I-TEC TM I30H-I60H 2-Stage Compressor High Efficiency Air Source Heat Pumps

Size: px
Start display at page:

Download "I-TEC TM I30H-I60H 2-Stage Compressor High Efficiency Air Source Heat Pumps"

Transcription

1 I-TEC TM IH-IH 2-Stage Compressor High Efficiency Air Source Heat Pumps Cooling Capacities: 20,0 to 55,000 Btuh Heating Capacities: 20,200 to 54,500 Btuh The Bard I-TEC Indoor Heat Pump system is designed for classrooms and other similar applications demanding high efficiency and the lowest possible sound levels that are practical and achievable, and also accomodates the over-the-window sill requirement for many replacement projects on older school buildings. The I-TEC Series meets that challenge with many innovative design features resulting in a highly refined appearance while at the same time improving on the very important maintenance and serviceability features needed by the facilities maintenance and service staffs. I-TEC Standard Features Double wall construction, 20-ga. exterior skin, no visible fasteners No fiberglass insulation Hinged, lockable, removable doors Removable sides and modularized construction for transporting through standard doors or in elevators Suitable for any floor installations Can be installed in left or right corners with no modifications Non-corrosive drainpans with no standing water 2-Stage scroll compressors with discharge muffler, double floating isolation mounting system, and sound muffling cover R-4A Green Refrigerant Heating and cooling thermostatic expansion valves Extra large full width control panel for easy access to all controls Circuit Breakers on 2V models, and Toggle Disconnect on 4V Evaporator coils constructed with hydrophilic fin stock with the following advantages: Acrylic coating Wettable surface with low contact angle no bead-up condensate, lower wet-coil air-side pressure drop, improved draining & lower re-entrainment of moisture back into the air stream in continuous blower operating modes Antimicrobial properties provide microbial resistance to fungicidal growth Resistant to Mold and Mildew, ASTM D2373 no growth Seals fin surface against aluminum oxide formation 24VAC 75VA control transformer with circuit breaker 24VAC low-voltage terminal strip for thermostat or DDC control ECM indoor and outdoor motors Modulating outdoor fan motor and low ambient control Modulating indoor fan motor for constant CFM in different operating modes up to 0.50" ESP High and Low Pressure switches with lockout circuit Electronic heat pump control board with diagnostics Liquid line filter/drier Readily accessible service ports located behind locking hinged doors Pleated 2" MERV filter Designed for over-the-window sill wall penetration and has 3" vertical adjustment for wall sleeve attachment Units designed to be flush to a smooth interior wall and not require trim kits by use of adjustable wall sleeves; Trim Kits available where required Low sound levels are achieved by numerous system design innovations including special acoustical insulation Installation flexibility. Can be installed in corner applications with one side against a wall. Overflow detection system monitors indoor and out coil drain pans and shuts down compressor to prevent condensate overflow. Freezestat on indoor coil safeguards against indoor coil freeze up by shutting down the compressor. I-TEC Optional Features & Accessories Two Ventilation Options: Both ERV and CRV have ECM motors, filter system, and positive shut-off. Energy Recovery Ventilator (ERV) is designed for both modulating or fixed supply and exhaust airflow operation depending upon environmental controls used, and has positive shutoff on intake and exhaust sides when unoccupied. Modulating mode requires CO 2 controller, has intake rate that is higher than exhaust, and has optional minimum CFM to address building IAQ requirements. The system modulates to maintain selected maximum CO 2 level. Fixed mode can be used with thermostat or DDC that has a dedicated Occupied output that is ON during Occupied and OFF during Unoccupied. Intake and exhaust rates can be independently adjusted. Commercial Room Ventilator (CRV) is a fan powered ventilation package to manage intake & exhaust air at fixed rates but without energy recovery capability. The rates are: , are independently selectable, and has positive shutoff on intake and exhaust sides when unoccupied. Requires control system that has a dedicated ventilation control output to be ON during Occupied and OFF during Unoccupied. CO2 controller with ON/ OFF output relay can be used. Factory setting is 375 CFM balanced to meet pressurization requirements of ASHRAE. Accessories: Outdoor louver grilles: Clear, Medium Bronze, Dark Bronze Telescoping Wall Sleeves Wall Sleeve Ranges (wall thickness): 5.5" to.5", " to 3.5", 3" to 23.5" 3" and " Riser Platforms available if required Electric heat packages factory installed within the basic unit cabinet Accessories for Duct-Free and Ducted installations Other Options: Dehumidification (hot gas reheat) models Low Ampacity Models available Hot water coil packages, both Duct-Free and Ducted versions available. Form No S3-2 Supersedes S3-32 Page of

2 Specifications - 2½ through 3½ Ton MODELS IH-A IH-B IH-C I3H-A I3H-B I3H-C I42H-A I42H-B I42H-C ELECTRICAL RATING-- HZ 2/20-2/ /20-2/ /20-2/ Operating Voltage Range COMPRESSOR Volts 2/20-2/ /20-2/ /20-2/ Rated Load Amps (2/20).0/.5 7.4/ /3.5/ /5..0/ Branch Circuit Selection Current Locked Rotor Amps ENERGY RECOVERY VENTILATOR Volts 2/20-- 2/20-- 2/20-- Full Load Amps (3-motors) FAN MOTOR ECM Horsepower /3 /3 /3 Volts 2/20-- 2/20-- 2/20-- Full Load Amps CFM BLOWER MOTOR ECM Horsepower /3 /2 /2 Volts 2/20-- 2/20-- 2/20-- Full Load Amps rating points, will modulate based upon O.D. ambient. Specifications - 4 and 5 Ton MODELS I4H-A I4H-B I4H-C IH-A IH-B IH-C ELECTRICAL RATING-- HZ 2/20-2/ /20-2/ Operating Voltage Range COMPRESSOR Volts 2/20-2/ /20-2/ Rated Load Amps (2/20) 5./7.5.4/ / /4.3.3 Branch Circuit Selection Current Locked Rotor Amps ENERGY RECOVERY VENTILATOR Volts 2/20-- 2/20-- Full Load Amps (3-motors) FAN MOTOR ECM Horsepower /2 /2 Volts 2/20-- 2/20-- Full Load Amps CFM BLOWER MOTOR ECM Horsepower /2 3/4 Volts 2/20-- 2/20-- Full Load Amps rating points, will modulate based upon O.D. ambient. Complies with efficiency requirements of ASHRAE/IESNA Certified to ARI Standard for SPVU (Single Package Vertical Units). Intertek ETL Listed to Standard for Safety Heating and Cooling Equipment ANSI/UL 995/CSA 22.2 No , Third Edition. Commercial Product - Not intended for Residential application. Form No S3-2 Supersedes S3-32 Page 2 of

3 Capacity and Efficiency Ratings (Stage 2) Full Load Operation MODELS IH I3H I42H I4H IH Cooling, Full Load Capacity, 95-0/7 EER j Rated CFM Capacity and Efficiency Ratings (Stage ) Part Load Operation EER = Energy Efficiency Ratio - BTU/WATT efficiency IPLV = Integrated Part Load Value - BTU/WATT efficiency (combines full and part load performance) = Coefficient of Performance - BTU/WATT efficiency Indoor Blower Performance Model Motor will deliver consistent CFM through voltage supply range with no deterioration. Continous fan CFM is the total air being circulated during continuous fan mode. Will rated Full Load Airflow when operating with Heat Pump. Will occur automatically with a call for "W3" or "Emergency Heat" signal from thermostat (Heat Pump Operation is this condition). Unit Weights Rated ESP. Max. ESP k Continuous CFM Rated 2nd Stage CFM Rated st Stage CFM l 5-9 KW CFM m 3.5- KW CFM IH I3H I42H I4H IH Deduct 5# from all values for installed weight. 27, , , , IPLV (Integrated Full & Part Load) k 0-0/ Heating, Full Load Capacity 47/43-70 l Rated CFM Heating, Full Load Capacity 7/5-70 l Rated CFM 27, , , , , , , , , , , MODELS IH I3H I42H I4H IH Cooling, Part Load Capacity, 95-0/7 EER j Rated CFM Heating, Part Load Capacity 47/43-70 l Rated CFM Heating, Part Load Capacity 7/5-70 l Rated CFM MODELS NO VENT CRV ERV IH-A IH-B IH-C I3H-A I3H-B I3H-C I42H-A I42H-B I42H-C I4H-A 4 97 I4H-B 4 97 I4H-C 99 4 IH-A IH-B IH-C , , , , , , , , , , , , , , , MODELS NO VENT CRV ERV IHDA IHDB IHDC I3HDA I3HDB I3HDC I42HDA I42HDB I42HDC I4HDA I4HDB I4HDC IHDA IHDB IHDC Form No S3-2 Supersedes S3-32 Page 3 of

4 Factory Built-in Electric Heat Table Model Voltage Phase KW Amps A04 240/ ,,239 -A05 240/ ,05 2,799 -A 240/ , 25,59 -A5 240/ ,95 3,39 -A20 240/ ,2 5,95 -B0 240/ ,47 5,359 -B09 240/ ,77 23,03 -B2 240/ ,95,77 -B5 240/ ,95 3,39 -B 240/ ,434 4,07 -C ,47 5,359 -C ,77 23,03 -C ,95,77 -C ,95 3,39 -C ,434 4,07 NOTE: Not all KW's available in all models. See Minimum Circuit Ampacity and Maximum Overcurrent Protection table on following page. Optional Hot Water Coil Performance - Heating 0 F Water and 70 F Return Air Hot Water Coil Correction Factors Entering Air Temp (F) Entering Water Temperature (F) Form No S3-2 Supersedes S3-32 Page 4 of

5 Minimum Circuit Ampacity & Maximum Overcurrent Protection Std. & Dehum. MODEL IH-A0Z A05 A IH-B0Z B0 B09 IH-C0Z C0 C09 I3H-A0Z A05 A j A5 I3H-B0Z B0 B09 j B5 I3H-C0Z C0 C09 j C5 I42H-A0Z A05 A j A5 I42H-B0Z B0 B09 j B5 I42H-C0Z C0 C09 j C5 I4H-A0Z A04 A05 A j A5 j A20 I4H-B0Z B0 B09 j B5 j B I4H-C0Z C0 C09 j C5 j C IH-A0Z A05 A j A5 j A20 IH-B0Z B0 B09 j B5 j B IH-C0Z C0 C09 j C5 j C Rated Volts, Hertz & Phase 2/20-2/ /20-2/ /20-2/ /20-2/20-3 2/20-2/20-2/ No. Field Power Circuits or 2 or 2 or 2 or 2 or 2 or 2 or 2 or 2 or 2 or 2 or 2 or 2 or 2 or 2 Minimum Circuit Ampacity Single Circuit Maximum External Fuse or Ckt. Brkr. Field Power Wire Size These Minimum Circuit Ampacity values are to be used for sizing the field power conductors. Refer to the National Electric Code (latest revision), Article 3 for power conductor sizing. Caution: When more than one field power conductor circuit is run through one conduit, the conductors must be derated. Pay special attention to note of table 3 regarding Ampacity Adjustment Factors when more than three (3) current carrying conductors are in a raceway. Ground Wire Maximum size of the time delay fuse or HVAC type circuit breaker for protection of field wiring conductors. Based on 75 C copper wire. All wiring must conform to the National Electrical Code and all local codes. Maximum KW that can operate with the heat pump is KW for -Phase and 9KW for 3-Phase. Represents Electric Heat only. Electric Control Circuit will lock-out Heat Pump Operation Minimum Circuit Ampacity Maximum External Fuse or Ckt. Breaker Multiple Circuit Field Power Wire Size Ground Wire Size Ckt. A Ckt. B Ckt. A Ckt. B Ckt. A Ckt. B Ckt. A Ckt. B Form No S3-2 Supersedes S3-32 Page 5 of

6 Cooling Full Load Application Data Model IH I3H I42H I4H IH D.B. / W.B. k 75/2 0/7 5/72 75/2 0/7 5/72 75/2 0/7 5/72 75/2 0/7 5/72 75/2 0/7 5/72 COOLING CAPACITY F 5 F 70 F 75 F 0 F 5 F 90 F 95 F 0 F 5 F F 5 F 20 F 25 F,74 23,57 33,4 23,9 35,990 23,0 39,03,2 42,49,7,32,57 4,5 35,042 5,03 35,75 54,35 35,505 5,43 39, 5,93 3,4 5,44 3,5,34,49,2 44,33 72,02 44,000,05 23,29 32,75 23,4 35,372 23,272 3, 29,72 4,4,250 44,90 29,975,740 34, 49,725 35,23 53,3 34,92 50, 3, 55,497 3,29 54,927 37,39 5, 44,379 4,75 43,700 70,20 43,27 29,349 22,74 3,3 22,994 34,754 22,73 37,3 29,33 40,50 29,73 44,0 29,34 44, 34,33 4,43 34,79,3 34,33 49,0 3, 54,0 37,24 53,40 37, 57,34 43,9 3,03 43,03,375 42,533 2,4 22,3 3,050 22,500 34,3 22,204 3,9 2,93 39,5 29,75 43,4 2,792 43,492 33,975 47,50 34,200 5,3 33,75 47,49 37,39,4 37,029 5,9 3,44 55,3 42,40,0 42,425,550 4,00 27,934 2,94,200 22,000 33,5 2,7 35, 2,54 3,500 2,0 42,727 2,200 42,3 33,20 44,500 32,75 50,37 33, 4,57 3, 5,000 35,950 50,39 35,0 54,33 42,070 59,3 4,7 4,724 4,07 27,22 2,575 29,3 2,50 32,900 2,37 34,75 2,4 37,59 2,03 42,00 27, 4,244 33,24 43,23 32,5 49,37 32,5,5 35,97 49,54 35,355 4,50 35,29,795 4, 5,225 4,50 2,99 40,333 2,59 2,7 2,3 2,09 32,22 20,3 33,905 27,75 3,5 27,53 4,275 27,0 40,20 32,909 43,2 32,44 4,3 3,99 43,54 35,2 4,4 35,2 47,33 34, 5,27 40,53 5,3 40,53,073 39,0 25,2 20,799 27,00 20,5 3,4 20,09 33,054 27,35 35,0 27,025 40,54 2,424 3,99 32,553 42,000 32,25 47,3 3,4 42,2 34,55 47,000 34,50, 33,774 49,7 39,72 55,000 39,75 59,24 3,7 24,97 20,59 2,900 20,325,39 9,73 3,00 2,53 34,250 2,500 39,0 25,9 3,00 32,9 40,933 3,775 4,23 3,0 40,9 33,5,29 33,953 44,075 33,094 4,044 39,025 53,4 39,3 57,205 3,4 24,40 20,393 2,000 20,25 29,4 9,7,547 2,32 32,900 25,975 37,473 25,39 37,05 3,43 39,7 3,424,40,72 39,299 33, 43,437 33,25 42,339 32, 4,329 3,27 5,20 3,397 55,3 37,42 23,5 20,9 25,0 9,925 2,59 9,42 29,293 25,79 3,550 25,0 35,935 24,4 3,025 3,4 3,00 3,074 44,94,33 37,7 32,4 4,5 32,559 40,3 3,735 44,3 37,550 49,32 37,57 53,20 3,705 22,49 9,9 24,200 9,725 27,54 9,27 2,040 25,257,200 24,925 34,39 24,37 35,035 3,33 37,734,723 42,979,040 3,07 3,77 39,75 3,2 3, 3,05 42,9 3,3 47, 3,9 5,077 35,95 2,33 9,75 23,0 9,5 2,539 9,09 2,77 24,725 2,50 24,400 32, 23,5 34,0,77 3,7,373 4,74 29,9 34,44 3,07 3,093 3,5 37,,37 4,2 3,07,59 3,79 49,035 35,24 20,79 9,53 22,400 9,325 25,54,9 25,533 24,93 27,500 23,75 3,323 23,344 33,054,423 35,,022 40,549 29,355 32,,3 3,32,47 35,394 29,97 39,47 35,339 43,23 35,440 4,992 34,544 Cooling Part Load Application Data Model IH I3H I42H I4H IH D.B. / W.B. k 75/2 0/7 5/72 75/2 0/7 5/72 75/2 0/7 5/72 75/2 0/7 5/72 75/2 0/7 5/72 Form No S3-2 Supersedes S3-32 Page of COOLING CAPACITY F 5 F 70 F 75 F 0 F 5 F 90 F 95 F 0 F 5 F F 5 F 20 F 25 F 24,,25 2,025,000 27,27 7,242 29, 23,790 32,000 23,43 33,542 22,4,04 25,9 32,43 24,3 33, 23,757 20, 5,333 23,094 5,44 20, 4,970 42,05 3,549 47,39 3,23 5,94,902 23,33 7,90 25,250 7,700 2,729 7,05 2,3 23,242 3,000 22,975 32,24 22,4 29,3 24,7 32,03 24,475 33,7 23,57 22,02,54 24,43,3 22,342,99 4,472,90,,50 50,334,29 22,5 7,5 24,475 7,400 2,90,9 27,720 22,94,000 22,4 32, 2,05 29,9 24,32 3,594 24,3 33,75 23,399 23,2 7,75 25,7 7,3 24,57 7,427 40,39,232 44,40,03 4,72 29,90 2, 7,24 23,700 7,0 25,,3 2,75 22,4 29,000 22,000 3,3 2,43 2,75 23,95 3,75 23,00 33,742 23,220 24,3,97 27,25,75 2,,5 3,07 29,574 42,925 29,425 47,2 29,03 2,20, 22,00,75 25,3,497 25,79 2,599 27,0 2,75,70 2,22 2,332 23,555 32,000 23,0 33,79 23,040 25,743 20,3 3,000 25,250 29,044 9,4 37,474 2,9 4,000 2,500,55 2,477 Below 50 F, unit requires a factory or field installed low ambient control. Return air temp. F Rated CFM. 20,372,59 22,025,375 24,575,3 24,33 2,05 2,0 20, 29,953 20,70 27,99 23,5 3,5 23,23 33,9 22, 2,94 2,395 37,344 2,494 3,27 2,3 3,42 2,25 39,59 27, 43,90 27,70 9,25,72 2,375,200 24,037,24 23,7 20,503 2,000 20,53 29,235 20,439 27, 22,747 29,99 22,7 33,73 22,2 2,4 22, 3,5 22, 33, 22,34 34,09 27,599 3,4 27,5 42, 27,24,77 5,25 20,0 5,900 23,49 5,93 22,909 9,955 25,000 20,050 2,57 20,09 27,032 22,344 29,500 22,0 33,50 22,503 29,405 23,20 32,500 23,50 35,7 23,570 33,47 2,94 37,000 2,975 40,95 2,5,22 5, 9,75 5,0 22,7 5,37 22,233 9,743 24,23 9,3 27,7 9,5 2,09 22,055 2,473 22, 32,479 22,23 2,404 23,5 3,394 23,54 34,9 23,29 32,47 2,55 35,90 2,9 39,492 2, 7,54 5,227 9,50 5,0 2,44 5,33 2,557 9,532 23,5 9,25 2,35 9,72 25,50 2,77 27,44 2,7 3,7 2,923 27,403 23,22,2 23,24 33,32 22,9 3,497 2,2 34,3 2,23 3,29 25,954,4 4,929,425 5,000 2,07 5,03 20, 9,32 22,7 9,43 25,993 9,9 24,209 2,479 2,49 2,5,3 2,33 2,402 22,90 29, 22,937 32,095 22,7,50 25,74 33,79 25,90 37,0 25,2,29 4, 7,700 4,700 20,90 4,735 20,20 9,9 22,050 9,200 25, 9,24 23,2 2,9 25,392 2,292 2,94 2,342 25,40 22,4 2,075 22,33,79 22,37 29,5 25,5 32,25 25,550 35,3 25,250 5,555 4,332,975 4,400 9,33 4,434 9,5,9 2,33,9 24,3 9,033 22,327 20,903 24,35 2,002 27,793 2,0 24,400 22,0 2,99 22,32 29,2 22,0 2, 25,2 3,53 25,94 34, 24,97 4,9 4,033,250 4,0,53 4,33,54, 20,575,775 23,470,9 2,3 20,5 23,33 20,73 2,22 20,72 23,399 2,997 25,3 22,024 2,4 2,75 27,539 24,0,43 24,3 33,477 24,5

7 Heating Full Load Application Data Model Indoor F IH I3H I42H I4H IH j 70 F, , , , , , , , , , , , , , , , , , , , , , , , , , , , , , F DB indoor return air at rated CFM includes defrost operation below. 2, , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , Heating Part Load Application Data Model Indoor F IH I3H I42H I4H IH j 70 F, ,9 0.5, , , , ,33 9., , , ,50.79, , , , , , , , , , , , , , , , , , , F DB indoor return air at rated CFM includes defrost operation below. 5, , , , , ,400 3., , , , , , , , , , , , ,0 2, , , , , , , , , , , , , , , , , Form No S3-2 Supersedes S3-32 Page 7 of

8 Performance and Application Data Energy Recovery Vent Option "R" Ambient O.D. VENTILATION RATE 0 CFM 5% EFFICIENCY SUMMER COOLING PERFORMANCE (INDOOR DESIGN CONDITIONS 75 DB/2 WB) VENTILATION RATE 375 CFM % EFFICIENCY VENTILATION RATE 0 CFM 7% EFFICIENCY DB/WB F VLT VLS VLL HRT HRS HRL VLT VLS VLL HRT HRS HRL VLT VLS VLL HRT HRS HRL Form No S3-2 Supersedes S3-32 Page of Ambient O.D. WINTER HEATING PERFORMANCE (INDOOR DESIGN CONDITIONS 70 F DB) VENTILATION RATE 0 CFM 0% EFFICIENCY 375 CFM % EFFICIENCY 0 CFM 2% EFFICIENCY DB/ F WVL WHR WVL WHR WVL WHR NOTE: Sensible performance only is shown for winter application. LEGEND: VLT = Ventilation Load - Total VLS = Ventilation Load - Sensible VLL = Ventilation Load - Latent HRT = Heat Recovery - Total HRS = Heat Recovery - Sensible HRL = Heat Recovery - Latent WVL = Winter Ventilation Load WHR = Winter Heat Recovery

9 I-TEC Accessory Model Numbers Wall Sleeves (Required Option Select One) Model #: Description: IWS-A Wall Sleeve adjustable 5.5 to.5" total depth of wall system IWS-B Wall Sleeve adjustable.0 to 3.5" total depth of wall system IWS-C Wall Sleeve adjustable 3.0 to 23.5" total depth of wall system Outdoor Louver Grilles (Required Option Select One) Model #: ILG- ILG-20 ILG- Duct-Free Plenum Boxes Model #: IPBDF2-X IPBDF2- IPBDF2-4 IPBDF-X IPBDF- IPBDF-4 Description: Clear anodized aluminum Medium bronze anodized aluminum Dark bronze anodized aluminum I-TEC Accessories Optional per Job Requirement Description: Duct-Free Plenum Boxes with Hot Water Coil Model #: IPBDF2HW-X IPBDF2HW- IPBDF2HW-4 2" high with front and side 4-way deflection grilles, beige paint 2" high with front and side 4-way deflection grilles, white paint 2" high with front and side 4-way deflection grilles, gray paint " high with front and side 4-way deflection grilles, beige paint " high with front and side 4-way deflection grilles, white paint " high with front and side 4-way deflection grilles, gray paint Description: NOTE: No water control valves included. Field-Installed. Hot Water Coil with Duct Connection Model #: IHWC 2" high with front and side 4-way deflection grilles, beige paint, w/hot water coil 2" high with front and side 4-way deflection grilles, white paint, w/hot water coil 2" high with front and side 4-way deflection grilles, gray paint, w/hot water coil Description: Hot water coil assembly, mounts on top of I-TEC unit, " x " duct flange NOTE: No water control valves included. Field-Installed. NOTE: Order appropriate Cabinet Extension (Model ICX2-*) to enclose hot water coil assembly, valves, piping and ductwork. Cabinet Extensions Model #: Description: ICX2-X 2" extension for ceilings up to '2", beige paint ICX2-2" extension for ceilings up to '2", white paint ICX2-4 2" extension for ceilings up to '2", gray paint NOTE : Use of Riser Platforms will increase maximum ceiling height by riser height. NOTE 2: Cabinet Extensions can be used with ducted systems to enclose ductwork or piping, and can also be used with Duct-Free Plenum Boxes to enclose to ceiling if desired. Extensions can be trimmed to height as needed. Riser Platforms Model #: Description: IRP-3-X Riser platform 3" with trim kit, beige paint IRP-3- Riser platform 3" with trim kit, white paint IRP-3-4 Riser platform 3" with trim kit, gray paint IRP--X Riser platform " with trim kit, beige paint IRP-- Riser platform " with trim kit, white paint IRP--4 Riser platform " with trim kit, gray paint NOTE: Use of Riser Platforms will increase maximum ceiling height by riser height. Form No S3-2 Supersedes S3-32 Page 9 of

10 Top View 3 " " 24" 2 4 " Front View (2) 2"x24"x" Filters Return Air Control Panel (2) Washable Vent Intake Air Filters (2) 2" x 20" Air Filters Vent Exhaust " " Total Width " With Sides Removed 20" 20" x 24" Supply Frame " 3 3 " Total Depth Low Voltage 2" High Voltage Entrance 7 " Entrance Electric Heat Wire Channel (4) Lift-Off Hinges Locking Door Latch Electrical Disconnect 94" Total Height 5" " Upper Section Locking Door Latch 4 3 " 5 5 " 22 4 " Lower Section Front Forklift Holes (Remove Front Trim) Side Forklift Holes (Remove Sides) Right Side View " With Doors and Sides Removed Unit Specification Sheet (2) Return Openings Outer Sleeve Supply Air Back View Return Air Return Air Inner Sleeve Outer Sleeve Inner Sleeve 2 " 7 (2) Side Handles 24 2 " (2) Unit Drains (2) Opt. Unit Drain Entrances " " " 3 3 " MIS-297 A Form No S3-2 Supersedes S3-32 Page of

11 Duct Optional Wall Section View Ceiling Optional Trim or Supply Duct Box Outside Wall Telescoping Wall Sleeve** Sleeve Mounting Hole Locations Centered on Opening Outside Wall Centered 20" 42-3/4" Min. 43-/4" Max. Grille Centered 4" Min. 4-/2" Max. 20" 3 49 " Unit Floor 3" Min. 34" Max. * 5 " 3" Min. 34" Max. * 20" 43 7 " 20" 4 " Room Floor Level Right Side View Front (Wall Only) View * Higher Sill Heights Acheivable With Base Kit. ** Separate telescoping sleeves available for different wall thicknesses. MIS-29 A Form No S3-2 Supersedes S3-32 Page of

12 ROUTE LOW VOLTAGE UNIT POWER THROUGH BOX IN CONDUIT IPBDF AND IPBDF2 DUCT-FREE PLENUM BOX DIMENSIONS A ROUTE HIGH VOLTAGE UNIT POWER THROUGH BOX IN CONDUIT B 94" 7' - " DIMENSIONAL CHART MODEL NO. DIM. A DIM. B IPBDF " 2" ('-") IPBDF2 2" " ('-") MIS-57 Form No S3-2 Supersedes S3-32 Page 2 of

13 TOP VIEW VALVE WIRING ENTRANCE 4 /2" 2" 2" 7 3/4" 3/" IPBDF2HW DUCT-FREE HOT WATER COIL DIMENSIONS Ø7/" O.D. WATER CONNECTIONS. NOT DESIGNATED AS "IN" OR "OUT". CAN BE PIPED AS NEEDED FOR EASE OF VALVE INSTALLATION AND SUPPLY/RETURN CONNECTIONS. ROUTE LOW VOLTAGE UNIT POWER THROUGH BOX IN CONDUIT 2" 2" ROUTE HIGH VOLTAGE UNIT POWER THROUGH BOX IN CONDUIT HIGH VOLTAGE POWER ENTRANCE " ' - " 94" 7' - " MIS-59 Form No S3-2 Supersedes S3-32 Page 3 of

14 TOP VIEW 9 7/" 29 7/" /4" IHWC DUCTED HOT WATER COIL DIMENSIONS 23 7/" SUPPLY OPENING 9 7/" 24 3/4" 9 3/4" 2" LOW VOLTAGE ENTRANCE 40 7/" Ø7/" O.D. WATER CONNECTIONS. NOT DESIGNATED AS "IN" OR "OUT". CAN BE PIPED AS NEEDED FOR EASE OF VALVE INSTALLATION AND SUPPLY/RETURN CONNECTIONS. " ROUTE HIGH VOLTAGE UNIT POWER THROUGH BOX IN CONDUIT 2.5" HIGH VOLTAGE POWER ENTRANCE 5" ' - 9" 94" 7' - " MIS-5 Form No S3-2 Supersedes S3-32 Page 4 of

15 This page intentionally left blank. Form No S3-2 Supersedes S3-32 Page 5 of

16 I-TEC 2-Stage Air Source Heat Pumps Model Number Nomenclature I 3 H D A 0Z R P 4 X X 2 Model Series Controls: X = 24v terminal block Only w/o CompleteStat = CompleteStat THO (Temp, Humidity and Occupancy) 2 = CompleteStat THO w/co2 3 = CompleteStat THO w/ Ethernet 4 = CompleteStat THO w/co2 and Ethernet Note: CompleteStat must be field installed and wired. Nominal Capacity: All units have 24V terminal block. See Selection Guide. =,000 3 = 3, = 42,000 Coil Treatment: 4 = 4,000 X = Std. Hydrophilic Fin Evap. & Uncoated Alum. Cond. Coil =,000 = Phenolic Coated ID coil 2 = Phenolic Coated OD coil System Type: 3 = Phenolic Coated ID and OD coil H = Heat Pump X = Reserved Revision Level: Color: (-) = Standard (Non-Dehum) X = Beige, Painted Steel D = Dehumidification = White, Painted Steel 4 = Gray, Painted Steel Electrical Rating: A = 2/20, - B = 2/20, -3 C = 4--3 Filter: Electric Heat: P = 2 inch pleated MERV 0Z = No heat w/ breaker M = 2 inch pleated MERV 04 = 4KW -Phase N = 2 inch pleated MERV 3 05 = 5KW -Phase 0 = KW 3-Phase Vent Option: 09 = 9KW 3-Phase B = Blank Off Plate = KW -Phase M = Multi-Speed CRV 5 = 5KW & 3-Phase R = ERV = KW 3-Phase 20 = 20KW -Phase CompleteStat Selection Guide Vent Type None CRV ERV Type of Vent Control BACnet j Communication Ethernet k Connection Control Code Description CompleteStat Part Number N/A Yes No CompleteStat THO (Temp, Humidity & Occupancy) CS9B-THO N/A Yes Yes 3 CompleteStat THO w/ethernet CS9BE-THO On/Off Yes No CompleteStat THO (Temp, Humidity & Occupancy) CS9B-THO Demand l Yes No 2 CompleteStat THO w/co2 CS9B-THOC On/Off Yes Yes 3 CompleteStat THO w/ethernet CS9BE-THO Demand l Yes Yes 4 CompleteStat THO w/co2 & Ethernet CS9BE-THOC On/Off Yes No CompleteStat THO (Temp, Humidity & Occupancy) CS9B-THO Demand l Yes No 2 CompleteStat THO w/co2 CS9B-THOC On/Off Yes Yes 3 CompleteStat THO w/ethernet CS9BE-THO Demand l Yes Yes 4 CompleteStat THO w/co2 & Ethernet CS9BE-THOC BACnet is standard - all versions, shielded twisted pair. These models also have CAT 5 port for ease of networking in addition to twisted pair terminals. Demand control for ventilation is ON/OFF based on CO2 set-point. If modulating mode for ERV is required, use THO controller plus CO2 controller with modulating output. Form No S3-2 Supersedes S3-32 Page of Bard Manufacturing Company, Inc. Bryan, Ohio Due to our continuous product improvement policy, all specifications subject to change without notice. Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. Form No. S3 August, 202 Supersedes: S3-32

THE WALL-MOUNT QUIET-CLIMATE HEAT PUMPS

THE WALL-MOUNT QUIET-CLIMATE HEAT PUMPS THE WALL-MOUNT QUIET-CLIMATE HEAT PUMPS Models: SH21, SH311, SH31, SH431, SH41, SH High Efficiency Heating Capacities: 21, to 55, Ultra Low Sound Level Cooling Capacities: 23, to 55, Refrigerant 22 The

More information

THE WALL-MOUNT STEP CAPACITY HEAT PUMPS Integrated Part Load Value (IPLV) Efficiency Up To 15.0 BTU/WATT

THE WALL-MOUNT STEP CAPACITY HEAT PUMPS Integrated Part Load Value (IPLV) Efficiency Up To 15.0 BTU/WATT THE WALL-MOUNT STEP CAPACITY HEAT PUMPS Integrated Part Load Value (IPLV) Efficiency Up To 5.0 BTU/WATT Green Refrigerant R-4A Models: C24H to C0H Up to.0 EER Cooling Capacities: 22,200 to 55,0 BTUH Heating

More information

Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed.

Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed. THE WALL-MOUNT AIR CONDITIONERS -. EER, (HZ) Models WAA to W72AA Right-Side Control Panel Models WLA to W72LA Left-Side Control Panel. to Ton (7, to 7, Btuh) Green Refrigerant R-4A The Bard Wall-Mount

More information

The Wall-Mount Step Capacity Gas/Electric - WG*S Series Integrated Part Load Value (IPLV) Efficiency Up to 15.6 BTU/WATT.

The Wall-Mount Step Capacity Gas/Electric - WG*S Series Integrated Part Load Value (IPLV) Efficiency Up to 15.6 BTU/WATT. The Wall-Mount Step Capacity Gas/Electric - WG*S Series Integrated Part Load Value (IPLV) Efficiency Up to 15.6 BTU/WATT WG3S2, WG4S2, WG5S2 6HZ 24, to 56,5 BTUH Cooling Capacity 37, to 12,5 BTUH Heating

More information

Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed.

Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed. THE WALL-MOUNT AIR CONDITIONER -. EER, (HZ) Models WAA to W7AA Right-ide Control Panel Models WLA to W7LA Left-ide Control Panel. to Ton (7, to 7, Btuh) The Bard Wall-Mount Air Conditioner is a self contained

More information

Introduction. Duct-Free Plenum Boxes. I-TEC Accessories Plenum Boxes, Risers, Trim Kits, and Wall Curbs

Introduction. Duct-Free Plenum Boxes. I-TEC Accessories Plenum Boxes, Risers, Trim Kits, and Wall Curbs I-TEC Accessories Plenum Boxes, Risers, Trim Kits, and Wall Curbs Introduction When installing the I-TEC in a classroom or other occupied environment, sound and appearance is very important to a customer.

More information

QTEC SERIES PACKAGED AIR CONDITIONER Models: Q24A2 Q30A2 Q36A2 Q42A2 Q48A2 Q60A2 REPLACEMENT PARTS MANUAL. Contents. General Notes.

QTEC SERIES PACKAGED AIR CONDITIONER Models: Q24A2 Q30A2 Q36A2 Q42A2 Q48A2 Q60A2 REPLACEMENT PARTS MANUAL. Contents. General Notes. REPLACEMENT PARTS MANUAL General Notes Revised and/or additional pages may be issued from time to time. A complete and current manual consists of pages shown in the following contents section. QTEC SERIES

More information

THE WALL-MOUNT AIR CONDITIONERS - WA (60HZ)

THE WALL-MOUNT AIR CONDITIONERS - WA (60HZ) THE WLL-MOUNT IR CONDITIONERS - W (HZ) W-SERIES Hz. to Ton (,3 to 7, Btuh) Right Side Control Panel Refrigerant The Bard Wall-Mount ir Conditioner is a self contained energy efficient system, which is

More information

GREEN REFRIGERANT R-410A

GREEN REFRIGERANT R-410A THE WALL-MOUNT STEP CAPACITY AIR CONDITIONERS Integrated Part Load Value (IPLV) Efficiency Up To. BTU/WATT WAS WAS Right Side Control Panel WLS WLS Left Side Control Panel to Ton (,4 to, Btuh) Hz GREEN

More information

REPLACEMENT PARTS MANUAL

REPLACEMENT PARTS MANUAL REPLACEMENT PARTS MANUAL W4H-A W4H-B W4H-C WALL MOUNTED PACKAGED HEAT PUMPS W4HDA W4HDB W4HDC W4H-A W4H-B W4H-C Models: W4HDA W4HDB W4HDC W0H-A W0H-B W0H-C W0HDA W0HDB W0HDC General Notes Revised and/or

More information

THE WALL-MOUNT AIR CONDITIONERS - WA (60HZ)

THE WALL-MOUNT AIR CONDITIONERS - WA (60HZ) THE WLL-MOUNT IR CONDITIONERS - W (HZ) W-SERIES Refrigerant 22 Hz. to Ton (, to 7, Btuh) Right Side Control Panel The Bard Wall-Mount ir Conditioner is a self contained energy efficient system, which is

More information

M-SERIES MHP4 MODEL NUMBER GUIDE 3 M HP F P 1 ELECTRIC HEAT PUMP PACKAGED UNITS REVISION CODE

M-SERIES MHP4 MODEL NUMBER GUIDE 3 M HP F P 1 ELECTRIC HEAT PUMP PACKAGED UNITS REVISION CODE ELECTRIC HEAT PUMP PACKAGED UNITS MHP4 FORM NO. MHP4-100 (10/2018) MODEL NUMBER GUIDE 3 M HP 4 11 18 1 F P 1 FACTORY INSTALLED ELECTRIC HEAT 3= 3 KW 5 = 5 KW 7 = 7 KW 10 = 10 KW M = MAGIC-PAK HP = HEAT

More information

THE WALL-MOUNT GAS/ELECTRIC - WG-SERIES

THE WALL-MOUNT GAS/ELECTRIC - WG-SERIES THE WALL-MOUNT GASELECTRIC - WG-SERIES WG - SERIES to Ton 3, to 6, BTUH Capacity 1, to 1, BTUH Heating Input 6HZ The Bard Wall-Mount Electric Air Conditioner with gas fired heating is a self contained

More information

REPLACEMENT PARTS MANUAL

REPLACEMENT PARTS MANUAL REPLACEMENT PARTS MANUAL WAA-C Wall-Mount Air Conditioner with 0- VFD-High Resistance Ground Kit NOTE: For installation guidance for the 0- kit, contact Bard Technical Services at () -0. Contents Description

More information

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: 036-21323-001-B-0202 GENERAL SPECIFICATIONS OUTDOOR UNIT: Two independent refrigerant circuits Inherently protected fan motors Two independent scroll compressors V-Coil Design Exterior service port connections

More information

REPLACEMENT PARTS MANUAL

REPLACEMENT PARTS MANUAL REPLACEMENT PARTS MANUAL W30H-A W30H-B W30H-C WALL MOUNTED PACKAGED HEAT PUMP W30HDA W30HDB W30HDC Models: W36H-A W36H-B W36H-C W36HDA W36HDB W36HDC General Notes Revised and/or additional pages may be

More information

V High Efficiency Series

V High Efficiency Series UNIT DISCONNECT(S) BEHIND THIS PANAL Commercial HVAC V High Efficiency Series Wallmount Air Conditioners PERFORMANCE: Efficiency rating of 9.0/9.5 EER Electric heat available from 5 kw to 18 kw Designed

More information

REPLACEMENT PARTS MANUAL

REPLACEMENT PARTS MANUAL REPLACEMENT PARTS MANUAL WALL MOUNTED PACKAGED HEAT PUMP Models: W18H-A W4H-A W4H-B W4H-C W4HDA W4HDB W4HDC General Notes Revised and/or additional pages may be issued from time to time. A complete and

More information

GREEN REFRIGERANT R-410A

GREEN REFRIGERANT R-410A WLL-MOUNT -TON IR CONDITIONERS J7 - Right Side Control Panel J7L - Left Side Control Panel, 9.5 EER Hz Solair Wall-Mount ir Conditioner is a self contained energy efficient system, which is designed to

More information

GPC14H. 2- to 5-Ton Packaged Air Conditioner 14 SEER. Cooling Capacity: 24,000-57,500 BTU/H

GPC14H. 2- to 5-Ton Packaged Air Conditioner 14 SEER. Cooling Capacity: 24,000-57,500 BTU/H H Cooling Capacity: 24,000-57,500 BTU/H 2- to 5-Ton Packaged Air Conditioner 14 SEER Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data... 4 Airflow Data... 16 Heater Kit Specifications...

More information

Product Data. Features/Benefits. Omnizone 50XCA06-14 Air-Cooled Indoor Self-Contained Systems with Puron Refrigerant (R-410A) 5 to 12 Nominal Tons

Product Data. Features/Benefits. Omnizone 50XCA06-14 Air-Cooled Indoor Self-Contained Systems with Puron Refrigerant (R-410A) 5 to 12 Nominal Tons Product Data Omnizone 50XCA06-14 Air-Cooled Indoor Self-Contained Systems with Puron Refrigerant (R-410A) 5 to 1 Nominal Tons The 50XCA single-package cooling units with integral air-cooled condensers

More information

i Series Model SV Water Source Heat Pump 1/2 to 6 Ton

i Series Model SV Water Source Heat Pump 1/2 to 6 Ton i Series Model SV Water Source Heat Pump 1/2 to 6 Ton Engineering Submittal Sheet Overview and Certifications Standard Features, Factory Installed Options, and Field Installed Accessories Standard Features

More information

REPLACEMENT PARTS MANUAL

REPLACEMENT PARTS MANUAL REPLACEMENT PARTS MANUAL WHA-A WHA-B WHA-C WALL-MUNTED PACKAGED HEAT PUMP WHADA WHADB WHADC WHA-A WHA-B WHA-C Models: WHADA WHADB WHADC W0HA-A W0HA-B W0HA-C W0HADA W0HADB W0HADC Contents Description Page

More information

TECHNICAL GUIDE GENERAL HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS AND WATER COOLED AIR CONDITIONERS

TECHNICAL GUIDE GENERAL HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS AND WATER COOLED AIR CONDITIONERS TECHNICAL GUIDE HIGH-EFFICIENCY WATER SOURCE H PUMPS AND WATER COOLED AIR CONDITIONERS HORIZONTAL & VERTICAL MODELS 1/2-5 TONS GENERAL All Models 1/2-5 tons ship as factory-charged packages. Horizontal

More information

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINTS

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINTS 50FN-1SB 50FNX,FNY078,088,104 SINGLE-PACKAGE COOLING UNITS CONSTANT/VARIABLE AIR VOLUME PRODUCT INTEGRATED CONTROLS CARRIER COMFORT NETWORK COMPATIBLE WITH INTEGRAL ECONOMIZER AND HIGH-CAPACITY MODULATING

More information

A I R H A N D L E R S CB26UH-R. MERIT Series R-22 - Upflow / Horizontal P R O D U C T S P E C I F I C AT I O N S

A I R H A N D L E R S CB26UH-R. MERIT Series R-22 - Upflow / Horizontal P R O D U C T S P E C I F I C AT I O N S P R O D U C T S P E C I F I C AT I O N S A I R H A N D L E R S CB6UH-R MERIT Series R- - Upflow / Horizontal Bulletin No. 1067 April 01 Supersedes January 01 Nominal Capacity - 1.5 to 5 Tons Optional Electric

More information

CHP

CHP Packaged Unit Heat Pump CHP16-024-030-036-048-060 2-5 Ton Cooling 23,000-57,500 Btuh Heating 12,800-85,300 Btuh (5-25 kw) Optional Electric Heating FEATURES Designed for outdoor rooftop or ground level

More information

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11. TECHNICAL SPECIFICATIONS Q6SP Series Rev A 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.0 EER Commercial Systems Meet or Exceed ASHRAE 90.1-2010 These 7½ and 10 ton units are designed

More information

Product Data. Features/Benefits. OMNIZONE 50XCR06-24 Remote Air-Cooled Indoor Self-Contained Systems with PURON Refrigerant (R-410A)

Product Data. Features/Benefits. OMNIZONE 50XCR06-24 Remote Air-Cooled Indoor Self-Contained Systems with PURON Refrigerant (R-410A) Product Data OMNIZONE 50XCR06-24 Remote Air-Cooled Indoor Self-Contained Systems with PURON Refrigerant (R-410A) 5 to 20 Nominal Tons The 50XCR single-package remote aircooled units offer: Compact, durable,

More information

REPLACEMENT PARTS MANUAL

REPLACEMENT PARTS MANUAL REPLACEMENT PARTS MANUAL PACKAGE HEAT PUMP Models: PH242-A PH363-A PH302-A PH363-B General Notes Revised and/or additional pages may be issued from time to time. A complete and current manual consists

More information

REPLACEMENT PARTS MANUAL

REPLACEMENT PARTS MANUAL REPLACEMENT PARTS MANUAL WALL MOUNTED PACKAGED AIR CONDITIONER Models: W1AA-A WAA-A WAA-B WAA-C WAA-D WAA-F General Notes Revised and/or additional pages may be issued from time to time. A complete and

More information

REPLACEMENT PARTS MANUAL

REPLACEMENT PARTS MANUAL REPLACEMENT PARTS MANUAL WALL MOUNTED PACKAGED AIR CONDITIONER Models: WAA-A WAA-A WAA-B WAA-C WAA-D WAA-F General Notes Revised and/or additional pages may be issued from time to time. A complete and

More information

D M S 760 C01 A A 1 1

D M S 760 C01 A A 1 1 CONTENTS Description Features Options Available Selection Method Product Data Cooling Performance Data (85 F Ambient Cooling Performance Data (95 F Ambient) Cooling Performance Data (105 F Ambient)..............................

More information

PGC COMMERCIAL PACKAGED GAS/ELECTRIC

PGC COMMERCIAL PACKAGED GAS/ELECTRIC PGC COMMERCIAL PACKAGED GAS/ELECTRIC PRODUCT SPECIFICATIONS 7½ TO 10 TON 10.3 EER COOLING CAPACITY 86,000-116,000 BTU/H HEATING CAPACITY 193,000-225,000 BTU/H The Goodman PGC Commercial Packaged Gas/Electric

More information

Contents. Control Panel. Control Panel. Blower Housing. Bard Manufacturing Company, Inc. Bryan, Ohio 43506

Contents. Control Panel. Control Panel. Blower Housing. Bard Manufacturing Company, Inc. Bryan, Ohio 43506 REPLACEMENT PARTS MANUAL WALL MOUNTED PACKAGE HEAT PUMPS Models: W4H W4HD W4H W4HD W0H W0HD General Notes Revised and/or additional pages may be issued from time to time. A complete and current manual

More information

Tons BTU/h S.E.E.R* E.E.R** HSPF

Tons BTU/h S.E.E.R* E.E.R** HSPF SOUND REFRIGERANT ENVIRONMENTALLY PHD3 Product Specifications 13 SEER, R -410A PACKAGE HEAT PUMP, 2½ to 5 TONS 3 -Phase, 208/230-3 -60 and 460-3 -60 REFRIGERATION CIRCUIT R--410A refrigerant Copper tube/aluminum

More information

Product Data. Features/Benefits 50JS SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS)

Product Data. Features/Benefits 50JS SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS) SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS) Product Data UNIT (50 Hz) Single-packaged Heat Pump for Residential and Light Commercial applications. Features/Benefits One-piece

More information

i Series Model SV Water Source Heat Pump 1/2 to 6 Ton

i Series Model SV Water Source Heat Pump 1/2 to 6 Ton i Series Model SV Water Source Heat Pump 1/2 to 6 Ton Engineering Submittal Sheet Overview and Certifications Standard Features, Factory Installed Options, and Field Installed Accessories Standard Features

More information

REPLACEMENT PARTS MANUAL

REPLACEMENT PARTS MANUAL REPLACEMENT PARTS MANUAL WALL MOUNTED PACKAGED AIR CONDITIONER Models: WLB-A WLB-A WLB-B WLB-F General Notes Revised and/or additional pages may be issued from time to time. A complete and current manual

More information

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO technical sales guide - 60Hz Taurus R Ducted Split Units UPTO HIGH AMBIENT OPERATION 52 O C Page CONTENTS Nomenclature.. 2 Description. 3 Features.. 3 Product Data. 4 Condensing Unit Cooling Performance

More information

TSTAT0201CW (Sold Separately) Qualifying models only. Max. Fuse or Breaker

TSTAT0201CW (Sold Separately) Qualifying models only. Max. Fuse or Breaker HVA9 Product Specifications HIGH EFFICIENCY UP TO 19 SEER VARIABLE SPEED AIR CONDITIONER WITH OBSERVER COMMUNICATING CONTROL SYSTEM 2 THRU 5 TONS SPLIT SYSTEM 208 230 Volt, 1 phase, 60 Hz REFRIGERATION

More information

PHR5. Product Specifications

PHR5. Product Specifications PHR5 Product Specifications UP to 15.5 SEER, UP to 12.5 EER, PACKAGE HEAT PUMP UNITS, 2 5 TONS 208/230 Volt, 1 phase, 60 Hz 208/230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally balanced R

More information

Si Series Model CE Residential Geothermal Heat Pump

Si Series Model CE Residential Geothermal Heat Pump Si Series Model CE Engineering Submittal Sheet Overview and Certifications Standard Features, Factory Installed Options, and Field Installed Accessories Standard Features CE Model 025-071 5 Models: 025,

More information

CFFWA Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 12,000-60,000 BTUH

CFFWA Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 12,000-60,000 BTUH CFFWA Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 12,000-60,000 BTUH 207 CFFWA NOMENCLATURE BREAKDOWN 2-Pipe Heat/Cool Universal Mount Fan Coil CFFWA- XX - 1 - U 2-Pipe Heat/Cool

More information

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Single stage cooling capacity control on all 0 241 models Two stage cooling capacity control on

More information

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES EER 8.5 ARI RATINGS* K2ES120A25 10 NOMINAL TONS WITH TWO 5 TON CIRCUITS

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES EER 8.5 ARI RATINGS* K2ES120A25 10 NOMINAL TONS WITH TWO 5 TON CIRCUITS 550.13-TG11Y (0500) SPLIT-SYSTEM EVAPORATOR BLOWER K2ES120A25 10 NOMINAL TONS WITH TWO 5 TON CIRCUITS EER 8.5 DESCRIPTION This completely assembled dual circuit evaporator blower includes a well-insulated

More information

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS 50FP-1SB 50FP034, 038, 044, 048, 054, 064, 074 SINGLE-PACKAGE COOLING UNITS CONSTANT/VARIABLE VOLUME PRODUCT INTEGRATED CONTROLS CARRIER COMFORT NETWORK COMPATIBLE FACTORY-INSTALLED OPTIONAL ELECTRIC HEAT

More information

R6GI Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

R6GI Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS TECHNICAL SPECIFICATIONS R6GI Series Single Packaged Gas/Electric Units 20 SEER 81% AFUE Multi-Stage Cool/Two-Stage Heat 2-5 Ton Single-Phase Units The iq Drive gas/electric packaged system features modulating

More information

REPLACEMENT PARTS MANUAL

REPLACEMENT PARTS MANUAL REPLACEMENT PARTS MANUAL WALL MOUNTED PACKAGE AIR CONDITIONER Models: HAA-A HAA-A H0AA-A HAA-A HAA-B HAA-B H0AA-B HAA-B Contents Description Page Cabinet Components Exploded View... Usage List... Usage

More information

MHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil. Heat / Cool Fan Coil 24,000 BTUH. Rev. 1.3

MHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil. Heat / Cool Fan Coil 24,000 BTUH. Rev. 1.3 MHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil Heat / Cool Fan Coil 24,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Hi-Wall Fan Coil 2-Pipe Nominal Size: 24,000 BTUH Multiaqua Model

More information

PA95 12 SEER FEATURES 2 THRU 4 TON SINGLE PACKAGE

PA95 12 SEER FEATURES 2 THRU 4 TON SINGLE PACKAGE PACKAGE AIR CONDITIONER PA95 12 SEER C 2 THRU 4 TON SINGLE PACKAGE FEATURES CONSTRUCTED FOR DURABILITY All panels made from galvanized steel pre--coated inside and out -- using a polyester top coat, on

More information

REPLACEMENT PARTS MANUAL

REPLACEMENT PARTS MANUAL REPLACEMENT PARTS MANUAL DC FREE COOLING UNIT SYSTEM AIR CONDITIONER MODELS DAPA DLPA DAPA DLPA DAPB DLPB CONTROLLER MODELS LC00 LC0 LC000 Description Page Cabinet Components Exploded View... Usage List...

More information

The Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat

The Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat Producing Quality Heating & Cooling Equipment For Over 50 Years CEA SERIES CEILING EPOSED HORIZONTAL FAN COIL UNITS The Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat

More information

GPC14H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER

GPC14H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER Cooling Capacity: 24,000-57,500 BTU/H H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data... 5 Airflow Data... 18 Heater Kit

More information

CSA6. Product Specifications. SoftSound SXC 2600

CSA6. Product Specifications. SoftSound SXC 2600 16 SEER SINGLE STAGE AIR CONDITIONER WITH OBSERVERr COMMUNICATING CONTROL SYSTEM 1½ THRU 5 TONS SPLIT SYSTEM 208 / 2 Volt, 1- phase, 60 Hz REFRIGERATION CIRCUIT S Copeland Scroll compressors on all models

More information

Q6SE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase

Q6SE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS Q6SE Series Single Packaged Heat Pump, Single Phase Q6SE-14 SEER, 8.0 HSPF 2-5 Ton Units Cooling: 23,000 to 58,000 Btuh Heating: 22,800 to 59,000 Btuh The Q6 Series single packaged

More information

Product Data PH3Z 13 SEER SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -22 REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS ( )

Product Data PH3Z 13 SEER SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -22 REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS ( ) 13 SEER SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -22 REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS (024-0) Product Data Fig. 1 - Unit 664B Single -Packaged Heat Pump Units with: S easy installation

More information

S6BQ Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Split System 2-Stage Air Conditioner. 7 1/2 and 10 Ton rated at 11.2 EER and 12.

S6BQ Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Split System 2-Stage Air Conditioner. 7 1/2 and 10 Ton rated at 11.2 EER and 12. TECHNICAL SPECIFICATIONS S6BQ Series Split System 2-Stage Air Conditioner 7 1/2 and 10 Ton rated at 11.2 EER and 12.9 IEER The S6BQ Series of air conditioners offers exceptional performance. The unit,

More information

MERIT Series R-410A - Upflow / Horizontal - Variable Speed

MERIT Series R-410A - Upflow / Horizontal - Variable Speed PRODUCT SPECIFICATIONS AIR HANDLERS CBX5UHV (-01) MERIT Series R-10A - Upflow / Horizontal - Variable Bulletin No. 10611 March 015 Supersedes November 01 MODEL NUMBER IDENTIFICATION CB X 5 UH V - 00-0

More information

PACKAGE AIR CONDITIONERS

PACKAGE AIR CONDITIONERS PACKAGE AIR CONDITIONERS FORM NO. S22-92 REV. 2 Supersedes Form No. S22-92 Rev. RLNA- SUPER HIGH EFFICIENCY SERIES NOMINAL SIZES -5 TONS [0.6-7.6 kw] *Unit shown with optional louver panels installed..0

More information

50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS

50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS R FORM NO: MS0305F Products That Perform...By People Who Care AIR - COOLED SPLIT SYSTEM AIR CONDITIONERS WITH SCROLL COMPRESSORS 50 Hz COOLING CAPACITY- 60 MBH TO 1360 MBH ACCS SERIES HEB-D, EB-D SERIES

More information

AIR HANDLERS RBHM- SERIES AIR HANDLERS AND FAN COIL UNIT

AIR HANDLERS RBHM- SERIES AIR HANDLERS AND FAN COIL UNIT FORM NO. H11-521 AIR HANDLERS earth friendly refrigerant RBHM- SERIES AIR HANDLERS AND FAN COIL UNIT Features Versatile 3-way convertible design for upflow, horizontal left and horizontal right. Available

More information

DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS SUPPLY AIR PLENUMS

DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS SUPPLY AIR PLENUMS DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS These completely assembled units include a well-insulated cabinet, a DX cooling coil

More information

N4A6. Product Specifications

N4A6. Product Specifications ENVIRONMENTALLY SOUND REFRIGERANT N4A6 Product Specifications EFFICIENT UP TO 16.5 SEER/12.2 13.0 EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208/2 Volt,

More information

CDI series. Engineering Submittal Sheet. Model SM Residential Geothermal Heat Pump. Standard Features. Overview and Certifications

CDI series. Engineering Submittal Sheet. Model SM Residential Geothermal Heat Pump. Standard Features. Overview and Certifications CDI series Model SM Residential Geothermal Heat Pump Engineering Submittal Sheet Overview and Certifications Standard Features and Field Installed Accessories Standard Features White Pre-Painted Sheet

More information

CDI series. Engineering Submittal Sheet. Model SM Residential Geothermal Heat Pump. Standard Features. Overview and Certifications

CDI series. Engineering Submittal Sheet. Model SM Residential Geothermal Heat Pump. Standard Features. Overview and Certifications CDI series Model SM Residential Geothermal Heat Pump Engineering Submittal Sheet Overview and Certifications Standard Features, Factory Installed Options, and Field Installed Accessories Standard Features

More information

EFFICIENCY 17 SEER TWO STAGE AIR CONDITIONER WITH OBSERVER

EFFICIENCY 17 SEER TWO STAGE AIR CONDITIONER WITH OBSERVER ENVIRONMENTALLY SOUND REFRIGERANT HCA7 QuietComfort DXT+ Product Specifications HIGH EFFICIENCY 17 SEER TWO STAGE AIR CONDITIONER WITH OBSERVER COMMUNICATING CONTROL SYSTEM 2 THRU 5 TONS SPLIT SYSTEM 208/230

More information

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS Q6SD Series Single Packaged Heat Pump, Single Phase Q6SD-13 SEER, R-410A 2-5 Ton Units Cooling: 22,800 to 58,500 Btuh Heating: 22,800 to 58,500 Btuh The Q6 Series single packaged

More information

REFRIGERANT SYSTEM R410A Refrigerant High efficiency compressor Copper tubing with enhanced fin coils

REFRIGERANT SYSTEM R410A Refrigerant High efficiency compressor Copper tubing with enhanced fin coils MHP4 Electric Heat Pump Packaged Thru-the-Wall Units FEATURES Up to 10.4 EER cooling efficiency Completely self-contained heating and cooling package No outside condensing unit No external refrigerant

More information

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS TECHNICAL SPECIFICATIONS S5BP Series Split System Air Conditioner 71/2 Ton Energy Star rated at 11.7 EER and 11.8 IEER 10 Ton rated at 11.2 EER and 11.5 IEER R-410A Refrigerant The S5BP Series of air conditioners

More information

14 SEER R -410A PACKAGE GAS / ELECTRIC UNIT 2 to 5 TON

14 SEER R -410A PACKAGE GAS / ELECTRIC UNIT 2 to 5 TON 14 SEER R -410A PACKAGE GAS / ELECTRIC UNIT 2 to 5 TON Two -Stage Gas Heating/Two -Stage Electric Cooling REFRIGERATION CIRCUIT All models are equipped with high efficiency two--stage Copeland UltraTech

More information

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES FFMA Base Series Fan Coil Sizes 018 thru 037 Product Data A13417 FEATURES The FFMA Series Fan Coil unit is primarily designed for apartment applications as an upflow only indoor fan coil for split -system

More information

Product Data FFMA BASE SERIES FAN COIL SIZES 018 TO 037 FEATURES

Product Data FFMA BASE SERIES FAN COIL SIZES 018 TO 037 FEATURES FFMA BASE SERIES FAN COIL SIZES 018 TO 037 Product Data A13417 FEATURES The FFMA Series Fan Coil unit is primarily designed for apartment applications as an upflow only indoor fan coil for split- system

More information

TSA6. Product Specifications. SmartComfort TXC 5600

TSA6. Product Specifications. SmartComfort TXC 5600 ENVIRONMENTALLY SOUND REFRIGERANT TSA6 SmartComfort TXC 5600 Product Specifications 16 SEER SINGLE STAGE AIR CONDITIONER WITH OBSERVER COMMUNICATING CONTROL SYSTEM 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230

More information

WATER SOURCE HEAT PUMPS

WATER SOURCE HEAT PUMPS HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS AND WATER COOLED AIR CONDITIONERS HORIZONTAL & VERTICAL MODELS 1/2-5 TONS GENERAL All Models 1 2-5 tons ship as factory-charged packages. Horizontal (HWP) units

More information

AIR HANDLERS UBHN- SERIES AIR HANDLERS AND FAN COIL UNIT PRELIMINARY NOT FOR DISTRIBUTION

AIR HANDLERS UBHN- SERIES AIR HANDLERS AND FAN COIL UNIT PRELIMINARY NOT FOR DISTRIBUTION FORM NO. H22-522 AIR HANDLERS earth friendly refrigerant PRELIMINARY NOT FOR DISTRIBUTION UBHN- SERIES AIR HANDLERS AND FAN COIL UNIT Features Versatile 3-way convertible design for upflow, horizontal

More information

ZHA/ZHB SERIES WARNING

ZHA/ZHB SERIES WARNING Service Literature Corp. 09-L Revised 7-08 ZHA/ZHB SERIES, 4, 5 and 6 ton 0.6 to kw ZHA/ZHB06, 048, 060, 07 The ZHA/ZHB packaged electric heat pump units are available in standard cooling efficiency (06S,

More information

GQ6SD Series. Single Packaged Heat Pump 13 SEER, R-410A 2-5 Ton Units TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY

GQ6SD Series. Single Packaged Heat Pump 13 SEER, R-410A 2-5 Ton Units TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY TECHNICAL SPECIFICATIONS GQ6SD Series Single Packaged Heat Pump 13 SEER, R-410A 2-5 Ton Units The GQ6 Series single packaged units are high efficiency self contained cooling and heating units that can

More information

DF6SF Series Rev B TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

DF6SF Series Rev B TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS TECHNICAL SPECIFICATIONS DF6SF Series Rev B Two-Stage Heat/Two-Stage Cool with Variable Speed Blower ihybrid Dual Fuel Package Units DF6SF 15 SEER, 81% AFUE, 8.0 HSPF 2 Ton thru 5 Ton Units These dual

More information

N4A4 C. Product Specifications

N4A4 C. Product Specifications COASTAL 14 SEER AIR CONDITIONER 14 SEER/11.5 12.5 EER R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Scroll compressors on all models Filter drier

More information

Product Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES

Product Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES Base Series Fan Coil Sizes 018 thru 036 Product Data FEATURES The Series Fan Coil unit is primarily designed for apartment applications as upflow indoor air handlers for split system heat pumps and air

More information

PCB COMMERCIAL SERIES

PCB COMMERCIAL SERIES PCB COMMERCIAL SERIES 50 Hz SELF-CONTAINED PACKAGE CONDITIONER 7½, 0, AND 5 TON [6.4 kw to 5.8 kw] COOLING CAPACITY: 90,000 TO 80,000 BTU/H The PCB Commercial 50 Hz self-contained packaged air conditioner

More information

CAC SERIES 12-1/2 Thru 20 Ton

CAC SERIES 12-1/2 Thru 20 Ton CAC SERIES 12-1/2 Thru 20 Ton SPLIT SYSTEM COMMERCIAL AIR CONDITIONER CONSTRUCTION Triple step pre--painted galvanized steal pre--coated inside and out -- using a polyester top coat, over a urethane primer

More information

MCE4 MCE4. Electric Heating / Electric Cooling Packaged Thru-the-Wall Units

MCE4 MCE4. Electric Heating / Electric Cooling Packaged Thru-the-Wall Units MCE4 Electric Heating / Electric Cooling Packaged Thru-the-Wall Units Form No.: MCE4-100 (07/2011) features Up to 10.4 EER cooling efficiency Completely self-contained heating and cooling package No outside

More information

CPC Commercial. 7½- to 12½-Ton Three-Phase. up to 11.5 EER. Cooling Capacity: 90, ,000 BTU/h. Packaged Air Conditioners

CPC Commercial. 7½- to 12½-Ton Three-Phase. up to 11.5 EER. Cooling Capacity: 90, ,000 BTU/h. Packaged Air Conditioners CPC Commercial Cooling Capacity: 90,000 118,000 BTU/h 7½- to 12½-Ton Three-Phase Packaged Air Conditioners up to 11.5 EER Standard Features R-410A chlorine-free refrigerant High-efficiency scroll compressor

More information

Models: W30A2, W36A2. Contents. Control Panel. Blower Assembly. Bard Manufacturing Company, Inc. Bryan, Ohio 43506

Models: W30A2, W36A2. Contents. Control Panel. Blower Assembly. Bard Manufacturing Company, Inc. Bryan, Ohio 43506 REPLACEMENT PARTS MANUAL WALL MOUNTED PACKAGE AIR CONDITIONER Models: W30A, W36A General Notes Revised and/or additional pages may be issued from time to time. A complete and current manual consists of

More information

PACKAGED HEAT PUMP AIR HANDLER UNITS, 6 25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

PACKAGED HEAT PUMP AIR HANDLER UNITS, 6 25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Product Specifications COMMERCIAL PACKAGED HEAT PUMP AIR HANDLER UNITS, 6 25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Multi position design for horizontal or vertical installation without modification

More information

24CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V)

24CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V) 24CWA4-HW 4-Pipe Chilled & Hot Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 24,000 BTUH Rev. 1.2 HVAC Guide Specifications Chilled & Hot Multi-Position Fan Coil 4-Pipe Nominal Size: 24,000 BTUH Multiaqua

More information

VHIA High-Static Ducted Indoor Units - 60HZ

VHIA High-Static Ducted Indoor Units - 60HZ PRODUCT SPECIFICATIONS Compact design for limited space requirements. Installs out of sight between the drop ceiling and ceiling slab with ducted distribution to the indoor space. All models have three-stage

More information

VWMB Wall-Mounted Non-Ducted Indoor Models - 60HZ

VWMB Wall-Mounted Non-Ducted Indoor Models - 60HZ PRODUCT SPECIFICATIONS VARIABLE REFRIGERANT FLOW SYSTEMS VRF VWMB Wall-Mounted Non-Ducted Indoor Models - 60HZ Bulletin No. 210712 March 2018 Low-sound, three-speed Wall Mount with LED display offers three

More information

R4H4. Product Specifications

R4H4. Product Specifications ENVIRONMENTALLY SOUND REFRIGERANT R4H4 Product Specifications EFFICIENT 14 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION

More information

MCE4 FEATURES REFRIGERANT SYSTEM CABINET BLOWER CONTROLS INSTALLATION WARRANTY. Electric Heating / Electric Cooling Packaged Units

MCE4 FEATURES REFRIGERANT SYSTEM CABINET BLOWER CONTROLS INSTALLATION WARRANTY. Electric Heating / Electric Cooling Packaged Units Electric Heating / Electric Cooling Packaged Units FORM NO. -100 (06/2017) FEATURES Up to 10.0 EER cooling efficiency Less than 2% cabinet air leakage Completely self-contained heating and cooling package

More information

Q3RD Series. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

Q3RD Series. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS TECHNICAL SPECIFICATIONS Q3RD Series Single Packaged Heat Pump, Single Phase Q3RD-13 SEER 2 thru 4 Ton Units Cooling: 24,000 to 48,000 Btuh Heating: 23,200 to 48,000 Btuh The Q3 Series single packaged

More information

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS 50Hz Single Package Rooftop, Cooling Only with Puronr (R---410A) Refrigerant One Stage Cooling Capacity Control: Size 07 Two Stage Cooling Capacity Control: Sizes 08, 09, 12 & 14 Submittal Data PERFORMANCE

More information

Geo-Trio High Efficiency Geothermal/Water Source Step-Capacity Heat Pump R-410A

Geo-Trio High Efficiency Geothermal/Water Source Step-Capacity Heat Pump R-410A Geo-Trio High Efficiency Geothermal/Water Source Step- Heat Pump R-410A Ground Water Application: Water Temp to Ground Loop Application: Temp Range to The Bard Geo-Trio Geothermal/Water Source Heat Pump

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model PPG2GI M1200 Product Line Single Packaged Gas/Electric Units 20 SEER, 81% AFUE 2-5 Ton Units Multi-Stage Cool / Two-Stage Heat The iq Drive gas/electric packaged system features

More information

FS Fan-Coil Units Hi-Rise, Vertical

FS Fan-Coil Units Hi-Rise, Vertical FS Fan-Coil Units Hi-Rise, Vertical FSC Concealed Dimensional Data 4-PIPE 2-PIPE TOP VIEWS Page Trims Short (5/8") Here! SIDE VIEW FRONT VIEW Dimensions Unit Size A B Single/Double Supply C D E 03 & 04

More information

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ DESCRIPTION FEATURES

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ DESCRIPTION FEATURES (791) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ H1CE180 & 240 15 AND 20 NOMINAL TONS (60 HZ) 13 AND 17-1/2 NOMINAL TONS (50 HZ) SUNLINE 2000 DESCRIPTION These Sunline 2000 units are completely

More information

PAB SERIES 3thru6-1/3Ton. Belt Drive 10 SEER CONVERTIBLE SINGLE PACKAGE AIR CONDITIONING UNIT /01

PAB SERIES 3thru6-1/3Ton. Belt Drive 10 SEER CONVERTIBLE SINGLE PACKAGE AIR CONDITIONING UNIT /01 PAB SERIES 3thru6-1/3Ton Belt Drive CONVERTIBLE SINGLE PACKAGE AIR CONDITIONING UNIT 10 SEER SINGLE PACKAGE Electric cooling, self contained for year-round comfort. Systems can be installed on roof top

More information

HCH6. Product Specifications

HCH6. Product Specifications HCH6 Product Specifications HIGH EFFICIENCY 16 SEER TWO- STAGE HEAT PUMP WITH OBSERVERt COMMUNICATING CONTROL SYSTEM 2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt, 1- phase, 60 Hz REFRIGERATION CIRCUIT S Copeland

More information