CURBPAK AIR HANDLING UNITS ENGINEERING GUIDE
|
|
- Egbert Hudson
- 5 years ago
- Views:
Transcription
1 FORM EG2 (401) CURBPAK AIR HANDLING UNITS ENGINEERING GUIDE 00466VIP OUTDOOR AIR HANDLING UNITS
2 Table of Contents GENERAL DESCRIPTION... 3 Unit Description... 3 Outdoor Features... 3 Structural Performance... 4 Quality... 4 Flexibility... 5 Factory Installed Controls & Elec. Options... 7 Variable Air Volume Applications... 7 Factory-Packaged Controls and Motor Control Centers... 8 Factory-mounted End Devices in the AirPak Air-Handling Units... 9 Assurance of YORK Backing Segment Identification Unit Nomenclature Segment Availability Economizer Damper Arrangement QUICK SELECTION TABLES Coils Dimensions & Weights ENGINEERING DATA Forward Curved & Airfoil Fan & Motor Data Plenum Supply/Return Fan & Motor Data Plenum Return Fan & Motor Data Variable Inlet Vanes Operating Torques Coil Data Integral Face & Bypass Coil Data Filter Data Blender Data Fan and Motor Heat Air Unit Temperature Limitations Damper Sizes & Required Torque Humidifier Data Sound Attenuator Data Electric Heat Indirect Fired Gas Heater Turndown Options and Guidelines Insurance Options and Local Code Requirements Gas Pressure Requirements Gas Train UNIT SELECTION Selecting a CurbPak Air Handling Unit Reference Literature AIR PRESSURE DROP Altitude/Temp. Conversion Factors Instructions for Using Tables Static Pressure Schematics /8" Cooling & Dehumidifying Table /8" Heating & Sensible Cooling Table /2" Cooling & Dehumidifying Table /2" Heating & Sensible Cooling Table Steam Distributing Coil Table Filter Table Diffuser Table Air Blender Table TABLE OF CONTENTS PAGE PAGE Attenuator Table Fan Velocity Table Vertical Casing Pressure Table Electric Heat Table Inlet Damper Pressure Drop Tables SEGMENT DIMENSIONS Control Enclosure (CE) Supply Fan (FS) Plenum Supply Fan (FP) Cooling Coil (SC, MC, LC) Heating Coil (HC) Face & Bypass Damper (IB) Integral Face & Bypass Coil (IC) Filter (FF, AF, RF, BF, CF, HF) Mixing Box Inlet (MB) Return Fan Segment EE / FR Economizer Segment EE / MB Economizer / Fan Plenum Segment EE / FP(V) Economizer / Fan Plenum Segment EE / FP(H) Exhaust Fan Segment EE / FE Access (MA, LA, XA) Diffuser (DI) Sound Attenuator (AT) Humidifier (HM) Electric Heat (EH) Indirect Fired Gas (IG) Discharge Plenum (DP) End Flange (SS & EF) Air Blender (AB) Non-Standard (NS) PHYSICAL DATA CurbPak Overall Dim. & Weight Calculations Segment Weights Roof Curb Weights Full and Reduced Face Coil Weights Coil Connection Locations Water Coil Connection Locations Steam Coil Connection Locations Expansion Coil Connection Locations - Std Expansion Coil Connection Locations - Tall Pipe Chase Enclosure Inlet Cone Dimensions Unit & Coil Hand Selection Fan Segment Access Door Locations Power Wiring Options CurbPak Starter Wiring CurbPak Lighting and Power Wiring CurbPak AirMod Wiring Typical Electric Heater Wiring Diagram Sloped Curb Roof Curb Curb Detail Unit Base Rail Detail Pipe Chase Detail GUIDE SPECIFICATIONS YORK INTERNATIONAL
3 General Description FORM EG2 UNIT DESCRIPTION The YORK CurbPak is designed for rooftop applications. The design flexibility and quality construction of the CurbPak sets it apart from the competition. OUTDOOR FEATURES The CurbPak is specifically designed for outdoor applications. The outdoor design features of the CurbPak allow it to withstand the most severe environments. A rooftop unit is only as good as its roof. The CurbPak roof is sloped to eliminate standing water and its corrosive effects. In addition, the roof panels are fastened through standing seams and attached to the side walls. This eliminates the need for any screws through the skin of the roof, thus eliminating this as a possible source of leakage. On the YORK CurbPak, the roof overhangs the sidewalls and doors, allowing runoff water to drop freely, eliminating corrosive streaming down the sides of the unit. The sidewalls are also free of exposed holes, and joints are caulked and covered with U-shaped seamcaps to assure a tight, reliable seal. Internal stiffening assures a high resistance to wind loads. ROOF w/seam CAP DETAIL 00058VIP (27174 & 27194) All outside air and exhaust air openings are protected from the outside elements by rain hoods. The rain hoods assure that no wind-blown moisture can penetrate the unit casing. The rain hood design features a full-length, drip lip that prevents moisture from being drawn in the outside air intake. SIDE WALL PANELS SHOWING SEAM CAPS 27195A SIDE WALL AND ROOF DETAIL LD06028(7in) YORK INTERNATIONAL 3
4 General Description The CurbPak coil IAQ drain pan is sloped to minimize standing condensate, and offers a full two inches of insulation to give the pan the thermal protection it requires. RAIN HOOD 28072A(D) STRUCTURAL PERFORMANCE The CurbPak housing has been designed for maximum deflections 1/200 of panel length. Design criteria system static pressure include snow loading of 30 pound/ sq. ft. and wind load of 100 m.p.h. QUALITY DRAIN PAN DOUBLE SLOPE DRAIN PAN LINER 2" INSULATION CurbPak units are constructed entirely of double wall panels including the floor panels! Panels are insulated with a full two inches of insulation. Perforated lining is available in most segments to meet a variety of applications. The double wall design provides the highest quality of unit construction, while preventing erosion of the insulation fibers into the air stream. 1-1/4" DRAIN MPT CONNECTION SLOPED DRAIN PAN DETAIL 2" INSULATION LD06465 Access Doors The CurbPak access doors are also double wall construction. The doors feature a full-length stainless steel piano hinge. The use of positive action handles prevent locking if door is accidentally shut. These handles are used in unit sizes 65 through 400. For walk-in unit sizes 460 through 1030, all door latches have a single handle with multiple latch points. 2" DOUBLE WALL PANEL VERTICAL FRAME DOUBLE WALL FLOOR FLOOR SUPPORT 2" INSULATION BASE RAIL OPTIONAL CURB LD06464 LD00010 SIDE WALL & FLOOR DETAIL FOR UNIT SIZES CP65 TO CP305 SIDE WALL & FLOOR DETAIL FOR UNIT SIZES CP350 TO CP YORK INTERNATIONAL
5 FORM EG2 SUPPLY FAN SEGMENT CURBPAK SEGMENTS EXPOSED COIL SEGMENT FILTER SEGMENT INLET/ECONOMIZER SEGMENT WITH DWDI RETURN AIR FAN 25514A FLEXIBILITY For maximum flexibility the CurbPak is based on a segmented design concept. The unit construction however, is unitized. Each unit is engineered and built as a single assembly for greater unit integrity. The segmental design concept permits the designer to optimize and customize segments that will best meet the application. The unit is then engineered and built as a single piece, not a collection of pre-designed and prebuilt modules. STAINLESS STEEL CONTINUOUS TYPE HINGE 2" INSULATION 18 GA. GALVANIZED STEEL OUTER PANEL STANDARD 2" WALL CurbPak units are designed and built to ship as a single piece except sizes 860 and This minimizes installation time and cost. Units can however be shipped in multiple pieces to accommodate various shipping and job site requirements. Fans Double-Width, Double-Inlet (DWDI) fans and Single Width, Single-Inlet (SWSI) plenum fans are available for supply and return air fans. The plenum fan segments can accommodate multiple duct outlets, thus reducing the amount of field duct work and transitions. All of the CurbPak fan assemblies are internally isolated. Seismic isolation is available as an option. VIEW PORT 20 GA. GALVANIZED STEEL LINER ALUMINUM FRAME ACCESS DOOR DETAIL LD06466 DWDI FAN w/variable INLET VANES 25586B YORK INTERNATIONAL 5
6 General Description 27029A 27027A 25536A STANDARD COIL w/pipe CHASE & ACCESS PANEL (Piping by others) Optional pipe chase depths are available A 27132A(D) THROWAWAY, PLEATED, BAG & HEPA FILTERS Filters CurbPak filter segments can be customized to meet any filtration requirement. Bag, Rigid and HEPA filters can be provided to meet stringent filtration requirements. Carbon filters are available for applications involving odor removal. Economizer INTEGRAL FACE & BYPASS (IFB) COIL Coils 00498VIP A variety of coils are available to meet every application. Both 1/2" and 5/8" coils are available for chilled water, hot water and direct expansion applications. A 1" inch outside diameter Steam Distributing Coil can be selected for heating applications. For the maximum amount of freeze protection, the YORK CurbPak can be provided with an integral face and bypass coil. YORK will furnish and factory install coils manufactured by the L.J. WING Company (TM). L.J. WING has set the standard for freeze protection with unsurpassed quality and design. Wing Coils are available with horizontal (IFB) and vertical (VIFB) tubes, depending upon unit size. Economizer segments are available to provide the maximum benefits of free-cooling during off peak operation. All of the CurbPak Economizer Segments can accommodate 100% outside air, exhaust air and return air. Return and exhaust fans are available to meet the needs of varying building pressurization requirements. Additional Segments A variety of other segments are available to match individual applications. The CurbPak is available with factory installed air blenders, sound attenuators, electric heat, face and bypass, humidifiers, diffusers, discharge plenums, access segments and indirect-fired gas burner segments. Other segments can be provided to accommodate special requirements. 6 YORK INTERNATIONAL
7 FORM EG2 FACTORY INSTALLED CONTROLS AND ELECTRICAL OPTIONS YORK has the capability to furnish units with factory installed singlepoint power motor starter panels, disconnects, marine lights, sensors, actuators or complete unit automation. Factory installed wiring greatly reduces installation time and cost. Factory installed inverters, the YORK Air-Modulator, provide the most efficient and cost effective VAV control in a complete factory package. Factory mounted inverters not only save field labor, but it also assures proper fan balance for vibration free operation. While most fans are balanced for a single speed, fans with inverters are factory balanced to operate over the entire RPM range. VARIABLE AIR VOLUME APPLICATIONS Factory mounted variable frequency drives (YORK Air-Modulator) and variable inlet vanes are available with the YORK CurbPak for Variable Air Volume Applications. YORK Air-Modulator (AM): YORK s Variable Frequency Drive, the AM, offers the most efficient means of fan control for variable air volume systems. The Air-Modulator varies the speed of the fan to match the VAV load requirements. The AM takes maximum advantage of the relation between fan speed and fan horsepower. With the AM, any reduction in fan speed results in a cubic reduction in fan horsepower. For example, a 10% speed reduction results in a 27% fan horsepower reduction! The AM offers the following benefits over variable inlet vanes and discharge dampers: Extended Equipment Life soft start of motor and fan. Quieter Fan Operation fan operating at reduced speed and constant line of efficiency. Eliminates need for motor starter panels. Improved system control and response DDC controls with LED digital display. Proven reliability vip AM LOCATED IN A NEMA 3R ENCLO- SURE TYPICALLY MOUNTED ON SUP- PLY/RETURN FAN SEGMENTS Variable Inlet Vanes Variable inlet vanes are another method of energy efficient fan control. While the fan runs at a constant speed, the inlet vanes modulate the air entering the fan. This produces a reduced air volume resulting in lower operating horsepowers vip INSIDE VIEW OF THE AM. AVAILABLE WITH TRANSFORM LIGHT/OUTLET BOX YORK INTERNATIONAL 7
8 General Description *OPTIONAL MOUNTING LOCATIONS AVAILABLE OUTSIDE AIR TEMPERATURE SENSOR *OPTIONAL (NEMA 3R) CONTROL ENCLOSURE DAMPER ACTUATOR (O.A.) OPTIONAL (NEMA 3R) MOTOR CONTROL PANEL MIXED AIR DIFFERENTIAL PRESSURE TRANSDUCER RETURN AIR TEMP. SENSOR DAMPER ACTUATOR (R.A.) MIXED AIR TEMPERATURE SENSOR BUILDING STATIC PRESSURE TRANSDUCER DUCT STATIC PRESSURE TRANSDUCER DISCHARGE AIR TEMPERATURE SENSOR LOW LIMIT CONTROL FILTER DIFFERENTIAL PRESSURE SWITCH LD06741 TYPICAL CURBPAK w/factory-packaged CONTROLS or SINGLE POINT MOTOR CONTROL CENTER FACTORY-PACKAGED CONTROLS AND MOTOR CONTROL CENTERS Factory Engineered YORK Factory-Packaged Controls with Single-Point Motor Control Center assure you of getting a complete factory-engineered system no surprise, no hassle, and no compromise. The control systems are designed with each specific piece of equipment in mind. This assures you that the system will control, monitor and diagnose only those points that are necessary to maintain optimum performance. Reduce Costs YORK Factory-Packaged End Devices wired to a Motor Control Center reduce costs by taking the guesswork out of control installation. Each device is mounted in the factory as the equipment is being manufactured. There are no worries over job site locations or conditions. Factory labor means faster assembly and lower first cost. Quality Control YORK Factory-Packaged End Devices wired to a Motor Control Center assure you of getting a higher quality control system, right from the factory. The control system is designed and mounted following the same stringent quality control standards by which the units are built. Full Service Support Because YORK Factory-Packaged End Devices wired to a Motor Control Center are an integral part of the equipment, who better to troubleshoot and service the system than a professional YORK Service technician. The YORK Service technician knows not only the equipment and the hardware, but also has a working knowledge of equipment application and operation. Every unit is backed by this kind of professional support. 8 YORK INTERNATIONAL
9 FORM EG2 FACTORY-MOUNTED END DEVICES IN THE CURBPAK AIR-HANDLING UNITS FACTORY-MOUNTED END DEVICES OVERVIEW The YORK Factory-mounted End Device Package consists of end devices that are pre-engineered; factory installed, wired and commissioned to provide a higher level of quality and consistency than can be achieved by installation on the job site. All end devices are mounted in the factory, on the assembly line, where there is complete access to all air-handling segments. No more trying to get inside of the unit, or taking it apart on the job site to install end devices. The end devices can be ordered 2 ways; mounted with no wiring or mounted and wired to an external control enclosure on the air-handling unit. All units that have end devices mounted and wired will have E.T.L. rating. CONTROL ENCLOSURE On all units ordered with Factory-mounted End Devices and wiring all end devices will be wired to a control enclosure that is mounted on the unit. On outdoor units the enclosure will be a NEMA 3R enclosure. The enclosure will consist of secondary transformers sized to handle all actuators, valves and end devices installed in the air-handler, control relays, and a low-limit reset button. On VAV air-handling units, a duct static pressure transducer will be mounted inside the enclosure and the tubing for the low and high side of the transducer will be piped to barbed fittings located on the outside of the enclosure. A terminal strip will be provided inside the control enclosure for all low voltage field terminations. The control enclosure will be E.T.L. listed. END DEVICE FACTORY COMMISSIONING Every end device that is Factory-mounted and wired will go through a detailed automated commissioning process to ensure that every end device functions properly before the air-handling unit leaves the factory. As part of this commissioning process, a report will be generated and this report will ship with the unit. The extensive commissioning the end devices go through at the factory would be virtually impossible to duplicate in the field. Through Cables on Shipping Splits On all air-handling units with shipping splits, cables with field connectors will be supplied. The operator connects the automated commissioning tester to the segment being tested and then connects test plugs to the through cables. The automated commissioning tester then performs a test to verify that there are no open or shorts in the through cables and that all polarity is correct. On verification of this test, the automated commissioning tester records a pass condition. CONTROL ENCLOSURE FOR FACTORY-MOUNTED END DEVICES WIRING SCHEMATICS On air-handling units that are ordered with Factorymounted End Devices and wiring, a wiring schematic will be attached to unit. This schematic will include the following detail: A pictorial layout of the air-handling unit showing what devices are mounted in each segment. A wiring schematic showing all interlocking wiring to starter, disconnects and VFDs. Wiring of all end devices back to the circuit board that is located inside the control enclosure. A bill of material table that shows the YORK acronym and the corresponding part number. These wiring schematics are available to customers in electronic.dxf format vip Components Include: 120VAC to 24VAC transformers (3) Relays for fan start/stop & low-limit reset circuit Circuit board for field & factory terminations Low-limit reset button Knockouts will be provided for customer wiring Hinged front cover can be lifted off after opening 2" YORK INTERNATIONAL 9
10 General Description 27598A YORK FACTORY SERVICE YORK carries the burden of single-source responsibility since YORK packages the total system, including custom air handlers, chillers, controls, variable-air-volume boxes and building automation systems. For added peace of mind, YORK offers Inspection Only, Preventive Maintenance and Inspection, or Total Service Contracts to meet your financing and management requirements. YORK service can also provide certified technicians available locally for factory start-up, drawing from over 700 factory-trained service technicians in 100 strategically-located offices nationwide a capability not offered by independent manufacturers. FULL SERVICE SUPPORT ASSURANCE OF YORK BACKING With every CurbPak system, you get the support and resources that come from dealing with a worldwide manufacturer YORK. You are not tied to the limitations of a regional supplier. Instead, you get the flexibility being able to design in one part of the country, and buy and install in another location. Because YORK Factory-mounted End Devices and Motor Control Center are an integral part of the equipment, who better to troubleshoot and service the system than a professional YORK Service Technician. The YORK Service technician knows not only the equipment and the hardware, but also has a working knowledge of equipment application and operation. Every unit is backed by this kind of professional support. 10 YORK INTERNATIONAL
11 FORM EG2 This Page Intentionally Left Blank. YORK INTERNATIONAL 11
12 General Description SEGMENT IDENTIFICATION Supply Fan Segments: FS - Supply Fan Fan Types: Forward Curved Fan Standard Class II Airfoil Standard Class II FP - SWSI Supply Plenum Fan Fan Types: Airfoil Class II Backward Inclined Standard Coil Segments: SC - Short Cooling Coil (13") MC - Medium Cooling Coil (20") LC - Long Cooling Coil (27-3/8") HC - Heat Only, (8") IC - Heat Only, Integral Face & Bypass Coil Filter Segments: FF - Flat Filter (2" & 4") AF - Angle Filter (2") RF - Rigid Filter (12") BF - Bag Filter (21" & 30") CF - Carbon Filter HF - HEPA Filter Inlet Segments: MB - Inlet w/dampers (0%, 30% or 100% OA 0% or 100% RA) EE - Economizer w/dampers (100% OA/RA/EA) Return Fan Segments: FR - DWDI FC or AF Return Fan FP - SWSI Horz./Vert. Plenum Return Fan FE - DWDI FC Exhaust Fan Accessory Segments: MA, LA and XA - Access AB - Air Blender IB - Face & Bypass Damper CE - Control Enclosure SS - Shipping Split DI - Diffuser DP - Discharge Plenum EF - End Flange EH - Electric Heat IG - Gas Heat HM - Humidifier NS - Non-Standard AT - Sound Attenuator UNIT NOMENCLATURE CP 350 FC UNIT TYPE FAN TYPE CurbPak DWDI *FC (Forward Curved) DWDI *AF (Airfoil) UNIT SIZE SWSI **AF (Airfoil) SWSI **BI (Backward Inclined) *Double - Width, Double - Inlet **Single - Width, Single - Inlet YORK INTERNATIONAL
13 FORM EG2 SEGMENT AVAILABILITY LD06263 ECONOMIZER DAMPER ARRANGEMENTS EE 1 EE 2 EE 3 EE 4 50% OA 100% OA TOP VIEWS MD MD MD 50% OA 100% EA 100% OA 100% OA SIDE VIEWS 100% RA USED WITH EE-MB ALL UNIT SIZES EE-FP(V) UNITS CP65 THROUGH CP305 ONLY USED WITH EE-FR ALL UNIT SIZES EE-FP(H) ALL UNIT SIZES USED WITH EE-FE CP EE-FP(V) CP USED WITH EE-FE CP YORK INTERNATIONAL 13 LD06589
14 This Page Intentionally Left Blank. 14 YORK INTERNATIONAL
15 Quick Selection Tables FORM EG2 CDW / CDX COILS (5/8" O.D.) UNIT SIZE FACE VELOCITY fpm COIL COIL FACE DIMENSIONS (in.) AREA cfm FH FL (sq. ft.) 65 2,745 2,898 3,050 3,203 3,355 3, ,645 3,848 4,050 4,253 4,455 4, ,545 4,798 5,050 5,303 5,555 5, ,445 5,748 6,050 6,353 6,655 6, ,245 7,648 8,050 8,453 8,855 9, ,045 9,548 10,050 10,553 11,055 11, ,845 11,448 12,050 12,653 13,255 13, ,645 13,448 14,050 14,753 15,455 16, ,638 16,506 17,375 18,244 19,113 19, ,244 19,257 20,271 21,284 22,298 23, ,363 21,494 22,625 23,756 24,888 26, ,756 25,076 26,396 27,716 29,035 30, ,544 32,241 33,938 35,634 37,331 39, ,531 40,672 42,813 44,953 47,094 49, ,238 48,806 51,375 53,944 56,513 59, BDW / BDX COILS (1/2" O.D.) UNIT SIZE FACE VELOCITY fpm COIL COIL FACE DIMENSIONS (in.) AREA cfm FH FL (sq. ft.) 65 2,835 2,993 3,150 3,308 3,465 3, ,735 3,943 4,150 4,358 4,565 4, ,680 4,940 5,200 5,460 5,720 5, ,625 5,938 6,250 6,563 6,875 7, ,515 7,933 8,350 8,768 9,185 9, ,360 9,880 10,400 10,920 11,440 11, ,250 11,875 12,500 13,125 13,750 14, ,140 13,870 14,600 15,330 16,060 16, ,188 16,031 16,875 17,719 18,563 19, ,719 18,703 19,688 20,672 21,656 22, ,250 21,375 22,500 23,625 24,750 25, ,625 24,938 26,250 27,563 28,875 30, ,375 32,063 33,750 35,438 37,125 38, ,438 40,573 42,708 44,844 46,979 49, ,125 48,688 51,250 53,813 56,375 58, YORK INTERNATIONAL 15
16 Quick Selection Tables (continued) DIMENSIONS AND WEIGHTS UNIT SIZE HEIGHT WIDTH SEGMENT L = LENGTH OF SEGMENT IN THE DIRECTION OF AIRFLOW (IN.) FS 3 SUPPLY FAN L W/AF bs SUPPLY FAN L W/FC lbs FP 3 PLENUM SUPPLY L FAN lbs MA 18" ACCESS L lbs LA 24" ACCESS L lbs XA 30" ACCESS L lbs SC SHORT COIL (13") L (6 Row/8 FPI BDW FF Coil) lbs MC MEDIUM COIL (20") L (8 Row/8 FPI BDW FF Coil) lbs LC LONG COIL (27-3/8") L (2 & 4 Row/8FPI/BDW FF Coil) lbs HC HEATING COIL L (1 Row/8 FPI BDW FF Coil) lbs IC (2 Row IFB Wing Coil) L N/A N/A N/A N/A N/A N/A N/A WING lbs COILS (4 Row IFB Wing Coil) L N/A N/A N/A N/A N/A N/A N/A lbs (1 Row VIFB Wing Coil) L N/A N/A N/A lbs (2 Row VIFB Wing Coil) L N/A N/A N/A lbs (3 Row VIFB Wing Coil) L N/A N/A N/A lbs EH ELECTRIC HEAT L " lbs ELECTRIC HEAT L " lbs ELECTRIC HEAT L " lbs IG INDIRECT L N/A N/A N/A N/A FIRED GAS HEAT lbs HM HUMIDIFIER L lbs FF FLAT FILTER (2", 4") L lbs AF ANGLE FILTER (2") L lbs RF RIGID FILTER L lbs BF BAG FILTER (21") L lbs BAG FILTER (32") L lbs CF CARBON FILTER L lbs HF HEPA FILTER L lbs MB INLET L (30% OA & 100% RA) lbs MB INLET L (100% OA & 100% RA) lbs MB INLET L (100% OA & 0% RA) lbs MB INLET L (0% OA & 100% RA) lbs YORK INTERNATIONAL
17 FORM EG2 DIMENSIONS AND WEIGHTS SEGMENT UNIT SIZE HEIGHT WIDTH L = LENGTH OF SEGMENT IN THE DIRECTION OF AIRFLOW (IN.) AB AIR BLENDER L lbs AT SOUND ATTENUATOR L (3FT) lbs SOUND ATTENUATOR L (5FT) lbs SOUND ATTENUATOR L (7FT) lbs DIF DIFFUSER L lbs DP DISCHARGE L PLENUM lbs EF END FLANGE L lbs IB FACE & BYPASS L DAMPER lbs CE CONTROL CABINET L lbs SS SHIPPING L SPLIT lbs EE-FR INLET/ECONOMIZER L W/ RETURN FAN lbs EE-MB INLET/ECONOMIZER L NO FAN lbs EE-FP(V) INLET/ECONOMIZER L N/A VERTICAL PLENUM FAN lbs. N/A EE-FP (H) INLET/ECONOMIZER L HORZ. PLENUM FAN lbs EE-FE INLET/ECONOMIZER L FC EXHAUST FAN lbs LC PIPE CHASE lbs MC PIPE CHASE lbs SC PIPE CHASE lbs " NS lbs HC PIPE CHASE lbs NOTES: 1. Weights are shipping weights not operating weights. 2. For coil segments, the dimensions in (") represents the coil space available. 3. Weights include the largest available motor and largest Class II fans. 4. Certain items (e.g. coil connections, door handles, mounting feet, etc.) may extend beyond the cabinet dimensions. 5. MB and EE / FR, FP, FE weights include rain hood. YORK INTERNATIONAL 17
18 Engineering Data FORWARD CURVED / AIRFOIL FAN AND MOTOR DATA FAN MAX. MAX. FAN OUTLET UNIT VIV MOTOR MOTOR AREA SIZE TYPE SIZE OPTION HP FRAME (sq. ft) 65 FC 10 X 10 N/A T 1.03 AF 12 N/A T FC 10 X 10 N/A T 1.03 AF 12 N/A T 1.45 FC 10 X 10 N/A T FC 12 X 12 N/A T 1.45 FC 12 X 12 (L) YES T 1.45 AF 15 YES T 2.04 FC 12 X 12 N/A T 1.45 FC 12 X 12 (L) YES T FC 15 X 15 N/A T 2.04 AF 12 N/A T 1.45 AF 15 YES T 2.04 FC 15 X 15 N/A T 2.04 FC 15 X 15 (L) YES T FC 18 X 18 N/A T 2.86 FC 18 X 18 (L) YES T 2.86 AF 15 YES T 2.04 AF 18 YES T 2.86 FC 18 X 18 N/A T FC 18 X 18 (L) YES T 2.86 AF 15 YES T 2.04 AF 18 YES T 2.86 FC 20 X 20 N/A T FC 20 X 20 (L) YES T 4.25 AF 18 YES T 2.86 AF 20 YES T 4.38 FC 20 X 20 N/A T FC 20 X 20 (L) YES T 3.25 AF 20 YES T 4.38 AF 22 YES T 5.50 FC 22 X 22 N/A T FC 22 X 22 (L) YES T 5.20 AF 22 YES T 5.50 AF 25 YES T 6.90 FC 25 X 25 N/A T FC 25 X 25 (L) YES T 6.80 AF 25 YES T 6.90 AF 28 YES T 8.70 FC 25 X 25 N/A T 6.90 FC 27 X 27 (L) YES T FC 28 X 28 N/A T 8.10 AF 28 YES T 8.67 AF 32 YES T FC 28 X 28 N/A T 8.67 FC 30 X 30 (L) YES T FC 32 X 32 N/A T AF 28 YES T 8.67 AF 32 YES T YORK INTERNATIONAL
19 FORM EG2 FORWARD CURVED / AIRFOIL FAN AND MOTOR DATA UNIT FAN VIV SIZE SIZE TYPE OPTION MAX. MAX. FAN OUTLET MOTOR MOTOR AREA HP FRAME (sq. ft) FC 28 X 28 N/A T 8.67 FC 30 X 30 (L) YES T 9.40 FC 32 X 32 N/A T AF 32 YES T AF 36 YES T FC 30 X 30 (L) YES T 9.40 FC 32 X 32 N/A T FC 33 X 33 (L) YES T FC 36 X 36 N/A T AF 36 YES T AF 40 YES T FC 36 X 36 N/A T FC 36 X 36 (L) YES T FC 40 X 40 N/A T AF 40 YES T AF 44M YES T AF 49M YES T FORWARD CURVE EXHAUST FAN AND MOTOR DATA FE UNIT SIZE FAN TYPE MAX. MAX. FAN OUTLET SIZE MOTOR MOTOR AREA HP FRAME (sq. ft) 350 FC 22 X T FC 25 X T FC 28 X T FC 28 X T FC 28 X T FC 32 X T FC 32 X T YORK INTERNATIONAL 19
20 Engineering Data PLENUM SUPPLY / RETURN FAN AND MOTOR DATA FP(S) & FP(H) SWSI (AF) PLENUM FANS UNIT FAN MAX MAX MOTOR SIZE TYPE SIZE MOTOR HP FRAME 65 BI T 85 BI T BI T 105 BI T 125 BI T AF T AF T 170 AF T AF T AF T 215 AF T AF T AF T 250 AF T AF T AF T 305 AF T AF T AF T 350 AF T AF T AF T AF T 400 AF T AF T AF T AF T 460 AF T AF T AF T 530 AF T AF T AF T AF T 680 AF T AF T 860 AF T AF T AF T 1030 AF T AF T NOTES: 1. Units with SWSI fans are not within the scope of ARI Certification (Standard 430). 2. All SWSI fans are CL2. PLENUM RETURN FAN AND MOTOR DATA FP(V) UNIT SWSI (AF) PLENUM FANS SIZE FAN MAX MAX MOTOR TYPE SIZE MOTOR HP FRAME 65 N/A N/A N/A N/A 85 BI T 105 BI T 125 AF T 170 AF T 215 AF T 250 AF T 305 AF T 350 AF T 400 AF T 460 AF T 530 AF T 680 AF T 860 AF T 1030 AF T NOTE: 1. Units with SWSI fans are not within the scope of ARI Certification (Standard 430). 20 YORK INTERNATIONAL
21 FORM EG2 VARIABLE INLET VANES OPERATING TORQUES FORWARD CURVED (IN. LBS.) RPM FAN SIZES 12 x x x x x x x x x x NOTE: Shaded area indicates an area where the RPM is below minimum or exceeds the Class II limits. AIRFOIL (DWDI) (IN. LBS.) RPM FAN SIZES NOTE: Shaded area indicates an area where the fan exceeds the Class II limits. YORK INTERNATIONAL 21
22 Engineering Data PLENUM FAN (IN. LBS.) VARIABLE INLET VANES OPERATING TORQUES RPM FAN SIZE NOTE: 1. Shaded area indicates an area where the fan exceeds the Class II limits. 22 YORK INTERNATIONAL
23 Engineering Data Coils FORM EG2 COIL DATA FREE FLOW COILS TURBOFIN COILS NON-FREEZE COILS BDW UNIT 1/2" DIA. TUBES CDW 5/8" DIA. TUBES SDC 1" DIA. TUBES (SDC TYPES) SIZE Full Face Reduced Face Full Face Reduced Face Full Face Reduced Face 1 (Quantity) Area 1 (Quantity) Area 1 (Quantity) Area 1 (Quantity) Area 1 (Quantity) Area 1 (Quantity) Area FH x FL (sq.ft.) FH x FL (sq.ft.) FH x FL (sq.ft.) FH x FL (sq.ft.) FH x FL (sq.ft.) FH x FL (sq.ft.) (1) (1) (1) (1) (1) (1) x x x x x x 36.0 (1) (1) (1) (1) (1) (1) x x x x x x 48.0 (1) (1) (1) (1) (1) (1) x x x x x x 60.0 (1) (1) (1) (1) (1) (1) x x x x x x 36.0 (1) (1) (1) (1) (1) (1) x x x x x x 48.0 (1) (1) (1) (1) (1) (1) x x x x x x 60.0 (1) (1) (1) (1) (1) (1) x x x x x x 72.0 (1) (1) (1) (1) (1) (1) x x x x x x 84.0 (2) (1) (2) (2) (2) (1) x x x x x x 72.0 (2) (1) (2) (2) (2) (1) x x x x x x 84.0 (2) (2) (2) (2) (2) (2) x x x x x x 72.0 (2) (2) (2) (2) (2) (2) x x x x x x 84.0 (2) (2) (2) (2) (2) (2) x x x x x x (2) (2) (2) (2) (3) (2) x x x x x x (2) (2) (2) (2) (3) (2) x x x x x x NOTE: 1. (Quantity) = Connections per Unit (1) = 1 set of connections (1 supply, 1 return) (2) = 2 set of connections (2 supply, 2 return) (3) = 3 set of connections (3 supply, 3 return) FH x FL = Finned Height (Inches) x Finned Length (Inches) YORK INTERNATIONAL 23
24 Engineering Data Coils INTEGRAL FACE AND BYPASS COIL DATA UNIT SIZE HORIZONTAL TUBE COILS (IFB) MAX. OUTLET L.J. WING cfm AREA MODEL 65 N/A N/A N/A 85 4, lfb-a , lfb-a N/A N/A N/A 170 8, IFB-C , lfb-d , lfb-d , lfb-d , IFB-F , IFB-F N/A N/A N/A 530 N/A N/A N/A 680 N/A N/A N/A 860 N/A N/A N/A 1030 N/A N/A N/A NOTE: 1. All coil information used w/permission from L.J. Wing 2. Model numbers indicated are for two (2) row coils, 1 section. 3. All IFB coils have side coil connections. 4. Maximum cfm is based on 800 fpm x outlet area. VERTICAL TUBE COILS (VIFB) UNIT SIZE MAXIMUM OUTLET L.J. WING cfm AREA MODEL 65 N/A N/A N/A 85 N/A N/A N/A 105 N/A N/A N/A 125 4, VA , VA , VA , VA , VA , VC , VC , VE , VE , VE , VE , VE-12 NOTE: 1. All coil information used w/permission from L.J. Wing 2. Model numbers indicated are for one (1) row coils. 3. All VIFB coils have center coil connections. 4. Maximum cfm is based on 900 fpm x outlet area. 24 YORK INTERNATIONAL
25 Engineering Data FORM EG2 FILTER DATA FLAT FILTER (FF), RIGID FILTER (RF), BAG FILTER (BF) & HEPA FILTER (HF) SEGMENTS FILTER SIZES AND QUANTITIES PER UNIT SIZE UNIT SIZE Area (sq.ft.) Filter 12 x Size 24 x NOTES: 1. See the filter configurations below for specific filter arrangements. 2. Filters are side-loaded, except when in blow through arrangement they are either front or rear loaded. HEPA will always be front loaded. 3. The number in ( ) defines how many rows high with that particular filter pattern. LD06264 YORK INTERNATIONAL 25
26 Engineering Data FILTER DATA ANGLE FILTER SEGMENTS (AF) FILTER SIZES AND QUANTITIES PER UNIT SIZE UNIT SIZE Area (sq.ft.) Filter 12 x Size 24 x NOTES: 1. See the filter configurations below for specific filter arrangements. 2. Filters are side-loaded. 3. The number in ( ) defines how many rows high with that particular filter pattern. LD YORK INTERNATIONAL
27 FORM EG2 FILTER DATA 1" CARBON TRAY FILTER SEGMENTS (CF) FILTER SIZES AND QUANTITIES PER UNIT SIZE UNIT SIZE Area (sq.ft.) Filter 12 x Size 24 x Lbs Carbon NOTES: 1. See the filter configurations below for specific filter arrangements. 2. Filters are side-loaded. 3. Avoid placing carbon filters in high humidity areas. 4. Optional 4" flat filters are available upstream. 5. The number in ( ) defines how many rows high with that particular filter pattern. LD06266 YORK INTERNATIONAL 27
28 Engineering Data BLENDER DATA UNIT TOTAL AREA SIZE (sq. ft.) FAN AND MOTOR HEAT (MBH) HP FAN MOTOR FAN FAN AND FAN MOTOR / AIR UNIT TEMPERATURE LIMITATIONS Motors with Class F Insulation 140 F Motors with Class B Insulation 104 F Power Wiring 140 F Controls & Control Wiring F Prefilters 150 F High Efficiency Filters 200 F Fan Bearings 120 F (FC), 180 F (AF) Gasketing 200 F DAMPER LEAKAGE DAMPER ULL* DAMPER ULL* DAMPER LOW LEAK DAMPER WIDTH LEAKAGE cfm/sq. FT. LEAKAGE cfm/sq. FT. LEAKAGE cfm/sq. FT. 1" 4" 1" W.G NOTE: All damper banks are made up from maximum 48" wide sections. * Ultra-low leak EXAMPLE: CP 350 EE/FR Outside Air Damper Standard Construction HEIGHT 68.0 WIDTH 43.0 AREA 20.3 Leakage 20.3 sq. ft. x 3.7 cfm / sq. ft. = 75.1 cfm 28 YORK INTERNATIONAL
29 FORM EG2 DAMPER SIZES AND REQUIRED TORQUE MB Segment 100% Return Air (RA) 30% Outside Air (OA) 100% RA Individual 30% OA Individual Unit Damper Actual Dimensions Damper Damper Actual Dimensions Damper Size Width Height Area Torque Width Height Area Torque % OA Individual Unit Damper Actual Dimensions Damper Size Width Height Area Torque ACTUATOR DESCRIPTION 24VAC, 0-10VDC CONTROL, DIR. COUP., 266 ELECTRIC (*) 24VAC, 0-10VDC CONTROL, DIR. COUP., 133 PNEUMATIC 8-13 PSIG SPRING RANGE NOTE: mA control signal can be easily installed in the field with a resistor and simple wiring. NOTES: 1. Torque required to achieve maximum leakage performance. 2. Torques are based on 1 inch wg pressure differential. 3. Damper performance is based on AMCA 500 test setup 5.4/ Maximum damper face velocity is 2000 fpm. 5. Torques are configured for ULL dampers. To achieve LL dampers: Area of damper multiplied by 5. YORK INTERNATIONAL 29
30 Engineering Data EE 1 - MB EE 1 - MB SEGMENT ECONOMIZER WITHOUT RETURN FAN 100% EXHAUST AIR (EA) 100% OUTSIDE AIR (OA) 100% RETURN AIR (RA) 100% EA Individual 50% OA (Each Side) Individual 100% Mixing Damper Individ. Unit Damper Actual Dim. Damper Damper Actual Dim. Damper Damper Actual Dim. Damper Size Width Height Area Torque Width Height Area Torque Width Height Area Torque EE 2 - FR, EE 2 - FP(H) EE 2 - FR SEGMENT ECONOMIZER WITH RETURN FAN EE 2 - FP(H) ECONOMIZER WITH HORIZONTAL RETURN PLENUM FAN 100% EXHAUST AIR (EA) 100% OUTSIDE AIR (OA) 100% RETURN AIR (RA) 100% EA Individual 100% OA Individual 100% Mixing Damper Individ. Unit Damper Actual Dim. Damper Damper Actual Dim. Damper Damper Actual Dim. Damper Size Width Height Area Torque Width Height Area Torque Width Height Area Torque * * * * * * * * * * ** ** ** ** NOTES: See notes on page 29. * 2 Dampers Stacked ** 3 Dampers Stacked ELECTRIC PNEUMATIC ACTUATOR DESCRIPTION 24VAC, 0-10VDC CONTROL, DIR. COUP., 266 (*) 24VAC, 0-10VDC CONTROL, DIR. COUP., PSIG SPRING RANGE NOTE: mA control signal can be easily installed in the field with a resistor and simple wiring. 30 YORK INTERNATIONAL
31 FORM EG2 EE 1, EE 3 - FP(V) ECONOMIZER WITH VERTICAL RETURN PLENUM FAN 100% RETURN AIR (RA) 50% OUTSIDE AIR (OA) 100% EXHAUST AIR (EA) 100% RA Damper Individual 50% OA Individual 100% EA Individ. Unit Damper Actual Dim. Damper Damper Actual Dim. Damper Damper Actual Dim. Damper Size Width Height Area Torque Width Height Area Torque Width Height Area Torque EE 1 - FP (V) 65 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A EE 3 - FP (V) NOTE: FP (V) and EA is same as OA and RA. EE 1 and EE 3 - FP(V) EE 4 and EE 3 - FE EE 4, EE 3 - FE ECONOMIZER WITH EXHAUST FAN 100% RETURN AIR (RA) 100% OUTSIDE AIR (OA) 100% EXHAUST AIR (EA) 100% RA Individual 100% OA Damper Individual 100% EA Individ. Unit Damper Actual Dim. Damper Damper Actual Dim. Damper Damper Actual Dim. Damper Size Width Height Area Torque Width Height Area Torque Width Height Area Torque EE 4 - FE N/A N/A N/A N/A N/A N/A N/A N/A EE 3 - FE N/A N/A N/A N/A N/A N/A N/A NOTE: EA is Barometric; no actuator required. See notes on page 29. ELECTRIC PNEUMATIC ACTUATOR DESCRIPTION 24VAC, 0-10VDC CONTROL, DIR. COUP., 266 (*) 24VAC, 0-10VDC CONTROL, DIR. COUP., PSIG SPRING RANGE NOTE: mA control signal can be easily installed in the field with a resistor and simple wiring. YORK INTERNATIONAL 31
Complete HVAC Capability
Air Handling Units Brochure 1110 January 2006 Complete HVAC Capability MEA Horizontal Draw-Thru to Size 65 Vertical Draw-Thru to Size 50 1000 to 60,000 CFM Forward Curved or Airfoil Wheels Inlet Vane Option
More informationSubmittal DIMENSIONS SIZE FAN SIZE L W H C D E F G J K [406] [508] 25 [635] [406] 16 [406] 16 [406] 39-1/2 [1003] 44-1/2 [1130] 51 [1295] 59 [1499]
BC--1.0 03-01-1 Belt Drive Blower Coil Unit, Basic Unit Discharge ARGT. 1 4. See page 1 for filter rack details. 5. Base rail is optional on he base unit. See page 13. Base rails must be used with mixing
More informationVAHU Vertical Air Handling Unit
500 to 5,400 CFM @ up to 6.00" TSP 2" double wall construction, perforated or solid lined 18 gauge G90 galvanized steel cabinet 4 standard cabinet sizes available Internally isolated direct drive plug
More informationThe Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat
Producing Quality Heating & Cooling Equipment For Over 50 Years CEA SERIES CEILING EPOSED HORIZONTAL FAN COIL UNITS The Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat
More informationMAH. Modular Air Handling Unit
MA Modular Air andling Unit 500 to 11,000 CFM @ up to 6.00 TSP 2 and 4 double wall construction, perforated or solid lined 18 gauge G0 galvanized steel cabinet 26 standard cabinet sizes available Internally
More informationMODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING
MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING MADE IN USA SIZES FROM 600 TO 9,000 All Technical Specifications are Subject to Change without
More informationHORIZONTAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT
HORIZONTAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT MADE IN USA SIZES FROM 600 TO 9,000 All Technical Specifications are Subject to Change
More informationMODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING
MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING SIZES FROM 600 TO 9,000 All Technical Specifications are Subject to Change without Notice.
More informationMODELS CP65 THROUGH CP1030
CURBPAK AIR HANDLING UNITS INSTALLATION, OPERATION & MAINTENANCE New Release Form 100.10-NOM2 (301) MODELS CP65 THROUGH CP1030 00466vip ROOF MOUNTED SINGLE ZONE IMPORTANT! READ BEFORE PROCEEDING! GENERAL
More informationIssue 4 (Record Only) Job #: Innovent Submittal Date: October 30, 2012 Project: Location: Columbus, OH Innovent Job #: Submittal Issue: 4 (Record Only) Engineer: Contractor: Tag Innovent Model # AHU-BG-01
More informationSBH / SBV Sales Guide BLOWER-COILS HORIZONTAL AND VERTICAL
SO TOUGH, WE GUARANTEE IT. SBH / SBV Sales Guide BLOWER-COILS HORIZONTAL AND VERTICAL SBH SBV www.superiorrex.com SO TOUGH, WE GUARANTEE IT! www.superiorrex.com SBH / SBV Series: CONSTRUCTION FEATURES
More informationWE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL
PREPARED FOR: DATE: JOB NAME: WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL EQUIPMENT DETAILS ITEM TAG DESCRIPTION MODEL NUMBER 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 EQUIPMENT
More informationROOF TOP SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING
ROOF TOP SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING MADE IN USA SIZES FROM 600 TO 9,000 All Technical Specifications are Subject to Change without
More informationRERV & RERVX RERVLP. Rotary Energy Recovery Ventilators. Low Profile Indoor Rotary Energy Recovery Ventilators
Version: Dec. 01, 2004 RERV & RERVX Rotary Energy Recovery Ventilators Indoor and Outdoor Installations 250 20,000 CFM Capacities RERVLP Low Profile Indoor Rotary Energy Recovery Ventilators Ideal for
More informationFS Fan-Coil Units Hi-Rise, Vertical
FS Fan-Coil Units Hi-Rise, Vertical FSC Concealed Dimensional Data 4-PIPE 2-PIPE TOP VIEWS Page Trims Short (5/8") Here! SIDE VIEW FRONT VIEW Dimensions Unit Size A B Single/Double Supply C D E 03 & 04
More informationProduct Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm
Product Data 42BH System Fan Coil 800 to 4000 Cfm Satisfy All Your Design Requirements with Carrier s Versatile 42BH Fan Coil Unit A selection of 6 sizes covers capacities from 800 to 4000 cfm Choice of
More informationTSS Single-Duct VAV Terminals
TSS Single-Duct VAV Terminals Model TSS construction features Standard Construction Mechanical-lock construction ensures lowest possible casing leakage Roll-formed inlet collar with integral stiffening
More informationBAC, BAF, BAH Central Station Air Handlers
PRODUCT DATA & INSTALLATION Bulletin B80-BA-PDI-5 Part # 1097717 PRODUCT SUPPORT web: b-rp.ca/bah email: ahu@b-rp.ca call: 1-844-893-3222 x527 scan: BAC, BAF, BAH Central Station Air Handlers Indoor and
More informationInstallation, Start-Up and Service Instructions
39M Central Station Air-Handling Units Sizes 03-30 Installation, Start-Up and Service Instructions CONTENTS Page INTRODUCTION.................................. 1 SAFETY CONSIDERATIONS......................
More informationMulti-Path RTU-TYPE 9 (RTU-1) CES-MPU-025-RE-VAV9
ALDI # CITY, STATE SUPERMARKET MultiPath RTUTYPE 9 (RTU1) CESMPU025REVAV9 Date: December 1, 2014 2013 Consolidated Energy Solutions, Inc. UNIT FEATURES CES TYPE VAV9 Unit features include: 25 ton MultiPath
More informationUniversity of Delaware
SECTION 23 36 00 _ SUMMARY PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Constant/Variable volume supply terminal units. 2. Fan powered terminal units. 3. Exhaust valves B. Related Sections: Section
More informationDIRECT-DRIVE BLOWER FAN COIL AIR CONDITIONER ENGINEERING GUIDE
DIRECT-DRIVE BLOWER FAN COIL AIR CONDITIONER ENGINEERING GUIDE Model: YSHW-DD 00784VIP Introduction YORK DIRECT DRIVE FAN COIL UNITS The YORK Fan Coil Unit is designed for many exposed and concealed applications.
More informationFN Fan-Coil Units High-Performance, Horizontal
FN Fan-Coil Units High-Performance, Horizontal Model FNX Exposed-Cabinet Dimensional Data Notes: 1. All dimensions are in inches [mm] and are +/- 1/8" [3 mm]. Metric values are soft conversions. 2. See
More informationSDL Single-Duct, Low-Height, VAV Terminals
SDL -Duct, Low-Height, VAV Terminals SDL -Duct, VAV Terminals: Fit more comfort in less space Owners SDL terminals offer the typical benefits provided by single-duct units, while performing at extremely
More informationELTAFANTECH Air Handling Unit 700 up to 42,000 CFM
an ELTA GROUP company ELTAFANTECH 700 up to 42,000 CFM INNOVATIVE Design & Performance INTRODUCTION There are 24 standard sizes of optimally engineered s to handle air volumes from 700 CFM to 42,000CFM.
More informationPERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINTS
50FN-1SB 50FNX,FNY078,088,104 SINGLE-PACKAGE COOLING UNITS CONSTANT/VARIABLE AIR VOLUME PRODUCT INTEGRATED CONTROLS CARRIER COMFORT NETWORK COMPATIBLE WITH INTEGRAL ECONOMIZER AND HIGH-CAPACITY MODULATING
More informationA. NU2035 HRV Specifications NU2035
A. NU2035 HRV Specifications NU2035 B. Available Options CUSTOMIZATION: This series of H/ERVs is highly customizable and purpose built for the project it was designed into. See the nomenclature details
More informationHorizontal and Vertical BELT DRIVE AIR HANDLING UNITS
Horizontal and Vertical BELT DRIVE AIR HANDLING UNITS TABLE OF CONTENTS H & V Features and Benefits...4 Coil and Filter Data, Static Pressure Data...7 Electric Resistance Heat Section...8 Coil Information
More informationMcQuay MDM Air Handling Unit CMDM
McQuay MDM Air Handling Unit CMDM - 2004 Contents Page Nomenclature System... 1 Features... 2 Performance Tables... 4 Outlines and Dimensions... 15 Section Weights... 23 Installation... 25 Operation...
More informationProduct Data. 39T Central Station Air-Handling Units. Features/Benefits. Nominal 3,500 to 46,000 Cfm
Product Data 39T Central Station Air-Handling Units Nominal 3,500 to 46,000 Cfm Features/Benefits Flanged and gasketed modular components units are available as a single assembly up to 40 ft long, or shipped
More information"SPOAU" DEDICATED 100% OUTSIDE AIR UNITS Self Contained Single Package or Split System Units
"SPOAU" DEDICATED 100% OUTSIDE AIR UNITS Self Contained Single Package or Split System Units Spinnaker Industries Inc. Model Series SPOAU 100% Outdoor Air Systems shall be factory assembled, wired and
More informationSubmittal 30 [762] 36 [914] 40 [1016] 50 [1270] 60 [1524] 70 [1778]
FCU-THBP-1.0 08-22-18 THBP Horizontal Low Profile Plenum Return Top View (Drain Pan Omitted) Bottom View Front View Left hand unit shown. All dimensions are inches [millimeters]. Side View Unit Size A
More informationLaboratory Room Single Duct Supply Air Terminal
Technical Specification Sheet Document No. 149-319A June 24th, 2010 Laboratory Room Single Duct Supply Air Terminal Features Figure 1. Laboratory Room Single Duct Supply Air Terminal. The APOGEE Automation
More informationAIR HANDLING UNIT. MODEL: PM0809 to PM CFM to CFM
AIR HANDLING UNIT MODEL: PM0809 to PM2738 700CFM to 41000 CFM POWER METAL TECHNOLOGIES (M) SDN BHD Lot 37830, Jalan Bukit Naga, Kampung Bukit Naga, Section 32, 40460 Shah Alam, Selangor Darul Ehsan. Tel:
More informationVERTICAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT
VERTICAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT SIZES FROM 600 TO 4,000 All Technical Specifications are Subject to Change without Notice.
More informationXeteX, Inc. All Rights Reserved.
Model XC Indoor or outdoor mounted, simple, in-case aluminum flat plate exchanger with options for frost control. Ideal for inline installations: in duct-work systems, in built-up units, or in modular
More informationProduct Data. Features/Benefits. 39NX Central Station Air-Handling Units. Nominal 2,000 to 55,000 Cfm
Product Data 39NX Central Station Air-Handling Units Nominal 2,000 to 55,000 Cfm Features/Benefits Sloped, double-wall coil condensate drain pan complies with ASHRAE Standard 62 Double-wall casings solid,
More informationRAV Sales Guide FAN COIL UNITS HI-RISE, VERTICAL
RAV Sales Guide FAN COIL UNITS HI-RISE, VERTICAL RAVS RARM RARS RAVE RAVM RAVL RARP RISER www.superiorrex.com RAV Series: VERTICAL HI-RISE CONCEALED SO TOUGH, WE GUARANTEE IT! www.superiorrex.com Model
More informationFOR USE IN SOLUTION AIR HANDLING UNITS
AMS-60 AIRFLOW MONITORING DEVICE APPLICATION GUIDE Supersedes: NOTHING Form 102.20-AG1 (303) FOR USE IN SOLUTION AIR HANDLING UNITS GENERAL The YORK AMS-60 is an airflow monitoring device which combines
More informationThis series of H/ERVs is highly customizable and purpose built for the project it was designed into. See the nomenclature details that follow.
NU1030 HRV Specifications Available Options CUSTOMIZATION: This series of H/ERVs is highly customizable and purpose built for the project it was designed into. See the nomenclature details that follow.
More informationNomenclature. Contents. Air Handling Unit SR AH 250 LP HS
SARAN Mf g. Group 1 Contents Features...... 2-4 Selection Procedures... 5-7 Capacity Ratings (Chilled Water, D.X Coil, Hot Water, Steam Ratings)... 8-15 Correction Factor Tables... 16-18 Dimensions (Horizontal
More informationSPECIFICATIONS AND DESIGN ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE. EDITION 11
AIR HANDLING UNIT (DOUBLE SKIN) MODEL: DS-CW/DX-AHU-H (Chilled Water or Direct Expansion) CAPACITY: 3.3 to 125 Nominal Tons 39,000 to 1,500,000 BtuH 11.4 to 439.5 KW 1,300 to 50,000 CFM Benefits Horizontal
More informationThis series of H/ERVs is highly customizable and purpose built for the project it was designed into. See the nomenclature details that follow.
NU2540 ERV Specifications Available Options CUSTOMIZATION: This series of H/ERVs is highly customizable and purpose built for the project it was designed into. See the nomenclature details that follow.
More informationVIFB Coil Technical Guide
TGVIFB-5 VIFB Coil Technical Guide VERTICAL TUBE INTEGRAL FACE AND BY-PASS HEATING COILS FOR AIR PREHEATING Since 1875, the L.J. Wing Company has been a leader in providing innovative solutions for difficult
More informationSPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES EER 8.5 ARI RATINGS* K2ES120A25 10 NOMINAL TONS WITH TWO 5 TON CIRCUITS
550.13-TG11Y (0500) SPLIT-SYSTEM EVAPORATOR BLOWER K2ES120A25 10 NOMINAL TONS WITH TWO 5 TON CIRCUITS EER 8.5 DESCRIPTION This completely assembled dual circuit evaporator blower includes a well-insulated
More informationTGIF-3. Indirect Fired Heating Systems. Technical Guide for: IF Indoor Installations. IFW Outdoor Installations. Applied Air. Keeps You.
TGIF-3 Indirect Fired Heating Systems Technical Guide for: IF Indoor Installations IFW Outdoor Installations Applied Air Keeps You Warm Indirect Fired Heating Systems Technical Guide In the business of
More information500-YVI PARALLEL FAN-POWERED AIR TERMINAL UNIT FORM EG3 (404)
500-YVI PARALLEL FAN-POWERED AIR TERMINAL UNIT Table of Contents Introduction...3 500-YVI Features...4-5 Dimensional Data...6-7 ARI Rating Points...8 Statement of Standard Test Conformity...8 Motor Amperage
More informationMcQuay. Central Station Air Handlers Low Pressure. LHD, LYF, LSL, LML, LWL Vintage C. LML, LSB Vintage E. Last Manufactured: 1999
Replacement Parts List No. 055222600 Revision F 11/2011 McQuay Central Station Air Handlers Low Pressure LHD, LYF, LSL, LML, LWL 103-228 Vintage C LML, LSB 106-111 Vintage E Last Manufactured: 1999 To
More informationTYPICAL SPECIFICATION: Critical Process Roof Top Unit 7/14/15
UNIT CONSTRUCTION: Casing: A. 2.5 NTM (No Thru Metal Casing) 1. Base frame fabrication utilizes a single frame construction for supporting the casing and internal component. 2. The casing walls and roof
More informationTVS/R FAN COIL UNITS HI-RISE, VERTICAL
TVS/R FAN COIL UNITS HI-RISE, VERTICAL TVRM TVRP Riser TVRS TVSE TVSM TVSR TVSS Redefine your comfort zone. www.titus-hvac.com Redefine your comfort zone www.titus-hvac.com Model TVS/R: CONCEALED, HI-RISE
More informationTECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:
036-21323-001-B-0202 GENERAL SPECIFICATIONS OUTDOOR UNIT: Two independent refrigerant circuits Inherently protected fan motors Two independent scroll compressors V-Coil Design Exterior service port connections
More informationPERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS
50FP-1SB 50FP034, 038, 044, 048, 054, 064, 074 SINGLE-PACKAGE COOLING UNITS CONSTANT/VARIABLE VOLUME PRODUCT INTEGRATED CONTROLS CARRIER COMFORT NETWORK COMPATIBLE FACTORY-INSTALLED OPTIONAL ELECTRIC HEAT
More informationWarm. DFC Direct Fired Gas Heating System. Applied Air. Keeps You. Technical Guide for: Outdoor Mounted Units To 100,000 CFM And 14M BTUH
TGDFC-6 DFC Direct Fired Gas Heating System Technical Guide for: Outdoor Mounted Units To 0,000 CFM And 14M BTUH Applied Air Keeps You Warm Featuring the Patented AdaptAire controlled Circulation System
More informationDirect Gas-Fired Heating
Direct Gas-Fired Heating Model DG 800 to 15,000 cfm Up to 1,600,000 BTU/hr Optional Evaporative Cooling January 2005 PRODUCT FEATURES Model DG Direct Gas-Fired Make-Up Air Unit The Greenheck model DG is
More informationSkyline Outdoor Air Handler
Catalog 570-1 Skyline Outdoor Air Handler Sizes 003 to 090 MEA 342-99-E Contents Nomenclature and Certification..................... 1 ARI certification...................................... 1 IBC certification
More informationA Division of Nailor International Inc. ECONOMY AIR HANDLERS
A Division of Nailor International Inc. MODEL : ECONOMY AIR HANDLERS Thermal Model Standard Specification MODEL 800-4000 CFM AIR HANDLERS Description Model air handlers are designed for efficient and economical
More informationWAC Air Curtains Technical Guide
TGWAC-2 WAC Air Curtains Technical Guide FOR WIND STOPPING, INSECT CONTROL, AND ENVIRONMENTAL SEPARATION IN COMMERCIAL AND INDUSTRIAL APPLICATIONS TABLE OF CONTENTS Introduction......................................................................2
More informationUNIVERSITY OF NORTH FLORIDA Arena HVAC Replacement SECTION MODULAR INDOOR CENTRAL-STATION AIR-HANDLING UNITS
SECTION 23 73 13 MODULAR INDOOR CENTRAL-STATION AIR-HANDLING UNITS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions.
More informationAir Handling Unit Fan Selection Guide
KEES Air Handling Unit Fan Selection Guide This document applies to models: DFG Direct Fired Gas Heater IFG Indirect Fired Gas Heater MUA Tempered Air NTS Non-Tempered Supply Table of Contents: Page 2-4
More informationVariable Air Volume (VAV) Pressure Independent Control
VAV Terminal Units Asli Variable Air Volume (Vav) Terminal Units are volume flow rate controller for supply air on variable air volume system. These units are designed to control the airflow rate of conditioned
More informationBulletin BCF 103 DESIGN 10A BACKWARD INCLINED WHEELS
Bulletin BCF 10 DESIGN 10A BACKWARD INCLINED WHEELS Proven Reliability in Industrial Environments and Corrosive Atmospheres Design 10A s with Backward Inclined Wheels Chicago s Design 10A is a rugged multi-purpose
More informationElectric Coil [Make-Up Air / Displacement Ventilation / Space Heating] System
V-Series (rev. 08/17/10) Electric Coil [Make-Up Air / Displacement Ventilation / Space Heating] System Note: Optional items and/or items requiring a choice, are shown between brackets and/or parentheses
More informationSubmittal. Front View Side View
RBHO Horizontal Low Profile Concealed Free Return Submittal FCU-RBHO-1.0 07-25-18 Top View (Drain Pan Omitted) Bottom View Front View Side View Left hand unit shown. All dimensions are inches [millimeters].
More informationComfortable. Cooling/Heating Comfort Systems. Applied Air. Keeps You. Technical Guide for: IFL TGIFL-4
TGIFL-4 Cooling/Heating Comfort Systems Technical Guide for: IFL High Efficiency, High Turndown, High Filtration Comfort Systems Applied Air Keeps You Comfortable Cooling/Heating Comfort Systems Technical
More informationDual Duct Variable Air Volume Terminal (Model TDS)
Product Bulletin Issue Date June 21st, 2005 Dual Duct Variable Air Volume Terminal (Model TDS) Model TDS terminals provide Variable Air Volume (VAV) control beyond the typical dual duct box. They are specifically
More informationMODEL IFG INDIRECT FIRED MAKE-UP AIR HEATER
L (Housing Arr. H) 4" 6" A=Blower B=Filter C=Intake Downturn Plenum W Intake damper (Optional) H Birdscreen " Curb Cap D Electrical connection H Housing V-bank filters intake hood Gas connection E Lifting
More informationInstallation, Start-Up and Service Instructions
39NC Curb-Mounted Central Station Air-Handling Units Installation, Start-Up and Service Instructions This air-handling equipment is designed to provide safe and reliable service when installed correctly
More informationcatalog SDL Single-Duct, Low-Height, VAV Terminals
catalog SDL Single-Duct, Low-Height, VAV Terminals Catalog: ET130.13-EG2 (708) TABLE OF CONTENTS Single-Duct, Low-Height VAV Terminals Features and Benefits....................... 2 Controls..................................
More information50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS
R FORM NO: MS0305F Products That Perform...By People Who Care AIR - COOLED SPLIT SYSTEM AIR CONDITIONERS WITH SCROLL COMPRESSORS 50 Hz COOLING CAPACITY- 60 MBH TO 1360 MBH ACCS SERIES HEB-D, EB-D SERIES
More informationSECTION AIR TERMINAL UNITS
SECTION 23 36 00 AIR TERMINAL UNITS PART 1 - GENERAL 1.1 SUMMARY A. Section includes constant volume terminal units, variable volume terminal units, dual duct terminal units, fan powered terminal units,
More informationProduct Data. Features/Benefits. 35K Bypass Terminal. 110 to 4400 cfm
Product Data 35K Bypass Terminal 110 to 4400 cfm Carrier s 35K Series bypass terminals offer: 20-gage, galvanized steel casing construction 1/2-in. thick, dual density fiberglass insulation meeting NFPA
More informationFAN POWERED TERMINAL UNITS
Benefits: Fan powered terminals are typically used for heating and cooling of perimeter zones. Operating cost savings can be achieved through the use of waste heat recovery from the ceiling plenum and
More informationFAN POWERED TERMINAL UNITS
Benefits: Fan powered terminals are typically used for heating and cooling of perimeter zones. Operating cost savings can be achieved through the use of waste heat recovery from the ceiling plenum and
More informationcatalog SDL Single-Duct, Low-Height, VAV Terminals
catalog SDL Single-Duct, Low-Height, VAV Terminals TABLE OF CONTENTS Features and Benefits.... 2 Controls.... 3 Construction Features... 4 Standard and Optional Features.... 5 Dimensional and Weight Data....
More information42C/D SERIES Ducted Chilled Water Fan Coil Unit With District Cooling Application
42C/D SERIES Ducted Chilled Water Fan Coil Unit With District Cooling Application MAXIMIZING PERFORMANCE, ENERGY SAVINGS & COMFORT MODEL NUMBER NOMENCLATURE 4 2 C E T 0 0 3 4 7 0 1 2 5 42 series CISB Code
More informationSi Series Model CE Residential Geothermal Heat Pump
Si Series Model CE Engineering Submittal Sheet Overview and Certifications Standard Features, Factory Installed Options, and Field Installed Accessories Standard Features CE Model 025-071 5 Models: 025,
More informationRoof Upblast and Sidewall Exhaust
XRUB, XRUD, XSEB, XSED, and XRUBS models are listed for electrical (UL/C-UL US 705) File no. E40001 and for grease removal (UL/C-UL US 762) File no. MH11745. Accurex, LLC certifies model XRUB, XRUD, XSEB,
More information500-YCI SERIES FAN-POWERED AIR TERMINAL UNIT FORM EG2 (404)
500-YCI SERIES FAN-POWERED AIR TERMINAL UNIT Table of Contents General Information...3 500-YCI Features...4-5 Dimensional Data...6-7 ARI Rating Points...8 Statement of Standard Test Conformity...8 Motor
More informationIAQ. Model AVC. SINGLE DUCT VAV Model AVC
NON FAN POWERED UNITS SINGLE DUCT VAV Model AVC Model AVC The Carnes Model AVC is available as a basic control unit with open end discharge, with an optional multi-discharge adapter module, or sound attenuator
More informationRECORD SUBMITTAL COVER SHEET
RECORD SUBMITTAL COVER SHEET PROJECT TITLE: AXCELLERATE PHARMA EQUIPMENT DESCRIPTION: CARRIER AERO AIR-HANDLING UNIT AHU-1 OWNER: AXCELLERATE PHARMA MECHANICAL ENGINEER: ARDEN DATE: JUNE 27, 2014 SUBMITTED
More informationINSTALLATION & OPERATION MANUAL. Fan Powered Terminals VAV TERMINALS. Redefine your comfort zone.
INSTALLATION & OPERATION MANUAL Fan Powered Terminals VAV TERMINALS IOM FAN POWERED TERMINALS Receiving Inspection After unpacking the terminal, check it for shipping damage. If any shipping damage is
More informationB. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410.
PART 1 - GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
More informationCentrifugal Exhaust Fans Series C. Roof Upblast and Sidewall
Centrifugal Exhaust s Series C Roof Upblast and Sidewall April 28 Series C - Spun Aluminum Roof Upblast and Sidewall Centrifugal Exhaust s When you buy a Greenheck Series C model, you receive a fan with
More informationCentrifugal Filtered Supply Roof Blowers
CFS Centrifugal Filtered Supply Roof Blowers Page Introduction...................................... 2 Specifications and Dimension Data................... 3 Typical Installation................................
More informationClimas y Proyectos Leyco, S.A. de C.V.
GENERAL DESCRIPTION : FURNISH AND INSTALL MULTI COMPONENT ROOF MOUNTED LEYCO, MODEL CAH CUSTOM AIR HANDLER MADE SELF-CONTAINED, WEATHER RESISTANT, AIR HANDLING UNITS PER MODEL NUMBER, AND PERFORMANCE DATA
More informationSECTION CONTROL DAMPERS
SECTION 23 09 13.43 - CONTROL DAMPERS PART I - GENERAL 1.1 SECTION INCLUDES A. Airfoil Dampers, Heavy Duty Galvanized Steel B. Thermally Insulated Dampers, Heavy Duty Galvanized Steel C. Airfoil Dampers,
More informationAIR ZONE INTERNATIONAL MIXED-FLOW AIR COLUMN UNIT
ZONE INTERNATIONAL MIXED- COLUMN UNIT 5220 TED ST. HOUSTON, TEXAS 77040 (713) 460-4040 FAX (713) 460-4050 WWW.ZONEINC.COM ZONE INTERNATIONAL MIXED- COLUMN UNIT T DUCT COLLAR INLET (A x B) PRIMARY RETURN
More informationCentrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved
Centrifugal Roof Supply Fans Models and Forward Curved April 2008 Centrifugal Filtered Roof Supply Fan When you buy a Greenheck model or, you receive a fan with the industry s best performance and durability
More informationVertical Hi-Rise Fan Coil Unit (Model FS)
Technical Bulletin Issue Date March 1, 2005 Vertical Hi-Rise Fan Coil Unit (Model FS) Model FS Vertical Hi-Rise fan coil units are designed to maximize flexibility of selection and installation. The units
More informationSUBMITTAL. Palm Beach Gardens Fire Station. Fausto Frias
SUBMITTAL Project Palm Beach Gardens Fire Station Date February 5, 2018 Fausto Frias Prepared For TLC Attention- Steve Job Name Palm Beach Gardens Fire Station Mark for AHU-1 Date February 5, 2018 Unit
More informationSECTION AXIAL HVAC FANS
SECTION 233413 - AXIAL HVAC FANS 1. PART 1 GENERAL 1.1. RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationDaikin McQuay. Large Capacity Fan Coil Belt Drive. HCBB, HHBB Design 1. Replacement Parts List No Revision E 03/2018
Replacement s List No. 700024000 Revision E 03/2018 Daikin McQuay Large Capacity Fan Coil Belt Drive HCBB, HHBB 08-30 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit
More informationAir Handling Unit Construction Checklist
Air Handling Unit Construction Checklist Project: Date: AHU Tag: Location: Submittal / Approvals Submittal. The above equipment and systems integral to them are complete and ready for functional testing.
More informationRBV Sales Guide FAN COIL UNITS FLOOR-MOUNTED, VERTICAL
RBV Sales Guide FAN COIL UNITS FLOOR-MOUNTED, VERTICAL RBVS RBVR RBVC www.superiorrex.com RBV Series: LOW POWER CONSUMPTION, ACCESSIBLE AND FLEXIBLE Owners Owners can choose between a standard or elevated
More informationProduct Data. 35J Single-Duct Retrofit Terminal Units for Variable Air Volume Systems. 40 to 3700 cfm
Product Data 35J Single-Duct Retrofit Terminal Units for Variable Air Volume Systems 40 to 3700 cfm The 35J retrofit terminal units offer: Unit casing of 22-gage galvanized steel construction (optional
More informationFiltered Kitchen Supply Packaged Ventilator
Filtered Kitchen Supply Packaged Ventilator Page Introduction........................................... 2 Information............................................ 3 Specifications and Dimension Data KD................................................
More informationMcQuay. Central Station Air Handler. LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL Vintage D. LML, LSB, MMM, MSB Vintage E
Replacement Parts List No. 046902100 Revision D 01/2015 McQuay Central Station Air Handler LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL 137-172 Vintage D LML, LSB, MMM, MSB 137-172 Vintage E Last Manufactured:
More informationDaikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision B 03/2016
Replacement s List 70002400 Revision B 03/206 Daikin McQuay Large Capacity Fan Coil Direct Drive HCDB, HHDB 06-20 Design To find your Daikin Applied parts distributor, call -800-377-2787 or visit www.daikinapplied.com
More informationRoof Upblast and Sidewall Exhaust
XRUB, XRUD, XSEB, XSED, and XRUBS models are listed for electrical (UL/C-UL US 0) File no. E000 and for grease removal (UL/C-UL US ) File no. MH. Accurex, LLC certifies model XRUB, XRUD, XSEB, XSED, and
More information