1 THE WALL-MOUNT QUIET-CLIMATE HEAT PUMPS Models: SH21, SH311, SH31, SH431, SH41, SH High Efficiency Heating Capacities: 21, to 55, Ultra Low Sound Level Cooling Capacities: 23, to 55, Refrigerant 22 The Bard Wall-Mount Heat Pump is a self-contained energy efficient heating and cooling system, which is designed to offer maximum indoor comfort at a minimal cost without using valuable indoor floor space or outside ground space. This unit is the ideal product for versatile applications such as: new construction, modular offices, school modernization, telecommunication structures, portable structures or correctional facilities. Factory or field installed accessories are available to meet specific job requirements. Engineered Features Aluminum Finned Copper Coils: Grooved tubing and enhanced louvered fin for maximum heat transfer and energy efficiency. Twin Blowers: Move air quietly. All models feature multispeed blower motors providing airflow adjustment for low static or free blow (non-ducted) operation at a very low sound level or ducted installations (low pressure duct systems not to exceed.2" W.C.). Units are shipped connected for ducted installations. Motor overload protection is standard on all models. Heat Pump Compressor: compressor designed for increased efficiency, quieter operation and improved reliability for longer life. Eliminates need for a suction accumulator. Phase Rotation Monitor: Standard on all 3 phase scroll compressors. Protects against reverse rotation if power supply is not properly connected. Condenser Fan and Motor Shroud Assembly: Slide out for easy access. One Inch, Disposable Air Filters: Are standard equipment. Optional 1" washable filters available and filter racks permit the addition of 2" pleated filter. Factory or field installed. Solid State Electronic Heat Pump Control: Provides efficient 3, or -minute defrost cycle. A thermistor sensor, speed up terminal for service and minute defrost override are standard on the electronic heat pump control. High Pressure Switch: Is built-in with a lockout circuit that resets from the room thermostat. Five Minute Compressor Time Delay: Short cycle protection is standard. Built into the heat pump control. Emergency Heat Circuit: Permits continuous operation of the system. Galvanized 2 Gauge Zinc Coated Steel Cabinet: Cleaned, rinsed, sealed and dried before the polyurethane primer is applied. The cabinet is handsomely finished with a baked on, beige textured enamel, which allows it to withstand hours of salt spray tests per ASTM B Electrical Components: Are easily accessible for routine inspection and maintenance through a right side, service panel opening. Features a lockable, hinged access cover to the circuit breaker. Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages are factory or field installed. Features easy slide-in field assembly with various outputs. Barometric Fresh Air Damper: Standard on all units. Allows up to 25% outside fresh air. Built-in Circuit Breakers: Standard on all V models. Toggle disconnect on 4V models Slope Top: Standard feature for water run-off. Full Length Mounting Brackets: Built into cabinet for improved appearance and easy installation. NOTE: Bottom mounting bracket included to assist in installation. Top Rain Flashing: Standard feature on all models. Ventilation System Packages All packages are designed to meet your specific ventilation requirements utilizing one of six ventilation options for the product. The ventilation package is mounted within the unit eliminating the need for an exterior mounted hood or damper assembly on the unit. All assemblies can be factory installed, installed in the field at time of installation or as a retrofit system after installation. Standard - Barometric Fresh Air Damper Optional - Motorized Fresh Air Damper Optional - Blank Off Plate Optional - Commercial Room Ventilator With Exhaust CRV - Spring Return CRVP - Power Return Optional - Economizer With Exhaust Optional - Energy Recovery Ventilator With Built-in Exhaust Complies with efficiency requirements of ANSI/ASHRAE/IESNA.1-7. Certified to ANSI/ARI Standard 3-3 for SPVU (Single Package Vertical Units). Commercial Product - Not intended for Residential application. Page 1 of

2 Capacity and Efficiency Ratings MODELS SH21 SH311 SH31 SH431 SH41 SH Cooling 1 24, 2, 35, 42, 4, 55, EER High Temp Heating (47F) 1 21, 25, 33, 37,, 54, Low Temp Heating (17F) 1, 15, 1, 22, 2, 32, Capacity is certified in accordance with ANSI/ARI Standard EER = Energy Efficiency Ratio, = Coefficient of Performance and are certified in accordance with ANSI/ARI Standard 3-3. All ratings based on fresh air intake being % closed (no outside air introduction). Specifications 2 through 3 Ton SH21- B SH21- C SH311- A SH311- B SH311- C SH31- A SH31- B SH31- C / / /1. 7./ /1. 5.3/ / /7 55/ / 77/ / / / / / "-1 2"-1 2"-1 2"-1 2"-1 MODELS SH21- A Electrical Rating -- HZ 1 Operating Voltage Range 3 Compressor -- Circuit A Voltage 3/2 Rated Load Amps./13. 5 Branch Circuit Selection Current 3. 5 Lock Rotor Amps /5 Compressor Type Fan Motor & Condenser Fan Motor -- HP - RPM - SPD /5-5-1 Fan Motor -- Amps. 5 Fan -- DIA - CFM "-1 Motor & Evaporator Blower Motor -- HP - RPM - SPD /5-5-2 Blower Motor -- Amps. 4 CFM Cooling & E.S.P. w/filter (Rated - Wet Coil) -. Filter Sizes (inches) STD x 3 x 1 Shipping Weight -- LBS. 1 1/ / / / / x 3 x 1 1 x 3 x 1 1 x 3 x 1 1 x 3 x 1 1 x 3 x Specifications 3-1/2 through 5 Ton SH431-B SH431-C SH41-A SH41-B SH41-C SH-A SH-B SH-C / / / / / / 44 / 1/1 4 14/14 3/3 1 1/ / / MODELS SH431-A Electrical Rating -- HZ 1 Operating Voltage Range 3 Compressor -- Circuit A Voltage 3/2 Rated Load Amps.2/21. 7 Branch Circuit Selection Current 1. 7 Lock Rotor Amps 4/4 Compressor Type Fan Motor & Condenser Fan Motor -- HP - RPM - SPD / Fan Motor -- Amps. 5 Fan -- DIA - CFM 4"-2 Motor & Evaporator Blower Motor -- HP - RPM - SPD /4--3 Blower Motor -- Amps. CFM Cooling & E.S.P. w/filter (Rated - Wet Coil) -.15 Filter Sizes (inches) STD x 3 x 1 Shipping Weight -- LBS. 1 1/2--3 1/2--3 1/ x 3 x 1 5 Page 2 of

3 Ventilation System Packages Bard Wall-Mounts are designed to provide optional ventilation packages to meet all of your ventilation and indoor air quality requirements. All units are equipped with a barometric fresh air damper as the standard ventilation package. All ventilation packages can be built-in at the factory, or field-installed at a later date. BAROMETRIC FRESH AIR DAMPER - BFAD STANDARD The barometric fresh air damper is a standard feature on all models. It is installed on the inside of the service door and allows outside ventilation air, up to 25% of the total airflow rating of the unit, to be introduced through the air inlet openings and to be mixed with the conditioned air. The damper opens during blower operation and closes when the blower is off. Adjustable blade stops allow different amounts of outside air to be introduced into the building and can be easily locked closed if required. Barometric Fresh Air Damper BLANK OFF PLATE - BOP OPTIONAL A blank off plate is installed on the inside of the service door. It covers the air inlet openings which restricts any outside air from entering into the unit. The blank off plate should be utilized in applications where outside air is not required to be mixed with the conditioned air. MOTORIZED FRESH AIR DAMPER - MFAD OPTIONAL The motorized fresh air damper is internally mounted behind the service door and allows outside ventilation air, up to 25% of the total airflow rating of the unit, to be introduced through the air inlet openings and to be mixed with the conditioned air. The two position damper can be fully open or closed. The damper blade is powered open by a 24VAC motor with spring return on power loss. The damper can be controlled by indoor blower operation or can be field connected to be managed based on building occupancy. Motorized Fresh Air Damper NOTE: The above vent systems are intake only without built-in exhaust capability. Building will likely require separate field installed barometric relief or mechanical exhaust elsewhere within the conditioned space. Balancing dampers in the return air grille may be required to achieve specified amount of outdoor air intake. COMMERCIAL ROOM VENTILATOR - CRV OPTIONAL The built-in commercial room ventilator is internally mounted behind the service door and allows outside ventilation air, up to 5% of the total airflow rating of the unit, to be introduced through the air inlet openings. It includes a built-in exhaust air damper. Commercial Room Ventilator The commercial room ventilator (CRV) is a simple and innovative approach to improving the indoor air quality by providing fresh air intake and exhaust capability through the CRV. The damper can be easily adjusted to control the amount of fresh air supplied into the building. The CRV can be controlled by indoor blower operation or field controlled based on room occupancy. The CRV is power open - spring return on power loss. Complies with ANSI/ ASHRAE Standard.1 Ventilation for Acceptable Indoor Air Quality. Two Models Available: CRVS - spring return on power loss or deactivation CRVP - power return (will not close on power loss) ECONOMIZER - EIFM OPTIONAL The built-in economizer system is internally mounted behind the service door and allows outdoor air to be introduced through the air inlet openings. The amount of outdoor air varies in response to the system controls and settings defined by the end user. It includes a built-in exhaust air damper. The economizer is designed to provide free cooling when outside air conditions are cool and dry enough to satisfy cooling requirements without running the compressor. This in turn provides lower operating costs, while extending the life of the compressor. Economizer Energy Recovery Ventilator Standard Features: One Piece Construction - Easy to install with no mechanical linkage adjustment required. Exhaust Air Damper - Built in with positive closed position. Provides exhaust air capability to prevent pressurization of tight buildings. Actuator Motor - 24 volt, power open, spring return with built in torque limiting switch. Proportioning Type Control - for maximum free cooling economy and comfort. Moisture Eliminator & Prefilter - permanent, washable aluminum construction. Enthalpy Control - adjustable to monitor outdoor temperature and humidity. Minimum Position Potentiometer - adjustable to control minimum damper blade position for ventilation purposes. Mixed Air Sensor - to monitor outside and return air to automatically modulate damper position. WALL-MOUNT ENERGY RECOVERY VENTILATOR - WERV OPTIONAL The wall-mount energy recovery ventilator (WERV) is a highly innovative approach to meeting indoor air quality ventilation requirements as established by ANSI/ASHRAE Standard.1. The WERV allows from to CFM (depending upon model) of fresh air and exhaust through the unit while maintaining superior indoor comfort and humidity levels. In most cases this can be accomplished without increasing equipment sizing or operating costs. Heat transfer efficiency is up to 7% during summer and % during winter conditions. The WERV consists of a unique rotary energy recovery cassette that provides effective sensible and latent heat transfer capabilities during summer and winter conditions. Various control schemes are addressed including limiting ventilation during building occupancy only. The WERV is designed to be internally mounted behind the service door in the WA, WH or WL model wall-mount units. It can be built-in at the factory or field installed as an option. WERV-*3C and WERV-*5C can be independently adjusted for intake and exhaust rates. Page 3 of

4 Commercial Room Ventilator Performance Data : CRVS-3 and CRVP-3 SH21 & SH311 High Speed Total and Ventilation Airflow Total Air.15 ESP Vent Air.15 ESP SH21 & SH311 Low Speed Total and Ventilation Airflow Total Air.15 ESP Vent Air.15 ESP Page 4 of

5 Commercial Room Ventilator Performance Data : CRVS-5 and CRVP-5 SH31 High Speed Total and Ventilation Airflow Total Air.2 ESP Vent Air.2 ESP SH31 Medium Speed Total and Ventilation Airflow Total Air.2 ESP Vent Air.2 ESP SH31 Low Speed Total and Ventilation Airflow 1 1 Total Air.2 ESP Vent Air.2 ESP Page 5 of

6 Commercial Room Ventilator Performance Data : CRVS-5 and CRVP-5 SH431/SH41/SH High Speed Total and Ventilation Airflow Total Air.2 ESP Vent Air.2 ESP SH431/SH41/SH Medium Speed Total and Ventilation Airflow Total Air.2 ESP Vent Air.2 ESP Page of

7 Performance and Application Data - WERV-*5C (SH31, SH431, SH41 & SH) Ambient O.D. SUMMER COOLING PERFORMANCE (INDOOR DESIGN CONDITIONS DB/ WB) V ENTILATION RATE -- CFM V ENTILATION RATE -- 3 CF M VENTILATION RATE -- CF M DB/ W B F V L T V L S V L L H R T H R S H R L V L T V L S V L L H R T H R S H R L V L T V L S V L L H R T H R S HR L WERV-*5C WINTER HEATING PERFORMANCE (INDOOR DESIGN CONDITIONS 7 F DB) Ambient O.D. VENTILATION RATE 4 5 CFM 3 CF M CF M LEGEND: D B/ F W V L W H R W V L W H R W V L WH R VLT = Ventilation Load - Total VLS = Ventilation Load - Sensible VLL = Ventilation Load - Latent HRT = Heat Recovery - Total HRS = Heat Recovery - Sensible HRL = Heat Recovery - Latent WVL = Winter Ventilation Load WHR = Winter Heat Recovery Performance and Application Data - WERV-*3C (SH21 & SH311) NOTE: Sensible performance only is shown for winter application. SUMMER COOLING PERFORMANCE (INDOOR DESIGN CONDITIONS DB/ WB) CFM 25 VENTILATION RATE -- % EFFICIENCY CFM 325 VENTILATION RATE -- 4% EFFICIENCY CFM VENTILATION RATE -- 3% EFFICIENCY Ambient O.D. DB/ W B F V L T V L S V L L H R T H R S H R L V L T V L S V L L H R T H R S H R L V L T V L S V L L H R T H R S HR L WERV-*3C WINTER HEATING PERFORMANCE (INDOOR DESIGN CONDITIONS 7 F DB) 25 CFM 77% EFF. VENTILATION RATE 325 CFM 7% EFF. CFM % EFF. Ambient O.D. LEGEND: VLT = Ventilation Load - Total VLS = Ventilation Load - Sensible VLL = Ventilation Load - Latent HRT = Heat Recovery - Total HRS = Heat Recovery - Sensible HRL = Heat Recovery - Latent WVL = Winter Ventilation Load WHR = Winter Heat Recovery D B/ F W V L W H R W V L W H R W V L WH R application. winter for shown is only performance Sensible NOTE: Page 7 of

8 Clearances Required for Service Access and Adequate Condenser Air Flow MODELS LEFT SIDE RIGHT SIDE A ll Models 2" 2" Minimum Clearances Required to Combustible Materials MODELS 1 SUPPLY AIR DUCT FIRST THREE FEET 1 Refer to the Installation Manual for more detailed information. CABINET A ll Models 1 /4" " Dimensions of Basic Unit for Architectural and Installation Requirements (Nominal) MODEL WIDTH (W) DEPTH HEIGHT (D) (H) SUPPLY RETUR N A B C B E F G I J K L M N O P Q R S T SH21 SH SH31 SH SH41 SH All dimensions are in inches. Dimensional drawings are not to scale inches for model SH on lower two positions only. FRONT VIEW RIGHT SIDE VIEW BACK VIEW Page of

9 Electrical Specifications Single Circuit Dual Circui t Max. Circuit Exterior Fuse Field Power or Wire Size3 Crt. Bkr. 2 No. of Rated Minimum Maximum Field Field Min. Circuit Ground Circuit External Fuse Power Ground Volts, HZ Power Ampacity1 Wire Size3 Ampacity or Circuit Wire Size Wire Size Models and Phase Circuits 1 Breaker Ckt. A Ckt. B Ckt. A Ckt. B Ckt. A Ckt. B Ckt. A Ckt. B SH21-A, AZ A A * SH21-B, BZ B * SH21-C, CZ C * SH311-A, AZ A A * SH311-B, BZ B * 1 3 SH311-C, CZ C * SH31-A, AZ A5 1 or A or A 1 or D A * 1 or SH31-B, BZ B * B * SH31-C, CZ C * C * SH431-A, AZ A5 1 or A or A 1 or D A * 1 or SH431-B, BZ B * B * 1 SH431-C, CZ C C * SH41-A, AZ 1 4 -A5 1 or A or A 1 or D A * 1 or SH41-B, BZ B * B * 1 57 SH41-C, CZ C C * SH-A, AZ 1 4 -A5 1 or A or A * 1 or A2 * 1 or SH-B,BZ B * 1 5 SH-C, CZ C * * These heater KW sizes available in dehumidification models. These electrical ratings also apply to dehumidification models unless listed separately and marked with footnote 5. 1 These Minimum Circuit Ampacity values are to be used for sizing the field power conductors. Refer to the National Electrical Code (latest version), Article 3 for power conductor sizing. Caution: When more than one field power circuit is run through one conduit, the conductors must be derated. Pay special attention to note of Table 3 regarding Ampacity Adjustment Factors when more than three (3) conductors are in a raceway. 2 Maximum size of the time delay fuse or HACR type circuit breaker for protection of field wiring conductors. 3 Based on C copper wire. All wiring must conform to the National Electrical Code and all local codes. 4 Maximum KW that can operate with the heat pump on is KW. 5 Maximum KW that can operate with the heat pump on is 5KW. Maximum KW that can operate with the heat pump on is 4KW. IMPORTANT: While this electrical data is presented as a guide, it is important to electrically connect properly sized fuses and conductor wires in accordance with the National Electrical Code and all local codes. Page of

10 Indoor Blower Performance - CFM at 23 or 4 Volts ESP in Inches Water Column SH21, SH311 SH31 SH431, SH41 SH High Speed Dry/Wet Coil Low Speed Dry/Wet Coil High Speed Med. Speed Dry/Wet Coil Dry/Wet Coil Low Speed Dry/Wet Coil High Speed Med. Speed High Speed Dry/Wet Coil Dry/Wet Coil Dry/Wet Coil Dry/Wet Low Speed Coil. 5/ 5/ 15/ / /1 1/155 14/13 1/155 1/ /5 4/ 14/ /1 / 155/1 13/5 1/1 1/5. 2 / / 135/115 1/25 /5 1/5 5/ 1/135 1/115 Above data is with 1" standard disposable or 1" washable filter For optional 2" pleated filter - reduce ESP by. in. Recommended (factory connected ) motor speed for ducted installation: SH21, SH311, SH31: Medium Speed SH431, SH41, SH: High Speed Reconnect to next lower speed for free blow (non-ducted) installation. Electric Heat Table - Refer to Electrical Specifications for Availability by Unit Model Nominal KW Heater Packages - Field Installed, For Standard (Non-Dehumidification) Models Designed for adding Electric Heat to KW Units Circuit Breaker Standard on All Models Heat Pump Models SH21 SH311 SH31 SH431 SH41 SH A t 24V (1) A t 2V (1) A t 4V (2) At 4V (2) Kw 1-Ph Amps 3-Ph Amps Btuh , , , , , , , (1) These electric heaters are available in V units only. (2) These electric heaters are available in 4V units only. -A Models 21 Heater Model # EHSH31-A4 EHSH31-A EHSH31-A4 EHSH31-A EHWH3-A5 EHWH4-A EHWH4-A EHWH4-A5 EHWH4-A EHWH4-A EHWH1-A5 EHWH1-A EHWH1-A EHWH1A-A2 Kw 1-Ph Amps 3-Ph Amps Btuh , , , , , , ,15 UL Liste d CUL Liste d -B Models -C Models K W Heater Model # K W Heater Model # KW 4 EHSH31-B EHSH31-C 4 EHSH31-B EHSH31-C EHWH3-B EHWH3-B EHWH4-B EHWH4-B Kw 3-Ph Amps Btuh Kw EHWH42-C EHWH5A-C EHWH42-C EHWH5A-C 3-Ph Amps Btuh , , , ,2 EHWH4-B EHWH5A-C Heater Packages - Field Installed, For Dehumidification Models Only Designed for adding Electric Heat to KW Units Circuit Breaker Standard on All Models Heat Pump Models SH21D SH311D -A Models 21 Heater Model # EHSH31-A4 EHSH31-A EHSH31-A4 EHSH31-A SH31D EHWH3DA SH431D, SH41D EHWH4DA SHD EHWH1DA UL Liste d CUL Liste d -B Models -C Models K W Heater Model # K W Heater Model # KW 4 EHSH31-B EHSH31-C 4 EHSH31-B EHSH31-C EHWH3DB EHWH3DB HWH4DB HWH1DB EHWH42-C EHWH3DC HWH4DC HWH1DC 1 E E 1 E E Page of

11 Cooling Application Data - Outdoor Temperature F 1 Model SH21 SH311 SH31 SH431 SH41 SH D.B./W.B. 2 / / 7 5/ 72 / / 7 5/ 72 / / 7 5/ 72 / / 7 5/ 72 / / 7 5/ 72 / / 7 5/ 72 Cooling Capacity F F 5 F F 5 F F 5 F 1 F 115 F 23, 1, 25, 1, 3, 1, 27, 2, 2, 1, 35, 2, 3, 3, 41, 2, 4, 2, 44, 35, 47, 34, 5, 35, 4, 3,, 34,, 35, 5, 4, 5, 3, 71, 3, 23, 1, 25, 1, 2, 1, 2, 2, 2, 1, 33, 1, 3, 2, 3, 2, 4, 2, 42, 34, 4, 33, 53, 34, 4, 35, 51, 34, 5, 34, 54, 3, 5, 3,, 3, 1 Below F, unit requires a factory or field installed low ambient control. 2 Return air temperature F. 22, 1, 24, 1, 2, 1, 25, 1, 2, 1, 32, 1, 34, 2, 3, 2, 43, 2, 4, 33, 44, 32, 51, 32, 44, 34, 4, 33, 57, 33,, 3, 57, 3,, 3, 21, 17, 24, 17, 27, 17, 24, 1, 27, 1, 31, 1, 32, 27, 3, 27, 41, 27, 3, 31, 43, 31, 4, 31, 42, 33, 4, 33, 54, 32, 5, 37, 5, 37, 3, 37, 2, 17, 24, 17, 2, 17, 23, 1, 2, 1, 2, 1, 3, 2, 35, 27, 3, 2, 3, 3, 42, 31, 4, 3, 4, 32, 4, 32, 51, 31, 4, 3, 55, 37, 1, 3, 2, 1, 23, 17, 25, 1, 22, 17, 25, 1, 2, 17, 2, 2, 34, 2, 37, 25, 34, 3, 4, 3, 44, 2, 3, 31, 44, 31, 4, 3,, 35, 53, 3, 5, 35, Capacity Airflow Total 1, 1, 23, 1, 24, 1, 21, 17, 24, 17, 2, 1, 2, 25, 33, 2, 3, 24, 32, 2, 3, 2, 41, 2, 3, 3, 42, 31, 4, 2, 43, 34, 51, 35, 55, 33, 1, 1, 22, 1, 23, 15, 2, 1, 24, 17, 25, 1, 27, 24, 32, 25, 34, 24, 3, 2, 3, 2, 3, 27, 34, 2, 4, 3, 43, 2, 41, 33, 4, 34,, 32, Factors ate , 15, 21, 1, 22, 15, 1, 1, 23, 1, 24, 15, 2, 24, 31, 25, 33, 23, 2, 27, 34, 2, 3, 2, 31, 2, 3, 2, 4, 27, 3, 32, 4, 33, 4, 3, Multiplier % of Rated - R d Sensible Heating Application Rating & Outdoor Temperature F* Model o F 5 o F o F 15 o F 2 o F 25 o F 3 o F 35 o F 4 o F o F 5 o F 55 o F o F 7,,, 11, 13, 14, 15, 15, 1, 2, 21, 23, 24, SH21 WATTS , 11,, 14, 15, 15, 1, 1, 2, 23, 2, 27, 2, SH311 WATTS ,, 15, 17, 1, 2, 22, 23, 27, 31, 34, 3, 3, SH31 WATTS , 15, 1, 21, 23, 2, 2, 31, 33, 3, 3, 41, 44, SH431 WATTS , 21, 24, 2, 2, 32, 34, 3, 41, 43, 4, 4,, SH41 WATTS , 23, 2, 3, 32, 33, 34, 35, 43, 5, 5, 5, 3, SH WATTS * 7 F DB indoor return air at rated CFM includes defrost operation below. Page 11 of

12 Heat Pump Wall-Mount Model Nomenclature SH 3 1 A 5 X X X X X B MODEL NUMBER CAPACITY 2-2 Ton 31-2½ Ton 3-3 Ton 43-3½ Ton 4-4 Ton 1-5 Ton REVISION SPECIALTY PRODUCTS 4 (Non-Standard) Ventilation Options 1 These vents are without exhaust capability and may require separate field installed barometric relief elsewhere within the conditioned space. 2 Intake and exhaust can be independently adjusted. Color option must be specified to match unit (X = Beige, 4 = Buckeye Gray) Factory Installed Code Number VOLTS & PHASE A - //1 B - //3 C - 4//3 Field Installed Part Number B CMH-3 E CMH-7 Low Pressure Control 1 Low Ambient Control and Relay 2 O CMH- Field Installed Only Field Installed Only 5 Field Installed Only All Models Except SH-A Field Installed Only SH-A Only KW1 Z - KW2 4-4KW 5-5KW - KW - KW - KW -KW 2-2KW VENTILATION OPTIONS (See Table) FILTER OPTIONS X - 1-Inch Fiberglass (Standard) W - 1-Inch Washable P - 2-Inch Pleated Description CMH-14A CMC-1 3 COLOR OPTIONS X - Beige 1 - White 2 - Mesa Tan 4 - Buckeye Gray 5 - Desert Brown - Dark Bronze Start Kit 3 Start Kit 4 SK111 4 SK113 4 OUTLET OPTIONS X - Front (Standard) 1 Not all KW available on all models. See pages & for details. 2 Z is KW and circuit breaker (V) or toggle disconnect (4V). Use for KW and no circuit breaker or disconnect. 3 Includes reheat coil on dehumidification models, if applicable. 4 Insert D for dehumidification with hot gas reheat. Reference Form F171 for complete details. Outdoor Thermostat 5 CONTROL MODULES (See Chart Below) COIL OPTIONS X -Standard 1 - Phenolic Coated Evaporator3 2 - Phenolic Coated Condenser 3 - Phenolic Coated Evaporator and Condenser3 MODELS SH21, SH311 SH31, SH431, SH41, SH DESCRIPTION Factory Installed Field Installed Factory Installed Field Installed Code No. Part No. Code No. Part No. Barometric Fresh Air Damper - No Exhaust 1 - Standard X BFAD-3 X BFAD-5 Blank-Off Plate B BOP-3 B BOP-5 Motorized Fresh Air Damper - No Exhaust 1 M MFAD-3 M MFAD-5 Commercial Ventilator - Spring Return w/exhaust V CRVS-3 V CRVS-5 Commercial Ventilator - Power Return w/exhaust P CRVP-3 P CRVP-w/Exhaust Economizer (Internal) - Fully Modulating E EIFM-3 C E EIFM-5 C Energy Recovery Ventilator w/built-in Exhaust 23V R WERV-A3C - 2 R WERV-A5C - 2 Energy Recovery Ventilator w/built-in Exhaust 4V R WERV-C3C - 2 R WERV-C5C - 2 Heat Pump Control Modules 1 The low pressure control is auto reset. It includes a lockout feature and is resettable from the wall thermostat. All low pressure controls use a timed bypass circuit to prevent nuisance tripping during low temperature start-up. 2 The low ambient control includes an 21- (fan relay) and permits cooling operation down to F. 3 PTCR start kit can be used with all -A single phase models. Increases starting torque 2-3x. Not used for -B or -C three phase models. Do not use if SK111 or SK113 is used. 4 Start capacitor and potential relay start kit can be used with all -A single phase models. Increases starting torque x. Not used for -B or -C three phase models. Do not use if CMC-15 is used. 5 The outdoor thermostat is adjustable from F to 5 F. It is suitable for use as a compressor cut-off thermostat. NOTE: Standard heat pump control board has a 5-minute compressor anti-short cycle timer. Page of Bard Manufacturing Company, Inc. Bryan, Ohio Due to our continuous product improvement policy, all specifications subject to change without notice. Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. Form No. S335 February,

THE WALL-MOUNT AIR CONDITIONERS - WA (60HZ)

THE WALL-MOUNT AIR CONDITIONERS - WA (60HZ) THE WLL-MOUNT IR CONDITIONERS - W (HZ) W-SERIES Refrigerant 22 Hz. to Ton (, to 7, Btuh) Right Side Control Panel The Bard Wall-Mount ir Conditioner is a self contained energy efficient system, which is

More information

THE WALL-MOUNT AIR CONDITIONERS - WA (60HZ)

THE WALL-MOUNT AIR CONDITIONERS - WA (60HZ) THE WLL-MOUNT IR CONDITIONERS - W (HZ) W-SERIES Hz. to Ton (,3 to 7, Btuh) Right Side Control Panel Refrigerant The Bard Wall-Mount ir Conditioner is a self contained energy efficient system, which is

More information

THE WALL-MOUNT STEP CAPACITY HEAT PUMPS Integrated Part Load Value (IPLV) Efficiency Up To 15.0 BTU/WATT

THE WALL-MOUNT STEP CAPACITY HEAT PUMPS Integrated Part Load Value (IPLV) Efficiency Up To 15.0 BTU/WATT THE WALL-MOUNT STEP CAPACITY HEAT PUMPS Integrated Part Load Value (IPLV) Efficiency Up To 5.0 BTU/WATT Green Refrigerant R-4A Models: C24H to C0H Up to.0 EER Cooling Capacities: 22,200 to 55,0 BTUH Heating

More information

GREEN REFRIGERANT R-410A

GREEN REFRIGERANT R-410A WLL-MOUNT -TON IR CONDITIONERS J7 - Right Side Control Panel J7L - Left Side Control Panel, 9.5 EER Hz Solair Wall-Mount ir Conditioner is a self contained energy efficient system, which is designed to

More information

Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed.

Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed. THE WALL-MOUNT AIR CONDITIONERS -. EER, (HZ) Models WAA to W72AA Right-Side Control Panel Models WLA to W72LA Left-Side Control Panel. to Ton (7, to 7, Btuh) Green Refrigerant R-4A The Bard Wall-Mount

More information

The Wall-Mount Step Capacity Gas/Electric - WG*S Series Integrated Part Load Value (IPLV) Efficiency Up to 15.6 BTU/WATT.

The Wall-Mount Step Capacity Gas/Electric - WG*S Series Integrated Part Load Value (IPLV) Efficiency Up to 15.6 BTU/WATT. The Wall-Mount Step Capacity Gas/Electric - WG*S Series Integrated Part Load Value (IPLV) Efficiency Up to 15.6 BTU/WATT WG3S2, WG4S2, WG5S2 6HZ 24, to 56,5 BTUH Cooling Capacity 37, to 12,5 BTUH Heating

More information

Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed.

Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed. THE WALL-MOUNT AIR CONDITIONER -. EER, (HZ) Models WAA to W7AA Right-ide Control Panel Models WLA to W7LA Left-ide Control Panel. to Ton (7, to 7, Btuh) The Bard Wall-Mount Air Conditioner is a self contained

More information

THE WALL-MOUNT GAS/ELECTRIC - WG-SERIES

THE WALL-MOUNT GAS/ELECTRIC - WG-SERIES THE WALL-MOUNT GASELECTRIC - WG-SERIES WG - SERIES to Ton 3, to 6, BTUH Capacity 1, to 1, BTUH Heating Input 6HZ The Bard Wall-Mount Electric Air Conditioner with gas fired heating is a self contained

More information

I-TEC TM I30H-I60H 2-Stage Compressor High Efficiency Air Source Heat Pumps

I-TEC TM I30H-I60H 2-Stage Compressor High Efficiency Air Source Heat Pumps I-TEC TM IH-IH 2-Stage Compressor High Efficiency Air Source Heat Pumps Cooling Capacities: 20,0 to 55,000 Btuh Heating Capacities: 20,200 to 54,500 Btuh The Bard I-TEC Indoor Heat Pump system is designed

More information

GREEN REFRIGERANT R-410A

GREEN REFRIGERANT R-410A THE WALL-MOUNT STEP CAPACITY AIR CONDITIONERS Integrated Part Load Value (IPLV) Efficiency Up To. BTU/WATT WAS WAS Right Side Control Panel WLS WLS Left Side Control Panel to Ton (,4 to, Btuh) Hz GREEN

More information

V High Efficiency Series

V High Efficiency Series UNIT DISCONNECT(S) BEHIND THIS PANAL Commercial HVAC V High Efficiency Series Wallmount Air Conditioners PERFORMANCE: Efficiency rating of 9.0/9.5 EER Electric heat available from 5 kw to 18 kw Designed

More information

GREEN REFRIGERANT R-410A

GREEN REFRIGERANT R-410A s J7L to JL. to Ton (, to, Btuh) Left ide Control Panel Hz olair Wall-Mount ir Conditioner is a self contained energy efficient system, which is designed to offer maximum indoor comfort at a minimal cost

More information

REPLACEMENT PARTS MANUAL

REPLACEMENT PARTS MANUAL REPLACEMENT PARTS MANUAL W4H-A W4H-B W4H-C WALL MOUNTED PACKAGED HEAT PUMPS W4HDA W4HDB W4HDC W4H-A W4H-B W4H-C Models: W4HDA W4HDB W4HDC W0H-A W0H-B W0H-C W0HDA W0HDB W0HDC General Notes Revised and/or

More information

WALL MOUNTED PACKAGE HEAT PUMPS REPLACEMENT PARTS MANUAL. Models: S38H1 W38H1 S43H1 W43H1 S49H1 W49H1 S61H1 W61H1 S38H1D S43H1D S49H1D S61H1D

WALL MOUNTED PACKAGE HEAT PUMPS REPLACEMENT PARTS MANUAL. Models: S38H1 W38H1 S43H1 W43H1 S49H1 W49H1 S61H1 W61H1 S38H1D S43H1D S49H1D S61H1D REPLACEMENT PARTS MANUAL General Notes WALL MOUNTED PACKAGE HEAT PUMPS Models: SH WH SH WH SH WH SH WH SHD SHD SHD SHD Contents Revised and/or additional pages may be issued from time to time. Page A complete

More information

CHP

CHP Packaged Unit Heat Pump CHP16-024-030-036-048-060 2-5 Ton Cooling 23,000-57,500 Btuh Heating 12,800-85,300 Btuh (5-25 kw) Optional Electric Heating FEATURES Designed for outdoor rooftop or ground level

More information

REPLACEMENT PARTS MANUAL

REPLACEMENT PARTS MANUAL REPLACEMENT PARTS MANUAL W30H-A W30H-B W30H-C WALL MOUNTED PACKAGED HEAT PUMP W30HDA W30HDB W30HDC Models: W36H-A W36H-B W36H-C W36HDA W36HDB W36HDC General Notes Revised and/or additional pages may be

More information

ELITE SERIES R-410A Ready - Multi-Position

ELITE SERIES R-410A Ready - Multi-Position PRODUCT SPECIFICATIONS AIR HANDLERS CBXM ELITE SERIES R-0A Ready - Multi-Position Bulletin No. 0 October 07 Supersedes June 0 Nominal Capacity -. to Tons Optional Electric Heat -. to 0 kw MODEL NUMBER

More information

REPLACEMENT PARTS MANUAL

REPLACEMENT PARTS MANUAL REPLACEMENT PARTS MANUAL WAA-C Wall-Mount Air Conditioner with 0- VFD-High Resistance Ground Kit NOTE: For installation guidance for the 0- kit, contact Bard Technical Services at () -0. Contents Description

More information

M-SERIES MHP4 MODEL NUMBER GUIDE 3 M HP F P 1 ELECTRIC HEAT PUMP PACKAGED UNITS REVISION CODE

M-SERIES MHP4 MODEL NUMBER GUIDE 3 M HP F P 1 ELECTRIC HEAT PUMP PACKAGED UNITS REVISION CODE ELECTRIC HEAT PUMP PACKAGED UNITS MHP4 FORM NO. MHP4-100 (10/2018) MODEL NUMBER GUIDE 3 M HP 4 11 18 1 F P 1 FACTORY INSTALLED ELECTRIC HEAT 3= 3 KW 5 = 5 KW 7 = 7 KW 10 = 10 KW M = MAGIC-PAK HP = HEAT

More information

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Single stage cooling capacity control on all 0 241 models Two stage cooling capacity control on

More information

Product Data. Features/Benefits. Omnizone 50XCA06-14 Air-Cooled Indoor Self-Contained Systems with Puron Refrigerant (R-410A) 5 to 12 Nominal Tons

Product Data. Features/Benefits. Omnizone 50XCA06-14 Air-Cooled Indoor Self-Contained Systems with Puron Refrigerant (R-410A) 5 to 12 Nominal Tons Product Data Omnizone 50XCA06-14 Air-Cooled Indoor Self-Contained Systems with Puron Refrigerant (R-410A) 5 to 1 Nominal Tons The 50XCA single-package cooling units with integral air-cooled condensers

More information

Product Data. Features/Benefits. OMNIZONE 50XCR06-24 Remote Air-Cooled Indoor Self-Contained Systems with PURON Refrigerant (R-410A)

Product Data. Features/Benefits. OMNIZONE 50XCR06-24 Remote Air-Cooled Indoor Self-Contained Systems with PURON Refrigerant (R-410A) Product Data OMNIZONE 50XCR06-24 Remote Air-Cooled Indoor Self-Contained Systems with PURON Refrigerant (R-410A) 5 to 20 Nominal Tons The 50XCR single-package remote aircooled units offer: Compact, durable,

More information

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO technical sales guide - 60Hz Taurus R Ducted Split Units UPTO HIGH AMBIENT OPERATION 52 O C Page CONTENTS Nomenclature.. 2 Description. 3 Features.. 3 Product Data. 4 Condensing Unit Cooling Performance

More information

DESCRIPTION FEATURES

DESCRIPTION FEATURES SPLIT-SYSTEM AIR COOLED CONDENSING UNIT H5CE150, H5CE180 AND H5CE240 12-1/2, 15 AND 20 NOMINAL TONS (World 50Hz) DESCRIPTION These outdoor condensing units are completely assembled, piped and wired at

More information

RPHP13. Product Specifications. 13 SEER Heat Pump Residential Packaged Unit. Refrigerant System. Cabinet Construction. Blower. Controls.

RPHP13. Product Specifications. 13 SEER Heat Pump Residential Packaged Unit. Refrigerant System. Cabinet Construction. Blower. Controls. RPHP13 Product Specifications Refrigerant System Environmentally friendly R410A refrigerant Copper tubing with enhanced fin coils External service gauge ports 13 SEER Heat Pump Residential Packaged Unit

More information

RCE13. Product Specifications. 13 SEER Electric / Electric Residential Packaged Unit. Refrigerant System. Cabinet Construction. Blower.

RCE13. Product Specifications. 13 SEER Electric / Electric Residential Packaged Unit. Refrigerant System. Cabinet Construction. Blower. RCE13 Product Specifications 13 SEER Electric / Electric Residential Packaged Unit Form No. RCE13-100 (04/2013) Refrigerant System Environmentally friendly R410A refrigerant Copper tubing with enhanced

More information

Q3RD Series. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

Q3RD Series. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS TECHNICAL SPECIFICATIONS Q3RD Series Single Packaged Heat Pump, Single Phase Q3RD-13 SEER 2 thru 4 Ton Units Cooling: 24,000 to 48,000 Btuh Heating: 23,200 to 48,000 Btuh The Q3 Series single packaged

More information

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS FEATURES DESCRIPTION. H5CE090 & H3CE AND 10 NOMINAL TONS (World 50HZ)

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS FEATURES DESCRIPTION. H5CE090 & H3CE AND 10 NOMINAL TONS (World 50HZ) 550.39-TG1YI (994) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS H5CE090 & H3CE120 7.5 AND 10 NOMINAL TONS (World 50HZ) HCE090 SUNLINE 2000 DESCRIPTION These Sunline 2000 units are completely assembled, piped

More information

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11. TECHNICAL SPECIFICATIONS Q6SP Series Rev A 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.0 EER Commercial Systems Meet or Exceed ASHRAE 90.1-2010 These 7½ and 10 ton units are designed

More information

Q6SP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

Q6SP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11. TECHNICAL SPECIFICATIONS Q6SP Series 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.0 EER Commercial Systems Meet or Exceed ASHRAE 90.1 These 7½ and 10 ton units are designed specifically

More information

D M S 760 C01 A A 1 1

D M S 760 C01 A A 1 1 CONTENTS Description Features Options Available Selection Method Product Data Cooling Performance Data (85 F Ambient Cooling Performance Data (95 F Ambient) Cooling Performance Data (105 F Ambient)..............................

More information

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS 550.13-TG1Y(98) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS HCA300, 360, 80 & 600 5 THRU 50 NOMINAL TONS HCA80 DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece

More information

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS 50Hz Single Package Rooftop, Cooling Only with Puronr (R---410A) Refrigerant One Stage Cooling Capacity Control: Size 07 Two Stage Cooling Capacity Control: Sizes 08, 09, 12 & 14 Submittal Data PERFORMANCE

More information

Q5RD Series Single Packaged Heat Pump, Single Phase

Q5RD Series Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS Q5RD Series Single Packaged Heat Pump, Single Phase 13 SEER, R-410A 2 thru 5 Ton Units Cooling: 24,000 to 56,000 Btuh Heating: 24,000 to 54,500 Btuh The Q5 Series single packaged

More information

PHR5. Product Specifications

PHR5. Product Specifications PHR5 Product Specifications UP to 15.5 SEER, UP to 12.5 EER, PACKAGE HEAT PUMP UNITS, 2 5 TONS 208/230 Volt, 1 phase, 60 Hz 208/230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally balanced R

More information

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS TECHNICAL SPECIFICATIONS S5BP Series Split System Air Conditioner 71/2 Ton Energy Star rated at 11.7 EER and 11.8 IEER 10 Ton rated at 11.2 EER and 11.5 IEER R-410A Refrigerant The S5BP Series of air conditioners

More information

Product Data. Features/Benefits 50JS SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS)

Product Data. Features/Benefits 50JS SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS) SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS) Product Data UNIT (50 Hz) Single-packaged Heat Pump for Residential and Light Commercial applications. Features/Benefits One-piece

More information

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H4CE090 & H2CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H4CE090 & H2CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS 550.23-TG1Y (595) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS H4CE090 & H2CE120 & H1CE150 7-1/2, 10, & 12-1/2 NOMINAL TONS 8.9-9.5 EER SUNLINE 2000 HCE090 208/230/460 VOLT ONLY 208/230/575 VOLT ONLY DESCRIPTION

More information

AIR HANDLERS RBHM- SERIES AIR HANDLERS AND FAN COIL UNIT

AIR HANDLERS RBHM- SERIES AIR HANDLERS AND FAN COIL UNIT FORM NO. H11-521 AIR HANDLERS earth friendly refrigerant RBHM- SERIES AIR HANDLERS AND FAN COIL UNIT Features Versatile 3-way convertible design for upflow, horizontal left and horizontal right. Available

More information

Tons BTU/h S.E.E.R* E.E.R** HSPF

Tons BTU/h S.E.E.R* E.E.R** HSPF SOUND REFRIGERANT ENVIRONMENTALLY PHD3 Product Specifications 13 SEER, R -410A PACKAGE HEAT PUMP, 2½ to 5 TONS 3 -Phase, 208/230-3 -60 and 460-3 -60 REFRIGERATION CIRCUIT R--410A refrigerant Copper tube/aluminum

More information

AIR HANDLERS UBHN- SERIES AIR HANDLERS AND FAN COIL UNIT PRELIMINARY NOT FOR DISTRIBUTION

AIR HANDLERS UBHN- SERIES AIR HANDLERS AND FAN COIL UNIT PRELIMINARY NOT FOR DISTRIBUTION FORM NO. H22-522 AIR HANDLERS earth friendly refrigerant PRELIMINARY NOT FOR DISTRIBUTION UBHN- SERIES AIR HANDLERS AND FAN COIL UNIT Features Versatile 3-way convertible design for upflow, horizontal

More information

Contents. Control Panel. Control Panel. Blower Housing. Bard Manufacturing Company, Inc. Bryan, Ohio 43506

Contents. Control Panel. Control Panel. Blower Housing. Bard Manufacturing Company, Inc. Bryan, Ohio 43506 REPLACEMENT PARTS MANUAL WALL MOUNTED PACKAGE HEAT PUMPS Models: W4H W4HD W4H W4HD W0H W0HD General Notes Revised and/or additional pages may be issued from time to time. A complete and current manual

More information

13 SEER. Light Commercial 3 Phase Packaged Heat Pump. RHP13 Features and Benefits. Refrigerant System. Cabinet Construction. Blower.

13 SEER. Light Commercial 3 Phase Packaged Heat Pump. RHP13 Features and Benefits. Refrigerant System. Cabinet Construction. Blower. 13 SEER Light Commercial 3 Phase Packaged Heat Pump RHP13 Features and Benefits Form No. AC-RHP13-100 (05/2013) Refrigerant System Environmentally friendly R410A refrigerant Copper tubing with enhanced

More information

PCB COMMERCIAL SERIES

PCB COMMERCIAL SERIES PCB COMMERCIAL SERIES 50 Hz SELF-CONTAINED PACKAGE CONDITIONER 7½, 0, AND 5 TON [6.4 kw to 5.8 kw] COOLING CAPACITY: 90,000 TO 80,000 BTU/H The PCB Commercial 50 Hz self-contained packaged air conditioner

More information

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS 50FP-1SB 50FP034, 038, 044, 048, 054, 064, 074 SINGLE-PACKAGE COOLING UNITS CONSTANT/VARIABLE VOLUME PRODUCT INTEGRATED CONTROLS CARRIER COMFORT NETWORK COMPATIBLE FACTORY-INSTALLED OPTIONAL ELECTRIC HEAT

More information

REPLACEMENT PARTS MANUAL

REPLACEMENT PARTS MANUAL REPLACEMENT PARTS MANUAL WALL MOUNTED PACKAGED HEAT PUMP Models: W18H-A W4H-A W4H-B W4H-C W4HDA W4HDB W4HDC General Notes Revised and/or additional pages may be issued from time to time. A complete and

More information

PACKAGE AIR CONDITIONERS

PACKAGE AIR CONDITIONERS PACKAGE AIR CONDITIONERS FORM NO. S22-92 REV. 2 Supersedes Form No. S22-92 Rev. RLNA- SUPER HIGH EFFICIENCY SERIES NOMINAL SIZES -5 TONS [0.6-7.6 kw] *Unit shown with optional louver panels installed..0

More information

9 EER Units Air Conditioners (Standard RH) Page # 3 Air Conditioner Heat Kits (Standard RH) Page # 4

9 EER Units Air Conditioners (Standard RH) Page # 3 Air Conditioner Heat Kits (Standard RH) Page # 4 9 EER Units Air Conditioners (Standard RH) Page # 3 Air Conditioner Heat Kits (Standard RH) Page # 4 (Field Installed) Air Conditioners (Left Hand) Page # 6 Air Conditioner Heat Kits (Left Hand) Page #

More information

A I R H A N D L E R S CB26UH-R. MERIT Series R-22 - Upflow / Horizontal P R O D U C T S P E C I F I C AT I O N S

A I R H A N D L E R S CB26UH-R. MERIT Series R-22 - Upflow / Horizontal P R O D U C T S P E C I F I C AT I O N S P R O D U C T S P E C I F I C AT I O N S A I R H A N D L E R S CB6UH-R MERIT Series R- - Upflow / Horizontal Bulletin No. 1067 April 01 Supersedes January 01 Nominal Capacity - 1.5 to 5 Tons Optional Electric

More information

TECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW

TECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW MODELS: D4HH 024 THRU 180 York horizontal ductable air conditioning packages offer a complete line of

More information

S6BQ Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Split System 2-Stage Air Conditioner. 7 1/2 and 10 Ton rated at 11.2 EER and 12.

S6BQ Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Split System 2-Stage Air Conditioner. 7 1/2 and 10 Ton rated at 11.2 EER and 12. TECHNICAL SPECIFICATIONS S6BQ Series Split System 2-Stage Air Conditioner 7 1/2 and 10 Ton rated at 11.2 EER and 12.9 IEER The S6BQ Series of air conditioners offers exceptional performance. The unit,

More information

GQ5RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase 13 SEER, R-410A, WARRANTY

GQ5RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase 13 SEER, R-410A, WARRANTY TECHNICAL SPECIFICATIONS GQ5RD Series Single Packaged Heat Pump, Single Phase 13 SEER, R-410A, 2 thru 5 Ton Units Cooling: 24,000 to 56,000 Btuh Heating: 24,000 to 54,500 Btuh The GQ5 Series single packaged

More information

GPC14H. 2- to 5-Ton Packaged Air Conditioner 14 SEER. Cooling Capacity: 24,000-57,500 BTU/H

GPC14H. 2- to 5-Ton Packaged Air Conditioner 14 SEER. Cooling Capacity: 24,000-57,500 BTU/H H Cooling Capacity: 24,000-57,500 BTU/H 2- to 5-Ton Packaged Air Conditioner 14 SEER Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data... 4 Airflow Data... 16 Heater Kit Specifications...

More information

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES FFMA Base Series Fan Coil Sizes 018 thru 037 Product Data A13417 FEATURES The FFMA Series Fan Coil unit is primarily designed for apartment applications as an upflow only indoor fan coil for split -system

More information

GQ5RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase 13 SEER, R-410A, WARRANTY

GQ5RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase 13 SEER, R-410A, WARRANTY TECHNICAL SPECIFICATIONS GQ5RD Series Single Packaged Heat Pump, Single Phase 13 SEER, R-410A, 2 thru 5 Ton Units Cooling: 24,000 to 56,000 Btuh Heating: 24,000 to 54,500 Btuh The GQ5 Series single packaged

More information

P3RC-12 SEER 2 Ton thru 4 Ton Units Cooling: 23,800 to 48,000 Btuh

P3RC-12 SEER 2 Ton thru 4 Ton Units Cooling: 23,800 to 48,000 Btuh TECHNICAL SPECIFICATIONS P3R(A,C) Series Single Packaged Air Conditioner, Single Phase P3RA-10 SEER 2 thru 5 Ton Units Cooling: 24,000 to 59,000 Btuh P3RC-12 SEER 2 Ton thru 4 Ton Units Cooling: 23,800

More information

AIR HANDLERS RBHK- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT

AIR HANDLERS RBHK- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT FORM NO. H11-516 REV. 1 Supersedes Form No. H11-516 Rev. 0 AIR HANDLERS RBHK- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT Features Versatile 4-way convertible design for upflow, downflow, horizontal

More information

AFGP12B. Features. Efficiency: 12 SEER 80% AFUE. Warranty: 10-year limited compressor 10-year limited heat exchanger 5-year limited components

AFGP12B. Features. Efficiency: 12 SEER 80% AFUE. Warranty: 10-year limited compressor 10-year limited heat exchanger 5-year limited components AFGP12B Gas/Electric Package Unit Features Shipped for horizontal applications; easily converted to downshot Side-by-side horizontal discharge Standard thermostatic expansion valve Crimp-Tite weld-free

More information

CFM (L/s) Dimensions. Filter Size in. Ship Wt. H x W x D in. (mm) 1800A 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

CFM (L/s) Dimensions. Filter Size in. Ship Wt. H x W x D in. (mm) 1800A 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15 ENVIRONMENTALLY SOUND REFRIGERANT FMA4X, FMA4P Product Specifications APARTMENT FAN COILS ALL MODELS 1 1/2, 2, 2 1/2, and 3 Tons Upflow application only Accessory field installed electric heat kits available

More information

CONVERTIBLE SINGLE PACKAGE HEAT PUMP

CONVERTIBLE SINGLE PACKAGE HEAT PUMP PHA D SERIES UNITARY AIRCONDITIONING MANUFACTURER CERTIFIED TO ARI AS COMPLYING WITH ARI EQUIPMENT STANDARD 210 CONVERTIBLE SINGLE PACKAGE HEAT PUMP FEATURE SINGLE PACKAGE, 2 THRU 5 TON COOLING Single

More information

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: 036-21323-001-B-0202 GENERAL SPECIFICATIONS OUTDOOR UNIT: Two independent refrigerant circuits Inherently protected fan motors Two independent scroll compressors V-Coil Design Exterior service port connections

More information

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C PH120 R410a Refrigerant Rooftop Packaged INDOOR COIL ENTERING AIR TEMP 0 c DB WB 21 23 25 27 29 31 PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C 30 35 40 45 Cap Cap Cap Cap 17 115.3 70.7 11.5

More information

Factory Option Codes L M E S P R D V F F H E

Factory Option Codes L M E S P R D V F F H E I N D O O R A I R Q U A L I T Y P R O D U C T S P E C I F I C AT I O N S ENERGY RECOVERY SYSTEM FOR L-SERIES ROOFTOP UNITS - 60 HZ Bulletin No. 10533 January 011 Supersedes October 010 800 to 600 cfm Capacity

More information

ENERGY RECOVERY SYSTEM 60 HZ

ENERGY RECOVERY SYSTEM 60 HZ I N D O O R A I R Q U A L I T Y E N G I N E E R I N G D A T A ENERGY RECOVERY SYSTEM 60 HZ Bulletin No. 210517 April 2008 Supersedes 210368 April 2007 300 to 6200 cfm Capacity MODEL NUMBER IDENTIFICATION

More information

RPGE13. Product Specifications. 13 SEER Gas / Electric Residential Packaged Unit. Refrigerant System. Heat Exchanger. Cabinet Construction.

RPGE13. Product Specifications. 13 SEER Gas / Electric Residential Packaged Unit. Refrigerant System. Heat Exchanger. Cabinet Construction. RPGE13 Product Specifications 13 SEER Gas / Electric Residential Packaged Unit Form No. RPGE13-100 (04/2013) Refrigerant System Environmentally friendly R410A refrigerant Copper tubing with enhanced fin

More information

GPC14H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER

GPC14H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER Cooling Capacity: 24,000-57,500 BTU/H H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data... 5 Airflow Data... 18 Heater Kit

More information

FSH1BG Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Ultra High Efficiency Heat Pump, Up to 19 SEER Residential System 2-5 Ton Capacities

FSH1BG Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Ultra High Efficiency Heat Pump, Up to 19 SEER Residential System 2-5 Ton Capacities TECHNICAL SPECIFICATIONS FSH1BG Series Ultra High Efficiency Heat Pump, Up to 19 SEER Residential System 2-5 Ton Capacities The iq Drive heat pump system features modulating compressor technology and variable

More information

Q7RE Series Single Packaged Heat Pump, Single Phase

Q7RE Series Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS Q7RE Series Single Packaged Heat Pump, Single Phase 14 SEER, 8.0 HSPF 2 thru 5 Ton Units Cooling: 23,400 to 55,500 Btuh Heating: 21,800 to 56,000 Btuh The Q7 Series single packaged

More information

Q7RE Series Single Packaged Heat Pump, Single Phase

Q7RE Series Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS Q7RE Series Single Packaged Heat Pump, Single Phase 14 SEER, 8.0 HSPF 2 thru 5 Ton Units Cooling: 23,400 to 55,500 Btuh Heating: 21,800 to 56,000 Btuh The Q7 Series single packaged

More information

CFM (L/s) Min Max 450 (212) 600 (283) 750 (354) Dimensions H x W x D in. (mm) 675 (319) 36 1/2 x 20 1/2 x (425)

CFM (L/s) Min Max 450 (212) 600 (283) 750 (354) Dimensions H x W x D in. (mm) 675 (319) 36 1/2 x 20 1/2 x (425) ENVIRONMENTALLY SOUND REFRIGERANT FMA4P Product Specifications APARTMENT FAN COILS ALL MODELS 1 1/2, 2, 2.5, and 3 Tons Upflow application only For use with R 410A refrigerant or R 22 with accessory TXV

More information

P5RF Series Rev "A" Single Packaged Air Conditioner Single Phase

P5RF Series Rev A Single Packaged Air Conditioner Single Phase TECHNICAL SPECIFICATIONS P5RF Series Rev "A" Single Packaged Air Conditioner Single Phase 15 SEER, 12 EER, R-410A 2 thru 5 Ton Units Cooling: 24,000 to 57,500 Btuh The P5 Series single packaged air conditioners

More information

Q6SE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase

Q6SE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS Q6SE Series Single Packaged Heat Pump, Single Phase Q6SE-14 SEER, 8.0 HSPF 2-5 Ton Units Cooling: 23,000 to 58,000 Btuh Heating: 22,800 to 59,000 Btuh The Q6 Series single packaged

More information

13 SEER Light Commercial 3 Phase

13 SEER Light Commercial 3 Phase 13 SEER Light Commercial 3 Phase Packaged Gas / Electric RGE13 Features and Benefits Form No. AC-RGE13-100 (04/2013) Refrigerant System Environmentally friendly R410A refrigerant Copper tubing with enhanced

More information

MCE4 MCE4. Electric Heating / Electric Cooling Packaged Thru-the-Wall Units

MCE4 MCE4. Electric Heating / Electric Cooling Packaged Thru-the-Wall Units MCE4 Electric Heating / Electric Cooling Packaged Thru-the-Wall Units Form No.: MCE4-100 (07/2011) features Up to 10.4 EER cooling efficiency Completely self-contained heating and cooling package No outside

More information

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ DESCRIPTION FEATURES

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ DESCRIPTION FEATURES (791) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ H1CE180 & 240 15 AND 20 NOMINAL TONS (60 HZ) 13 AND 17-1/2 NOMINAL TONS (50 HZ) SUNLINE 2000 DESCRIPTION These Sunline 2000 units are completely

More information

AIR HANDLERS AIR HANDLERS. RHPN- SERIES 18 SEER featuring Earth-Friendly R-410A Refrigerant. Features

AIR HANDLERS AIR HANDLERS. RHPN- SERIES 18 SEER featuring Earth-Friendly R-410A Refrigerant. Features FORM NO. H11-528 Supersedes Form No. H11-526 Rev. 1 AIR HANDLERS AIR HANDLERS RHPN- SERIES 18 SEER featuring Earth-Friendly R-410A Refrigerant Features earth friendly refrigerant Includes an energy efficient

More information

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINTS

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINTS 50FN-1SB 50FNX,FNY078,088,104 SINGLE-PACKAGE COOLING UNITS CONSTANT/VARIABLE AIR VOLUME PRODUCT INTEGRATED CONTROLS CARRIER COMFORT NETWORK COMPATIBLE WITH INTEGRAL ECONOMIZER AND HIGH-CAPACITY MODULATING

More information

CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) 1800Aǂ 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) 1800Aǂ 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15 ENVIRONMENTALLY SOUND REFRIGERANT FMA4X, FMA4P Product Specifications APARTMENT FAN COILS ALL MODELS 1 1/2, 2, 2 1/2, and 3 Tons Upflow application only Accessory field installed electric heat kits available

More information

GQ3RD Series. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS

GQ3RD Series. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS GQ3RD Series Single Packaged Heat Pump, Single Phase GQ3RD-13 SEER 2 thru 4 Ton Units Cooling: 24,000 to 48,000 Btuh Heating: 23,200 to 48,000 Btuh The GQ3 Series single packaged

More information

CFM (L/s) Dimensions. Filter Size Ship Wt. HxWxDin.(mm) 1800Aǂ 1-1/2 18, (212) 675 (319) 36-1/2 x 20-1/2 x (45) FMA4P (928 x 521 x 381)

CFM (L/s) Dimensions. Filter Size Ship Wt. HxWxDin.(mm) 1800Aǂ 1-1/2 18, (212) 675 (319) 36-1/2 x 20-1/2 x (45) FMA4P (928 x 521 x 381) FMA4X, FMA4P Product Specifications APARTMENT FAN COILS ALL MODELS 1-1/2, 2, 2-1/2, and 3 Tons Upflow application only Accessory field- installed electric heat kits available in, 7., or 10 kw 208/230-1-

More information

The Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat

The Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat Producing Quality Heating & Cooling Equipment For Over 50 Years CEA SERIES CEILING EPOSED HORIZONTAL FAN COIL UNITS The Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat

More information

14 SEER R -410A PACKAGE GAS / ELECTRIC UNIT 2 to 5 TON

14 SEER R -410A PACKAGE GAS / ELECTRIC UNIT 2 to 5 TON 14 SEER R -410A PACKAGE GAS / ELECTRIC UNIT 2 to 5 TON Two -Stage Gas Heating/Two -Stage Electric Cooling REFRIGERATION CIRCUIT All models are equipped with high efficiency two--stage Copeland UltraTech

More information

DESCRIPTION SINGLE PACKAGE HEAT PUMP UNITS BCB 036, 048 & BTG-A-0506

DESCRIPTION SINGLE PACKAGE HEAT PUMP UNITS BCB 036, 048 & BTG-A-0506 TECHNICAL GUIDE SINGLE PACKAGE HEAT PUMP UNITS BCB 036, 048 & 060 3, 4 & 5 NOMINAL TONS 10.0 SEER DESCRIPTION BCB Series heat pumps are convertible single package units with a common cabinet and a common

More information

WALL MOUNTED PACKAGE HEAT PUMPS REPLACEMENT PARTS MANUAL. Models: S38H1 W38H1 S43H1 W43H1 S49H1 W49H1 S61H1 W61H1. General Notes. Contents.

WALL MOUNTED PACKAGE HEAT PUMPS REPLACEMENT PARTS MANUAL. Models: S38H1 W38H1 S43H1 W43H1 S49H1 W49H1 S61H1 W61H1. General Notes. Contents. REPLACEMENT PARTS MANUAL WALL MOUNTED PACKAGE HEAT PUMPS Models: SH WH SH WH SH WH SH WH General Notes Contents Revised and/or additional pages may be issued from time to time. Page A complete and current

More information

Models: W30A2, W36A2. Contents. Control Panel. Blower Assembly. Bard Manufacturing Company, Inc. Bryan, Ohio 43506

Models: W30A2, W36A2. Contents. Control Panel. Blower Assembly. Bard Manufacturing Company, Inc. Bryan, Ohio 43506 REPLACEMENT PARTS MANUAL WALL MOUNTED PACKAGE AIR CONDITIONER Models: W30A, W36A General Notes Revised and/or additional pages may be issued from time to time. A complete and current manual consists of

More information

PA95 12 SEER FEATURES 2 THRU 4 TON SINGLE PACKAGE

PA95 12 SEER FEATURES 2 THRU 4 TON SINGLE PACKAGE PACKAGE AIR CONDITIONER PA95 12 SEER C 2 THRU 4 TON SINGLE PACKAGE FEATURES CONSTRUCTED FOR DURABILITY All panels made from galvanized steel pre--coated inside and out -- using a polyester top coat, on

More information

GP7RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner, Single Phase WARRANTY

GP7RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner, Single Phase WARRANTY TECHNICAL SPECIFICATIONS GP7RD Series Single Packaged Air Conditioner, Single Phase GP7RD 13 SEER, R-410A 2 thru 4 Ton Units Cooling: 24,000 to 47,000 Btuh The GP7 Series single packaged air conditioners

More information

10 EER Units Air Conditioners (Standard RH) Page # 3 Air Conditioner Heat Kits (Standard RH) Page # 4

10 EER Units Air Conditioners (Standard RH) Page # 3 Air Conditioner Heat Kits (Standard RH) Page # 4 Units Air Conditioners (Standard RH) Page # 3 Air Conditioner Heat Kits (Standard RH) Page # 4 (Field Installed) Air Conditioners (Left Hand) Page # 6 Air Conditioner Heat Kits (Left Hand) Page # 7 (Field

More information

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units 11.0 EER

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units 11.0 EER TECHNICAL SPECIFICATIONS Q6SP Series Rev A 7.5 and 10 Ton Packaged Electric Heat Pump Units 11.0 EER Commercial Systems Meet or Exceed ASHRAE 90.1-2010 These 7½ and 10 ton units are designed specifically

More information

P6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Electric Cooling Units EER Commercial System Units

P6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Electric Cooling Units EER Commercial System Units TECHNICAL SPECIFICATIONS P6SP Series Rev A 6, 7½ and 10 Ton Packaged Electric Cooling Units 11.2 EER Commercial System Units These units are designed specifically for retrofit applications and compatibility

More information

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES FFMA Base Series Fan Coil Sizes 018 thru 037 Product Data A13417 FEATURES The FFMA Series Fan Coil unit is primarily designed for apartment applications as an upflow only indoor fan coil for split -system

More information

S3BN Series Split System Air Conditioner 10.3 EER Commercial System 7½ and 10 Ton Capacity R-22 Refrigerant

S3BN Series Split System Air Conditioner 10.3 EER Commercial System 7½ and 10 Ton Capacity R-22 Refrigerant TECHNICAL SPECIFICATIONS S3BN Series Split System Air Conditioner 10.3 EER Commercial System 7½ and 10 Ton Capacity R-22 Refrigerant The S3BN Series of air conditioners offers exceptional performance from

More information

DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS D(CE, CG) 036, 048, 060 & YTG-A-0207

DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS D(CE, CG) 036, 048, 060 & YTG-A-0207 TECHNICAL GUIDE SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS D(CE, CG) 036, 048, 060 & 072 3, 4, 5 & 6 NOMINAL TONS 10.0 SEER (3, 4, & 5 Ton), 9.0 EER (6 Ton) DESCRIPTION YORK

More information

REFRIGERANT SYSTEM R410A Refrigerant High efficiency compressor Copper tubing with enhanced fin coils

REFRIGERANT SYSTEM R410A Refrigerant High efficiency compressor Copper tubing with enhanced fin coils MHP4 Electric Heat Pump Packaged Thru-the-Wall Units FEATURES Up to 10.4 EER cooling efficiency Completely self-contained heating and cooling package No outside condensing unit No external refrigerant

More information

FORM NO. PTZ-806 REV. 1 HEAT PUMPS

FORM NO. PTZ-806 REV. 1 HEAT PUMPS FORM NO. PTZ-806 REV. 1 TZPLS-14 SERIES Efficiencies: 15 SEER/12.5 EER 9 HSPF Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to 17.7 kw] Manufactured for Thermal

More information

i Series Model SV Water Source Heat Pump 1/2 to 6 Ton

i Series Model SV Water Source Heat Pump 1/2 to 6 Ton i Series Model SV Water Source Heat Pump 1/2 to 6 Ton Engineering Submittal Sheet Overview and Certifications Standard Features, Factory Installed Options, and Field Installed Accessories Standard Features

More information

AIR HANDLERS RBHC- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT

AIR HANDLERS RBHC- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT FORM NO. H11-517 REV. 1 Supersedes Form No. H11-509 Rev. 7 AIR HANDLERS RBHC- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT Features 1 1 /2 ton [5.3 kw] through 5 ton [17.6 kw] models are always just

More information

TECHNICAL GUIDE FLEXIBLE LIGHT COMMERCIAL UNIT CHAMPION SERIES (WORLD 50 HZ) SINGLE PACKAGE COOLING UNITS D1EB036, 048 AND 060 3, 4 & 5 NOMINAL TONS

TECHNICAL GUIDE FLEXIBLE LIGHT COMMERCIAL UNIT CHAMPION SERIES (WORLD 50 HZ) SINGLE PACKAGE COOLING UNITS D1EB036, 048 AND 060 3, 4 & 5 NOMINAL TONS TECHNICAL GUIDE CHAMPION SERIES (WORLD 50 HZ) SINGLE PACKAGE COOLING UNITS D1EB036, 048 AND 060 3, 4 & 5 NOMINAL TONS FLEXIBLE LIGHT COMMERCIAL UNIT GENERAL York s Champion package units are designed to

More information

SUNLINE 2000 (WORLD 50 HZ)

SUNLINE 2000 (WORLD 50 HZ) 530.26-TG1YI (298) SINGLE PACKAGE AIR-COOLED AIR CONDITIONERS D3CE 036, 048, 060 & 076 D5CG 036, 048, 060 & 076 3, 4, 5 AND 6 NOMINAL TONS SHOWN SUNLINE 2000 (WORLD 50 HZ) DESCRIPTION YORK Sunline 2000

More information

REPLACEMENT PARTS MANUAL

REPLACEMENT PARTS MANUAL REPLACEMENT PARTS MANUAL WALL MOUNTED PACKAGED AIR CONDITIONER Models: W1AA-A WAA-A WAA-B WAA-C WAA-D WAA-F General Notes Revised and/or additional pages may be issued from time to time. A complete and

More information