Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed.

Size: px
Start display at page:

Download "Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed."

Transcription

1 THE WALL-MOUNT AIR CONDITIONER -. EER, (HZ) Models WAA to W7AA Right-ide Control Panel Models WLA to W7LA Left-ide Control Panel. to Ton (7, to 7, Btuh) The Bard Wall-Mount Air Conditioner is a self contained energy efficient system, which is designed to offer maximum indoor comfort at a minimal cost without using valuable indoor floor space or outside ground space. This unit is the ideal product for versatile applications such as: new construction, modular offices, school modernization, telecommunication structures, portable structures or correctional facilities. Factory or field installed accessories are available to meet specific job requirements. Green Refrigerant R-A Engineered Features Aluminum Finned Copper s: Grooved tubing and enhanced louvered fin for maximum heat transfer and energy efficiency. Twin Blowers: Move air quietly. Most models feature multispeed blower motors providing airflow adjustment for high and low static operation. Motor overload protection is standard on all models. Electrical Components: Are easily accessible for routine inspection and maintenance through a right side, service panel opening. Features a lockable, hinged access cover to the circuit breaker or toggle disconnect switch. Electric Heat trips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed. Air Conditioner Compressor: croll Compressors eliminate need for crankcase heater. tandard on all models, except -Ton. R-A Refrigerant: Designed with R-A (HFC) non-ozone depleting refrigerant in compliance with the Montreal protocol and EPA requirements. Phase Rotation Monitor: tandard on all 3-phase scroll compressors. Protects against reverse rotation if power supply is not properly connected. Galvanized Gauge Zinc Coated teel Cabinet: Cleaned, rinsed, sealed and dried before the polyurethane primer is applied. The cabinet is handsomely finished with a baked on textured enamel, which allows it to withstand hours of salt spray tests per ATM B7-3. Foil Faced Insulation: tandard on all units. Full Length Mounting Brackets: Built into cabinet for improved appearance and easy installation. NOTE: Bottom mounting bracket included to assist in installation. Filter ervice Door: eparate service door provides easy access for filter change. One Inch, Disposable Air Filters: Are standard equipment. Optional one inch washable filters available and filter racks permit the addition of " pleated filter. Factory or field installed. Condenser Fan and Motor hroud Assembly: lides out for easy access. Barometric Fresh Air Damper: tandard on all units. Allows up to % outside fresh air. Optional ventilation packages available. Built-in Circuit Breakers: tandard on all electric heat versions of single (3/ volt) and three phase (3/ volt) equipment. Toggle disconnects are standard on all electric heat versions of three phase ( volt) equipment. lope Top: tandard feature for water run-off. Top Rain Flashing: tandard feature on all models. Freezestat: tandard on W7 models. Optional field installed CMC- can be used on all other models. Complies with efficiency requirements of AHRAE/IENA.-3. Certified to ANI/ARI tandard 3-3 for PVU (ingle Package Vertical Units). Intertek ETL Listed to tandard for afety Heating and Cooling Equipment ANI/UL /CA. No. 3-, Fourth Edition. Commercial Product - Not intended for Residential application. Liquid Line Filter Drier: tandard on all units. Protects system against moisture. Compressor Control Module: tandard on all units. Built-in offdelay timer adjustable from 3 seconds to minutes. -minute on-delay if power interrupt. -second bypass for low pressure control, and both soft and manual lockouts for high and low pressure controls. Alarm output for alarm relay. High & Low Pressure witches are Auto- Reset: tandard on all units. Built-in lockout circuit resets from the room thermostat. Provides commercial quality protection to the compressor.

2 Capacity and Efficiency Ratings Models WAA WLA WAA WLA W3AA W3LA W3AA W3LA Capacity is certified in accordance with ANI/ARI tandard 3-3. EER = Energy Efficiency Ratio and is certified in accordance with ANI/ARI tandard 3-3. All ratings based on fresh air intake being % closed (no outside air introduction). WAA WLA WAA WLA WAA WLA W7AA W7LA Cooling Capacity BTUH 7,, 3, 3,,,, 7, EER pecifications -/ Ton through 3 Ton MODEL WAA-A WLA-A WAA-A WLA-A WAA-B WLA-B WAA-C W3AA-A W3LA-A W3AA-B W3LA-B W3AA-C W3LA-C W3AA-A W3LA-A W3AA-B W3LA-B W3AA-C W3LA-C Electrical Rating Hz 3/ - 3/ - 3/ / - 3/ / - 3/ Operating Voltage Range Compressor--Circuit A Voltage 3/ 3/ 3/ 3/ 3/ 3/ 3/ Rated Load Amps./../../..3./../ /./.. Branch Circuit election Current Lock Rotor Amps / / / 77/77 7/7 3 / / Compressor Type croll croll croll croll croll croll croll croll croll croll Fan Motor & Condenser Fan Motor--HP--RPM / - / - / - / - / - / - / - / - / - / - Fan Motor--Amps Fan--DIA/CFM " - " - " - " - " - " - " - " - " - " - Blower Motor & Evap. Blower Motor--HP-RPM-PD /-- /-- /-- /-- /3-- /3-- /3-- /3-- /3-- /3-- Blower Motor--Amps CFM Cooling & E..P. w/filter (Rated- ) Filter izes (inches) TD. xx xx xx xx x3x x3x x3x x3x x3x x3x hipping Weight --LB pecifications 3-/ Ton through Ton MODEL WAA-A WLA-A WAA-B WLA-B WAA-C WLA-C WAA-A WLA-A WAA-B WLA-B WAA-C WLA-C WAA-A WLA-A WAA-B WLA-B WAA-C WLA-C W7AA-A W7LA-A W7AA-B W7LA-B W7AA-C W7LA-C Electrical Rating Hz 3/- 3/-3-3 3/- 3/-3-3 3/- 3/-3-3 3/- 3/-3-3 Operating Voltage Range Compressor--Circuit A Voltage 3/ 3/ 3/ 3/ 3/ 3/ 3/ 3/ Rated Load Amps./../.. 7.3/../3.3../3. 3./ /3../.. Branch Circuit election Current Lock Rotor Amps / 3./3. / / 3/3 / / / Compressor Type croll croll croll croll croll croll croll croll croll croll croll croll Fan Motor & Condenser Fan Motor--HP--RPM-PD /3-- /3-- /3-- /3-- /3-- /3-- /3-- /3-- /3-- /-- /-- 3/-- Fan Motor--Amps Fan--DIA/CFM " - " - " - " - 3 " - 3 " - 3 " - 3 " - 3 " - 3 " - " - " - Blower Motor & Evap. Blower Motor--HP-RPM-PD /3-- /3-- /3-- /3-- /3-- /3-- /-7- /-7- /-7-3/-- 3/-- 3/-- Blower Motor--Amps CFM Cooling & E..P w/filter (Rated- ) Filter izes (inches) TD. x3x x3x x3x x3x x3x x3x x3x x3x x3x x3x x3x x3x hipping Weight --LB.

3 Ventilation ystem Packages Bard Wall-Mounts are designed to provide optional ventilation packages to meet all of your ventilation and indoor air quality requirements. All units are equipped with a barometric fresh air damper as the standard ventilation package. All ventilation packages can be built-in at the factory or field-installed at a later date. BAROMETRIC FREH AIR DAMPER - BFAD TANDARD The barometric fresh air damper is a standard feature on all models. It is installed on the inside of the service door and allows outside ventilation air, up to % of the total airflow rating of the unit, to be introduced through the air inlet openings and to be mixed with the conditioned air. The damper opens during blower operation and closes when the blower is off. Adjustable blade stops allow different amounts of outside air to be introduced into the building and can be easily locked closed if required. MI-3 Barometric Fresh Air Damper BLANK OFF PLATE - BOP OPTIONAL A blank off plate is installed on the inside of the service door. It covers the air inlet openings, which restricts any outside air from entering the unit. The blank off plate should be utilized in applications where outside air is not required to be mixed with the conditioned air. MOTORIZED FREH AIR DAMPER - MFAD OPTIONAL The motorized fresh air damper is internally mounted behind the service door and allows outside ventilation air, up to % of the total airflow rating of the unit, to be introduced through the air inlet openings and to be mixed with the conditioned air. The two position damper can be fully open or closed. The damper blade is powered open by a VAC motor with spring return on power loss. The damper can be controlled by indoor blower operation or can be field connected to be managed based on building occupancy. NOTE: The above vent systems are intake only without built-in exhaust capability. Building will likely require separate field installed barometric relief or mechanical exhaust elsewhere within the conditioned space. Balancing dampers in the return air grille may be required to achieve specified amount of outdoor air intake. Motorized Fresh Air Damper Commercial Room Ventilator MI-3 MI-3 COMMERCIAL ROOM VENTILATOR - CRV OPTIONAL The built-in commercial room ventilator is internally mounted behind the service door and allows outside ventilation air, up to % of the total airflow rating of the unit, to be introduced through the air inlet openings. It includes a built-in exhaust air damper. The commercial room ventilator (CRV) is a simple and innovative approach to improving the indoor air quality by providing fresh air intake and exhaust capability through the CRV. The damper can be easily adjusted to control the amount of fresh air supplied into the building. The CRV can be controlled by indoor blower operation or field controlled based on room occupancy. Two versions available (except on. and -Ton models). The CRV and CRV are power open - spring return on power loss, with positive shut-off. Complies with ANI/AHRAE tandard. Ventilation for Acceptable Indoor Air Quality. tandard Features: Fully modulating Honeywell Hi-Torque Actuator 7" intake hood with filter imple single blade design Positive shut-off with non-stick gaskets Enthalpy sensors Honeywell JADE electronic economizer module with precision settings and diagnostics Enthalpy economizer versions available Economizer Energy Recovery Ventilator MI-3 MI-37 ECONOMIZER WECO eries OPTIONAL The built-in economizer system is internally mounted behind the service door and allows outdoor air to be introduced through the air inlet openings. The amount of outdoor air varies in response to the system controls and settings defined by the end user. It includes a built-in exhaust air damper. The economizer is designed to provide free cooling when outside air conditions are cool and dry enough to satisfy cooling requirements without running the compressor. This in turn provides lower operating costs, while extending the life of the compressor. tandard Features: Fully modulating Honeywell Hi-Torque Actuator 7" intake hood with filter imple single blade design Positive shut-off with non-stick gaskets Electronic DB and/or Enthalpy sensors depending upon version Honeywell JADE electronic economizer module with precision settings and diagnostics DB or Enthalpy economizer versions available WALL-MOUNT ENERGY RECOVERY VENTILATOR - ERVF OPTIONAL The wall-mount energy recovery ventilator (ERV) is a highly innovative approach to meeting indoor air quality ventilation requirements as established by ANI/AHRAE tandard.. The ERV allows from to CFM (depending upon model) of fresh air and exhaust through the unit while maintaining superior indoor comfort and humidity levels. In most cases this can be accomplished without increasing equipment sizing or operating costs. Heat transfer efficiency is up to 7% during summer and % during winter conditions. The ERV consists of a unique rotary energy recovery cassette that provides effective sensible and latent heat transfer capabilities during summer and winter conditions. Various control schemes are addressed including limiting ventilation during building occupancy only. The ERV is designed to be internally mounted behind the service door in the W**A or W**L model wall-mount units. It can be built-in at the factory (W**A only) or field installed as an option. ERVF-*3 and ERVF-* can be independently adjusted for intake and exhaust rates. The ERV s have exhaust gravity shut-off dampers and motorized air intake dampers for positive shut-off.

4 Commercial Room Ventilator Performance Data - CRV- W & W Ventilation Delivery 7 Ventilation CFM Damper Position upply & Return Grilles." Duct tatic." Duct tatic Commercial Room Ventilator Performance Data - CRV-3 and CRVP-3 W3 & W3 Ventilation Delivery Ventilation CFM 3 7 Damper Position upply & Return Grilles." Duct tatic." Duct tatic

5 Commercial Room Ventilator Performance Data - CRV- and CRVP- W & W Ventilation Delivery Ventilation CFM 3 7 Damper Position upply & Return Grilles." Duct tatic." Duct tatic W Ventilation Delivery Ventilation CFM 3 7 Damper Position upply & Return Grilles." Duct tatic." Duct tatic W7 Ventilation Delivery Ventilation CFM 3 7 Damper Position upply & Return Grilles." Duct tatic." Duct tatic

6 Performance and Application Data- ERVF-A Ambient O.D. VENTILATION RATE -- CFM % EFFICIENCY UMMER COOLING PERFORMANCE (INDOOR DEIGN CONDITION DB/ WB) VENTILATION RATE -- CFM 3% EFFICIENCY VENTILATION RATE -- CFM 3% EFFICIENCY DB/WB F VLT VL VLL HRT HR HRL VLT VL VLL HRT HR HRL VLT VL VLL HRT HR HRL Ambient O.D. ERVF-A WINTER HEATING PERFORMANCE (INDOOR DEIGN CONDITION 7 F DB) VENTILATION RATE CFM 7% EFF. CFM % EFF. CFM % EFF. DB/ F WVL WHR WVL WHR WVL WHR NOTE: ensible performance only is shown for winter application. LEGEND: VLT = Ventilation Load - Total VL = Ventilation Load - ensible VLL = Ventilation Load - Latent HRT = Heat Recovery - Total HR = Heat Recovery - ensible HRL = Heat Recovery - Latent WVL = Winter Ventilation Load WHR = Winter Heat Recovery

7 Performance and Application Data- ERVF-*3 Performance and Application Data- ERVF-* Ambient O.D. DB/ WB VENTILATION RATE -- CFM 3% EFFICIENCY UMMER COOLING PERFORMANCE (INDOOR DEIGN CONDITION DB/ WB) VENTILATION RATE -- 3 CFM % EFFICIENCY VENTILATION RATE -- CFM % EFFICIENCY F VLT VL VLL HRT HR HRL VLT VL VLL HRT HR HRL VLT VL VLL HRT HR HRL Ambient O.D. DB/ WB VENTILATION RATE -- CFM 3% EFFICIENCY UMMER COOLING PERFORMANCE (INDOOR DEIGN CONDITION DB/ WB) VENTILATION RATE -- 3 CFM % EFFICIENCY VENTILATION RATE -- CFM % EFFICIENCY F VLT VL VLL HRT HR HRL VLT VL VLL HRT HR HRL VLT VL VLL HRT HR HRL Ambient O.D. ERVF-*3 WINTER HEATING PERFORMANCE (INDOOR DEIGN CONDITION 7 F DB) CFM % EFFICIENCY VENTILATION RATE 3 CFM 7% EFFICIENCY CFM 77% EFFICIENCY LEGEND: VLT = Ventilation Load - Total VL = Ventilation Load - ensible VLL = Ventilation Load - Latent HRT = Heat Recovery - Total HR = Heat Recovery - ensible HRL = Heat Recovery - Latent WVL = Winter Ventilation Load WHR = Winter Heat Recovery DB/ F WVL WHR WVL WHR WVL WHR NOTE: ensible performance only is shown for winter application. Ambient O.D. ERVF-* WINTER HEATING PERFORMANCE (INDOOR DEIGN CONDITION 7 F DB) CFM % EFFICIENCY VENTILATION RATE 3 CFM % EFFICIENCY 3 CFM % EFFICIENCY DB/ F WVL WHR WVL WHR WVL WHR NOTE: ensible performance only is shown for winter application.

8 Electrical pecifications W**AA eries MODEL WAA-A,AZ A A A WAA-A, AZ A A A A WAA-B, BZ Rated Volts & Phase 3/- 3/- No. Field Power Circuits B 3/-3 WAA-C, CZ -3 C W3AA-A*, AZ* A* A 3/- A* A or W3AA-B*, BZ* B B* B W3AA-C*, CZ* C C* C C W3AA-A*, AZ* A* A A* A W3AA-B*, BZ* B* B* B W3AA-C*, CZ* C* C* C C WAA-A, AZ A A A A WAA-B, BZ B B B WAA-C, CZ C C WAA-A, AZ A A A A WAA-B, BZ B B B WAA-C, CZ C C WAA-A, AZ A A A A WAA-B, BZ B B B WAA-C, CZ C C W7AA-A, AZ A A A A W7AA-B, BZ B B B W7AA-C, CZ C 3/-3-3 3/- 3/-3-3 3/- 3/-3-3 3/- 3/-3-3 3/- 3/-3-3 3/- 3/-3-3 or or or or or or or or or 3 Minimum Circuit Ampacity ingle Circuit Maximum External Fuse or Ckt. Brkr Field Power Wire ize 3 3 Ground Wire Multiple Circuit Minimum Maximum Circuit External Fuse Field Power Ground Ampacity or Ckt. Breaker Wire ize Wire ize Ckt. A Ckt. B Ckt. C Ckt. A Ckt. B Ckt. C Ckt. A Ckt. B Ckt. C Ckt. A Ckt. B Ckt. C 3 3 C 7 3 Maximum size of the time delay fuse or HACR type circuit breaker for protection of field wiring conductors. Based on C copper wire. All wiring must conform to the National Electrical Code and all local codes. These Minimum Circuit Ampacity values are to be used for sizing the field power conductors. Refer to the National Electrical code (latest version), Article 3 for power conductor sizing. Caution: When more than one field power circuit is run through one conduit, the conductors must be derated. Pay special attention to note of Table 3 regarding Ampacity Adjustment Factors when more than three (3) current carrying conductors are in a raceway. * Top outlet supply option is available only factory installed and only on the selected models. IMPORTANT: While this electrical data is presented as a guide, it is important to electrically connect properly sized over-current protection and conductor wires in accordance with the National Electrical Code and all local codes

9 Electrical pecifications W**LA eries MODEL WLA-A,AZ A A A WLA-A, AZ A A A WLA-B, BZ Rated Volts & Phase 3/- 3/- No. Field Power Circuits B 3/-3 WLA-C, CZ -3 C W3LA-A, AZ A A 3/- A A or W3LA-B, BZ B B W3LA-C, CZ C C W3LA-A, AZ A A A W3LA-B, BZ B B W3LA-C, CZ C C WLA-A, AZ A A A WLA-B, BZ B B WLA-C, CZ C C WLA-A, AZ A A A WLA-B, BZ B B WLA-C, CZ C C WLA-A, AZ A A A WLA-B, BZ B B WLA-C, CZ C C W7LA-A, AZ A A A W7LA-B, BZ B B W7LA-C, CZ C C 3/-3-3 3/- 3/-3-3 3/- 3/-3-3 3/- 3/-3-3 3/- 3/-3-3 3/- 3/-3-3 or or or or or Minimum Circuit Ampacity ingle Circuit Maximum External Fuse or Ckt. Brkr Field Power Wire ize 3 3 Ground Wire Dual Circuit Minimum Maximum Circuit External Fuse Field Power Ground Ampacity or Ckt. Breaker Wire ize Wire ize Ckt. A Ckt. B Ckt. A Ckt. B Ckt. A Ckt. B Ckt. A Ckt. B Maximum size of the time delay fuse or HACR type circuit breaker for protection of field wiring conductors. Based on C copper wire. All wiring must conform to the National Electrical Code and all local codes. These Minimum Circuit Ampacity values are to be used for sizing the field power conductors. Refer to the National Electrical code (latest version), Article 3 for power conductor sizing. Caution: When more than one field power circuit is run through one conduit, the conductors must be derated. Pay special attention to note of Table 3 regarding Ampacity Adjustment Factors when more than three (3) current carrying conductors are in a raceway. * Top outlet supply option is available only factory installed and only on the selected models. IMPORTANT: While this electrical data is presented as a guide, it is important to electrically connect properly sized over-current protection and conductor wires in accordance with the National Electrical Code and all local codes. 3

10 Indoor Blower Performance ( Hz) - CFM at Rated Voltage peed W W W3 W3 W W W W7 High Low ingle High Low High Low High Low High Low High Low High Low EP (Inch H) Above data is with " standard throwaway filter and " washable filter. For optional " pleated filter - reduce EP by. in. ee installation instructions for maximum EP information on various KW application. Factory Connected peed. Electric Heat Table - Refer to Electrical pecifications for Availability by Unit Model Nominal KW Kw At V () At V () At V () At V () -Ph Amps 3-Ph Amps Btuh Kw -Ph Amps 3-Ph Amps Btuh Kw 3-Ph Amps Btuh Kw 3-Ph Amps Btuh...7 3, 3..,3... 7, 3..,7...,7..,. 7.,7.., ,3.., , ,3.. 3,77..,...7 3, ,... 3., ,3.., ,.. 3.3, ,7..7,3..,.. 3.3,. 7., () These electric heaters are available in 3/V units only. () These electric heaters are available in V units only.

11 Heater Packages - Field Installed "A" eries Right-Hand Units Designed for adding Electric Heat to KW Units ETL U & Canada Listed Circuit Breaker tandard on 3/V Models Toggle Disconnect tandard on V Models Air Conditioner -A Models 3/- -B Models 3/-3 -C Models -3 Models Heater Model # KW Heater Model # KW Heater Model # KW WAA EHWA-AB EHWA-AB EHWAA-AB WAA EHWAA-AB EHWA-AB EHWA-AB EHWAA-AB EHWA-BB EHWHB-C W3AA EHWA3-AB EHWA3-AB EHWA3-AB EHWA3-AB EHWA3-BB EHWA3-BB EHWA37-BB EHWC3A-C EHWC3A-C EHWA3A-C EHWA3A-C W3AA EHWA3-AB EHWA3-AB EHWA3-AB EHWA3-AB EHW3A-BB EHWA3-BB EHWA37-BB EHWC3A-C EHWC3A-C EHWA3A-C EHWA3A-C WAA WAA EHWTA-A EHWA-AB EHWA-AB EHWA-AB EHWA-BB EHWA-BB EHWTA-B EHWTA-C EHWTA-C WAA EHWTA-A EHWA-AB EHWA-AB EHWA-AB EHWA-BB EHWA-BB EHWTA-B EHWTA-C EHWTA-C W7AA EHWTA-A EHWA-A EHWA-A EHWA-A EHW7A-BB EHWA-BB EHWTA-B EHWAA-C EHWTA-C NOTE: Field installed Heater Packages are not approved for use with top supply opening models. These heater packages approved for use in dehumidification versions with hot gas reheat. Heater Packages - Field Installed "L" eries Left-Hand Units Air Conditioner Models -A Models 3/- -B Models 3/-3 -C Models -3 Heater Model # KW Heater Model # KW Heater Model # KW WLA EHWAA-ALB EHWA-ALB EHWA-ALB WLA EHWAA-ALB EHWA-ALB EHWA-ALB EHWA-BLB W3LA EHWA3-ALB EHWA3-ALB EHWA3-ALB EHWA3-ALB EHWA3-BLB EHWA37-BLB EHWC3-CL EHWA3-CL W3LA EHWA3-ALB EHWA3-ALB EHWA3-ALB EHWA3-BLB EHWA37-BLB EHWC3-CL EHWA3-CL WLA WLA EHWTA-AL EHWA-ALB EHWA-ALB EHWA-BLB EHWA-BLB EHWTA-CL EHWTA-CL WLA EHWTA-AL EHWA-ALB EHWA-ALB EHWA-BLB EHWA-BLB EHWTA-CL EHWTA-CL W7LA EHWTA-AL EHWA-AL EHWA-AL EHW7A-BL EHWA-BL EHWTA-CL EHWTA-CL

12 Clearances Required for ervice Access and Adequate Condenser Inlet Airflow MODEL LEFT IDE RIGHT IDE WAA, WAA, W3AA, W3AA " " WAA, WAA, WAA, W7AA " " NOTE: For side-by-side installation of two () WA models, there must be " between units. This can be reduced to " by using a WL model (left side compressor and controls) for the left unit and WA (right side compressor and controls) for right unit. Minimum Clearances Required to Combustible Materials MODEL UPPLY AIR DUCT FIRT THREE FEET CABINET WAA, WAA " " W3AA, W3AA /" " WAA, WAA, WAA, W7AA /" " Refer to the Installation Manual for more detailed information. Dimensions of W-7A Basic Unit for Architectural & Installation Requirements (Nominal) MODEL WAA WAA W3AA W3AA WAA WAA WAA W7AA WIDTH (W) DEPTH (D) HEIGHT (H) UPPLY RETURN A B C B E F G I J K L M N O P Q R T W Built In Rain Hood Pitch Heater Access Panel Electric Heat C. Breaker/ Disconnect Access Panel (Lockable) Hood for CRV and ECON models only D A I ide Wall Mounting Brackets (Built In) Top Rain Flashing hipping Location E O 3. upply Air Opening B. R. F G Filter Access Panel Ventilation Air Condenser Air Outlet tandard flush vent door for non- ERV/CRV Econ. models 3" 7. Low Voltage Electrical Entrance High Voltage Electrical Entrance Cond. Air Inlet J C K H Optional Electrical Entrances L M P Return Air Opening T Front View ide View Drain N Q Back View Bottom Installation Bracket MI-373 Not used when WECO Economizers installed. Filter access is through the WECO hood. k Optional top outlet (factory installed only) in place of standard front supply air opening for W3AA and W3AA models only.

13 Clearances Required for ervice Access and Adequate Condenser Inlet Airflow MODEL LEFT IDE RIGHT IDE WLA, WLA, W3LA, W3LA " " WLA, WLA, WLA, W7LA " " NOTE: For side-by-side installation of two () WL models, there must be " between units. This can be reduced to " by using a WL model (left side compressor and controls) for the left unit and WA (right side compressor and controls) for right unit. Minimum Clearances Required to Combustible Materials MODEL UPPLY AIR DUCT FIRT THREE FEET CABINET WLA, WLA " " W3LA, W3LA /" " WLA, WLA, WLA, W7LA /" " Refer to the Installation Manual for more detailed information. Dimensions of W-7L Basic Unit for Architectural & Installation Requirements (Nominal) MODEL WLA WLA W3LA W3LA WLA WLA WLA W7LA WIDTH (W) DEPTH (D) HEIGHT (H) UPPLY RETURN A B C B E F G I J K L M N O P Q R T R E Heater O Pitch Access. Panel D W upply Air Opening B ide Wall Mounting Brackets (Built In) Top Rain Flashing hipping Location Built In Rain Hood.3 A I. Electric Heat C. Breaker/ Disconnect Access Panel (Lockable) tandard flush vent door for non-erv/crv Econ. models Hood for CRV and ECON models only Return Air Opening Optional Electrical Entrances C 3" Filter Access Panel Ventilation Air. F T Drain Bottom Installation Bracket Back View Q P M N L H K J Cond. Air Inlet ide View 7. Low Voltage Electrical Entrance High Voltage Electrical Entrance Condenser Air Outlet Front View G MI-3737 Not used when WECO Economizers installed. Filter access is through the WECO hood.

14 Cooling Application Data - Outdoor Temperature Model W W W3 W3 W W W W7 Return Air (DB/WB) / /7 /7 / /7 /7 / /7 /7 / /7 /7 / /7 /7 / /7 /7 / /7 /7 / /7 /7 Cooling Capacity F F F F F F F F F F F Below F (.3C), unit requires a factory or field installed low ambient control. Return air temperature Capacity Multiplier Factors % of Rated Airflow - Rated + Total BTUH... ensible BTUH...

15 Air Conditioning Wall-Mount Model Nomenclature W 3 A A A X X X X X X ERIE NOMINAL CAPACITY - ½ Ton - Ton 3 - ½ Ton 3-3 Ton - 3½ Ton - Ton - Ton 7 - Ton A = Compressor & Controls - Right ide L = Compressor & Controls - Left ide D = DEHUMIDIFICATION OPTION Models W3A, W3A, WA, WA & WA only. Insert D in place of dash (-). REVIION VOLT & PHAE A - 3/// B - 3///3 C - //3 KW VENTILATION OPTION (ee Table Below) FILTER OPTION X - -inch Throwaway (tandard) W - -inch Washable P - -inch Pleated (MERV ) COLOR OPTION X - Beige (tandard) - White - Buckeye Gray - Desert Brown - Dark Bronze A - Aluminum - tainless teel CONTROL MODULE (ee Chart Below) COIL OPTION X - tandard - Phenolic Coated Evaporator - Phenolic Coated Condenser 3 - Phenolic Coated Evaporator and Condenser UPPLY AIR OUTLET X - Front (tandard) T - Top (on W3A and W3A Models) For KW and circuit breakers (3/ Volt) or toggle disconnects ( Volt) applications, insert Z in the KW field of the model number. ee Pages & for available Factory Installed KW options and Page for Field Installed Heater Packages. Ventilation Options Models WAA, WAA W3AA, W3AA WAA, WAA, WAA, W7AA WLA, WLA W3LA, W3LA WLA, WLA, WLA, W7LA Description Factory Installed Field Installed Factory Installed Field Installed Factory Installed Field Installed Code No. Part No. Code No. Part No. Code No. Part No. Barometric Fresh Air Damper - tandard X WBFAD- X WBFAD-3 X WBFAD- Blank-Off Plate B WBOP- B WBOP-3 B WBOP- Motorized Fresh Air Damper w/plug, -Ton M WMFADP M WMFADP3 M WMFADP Commercial Ventilator - pring Return w/plug & Exhaust m V WCRVP-* k V WCRVP3-* k V WCRVP-* k Economizer w/plug, -Ton, Temp Only m Y WECOPT-* k Y WECOPT3-* k Y WECOPT-* k Economizer w/plug, -Ton, Enthalpy m Z WECOPE-* k Z WECOPE3-* k Z WECOPE-* k Energy Recover Ventilator w/plug, -Ton, 3 Volt R WERVPA-* j R WERVPA3-* j R n WERVPA-* j Energy Recover Ventilator w/plug, -Ton, Volt R WERVPC-* j R WERVPC3-* j R n WERVPC-* j Door Kit for ERVF (Required) WMDK- l WMDK3- l WMDK- l Intake and exhaust can be independently adjusted. Insert color to match unit ("X" = Beige; "" = Buckeye Gray; etc.) WMDK Door Kit must be ordered in addition to ERVF Assembly & color matched to unit ("X" = Beige; "" = Buckeye Gray; etc.) m All Economizer & CRV versions have 7" deep intake hood. n Energy Recovery Ventilator must be field-installed on W**L models. Also see Note. Air Conditioning Control Modules All Models Except As Noted HPC LPC CCM LAC ALR K K ODT DDC Factory Installed Code Field Installed Part TD TD TD X TD TD TD E CMA- TD TD TD J Factory Only TD TD TD K CMC- and CMA- TD TD TD M Factory Only TD TD TD N TD TD TD Field Installed Only CMC- TD TD TD Field Installed Only CMA- TD TD TD V Factory Only CMA-3 for W-3 TD TD TD Field Installed Only CMA-3 for W-7 K Except W & 7 TD TD TD Field Installed Only K W7 Only K W Only TD = tandard equipment for these specified models. HPC. High pressure control is auto reset. Always used with compressor control module (CCM) which is included. ee note. LPC. Low pressure control is auto reset. Always used with compressor control module (CCM) which is included. ee note. CCM. Compressor control module has adjustable 3-second to -minute delay-on-break timer. On initial power-up, or any time the power is interrupted, the delay-on-make will be -minutes plus % of the delay-on-break setting. There is no delay-on-make during routine operation of the unit. The module also provides the lockout feature (with retry) for high and/or low pressure controls, and a -minute timed bypass for low-pressure control. LAC. Low ambient control permits cooling operation down to F. LAC is fan-cycling control for outdoor fan motor on all models except W/W Dehum. units, which have modulating control. ALR. The alarm relay has a set of normally open and normally closed dry contacts to provide the ability to signal a condition of shutdown on either high or low pressure controls. K. PTCR start kit can be used with all -A single phase models. Increases starting torque -3x. Not used for -B or -C three phase models. Do not use if K or K is used. K. tart capacitor & potential relay start kit can be used with all -A single phase models. Increases starting torque x. Not used for -B or -C three phase models. Do not use if CMC- is used. ODT. Outdoor thermostat is adjustable from to F. It is suitable for use as a compressor cut-off thermostat. DDC. Incorporates additional sensors: discharge air temperature, indoor blower airflow, compressor current, and dirty filter. These sensing devices function to input analog data such as temperature, as well as digital data such as airflow, compressor status or filter status. pecial economizer required; consult factory. V control module should be ordered in conjunction with direct digital controller (DDC) model TC. Refer to DDC specification sheet 3 for more information.

16 NOTE Form No. July, upersedes NEW

Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed.

Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed. THE WALL-MOUNT AIR CONDITIONERS -. EER, (HZ) Models WAA to W72AA Right-Side Control Panel Models WLA to W72LA Left-Side Control Panel. to Ton (7, to 7, Btuh) Green Refrigerant R-4A The Bard Wall-Mount

More information

THE WALL-MOUNT QUIET-CLIMATE HEAT PUMPS

THE WALL-MOUNT QUIET-CLIMATE HEAT PUMPS THE WALL-MOUNT QUIET-CLIMATE HEAT PUMPS Models: SH21, SH311, SH31, SH431, SH41, SH High Efficiency Heating Capacities: 21, to 55, Ultra Low Sound Level Cooling Capacities: 23, to 55, Refrigerant 22 The

More information

GREEN REFRIGERANT R-410A

GREEN REFRIGERANT R-410A s J7L to JL. to Ton (, to, Btuh) Left ide Control Panel Hz olair Wall-Mount ir Conditioner is a self contained energy efficient system, which is designed to offer maximum indoor comfort at a minimal cost

More information

GREEN REFRIGERANT R-410A

GREEN REFRIGERANT R-410A WLL-MOUNT -TON IR CONDITIONERS J7 - Right Side Control Panel J7L - Left Side Control Panel, 9.5 EER Hz Solair Wall-Mount ir Conditioner is a self contained energy efficient system, which is designed to

More information

The Wall-Mount Step Capacity Gas/Electric - WG*S Series Integrated Part Load Value (IPLV) Efficiency Up to 15.6 BTU/WATT.

The Wall-Mount Step Capacity Gas/Electric - WG*S Series Integrated Part Load Value (IPLV) Efficiency Up to 15.6 BTU/WATT. The Wall-Mount Step Capacity Gas/Electric - WG*S Series Integrated Part Load Value (IPLV) Efficiency Up to 15.6 BTU/WATT WG3S2, WG4S2, WG5S2 6HZ 24, to 56,5 BTUH Cooling Capacity 37, to 12,5 BTUH Heating

More information

THE WALL-MOUNT STEP CAPACITY HEAT PUMPS Integrated Part Load Value (IPLV) Efficiency Up To 15.0 BTU/WATT

THE WALL-MOUNT STEP CAPACITY HEAT PUMPS Integrated Part Load Value (IPLV) Efficiency Up To 15.0 BTU/WATT THE WALL-MOUNT STEP CAPACITY HEAT PUMPS Integrated Part Load Value (IPLV) Efficiency Up To 5.0 BTU/WATT Green Refrigerant R-4A Models: C24H to C0H Up to.0 EER Cooling Capacities: 22,200 to 55,0 BTUH Heating

More information

THE WALL-MOUNT AIR CONDITIONERS - WA (60HZ)

THE WALL-MOUNT AIR CONDITIONERS - WA (60HZ) THE WLL-MOUNT IR CONDITIONERS - W (HZ) W-SERIES Refrigerant 22 Hz. to Ton (, to 7, Btuh) Right Side Control Panel The Bard Wall-Mount ir Conditioner is a self contained energy efficient system, which is

More information

THE WALL-MOUNT AIR CONDITIONERS - WA (60HZ)

THE WALL-MOUNT AIR CONDITIONERS - WA (60HZ) THE WLL-MOUNT IR CONDITIONERS - W (HZ) W-SERIES Hz. to Ton (,3 to 7, Btuh) Right Side Control Panel Refrigerant The Bard Wall-Mount ir Conditioner is a self contained energy efficient system, which is

More information

GREEN REFRIGERANT R-410A

GREEN REFRIGERANT R-410A THE WALL-MOUNT STEP CAPACITY AIR CONDITIONERS Integrated Part Load Value (IPLV) Efficiency Up To. BTU/WATT WAS WAS Right Side Control Panel WLS WLS Left Side Control Panel to Ton (,4 to, Btuh) Hz GREEN

More information

THE WALL-MOUNT GAS/ELECTRIC - WG-SERIES

THE WALL-MOUNT GAS/ELECTRIC - WG-SERIES THE WALL-MOUNT GASELECTRIC - WG-SERIES WG - SERIES to Ton 3, to 6, BTUH Capacity 1, to 1, BTUH Heating Input 6HZ The Bard Wall-Mount Electric Air Conditioner with gas fired heating is a self contained

More information

I-TEC TM I30H-I60H 2-Stage Compressor High Efficiency Air Source Heat Pumps

I-TEC TM I30H-I60H 2-Stage Compressor High Efficiency Air Source Heat Pumps I-TEC TM IH-IH 2-Stage Compressor High Efficiency Air Source Heat Pumps Cooling Capacities: 20,0 to 55,000 Btuh Heating Capacities: 20,200 to 54,500 Btuh The Bard I-TEC Indoor Heat Pump system is designed

More information

10 EER Units Air Conditioners (Standard RH) Page # 3 Air Conditioner Heat Kits (Standard RH) Page # 4

10 EER Units Air Conditioners (Standard RH) Page # 3 Air Conditioner Heat Kits (Standard RH) Page # 4 Units Air Conditioners (Standard RH) Page # 3 Air Conditioner Heat Kits (Standard RH) Page # 4 (Field Installed) Air Conditioners (Left Hand) Page # 6 Air Conditioner Heat Kits (Left Hand) Page # 7 (Field

More information

9 EER Units Air Conditioners (Standard RH) Page # 3 Air Conditioner Heat Kits (Standard RH) Page # 4

9 EER Units Air Conditioners (Standard RH) Page # 3 Air Conditioner Heat Kits (Standard RH) Page # 4 9 EER Units Air Conditioners (Standard RH) Page # 3 Air Conditioner Heat Kits (Standard RH) Page # 4 (Field Installed) Air Conditioners (Left Hand) Page # 6 Air Conditioner Heat Kits (Left Hand) Page #

More information

V High Efficiency Series

V High Efficiency Series UNIT DISCONNECT(S) BEHIND THIS PANAL Commercial HVAC V High Efficiency Series Wallmount Air Conditioners PERFORMANCE: Efficiency rating of 9.0/9.5 EER Electric heat available from 5 kw to 18 kw Designed

More information

REPLACEMENT PARTS MANUAL

REPLACEMENT PARTS MANUAL REPLACEMENT PARTS MANUAL WAA-C Wall-Mount Air Conditioner with 0- VFD-High Resistance Ground Kit NOTE: For installation guidance for the 0- kit, contact Bard Technical Services at () -0. Contents Description

More information

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS TECHNICAL SPECIFICATIONS S5BP Series Split System Air Conditioner 71/2 Ton Energy Star rated at 11.7 EER and 11.8 IEER 10 Ton rated at 11.2 EER and 11.5 IEER R-410A Refrigerant The S5BP Series of air conditioners

More information

Product Data. Features/Benefits. Omnizone 50XCA06-14 Air-Cooled Indoor Self-Contained Systems with Puron Refrigerant (R-410A) 5 to 12 Nominal Tons

Product Data. Features/Benefits. Omnizone 50XCA06-14 Air-Cooled Indoor Self-Contained Systems with Puron Refrigerant (R-410A) 5 to 12 Nominal Tons Product Data Omnizone 50XCA06-14 Air-Cooled Indoor Self-Contained Systems with Puron Refrigerant (R-410A) 5 to 1 Nominal Tons The 50XCA single-package cooling units with integral air-cooled condensers

More information

D M S 760 C01 A A 1 1

D M S 760 C01 A A 1 1 CONTENTS Description Features Options Available Selection Method Product Data Cooling Performance Data (85 F Ambient Cooling Performance Data (95 F Ambient) Cooling Performance Data (105 F Ambient)..............................

More information

Product Data. Features/Benefits. OMNIZONE 50XCR06-24 Remote Air-Cooled Indoor Self-Contained Systems with PURON Refrigerant (R-410A)

Product Data. Features/Benefits. OMNIZONE 50XCR06-24 Remote Air-Cooled Indoor Self-Contained Systems with PURON Refrigerant (R-410A) Product Data OMNIZONE 50XCR06-24 Remote Air-Cooled Indoor Self-Contained Systems with PURON Refrigerant (R-410A) 5 to 20 Nominal Tons The 50XCR single-package remote aircooled units offer: Compact, durable,

More information

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Single stage cooling capacity control on all 0 241 models Two stage cooling capacity control on

More information

REPLACEMENT PARTS MANUAL

REPLACEMENT PARTS MANUAL REPLACEMENT PARTS MANUAL W30H-A W30H-B W30H-C WALL MOUNTED PACKAGED HEAT PUMP W30HDA W30HDB W30HDC Models: W36H-A W36H-B W36H-C W36HDA W36HDB W36HDC General Notes Revised and/or additional pages may be

More information

CHP

CHP Packaged Unit Heat Pump CHP16-024-030-036-048-060 2-5 Ton Cooling 23,000-57,500 Btuh Heating 12,800-85,300 Btuh (5-25 kw) Optional Electric Heating FEATURES Designed for outdoor rooftop or ground level

More information

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS 50FP-1SB 50FP034, 038, 044, 048, 054, 064, 074 SINGLE-PACKAGE COOLING UNITS CONSTANT/VARIABLE VOLUME PRODUCT INTEGRATED CONTROLS CARRIER COMFORT NETWORK COMPATIBLE FACTORY-INSTALLED OPTIONAL ELECTRIC HEAT

More information

REPLACEMENT PARTS MANUAL

REPLACEMENT PARTS MANUAL REPLACEMENT PARTS MANUAL W4H-A W4H-B W4H-C WALL MOUNTED PACKAGED HEAT PUMPS W4HDA W4HDB W4HDC W4H-A W4H-B W4H-C Models: W4HDA W4HDB W4HDC W0H-A W0H-B W0H-C W0HDA W0HDB W0HDC General Notes Revised and/or

More information

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS Q6SD Series Single Packaged Heat Pump, Single Phase Q6SD-13 SEER, R-410A 2-5 Ton Units Cooling: 22,800 to 58,500 Btuh Heating: 22,800 to 58,500 Btuh The Q6 Series single packaged

More information

ELITE SERIES R-410A Ready - Multi-Position

ELITE SERIES R-410A Ready - Multi-Position PRODUCT SPECIFICATIONS AIR HANDLERS CBXM ELITE SERIES R-0A Ready - Multi-Position Bulletin No. 0 October 07 Supersedes June 0 Nominal Capacity -. to Tons Optional Electric Heat -. to 0 kw MODEL NUMBER

More information

PACKAGE AIR CONDITIONERS

PACKAGE AIR CONDITIONERS PACKAGE AIR CONDITIONERS FORM NO. S22-92 REV. 2 Supersedes Form No. S22-92 Rev. RLNA- SUPER HIGH EFFICIENCY SERIES NOMINAL SIZES -5 TONS [0.6-7.6 kw] *Unit shown with optional louver panels installed..0

More information

RCE13. Product Specifications. 13 SEER Electric / Electric Residential Packaged Unit. Refrigerant System. Cabinet Construction. Blower.

RCE13. Product Specifications. 13 SEER Electric / Electric Residential Packaged Unit. Refrigerant System. Cabinet Construction. Blower. RCE13 Product Specifications 13 SEER Electric / Electric Residential Packaged Unit Form No. RCE13-100 (04/2013) Refrigerant System Environmentally friendly R410A refrigerant Copper tubing with enhanced

More information

REPLACEMENT PARTS MANUAL

REPLACEMENT PARTS MANUAL REPLACEMENT PARTS MANUAL WALL MOUNTED PACKAGED AIR CONDITIONER Models: WAA-A WAA-A WAA-B WAA-C WAA-D WAA-F General Notes Revised and/or additional pages may be issued from time to time. A complete and

More information

S6BQ Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Split System 2-Stage Air Conditioner. 7 1/2 and 10 Ton rated at 11.2 EER and 12.

S6BQ Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Split System 2-Stage Air Conditioner. 7 1/2 and 10 Ton rated at 11.2 EER and 12. TECHNICAL SPECIFICATIONS S6BQ Series Split System 2-Stage Air Conditioner 7 1/2 and 10 Ton rated at 11.2 EER and 12.9 IEER The S6BQ Series of air conditioners offers exceptional performance. The unit,

More information

REPLACEMENT PARTS MANUAL

REPLACEMENT PARTS MANUAL REPLACEMENT PARTS MANUAL WALL MOUNTED PACKAGED AIR CONDITIONER Models: W1AA-A WAA-A WAA-B WAA-C WAA-D WAA-F General Notes Revised and/or additional pages may be issued from time to time. A complete and

More information

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: 036-21323-001-B-0202 GENERAL SPECIFICATIONS OUTDOOR UNIT: Two independent refrigerant circuits Inherently protected fan motors Two independent scroll compressors V-Coil Design Exterior service port connections

More information

PHR5. Product Specifications

PHR5. Product Specifications PHR5 Product Specifications UP to 15.5 SEER, UP to 12.5 EER, PACKAGE HEAT PUMP UNITS, 2 5 TONS 208/230 Volt, 1 phase, 60 Hz 208/230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally balanced R

More information

ERV ENERGY RECOVERY VENTILATOR 60 HZ. Indoor / Outdoor 500 to 10,000 cfm Capacity ERV I - D - D - P - 1 MODEL NUMBER IDENTIFICATION

ERV ENERGY RECOVERY VENTILATOR 60 HZ. Indoor / Outdoor 500 to 10,000 cfm Capacity ERV I - D - D - P - 1 MODEL NUMBER IDENTIFICATION P R O D U C T S P E C I F I C AT I O N S I N D O O R A I R Q U A L I T Y ERV ENERGY RECOVERY VENTILATOR 60 HZ Bulletin No. 20245 March 200 Supersedes April 2009 Indoor / Outdoor 500 to 0,000 cfm Capacity

More information

Contents. Control Panel. Control Panel. Blower Housing. Bard Manufacturing Company, Inc. Bryan, Ohio 43506

Contents. Control Panel. Control Panel. Blower Housing. Bard Manufacturing Company, Inc. Bryan, Ohio 43506 REPLACEMENT PARTS MANUAL WALL MOUNTED PACKAGE HEAT PUMPS Models: W4H W4HD W4H W4HD W0H W0HD General Notes Revised and/or additional pages may be issued from time to time. A complete and current manual

More information

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO technical sales guide - 60Hz Taurus R Ducted Split Units UPTO HIGH AMBIENT OPERATION 52 O C Page CONTENTS Nomenclature.. 2 Description. 3 Features.. 3 Product Data. 4 Condensing Unit Cooling Performance

More information

P6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Electric Cooling Units EER Commercial System Units

P6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Electric Cooling Units EER Commercial System Units TECHNICAL SPECIFICATIONS P6SP Series Rev A 6, 7½ and 10 Ton Packaged Electric Cooling Units 11.2 EER Commercial System Units These units are designed specifically for retrofit applications and compatibility

More information

Q6SE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase

Q6SE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS Q6SE Series Single Packaged Heat Pump, Single Phase Q6SE-14 SEER, 8.0 HSPF 2-5 Ton Units Cooling: 23,000 to 58,000 Btuh Heating: 22,800 to 59,000 Btuh The Q6 Series single packaged

More information

RPHP13. Product Specifications. 13 SEER Heat Pump Residential Packaged Unit. Refrigerant System. Cabinet Construction. Blower. Controls.

RPHP13. Product Specifications. 13 SEER Heat Pump Residential Packaged Unit. Refrigerant System. Cabinet Construction. Blower. Controls. RPHP13 Product Specifications Refrigerant System Environmentally friendly R410A refrigerant Copper tubing with enhanced fin coils External service gauge ports 13 SEER Heat Pump Residential Packaged Unit

More information

DESCRIPTION FEATURES

DESCRIPTION FEATURES SPLIT-SYSTEM AIR COOLED CONDENSING UNIT H5CE150, H5CE180 AND H5CE240 12-1/2, 15 AND 20 NOMINAL TONS (World 50Hz) DESCRIPTION These outdoor condensing units are completely assembled, piped and wired at

More information

M-SERIES MHP4 MODEL NUMBER GUIDE 3 M HP F P 1 ELECTRIC HEAT PUMP PACKAGED UNITS REVISION CODE

M-SERIES MHP4 MODEL NUMBER GUIDE 3 M HP F P 1 ELECTRIC HEAT PUMP PACKAGED UNITS REVISION CODE ELECTRIC HEAT PUMP PACKAGED UNITS MHP4 FORM NO. MHP4-100 (10/2018) MODEL NUMBER GUIDE 3 M HP 4 11 18 1 F P 1 FACTORY INSTALLED ELECTRIC HEAT 3= 3 KW 5 = 5 KW 7 = 7 KW 10 = 10 KW M = MAGIC-PAK HP = HEAT

More information

GPC14H. 2- to 5-Ton Packaged Air Conditioner 14 SEER. Cooling Capacity: 24,000-57,500 BTU/H

GPC14H. 2- to 5-Ton Packaged Air Conditioner 14 SEER. Cooling Capacity: 24,000-57,500 BTU/H H Cooling Capacity: 24,000-57,500 BTU/H 2- to 5-Ton Packaged Air Conditioner 14 SEER Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data... 4 Airflow Data... 16 Heater Kit Specifications...

More information

Models: W30A2, W36A2. Contents. Control Panel. Blower Assembly. Bard Manufacturing Company, Inc. Bryan, Ohio 43506

Models: W30A2, W36A2. Contents. Control Panel. Blower Assembly. Bard Manufacturing Company, Inc. Bryan, Ohio 43506 REPLACEMENT PARTS MANUAL WALL MOUNTED PACKAGE AIR CONDITIONER Models: W30A, W36A General Notes Revised and/or additional pages may be issued from time to time. A complete and current manual consists of

More information

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS 50Hz Single Package Rooftop, Cooling Only with Puronr (R---410A) Refrigerant One Stage Cooling Capacity Control: Size 07 Two Stage Cooling Capacity Control: Sizes 08, 09, 12 & 14 Submittal Data PERFORMANCE

More information

GQ6SD Series. Single Packaged Heat Pump 13 SEER, R-410A 2-5 Ton Units TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY

GQ6SD Series. Single Packaged Heat Pump 13 SEER, R-410A 2-5 Ton Units TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY TECHNICAL SPECIFICATIONS GQ6SD Series Single Packaged Heat Pump 13 SEER, R-410A 2-5 Ton Units The GQ6 Series single packaged units are high efficiency self contained cooling and heating units that can

More information

VT4BE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Heat Pump 14 SEER Residential System Ton Capacity WARRANTY

VT4BE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Heat Pump 14 SEER Residential System Ton Capacity WARRANTY TECHNICAL SPECIFICATIONS VT4BE Series R-410A High Efficiency Heat Pump 14 SEER Residential System 1.5 5 Ton Capacity The VT4BE Series now offers the choice of a heat pump that uses a more efficient and

More information

Tons BTU/h S.E.E.R* E.E.R** HSPF

Tons BTU/h S.E.E.R* E.E.R** HSPF SOUND REFRIGERANT ENVIRONMENTALLY PHD3 Product Specifications 13 SEER, R -410A PACKAGE HEAT PUMP, 2½ to 5 TONS 3 -Phase, 208/230-3 -60 and 460-3 -60 REFRIGERATION CIRCUIT R--410A refrigerant Copper tube/aluminum

More information

P6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioning, 13 SEER. 3, 4, 5 Ton Units

P6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioning, 13 SEER. 3, 4, 5 Ton Units TECHNICAL SPECIFICATIONS P6SD Series Single Packaged Air Conditioning, 13 SEER 3, 4, 5 Ton Units The P6 Series single packaged air conditioners are high efficiency self contained cooling units that can

More information

PCB COMMERCIAL SERIES

PCB COMMERCIAL SERIES PCB COMMERCIAL SERIES 50 Hz SELF-CONTAINED PACKAGE CONDITIONER 7½, 0, AND 5 TON [6.4 kw to 5.8 kw] COOLING CAPACITY: 90,000 TO 80,000 BTU/H The PCB Commercial 50 Hz self-contained packaged air conditioner

More information

13 SEER. Light Commercial 3 Phase Packaged Heat Pump. RHP13 Features and Benefits. Refrigerant System. Cabinet Construction. Blower.

13 SEER. Light Commercial 3 Phase Packaged Heat Pump. RHP13 Features and Benefits. Refrigerant System. Cabinet Construction. Blower. 13 SEER Light Commercial 3 Phase Packaged Heat Pump RHP13 Features and Benefits Form No. AC-RHP13-100 (05/2013) Refrigerant System Environmentally friendly R410A refrigerant Copper tubing with enhanced

More information

GP7RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner, Single Phase WARRANTY

GP7RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner, Single Phase WARRANTY TECHNICAL SPECIFICATIONS GP7RD Series Single Packaged Air Conditioner, Single Phase GP7RD 13 SEER, R-410A 2 thru 4 Ton Units Cooling: 24,000 to 47,000 Btuh The GP7 Series single packaged air conditioners

More information

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINTS

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINTS 50FN-1SB 50FNX,FNY078,088,104 SINGLE-PACKAGE COOLING UNITS CONSTANT/VARIABLE AIR VOLUME PRODUCT INTEGRATED CONTROLS CARRIER COMFORT NETWORK COMPATIBLE WITH INTEGRAL ECONOMIZER AND HIGH-CAPACITY MODULATING

More information

S3BN Series Split System Air Conditioner 10.3 EER Commercial System 7½ and 10 Ton Capacity R-22 Refrigerant

S3BN Series Split System Air Conditioner 10.3 EER Commercial System 7½ and 10 Ton Capacity R-22 Refrigerant TECHNICAL SPECIFICATIONS S3BN Series Split System Air Conditioner 10.3 EER Commercial System 7½ and 10 Ton Capacity R-22 Refrigerant The S3BN Series of air conditioners offers exceptional performance from

More information

AFGP12B. Features. Efficiency: 12 SEER 80% AFUE. Warranty: 10-year limited compressor 10-year limited heat exchanger 5-year limited components

AFGP12B. Features. Efficiency: 12 SEER 80% AFUE. Warranty: 10-year limited compressor 10-year limited heat exchanger 5-year limited components AFGP12B Gas/Electric Package Unit Features Shipped for horizontal applications; easily converted to downshot Side-by-side horizontal discharge Standard thermostatic expansion valve Crimp-Tite weld-free

More information

Product Data. Features/Benefits 50JS SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS)

Product Data. Features/Benefits 50JS SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS) SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS) Product Data UNIT (50 Hz) Single-packaged Heat Pump for Residential and Light Commercial applications. Features/Benefits One-piece

More information

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS FEATURES DESCRIPTION. H5CE090 & H3CE AND 10 NOMINAL TONS (World 50HZ)

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS FEATURES DESCRIPTION. H5CE090 & H3CE AND 10 NOMINAL TONS (World 50HZ) 550.39-TG1YI (994) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS H5CE090 & H3CE120 7.5 AND 10 NOMINAL TONS (World 50HZ) HCE090 SUNLINE 2000 DESCRIPTION These Sunline 2000 units are completely assembled, piped

More information

CAS. Product Specifications

CAS. Product Specifications CAS Product Specifications COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Single stage cooling capacity control on all 0 to 241 models Two stage

More information

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11. TECHNICAL SPECIFICATIONS Q6SP Series Rev A 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.0 EER Commercial Systems Meet or Exceed ASHRAE 90.1-2010 These 7½ and 10 ton units are designed

More information

Q6SP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

Q6SP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11. TECHNICAL SPECIFICATIONS Q6SP Series 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.0 EER Commercial Systems Meet or Exceed ASHRAE 90.1 These 7½ and 10 ton units are designed specifically

More information

Q6SD Series 13 SEER, Three Phase, Packaged Heat Pump with R-410A 3-5 Ton Units

Q6SD Series 13 SEER, Three Phase, Packaged Heat Pump with R-410A 3-5 Ton Units TM TECHNICAL SPECIFICATIONS Q6SD Series 13 SEER, Three Phase, Packaged Heat Pump with R-410A 3-5 Ton Units The Q6SD Series packaged units are high efficiency self contained cooling and heating units that

More information

WALL MOUNTED PACKAGE AIR CONDITIONER REPLACEMENT PARTS MANUAL. Models: WA381 WA424D WA423 WA485D WA484 WA491 WA602 WA605 WA605D.

WALL MOUNTED PACKAGE AIR CONDITIONER REPLACEMENT PARTS MANUAL. Models: WA381 WA424D WA423 WA485D WA484 WA491 WA602 WA605 WA605D. REPLACEMENT PART MANUAL WALL MOUNTED PACKAGE AIR CONDITIONER Models: WA WA44D WA4 WA4D WA44 WA49 WA0 WA0 WA0D General Notes Contents Revised and/or additional pages may be issued from time to time. A complete

More information

DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS D(CE, CG) 036, 048, 060 & YTG-A-0207

DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS D(CE, CG) 036, 048, 060 & YTG-A-0207 TECHNICAL GUIDE SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS D(CE, CG) 036, 048, 060 & 072 3, 4, 5 & 6 NOMINAL TONS 10.0 SEER (3, 4, & 5 Ton), 9.0 EER (6 Ton) DESCRIPTION YORK

More information

A I R H A N D L E R S CB26UH-R. MERIT Series R-22 - Upflow / Horizontal P R O D U C T S P E C I F I C AT I O N S

A I R H A N D L E R S CB26UH-R. MERIT Series R-22 - Upflow / Horizontal P R O D U C T S P E C I F I C AT I O N S P R O D U C T S P E C I F I C AT I O N S A I R H A N D L E R S CB6UH-R MERIT Series R- - Upflow / Horizontal Bulletin No. 1067 April 01 Supersedes January 01 Nominal Capacity - 1.5 to 5 Tons Optional Electric

More information

R6GD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, Three Phase, Packaged Gas/ Electric Units with R-410A 3-5 Ton Units WARRANTY

R6GD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, Three Phase, Packaged Gas/ Electric Units with R-410A 3-5 Ton Units WARRANTY TECHNICAL SPECIFICATIONS R6GD Series 13 SEER, Three Phase, Packaged Gas/ Electric Units with R-410A 3-5 Ton Units The R6GD Series packaged gas/electrics are high efficiency self contained cooling units

More information

GV Series High Efficiency Geothermal/Water Source Packaged Step-Capacity Heat Pump R-410A

GV Series High Efficiency Geothermal/Water Source Packaged Step-Capacity Heat Pump R-410A GV Series High Efficiency Geothermal/Water Source Packaged Step- Heat Pump R-410A Ground Water Application: Water Temp 45 to 75 Ground Loop Application: Temp Range to GV Series Geothermal/Water Source

More information

TECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW

TECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW MODELS: D4HH 024 THRU 180 York horizontal ductable air conditioning packages offer a complete line of

More information

JT4BE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Heat Pump 14 SEER Residential System Ton Capacity WARRANTY

JT4BE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Heat Pump 14 SEER Residential System Ton Capacity WARRANTY TECHNICAL SPECIFICATIONS JT4BE Series R-410A High Efficiency Heat Pump 14 SEER Residential System 1.5 5 Ton Capacity The JT4BE Series now offers the choice of a heat pump that uses a more efficient and

More information

REPLACEMENT PARTS MANUAL

REPLACEMENT PARTS MANUAL REPLACEMENT PARTS MANUAL WALL MOUNTED PACKAGED HEAT PUMP Models: W18H-A W4H-A W4H-B W4H-C W4HDA W4HDB W4HDC General Notes Revised and/or additional pages may be issued from time to time. A complete and

More information

48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH

48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH 48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled or Hot Water with Optional Electric Heat Multi-Position

More information

SUNLINE 2000 (WORLD 50 HZ)

SUNLINE 2000 (WORLD 50 HZ) 530.26-TG1YI (298) SINGLE PACKAGE AIR-COOLED AIR CONDITIONERS D3CE 036, 048, 060 & 076 D5CG 036, 048, 060 & 076 3, 4, 5 AND 6 NOMINAL TONS SHOWN SUNLINE 2000 (WORLD 50 HZ) DESCRIPTION YORK Sunline 2000

More information

S/T Ratio. Input BTU/h

S/T Ratio. Input BTU/h SOUND REFRIGERANT ENVIRONMENTALLY PGD3 Product Specifications 13 SEER PACKAGE GAS / ELECTRIC UNIT, 2½ to 5 TONS 3 Phase, 208/230 3 60 and 460 3 60 REFRIGERATION CIRCUIT Environmentally sound R-410A refrigerant

More information

Bosch BOVA Split System Heat Pump

Bosch BOVA Split System Heat Pump Bosch BOVA Split System Heat Pump Condensing Units Up to 18 SEER 2-3-4-5 Ton Capacity R410A Product Specifications 2 Bosch IDS BOVA Product Specifications Data subject to change 03.2018 Bosch Thermotechnology

More information

JT4BD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Heat Pump 13 SEER Residential System Ton Capacity WARRANTY

JT4BD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Heat Pump 13 SEER Residential System Ton Capacity WARRANTY TECHNICAL SPECIFICATIONS JT4BD Series R-410A High Efficiency Heat Pump 13 SEER Residential System 1.5 5 Ton Capacity The JT4BD Series now offers the choice of a heat pump that uses a more efficient and

More information

ZHA/ZHB SERIES WARNING

ZHA/ZHB SERIES WARNING Service Literature Corp. 09-L Revised 7-08 ZHA/ZHB SERIES, 4, 5 and 6 ton 0.6 to kw ZHA/ZHB06, 048, 060, 07 The ZHA/ZHB packaged electric heat pump units are available in standard cooling efficiency (06S,

More information

REPLACEMENT PARTS MANUAL

REPLACEMENT PARTS MANUAL REPLACEMENT PARTS MANUAL WALL MOUNTED PACKAGED AIR CONDITIONER Models: WLB-A WLB-A WLB-B WLB-F General Notes Revised and/or additional pages may be issued from time to time. A complete and current manual

More information

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H4CE090 & H2CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H4CE090 & H2CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS 550.23-TG1Y (595) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS H4CE090 & H2CE120 & H1CE150 7-1/2, 10, & 12-1/2 NOMINAL TONS 8.9-9.5 EER SUNLINE 2000 HCE090 208/230/460 VOLT ONLY 208/230/575 VOLT ONLY DESCRIPTION

More information

13 SEER Light Commercial 3 Phase

13 SEER Light Commercial 3 Phase 13 SEER Light Commercial 3 Phase Packaged Gas / Electric RGE13 Features and Benefits Form No. AC-RGE13-100 (04/2013) Refrigerant System Environmentally friendly R410A refrigerant Copper tubing with enhanced

More information

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ DESCRIPTION FEATURES

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ DESCRIPTION FEATURES (791) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ H1CE180 & 240 15 AND 20 NOMINAL TONS (60 HZ) 13 AND 17-1/2 NOMINAL TONS (50 HZ) SUNLINE 2000 DESCRIPTION These Sunline 2000 units are completely

More information

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS 550.13-TG1Y(98) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS HCA300, 360, 80 & 600 5 THRU 50 NOMINAL TONS HCA80 DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece

More information

14 SEER R -410A PACKAGE GAS / ELECTRIC UNIT 2 to 5 TON

14 SEER R -410A PACKAGE GAS / ELECTRIC UNIT 2 to 5 TON 14 SEER R -410A PACKAGE GAS / ELECTRIC UNIT 2 to 5 TON Two -Stage Gas Heating/Two -Stage Electric Cooling REFRIGERATION CIRCUIT All models are equipped with high efficiency two--stage Copeland UltraTech

More information

N4A6. Product Specifications

N4A6. Product Specifications ENVIRONMENTALLY SOUND REFRIGERANT N4A6 Product Specifications EFFICIENT UP TO 16.5 SEER/12.2 13.0 EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208/2 Volt,

More information

Bosch BOVA Split System Heat Pump

Bosch BOVA Split System Heat Pump Bosch BOVA Split System Heat Pump Condensing Units Up to 18 SEER 2-3-4-5 Ton Capacity R410A Product Specifications 2 Bosch IDS BOVA Product Specifications Data subject to change 06.2016 Bosch Thermotechnology

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model PSA4BG Series M1200 Product Line Ultra High Efficiency Air Conditioner 20 SEER Residential System 2-5 Ton Capacities 2 The iq Drive air conditioner system features modulating

More information

GPC14H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER

GPC14H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER Cooling Capacity: 24,000-57,500 BTU/H H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data... 5 Airflow Data... 18 Heater Kit

More information

CPC Series. Submittal Data Form. 15- & 20-Ton Self-Contained. Packaged Air Conditioner. with R-410A

CPC Series. Submittal Data Form. 15- & 20-Ton Self-Contained. Packaged Air Conditioner. with R-410A CPC Series 15- & 20-Ton Self-Contained Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: Packaged Air Conditioner with R-410A

More information

R6GD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, Three Phase, Packaged Gas/Electric Units 3-5 Ton Units

R6GD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, Three Phase, Packaged Gas/Electric Units 3-5 Ton Units TECHNICAL SPECIFICATIONS R6GD Series 13 SEER, Three Phase, Packaged Gas/Electric Units 3-5 Ton Units The R6GD Series packaged gas/electrics are high efficiency self contained heating and cooling units

More information

Operating Net Capacity BTU/h. Input BTU/h Efficiency. lbs (kg) PGR524040KGP* 23, ,000/26, /8 x 47 x 31-7/16

Operating Net Capacity BTU/h. Input BTU/h Efficiency. lbs (kg) PGR524040KGP* 23, ,000/26, /8 x 47 x 31-7/16 SOUND REFRIGERANT ENVIRONMENTALLY Product Specifications UP to 16 SEER, UP to 12.5 EER, PACKAGE GAS / ELECTRIC, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz 208/230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT

More information

EFFICIENCY 17 SEER TWO STAGE AIR CONDITIONER WITH OBSERVER

EFFICIENCY 17 SEER TWO STAGE AIR CONDITIONER WITH OBSERVER ENVIRONMENTALLY SOUND REFRIGERANT HCA7 QuietComfort DXT+ Product Specifications HIGH EFFICIENCY 17 SEER TWO STAGE AIR CONDITIONER WITH OBSERVER COMMUNICATING CONTROL SYSTEM 2 THRU 5 TONS SPLIT SYSTEM 208/230

More information

R6GN Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Gas/Electric Units with R-410A WARRANTY

R6GN Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Gas/Electric Units with R-410A WARRANTY TECHNICAL SPECIFICATIONS R6GN Series Single Packaged Gas/Electric Units with R-410A R6GN 10.8 EER Commercial System 12½ and 15 Ton Units These units offer flexibility in the replacement market. The 12½

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TM TECHNICAL SPECIFICATIONS Model P6SD Series M120 Product Line Single Packaged Air Conditioning, 13 SEER - R-410A, 3, 4 and 5 Ton Units 12 YEAR ALL PARTS WARRANTY This product offers a 1 Year Dependability

More information

N2AE - 50 Hz PRODUCT SPECIFICATIONS

N2AE - 50 Hz PRODUCT SPECIFICATIONS ISO 9001:2000 REGISTERED N2AE - 50 Hz PRODUCT SPECIFICATIONS 50 Hz AIR CONDITIONING CONDENSING UNIT 230 Volt, 1-phase, 50 Hz in 1½, 2, 2½, 3, 4 tons 400 Volt, 3-phase, 50 Hz in 3, 3½, 4, 5 tons REFRIGERATION

More information

GT Series High Efficiency Geothermal/Water Source Step-Capacity Heat Pump R-410A

GT Series High Efficiency Geothermal/Water Source Step-Capacity Heat Pump R-410A Ground Water Application: Water Temp 45 to 75 Ground Loop Application: Temp Range to GT Series High Efficiency Geothermal/Water Source Step- Heat Pump R-410A The GT Series Geothermal/Water Source Heat

More information

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units 11.0 EER

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units 11.0 EER TECHNICAL SPECIFICATIONS Q6SP Series Rev A 7.5 and 10 Ton Packaged Electric Heat Pump Units 11.0 EER Commercial Systems Meet or Exceed ASHRAE 90.1-2010 These 7½ and 10 ton units are designed specifically

More information

CPC Commercial. 15- & 20-Ton, Three-Phase Packaged Air Conditioner. 20-Ton Cooling Capacity: 240,000 BTU/h

CPC Commercial. 15- & 20-Ton, Three-Phase Packaged Air Conditioner. 20-Ton Cooling Capacity: 240,000 BTU/h CPC Commercial 15- & 20-Ton, Three-Phase Packaged Air Conditioner 15-Ton Cooling Capacity: 180,000 BTU/h 20-Ton Cooling Capacity: 240,000 BTU/h Contents Nomenclature...2 Product Features...3 Product Specifications...4

More information

P6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

P6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS TECHNICAL SPECIFICATIONS P6SD Series The P6SD Series packaged units are high efficiency self contained cooling units that can be installed on a roof or on a slab. The convertible unit design makes installations

More information

CONVERTIBLE SINGLE PACKAGE HEAT PUMP

CONVERTIBLE SINGLE PACKAGE HEAT PUMP PHA D SERIES UNITARY AIRCONDITIONING MANUFACTURER CERTIFIED TO ARI AS COMPLYING WITH ARI EQUIPMENT STANDARD 210 CONVERTIBLE SINGLE PACKAGE HEAT PUMP FEATURE SINGLE PACKAGE, 2 THRU 5 TON COOLING Single

More information

Geo-Trio High Efficiency Geothermal/Water Source Step-Capacity Heat Pump R-410A

Geo-Trio High Efficiency Geothermal/Water Source Step-Capacity Heat Pump R-410A Geo-Trio High Efficiency Geothermal/Water Source Step- Heat Pump R-410A Ground Water Application: Water Temp to Ground Loop Application: Temp Range to The Bard Geo-Trio Geothermal/Water Source Heat Pump

More information

GP5RD Series. Single Packaged Air Conditioner, Single Phase TECHNICAL SPECIFICATIONS

GP5RD Series. Single Packaged Air Conditioner, Single Phase TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS GP5RD Series Single Packaged Air Conditioner, Single Phase GP5RD-13 SEER, R-410A 2 thru 5 Ton Units Cooling: 24,000 to 60,000 Btuh The GP5 Series single packaged air conditioners

More information

R4A5. Product Specifications EFFICIENT 14 SEER/ EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT

R4A5. Product Specifications EFFICIENT 14 SEER/ EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT ENVIRONMENTALLY SOUND REFRIGERANT R4A5 Product Specifications EFFICIENT 14 SEER/11.7 12.2 EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt, 1 phase,

More information

TSA6. Product Specifications. SmartComfort TXC 5600

TSA6. Product Specifications. SmartComfort TXC 5600 ENVIRONMENTALLY SOUND REFRIGERANT TSA6 SmartComfort TXC 5600 Product Specifications 16 SEER SINGLE STAGE AIR CONDITIONER WITH OBSERVER COMMUNICATING CONTROL SYSTEM 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230

More information