "A" or "T" 2. ** Factory setting 3. Continuous Fan Setting: Heating or Cooling airflow is approximately % of selected Cooling value cfm/ton is recommended for Speed application for COMFORT & HUMID CLIMATE setting; is 0 cfm/ton; 4 cfm/ton is for DRY CLIMATE setting DATA SUBJECT TO CHANGE WITHOUT NOTICE 9

10 *UD2C080A9V4VB FURNACE () AND POWER () VS. EXTERNAL STATIC ST 2ND DIP SWITCH SW 7 SW OUTDOOR UNIT SIZE (TONS) *UD2C080A9V4VB FURNACE COOLING () AND POWER () VS. EXTERNAL STATIC (3 /TON) DIP SWITCH SW SW 2 SW 3 SW ON ON OFF ON (0 /TON) ON ON OFF OFF (4 /TON) ON ON ON OFF (3 /TON) OFF ON OFF ON (0 /TON) OFF ON OFF OFF (4 /TON) OFF ON ON OFF (3 /TON) ON OFF OFF ON (0 /TON) ON OFF OFF OFF (4 /TON) ON OFF ON OFF (3 /TON) OFF OFF OFF ON ** ** (0 /TON) OFF OFF OFF OFF (4 /TON) OFF OFF ON OFF NOTES:. * First Letter may be "A" or "T" 2. ** Factory setting 3. Continuous Fan Setting: Heating or Cooling airflow is approximately % of selected Cooling value cfm/ton is recommended for Speed application for COMFORT & HUMID CLIMATE setting; is 0 cfm/ton; 4 cfm/ton is for DRY CLIMATE setting 0 DATA SUBJECT TO CHANGE WITHOUT NOTICE

11 *UD2C080B9V4VB FURNACE () AND POWER () VS. EXTERNAL STATIC ST 2ND DIP SWITCH SW 7 SW OUTDOOR UNIT SIZE (TONS) *UD2C080B9V4VB FURNACE COOLING () AND POWER () VS. EXTERNAL STATIC (3 /TON) DIP SWITCH SW SW 2 SW 3 SW ON ON OFF ON (0 /TON) ON ON OFF OFF (4 /TON) ON ON ON OFF (3 /TON) OFF ON OFF ON (0 /TON) OFF ON OFF OFF (4 /TON) OFF ON ON OFF (3 /TON) ON OFF OFF ON (0 /TON) ON OFF OFF OFF (4 /TON) ON OFF ON OFF (3 /TON) OFF OFF OFF ON ** ** (0 /TON) OFF OFF OFF OFF (4 /TON) OFF OFF ON OFF NOTES:. * First Letter may be "A" or "T" 2. ** Factory setting 3. Continuous Fan Setting: Heating or Cooling airflow is approximately % of selected Cooling value cfm/ton is recommended for Speed application for COMFORT & HUMID CLIMATE setting; is 0 cfm/ton; 4 cfm/ton is for DRY CLIMATE setting DATA SUBJECT TO CHANGE WITHOUT NOTICE

12 *UD2B00A9V3VB FURNACE () AND POWER () VS. EXTERNAL STATIC DIP SWITCH SW 7 SW ST ND OUTDOOR UNIT SIZE (TONS) *UD2B00A9V3VB FURNACE COOLING () AND POWER () VS. EXTERNAL STATIC (3 /TON) DIP SWITCH SW SW 2 SW 3 SW ON ON OFF ON (0 /TON) ON ON OFF OFF (4 /TON) ON ON ON OFF (3 /TON) OFF ON OFF ON (0 /TON) OFF ON OFF OFF (4 /TON) OFF ON ON OFF (3 /TON) ON OFF OFF ON (0 /TON) ON OFF OFF OFF (4 /TON) ON OFF ON OFF (3 /TON) OFF OFF OFF ON ** ** (0 /TON) OFF OFF OFF OFF (4 /TON) OFF OFF ON OFF NOTES:. * First Letter may be "A" or "T" 2. ** Factory setting 3. Continuous Fan Setting: Heating or Cooling airflow is approximately % of selected Cooling value cfm/ton is recommended for Speed application for COMFORT & HUMID CLIMATE setting; is 0 cfm/ton; 4 cfm/ton is for DRY CLIMATE setting 2 DATA SUBJECT TO CHANGE WITHOUT NOTICE

13 *UD2C00A9V5VB FURNACE () AND POWER () VS. EXTERNAL STATIC DIP SWITCH SW 7 SW ST ND OUTDOOR UNIT SIZE (TONS) *UD2C00A9V5VB FURNACE COOLING () AND POWER () VS. EXTERNAL STATIC (3 /TON) DIP SWITCH SW SW 2 SW 3 SW ON ON OFF ON (0 /TON) ON ON OFF OFF (4 /TON) ON ON ON OFF (3 /TON) OFF ON OFF ON (0 /TON) OFF ON OFF OFF (4 /TON) OFF ON ON OFF (3 /TON) ON OFF OFF ON (0 /TON) ON OFF OFF OFF (4 /TON) ON OFF ON OFF (3 /TON) OFF OFF OFF ON ** ** (0 /TON) OFF OFF OFF OFF (4 /TON) OFF OFF ON OFF NOTES:. * First letter may be "A" or "T" 2. ** Factory setting 3. Continuous Fan Setting: Heating or Cooling airflow is approximately % of selected Cooling value cfm/ton is recommended for Speed application for COMFORT & HUMID CLIMATE setting; is 0 cfm/ton; 4 cfm/ton is for DRY CLIMATE setting DATA SUBJECT TO CHANGE WITHOUT NOTICE

14 *UD2C00B9V5VB FURNACE () AND POWER () VS. EXTERNAL STATIC DIP SWITCH SW 7 SW ST ND OUTDOOR UNIT SIZE (TONS) *UD2C00B9V5VB FURNACE COOLING () AND POWER () VS. EXTERNAL STATIC (3 /TON) DIP SWITCH SW SW 2 SW 3 SW ON ON OFF ON (0 /TON) ON ON OFF OFF (4 /TON) ON ON ON OFF (3 /TON) OFF ON OFF ON (0 /TON) OFF ON OFF OFF (4 /TON) OFF ON ON OFF (3 /TON) ON OFF OFF ON (0 /TON) ON OFF OFF OFF (4 /TON) ON OFF ON OFF (3 /TON) OFF OFF OFF ON ** ** (0 /TON) OFF OFF OFF OFF (4 /TON) OFF OFF ON OFF NOTES:. * First letter may be "A" or "T" 2. ** Factory setting 3. Continuous Fan Setting: Heating or Cooling airflow is approximately % of selected Cooling value cfm/ton is recommended for Speed application for COMFORT & HUMID CLIMATE setting; is 0 cfm/ton; 4 cfm/ton is for DRY CLIMATE setting DATA SUBJECT TO CHANGE WITHOUT NOTICE

15 *UD2DA9V5VB FURNACE () AND POWER () VS. EXTERNAL STATIC DIP SWITCH SW7 SW ST ND OUTDOOR UNIT SIZE (TONS) *UD2DA9V5VB FURNACE COOLING () AND POWER () VS. EXTERNAL STATIC (See Notes) (3 / TON) DIP SWITCH SW SW2 SW3 SW OFF ON OFF ON (0 / TON) OFF ON OFF OFF (4 / TON) OFF ON ON OFF (3 / TON) ON OFF OFF ON (0 / TON) ON OFF OFF OFF (4 / TON) ON OFF ON OFF (3 / TON) OFF OFF OFF ON ** ** (0 / TON) OFF OFF OFF OFF (4 / TON) OFF OFF ON OFF NOTES: "CONTINUOUS FAN " IS THERMOSTAT FAN SWITCH "ON" AND DIP SWITCHS 5 AND 6 "ON".. *FIRST LETTER MAY BE "A" OR "T" 2. **FACTORY. 3. CONTINUOUS FAN : OR COOLING IS APPROXIMATELY % OF SELECTED COOLING VALUE /TON IS RECOMMENDED FOR VARIABLE SPEED APPLICATION FOR COMFORT & HUMID CLIMATE : IS 0 /TON: 4 /TON IS FOR DRY CLIMATE DATA SUBJECT TO CHANGE WITHOUT NOTICE 5

16 *UD2DB9V5VB FURNACE () AND POWER () VS. EXTERNAL STATIC DIP SWITCH S4-3 S ST ND OUTDOOR UNIT SIZE (TONS) *UD2DB9V5VB FURNACE COOLING () AND POWER () VS. EXTERNAL STATIC (See Notes) (3 / TON) DIP SWITCH S3- S3-2 S3-3 S OFF ON OFF ON (0 / TON) OFF ON OFF OFF (4 / TON) OFF ON ON OFF (3 / TON) ON OFF OFF ON (0 / TON) ON OFF OFF OFF (4 / TON) ON OFF ON OFF (3 / TON) OFF OFF OFF ON ** ** (0 / TON) OFF OFF OFF OFF (4 / TON) OFF OFF ON OFF NOTES: "CONTINUOUS FAN " IS THERMOSTAT FAN SWITCH "ON" AND DIP SWITCHS 5 AND 6 "ON".. *FIRST LETTER MAY BE "A" OR "T" 2. **FACTORY. 3. CONTINUOUS FAN : OR COOLING IS APPROXIMATELY % OF SELECTED COOLING VALUE /TON IS RECOMMENDED FOR VARIABLE SPEED APPLICATION FOR COMFORT & HUMID CLIMATE : IS 0 /TON: 4 /TON IS FOR DRY CLIMATE DATA SUBJECT TO CHANGE WITHOUT NOTICE

17 PRODUCT DATA *UD2DA9V5VB FURNACE () AND POWER () VS. EXTERNAL STATIC DIP SWITCH SW 7 SW ST ND OUTDOOR UNIT SIZE (TONS) *UD2DA9V5VB FURNACE COOLING () AND POWER () VS. EXTERNAL STATIC (3 /TON) DIP SWITCH SW SW 2 SW 3 SW OFF ON OFF ON (0 /TON) OFF ON OFF OFF (4 /TON) OFF ON ON OFF (3 /TON) ON OFF OFF ON (0 /TON) ON OFF OFF OFF (4 /TON) ON OFF ON OFF (3 /TON) OFF OFF OFF ON ** ** (0 /TON) OFF OFF OFF OFF (4 /TON) OFF OFF ON OFF NOTES:. * First Letter may be "A" or "T" 2. ** Factory setting 3. Continuous Fan Setting: Heating or Cooling airflow is approximately % of selected Cooling value cfm/ton is recommended for Speed application for COMFORT & HUMID CLIMATE setting; is 0 cfm/ton; 4 cfm/ton is for DRY CLIMATE setting DATA SUBJECT TO CHANGE WITHOUT NOTICE 7

18 PRODUCT DATA WIRING DIAGRAM From Dwg. D35P0 8 DATA SUBJECT TO CHANGE WITHOUT NOTICE

19 SCHEMATIC DIAGRAMS PRODUCT DATA From Dwg. D35P DATA SUBJECT TO CHANGE WITHOUT NOTICE 9

20 From Dwg. D35P0 DATA SUBJECT TO CHANGE WITHOUT NOTICE

21 PRODUCT DATA FIELD WIRING DIAGRAMS REFERENCE THE WIRING SCHEMATIC FOR W2 DIP SWITCH DELAYS. W to W2 JUMPER NOT NEEDED DATA SUBJECT TO CHANGE WITHOUT NOTICE 2

22 PRODUCT DATA FIELD WIRING DIAGRAMS 22 DATA SUBJECT TO CHANGE WITHOUT NOTICE

23 PRODUCT DATA *UD2-9V Outline Drawing (ALL DIMENSIONS ARE IN INCHES) Ø 7/8 HOLE WITH PLUG ELECTRICAL CONNECTION (ALTERNATE) Ø -5/8 HOLE WITH PLUG Ø -5/8 HOLE WITH PLUG MODEL DIM "A" DIM "B" DIM "C" DIM "D" *UD2B060A9V3VB *UD2B080A9V3VB *UD2B00A9V3VB 7-/2" 9-5/8" 6-/4" 6" *UD2C080A9V4VB *UD2C080B9V4VB *UD2C00A9V5VB *UD2C00B9V5VB 2" 3-/6" 9-3/4" 9-/2" *UD2DA9V5VB *UD2DB9V5VB *UD2DA9V5VB 24-/2" 5-5/6" 23-/4" 23" * - The First Letter May Be "A" or "T" DATA SUBJECT TO CHANGE WITHOUT NOTICE 23

24 PRODUCT DATA Since the manufacturer has a policy of continuous product and product data improvement, it reserves the right to change the design and specifications without notice. Technical Literature - Printed in U.S.A. Trane 60 Troup Highway Tyler, TX 75707

XV 80 TDD2B060,080, C100,D120A9V

XV 80 TDD2B060,080, C100,D120A9V Downflow/Horizontal Right or Left 2-Stage Variable Speed Gas-Fired Furnace XV 80 TDD2B060,080, C100,D120A9V Two-Stage Fan Assisted Combustion System PUB. NO. 22-1673-10 General Features NATURAL GAS MODELS

More information

80 TDD2B060,080, C100,D120A9V

80 TDD2B060,080, C100,D120A9V Downflow/Horizontal Right or Downflow/Horizontal Left 2-Stage, Variable Speed Gas-Fired Furnace XV 80 TDD2B060,080, C100,D120A9V Two-Stage Fan Assisted Combustion System TDD-D-1 PUB. NO. 22-1673-07 General

More information

XC 95m. Communicating Upflow/Horizontal Left Downflow/Horizontal Right Direct/Non-Direct Vent Variable Speed, Modulating Condensing Gas Furnace

XC 95m. Communicating Upflow/Horizontal Left Downflow/Horizontal Right Direct/Non-Direct Vent Variable Speed, Modulating Condensing Gas Furnace TUHM Communicating Upflow/Horizontal Left Downflow/Horizontal Right Direct/Non-Direct Vent Variable Speed, Modulating Condensing Gas Furnace XC 95m TUHMB060ACV3VA, TDHMB060BCV3VA TUHMB080ACV3VA, TDHMB080ACV3VA

More information

XC 95m. Communicating Upflow/Horizontal Left Downflow/Horizontal Right Direct/Non-Direct Vent Variable Speed, Modulating Condensing Gas Furnace

XC 95m. Communicating Upflow/Horizontal Left Downflow/Horizontal Right Direct/Non-Direct Vent Variable Speed, Modulating Condensing Gas Furnace TUHM Communicating Upflow/Horizontal Left Downflow/Horizontal Right Direct/Non-Direct Vent Variable Speed, Modulating Condensing Gas Furnace XC 95m TUHMB060ACV3VB, TDHMB060BCV3VB TUHMB080ACV3VB, TDHMB080ACV3VB

More information

XC 95. Communicating Only Upflow/Horizontal Left Downflow/Horizontal Right Direct/Non-Direct Vent 3 Stage Gas Furnace with. Variable Speed Inducer

XC 95. Communicating Only Upflow/Horizontal Left Downflow/Horizontal Right Direct/Non-Direct Vent 3 Stage Gas Furnace with. Variable Speed Inducer TUH3-AC-V Communicating Only Upflow/Horizontal Left Downflow/Horizontal Right Direct/Non-Direct Vent 3 Stage Gas Furnace with Speed Inducer XC 95 TUH3B060ACV3VA, TDH3B060ACV3VA TUH3B080ACV3VA, TDH3B080ACV3VA

More information

Upflow/ Horizontal Left/Right, Downflow Two Stage Condensing Gas Fired Furnace

Upflow/ Horizontal Left/Right, Downflow Two Stage Condensing Gas Fired Furnace Product Data Upflow/ Horizontal Left/Right, Downflow Two Condensing Gas Fired Furnace Upflow, Convertible to HorizontalRight or HorizontalLeft S9V2B040U3PSBB S9V2B060U3PSBB S9V2B060U4PSBB S9V2B080U3PSBB

More information

Upflow/ Horizontal Left, Downflow/ Horizontal Right Variable Speed Two Stage Condensing Gas-Fired Furnace Freedom 95

Upflow/ Horizontal Left, Downflow/ Horizontal Right Variable Speed Two Stage Condensing Gas-Fired Furnace Freedom 95 *UHA9VV Upflow/ Horizontal Left, Downflow/ Horizontal Right Speed Two Stage Condensing GasFired Furnace Freedom 95 AUH2B060A9V3VA, ADH2B060A9V3VA AUH2B080A9V3VA, ADH2B080A9V3VA AUH2C100A9V4VA, ADH2C100A9V4VA

More information

XP80 / XV80 Highboy Vertical THV1M087A936,V3,SA THV1M087A948,V5,SA

XP80 / XV80 Highboy Vertical THV1M087A936,V3,SA THV1M087A948,V5,SA TDD-D-1 Vertical boy, boy Front Flue, boy Rear Flue, Downflow/Horizontal Oil-Fired Furnace XP80 / XV80 boy Vertical THV1M087A936,V3,SA THV1M087A948,V5,SA Downflow/Horizontal Front Flue TDF1M087A936,V3,SA

More information

95G2E PRODUCT SPECIFICATIONS 95% TWO-STAGE CONSTANT TORQUE GAS FURNACES CONTROLS VENTING CONFIGURATIONS HEAT EXCHANGER DESIGN INSTALLATION FEATURES

95G2E PRODUCT SPECIFICATIONS 95% TWO-STAGE CONSTANT TORQUE GAS FURNACES CONTROLS VENTING CONFIGURATIONS HEAT EXCHANGER DESIGN INSTALLATION FEATURES 95G2E PRODUCT SPECIFICATIONS 95% TWO-STAGE CONSTANT TORQUE GAS FURNACES FORM NO. 95G2E-100 (04/2016) CONTROLS Two stage gas valve Integrated ignition and fan control Control board retains last ten (10)

More information

Multi-Position, Multi-Speed Gas Furnaces

Multi-Position, Multi-Speed Gas Furnaces Heating Input: 40,000 140,000 BTU/h / Multi-Position, Multi-Speed Gas Furnaces 80% AFUE Standard Features Dual-diameter tubular heat exchanger Two-stage gas valve control technology allows installer to

More information

GMS9/GCS9 SERIES 93% AFUE

GMS9/GCS9 SERIES 93% AFUE / SERIES 93% AFUE MULTI-POSITION, SINGLE-STAGE/MULTI-SPEED GAS FURNACE HEATING CAPACITY: 46,000 115,000 BTU/H Standard Features Corrosion-resistant, aluminized-steel tubular heat exchanger and stainless-steel

More information

GMH95/GCH9 PRODUCT SPECIFICATIONS 95%/93% AFUE HEAT REPLACEMENT MULTI-POSITION, TWO-STAGE (CONVERTIBLE), MULTI-SPEED GAS FURNACE

GMH95/GCH9 PRODUCT SPECIFICATIONS 95%/93% AFUE HEAT REPLACEMENT MULTI-POSITION, TWO-STAGE (CONVERTIBLE), MULTI-SPEED GAS FURNACE / 95%/93% AFUE MULTI-POSITION, TWO-STAGE (CONVERTIBLE), MULTI-SPEED GAS FURNACE HEATING INPUT: 46,000 115,000 BTU/H LIFETIME HEAT EXCHANGER LIMITED WARRANTY 10 YEAR HEAT REPLACEMENT CXCHANGER WARRANTY

More information

A962E PRODUCT SPECIFICATIONS TWO STAGE HIGH EFFICIENCY CONSTANT TORQUE GAS FURNACE CONTROLS VENTING CONFIGURATIONS HEAT EXCHANGER DESIGN

A962E PRODUCT SPECIFICATIONS TWO STAGE HIGH EFFICIENCY CONSTANT TORQUE GAS FURNACE CONTROLS VENTING CONFIGURATIONS HEAT EXCHANGER DESIGN A962E PRODUCT SPECIFICATIONS TWO STAGE HIGH EFFICIENCY CONSTANT TORQUE GAS FURNACE FORM NO. A962E-100 (04/2018) CONTROLS Two stage gas valve Integrated ignition and fan control System Sentry control retains

More information

A95-2V. 95% Gas Furnaces Two-Stage Variable Speed HEAT EXCHANGER DESIGN CONFIGURATIONS

A95-2V. 95% Gas Furnaces Two-Stage Variable Speed HEAT EXCHANGER DESIGN CONFIGURATIONS Two- Variable Speed HEAT EXCHANGER DESIGN 409 Stainless steel primary heat exchanger material AL29-4C Stainless steel secondary heat exchanger Non-welded crimped S-curve primary heat exchanger design for

More information

GUH 95 Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

GUH 95 Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS TECHNICAL SPECIFICATIONS GUH 95 Series Two Stage, Variable Speed, Condensing Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 95.1 AFUE Input 60,000-120,000 Btuh The high efficiency upflow gas

More information

KG7T (E and N Series)

KG7T (E and N Series) TECHNICAL SPECIFICATIONS KG7T (E and N Series) Two Stage, Fixed Speed ECM, Condensing Upflow and Downflow Gas Furnaces Induced Draft - 96% AFUE Input 60,000-115,000 Btuh The high efficiency upflow gas

More information

FG7T (E and N Series)

FG7T (E and N Series) TECHNICAL SPECIFICATIONS FG7T (E and N Series), Smartlite Two Stage, Fixed Speed ECM, High Efficiency Upflow and Downflow Gas Furnaces Induced Draft - 96% AFUE Input 60,000-115,000 Btuh The high efficiency

More information

Product Data. that this product meets the S 95% AFUE S Two -stage operation

Product Data. that this product meets the S 95% AFUE S Two -stage operation DIRECT VENT 4 -WAY MULTIPOISE CONDENSING GAS FURNACE 95% DOWNFLOW / HORIZONTAL ORIENTATIONS 93.5% UPFLOW ORIENTATION 95% Variable Speed Two -Stage Heating Furnace FLEXIBILITY S Supports two -stage cooling

More information

UPFLOW/ HORIZONTAL GAS FURNACE

UPFLOW/ HORIZONTAL GAS FURNACE FORM NO. GFJ-542 UPFLOW/ HORIZONTAL GAS FURNACE Features 80% residential Gas Furnace CSA certified 3 way multi poise design UF / HZ 7 Segment LED all units Direct Spark Ignition for reliability and longevity

More information

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama 58HDX COMFORT 95 DIRECT OR NON---DIRECT VENT CONDENSING GAS FURNACE

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama 58HDX COMFORT 95 DIRECT OR NON---DIRECT VENT CONDENSING GAS FURNACE COMFORT 95 DIRECT OR NON---DIRECT VENT 4 --- WAY MULTIPOISE CONDENSING GAS FURNACE 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal FLEXIBILITY S Dual certified venting (1 or 2 pipes) Direct

More information

G8MVL. Product Specifications

G8MVL. Product Specifications 80% Variable Speed, Two Stage Heating Furnace EASIER TO SELL 80% AFUE Supports two stage cooling units Flame roll out sensors standard Category I venting Blocked vent switch Dehumidification feature in

More information

W801S (Downflow) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. )

W801S (Downflow) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. ) FORM NO. G66-547 REV. 4 Supersedes Form No. G66-536 Rev. 3 DOWNF GAS FURNACE Features 80% residential Gas Furnace CSA certified 7 Segment LED all units Direct spark ignition for reliability and longevity

More information

Rheem Prestige Series Communicating Two-Stage Variable Speed Upflow/Horizontal Gas Furnace

Rheem Prestige Series Communicating Two-Stage Variable Speed Upflow/Horizontal Gas Furnace Gas Furnaces Rheem Prestige Series Communicating Two-Stage Variable Speed Upflow/Horizontal Gas Furnace R802V- Upflow/Horizontal Series 80% A.F.U.E. Input Rates 50-125 kbtu A.F.U.E. (Annual Fuel Utilization

More information

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa) N8MXL Product Specifications 80% ECM Single Stage Heating Furnace EASIER TO SELL 80% AFUE Flame roll out sensors standard Category I venting Blocked vent switch 24 VAC humidifier terminal Electronic air

More information

80% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES

80% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES FORM NO. G66-495 Supersedes Form No. P66-765 Rev. 3 80PS- SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] 80% A.F.U.E. UPF/ HORIZONTAL GAS FURNACES The WeatherKing line of upflow/horizontal

More information

PRODUCT SPECIFICATIONS GMS8/GDS8/GHS8 SERIES 80% AFUE MULTI-POSITION, SINGLE-STAGE/MULTI-SPEED GAS FURNACE

PRODUCT SPECIFICATIONS GMS8/GDS8/GHS8 SERIES 80% AFUE MULTI-POSITION, SINGLE-STAGE/MULTI-SPEED GAS FURNACE GMS8/GDS8/GHS8 SERIES 80% AFUE MULTI-POSITION, SINGLE-STAGE/MULTI-SPEED GAS FURNACE HEATING CAPACITY: 45,000 1,000 BTUH The GMS8/GDS8/GHS8 single-stage, multi-speed gas furnaces offer installation versatility.

More information

W801S (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. )

W801S (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. ) FORM NO. G66-542 REV. 4 Supersedes Form No. G66-536 Rev. 3 W801S (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. ) UPFLOW/ HORIZONTAL GAS FURNACES Features

More information

G23 Bulletin # September 1998 Supersedes June 1995

G23 Bulletin # September 1998 Supersedes June 1995 ENGINEERING DATA ELITE 80Z UP-FLOW GAS FURNACES *80.0% to 80.8% A.F.U.E. 50,000 to 150,000 Btuh (14.7 to 44.0 kw) Gas Heating Input 1 thru 6 Tons (3.5 thru 21.1 kw) Nominal Add-On Cooling *Isolated Combustion

More information

Ruud Achiever Plus Series Upflow/Horizontal Gas Furnace

Ruud Achiever Plus Series Upflow/Horizontal Gas Furnace Gas Furnaces Ruud Achiever Plus Series Upflow/Horizontal Gas Furnace R802P- Upflow/Horizontal Series 80% A.F.U.E. Input Rates 50-150 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance

More information

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa) 92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 92.1% AFUE, all models all positions, California NOx approved Certified to leak 2% or less of nominal air conditioning CFM delivered when pressurized

More information

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa) 95.5% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 95.5% AFUE, all models all positions, California NOx approved Certified to leak 2% or less of nominal air conditioning CFM delivered when pressurized

More information

Modular Variable Speed Air Handlers

Modular Variable Speed Air Handlers Modular Variable Speed Air Handlers Convertible Variable Speed Communicating Air Handlers - 1 1/2-5 Ton 4TEE3C01A1000A 4TEE3C02A1000A 4TEE3C03A1000A 4TEE3C04A1000A 4TEE3C05A1000A 4TEE3C06A1000A 4TEE3C07A1000A

More information

FORM NO. GTZ-542 Supersedes Form No. GTZ-503 Rev. 1

FORM NO. GTZ-542 Supersedes Form No. GTZ-503 Rev. 1 FORM NO. GTZ-542 Supersedes Form No. GTZ-503 Rev. 1 TZ80MSS (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] UPFLOW/ HORIZONTAL GAS FURNACES Features 80% residential

More information

Rheem Classic Series Upflow/Horizontal Gas Furnace

Rheem Classic Series Upflow/Horizontal Gas Furnace Gas Furnaces Rheem Classic Series Upflow/Horizontal Gas Furnace R801P- Upflow/Horizontal Series 80% A.F.U.E. Input Rates 50-150 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance

More information

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa) 92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 92.1% AFUE, all models all positions, California NOx approved Certified to leak 2% or less of nominal air conditioning CFM delivered when pressurized

More information

FG7S (C and L Series)

FG7S (C and L Series) TECHNICAL SPECIFICATIONS FG7S (C and L Series) High Efficiency/Direct Vent or Non Direct Vent Single Stage Condensing Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 92.1 AFUE Input 38,000-120,000

More information

Table of Contents GF801U Series

Table of Contents GF801U Series FORM NO. GSC-520 GF801U SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] 80% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES The Sure Comfort line of upflow/horizontal gas furnaces are designed

More information

Up to 96% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL

Up to 96% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL N9MSE Product Specifications Up to 96% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL Up to 96% AFUE in upflow and horizontal positions, Up to 96% AFUE in downflow positions California NOx approved

More information

Product Data. S Variable-speed ECM blower motor. S Two heating stages. S Humidity control when using a humidity sensing thermostat

Product Data. S Variable-speed ECM blower motor. S Two heating stages. S Humidity control when using a humidity sensing thermostat PG8MVA PG8JVA 4 --- WAY MULTIPOISE INDUCED---COMBUSTION GAS FURNACE INPUT CAPACITIES: 70,000 thru 135,000 Btuh SERIES A Product Data multipoise design, through -the-furnace downflow venting, 13 different

More information

GF802D SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (U.S. & Canadian Models)

GF802D SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (U.S. & Canadian Models) FORM NO. GSC-515 GF802D SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (U.S. & Canadian Models) TWO STAGE DOWNFLOW GAS FURNACES The Sure Comfort 2-Stage line of downflow gas furnaces

More information

TZ80MSX (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu [15 to 37 kw] FORM NO. GTZ-544 Supersedes Form No. GTZ-503 Rev.

TZ80MSX (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu [15 to 37 kw] FORM NO. GTZ-544 Supersedes Form No. GTZ-503 Rev. FORM NO. GTZ-544 Supersedes Form No. GTZ-503 Rev. 1 UPFLOW/ HORIZONTAL GAS FURNACES Features 80% residential Gas Furnace CSA certified 3 way multi poise design UF / HZ 7 Segment LED all units Direct Spark

More information

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa) 92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 92.1% AFUE, all models all positions, California NOx approved Certified to leak 2% or less of nominal air conditioning CFM delivered when pressurized

More information

VG7S (D and M Series) High Efficiency, Single Stage Condensing Upflow/Horizontal and Downflow Gas Furnace Models 95.0 AFUE 38, ,000 Btuh Input

VG7S (D and M Series) High Efficiency, Single Stage Condensing Upflow/Horizontal and Downflow Gas Furnace Models 95.0 AFUE 38, ,000 Btuh Input TECHNICAL SPECIFICATIONS VG7S (D and M Series) High Efficiency, Single Stage Condensing Upflow/Horizontal and Downflow Gas Furnace Models 95.0 AFUE 38,000-120,000 Btuh Input The high efficiency upflow

More information

GAS FURNACES CLASSIC SERIES SUPER QUIET % A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES

GAS FURNACES CLASSIC SERIES SUPER QUIET % A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES FORM NO. G11-485 REV. 5 Supersedes Form No. G11-485 Rev. 4 GAS FURNACES RGPN- SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] (U.S. & Canadian Models) ISO 9001:2000 Annual Fuel

More information

Rheem Classic Series Upflow/Horizontal Gas Furnace

Rheem Classic Series Upflow/Horizontal Gas Furnace THIS MODEL Air Gas Furnaces Rheem Classic Series Upflow/Horizontal Gas Furnace R801S- (Upflow/Horizontal) Series 80% A.F.U.E. Input Rates 50-150 kbtu ENER UIDE Annual Fuel Utilization Efficiency - AFUE

More information

N9MSB. PS 92 Product Specifications. 92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL /2/17

N9MSB. PS 92 Product Specifications. 92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL /2/17 92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 92.1% AFUE all models in all positions California NOx approved Certified to leak 2% or less of nominal air conditioning CFM delivered when pressurized

More information

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa) 95.5% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 95.5% AFUE, all models all positions, California NOx approved Certified to leak 2% or less of nominal air conditioning CFM delivered when pressurized

More information

Rheem Classic Series Downflow Gas Furnace

Rheem Classic Series Downflow Gas Furnace Gas Furnaces Rheem Classic Series Downflow Gas Furnace R801S (Downflow) Series 80% A.F.U.E. Input Rates 50-150 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department

More information

W801T (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu (80% A.F.U.E. )

W801T (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu (80% A.F.U.E. ) FORM NO. G66-544 REV. 4 Supersedes Form No. G66-536 Rev. 3 W801T (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu (80% A.F.U.E. ) UPFLOW/ HORIZONTAL GAS FURNACES Features 80% residential

More information

95G1-E. Aluminized steel primary heat exchanger with crimped non-welded construction AL 29-4C Stainless steel secondary heat exchanger

95G1-E. Aluminized steel primary heat exchanger with crimped non-welded construction AL 29-4C Stainless steel secondary heat exchanger Single Stage - High Efficiency (Constant Torque) Motor 95% Gas Furnaces Features and Benefits CONFIGURATIONS Upflow / Horizontal Downflow 95G1-E Form No. D95G1-E-100 (10/2011) HEAT EXCHANGER DESIGN Aluminized

More information

95G1E PRODUCT SPECIFICATIONS SINGLE STAGE CONSTANT TORQUE MOTOR VENTING INSTALLATION FEATURES WARRANTY CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER

95G1E PRODUCT SPECIFICATIONS SINGLE STAGE CONSTANT TORQUE MOTOR VENTING INSTALLATION FEATURES WARRANTY CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER 95G1E PRODUCT SPECIFICATIONS SINGLE STAGE CONSTANT TORQUE MOTOR FORM NO. 95G1E-100 (04/2016) VENTING Designed certified for direct (2-pipe) and non direct (1-pipe) applications Easily vented with PVC pipe

More information

Cooling Capacity Dimensions H x W x D CFM range Inches in. w.c. (125 Pa)

Cooling Capacity Dimensions H x W x D CFM range Inches in. w.c. (125 Pa) 80% Single Stage Heating Furnace EASIER TO SELL 80% AFUE Flame roll out senss standard Categy I venting Blocked vent switch Louvered do 24 VAC and 115 VAC humidifier terminal Electronic air cleaner terminal

More information

Rheem Classic Plus Series Upflow/Horizontal Gas Furnace

Rheem Classic Plus Series Upflow/Horizontal Gas Furnace Gas Furnaces Rheem Classic Plus Series Upflow/Horizontal Gas Furnace R801T- Upflow/Horizontal Series 80% A.F.U.E. Input Rates 50-125 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance

More information

Rheem Classic Plus Series Upflow/Horizontal Gas Furnace

Rheem Classic Plus Series Upflow/Horizontal Gas Furnace Gas Furnaces Rheem Classic Plus Series Upflow/Horizontal Gas Furnace R801T- Upflow/Horizontal Series 80% A.F.U.E. Input Rates 50-125 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance

More information

80 PLUS A.F.U.E. UPFLOW/HORIZONTAL GAS FURNACES

80 PLUS A.F.U.E. UPFLOW/HORIZONTAL GAS FURNACES FORM NO. G66-478 REV. 5 Supersedes Form No. G66-478 Rev. 4 80PJ SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] 80 PLUS A.F.U.E. UPF/HORIZONTAL GAS FURNACES Features The WeatherKing

More information

95% Gas Furnaces. Single Stage - High Efficiency (Constant Torque) Motor. Features and Benefits 95G1-E CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER

95% Gas Furnaces. Single Stage - High Efficiency (Constant Torque) Motor. Features and Benefits 95G1-E CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER 95G1-E Features and Benefits CONFIGURATIONS 95% Gas Furnaces Single Stage - High Efficiency (Constant Torque) Motor Upflow / Horizontal Downflow Form No. R95G1-E-100 (01/2012) HEAT EXCHANGER DESIGN Aluminized

More information

Cooling Capacity Dimensions H x W x D CFM range Inches in. w.c. (125 Pa)

Cooling Capacity Dimensions H x W x D CFM range Inches in. w.c. (125 Pa) 80% Single Stage Heating Furnace EASIER TO SELL 80% AFUE Flame roll out senss standard Categy I venting Blocked vent switch Louvered do 24 VAC and 115 VAC humidifier terminal Electronic air cleaner terminal

More information

WFSR. Product Specifications 95.5 AFUE GAS FURNACE MULTIPOISE DESIGN UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS) Heat Exchangers Warranty

WFSR. Product Specifications 95.5 AFUE GAS FURNACE MULTIPOISE DESIGN UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS) Heat Exchangers Warranty 95.5 AFUE GAS FURNACE MULTIPOISE DESIGN WFSR Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification for individual products, go to

More information

DUAL COMFORT CONTROL TWO-STAGE DOWNFLOW/HORIZONTAL GAS FURNACES WITH

DUAL COMFORT CONTROL TWO-STAGE DOWNFLOW/HORIZONTAL GAS FURNACES WITH FORM NO. GSC-531 REV. 1 Supersedes Form No. GSC-488 Rev. 7 GF902D SERIES Models with Input Rates from 60 to 120 kbtu [17.58 to 35.17 kw] (All Models 92% A.F.U.E. or Above) TWO-STAGE DOWNFLOW/HORIZONTAL

More information

96G1E PRODUCT SPECIFICATIONS SINGLE STAGE CONSTANT TORQUE MOTOR VENTING INSTALLATION FEATURES WARRANTY CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER

96G1E PRODUCT SPECIFICATIONS SINGLE STAGE CONSTANT TORQUE MOTOR VENTING INSTALLATION FEATURES WARRANTY CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER 96G1E PRODUCT SPECIFICATIONS SINGLE STAGE CONSTANT TORQUE MOTOR FORM NO. 96G1E-100 (04/2018) VENTING Designed certified for direct (2-pipe) and non direct (1-pipe) applications Easily vented with PVC pipe

More information

GAS FURNACES ACHIEVER SERIES SUPER QUIET % A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES

GAS FURNACES ACHIEVER SERIES SUPER QUIET % A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES FORM NO. G22-485 REV. 4 Supersedes Form No. G22-485 Rev. 3 GAS FURNACES UGPN- SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] (U.S. & Canadian Models) Annual Fuel Utilization

More information

Ruud Ultra Series Communicating Two-Stage Variable Speed Downflow Gas Furnace

Ruud Ultra Series Communicating Two-Stage Variable Speed Downflow Gas Furnace Gas Furnaces Ruud Ultra Series Communicating Two-Stage Variable Speed Downflow Gas Furnace U802V Downflow Series 80% A.F.U.E. Input Rates 75-125 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated

More information

WFAR. Product Specifications 92.1 AFUE GAS FURNACE MULTIPOISE DESIGN UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS) Heat Exchangers Warranty

WFAR. Product Specifications 92.1 AFUE GAS FURNACE MULTIPOISE DESIGN UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS) Heat Exchangers Warranty 92.1 AFUE GAS FURNACE MULTIPOISE DESIGN WFAR Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification for individual products, go to

More information

WFEL. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design

WFEL. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design 80% AFUE GAS FURNACE Multipoise Design WFEL Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification for individual products, go to www.ahridirectory.org.

More information

TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY

TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY TECHNICAL SPECIFICATIONS KG7S (C and L Series) High Efficiency / Direct Vent or Non Direct Vent Condensing Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 92. AFUE Input 38,000-20,000 Btuh

More information

GAS FURNACES II 80.0% 81.4% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES SILHOUETTE

GAS FURNACES II 80.0% 81.4% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES SILHOUETTE FORM NO. G22-448 REV. 10 Supersedes Form No. G22-448 Rev. 9 GAS FURNACES UGPH- SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] (U.S. & Canadian Models) Annual Fuel Utilization

More information

Rheem Classic Plus Series Upflow/Horizontal Ultra Low NOx Gas Furnace

Rheem Classic Plus Series Upflow/Horizontal Ultra Low NOx Gas Furnace Gas Furnaces Rheem Classic Plus Series Upflow/Horizontal Ultra Low NOx Gas Furnace R801T- Upflow/Horizontal Series 80% A.F.U.E. Input Rates 50-100 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated

More information

WFEL. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design

WFEL. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design 80% AFUE GAS FURNACE Multipoise Design WFEL Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification for individual products, go to www.ahridirectory.org.

More information

OIL FIRED UPFLOW FURNACE SPECIFICATIONS THV1C072A948SA (BECKETT AFG)

OIL FIRED UPFLOW FURNACE SPECIFICATIONS THV1C072A948SA (BECKETT AFG) MODEL NO. THV1C072A948SA (BECKETT AFG) THV1C072A9V4SA (BECKETT AFG) HEATING CAPACITY High Fire Med Fire Low Fire High Fire Med Fire Low Fire HEAT INPUT RATE (BTUH) 106,250 85,000 70,000 106,250 85,000

More information

80 PLUS A.F.U.E. UPFLOW/HORIZONTAL GAS FURNACES

80 PLUS A.F.U.E. UPFLOW/HORIZONTAL GAS FURNACES FORM NO. G66-478 REV. 1 Supersedes Form No. G66-478 Rev. 0 80 PLUS A.F.U.E. UPF/HORIZONTAL GAS FURNACES Features The WeatherKing line of upflow/horizontal gas furnaces are designed for utility rooms, closets,

More information

DM80SS / DD80SS. Single-Stage, Multi-Speed Gas Furnaces 80% AFUE Heating Input: 40, ,000 BTU/h

DM80SS / DD80SS. Single-Stage, Multi-Speed Gas Furnaces 80% AFUE Heating Input: 40, ,000 BTU/h / Single-Stage, Multi-Speed Gas Furnaces 80% AFUE Heating Input: 40,000 140,000 BTU/h Contents Nomenclature...2 Product Specifications...3 Dimensions...5 Airflow Data...8 Wiring Diagram...10 Accessories...11

More information

VMS8/VDS8. Single-Stage, Single Speed, Multi-Position Gas Furnace 80% AFUE. Heating Input : 40, ,000 BTU/h

VMS8/VDS8. Single-Stage, Single Speed, Multi-Position Gas Furnace 80% AFUE. Heating Input : 40, ,000 BTU/h / Heating Input : 40,000 100,000 BTU/h Single-Stage, Single Speed, Multi-Position Gas Furnace 80% AFUE Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 5 Airflow Data... 8 Wiring Diagrams...

More information

W801T (Downflow) Series Models with Input Rates from 75 to 125 kbtu [15 to 37 kw] (80% A.F.U.E. )

W801T (Downflow) Series Models with Input Rates from 75 to 125 kbtu [15 to 37 kw] (80% A.F.U.E. ) FORM NO. G66-549 REV. 3 Supersedes Form No. G66-536 Rev. 3 DOWNFLOW GAS FURNACE Features 80% residential Gas Furnace CSA certified 7 Segment LED all units Direct Spark Ignition System for reliability and

More information

WFAR. Product Specifications 92.1 AFUE GAS FURNACE MULTIPOISE DESIGN

WFAR. Product Specifications 92.1 AFUE GAS FURNACE MULTIPOISE DESIGN 92.1 AFUE GAS FURNACE MULTIPOISE DESIGN WFAR Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification for individual products, go to

More information

GAS FURNACES QUIET 80 80% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES

GAS FURNACES QUIET 80 80% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES FORM NO. G11-486 REV. 3 Supersedes Form No. G11-486 Rev. 2 GAS FURNACES RGPP- SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] (U.S. & Canadian Models) ISO 9001:2000 Annual Fuel

More information

80% A.F.U.E. DOWNFLOW GAS FURNACES

80% A.F.U.E. DOWNFLOW GAS FURNACES FORM NO. G66-496 REV. 5 Supersedes Form No. G66-496 Rev. 4 RGLS- SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] (U.S. & Canadian Models) 80% A.F.U.E. DOWNF GAS FURNACES The

More information

Easily removable slide-out blower design PSC multi-speed permanently lubricated blower motor for low maintenance and optimum efficiency

Easily removable slide-out blower design PSC multi-speed permanently lubricated blower motor for low maintenance and optimum efficiency Gas Furnaces PRODUCT SPECIFICATIONS INSTALLATION OPTIONS A vailable in Upflow/Horizontal and Counterflow models 80% AFUE 44,000 to 32,000 Btuh Input.5 to 5 Tons Add-On Cooling HEAT EXCHANGER A luminized

More information

FG7T (A and K Series)

FG7T (A and K Series) TECHNICAL SPECIFICATIONS FGT (A and K Series) Two Stage, Variable Speed, High Efficiency Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 80 + AFUE Input 60,000-140,000 Btuh The high efficiency

More information

DD80HS. Two-Stage, Convertible Multi-Speed Gas Furnace 80% AFUE. Heating Input: 40, ,000 BTU/h

DD80HS. Two-Stage, Convertible Multi-Speed Gas Furnace 80% AFUE. Heating Input: 40, ,000 BTU/h Two-Stage, Convertible Multi-Speed Gas Furnace 80% AFUE Heating Input: 40,000 100,000 BTU/h Contents Nomenclature...2 Product Specifications...3 Dimensions...4 Airflow Data...5 Wiring Diagram...7 Accessories...8

More information

KG7T (C and L Series)

KG7T (C and L Series) TECHNICAL SPECIFICATIONS KG7T (C and L Series) Two Stage, Fixed Speed ECM, Condensing Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 95.1 AFUE Input 60,000-120,000 Btuh The high efficiency

More information

TECHNICAL GUIDE MODELS: G8T-UP 80 AFUE UPFLOW/HORIZONTAL GAS-FIRED FURNACES DESCRIPTION WARRANTY FEATURES Rev.

TECHNICAL GUIDE MODELS: G8T-UP 80 AFUE UPFLOW/HORIZONTAL GAS-FIRED FURNACES DESCRIPTION WARRANTY FEATURES Rev. TECHNICAL GUIDE MODELS: G8T-UP 80 AFUE UPFLOW/HORIZONTAL GAS-FIRED FURNACES 40-130 MBH INPUT HIGH-EFFICIENCY INDUCED COMBUSTION EFFICIENCY RATING CERTIFIED This product was manufactured in a plant whose

More information

TECHNICAL GUIDE MODELS: P4HU 80 AFUE MULTI-POSITION GAS-FIRED FURNACES DESCRIPTION. WARRANTY 20-year limited warranty on the heat exchanger.

TECHNICAL GUIDE MODELS: P4HU 80 AFUE MULTI-POSITION GAS-FIRED FURNACES DESCRIPTION. WARRANTY 20-year limited warranty on the heat exchanger. 036-21047-001 Rev. A (4/00) DESCRIPTION These high efficiency, compact units employ induced combustion, reliable hot surface ignition and high heat transfer aluminized tubular heat exchangers. The units

More information

TECHNICAL GUIDE 80 AFUE DOWNFLOW GAS-FIRED FURNACES MODELS: G8T-DN DESCRIPTION WARRANTY FEATURES Rev. B (0303)

TECHNICAL GUIDE 80 AFUE DOWNFLOW GAS-FIRED FURNACES MODELS: G8T-DN DESCRIPTION WARRANTY FEATURES Rev. B (0303) TECHNICAL GUIDE 80 AFUE DOWNFLOW GAS-FIRED FURNACES MODELS: G8T-DN 40-130 MBH INPUT HIGH-EFFICIENCY INDUCED COMBUSTION DESCRIPTION These high efficiency, dedicated downflow compact units employ induced

More information

95% Gas Furnaces A95-1E. Single Stage - High Efficiency (Constant Torque) Motor. Features and Benefits CONFIGURATIONS

95% Gas Furnaces A95-1E. Single Stage - High Efficiency (Constant Torque) Motor. Features and Benefits CONFIGURATIONS A95-1E 95% Gas Furnaces Single Stage - High Efficiency (Constant Torque) Motor Features and Benefits CONFIGURATIONS Upflow / Horizontal Downflow Form No. JA95-1E-100 (10/2011) HEAT EXCHANGER DESIGN Stainless

More information

TSTAT0101SC Recommended (sold separately)

TSTAT0101SC Recommended (sold separately) Up to 96% AFUE, Communicating, Two Stage Gas Furnace EASIER TO SELL Up to 96% AFUE, all models, all positions California NOx approved All Models have earned the ENERGY STAR Two stage heating operation

More information

KG7T (C and L Series)

KG7T (C and L Series) TECHNICAL SPECIFICATIONS KG7T (C and L Series) Two Stage, Fixed Speed ECM, Condensing Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 95.1 AFUE Input 60,000-120,000 Btuh The high efficiency

More information

Rheem Value Series Downflow Gas Furnace

Rheem Value Series Downflow Gas Furnace THIS MODEL 80.0% 78% 82% 88% 97% Air Gas Furnaces Rheem Value Series Downflow Gas Furnace RGLS- Series 80% A.F.U.E. Input Rates 50-150 kbtu ENER UIDE Annual Fuel Utilization Efficiency - AFUE MID A.F.U.E.

More information

F8MTL. Product Specifications

F8MTL. Product Specifications 80% Two Stage Heating Furnace EASIER TO SELL 80% AFUE Suppts two stage cooling units Flame roll out senss standard Categy I venting Blocked vent switch Dehumidification feature in cooling 24 VAC and 115

More information

AMS8 / ADSS8. Single-Stage Multi-Speed Gas Furnaces 80% AFUE. Heating Input: 40, ,000 BTU/h

AMS8 / ADSS8. Single-Stage Multi-Speed Gas Furnaces 80% AFUE. Heating Input: 40, ,000 BTU/h / ADSS8 Heating Input: 40,000 140,000 BTU/h Single-Stage Multi-Speed Gas Furnaces 80% AFUE Contents Nomenclature...2 Product Specifications...3 Dimensions...5 Airflow Data...7 Wiring Diagrams...10 Accessories...11

More information

G9MXE. Product Specifications

G9MXE. Product Specifications Up to 96% AFUE, Single Stage, ECM Gas Furnace EASIER TO SELL Up to 96% AFUE, all models all positions California NOx approved Select models earn the ENERGY STAR (See below, indicated with check mark.)

More information

G9MXE. Product Specifications

G9MXE. Product Specifications Up to 96% AFUE, Single Stage, ECM Gas Furnace EASIER TO SELL Up to 96% AFUE, all models all positions California NOx approved Select models earn the ENERGY STAR (See below, indicated with check mark.)

More information

GAS FURNACES CLASSIC SERIES SUPER QUIET 80 80% A.F.U.E. DOWNFLOW GAS FURNACES

GAS FURNACES CLASSIC SERIES SUPER QUIET 80 80% A.F.U.E. DOWNFLOW GAS FURNACES FORM NO. G11-487 REV. 1 Supersedes Form No. G11-487 Rev. 8 GAS FURNACES RGLN- SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] (U.S. & Canadian Models) Annual Fuel Utilization

More information

KG7S (A and K Series)

KG7S (A and K Series) TECHNICAL SPECIFICATIONS KG7S (A and K Series) High Efficiency Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 80+ AFUE Input 45,000-126,000 Btuh The high efficiency gas furnace may be installed

More information

GMH8/GDH8. Two-Stage Convertible Multi-Speed Gas Furnaces 80% AFUE

GMH8/GDH8. Two-Stage Convertible Multi-Speed Gas Furnaces 80% AFUE / Two-Stage Convertible Multi-Speed Gas Furnaces 80% AFUE Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 5 Airflow Data... 7 Wiring Diagram... 10 Accessories... 11 Minimum Filter

More information

TECHNICAL GUIDE MODELS: P4DN 80 AFUE DOWNFLOW GAS-FIRED FURNACES DESCRIPTION. WARRANTY 20-year limited warranty on the heat exchanger.

TECHNICAL GUIDE MODELS: P4DN 80 AFUE DOWNFLOW GAS-FIRED FURNACES DESCRIPTION. WARRANTY 20-year limited warranty on the heat exchanger. 036-21053-001 Rev. A (4/00) DESCRIPTION These high efficiency, dedicated downflow compact units employ induced combustion, reliable hot surface ignition and high heat transfer tubular heat exchangers.

More information

92G1 PRODUCT SPECIFICATIONS SINGLE STAGE GAS FURNACE CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER CABINET DESIGN AIR DELIVERY SYSTEM CONTROLS VENTING

92G1 PRODUCT SPECIFICATIONS SINGLE STAGE GAS FURNACE CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER CABINET DESIGN AIR DELIVERY SYSTEM CONTROLS VENTING 92G1 PRODUCT SPECIFICATIONS SINGLE STAGE GAS FURNACE FORM NO. 92G1-100 (10/2018) CONFIGURATIONS Upflow/Horizontal Downflow HEAT EXCHANGER DESIGN Aluminized steel design primary heat exchanger with crimped

More information

Rheem Classic Plus Series Downflow Gas Furnace

Rheem Classic Plus Series Downflow Gas Furnace Gas Furnaces Rheem Classic Plus Series Downflow Gas Furnace R801T Downflow Series 80% A.F.U.E. Input Rates 75-125 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department

More information

GMS8/GDS8/GHS8. Single-Stage, Multi-Speed, Multi-Position Gas Furnace 80% AFUE. Heating Input : 40, ,000 BTU/h

GMS8/GDS8/GHS8. Single-Stage, Multi-Speed, Multi-Position Gas Furnace 80% AFUE. Heating Input : 40, ,000 BTU/h // Heating Input : 40,000 140,000 BTU/h Single-Stage, Multi-Speed, Multi-Position Gas Furnace 80% AFUE Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 5 Airflow Data... 8 Wiring Diagrams...

More information

GMSS92 / GCSS92 Single-Stage Multi-Speed Gas Furnace

GMSS92 / GCSS92 Single-Stage Multi-Speed Gas Furnace Heating Input: 40,000 120,000 BTU/h / Single-Stage Multi-Speed Gas Furnace up to 92% AFUE Standard Features Heavy-duty aluminized-steel tubular heat exchanger Stainless-steel secondary heat exchanger Single-stage

More information

FG7T (A and K Series)

FG7T (A and K Series) TECHNICAL SPECIFICATIONS FG7T (A and K Series), Smartlite Two Stage, Variable Speed, High Efficiency Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 80 + AFUE Input 60,000-140,000 Btuh The

More information