1 C Square Motors Catalogue-2017/12 EU MP Series HP (at 1500) 1 Electric

2 2

3 Table of contents GENERL FORMTION...5 BSIC DESIGN...6 IEC standard....6 Insulation...6 Temperature rise....6 Stator...6 Winding....6 Thermal Protection...6 Rotor...6 Vibration class and Balancing....6 Cooling and terminal box position....6 Mounting forms...6 Bearings...6 Bearing protection ring...6 Terminal box input cable...6 Earth Connection...7 Space Heaters...7 Rotor locking device...7 Painting....7 DERTG ND TOLERNCES....8 mbient temperature and altitude....8 Duty...8 Overload capacity...8 Electrical and mechanical tolerances...8 NME PLTE...9 POWER SUPPLY CONNECTION...9 OPTIONS...10 ENCODER...11 IEC FLNGE DIMENSIONS...12 PERMISSIBLE RDIL LODS...13 DT ND DRWGS IP DT ND DRWGS IP54 / IP

4 4

5 General information T-T Electric proposes a series of square frame ac motors for variable speed drives applications. This asynchronous motor has been developed and designed to achieve the same dynamic performance as for DC motors series. The C square motor complies with IEC standards and responds to the requirements for most industrial applications. Its flexible square frame design facilitates its integration into all types of machinery. MP are 3 phase asynchronous squirrel cage 4 pole motors manufactured in degree of protection IP23 and IP54/55. 9 sizes ( ) are proposed covering a power range from 16 to 1300 at TYPE OF DESIGNTION Frame Size Core Length 112,B,C 132,B,C 160,B,C 180,B,C 225,B,C 250,B,C 280,B,C 315,B,C 355,B,C,D OPERTG CURVES The mechanical and technical characteristics of MP motors can be compared to DC motors. Torque and Power curves according to Speed T = cst P = cst T = 1/n P = 1/n T = 1/n 2 N (min -1 ) Base speed Max elec speed Max mech. speed n N n 1 n max Example : MP B MP : type of motor 180 : frame size / centre height in mm 4 : number of poles B : core length 5

6 Basic design Standards IEC Insulation Class H Temperature rise Class F Stator Fully laminated square frame, low loss lamination, insulated on both faces, welded together. The number of air channels through the iron core ensure a good heat transfer. Winding Conceived in order to withstand voltage peaks (du/dt) generated by the inverter. MP 280 to 355 are wound with enamelled wires double fiber glass coated. Thermal protection PTC 150 C thermistors (3 in series) in stator winding. PTC signal cable terminals are located in the terminal box. Rotor Consists of a core of laminations with the same magnetic properties as the stator laminations, and a squirrel cage made of die-cast aluminium or copper bars for larger frames (315 and 355). The skewed rotor core has an optimized number of slots and cooling channels for smooth running, high performance and good heat transfer. Vibration Class and balancing MP motors are manufactured as standard to meet vibration class and balanced with half key. Class B is available on request. Vibrations are expressed in mm/s, rms, using free suspension method and measured under no load. Vibration Grade Displ μm Center height - mm 112 H < H 280 H > 280 Vel mm/s cc m/s 2 Displ μm Vel mm/s cc m/s 2 Displ μm Vel mm/s cc m/s B Cooling and terminal box position Standard in IP23 (MP112 to MP355): Cooling by radial mounted 3-phase fan blower located on top at N-End of the motor. Terminal box on the Right Hand Side (facing D-end). Cable outlet towards D-End. Standard in IP54 (MP112 to MP180): Cooling by axial compact mounted 3-phase fan blower, induced draught, located at the back of the motor. Terminal box on top of the motor. Cable outlet towards D-End. Standard in IP55 (MP112 to MP355): Cooling by axial mounted 3-phase fan blower located at the back of the motor. Terminal box on top of the motor. Cable outlet towards D-End. Cooling by radial mounted fan blower is possible. dvantage: possibilities to easily maint brakes, encoder assemblies Other cooling forms (in IC666, IC86W with heat exchanger) and positions for fan, terminal box and cable outlet are available on request. Power supply for blower has to be precised at the order. Motors for blower are efficiency IE3 from Blower is supplied without filter as standard. Filter on request. Mounting forms Standard IP23/IP55 Radial ventilation Standard IP54/IP55 xial ventilation : IM1001/B : IM 2001 / B : IM1001/ B3 Standard flange, see view 1b on IEC flange chart page 12. Other flange, see flange chart page 12. Bearings Grease lubricated ball bearings provided as standard for direct drive application. For pulley-belt drive, please contact our sales office. Bearing protection ring Modern variable speed drives with their fast rising voltage pulses and high switching frequencies can cause current pulses through the bearings whose repeated discharging can gradually erode the bearing races. To prevent these damages specific rules need to be respected (symmetrical multicolour motor cable, shielded, high frequency bonding connections between the installation and knows earth reference points). T-T Electric strongly recommend as a minimum the use of a bearing protection ring for motors above 100Kw. This ring is fixed on the Dend end shield and the conductive micro fibers in contact all around the rotor shaft channel harmful shaft voltages away from the bearings to around. The best solution is a bearing protection ring Dend side and an insulated bearing Nend side which cut the path to the leakage current. Terminal box input cables Provided with plugged holes: 2 for main supply and 1 for accessories. Dimensions according to table below. Type Size MP x ɸ x ɸ 20.5 MP x ɸ x ɸ 20.5 MP225 3 blank removable faces MP250 1 blank removable face MP280 1 blank removable face MP315 1 blank removable face MP355 1 blank removable face 6

7 Basic design Earth connection Terminal box is equipped with a grounding stud. From 180 frame size each foot of the motor has a threaded hole to do external earth connection. Space heaters On request motor can be equipped with space heaters, 1 per end shield, connected in parallel according to following characteristics. Power supply 230V IP23 IP54/IP55 MP112 2*40W 2*25W MP132 2*40W 2*25W MP160 2*50W 2*50W MP180 2*50W 2*50W MP225 2*80W 2*65W MP250 2*80W 2*65W MP280 2*100W 2*65W MP315 2*100W 2*100W MP355 2*150W 2*100W Rotor locking device MP 280, 315, 355 are equipped with a rotor locking device for transport. MP180, 225 & 250 are equipped with a rotor locking device when a roller bearing is mounted. Painting The standard MP surface finish has excellent resistance properties. Thickness 60 microns The painting system is suitable for humid environments. Standard colour of the motor is RL7015, machine grey. Motor Size Material Magnetic lamination Stator Stator winding Copper wire with special insulation for inverter supply End shields Material Cast Iron Bearing D-End/ND-End RS C3 C3 C3 C3 C3 C3 Lubrication Greased for life Regreasable Bearing protection ring xially locked bearings strongly recommended > 100 N-End side Terminal box Steel Cast Iron Steel Flange Steel or cast iron Cooling system luminium motor + Steel fan housing Rotor Magnetic lamination and pressure die-cast aluminium Balancing method Half key balancing and copper bars 7

8 Derating and tolerances mbient temperature and altitude Motors are designed to operate between -5 C to maximum 40 C ambient température and at a maximum altitude of 1000 m above sea level. If ambient temperature or altitude is higher the motor torque/power is derated according to the table below: Temperature ( C) ltitude (m) Duty Motor power output can be increased depending on duty types defined by IEC Correction factors are given in the table below: Duty Operating time S Cyclic duration factor 25% 40% 60% S S The maximum constant power speed will be reduced based on the type of duty and the required overload. Overload capacity: IEC standard : 160% FLT/FLC for 1 minute every 10 minutes. Electrical and mechanical tolerances Efficiency by summation losses Efficiency by input-output test Power factor Slip Max torque Inertia Noise level () <150-15% (1-) -15% (1-) -1/6 (1-) +/-20% -10% ±10% +3dB() () >150-10% (1- ) -15% (1-) -1/6 (1-) +/-20% -10% ±10% +3dB() Tolerances are in accordance with IEC and based on test procedure in accordance with IEC

9 MP nameplate Power supply connection The MP motor and its fan blower C motor have separate terminal boxes with 6 terminals inside. Connection can be star or delta according to nameplate information. W2 U2 V2 W2 U2 V2 U1 V1 W1 U1 V1 W1 Delta Connection Star Connection 9

10 Options MP Frame size MP Cooling forms IC06 (IP23) Force ventilated S S S S S S S S S IC17 (IP23) Single pipe ventilated x x x x x x x x x IC37 (IP54) Double pipe ventilated x x x x x x x x x IC416 (IP54) Totally enclosed, fan cooled S S S S S S S S S Other cooling forms available on request Mounting Forms IM1001 Horizontal foot (radial ventilation) S S S S S S S S S IM1001 Horizontal foot (axial ventilation) S S S S S S IM1002 Horizontal foot, double shaft extension x x x x x x x x x IM2001 Horizontal foot and flange (radial ventilation) x x x x x x x x x IM2001 Horizontal foot and flange (axial ventilation) S S S S x x x x x IM2011/2031 Vertical foot and flange x x x x x x x x x IM 3001/3011/3031 Horizontal/ Vertical flange R R R R R R R R R Modifications and accessories ir filter (in IP23) S S S S S S S S S ir sound absorber x x x x x x x x x ir pressure switch x x x x x x x x x PTC 150 C - 3 in series S S S S S S S S S Other temperature sensor x x x x x x x x x Bearing monitoring nipple x x x x x x x x x Special shaft x x x x x x x x x Shaft seal, D-End x x x x x x x x x Vibration class B x x x x x x x x x Roller bearing D-End x x x x x x x x x EGIS bearing protection ring x x x x x x x x x Insulated bearing, N-End x x x x x x x x x Disk Brake x x x x x x x x x Heating element x x x x x x x x x Special paint (RL colour) x x x x x x x x x Reinforced impregnation x x x x x x x x x Special corrosion protection x x x x x x x x x Special winding for 690V nominal voltage x x x x x x S S S Nema R R R R R R R R R Encoder Programmable x x x x x x x x x Not reprogrammable x x x x x x x x x S: standard x : possible R : on request 10

11 Encoder MP motors can be supplied with through hollow shaft encoder Standard encoders are: l programmable according to process requirements: - Electrical interface: 5 32 V, TTL/10-30 VDC HTL - Number of lines: up to l fixed settings: - HTL or TTL or 2048 ppr - More speed 6000 RPM Motors with radial fan are delivered with complete connector (male + female) M23 12-pin directly on the encoder. Motors with axial fan are delivered with connection to the motor N-End shield via M23 12-pin complete connector (male + female) Other types and high speed encoders are available on request. High speed design option The maximum reachable mechanical speed (indicated in pages 14 to 81.Motor characteristics part) is limited by the standard bearing. To reach higher speeds or maximum speed indicated in brackets, we propose different high speed options (2z bearings, massive cages, hybrid bearings) Please contact our sales department for more information. 11

12 Flange dimensions On request MP can be equipped with integrated or bolted flange. MP Flange size L M N P S T C F View for V View for RV 1b** 112 F b** N. F F F b** 1b** 132 F b** 1b** F F300* * 1b** F b** 1b** F F b** F b** 1b** F F F F F F F F N. F F F F F * special shaft required C dimension change from 108 to 130 ** recommended standard flange V : xial ventilation RV : Radial ventilation Others types of flange are available on request 12

13 Permissible radial loads The tables give the permissible radial loads in Newtons, assuming zero axial force. Radial force is applied at the middle of the shaft end. The values are based on normal conditions at 50 and 100 for bearing life of hours. Motors are foot mounted IM B3 horizontal position. Ball bearings Type MP MP MP MP MP C3 MP C3 MP C3 MP C3 MP C3 Distance from shaft shoulder (mm) 1500 (N) 3000 (N) (2800 ) Roller bearings Type MP112-4 NU308 ECP MP132-4 NU310 ECP MP160-4 NU214 ECP MP180-4 NU216 ECP MP225-4 NU220 ECP MP250-4 NU220 ECP MP280-4 NU224 ECP MP315-4 NU228 ECP MP355-4 NU230 ECP Distance from shaft shoulder (mm) 1500 (N) 3000 (N) (2500 ) 13

14 MP / IP23 Degree of Protection IP23 S Cooling IC06 Rotor Inertia J (kgm 2 ) Motor weight (kg) 85 n max () D-End Bearing 5000 (10600)* 6308 Sound Pressure level (db()) at 50 N-End bearing Vibration Class Mounting IM1001 Motor Nominal voltage (V) 400 Thermal Protection PTC 150 C Blower characteristics (Voltage/frequency supply to precise in order) Speed () 2800/3360 Type of cooling fan Force draught Power () 0.25/0.25 Internal Static ir Pressure Drop (Pa) 500 Current () 0.77/0.67 Required cooling ir flow (m 3 /h) ,8 0,77 17, ,8 0,82 34, ,8 0,84 41, ,8 0, ,81 0, ,81 0, ,81 0,89 83, ,81 0,

15 MP 112-4B / IP23 Degree of Protection IP23 S Cooling IC06 Rotor Inertia J (kgm 2 ) Motor weight (kg) 90 n max () 5000 (8700)* Sound Pressure level (db()) at D-End Bearing 6308 N-End bearing 6308 Vibration Class Mounting IM1001 Motor Nominal voltage (V) 400 Thermal Protection PTC 150 C Blower characteristics (Voltage/frequency supply to precise in order) Speed () 2800/3360 Type of cooling fan Force draught Power () 0.25/0.25 Internal Static ir Pressure Drop (Pa) 500 Current () 0.77/0.67 Required cooling ir flow (m3/h) ,8 0,79 17, ,8 0,84 34, ,8 0,86 41, ,8 0,88 52, ,81 0,89 62, ,81 0,9 69, ,81 0,91 83, ,81 0,92 104,2 15

16 MP 112-4C / IP23 Degree of Protection IP23 S Cooling IC06 Rotor Inertia J (kgm 2 ) Motor weight (kg) 120 n max () D-End Bearing 5000 (7500)* 6308 Sound Pressure level (db()) at 50 N-End bearing Vibration Class Mounting IM1001 Motor Nominal voltage (V) 400 Thermal Protection PTC 150 C Blower characteristics (Voltage/frequency supply to precise in order) Speed () 2810/3360 Type of cooling fan Force draught Power () 0.25/0.25 Internal Static ir Pressure Drop (Pa) 500 Current () 0.77/0.67 Required cooling ir flow (m 3 /h) ,8 0,8 17, ,8 0,85 34, ,8 0,87 41, ,8 0, , ,8 0,9 62, ,81 0,91 69, ,81 0,92 83, ,81 0,

17 MP / IP23 Degree of Protection IP23 S Cooling IC06 Rotor Inertia J (kgm 2 ) 0.08 Motor weight (kg) 166 n max () D-End Bearing 4300 (10500)* 6310 Blower characteristics (Voltage/frequency supply to precise in order) Sound Pressure level (db()) at 50 N-End bearing Speed () 2800/3360 Type of cooling fan Force draught Power () 0.55/0.55 Internal Static ir Pressure Drop (Pa) 500 Current () 1.4/1.22 Required cooling ir flow (m3/h) Vibration Class Mounting IM1001 Motor Nominal voltage (V) 400 Thermal Protection PTC 150 C ,8 0,8 17, ,8 0,85 34, ,8 0,87 41, ,8 0, ,8 0,9 62, ,81 0,91 69, ,81 0,92 83, * 0,81 0,

18 MP 132-4B / IP23 Degree of Protection IP23 S Cooling IC06 Rotor Inertia J (kgm 2 ) 0.09 Motor weight (kg) 175 n max () D-End Bearing Blower characteristics (Voltage/frequency supply to precise in order) Speed () 2800/3360 Type of cooling fan Force draught Power () 0.55/0.55 Internal Static ir Pressure Drop (Pa) 500 Current () 1.4/1.22 Required cooling ir flow (m 3 /h) (8700)* 6310 Sound Pressure level (db()) at 50 N-End bearing ,79 0,81 18, ,8 0,86 35, ,81 0,88 41, ,82 0,9 52, ,82 0,91 62, ,82 0,92 68, ,82 0,93 83, * 0,82 0,94 101, Vibration Class Mounting IM1001 Motor Nominal voltage (V) 400 Thermal Protection PTC 150 C 18

19 MP 132-4C / IP23 Degree of Protection IP23 S Cooling IC06 Rotor Inertia J (kgm 2 ) 0.11 Motor weight (kg) 205 n max () D-End Bearing 4300 (7400)* 6310 Sound Pressure level (db()) at 50 N-End bearing Speed () 2800/3360 Type of cooling fan Force draught Power () 0.55/0.55 Internal Static ir Pressure Drop (Pa) 500 Current () 1.4/1.22 Required cooling ir flow (m3/h) Vibration Class Mounting IM1001 Motor Nominal voltage (V) 400 Thermal Protection PTC 150 C Blower characteristics (Voltage/frequency supply to precise in order) ,79 0,81 18, ,8 0,86 35, ,81 0,88 41, ,82 0,9 52, ,82 0,91 62, ,82 0,92 68, ,82 0,93 83, * 0,82 0,95 101,9 19

20 MP / IP23 Degree of Protection IP23 S Cooling IC06 Rotor Inertia J (kgm 2 ) 0.24 Motor weight (kg) 290 n max () D-End Bearing 3400 (9500)* 6214 Sound Pressure level (db()) at 50 N-End bearing Speed () 2885/3462 Type of cooling fan Force draught Power () 1.1/1.1 Internal Static ir Pressure Drop (Pa) 850 Current () 2.31/1,98 Required cooling ir flow (m 3 /h) Vibration Class Mounting IM1001 Motor Nominal voltage (V) 400 Thermal Protection PTC 150 C Blower characteristics (Voltage/frequency supply to precise in order) ,8 0, ,8 0,89 34, ,8 0, ,8 0,93 51, ,8 0,93 61, ,8 0, * 0,8 0, * 0,8 0,96 101,5 20

21 MP 160-4B / IP23 Degree of Protection IP23 S Cooling IC06 Rotor Inertia J (kgm 2 ) 0.29 Motor weight (kg) 335 n max () D-End Bearing** Speed () 2885/3462 Type of cooling fan Force draught Power () 1.1/1.1 Internal Static ir Pressure Drop (Pa) 850 Current () 2.31/1.98 Required cooling ir flow (m 3 /h) (7500)* 6214 Sound Pressure level (db()) at 50 N-End bearing ,82 0, ,81 0,89 34, ,82 0, ,82 0,93 51, ,82 0,94 61, ,82 0,95 68, * 0,83 0,95 82, * 0,83 0,96 101, Vibration Class Mounting IM1001 Motor Nominal voltage (V) 400 Thermal Protection PTC 150 C **Bearing protection ring recommended > 100 Blower characteristics (Voltage/frequency supply to precise in order) 21

22 MP 160-4C / IP23 Degree of Protection IP23 S Cooling IC06 Rotor Inertia J (kgm 2 ) 0.33 Motor weight (kg) 370 n max () D-End Bearing** 3400 (6300)* 6214 Sound Pressure level (db()) at 50 N-End bearing Speed () 2885/3462 Type of cooling fan Force draught Power () 1.1/1.1 Internal Static ir Pressure Drop (Pa) 850 Current () 2.31/1.98 Required cooling ir flow (m 3 /h) Vibration Class Mounting IM1001 Motor Nominal voltage (V) 400 Thermal Protection PTC 150 C **Bearing protection ring recommended > 100 Blower characteristics (Voltage/frequency supply to precise in order) ,78 0,84 18, ,79 0,89 35, ,79 0,91 41, ,79 0,93 52, ,79 0,94 62, ,8 0,95 68, * 0,8 0, * 0,8 0,96 101,9 22

23 MP / IP23 Degree of Protection IP23 S Cooling IC06 Rotor Inertia J (kgm 2 ) 0.54 Motor weight (kg) 365 n max () D-End Bearing** 3000 (7800)* 6216 Sound Pressure level (db()) at 50 N-End bearing Speed () 2885/3474 Type of cooling fan Force draught Power () 1.5/2.2 Internal Static ir Pressure Drop (Pa) 900 Current () 3.06/3.76 Required cooling ir flow (m 3 /h) Vibration Class Mounting IM1001 Motor Nominal voltage (V) 400 Thermal Protection PTC 150 C **Bearing protection ring recommended > 100 Blower characteristics (Voltage/frequency supply to precise in order) ,84 0,84 17, ,83 0,89 34, ,83 0,91 40, ,84 0,93 50, ,84 0,94 60, * 0,84 0,95 67, * 0,84 0,95 81, * 0,85 0,

24 MP 180-4B / IP23 Degree of Protection IP23 S Cooling IC06 Rotor Inertia J (kgm 2 ) 0.74 Motor weight (kg) 450 n max () D-End Bearing** Speed () 2885/3474 Type of cooling fan Force draught Power () 1.5/2.2 Internal Static ir Pressure Drop (Pa) 900 Current () 3.06/3.76 Required cooling ir flow (m 3 /h) (6700)* 6216 Sound Pressure level (db()) at 50 N-End bearing ,84 0,85 17, ,84 0, ,84 0,92 40, ,85 0,94 50, ,85 0,94 60, * 0,85 0,95 67, * 0,85 0,95 81, * 0,85 0, Vibration Class Mounting IM1001 Motor Nominal voltage (V) 400 Thermal Protection PTC 150 C **Bearing protection ring recommended > 100 Blower characteristics (Voltage/frequency supply to precise in order) 24

25 MP 180-4C / IP23 Degree of Protection IP23 S Cooling IC06 Rotor Inertia J (kgm 2 ) 0.94 Motor weight (kg) 545 n max () 3000 (4900)* Sound Pressure level (db()) at D-End Bearing** 6216 N-End bearing 6216 Vibration Class Mounting IM1001 Motor Nominal voltage (V) 400 Thermal Protection PTC 150 C **Bearing protection ring recommended > 100 Blower characteristics (Voltage/frequency supply to precise in order) Speed () 2885/3474 Type of cooling fan Force draught Power () 1.5/2.2 Internal Static ir Pressure Drop (Pa) 900 Current () 3.06/3.76 Required cooling ir flow (m 3 /h) ,83 0,85 17, ,84 0,9 34, ,84 0,92 40, ,85 0,94 50, ,85 0,94 61, * 0,85 0,95 67, * 0,85 0,95 81, * 0,86 0,96 100,9 25

26 MP / IP23 Degree of Protection IP23 S Cooling IC06 Rotor Inertia J (kgm 2 ) 1.72 Motor weight (kg) 705 n max () 3800 (6000)* Sound Pressure level (db()) at D-End Bearing** 6220C3 N-End bearing 6220C3 Vibration Class Mounting IM1001 Motor Nominal voltage (V) 400 Thermal Protection PTC 150 C **Bearing protection ring recommended > 100 Blower characteristics (Voltage/frequency supply to precise in order) Speed () 2915/3474 Type of cooling fan Force draught Power () 3/4 Internal Static ir Pressure Drop (Pa) 1200 Current () 5.71/6.45 Required cooling ir flow (m 3 /h) ,84 0,86 17, ,84 0, ,84 0,93 40, ,85 0,95 50, ,85 0,95 60, ,85 0,96 67, * 0,85 0, * 0,86 0,96 100,8 26

27 MP 225-4B / IP23 Degree of Protection IP23 S Cooling IC06 Rotor Inertia J (kgm 2 ) 2.29 Motor weight (kg) 860 n max () 3800 (5000)* Sound Pressure level (db()) at 50 D-End Bearing** 6220C3 N-End bearing 6220C3 Vibration Class Mounting IM1001 Motor Nominal voltage (V) 400 Thermal Protection PTC 150 C **Bearing protection ring recommended > Blower characteristics (Voltage/frequency supply to precise in order) Speed () 2915/3474 Type of cooling fan Force draught Power () 3/4 Internal Static ir Pressure Drop (Pa) 1200 Current () 5.71/6.45 Required cooling ir flow (m 3 /h) ,84 0,86 17, ,85 0,91 33, ,85 0,93 40, ,85 0,95 50, ,85 0,95 60, ,85 0,96 67, * 0,85 0,96 80, * 0,86 0,96 100,8 27

28 MP 225-4C / IP23 Degree of Protection IP23 S Cooling IC06 Rotor Inertia J (kgm 2 ) 2.55 Motor weight (kg) 920 n max () 3800 (4400)* Sound Pressure level (db()) at 50 D-End Bearing** 6220C3 N-End bearing 6220C3 Vibration Class Mounting IM1001 Motor Nominal voltage (V) 400 Thermal Protection PTC 150 C **Bearing protection ring recommended > 100 Blower characteristics (Voltage/frequency supply to precise in order) Speed () 2915/3474 Type of cooling fan Force draught Power () 3/4 Internal Static ir Pressure Drop (Pa) 1200 Current () 5.71/6,45 Required cooling ir flow (m 3 /h) ,84 0,86 17, ,83 0, ,83 0,93 40, ,84 0,95 50, ,84 0,95 60, ,84 0,95 67, * 0,84 0, * 0,85 0,

29 MP / IP23 Degree of Protection IP23 Cooling IC06 Rotor Inertia J (kgm 2 ) 2.8 Motor weight (kg) 1090 n max () 3400 (5700)* Sound Pressure level (db()) at 50 D-End Bearing** 6222C3 N-End bearing 6222C3 Vibration Class Mounting IM1001 Motor Nominal voltage (V) 400 Thermal Protection PTC 150 C **Bearing protection ring recommended > Blower characteristics (Voltage/frequency supply to precise in order) Speed () 2925/3510 Type of cooling fan Force draught Power () 5.5/7.5 Internal Static ir Pressure Drop (Pa) 2100 Current () 10.1/11.86 Required cooling ir flow (m 3 /h) ,84 0,86 16, ,84 0,91 33, ,84 0,93 40, ,85 0,95 50, ,85 0,95 60, ,85 0,96 67, * 0,85 0,96 80, * 0,86 0,96 87,5 29

30 MP 250-4B / IP23 Degree of Protection IP23 Cooling IC06 Rotor Inertia J (kgm 2 ) 3.4 Motor weight (kg) 1260 n max () 3400 (4600)* Sound Pressure level (db()) at 50 D-End Bearing** 6222C3 N-End bearing 6222C3 Vibration Class Mounting IM1001 Motor Nominal voltage (V) 400 Thermal Protection PTC 150 C **Bearing protection ring recommended > Blower characteristics (Voltage/frequency supply to precise in order) Speed () 2925/3510 Type of cooling fan Force draught Power () 5.5/7.5 Internal Static ir Pressure Drop (Pa) 2100 Current () 10.1/11.86 Required cooling ir flow (m 3 /h) ,84 0,86 16, ,84 0,91 33, ,84 0,93 40, ,85 0,95 50, ,85 0,95 60, ,85 0,96 67, * 0,85 0,96 80, * 0,86 0,

31 MP 250-4C / IP23 Degree of Protection IP23 Cooling IC06 Rotor Inertia J (kgm 2 ) 3.8 Motor weight (kg) 1390 n max () 3400 (3900)* Sound Pressure level (db()) at 50 D-End Bearing** 6222C3 N-End bearing 6222C3 Vibration Class Mounting IM1001 Motor Nominal voltage (V) 400 Thermal Protection PTC 150 C **Bearing protection ring recommended > Blower characteristics (Voltage/frequency supply to precise in order) Speed () 2925/3510 Type of cooling fan Force draught Power () 5.5/7.5 Internal Static ir Pressure Drop (Pa) 2100 Current () 10.1/11.86 Required cooling ir flow (m 3 /h) ,84 0,86 16, ,84 0,91 33, ,84 0,93 40, ,85 0,95 50, ,85 0,95 60, ,85 0,96 67, * 0,85 0,96 80, * 0,86 0,

32 MP / IP23 Degree of Protection IP23 S Cooling IC06 Rotor Inertia J (kgm 2 ) 4.17 Motor weight (kg) 1160 n max () 3200 (5000)* Sound Pressure level (db()) at 50 D-End Bearing** 6224C3 N-End bearing 6224C3 Vibration Class Mounting IM1001 Motor Nominal voltage (V) 400*** Thermal Protection PTC 150 C **Bearing protection ring recommended > 100 *** 690V possible on request Blower characteristics (Voltage/frequency supply to precise in order) Speed () 2925/3510 Type of cooling fan Force draught Power () 5.5/7.5 Internal Static ir Pressure Drop (Pa) 2600 Current () 10.1/11.86 Required cooling ir flow (m 3 /h) ,85 0,86 17, ,86 0,91 33, ,86 0,93 40, ,87 0,95 50, ,87 0,95 60, ,87 0,95 67,1 32

33 MP 280-4B / IP23 Degree of Protection IP23 S Cooling IC06 Rotor Inertia J (kgm 2 ) 5.5 Motor weight (kg) 1510 n max () 3200 (4200)* Sound Pressure level (db()) at 50 D-End Bearing** 6224C3 N-End bearing 6224C3 Vibration Class Mounting IM1001 Motor Nominal voltage (V) 400*** Thermal Protection PTC 150 C **Bearing protection ring recommended > 100 *** 690V possible on request Blower characteristics (Voltage/frequency supply to precise in order) Speed () 2925/3510 Type of cooling fan Force draught Power () 5.5/7.5 Internal Static ir Pressure Drop (Pa) 2600 Current () 10.1/11.86 Required cooling ir flow (m 3 /h) ,87 0,87 17, ,88 0,92 33, ,88 0,94 40, ,88 0,96 50, ,88 0,96 60, ,88 0,96 67,1 33

34 MP 280-4C / IP23 Degree of Protection IP23 S Cooling IC06 Rotor Inertia J (kgm 2 ) 6.2 Motor weight (kg) 1800 n max () 3200 (4000)* Sound Pressure level (db()) at 50 D-End Bearing** 6224C3 N-End bearing 6224C3 Vibration Class Mounting IM1001 Motor Nominal voltage (V) 400*** Thermal Protection PTC 150 C **Bearing protection ring recommended > 100 *** 690V possible on request Blower characteristics (Voltage/frequency supply to precise in order) Speed () 2925/3510 Type of cooling fan Force draught Power () 5.5/7.5 Internal Static ir Pressure Drop (Pa) 2600 Current () 10.1/11.86 Required cooling ir flow (m 3 /h) ,84 0, ,85 0,92 33, ,85 0,94 40, ,85 0,96 50, ,85 0,96 60, ,85 0,96 67,1 34

35 Ø Ø265 Ø Ø265 MP / IP23 Degree of Protection IP23 S Cooling IC06 Rotor Inertia J (kgm 2 ) 12.9 Motor weight (kg) 2120 n max () 3000 (4300)* Sound Pressure level (db()) at 50 D-End Bearing** 6228C3 N-End bearing 6228C3 Vibration Class Mounting IM1001 Motor Nominal voltage (V) 400*** Thermal Protection PTC 150 C **Bearing protection ring recommended > 100 *** 690V possible on request 85 Blower characteristics (Voltage/frequency supply to precise in order) Speed () 2925/3510 Type of cooling fan Force draught Power () 5.5/7.5 Internal Static ir Pressure Drop (Pa) 3500 Current () 10.1/11.86 Required cooling ir flow (m 3 /h) 4400 C ,85 0,86 17,1 DETIL ,86 0, , ,86 0,93 40,3 C D DTE MODIFICTION NOM 1 21/04/2015 Mise en place nouvelle BàB M-E ,87 0,95 50, ,87 0,95 60, * 0,87 0,95 67, Ø D DTE MODIFICTION NOM 1 21/04/2015 Mise en place nouvelle BàB M-E Ø DETIL IC:06 IP: IM:1001 Pos: CDH/257 Encoder with cover C VIEW ,5 M30x Encoder with cover C VIEW ,5 M30x IC:06 IP:23 IM:1001 Pos: CDH/257 T-T Electric Dessiné MNESSE E , Rue du 8 Mai PERSN Tél.: Fax :

36 Ø Ø MP 315-4B / IP23 Degree of Protection IP23 S Cooling IC06 Rotor Inertia J (kgm 2 ) 16.1 Motor weight (kg) 2540 n max () **Bearing protection ring recommended > 100 *** 690V possible on request 3000 (3200)* Sound Pressure level (db()) at 50 D-End Bearing** 6228C3 N-End bearing 6228C3 Vibration Class Mounting IM1001 Motor Nominal voltage (V) 400*** Thermal Protection PTC 150 C Blower characteristics (Voltage/frequency supply to precise in order) Speed () 2925/3510 Type of cooling fan Force draught Power () 5.5/7.5 Internal Static ir Pressure Drop (Pa) 3500 Current () 10.1/11.86 Required cooling ir flow (m 3 /h) ,87 0,87 17, ,87 0,92 33, ,87 0, ,3 C D DTE MODIFICTION NOM 1 21/04/2015 Mise en place nouvelle BàB M-E DETIL ,87 0,96 50, ,87 0,96 60, * 0,87 0,96 67,1 160 C D DTE MODIFICTION NOM 1 21/04/2015 Mise en place nouvelle BàB M-E DETIL Ø Encoder with cover C VIEW ,5 M30x IC:06 IP:23 IM:1001 Pos: CDH/257 Ø IC:06 IP:23 IM: Pos: CDH/257 Encoder with cover C VIEW T-T Electric 36 Dessiné Vérifié ,5 M30x3.5 MNESSE E BUMBC S , Rue du 8 Mai PERSN Tél.: Fax : DIMENSION DRWG 131

37 Ø Ø MP 315-4C / IP23 Degree of Protection IP23 S Cooling IC06 Rotor Inertia J (kgm 2 ) Motor weight (kg) 2930 n max () 2600 Sound Pressure level (db()) at 50 D-End Bearing** 6228C3 N-End bearing 6228C3 Vibration Class Mounting IM1001 Motor Nominal voltage (V) 400*** Thermal Protection PTC 150 C **Bearing protection ring recommended > 100 *** 690V possible on request Blower characteristics (Voltage/frequency supply to precise in order) Speed () 2925/3510 Type of cooling fan Force draught Power () 5.5/7.5 Internal Static ir Pressure Drop (Pa) 3500 Current () 10.1/11.86 Required cooling ir flow (m 3 /h) C ,84 0, ,85 0,92 33, ,85 0,94 40, ,86 0, , ,86 0,96 60, ,86 0,96 67, C 800 Ø D DTE MODIFICTION NOM 1 21/04/2015 Mise en place nouvelle BàB M-E DETIL 32 IC: IP:23 IM:1001 Encoder Pos: CDH/257 with cover ,5 800 Ø M30x3.5 C VIEW DETIL D DTE MODIFICTION NOM 1 21/04/2015 Mise en place nouvelle BàB M-E 120 Encoder with cover ,5 131 M30x3.5 IC:06 IP:23 IM:1001 Pos: CDH/257 C VIEW 320 T-T Electric , Rue du 8 Mai PERSN Tél.: Fax : Dessiné MNESSE E

38 0 8, ,5 Ø Ø Ø75 MP / IP23 Degree of Protection IP23 S Cooling IC06 Rotor Inertia J (kgm 2 ) Motor weight (kg) 2100 n max () 2800 (4200)* Sound Pressure level (db()) at 50 D-End Bearing** 6230 C3 N-End bearing 6230 C3 Vibration Class Mounting IM1001 Motor Nominal voltage (V) 400*** Thermal Protection PTC 150 C ** Insulated bearing or similar solution recommended above 100 *** 690V possible on request Blower characteristics (Voltage/frequency supply to precise in order) Speed () 2925/1752 Type of cooling fan Force draught Power () 5.5/7.5 Internal Static ir Pressure Drop (Pa) 3300 Current () 10.1/12.22 Required cooling ir flow (m 3 /h) ,86 0, ,87 0,92 33, ,87 0,94 40, ,88 0,96 50, * 200 0,88 0,96 60, * 0,88 0,96 66,9 532, C 250 D DTE MODIFICTION NOM 3 21/04/2015 Changement de BàB M- E , Ø28 D DTE 3 21/04/2015 Changem Encoder with cover DET D DTE MODIFICTION NOM 3 21/04/2015 Changement de BàB M- E VUE C , C C 200 VUE C Ø Ø Encoder with cover Encoder with cover DETIL 32 DETIL IC:06 IP:23 IM:1001 Pos: CDH/257 VUE C M30x3.5 M30x3.5 MP355-4 This document must not be copied without our written permission, and the contents should not be sent to a third party or used without our authorization. Contravention will be prosecuted T-T Electric Ce document ne doit pas être copié sans notre autorisation écrite, et son contenu ne peut pas être confié à un tiers ni Dessiné Vérifié Norme 2768 pl Masse ECHELLE 1/2 Ra in MNESSE E BUMBC S 22, Rue du 8 Mai PERSN Tél.: Fax : DIMENSION D PLN D'ENCOM FR

39 , Ø75 Ø Ø75 MP 355-4B / IP23 Degree of Protection IP23 S Cooling IC06 Rotor Inertia J (kgm 2 ) Motor weight (kg) 2800 n max () 2800 (4200)* Sound Pressure level (db()) at 50 D-End Bearing** 6230 C3 N-End bearing 6230 C3 Vibration Class Mounting IM1001 Motor Nominal voltage (V) 400*** Thermal Protection PTC 150 C ** Insulated bearing or similar solution recommended above 100 ** 690V possible on request Blower characteristics (Voltage/frequency supply to precise in order) Speed () 2925/1752 Type of cooling fan Force draught Power () 5.5/7.5 Internal Static ir Pressure Drop (Pa) 3300 Current () 10.1/12.22 Required cooling ir flow (m 3 /h) ,85 0, ,86 0,92 33, , ,94 40, ,87 0,96 50, * 0,87 0,96 60, * C 0,87 0,96 66,9 734, Encoder with cover D DTE 3 21/04/ , , D DTE MODIFICTION NOM 570 Ø /04/2015 Chandement de BàB M-E D DTE MODIFICTION NOM /04/2015 Chandement de BàB M-E VUE C DET M30x3.5 C Encoder Encoder with cover with cover VUE C VUE C 570 Ø Ø DETIL DETIL IC:06 IP:23 IM:1001 Pos: CDH/257 M30x3.5 M30x MP355-4B This document must not be copied without our written permission, and the contents should not be sent to a third party or used without our authorization. Contravention will be prosecuted T-T Electric Ce document ne doit pas être copié sans notre Dessiné Vérifié Norme 2768 pl Masse ECHELLE 1/20 MNESSE E BUMBC S 22, Rue du 8 Mai PERSN Tél.: Fax : DIMENSION PLN D'ENCO

40 , Ø Ø Ø75 MP 355-4C / IP23 Degree of Protection IP23 S Cooling IC06 Rotor Inertia J (kgm 2 ) 25.7 Motor weight (kg) 3400 n max () ** Insulated bearing or similar solution recommended above 100 ** 690V possible on request 2800 (3600)* Sound Pressure level (db()) at 50 D-End Bearing** 6230 C3 N-End bearing 6230 C3 Vibration Class Mounting IM2001 Motor Nominal voltage (V) 400*** Thermal Protection PTC 150 C Blower characteristics (Voltage/frequency supply to precise in order) Speed () 2925/1752 Type of cooling fan Force draught Power () 5.5/7.5 Internal Static ir Pressure Drop (Pa) 3300 Current () 10.1/12.22 Required cooling ir flow (m 3 /h) ,85 0, ,86 0,92 33, ,86 0,94 40, ,87 0,96 50, * 0,87 0,96 60, * 0,87 0,96 66,9 C , Encoder with cover D DTE 3 21/04/ , D DTE MODIFICTION NOM 670 Ø /04/2015 Chandement de 254 BàB M-E DE 834, D DTE MODIFICTION NOM 3 21/04/2015 Chandement de BàB M-E VUE C M30x3.5 C C Ø Ø Encoder with cover VUE CVUE C Encoder with cover M30x3.5 DETIL 32 DETIL M30x MP355-4C This document must not be copied without our written permission, and the contents should not be sent to a third party or used without our authorization. Contravention will be prosecuted T-T Electric Dessiné Vérifié Norme 2768 pl Masse MNESSE E BUMBC S IC:06 IP:23 IM:1001 Pos: CDH/257 22, Rue du 8 Mai PERSN Tél.: Fax : DIMENSION PLN D'ENCO

41 Ø75 Ø75 MP 355-4D / IP23 Degree of Protection IP23 S Cooling IC06 Rotor Inertia J (kgm 2 ) Motor weight (kg) 4000 n max () On request (high speed option) Insulated bearing or similar solution recommended above V possible on request 2700 Sound Pressure level (db()) at 50 D-End Bearing** 6230 C3 N-End bearing 6230 C3 Vibration Class Mounting IM1001 Motor Nominal voltage (V) 400 Thermal Protection PTC 150 C Blower characteristics (Voltage/frequency supply to precise in order) Speed () 2925/1752 Type of cooling fan Force draught Power () 5.5/7.5 Internal Static ir Pressure Drop (Pa) 3300 Current () 10.1/12.22 Required cooling ir flow (m 3 /h) ,85 0, ,86 0,92 33, ,86 0,94 40, ,87 0,96 50, ,87 0,96 60, ,87 0,96 66,9 C , D DTE M 3 21/04/2015 Chandemen Encoder with cover 1064, , D DTE MODIFICTION NOM 3 21/04/2015 Chandement de BàB M- E D DTE MODIFICTION NOM 3 21/04/2015 Chandement de BàB M- E VUE C 900 Ø Ø75 18 DET C 200 C Encoder Encoder with cover with cover 1472 M30x VUE C Ø VUE C Ø M30x3.5 DETIL 32 M30x3.5 DETIL MP355-4D This document must not be copied without our written permission, and the contents should not be sent to a third party or used without our authorization. Contravention will be prosecuted T-T Electric Ce document ne doit pas être copié sans notre autorisation écrite, et son contenu ne peut pas être confié à un tiers ni utilisé sans notre accord.tout contrefacteur sera poursuivi. T-T Electric Dessiné Vérifié Norme Masse ECHELLE pl 1/20 Ra in microns 152,5 MNESSE E BUMBC S IC:06 IP:23 IM:1001 Pos: CDH/257 22, Rue du 8 Mai PERSN Tél.: Fax : DIMENSION DR PLN D'ENCOMB FR

42 MP / IP54-IP55 Degree of Protection IP55 Cooling IC416 Rotor Inertia J (kgm 2 ) 0.08 Motor weight (kg) 170 n max () D-End Bearing 4300 (6700)* 6310 Sound Pressure level (db()) at 50 N-End bearing Vibration Class Mounting IM1001** Motor Nominal voltage (V) 400 Thermal Protection PTC 150 C ** IM2001 for axial ventilation IP54 version, xial ventilation, Fan characteristics Frequency () 50/60 Number of phases 1 Voltage (V) 230 Mounting xial Speed () 2607/3130 Type of cooling fan Induced draught Power () 0.26/0.25 Current () 1.18/1.15 IP55 version, xial or radial ventilation, Fan characteristics (Voltage/frequency supply to precise in order) Speed () 2800/3360 Type of cooling fan Force draught Power () 0.55/0.55 Internal Static ir Pressure Drop (Pa) 500 Current () 1.4/1.22 Required cooling ir flow (m 3 /h) ,81 0, ,82 0, ,82 0,89 41, ,83 0, ,83 0, ,84 0, ,85 0, * 0,87 0, * with MP160 blower characteristics IP55 only drawing on request. 42

43 MP / IP54-IP55 IP54 version, axial ventilation IP55 version, axial ventilation IP55 version, radial ventilation 43

44 MP 132-4B / IP54-IP55 Degree of Protection IP55 Cooling IC416 Rotor Inertia J (kgm 2 ) 0.09 Motor weight (kg) 180 n max () D-End Bearing 4300 (6700)* 6310 Sound Pressure level (db()) at 50 N-End bearing Vibration Class Mounting IM1001** Motor Nominal voltage (V) 400 Thermal Protection PTC 150 C ** IM2001 for axial ventilation IP54 version, xial ventilation, Fan characteristics Frequency () 50/60 Number of phases 1 Voltage (V) 230 Mounting xial Speed () 2607/3130 Type of cooling fan Induced draught Power () 0.26/0.25 Current () 1.18/1.15 IP55 version, xial or radial ventilation, Fan characteristics (Voltage/frequency supply to precise in order) Speed () 2800/3360 Type of cooling fan Force draught Power () 0.55/0.55 Internal Static ir Pressure Drop (Pa) 500 Current () 1.4/1.22 Required cooling ir flow (m 3 /h) ,79 0, ,8 0,89 35, ,8 0,9 41, ,81 0,91 52, ,81 0, ,82 0,92 68, ,83 0,92 83,2 * * 0,85 0,93 102,4 * with MP 160 blower characteristics IP55 only drawing on request 44

45 MP 132-4B / IP54-IP55 IP54 version, axial ventilation IP55 version, axial ventilation IP55 version, radial ventilation 45

46 MP 132-4C / IP54-IP55 Degree of Protection IP55 Cooling IC416 Rotor Inertia J (kgm 2 ) 0.11 Motor weight (kg) 205 n max () D-End Bearing 4300 (6700)* 6310 Sound Pressure level (db()) at 50 N-End bearing Vibration Class Mounting IM1001** Motor Nominal voltage (V) 400 Thermal Protection PTC 150 C ** IM2001 for axial ventilation IP54 version, xial ventilation, Fan characteristics Frequency () 50/60 Number of phases 1 Voltage (V) 230 Mounting xial Speed () 2607/3130 Type of cooling fan Induced draught Power () 0.26/0.25 Current () 1.18/1.15 IP55 version, xial or radial ventilation, Fan characteristics (Voltage/frequency supply to precise in order) Speed () 2800/3360 Type of cooling fan Force draught Power () 0.55/0.55 Internal Static ir Pressure Drop (Pa) 500 Current () 1.4/1.22 Required cooling ir flow (m 3 /h) ,81 0,86 18, ,82 0,89 35, ,82 0,9 41, ,83 0,91 51, ,83 0, ,84 0,92 68, ,85 0,92 82,8 * * 0,87 0,93 101,7 * with MP 160 blower characteristics IP55 only drawing on request 46

47 MP 132-4C / IP54-IP55 IP54 version, axial ventilation IP55 version, axial ventilation IP55 version, radial ventilation 47

48 MP / IP54-IP55 Degree of Protection IP55 Cooling IC416 Rotor Inertia J (kgm 2 ) 0.24 Motor weight (kg) 295 n max () D-End Bearing 3400 (5600)* 6214 Sound Pressure level (db()) at 50 N-End bearing Vibration Class Mounting IM1001** Motor Nominal voltage (V) 400 Thermal Protection PTC 150 C ** IM2001 for axial ventilation IP54 version, xial ventilation, Fan characteristics Voltage (V) 400/460 Mounting xial Speed () 2480/3050 Type of cooling fan Induced draught Power () 0.79/0.9 Current () 1.3/1.3 IP55 version, xial or radial ventilation, Fan characteristics (Voltage/frequency supply to precise in order) Speed () 2885/3462 Type of cooling fan Force draught Power () 1.1/1.1 Internal Static ir Pressure Drop (Pa) 850 Current () 2.31/1.98 Required cooling ir flow (m 3 /h) ,77 0, ,78 0,91 34, ,78 0,92 41, ,79 0,93 51, * 0,79 0,93 61, * 0,8 0, * 0,81 0,94 82, * 0,83 0,95 101,4 48

49 MP / IP54-IP55 IP54 version, axial ventilation IP55 version, axial ventilation IP55 version, radial ventilation 49

50 MP 160-4B / IP54-IP55 Degree of Protection IP55 Cooling IC416 Rotor Inertia J (kgm 2 ) 0.29 Motor weight (kg) 340 n max () D-End Bearing 3400 (5600)* 6214 Sound Pressure level (db()) at 50 N-End bearing Vibration Class Mounting IM1001** Motor Nominal voltage (V) 400 Thermal Protection PTC 150 C ** IM2001 for axial ventilation IP54 version, xial ventilation, Fan characteristics Voltage (V) 400/460 Mounting xial Speed () 2480/3050 Type of cooling fan Induced draught Power () 0.79/0.9 Current () 1.3/1.3 IP55 version, xial or radial ventilation, Fan characteristics (Voltage/frequency supply to precise in order) Speed () 2885/3462 Type of cooling fan Force draught Power () 1.1/1.1 Internal Static ir Pressure Drop (Pa) 850 Current () 2.31/1.98 Required cooling ir flow (m 3 /h) ,79 0,89 17, ,8 0,92 34, ,8 0,93 40, ,81 0,94 51, * 0,81 0,94 61, * 0,82 0,95 67, * 0,83 0,95 81, * 0,85 0,96 101,1 50

51 MP 160-4B / IP54-IP55 IP54 version, axial ventilation IP55 version, axial ventilation IP55 version, radial ventilation 51

52 MP 160-4C / IP54 Degree of Protection IP55 Cooling IC416 Rotor Inertia J (kgm 2 ) 0.33 Motor weight (kg) 375 n max () D-End Bearing 3400 (5600)* 6214 Sound Pressure level (db()) at 50 N-End bearing Vibration Class Mounting IM1001** Motor Nominal voltage (V) 400 Thermal Protection PTC 150 C ** IM2001 for axial ventilation IP54 version, xial ventilation, Fan characteristics Voltage (V) 400/460 Mounting xial Speed () 2480/3050 Type of cooling fan Induced draught Power () 0.79/0.9 Current () 1.3/1.3 IP55 version, xial or radial ventilation, Fan characteristics (Voltage/frequency supply to precise in order) Speed () 2885/3462 Type of cooling fan Force draught Power () 1.1/1.1 Internal Static ir Pressure Drop (Pa) 850 Current () 2.31/1.98 Required cooling ir flow (m 3 /h) ,7 0,89 17, ,71 0,92 34, ,71 0,93 40, ,72 0, * 0,72 0,94 61, * 0,73 0,95 67, * 0,74 0,95 81, * 0,76 0,

53 MP 160-4C / IP54 IP54 version, axial ventilation IP55 version, axial ventilation IP55 version, radial ventilation 53

54 MP / IP54-IP55 Degree of Protection IP55 Cooling IC416 Rotor Inertia J (kgm 2 ) 0.54 Motor weight (kg) 370 n max () D-End Bearing 3000 (4800)* 6216 Sound Pressure level (db()) at 50 N-End bearing Vibration Class Mounting IM1001** Motor Nominal voltage (V) 400 Thermal Protection PTC 150 C * Can be increased on request ** IM2001 for axial ventilation IP54 version, xial ventilation, Fan characteristics Voltage (V) 400/460 Mounting xial Speed () 2480/3050 Type of cooling fan Induced draught Power () 0.79/0.9 Current () 1.3/1.3 IP55 version, xial or radial ventilation, Fan characteristics (Voltage/frequency supply to precise in order) Speed () 2885/3462 Type of cooling fan Force draught Power () 1.5/1.5 Internal Static ir Pressure Drop (Pa) 900 Current () 3.06/2.62 Required cooling ir flow (m 3 /h) ,83 0,89 17, ,84 0, ,84 0,93 40, ,85 0,94 50, * 0,85 0,94 60, * 0,86 0,95 67, * 0,87 0,95 81, * 0,89 0,96 100,7 54

55 MP / IP54-IP55 IP54 version, axial ventilation IP55 version, axial ventilation IP55 version, radial ventilation 55

56 MP 180-4B / IP54-IP55 Degree of Protection IP55 Cooling IC416 Rotor Inertia J (kgm 2 ) 0.74 Motor weight (kg) 460 n max () D-End Bearing** 3000 (4800)* 6216 Sound Pressure level (db()) at 50 N-End bearing Vibration Class Mounting IM1001*** Motor Nominal voltage (V) 400 Thermal Protection PTC 150 C * Can be increased on request ** bearing protection ring recommended above 100 ** *IM2001 for axial ventilation IP54 version, xial ventilation, Fan characteristics Voltage (V) 400/460 Mounting xial Speed () 2480/3050 Type of cooling fan Induced draught Power () 0.79/0.9 Current () 1.3/1.3 IP55 version, xial or radial ventilation, Fan characteristics (Voltage/frequency supply to precise in order) Speed () 2885/3462 Type of cooling fan Force draught Power () 1.5/1.5 Internal Static ir Pressure Drop (Pa) 900 Current () 3.06/2.62 Required cooling ir flow (m 3 /h) ,83 0,89 17, ,84 0,92 33, ,84 0,93 40, ,85 0,94 50, * 0,85 0,94 60, * 0,86 0,95 67, * 0,87 0, * 0,89 0,96 100,6 56

57 MP 180-4B / IP54-IP55 IP54 version, axial ventilation IP55 version, axial ventilation IP55 version, radial ventilation 57

58 MP 180-4C / IP54-IP55 Degree of Protection IP55 Cooling IC416 Rotor Inertia J (kgm 2 ) 0.94 Motor weight (kg) 550 n max () D-End Bearing** 3000 (4800)* 6216 Sound Pressure level (db()) at 50 N-End bearing Vibration Class Mounting IM1001*** Motor Nominal voltage (V) 400 Thermal Protection PTC 150 C * Can be increased on request ** bearing protection ring recommended above 100 ** *IM2001 for axial ventilation IP54 version, xial ventilation, Fan characteristics Voltage (V) 400/460 Mounting xial Speed () 2480/3050 Type of cooling fan Induced draught Power () 0.79/0.9 Current () 1.3/1.3 IP55 version, xial or radial ventilation, Fan characteristics (Voltage/frequency supply to precise in order) Speed () 2885/3462 Type of cooling fan Force draught Power () 1.5/1.5 Internal Static ir Pressure Drop (Pa) 900 Current () 3.06/2.62 Required cooling ir flow (m 3 /h) ,84 0,89 17, ,85 0,92 33, ,85 0,93 40, ,86 0,94 50, * 0,86 0,94 60, * 0,87 0,95 67, * 0,88 0,95 80, * 0,9 0,96 100,6 58

59 MP 180-4C / IP54-IP55 IP54 version, axial ventilation IP55 version, axial ventilation IP55 version, radial ventilation 59

60 MP / IP55 Degree of Protection IP55 Cooling IC416 Rotor Inertia J (kgm 2 ) 1.72 Motor weight (kg) 715 n max () 3800 Sound Pressure level (db()) at 50 D-End Bearing** ZC3 N-End bearing ZC3 Vibration Class Mounting IM1001 Motor Nominal voltage (V) 400 Thermal Protection PTC 150 C ** Bearing protection ring recommended above IP55 version, xial or radial ventilation, Fan characteristics (Voltage/frequency supply to precise in order) Speed () 2915/3498 Type of cooling fan Force draught Power () 3/3 Internal Static ir Pressure Drop (Pa) 1200 Current () 5.71/4.89 Required cooling ir flow (m 3 /h) ,83 0,9 17, ,84 0,93 33, ,84 0,94 40, ,85 0,95 50, ,85 0,95 60, ,86 0,96 67, ,87 0,96 80, ,89 0,97 100,5 60

61 MP / IP55 IP55 version, axial ventilation IP55 version, radial ventilation 61

62 MP 225-4B / IP55 Degree of Protection IP55 Cooling IC416 Rotor Inertia J (kgm 2 ) 2.29 Motor weight (kg) 870 n max () 3800 Sound Pressure level (db()) at 50 D-End Bearing** ZC3 N-End bearing ZC3 Vibration Class Mounting IM1001 Motor Nominal voltage (V) 400 Thermal Protection PTC 150 C ** Bearing protection ring recommended above IP55 version, xial or radial ventilation, Fan characteristics (Voltage/frequency supply to precise in order) Speed () 2915/3498 Type of cooling fan Force draught Power () 3/3 Internal Static ir Pressure Drop (Pa) 1200 Current () 5.71/4.89 Required cooling ir flow (m 3 /h) ,84 0,9 17, ,85 0,93 33, ,85 0,94 40, ,86 0,95 50, ,86 0,95 60, ,87 0,96 67, ,88 0,96 80, ,9 0,97 100,5 62

63 MP 225-4B / IP55 IP55 version, axial ventilation IP55 version, radial ventilation 63

64 MP 225-4C / IP55 Degree of Protection IP55 Cooling IC416 Rotor Inertia J (kgm 2 ) 2.55 Motor weight (kg) 930 n max () 3800 Sound Pressure level (db()) at 50 D-End Bearing** ZC3 N-End bearing ZC3 Vibration Class Mounting IM1001 Motor Nominal voltage (V) 400 Thermal Protection PTC 150 C ** Bearing protection ring recommended above IP55 version, xial or radial ventilation, Fan characteristics (Voltage/frequency supply to precise in order) Speed () 2915/3498 Type of cooling fan Force draught Power () 3/3 Internal Static ir Pressure Drop (Pa) 1200 Current () 5.71/4.89 Required cooling ir flow (m 3 /h) ,84 0,9 17, ,85 0,93 33, ,85 0,94 40, ,86 0,95 50, ,86 0,95 60, ,87 0,96 67, ,88 0,96 80, ,9 0,97 100,5 64

65 MP 225-4C / IP55 IP55 version, axial ventilation IP55 version, radial ventilation 65

66 MP / IP55 Degree of Protection IP55 Cooling IC416 Rotor Inertia J (kgm 2 ) 2.8 Motor weight (kg) 1110 n max () 3400 (4200)* Sound Pressure level (db()) at 50 D-End Bearing** 6222 C3 N-End bearing 6222 C3 Vibration Class Mounting IM1001 Motor Nominal voltage (V) 400 Thermal Protection PTC 150 C ** Bearing protection ring recommended above IP55 version, xial or radial ventilation, Fan characteristics (Voltage/frequency supply to precise in order) Speed () 2925/3510 Type of cooling fan Force draught Power () 5.5/7.5 Internal Static ir Pressure Drop (Pa) 2100 Current () 10.1/11.86 Required cooling ir flow (m 3 /h) ,84 0,86 16, ,84 0,91 33, ,84 0,93 40, ,85 0,95 50, ,85 0,95 60, ,85 0,96 67, * 0,85 0,96 80, * 0,86 0,

67 MP 250-4B / IP55 Degree of Protection IP55 Cooling IC416 Rotor Inertia J (kgm 2 ) 3.4 Motor weight (kg) 1280 n max () 3400 (4200)* Sound Pressure level (db()) at 50 D-End Bearing** 6222 C3 N-End bearing 6222 C3 Vibration Class Mounting IM1001 Motor Nominal voltage (V) 400 Thermal Protection PTC 150 C ** Bearing protection ring recommended above IP55 version, xial or radial ventilation, Fan characteristics (Voltage/frequency supply to precise in order) Speed () 2925/3510 Type of cooling fan Force draught Power () 5.5/7.5 Internal Static ir Pressure Drop (Pa) 2100 Current () 10.1/11.86 Required cooling ir flow (m 3 /h) ,84 0,86 16, ,84 0,91 33, ,84 0,93 40, ,85 0,95 50, ,85 0,95 60, ,85 0,96 67, * 0,85 0,96 80, * 0,86 0,

68 MP 250-4C / IP55 Degree of Protection IP55 Cooling IC416 Rotor Inertia J (kgm 2 ) 3.8 Motor weight (kg) 1410 n max () 3400 (3900)* Sound Pressure level (db()) at 50 D-End Bearing** 6222 C3 N-End bearing 6222 C3 Vibration Class Mounting IM1001 Motor Nominal voltage (V) 400 Thermal Protection PTC 150 C ** Bearing protection ring recommended above IP55 version, xial or radial ventilation, Fan characteristics (Voltage/frequency supply to precise in order) Speed () 2925/3510 Type of cooling fan Force draught Power () 5.5/7.5 Internal Static ir Pressure Drop (Pa) 2100 Current () 10.1/11.86 Required cooling ir flow (m 3 /h) ,84 0,86 16, ,84 0,91 33, ,84 0,93 40, ,85 0,95 50, ,85 0,95 60, ,85 0,96 67, * 0,85 0,96 80, * 0,86 0,

69 MP / IP55 Degree of Protection IP55 Cooling IC416 Rotor Inertia J (kgm 2 ) 4.17 Motor weight (kg) 1180 n max () 3200 (4000)* Sound Pressure level (db()) at 50 D-End Bearing** 6224 C3 N-End bearing 6224 C3 Vibration Class Mounting IM1001 Motor Nominal voltage (V) 400*** Thermal Protection PTC 150 C ** bearing protection ring recommended *** 690V possible on request Blower characteristics (Voltage/frequency supply to precise in order) Speed () 2925/3510 Type of cooling fan Force draught Power () 5.5/7.5 Internal Static ir Pressure Drop (Pa) 2600 Current () 10./11.86 Required cooling ir flow (m 3 /h) ,85 0,86 17, ,86 0,91 33, ,86 0,93 40, ,87 0,95 50, ,87 0,95 60, * 0,87 0,95 67,1 69

70 MP 280-4B / IP55 Degree of Protection IP55 Cooling IC416 Rotor Inertia J (kgm 2 ) 5.5 Motor weight (kg) 1530 n max () ** bearing protection ring recommended *** 690V possible on request 3200 (4000)* Blower characteristics (Voltage/frequency supply to precise in order) Sound Pressure level (db()) at 50 D-End Bearing** 6224 C3 N-End bearing 6224 C3 Vibration Class Mounting IM1001 Motor Nominal voltage (V) 400*** Thermal Protection PTC 150 C Speed () 2920/3510 Type of cooling fan Force draught Power () 5.5/7.5 Internal Static ir Pressure Drop (Pa) 2600 Current () 10.1/11.86 Required cooling ir flow (m 3 /h) ,87 0,87 17, ,88 0,92 33, ,88 0,94 40, ,88 0,96 50, ,88 0,96 60, * 0,88 0,96 67,1 70

71 MP 280-4C / IP55 Degree of Protection IP55 Cooling IC416 Rotor Inertia J (kgm 2 ) 6.2 Motor weight (kg) 1820 n max () 3200 (4000)* Sound Pressure level (db()) at 50 D-End Bearing** 6224 C3 N-End bearing 6224 C3 Vibration Class Mounting IM1001 Motor Nominal voltage (V) 400*** Thermal Protection PTC 150 C ** bearing protection ring recommended *** 690V possible on request Blower characteristics (Voltage/frequency supply to precise in order) Speed () 2920/3510 Type of cooling fan Force draught Power () 5.5/7.5 Internal Static ir Pressure Drop (Pa) 2600 Current () 10.1/11.86 Required cooling ir flow (m 3 /h) ,84 0,87 17, ,85 0,92 33, ,85 0,94 40, ,85 0,96 50, ,85 0,96 60, * 0,85 0,96 67,1 71

72 Ø Ø265 Ø Ø265 MP / IP55 Degree of Protection IP55 Cooling IC416 Rotor Inertia J (kgm 2 ) 12.9 Motor weight (kg) 2140 n max () ** bearing protection ring recommended *** 690V possible on request 3000 (3400)* Sound Pressure level (db()) at 50 D-End Bearing** 6228 C3 N-End bearing 6228 C3 Vibration Class Mounting IM1001 Motor Nominal voltage (V) 400*** Thermal Protection PTC 150 C Blower characteristics (Voltage/frequency supply to precise in order) Speed () 2925/3510 Type of cooling fan Force draught Power () 5.5/7.5 Internal Static ir Pressure Drop (Pa) 2600 Current () 10.1/11.86 Required cooling ir flow (m 3 /h) C ,85 0,86 17,1 DETIL ,86 0,91 33, ,86 0,93 40,3 160 C D DTE MODIFICTION NOM 1 21/04/2015 Mise en place nouvelle BàB M-E ,87 0,95 50, * 0,87 0,95 60, * 0,87 0,95 67, Ø Ø28 D DTE MODIFICTION NOM 1 21/04/2015 Mise en place nouvelle BàB M-E 1196 IC:06 IP: IM:1001 Pos: CDH/257 DETIL Encoder with cover C VIEW ,5 M30x Encoder with cover C VIEW ,5 M30x IC:06 IP:23 IM:1001 Pos: CDH/257 T-T Electric , Rue du 8 Mai PERSN Tél.: Fax : Dessiné MNESSE E

73 Ø Ø MP 315-4B / IP55 Degree of Protection IP55 Cooling IC416 Rotor Inertia J (kgm 2 ) 16.1 Motor weight (kg) 2560 n max () 3000 (3200)* Sound Pressure level (db()) at 50 D-End Bearing** 6228 C3 N-End bearing 6228 C3 Vibration Class Mounting IM1001 Motor Nominal voltage (V) 400*** Thermal Protection PTC 150 C ** bearing protection ring recommended *** 690V possible on request Blower characteristics (Voltage/frequency supply to precise in order) Speed () 2925/3510 Type of cooling fan Force draught Power () 5.5/7.5 Internal Static ir Pressure Drop (Pa) 2600 Current () 10.1/11.86 Required cooling ir flow (m 3 /h) D DTE MODIFICTION NOM 1 21/04/2015 Mise en place nouvelle BàB M-E ,87 0,87 DETIL 17, ,87 0,92 33, ,87 0, , C ,87 0,96 50, * 0,87 0,96 60, * 0,87 0,96 67,1 160 C D DTE MODIFICTION NOM 1 21/04/2015 Mise en place nouvelle BàB M-E DETIL 680 Ø Encoder with cover C VIEW ,5 M30x IC:06 IP:23 IM:1001 Pos: CDH/ Ø IC:06 IP:23 IM: Pos: CDH/257 Encoder with cover C VIEW T-T Electric 73 Dessiné Vérifié ,5 M30x3.5 MNESSE E BUMBC S , Rue du 8 Mai PERSN Tél.: Fax : DIMENSION DRWG 131

74 Ø Ø MP 315-4C / IP55 Degree of Protection IP55 Cooling IC416 Rotor Inertia J (kgm 2 ) Motor weight (kg) 2910 n max () * bearing protection ring recommended ** 690V possible on request 2600 Sound Pressure level (db()) at 50 D-End Bearing* 6228 C3 N-End bearing 6228 C3 Vibration Class Mounting IM1001 Motor Nominal voltage (V) 400** Thermal Protection PTC 150 C 85 Blower characteristics (Voltage/frequency supply to precise in order) Speed () 2925/3510 Type of cooling fan Force draught Power () 5.5/7.5 Internal Static ir Pressure Drop (Pa) 2600 Current () 10.1/11.86 Required cooling ir flow (m 3 /h) ,84 0, ,85 0,92 33, ,85 0,94 DETIL , ,86 0,96 50, ,86 0,96 60, ,86 0,96 67,1 C 1175 D DTE MODIFICTION NOM 1 21/04/2015 Mise en place nouvelle BàB M-E D DTE MODIFICTION NOM 1 21/04/2015 Mise en place nouvelle BàB M-E DETIL Encoder with cover M30x3.5 C Ø IC: IP:23 IM:1001 Pos: CDH/257 Encoder with cover ,5 M30x3.5 Ø C VIEW ,5 IC:06 IP:23 IM:1001 Pos: CDH/257 C VIEW 320 T-T Electric MP 315-4C 74 Dessiné MNESSE E Vérifié BUMBC S Norme 2768 pl , Rue du 8 Mai PERSN Tél.: Fax : DIMENSION DRWG 131

75 0 8, ,5 Ø Ø Ø75 MP / IP55 Degree of Protection IP55 Cooling IC416 Rotor Inertia J (kgm 2 ) Motor weight (kg) 2130 n max () 2800 (3000)* Sound Pressure level (db()) at 50 D-End Bearing** 6230 C3 N-End bearing 6230 C3 Vibration Class Mounting IM1001 Motor Nominal voltage (V) 400*** Thermal Protection PTC 150 C ** bearing protection ring recommended *** 690V possible on request Blower characteristics (Voltage/frequency supply to precise in order) Speed () 2925/3510 Type of cooling fan Force draught Power () 5.5/7.5 Internal Static ir Pressure Drop (Pa) 2600 Current () 10.1/11.86 Required cooling ir flow (m 3 /h) ,86 0, ,87 0,92 33, ,88 0,94 40, , ,96 50, * 200 0,88 0,96 60, * 0,88 0,96 66,9 532, C 250 D DTE MODIFICTION NOM 3 21/04/2015 Changement de BàB M- E , Ø28 D DTE 3 21/04/2015 Changem Encoder with cover DET D DTE MODIFICTION NOM 3 21/04/2015 Changement de BàB M- E VUE C , C C 200 VUE C Ø Ø Encoder with cover Encoder with cover DETIL 32 DETIL IC:06 IP:23 IM:1001 Pos: CDH/257 VUE C M30x3.5 M30x3.5 MP355-4 This document must not be copied without our written permission, and the contents should not be sent to a third party or used without our authorization. Contravention will be prosecuted T-T Electric Ce document ne doit pas être copié sans notre autorisation écrite, et son contenu ne peut pas être confié à un tiers ni Dessiné Vérifié Norme 2768 pl Masse ECHELLE 1/2 Ra in MNESSE E BUMBC S 22, Rue du 8 Mai PERSN Tél.: Fax : DIMENSION D PLN D'ENCOM FR

76 , , Ø Ø Ø75 MP 355-4B / IP55 Degree of Protection IP55 Cooling IC416 Rotor Inertia J (kgm 2 ) Motor weight (kg) 2830 n max () ** bearing protection ring recommended *** 690V possible on request 2800 (3000)* Sound Pressure level (db()) at 50 D-End Bearing** 6230 C3 N-End bearing 6230 C3 Vibration Class Mounting IM1001 Motor Nominal voltage (V) 400*** Thermal Protection PTC 150 C Blower characteristics (Voltage/frequency supply to precise in order) Speed () 2925/3510 Type of cooling fan Force draught Power () 5.5/7.5 Internal Static ir Pressure Drop (Pa) 2600 Current () 10.1/11.86 Required cooling ir flow (m 3 /h) ,85 0, ,86 0,92 33, , ,94 40, ,87 0,96 50, * 0,87 0,96 60, * 0,87 0,96 66,9 C , Encoder with cover D DTE 3 21/04/ , , D DTE MODIFICTION NOM 3 21/04/2015 Chandement de BàB M-E 250 D DTE MODIFICTION NOM 570 Ø /04/2015 Chandement de BàB M-E VUE C DET C 200 C Encoder with cover Encoder with cover M30x VUE C 570 Ø Ø VUE C DETIL DETIL IC:06 IP:23 IM:1001 Pos: CDH/257 M30x3.5 M30x MP355-4B This document must not be copied without our written permission, and the contents should not be sent to a third party or used without our authorization. Contravention will be prosecuted T-T Electric Ce document ne doit pas être copié sans notre autorisation écrite, Dessiné Vérifié Norme 2768 pl Masse ECHELLE 1/20 MNESSE E BUMBC S 22, Rue du 8 Mai PERSN Tél.: Fax : DIMENSION PLN D'ENCOM

77 , Ø Ø Ø75 MP 355-4C / IP55 Degree of Protection IP55 Cooling IC416 Rotor Inertia J (kgm 2 ) 25.7 Motor weight (kg) 3430 n max () 2800 (3000)* Sound Pressure level (db()) at 50 D-End Bearing** 6230 C3 N-End bearing 6230 C3 Vibration Class Mounting IM1001 Motor Nominal voltage (V) 400*** Thermal Protection PTC 150 C ** bearing protection ring recommended *** 690V possible on request Blower characteristics (Voltage/frequency supply to precise in order) Speed () 2925/3510 Type of cooling fan Force draught Power () 5.5/7.5 Internal Static ir Pressure Drop (Pa) 2600 Current () 10.1/11.86 Required cooling ir flow (m 3 /h) ,85 0,83 16, ,86 0,92 33, , ,94 40, ,87 0,96 50, * 200 0,87 0,96 60, * C 0,87 0,96 66,9 834, Encoder with cover D DTE 3 21/04/ , D DTE MODIFICTION NOM 670 Ø /04/2015 Chandement de 254 BàB M-E DE 834, D DTE MODIFICTION NOM 3 21/04/2015 Chandement de BàB M-E VUE C M30x3.5 C C Ø Ø Encoder with cover VUE CVUE C Encoder with cover M30x3.5 DETIL 32 DETIL M30x MP355-4C This document must not be copied without our written permission, and the contents should not be sent to a third party or used without our authorization. Contravention will be prosecuted T-T Electric Dessiné Vérifié Norme 2768 pl Masse MNESSE E BUMBC S IC:06 IP:23 IM:1001 Pos: CDH/257 22, Rue du 8 Mai PERSN Tél.: Fax : DIMENSION PLN D'ENCO

78 Ø75 Ø75 MP 355-4D / IP55 Degree of Protection IP55 Cooling IC416 Rotor Inertia J (kgm 2 ) Motor weight (kg) 4030 n max () 2700 Sound Pressure level (db()) at 50 D-End Bearing* 6230 C3 N-End bearing 6230 C3 Vibration Class Mounting IM1001 Motor Nominal voltage (V)** 400 Thermal Protection PTC 150 C * bearing protection ring recommended ** 690V possible on request 86 Blower characteristics (Voltage/frequency supply to precise in order) Speed () 2925/3510 Type of cooling fan Force draught Power () 5.5/7.5 Internal Static ir Pressure Drop (Pa) 2600 Current () 10.1/11.86 Required cooling ir flow (m 3 /h) ,85 0,83 16, ,86 0,92 33, ,86 0,94 40, ,87 0,96 50, ,87 0,96 60, ,87 0,96 66,9 C , D DTE M 3 21/04/2015 Chandemen Encoder with cover C C ,5 1064, D DTE MODIFICTION NOM 3 21/04/2015 Chandement de BàB M- E D DTE MODIFICTION NOM 3 21/04/2015 Chandement de BàB M- E Encoder with cover Encoder with cover 250 VUE C Ø Ø M30x3.5 DET Ø Ø28 VUE C VUE C M30x3.5 M30x DETIL 32 DETIL MP355-4D This document must not be copied without our written permission, and the contents should not be sent to a third party or used without our authorization. Contravention will be prosecuted T-T Electric Ce document ne doit pas être copié sans notre autorisation écrite, et son contenu ne peut pas être confié à un tiers ni utilisé sans notre accord.tout contrefacteur sera poursuivi. T-T Electric Dessiné Vérifié Norme Masse ECHELLE pl 1/20 Ra in microns 152,5 MNESSE E BUMBC S IC:06 IP:23 IM:1001 Pos: CDH/257 22, Rue du 8 Mai PERSN Tél.: Fax : DIMENSION DR PLN D'ENCOMB FR

79 79

80 Founded over 100 years ago, T-T Electric is a world-class supplier of top-quality industrial electric motors and drives. Pioneers in the industry, we are an experienced and established manufacturer of a comprehensive and cost-effective range of highly reliable drive products. They are used around the world in the toughest of application environments and in all industrial segments. Driven by customer demand, T-T Electric is continually researching product excellence and manufacturing process perfection. The flexible product design ensures easy adaptations to customer requirements. This, combined with unequalled short delivery times, make T-T Electric a reference within industry. Our extensive support services include diagnostics and maintenance on site as well as full overhaul in our own repair facilities. T-T Electric is committed to a working partnership with our customers. For mutual benefit, we focus on complete and innovative solutions together. Electric France 22 rue du 8 mai 1945 F PERSN Tel: +33 (0) Fax: +33 (0) info@t-telectric.fr UK T-T Electric Unit 7 Waterloo Park Upper Brook Street STOCKPORT SK1 3BP Tel: +44 (0) Fax: +44 (0) john.legg@t-telectric.com Germany T-T Electric Theodor-Stern-Kai Frankfurt Tel : +49 (0) Fax :+49 (0) info@t-telectric.com Russian Federation VIK-Industry B. Nizhegorodskaya Vladimir Tel : +7 (4922) Fax : +7 (4922) info@vecgroup.com US T-T Electric US PO Box Delafield, WI Phone # Fax # info@ttelectricusa.com Sweden Thrige Electric / Regal Lefflersgatan 1 S Uppsala Tel: +46 (0) Fax: +46 (0) info@regal.se China T-T Electric RM Jiafu Int'l Mansion 515 Ganjiang West Rd SUZHOU P.R. CH Tel: (+86512) Fax: (+86512) jacson@metals-star.com 80 nielsen@rbcn.dk

LARGE THREE-PHASE SQUIRREL CAGE ASYNCHRONOUS MOTORS FOR HEAVY DUTY APPLICATIONS ADH SERIES

LARGE THREE-PHASE SQUIRREL CAGE ASYNCHRONOUS MOTORS FOR HEAVY DUTY APPLICATIONS ADH SERIES LARGE THREE-PHASE SQUIRREL CAGE ASYNCHRONOUS MOTORS FOR HEAVY DUTY APPLICATIONS ADH SERIES FRAMES 355 560 355kW 1500kW (1500rpm) FOR INVERTER DUTY Code Declaration of conformity The motors described in

More information

Low Voltage Induction Motors

Low Voltage Induction Motors Low Voltage Induction Motors Catalogue-2009/04 E TAC-C CAST IRON Frame Size 71->355 0,18-315 kw t-telectric.com Technical features TAC-C motors are designed and manufactured according to IEC34, IEC72,

More information

CPLS Asynchronous motors for variable frequency. 95 Nm to 2900 Nm

CPLS Asynchronous motors for variable frequency. 95 Nm to 2900 Nm 95 Nm to 2900 Nm Introduction The range of IP23 protection CPLS asynchronous motors was designed for fixed and variable speed applications when there is little space available or (and) there is a wide

More information

AEEB AEVB LOW VOLTAGE SERIES Three-Phase Squirrel Cage Induction Motor Conforming to SS530 (Occasional Use) Conforming to IE1

AEEB AEVB LOW VOLTAGE SERIES Three-Phase Squirrel Cage Induction Motor Conforming to SS530 (Occasional Use) Conforming to IE1 AEEB AEVB LOW VOLTAGE SERIES Three-Phase Squirrel Cage Induction Motor Conforming to SS530 (Occasional Use) Conforming to IE1 STANDARD AND SPECIFICATION Performance: Meet the requirement of Singapore standard

More information

TYPE 2 poles 4 poles 6 poles 8 poles 2 / 4 poles 4 / 8 poles 2 / 8 poles 4 / 16 poles

TYPE 2 poles 4 poles 6 poles 8 poles 2 / 4 poles 4 / 8 poles 2 / 8 poles 4 / 16 poles BAH-BAHS series Overwiew MGM Electric Motors was established in 1950 as a brake motors manufacturer. MGM is today a world leading manufacturer of this line of products. MGM brake motors are designed and

More information

: B3; B5; B14; B34; B35; V1

: B3; B5; B14; B34; B35; V1 ATT WE series (Eff1) are 3-phase TEFC Cast-Iron high efficiency general purpose induction motors, which are designed to meet or exceed the requirements for energy efficiency such as: European Eff1, Australia

More information

ELECTRIC MOTORS. Selection. Starting torque and nominal torque

ELECTRIC MOTORS. Selection. Starting torque and nominal torque SELECTION PROCEDURE The output powers published overleaf are based upon continuous maximum rating conditions. Therefore design factors for above average running periods do not normally affect the selection.these

More information

A6C A5C-B6C B5C B5H A6C A5C B6C B5C B5H. Model. Up to kw. Power. Up to V. Voltages. Model IP55. Frame Pole 2, 4, 6, 8 and 10

A6C A5C-B6C B5C B5H A6C A5C B6C B5C B5H. Model. Up to kw. Power. Up to V. Voltages. Model IP55. Frame Pole 2, 4, 6, 8 and 10 A6C A5C-B6C B5C B5H Model Power Voltages Model IP55 A6C A5C B6C B5C B5H Up to 2.400 kw Up to 11.000 V LV A6C - B6C - A5C - B5C MV B5H Frame 71 560 Pole 2, 4, 6, 8 and 10 Cooling IC 411 ( IC 416 optional)

More information

SWE SERIES (IE3) WONDER ELECTRIC MOTOR (S) PTE LTD. Energy Saving Low Noise Environmental Friendly IEC Dimension Low Vibration European Design

SWE SERIES (IE3) WONDER ELECTRIC MOTOR (S) PTE LTD. Energy Saving Low Noise Environmental Friendly IEC Dimension Low Vibration European Design RANGE OF PRODUCTS Three phase asynchronous squirrel-cage & slip ring induction motors Three phase asynchronous self-braking motors Hollow shaft rotor motors Cooling tower motors High motors, (IE2) (IE3)

More information

General Purpose Cast Iron Motors

General Purpose Cast Iron Motors General Purpose Cast Iron Motors Totally enclosed squirrel cage three phase low voltage motors, Sizes 71-355, 0.25 to 250 kw www.abb.com/motors&drives > Motors > Low voltage motors > General purpose motors

More information

1LG0 Low-voltage Motors

1LG0 Low-voltage Motors Low-voltage motors up to 315kW Catalog D81.5.1 1LG Low-voltage Motors Answers for industry. 1 Table of Contents Overview 3 Motor standards 5 Mechanical design 6 Electrical design 1 Converter fed application

More information

General Purpose Energy Efficient Induction Motors series 2SIE

General Purpose Energy Efficient Induction Motors series 2SIE General Purpose Energy Efficient Induction Motors series 2SIE Comply with the new efficiency classes for low-voltage three-phase motors IEC 60034-30 standard and EU Regulation 640/2009 Product Catalogue

More information

champion series motors

champion series motors Introducing A brand new series of Super Performers Data Sheet champion series motors FRAME SIZE 63-132M TEFC 3 Phase Squirrel Cage Induction Motors Siemens CHAMPION Series Cage Motors are suitable for

More information

Ordering information. When placing an order, specify motor type, size and product code according to the following example.

Ordering information. When placing an order, specify motor type, size and product code according to the following example. Ordering information When placing an order, specify motor type, size and product code according to the following example. Example Motor type M3AA 112 MB Pole number 4 Mounting arrangement (IM-code) IM

More information

THREE PHASE ASYNCHRONOUS MOTORS. MS/S Series (frame Aluminum) TC Series (frame Cast iron) Y Series (frame Cast iron)

THREE PHASE ASYNCHRONOUS MOTORS. MS/S Series (frame Aluminum) TC Series (frame Cast iron) Y Series (frame Cast iron) THREE PHASE ASYNCHRONOUS MOTORS MS/S Series (frame 56-200 Aluminum) TC Series (frame 160-355 Cast iron) Y Series (frame 132-355 Cast iron) INDICE 01. General features p.03 02. Standards p.04 03. Mounting

More information

ELECTRIC MOTORS 3SIE IE3

ELECTRIC MOTORS 3SIE IE3 EECTRIC MOTORS 3SIE IE3 TECHNIC INFORMTION TYE 3SIE IE3 Construction 3SIE have a stator house in aluminum from frame 80-112. End shields are in aluminum in frame 80-100 and in cast iron from frame 112.

More information

DC motors. G-motion. CTi Automation - Phone: Fax: Web:

DC motors. G-motion. CTi Automation - Phone: Fax: Web: G-motion No matter which drive solution you imagine, we make your dreams come true. True to our slogan (one stop shopping) we offer you a complete programme of electronic and mechanical drive systems which

More information

FCR asynchronous brake motors LS FCR. General information

FCR asynchronous brake motors LS FCR. General information General information LIFTING USE : U.L. Enclosed three-phase asynchronous brake motors, LS series with failsafe brake, according to IEC 34, 72, EN 50281. Single speed : 0.55 to 15, frame size from 80 to

More information

KAT.NMST ENG NORM ELECTRIC MOTORS THREE PHASES SQUIRREL CAGE TEFC NMST

KAT.NMST ENG NORM ELECTRIC MOTORS THREE PHASES SQUIRREL CAGE TEFC NMST KAT.NMST.02.14.ENG NORM ELECTRIC MOTORS THREE PHASES SQUIRREL CAGE TEFC NMST 90 355 IMPORTANT NOTE: Due to the continious development policy, our companyreserves the right to make changes the values, dimensions

More information

From 16 June 2011, motors placed for the first-time on the market shall have a minimum efficiency class of IE2.

From 16 June 2011, motors placed for the first-time on the market shall have a minimum efficiency class of IE2. INTRODUCTION New efficiency classes for the low-voltage three-phase motors (IE = International Efficiency). Along with the international discussion on energy efficiency a worldwide harmonized energy efficiency

More information

Energy Saving Three Phase Motors

Energy Saving Three Phase Motors e-drive Energy Saving Three Phase Motors IEC frames 56 to 400 Outputs 0.09 to 630 IE2 MEPS2006 Type: AHE Aluminium Motors Type: HE Cast-Iron Motors 1 When you need all the features of a premium quality

More information

Open continuous current (DC) motors MS 1 - MS 2. General information

Open continuous current (DC) motors MS 1 - MS 2. General information MS 1 - MS 2 General information Open continuous current (dc) motors conforming to the IEC specifications. MS 1 : - frame size 80 to 132 mm, - power 0.44 to 8.85 kw. MS 2 : - frame size 112 and 132 mm,

More information

CONTENTS 1 GENERAL 2 STANDARDS. 3 TECHNICAL FEATURES 3.1 Basic Technical Data 3.2 Standard Accessories 3.3 Tolerances

CONTENTS 1 GENERAL 2 STANDARDS. 3 TECHNICAL FEATURES 3.1 Basic Technical Data 3.2 Standard Accessories 3.3 Tolerances CONTENTS 1 GENERAL 2 STANDARDS 3 TECHNICAL FEATURES 3.1 Basic Technical Data 3.2 Standard Accessories 3.3 Tolerances 4 MOTOR DESIGN 4.1 Stator Casing 4.2 Stator Core with Winding 4.3 Stator Winding 4.4

More information

CONTENTS 1 GENERAL 2 STANDARDS. 3 TECHNICAL FEATURES 3.1 Basic Design Data 3.2 Standard Accessories 3.3 Tolerances

CONTENTS 1 GENERAL 2 STANDARDS. 3 TECHNICAL FEATURES 3.1 Basic Design Data 3.2 Standard Accessories 3.3 Tolerances CONTENTS 1 GENERAL 2 STANDARDS 3 TECHNICAL FEATURES 3.1 Basic Design Data 3.2 Standard Accessories 3.3 Tolerances 4 MOTOR DESIGN 4.1 Stator Casing 4.2 Stator Core with Winding 4.3 Stator Winding and Insulation

More information

FAP asynchronous brake motors LS FAP. General information

FAP asynchronous brake motors LS FAP. General information General information GENERL USE : U.G. Enclosed three-phase asynchronous brake motor, series LS with failsafe alternating current (ac) brake, according to IEC 60034,60072, EN50281. Separate supply to the

More information

Series E4F E5F

Series E4F E5F Three Phase Induction Motors With Rotors Wound for Hoists Series E4F 160-315 E5F 355-400 ASI NT 003.1 I N D E X Use 2 Electrical Tolerances 9 Mechanical Tolerances 9 General Characteristics 2 Technical

More information

FLSD (E) Atmospheres containing explosive GAS totally enclosed three-phase asynchronous motors General information

FLSD (E) Atmospheres containing explosive GAS totally enclosed three-phase asynchronous motors General information (E) Atmospheres containing explosive GAS General information Flameproof totally enclosed three-phase asynchronous motors, FLSD (E) series, according to IEC 60034, 60038, 60072, 60079-0 and 60079-1, EN

More information

Low-voltage motors up to 315kW. 1LG0 Low-voltage Motors. Answers for industry.

Low-voltage motors up to 315kW. 1LG0 Low-voltage Motors. Answers for industry. Low-voltage motors up to 315kW 1LG0 Low-voltage Motors Answers for industry. 1 Low-voltage squirrel-cage motors 4 Motor standard 4 Standard 5 Condition 5 Mechanical design 5 High quality performance 5

More information

Technical Documentation

Technical Documentation Technical Documentation LOW VOLTAGE THREE PHASE TEFC CAGE MOTORS IE315EN Mission, Vision, Targets Our electric motors and generators are optimized in accordance with our client's technical and economical

More information

CENTRIFLOW 3D WITH EC MOTOR >> Technical catalogue

CENTRIFLOW 3D WITH EC MOTOR >> Technical catalogue CENTRIFLOW 3D Plug Fan WITH EC MOTOR >> Technical catalogue air comfort CentriFlow 3D 2 GMEC CentriFlow 3D - Technical Catalogue Contents GENERL Description and survey chart pplication... 3 General Survey

More information

Variable speed asynchronous motors with FCR brake LSMV FCR. General information

Variable speed asynchronous motors with FCR brake LSMV FCR. General information General information GENERAL USE : U.G. Closed three-phase asynchronous brake motors, LSMV series with failsafe continuous (dc) brake, according to IEC 3, 72, EN 50281. Single speed : 0.25 to 11, frame

More information

IP66 GSW GEAR BOX MOTOR SERIES

IP66 GSW GEAR BOX MOTOR SERIES IP66 GSW GEAR BOX MOTOR SERIES Three Phase Aluminium Gear Box Motors Australian Version October 2013 CONTENTS INTRODUCTION Pg 3 MATERIALS AND CONSTRUCTION Pg 3-4 SERIES OVERVIEW Pg 5 PERFORMANCE DATA Pg

More information

Technical Documentation

Technical Documentation Technical Documentation LOW VOLTAGE THREE PHASE TEFC CAGE MOTORS IE316EN Mission, Vision, Targets Our electric motors and generators are optimized in accordance with our client's technical and economical

More information

Non-Standard Motors Overview. Low-Voltage. IEC Squirrel-Cage Motors Frame sizes 315 to 450 Power range 160 kw to 1250 kw

Non-Standard Motors Overview. Low-Voltage. IEC Squirrel-Cage Motors Frame sizes 315 to 450 Power range 160 kw to 1250 kw Non-Standard Motors Overview MOTORS Low-Voltage IEC Squirrel-Cage Motors Frame sizes 15 to 450 Power range 160 kw to 1250 kw Non-standard motors frame size 15 and above Overview N compact three-phase asynchronous

More information

MOUNTING & MAINTENANCE INSTRUCTIONS FOR

MOUNTING & MAINTENANCE INSTRUCTIONS FOR 9 Pages / Page 1 MOUNTING & MAINTENANCE INSTRUCTIONS FOR THREEPHASE INDUCTION MOTORS - TYPES DM1 / DMA1 / DMA2 TABLE OF CONTENTS page 1 General information 2 2 Delivery 2 3 Mounting 2 4 Coupling 2 4.1.

More information

ASM. Asynchronous Spindle. SEM Limited Faraday Way Orpington, Kent BR5 3QT United Kingdom

ASM. Asynchronous Spindle. SEM Limited Faraday Way Orpington, Kent BR5 3QT United Kingdom NE ASM Asynchronous Spindle Motors SEM Limited Faraday Way Orpington, Kent BR 3QT United Kingdom Tel: +44 ()1689 8847 Fax: +44 ()1689 884884 Email: sales@sem.co.uk Web: www.sem.co.uk Version 2.1 June 211

More information

SINGLE PHASE TEFC CAGE MOTORS

SINGLE PHASE TEFC CAGE MOTORS SINGLE PHASE TEFC CAGE MOTORS 2 SINGLE PHASE TEF CAGE MOTORS Mechanical protection: IP 54 Voltage: 220 V, 50 Hz Type Output power P N kw Rated speed n N min -1 Efficiency % Power factor cos Rated current

More information

Three-phase roller table motors with squirrel-cage rotor for the application at the frequency converters Series A21O, A20O, ARB, ARC.

Three-phase roller table motors with squirrel-cage rotor for the application at the frequency converters Series A21O, A20O, ARB, ARC. Three-phase roller table motors with squirrel-cage rotor for the application at the frequency converters Series A21O, A20O, ARB, ARC Product summary VEM motors GmbH Introduction Roller table motors are

More information

Squirrel Cage Induction Motors MA - A4 - BB - B4 - B5 SERIES SIZES. MarelliMotori ASI.CT.033.2

Squirrel Cage Induction Motors MA - A4 - BB - B4 - B5 SERIES SIZES. MarelliMotori ASI.CT.033.2 Marine Motors Three Phase Squirrel Cage Induction Motors MA - A4 - BB - B4 - B5 SERIES 63-400 SIZES MarelliMotori ASI.CT.033.2 CONTENTS Page STANDARDS 5 ESSENTIAL AND NON-ESSENTIAL SERVICE 5 CLASSIFICATION

More information

Permanent-magnet synchronous motors

Permanent-magnet synchronous motors Permanent-magnet synchronous motors Contents Product description 12/2 Overview of technical data 12/4 Motor selection data Series PE.. for Super Premium Efficiency IE4 1) 12/5 Series P, high-power motors

More information

OM DC Motors Series. Ⅱ. Item Define Example:

OM DC Motors Series. Ⅱ. Item Define Example: OM DC Motors Series Ⅰ.Features and Uses OM DC motors Series are new developed products. The products have found wide use for prime mover in various machinery, such as mill auxiliary in metallurgical industry,

More information

ELK PRODUCT CATALOGUE. elkmotor.com.tr

ELK PRODUCT CATALOGUE. elkmotor.com.tr ELK 0501-0418 PRODUCT CATALOGUE elkmotor.com.tr THREE PHASE SQUIRREL CAGE ASYNCHRONOUS MOTORS ELK Motor has been founded by major shareholders of Yılmaz Reduktor, as a continuation of the product family.

More information

LSPXMV FCR Atmospheres containing explosive dust FCR asynchronous brake motors. General information

LSPXMV FCR Atmospheres containing explosive dust FCR asynchronous brake motors. General information General information GENERAL USE : U.G. Enclosed three-phase brake asynchronous motors, LSPXMV series with failsafe brake, according to IEC 6003, 60072, EN 50281. Single speed : 0.25 to 11, frame size from

More information

Cast Iron Frame Motors For Zone 21 Improved Efficiency EFF2

Cast Iron Frame Motors For Zone 21 Improved Efficiency EFF2 Motors Energy Automation Coatings Cast Iron Frame Motors For Zone 21 Improved Efficiency EFF2 Standard Features: Three-phase, multivoltage, IP66, TEFC : 0.12 up to 250kW Frames: 63 up to 355M/L Voltage:

More information

Axial-flow Fan AFC. Model numbering system AF C / T. Accessories Three phase. Power rate 1.

Axial-flow Fan AFC. Model numbering system AF C / T. Accessories Three phase. Power rate 1. xial-flow Fan FC Construction xial fan designed for installation in a ducted system. Casing of rolled and electro-welded steel sheet, powder coated RL5. Impeller in polypropylene. Casing in acid-proof

More information

Standardmotoren Standard motors

Standardmotoren Standard motors Standardmotoren Standard motors Contents Product description 2/2 Overview of technical data 2/5 2 Series W4.R for Premium Efficiency IE3 2/6 Series WE.R for High Efficiency IE2 2/14 Series K2.R for Standard

More information

Catalog Mars Low voltage Brake motors

Catalog Mars Low voltage Brake motors Catalog Mars 2014 Low voltage Brake motors We provide motors, generators and mechanical power transmission products, services and expertise to save energy and improve customers processes over the total

More information

Three-phase asynchronous motors for low voltage with squirrel-cage rotor. with EU efficiency classification

Three-phase asynchronous motors for low voltage with squirrel-cage rotor. with EU efficiency classification Three-phase asynchronous motors for low voltage with squirrel-cage rotor with EU efficiency classification Contents Page Introduction 3 Standards and regulations 4 Efficiency 5 Bearings / Bearing lubrication

More information

INTER PLANT STANDARD STEEL INDUSTRY. SPECIFICATION FOR GENERAL PURPOSE SQUIRREL CAGE INDUCTION MOTORS (Fifth Revision) BASED ON IS 325:1996

INTER PLANT STANDARD STEEL INDUSTRY. SPECIFICATION FOR GENERAL PURPOSE SQUIRREL CAGE INDUCTION MOTORS (Fifth Revision) BASED ON IS 325:1996 INTER PLANT STANDARD STEEL INDUSTRY IPSS SPECIFICATION FOR GENERAL PURPOSE SQUIRREL CAGE INDUCTION MOTORS (Fifth Revision) BASED ON IS 325:1996 IPSS: 1-03-001-14 Formerly: IPSS:1-03-001-05 0. FOREWORD

More information

Teepak Totally Enclosed Tube Ventilated High Voltage Induction Motors. A Regal Brand.

Teepak Totally Enclosed Tube Ventilated High Voltage Induction Motors. A Regal Brand. Teepak Totally Enclosed Tube Ventilated High Voltage Induction Motors A Regal Brand www.regalbeloit.com Specifications Range Poles Voltage : Upto 3000 KW : Upto 14 Pole : Upto 11000 Volt Frame : 450 1000

More information

Data Sheet PM Generator Kit version K535S-4-11 K535S-4-12 K535S-4-14 K535S-4-17 K535S-4-22

Data Sheet PM Generator Kit version K535S-4-11 K535S-4-12 K535S-4-14 K535S-4-17 K535S-4-22 Data Sheet PM Generator Kit version -11-12 -14-17 -22 HIGH THERMAL CLASS HIGH EFFICIENCY RELIABILITY DESIGNED AND MANUFACTURED IN FRANCE OPTIMISED INTEGRATION HIGH QUALITY SAMARIUM COBALT MAGNETS This

More information

1. SPECIFICATION. Altitude of motor installation. Information: Resistance and temperature specifications of the PTC thermistor / posistor/.

1. SPECIFICATION. Altitude of motor installation. Information: Resistance and temperature specifications of the PTC thermistor / posistor/. 1. SPECIFICATION 5 GENERAL INFORMATION Motors with parameters according to the data sheet comply with the requirements of the IEC 60034-1 standard, and IEC 60034-30 class efficiency IE2 Motor versions:

More information

THREE-PHASE ASYNCHRONOUS MOTORS EFFICIENCY CLASS ACCORDING IEC

THREE-PHASE ASYNCHRONOUS MOTORS EFFICIENCY CLASS ACCORDING IEC THREE-PHASE ASYNCHRONOUS MOTORS EFFICIENCY CLASS ACCORDING IEC 60034-30 1st EDITION IE1/IE2-MS IE1/IE2-EG Series IE1 Standard efficiency IE2 High efficiency THREE-PHASE ASYNCHRONOUS MOTORS EFFICIENCY CLASS

More information

INTER PLANT STANDARD STEEL INDUSTRY. Corresponding IS does not exist

INTER PLANT STANDARD STEEL INDUSTRY. Corresponding IS does not exist INTER PLANT STANDARD STEEL INDUSTRY IPSS SPECIFICATION FOR ac ROLLER TABLE MOTORS (Second Revision) Corresponding IS does not exist IPSS:1-03-007-14 Formerly : IPSS:1-03-007-03 0. FOREWORD 0.1 This Inter

More information

Three-phase asynchronous motors

Three-phase asynchronous motors Three-phase asynchronous motors for low voltage with squirrel-cage rotor Product specification Series K11R, K21R and K22R Introduction Standards and regulations Progressive correspondence between output

More information

LSES high efficiency three-phase asynchronous motors. General information

LSES high efficiency three-phase asynchronous motors. General information Efficiency class IE2 General information Totally enclosed three-phase saving asynchronous motors, series, according to IEC 60034, 60038, 60072 ; 0.75 to 200 kw, frame size 80 to 315 mm. Single speed: 2,4

More information

Datasheet. Pitch Motor PMSM SP190C8

Datasheet. Pitch Motor PMSM SP190C8 Pitch Motor PMSM SP190C8 Permanent Magnet Compact and light weight High peak torque Excellent efficiency Maintenance free, No fan 5 year warranty Document no.: 4121260007a 1 Application The Pitch motor

More information

From 4 to 20 poles ( over contact MM) IP 23. Available up to IP 44 with filters.

From 4 to 20 poles ( over contact MM) IP 23. Available up to IP 44 with filters. MJT Model Power Voltages MJT Up to 5.200 kva Up to 1.000 V Frame 160 ± 900 Pole From 4 to 20 poles ( over contact MM) Cooling IC 01 IP Enclosure Main Applications Sector IP 23. Available up to IP 44 with

More information

General Specifications. Cooling Method 3M series are IC 411 Standard. IC 416, IC 418 can be provided Upon request

General Specifications. Cooling Method 3M series are IC 411 Standard. IC 416, IC 418 can be provided Upon request 3M SERIES Three Phases Low Voltage Asynchronous Motors 3M Series Vilma motors are designed and manufactured with high quality materials and workmanship in order to meet demanding and arduous operation

More information

GMP-Type. Key Features: Integrated Motor-Pump Units

GMP-Type. Key Features: Integrated Motor-Pump Units Integrated Motor-Pump Units GMP-Type Key Features: Direct coupling between motor and pump Rotation: Right (viewed from shaft end) Electric motor mounting type: special B3-B14 (IEC 34-7) Rated Voltage:

More information

Datasheet. Pitch Motor PMSM SP190F8

Datasheet. Pitch Motor PMSM SP190F8 Pitch Motor PMSM SP190F8 Permanent Magnet Compact and light weight High peak torque Excellent efficiency Maintenance free, No fan 5 year warranty Document no.: 4121260009c 1 Application The Pitch motor

More information

ECO-TOP POWER. GENERAL CATALOGUE english. electric motors. rev. 20

ECO-TOP POWER. GENERAL CATALOGUE english. electric motors. rev. 20 ECO-TOP POWER electric motors GENERAL CATALOGUE english rev. 20 electric motors warehouse sm 5120 1 3 warehouse sm 4720 warehouse sm 730 2 THE LARGEST JUST IN TIME STOCK IN EUROPE A GREAT VALUE CREATING

More information

Variable speed asynchronous motors with FCPL brake LSMV FCPL. General information

Variable speed asynchronous motors with FCPL brake LSMV FCPL. General information General information GENERAL USE : U.G. Enclosed three-phase asynchronous brake motors, LSMV series with failsafe continuous current (dc) brake, according to IEC 60034, 60072, EN50281. Separate mains supply

More information

THREE PHASE ASYNCHRONOUS MOTORS WITH SQUIRREL CAGE

THREE PHASE ASYNCHRONOUS MOTORS WITH SQUIRREL CAGE CAG Electric Machinery HGLIE2 series THREE PHASE ASYNCHRONOUS MOTORS WITH SQUIRREL CAGE Introduction Motors HGL IE2 with cast iron frame offers increased power output with reduced power consumption. This

More information

PLS Open Drip Proof three-phase asynchronous motors. General information

PLS Open Drip Proof three-phase asynchronous motors. General information General information Open Drip Proof three-phase asynchronous motors, series PLS, according to IEC 60034, 60066, 60072 power 7,5 kw to 900 kw, frame size 160 to 400 mm, 2, 4, 6 and 8 ; 230/400 V or 400

More information

E280 DIAMETER FRAMES

E280 DIAMETER FRAMES E28 DIAMETER FRAMES MODEL NUMBER CODE...E28 FRAME To construct a motor listing, select the combination of features required, and put all the coded information in the proper sequence. Please account for

More information

39. Three-Phase Asynchronous single speed motors p.70

39. Three-Phase Asynchronous single speed motors p.70 INDex 01. General features p.08 02. Standards p.09 03. Mounting and positions p.10 04. Ingress protection p.11 05. General costruction features p.11 06. Cooling p.12 07. Bearings p.13 08. Terminal box

More information

MJH. Model. Up to kva. Power. Up to V. Voltages. Frame 400 ± Pole 4, 6, 8. (over contact MM) Cooling IC 01

MJH. Model. Up to kva. Power. Up to V. Voltages. Frame 400 ± Pole 4, 6, 8. (over contact MM) Cooling IC 01 MJH Model Power Voltages MJH Up to 12.500 kva Up to 15.000 V Frame 400 ± 1.250 Pole 4, 6, 8 Cooling IC 01 (over contact MM) IP Enclosure Main Applications Sector IP 23. Available up to IP 44 with filters.

More information

ODP SERIES PREMIUM INDUSTRIAL OPEN DRIP PROOF MOTORS C280M to C355LB Frame. Australian Version October 2013

ODP SERIES PREMIUM INDUSTRIAL OPEN DRIP PROOF MOTORS C280M to C355LB Frame. Australian Version October 2013 ODP SERIES PREMIUM INDUSTRIAL OPEN DRIP PROOF MOTORS C280M to C355LB Frame Australian Version October 2013 ODP SERIES (OPEN DRIP PROOF) PREMIUM INDUSTRIAL OPEN DRIP PROOF MOTORS, C280M TO C355LB FRAME

More information

Asynchronous, Low Voltage, Squirrel Cage, Three Phase Electric Motors

Asynchronous, Low Voltage, Squirrel Cage, Three Phase Electric Motors Asynchronous, Low Voltage, Squirrel Cage, Three Phase Electric Motors Series R2, Frame 63 355 Introduction KHM R2 series cast iron motors are totally enclosed fan cooled, 3 phase, and squirrel cage induction

More information

E180 DIAMETER FRAMES

E180 DIAMETER FRAMES E18 DIAMETER FRAMES MODEL NUMBER CODE...E18 FRAME To construct a motor listing, select the combination of features required and put all the coded information in the proper sequence. Please account for

More information

MJB. Model. Up to kva. Power. Up to V. Voltages. Frame 160 ± 900. Pole 4, 6, 8, 10 and 12. (over contact MM) Cooling IC 01

MJB. Model. Up to kva. Power. Up to V. Voltages. Frame 160 ± 900. Pole 4, 6, 8, 10 and 12. (over contact MM) Cooling IC 01 MJB Model Power Voltages MJB Up to 6.500 kva Up to 1.000 V Frame 160 ± 900 Pole 4, 6, 8, 10 and 12 Cooling IC 01 (over contact MM) IP Enclosure Main Applications Sector IP 23. Available up to IP 44 with

More information

Catalog. Low voltage General performance IE3 efficiency cast iron motors

Catalog. Low voltage General performance IE3 efficiency cast iron motors Catalog Low voltage General performance IE3 efficiency cast iron motors ABB Motors and Generators I Low voltage general performance IE3 efficiency motors 2 General performance IE3 efficiency cast iron

More information

ECO-TOP POWER. GENERAL CATALOGUE english. electric motors. rev. 21

ECO-TOP POWER. GENERAL CATALOGUE english. electric motors. rev. 21 ECO-TOP POWER electric motors GENERAL CATALOGUE english rev. 21 electric motors warehouse sm 5120 1 3 warehouse sm 4720 warehouse sm 730 2 THE LARGEST JUST IN TIME STOCK IN EUROPE A GREAT VALUE CREATING

More information

DYNEO VARIABLE SPEED DRIVES Unidrive SP variable speed drives LSRPM - PLSRPM permanent magnet synchronous motors

DYNEO VARIABLE SPEED DRIVES Unidrive SP variable speed drives LSRPM - PLSRPM permanent magnet synchronous motors Unidrive SP variable speed drives LSRPM - PLSRPM permanent magnet 0.75 kw to 400 kw Technical catalogue 4936 en - 2012.10 / b Rectifier Simplicity Performance Install and start using your system quickly

More information

Low Voltage General Purpose Motors

Low Voltage General Purpose Motors Low Voltage General Purpose Motors Making you more competitive ABB s General purpose motor is designed for use in general industry, meeting the demands of standard applications for OEM's. Motors are readily

More information

Lenze. Drives with worm gearboxes 52.

Lenze. Drives with worm gearboxes 52. 6 887 Lenze Drives with worm gearboxes 5. Lenze Drive Systems GmbH, Postfach 0 5, D-76 Hameln, Site: Groß Berkel, Hans-Lenze-Straße, D-855 Aerzen, Phone ++9 (0) 55 8-0, Telefax ++9 (0) 55 8- E-Mail: Lenze@Lenze.de

More information

Datasheet. Pitch Motor PMSM SP260B8

Datasheet. Pitch Motor PMSM SP260B8 Pitch Motor PMSM SP260B8 Permanent Magnet Compact and light weight High peak torque Excellent efficiency Maintenance free, No fan 5 year warranty Document no.: 4121260012a 1 Application The Pitch motor

More information

ASYNCHRONOUS MOTORS THREE-PHASE MOTORS SINGLE-PHASE MOTORS BRAKE MOTORS INSTRUCCIONES DE SERVICIO OPERATING INSTRUCTIONS 2016

ASYNCHRONOUS MOTORS THREE-PHASE MOTORS SINGLE-PHASE MOTORS BRAKE MOTORS INSTRUCCIONES DE SERVICIO OPERATING INSTRUCTIONS 2016 ASYNCHRONOUS INSTRUCCIONES DE SERVICIO MOTORS THREE-PHASE MOTORS SINGLE-PHASE MOTORS BRAKE MOTORS OPERATING INSTRUCTIONS 2016 3006/16 en Ed.02.2016 Read these Operating Instructions before you transport,

More information

LSES high efficiency three-phase asynchronous motors General information

LSES high efficiency three-phase asynchronous motors General information General information Efficiency class IE2 Totally enclosed three-phase powersaving asynchronous motors, LSES series, according to IEC 60034, 60038, 60072 ; power 0.75 to 200 kw, frame size 80 to 315 mm.

More information

Standard cast iron Motor

Standard cast iron Motor Standard cast iron Motor Frame size 80 to 355 Série 1L Phase 3 Voltage 265/460V 60Hz Types of mounting B3 V9 B5 B14 B6 B9 B3 / B5 V5 B3 / B14 B15 V1 B7 V18 V1 / V5 V8 V18 / V5 V6 B8 V3 / V6 V3 V19 V19

More information

Catalog October 2014 Low voltage General performance motors according to EU MEPS

Catalog October 2014 Low voltage General performance motors according to EU MEPS Catalog October 2014 Low voltage General performance motors according to EU MEPS With expertise, and a comprehensive portfolio of products and life-cycle services, we help value-minded industrial customers

More information

Demag KB conical-rotor brake motors. Drives with unique principle

Demag KB conical-rotor brake motors. Drives with unique principle Demag KB conical-rotor brake motors Drives with unique principle 37468 Demag KB conical rotor brake motors: Demag KB conical rotor brake motors offered by Demag Cranes & Components feature a unique principle:

More information

Low Voltage General Purpose Motors

Low Voltage General Purpose Motors Low Voltage General Purpose Motors Making you more competitive ABB s General purpose motor is designed for use in general industry, meeting the demands of standard applications for OEM's. Motors are readily

More information

SERIES PR90H PROGRAMMABLE INCREMENTAL HOLLOW SHAFT ENCODER FOR INDUSTRIAL APPLICATIONS REFERENCE PR90H - C C - C. External diameter 58 mm

SERIES PR90H PROGRAMMABLE INCREMENTAL HOLLOW SHAFT ENCODER FOR INDUSTRIAL APPLICATIONS REFERENCE PR90H - C C - C. External diameter 58 mm PROGRAMMABLE INCREMENTAL HOLLOW SHAFT ENCODER FOR INDUSTRIAL APPLICATIONS Programmable incremental optical encoder from 1 to 65.536 pulses per rotation Programmable via USB, without an additional programming

More information

Brake Motors Aluminium Frame Improved Efficiency EFF2

Brake Motors Aluminium Frame Improved Efficiency EFF2 Motors Energy Automation Coatings Brake Motors Aluminium Frame Improved Efficiency EFF2 Standard Features: Three-phase, multivoltage, IP55, TEFC Output: 0.12 up to 11kW Frames: 63 up to 132M Voltage: 220-240/380-415V

More information

Asynchronous and synchronous motors for SINAMICS S120 1PL6 asynchronous motors Forced ventilation, IP23 degree of protection

Asynchronous and synchronous motors for SINAMICS S120 1PL6 asynchronous motors Forced ventilation, IP23 degree of protection Overview 1PL6 motors, shaft heights 180 to 22 Benefits 7 Extremely high power density with small motor dimensions (0 to 60 % higher output as compared to 1PH7 in degree of protection IP) 7 Speed down to

More information

W22 Medium Voltage Motors TEFC - Severe Duty

W22 Medium Voltage Motors TEFC - Severe Duty 101 www.pamensky.com W22 Medium Voltage Motors TEFC - Severe Duty Standard Features Three-phase, 2, 4, 6 and 8 pole, 60Hz Voltage: 1200V, 2300V, 2400V, 3300V, 4000V, 4160V & 6600V Totally Enclosed Fan

More information

AESV / AESU / AESV-LA Series Squirrel Cage Induction Motor AESV1S / AESU1S / AESV1S-LA (IE1) STANDARD EFFICIENCY

AESV / AESU / AESV-LA Series Squirrel Cage Induction Motor AESV1S / AESU1S / AESV1S-LA (IE1) STANDARD EFFICIENCY AESV / AESU / AESV-LA Series Squirrel Cage Induction Motor AESV1S / AESU1S / AESV1S-LA (IE1) STANDARD EFFICIENCY AESV2S / AESU2S / AESV2S-LA (IE2) HIGH EFFICIENCY AESV3S / AESU3S / AESV3S-LA (IE3) PREMIUM

More information

MJB. Model. Up to kva. Power. Up to V. Voltages. Frame 160 ± 900. Pole 4, 6, 8, 10 and 12. (over contact MM) Cooling IC 01

MJB. Model. Up to kva. Power. Up to V. Voltages. Frame 160 ± 900. Pole 4, 6, 8, 10 and 12. (over contact MM) Cooling IC 01 MJB Model Power Voltages MJB Up to 6.500 kva Up to 1.000 V Frame 160 ± 900 Pole 4, 6, 8, 10 and 12 Cooling IC 01 (over contact MM) IP Enclosure Main Applications Sector IP 23. Available up to IP 44 with

More information

Low Voltage 3-Phase Induction Motors. Range 0.55kW to 500kW TOTALLY ENCLOSED FAN-COOLED CAST IRON FRAME SERIES AUSTRALIA & NEW ZEALAND

Low Voltage 3-Phase Induction Motors. Range 0.55kW to 500kW TOTALLY ENCLOSED FAN-COOLED CAST IRON FRAME SERIES AUSTRALIA & NEW ZEALAND Low Voltage 3-Phase Induction Motors Range 0.55kW to 500kW TOTALLY ENCLOSED FAN-COOLED CAST IRON SERIES General Information MONARCH GX - Three Phase Induction Motors are a range of high quality, Totally

More information

Asynchronous motors. 7/2 Main spindle motors for SIMODRIVE 611 7/2 Introduction

Asynchronous motors. 7/2 Main spindle motors for SIMODRIVE 611 7/2 Introduction / Main spindle motors for SIMODRIVE 611 / Introduction /4 Main spindle motors for SIMODRIVE 611 1PH motors with solid shaft/forced ventilation /18 Main spindle motors for SIMODRIVE 611 1PH4 motors with

More information

Mounting & Maintenance Instructions OMT1 & OMT2 Motors

Mounting & Maintenance Instructions OMT1 & OMT2 Motors Mounting & Maintenance Instructions OMT1 & OMT2 Motors Seite 1 von 10 Inhalt Seite 1 General information 3 2 Delivery 3 3 Mounting 3 4 Coupling 3 4.1 Direct coupling 3 4.2 Indirect coupling 4 4.2.1 Flat

More information

Customised drive solutions

Customised drive solutions Customised drive solutions Electric motors & systems Drive components Services Introduction 03 Halm quality drive technology Over 50 years of experience in developing electric motors with asynchronous

More information

Drive IT Low Voltage General Purpose Motors

Drive IT Low Voltage General Purpose Motors Drive IT Low Voltage General Purpose Motors Making you more competitive ABB s General purpose motors are readily available from central stock locations and distributors throughout the world. While designed

More information

TECHNICAL SPECIFICATION

TECHNICAL SPECIFICATION We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. Copyright 212 ABB TECHNICAL

More information

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalouge

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalouge CENTRIFLOW 3D plug fan WITH AC MOTOR >> Technical catalouge air comfort Centriflow 3D 2 GMEB CentriFlow 3D - Technical Catalouge Contents GENERAL Description and survey chart Application... 3 General Survey

More information

INTER PLANT STANDARD STEEL INDUSTRY

INTER PLANT STANDARD STEEL INDUSTRY INTER PLANT STANDARD STEEL INDUSTRY IPSS SPECIFICATION FOR ac CRANE (Hoist and Winches) DUTY SQUIRREL CAGE INDUCTION MOTORS (Fourth Revision) BASED ON IS 325:1996 Formerly: IPSS:1-03-004-05 0. FOREWORD

More information

TECHNICAL SPECIFICATION

TECHNICAL SPECIFICATION We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. Copyright 212 ABB TECHNICAL

More information

High-voltage motors TOSHIBA MITSUBISHI-ELECTRIC INDUSTRIAL SYSTEMS CORPORATION

High-voltage motors TOSHIBA MITSUBISHI-ELECTRIC INDUSTRIAL SYSTEMS CORPORATION High-voltage motors series TOSHIBA MITSUBISHI-ELECTRIC INDUSTRIAL SYSTEMS CORPORATION series : Combining over 00 years experience with innovative new technology makes the series the right choice for the

More information