ACO Marine product catalogue ACO Clara Waste water treatment plant Sizes 3-240
|
|
- Eileen Atkinson
- 6 years ago
- Views:
Transcription
1 ACO Marine product catalogue ACO Clara Waste water treatment plant Sizes 3-240
2 ACO CLARA ACO Clara Characteristics and application ACO Clara sewage treatment plants are designed for the complete biological purification of domestic waste water: Singlehouses Residential areas Hotels Boardinghouses Companies, etc. ACO Clara sewage treatment plants comply with all the requirements of EN , which is proven by a certificate. Treatment process Mechanical pre-treatment Biological treatment by activated sludge Final gravity sedimentation Efficiency of purification The following average values of effluents were achieved during tests in an accredited laboratory according to EN : BOD mg/l COD mg/l TSS mg/l N-NH mg/l Benefits Applications up tu load class D 400 Easy installation with no additional concreting Very stable and high treatment efficiency during irregular hydraulic and biological loads overload-resistant First-class electrical components Effective purification Low maintenance Low energy consumption Low costs for deep ground aplication Odour-proof access cover with smart construction High volume of storage tank blower air surplus sludge raw sewage water sludge return 2 Key: 1. Pre-treatment 2. Buffer area 3. Storage area 4. Activation tank 5. Final sedimentation tank
3 ACO Clara Technology description The ACO Clara sewage treatment plant consists of a mechanical pre-treatment part and a biological compartment. The biological part of the ACO Clara consists of an activation tank and a built-in final sedimentation tank. Surplus sludge is stored in the storage area, which in fully loaded plants is capable of holding about days capacity. The mechanical pre-treatment part is formed of a sedimentation tank with a high buffer area volume. The sewage water enters the ACO Clara unit via the inlet pipe and flows into the buffer area of the common buffer and storage tank. Settlable solids fall to the bottom of the tank and floating matter is caught by a scum board, thus protecting the raw sewage air lift pump against blockage. Hydraulic peaks at the inlet of ACO Clara sewage treatment plants are absorbed in the buffer area. The pre-treated water is then pumped at a uniform flow rate from the buffer area into the biological part of the plant. Hydraulic peak equalising considerably increases the stable purification efficiency. The activation tank is aerated by micro-bubble aeration. The water goes from the activation tank into the final sedimentation tank, which enables treated water to be separated gravitationally from activated sludge. The treated water flows out of the sewage treatment plant through the outlet connection. The activated sludge falls to the bottom of the final sedimentation tank, from where it is pumped back as return sludge and also partly into the storage area as surplus sludge. The final sedimentation tank is optionally equipped with a skimmer for the automatic collection and removal of floating sludge from the water surface. This device can reduce maintenance work during operation. The pumping of sewage water and return and surplus sludge is achieved using air lifts in the ACO Clara. These air lifts need no maintenance and are resistant to clogging. The hydraulic capacity of the air lifts is continuously adjustable, even at very low flow rates. This helps to ensure a uniform purification process and thus achieve stable purification efficiency. Air Connection Air Jet Air-lift Pump Final Sedimentation Tank Ventilation Pipe Inlet Pipe Outlet Unit 3 Activation Tank Pre-treatment Tank Microbubble Aeration Elements
4 ACO CLARA ACO Clara Standard/Light ACO Clara Standard ACO Clara Standard Weight [kg] Article number ACO Clara Light 4 ACO Clara Light Weight [kg] Article number
5 ACO Clara Standard/Light ACO Clara 3 29 Sizing, hydraulic and biological capacity ACO Clara Nominal size in PE Nominal hydraulic load [m 3 /day] Nominal biological load BOD 5 [kg/day] Range of usage Number of persons Hydraulic load [m 3 /day] Biological load BOD 5 [kg/day] Air supply pipe H1 H3 H2 H H4 Ventilation DN100 Inlet DN150 Outlet DN150 W L D Technical data ACO Clara Diameter D [mm] Lenght L [mm] Width W [mm] Height H [mm] Heght of inlet pipe H1 [mm] Heght of outlet pipe H2 [mm] Depth of water level H3 [mm] Height of ventilation pipe H4 [mm] Power supply [V/Hz] 230/50 230/50 230/50 230/50 230/50 Pover input [kw]
6 ACO CLARA ACO Clara Standard/Light ACO Clara Sizing, hydraulic and biological capacity ACO Clara Nominal size in PE Nominal hydraulic load [m 3 /day] Nominal biological load BOD 5 [kg/day] Range of usage Number of persons Hydraulic load [m 3 /day] Biological load BOD 5 [kg/day] Air supply pipe H H3 H1 H4 H2 Inlet DN200 Ventilation DN100 Outlet DN 200 L x W Technical data ACO Clara Lenght L [mm] Width W [mm] Height H [mm] Heght of inlet pipe H1 [mm] Heght of outlet pipe H2 [mm] Depth of water level H3 [mm] Height of ventilation pipe H4 [mm] Power supply [V/Hz] 230/50 230/50 400/50 400/50 400/50 400/50 Pover input [kw]
7 ACO Clara Standard/Light Adapters of ACO Clara Increasing the installation depth is possible without any expensive construction work. The main tanks of the AC Clara can be extended with adapters, enabling the height of the main tank to be increased quickly and easily. The access cover(s) is (are) identical, either for use with the main tank or with the adapter(s). The adapter position is secured by screws. The usage of two adapters with different heights which can be used separately or together makes possible height adjustment in a range of multiples of 100 mm. 7 ACO Clara L100 L250 L500 Height H [mm] Weight [kg] Article number L100 L250 L500
8 ACO CLARA ACO Clara Home / Home Concrete ACO Clara Home Sizing, hydraulic and biological capacity ACO Clara Home Nominal size in PE 4 8 Nominal hydraulic load [m 3 /day] Nominal biological load BOD 5 [kg/day] Range of usage Number of persons Hydraulic load [m 3 /day] Biological load BOD 5 [kg/day] Technical data ACO Clara Home Diameter D [mm] Height H [mm] Weight [kg] Power supply [V/Hz] 230/50 230/50 Pover input [kw] Article number ACO Clara Home Concrete Sizing, hydraulic and biological capacity ACO Clara Home C Nominal size in PE 4 8 Nominal hydraulic load [m 3 /day] Nominal biological load BOD 5 [kg/day] Range of usage Number of persons Hydraulic load [m 3 /day] Biological load BOD 5 [kg/day] Technical data ACO Clara Home C Diameter D [mm] Height H [mm] Weight [kg] Power supply [V/Hz] 230/50 230/50 Pover input [kw] Article number
9 ACO Clara Concrete ACO Clara Concrete Sizing, hydraulic capacity, technical data ACO Clara C Nominal size in PE Nominal hydraulic load [m 3 /day] Nominal biological load BOD 5 [kg/day] Range of usage Number of persons Hydraulic load [m 3 /day] Biological load BOD 5 [kg/day] ACO Clara C Diameter D [mm] Height H [mm] Number of tanks Weight [kg] Power supply [V/Hz] 230/50 230/50 230/50 400/50 400/50 400/50 400/50 400/50 Automatic removing of surplus sludge no no no no yes yes yes yes Pover input [kw] Art. Nr. standard cover Art. Nr. adjustable version Art. Nr. standard cover automatic Art. Nr. adjustable version automatic Air-lift Pump Air Sorter Final Sedimentation Tank 9 Pre-treatment Tank Aktivation Tank Microbubble Aretation Elements
10 ACO CLARA ACO Clara Concrete Sizing - instalation Legend: storage / buffer tank denitrification activation tank final sedimentation tank
11 ACO Clara Season ACO Clara Season ACO Clara Season is based on the Clara Plastic/Concrete technology and it is designed for all applications with big differences in the loading during a year when the biological load is too low to be able to feed the activation of a standard unit in the out-of-season period. These applications can be hotels at the seaside, hotel resorts, or hotels in the mountains as well as schools, cottage areas, and summer camps. ACO Clara Season is going to be always designed by ACO Clara team individually according to: Maximal hydraulic and biological load in full season period Minimal hydraulic and biological load out of season period Characteristic of the period between periods ACO Clara Season waste water treatment plants can operate in several operating modes. 1. ACO Clara S Full mode, all activation tanks are in use (loading PE) ACO Clara S One tank is out of use (loading PE) 3. ACO Clara S Only one tank is in use (loading PE)
12 ACO CLARA ACO Clara Concrete Technical parts Type d x h Weght Art. Nr. Picture Support and Shaft ring DN600 as per DIN4034 T1 Shaft ring DN800 as per DIN4034 T1 Shaft ring DN1000 as per DIN4034 T1 625 x x x x x x x x x x x x x x x x x Type d x D Weght Art. Nr. Picture Reduction plate x , x , x , x , 2591 Cover plate 12 DN1000 x , 1061 Foam for sealing of cover plate and shaft rings BEGU D400 loose BEGU D400, fixed, foul air save BEGU D125 loose BEGU D125, fixed, foul air save BEGU D400 DN800 loose
13 ACO Clara Concrete Technical parts Manhole covers BEGU - DN600, DN800 Support and Shaft rings - DN600, DN800 (height: mm) Cover plate Shaft ring - Ø mm (height: 250, 500, mm) Reduction plate ØDN1200/1 000 mm ØDN1500/1 000 mm ØDN2000/1 000 mm ØDN2500/1 000 mm Lower part 13 DN1000 mm (Ø 1 240) DN1200, 1500, 2000, 2500 mm (Ø 1 470, 1 800, 2 300, 2 800) DN1500, , 2500 mm (Ø 1 800, 2 440, 2 300, 2 800) with cover DN800 DN2200 mm (Ø 2 440) with cover DN600 DN2200 mm (Ø 2 440)
14 ACO CLARA Installation depth The ACO Clara waste water treatment plants are designed as a self-supporting plastic/concrete tank for installation in a ground bed without any concrete encasement up to depth of inlet pipe 4 m. The static resistance against ground pressure is depend on a type and size of the of the ACO Clara unit. The concrete encasement shall be carried on in cases if the depth of inlet pipe is higher than Hmax. ACO Clara Standard ACO Clara Light ACO Clara Concrete Hmax [m] ACO Clara Standard N/A N/A Light 0.9 Always use concrete N/A N/A Concrete Hmax Inlet pipe Outlet pipe 14
15 Additional equipment Automatic removing of surplus sludge To reduce the amount of maintenance work it is possible to equip the ACO Clara with a control unit which enables surplus sludge to be removed automatically and floating sludge in the final sedimentation tank to be removed automatically. ACO Clara Standard Automatic Article number ACO Clara Concrete Automatic Article number standard cover automatic as standard as standard as standard as standard Article number adjustable version automatic as standard as standard as standard as standard Box for outside installation of blower. ACO Clara AC 3-6 AC 5-10 AC 7-14 AC AC AC AC AC AC AC AC AC AC Weight [kg] Article number Box for outdoor installation of the blower Wherever the blower cannot be installed in a utility room of a building (garage, etc.), we offer robust plastic or concrete boxes for outdoor installation of the blower without any risk of damage, overheating, or theft. Boxes can be designed both for aboveground and underground installation. Sand filtration final treatment For all applications that put special emphasis on the quality of treated water, the technological line can be equipped with fully automatic sand filtration. START Pack If the plant cannot be filled with activated sludge upon start-up, we recommend using the START Pack, which contains substances that support fast formation of organic components in the plant, which significantly speeds up the initiation of the treatment process. When added regularly, it helps to keep the biological system of the wastewater treatment plant in excellent condition.
16 Head Office ACO Marine s.r.o. Nadrazni 72 CZ Praha 5 Czech Republic Tel.: Fax: acomarine@acomarine.com August 2015 ACO Marine. All reasonable care has been taken in compiling the information in this document. All recommendations and suggestions on the use of ACO products are made without guarantee since the conditions of use are beyond the control of the Company. It is the customer s responsibility to ensure that each product is fit for its intended purpose and that the actual conditions of use are suitable. This brochure and any advice is provided by ACO Marine free of charge and accordingly on terms that no liability (including liability for negligence) will attach the Company or its servants or agents arising out of or in connection with or in relation to this brochure or any such advice. Any goods supplied by the Company will be supplied solely upon its standard conditions of sale, copies of which are available on request. The Company s policy of continuous product development and improvement renders specifications liable to modification. Information provided in this brochure is therefore subject to change without prior notification. ACO Marine Clara 3-240/En/15/JMa Subject to technical changes without notice
ACO product catalogue ACO GRP Grease Separators ACO Lipumax-G
ACO product catalogue ACO GRP Grease Separators ACO Lipumax-G ACO. The future of drainage. Glass Fibre Grease Separators Lipumax-G collect: Collect and remove clean: Pre-clean and process hold: Protect
More informationACO product catalogue ACO GRP Light Oil Separators ACO Oleopator-G
ACO product catalogue ACO GRP Light Oil Separators ACO Oleopator-G ACO. The future of drainage. Glass Fibre Light Oil Separators Oleopator-G collect: Collect and remove clean: Pre-clean and process hold:
More informationACO product catalogue ACO GRP Light Oil Separators ACO Oleopator Bypass G
ACO product catalogue ACO GRP Light Oil Separators ACO Oleopator Bypass G ACO. The future of drainage Glass Fibre Light Oil Separators Oleopator Bypass G collect: Collect and remove clean: Pre-clean and
More informationACO product catalogue ACO GRP Sludge Trap G-H
ACO product catalogue ACO GRP Sludge Trap G-H ACO. The future of drainage Glass Fibre Sludge Trap G-H collect: Collect and remove clean: Pre-clean and process hold: Protect and attenuate release: Pump,
More informationACO product catalogue ACO GRP Light Oil Separators ACO Oleopator G
ACO product catalogue ACO GRP Light Oil Separators ACO Oleopator G ACO. The future of drainage Glass Fibre Light Oil Separators Oleopator G collect: Collect and remove clean: Pre-clean and process hold:
More informationACO product catalogue ACO GRP (Glass Reinforced Plastic) Separators Grease & Light Oil Separators Sludge Trap
ACO product catalogue ACO GRP (Glass Reinforced Plastic) Separators Grease & Light Oil Separators Sludge Trap ACO. The future of drainage GRP (Glass Reinforced Plastic) Separators Grease & Light Oil Separators
More informationDecember Labko BioKem Wastewater Treatment Plants. Product brochure BATCH REACTORS FOR PROCESSING WASTEWATER OF 6-90 PERSONS
December 2006 Labko BioKem Wastewater Treatment Plants Product brochure BATCH REACTORS FOR PROCESSING WASTEWATER OF 6-90 PERSONS Reliable solutions Wastewater treatment systems Labko BioKem Batch Reactors
More informationDELPHIN cube. Reliable process Strong tanks Clever modules. Compact biological wastewater treatment plants with fixed-bed technology
DELPHIN cube Compact biological wastewater treatment plants with fixed-bed technology DELPHIN Water Systems GmbH & Co. KG The experts for fixed-bed technology Modular system for decentralized wastewater
More informationEPIC J3413. Uniclass L L2123. CI/SfB (52.5) In6. The most advanced drainage system of its kind. ACO Qmax. Technical Data
Uniclass L7315 + L2123 EPIC J3413 CI/SfB (52.5) In6 The most advanced drainage system of its kind ACO Qmax Technical Data ACO Qmax System Contents Load Classes 3 ACO Qmax 600 System Pedestrian and Car
More informationUniclass L L2123 EPIC J3413. CI/SfB (52.5) If9. Surface drainage for heavy duty traffic applications ACO RoadDrain
Uniclass L7315 + L2123 EPIC J3413 CI/SfB (52.5) If9 Surface drainage for heavy duty traffic applications ACO RoadDrain ACO RoadDrain CHANNEL DRAINS Load Class (BS EN 1433:2002) Optimum solution ACO RoadDrain
More informationSeparators. The new rotomoulded tank system ACO Grease, starch and light liquid separators for below ground installation
he new rotomoulded tank system ACO Grease, starch and light liquid separators for below ground installation ACO Grease, starch and light liquid separators for below ground installation Commercial operations
More informationBrief Description SOLIDO. Fully biological SBR Small Wastewater Treatment Plant for 2 32 PE according to EN
Brief Description SOLIDO Fully biological SBR Small Wastewater Treatment Plant for 2 32 PE according to EN 12566-3 REWATEC GmbH Bei der neuen Münze 11 22145 Hamburg Germany Telephonic expertise: 0049-30-44
More informationACO Marine product catalogue ACO GM-X and GM-X-VACplus drainage pipes and steel fittings for the marine industry
ACO Marine product catalogue ACO and -VACplus drainage pipes and steel fittings for the marine industry ACO and -VAC Table of Contents Steel drain pipes and fittings 40-250 EN 1123 ACO Marine, as a division
More informationSEPTIC TANKS. Round septic tanks. Standard version ECO version. Rectangular septic tanks. ECO version
SEPTIC TANKS Round septic tanks Standard version ECO version Rectangular septic tanks Standard version ECO version Reinforced vertical septic tanks Reinforced horizontal septic tanks Grease traps for private
More informationHYDROCARBON SEPARATORS
HYDROCARBON SEPARATORS Hydrocarbon separators class I in PE Standard version (to install in consolidated sand) Reinforced version (to install in sand) Without and with mud trap Hydrocarbon separators class
More informationACO Light liquid separator Oleopator P Class I. Oleopator P Order data. Light liquid separators
Light liquid separators ACO Light liquid separator Oleopator P Class I Light liquid separator of polyethylene for below ground installation according to EN 858 certificate 7310434-01 () 7310434-02 () 7310434-03
More informationACO Water Management: Civils + Infrastructure
ACO Water Management: Civils + Infrastructure Uniclass L2123 + L7315 CI/SfB (52.5) EPIC J3413 ACO MultiDrain MD ACO MultiDrain MD - channel drainage system Product Overview ACO MultiDrain MD System Product
More informationACO Drain. For more information on ACO Drain visit ACO KerbDrain 280 Splay
Uniclass L223 + L735 EPIC J343 ACO Drain ACO KerbDrain Splay CI/SfB (52.5) ACO KerbDrain Splay Kompact combined drainage and kerb system ACO KerbDrain Splay Product Overview Introduction to ACO KerbDrain
More informationDewatering Submersible sewage pumps
Series description Wilo-Drain TP 80/TP 100 Equipment/function Thermal motor monitoring Leakage detection in the motor ATEX-certified Sheath current cooling Materials Pump housing: PUR Impeller: PUR Shaft:
More informationSeparators. The new rotomoulded tank system ACO Grease, starch and light liquid separators for below ground installation
he new rotomoulded tank system ACO Grease, starch and light liquid separators for below ground installation ACO Grease, starch and light liquid separators for below ground installation Commercial operations
More informationGullies. Box - Gutters. Slot - Gutters. Grease Locks
Gullies Box - Gutters Slot - Gutters Grease Locks 1 for Food Processing Specifically tailored waste water systems Box Gutters Stainless steel 1.4301. These time-tested models are available in two widths
More informationMultilift M, MD, MDV, and MD1 ranges
Multilift_front.qxd 19-05-2006 13:32 Side 1 GRUNDFOS WASTEWATER Multilift M, MD, MDV, and MD1 ranges 303_616_br_lifting_uk.qxd 22/02/05 8:46 Side 2 Grundfos Lifting Stations Reduced costs and optimised
More informationWSB clean: Installation Manual
WSB clean: Installation Manual Models: WSB 400 WSB 1250 WSB 500 WSB 1500 WSB 600 WSB 1600 WSB 750 WSB 1800 WSB 1000 TABLE OF CONTENTS 1 INTRODUCTION...3 2 SAFETY INFORMATION...3 3 WSB CLEAN SYSTEM OPERATION...4
More informationThe new rotomoulded tank system ACO Grease and light liquid separators for below ground installation
he new rotomoulded tank system ACO Grease and light liquid separators for below ground installation ACO Light liquid separator Oleopator P Class I Light liquid separator of polyethylene for below ground
More informationSludge Management EENV Overview of Sludge Treatment & Disposal
Sludge Management EENV 5000 Overview of Sludge Treatment & Disposal Sludge Management Highly complex and costly Has a cost ranging from 20% to 60% of the total operating costs of the wastewater treatment
More informationLOW OPERATING COST LOW START-UP COST. Media TM has its own built-in. the initial savings over new mechanical
. ... LOW OPERATING COST What could be more efficient than Merit Filter Media TM? There are no mechanical parts to break down, minimal maintenance requirements and there is no power source needed other
More informationJUNG PUMPEN COMPLI 1500 / 2500 SEWAGE LIFTING STATIONS
APPLICATION The compli 1500 and 2500 tank systems have been designed for large industrial and communal wastewater volumes as well as for the connection of streets or other community effluent systems. In
More informationReverse Osmosis (RO) Water Treatment Systems
Reverse Osmosis (RO) Water Treatment Systems Commercial and Industrial RO Systems & Components Table of Contents Packaged Reverse Osmosis Water Treatment Systems....3 Small Size RO System.... 4 LPRO-16
More informationROTAMAT Sludge Acceptance Plant Ro 3
ROTAMAT Sludge Acceptance Plant Ro 3 with integrated screenings washing and pressing The Quality Company Worldwide HUBER provides complete systems and processes for septic sludge treatment. Our equipment,
More informationThe City of Sturgis Wastewater Treatment Plant Septage Waste Receiving Facility Operating Plan
The City of Sturgis Wastewater Treatment Plant Septage Waste Receiving Facility Operating Plan Introduction/Purpose: The City of Sturgis Wastewater Treatment Plant is owned and operated by the City of
More informationStone Food Machinery Ltd 14 North Main Street Wexford IRELAND Tel
Stone Food Machinery Ltd 14 North Main Street Wexford IRELAND E-mail: info@stonefoodmachinery.com WWW.STONEFOODMACHINERY.COM Tel- +353 53 9147800 Copyright 2008 1 Overview of Volute Dewatering Press Flow
More informationThe New Generation in Decentralised Wastewater Treatment. State of the Art SBR-Treatment. Compact and efficient, simple to install
State of the Art SBR-Treatment Compact and efficient, simple to install High and reliable quality Made in Germany Easier is better! The New Generation in Decentralised Wastewater Treatment How it works
More informationALLWEILER. Block Macerators Series ABM Designs S and I. Design I with controller and seal water unit
Block Macerators Series ABM Designs S and I Design S Design I with controller and seal water unit Usage Macerators chop solids conveyed in liquids; materials like wood, textiles, plastics, paper, rubber,
More informationWASH SYSTEM. Instructions for Use
WASH SYSTEM Instructions for Use COMPONENTS LIST THESE SYSTEMS MUST BE CORRECTLY INSTALLED IN ACCORDANCE WITH REQUIREMENTS OF REGULATORY WATER AUTHORITY PRIOR TO USE Pre-Filter / Release Valve Outlet Water
More informationquickone+ aerated cabinet clearwater sampling backflush HQ membranes installation weight single chamber SBR KIT
quickone+ single chamber SBR KIT aerated cabinet clearwater sampling backflush HQ membranes installation weight one KIT for ALL TANKS with or without baffle wall delivery installation 30 min ready sludge
More informationJUNG PUMPEN COMPLI 100 MC SEWAGE LIFTING STATIONS
APPLICATION The sewage lifting stations compli 100, compli 500 and compli 1000 with MultiCut cutting system are uses especially for disposal in special objects, such as weekend cottages, houseboats, toilets
More informationABS lifting station Synconta
15975187GB (03/2006) 106800 GB Installation and Operating Instructions www.absgroup.com Installation and Operating Instructions 601 801 901 901L 902 902L Contents 1 General... 3 1.1 Application areas...
More informationAppendix B-6. Mechanical Equipment Design Calculation
Appendix B-6 Mechanical Equipment Design Calculation APPENDIX B.6 Mechanical Equipment Calculation (1) Design Flow 1. Design Conditions M3/day M3/hour M3/min M3/sec Design Maximum Daily Flow Design Maximum
More informationSewage transport Submersible pumps
Series description Wilo-Rexa FIT Available from January 2012 Construction Submersible sewage pump with cast iron hydraulics and stainless steel motor Type key Example: Wilo Rexa FIT V06DA-110/EAD1-2-T0015-540-A
More informationRESOLUTION MEPC.205(62) Adopted on 15 July GUIDELINES AND SPECIFICATIONS FOR ADD-ON EQUIPMENT FOR UPGRADING RESOLUTION
MEPC.60(33)-COMPLIANT OIL FILTERING EQUIPMENT MEPC.60(33)-COMPLIANT OIL FILTERING EQUIPMENT MEPC 62/24/Add.1 Annex 24, page 1 ANNEX 24 RESOLUTION MEPC.205(62) 2011 GUIDELINES AND SPECIFICATIONS FOR ADD-ON
More informationwipes ready technology
MUFFIN MONSTER 1K series Muffin Monster The 1K Series Muffin Monster is a compact grinder, tough on solids in sludge and sewage applications. It fits into areas with limited space requirements while still
More informationRAS & WAS Pumps (FLYGT Pump)
RAS/WAS Pumping Pumping of sludge from the secondary clarifiers to the aeration tanks maintains active biomass in the aeration tanks This is referred to as return activated sludge (RAS) pumping RAS pumps
More informationJUNG PUMPEN compli 100 MC Sewage lifting stations
Application The sewage lifting stations compli 100, compli 500 and compli 1000 with MultiCut cutting system are uses especially for disposal in special objects, such as weekend cottages, houseboats, toilets
More informationGRUNDFOS DATA BOOKLET AP, KP. Wastwater pumps 50 Hz
GRUNDFOS DATA BOOKLET AP, KP Wastwater pumps 5 z Contents General data Performance range Page 3 Applications Page 5 Examples of application Page 5 Pump overview Page 6 Type key for AP pumps Page 6 Type
More informationSludge Thickening. Wastewater Treatment Review. Gravity Thickening
Wastewater Treatment Review 10 Sludge Thickening nw ate rc oll e ge 20 Gravity Thickening ca Principle of Operation 1. Uses gravitational forces to separate water from sludge 2. Solids settle to bottom
More informationGRUNDFOS WASTEWATER. S range kw. 50 and 60 Hz versions
GRUNDFOS WASTEWATER S range 1.65 5.0 kw 50 and 60 Hz versions Grundfos Powerful pumps for handling unscreened raw sewage Grundfos offers a complete range of highly dependable, powerful sewage pumps, designed
More informationCo-treatment of Septage with Municipal Wastewater in Medium Sized Cities in Vietnam
Co-treatment of Septage with Municipal Wastewater in Medium Sized Cities in Vietnam David Robbins Sher Singh PE, Ross Kearton SCE Aménagement & Environnement for Cities Development Initiative for Asia
More informationVALVOLINE HYDRAULIC OILS PEOPLE WHO KNOW USE VALVOLINE
VALVOLINE HYDRAULIC OILS PEOPLE WHO KNOW USE VALVOLINE VALVOLINE I HYDRAULIC OILS TOGETHER, STRONGER! First brand - First in innovation Dr. John Ellis created the petroleum industry s first brand in 1866.
More informationSUBMERSIBLE DIRTY WATER PUMP
FOR USE WITH A 110V SUPPLY ONLY SUBMERSIBLE DIRTY WATER PUMP MODEL NO: DWP210A PART NO: 7230102 OPERATION & MAINTENANCE INSTRUCTIONS LS0115 INTRODUCTION Thank you for purchasing this CLARKE Submersible
More informationAqualift F XL Lifting Stations
Aqualift F XL Lifting Stations For industrial / high volume wastewater disposal Leading in Drainage Product Information Applications For use with wastewater from commercial, public and private sources
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS EARTHSAFE D10 WASTEWATER TREATMENT SYSTEM A. PREPARING THE SITE INSTALLATION SUGGESTIONS See if you can site the tanks away from commonly used vehicular access, and also away
More informationFight F.O.G. with AMA-GREASE Separator System Solutions
Our technology. Your success. Pumps n Valves n Service Fight F.O.G. with AMA-GREASE Separator System Solutions 02 Introduction Customisable Two-Compartment Stainless Steel Sludge and Grease Separator System
More informationSpecifications
Specifications 15 Year Warranty Seamless Rotationally-Molded Shell 0.150 Nominal Wall Thickness EPS Foam Filled Flash Dot ACOE Approved Tank Tested Buoyancy Ratings +0/-5% 800-531-4734 www.cellofoam.com
More informationACO Water Management: Civils + Infrastructure
ACO Water Management: Civils + Infrastructure Uniclass JR12/JR23 L731 CI/SfB (52.7) ACO Q-Brake Vortex Vortex flow controls ACO Q-Brake Vortex Introduction to the ACO Group Throughout the world, the ACO
More informationInstruction Manual. Sewage lifting station compli 300
Instruction Manual Sewage lifting station compli 300 Safety instructions Areas of application Electrical connection Installation Servicing Technical data Appendix JUNG PUMPEN GmbH Industriestr. 4-6 33803
More informationSmart Battery Charger GPC-35-MAX GPC-45-MAX GPC-55-MAX GPC-75-MAX GPC-100-MAX. Owner s Manual
Smart Battery Charger GPC-35-MAX GPC-45-MAX GPC-55-MAX GPC-75-MAX GPC-100-MAX Owner s Manual Table of Contents Important Safety Instructions 2 Features 3 Installation Guidelines 5 Warranty 8 1.0 Important
More informationACO Marine. ACO Marine. Complete Wastewater Management. Advanced wastewater solutions for the luxury super & mega yacht markets
ACO Marine Advanced wastewater solutions for the luxury super & mega yacht markets ACO Marine Complete Wastewater Management The Carlshütte iron foundry Captain Otto Friedrich Ahlmann Käte Ahlmann (1890-1963)
More informationELECTRIC SUBMERSIBLE PUMPS SEMISOM/80
Electric pumps for professional applications to convey sewage water, entirely designed and manufactured in our Italian facility. APPLICATION PERFORMANCE RANGE To convey waste and sewage water from septic
More informationSUBMERSIBLE PUMP RANGE
SUBMERSIBLE PUMP RANGE www.vegapumps.co.za INDEX VXM / VX SUBMERSIBLE PUMP... 4 PERFORMANCE DATA... 5 V RANGE SCREENED SWAGE SUBMERSIBLE PUMP... 6 PERFORMANCE DATA... 7 DIMENSIONAL DRAWING... 9 C-SERIES
More informationAmerican Water College 2010
Vocabulary Primary Treatment (Sedimentation/Flotation) Preliminary Treatment The removal of metal, rocks, rags, sand, eggshells, and similar materials which may hinder the operation of a treatment plant.
More informationThe Pump Matic Range
The Below Ground packaged pumping Stations Ideal for - Sewage, Wastewater, Stormwater Pump Technology Ltd, manufactures its own pumping station tanks. We have complete control over the construction, quality
More informationHampton Roads Planning District Commission
Hampton Roads Planning District Commission OBJECTIVE To help Grease Haulers comply with the Regional Consent Order and ensure proper maintenance of grease control devices. BACKGROUND In 2007, Special Orders
More informationNational/scandinavian requirements for septic tanks
National/scandinavian requirements for septic tanks Rørcentret Inge Faldager Teknologisk Institut Fred Nyberg, Nafal AB CEN TC 165 / WG 41 Small wastewater treatment systems < 50 PT Overview A 1 or 4 2
More informationAries Technical Information. Features and Benefits. Integral dripper
Aries Integral dripper 12010-16009 - 16010-16012 - 20010-20012 Technical Information Deciduous and tree irrigation. On-surface multi seasonal row crops. Specifications Maximum system pressure: according
More information(a) Administrator means Clearwater's Public Works Administrator or his or her designee.
Sec. 32.189. Grease prevention program. (1) Definitions. Unless a provision of this section explicitly states otherwise, the following terms and phrases, as used in this section, shall have the meanings
More informationSIR INTERMEDIATE LIFTING STATIONS Communal waste water 50 Hz. operating limits. Useful volume up to : S.I.R. 2500
operating limits Useful volume up to : S.I.R. 5 S.I.R. 5 97 L 9 L Ambient temperature : to + 5 C Max.fluid temperature : Particle size passing : 35 C* Ø and mm ND Ø Inlet : mm** Ø Outlet : Ø Vent : mm**
More informationOPERATION & MAINTENANCE INSTRUCTIONS
750W SUBMERSIBLE PUMP WITH BUILT-IN FLOAT SWITCH MODEL NO: PSV5A PART NO: 7236046 OPERATION & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS LS0917 iss 3 INTRODUCTION Thank you for purchasing this CLARKE
More informationUSER S MANUAL FOR F & Q. Submersible Sewage Pumps
USER S MANUAL FOR F & Q Submersible Sewage Pumps 100WQ Series The F&Q pumps are carefully inspected and tested to ensure operating performance and safety. However, failure to follow the instructions and
More informationSewerage Services.
Sewerage Services jballosewage@gmail.com www.jballosewage.com JB ALLO SEWAGE The experience you need and quality you deserve Pumping Services Grease Trap Sump Pit Lift Station Septic Tank Sewage Tank Holding
More informationSE M.C.N.51D
GRUNDFOS DATA BOOKLET SE1.110.200.200.4.52M.C.N.51D Grundfos pump 98179813 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/seslfam/98179813/se1-110-200-200-4-52m-c-n-51d.html
More informationIntroduction. Introduction. Introduction. Sludge handling in small and mid-size treatment plants. - Introduction
Sludge handling in small and mid-size treatment plants Dr.-Ing. Jörn Einfeldt (Privatinstitut für Klärtechnik GmbH, D-23611 Bad Schwartau, Germany) - - Case Examples: Small Treatment Plants (i.e. WWTPs
More informationCity of Marlette. Wastewater Treatment Facility. Septage Receiving Plan
City of Marlette Wastewater Treatment Facility Septage Receiving Plan Introduction Part 117, Septage Waste Servicers, of the Natural Resources and Environmental Protection Act, 1994 PA 451, regulates the
More informationSeptage Treatment at Small Wastewater Treatment Plants
Septage Treatment at Small Wastewater Treatment Plants Khamis Al-Omari Omari,, Hazen and Sawyer, P.C. 2008 MWEA Annual Conference (Session 3) Boyne Mountain Resort Boyne Falls, Michigan June 23, 2008 Acknowledgements
More informationSeparators. industrieblick Fotolia.com. For indoor or below ground installation ACO Light Oil Separators Coalisator-P
Separators industrieblick Fotolia.com For indoor or below ground installation ACO Light Oil Separators Coalisator-P Light Oil Separators Application If mineral oils or light oils, especially those that
More informationCone Skimmers. Instructions. for Models 75G, 150G and 300G. Please read these instructions in their entirety before attempting to use this product.
Cone Skimmers Instructions for Models 75G, 150G and 300G Please read these instructions in their entirety before attempting to use this product. The pumps used with the Coralife 75G, 150G and 300G Cone
More informationSUBMERSIBLE WATER PUMP
SUBMERSIBLE WATER PUMP MODEL No: IVP14A Part No: 7230095 OPERATION & MAINTENANCE INSTRUCTIONS 08/08 INTRODUCTION Thank you for purchasing this CLARKE water pump. This highly efficient centrifugal pump
More informationHAWLE-AIR RELEASE VALVES
HAWLE-AIR RELEASE VALVES HAWLE-AIR RELEASE VALVES Contents: Dimensions of Air Release Valve Page 2 Why use Air Release Valves? Page 3 Application: Potable water Air Release Valves, DN 1" - DN 2" Page 4
More informationSeries 95/96 upvc Valves
Series 95/96 upvc Valves Product Catalogue Series 96/95 Valves Series 96/95 upvc Valves Catalogue Plastic Valves Dorot Control Valves is a world leader in the development and supply of sustainable technologies
More informationSEV D. Grundfos Pump GRUNDFOS DATA BOOKLET
GRUNDFOS DATA BOOKLET SEV.6.6...1D Grundfos Pump 96779 Thank you for your interest in our products Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/sev/96779/sev-6-6---1d.html
More informationSUBMERSIBLE WATER PUMP
SUBMERSIBLE WATER PUMP MODEL NO: CSV1A, CSV2A PART NO: 7230582, 7230602 OPERATION & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS 05/14 iss 4 INTRODUCTION Thank you for purchasing this CLARKE Submersible
More informationReliable backwater protection. Protection from backwater. Backwater protection for interior installation
Reliable backwater protection Protection from backwater Backwater Protection - things you need to know Prevention Not properly protecting a building against backwater can result in damage that is extremely
More informationIMPLEMENTING A WASTEWATER TREATMENT FACILITY UPGRADE/ EXPANSION USING IFAS AT WEST HAVEN, CT
28 January 2015 IMPLEMENTING A WASTEWATER TREATMENT FACILITY UPGRADE/ EXPANSION USING IFAS AT WEST HAVEN, CT MARIO FRANCUCCI AGENDA Design Basis Project Challenges ConstrucEon Sequences and RestricEons
More informationSpin Klin 3"-4" Apollo Angle
Spin Klin 3"-4" Apollo Angle w w w. a r k a l - f i l t e r s. c o m 3"-4" Spin Klin Angle Apollo Battery Service & Maintenance Manual Table of Contents Subject Page No. 1. Introduction... 3 2. Safety
More informationINSTALLATION AND OPERATING INSTRUCTIONS FOR CONCRETE VAULT TYPE UNITS
INSTALLATION AND OPERATING INSTRUCTIONS FOR CONCRETE VAULT TYPE UNITS CONTENTS Introduction Safety Operating Principle System Installation Initial Startup System Operations Troubleshooting Maintenance
More informationUSER S MANUAL FOR F & Q. Submersible Sewage Pumps
USER S MANUAL FOR F & Q Submersible Sewage Pumps 50WQ Series The F&Q pumps are carefully inspected and tested to ensure operating performance and safety. However, failure to follow the instructions and
More informationSPIRAL. finned tube radiators
SPIRAL finned tube radiators ABOUT THE COMPANY CONTENTS ISAN is a traditional supplier with more than 50 years of experience in providing its customers with bathroom outfitting, such as the ISAN MELODY
More informationMECHANICAL MACHINING MINIPURE STATION FOR THE TREATMENT OF CUTTING AND PROCESS FLUIDS.
MINIPURE STATION FOR THE TREATMENT OF CUTTING AND PROCESS FLUIDS Machining of aluminium, copper, cast iron and steels Machining of plastics and composite materials Deep hole drilling Spark machining Vibratory
More informationThe 2600 dewatering pump series. The new force in dewatering
The 26 dewatering pump series The new force in dewatering The new force in dewatering unbeatable in tough environments The 26 series from Flygt represents a major breakthrough in dewatering pump technology.
More informationMIZU QUICK CHANGE DUAL FILTER SYSTEM
QUICK CHANGE DUAL FILTER SYSTEM page 1 of 5 130mm 290mm 70mm 380mm 100mm (filter unit depth) 180mm Dimensions are nominal measurements only. 1. 3/4 Multifunction valve 2. Filter isolating valve 3. 90 deg
More informationSLR / SLR-S/N. Instruction Manual. Walrus America Inc
SLR / SLR-S/N Instruction Manual Walrus America Inc 1. Installation and Connection 1.1. Pump Installation The pump should be sited in a well ventilated and frost-free position. The distance between pumps-motors
More informationPORTER TOWNSHIP CASS COUNTY, MICHIGAN PUBLIC WORKS SECTION PART 60 SEPTAGE RECEIVING ORDINANCE ORDINANCE #
PORTER TOWNSHIP CASS COUNTY, MICHIGAN PUBLIC WORKS SECTION PART 60 SEPTAGE RECEIVING ORDINANCE ORDINANCE # 8-02-11 An ordinance to provide for the disposal of septage waste at a licensed facility; authorize
More informationSequencing Batch Reactor. Maintenance Manual. Only modules bearing the NSF logo and designated PS1-XX are certified to NSF/ANSI Standards 40 and 245
Sequencing Batch Reactor Maintenance Manual Only modules bearing the NSF logo and designated PS1-XX are certified to NSF/ANSI Standards 40 and 245 2017 Anua 12-2017 Table of Contents Maintenance Manual
More informationCATALOGUE SEWAGE MANHOLES
CATALOGUE SC SEWAGE MANHOLES Table of contents TABLE OF CONTENTS Introduction 4 Inspection chamber, type 315 7 Inspection chamber, type 400 10 Inspection chamber, type 425 14 Assembly instruction 19 Catch
More informationRSR-KS ROTARY AIR BLOWERS
www.tsurumi-global.com RSR-KS ROTARY AIR BLOWERS Rotary Air Blowers Tsurumi's RSR-KS series rotary air blowers are equipped with a 3-lobe spur rotor. This rotor, as the most important component of a blower,
More informationINDUSTRIES INDUVENT. With the patented Teddington EVOLVENT Nozzle Technology.
INDUSTRIES INDUVENT With the patented Teddington EVOLVENT Nozzle Technology. Teddington INDUVENT The standard air curtain system for the industry... Compact, flexible, high performance. 2 Highly frequented
More informationVent-Axia Roof Units Range Energy Recovery Ventilation (ERV) Range
CI/SfB (57.7) 1st Edition from Vent-Axia Vent-Axia Roof Units Range Energy Recovery Ventilation (ERV) Range Energy Recovery Ventilation (ERV) Range Building on the success of the Sentinel Totus 2 range
More informationWatertreatment. Landbased Farming. Weedfilter. Catvis WATER I NTAKE R ECIRCULATION S YSTEM
Weeds Drum Cartridge UV-unit WATER I NTAKE Screen Pump Weed Drum UV-unit Climate control H ATCHERY N URSERY B ROODSTOCK O NGROWING Oxygen reactor Denitrification Control unit R ECIRCULATION S YSTEM Ozonation
More information1BGrease Traps and. Frequently Asked Questions About Grease:
0B 1BGrease Traps and Interceptors 112 W Washington Ave. Fergus Falls MN 56537 Building Department (218)332-5434 Frequently Asked Questions About Grease: Is grease a problem? What is a grease trap and
More informationThis document is a preview generated by EVS
EESTI STANDARD EVS-EN 12255-6:2002 Wastewater treatment plants - Part 6: Activated sludge processes Wastewater treatment plants - Part 6: Activated sludge processes EESTI STANDARDIKESKUS EESTI STANDARDI
More informationD-023 PN 16 / 25. Combination Air Valve for Wastewater PATENTED. Description. Applications. Operation. Main Features
PN 16 / 25 Wastewater Combination Air Valve for Wastewater PATENTED EuroC-D023SWG-15-2 Description The D-023 Combination Air Valve combines an air & vacuum component and an air release component in a single
More information