1 Ministab e Sterostab 21 lectrodynamic Regulators Guide to selection and technical data M2 M2 AS T3 Y3 Y3 AS s for SINGL-PHAS 230V mains Asyetrical s for SINGL-PHAS 230V mains s for THR-PHAS 400V mains (coon regulation of the three phases) s for THR-PHAS 400V mains (independent regulation of each phase) Asyetrical s for SINGL-PHAS 400V mains (independent regulation of each phase) INPUT STABILIZD OUTPUT The following tables only show models for single-phase 230V and threephase 400V mains. Upon request, stabilizers can be manufactured for 100, 110, 115, 120, 127, 200, 220, 240, 265V single-phase mains, and for 208, 220, 230, 240, 380, 415, 440, 460, 480 and 500V threephase mains. The single-phase models M204, M206, M208 and the threephase models T304, T306 are fitted with a range selector. Therefore, the ratings that each model can deliver are selected by means of the switching device available on the cabinet. For all other models, it is necessary to specify the required. The models listed in the T3 tables perform the voltage regulation on the average of the three phases and are therefore suitable for lines with balanced voltage and for a maximum unbalance between phases up to 50. T3 models, being equipped with just one stabilizing circuit ensuring a coon regulation of the 3 phases, are less expensive. They can be connected to input mains without neutral. The models listed in the Y3 tables are equipped with one stabilizing circuit for each phase, hence they are suitable for unbalanced mains and a maximum unbalance between phases up to 100. For their correct operation, neutral is mandatory. Therefore, the input line must have 4 wires (3 phases + neutral). The voltage regulators do not transform the voltage and deliver in output the input rated value. When input and output voltages are different, an external transformer is required. INPUT SINGL-PHAS M STABILIZRS STABILIZD OUTPUT Ministab and Sterostab correctly operate both at 50 and 60 cycles. Special features on request: output accuracy ±0.5 and optional as per list here below must be previously checked with the factory. All models comply with the requirements of following standards: lectromagnetic Compatibility 89/336/C and following amendments Low lectrical quipment 73/23/C and following amendments. INPUT THR-PHAS T STABILIZRS THR-PHAS Y STABILIZRS T = buck-boost transformer R = variable transformer C = electronic control circuit M = servomotor STABILIZD OUTPUT Optional & special versions: Aeter Frequency meter Digital multer Input or output circuit breaker (with or without earth leakage) Manual or automatic by-pass Isolating transformer Step-up / step-down transformer Surge arrester (lightning protection) Over/under voltage protection Thermal relay Soft start Reversed phase sequence and phase failure protection Tropicalized versions 54 indoor or outdoor versions Customized colour.

2 s for M2SINGL-PHAS 230V 50/60Hz mains figure A figure B ± M ,3 ± M ,3 ±25 14 M ,7 ±20 15 ±1, x385x200 A 20 2,5 11 ±15 18 M ±10 25 M ,7 ±30 20 M ±25 21 M ,4 ±20 23 ±1, x410x A 5 22 ±15 27 M ±10 33 M ±30 24 M ,4 ± M ±20 27 ±1, x425x265 A 7 30 ± M ±10 35 M ±30 24 M ± M ±20 27 ±1, X505X285 A 54 M ±15 30 M ± M ± M ±25 24 M ±20 28 ±1, X396X320 A 80 M ±15 31 M ±10 36 M206L-2 2 8,7 ±30 20 M206L ±25 20 M206L ±20 23 M206L ±15 27 M206L ±10 33 M208L ±30 24 M208L ,4 ±25 25 M208L ±20 27 ±0,5 ±0,5 I, L,V FG,PZ, BT*, BS*, PS* I, L,V FG,PZ, BT*, BS*, PS* x500x B x500x275 M208L ± M208L ± M210L ±30 24 M210L ±25 23 M210L ±20 27 M210L ±15 30 ±0,5 I, L,V FG,PZ, BT*, BS*, PS* x500x275 M210L ± M212AN ±30 20 M212AN ±25 26 M212AN ±20 42 ±1 V, L x650x D M212AN ±15 58 M212AN ± B B

3 s for M2SINGL-PFAS 230V 50/60Hz mains figure D figure M213AN ±30 8 M213AN ±25 9 M213AN ±20 10 M213AN ±15 12 M213AN ±10 18 M214AN ±30 18 M214AN ±25 19 M214AN ±20 21 M214AN ±15 24 M214AN ±10 31 M216AN ±30 18 M216AN ±25 19 M216AN ±20 21 M216AN ±15 24 M216AN ±10 31 M217AN ±30 26 M217AN ±25 28 M217AN ±20 29 M217AN ±15 34 M217AN ±10 45 M218AN ±30 20 M218AN ±25 21 M218AN ±20 23 M218AN ±15 26 M218AN ±10 33 M219AN ±30 27 M219AN ±25 29 M219AN ±20 33 M219AN ±15 38 M219AN ±10 47 ± ±1 V, L x650x D ±1 V, L x650x D ±1 V, L x650x D ±1 V, L x650x D ±1 V, L x650x ±1 V, L x650x V = volmeter PZ = potentiometer L = pilot lamp PS* = surge arresters (optional) FG = out of range indication BT* = electronic voltage relay (optional) = range selector BS* = tripping coil (optional) I = input cicuit breaker

4 s for T3 THR-PHAS 400V 50/60Hz mains with regulation on the average of the three phases figure A figure D T ±30 13 T304-3,5 3,5 5 ±25 15 T ± ±15 21 T ±10 30 T ±30 13 T306-6,5 6,5 9,4 ±25 15 T ± ±15 21 T ±10 30 T308AN ±30 15 T308AN ±25 16 T308AN ±20 18 T308AN ±15 21 T308AN ±10 21 ± ± x300x A ± x445x A ±1 V,L x650x D V = volmeter L = pilot lamp = range selector

5 T3 s for THR-PHAS 400V 50/60Hz mains with regulation on the average of the three phases figure T310AN ±30 10 T310AN ±25 11 T310AN ±20 12 ± ±1 V, L x650x D T310AN ±15 14 T310AN ±10 18 T312AN ±30 10 T312AN ±25 11 T312AN ±20 12 ±1 V, L x650x D T312AN ±15 14 T312AN ±10 18 T314AN ±30 10 T314AN ± T314AN ±20 12 ±1 V, L x650x1300 D T314AN ±15 14 T314AN ± T315AN ±30 14 T315AN ±25 16 T315AN ±20 17 ±1 V, L x650x D T315AN ±15 20 T315AN ±10 26 T316AN ±30 12 T316AN ± T316AN ±20 14 ±1 V, L x650x T316AN ±15 17 T316AN ± T318AN ±30 12 T318AN ± T318AN ±20 16 ±1 V, L x650x1800 T318AN ±15 18 T318AN ± T319AN ±30 21 T319AN ± T319AN ±20 26 ±1 V, L 21 T319AN ± T319AN ±10 46 V = volmeter L = pilot lamp = range selector

6 Y3 s for THR-PHAS 400V 50/60Hz mains with independent regulation on each phase figure D Y304AN3 3 4 ±30 13 Y304AN4.5 4,5 7 ±25 14 Y304AN6 6 9 ±20 16 Y304AN7.5 7,5 11 ±15 18 Y304AN ±10 21 Y306AN6 6 9 ±30 11 Y306AN ±25 12 Y306AN ±20 14 Y306AN ±15 16 Y306AN ±10 19 Y308AN ±30 13 Y308AN ±25 14 Y308AN ±20 16 Y308AN ±15 18 Y308AN ±10 21 Y310AN ±30 13 Y310AN ±25 14 Y310AN ±20 16 Y310AN ±15 18 Y310AN ±10 21 Y311AN ±30 13 Y311AN ±25 14 Y311AN ±20 16 Y311AN ±15 18 Y311AN ±10 21 Y312AN ±30 14 Y312AN ±25 15 Y312AN ±20 24 Y312AN ±15 33 Y312AN ±10 37 ± ±1 V, L x650x D ±1 V, L x650x D ±1 V, L x650x D ±1 V, L x650x D ±1 V, L x650x D ±1 V, L x650x D V = volmeter L = pilot lamp = range selector

7 Y3 s for THR-PHAS 400V 50/60Hz mains with independent regulation on each phase figure ± Y313AN ±30 5 Y313AN ±25 6 Y313AN ±20 6 ±1 V, L x650x Y313AN ±15 7 Y313AN ±10 11 Y314AN ±30 10 Y314AN ±25 11 Y314AN ±20 12 ±1 V, L x650x Y314AN ±15 14 Y314AN ±10 18 Y316AN ±30 10 Y316AN ±25 11 Y316AN ±20 12 ±1 V, L x650x Y316AN ±15 14 Y316AN ±10 18 Y317AN ±30 15 Y317AN ±25 16 Y317AN ±20 17 ±1 V, L x650x Y317AN ±15 20 Y317AN ±10 26 Y318AN ±30 11 Y318AN ± Y318AN ±20 13 ±1 V, L 21 Y318AN ±15 15 Y318AN ± Y319AN ±30 16 Y319AN ± Y319AN ±20 19 ±1 V, L Y319AN ±15 22 Y319AN ± Y320AN ±30 13 Y320AN ± cabinets 2770 Y320AN ±20 16 ±1 V, L 21 3 Y320AN ± cabinets Y320AN ± x650x Y322AN ±30 18 Y322AN ±25 20 Y322AN ±20 23 Y322AN ±15 27 Y322AN ±10 36 Y324AN ±30 18 Y324AN ±25 20 Y324AN ±20 23 Y324AN ±15 27 ±1 V, L 21 ±1 V, L 21 3 cabinets Y324AN ±10 36 T. B. A. V = volmeter L = pilot lamp cabinets

8 MAS Y3AS Asyetrical s for SINGL-PHAS 230V 50/60Hz mains Asyetrical s for THR-PHAS 400V 50/60Hz mains with independent regulation on each phase figure D figure ± M204-1,1AS 1,1 4,8 +15, ± x385x A M206-2,5AS 2, , ± x410x A M208-3,5AS 3, , ± x425x A M210-7AS , ± x685x A M211AN10AS , ±1 V, L x650x D M212AN14AS , ±1 V, L x650x D M213AN18AS , ±1 V, L x650x D M214AN29AS , ±1 V, L x650x D M216AN40AS , ±1 V, L x650x D M217AN59AS , ±1 V, L x650x M218AN80AS , ±1 V, L x650x M219AN115AS , ±1 V, L The products described herein, including without limitation, product features, specifications, designs, availability are subject to change by IRM at any without notice. ± Y304AN3,3AS 3, , ±1 V, L x650x D Y306AN7,5AS 7, , ±1 V, L x650x D Y308AN10,5AS 10, , ±1 V, L x650x D Y310AN21AS , ±1 V, L x650x D Y311AN30AS , ±1 V, L x650x D Y312AN40AS , ±1 V, L x650x Y313AN55AS , ±1 V, L x650x Y314AN85AS , ±1 V, L x650x Y316AN120AS , ±1 V, L x650x Y317AN175AS , ±1 V, L x650x Y318AN240AS , ±1 V, L 21 Y319AN345AS , ±1 V, L 21 Y320AN440AS , ±1 V, L 21 Y322AN550AS , ±1 V, L 21 Y324AN800AS , ±1 V, L 21 V = volmeter L = pilot lamp 2 cabinets 2 cabinets 4 cabinets 4 cabinets 4 cabinets IRM SpA a socio unico - Via Abegg Borgone - Torino - ITALY Tel Fax

Ministab and Sterostab IP54 indoor

Ministab and Sterostab IP54 indoor Minist nd Sterost IP54 indoor Electrodynmic Voltge Regultors wit IP54 protection degree for indoor instlltion. INPUT INPUT Guide to selection nd tecnicl dt. M2 M2 AS T3 Syetricl s for SINGLE-PHASE 230V

More information

Micro-Hydroelectric Power Plants ENERGY AND SAVING FROM WATER

Micro-Hydroelectric Power Plants ENERGY AND SAVING FROM WATER Micro-Hydroelectric Power Plants ENERGY AND SAVING FROM WAER Ecowatt Hydro micro-hydroelectric power plants Uses Water is the ideal renewable power source, used by man since the beginning of time. Ecowatt

More information

EBARA. System PUMP W. Uniquely EBARA Variable Speed (VFD) System. Custom built for ideal water supply system... EBARA. System DIMENSION APPLICATIONS

EBARA. System PUMP W. Uniquely EBARA Variable Speed (VFD) System. Custom built for ideal water supply system... EBARA. System DIMENSION APPLICATIONS BARA IMNSION PUMP PHAS INICATING LIGHT Power 4 1 Pump ater Function FCR-01 FILTR BARA ISCHARG Uniquely BARA Variable Speed (VF) Type VI '' SI VI MOL 1 LITR 4-VM 3 1730 7 1 18 MANIFOL 4-VM 5 1730 7 1 18

More information

KD LV Motor Protection Relay

KD LV Motor Protection Relay 1. Protection Features KD LV Motor Protection Relay Overload (for both cyclic and sustained overload conditions) Locked rotor by vectorial stall Running stall / jam Single phasing / Unbalance Earth leakage

More information

ORION PLUS three-phase kVA

ORION PLUS three-phase kVA ORION PLUS three-phase 30-1250kVA Orion Plus stabilizers are available for different ranges of input voltage fluctuation. In the ±15%/ ±20% and ±25%/ ±30% types, the change of input range is obtained through

More information

Type SOQ Negative Sequence Time Overcurrent Relay

Type SOQ Negative Sequence Time Overcurrent Relay ABB Power T&D Company Inc. Power Automation & Protection Division Coral Springs, FL Allentown, PA April 1998 Supersedes DB dated August 1991 Mailed to: E,D, C/41-100B For Protection of Rotating Machinery

More information

EPS-ECONOMY PUMP STARTER

EPS-ECONOMY PUMP STARTER EPS-ECONOMY PUMP STARTER NEMA 1 & 3R ENCLOSURES franklinwater.com EPS-ECONOMY PUMP STARTER - 1 & 3 PHASE, 50/60HZ, 200-600 VAC, 1-80A The enhanced Franklin Electric Economy Pump Starter (EPS) provides

More information

NATIONAL CERTIFICATE (VOCATIONAL) ELECTRICAL SYSTEMS AND CONSTRUCTION NQF LEVEL 3 NOVEMBER 2009

NATIONAL CERTIFICATE (VOCATIONAL) ELECTRICAL SYSTEMS AND CONSTRUCTION NQF LEVEL 3 NOVEMBER 2009 NATIONAL CERTIFICATE (VOCATIONAL) ELECTRICAL SYSTEMS AND CONSTRUCTION NQF LEVEL 3 NOVEMBER 2009 (12041033) 24 November (X-Paper) 09:00 12:00 This question paper consists of 6 pages. (12041033) -2- NC720(E)(N24)V

More information

LA Motor Protection. A South African Company to be Proud of

LA Motor Protection. A South African Company to be Proud of LA Motor Protection Relay Physical Address: 298 Soutter Street, Pretoria West Tel: 083 454 6949, +27 12 327 1729 Fax: +27 (0)12 327 1733 Toll Assist: 0860 10 30 41 www.newelec.co.za sales@newelec.co.za

More information

THP145 HYBRID GAS INSULATED SWITCHGEAR (HGIS) Energy, Fast! tgood.com

THP145 HYBRID GAS INSULATED SWITCHGEAR (HGIS) Energy, Fast! tgood.com THP145 HYBRID GAS INSULATED SWITCHGEAR (HGIS) Energy, Fast! tgood.com TGOOD produces over 5000 switchgear units annually for projects around the globe SOLUTION OVERVIEW For use in affordable air insulated

More information

7.0 Technical Guarantee Specification of 60MVA, 132/33kV Mobile Substation. TECHNICAL DATA SCHEDULE 60MVA, 132/33 kv MOBILE SUBSTATION

7.0 Technical Guarantee Specification of 60MVA, 132/33kV Mobile Substation. TECHNICAL DATA SCHEDULE 60MVA, 132/33 kv MOBILE SUBSTATION 92 Section VI. Schedule of Requirements 7.0 Technical Guarantee Specification of 60MV, 132/33 Mobile Substation TECHNICL DT SCHEDULE 60MV, 132/33 MOBILE SUBSTTION ITEM DESCRIPTION UNITS REQUIRED GURNTEED

More information

General Purpose Buck - Boost Wiring Diagrams... 86

General Purpose Buck - Boost Wiring Diagrams... 86 SECTION LOW VOLTAGE/ LIGHTING TRANSFORMERS General Purpose... 84 Buck - Boost... 85 Wiring Diagrams... 8 LOW VOLTAGE LIGHTING TRANSFORMERS & POWER SUPPLIES Low Voltage Lighting A greater selection for

More information

Install a module ME or MT

Install a module ME or MT Install a module ME or MT.5.202 Build a converter with a Booster module. ME modules deliver unbalanced three-phase voltages, sufficient for machines with threephase motors. MT produces balanced three-phase

More information

Domae. The right solution for distribution boards

Domae. The right solution for distribution boards Domae The right solution for distribution boards Guaranteed quality and adapted solutions Domae : SIRIM approved The quality marks prove product conformity to their reference standard. They guarantee:

More information

Switchgear and Distribution Systems for Engineers and Technicians

Switchgear and Distribution Systems for Engineers and Technicians Switchgear and Distribution Systems for Engineers and Technicians WHAT YOU WILL LEARN: How to identify typical characteristics of an industrial distribution system Become familiar with the main components

More information

Film-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment.

Film-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment. Film-Tech The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment. These manuals are designed to facilitate the exchange of information related to cinema

More information

MEDIUM VOLTAGE PRODUCT. TJC 4 Indoor voltage transformers

MEDIUM VOLTAGE PRODUCT. TJC 4 Indoor voltage transformers MEDIUM VOLTAGE PRODUCT TJC 4 Indoor voltage transformers 2 TJC 4 INDOOR VOLTAGE TRANSFORMERS Parameters Highest voltage for equipment Power frequency test voltage, 1 min. Lightning impulse test voltage

More information

ELECTRICAL PANELS. Chap.

ELECTRICAL PANELS. Chap. ELECTRICAL PANELS 360 Panel System Electrical Panels 360 Panel System Modular Panels DC Electric Panels AC Electric Panels AC/DC Electric Panels Aber Marine Panels IP 67 Watertight Panels Rotary Switch

More information

SUBMERSIBLE PUMP HSE RANGE

SUBMERSIBLE PUMP HSE RANGE SUBMERSIBLE PUMP HSE RANGE OPERATION & MAINTENANCE INSTRUCTIONS 0806 SPECIFICATIONS Model No. HSE120* HSE200 HSE300*/ HSE360*/ HSEC400* HSE301 HSE361 Outlet Dia. (mm/inches) 32/1-1/4 38/1-1/2 50/2 50/2

More information

Control and protection of the electrical energy

Control and protection of the electrical energy Specialists in CONTROL & EFFICIENCY of electrical motors Automation and Industrial Control Control and protection of the electrical energy Efficiency in the most ambitious projects thanks to the confidence

More information

ASYN205B Central Synchronizing Controller

ASYN205B Central Synchronizing Controller ASYN205B Central Synchronizing Controller Function 3 phase active power transducer, one auxiliary analog Genset power control Genset voltage frequency control Multi-gensets power balance control Selectional

More information

Key features. DESIGNS: - Conservator type - Hermetically sealed

Key features. DESIGNS: - Conservator type - Hermetically sealed Package Substations OTDS manufactures a large range of oil filled hermitically sealed and conservator type transformers to be used in conjunction with our package substations. We are able to utalise the

More information

1 Phase electronic contactor (SC 1)

1 Phase electronic contactor (SC 1) 1 Phase electronic contactor (SC 1) - Rated operational voltage up to 600VAC 50/60 Hz - Rated operational current up to 15/30A/50/63A AC-1 - Control voltage from or - Compact modular design 22.5, 45, or

More information

SUBMERSIBLE PUMP HSE RANGE

SUBMERSIBLE PUMP HSE RANGE SUBMERSIBLE PUMP HSE RANGE OPERATION & MAINTENANCE INSTRUCTIONS 0707 SPECIFICATIONS HSE300* HSE360* Model No. HSE130* HSE200A HSE300A HSE360A HSEC400* HSE301A HSE361A Outlet Dia. (mm/inches) 32/1-1/4 38/1-1/2

More information

Components for EEx e Panels

Components for EEx e Panels Circuit Interrupters / Motor Switches 8006/3 8543/1 8543/2 8548/2 40 A 63 A 80 A 1 160 A 500 V 660 V 500 V 01766E00 No. of poles 12 poles Isolator features Switching capacity 400 V, AC3 11 kw 22 kw 37

More information

Film-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment.

Film-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment. Film-Tech The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment. These manuals are designed to facilitate the exchange of information related to cinema

More information

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor World Leader in Modular Torque Limiters Installation and Maintenance Instructions PTM-4 Load Monitor 1304 Twin Oaks Street Wichita Falls, Texas 76302 (940) 723-7800 Fax: (940) 723-7888 E-mail: sales@brunelcorp.com

More information

TECHNICAL DESCRIPTION

TECHNICAL DESCRIPTION DC Circuit Breaker TECHNICAL DESCRIPTION TRK5650515200 Ed.1 of 21/02/13 CONTENTS 1. INTRODUCTION... 2 2. DESCRIPTION... 2 2.1 Description of circuit breaker... 2 2.2 Operating mode... 2 2.3 Variants and

More information

PHASE CONVERTERS OPERATING & MAINTENANCE INSTRUCTIONS. MODEL NO: PC40 and PC60. PART Nos:

PHASE CONVERTERS OPERATING & MAINTENANCE INSTRUCTIONS. MODEL NO: PC40 and PC60. PART Nos: PHASE CONVERTERS MODEL NO: PC40 and PC60 MODEL PART No: NO: 6012805 PC20 and PC40 6012810 PC60 PART Nos: 6012800 6012805 6012810 OPERATING & MAINTENANCE INSTRUCTIONS 0107 Specifications PC20 PC40 PC60

More information

8036-A0 Motor Drives Training System (Stand-Alone)

8036-A0 Motor Drives Training System (Stand-Alone) 8036-A0 Motor Drives Training System (Stand-Alone) LabVolt Series Datasheet Festo Didactic en 120 V - 60 Hz 04/2018 Table of Contents General Description 2 List of Equipment 2 List of Manuals 2 Table of

More information

Motor Drives Training System (Stand-Alone, 120 V Version) (8036-C0)

Motor Drives Training System (Stand-Alone, 120 V Version) (8036-C0) Motor Drives Training System (Stand-Alone, 120 V Version) 581526 (8036-C0) LabVolt Series Datasheet Festo Didactic en 120 V - 60 Hz 11/2018 Table of Contents General Description 2 List of Equipment 2 List

More information

Training & Didactic Systems. Fundamentals of Electrical Engineering

Training & Didactic Systems. Fundamentals of Electrical Engineering Training & Didactic Systems Fundamentals of Electrical Engineering Catalog WA1E/01 Table of Contents Page Our Service, Our Customers and fields of technology 2 Introduction 4 Instruction modules measuring

More information

KYN28A-12 (GZS1) A.C METALCLAD REMOVABLE SWITCHGEAR FOR INDOOR USE CHINATCS

KYN28A-12 (GZS1) A.C METALCLAD REMOVABLE SWITCHGEAR FOR INDOOR USE CHINATCS KYN28A-12 (GZS1) A.C METALCLAD REMOVABLE SWITCHGEAR FOR INDOOR USE CHINATCS 2001.09 KYN28A-12 (GZS1) A.C Metalclad Removable Switchgear for Indoor Use --------The Leader in Switchgear Up to 12kV 1. The

More information

DESIGN CONSIDERATIONS FOR APPLICATION OF SHUNT CAPACITORS IN HEAVY HATER PLANT (TUTICORIN)

DESIGN CONSIDERATIONS FOR APPLICATION OF SHUNT CAPACITORS IN HEAVY HATER PLANT (TUTICORIN) DESIGN CONSIDERATIONS FOR APPLICATION OF SHUNT CAPACITORS IN HEAVY HATER PLANT (TUTICORIN) -A.R. Subraaanian -R.A.A. Palani -J. Thomson A new 3.3 K.V. 4200 KVAR auto switching capacitor bank has been installed

More information

DRY TYPE TRANSFORMERS

DRY TYPE TRANSFORMERS DRY TYPE Trafotek transformers are made to meet customer requirements in demanding applications. We are specially focused on manufacturing transformers for different types of frequency converters and special

More information

ahead of time Voltage Stabilisers

ahead of time Voltage Stabilisers ahead of time Voltage Stabilisers Founded in 1969, ORTEA SpA is a leading company in manufacturing and engineering stabilisers and magnetic components. Over forty years in the business and ongoing technical

More information

New dimming drivers are compatible with most wall dimmers for % light control. For non-dimming

New dimming drivers are compatible with most wall dimmers for % light control. For non-dimming CONSTANT VOLTAGE POWER SUPPLIES CONSTANT VOLTAGE New dimming drivers are compatible with most wall dimmers for 10-100% light control. For non-dimming applications or for use with AL-PWM-6A, use LED-DR

More information

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW Page 1 of 6 3-Phase Panel Mount 86 and 105kW Features: Benefits: 0-10Vdc, 0-5Vdc, 4-20mA or manual via potentiometer control input Over temperature protection with auto reset Enclosed panel mounting Efficient

More information

EM/EMS Electronic Servo AC Stabilisers and Power Conditioners. EM/EMS Range Brochure

EM/EMS Electronic Servo AC Stabilisers and Power Conditioners. EM/EMS Range Brochure EM/ Electronic Servo AC Stabilisers and Power Conditioners EM/ Range Brochure Introduction True World Leadership World status is all too easy to claim, but Watford Control can offer the solid proof. Established

More information

GP Dimming Panels 230 Volt (CE)

GP Dimming Panels 230 Volt (CE) GAFIK Systems 30 Volt (CE) gp- 03.0.04 GP3/4 Mini Panels GP8-4 Standard-Size Panels provide power and dimming for up to 4 load circuits and control any light source, including full-conduction non-dim.

More information

Gas-Insulated Switchgear. Type 8VN1 blue GIS up to 145 kv, 40 ka, 3150 A

Gas-Insulated Switchgear. Type 8VN1 blue GIS up to 145 kv, 40 ka, 3150 A Gas-Insulated Switchgear Type 8VN1 blue GIS up to 145 kv, 40 ka, 3150 A siemens.com/energy-management Table of content Gas-insulated switchgear Product portfolio 72.5 550 kv Vacuum interrupters for switching

More information

Modular medium-voltage switchgear. NorMax

Modular medium-voltage switchgear. NorMax Modular medium-voltage switchgear NorMax NorMax MODULAR MEDIUM-VOLTAGE SWITCHGEAR 2 NorMax Modular medium-voltage switchgear Contents Subject Page Table of contents 2 Introduction and main features 2 Technical

More information

Series Motor Protection

Series Motor Protection 320-327 Series Motor Protection Relay Physical Address: 298 Soutter Street, Pretoria West Tel: 083 454 6949, +27 12 327 1729 Fax: +27 (0)12 327 1733 Toll Assist: 0860 10 30 41 www.newelec.co.za sales@newelec.co.za

More information

MODEL 540 USER MANUAL INCORPORATING MODEL 530 TEMPERATURE CONTROLLER

MODEL 540 USER MANUAL INCORPORATING MODEL 530 TEMPERATURE CONTROLLER MODEL 540 USER MANUAL INCORPORATING MODEL 530 TEMPERATURE CONTROLLER Signal Group Limited 12 Doman Road, Camberley Surrey, GU15 3DF England Tel: +44 (0) 1276 682841 Fax: +44 (0) 1276 691302 e-mail: instruments@signal-group.com

More information

Liquid filled Thermometers

Liquid filled Thermometers Liquid filled Thermometers Description and general specifications Liquid filled contact thermometers Operating instructions and maintenance Finished product quality control tests 02 02 05 06 1 Description

More information

Motor-drive mechanism, type BUL. Technical guide

Motor-drive mechanism, type BUL. Technical guide Motor-drive mechanism, type BUL Technical guide This Technical Guide has been produced to allow transformer manufacturers, and their designers and engineers, access to all the technical information required

More information

Pumped Storage Power Plants Solution

Pumped Storage Power Plants Solution GE Grid Solutions Pumped Storage Power Plants Solution Flexibility for Grid Operators Pumped storage power plants are the largest and most cost-effective means of storing energy for electricity grids.

More information

CT-GB-39/05 VOLTAGE STABILISERS 1

CT-GB-39/05 VOLTAGE STABILISERS 1 CT-GB-39/05 Since 1969, ORTEA SpA is a leading manufacturer of voltage stabilisers, magnetic components and electrical equipment. Such position has been reached thanks to the sound professional skills

More information

NEW The new PROmax power supplies offer a wide range of robust solutions for demanding application requirements.

NEW The new PROmax power supplies offer a wide range of robust solutions for demanding application requirements. Datasheet Single- and three-phase switched-mode power supply units NEW The new power supplies offer a wide range of robust solutions for demanding application requirements. C SEMI F47 US Designed for high

More information

White Paper. Ground Fault Application Guide. WL Low Voltage Power Circuit Breakers

White Paper. Ground Fault Application Guide. WL Low Voltage Power Circuit Breakers White Paper Ground Fault Application Guide WL Low Voltage Power Circuit Breakers Table of Contents Introduction 3 Need for ground fault tripping 3 Requirements from industry standards 3 National Electrical

More information

GP Dimming Panels. GRAFIK Systems SPECIFICATION SUBMITTAL

GP Dimming Panels. GRAFIK Systems SPECIFICATION SUBMITTAL rev gp-a 7.0.00 GP3/4 Mini Panels GP8-4 Standard-Size Panels DESCRIPTION Provide power and dimming for up to 44 load circuits. Control any light source, including full-conduction non-dim. Models available

More information

The following lighting types are NOT compatible with the TT- 402Wireless Inline Dimmers:

The following lighting types are NOT compatible with the TT- 402Wireless Inline Dimmers: TT402 (300W) Incandescent Wireless receiver Inline Dimmer Product Description The TT- 402is a 40-300W dimmable wireless receiver. It can be paired with only circuits 1 and 2 (keys 4 or 5) on the Taptile

More information

TRAVEL CORDSET AND WALL STATION TEST REPORT

TRAVEL CORDSET AND WALL STATION TEST REPORT GENERAL MOTORS TRAVEL CORDSET AND WALL STATION TEST REPORT REVISION 4 EVSE Model: Click here to enter text. Serial Number: Click here to enter text. Test Engineer: Click here to enter text. Date: Click

More information

Auxiliary Relay (7PJ11) and Trip Relay (7PJ12)

Auxiliary Relay (7PJ11) and Trip Relay (7PJ12) s www.siemens.com/energy Auxiliary Relay (7PJ) and Trip Relay (7PJ2) Better protection and more efficiency for your power system Answers for infrastructure and cities. Auxiliary Relay and Trip Relay Catalogue

More information

Solar Power Switchgear & Energy Storage Renewable Energy Systems

Solar Power Switchgear & Energy Storage Renewable Energy Systems 7 Solar Power Switchgear & Energy Storage Renewable Energy Systems - Solution Brochure www.apt-power.com 433 N. 36 th Street PROVIDING A COMPREHENSIVE Lafayette, IN 47905 www.apt-power.com 433 APPROACH

More information

DEEP SEA ELECTRONICS PLC

DEEP SEA ELECTRONICS PLC COMPLEX SOLUTIONS MADE SIMPLE DEEP SEA ELECTRONICS PLC DSE720 AUTOSTART CONTROL MODULE OPERATING MANUAL http://bestgenerator.spb.ru/?page_id=6765 Deep Sea Electronics Plc Highfield House Hunmanby North

More information

EST Electrical Service Technician Answer Schedule

EST Electrical Service Technician Answer Schedule EST 2075 - Electrical Service Technician Answer Schedule Notes:1. means that the preceding statement/answer earns 1 mark. 2. This schedule sets out the accepted answers to the examination questions. A

More information

LP Dimming Panels. GRAFIK Systems

LP Dimming Panels. GRAFIK Systems GAFIK Systems lp-1 12.8.03 are ideal for projects with many small loads. Each panel provides power and dimming for up to 32 dimming legs. Features Work directly with incandescent, magnetic low voltage,

More information

Power Systems Trainer

Power Systems Trainer Electrical Power Systems PSS A self-contained unit that simulates all parts of electrical power systems and their protection, from generation to utilisation Key Features Simulates generation, transmission,

More information

Planning Low Voltage Layouts

Planning Low Voltage Layouts Outdoor_ransformers_Outdoor_ransformers.qxd 11-11-10 3:40 PM Page 1 1850 Wilson Avenue, oronto, Ontario, anada, M9M 1A1 Ph: 416-741-7336 Fax: 416-741-9104 SEION H OUDOOR H1 OUDOOR Low Voltage ransformers

More information

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2 OPERATING AND MAINTENANCE MANUAL Product: Type: Primary Current Injection Test Set 750ADM mk2 750ADM-H mk2 DESIGNED AND MANUFACTURED BY: T & R Test Equipment Limited 15-16 Woodbridge Meadows, Guildford,

More information

UBC Technical Guidelines Section Edition Commissioning of Electrical Systems Page 1 of 5

UBC Technical Guidelines Section Edition Commissioning of Electrical Systems Page 1 of 5 Page 1 of 5 1.0 GENERAL 1.1 Coordination Requirements.1 UBC Building Operations Electrical Technical Support.2 UBC Energy & Water Services 2.0 REQUIREMENTS FOR COMMISSIONING AND TESTING 2.1 Testing.1 Unit

More information

SITE PLANNING DATA LIEBERT EXM 3-PHASE UPS: KVA/KW, 60HZ, VAC, SINGLE INPUT

SITE PLANNING DATA LIEBERT EXM 3-PHASE UPS: KVA/KW, 60HZ, VAC, SINGLE INPUT SITE PLANNING DATA LIEBERT EXM 3-PHASE : 10-100KVA/K, 60HZ, 208-480VAC, SINGLE INPUT MAINTENANCE BYPASS CABINET Busbar * System 3 ire + GND BIB MBB MIB Note 6 AC 208V 4 ire + GND Static Bypass Local Grounding

More information

EPS-ECONOMY PUMP STARTER

EPS-ECONOMY PUMP STARTER EPS-ECONOMY PUMP STARTER 1 & 3 Phase, 50/60Z, 200-600 VAC, 1-80A The enhanced Franklin Electric Economy Pump Starter (EPS) provides a simple and dependable starting option with a wide electronic overload

More information

331-SV. User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER. Ashland, OH

331-SV. User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER. Ashland, OH 331-SV User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER Ashland, OH 800-363-5842 WWW.PRIMEXCONTROLS.COM Warranty void if panel is modified. Call factory with servicing

More information

M-RING 24. SF6 Insulated Ring Main Unit Metal-Enclosed (LSC2A)

M-RING 24. SF6 Insulated Ring Main Unit Metal-Enclosed (LSC2A) M-RING 24 SF6 Insulated Ring Main Unit Metal-Enclosed (LSC2A) Contents General Description Advanced facilities and process Advanced design philosophy Definition of M-RING 24 Standards Service conditions

More information

High Voltage Products. COMPASS Compact Prefabricated Air Insulated Substation

High Voltage Products. COMPASS Compact Prefabricated Air Insulated Substation High Voltage Products COMPASS Compact Prefabricated Air Insulated Substation Focus factory The ABB Focus Factory based in Lodi, Italy is one of the facilities belonging to the ABB Group, it deals with

More information

SECTION MOTOR CONTROL

SECTION MOTOR CONTROL SECTION 26 24 19 MOTOR CONTROL PART 1 - GENERAL 1.1 SECTION INCLUDES A. Manual motor starters B. Magnetic motor starters C. Combination magnetic motor starters D. Solid-state reduced voltage motor starters

More information

ic60h (6kA) single module combined RCD/MCB units ic60h (10kA) single module combined RCD/MCB units ild residual current circuit breakers idpn N Vigi

ic60h (6kA) single module combined RCD/MCB units ic60h (10kA) single module combined RCD/MCB units ild residual current circuit breakers idpn N Vigi Contents Miniature circuit breakers ic60n miniature circuit breakers 6kA, C curve, 6-63A ic60h miniature circuit breakers 10kA, C curve, 6-63A ic60n miniature circuit breakers 6kA, B curve, 6-63A ic60h

More information

Offers. QOvs RCBO residual current devices. Protection Earth leakage protection. Variants

Offers. QOvs RCBO residual current devices. Protection Earth leakage protection. Variants devices Offers This page must be removed before publishing The Schneider Electric residual current devices range comprises various offers (A, B, C, D) so as to be as competitive as possible in each country,

More information

Basic function. Rated current. Appropriate for three-phase motors of output 2) [kw] I n. = 400 V a.c. 2) Appropriate for three-phase motors

Basic function. Rated current. Appropriate for three-phase motors of output 2) [kw] I n. = 400 V a.c. 2) Appropriate for three-phase motors MOTOR STARTERS SM Basic function Switching and protection of motors up to A Protection against short-circuit and protection against overload The device responds to phase failure The device is provided

More information

This tender addendum and clarification forms part of the Request for Proposal and Contract documents, and modifies them as follows:

This tender addendum and clarification forms part of the Request for Proposal and Contract documents, and modifies them as follows: This tender addendum and clarification forms part of the Request for Proposal and Contract documents, and modifies them as follows: I. ADDENDUM Isinya Mandatory Spares list Description Quantity A AIS 400kV

More information

Contact Details: Mail Id:

Contact Details: Mail Id: Product Brochure Contact Details: +91 8308839755 Mail Id: savikenterprises@yahoo.co.in Contents Solid State Relay... - 3 - Thyristor Heater/Power Controllers... - 6 - Emergency Alarm System... - 9 - Thyristor

More information

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications ABB a global leader ABB is a global leader in power and automation technologies that enable utility and industry customers

More information

OpenEVSE - 40A Charging Station

OpenEVSE - 40A Charging Station OpenEVSE - 40A Charging Station P50 Advanced P50 Standard http://www.openevse.com Read and save these instructions prior to installing and operating your Charging Station. Retain this installation guide

More information

INSTALLATION & MAINTENANCE MANUAL HBL

INSTALLATION & MAINTENANCE MANUAL HBL INSTALLATI & MAINTENANCE MANUAL HBL series 230V 50Hz IP 65 122 1 GENERAL INSTRUCTIS These instructions should be read carefully and retained after installation by the end user for future reference and

More information

ISO-TECH IPS1810H and IPS1603D DC power supply ISO-TECH IPS 1810H et IPS 1603D Alimentation électrique c.c.

ISO-TECH IPS1810H and IPS1603D DC power supply ISO-TECH IPS 1810H et IPS 1603D Alimentation électrique c.c. ISO-TECH IPS1810H and IPS1603D DC power supply ISO-TECH IPS 1810H et IPS 1603D Alimentation électrique c.c. ISO-TECH IPS 1810H 204-713 ISO-TECH IPS 1603D 204-729 82IP-1810HME Ei Statement of Compliance

More information

Relcotech Transformer Manufacturer Sdn. Bhd. Flood Light. Description. Model: S MH70W S MH150W. Specification: Ingress Protection: IP65

Relcotech Transformer Manufacturer Sdn. Bhd. Flood Light. Description. Model: S MH70W S MH150W. Specification: Ingress Protection: IP65 tech Transformer Manufacturer Sdn. Bhd. Flood Light Model: S70150 - MH70W S70150 - MH150W Specification: Ingress Protection: IP65 Voltage: 220V ~ 240VAC 50Hz Lamp Wattage: 70W ~ 150W Holder Type: RX7s

More information

ZF SERIES HV GAS INSULATED SWITCHGEAR (GIS) tgood.com. Energy. Fast.

ZF SERIES HV GAS INSULATED SWITCHGEAR (GIS) tgood.com. Energy. Fast. ZF SERIES HV GAS INSULATED SWITCHGEAR (GIS) tgood.com Energy. Fast. TGOOD produces over 5000 switchgear units annually for projects around the globe PRODUCT OVERVIEW High performance alternative to air

More information

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR ANGLER SWITCHING DEVICES CONTENTS 1. General 2. Switchgear Types - Switch Disconnector - Disconnector 3. Cubicle Types - Cubicle with Switch Disconnector

More information

NEPAL ELECTRICITY AUTHORITY (A Government of Nepal Undertaking)

NEPAL ELECTRICITY AUTHORITY (A Government of Nepal Undertaking) NEPAL ELECTRICITY AUTHORITY (A Government of Nepal Undertaking) Generation Directorate Medium Generation Operation and Maintenance Department SUNDARIJAL HYDROPOWER PLANT REHABILITATION PROJECT Electricity

More information

SafeGear TM Motor Control Center Arc resistant metal-clad construction Motor Control Center Descriptive bulletin

SafeGear TM Motor Control Center Arc resistant metal-clad construction Motor Control Center Descriptive bulletin SafeGear TM Motor Control Center Arc resistant metal-clad construction Motor Control Center Descriptive bulletin Contents 1. Introduction 2 2. Product highlights 2 3. Available configuration/competitive

More information

schneider-electric.com/sg K60 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads schneider-electric.

schneider-electric.com/sg K60 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads schneider-electric. K0 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads Overview K0 Circuit Breaker Technical Specification MCB RCCB K0 Circuit Breaker K0N K0H ID K Number of poles

More information

XCITE Owner s Manual. Reso-not TM Damping System XCITE 1502C HYDRAULIC POWER SUPPLY

XCITE Owner s Manual. Reso-not TM Damping System XCITE 1502C HYDRAULIC POWER SUPPLY Reso-not TM Damping System XCITE Owner s Manual 1502C HYDRAULIC POWER SUPPLY Xcite Systems Corporation 675 Cincinnati RDS Batavia - 1 Pike Cincinnati, Ohio 45245 Tel: (239) 980-9093 Fax: (239) 985-0074

More information

SF 6 Gas Insulated Switchgear Type SDH714 for 72.5 to 145 kv

SF 6 Gas Insulated Switchgear Type SDH714 for 72.5 to 145 kv Three-phase Encapsulated Type SF 6 Gas Insulated Switchgear Type SDH714 for 72.5 to 145 kv 06B1-E-0020 Small Space Requirement, High Reliability and Safety ー 72.5 to 145kV GIS, SDH714 The number of application

More information

Compresseur scroll. Refrigerant R410A SYSAQUAC. Air Cooled Condensing Units Models 25 to to 136.0kW

Compresseur scroll. Refrigerant R410A SYSAQUAC. Air Cooled Condensing Units Models 25 to to 136.0kW Compresseur scroll Refrigerant R410A SYSAQUAC Air Cooled Condensing Units Models 25 to 125 32.0 to 136.0kW SYSAQUA Condensation 1 Key Points R410A refrigerant, Units are optimized for partial load operation,

More information

Sharda Electronics & Co. An ISO 9001:2015 Certified Company

Sharda Electronics & Co. An ISO 9001:2015 Certified Company Sharda Electronics & Co. An ISO 9001:2015 Certified Company Business Profile We have been witnessing to change all our life and change continues to happen all around us every moment. Change is happening

More information

PRODUCTS: POWER SUPPLY

PRODUCTS: POWER SUPPLY PRODUCTS: POWER SUPPLY Impact Lighting Inc. All rights reserved. Impact Lighting Inc. Reserves the right to change specifications without notice. 138 POWER SUPPLY 15W AC-DC [12V/1.25A] UNIVERSAL POWER

More information

Ingersoll Rand PowerSource Specification. Engine data. Alternator data. Fuel consumption. Ingersoll Rand

Ingersoll Rand PowerSource Specification. Engine data. Alternator data. Fuel consumption. Ingersoll Rand Ingersoll Rand PowerSource Specification Model Prime power Standby power G160 158 kva 174 kva Engine data Make Ingersoll Rand Model 6IRF8AE Rated speed 1500 rpm Prime output @ rated speed 139 kw Standby

More information

Temperature controller. Side. Vac 3. Typically. Temperature controller. Side. Vac Driving SSR. Temperature controller. Resistor. Vac.

Temperature controller. Side. Vac 3. Typically. Temperature controller. Side. Vac Driving SSR. Temperature controller. Resistor. Vac. Solid State Relays Vdc Input/ Output, Input/ Output High Reliability Shown smaller than actual size ac Controlled used with Controller with dc Voltage Driver Output L Typically ac Controlled used with

More information

DEEP SEA ELECTRONICS PLC

DEEP SEA ELECTRONICS PLC COMPLEX SOLUTIONS MADE SIMPLE. DEEP SEA ELECTRONICS PLC DSE710 AUTOSTART CONTROL MODULE OPERATING MANUAL Deep Sea Electronics Plc Highfield House Hunmanby North Yorkshire YO14 0PH ENGLAND Sales Tel: +44

More information

PRODUCT CATALOGUE 2016

PRODUCT CATALOGUE 2016 PRODUCT CATALOGUE 2016 Static digital voltage stabilisers The static stabiliser is used when the correction speed represents the critical issue (for example, computers, laboratory equipment, measuring

More information

DEEP SEA ELECTRONICS PLC

DEEP SEA ELECTRONICS PLC COMPLEX SOLUTIONS MADE SIMPLE DEEP SEA ELECTRONICS PLC DSE704 AUTOSTART CONTROL MODULE OPERATING MANUAL 057-042 704 Operating Instructions Issue 2.1 18/06/2007 11:27:00 JR - 1 - Deep Sea Electronics Plc

More information

Installation Manual. RW240/400/600 Motor Gearbox

Installation Manual. RW240/400/600 Motor Gearbox Installation Manual RW240/400/600 Motor Gearbox Ridder Drive Systems Lorentzstraat 36-38 C 3846 AX Harderwijk P.O. Box 360 C 3840 AJ Harderwijk The Netherlands T +31 (0)341 416 854 C F +31 (0)341 416 611

More information

AA4006 Speed Sensitive Trip Unit. User Manual

AA4006 Speed Sensitive Trip Unit. User Manual AA4006 Speed Sensitive Trip Unit User Manual Software Version 2.00 Issued 01/2005 Don Controls Limited Westfield Industrial Estate Kirk Lane, Yeadon Leeds, LS19 7LX Telephone: +44 (0)845 1304946 Fax: +44

More information

INSTALLATION MANUAL. Instructions, precautions, suggestions for installing and servicing resin transformers in full compliance with safety rules

INSTALLATION MANUAL. Instructions, precautions, suggestions for installing and servicing resin transformers in full compliance with safety rules INSTALLATION MANUAL Instructions, precautions, suggestions for installing and servicing resin transformers in full compliance with safety rules ING TABLE OF CONTENTS 1. General information 2 1.1 Standards

More information

technical data Systems RSX(Y)P-K7W1 Inverter cooling only / heat pump series

technical data Systems RSX(Y)P-K7W1 Inverter cooling only / heat pump series technical data Systems RSX(Y)P-K7W1 Inverter cooling only / heat pump series Inverter cooling only / heat pump series RSX(Y)P5,8,10K7W1 RSX(Y)P-K7W1 1 Inverter cooling only / heat pump series 1 1 Specifications

More information

LASERMET MINIATURE LED SIGN POWER AND SWITCH UNIT. Installation Instructions

LASERMET MINIATURE LED SIGN POWER AND SWITCH UNIT. Installation Instructions LASERMET MINIATURE LED SIGN POWER AND SWITCH UNIT Installation Instructions PS-LEDS-1W PS-LEDS-RG 00597-53-000 Issue 2 23 August 2010 Introduction The Miniature LED Sign Power and Switch Unit is intended

More information

EE042: Practical Power System Protection for Engineers & Technicians

EE042: Practical Power System Protection for Engineers & Technicians EE042: Practical Power System Protection for Engineers & Technicians EE042 Rev.001 CMCT COURSE OUTLINE Page 1 of 5 Training Description: This intensive course has been designed to give plant operators,

More information