80 TDD2B060,080, C100,D120A9V

Size: px
Start display at page:

Download "80 TDD2B060,080, C100,D120A9V"

Transcription

1 Downflow/Horizontal Right or Downflow/Horizontal Left 2-Stage, Variable Speed Gas-Fired Furnace XV 80 TDD2B060,080, C100,D120A9V Two-Stage Fan Assisted Combustion System TDD-D-1 PUB. NO

2 General Features NATURAL GAS MODELS Central Heating furnace designs are certified by the American Gas Association for both natural and L.P. gas. Limit setting and rating data were established and approved under standard rating conditions using American National Standards Institute standards. SAFE OPERATION The Integrated System Control has solid state devices, which continuously monitor for presence of flame, when the system is in the heating mode of operation. Dual solenoid combination gas valve and regulator provide extra safety. QUICK HEATING Durable, cycle tested, heavy gauge aluminized steel heat exchanger quickly transfers heat to provide warm conditioned air to the structure. BURNERS Multiport Inshot burners will give years of quiet and efficient service. All models can be converted to L.P. gas. INTEGRATED SYSTEM CONTROL Exclusively designed operational program provides total control of furnace limit sensors, blowers, gas valve, flame control and includes self diagnostics for ease of service. Also contains connection points for E.A.C./humidifier. AIR DELIVERY The variable speed, direct drive blower motor, has sufficient airflow for most heating and cooling requirements, will switch from heating to cooling speeds on demand from room thermostat. The blower door safety switch will prevent or terminate furnace operation when the blower door is removed. STYLING Heavy gauge steel and wrap-around cabinet construction is used in the cabinet with baked-on enamel finish for strength and beauty. The heat exchanger section of the cabinet is completely lined with foil faced fiberglass insulation. This results in quiet and efficient operation due to the excellent acoustical and insulating qualities of fiberglass. FEATURES AND GENERAL OPERATION The XV 80 High Efficiency Gas Furnaces employs an adaptive Hot Surface Ignition system, which eliminates the waste of a constant burning pilot. The integrated system control lights the main burners upon a demand for heat from the room thermostat. Complete front service access. a. Low energy power venter b. Vent proving pressure switch Trane 2 Pub. No

3 Contents Feature Summary Features and Benefits Standard Equipment Optional Equipment General Data TDD2B060A9V3VA TDD2B080A9V3VA TDD2C100A9V5VA TDD2D120A9V5VA Performance Data Electrical Data Field Wiring Dimensions Pub. No

4 Features and Benefits XV 80 DOWNF/HORIZONTAL RIGHT or LEFT STANDARD EQUIPMENT Convertible to horizontal Power supply 2-stage gas valve 2-speed venter Hot surface igniter Integrated system control Attractive color accents Heavy gauge aluminized steel heat exchanger Soft start - gradually cycles on airflow Direct drive variable speed motor Blower door safety switch Multiport Inshot burners Complete front service access Molded plastic nameplate Comfort-R ΤΜ Slide out blower assembly Adjustable fan off times Common vent capability Cleanable high velocity filters Heavy gauge reinforced wrap-around steel cabinet Super quiet performance Optional L.P. conversion kit Left/right gas connection 4 Pub. No

5 Features and Benefits XV 80 OPTIONAL EQUIPMENT Thermostat, Mechanical 2-Stage Heating/1-Stage Cooling... TAYSTAT241 [ ] Thermostat, Heating/Cooling Single Stage (Mounts Horizontally)... AY28X092 [ ] Thermostat, Heating/Cooling Single Stage (Mounts Vertically)... BAYSTAT305 [ ] Thermostat, Electronic Programmable 2-Stage Heating/2-Stage Cooling... TAYSTAT302C [ ] Thermostat, Electronic Programmable 1-Stage Heating/1-Stage Cooling... TAYSTAT300C [ ] Thermostat, Electronic 1Htg/1Clg (Non-Prog)... TAYSTAT370 [ ] Thermostat, Electronci 1Htg/1Clg (Prog-5/2)... TAYSTAT340 [ ] Propane Conversion Kit... BAYLPKT210A [ ] Electronic Air Filter, Perfect Fit High Efficiency (17-1/2" Wide Gas Furnace)... TFM175A9FR0 [ ] Electronic Air Filter, Perfect Fit High Efficiency (21" Wide Gas Furnace)... TFM210A9FR0 [ ] Electronic Air Filter, Perfect Fit High Efficiency (24-1/2" Wide Gas Furnace)... TFM245A9FR0 [ ] Electronic Air Filter, Perfect Fit Standard Efficiency (17-1/2" Wide Gas Furnace)... TFP175A9FR0 [ ] Electronic Air Filter, Perfect Fit Standard Efficiency (21" Wide Gas Furnace)... TFP210A9FR0 [ ] Electronic Air Filter, Perfect Fit Standard Efficiency (24-1/2" Wide Gas Furnace)... TFP245A9FR0 [ ] Coil Enclosure (17-1/2" Wide Cabinets)... BAYCLE17A1722A [ ] Coil Enclosure (21" Wide Cabinets)... BAYCLE21A2130A [ ] Coil Enclosure (24-1/2" Wide Cabinets)... BAYCLE24A2430A [ ] Subbase... BAYBASE205 [ ] Filter Access Door Kit... BAYFLTR206 [ ] High Altitude Switch... BAYHALT249 [ ] Masonary Chimney Vent Kit... BAYVENT800B [ ] Pub. No

6 General Data MODEL TYPE RATINGS 2 1st Stage Input BTUH 1st Stage Capacity BTUH (ICS) 3 2nd Stage Input BTUH 2nd Stage Capacity BTUH (ICS) 3 AFUE (ICS) Temp. rise (Min.-Max.) F. BER DRIVE Diameter - Width (In.) No. Used Speeds (No.) vs. in. w.g. Motor HP R.P.M. Volts / Ph / Hz COMBUSTION FAN - Type Drive - No. Speeds Motor HP - RPM Volts / Ph / Hz FLA FILTER Furnished? Type Recommended Hi Vel. (No.-Size-Thk.) VENT Size (in.) HEAT EXCHANGER Type -Fired -Unfired Gauge (Fired) ORIFICES Main Nat. Gas. Qty. Drill Size L.P. Gas Qty. Drill Size GAS VALVE PILOT SAFETY DEVICE Type BURNERS Type Number POWER CONN. V / Ph / Hz 4 Ampacity (In Amps) Max. Overcurrent Protection (Amps) PIPE CONN. SIZE (IN.) DIMENSIONS Crated (In.) WEIGHT Shipping (Lbs.) / Net (Lbs) PRODUCT SPECIFICATIONS 1 TDD2B060A9V3VA Downflow / Horizontal 39,000 31,200 60,000 48, Direct 10 x 7 1 Variable See Airflow Table 1/2 Variable Centrifugal Direct - 2 1/ Yes High Velocity 2-14 x 20-1 in. 4 Round Alum. Steel - Type Redundant - Two Stage Hot Surface Ignition Multiport Inshot /2 H x W x D 41-3/4 x 19-1/2 x 30-1/2 140 / 129 TDD2B080A9V3VA Downflow / Horizontal 52,000 41,600 80,000 63, Direct 10 x 7 1 Variable See Airflow Table 1/2 Variable Centrifugal Direct - 2 1/ Yes High Velocity 2-14 x 20-1 in. 4 Round Alum. Steel - Type Redundant - Two Stage Hot Surface Ignition Multiport Inshot /2 H x W x D 41-3/4 x 19-1/2 x 30-1/2 146 / Central Furnace heating designs are certified by AGA and CSA. 2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian applicaitons, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level. 3 Based on U.S. government standard tests. 4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes. 6 Pub. No

7 General Data MODEL TYPE RATINGS 2 1st Stage Input BTUH 1st Stage Capacity BTUH (ICS) 3 2nd Stage Input BTUH 2nd Stage Capacity BTUH (ICS) 3 AFUE (ICS) Temp. rise (Min.-Max.) F. BER DRIVE Diameter - Width (In.) No. Used Speeds (No.) vs. in. w.g. Motor HP R.P.M. Volts / Ph / Hz COMBUSTION FAN - Type Drive - No. Speeds Motor HP - RPM Volts / Ph / Hz FLA FILTER Furnished? Type Recommended Hi Vel. (No.-Size-Thk.) VENT Size (in.) HEAT EXCHANGER Type -Fired -Unfired Gauge (Fired) ORIFICES Main Nat. Gas. Qty. Drill Size L.P. Gas Qty. Drill Size GAS VALVE PILOT SAFETY DEVICE Type BURNERS Type Number POWER CONN. V / Ph / Hz 4 Ampacity (In Amps) Max. Overcurrent Protection (Amps) PIPE CONN. SIZE (IN.) DIMENSIONS Crated (In.) WEIGHT Shipping (Lbs.) / Net (Lbs) PRODUCT SPECIFICATIONS 1 TDD2C100A9V5VA Downflow / Horizontal 65,000 52, ,000 81, Direct 11 x 10 1 Variable See Airflow Table 1 Variable Centrifugal Direct - 2 1/ Yes High Velocity 2-16 x 20-1 in. 4 Round Alum. Steel Redundant - Two Stage Hot Surface Ignition Multiport Inshot /2 H x W x D 41-3/4 x 23 x 30-1/2 166 / 155 TDD2D120A9V5VA Downflow / Horizontal 78,000 62, ,000 95, Direct 11 x 10 1 Variable See Airflow Table 1 Variable Centrifugal Direct - 2 1/ Yes High Velocity 2-16 x 20-1 in. 4 Round Alum. Steel Redundant - Two Stage Hot Surface Ignition Multiport Inshot /2 H x W x D 41-3/4 x 26-1/2 x 30-1/2 197 / Central Furnace heating designs are certified by AGA and CSA. 2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian applicaitons, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level. 3 Based on U.S. government standard tests. 4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes. Pub. No

8 Performance Data *DD2B060A9V3VA FURNACE HEATING AIRF () AND POWER () VS. EXTERNAL STATIC PRESSURE WITH FILTER AIRF SETTING DIP SWITCH SETTING EXTERNAL STATIC PRESSURE SW7 SW ON ON HEATING 1ST STAGE MEDIUM ** ON OFF OFF OFF ON ON HEATING 2ND STAGE MEDIUM ** ON OFF OFF OFF OUTDOOR UNIT SIZE (TONS) *DD2B060A9V3VA FURNACE COOLING AIRF () AND POWER () VS. EXTERNAL STATIC PRESSURE WITH FILTER AIRF SETTING DIP SWITCH SETTING EXTERNAL STATIC PRESSURE SW1 SW2 SW3 SW (350 / ON ON OFF ON (400 / ON ON OFF OFF (450 / ON ON ON OFF (350 / OFF ON OFF ON (400 / OFF ON OFF OFF (450 / OFF ON ON OFF (350 / ON OFF OFF ON (400 / ON OFF OFF OFF (450 / ON OFF ON OFF (350 / OFF OFF OFF ON ** ** OFF OFF OFF OFF (400 / (450 / OFF OFF ON OFF NOTES: 1. *FIRST LETTER MAY BE "A" OR "T" 2. **FACTORY SETTING. 3. CONTINUOUS FAN SETTING: HEATING OR COOLING AIRF IS APPROXIMATELY 50% OF SELECTED COOLING VALUE. 4. FOR VARIABLE SPEED: SPEED AIRFS ARE APPROXIMATELY 30% OF LISTED VALUES /TON IS RECOMMENDED FOR VARIABLE SPEED APPLICATION FOR COMFORT & HUMID CLIMATE SETTING: IS 400 /TON: 450 /TON IS FOR DRY CLIMATE SETTING. 8 Pub. No

9 Performance Data *DD2B080A9V3VA FURNACE HEATING AIRF () AND POWER () VS. EXTERNAL STATIC PRESSURE WITH FILTER HEATING 1ST STAGE HEATING 2ND STAGE AIRF SETTING DIP SWITCH SETTING EXTERNAL STATIC PRESSURE SW 7 SW ON ON MEDIUM ** ON OFF OFF OFF ON ON MEDIUM ** ON OFF OFF OFF *DD2B080A9V3VA FURNACE COOLING AIRF () AND POWER () VS. EXTERNAL STATIC PRESSURE WITH FILTER OUTDOOR UNIT SIZE (TONS) AIRF SETTING DIP SWITCH SETTING EXTERNAL STATIC PRESSURE SW 1 SW 2 SW 3 SW (350 / OFF ON OFF ON (400 / OFF ON OFF OFF (450 / OFF ON ON OFF (350 / ON OFF OFF ON (400 / ON OFF OFF OFF (450 / ON OFF ON OFF (350 / OFF OFF OFF ON ** ** (400 / OFF OFF OFF OFF (450 / OFF OFF ON OFF NOTES: 1. * First letter may be "A" or "T" 2. ** Factory setting 3. Continuous Fan Setting: Heating or Cooling airflow is approximately 50% of selected Cooling value. 4. For Variable Speed: low speed airflows are approximately 30% of listed values cfm/ton is recommended for Variable Speed application for COMFORT & HUMID CLIMATE setting; is 400 cfm/ton; 450 cfm/ton is for DRY CLIMATE setting Pub. No

10 Performance Data *DD2C100A9V5VA FURNACE HEATING AIRF () AND POWER () VS. EXTERNAL STATIC PRESSURE WITH FILTER HEATING 1ST STAGE HEATING 2ND STAGE AIRF SETTING DIP SWITCH SETTING EXTERNAL STATIC PRESSURE SW 7 SW ON ON MEDIUM ** ON OFF OFF OFF ON ON MEDIUM ** ON OFF OFF OFF *DD2C100A9V5VA FURNACE COOLING AIRF () AND POWER () VS. EXTERNAL STATIC PRESSURE WITH FILTER OUTDOOR UNIT SIZE (TONS) AIRF SETTING DIP SWITCH SETTING EXTERNAL STATIC PRESSURE SW 1 SW 2 SW 3 SW (350 / (400 / ON ON OFF ON ON ON OFF OFF (450 / ON ON ON OFF (350 / (400 / OFF ON OFF ON OFF ON OFF OFF (450 / OFF ON ON OFF (350 / (400 / ON OFF OFF ON ON OFF OFF OFF (450 / ON OFF ON OFF ** (350 / ** (400 / OFF OFF OFF ON OFF OFF OFF OFF (450 / OFF OFF ON OFF NOTES: 1. * First letter may be "A" or "T" 2. ** Factory setting 3. Continuous Fan Setting: Heating or Cooling airflow is approximately 50% of selected Cooling value. 4. For Variable Speed: low speed airflows are approximately 30% of listed values cfm/ton is recommended for Variable Speed application for COMFORT & HUMID CLIMATE setting; is 400 cfm/ton; 450 cfm/ton is for DRY CLIMATE setting 10 Pub. No

11 Performance Data *DD2D120A9V5VA FURNACE HEATING AIRF () AND POWER () VS. EXTERNAL STATIC PRESSURE WITH FILTER AIRF SETTING DIP SWITCH SETTING EXTERNAL STATIC PRESSURE SW 7 SW ON ON HEATING 1ST STAGE MEDIUM ** ON OFF OFF OFF ON ON HEATING 2ND STAGE MEDIUM ** ON OFF OFF OFF *DD2D120A9V5VA FURNACE COOLING AIRF () AND POWER () VS. EXTERNAL STATIC PRESSURE WITH FILTER OUTDOOR UNIT SIZE (TONS) AIRF SETTING DIP SWITCH SETTING EXTERNAL STATIC PRESSURE SW 1 SW 2 SW 3 SW (350 / OFF ON OFF ON (400 / OFF ON OFF OFF (450 / OFF ON ON OFF (350 / ON OFF OFF ON (400 / ON OFF OFF OFF (450 / ON OFF ON OFF (350 / OFF OFF OFF ON ** ** (400 / OFF OFF OFF OFF (450 / OFF OFF ON OFF NOTES: 1. * First Letter may be "A" or "T" 2. ** Factory setting 3. Continuous Fan Setting: Heating or Cooling airflow is approximately 50% of selected Cooling value. 4. For Variable Speed: low speed airflows are approximately 30% of listed values cfm/ton is recommended for Variable Speed application for COMFORT & HUMID CLIMATE setting; is 400 cfm/ton; 450 cfm/ton is for DRY CLIMATE setting Pub. No

12 Electrical Data LEGEND SCHEMATIC DIAGRAMS FOR GAS FURNACES 12 Pub. No

13 Field Wiring FIELD WIRING DIAGRAM FOR SINGLE STAGE HEATING ONLY FIELD WIRING DIAGRAM FOR TWO STAGE HEATING From Dwg. 21B Rev. 0 From Dwg. 21B341 Rev. 0 Pub. No

14 Field Wiring FIELD WIRING DIAGRAM FOR SINGLE STAGE HEATING WITH SINGLE STAGE COOLING (OUTDOOR SECTION WITHOUT TRANSFORMER) FIELD WIRING DIAGRAM FOR TWO STAGE HEATING WITH SINGLE STAGE COOLING (OUTDOOR SECTION WITHOUT TRANSFORMER) From Dwg. 21B Rev. 0 From Dwg. 21B Rev Pub. No

15 Field Wiring FIELD WIRING DIAGRAM FOR TWO STAGE HEATING WITH TWO STAGE COOLING (OUTDOOR SECTION WITHOUT TRANSFORMER) From Dwg. 21B Rev. 0 Pub. No

16 Dimensions TDD-R9V OUTLINE DRAWING (ALL DIMENSIONS ARE IN INCHES) MODEL A B C D *DD060R9V3F *DD080R9V3F 17-1/2" 9-5/8" 16-1/4" 16" *DD100R9V5F 21" 13-1/16" 19-3/4" 19-1/2" *DD120R9V5F 24-1/2" 15-5/16" 23-1/4" 23" * - The First Letter May Be "A" or "T" From Dwg. 21C Sh. 1 Rev. 0 Trane 6200 Troup Highway Tyler, TX Since Trane has a policy of continuous product improvement, it reserves the right to change design and specifications without notice.

XV 80 TDD2B060,080, C100,D120A9V

XV 80 TDD2B060,080, C100,D120A9V Downflow/Horizontal Right or Left 2-Stage Variable Speed Gas-Fired Furnace XV 80 TDD2B060,080, C100,D120A9V Two-Stage Fan Assisted Combustion System PUB. NO. 22-1673-10 General Features NATURAL GAS MODELS

More information

XV80 UPFLOW/HORIZONTAL 2-STAGE, VARIABLE SPEED GAS-FIRED FURNACE

XV80 UPFLOW/HORIZONTAL 2-STAGE, VARIABLE SPEED GAS-FIRED FURNACE UPF/HORIZONTAL 2-, VARIABLE SPEED GAS-FIRED FURNACE XV80 MODELS TUD2B060A9V3VB TUD2B080A9V3VB TUD2C080A9V4VB TUD2C080B9V4VB TUD2B00A9V3VB TUD2C00A9V5VB TUD2C00B9V5VB TUD2DA9V5VB TUD2DB9V5VB TUD2DA9V5VB

More information

XC 95m. Communicating Upflow/Horizontal Left Downflow/Horizontal Right Direct/Non-Direct Vent Variable Speed, Modulating Condensing Gas Furnace

XC 95m. Communicating Upflow/Horizontal Left Downflow/Horizontal Right Direct/Non-Direct Vent Variable Speed, Modulating Condensing Gas Furnace TUHM Communicating Upflow/Horizontal Left Downflow/Horizontal Right Direct/Non-Direct Vent Variable Speed, Modulating Condensing Gas Furnace XC 95m TUHMB060ACV3VA, TDHMB060BCV3VA TUHMB080ACV3VA, TDHMB080ACV3VA

More information

XC 95m. Communicating Upflow/Horizontal Left Downflow/Horizontal Right Direct/Non-Direct Vent Variable Speed, Modulating Condensing Gas Furnace

XC 95m. Communicating Upflow/Horizontal Left Downflow/Horizontal Right Direct/Non-Direct Vent Variable Speed, Modulating Condensing Gas Furnace TUHM Communicating Upflow/Horizontal Left Downflow/Horizontal Right Direct/Non-Direct Vent Variable Speed, Modulating Condensing Gas Furnace XC 95m TUHMB060ACV3VB, TDHMB060BCV3VB TUHMB080ACV3VB, TDHMB080ACV3VB

More information

XC 95. Communicating Only Upflow/Horizontal Left Downflow/Horizontal Right Direct/Non-Direct Vent 3 Stage Gas Furnace with. Variable Speed Inducer

XC 95. Communicating Only Upflow/Horizontal Left Downflow/Horizontal Right Direct/Non-Direct Vent 3 Stage Gas Furnace with. Variable Speed Inducer TUH3-AC-V Communicating Only Upflow/Horizontal Left Downflow/Horizontal Right Direct/Non-Direct Vent 3 Stage Gas Furnace with Speed Inducer XC 95 TUH3B060ACV3VA, TDH3B060ACV3VA TUH3B080ACV3VA, TDH3B080ACV3VA

More information

Upflow/ Horizontal Left, Downflow/ Horizontal Right Variable Speed Two Stage Condensing Gas-Fired Furnace Freedom 95

Upflow/ Horizontal Left, Downflow/ Horizontal Right Variable Speed Two Stage Condensing Gas-Fired Furnace Freedom 95 *UHA9VV Upflow/ Horizontal Left, Downflow/ Horizontal Right Speed Two Stage Condensing GasFired Furnace Freedom 95 AUH2B060A9V3VA, ADH2B060A9V3VA AUH2B080A9V3VA, ADH2B080A9V3VA AUH2C100A9V4VA, ADH2C100A9V4VA

More information

Upflow/ Horizontal Left/Right, Downflow Two Stage Condensing Gas Fired Furnace

Upflow/ Horizontal Left/Right, Downflow Two Stage Condensing Gas Fired Furnace Product Data Upflow/ Horizontal Left/Right, Downflow Two Condensing Gas Fired Furnace Upflow, Convertible to HorizontalRight or HorizontalLeft S9V2B040U3PSBB S9V2B060U3PSBB S9V2B060U4PSBB S9V2B080U3PSBB

More information

XP80 / XV80 Highboy Vertical THV1M087A936,V3,SA THV1M087A948,V5,SA

XP80 / XV80 Highboy Vertical THV1M087A936,V3,SA THV1M087A948,V5,SA TDD-D-1 Vertical boy, boy Front Flue, boy Rear Flue, Downflow/Horizontal Oil-Fired Furnace XP80 / XV80 boy Vertical THV1M087A936,V3,SA THV1M087A948,V5,SA Downflow/Horizontal Front Flue TDF1M087A936,V3,SA

More information

GMS9/GCS9 SERIES 93% AFUE

GMS9/GCS9 SERIES 93% AFUE / SERIES 93% AFUE MULTI-POSITION, SINGLE-STAGE/MULTI-SPEED GAS FURNACE HEATING CAPACITY: 46,000 115,000 BTU/H Standard Features Corrosion-resistant, aluminized-steel tubular heat exchanger and stainless-steel

More information

PRODUCT SPECIFICATIONS GMS8/GDS8/GHS8 SERIES 80% AFUE MULTI-POSITION, SINGLE-STAGE/MULTI-SPEED GAS FURNACE

PRODUCT SPECIFICATIONS GMS8/GDS8/GHS8 SERIES 80% AFUE MULTI-POSITION, SINGLE-STAGE/MULTI-SPEED GAS FURNACE GMS8/GDS8/GHS8 SERIES 80% AFUE MULTI-POSITION, SINGLE-STAGE/MULTI-SPEED GAS FURNACE HEATING CAPACITY: 45,000 1,000 BTUH The GMS8/GDS8/GHS8 single-stage, multi-speed gas furnaces offer installation versatility.

More information

Ruud Ultra Series Communicating Two-Stage Variable Speed Downflow Gas Furnace

Ruud Ultra Series Communicating Two-Stage Variable Speed Downflow Gas Furnace Gas Furnaces Ruud Ultra Series Communicating Two-Stage Variable Speed Downflow Gas Furnace U802V Downflow Series 80% A.F.U.E. Input Rates 75-125 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated

More information

Modular Variable Speed Air Handlers

Modular Variable Speed Air Handlers Modular Variable Speed Air Handlers Convertible Variable Speed Communicating Air Handlers - 1 1/2-5 Ton 4TEE3C01A1000A 4TEE3C02A1000A 4TEE3C03A1000A 4TEE3C04A1000A 4TEE3C05A1000A 4TEE3C06A1000A 4TEE3C07A1000A

More information

W801S (Downflow) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. )

W801S (Downflow) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. ) FORM NO. G66-547 REV. 4 Supersedes Form No. G66-536 Rev. 3 DOWNF GAS FURNACE Features 80% residential Gas Furnace CSA certified 7 Segment LED all units Direct spark ignition for reliability and longevity

More information

Product Data. S Variable-speed ECM blower motor. S Two heating stages. S Humidity control when using a humidity sensing thermostat

Product Data. S Variable-speed ECM blower motor. S Two heating stages. S Humidity control when using a humidity sensing thermostat PG8MVA PG8JVA 4 --- WAY MULTIPOISE INDUCED---COMBUSTION GAS FURNACE INPUT CAPACITIES: 70,000 thru 135,000 Btuh SERIES A Product Data multipoise design, through -the-furnace downflow venting, 13 different

More information

Multi-Position, Multi-Speed Gas Furnaces

Multi-Position, Multi-Speed Gas Furnaces Heating Input: 40,000 140,000 BTU/h / Multi-Position, Multi-Speed Gas Furnaces 80% AFUE Standard Features Dual-diameter tubular heat exchanger Two-stage gas valve control technology allows installer to

More information

W801T (Downflow) Series Models with Input Rates from 75 to 125 kbtu [15 to 37 kw] (80% A.F.U.E. )

W801T (Downflow) Series Models with Input Rates from 75 to 125 kbtu [15 to 37 kw] (80% A.F.U.E. ) FORM NO. G66-549 REV. 3 Supersedes Form No. G66-536 Rev. 3 DOWNFLOW GAS FURNACE Features 80% residential Gas Furnace CSA certified 7 Segment LED all units Direct Spark Ignition System for reliability and

More information

95G2E PRODUCT SPECIFICATIONS 95% TWO-STAGE CONSTANT TORQUE GAS FURNACES CONTROLS VENTING CONFIGURATIONS HEAT EXCHANGER DESIGN INSTALLATION FEATURES

95G2E PRODUCT SPECIFICATIONS 95% TWO-STAGE CONSTANT TORQUE GAS FURNACES CONTROLS VENTING CONFIGURATIONS HEAT EXCHANGER DESIGN INSTALLATION FEATURES 95G2E PRODUCT SPECIFICATIONS 95% TWO-STAGE CONSTANT TORQUE GAS FURNACES FORM NO. 95G2E-100 (04/2016) CONTROLS Two stage gas valve Integrated ignition and fan control Control board retains last ten (10)

More information

DUAL COMFORT CONTROL TWO-STAGE DOWNFLOW/HORIZONTAL GAS FURNACES WITH

DUAL COMFORT CONTROL TWO-STAGE DOWNFLOW/HORIZONTAL GAS FURNACES WITH FORM NO. GSC-531 REV. 1 Supersedes Form No. GSC-488 Rev. 7 GF902D SERIES Models with Input Rates from 60 to 120 kbtu [17.58 to 35.17 kw] (All Models 92% A.F.U.E. or Above) TWO-STAGE DOWNFLOW/HORIZONTAL

More information

OIL FIRED UPFLOW FURNACE SPECIFICATIONS THV1C072A948SA (BECKETT AFG)

OIL FIRED UPFLOW FURNACE SPECIFICATIONS THV1C072A948SA (BECKETT AFG) MODEL NO. THV1C072A948SA (BECKETT AFG) THV1C072A9V4SA (BECKETT AFG) HEATING CAPACITY High Fire Med Fire Low Fire High Fire Med Fire Low Fire HEAT INPUT RATE (BTUH) 106,250 85,000 70,000 106,250 85,000

More information

Rheem Classic Series Downflow Gas Furnace

Rheem Classic Series Downflow Gas Furnace Gas Furnaces Rheem Classic Series Downflow Gas Furnace R801S (Downflow) Series 80% A.F.U.E. Input Rates 50-150 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department

More information

GF802D SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (U.S. & Canadian Models)

GF802D SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (U.S. & Canadian Models) FORM NO. GSC-515 GF802D SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (U.S. & Canadian Models) TWO STAGE DOWNFLOW GAS FURNACES The Sure Comfort 2-Stage line of downflow gas furnaces

More information

GMH95/GCH9 PRODUCT SPECIFICATIONS 95%/93% AFUE HEAT REPLACEMENT MULTI-POSITION, TWO-STAGE (CONVERTIBLE), MULTI-SPEED GAS FURNACE

GMH95/GCH9 PRODUCT SPECIFICATIONS 95%/93% AFUE HEAT REPLACEMENT MULTI-POSITION, TWO-STAGE (CONVERTIBLE), MULTI-SPEED GAS FURNACE / 95%/93% AFUE MULTI-POSITION, TWO-STAGE (CONVERTIBLE), MULTI-SPEED GAS FURNACE HEATING INPUT: 46,000 115,000 BTU/H LIFETIME HEAT EXCHANGER LIMITED WARRANTY 10 YEAR HEAT REPLACEMENT CXCHANGER WARRANTY

More information

Rheem Classic Plus Series Downflow Gas Furnace

Rheem Classic Plus Series Downflow Gas Furnace Gas Furnaces Rheem Classic Plus Series Downflow Gas Furnace R801T Downflow Series 80% A.F.U.E. Input Rates 75-125 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department

More information

G23 Bulletin # September 1998 Supersedes June 1995

G23 Bulletin # September 1998 Supersedes June 1995 ENGINEERING DATA ELITE 80Z UP-FLOW GAS FURNACES *80.0% to 80.8% A.F.U.E. 50,000 to 150,000 Btuh (14.7 to 44.0 kw) Gas Heating Input 1 thru 6 Tons (3.5 thru 21.1 kw) Nominal Add-On Cooling *Isolated Combustion

More information

TECHNICAL GUIDE 80 AFUE DOWNFLOW GAS-FIRED FURNACES MODELS: G8T-DN DESCRIPTION WARRANTY FEATURES Rev. B (0303)

TECHNICAL GUIDE 80 AFUE DOWNFLOW GAS-FIRED FURNACES MODELS: G8T-DN DESCRIPTION WARRANTY FEATURES Rev. B (0303) TECHNICAL GUIDE 80 AFUE DOWNFLOW GAS-FIRED FURNACES MODELS: G8T-DN 40-130 MBH INPUT HIGH-EFFICIENCY INDUCED COMBUSTION DESCRIPTION These high efficiency, dedicated downflow compact units employ induced

More information

UPFLOW/ HORIZONTAL GAS FURNACE

UPFLOW/ HORIZONTAL GAS FURNACE FORM NO. GFJ-542 UPFLOW/ HORIZONTAL GAS FURNACE Features 80% residential Gas Furnace CSA certified 3 way multi poise design UF / HZ 7 Segment LED all units Direct Spark Ignition for reliability and longevity

More information

W801S (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. )

W801S (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. ) FORM NO. G66-542 REV. 4 Supersedes Form No. G66-536 Rev. 3 W801S (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. ) UPFLOW/ HORIZONTAL GAS FURNACES Features

More information

Rheem Prestige Series Communicating Two-Stage Variable Speed Upflow/Horizontal Gas Furnace

Rheem Prestige Series Communicating Two-Stage Variable Speed Upflow/Horizontal Gas Furnace Gas Furnaces Rheem Prestige Series Communicating Two-Stage Variable Speed Upflow/Horizontal Gas Furnace R802V- Upflow/Horizontal Series 80% A.F.U.E. Input Rates 50-125 kbtu A.F.U.E. (Annual Fuel Utilization

More information

A962E PRODUCT SPECIFICATIONS TWO STAGE HIGH EFFICIENCY CONSTANT TORQUE GAS FURNACE CONTROLS VENTING CONFIGURATIONS HEAT EXCHANGER DESIGN

A962E PRODUCT SPECIFICATIONS TWO STAGE HIGH EFFICIENCY CONSTANT TORQUE GAS FURNACE CONTROLS VENTING CONFIGURATIONS HEAT EXCHANGER DESIGN A962E PRODUCT SPECIFICATIONS TWO STAGE HIGH EFFICIENCY CONSTANT TORQUE GAS FURNACE FORM NO. A962E-100 (04/2018) CONTROLS Two stage gas valve Integrated ignition and fan control System Sentry control retains

More information

FORM NO. GTZ-542 Supersedes Form No. GTZ-503 Rev. 1

FORM NO. GTZ-542 Supersedes Form No. GTZ-503 Rev. 1 FORM NO. GTZ-542 Supersedes Form No. GTZ-503 Rev. 1 TZ80MSS (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] UPFLOW/ HORIZONTAL GAS FURNACES Features 80% residential

More information

TECHNICAL GUIDE MODELS: P4DN 80 AFUE DOWNFLOW GAS-FIRED FURNACES DESCRIPTION. WARRANTY 20-year limited warranty on the heat exchanger.

TECHNICAL GUIDE MODELS: P4DN 80 AFUE DOWNFLOW GAS-FIRED FURNACES DESCRIPTION. WARRANTY 20-year limited warranty on the heat exchanger. 036-21053-001 Rev. A (4/00) DESCRIPTION These high efficiency, dedicated downflow compact units employ induced combustion, reliable hot surface ignition and high heat transfer tubular heat exchangers.

More information

A95-2V. 95% Gas Furnaces Two-Stage Variable Speed HEAT EXCHANGER DESIGN CONFIGURATIONS

A95-2V. 95% Gas Furnaces Two-Stage Variable Speed HEAT EXCHANGER DESIGN CONFIGURATIONS Two- Variable Speed HEAT EXCHANGER DESIGN 409 Stainless steel primary heat exchanger material AL29-4C Stainless steel secondary heat exchanger Non-welded crimped S-curve primary heat exchanger design for

More information

GAS FURNACES CLASSIC SERIES SUPER QUIET 80 80% A.F.U.E. DOWNFLOW GAS FURNACES

GAS FURNACES CLASSIC SERIES SUPER QUIET 80 80% A.F.U.E. DOWNFLOW GAS FURNACES FORM NO. G11-487 REV. 1 Supersedes Form No. G11-487 Rev. 8 GAS FURNACES RGLN- SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] (U.S. & Canadian Models) Annual Fuel Utilization

More information

TZ80MSX (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu [15 to 37 kw] FORM NO. GTZ-544 Supersedes Form No. GTZ-503 Rev.

TZ80MSX (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu [15 to 37 kw] FORM NO. GTZ-544 Supersedes Form No. GTZ-503 Rev. FORM NO. GTZ-544 Supersedes Form No. GTZ-503 Rev. 1 UPFLOW/ HORIZONTAL GAS FURNACES Features 80% residential Gas Furnace CSA certified 3 way multi poise design UF / HZ 7 Segment LED all units Direct Spark

More information

KG7T (E and N Series)

KG7T (E and N Series) TECHNICAL SPECIFICATIONS KG7T (E and N Series) Two Stage, Fixed Speed ECM, Condensing Upflow and Downflow Gas Furnaces Induced Draft - 96% AFUE Input 60,000-115,000 Btuh The high efficiency upflow gas

More information

FG7T (E and N Series)

FG7T (E and N Series) TECHNICAL SPECIFICATIONS FG7T (E and N Series), Smartlite Two Stage, Fixed Speed ECM, High Efficiency Upflow and Downflow Gas Furnaces Induced Draft - 96% AFUE Input 60,000-115,000 Btuh The high efficiency

More information

DD80HS. Two-Stage, Convertible Multi-Speed Gas Furnace 80% AFUE. Heating Input: 40, ,000 BTU/h

DD80HS. Two-Stage, Convertible Multi-Speed Gas Furnace 80% AFUE. Heating Input: 40, ,000 BTU/h Two-Stage, Convertible Multi-Speed Gas Furnace 80% AFUE Heating Input: 40,000 100,000 BTU/h Contents Nomenclature...2 Product Specifications...3 Dimensions...4 Airflow Data...5 Wiring Diagram...7 Accessories...8

More information

OIL FIRED LOWBOY FURNACE SPECIFICATIONS

OIL FIRED LOWBOY FURNACE SPECIFICATIONS OIL FIRED BOY FURNACE SPECIFICATIS MODEL NO. HEATING CAPACITY TLF1M087C942SA TLR1M087C942SA High Fire Med-High Fire (BECKETT AFG) Med-Low Fire [5] Low Fire High Fire Med-High Fire TLF1M087D9V5SA [6] TLR1M087D9V5SA

More information

W801T (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu (80% A.F.U.E. )

W801T (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu (80% A.F.U.E. ) FORM NO. G66-544 REV. 4 Supersedes Form No. G66-536 Rev. 3 W801T (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu (80% A.F.U.E. ) UPFLOW/ HORIZONTAL GAS FURNACES Features 80% residential

More information

DM80SS / DD80SS. Single-Stage, Multi-Speed Gas Furnaces 80% AFUE Heating Input: 40, ,000 BTU/h

DM80SS / DD80SS. Single-Stage, Multi-Speed Gas Furnaces 80% AFUE Heating Input: 40, ,000 BTU/h / Single-Stage, Multi-Speed Gas Furnaces 80% AFUE Heating Input: 40,000 140,000 BTU/h Contents Nomenclature...2 Product Specifications...3 Dimensions...5 Airflow Data...8 Wiring Diagram...10 Accessories...11

More information

Ruud Achiever Plus Series Upflow/Horizontal Gas Furnace

Ruud Achiever Plus Series Upflow/Horizontal Gas Furnace Gas Furnaces Ruud Achiever Plus Series Upflow/Horizontal Gas Furnace R802P- Upflow/Horizontal Series 80% A.F.U.E. Input Rates 50-150 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance

More information

Rheem Classic Series Upflow/Horizontal Gas Furnace

Rheem Classic Series Upflow/Horizontal Gas Furnace Gas Furnaces Rheem Classic Series Upflow/Horizontal Gas Furnace R801P- Upflow/Horizontal Series 80% A.F.U.E. Input Rates 50-150 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance

More information

80% A.F.U.E. DOWNFLOW GAS FURNACES

80% A.F.U.E. DOWNFLOW GAS FURNACES FORM NO. G66-496 REV. 5 Supersedes Form No. G66-496 Rev. 4 RGLS- SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] (U.S. & Canadian Models) 80% A.F.U.E. DOWNF GAS FURNACES The

More information

Up to 96% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL

Up to 96% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL N9MSE Product Specifications Up to 96% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL Up to 96% AFUE in upflow and horizontal positions, Up to 96% AFUE in downflow positions California NOx approved

More information

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa) N8MXL Product Specifications 80% ECM Single Stage Heating Furnace EASIER TO SELL 80% AFUE Flame roll out sensors standard Category I venting Blocked vent switch 24 VAC humidifier terminal Electronic air

More information

Rheem Classic Series Two-Stage Downflow/Horizontal Gas Furnace

Rheem Classic Series Two-Stage Downflow/Horizontal Gas Furnace Gas Furnaces Rheem Classic Series Two-Stage Downflow/Horizontal Gas Furnace RGTK- Series 92% A.F.U.E. or Above 60-120 kbtu with Dual Comfort Control A.F.U.E. (Annual Fuel Utilization Efficiency) calculated

More information

80% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES

80% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES FORM NO. G66-495 Supersedes Form No. P66-765 Rev. 3 80PS- SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] 80% A.F.U.E. UPF/ HORIZONTAL GAS FURNACES The WeatherKing line of upflow/horizontal

More information

TECHNICAL GUIDE. Echelon MODELS: FC8S GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE DESCRIPTION WARRANTY FEATURES

TECHNICAL GUIDE. Echelon MODELS: FC8S GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE DESCRIPTION WARRANTY FEATURES TECHNICAL GUIDE Echelon MODELS: FC8S GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE NATURAL GAS 40-130 MBH INPUT EFFICIENCY RATING CERTIFIED DESCRIPTION These high efficiency, dedicated

More information

G8MVL. Product Specifications

G8MVL. Product Specifications 80% Variable Speed, Two Stage Heating Furnace EASIER TO SELL 80% AFUE Supports two stage cooling units Flame roll out sensors standard Category I venting Blocked vent switch Dehumidification feature in

More information

TECHNICAL GUIDE AFFINITY MODELS: PS8 GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE DESCRIPTION WARRANTY FEATURES

TECHNICAL GUIDE AFFINITY MODELS: PS8 GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE DESCRIPTION WARRANTY FEATURES TECHNICAL GUIDE AFFINITY MODELS: PS8 GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE NATURAL GAS 40-130 MBH INPUT EFFICIENCY RATING CERTIFIED DESCRIPTION These high efficiency, dedicated

More information

GUH 95 Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

GUH 95 Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS TECHNICAL SPECIFICATIONS GUH 95 Series Two Stage, Variable Speed, Condensing Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 95.1 AFUE Input 60,000-120,000 Btuh The high efficiency upflow gas

More information

Product Data. Convertible Air Handlers 1 1/2 5 Ton B-EN. August 2015

Product Data. Convertible Air Handlers 1 1/2 5 Ton B-EN. August 2015 Product Data Convertible Air Handlers 1 1/2 5 Ton TEM6A0B24H21S TEM6A0B30H21S TEM6A0C36H31S TEM6A0C42H41S TEM6A0D48H41S TEM6A0D60H51S The TEM6 series air handler is designed for installation in a closet,

More information

Rheem Classic Series Upflow/Horizontal Gas Furnace

Rheem Classic Series Upflow/Horizontal Gas Furnace THIS MODEL Air Gas Furnaces Rheem Classic Series Upflow/Horizontal Gas Furnace R801S- (Upflow/Horizontal) Series 80% A.F.U.E. Input Rates 50-150 kbtu ENER UIDE Annual Fuel Utilization Efficiency - AFUE

More information

WFEL. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design

WFEL. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design 80% AFUE GAS FURNACE Multipoise Design WFEL Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification for individual products, go to www.ahridirectory.org.

More information

N9MSB. PS 92 Product Specifications. 92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL /2/17

N9MSB. PS 92 Product Specifications. 92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL /2/17 92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 92.1% AFUE all models in all positions California NOx approved Certified to leak 2% or less of nominal air conditioning CFM delivered when pressurized

More information

Rheem Value Series Downflow Gas Furnace

Rheem Value Series Downflow Gas Furnace THIS MODEL 80.0% 78% 82% 88% 97% Air Gas Furnaces Rheem Value Series Downflow Gas Furnace RGLS- Series 80% A.F.U.E. Input Rates 50-150 kbtu ENER UIDE Annual Fuel Utilization Efficiency - AFUE MID A.F.U.E.

More information

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa) 92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 92.1% AFUE, all models all positions, California NOx approved Certified to leak 2% or less of nominal air conditioning CFM delivered when pressurized

More information

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa) 95.5% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 95.5% AFUE, all models all positions, California NOx approved Certified to leak 2% or less of nominal air conditioning CFM delivered when pressurized

More information

WFEL. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design

WFEL. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design 80% AFUE GAS FURNACE Multipoise Design WFEL Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification for individual products, go to www.ahridirectory.org.

More information

Table of Contents GF801U Series

Table of Contents GF801U Series FORM NO. GSC-520 GF801U SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] 80% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES The Sure Comfort line of upflow/horizontal gas furnaces are designed

More information

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama 58HDX COMFORT 95 DIRECT OR NON---DIRECT VENT CONDENSING GAS FURNACE

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama 58HDX COMFORT 95 DIRECT OR NON---DIRECT VENT CONDENSING GAS FURNACE COMFORT 95 DIRECT OR NON---DIRECT VENT 4 --- WAY MULTIPOISE CONDENSING GAS FURNACE 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal FLEXIBILITY S Dual certified venting (1 or 2 pipes) Direct

More information

VMS8/VDS8. Single-Stage, Single Speed, Multi-Position Gas Furnace 80% AFUE. Heating Input : 40, ,000 BTU/h

VMS8/VDS8. Single-Stage, Single Speed, Multi-Position Gas Furnace 80% AFUE. Heating Input : 40, ,000 BTU/h / Heating Input : 40,000 100,000 BTU/h Single-Stage, Single Speed, Multi-Position Gas Furnace 80% AFUE Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 5 Airflow Data... 8 Wiring Diagrams...

More information

Rheem Classic Plus Series Upflow/Horizontal Gas Furnace

Rheem Classic Plus Series Upflow/Horizontal Gas Furnace Gas Furnaces Rheem Classic Plus Series Upflow/Horizontal Gas Furnace R801T- Upflow/Horizontal Series 80% A.F.U.E. Input Rates 50-125 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance

More information

Product Data. Single Packaged Gas/Electric 15 SEER Convertible, 2 5 Ton A-EN. July 2016

Product Data. Single Packaged Gas/Electric 15 SEER Convertible, 2 5 Ton A-EN. July 2016 Product Data Single Packaged Gas/Electric 15 SEER Convertible, 2 5 Ton 4YCY5024A1060A 4YCY5030A1070A 4YCY5036A1070A 4YCY5036A1090A 4YCY5042A1090A 4YCY5048A1090A 4YCY5048A1115A 4YCY5060A1115A Note: Graphics

More information

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa) 95.5% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 95.5% AFUE, all models all positions, California NOx approved Certified to leak 2% or less of nominal air conditioning CFM delivered when pressurized

More information

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa) 92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 92.1% AFUE, all models all positions, California NOx approved Certified to leak 2% or less of nominal air conditioning CFM delivered when pressurized

More information

Product Data. that this product meets the S 95% AFUE S Two -stage operation

Product Data. that this product meets the S 95% AFUE S Two -stage operation DIRECT VENT 4 -WAY MULTIPOISE CONDENSING GAS FURNACE 95% DOWNFLOW / HORIZONTAL ORIENTATIONS 93.5% UPFLOW ORIENTATION 95% Variable Speed Two -Stage Heating Furnace FLEXIBILITY S Supports two -stage cooling

More information

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa) 92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 92.1% AFUE, all models all positions, California NOx approved Certified to leak 2% or less of nominal air conditioning CFM delivered when pressurized

More information

GMS8/GDS8/GHS8. Single-Stage, Multi-Speed, Multi-Position Gas Furnace 80% AFUE. Heating Input : 40, ,000 BTU/h

GMS8/GDS8/GHS8. Single-Stage, Multi-Speed, Multi-Position Gas Furnace 80% AFUE. Heating Input : 40, ,000 BTU/h // Heating Input : 40,000 140,000 BTU/h Single-Stage, Multi-Speed, Multi-Position Gas Furnace 80% AFUE Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 5 Airflow Data... 8 Wiring Diagrams...

More information

Operating Net Capacity BTU/h. Input BTU/h Efficiency. lbs (kg) PGR524040KGP* 23, ,000/26, /8 x 47 x 31-7/16

Operating Net Capacity BTU/h. Input BTU/h Efficiency. lbs (kg) PGR524040KGP* 23, ,000/26, /8 x 47 x 31-7/16 SOUND REFRIGERANT ENVIRONMENTALLY Product Specifications UP to 16 SEER, UP to 12.5 EER, PACKAGE GAS / ELECTRIC, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz 208/230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT

More information

Product Data /4YCC3018A through 2/4YCC3060A Single Package Convertible Gas/Electric 13 SEER 1½ - 5 Ton, MBTU R-22/R-410A

Product Data /4YCC3018A through 2/4YCC3060A Single Package Convertible Gas/Electric 13 SEER 1½ - 5 Ton, MBTU R-22/R-410A Product Data 22-1784-01 2/4YCC3018A through 2/4YCC3060A Single Package Convertible Gas/Electric 13 SEER 1½ - 5 Ton, 40-120 MBTU R-22/R-410A Mar. 03, 2006 2006 American Standard inc. All Rights Reserved

More information

GAS FURNACES CLASSIC SERIES SUPER QUIET % A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES

GAS FURNACES CLASSIC SERIES SUPER QUIET % A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES FORM NO. G11-485 REV. 5 Supersedes Form No. G11-485 Rev. 4 GAS FURNACES RGPN- SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] (U.S. & Canadian Models) ISO 9001:2000 Annual Fuel

More information

80 PLUS A.F.U.E. UPFLOW/HORIZONTAL GAS FURNACES

80 PLUS A.F.U.E. UPFLOW/HORIZONTAL GAS FURNACES FORM NO. G66-478 REV. 5 Supersedes Form No. G66-478 Rev. 4 80PJ SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] 80 PLUS A.F.U.E. UPF/HORIZONTAL GAS FURNACES Features The WeatherKing

More information

Rheem Classic Plus Series Upflow/Horizontal Ultra Low NOx Gas Furnace

Rheem Classic Plus Series Upflow/Horizontal Ultra Low NOx Gas Furnace Gas Furnaces Rheem Classic Plus Series Upflow/Horizontal Ultra Low NOx Gas Furnace R801T- Upflow/Horizontal Series 80% A.F.U.E. Input Rates 50-100 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated

More information

Rheem Classic Plus Series Upflow/Horizontal Gas Furnace

Rheem Classic Plus Series Upflow/Horizontal Gas Furnace Gas Furnaces Rheem Classic Plus Series Upflow/Horizontal Gas Furnace R801T- Upflow/Horizontal Series 80% A.F.U.E. Input Rates 50-125 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance

More information

Modular Variable Speed Air Handlers

Modular Variable Speed Air Handlers Modular Variable Speed Air Handlers Convertible Variable Speed Communicating Air Handlers - 2 1/2-5 Ton 2TEE3C31A1000A 2TEE3C37A1000A 2TEE3C40A1000A 2TEE3C49A1000A 2TEE3C65A1000A 4TEE3C31A1000A 4TEE3C37A1000A

More information

93% Gas Furnaces Single Stage

93% Gas Furnaces Single Stage Features and Benefits CONFIGURATIONS Upflow / Horizontal Downflow 93% Gas Furnaces Single Stage Form No. AA931A-100 (05/2012) HEAT EXCHANGER DESIGN Aluminized steel primary heat exchanger with crimped

More information

FG7S (C and L Series)

FG7S (C and L Series) TECHNICAL SPECIFICATIONS FG7S (C and L Series) High Efficiency/Direct Vent or Non Direct Vent Single Stage Condensing Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 92.1 AFUE Input 38,000-120,000

More information

KG7T (C and L Series)

KG7T (C and L Series) TECHNICAL SPECIFICATIONS KG7T (C and L Series) Two Stage, Fixed Speed ECM, Condensing Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 95.1 AFUE Input 60,000-120,000 Btuh The high efficiency

More information

95G1-E. Aluminized steel primary heat exchanger with crimped non-welded construction AL 29-4C Stainless steel secondary heat exchanger

95G1-E. Aluminized steel primary heat exchanger with crimped non-welded construction AL 29-4C Stainless steel secondary heat exchanger Single Stage - High Efficiency (Constant Torque) Motor 95% Gas Furnaces Features and Benefits CONFIGURATIONS Upflow / Horizontal Downflow 95G1-E Form No. D95G1-E-100 (10/2011) HEAT EXCHANGER DESIGN Aluminized

More information

AMS8 / ADSS8. Single-Stage Multi-Speed Gas Furnaces 80% AFUE. Heating Input: 40, ,000 BTU/h

AMS8 / ADSS8. Single-Stage Multi-Speed Gas Furnaces 80% AFUE. Heating Input: 40, ,000 BTU/h / ADSS8 Heating Input: 40,000 140,000 BTU/h Single-Stage Multi-Speed Gas Furnaces 80% AFUE Contents Nomenclature...2 Product Specifications...3 Dimensions...5 Airflow Data...7 Wiring Diagrams...10 Accessories...11

More information

Upflow, Upflow / Horizontal, Counterflow

Upflow, Upflow / Horizontal, Counterflow , / Horizontal, 90/92 Gas Furnace CG90/92 Features and Benefits HEAT EXCHANGER DESIGN Aluminized steel tapered S-curve design primary exchanger with crimped no weld construction for long life AL29-4C Stainless

More information

95G1E PRODUCT SPECIFICATIONS SINGLE STAGE CONSTANT TORQUE MOTOR VENTING INSTALLATION FEATURES WARRANTY CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER

95G1E PRODUCT SPECIFICATIONS SINGLE STAGE CONSTANT TORQUE MOTOR VENTING INSTALLATION FEATURES WARRANTY CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER 95G1E PRODUCT SPECIFICATIONS SINGLE STAGE CONSTANT TORQUE MOTOR FORM NO. 95G1E-100 (04/2016) VENTING Designed certified for direct (2-pipe) and non direct (1-pipe) applications Easily vented with PVC pipe

More information

VG7S (D and M Series) High Efficiency, Single Stage Condensing Upflow/Horizontal and Downflow Gas Furnace Models 95.0 AFUE 38, ,000 Btuh Input

VG7S (D and M Series) High Efficiency, Single Stage Condensing Upflow/Horizontal and Downflow Gas Furnace Models 95.0 AFUE 38, ,000 Btuh Input TECHNICAL SPECIFICATIONS VG7S (D and M Series) High Efficiency, Single Stage Condensing Upflow/Horizontal and Downflow Gas Furnace Models 95.0 AFUE 38,000-120,000 Btuh Input The high efficiency upflow

More information

Product Data. Convertible Air Handlers 1 1/2 5Ton

Product Data. Convertible Air Handlers 1 1/2 5Ton Product Data Convertible Air Handlers 1 1/2 5Ton TEM6A0B24H21SB TEM6A0B30H21SB TEM6A0C36H31SB TEM6A0C42H41SB TEM6A0C48H41SB TEM6A0D48H41SB TEM6A0C60H51SB TEM6A0D60H51SB The TEM6 series air handler is designed

More information

FG7T (A and K Series)

FG7T (A and K Series) TECHNICAL SPECIFICATIONS FGT (A and K Series) Two Stage, Variable Speed, High Efficiency Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 80 + AFUE Input 60,000-140,000 Btuh The high efficiency

More information

AMS8/ADSS8. Single-Stage. Heating Input: 40, ,000 BTU/h

AMS8/ADSS8. Single-Stage. Heating Input: 40, ,000 BTU/h Heating Input: 40,000 140,000 BTU/h /ADSS8 Single-Stage Multi-Speed Gas Furnaces 80% AFUE Standard Features Single-stage gas valve Durable Silicon Carbide ignitor Quiet, single-speed draft inducer Self-diagnostic

More information

95% Gas Furnaces. Single Stage - High Efficiency (Constant Torque) Motor. Features and Benefits 95G1-E CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER

95% Gas Furnaces. Single Stage - High Efficiency (Constant Torque) Motor. Features and Benefits 95G1-E CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER 95G1-E Features and Benefits CONFIGURATIONS 95% Gas Furnaces Single Stage - High Efficiency (Constant Torque) Motor Upflow / Horizontal Downflow Form No. R95G1-E-100 (01/2012) HEAT EXCHANGER DESIGN Aluminized

More information

KG7T (C and L Series)

KG7T (C and L Series) TECHNICAL SPECIFICATIONS KG7T (C and L Series) Two Stage, Fixed Speed ECM, Condensing Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 95.1 AFUE Input 60,000-120,000 Btuh The high efficiency

More information

TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY

TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY TECHNICAL SPECIFICATIONS KG7S (C and L Series) High Efficiency / Direct Vent or Non Direct Vent Condensing Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 92. AFUE Input 38,000-20,000 Btuh

More information

TECHNICAL GUIDE MODELS: P4HU 80 AFUE MULTI-POSITION GAS-FIRED FURNACES DESCRIPTION. WARRANTY 20-year limited warranty on the heat exchanger.

TECHNICAL GUIDE MODELS: P4HU 80 AFUE MULTI-POSITION GAS-FIRED FURNACES DESCRIPTION. WARRANTY 20-year limited warranty on the heat exchanger. 036-21047-001 Rev. A (4/00) DESCRIPTION These high efficiency, compact units employ induced combustion, reliable hot surface ignition and high heat transfer aluminized tubular heat exchangers. The units

More information

WFAR. Product Specifications 92.1 AFUE GAS FURNACE MULTIPOISE DESIGN

WFAR. Product Specifications 92.1 AFUE GAS FURNACE MULTIPOISE DESIGN 92.1 AFUE GAS FURNACE MULTIPOISE DESIGN WFAR Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification for individual products, go to

More information

TSTAT0101SC Recommended (sold separately)

TSTAT0101SC Recommended (sold separately) Up to 96% AFUE, Communicating, Two Stage Gas Furnace EASIER TO SELL Up to 96% AFUE, all models, all positions California NOx approved All Models have earned the ENERGY STAR Two stage heating operation

More information

95% Gas Furnaces A95-1E. Single Stage - High Efficiency (Constant Torque) Motor. Features and Benefits CONFIGURATIONS

95% Gas Furnaces A95-1E. Single Stage - High Efficiency (Constant Torque) Motor. Features and Benefits CONFIGURATIONS A95-1E 95% Gas Furnaces Single Stage - High Efficiency (Constant Torque) Motor Features and Benefits CONFIGURATIONS Upflow / Horizontal Downflow Form No. JA95-1E-100 (10/2011) HEAT EXCHANGER DESIGN Stainless

More information

FG7T (A and K Series)

FG7T (A and K Series) TECHNICAL SPECIFICATIONS FG7T (A and K Series), Smartlite Two Stage, Variable Speed, High Efficiency Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 80 + AFUE Input 60,000-140,000 Btuh The

More information

TECHNICAL GUIDE MODELS: G8T-UP 80 AFUE UPFLOW/HORIZONTAL GAS-FIRED FURNACES DESCRIPTION WARRANTY FEATURES Rev.

TECHNICAL GUIDE MODELS: G8T-UP 80 AFUE UPFLOW/HORIZONTAL GAS-FIRED FURNACES DESCRIPTION WARRANTY FEATURES Rev. TECHNICAL GUIDE MODELS: G8T-UP 80 AFUE UPFLOW/HORIZONTAL GAS-FIRED FURNACES 40-130 MBH INPUT HIGH-EFFICIENCY INDUCED COMBUSTION EFFICIENCY RATING CERTIFIED This product was manufactured in a plant whose

More information

WFSR. Product Specifications 95.5 AFUE GAS FURNACE MULTIPOISE DESIGN UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS) Heat Exchangers Warranty

WFSR. Product Specifications 95.5 AFUE GAS FURNACE MULTIPOISE DESIGN UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS) Heat Exchangers Warranty 95.5 AFUE GAS FURNACE MULTIPOISE DESIGN WFSR Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification for individual products, go to

More information

N9MPD Product Specifications

N9MPD Product Specifications Single Stage Furnace Multiposition FLEXIBILITY Dual certified venting (1 or 2 pipes) Direct Vent furnace 40 (1016mm) high with wider cabinets, for ease of installation Factory shipped as natural gas, with

More information

KG7S (A and K Series)

KG7S (A and K Series) TECHNICAL SPECIFICATIONS KG7S (A and K Series) High Efficiency Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 80+ AFUE Input 45,000-126,000 Btuh The high efficiency gas furnace may be installed

More information

92G1 PRODUCT SPECIFICATIONS SINGLE STAGE GAS FURNACE CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER CABINET DESIGN AIR DELIVERY SYSTEM CONTROLS VENTING

92G1 PRODUCT SPECIFICATIONS SINGLE STAGE GAS FURNACE CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER CABINET DESIGN AIR DELIVERY SYSTEM CONTROLS VENTING 92G1 PRODUCT SPECIFICATIONS SINGLE STAGE GAS FURNACE FORM NO. 92G1-100 (10/2018) CONFIGURATIONS Upflow/Horizontal Downflow HEAT EXCHANGER DESIGN Aluminized steel design primary heat exchanger with crimped

More information