NewAge Epoxy Catalog. Inert, Strong, Durable Soil Pipe. For the life of the building. Toll Free:

Size: px
Start display at page:

Download "NewAge Epoxy Catalog. Inert, Strong, Durable Soil Pipe. For the life of the building. Toll Free:"

Transcription

1 NewAge poxy Catalog Inert, Strong, urable Soil Pipe or the life of the building. Toll ree: West Airport lvd. Suite 100 Sugar Land, TX Phone: ax: mail:

2 NewAge poxy Corrosion Protection in WV APPLICATIONS Medical acilities Hospitals, Trauma Centers, Laboratories, ialysis Clinics, esearch acilities nhanced WV Kitchens, ars, rink Machines, Grease Interceptors, Waterless Urinals, High fficiency, Casinos estructive lements & nvironments Maritime, Corrosive Soils, ainwater, oiler ooms, etc. Sustainable uildings with waste volumes flowing from 0% to 0% less High Occupancy Structures High ises, Malls, Shopping Centers, Schools, Colleges, Universities, Arenas, Stadiums, Theatres, Convention Centers, Office Complexes Assisted Living Centers Convalesent Homes, MOs COST A cost effective alternative to plastic, acid waste, glass pipe, duriron, & stainless steel. We offer a solution to existing pipe materials, sizes, & specifications. POXY COATING TSTING 1 - Salt Spray - Chemical - High temperature waste testing - Temperature cycling testing INSTALLATION Standard installation practices Apply epoxy paint to any exposed surface POUCTS No Hub from 1-1/ to 1 Couplings SPCIICATION & STANAS ASTM - A888 CISPI 01 ASTM 177 & 10 - egular & xtra H Couplings N 877 Coating Specification & Testing

3 WLCOM TO TH NWAG QUALITY YOU CAN COUNT ON TAL O CONTNTS SUMITTALS: POXY NH-NO HU Page# UPC LISTING: POXY NH - NO HU (818) Page# 1 CATALOG Page# Please contact us for specific documentation requests for any Products. 10 West Airport lvd., Suite100 Sugar Land, TX P Toll ree:

4 New Age poxy: Corrosion Protection in WV, a leading provider of Cast Iron Soil Pipe, is launching NewAge poxy for additional corrosion protection in the WV application. This product is ideal for situations that call for enhanced protection of the WV system like Hospitals, Medical Treatment acilities, Soda Machines, Kitchens, ars, Maritime Saltwater Applications, Water-less Urinals, and Low low / High fficiency Urinals and Toilets. xcessive Corrosion on the cast iron system leads to the system failing, therefore requiring the system to be re-piped or replaced. As re-pipe s are a huge burden for a building owner and its tenants, deterioration on the WV system is something that contractors, engineers and owners want to avoid. To minimize this corrosion issue, engineers have since updated their WV specification with different piping systems including plastic, dual containment, acid waste, dura-iron, and glass pipe to resist excessive corrosion. NewAge has received feedback from contractors and engineers on the limitations of the bituminous asphalt coating in severe environments. Our research and testing has proven that NewAge poxy will resist chemicals, acids, salt water, and many other forms of excessive corrosion and will protect the cast iron system for the life of the building. Please contact your local NewAge epresentative to get more information and to set up a meeting to discuss NewAge poxy. NewAge is here to serve your cast iron system needs. Thank You for your interest. 10 West Airport lvd., Suite100 Sugar Land, TX P Toll ree:

5 NWAG POXY SUMITTAL Manufacturer s egistered Trademark Country of Origin ate of Manufacture T NWAG POXY PIP X 10 ASTM A888 UPC XXX XXX XXX J 10 T HuLeSS PIPe ITTINGS NO-HU PIP 10 T Hubless 1/ end W/ Heel NOM J T SIZ INSI IAMT OUTSI IAMT Certified to conform to CISPI 01 Standard Specification for Hubless Cast Iron Soil Pipe and ittings. oundries are Nom. CrATe/ LIST ITem WT SIze ox PrICe Code (LS.) NewAge Soil Pipe Products No-Hub (IN.) Cast Iron Soil Pipe and ittings certified QTY. by -- (each) UPC NH $8.0 IPC NH $.0 Two part epoxy spray on coating shall have NH00. mil minimum 11.0exterior thickness and $9.80 mil minimum interior thickness for superior CrATe/ adhesion, chemical LIST (acidic and alkali) resistance, durability, fire resistance, heat resistance and superior flow characteristics. ox Two part epoxy PrICe is tested to be non reactive from ph 1pH. The epoxy coating will not sag, cold flow or become soft. The two part epoxy QTY. resists caviation (each) and cathodic disbondment. 18 $.0 NOM. 1 1/ 1.0 ± ± opening extended ± ± LIST Nom..9 ± 0.09CrATe/. LIST Quarter end ± ITem WT ox PrICe SIze ox PrICe Code (LS.).9 ± ± QTY. (each) (IN.) QTY. (each) 0 $11.0 x NH ± $9.10 ± $1.0.9 ± ± $ ± ± $ ± ± $ ± ± $.0 Wye ± ± $17.80 Certified to conform to ASTM A 888, most recent revision, Standard Specification for Hubless Cast Iron Soil Pipe and ittings. CrATe/ Hubless double 1/ end - 90 MIN CrATe/ ox QTY. LIST PrICe (each) 1 $.0 8 $7.90 Hubless Tapped 1/ end - 90 Nom. SIze (IN.) ITem Code WT (LS.) CrATe/ ox QTY. LIST PrICe (each) P-Trap ouble Quater end1 1/ x 1 1/ w/1/ NH0 Primer Tap 1. San Cross $1.0 x 1 1/ NH $1.0 x NH $1.0 ouble Combination Wye & 1/8 end 10 West Airport lvd., Suite100 Sugar Land, TX P Toll ree:

6 NewAge poxy Specification Sanitary and Storm rain, Waste, and Vent Piping: I. General The epoxy coated cast iron soil pipe shall be installed above or below ground and is intended for WV systems in commercial buildings. II. Components a. poxy coated hubless cast iron soil pipe and fittings. b. Shielded PM xtra Heavy uty (XH) couplings for hubless cast iron soil pipe and fittings. III. Applicable Codes and Standards a. poxy coated hubless cast iron soil pipe and fittings shall conform to ASTM A-888, most current revision, through an accredited third party organization that complies with ISO/IC Guide requirements. b. All epoxy coated hubless cast iron soil pipe shall be hydro tested at psi. c. PM extra heavy duty couplings for hubless cast iron soil pipe and fittings shall conform to ASTM C10, excluding gasket material. d. Heavy duty shielded couplings shall be 01 stainless steel with /1 hex head screws and shall have a torque rating of 80 in-lb. Heavy uty shielded couplings shall have four bands for 1 ½ - diameter couplings and six bands for -1 diameter couplings. e. All couplings shall have a thylene-propylene-iene-monomer (PM) based interior rubber sleeve. IV. poxy Coating a. General: poxy coating on all hubless cast iron soil pipe and fittings shall be composed of two part epoxy resin with pigment and fillers. The epoxy shall have excellent resistance to water and alkali. The smooth surface shall result in a coefficient of friction of 10 Hazen-Williams or less. 10 West Airport lvd., Suite100 Sugar Land, TX P Toll ree:

7 b. Coating Parameters: escription Interior xterior Surface Preparation ust, dust, oil, grease and loosely adhering deposits shall be removed ry Thickness.7-.1 mil for pipe and fittings mil for pipes and.7-.1mil for fittings Color Yellow Ochre Green c. Coating Properties: escription Interior and xterior Counting Chemical esistance Shall be exposed to a ph solution for 0days at 7º and a 1 ph solution for 0days at 7º. Interior shall be rinsed to remove any chemical residue and immediately inspected for any wear, loss of epoxy material and leakage. Adhesion Interior Coating is Level 1 as per N ISO 09 and xterior Coating is Level as N ISO 09 Salt Spray esistance Shall be exposed to concentrated salt water solution for at least 0 hours then rinsed to remove any salt residue and immediately inspected for any chipping, flaking or blistering. Temperature Cycling esistance Shall have 100 cycles of flowing water from 0º to 0º, rinsed and cut lengthwise and immediately inspected for rust and blistering. 10 West Airport lvd., Suite100 Sugar Land, TX P Toll ree:

8 lame esistance Sample coating shall be subjected to a 0.77 TU/in event for two minutes with no flames being formed and no damage to the surface. Compatibility With Other Coatings poxy shall be compatible with paints normally used on metallic surfaces. Hot Water esistance poxy coated samples shall be immersed in a 0º water bath for hours and internal surface is immediately inspected for any blistering which shall not exceed dimension, class in accordance with ISO 8-. Combustibility and Use in eturn Air Plenum ASTM 8: Cast iron soil pipe is defined as non-combustible and is recommended for return air plenum installations. 10 West Airport lvd., Suite100 Sugar Land, TX P Toll ree:

9 Welcome the NewAge NewAge of Welcome to to the of Soil Soil Pipe Pipe NWAG XTA HAVY UTY COUPLINGS SUMITTAL Certifications & Standards Meets ASTM C 10 Meets ASTM C Meets CSA 0 Products are IAPMO and CSA Listed Material Specification Screw Type 0 AISI Stainless Steel /8 Shield Type 0 AISI Stainless steel, corrugated. Shield thickness 008 ands Type 0 AISI Stainless Steel Gasket Primary lastomeric Polymer is Neoprene to meet ASTM C Screw housing Type 0 AISI stainless steel Technical Specification The NewAge xtra Heavy (XH) uty Couplings compliment the NewAge Cast Iron Soil Pipe System. The NewAge XH Couplings are manufactured and tested to meet and exceed the ASTM C10 standard. The gasket is made from properly vulcanized virgin elastomeric compound, where the primary material is polychloroprene (neoprene). The gasket is a one piece design tested to meet the physical requirements of ASTM C. The corrugated shield is made from Type 0 stainless steel and provides a sturdy design which is to be installed with a pre-set torque wrench calibrated at 80 inch-pounds to accommodate the /8 hex head screws, four (1-1/ through ) and six ( through 1 ) respectively. The stainless steel bands are of / wide with 0 stainless steel screw housing provides sealing torque. The couplings are tested to ASTM C10 and are listed with IAPMO. /8 HX HA /8 HX HA 1 7/1 Typ. for all sizes Size Sizes through 1 L W Width No. of ands 11/ & 8 & & 1. Torque 80 in-lbs 80 in-lbs 80 in-lbs 80 in-lbs Sizes 1 1/ through 908 Westhollow Parkway Houston, TX 7708 P / Casting NewAge 10 West West Airport Airport lvd.,ivera Suite d. 10 lvd., Suite100 Sugar Land, TX Santa e Springs, CA Sugar Land, TX P Toll ree: ree: : P P Toll Mail: info@newagecasting.com Toll ree: Mail:info@newagecasting.com info@newagecasting.com -Mail: 7

10 Welcome to the NewAge of Soil Pipe NWAG PM XTA HAVY UTY COUPLINGS SUMITTAL Certifications & Standards Meets ASTM C 10 excluding gasket material Meets CSA 0 Products are IAPMO and CSA Listed Material Specification Screw Type 0 AISI Stainless Steel /8 Shield Type 0 AISI Stainless steel, corrugated. Shield thickness 008 ands Type 0 AISI Stainless Steel Gasket Primary lastomeric Polymer is PM Screw housing Type 0 AISI stainless steel Technical Specification The NewAge PM xtra Heavy (XH) uty Couplings compliment the NewAge poxy System. The NewAge PM XH Couplings are manufactured and tested to meet and exceed the ASTM C10 excluding the gasket material portion of the standard. The gasket is made from ethylene propylene diene monomer and is a gasket of one piece design tested to meet the physical requirements of ASTM C. The corrugated shield is made from Type 0 stainless steel and provides a sturdy design which is to be installed w/ a pre-set torque wrench calibrated at 80 inch-pounds to accommodate the /8 hex head screws, four (1-1/ through ) and six ( through 1 ) respectively.the stainless steel bands of / width with 0 stainless steel screw housing provides sealing torque. The couplings are tested to ASTM C10. /8 HX HA /8 HX HA 1 7/1 Typ. for all sizes Size Sizes through 1 L Width No. of ands 11/ &.0 8 & 10 1 & 1. W Torque 80 in-lbs 80 in-lbs 80 in-lbs 80 in-lbs Sizes 1 1/ through 10 West Airport lvd., Suite100 Sugar Land, TX P Toll ree:

11 TST POT Welcome to the NewAge of Soil Pipe Ph: ax Web: ast Philadelphia Street Ontario, California USA eport Number: eport Issued: ecember 7, 01 Project No.: 107 Client: Manufacturer: Source of Samples: NW AG CASTING COMPANY 0 Westhollow Parkway, Suite #108 Houston, TX 7708 Quwo Hengtong Casting Co., Ltd (Trademark SH ) The sample was sent by the manufacturer and received by IAPMO &T Lab in good condition on October 0, 01. ate of Testing: November 19, 01 to ecember 7, 01 Sample escription: Hubless Cast Iron Pipes Sizes: 1-1/, *,,,,, 8, 10, 1 and 1. * Sample evaluated Scope of Testing: The purpose of the testing was to determine if the sample evaluated of the cast iron pipes meet the applicable requirements of ASTM A , entitled "Standard Specification for Hubless Cast Iron Soil Pipe and ittings for Sanitary and Storm rain, Waste and Vent Piping Applications". CONCLUSION: The sample evaluated of the hubless cast iron soil pipe, as shown above, from NW AG CASTING COMPANY COMPLI with the applicable requirements of ASTM A y my signature below we certify that all the testing and sample preparation for this report was performed under continuous, direct supervision of IAPMO &T Lab unless stated otherwise valuated y, Ken Wijaya, Sr. Laboratory irector 10 West Airport lvd., Suite100 Sugar Land, TX P Toll ree: This report may not be copied, except in its entirety, without the written permission of IAPMO &T Lab

12 Primary Standard: ASTM A888-11, Section evaluated: Welcome to the NewAge of Soil Pipe 9. Coating Note: The Hubless Cast Iron Pipes are currently UPC Listed, file no. 818 for complying with ASTM A On the sample evaluated, the manufacturer has changed the coating with poxy Anticorrosive Coating (Yellow at the inside of the pipe and ed at the outside of the pipe). Therefore, only the above mentioned section of the standard was conducted. Test esults: All tests and evaluations were conducted per the written procedures specified in the standard. ASTM A Coating COMPLI 9.1 The pipe evaluated was uniformly coated with a material suitable for the purpose, that is adherent, not brittle, and without a tendency to scale. The coating contained no asbestos (refer to material safety data sheets and statement from manufacturer). Material safety data sheets were furnished by the coating manufacturer and will be available when requested. The coatings were evenly and smoothly applied to all surfaces. 9. The pipes were coated with epoxy coating containing no lead (refer to material safety data sheets and statement from manufacturer). 9. The manufacturer committed to annually prepare and submit samples to a qualified laboratory for test in accordance with Practice 1. efer to statement from manufacturer. 9. The manufacturer committed to prepare and submit samples when changing sources of supply or the coating manufacturer changes formulations for the coating. efer to statement from manufacturer. 9. The manufacturer committed to maintain all records for a period of seven years. efer to statement from manufacturer. 9. Copies of the coating test will be furnished when requested. efer to statement from manufacturer. Photo of sample evaluated eport No West Airport lvd., Suite100 Sugar Land, TX P Toll ree:

13 IAPMO esearch and Testing, Inc. is a product certification body which tests and inspects samples taken from the supplier's stock or from the market or a combination of both to verify compliance to the requirements of applicable codes and standards. This activity is coupled with periodic surveillance of the supplier's factory and warehouses as well as the assessment of the supplier's Quality Assurance System. This listing is subject to the conditions set forth in the characteristics below and is not to be construed as any recommendation, assurance or guarantee by IAPMO esearch and Testing, Inc. of the product acceptance by Authorities Having Jurisdiction. The most updated information on this Certificate of Listing is available online at pld.iapmo.org ffective ate: September 01 Void After: September 01 Product: Cast Iron Soil Pipe and ittings (Hubless) ile No. 818 Issued To: New Age Casting Company 10 West Airort oulevard Suite #100 Sugar Land, TX 7778 Identification: ach length of pipe and each fitting shall be plainly marked with the country of origin, the manufacturer's name or the manufacturer's registered trademark by which the manufacturer can be readily identified after installation and any appropriate collective mark (optional). The marking shall be adequate identification of the manufacturer of the pipe and fittings if it readily identifies the manufacturer to the end user of the product. Markings shall be cast on fittings. Pipe markings: The pipe shall be marked continuously on the barrel with a minimum of 0.7 inch (19mm) lettering starting within inches of each end of the pipe. ach pipe shall be marked with the date of manufacture. The marking shall be stenciled on the pipe or otherwise applied so as to be clear and legible. itting markings: The marking shall be cast with raised letters that are not to be located within the "W" dimension. Cast markings shall be raised from the wall of the fitting unless otherwise noted. Listed products shall bear the UPC certification mark. Characteristics: Installed fittings and pipe must be IAPMO &T listed and installed in accordance with the requirements of the latest edition of the Uniform 10 West Airport lvd., Suite100 Sugar Land, TX P Toll ree: This listing period is based upon the last date of the month indicated on the ffective ate and Void After ate shown above. Any change in material, manufacturing process, marking or design without having first obtained the approval of the Product Certification Committee, or any evidence of non-compliance with applicable codes and standards or of inferior workmanship, may be deemed sufficient cause for revocation of this listing. Production of or reference to this form for advertising purposes may be made only by specific written permission of IAPMO esearch and Testing, Inc. Any alteration of this certificate could be grounds for revocation of the listing.

14 Page Void After: September 01 Product: Cast Iron Soil Pipe and ittings (Hubless) ile No. 818 Issued To: New Age Casting Company Plumbing Code Products listed on this certificate have been tested by an IAPMO &T recognized laboratory. This recognition has been granted based upon the laboratory's compliance to the applicable requirements of ISO/IC 170. Products are in compliance with the following code(s): Uniform Plumbing Code (UPC ) International Plumbing Code (IPC ) Products are in compliance with the following standard(s): ASTM A888-01a (excluding Annex A1) 10 West Airport lvd., Suite100 Sugar Land, TX P Toll ree:

15 Page Void After: September 01 Product: Cast Iron Soil Pipe and ittings (Hubless) ile No. 818 Issued To: New Age Casting Company MOLS: NO-HU CAST ION PIP: Model No. Size 1 1-1/" 18 " 10 " 1 " 1 " 18 " 170 8" " 17 1" 17 1" NO-HU ITTINGS: Short Sweep (MS) Long Sweep Model No. Size Model No. Size " 9 1-1/" " 9 " 8 " 9 " 70 " 98 " 7 " 7 8" 7 10" 1/ end W/" Heel Opening 7 1" 77 1" Model No. Size 7 " x " 80 " x " 8 " x " 1/ end educing Model No. Size 18 " x " 1/1 end San Tee (TY) Model No. Size Model No. Size 7 1-1/" /" 78 " 808 " x 1-1/" 80 " 810 " 8 " 81 " x 1-1/" 8 " 81 " x " 8 " 81 " 10 West Airport lvd., Suite100 Sugar Land, TX P Toll ree:

16 Page Void After: September 01 Product: Cast Iron Soil Pipe and ittings (Hubless) ile No. 818 Issued To: New Age Casting Company 88 8" 818 " x " 18 1" 80 " x " 19 1" 8 " 8 " x " 8 " x " 1/ end 88 " x " 80 " Model No. Size 8 " x " /" 8 " x " 190 " 8 " x " 19 " 8 " 19 " 88 " x " 19 " 80 8" 198 " 8 8" x " 00 8" 8 8" x " 8 8" x " 88 8" x " ouble 1/ end Model No. Size Long 1/ end 0 " (vent only) 0 " (vent only) Model No. Size 0 " (vent only) " x 18" Tapped 1/ end 1/ end Model No. Size Model No. Size 1-1/" x 1-1/" " 8 " x 1-1/" 8 " 0 " x " 0 " 1/ end 1/8 end Model No. Size Model No. Size 70 " 0 1-1/" 7 " 0 " 7 " 08 " 10 " 1 " San Cross 1 " 1 8" Model No. Size 17 10" /" (vent only) 18 " (vent only) 18 " (vent only) San Tap Cross 18 " x " (vent only) 18 " (vent only) Model No. Size 10 West Airport lvd., Suite100 Sugar Land, TX P Toll ree:

17 Page Void After: September 01 Product: Cast Iron Soil Pipe and ittings (Hubless) ile No. 818 Issued To: New Age Casting Company 188 " x " (vent only) /" x 1-1/" (vent only) 180 " x " (vent only) 01 " x 1-1/" (vent only) 187 " (vent only) 01 " x 1-1/" (vent only) 18 " x " (vent only) 018 " x " (vent only) 187 8" x " (vent only) 0 " x 1-1/" (vent only) 0 " x " (vent only) Test Tee San Tap Tee (Tap TY) Model No. Size 0 " Model No. Size 08 " /" x 1-1/" 00 " /" x 1-1/" 0 " 11 " 0 " 11 " x 1-1/" 0 8" 11 " x 1-1/" 08 10" 1 " 10 " x 1-1/" 1 " x " Iron ody Cleanout-Tapped 1 " x 1-1/" 18 " x " Model No. Size 870 " x " Wye Combination Wye and 1/8 end Model No. Size Model No. Size /" /" 11 " 198 " 11 " x " 19 " x 1-1/" 118 " 1700 " x " 10 " x " 170 " 1 " x " 170 " x " 1 " 170 " x " 1 " 1708 " 1 " x " 171 " 18 " x " 1710 " x " 10 " x " 171 " x " 1 " 171 " x " 1 " x " 1718 " x " 1 " x " 170 " x " 18 " x " 17 " x " 10 " x " 17 " x " 1 8" 17 " 1 8" x " 17 8" 1 8" x " 178 8" x " 18 8" x " 170 8" x " 10 8" x " 17 8" x " 1 8" x " 10 West Airport lvd., Suite100 Sugar Land, TX P Toll ree:

18 Page Void After: September 01 Product: Cast Iron Soil Pipe and ittings (Hubless) ile No. 818 Issued To: New Age Casting Company 11 10" 17 10" x " lind Plug 19 10" x " 10 10" x 8" Model No. Size 1 1" /" 1 1" 8 " 8 " 8 " Upright Wye 88 " 90 " Model No. Size 9 8" 1 " 9 10" 18 " x " 9 1" 10 " 9 1" 1 " x " 1 " x " Short educer Combination Wye and 1/8 end, ouble Model No. Size Model No. Size 18 " x 1-1/" 180 " 10 " x " 180 " 1 " x " 180 " x " 1 " x " 181 " 1 " x " 1808 " x " 18 " x " 10 " x " 1 " x " Closet end educing 1 " x " 1 " x " Model No. Size 18 " x " 8 " x " x " x 1" 10 8" x " 80 " x " x " x 1" 1 8" x " 8 " x " x " x 1" 1 8" x " 8 " x " x 10" x 1" 1 8" x " 8 " x " x 1" x 1" 18 8" x " 17 10" x " 17 10" x " Closet end 17 10" x 8" 17 1" x " Model No. Size 177 1" x " 90 " x " x " x 1" 178 1" x 8" 7 " x 10" x 1" 179 1" x 10" 7 " x " x 10" x 1" 180 1" x " 181 1" x " 18 1" x 8" Closet lange iser 18 1" x 10" 10 West Airport lvd., Suite100 Sugar Land, TX P Toll ree:

19 Page 7 Void After: September 01 Product: Cast Iron Soil Pipe and ittings (Hubless) ile No. 818 Issued To: New Age Casting Company 18 1" x 1" Model No. Size 9 " x " x -1/" P-Trap igure ive Model No. Size 0 1-1/" Model No. Size 08 " 80 " 10 " 80 " x " x " x " 1 " 80 " 1 " Cleanout errule (I..C.O.) P-Trap with Primer Model No. Size Model No. Size 8 " x 1/" 80 " 8 " x 1/" 8 " 8 " Tapped Adaptors P-Trap with Tapped Inlet Model No. Size " x 1-1/" Model No. Size " x " 8 1-1/" x 1-1/" 8 " x 1-1/" 88 " x " Closet lange Model No. Size ouble Wye 9 " x " Model No. Size 18 " eep Seal P-Trap 1 " 10 " x " Model No. Size 18 " " 1 " x " " 1 " x " 7 " 1 " x " 1 " 17 8" x " 18 8" 10 West Airport lvd., Suite100 Sugar Land, TX P Toll ree:

20 Page 8 Void After: September 01 Product: Cast Iron Soil Pipe and ittings (Hubless) ile No. 818 Issued To: New Age Casting Company AITIONAL COMPANY INO: NPM NO-HU CAST ION PIP: Model No. Size 1 1-1/" 18 " 10 " 1 " 1 " 18 " 170 8" " 17 1" 17 1" NO-HU ITTINGS: Short Sweep (MS) Long Sweep Model No. Size Model No. Size " 9 1-1/" " 9 " 8 " 9 " 70 " 98 " 7 " 7 8" 7 10" 1/ end W/" Heel Opening 7 1" 77 1" Model No. Size 7 " x " 80 " x " 1/ end educing 8 " x " Model No. Size 18 " x " 1/1 end San Tee (TY) Model No. Size Model No. Size 7 1-1/" /" 78 " 808 " x 1-1/" 80 " 810 " 8 " 81 " x 1-1/" 8 " 81 " x " 8 " 81 " 10 West Airport lvd., Suite100 Sugar Land, TX P Toll ree:

21 Page 9 Void After: September 01 Product: Cast Iron Soil Pipe and ittings (Hubless) ile No. 818 Issued To: New Age Casting Company 88 8" 818 " x " 18 1" 80 " x " 19 1" 8 " 8 " x " 8 " x " 1/ end 88 " x " 80 " Model No. Size 8 " x " /" 8 " x " 190 " 8 " x " 19 " 8 " 19 " 88 " x " 19 " 80 8" 198 " 8 8" x " 00 8" 8 8" x " 8 8" x " 88 8" x " ouble 1/ end Model No. Size Long 1/ end 0 " (vent only) 0 " (vent only) Model No. Size 0 " (vent only) " x 18" Tapped 1/ end 1/ end Model No. Size Model No. Size 1-1/" x 1-1/" " 8 " x 1-1/" 8 " 0 " x " 0 " 1/ end 1/8 end Model No. Size Model No. Size 70 " 0 1-1/" 7 " 0 " 7 " 08 " 10 " 1 " San Cross 1 " 1 8" Model No. Size 17 10" /" (vent only) 18 " (vent only) 18 " (vent only) San Tap Cross 18 " x " (vent only) 18 " (vent only) Model No. Size 10 West Airport lvd., Suite100 Sugar Land, TX P Toll ree:

22 Page 10 Void After: September 01 Product: Cast Iron Soil Pipe and ittings (Hubless) ile No. 818 Issued To: New Age Casting Company 188 " x " (vent only) /" x 1-1/" (vent only) 180 " x " (vent only) 01 " x 1-1/" (vent only) 187 " (vent only) 01 " x 1-1/" (vent only) 18 " x " (vent only) 018 " x " (vent only) 187 8" x " (vent only) 0 " x 1-1/" (vent only) 0 " x " (vent only) Test Tee San Tap Tee (Tap TY) Model No. Size 0 " Model No. Size 08 " /" x 1-1/" 00 " /" x 1-1/" 0 " 11 " 0 " 11 " x 1-1/" 0 8" 11 " x 1-1/" 08 10" 1 " 10 " x 1-1/" 1 " x " Iron ody Cleanout-Tapped 1 " x 1-1/" 18 " x " Model No. Size 870 " x " Wye Combination Wye and 1/8 end Model No. Size Model No. Size /" /" 11 " 198 " 11 " x " 19 " x 1-1/" 118 " 1700 " x " 10 " x " 170 " 1 " x " 170 " x " 1 " 170 " x " 1 " 1708 " 1 " x " 171 " 18 " x " 1710 " x " 10 " x " 171 " x " 1 " 171 " x " 1 " x " 1718 " x " 1 " x " 170 " x " 18 " x " 17 " x " 10 " x " 17 " x " 1 8" 17 " 1 8" x " 17 8" 1 8" x " 178 8" x " 18 8" x " 170 8" x " 10 8" x " 17 8" x " 10 West Airport lvd., Suite100 Sugar Land, TX P Toll ree:

23 Page 11 Void After: September 01 Product: Cast Iron Soil Pipe and ittings (Hubless) ile No. 818 Issued To: New Age Casting Company 1 8" x " 11 10" 17 10" x " lind Plug 19 10" x " 10 10" x 8" Model No. Size 1 1" /" 1 1" 8 " 8 " 8 " Upright Wye 88 " 90 " Model No. Size 9 8" 1 " 9 10" 18 " x " 9 1" 10 " 9 1" 1 " x " 1 " x " Short educer Combination Wye and 1/8 end, ouble Model No. Size Model No. Size 18 " x 1-1/" 180 " 10 " x " 180 " 1 " x " 180 " x " 1 " x " 181 " 1 " x " 1808 " x " 18 " x " 10 " x " 1 " x " Closet end educing 1 " x " 1 " x " Model No. Size 18 " x " 8 " x " x " x 1" 10 8" x " 80 " x " x " x 1" 1 8" x " 8 " x " x " x 1" 1 8" x " 8 " x " x 10" x 1" 1 8" x " 8 " x " x 1" x 1" 18 8" x " 17 10" x " 17 10" x " Closet end 17 10" x 8" 17 1" x " Model No. Size 177 1" x " 90 " x " x " x 1" 178 1" x 8" 7 " x 10" x 1" 179 1" x 10" 7 " x " x 10" x 1" 180 1" x " 181 1" x " 18 1" x 8" Closet lange iser 18 1" x 10" 10 West Airport lvd., Suite100 Sugar Land, TX P Toll ree:

24 Page 1 Void After: September 01 Product: Cast Iron Soil Pipe and ittings (Hubless) ile No. 818 Issued To: New Age Casting Company 18 1" x 1" Model No. Size 9 " x " x -1/" P-Trap igure ive Model No. Size 0 1-1/" Model No. Size 08 " 80 " 10 " 80 " x " x " x " 1 " 80 " 1 " Cleanout errule (I..C.O.) P-Trap with Primer Model No. Size Model No. Size 8 " x 1/" 80 " 8 " x 1/" 8 " 8 " Tapped Adaptors P-Trap with Tapped Inlet Model No. Size " x 1-1/" Model No. Size " x " 8 1-1/" x 1-1/" 8 " x 1-1/" 88 " x " Closet lange Model No. Size ouble Wye 9 " x " Model No. Size 18 " eep Seal P-Trap 1 " 10 " x " Model No. Size 18 " " 1 " x " " 1 " x " 7 " 1 " x " 1 " 17 8" x " 18 8" Sioux Chief Manufacturing Company, Inc Closet lange Model No. Size 890-I x 10 West Airport lvd., Suite100 Sugar Land, TX P Toll ree:

25 NWAG POXY CATALOG Manufacture s egistered Trademark Country of Origin ate of Manufacture T NWAG POXY PIP X 10 ASTM A888 UPC XXX XXX XXX 10 T NO - HU PIP 10 OOT SIZ 1.0 J 1.90 NOM 0.1 T MIN WIGHT 11/ J W 90 o 1/ N SIZ 11/ 11/ 11/ 11/ 11/ 1/ 1/ / 1/ 1/ 1/ 7 8 1/ 81/ 1/ (A) 90 o () UCING 1/ N SIZ W x 11/ 1/ 1/ 11/8 x 11/ 1/ 11/8 W 90 o 10 West Airport lvd., Suite100 Sugar Land, TX P Toll ree:

26 90 o 1/ N WITH HL OPNING XTN SIZ x 11/ 101/ 1/ x 11/ 1/ 11 /8 OUL 1/ N PAT # SIZ 00 11/ 1/ 00 11/ 1/ 00 11/ 1/ / N WITH HL OPNING SIZ x 11/ 7/8 1/ x 11/ 1/ 1/ LONG 1/ N PAT # SIZ 0 x 18 11/ 18 1/ Tapped Inlet TAPP 1/ N SIZ x 11/ x Pitch 1/ Per oot 11/ 11/ 11/ x 11/ 11/ 11/ 11/ x 11/ 11/ 1/ 11/ 1/ 1/ 1/ 1/ 1/ 1/ 1/ TAP 11/ 90 o LONG SWP (1/ N) SIZ 11/ 11/ 11/ 11/ 11/ 91/ 91/ / 111/ 1 7/ 8 81/ 9 91/ West Airport lvd., Suite100 Sugar Land, TX P Toll ree:

27 90 o SHOT SWP (1/ N) SIZ 8 11/ 11/ 11/ 1/ 1/ 7 71/ 81/ 9 101/ 1/ 1/ / 11/ / 11/ 111/ 1/8 N SIZ 11/ 11/ /8 / 11/ / 11/ 1/ 11/ 1/8 7/8 1/ / 1/1 1/ / 9/ / 7 /1 91/ 1/ N SIZ 11/ 11/1 11/ 1/1 1/ 11/ 7/1 1/1 N SIZ 11/ 11/ 1/8 / 11/ 1/8 11/ 1/ 1/ 11/ /1 7/8 1/ 8 1/ / 10 West Airport lvd., Suite100 Sugar Land, TX P Toll ree:

28 Tapped Inley: Pitch 1/ Per oot SANITAY TAP T SIZ 11/x11/ 11/ 9/1 1/ 11/ x 11/ 11/ 1/ 9/1 11/1 1/ 11/ x 11/ 11/ 1/ 1/1 11/1 1/ 11/ x 11/ 11/ 1/ 1/1 11/1 1/ 11/ x 11/ / 1/1 /8 1/ x11/ 11/ 1/ /1 11/1 1/ 11/ x 11/ / 9/1 /8 1/ x x 11/ x * OUL WY TAP 1/ 11/1 11/ 11/ 7/8 /1 8 1/ 11/ 1/ 1/1 1/ 11/ 11/ / 1/1 /8 1/ 11/1 O O * G SIZ 1 1/ * 1 1/ /8 /8 G x 1 1/ 1 1/ /1 /8 1 1/ 1 1/ 1 1/ / 8 1/ x 1 1/ 1 1/ /8 1 x 1 1/ 1 1/ 1/ /1 x 1 1/ 1 1/ 1 1/ 7 1/1 9 1/ 9 1/ 11 /1 7/1 1 1/1 10 / 1 1/1 /1 8 x 1/ / 11 1/1 1 1/1 /1 8 1/ 1/ 1 /8 17 1/8 / SANITAY T SIZ x 11/ x 11/ x x x x x x x x x x 8 x 8 x 8 x 8 x 8 11/ 11/ 11/ 1/ 1/ 1/ / 11/ 11/ 1/ 1/ /8 / 11/ 11/ 1/ 1/ 7/8 11/ 11/ 1/ 1/ / 11/ 11/ 1/ 7/8 11/ 11/ 8 1/ 11/ 11/ 1/ 1/ 7/8 11/ 11/ 1/ 8 1/ 11/ 11/ 1/ 1/ 9 1/8 11/ 1/ 8 1/ 11/ 1/ 9 /1 1/ 11/ 10 1/ 1/ 1/ 11 7/1 1/ 11/ 1/ 8 /1 11/ 1/ 10 11/1 1/ / 1/ / 11/ 1/ 1/ 9 /1 1/ 1/ 11/ 7 1/ 10 /8 1/ 1/ 11/ 1/ 7 1/ 11 1/ 1/ / 1/ 1/ 7 1/ 8 1 1/ 1/ 1/ 8 1/ 8 1/ 1 1/ 10 West Airport lvd., Suite100 Sugar Land, TX P Toll ree:

29 * O H O G G WY SIZ 1 1/ 11/ * 11/ G 11/ 11/ /8 /8 x 11/ 11/ /1 /8 1 1/ 11/ 11/ / 8 1/ x x 11/ 11/ 11/ 11/ 1/ / /1 x 11/ 11/ 11/ 7 1/1 7 1/ 9 1/ 8 1/1 7/1 1/1 x 11/ /1 1 11/1 x 11/ 8 1/ 11 /1 7/1 91/ 1 /8 1/8 x 11/ 8 1/ 8 /1 1/ x x 11/ 11/ 8 / 9 1/ 9 / 11 /1 1 1/ 1 1/1 x 10 1/ 10 / 1 1/ 1 1/1 9/1 /1 8 x 1/ 1/ 9 /8 8 1/ 9/1 8 x 1/ 1/ 9 1/1 9 1/1 1/8 8 x 1/ 1/ 10 /8 11 7/1 1/1 8 x 1/ / 11 /8 1 1/1 1 /8 8 x 8 1/ 1/ / 1/ 11 1/1 1 /8 1 /1 17 1/8 /1 / 10 x 10 x 1/ 11 11/1 1 1/8 1 /8 1 7/1 / /1 10 x / 1 11/1 1/1 18 /8 1 1/ /8 1/ 1 1 1/ 1/ 1/ 1/ 19 / 1/ 1/ 0 / / UPIGHT WY SIZ 11/ 1/ 7 G H 8 1/ x 11/ 1/ 7 1 1/ 8 /1 11/ 1/ 8 /8 /1 8 7/1 x 11/ 1/ / x 11/ 1/ 8 /8 111/1 8 7/1 11/ 9 / 7/1 9 1/8 H G O O O 1/ 1/ OUL COMINATION WY AN 1/8 N SIZ G H 1 1/ /8 1/8 /8 /8 x 1 1/ 1/ / /8 1 1/ 1 1/ 7 / / 1/1 1/ x 1 1/ 1/ 7 1/ /8 1 1/ x 1 1/ 7 1/ 8 1/ 8 1 1/1 9/1 1/ 1 1/ 9 1/ / 7/1 1/1 O 10 West Airport lvd., Suite100 Sugar Land, TX P Toll ree:

30 COMINATION WY AN 1/8 N SIZ * G H 1 1/ 11/ 11/ / /8 / / x 11/ 11/ 11/ 7/8 1/8 11/ 11/ /8 1/8 /8 /8 x 11/ 11/ 1/ / /8 1 1/ x 11/ 11/ 11/ 11/ 7 /1 1/ 8 7 1/ 8 /8 1/ 1 1/1 1/ 1/ x 11/ 11/ 71/ 8 1/ /1 9/1 1/ 11/ 11/ 9 1/ / 7/1 1/1 x 11/ 1/1 7 / 8 1/1 1/1 x 11/ 7 / /1 1 11/1 1/1 1/ x 11/ 9 / 10 1/ 11 /1 7/1 7 /1 11 / 1 1/ 1 /8 1/8 8 /8 1/ x 11/ 8 1/ 8 /1 1/ 1/ x 11/ 7 1/1 9 1/ 9 / 1 1/ 9/1 1/ x 11/ 9 / /1 1 1/1 7 1/1 x 1 11/ / 9/1 9 1/8 1/ 8 x 1/ 11/ 1 /8 9 7/1 1 /8 11 /1 1 1/1 11 /1 /1 7/8 10 /1 8 9/1 8 x 1/ 10 1/1 1 1/1 11 /1 7/8 8 9/1 x 8 1/ 1/ 11/ 1 1 / 1 /8 1 9/1 1 1/1 1 1/1 1/ / 9 / 11 H G * O O G SANITAY TAP COSS SIZ TAP 11/x11/ 11/ 1/ 9/1 11/1 1/ 11/ x 11/ 11/ 1/ 1/1 11/1 1/ 11/ x 11/ 11/ 1/ 1/1 11/1 1/ 11/ x 11/ / 1/1 /8 1/ x 11/ 11/ 1/ /1 11/1 1/ 11/ x 11/ / 9/1 /8 1/ x 11/ 11/ 1/ 1/1 11/1 1/ 11/ 10 West Airport lvd., Suite100 Sugar Land, TX P Toll ree:

31 * SANITAY COSS SIZ 11/ 11/ 1/ 1/ 1/ / 11/ 1/ 1/ 7/8 x 11/ 1/ 7/8 11/ 8 x 11/ 1/ 1/ 7/8 x 11/ 1/ 8 11/ 1/ 1/ 91/8 x 1/ 101/1 8 x 1/ 7 71/ 101/1 111/ 7 1/ TST T SIZ 11/ /1 /8 11/ 7/8 11/1 7 / 11/ 7/1 8 7/8 / 1/ 11 1/ 1/ 1 1/ /8 1 1/ / 0 TAP / 1/ Tapped Inlet SHOT INCAS UC SIZ x 11/ x x x 11/ 11/ 11/ 11/ * 11/ 11/ 11/ 11/ /8 /8 /8 /8 x x 11/ 11/ x x x x x 8 x 11/ 11/ 11/ 11/ 11/ 1/ 1/ 8 x 8 x 8 x 8 x 10 x 11/ 11/ 11/ 1/ 1/ 1/ 10 x 10 x 8 1 x 1 x 1 x 8 1 x10 11/ 1/ 1/ 1/ 1/ 1/ 7 1/ 1/ 71/ 1 x 11/ 1/ 7 1 x 1 x 8 1 x 10 1 x 1 1/ 1/ 1/ 1/ 1/ 1/ / 7 / 10 West Airport lvd., Suite100 Sugar Land, TX P Toll ree:

32 LIN PLUG C SIZ 1 1/ 1 / 1 / 1 / 1 / 1 / 8 1/ / 1 1/ J K P-TAP SIZ A 1 1/ C 7 1/ J 1/ 1 1/ 9 1/ 1 1/ 10 1/ 1/ K 0 A 1/ 1/ C C A J K P SAL P-TAP SIZ A 1 1/ C 7 1/ J 7 1/ 1 1/ / 10 1/ 8 K 1/ TWO WAY AL CLANOUT SIZ x x A 1 9 C 7 1/ x x 19 1/ 9 1/ 9 1/8 x x 18 / 9 1/ 9 1/8 A Tapped Inlet Pitch 1/ Per oot Tapped Inlet Pitch 1/ Per oot IGU IV (COM) SIZ 1 1/ 1/ 8 x x x 1 1/ 8 7/8 9/1 9 1/ 1 1/ 8 7/8 9/1 10 1/8 x x x 1 1/ 10 1/ 7 / 11 1/ 1 1/ 10 1/ 7 / 1 IGU ON (TAP COSS) SIZ x 11/ 11/ C 1/8 TAP 7/8 /1 7 11/ 10 West Airport lvd., Suite100 Sugar Land, TX P Toll ree:

33 1/8 1/ Tapped Inlet C 1/ o AT 19 1/8 Tapped Inlet TAP AAPT/UL SIZ TAP x 1 1/ 1 1/ /1 1 1/ 1 1/ /8 CLOST LANGS SIZ x x 7 1/ 7 1/ x 7 1/ C 1/ 1/ 1/ C 1/ IP TAP M A K 1.1/ /8 A P - T W/ 1/ PIM TAP C SIZ A 1 1/ C 7 1/ J 1/ 1 1/ 9 1/ 1 1/ 10 1/ 1/ K 0 1/ 1/ 1/ M /8 CLANOUT UL (I..C.O.) SIZ A /1 /1 /8 /8 TAP 11/ 1/ /1 1/ 7/1 1/ /1 10 West Airport lvd., Suite100 Sugar Land, TX P Toll ree:

34 Size 1 1/ - Size -1 XTA HAVY UTY STAINLSS STL COUPLING SIZ 1 1/ ITM CO XHC10 XHC00 XHC00 XHC00 XHC00 XHC00 XHC800 XHC1000 XHC100 XHC100 # O ANS INSTALLATION P TOQU (in. lbs.) COUPLING PM XTA HAVY UTY STAINLSS STL COUPLING SIZ 1 1/ ITM CO XHC10 XHC00 XHC00 XHC00 XHC00 XHC00 XHC800 XHC1000 XHC100 XHC100 # O ANS INSTALLATION P TOQU (in. lbs.) COUPLING West Airport lvd., Suite100 Sugar Land, TX P Toll ree:

35 General Terms and Conditions GNAL These terms and conditions shall control with respect to any purchase order or sale of Sellers products. No waiver, alteration or modification of these terms and conditions whether on uyers purchase order or otherwise shall be valid unless the waiver, alteration, or modification is specifically accepted in writing and signed by an authorized representative of Seller. LIVY Seller will make any effort to complete delivery of products as indicated on Sellers acceptance of an order, but Seller assumes no responsibility or liability, and will accept no back charge, for loss or damage due to delay or inability to deliver caused by acts of God, war, labor difficulties, accident, delays of carriers, by contractors or suppliers, inability to obtain materials, shortages of fuel or energy, or any other causes of any kind whatsoever beyond the control of Seller. Seller may terminate any contract of sale of its products without liability of any nature, by written notice of uyer, in the event that the delay in delivery or performance resulting from any of the aforesaid causes shall continue for a period of sixty (0) days. Under no circumstances shall Seller be liable for any special or consequential damages or for loss, damage, or expense (whether or not based on negligence) directly or indirectly arising from delays or failure to give notice of delay. WAANTY Seller warrants for ten (10) years from the date of shipment Sellers manufactured products to the extent that Seller will replace those having defects in material or workmanship when used for the purpose and in the manner which Seller recommends. If Sellers examination shall disclose to its satisfaction that the product is defective, and an adjustment is required, the amount of such adjustment shall the not exceed the net sales price of the defective products only and no allowance will be made for labor or expense of repairing or replacing defective product or workmanship or damage resulting from the same. No adjustment shall be implemented unless product in question is returned to seller in its originally installed condition, still connected to other components of the joint. uyer must contact Seller as quickly as possible so Seller can assess product in its installed condition. No claims will be honored unless claim is made within forty five () days of the defect being found. Where engineering design or fabrication work is supplied, uyers acceptance of Sellers design or of delivery of work shall relieve Seller of all further obligation, other than expressed in Sellers product warranty. THIS IS SLLS SOL WAANTY. SLLS MAKS NO OTH WAANTY O ANY KIN, XPSS O IMPLI AN ALL IMPLI WAANTIS O MCHANTAILITY AN ITNSS O A PATICULA PUPOS WHICH XC SLLS AOSTAT OLIGATION A HY ISCLAIM Y SLL AN XCLU OM THIS WAANTY. Seller neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of its engineering designs or product. This warranty shall not apply to any products or parts of products which (a) have been repaired or altered outside of Sellers factory, in any manner; (b) have been subjected to misuse, negligence or accidents; (c) have been used in a manner contrary to Sellers instructions or recommendations. Seller shall not be responsible for design errors due to inaccurate or incomplete information supplied by uyer or its representatives. This warranty is non-transferable. LIAILITY Seller will not be liable for any loss, damage, cost of repairs, incidental or consequential damages of any kind, whether based upon warranty (except for the obligation accepted by Seller under warranty above), contract or negligence, arising in connection with the design, manufacture, sale, use or repair of the products or of the engineering designs supplied to uyer. TUNS Seller cannot accept return of any products unless its written permission has been first obtained, in which case same will be credited subject to the following: (a) All material returned must, on its arrival at Sellers plant, be found to be in first-class condition; if not, cost of putting in saleable condition will be deducted from credit memoranda; (b) A handling charge deduction of twenty five percent (%) will be made from all credit memoranda issued for material returned; (c) transportation charges, if nor prepaid will be deducted from credit memoranda. SHIPMNTS All products sent out will be carefully examined, counted, and packed. The cost of any special packing or special handling caused by uyers requirements or request shall be added to the amount of the order. No claim for shortages will be allowed unless made in writing within ten (10) days of receipt of a shipment. Claims for products damaged or lost in transit should be made on the carrier, as Sellers responsibility ceases, and title passes, on delivery to the carrier. POUCTS Orders covering special or non-standard products are not subject to cancellation except on such terms as Seller may specify on application. PICS Prices and designs are subject to change without notice. All prices are.o.. Point of Shipment, unless otherwise stated. TAXS The amount of any sales, excise or other taxes, if any, applicable to the products covered by this order, shall be added to the purchased price and shall not be paid by uyer unless buyer provides Seller with an exemption certificate acceptable to the taxing authorities. 10 West Airport lvd., Suite100 Sugar Land, TX P Toll ree:

36 NOTS 10 West Airport lvd., Suite100 Sugar Land, TX P Toll ree:

37 Welcome to the NewAge.

38 10 West Airport lvd. Suite 100 Sugar Land, TX Phone: ax: mail: Toll ree: Welcome to the NewAge.

PIPE FITTING ACCESSORIES EFFECTIVE FEBRUARY 5, 2018

PIPE FITTING ACCESSORIES EFFECTIVE FEBRUARY 5, 2018 CANADIAN IMPORT PRICE LIST PIPE FITTING EFFECTIVE FEBRUARY 5, 2018 version: EFFECTIVE: FEBRUARY 5, 2018 (SUPERSEDES ALL PREVIOUS PRICING) CORONA CALL CENTER (U.S.) Toll Free: (877) 701-7827 Fax: (951)

More information

PIPE FITTING ACCESSORIES EFFECTIVE JANUARY 14, 2019

PIPE FITTING ACCESSORIES EFFECTIVE JANUARY 14, 2019 IMPORT PRICE LIST PIPE FITTING EFFECTIVE JANUARY 14, 2019 version: IMP-ACC-UPL.19.01 EFFECTIVE: JANUARY 14, 2019 (SUPERSEDES ALL PREVIOUS PRICING) CORONA CALL CENTER (U.S.) Toll Free: (877) 701-7827 Fax:

More information

EVALUATION SUBJECT: CAST IRON SOIL PIPE AND FITTINGS

EVALUATION SUBJECT: CAST IRON SOIL PIPE AND FITTINGS ICC-ES Report PMG-1220 Reissued 11/2017 This report is subject to renewal 11/2018 EVALUATION SUBJECT: CAST IRON SOIL PIPE AND FITTINGS DIVISION: 22 00 00 PLUMBING SECTION: 22 13 16 SANITARY WASTE AND VENT

More information

STEEL PIPE NIPPLES - WELDED Price Sheet PNW-7.18 Effective: July 16, 2018 Cancels Price Sheet PNW-3.18 of March 5, 2018

STEEL PIPE NIPPLES - WELDED Price Sheet PNW-7.18 Effective: July 16, 2018 Cancels Price Sheet PNW-3.18 of March 5, 2018 STEEL PIPE NIPPLES - WELDED Price Sheet PNW-7.18 Effective: July 16, 2018 Cancels Price Sheet PNW-3.18 of March 5, 2018 FOR THE MOST CURRENT PRODUCT/PRICING INFORMATION ON ANVIL PRODUCTS, PLEASE VISIT

More information

Effective Date: January 2017 Void After: January Product: ABS-DWV Pipe and Fittings File No. 1909

Effective Date: January 2017 Void After: January Product: ABS-DWV Pipe and Fittings File No. 1909 IAPMO Research and Testing, Inc. is a product certification body which tests and inspects samples taken from the supplier's stock or from the market or a combination of both to verify compliance to the

More information

INTRODUCTION INSTALLATION

INTRODUCTION INSTALLATION INTRODUCTION INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS This instruction manual includes installation, operation and maintenance information for the figure G73 gear operator. The figure G73 is

More information

Effective Date: May 2018 Void After: May Product: Flexible Water Connectors File No. 5747

Effective Date: May 2018 Void After: May Product: Flexible Water Connectors File No. 5747 IAPMO Research and Testing, Inc. is a product certification body which tests and inspects samples taken from the supplier's stock or from the market or a combination of both to verify compliance to the

More information

GRINNELL Model B302 and Model BN302 Grooved End Butterfly Valves with Gear Operators or Lever-Lock Operators General Description

GRINNELL Model B302 and Model BN302 Grooved End Butterfly Valves with Gear Operators or Lever-Lock Operators General Description Technical Services -00- +-0--0 www.grinnell.com GRINNELL Model B0 and Model BN0 Grooved End Butterfly Valves with Gear Operators or Lever-Lock Operators General Description The GRINNELL Models B0 and BN0

More information

DOMESTIC FIRE PRODUCTS

DOMESTIC FIRE PRODUCTS DOMESTIC FIRE PRODUCTS Price Sheet GR.FP-8.16 Effective August 15, 2016 Cancels Price Sheet GR.FP-7.15 of July 6, 2015 FOR THE MOST CURRENT PRODUCT / PRICING INFORMATION ON ANVIL PRODUCTS, PLEASE VISIT

More information

Effective Date: March 2018 Void After: March 2019

Effective Date: March 2018 Void After: March 2019 IAPMO Research and Testing, Inc. is a product certification body which tests and inspects samples taken from the supplier's stock or from the market or a combination of both to verify compliance to the

More information

Kennedy Valve. A Division of McWane, Inc. AWWA PRODUCTS

Kennedy Valve. A Division of McWane, Inc. AWWA PRODUCTS Kennedy Valve A Division of McWane, Inc. AWWA PRODUCTS 1021 East Water Street Elmira, NY 14902 Phone: (607)734-2211 Fax: (607)734-3288 Fax: (800)952-4771 E-Mail: sales@kennedyvalve.com www.kennedyvalve.com

More information

Price List. Catalog Eleven. Rigging. Effective February 16, Specialties Inc. manufacturer of stage equipment

Price List. Catalog Eleven. Rigging. Effective February 16, Specialties Inc. manufacturer of stage equipment Price List Catalog Eleven Rigging Effective February 16, 2015 & manufacturer of stage equipment (626) 575-0776 14850 Don Julian Road, Suite B (800) 221-9995 City of Industry CA 91746 www.hhspecialties.com

More information

GWC Valve International

GWC Valve International GWC Valve International PROVEN TECHNOLOGY FOR INDIVIDUAL VALVE SOLUTIONS WORLDWIDE API 6D SWING CHECK VALVES Pressure Class: ASME 150-2500 Size Range: 2-36 CATALOG NUMBER SC-1001 G W C V A L V E I N T

More information

Effective Date: June Rev. 3/26/2018- Void After: June Product: Plumbing Fixture Fittings File No. 4617

Effective Date: June Rev. 3/26/2018- Void After: June Product: Plumbing Fixture Fittings File No. 4617 IAPMO Research and Testing, Inc. is a product certification body which tests and inspects samples taken from the supplier's stock or from the market or a combination of both to verify compliance to the

More information

FIGURE 310A & 311A 3-PIECE BALL VALVE

FIGURE 310A & 311A 3-PIECE BALL VALVE INTRODUCTION This instruction manual includes installation, operation and maintenance information for the figure 310A, 310ASW, 311A, and 311ASW 3-piece 1000CWP, threaded end (NPT) or socket weld end (SW)

More information

FIGURE 310AM, 310AMSW & 311AM 3-PIECE BALL VALVE

FIGURE 310AM, 310AMSW & 311AM 3-PIECE BALL VALVE INTRODUCTION This instruction manual includes installation, operation and maintenance information for the figure 310AM, 310AMSW, and 311AM 3-piece 1000CWP, threaded end (NPT) or socket weld end (SW) ball

More information

PNeumatic actuators catalog

PNeumatic actuators catalog PNEUMATIC ACTUATORS PNeumatic actuators catalog table of contents Page Design Features 1 Construction Characteristics 3 Components 4 Dimensions & Weights 5 Technical Data 9 Selection 19 Terms & Conditions

More information

DeZURIK 2-24 (50-600mm) KGN-RSB BI-DIRECTIONAL CAST STAINLESS STEEL KNIFE GATE VALVES

DeZURIK 2-24 (50-600mm) KGN-RSB BI-DIRECTIONAL CAST STAINLESS STEEL KNIFE GATE VALVES 2-24 (50-600mm) KGN-RSB BI-DIRECTIONAL CAST STAINLESS STEEL KNIFE GATE VALVES Instruction D11023 October 2016 Instructions These instructions provide information about KGN-RSB Knife Gate Valves. They are

More information

Grinnell Grooved Fire Protection Products Grooved Fittings

Grinnell Grooved Fire Protection Products Grooved Fittings Technical Services: Tel: (800) 38-932 / Fax: (800) 79-5500 www.tyco-fire.com Grinnell Grooved Fire Protection Products Grooved Fittings General Description LPCB Vd S The grooved fittings provide an economical

More information

California Lead Plumbing Law Devices and Components

California Lead Plumbing Law Devices and Components IAPMO Research and Testing, Inc. is a product certification body which tests and inspects samples taken from the supplier's stock or from the market or a combination of both to verify compliance to the

More information

Discount Codes 07 DWV-PVC through 8 22 HVAC DWV - PVC. PVC Drain - Waste Vent Fittings. Includes: DWV - PVC - through 8 HVAC.

Discount Codes 07 DWV-PVC through 8 22 HVAC DWV - PVC. PVC Drain - Waste Vent Fittings. Includes: DWV - PVC - through 8 HVAC. Discount Codes 07 DWV-PVC through 8 22 HVAC DWV - PVC PVC Drain - Waste Vent Fittings Includes: DWV - PVC - through 8 HVAC s Effective: March 14, 2011 1 H x FPT H x MPT SP x MPT SP x SJ w/plastic Nut &

More information

PIPE FITTING ACCESSORIES EFFECTIVE JANUARY 1, 2019

PIPE FITTING ACCESSORIES EFFECTIVE JANUARY 1, 2019 CANADIAN IMPORT PRICE LIST PIPE FITTING EFFECTIVE JANUARY 1, 2019 version: CAN-IMP-UPL.19.01 EFFECTIVE: JANUARY 1, 2019 (SUPERSEDES ALL PREVIOUS PRICING) CORONA CALL CENTER (U.S.) Toll Free: (877) 701-7827

More information

ZINC UTILITY FITTINGS

ZINC UTILITY FITTINGS IMPORT PRICE LIST UTILITY FITTINGS COATED - C153 DI COMPACT MJ FITTINGS (ANSI/AWWA C153/A21.53) COATED - C110 DI FULL BODY MJ FITTINGS (ANSI/AWWA C110/A21.10) COATED - C153 DI PUSH-ON FITTINGS (ANSI/AWWA

More information

Air Curtain. Installation, Operating and Maintenance Instructions

Air Curtain. Installation, Operating and Maintenance Instructions Installation, Operating and Maintenance Instructions Save this manual for future reference. Air Curtain Model Numbers: ES026, ES036, ES042, ES048, ES060, ES072 READ THIS OWNER S MANUAL CAREFULLY BEFORE

More information

Pressurized Pond Filter Up to 850 gallons

Pressurized Pond Filter Up to 850 gallons Pressurized Pond Filter Up to 850 gallons REMINER CALL 1-888-755-4497 EFORE RETURNING TO STORE. MOEL/MOELO #PZF850 Questions, problems, missing parts? efore returning to your retailer, call our customer

More information

Cardinal DETECTO. PORTABLE PLATFORM SCALES Digital Type Series 850F Owner s Manual

Cardinal DETECTO. PORTABLE PLATFORM SCALES Digital Type Series 850F Owner s Manual Cardinal DETECTO PORTABLE PLATFORM SCALES Digital Type Series 850F Owner s Manual CARDINAL SCALE MFG. CO. PO BOX 151, WEBB CITY, MO 64870 0066-M176-O1 Rev H 10/06 417-673-4631 www.cardinalscale.com Printed

More information

ZINC UTILITY FITTINGS

ZINC UTILITY FITTINGS DOMESTIC PRICE LIST UTILITY FITTINGS COATED - C153 DI COMPACT MJ FITTINGS (ANSI/AWWA C153/A21.53) COATED - C110 DI FLANGE FITTINGS (ANSI/AWWA C110/A21.10) NOTE: The zinc fittings provided by Star Pipe

More information

INTERNATIONAL MALLEABLE IRON PIPE FITTINGS & UNIONS

INTERNATIONAL MALLEABLE IRON PIPE FITTINGS & UNIONS INTERNATIONAL MALLEABLE IRON PIPE FITTINGS & UNIONS PRICE SCHEDULE #101016 EFFECTIVE: OCTOBER 1, 2016 MADE IN BRAZIL, UNLESS NOTED 117 Gulick Street, Blossburg, PA 16912 www.wardmfg.com (800) 248-1027

More information

SFI SPECIFICATION 28.1 EFFECTIVE: AUGUST 25, 2017 *

SFI SPECIFICATION 28.1 EFFECTIVE: AUGUST 25, 2017 * SFI SPECIFICATION 28.1 EFFECTIVE: AUGUST 25, 2017 * PRODUCT: Polymer (Foam-Filled) Fuel Cells 1.0 GENERAL INFORMATION 1.1 This SFI Specification establishes uniform test procedures and minimum standards

More information

DeZURIK KUL KNIFE GATE VALVES

DeZURIK KUL KNIFE GATE VALVES KUL KNIFE GATE VALVES Instruction D11025 September 2013 Instructions These instructions are intended for personnel who are responsible for the installation, operation and maintenance of your KUL knife

More information

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables PVI 1800/PVI 2500 WARRANTY MANUAL Residential/Commercial Grid-Tied Photovoltaic Inverter 2009, Solectria Renewables Subject to Change REV 10.09 1 Product Warranty & RMA Policy 1.1 Warranty Policy The Solectria

More information

Installation & Operating Instructions for Zone Valve Boxes & Ball Valves

Installation & Operating Instructions for Zone Valve Boxes & Ball Valves V Series Zone Valve Box EV Series Zone Valve Box Ball Valve Page 1 of 9 Introduction The Powerex ball valves and zone valve boxes are cleaned for use with oxygen. Each valve is tested for leakage in both

More information

SUBMITTAL STANDARD NO-HUB COUPLINGS

SUBMITTAL STANDARD NO-HUB COUPLINGS SUBMITTAL STANDARD Date Architect Project Contractor Engineer PROFLO patented No-Hub Couplings are engineered to connect no-hub cast iron pipe in applications replacing the lessefficient hub & spigot material.

More information

Model D Spray Gun. Parts Identification Manual 2943J-ID. "Success through Unity" June 17, 2003 Issue 2 GUSMER CORPORATION

Model D Spray Gun. Parts Identification Manual 2943J-ID. Success through Unity June 17, 2003 Issue 2 GUSMER CORPORATION "Success through Unity" Model D Spray Gun Parts Identification Manual 2943J-ID June 17, 2003 Issue 2 GUSMER CORPORATION A Subsidiary of Gusmer Machinery Group, Inc. One Gusmer Drive Lakewood, New Jersey,

More information

DESIGN FEATURES PRECISION CAST BODY, PLUG AND COVER

DESIGN FEATURES PRECISION CAST BODY, PLUG AND COVER DESIGN FEATURES PRECISION CAST BODY, PLUG AND COVER All FluoroSeal Lined Plug Valves major pressure-bearing components are produced by investment casting, ensuring tight tolerance control and superior

More information

PVI 60KW, PVI 82KW, PVI 95KW

PVI 60KW, PVI 82KW, PVI 95KW PVI 60KW PVI 82KW PVI 95KW WARRANTY MANUAL Commercial, Grid-Tied Photovoltaic Inverters 2008, Solectria Renewables LLC Subject to Change DOC-020099 rev 024 1 1 Product Warranty & RMA Policy Warranty Policy

More information

STAINLESS STEEL FORGED FITTINGS 3000lb 304/304L & 316/316L Forged Stainless Steel Fittings Product Specifications

STAINLESS STEEL FORGED FITTINGS 3000lb 304/304L & 316/316L Forged Stainless Steel Fittings Product Specifications STAINLESS STEEL FORGED FITTINGS 3000lb 304/304L & 316/316L Forged Stainless Steel Fittings Product Specifications Manufactured in ISO9000:2000 Facility Manufactured to ASTM/ASME A182/SA182 Items conform

More information

EVERCONNECT TM. Table of Contents. No-Hub Pipe. Flexible. 7 Couplings. Pipe Caps. Heavy Weight. Test Plugs. Couplings. Shielded Transition

EVERCONNECT TM. Table of Contents. No-Hub Pipe. Flexible. 7 Couplings. Pipe Caps. Heavy Weight. Test Plugs. Couplings. Shielded Transition Table of Contents No-Hub Pipe Couplings Heavy Weight Couplings Shielded Transition Couplings 3 4 4 Flexible Pipe Caps Test Plugs Drain/Trap & Tubular Connectors 7 7 8 EVERCONNECT TM Flexible & Reducing

More information

Effective Date: May Rev. 1/9/2018- Void After: May Product: Lead Free Plumbing Products File No. 6905

Effective Date: May Rev. 1/9/2018- Void After: May Product: Lead Free Plumbing Products File No. 6905 IAPMO Research and Testing, Inc. is a product certification body which tests and inspects samples taken from the supplier's stock or from the market or a combination of both to verify compliance to the

More information

September 2012 / M&H C502 / Model 129

September 2012 / M&H C502 / Model 129 GENERAL FEATURES / GENERAL SPEC M&H AWWA C502 FIRE HYDRANTS Model 129 Traffic Model 250 PSI Working Pressure 500 PSI Hydrostatic Test AWWA UL / FM Approved Type: Compression type, opening against line

More information

APCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES

APCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES APCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES Instruction D12043 June 2016 DeZURIK Instructions These instructions provide installation, operation and maintenance information for APCO CRF-100A Rubber

More information

VERTICAL AND HORIZONTAL SPLIT CASE FIRE PUMPS

VERTICAL AND HORIZONTAL SPLIT CASE FIRE PUMPS 480 MODELS VERTICAL AND HORIZONTAL SPLIT CASE FIRE PUMPS REPAIR PARTS INDEX NOTE! Read and understand the pump and driver instructions before attempting to install, disassemble or repair the pump. Part

More information

Proven technology for individual valve solutions worldwide. GWC Valve International

Proven technology for individual valve solutions worldwide. GWC Valve International Proven technology for individual valve solutions worldwide FORGED STEEL VALVES GATE, GLOBE & CHECK PRESSURE CLASS: ASME 150-2500 SIZE RANGE: 1/4-3 API STANDARD: 602 ASME B16.34 Catal og Nu mb er f SV-

More information

DRAIN WATER TEMPERING KIT

DRAIN WATER TEMPERING KIT INSTALLATION, OPERATION AND MAINTENANCE MANUAL FOR FOR USE WITH SH(X) GAS FIRED HUMIDIFIER OUTDOOR MODELS CANADIAN HEAD OFFICE AND FACTORY 1401 HASTINGS CRES. SE CALGARY, ALBERTA T2G 4C8 Ph: (403) 287

More information

City of Storm Lake Fire Department Heavy Rescue Specifications

City of Storm Lake Fire Department Heavy Rescue Specifications INTENT OF SPECIFICATIONS City of Storm Lake Fire Department Heavy Rescue Specifications It shall be the intent of these specifications to provide a complete apparatus equipped as hereinafter specified.

More information

INTERNATIONAL MALLEABLE IRON PIPE FITTINGS & UNIONS

INTERNATIONAL MALLEABLE IRON PIPE FITTINGS & UNIONS INTERNATIONAL MALLEABLE IRON PIPE FITTINGS & UNIONS PRICE SCHEDULE #100217 EFFECTIVE: FEBRUARY 6, 2017 REV. 1 MADE IN BRAZIL, UNLESS NOTED 117 Gulick Street, Blossburg, PA 16912 (800) 248-1027 Sheet #100217,

More information

FOG Hog Grease Interceptor System Installation & Service Manual FOR USE WITH FOGHog FH-20, FH0-35, FH-50, FH-75, and FH-100

FOG Hog Grease Interceptor System Installation & Service Manual FOR USE WITH FOGHog FH-20, FH0-35, FH-50, FH-75, and FH-100 FOG Hog Grease Interceptor System Installation & Service Manual FOR USE WITH FOGHog FH-20, FH0-35, FH-50, FH-75, and FH-100 FOG Hog Manual 2009 Bio-Microbics, Inc. Revised Decemberl 2009. FOG Hog is registered

More information

WARRANTY POLICY. Grid-Tied Photovoltaic Inverters. Revision D. 2014, Solectria Renewables, LLC DOCIN

WARRANTY POLICY. Grid-Tied Photovoltaic Inverters. Revision D. 2014, Solectria Renewables, LLC DOCIN WARRANTY POLICY Revision D 2014, Solectria Renewables, LLC DOCIN-070360 1 Product Warranty & RMA Policy 1. Warranty Policy Warranty Registration: It is important to have updated information about the inverter

More information

CAST PIPE FITTINGS COUPLINGS

CAST PIPE FITTINGS COUPLINGS CAST PIPE FITTINGS COUPLINGS 00% Recyclable Recycled Content Environment Friendly 00% RECYCLABLE FIRE RATED SMOKE RATED Index HUBLESS SOIL PIPE Page TOOLS 4 5-6 7 35 8 8 9 0 5,6,25 8 2,24,25 26 27,28

More information

430B SERIES HORIZONTAL SPLIT CASE PUMP

430B SERIES HORIZONTAL SPLIT CASE PUMP 430B SERIES TWO Stage - DIAGONALLY HORIZONTAL SPLIT CASE PUMP REPAIR PARTS INDEX NOTE! Read and understand the pump and motor instructions before attempting to install, disassemble or repair the pump.

More information

APCO ASR-400/450 SEWAGE AIR RELEASE VALVES

APCO ASR-400/450 SEWAGE AIR RELEASE VALVES APCO ASR-400/450 SEWAGE AIR RELEASE VALVES Instruction D12005 December 2012 Instructions These instructions provide installation, operation and maintenance information for the APCO ASR- 400/450 Sewage

More information

Container Fountain Kit with LED Light

Container Fountain Kit with LED Light Container Fountain Kit with LED Light REMINDER CALL 1-888-755-6750 BEFORE RETURNING TO STORE. PACKAGE CONTENTS Questions, problems, missing parts? Before returning to your retailer, call our customer service

More information

PRODUCT OVERVIEW. FluoroSeal lined butterfly valves offer increased value by incorporating advanced design features:

PRODUCT OVERVIEW. FluoroSeal lined butterfly valves offer increased value by incorporating advanced design features: PRODUCT OVERVIEW Due to its specially contoured disc profile, the FluoroSeal fully PFA-lined butterfly valve offers high flow rates with minimal pressure drop throughout the entire range of disc rotation.

More information

Installation Manual DIAPHRAGM WELL TANK

Installation Manual DIAPHRAGM WELL TANK Installation Manual DIAPHRAGM WELL TANK IN-LINE SERIES: 2-5 & 7 GALLON VERTICAL SERIES: 14-20-25-32-36-52-65-86-96-119 GALLON HORIZONTAL SERIES: 7-14 & 20 GALLON NO LEAD NO LEAD: The weighted average of

More information

GETZ EQUIPMENT INNOVATORS SYSTEM DUST 120V ECONOMY PART NUMBER: 4G59542 OPERATING AND INSTRUCTION MANUAL

GETZ EQUIPMENT INNOVATORS SYSTEM DUST 120V ECONOMY PART NUMBER: 4G59542 OPERATING AND INSTRUCTION MANUAL GETZ EQUIPMENT INNOVATORS SYSTEM DUST 120V ECONOMY PART NUMBER: 4G59542 OPERATING AND INSTRUCTION MANUAL 2320 Lakecrest Drive, Pekin IL 61554 PH. (888) 747-4389 Fax (309) 495-0625 Website: www.getzequipment.com

More information

Megohmmeter Test Probe

Megohmmeter Test Probe Megohmmeter Test Probe User Manual ENGLISH www.aemc.com CHAUVIN ARNOUX GROUP Copyright Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All rights reserved. No part of this documentation may be reproduced

More information

PIPE REPAIR PRODUCTS REPAIR CLAMPS

PIPE REPAIR PRODUCTS REPAIR CLAMPS PIPE REPAIR PRODUCTS REPAIR CLAMPS The Standard of Excellence in the Industry 1213 BADGER STREET YORKVILLE, ILLINOIS 60560 (630) 553-0840 (800) 426-4301 FAX (630) 553-0181 www.cascademfg.com 2007-2015

More information

Manufacturing Facility is ISO9001:2000. Welded Steel Pipe Conform to ASTM A53. Threads Conform to ASME B1.20.1

Manufacturing Facility is ISO9001:2000. Welded Steel Pipe Conform to ASTM A53. Threads Conform to ASME B1.20.1 STEEL NIPPLES S40 & S80 Steel Nipple Product Specifications Manufacturing Facility is ISO9001:2000 Welded Steel Pipe Conform to ASTM A53 Threads Conform to ASME B1.20.1 800-678-2544 800-678-0857 www.msi-products.com

More information

Pneumatic Cylinder 14 Bore X 21 Stroke Part No. P Replaces Part No. P

Pneumatic Cylinder 14 Bore X 21 Stroke Part No. P Replaces Part No. P Pneumatic Cylinder 14 Bore X 21 Stroke Part No. P -322908-00000 Replaces Part No. P-191067-00000 Service Information WARNING: INSTALLATION AND MOUNTING The user of these devices must conform to all applicable

More information

Single Post Caliper Brake VC500

Single Post Caliper Brake VC500 Single Post Caliper Brake VC500 1 In accordance with Nexen s established policy of constant product improvement, the specifications contained in this manual are subject to change without notice. Technical

More information

Manufactured in compliance with NSF/ANSI a

Manufactured in compliance with NSF/ANSI a IAPMO esearch and Testing, Inc. is a product certification body which tests and inspects samples taken from the supplier's stock or from the market or a combination of both to verify compliance to the

More information

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description Technical Services: Tel: () 31-931 / Fax: () 791-55 Model F thru F3 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description The Mulsifyre Nozzles are open (nonautomatic) nozzles and

More information

Excerpt from Chapter 3 of the City Code that address Fats, Oils and Grease (FOG) control program that was adopted by the City Council on May 9, 2016.

Excerpt from Chapter 3 of the City Code that address Fats, Oils and Grease (FOG) control program that was adopted by the City Council on May 9, 2016. Excerpt from Chapter 3 of the City Code that address Fats, Oils and Grease (FOG) control program that was adopted by the City Council on May 9, 2016. Subd. 11. Grease Interceptors. A. Grease interceptors

More information

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Chef Bases

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Chef Bases Blue Air Commercial Refrigeration Inc. Installation & Operation Manual Chef Bases Please read this manual completely before installing or operating this unit! BACB53 BACB71 BACB74 BACB83 BACB86 BACB96

More information

GORE TRAILER MANUFACTURING INCORPORATED 305 Gore Trailer Road Whiteville, North Carolina 28472

GORE TRAILER MANUFACTURING INCORPORATED 305 Gore Trailer Road Whiteville, North Carolina 28472 (Revised September, 2005) GORE TRAILER MANUFACTURING INCORPORATED 305 Gore Trailer Road Whiteville, North Carolina 28472 WARRANTY TEN YEAR WARRANTY Subject to the requirements, exclusions and limitations

More information

DWV - PVC. PVC Drain, Waste & Vent Fittings. Includes: DWV - PVC - through 8 HVAC. List Prices. Effective: February 15, 2016

DWV - PVC. PVC Drain, Waste & Vent Fittings. Includes: DWV - PVC - through 8 HVAC. List Prices. Effective: February 15, 2016 Discount Codes 07 DWV-PVC through 8 22 VAC DWV - PVC PVC Drain, Waste & Vent Fittings Includes: DWV - PVC - through 8 VAC s Effective: February 15, 2016 Revised 2/29/2016 x FPT x MPT SP x MPT SP x SJ w/plastic

More information

OPERATION MANUAL Variable Speed Pump Controller Dated: 06/04/2013 Pump Down Application. Document No.: LMSII_V100_OM Page 1 of 8 Model-V100 LMS II

OPERATION MANUAL Variable Speed Pump Controller Dated: 06/04/2013 Pump Down Application. Document No.: LMSII_V100_OM Page 1 of 8 Model-V100 LMS II Document No.: LMSII_V100_OM Page 1 of 8 LMS II Document No.: LMSII_V100_OM Page 2 of 8 1. Operation: When the wet well level rises above the on level set point, the lead pump will start after an adjustable

More information

Kitchen Tech Series Air Curtain

Kitchen Tech Series Air Curtain Installation, Operating, and Maintenance Instructions Save this manual for future reference. Kitchen Tech Series Air Curtain Model Numbers: KTECH026, KTECH036, KTECH042, KTECH048, KTECH060, KTECH072, KTECH084,

More information

HSIV PLOW OPERATOR S MANUAL

HSIV PLOW OPERATOR S MANUAL PLOW RWF INDUSTRIES 873 Devonshire Ave., Woodstock, Ontario N4S 8Z4 Tel: (519) 421-0036 Toll Free: 1-800-263-1060 Fax: (519) 421-0028 Email: parts@rwfbron.com JANUARY 2015 THE INFORMATION CONTAINED IN

More information

Reach ins, Freeezers & Refrigerators Installation & Operation Manual

Reach ins, Freeezers & Refrigerators Installation & Operation Manual Reach ins, Freeezers & Refrigerators Installation & Operation Manual BSR23 BSF23 BSR49 BSF49 BSR72 BSF72 IMPORTANT SAFETY INSTRUCTIONS (SAVE THESE INSTRUCTIONS) Visit us on the web at www.blueairinc.com

More information

Operating and Installation Instructions

Operating and Installation Instructions Model Number 20902 Fabricator's Power Module Kit - Aluminum Operating and Installation Instructions CAUTION! This product is to be installed only by persons knowledgeable in the repair and modification

More information

Pneumatic Cylinder 14 Bore X 22 Stroke Part No. R (Formerly P )

Pneumatic Cylinder 14 Bore X 22 Stroke Part No. R (Formerly P ) Pneumatic Cylinder 14 Bore X 22 Stroke Part No. R434001268 (Formerly P -193419-00003) Service Information INSTALLATION Before installing this cylinder, all air lines in the system should be blown clean

More information

2015 & 2018 Fender Brace Installation Instructions

2015 & 2018 Fender Brace Installation Instructions 2015 & 2018 Fender Brace Installation Instructions Thank you for your purchase of this Hotchkis Performance product. Your Fender Brace set was designed with the performance and durability you ve come to

More information

Installation Instructions Model: AB Single-lever Pull-down Spray Faucet

Installation Instructions Model: AB Single-lever Pull-down Spray Faucet Kitchen & Bath Products, Inc. www.dawnusa.net Installation Instructions Model: Single-lever Pull-down Spray Faucet TABLE OF CONTENTS Preparation 2 Parts & Tools Needed 2 Installation 3-5 Care and Cleaning

More information

User s Guide CDCE-90-X SERIES. Conductivity Sensors. Shop online at omega.com SM

User s Guide CDCE-90-X SERIES. Conductivity Sensors. Shop online at omega.com SM User s Guide Shop online at omega.com SM e-mail: info@omega.com For latest product manuals: www.omegamanual.info CDCE-90-X SERIES Conductivity Sensors omega.com info@omega.com U.S.A. Headquarters: Servicing

More information

6701 KNIFE GATE VALVES

6701 KNIFE GATE VALVES INTRODUCTION This instruction manual includes installation, operation and maintenance information for 2" through 30" stainless steel and stainless steel lined knife gate valves. This manual addresses hand-wheel

More information

PVC Gasketed Fittings for PVC IPS Pressure Pipe ENGINEERED FOR DURABILITY

PVC Gasketed Fittings for PVC IPS Pressure Pipe ENGINEERED FOR DURABILITY For the most up-to-date version of this price list, EFFECTIVE MARCH 4, 2019 ENGINEERED FOR DURABILITY HARRINGTON CORPORATION P.O. BOX 10335 LYNCHBURG, VIRGINIA 24506-0335 For the most up-to-date version

More information

Schedule 80 - CPVC Pressure Fittings

Schedule 80 - CPVC Pressure Fittings Discount Codes 03 Schedule 80 CPVC Schedule 80 - CPVC Pressure Fittings List Prices Effective: August 25, 2012 Revised September 2014 2 Schedule 80 - CPVC Products Catalog www.lascofittings.com Pricing

More information

Central Vacuum Valves, Fittings & Accessories. Product Catalog.

Central Vacuum Valves, Fittings & Accessories. Product Catalog. Product Catalog 2 With our extensive offering of central vacuum products, Vaculine has established itself as a product innovator in the central vacuum industry. As Vaculine continues to evolve and adapt

More information

Specification for Remanufacture Alstom Model 5 Switch Machine

Specification for Remanufacture Alstom Model 5 Switch Machine Alstom Model 5 Switch Machine This page is intentionally left blank for the purpose of double sided printing Alstom Model 5 Switch Machine - Page 2 of 9 - (262) 658-3590 TABLE OF CONTENTS 1 SCOPE AND INTENT.5

More information

DWV-PVC PVC DRAIN, WASTE & VENT FITTINGS PRODUCTS PRICE LIST INCLUDES HVAC PRODUCTS. 07 DWV- PVC through 8 22 HVAC

DWV-PVC PVC DRAIN, WASTE & VENT FITTINGS PRODUCTS PRICE LIST INCLUDES HVAC PRODUCTS. 07 DWV- PVC through 8 22 HVAC PRICE GROUP DESCRIPTION DISCOUNT MULTIPLIER 07 DWV- PVC through 8 22 VAC PRODUCTS PRICE LIST DWV-PVC PVC DRAIN, WASTE & VENT FITTINGS INCLUDES VAC PRODUCTS DWV-PVC EFFECTIVE SEPTEMBER 18, 2017 KEY:...ub

More information

PORTABLE PLATFORM SCALES Digital Type Series 850F Owner s Manual

PORTABLE PLATFORM SCALES Digital Type Series 850F Owner s Manual PORTABLE PLATFORM SCALES Digital Type Series 850F Owner s Manual Model 850F CARDINAL SCALE MFG. CO. 0066-M176-O1 Rev J 203 E. Daugherty, Webb City, MO 64870 USA 11/14 Ph: 417-673-4631 Fax: 417-673-5001

More information

900 SERIES SPLIT CASE FIRE PUMP REPAIR PARTS INDEX

900 SERIES SPLIT CASE FIRE PUMP REPAIR PARTS INDEX 900 SERIES SPLIT CASE FIRE PUMP REPAIR PARTS INDEX Read and understand the pump and motor instructions before attempting to install, disassemble or repair the pump. Part # AF-03-326 2015 Pentair Ltd. 01/30/15

More information

DeZURIK 2 20" BOS BUTTERFLY VALVES

DeZURIK 2 20 BOS BUTTERFLY VALVES 2 20" BOS BUTTERFLY VALVES Instruction D10459 October 2013 2-20 BOS Butterfly Valves Instructions These instructions provide information about BOS Butterfly Valves. They are for use by personnel who are

More information

Straight-Bore Clutch LSCC-32, 44, 54

Straight-Bore Clutch LSCC-32, 44, 54 Straight-Bore Clutch LSCC-32, 44, 54 1 In accordance with Nexen s established policy of constant product improvement, the specifications contained in this manual are subject to change without notice. Technical

More information

Flowmaster K67/K69 Series Sanitary Air-Actuated Valve OPERATION MAINTENANCE & PARTS LIST

Flowmaster K67/K69 Series Sanitary Air-Actuated Valve OPERATION MAINTENANCE & PARTS LIST Flowmaster K67/K69 Series Sanitary AirActuated Valve OPERATION MAINTENANCE & PARTS LIST GENERAL INSTRUCTIONS DISASSEMBLY AND REASSEMBLY This manual contains disassembly and reassembly instructions with

More information

Effective Date: not available -Rev. 10/4/2012- Void After: Product: Lead Free Plumbing Products File No. 6371

Effective Date: not available -Rev. 10/4/2012- Void After: Product: Lead Free Plumbing Products File No. 6371 IAPMO Research and Testing, Inc. is a product certification body which tests and inspects samples taken from the supplier's stock or from the market or a combination of both to verify compliance to the

More information

Schedule 80 - CPVC Pressure Fittings

Schedule 80 - CPVC Pressure Fittings Discount Codes 03 Schedule 80 CPVC Schedule 80 - CPVC Pressure Fittings List Prices L15-80C Effective: March 26, 2015 Revised 9.22.2016 2 Schedule 80 - CPVC Products Catalog www.lascofittings.com Pricing

More information

Umatilla Electric Cooperative Net Metering Rules

Umatilla Electric Cooperative Net Metering Rules Umatilla Electric Cooperative Net Metering Rules Version: July 2017 Umatilla Electric Cooperative NET METERING RULES Rule 0005 Scope and Applicability of Net Metering Facility Rules (1) Rule 0010 through

More information

CW Optimizer Capacity Hat Kit. 75/80 and 80/40 Thunderbolt Vertical Antennas. for the DXE-7580-THK

CW Optimizer Capacity Hat Kit. 75/80 and 80/40 Thunderbolt Vertical Antennas. for the DXE-7580-THK CW Optimizer Capacity Hat Kit for the 75/80 and 80/40 Thunderbolt Vertical Antennas DXE-7580-THK DXE-7580-THK-INS Revision 1a DX Engineering 2012 P.O. Box 1491 Akron, OH 44309-1491 USA Phone: (800) 777-0703

More information

Submersible Waterfall Pump 1200 Gallons Per Hour

Submersible Waterfall Pump 1200 Gallons Per Hour ITEM # LL1200 Submersible Waterfall Pump 1200 Gallons Per Hour REMINDER CALL 1-888-412-6001 EFORE RETURNING TO STORE. PACKAGE CONTENTS Questions, problems, missing parts? efore returning to your retailer,

More information

StormPro BA Series Sump Pump

StormPro BA Series Sump Pump Page 1 of 8 Marks & Meanings DANGER: Keep the pump equipment out of the reach of children! Warns that the failure to follow the directions given could cause serious risk to individuals or objects. WARNING:

More information

PFI Quality Assurance/Quality Control (QA/QC) Program for Residential/Commercial Densified Fuels

PFI Quality Assurance/Quality Control (QA/QC) Program for Residential/Commercial Densified Fuels PFI Quality Assurance/Quality Control (QA/QC) Program for Residential/Commercial Densified Fuels Scope: This program must be utilized by participating pellet fuel manufacturers to assure consistent quality

More information

OPERATOR'S MANUAL W Series Premium Pallet Trucks

OPERATOR'S MANUAL W Series Premium Pallet Trucks OPERATOR'S MANUAL W Series Premium Pallet Trucks JET EQUIPMENT & TOOLS, INC. P.O. BOX 1349 253-351-6000 A WMH Company Auburn, WA 98071-1349 Fax 800-274-6840 www.jettools.com e-mail jet@jettools.com M-140075

More information

SFI SPECIFICATION 1.1 EFFECTIVE: NOVEMBER 9, 2001 *

SFI SPECIFICATION 1.1 EFFECTIVE: NOVEMBER 9, 2001 * SFI SPECIFICATION 1.1 EFFECTIVE: NOVEMBER 9, 2001 * PRODUCT: Replacement Flywheels and Clutch Assemblies 1.0 GENERAL INFORMATION 1.1 This SFI Specification establishes uniform test procedures and minimum

More information

SFI SPECIFICATION 18.1 EFFECTIVE: JUNE 17, 1999 *

SFI SPECIFICATION 18.1 EFFECTIVE: JUNE 17, 1999 * SFI SPECIFICATION 18.1 EFFECTIVE: JUNE 17, 1999 * PRODUCT: Crankshaft Hub Harmonic Dampers 1.0 GENERAL INFORMATION 1.1 This SFI Specification establishes uniform test procedures and minimum standards for

More information

DEINES MANUFACTURING CORPORATION

DEINES MANUFACTURING CORPORATION DEINES MANUFACTURING CORPORATION MODEL 72 SLI DECK SUPPLEMENT PARTS AND SERVICE MANUAL DEINES MANUFACTURING CORPORATION 306 WEST HIGHWAY 4 RANSOM, KS 67572 800-624-6774 martyj@gbta.net DECK MAINTENANCE

More information

Lighting Retrofit Incentive Application for Business Customers

Lighting Retrofit Incentive Application for Business Customers Lighting Retrofit Incentive Application for Business Customers 2019 A Cash Incentive Energy Efficiency Program brought to you by: IMPORTANT INSTRUCTIONS: Step 1: Determine Eligibility: Pre-approval is

More information

Type Flexair Pneumatic Pressure Control Valves

Type Flexair Pneumatic Pressure Control Valves Industrial Hydraulics Electric Drives and Controls Linear Motion and Assembly Technologies Pneumatics Service Automation Mobile Hydraulics Type Flexair Pneumatic Pressure Control Valves Catalog pages from

More information

SFI SPECIFICATION 1.3 EFFECTIVE: MAY 23, 2000 * PRODUCT: Nitro-Methane Drag Race Multiple Disc Clutch Assemblies

SFI SPECIFICATION 1.3 EFFECTIVE: MAY 23, 2000 * PRODUCT: Nitro-Methane Drag Race Multiple Disc Clutch Assemblies SFI SPECIFICATION 1.3 EFFECTIVE: MAY 23, 2000 * PRODUCT: Nitro-Methane Drag Race Multiple Disc Clutch Assemblies 1.0 GENERAL INFORMATION 1.1 This SFI Specification establishes uniform test procedures and

More information