Brief Description SOLIDO. Fully biological SBR Small Wastewater Treatment Plant for 2 32 PE according to EN
|
|
- Aron Morrison
- 6 years ago
- Views:
Transcription
1 Brief Description SOLIDO Fully biological SBR Small Wastewater Treatment Plant for 2 32 PE according to EN REWATEC GmbH Bei der neuen Münze Hamburg Germany Telephonic expertise: (9-16 h) info@rewatec.de web: DOKK5201E KB SOLIDO engl. Seite 1 von 12
2 1. Brief Description General SBR-small Wastewater Treatment Plant (KKA) SOLIDO consists of highly resistant polyethylene plastic containers and work with the Sequencing Batch Reactor Process. It is available in several versions for 2 40 inhabitants. Approvals General technical approval from the German Institute for Civil Engineering (DIBt) for the effluent classes C, N and D. Cleaning category SOLIDO conforms to the cleaning category C, N and D (Carbon and Nitrogen degradation as well as additional denitrification) and can keep the following requirements: BOD 5 : 20 mg/l from a grab sample, homogenised COD: 90 mg/l from a grab sample, homogenised NH 4 -N: 10 mg/l from a 24 h composite sample, filtrated N anorg : 25 mg/l from a 24 h composite sample, filtrated Manufacturing SOLIDO is manufactured as a one-container plant with a separating wall or as a morecontainer plant. The containers are industrially made of highly resistant polyethylene (LLD-PE) in the rotation sintering process. Manufacturing enterprise is the ROTA GmbH, Am Gammgraben 2, D Boizenburg. Warranty 25 years manufacturer s warranty for containers, 3 years manufacturer s warranty for electrical units such as aerator, pumps and control with the correct operation and maintenance by a service partner authorised by REWATEC.. Mode of operation SOLIDO always has at least two separated chambers. The first acts as a sludge reservoir and buffer, in the second chamber the cleaning process takes place. The SBRsystem SOLIDO provides the oxygen supply of the microorganisms via a compressor and pipe shaped aerator. These microorganisms transform the contents of the wastewater into settleable activated sludge. The emerging excess sludge is pumped into the first chamber, during the treatment. The treatment takes place in batches, each cycle lasts 6 hours and is controlled by a programmable electronic control unit. The control unit allows to adapt the running operation times when the local conditions vary. The patented construction of the air lifters enables the system to do an automatic backflush before every start. A sludge loss or blocking of the charging lifter are avoided. Energy consumption The SBR-system SOLIDO has a compressor with an electrical power from 46 to 210 Watt (depending on the size of the plant), three solenoid valves, one control unit, as well an optional float switch (SOLIDO Sensor). Because of the efficient utilisation of the compressed air the energy consumption according to the desired decomposition rate and actual utilization is about 50 kwh per inhabitant and year for the effluent class C. This average cost is 13,50 per person/ year (with an electricity tariff of 0.27 /kwh). DOKK5201E KB SOLIDO engl. Seite 2 von 12
3 Holiday mode The control offers the possibility to enter the length of a holiday / absence for up to 30 days (savings mode). At the end of the entered time the control automatically returns again to the standard mode. Energy saving mode (at version SOLIDO Sensor with float switch) If no wastewater inflow takes place for a longer period, the aeration time is reduced automatically. With this energy saving mode, the microorganisms are kept alive even during holidays, and at the same time energy is saved. Maintenance and Sampling According to German Institute for Civil Engineering (DIBt) approval the SOLIDO plant has to be maintained twice a year. Within the maintenance the time of the sludge removal from the first chamber is fixed. This has to be carried out every 6-24 month, depending on the utilisation and the type series. The sampling is carried out by removing the content of the sample bottle. It is changed during the clearwater removal every 6 hours, so that a current sample is available any time. Installation notes The containers have to be installed in a sharp object free, shock-free trench, whose base has to be well compressed and level. For the installation, half fill the containers with water, coat them with proper material from all sides, with a thickness of cm and compact it in layers. The filling material has to be well compressible, permeable, shearing resistant and free from sharp objects (e.g. gravel sand with wide staged granulation). Concrete is not necessary. The installation is possible in a depth of groundand surface water of 1.00 m under ground, when the necessary height above ground is considered. The SBR-aggregate SOLIDO has to be connected by a plug-in cable (15 m or 30 m length) to the plant control. A duct pipe (DN70 DN100) should be installed for this purpose. The control unit has to be plugged into a socket with a separately secured ground fault circuit interrupter (30mA), with a working PE-conductor. Further information for the installation can be found in the installation guidelines for MONOLITH containers I and II. There is also information about the installation of drivable versions resp. the installation at high ground water levels (buoyancy protection, welding of shaft elements, rubber seals, etc.). Operator s duties Among the general duty of care such as the avoidance of the discharge of inappropriate substances, like chemicals resp. contraries of all kinds, the operator has to make sure that the plant is operating correctly. Visual inspections have to be carried out monthly and have to be noted in the operations logbook. The operating times of the plant are automatically saved in the operations logbook of the control unit. A written logbook is recommended and required by the water authorities! Approval A precondition for the operation of a small Wastewater Treatment Plant is obtaining the correct approvals from your local water authority and an acceptance / startup by a specialised company. DOKK5201E KB SOLIDO engl. Seite 3 von 12
4 2. Product Qualities SOLIDO compact: minimum required space with only two chambers, without separate final sedimentation quiet: no noise inside the house because of integrated technical capsule easy to assemble: all hoses and small parts are pre-mounted in the MONOLITH container only one pre-finished pipe between tank and house, no installation of complicated hose packages necessary Fail-safe: extremely robust and guaranteed single, one-piece container (can be installed in heavy grounds and high ground water up to 1.00 m) plug-proof compressed air lifter air lifters with a patented automatic backflush prevent sludge loss and improve the effluent qualitiy reliable, multiple proved control unit with integrated operations logbook + holiday mode easy: economical: light, rectangular container for an easy installation and handling integrated sample bottle, no separate sampling chamber necessary low energy consumption of only about 50 kwh/ew*a because of efficient utilisation of compressed air and adapted aeration * Measuring results test field PIA, Aachen 2012 DOKK5201E KB SOLIDO engl. Seite 4 von 12
5 3. One container systems 3.1 Main dimensions MONOLITH II DOKK5201E KB SOLIDO engl. Seite 5 von 12
6 3.2 Shaft system for MONOLITH II Shaft Elements cone + VS 20 Application area Walk-on version (standard scope of delivery) cone + spacer ring + VS 20 higher installation depth cone + VS 60 / BS 60 Car driveable (BS60) resp. with higher installation depth (VS60) cone + spacer ring Preparation lorry driveability spacer ring cone + VS 20 Spacious shaft element, higher installation depth NOTES: MONOLITH II containers have a inspection shaft DN and a shaft DN 200 for desludging, that is scope of delivery with a height of 620 mm. Extensions DN 200 or drivable covers must be applied onsite. The inspection shaft plants can be shortened in the standard version up to 12 PE to about max. 14 cm! With lower installation depths an alternative siting of the technical capsule can be achieved e.g. in a separate capsule shaft. All given measurements with range of variation show the possible installation depth given by telescopic pushing of the respective shaft elements. spacer ring cone + VS 60 / BS 60 Spacious shaft element, higher installation depth 3.3 SOLIDO 5 E-35-II as walk-on standard version with cone and VS20 DOKK5201E KB SOLIDO engl. Seite 6 von 12
7 3.4 SOLIDO for deeper installation (cone + spacer ring VS 20) 3.5 SOLIDO 5 E-35-II for deeper installation depth resp. car driveable with cone and BS60 (isometric to VS60) ** A shaft DN 200 with a height of 620 mm is within the scope of delivery, extensions for that as well as drivable covers have to provided by the customer. DOKK5201E KB SOLIDO engl. Seite 7 von 12
8 3.6 SOLIDO as version with wider shaft elements with spacer ring DN 800, cone and VS SOLIDO 5 E-35-II as lorry drivable version with cone and spacer ring (Drivable >3,5to <12to, more than 12to by request) * Adjustable by shortening the spacer ring ** A shaft DN 200 with a height of 620 mm is within the scope of delivery, extensions for that as well as drivable covers have to provided by the customer. DOKK5201E KB SOLIDO engl. Seite 8 von 12
9 4. Multiple container plants 4.1 SOLIDO standard two-container plants in MONOLITH II Example SOLIDO 16 E-60/60 Measures two container plant SOLIDO (standard version in MONOLITH II) Name Order No. Length Width Height (incl. shaft) Weight SOLIDO 10 E-35/ PE SOLIDO 12 E-45/ PE SOLIDO 16 E PE KBMS x 240 cm 124 cm 220 cm 2 x 200 kg KBMS x 307 cm 122 cm 220 cm 2 x 240 kg KBMS x 340 cm 122 cm 249 cm 2 x 340 kg DOKK5201E KB SOLIDO engl. Seite 9 von 12
10 4.2 SOLIDO multiple container plant in MONOLITH II (without drawing) Measures multiple container plant SOLIDO (standard version in MONOLITH II) Name Order No. Length Width Height (incl. shaft) Weight SOLIDO 18 E-45+45/ PE SOLIDO 24 E-60+60/ PE SOLIDO 32 E-60+60/ PE KBMS x 307 cm 122 cm 220 cm 3 x 240 kg KBMS x 340 cm 122 cm 249 cm 3 x 340 kg KBMS x 340 cm 122 cm 249 cm 4 x 340 kg 4.3 SOLIDO Plus two container plant in MONOLITH I (with big sludge reservoir) Inlet Pretreatment/Buffer Outlet Measures two container plant SOLIDO Plus with big sludge reservoir in MONOLITH I Name Order No. Length L1 + L2 Width Height (incl. shaft) Weight SOLIDOPlus 30/15 KBMS cm +128 cm 120 cm cm 200 kg kg SOLIDOPlus 35/20 KBMS cm +160 cm 120 cm cm 220 kg kg SOLIDOPlus 50/30 KBMS cm +208 cm 120 cm cm 280 kg kg DOKK5201E KB SOLIDO engl. Seite 10 von 12
11 4.4 SOLIDO BlackLine multiple container plant (without drawing) Measures multiple container plant SOLIDO BlackLine Name Order No. Length L1 + L2 Width Height (incl. shaft) Weight BlackLine 20 E-75/ PE BlackLine 26 E-90/ PE BlackLine 28 E-75+75/ PE BlackLine 36 E-90+90/ PE BlackLine 42 E-75+75/ PE BlackLine 50 E-90+90/ PE KBMS x 246 cm 208 cm 290 cm 2 x 280 kg KBMS x 344 cm 206 cm 290 cm 2 x 370 kg KBMS x 246 cm 208 cm 290 cm 3 x 280 kg KBMS x 344 cm 206 cm 290 cm 3 x 370 kg KBMS x 246 cm 208 cm 290 cm 4 x 280 kg KBMS x 344 cm 206 cm 290 cm 4 x 370 kg DOKK5201E KB SOLIDO engl. Seite 11 von 12
12 5. Performance results corresponding to EN REWATEC GmbH May 2013 We reserve the right of technical modifications. No responsibility for printing mistakes will be accepted. The contents of the installation and commissioning are part of the guarantee requirements. DOKK5201E KB SOLIDO engl. Seite 12 von 12
The New Generation in Decentralised Wastewater Treatment. State of the Art SBR-Treatment. Compact and efficient, simple to install
State of the Art SBR-Treatment Compact and efficient, simple to install High and reliable quality Made in Germany Easier is better! The New Generation in Decentralised Wastewater Treatment How it works
More information/ /
This document is brought to you by 01371 850537 / info@ohel.co.uk / www.ohel.co.uk Domestic Wastewater Treatment SOLIDO The Natural Solution The SOLIDO. A simple and professional solution for domestic
More informationin PE container MONOLITH: SOLIDO PT DOKK5105E TD SOLIDO 2016 Qualified advice by telephone: +49 (0) (9:00 to 16:00, CET)
Technical Documentation (Instruction Manual and Operations Logbook) Fully Biological SBR Wastewater Treatment System SOLIDO for Small Wastewater Treatment Plants DOKK5105E 251016 TD SOLIDO 2016 in PE container
More informationDELPHIN cube. Reliable process Strong tanks Clever modules. Compact biological wastewater treatment plants with fixed-bed technology
DELPHIN cube Compact biological wastewater treatment plants with fixed-bed technology DELPHIN Water Systems GmbH & Co. KG The experts for fixed-bed technology Modular system for decentralized wastewater
More informationquickone+ aerated cabinet clearwater sampling backflush HQ membranes installation weight single chamber SBR KIT
quickone+ single chamber SBR KIT aerated cabinet clearwater sampling backflush HQ membranes installation weight one KIT for ALL TANKS with or without baffle wall delivery installation 30 min ready sludge
More informationACO Marine product catalogue ACO Clara Waste water treatment plant Sizes 3-240
ACO Marine product catalogue ACO Clara Waste water treatment plant Sizes 3-240 ACO CLARA ACO Clara Characteristics and application ACO Clara sewage treatment plants are designed for the complete biological
More informationWSB clean: Installation Manual
WSB clean: Installation Manual Models: WSB 400 WSB 1250 WSB 500 WSB 1500 WSB 600 WSB 1600 WSB 750 WSB 1800 WSB 1000 TABLE OF CONTENTS 1 INTRODUCTION...3 2 SAFETY INFORMATION...3 3 WSB CLEAN SYSTEM OPERATION...4
More informationSimply clean water. PUROO. Installation Instructions. Preparation & Installation
Simply clean water. PUROO Installation Instructions Preparation & Installation Contents Page 2: Contents Page 3: Brief description of the plant Page 4: Scope of delivery Page 5: Data sheets Page 16: General
More informationDecember Labko BioKem Wastewater Treatment Plants. Product brochure BATCH REACTORS FOR PROCESSING WASTEWATER OF 6-90 PERSONS
December 2006 Labko BioKem Wastewater Treatment Plants Product brochure BATCH REACTORS FOR PROCESSING WASTEWATER OF 6-90 PERSONS Reliable solutions Wastewater treatment systems Labko BioKem Batch Reactors
More informationCo-treatment of Septage with Municipal Wastewater in Medium Sized Cities in Vietnam
Co-treatment of Septage with Municipal Wastewater in Medium Sized Cities in Vietnam David Robbins Sher Singh PE, Ross Kearton SCE Aménagement & Environnement for Cities Development Initiative for Asia
More informationGL0098P Beta+ Septic Tanks Installation & Operation Guidelines
000535 GL0098P Beta+ Septic Tanks Installation & Operation Guidelines Kingspan Environmental Service Contact Numbers: UK: 0844 846 0500 NI: 028 3025 4077 IRL: 048 3025 4077 Enclosed Documents DS1151P Beta+
More informationStone Food Machinery Ltd 14 North Main Street Wexford IRELAND Tel
Stone Food Machinery Ltd 14 North Main Street Wexford IRELAND E-mail: info@stonefoodmachinery.com WWW.STONEFOODMACHINERY.COM Tel- +353 53 9147800 Copyright 2008 1 Overview of Volute Dewatering Press Flow
More informationPoly-sump PKS-B 800 for submersible sewage pumps With plastic valves and guide rail. Application. Description
PKS-B 800 for submersible sewage pumps With plastic valves and guide rail Application The buoyancy proof sump is supplied as a complete prefabricated pump station for use with pressure drainage systems
More informationAutomatic back-flushing filter AutoFilt RF4
Automatic back-flushing filter AutoFilt RF4 RF4-1 RF4-2 Specifications Nominal size: G1 G 1½ Q max: 220 l/min p max: 16 bar Filtration ratings: 30 1000 µm 1. GENERAL Product description Self-cleaning automatic
More informationSequencing Batch Reactor. Maintenance Manual. Only modules bearing the NSF logo and designated PS1-XX are certified to NSF/ANSI Standards 40 and 245
Sequencing Batch Reactor Maintenance Manual Only modules bearing the NSF logo and designated PS1-XX are certified to NSF/ANSI Standards 40 and 245 2017 Anua 12-2017 Table of Contents Maintenance Manual
More informationABS lifting station Synconta
15975187GB (03/2006) 106800 GB Installation and Operating Instructions www.absgroup.com Installation and Operating Instructions 601 801 901 901L 902 902L Contents 1 General... 3 1.1 Application areas...
More informationThe Pump Matic Range
The Below Ground packaged pumping Stations Ideal for - Sewage, Wastewater, Stormwater Pump Technology Ltd, manufactures its own pumping station tanks. We have complete control over the construction, quality
More informationSequencing Batch Reactor. Reference Manual. Only modules bearing the NSF logo and designated PS1-XX are certified to NSF/ANSI Standards 40 and 245
Sequencing Batch Reactor Reference Manual Only modules bearing the NSF logo and designated PS1-XX are certified to NSF/ANSI Standards 40 and 245 2017 Anua 12-2017 Table of Contents 1.0 What s in the Box?
More informationSeptic Tank. Installation Guidelines
Septic Tank Installation Guidelines INSTALLATION GUIDELINES FOR WPL SEPTIC TANKS These guidelines represent Best Practice for the installation of spherical SEPTIC tanks. It must be noted, however that
More informationSEPTIC TANKS. Round septic tanks. Standard version ECO version. Rectangular septic tanks. ECO version
SEPTIC TANKS Round septic tanks Standard version ECO version Rectangular septic tanks Standard version ECO version Reinforced vertical septic tanks Reinforced horizontal septic tanks Grease traps for private
More informationA E R Z E N S C R E W C O M P R E S S O R S
A E R Z E N S C R E W C O M P R E S S O R S AERZEN - DELTA TWIN - Two Stage Screw Compressors Oil free compressed air technology A E R Z E N E R M A S C H I N E N F A B R I K G M B H V1-016 01 EN 2000
More informationSeparators. The new rotomoulded tank system ACO Grease, starch and light liquid separators for below ground installation
he new rotomoulded tank system ACO Grease, starch and light liquid separators for below ground installation ACO Grease, starch and light liquid separators for below ground installation Commercial operations
More informationInstruction Manual. Sewage lifting station compli 300
Instruction Manual Sewage lifting station compli 300 Safety instructions Areas of application Electrical connection Installation Servicing Technical data Appendix JUNG PUMPEN GmbH Industriestr. 4-6 33803
More informationINSTALLATION AND OPERATING INSTRUCTIONS FOR CONCRETE VAULT TYPE UNITS
INSTALLATION AND OPERATING INSTRUCTIONS FOR CONCRETE VAULT TYPE UNITS CONTENTS Introduction Safety Operating Principle System Installation Initial Startup System Operations Troubleshooting Maintenance
More informationAutomatic Back-Flushing Filter for Process Technology AutoFilt RF3.
Automatic Back-Flushing Filter for Process Technology AutoFilt RF3. AutoFilt RF3: So automatic, The Challenge Particle contamination in process water and other operating fluids accelerates the rate of
More informationROTAMAT Sludge Acceptance Plant Ro 3
ROTAMAT Sludge Acceptance Plant Ro 3 with integrated screenings washing and pressing The Quality Company Worldwide HUBER provides complete systems and processes for septic sludge treatment. Our equipment,
More informationJUNG PUMPEN COMPLI 1500 / 2500 SEWAGE LIFTING STATIONS
APPLICATION The compli 1500 and 2500 tank systems have been designed for large industrial and communal wastewater volumes as well as for the connection of streets or other community effluent systems. In
More informationGAMMA Septic Tanks Installation & Operation Guidelines
017906 GAMMA Septic Tanks Installation & Operation Guidelines Kingspan Environmental Service Contact Numbers: UK: 0844 846 0500 NI: +44 283025 4077 IRL: +44 283025 4077 NOR : +47 22 021 920 Enclosed Documents
More informationHYDROCARBON SEPARATORS
HYDROCARBON SEPARATORS Hydrocarbon separators class I in PE Standard version (to install in consolidated sand) Reinforced version (to install in sand) Without and with mud trap Hydrocarbon separators class
More information77014 / Automatic Users Manual. Carefully read this entire Instruction Manual before using this product
77014 / 65041 Submersible Water Pumps Automatic Users Manual Carefully read this entire Instruction Manual before using this product Please read these operating instructions carefully and ensure they are
More informationLevel Measuring Sensor for Diesel Fuel Tanks
Installation and Operating Manual Level Measuring Sensor for Diesel Fuel Tanks Executions with switchable output voltage signal: 0-2.3 V and industrial standard signal 0-10 V: Tank Sensor Diesel 010-250
More informationJUNG PUMPEN COMPLI 100 MC SEWAGE LIFTING STATIONS
APPLICATION The sewage lifting stations compli 100, compli 500 and compli 1000 with MultiCut cutting system are uses especially for disposal in special objects, such as weekend cottages, houseboats, toilets
More informationIntroduction. Introduction. Introduction. Sludge handling in small and mid-size treatment plants. - Introduction
Sludge handling in small and mid-size treatment plants Dr.-Ing. Jörn Einfeldt (Privatinstitut für Klärtechnik GmbH, D-23611 Bad Schwartau, Germany) - - Case Examples: Small Treatment Plants (i.e. WWTPs
More informationNational/scandinavian requirements for septic tanks
National/scandinavian requirements for septic tanks Rørcentret Inge Faldager Teknologisk Institut Fred Nyberg, Nafal AB CEN TC 165 / WG 41 Small wastewater treatment systems < 50 PT Overview A 1 or 4 2
More informationMD x230V. Grundfos Pump GRUNDFOS DATA BOOKLET
GRUNDFOS DATA BOOKLET MD.24.3.2 3x23V Grundfos Pump 979191 Thank you for your interest in our products Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/muldoub/979191/md-24-3-2.html
More informationFiltration Solutions for Bottle Washing Machines
Filtration Solutions for Bottle Washing Machines BOLLFILTER Automatic for your washing process. Maximum plant protection. Minimum operating costs. Filtration specialist for the beverage industry As a specialist
More informationTURBO BLOWER PACKAGES
TURBO BLOWER PACKAGES Volume flow from 500 cfm to 20000 cfm Direct Driven, High Speed Turbo Blowers aerzenusa.com Aerzen Turbo Blowers Aerzen Turbo Blowers are single-stage high-speed radial turbo blowers
More informationCATALOGUE SEWAGE MANHOLES
CATALOGUE SC SEWAGE MANHOLES Table of contents TABLE OF CONTENTS Introduction 4 Inspection chamber, type 315 7 Inspection chamber, type 400 10 Inspection chamber, type 425 14 Assembly instruction 19 Catch
More informationProduct Catalog TTB Tauchertechnik Brandenburg GmbH
Product Catalog TTB Tauchertechnik Brandenburg GmbH Production and distribution of state-of-the-art hydrostatic test stations and systems for steel and composite compressed-air cylinders Table of contents
More informationLifting Station Type ABS Synconta 900B
310.190.014.010 EN (01/2017) 1068-00 EN Installation and Operating Instructions www.sulzer.com 2 Installation and Operating Instructions (Original Instructions) 901B 902B Symbols and notices used in this
More informationTREATMENTOF PETROCHEMICAL WASTEWATERS
Report No. 80 TREATMENTOF PETROCHEMICAL WASTEWATERS by EARL D. OLIVER September 1972 A private report by the PROCESS ECONOMICS PROGRAM STANFORD RESEARCH INSTITUTE I I MENLO PARK, CALIFORNIA CONTENTS 1
More informationSeparators. The new rotomoulded tank system ACO Grease, starch and light liquid separators for below ground installation
he new rotomoulded tank system ACO Grease, starch and light liquid separators for below ground installation ACO Grease, starch and light liquid separators for below ground installation Commercial operations
More informationJUNG PUMPEN compli 100 MC Sewage lifting stations
Application The sewage lifting stations compli 100, compli 500 and compli 1000 with MultiCut cutting system are uses especially for disposal in special objects, such as weekend cottages, houseboats, toilets
More informationGas Insulated Metal-clad Switchgear, HMGS!
Medium Voltage HMGS-G10 HYUNDAI Medium Voltage Gas Insulated Metal-clad Switchgear, HMGS! SF6 Gas Insulated Metal-clad Switchgear is an integrated assembly of vacuum circuit breaker, 3-position switch,
More informationAutomatic Back-Flushing Filter AutoFilt RF9.
Automatic Back-Flushing Filter AutoFilt RF9. AutoFilt RF9 Clearing the Way. The Challenge: In response to the Tier III standard which will come into effect in 2016, the International Maritime Organization
More informationUnderground Drainage Manhole & Inspection Chambers Prefabricated Polyethylene (PE)
Underground Drainage Manhole & Inspection Chambers Prefabricated Polyethylene (PE) July 2013 1 Material July 2013 7 Production Material Polyethylene (PE) Virgin material 100 % Recycling-contents Foam-contents
More informationGridBee AP Series - Air-Powered Mixers
GridBee AP Series - Air-Powered Mixers Wastewater Lakes / Raw Water Reservoirs Stormwater Industrial AP500 version is designed for wet wells, lift stations and industrial tanks / basins. AP2000, AP4000
More informationKESSEL-Grease Separator Under sink
INSTRUCTIONS FOR INSTALLATION, OPERATION AND MAINTENANCE KESSEL-Grease Separator Under sink Order Number 93025.00/US Product advantages Compact structure fully adjustable inlet 290 to 420 260 350 release
More informationGB-35. Submittal Specifications Installation Application Specific Details. PART #: XX DWG BY: C. O'Boyle DATE: 10/08/2015 REV: 0 / /201_ ECO:
GREASE INTERCEPTOR TECHNICAL DATA Submittal Specifications Installation Application Specific Details 33" (83.8 cm) 10" (25.4 cm) (63.5 cm) 15" (38.1 cm) (63.5 cm) SUBMITTAL STANDARD: 3" plain end inlet/outlet
More informationProfluid and Gap-type tube filters. Automatic filters
and Gap-type tube filters Automatic filters and Gap-type tube filters the efficient answer for multi-purpose applications Identical technology two different cleaning principles Automatic filters such as
More informationAUTOMATIC AIR VALVES For potable water
AUTOMATIC AIR VALVES For potable water Page N Air release valve Page N Air release valve avent Page N Air release valve DN 0 / DN 0, DN 150 / DN 00 Page N /1 Page N5 Combined air release valve Page N 5/1
More informationInstallation and Operation Instruction Manual INSMAN-201. Industrial Multi Media Single Tank
Installation and Operation Instruction Manual INSMAN-201 Industrial Multi Media Single Tank Phone: 951.656.6716 Toll-Free: 800.854.4788 www.yardneyfilters.com 1 Yardney Water Management Systems, Inc. 6666
More informationACO product catalogue ACO GRP Light Oil Separators ACO Oleopator Bypass G
ACO product catalogue ACO GRP Light Oil Separators ACO Oleopator Bypass G ACO. The future of drainage Glass Fibre Light Oil Separators Oleopator Bypass G collect: Collect and remove clean: Pre-clean and
More informationTECHNICAL DESCRIPTION
TECHNICAL DESCRIPTION Of PROJECT : Yacht Hotel Ship SHIPYARD : Boustead Naval Shipyard SHIPOWNER : Sunborn Internation PUMP CAPACITY : 250m3/hr 1 set Skid Type DATE : Apr. 20th, 2011 PANASIA CO., LTD.
More informationINDUSTRIES INDUVENT. With the patented Teddington EVOLVENT Nozzle Technology.
INDUSTRIES INDUVENT With the patented Teddington EVOLVENT Nozzle Technology. Teddington INDUVENT The standard air curtain system for the industry... Compact, flexible, high performance. 2 Highly frequented
More informationSeparators. industrieblick Fotolia.com. For indoor or below ground installation ACO Light Oil Separators Coalisator-P
Separators industrieblick Fotolia.com For indoor or below ground installation ACO Light Oil Separators Coalisator-P Light Oil Separators Application If mineral oils or light oils, especially those that
More informationInstallation, Operation & Maintenance Manual. TotlSep (TS) Series. FRP Oil/Water Separator
THE ART & SCIENCE OF WASTEWATER TREATMENT Installation, Operation & Maintenance Manual TotlSep (TS) Series FRP Oil/Water Separator Revised 09/2015 TABLE OF CONTENTS 1.0 PREFACE... 3 1.1 BACK CHARGE POLICY...
More information1. Tank cleaning system
TENDER TEXT / SPECIFICATION 1. Tank cleaning system Tank type: Bumped-type stormwater overflow tank/stormwater retention tank/storage chamber* In Multijet design, comprising a Multijet submersible motor
More informationoriginal operating manual Operating manual Manual flow meter FMOGne Translation of the Item-No.: ,
Operating manual Manual flow meter FMOGne Item-No.: 027170211, 027170221 Translation of the original operating manual Important! Copyright The operating manual is always to be read before commissioning
More informationUPP Polyethylene Dispenser Sump
UPP Polyethylene Dispenser Sump For Standard and Ribbed sump models DS2111, 4111, 3017, 4417, 3617 and 3915 Installation Guide Franklin Fueling Systems 3760 Marsh Rd. Madison, WI 53718 USA Tel: +1 608
More informationAPPENDIX B FUNCTIONAL DESIGN SPECIFICATIONS (Sequence of Operation)
APPENDIX B FUNCTIONAL DESIGN SPECIFICATIONS (Sequence of Operation) B.1 WATER SUPPLY FACILITIES 1. General A. The tag number of the equipment comprise three designations (W10 CM 01), where the three designations
More informationAqualift F XL Lifting Stations
Aqualift F XL Lifting Stations For industrial / high volume wastewater disposal Leading in Drainage Product Information Applications For use with wastewater from commercial, public and private sources
More informationThe JET Filter. Scope of Delivery. patented. The New Definition of Purity for Your Medium. Our Filter Systems Protect
GB JET Filter The New Definition of Purity for Your Medium Our Filter Systems Protect The JET Filter Cooling Water River Water Plate Heat Exchangers Spray Nozzles Sea Water Sinter and Scale Separation
More informationServo solenoid valves with on-board electronics (OBE)
Servo solenoid valves with on-board electronics (OBE) RE 29077/01.05 1/16 Replaces: 01.03 Type 4WRVE10...25 Size 10, 16, 25 Unit series 2X Maximum working pressure P, A, B 350 bar, T, X, Y 250 bar Nominal
More informationMD x400V. Grundfos pump GRUNDFOS DATA BOOKLET
GRUNDFOS DATA BOOKLET MD.15.3.4 3x4V Grundfos pump 979187 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/muldoub/979187/md-15-3-4.html
More informationKAESER FILTER. KF F350 to F3360 Series Reliable purity for high flow rates Flow rate 35.4 to m³/min, Pressure 2 to 16 bar COMPRESSORS
COMPRESSORS KAESER FILTER KF F350 to F3360 Series Reliable purity for high flow rates Flow rate 35.4 to 336.3 m³/min, Pressure 2 to 16 bar www.kaeser.com KF F350 to F3360 series Clean compressed air at
More informationCTB3365x Introduction to Water Treatment
CTB3365x Introduction to Water Treatment W4c Dimensioning of secondary clarifier Merle de Kreuk Today we will tackle the third unit of the biological part of the sewage treatment plant. You learned the
More informationFIX collars for pipe-connection
FIX collars for pipe-connection DN item-no. cast-iron/cast-iron without supporting ring cast-iron/pe with supporting ring cast-iron/pe without supporting ring cast-iron/steel without supporting ring Steel/PE
More informationTechnical Specification Number S121 for Insulating Oil Purification Plant, Type E rev Q CONTENTS
CONTENTS 1. GENERAL 2. SCOPE OF SUPPLY 3. DUTY AND PERFORMANCE 4. PROCESS DESCRIPTION 5. MAIN COMPONENTS 6. INSTRUMENTATION 7. ALARMS AND INTERLOCKS 8. OPTIONAL EQUIPMENT AND ACCESSORIES 9. COMMISSIONING
More informationPOSITIVE DISPLACEMENT BLOWERS & VACUUM PUMPS. Water & Wastewater Treatment Solutions
POSITIVE DISPLACEMENT BLOWERS & VACUUM PUMPS Water & Wastewater Treatment Solutions Water & Wastewater Treatment Solutions Gardner Denver understands the complex needs and challenges of the water and wastewater
More informationJUNG PUMPEN BAUFIX 200. Instruction Manual
JUNG PUMPEN BAUFIX 200 EN Instruction Manual B 48216-10-1705 www.jung-pumpen.de Baufix 200-32 2 3 Qualification and training of personnel All personnel involved with the operation, servicing, inspection
More informationStimulation of aerobic and anaerobic biological processes by ultrasound
Stimulation of aerobic and anaerobic biological processes by ultrasound Uwe Neis Prof. Dr.-Ing. (em.) Technical University Hamburg-Harburg Institute of Wastewater Management and Water Protection Izabela
More informationWater Solutions. API Oil/Water Separators - A Total Approach. siemens.com/energy/water-solutions
Water Solutions API Oil/Water Separators - A Total Approach siemens.com/energy/water-solutions Backed by over 70 years of experience providing new, innovative and cost-effective wastewater treatment solutions,
More informationBlast Valves for HVAC Ducting
Blast Valves for HVAC Ducting Introduction European EMC Products Ltd was established in July 1996 to supply high quality products and services to the Electro- Magnetic Compatibility (EMC) market. Quality
More informationThe new rotomoulded tank system ACO Grease and light liquid separators for below ground installation
he new rotomoulded tank system ACO Grease and light liquid separators for below ground installation ACO Light liquid separator Oleopator P Class I Light liquid separator of polyethylene for below ground
More informationSUBMERSIBLE DIRTY WATER PUMP
FOR USE WITH A 110V SUPPLY ONLY SUBMERSIBLE DIRTY WATER PUMP MODEL NO: DWP210A PART NO: 7230102 OPERATION & MAINTENANCE INSTRUCTIONS LS0115 INTRODUCTION Thank you for purchasing this CLARKE Submersible
More informationVACOMASS. Technical information VACOMASS square diaphragm control valve
VACOMASS Technical information VACOMASS square diaphragm control valve Diaphragm control valve with a square shaped control aperture and falling flow axis VACOMASS SQUARE DIAPHRAGM CONTROL VALVE The VACOMASS
More informationACO Light liquid separator Oleopator P Class I. Oleopator P Order data. Light liquid separators
Light liquid separators ACO Light liquid separator Oleopator P Class I Light liquid separator of polyethylene for below ground installation according to EN 858 certificate 7310434-01 () 7310434-02 () 7310434-03
More informationPump Station. Ama-Porter CK Pump Station. Type Series Booklet
Pump Station Ama-Porter CK Pump Station Type Series Booklet Legal information/copyright Type Series Booklet Ama-Porter CK Pump Station All rights reserved. The contents provided herein must neither be
More informationExtended Warranty for total peace of mind
Extended Warranty for total peace of mind Bond Service Plan for your sewage treatment plant Kingspan Environmental Services has introduced a new BOND SERVICE PLAN option that will give you: Extended Warranty
More informationTHE RS SCREW COMPRESSOR RANGE
Manufacturer of Compressors Hersteller von Kompressoren Fabricant de Compresseurs Made in Germany Your reliable partner for the supply of environmentally friendly compressed air, with minimal energy consumption
More informationABB drives for water and wastewater ACQ to 500 kw
Low voltage AC drives ABB drives for water and wastewater ACQ810 0.37 to 500 kw The intelligent drive choice for water and wastewater applications The ACQ810 drive for water and wastewater applications
More informationSignet ph/orp Electrodes
Signet 2724-2726 ph/orp Electrodes Compatible with ALL Signet ph/orp Instruments Features Patented reference design for exceptional performance * Mounts in Signet standard fittings from DN15 to DN100 (½
More informationoriginal operating manual Operating manual Translation of the Item-No.: ,
Translation of the original operating manual Operating manual Item-No.: 015 431 551, 015 431 581 Important! Copyright The operating manual is always to be read before commissioning the equipment. No warranty
More informationHigh Voltage and Extra High Voltage Cables
High Voltage and Extra High Voltage Cables GUIDE TO THE SELECTION OF EHV AND HV CABLES EHV and HV cables are specially designed on the basis of the project data. To determine appropriate design of a high
More informationTable of Contents 2.0 EIGERFLEX CPE. 2.0 Table of Contents
Table of Contents 2.0 2.0 Table of Contents 2.1 System description 2.100 System description (general) 2.105 System description (data) 2.115 DN 20 - DN 40 with frost protection strip, Ø carrier pipe 25-50
More informationTrelleborg Specialty Mining Hoses
Trelleborg Specialty Mining Hoses Trelleborg Wear Resistant Specialty Mining Hose Specialty flexible mining hoses are critical components for effective and efficient material handling in heavy media and
More informationContinuous level measuring system NB 3000 Selection list
Table of contents Page Overview 2 ------------------------------------------------------------------------------------------------------------------- Specifications 3 -------------------------------------------------------------------------------------------------------------------
More informationLOWeFLOW -UV Treatment System O& M and Troubleshooting Manual January 2017
LOWeFLOW -UV Treatment System O& M and Troubleshooting Manual January 2017 US Patent 8,889,007 Manufactured by: Lowridge Onsite Technologies PO Box 1179 Lake Stevens, WA 98258 O: 877 476-8823, C: 425 750-4922
More informationSimply a question of better measurement
Simply a question of better measurement Flow sensors for air and gases SCHMIDT Flow Sensors Solutions for measuring technology in practice SCHMIDT Technology is a specialist in the development and production
More informationOperating Instructions
Operating Instructions Ex UPS Combination of > 8265/5 GUBox control panel > 8316 battery box Contents 1 Contents 1 Contents 2 2 General Information 2 3 Safety Instructions 2 4 Conformity to standards 3
More informationSludge Thickening. Wastewater Treatment Review. Gravity Thickening
Wastewater Treatment Review 10 Sludge Thickening nw ate rc oll e ge 20 Gravity Thickening ca Principle of Operation 1. Uses gravitational forces to separate water from sludge 2. Solids settle to bottom
More informationInstallation and maintenance instructions for the GRAF Universal External and internal Filter 3
Installation and maintenance instructions for the GRAF Universal External and internal Filter 3 Universal Filter 3 for external green areas Order- No.: 340020 Universal Filter 3 external for areas traversed
More informationBackflushing Filter AutoFilt RF3
Backflushing Filter AutoFilt C 2,5 4 6 8 1. TECHNICAL SPECIFICATIONS 1.1 GENERAL The automatic back-flushing filter AutoFilt is a self-cleaning system for extracting particles from lowviscosity fluids.
More informationMANN+HUMMEL ENTARON The new two-stage filter flexible and designed for compact installation spaces
Entaron en:entaron en 30.06.2011 11:38 Uhr Seite 1 MANN+HUMMEL ENTARON The new two-stage filter flexible and designed for compact installation spaces ENTARON: developed for the highest requirements MANN+HUMMEL
More informationAMERICAN RECIRCULATING SAND FILTER SYSTEMS
American Manufacturing Company, Inc. P.O. Box 549, Manassas, VA 20108 1-800-345-3132 AMERICAN RECIRCULATING SAND FILTER SYSTEMS ENGINEERING DESIGN GUIDELINES FOR COMMUNITY AND COMMERCIAL SIZED TREATMENT
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS EARTHSAFE D10 WASTEWATER TREATMENT SYSTEM A. PREPARING THE SITE INSTALLATION SUGGESTIONS See if you can site the tanks away from commonly used vehicular access, and also away
More informationSANITARY COMPRESSED AIR COMPRESSORS. with membrane dryer with thermal protection with hour meter
SANITARY COMPRESSED AIR COMPRESSORS with membrane dryer with thermal protection with hour meter Reliable solutions for the dental office Highest medical standard Compressed air used in dental practices
More informationSignet ph/orp Electrodes
Signet 2724-2726 ph/orp Electrodes Compatible with ALL Signet ph/orp Instruments Features Flat Glass Protected Bulb Patented reference design for exceptional performance * Mounts in Signet standard fittings
More informationSaniTEE Wastewater Screens Installation & Service Manual FOR USE WITH SNT416, SNT418, SNT818, SNT 838, SNT1618, and SNT1638
SaniTEE Wastewater Screens Installation & Service Manual FOR USE WITH SNT416, SNT418, SNT818, SNT 838, SNT1618, and SNT1638 SaniTEE Manual Bio-Microbics, Inc. Revised December 2009. SaniTEE is a registered
More information