THE WALL-MOUNT STEP CAPACITY HEAT PUMPS Integrated Part Load Value (IPLV) Efficiency Up To 15.0 BTU/WATT

Size: px
Start display at page:

Download "THE WALL-MOUNT STEP CAPACITY HEAT PUMPS Integrated Part Load Value (IPLV) Efficiency Up To 15.0 BTU/WATT"

Transcription

1 THE WALL-MOUNT STEP CAPACITY HEAT PUMPS Integrated Part Load Value (IPLV) Efficiency Up To 5.0 BTU/WATT Green Refrigerant R-4A Models: C24H to C0H Up to.0 EER Cooling Capacities: 22,200 to 55,0 BTUH Heating Capacities:,200 to 5,000 BTUH Quiet Climate Flex The Bard Wall-Mount Heat Pump is a self-contained energy efficient heating and cooling system, which is designed to offer maximum indoor comfort at a minimal cost without using valuable indoor floor space or outside ground space. This unit is the ideal product for versatile applications such as: new construction, modular offices, school modernization, and the like. Factory or field installed accessories are available to meet specific job requirements. CH Series Special Features ECM Indoor Blower Motor: Features a variable speed motor providing super-high efficiency, low sound levels & soft-start capabilities. The motor is selfadjusting to provide the proper airflow rate for the staged capacity, and for higher static pressure in ducted installations without user adjustment or wiring changes. Step Capacity : Scroll 2-Stage s are standard on all 2 to 5 ton models. Eliminates need for crankcase heater. Double isolated floating compressor mounting system, compressor sound blanket, and discharge line muffler for reduced sound level. Quiet Curb Options: Various curbs are specially designed for the CH product family that reduce sound levels for school and occupied building applications. Draw-Thru Condenser Airflow: Condenser air is brought in from the front of the unit condenser section, and exhausted through the side grilles. This allows quiet operation, and avoids heat pump defrost water accumulation in front of the CH unit. Engineered Features Copper Tube/Aluminum Fin Coils: Grooved copper tubing and enhanced aluminum fins provide maximum heat transfer and high energy efficiency. Optional phenoliccoated coils are also available. Twin Blowers: Move air quietly. All models feature variable speed blower motors providing airflow adjustment for high and low static operation. Motor overload protection is standard on all models. Phase Rotation Monitor: on all 3 phase scroll compressors. Protects against reverse rotation if power supply is not properly connected. R-4A Refrigerant: Designed with R-4A (HFC) non-ozone depleting refrigerant in compliance with the Montreal protocol and 20 EPA requirements. Liquid Line Filter Drier: on all units. Protects system against moisture. Foil Faced Insulation: on all units. Galvanized 20 Gauge Zinc Coated Cabinet: Cleaned, rinsed, sealed and dried before the polyurethane primer is applied. The cabinet is handsomely finished with a baked on, beige textured enamel, which allows it to withstand 00 hours of salt spray tests per ASTM B7-03. Stainless Steel cabinets available. Electrical Components: Are easily accessible for routine inspection and maintenance through a right side, service panel opening. Features a lockable, hinged access cover to the circuit breaker or rotary disconnect switch. Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages are factory or field installed for all 2 through 5 ton models. Features easy slide-in field assembly with various BTUH outputs. Condenser Fan and Motor Shroud Assembly: Slide out for easy access. Filter Service Door: Separate service door provides easy access for filter change. One Inch, Disposable Air Filters: Are standard equipment. Filter rack permits the addition of 2" pleated filter. Factory or field installed. Solid State Electronic Heat Pump Control: Provides efficient 30, 0 or 0 minute defrost cycle. A thermistor sensor, speed up terminal for service and minute defrost override are standard on the electronic heat pump control. High & Low Pressure Switches are Auto- Reset: on all units. Built-in lockout circuit resets from the room thermostat. Provides commercial quality protection to the compressor. Five Minute Time Delay: Short cycle protection is standard. Built into the heat pump control. Built-in Circuit Breakers: on all electric heat versions of single (230/20 volt) and three phase (230/20 volt) equipment. Rotary disconnects are standard on three phase (40 volt) equipment. 40V circuit breaker Model C42H shown with TCURBF30 Wall Curb Attached Quiet Curb Option must be added to obtain Quiet Climate Flex sound ratings. available as option on 0KW only. Slope Top: feature for water run-off. Full Length Mounting Brackets: Built into cabinet for improved appearance and easy installation. NOTE: Bottom mounting bracket included to assist in installation. Top Rain Flashing: feature on all models. Outdoor Coil Drain Pan: built in feature Drain Connnection Kit is standard (recommended for non-freezing climates only). Bard is an ISO 00:200 Certified Manufacturer Form No. S Supersedes S345-3 Page of 24

2 Certified Capacity and Efficiency Ratings at at Full Full Capacity MODELS C24H C30H C3H C42H C4H C0H Cooling BTUH, Stage 2 (Full Capacity) j 0/7-5 EER jk Rated CFM Certified in accordance with ARI for single package vertical units EER = Energy Efficiency Ratio - BTU/WATT efficiency Integrated Part Load Value - BTU/WATT efficiency (combines Stage & 2 performance) COP = Coefficient of Performance - BTU/WATT efficiency Capacity and Efficiency Ratings at Partial Capacity Specifications 2-/2 through 3 Ton Specifications 3-/2 through 5 Ton 22, IPLV (Integrated Stage and Stage 2) jl 0/ High Temperature 47 Heating BTUH, Stage 2 (Full Capacity) COP jm Rated CFM, MODELS C24H C30H C3H C42H C4H C0H Cooling BTUH, Stage (Partial Capacity) 0/7-0 Part Load (0/7-0) Stage Cooling Operating CFM High Temperature Heating 47 BTUH, Stage (Partial Capacity) Operating CFM 7, , , , , ,00 35, , , , , , , , , , , , ,0. 5, , , MODELS C24H-A C24H-B C30H-A C30H-B C30H-C C3H-A C3H-B C3H-C Electrical Rating--0 Hz 230/20-230/ /20-230/ /20-230/ Operating Voltage Range Circuit A Voltage 203/20 230/ /20 230/ /20 230/20 40 Rated Load Amps 7.5 / / / / / /. 5.0 Branch Circuit Selection Current Lock Rotor Amps 5.3 / / / 73 5 / / 3 73 / 73 3 Type Scroll Scroll --- Scroll Scroll Scroll Scroll Scroll Scroll Fan Motor & Condenser Fan Motor--HP-RPM-SPD /5-- / /5-- /5-- /5-- / / / Fan Motor--Amps Fan--DIA/CFM 20"-00 20" "-00 20"-00 20"-00 24" " "-200 Blower Motor & Evap. Blower Motor--HP-RPM-SPD /3 Var. /3 Var. --- /3 Var. /3 Var. /3 Var. /2 Var. /2 Var. /2 Var. Blower Motor--Amps CFM w/filter j Filter Sizes (inches) STD. x 30 x x 30 x --- x 30 x x 30 x x 30 x 20 x 30 x 20 x 30 x 20 x 30 x Basic Unit Weight-LBS Blank-Off Plate Commercial Room Ventilator Economizer Energy Recovery Ventilator MODELS C42H-A C42H-B C42H-C C4H-A C4H-B C4H-C C0H-A C0H-B C0H-C Electrical Rating--0 Hz 230/20-230/ /20-230/ /20-230/ Operating Voltage Range Circuit A Voltage 230/20 230/ /20 230/ /20 230/20 40 Rated Load Amps 4.0 / 5..2 / /.2. / / / Branch Circuit Selection Current Lock Rotor Amps / / / / 53 / 52 Type Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll Fan Motor & Condenser Fan Motor--HP-RPM-SPD / / /3-25- / / /3-25- /2-25- /2-25- /2-25- Fan Motor--Amps Fan--DIA/CFM 24" " " " " " " " "-3700 Blower Motor & Evap. Blower Motor--HP-RPM-SPD 3/4 Var. 3/4 Var. 3/4 Var. 3/4 Var. 3/4 Var. 3/4 Var. 3/4 Var. 3/4 Var. 3/4 Var. Blower Motor--Amps CFM w/filter j Filter Sizes (inches) STD. 20 x 30 x 20 x 30 x 20 x 30 x 20 x 30 x 20 x 30 x 20 x 30 x 20 x 30 x 20 x 30 x 20 x 30 x Basic Unit Weight-LBS Blank-Off Plate Commercial Room Ventilator Economizer Energy Recovery Ventilator Form No. S Supersedes S345-3 Page 2 of 24 See Curb Weights - Page

3 Ventilation System Packages Bard Wall-Mounts are designed to provide optional ventilation packages to meet all of your ventilation and indoor air quality requirements. All units are equipped with a barometric fresh air damper as the standard ventilation package. All ventilation packages can be built-in at the factory, or field-installed at a later date. BLANK OFF PLATE - BOP OPTIONAL A blank off plate is installed on the inside of the service door. It covers the air inlet openings which restricts any outside air from entering into the unit. The blank off plate should be utilized in applications where outside air is not required to be mixed with the conditioned air. Commercial Room Ventilator MIS-33 COMMERCIAL ROOM VENTILATOR - CHCRV NOTE: Models C24H & C30H with CHCRV-3 require a Wall Curb Model TCURBF2430 or TCURBT2430 (See Page ) OPTIONAL The built-in commercial room ventilator is internally mounted behind the service door and allows outside ventilation air, up to % of the total airflow rating of the unit, to be introduced through the air inlet openings. It includes a built-in exhaust air damper. The commercial room ventilator (CRV) is a simple and innovative approach to improving the indoor air quality by providing fresh air intake and exhaust capability through the CRV. The damper can be easily adjusted to control the amount of fresh air supplied into the building. The CRV can be controlled by indoor blower operation or field controlled based on room occupancy. The CRV is modulating design with power open - spring return on power loss. Complies with ANSI/ASHRAE 2. Ventilation for Acceptable Indoor Air Quality. Economizer MIS-33 ECONOMIZER - ECONCHS All economizers require matching TCURBF or TCURBT (See Page ) OPTIONAL The built-in economizer system is internally mounted behind the service door and allows outdoor air to be introduced through the air inlet openings. The amount of outdoor air varies in response to the system controls and settings defined by the end user. It includes a built-in exhaust air damper. The economizer is designed to provide free cooling when outside air conditions are cool and dry enough to satisfy cooling requirements without running the compressor. This in turn provides lower operating costs, while extending the life of the compressor. Features: Designed to deliver 75% of cooling rated CFM when equipped with standard 3" air intake hood Honeywell Drive Hi-Torque Actuator Positive shut-off with non-stick gaskets Electronic sensors, Enthalpy used for outdoor free cooling decision Honeywell JADE electronic economizer module with precision settings and diagnostics Energy Recovery Ventilator MIS-375 WALL-MOUNT ENERGY RECOVERY VENTILATOR - CHERV OPTIONAL The wall-mount energy recovery ventilator (ERV) is a highly innovative approach to meeting indoor air quality ventilation requirements as established by ANSI/ASHRAE 2.. The ERV allows from 200 to 4 CFM (depending upon model) of fresh air and exhaust through the unit while maintaining superior indoor comfort and humidity levels. In most cases this can be accomplished without increasing equipment sizing or operating costs. Heat transfer efficiency is up to 7% during summer and 75% during winter conditions. The ERV consists of a unique rotary energy recovery cassette that provides effective sensible and latent heat transfer capabilities during summer and winter conditions. Various control schemes are addressed including limiting ventilation during building occupancy only. The ERV is designed to be internally mounted behind the service door in the WA, WH or WL model wall-mount units. It can be built-in at the factory or field installed as an option. CHERV-*3 and CHERV-*5 can be independently adjusted for intake and exhaust rates. 3" air intake hood is standard. CHERV Model ERV s have exhaust gravity shut-off dampers all sizes. CHERV-A5 & -C5 have motorized air intake damper. DRAW-THRU CONDENSER AIRFLOW The CH unit requires the use of a curb to meet the Quietflex sound ratings. Due to draw-thru air pressurizing the condenser section, room exhaust air exits the bottom of the curb. These special wall curbs allow for the exhaust air to pass through the bottom of the curb instead of through the condenser section of the CH unit. The following vent options require the use of a wall curb: CHCRV-3 ECONCHS-E3 ECONCHS-E5 Refer to the "C**H Unit to Wall Curb Application Guide" (Page ) for curb selection options when using the vent options listed above. Complies with efficiency requirements of ASHRAE/IESNA Certified to ANSI/ARI for SPVU (Single Package Vertical Units). Intertek ETL Listed to for Safety Heating and Cooling Equipment ANSI/UL 5/CSA 22.2 No , Fourth Edition. Commercial Product - Not intended for Residential application. Form No. S Supersedes S345-3 Page 3 of 24

4 Modulating Commercial Room Ventilator Performance Data : CHCRV-3 for C24H 700 C24H Vent Airflow 00 0 Airflow (CFM) C24H Stage C24H Blower Only Vent Blade Position Airflow amounts less than 0 CFM may not be achievable. Modulating Commercial Room Ventilator Performance Data : CHCRV-3 for C30H C30H Vent Airflow Airflow (CFM) C30H Stage C30H Blower Only Vent Blade Position Form No. S Supersedes S345-3 Page 4 of 24 Airflow amounts less than 0 CFM may not be achievable.

5 Commercial Room Ventilator Performance Data : CHCRV-5 for C3H & C42H 00 C3H and C42H Vent Airflow Airflow (CFM) C42H and C3H Stage 2 C42H Stage C42H and C3H Blower Only, C3H Stage Vent Blade Position Airflow amounts less than 0 CFM may not be achievable. Commercial Room Ventilator Performance Data : CHCRV-5 for C4H & C0H 400 C4H and C0H Vent Airflow Airflow (CFM) C0H Stage 2 C0H Stage C4H Stage2 C4H Stage C4 & C0 Blower Only Vent Blade Position Airflow amounts less than 0 CFM may not be achievable. Form No. S Supersedes S345-3 Page 5 of 24

6 Form No. S Supersedes S345-3 Page of 24 This page intentionally left blank

7 Performance and Application Data - CHERV-*3 (C24H & C30H) Ambient O.D. DB/ WB VENTILATION RATE 400 CFM 3% EFFICIENCY SUMMER COOLING PERFORMANCE (INDOOR DESIGN CONDITIONS 75 DB / 2 WB) VENTILATION RATE 325 CFM 4% EFFICIENCY VENTILATION RATE 2 CFM 5% EFFICIENCY F VLT VLS VLL HRT HRS HRL VLT VLS VLL HRT HRS HRL VLT VLS VLL HRT HRS HRL CHERV- 3 WINTER HEATING PERFORMANCE (INDOOR DESIGN CONDITIONS 70 DB) Ambient O.D. 400 CFM 75% EFF. VENTILATION RATE 325 CFM 7% EFF. 2 CFM 77% EFF DB/ F WVL WHR WVL WHR WVL WHR LEGEND: VLT = Ventilation Load - Total VLS = Ventilation Load - Sensible VLL = Ventilation Load - Latent HRT = Heat Recovery - Total HRS = Heat Recovery - Sensible HRL = Heat Recovery - Latent WVL = Winter Ventilation Load WHR = Winter Heat Recovery NOTE: Sensible performance only is shown for winter application. Form No. S Supersedes S345-3 Page 7 of 24

8 Performance and Application Data - CHERV-*5 (C3H, C42H, C4H & C0H) SUMMER COOLING PERFORMANCE (INDOOR DESIGN CONDITIONS 75 DB / 2 WB) Ambient O.D. VENTILATION RATE 4 CFM VENTILATION RATE 375 CFM VENTILATION RATE 300 CFM DB/ WB F VLT VLS VLL HRT HRS HRL VLT VLS VLL HRT HRS HRL VLT VLS VLL HRT HRS HRL CHERV- 5 WINTER HEATING PERFORMANCE (INDOOR DESIGN CONDITIONS 70 DB) Ambient O.D. VENTILATION RATE 4 CFM 375 CFM 300 CFM DB/ F WVL WHR WVL WHR WVL WHR LEGEND: VLT = Ventilation Load - Total VLS = Ventilation Load - Sensible VLL = Ventilation Load - Latent HRT = Heat Recovery - Total HRS = Heat Recovery - Sensible HRL = Heat Recovery - Latent WVL = Winter Ventilation Load WHR = Winter Heat Recovery Form No. S Supersedes S345-3 Page of 24 NOTE: Sensible performance only is shown for winter application.

9 Electrical Specifications Heat Pumps Model Rated Volts & Phase C24H-A0Z -A04 230/ AS -AF No. Field Power Circuits or 2 j Minimum Circuit Ampacity Single Circuit k Max. External Fuse or Ckt. Brkr l Field Power Wire Size l Ground Wire j Minimum Circuit Ampacity k Max. Circuit Exterior Fuse or Ckt. Brkr. Multiple Circuit l Field Power Wire Size l Ground Wire Ckt. A Ckt. B Ckt. C Ckt. A Ckt. B Ckt. C Ckt. A Ckt. B Ckt. C Ckt. A Ckt. B Ckt. C C24H-B0Z -B0 230/ B C30H-A0Z -A04 230/ AS -AF or C30H-B0Z -B0 230/ B NOTE A C30H-C0Z/C0C -C0 -C C3H-A0Z -A05 230/ A -A5 or 2 or C3H-B0Z -B0 230/ B0 -B NOTE A C3H-C0Z/C0C -C0 -C0 -C C42H-A0Z -A05 230/ A -A5 or 2 or C42H-B0Z -B0 230/ B0 -B NOTE A C42H-C0Z/C0C -C0 -C0 -C C4H-A0Z -A04 -A05 230/ A -A5 -A20 or 2 or 2 or C4H-B0Z -B0 -B0 230/ B5 -B N/A N/A N/A N/A NOTE A C4H-C0Z/C0C -C0 -C0 -C C0H-A0Z -A05 -A 230/ A5 -A20 or 2 or 2 or 2 or C0H-B0Z -B0 -B0 230/ B5 -B N/A N/A N/A N/A NOTE A C0H-C0Z/C0C -C0 -C0 -C These Minimum Circuit Ampacity values are to be used for sizing the field power conductors. Refer to the National Electrical Code (latest version), Article 3 for power conductor sizing. Caution: When more than one field power circuit is run through one conduit, the conductors must be derated. Pay special attention to note of Table 3 regarding Ampacity Adjustment Factors when more than three (3) conductors are in a raceway. Maximum size of the time delay fuse or HACR type circuit breaker for protection of field wiring conductors. Based on 75 C copper wire. All wiring must conform to the National Electrical Code and all local codes. Maximum KW that can operate with the heat pump on is 4KW. Full heat available during Emergency Heat Mode. Maximum KW that can operate with the heat pump on is KW. Full heat available during Emergency Heat Mode. Maximum KW that can operate with the heat pump on is KW. Full heat available during Emergency Heat Mode. Maximum KW that can operate with the heat pump on is KW. Full heat available during Emergency Heat Mode. IMPORTANT: While this electrical data is presented as a guide, it is important to electrically connect properly sized fuses & conductor wires in accordance with the National Electrical Code & all local codes. NOTE A: -C Models have Rotary Disconnect. C0C 40V circuit breaker only available for 0KW. All electrical ratings are the same. Form No. S Supersedes S345-3 Page of 24

10 NOTE: To obtain Quiet Climate Flex sound ratings, a TCURB Model Fig. to Fig. must be used. C**H Unit to Wall Curb Application Guide Fig. No. Curb Model Application Curb Depth Curb Height Used with Unit Model(s) Unit Indoor Air Connections Curb Indoor Air Connections H x W H x W Spacing SA to RA H x W H x W Spacing SA to RA Alt. Spacing SA to RA Shipping Weight Lbs. TCURBF2430A / C24H, C30H 7. x x x x TCURBF342A Used to direct replace CH3S Models..33 5⅜ C3H, C42H. x x x x TCURBF40A Used to direct replace CH4S and CH5S Models / C4H, C0H. x x x x TCURBT2430A 5 TCURBT342A TCURBT40A Used to install 2 or 2.5-ton cabinet machines installed in a soffit. Used to install 3 or 3.5-ton cabinet machines installed in a soffit. Used to install 4 or 5-ton cabinet machines installed in a soffit..33 2¼ C24H, C30H 7. x x x x ¼ C3H, C42H. x x x x ¼ C4H, C0H. x x x x WMICF3A Isolation Curb ⅜ C24H, C30H 7. x x x x WMICF5A Isolation Curb ⅞ C3H, C42H. x x x x WMICF5A Isolation Curb ⅞ C4H, C0H. x x x x Refer to Installation Instruction 20-5 for Spacing TFCT-32A TFCT-53A 2 TFCF-32A 3 TFCF-53A 4 WMRSC3SA Used to install new 2-ton in place of old 2-ton in a soffit. Used to install new 3-ton in place of old 3-ton in a soffit. Used to install new 2-ton in place of old 2-ton. Used to install new 3-ton in place of old 3-ton. Used to install new 3-ton where there are obstacles (conduit, etc) underneath original unit..33 0¼ C24H, C30H 7. x x x.. x ¼ C3H, C42H. x x x x ⅜ C24H, C30H 7. x x x.. x ⅜ C3H, C42H. x x x x C3H. x x x x All curb model numbers followed by -X (beige), -4 (gray), etc to match unit color. All curbs have 4 rubber isolation mounts to reduce vibration to the installation wall. NOTE A: For all economizer applications a TCURB***** is required. For C24 & C30 installations with CHCRV-3 a TCURB is also required. All Dimensions in Inches. Form No. S Supersedes S345-3 Page of 24 SEE NOTE A SEE NOTE A

11 FIG. TCURBF2430A FIG. 2 TCURBF342A 7 " 22 7/" 3 " 27 7 " 40 5 " 42 /" 2 7/" 44 3/" 2 7/" 3 3/4" 7 7 " 3 7 " " 7 5/ 7/" /" 5 7/" 30" 70 " ALT. RETURN 70 5 " POSITION 4 7/" 5 5/" ALT. RETURN POSITION TCURBF2430 TCURBF342 C24H C30H 5/" MIS-32 A C3H C42H 5/" MIS-327 A FIG. 3 TCURBF40A FIG. 4 TCURBT2430A 22 7/" 7 /" 42 /" 2 3/" 44 3/" 3 3 " 7 27 " 40 3 " 3 3/4" 2 7/" 7/" /" 2" 7 7 " 5 7/" 30" 7 5 " 5 5/" 3 /" ALT. RETURN POSITION 70 " 7 3 " 5 2 " TCURBF40 TCURBT2430 C4H C0H 5/" MIS-32 A 7 3/" C24H C30H 5/" MIS-323 A PATENTED UNDER,004,5 Form No. S Supersedes S345-3 Page of 24

12 FIG. 5 TCURBT342A FIG. TCURBT40A 22 7/" 22 7/" 44 /4" 42 /" 2 7/" 44 /4" 42 /" 2 7/" 3 3/4" 3 3/4" 7/" 7/" 24" 24" 30" 30" 5 7/" 5 7/" 7 /" 4 7/" /4" 3 /" /4" TCURBT40 TCURBT342 5/" 7 7/" C3H C42H 5/" MIS-324 A C4H C0H MIS-325 A FIG. 7 WMICF3A FIG. WMICF5A 7 " 22 7/" 3 " " 5 40 " 42 /" 2 3/" 44 /" 2 /" " 7/" 7 " " 30" 70 " 3 7 " 70 " 4 7/" 5 7/" 5" WMICF3 WMICF5 C24H C30H 5 3 " MIS-32 A C3H C42H 3 5/" MIS-3220 A Form No. S Supersedes S345-3 Page 2 of 24 PATENTED UNDER,004,5

13 FIG. WMICF5A FIG. TFCT-32A 22 7/" 7 " 42 /" 44 /" 2 3/" 3 3 " " " 2" 2 3/4" 7/" " 7 7 " 20 " 30" 5" 7 " 3 /" 5 7/" 70 " 5 0 " WMICF5 TFCT32 C4H C0H 3 5/" MIS-322 A C24H C30H 5 " MIS-3222 A * TFCT AND TFCF CURBS MAY REQUIRE WALL MODIFICATION FOR MOUNTING HOLE PATTERN. FIG. TFCT-53A FIG. 2 TFCF-32A 22 7/" 7 /" 42 /" 27 7/" 3 /2" 3 3/" 7/" 33 5/" 3 3/4" 2 3/4" 2 /" 7 7/" 7 5/" 7 7/" 3 7/" 20 /" 4 7/" 2 /4" 70 /" 3/" 70 3/" TFCT53 TFCF32 4 3/4" C3H C42H 5/" MIS-3223 A C24H C30H 5/" MIS-32 A PATENTED UNDER,004,5 Form No. S Supersedes S345-3 Page 3 of 24

14 FIG. 3 TFCF-53A FIG. 4 WMRSC3SA 22 7/" 22 7/" 42 /" 27 7/" 3 7/" 42 /" 27 /" 43 5/" 3 3/4" 7 7/" 3 3/4" 7 7/" 5" 7 7/" 70 3/" 3 7/" 5" 7 7/" 3 7/" 72" TFCF53 WMRSC3S 4 5/" 3" C3H C42H 5/" MIS-3225 A * TFCT AND TFCF CURBS MAY REQUIRE WALL MODIFICATION FOR MOUNTING HOLE PATTERN. C3H C42H 5/" MIS-322 A PATENTED UNDER,004,5 CH Unit & T Curb Economizer Airflow Path 0% OUTSIDE AIRFLOW PATH MIXED AIRFLOW PATH 0% CLOSED LOOP AIRFLOW PATH SUPPLY AIR COOLING COIL SUPPLY AIR COOLING COIL SUPPLY AIR MIST ELIMINATOR AIR FILTER MIST ELIMINATOR AIR FILTER MIST ELIMINATOR AIR FILTER 0% OUTDOOR AIR RETURN AIR 0% OUTDOOR AIR RETURN AIR 0% RETURN AIR DAMPER BLADE CONDENSER AIR CONDENSER AIR CONDENSER AIR EXHAUST AIR MIS-32 CONDENSER COIL EXHAUST AIR MIS-32 CONDENSER COIL MIS-320 Form No. S Supersedes S345-3 Page 4 of 24

15 Acoustical Plenum WAPR 20 /4" 42 3/" 3 3/4" /2" 42 /4" Duct Free Acoustical Plenum 3 3/4" /2" 3/" WAPFB3 7-7/ 27-7/ WAPFB5-7/ 2-7/ WAPFB5FF -7/ 2-7/ A B A 7/" 3 3/4" 34 /4" /2" B 2 7/" /2" MIS-224 A 7" NOTE: WAPFB5FF same as shown, except has square front with grille straight up and down. Optional Installation Accessories Description Model Used With Color Shipping Weight (Lbs) 2 /" MIS-220 A Acoustical Plenum WAPS5-G 44" Acoustical Plenum Duct Free Acoustical Plenum Ducted Acoustical Plenum Duct Free Acoustical Plenum Duct Free Acoustical Plenum WAPR-X WAPR-4 WAPFB3-X WAPFB3-4 C3H-C0H C24H-C30H Beige Buckeye Gray Beige Buckeye Gray WAPS5-G C3H-C0H Galvanized 40 WAPFB5-X WAPFB5-4 WAPFB5FF-X WAPFB5FF-4 C3H-C0H C3H-C0H Beige Buckeye Gray Beige Buckeye Gray " 5" 7/" 4" 3/4" 2 7/" 4" " MIS-24 2" DIA. HOLES FOR DUCT COLLARS. DUCT COLLARS FIELD SUPPLIED. Typical installation with isolation curb, free blow, supply air acoustical plenum & return air acoustical plenum. WMICF5 ISOLATION CURB WAPF5 FREE-BLOW SUPPLY AIR PLENUM AIRFLOW WAPR RETURN AIR ACCOUSTICAL PLENUM Patent,33,72 2" MIN. AIRFLOW MIS-322 A Form No. S Supersedes S345-3 Page 5 of 24

16 Typical Sound Performance with Installation/Isolation Curbs & Acoustical Plenums C24H Sound Data Matrix 5 feet) Free Blow Configuration Unit Mounting TCURBF2430 TCURBF2430 TCURBF2430 Isolation Curb Isolation Curb Isolation Curb Treatment Treatment Blower Only Operation with CRV Stage Operation with CRV Stage 2 Operation Stage 2 with ERV High Speed Operation WAPR-X WAPFB3 Free Blow Plenum WAPR-X Front Outlet Ducted Configuration WAPR-X TCURBF2430 TCURBF2430 Isolation Curb Isolation Curb WAPS5-G WAPR-X NA NA NA NA NA NA NA NA NA Indoor Integrated dba NA NA NA Stage Outdoor Sound Level Note : dba is sound pressure measured 5 feet in front of unit and 5 feet above floor. Note 2: Unit or isolation curb is mounted to frame construction. Note 3: Results may vary depending upon other factors such as room size, type of construction and acoustical variances. C30H Sound Data Matrix 5 feet) Unit Mounting TCURBF2430 TCURBF2430 TCURBF2430 Isolation Curb Isolation Curb Isolation Curb Treatment Treatment WAPR-X WAPFB3 Free Blow Plenum WAPR-X WAPR-X TCURBF2430 TCURBF2430 Isolation Curb Isolation Curb WAPS5-G WAPR-X Blower Only Operation NA NA NA Stage Operation Stage 2 Operation Stage 2 with ERV High Speed Operation Free Blow Configuration Front Outlet Ducted Configuration NA NA NA NA NA NA Indoor Integrated dba NA NA NA Stage Outdoor Sound Level Note : dba is sound pressure measured 5 feet in front of unit and 5 feet above floor. Note 2: Unit or isolation curb is mounted to frame construction. Note 3: Results may vary depending upon other factors such as room size, type of construction and acoustical variances. Form No. S Supersedes S345-3 Page of 24 C3H Sound Data Matrix 5 feet) Unit Mounting TCURBF342 TCURBF342 TCURBF342 Isolation Curb Isolation Curb Isolation Curb Treatment Treatment WAPR-X WAPFB5 Free Blow Plenum WAPR-X WAPR-X TCURBF342 TCURBF342 Isolation Curb Isolation Curb WAPS5-G WAPR-X Blower Only Operation Stage Operation Stage 2 Operation Stage 2 with ERV High Speed Operation Free Blow Configuration Front Outlet Ducted Configuration Indoor Integrated dba ' Stage Outdoor Sound Level Note : dba is sound pressure measured 5 feet in front of unit and 5 feet above floor. Note 2: Unit or isolation curb is mounted to frame construction. Note 3: Results may vary depending upon other factors such as room size, type of construction and acoustical variances.

17 Typical Sound Performance with Installation/Isolation Curbs & Acoustical Plenums C42H Sound Data Matrix 5 feet) Free Blow Configuration Unit Mounting TCURBF342 TCURBF342 TCURBF342 Isolation Curb Isolation Curb Isolation Curb Treatment Treatment Blower Only Operation with CRV Stage Operation with CRV Stage 2 Operation Stage 2 with ERV High Speed Operation WAPR-X WAPFB5 Free Blow Plenum WAPR-X Front Outlet Ducted Configuration WAPR-X TCURBF342 TCURBF342 Isolation Curb Isolation Curb WAPS5-G WAPR-X Indoor Integrated dba Stage Outdoor Sound Level Note : dba is sound pressure measured 5 feet in front of unit and 5 feet above floor. Note 2: Unit or isolation curb is mounted to frame construction. Note 3: Results may vary depending upon other factors such as room size, type of construction and acoustical variances. C4H Sound Data Matrix 5 feet) Unit Mounting TCURBF40 TCURBF40 TCURBF40 Isolation Curb Isolation Curb Isolation Curb Treatment Treatment WAPR-X WAPFB5 Free Blow Plenum WAPR-X WAPR-X TCURBF40 TCURBF40 Isolation Curb Isolation Curb WAPS5-G WAPR-X Blower Only Operation Stage Operation Stage 2 Operation Stage 2 with ERV High Speed Operation Free Blow Configuration Front Outlet Ducted Configuration Indoor Integrated dba Stage Outdoor Sound Level Note : dba is sound pressure measured 5 feet in front of unit and 5 feet above floor. Note 2: Unit or isolation curb is mounted to frame construction. Note 3: Results may vary depending upon other factors such as room size, type of construction and acoustical variances. C0H Sound Data Matrix 5 feet) Unit Mounting TCURBF40 TCURBF40 TCURBF40 Isolation Curb Isolation Curb Isolation Curb Treatment Treatment WAPR-X WAPFB5 Free Blow Plenum WAPR-X WAPR-X TCURBF40 TCURBF40 Isolation Curb Isolation Curb WAPS5-G WAPR-X Blower Only Operation Stage Operation Stage 2 Operation Stage 2 with ERV High Speed Operation Free Blow Configuration Front Outlet Ducted Configuration Indoor Integrated dba Stage Outdoor Sound Level Note : dba is sound pressure measured 5 feet in front of unit and 5 feet above floor. Note 2: Unit or isolation curb is mounted to frame construction. Note 3: Results may vary depending upon other factors such as room size, type of construction and acoustical variances. Form No. S Supersedes S345-3 Page 7 of 24

18 Typical Sound Performance with Installation/Isolation Curbs & Acoustical Plenums C24H Sound Data Matrix feet) Free Blow Configuration Unit Mounting TCURBF2430 TCURBF2430 TCURBF2430 Isolation Curb Isolation Curb Isolation Curb Treatment Treatment Blower Only Operation with CRV Stage Operation with CRV Stage 2 Operation Stage 2 with ERV High Speed Operation WAPR-X WAPFB5 Free Blow Plenum WAPR-X Front Outlet Ducted Configuration WAPR-X TCURBF2430 TCURBF2430 Isolation Curb Isolation Curb WAPS5-G WAPR-X NA NA NA NA NA NA NA NA NA Indoor Integrated dba NA NA NA Stage Outdoor Sound Level Note : dba is sound pressure measured feet in front of unit and 5 feet above floor. Note 2: Unit or isolation curb is mounted to frame construction. Note 3: Results may vary depending upon other factors such as room size, type of construction and acoustical variances. C30H Sound Data Matrix feet) Unit Mounting TCURBF2430 TCURBF2430 TCURBF2430 Isolation Curb Isolation Curb Isolation Curb Treatment Treatment WAPR-X WAPFB5 Free Blow Plenum WAPR-X WAPR-X TCURBF2430 TCURBF2430 Isolation Curb Isolation Curb WAPS5-G WAPR-X Blower Only Operation NA NA NA Stage Operation Stage 2 Operation Stage 2 with ERV High Speed Operation Free Blow Configuration Front Outlet Ducted Configuration NA NA NA NA NA NA Indoor Integrated dba NA NA NA Stage Outdoor Sound Level Note : dba is sound pressure measured feet in front of unit and 5 feet above floor. Note 2: Unit or isolation curb is mounted to frame construction. Note 3: Results may vary depending upon other factors such as room size, type of construction and acoustical variances. Form No. S Supersedes S345-3 Page of 24 C3H Sound Data Matrix feet) Unit Mounting TCURBF342 TCURBF342 TCURBF342 Isolation Curb Isolation Curb Isolation Curb Treatment Treatment WAPR-X WAPFB5 Free Blow Plenum WAPR-X WAPR-X TCURBF342 TCURBF342 Isolation Curb Isolation Curb WAPS5-G WAPR-X Blower Only Operation Stage Operation Stage 2 Operation Stage 2 with ERV High Speed Operation Free Blow Configuration Front Outlet Ducted Configuration Indoor Integrated dba Stage Outdoor Sound Level Note : dba is sound pressure measured feet in front of unit and 5 feet above floor. Note 2: Unit or isolation curb is mounted to frame construction. Note 3: Results may vary depending upon other factors such as room size, type of construction and acoustical variances.

19 Typical Sound Performance with Installation/Isolation Curbs & Acoustical Plenums C42H Sound Data Matrix feet) Free Blow Configuration Unit Mounting TCURBF342 TCURBF342 TCURBF342 Isolation Curb Isolation Curb Isolation Curb Treatment Treatment Blower Only Operation with CRV Stage Operation with CRV Stage 2 Operation Stage 2 with ERV High Speed Operation WAPR-X WAPFB5 Free Blow Plenum WAPR-X Front Outlet Ducted Configuration WAPR-X TCURBF342 TCURBF342 Isolation Curb Isolation Curb WAPS5-G WAPR-X Indoor Integrated dba Stage Outdoor Sound Level Note : dba is sound pressure measured feet in front of unit and 5 feet above floor. Note 2: Unit or isolation curb is mounted to frame construction. Note 3: Results may vary depending upon other factors such as room size, type of construction and acoustical variances. C4H Sound Data Matrix feet) Unit Mounting TCURBF40 TCURBF40 TCURBF40 Isolation Curb Isolation Curb Isolation Curb Treatment Treatment WAPR-X WAPFB5 Free Blow Plenum WAPR-X WAPR-X TCURBF40 TCURBF40 Isolation Curb Isolation Curb WAPS5-G WAPR-X Blower Only Operation Stage Operation Stage 2 Operation Stage 2 with ERV High Speed Operation Free Blow Configuration Front Outlet Ducted Configuration Indoor Integrated dba Stage Outdoor Sound Level Note : dba is sound pressure measured feet in front of unit and 5 feet above floor. Note 2: Unit or isolation curb is mounted to frame construction. Note 3: Results may vary depending upon other factors such as room size, type of construction and acoustical variances. C0H Sound Data Matrix feet) Unit Mounting TCURBF40 TCURBF40 TCURBF40 Isolation Curb Isolation Curb Isolation Curb Treatment Treatment WAPR-X WAPFB5 Free Blow Plenum WAPR-X WAPR-X TCURBF40 TCURBF40 Isolation Curb Isolation Curb WAPS5-G WAPR-X Blower Only Operation Stage Operation Stage 2 Operation Stage 2 with ERV High Speed Operation Free Blow Configuration Front Outlet Ducted Configuration Indoor Integrated dba Stage Outdoor Sound Level Note : dba is sound pressure measured feet in front of unit and 5 feet above floor. Note 2: Unit or isolation curb is mounted to frame construction. Note 3: Results may vary depending upon other factors such as room size, type of construction and acoustical variances. Form No. S Supersedes S345-3 Page of 24

20 Part Load Cooling Application Data - Outdoor Temperature F k Model C24H C30H C3H C42H C4H C0H D.B. / W.B. l 75/2 0/7 5/72 75/2 0/7 5/72 75/2 0/7 5/72 75/2 0/7 5/72 75/2 0/7 5/72 75/2 0/7 5/72 COOLING CAPACITY Below 5 F, unit requires a factory or field installed low ambient control. k Outdoor temperatures shown are measured at the condenser section air inlet. l Return air temperature F. 75 F 0 F 5 F 0 F 5 F 0 F 5 F F 5 F 20 F 7,0 3,00,00 3,400 22,200 3,00 23,0,000 25,0 7,400 2,00 7,00 2,00 20,700 2,400 20,000 33,00 20,0 30,700 23,200 32,700 22,0 3,000 23,0 35,300 27,0 37,700 2,00 44,00 27,300 43,300 33,00 4,200 32,00 55,0 33,700,300 3,200 7,700 2,00 20,700 3,0 22,0 7,0 24,000 7,0 2,0 7,400 24,00 20,0 27,000,700 3,00 20,000 2,0 23,000 3,400 22,0 3,300 22,00 34,000 27,200 35,00 2,00 43,300 27,000 4,300 33,0 43,000 32,400 52,00 32,00 5,300 2,700,00 2,0,400 2,00 20,00 7,000 23,0,00 2,00,00 23,300,0 25,00,300 2,700,400 2,00 22,00 2,0 22,400 33,00 22,0 32,00 2,00 3,200 2,0 4,00 2,00 3,0 32,300 43,00 32,000,300 32,200 4,200 2,0,000 2,0,0 2,0,00,400 22,0,400 25,000,300 2,00,000 24,00,000 27,00,00 24,00 22,0 2,0 22,0 3,00 22,000 3,200 2,300 35,200 2,300 3,00 2,0 37,0 3,400 42,400 3,400 47,00 3,200 3,0,00 5,000,700,700,0,0,000 2,200,0 23,00 5,00 20,400,400 23,400,0 2,000,200 23,400 2,0 2,00 2,700 2,00 2,300 2,00 25,700 34,000 25,00 37,00 25,400 35,0 30,0 40,00 30,00 45,300 30,200 2,0,200 4,0,400 5,0,0 7,0 5,0 20,400 5,700 22,300 5,200,300 7,00 22,400,0 24,0 7,0 22,0 20,00 25,700 2,200 2,0 20,0 2,0 25,0 32,700 25,0 35,00 24,700 33,700 2,00 3,200 30,0 42,00 2,0,200,00 3,200,0 4,300,00,00 4,00,00 5,300 2,200 4,00,200 7,200 2,400 7,00 23,0,00 2,000 20,0 24,00 20,00 2,00,700 2,0 24,300 3,200 24,00 33,700 23,00 3,00 2,700 37,0 2,400 40,0 2,000,400,00 2,300,00 3,0,300 5,00 4,0,00 5,000 20,000 4,0 7,200,00 20,0 7,0 2,00,0 20,200,200 24,000,00 25,00,00 24,00 23,300 2,0 24,0 3,400 22,00 30,000 27,700 35,700 2,00 3,000 2,00 Capacity Multiplier Factors,0,300,400,700 2,000,00 5,000 4,000,000 4,0,00 3,400,300 5,00,00,0 20,00 5,200,400,0 23,300,00 24,0 7,300 23,000 22,400 27,700 23,300 2,0 2,0 2,0 2,700 33,00 27,00 35,0 25,00,00,0,400,0,00,0 4,300 3,0 7,300 4,0,000 2,00 5,0 5,200,00 5,00,00 4,400,00 7,000 22,00 7,00 23,700,0 2,200 2,300 25,700 22,300 2,700 20,200 2,300 25,700 3,00 2,00 33,0 24,300 % of Rated Airflow - Rated + Total BTUH Sensible BTUH Part Load Heating Application Rating & Outdoor Temperature F* k MODEL F C24H C30H C3H C42H C4H C0H BTUH WATTS COP BTUH WATTS COP BTUH WATTS COP BTUH WATTS COP BTUH WATTS COP BTUH WATTS COP 3, , , , , , , , , , , , , , , , , , , , , , ,200 2.,00 20.,0 420., ,0 0.4, , , , , , , , , * 70 F DB indoor return air at rated CFM includes defrost operation below 45. k Outdoor temperatures shown are measured at the condenser section air inlet. Form No. S Supersedes S345-3 Page 20 of 24, , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,

21 Full Load Cooling Application Data - Outdoor Temperature F k Model C24H C30H C3H C42H C4H C0H D.B. / W.B. l 75/2 0/7 5/72 75/2 0/7 5/72 75/2 0/7 5/72 75/2 0/7 5/72 75/2 0/7 5/72 75/2 0/7 5/72 COOLING CAPACITY Below 5 F, unit requires a factory or field installed low ambient control. k Outdoor temperatures shown are measured at the condenser section air inlet. l Return air temperature F. 75 F 0 F 5 F 0 F 5 F 0 F 5 F F 5 F 20 F 24,400,200 2,000,00 3,000,0 3,200 24,300 33,300 23,0 3,700 24,0 37,200 2,0 3,700 2,00 47,300 2,300 42,0 33,400 44,00 32,400 53,0 33,200 4,00 3,400 52,0 3,200 2,0 3,0 5,0 45,200 2,000 43,00 73,00 44,00 23,200,00 2,000,00 2,0,700 2,00 23,400 32,200 22,00 37,700 23,300 35,0 2,700 3,00 2,0 45,200 2,0 40,0 32,400 43,700 3,700 5,0 32,200 4,00 3,0,00 37,700 5,400 3,300 55,00 43,700 0,00 42,00 70,00 43,400 22,000,300 24,400,0 2,0,200 2,0 22,00 3,200 22,400 35,00 22,0 33,00 27,00 37,0 27,0 43,0 27,700 3,300 3,300 42,0 3,000 4,00 3,200 44,00 37,00 4,0 37,200 5,00 37,400 53,200 42,400 5,0 42,000 7,00 42,200 20,700 7,700 23,400 7,700 2,0 7,00 2,700 22,000 30,200 22,000 34,0 2,00 32,0 2,00 3,300 2,00 4,000 2,700 3,0 30,400 4,200 30,400 4,0 30,200 42,0 3,700 4,000 3,700 54,200 3,0 5,000 4,0 57,00 4,0 5,000 40,00,400 7,200 22,200 7,300 24,700 7,000 25,0 2,300 2,200 2,0 32,0 2,0 30,0 2,0 35,000 2,300 3,00 25,00 34,700 2,0 40,000 2,700 44,200 2,200 40,0 35,700 45,0 3,000 5,700 35,300 4,00 3,00 55,0 40,300 2,200 3,0,0,0 2,000,00 23,000,300 24,300 20,00 2,300 2,0 3,000 20,400 2,00 25,300 33,700 25,700 3,00 24,00 33,000 2,00 3,400 2,0 42,000 2,200 3,00 34,00 45,000 35,400 4,200 34,300 4,700 3,00 54,400 3,0 5,0 3,200,700 5,00,700,200 2,300 5,0 23,200 20,200 27,300 20,700 2,0,00 27,400 24,0 32,300 25,0 34,00 23,00 3,300 27,00 3,00 2,0 3,00 27,200 3,00 33,00 43,400 34,700 4,00 33,0 44,700 37,00 52,700 3,00 5,00 37,000 5,400 5,0,300 5,00,0 4,700 22,0,700 2,300 20,300 2,000,0 25,00 23,00 30,00 24,400 32,00 22,00 2,700 27,0 35,400 2,000 37,700 2,300 35,000 32,00 4,700 33,00 44,400 3,00 42,700 3,00,00 3,0 54,200 35,700 Capacity Multiplier Factors 3,00 4,400,700 4,00 7,00 3,00 2,000,200 25,300,00 2,00,400 24,400 22,00 2,300 23,00 30,00 2,00 2,0 2,400 33,00 27,400 35,0 25,300 33,200 3,00 3,00 33,0 4,00 30,0 40,00 3,000 4,0 37,400 5,00 34,0 2,400 3,00 5,000 4,200 5,00 2,00 20,0,00 24,300,00 25,300 7,700 22,00 22,0 27,700 23,0 2,00 20,00 2,0 25,700 32,0 2,00 33,400 24,300 3,400 30,00 3,000 32,200 3,0 2,0 3,00 35,200 47,200 3,00 4,0 33,300 % of Rated Airflow - Rated + Total BTUH Sensible BTUH Full Load Heating Application Rating & Outdoor Temperature F* k MODEL F C24H C30H C3H C42H C4H C0H BTUH WATTS COP BTUH WATTS COP BTUH WATTS COP BTUH WATTS COP BTUH WATTS COP BTUH WATTS COP 5, , , , , , , , , , , , , , , , , , , , , , , , ,0 0., , , , , , , , , , , * 70 F DB indoor return air at rated CFM includes defrost operation below 45. k Outdoor temperatures shown are measured at the condenser section air inlet. 3, , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , Form No. S Supersedes S345-3 Page 2 of 24

22 Indoor Blower Performance - CFM (0.00" 0." H 2 0) Model Rated ESP j Max ESP k Blower Only Cooling & Heat Pump Stage m Cooling & Heat Pump Stage 2 C24H C30H m Electric Heat C3H C42H C4H C0H NOTE: These units are equipped with a variable speed (ECM) indoor motor that automatically adjusts itself to maintain approximately the same rate of indoor airflow in both heating & cooling, dry & wet coil conditions and at both 230/20 or 40 volts. Maximum ESP (inches WC) shown is with 2" thick disposable filter. Blower only CFM is the total air being circulated during continuous fan only mode. Blower only CFM reduces during continuous fan only mode. CFM output on Stage 2 Cooling and Heat Pump or Electric Heat. Electric Heat Table - Refer to Electrical Specifications for Availability by Unit Model Nominal KW KW -Ph Amps At 240V () At 20V () At 40V (2) At 40V (2) 3-Ph Amps Btuh KW () These electric heaters are available in 230/20V units only. (2) These electric heaters are available in 40V units only. -Ph Amps 3-Ph Amps Btuh , , , , , , , , , , , , , , , , , , , , , , , , , ,5 KW 3-Ph Amps Btuh KW 3-Ph Amps Btuh Heater Packages - Field Installed Designed for adding Electric Heat to 0 KW Units Circuit Breaker standard on 230/20V Models Heat Pump Models C24H C30H C3H C42H C4H C0H -A00 Models 230/20- -B00 Models 230/20-3 ETL US & Canada Listed Rotary Disconnect standard on 40V Models -C00 Models 40-3 Heater Model # KW Heater Model # KW Heater Model # KW EHT03H-A04B EHT03H-AFB EHT03H-ASB EHT03H-A04B EHT03H-AFB EHT03H-ASB EHS03H-A05B EHT05H-AB EHT05H-A5B EHS03H-A05B EHT05H-AB EHT05H-A5B EHT0H-A04B EHT0H-A05B EHT0H-AB EHT0H-A5B EHT0H-A20B EHT0H-A05B EHT0H-AB EHT0H-A5B EHT0H-A20B 4 F S 4 F S EHT02H-B0B EHT03H-B0B EHT03H-B0B EHT03H-B0B EHT05H-B0B EHT05H-B0B EHS05H-B5B EHS05H-B0B EHS05H-B0B EHS05H-B5B EHT0H-B0B EHT0H-B0B EHT0H-B5B EHT0H-BB EHT0H-B0B EHT0H-B0B EHT0H-B5B EHT0H-BB EHT03H-C0 EHT03H-C0 EHS05H-C0 EHS03H-C0 EHS03H-C5 EHS05H-C0 EHS05H-C0 EHS05H-C5 EHT0H-C0 EHT0H-C0 EHT0H-C5 EHT0H-C0 EHT0H-C0 EHT0H-C5 EHT0H-C Form No. S Supersedes S345-3 Page 22 of 24

THE WALL-MOUNT QUIET-CLIMATE HEAT PUMPS

THE WALL-MOUNT QUIET-CLIMATE HEAT PUMPS THE WALL-MOUNT QUIET-CLIMATE HEAT PUMPS Models: SH21, SH311, SH31, SH431, SH41, SH High Efficiency Heating Capacities: 21, to 55, Ultra Low Sound Level Cooling Capacities: 23, to 55, Refrigerant 22 The

More information

Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed.

Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed. THE WALL-MOUNT AIR CONDITIONERS -. EER, (HZ) Models WAA to W72AA Right-Side Control Panel Models WLA to W72LA Left-Side Control Panel. to Ton (7, to 7, Btuh) Green Refrigerant R-4A The Bard Wall-Mount

More information

The Wall-Mount Step Capacity Gas/Electric - WG*S Series Integrated Part Load Value (IPLV) Efficiency Up to 15.6 BTU/WATT.

The Wall-Mount Step Capacity Gas/Electric - WG*S Series Integrated Part Load Value (IPLV) Efficiency Up to 15.6 BTU/WATT. The Wall-Mount Step Capacity Gas/Electric - WG*S Series Integrated Part Load Value (IPLV) Efficiency Up to 15.6 BTU/WATT WG3S2, WG4S2, WG5S2 6HZ 24, to 56,5 BTUH Cooling Capacity 37, to 12,5 BTUH Heating

More information

GREEN REFRIGERANT R-410A

GREEN REFRIGERANT R-410A THE WALL-MOUNT STEP CAPACITY AIR CONDITIONERS Integrated Part Load Value (IPLV) Efficiency Up To. BTU/WATT WAS WAS Right Side Control Panel WLS WLS Left Side Control Panel to Ton (,4 to, Btuh) Hz GREEN

More information

GREEN REFRIGERANT R-410A

GREEN REFRIGERANT R-410A WLL-MOUNT -TON IR CONDITIONERS J7 - Right Side Control Panel J7L - Left Side Control Panel, 9.5 EER Hz Solair Wall-Mount ir Conditioner is a self contained energy efficient system, which is designed to

More information

I-TEC TM I30H-I60H 2-Stage Compressor High Efficiency Air Source Heat Pumps

I-TEC TM I30H-I60H 2-Stage Compressor High Efficiency Air Source Heat Pumps I-TEC TM IH-IH 2-Stage Compressor High Efficiency Air Source Heat Pumps Cooling Capacities: 20,0 to 55,000 Btuh Heating Capacities: 20,200 to 54,500 Btuh The Bard I-TEC Indoor Heat Pump system is designed

More information

Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed.

Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed. THE WALL-MOUNT AIR CONDITIONER -. EER, (HZ) Models WAA to W7AA Right-ide Control Panel Models WLA to W7LA Left-ide Control Panel. to Ton (7, to 7, Btuh) The Bard Wall-Mount Air Conditioner is a self contained

More information

THE WALL-MOUNT AIR CONDITIONERS - WA (60HZ)

THE WALL-MOUNT AIR CONDITIONERS - WA (60HZ) THE WLL-MOUNT IR CONDITIONERS - W (HZ) W-SERIES Refrigerant 22 Hz. to Ton (, to 7, Btuh) Right Side Control Panel The Bard Wall-Mount ir Conditioner is a self contained energy efficient system, which is

More information

THE WALL-MOUNT AIR CONDITIONERS - WA (60HZ)

THE WALL-MOUNT AIR CONDITIONERS - WA (60HZ) THE WLL-MOUNT IR CONDITIONERS - W (HZ) W-SERIES Hz. to Ton (,3 to 7, Btuh) Right Side Control Panel Refrigerant The Bard Wall-Mount ir Conditioner is a self contained energy efficient system, which is

More information

THE WALL-MOUNT GAS/ELECTRIC - WG-SERIES

THE WALL-MOUNT GAS/ELECTRIC - WG-SERIES THE WALL-MOUNT GASELECTRIC - WG-SERIES WG - SERIES to Ton 3, to 6, BTUH Capacity 1, to 1, BTUH Heating Input 6HZ The Bard Wall-Mount Electric Air Conditioner with gas fired heating is a self contained

More information

V High Efficiency Series

V High Efficiency Series UNIT DISCONNECT(S) BEHIND THIS PANAL Commercial HVAC V High Efficiency Series Wallmount Air Conditioners PERFORMANCE: Efficiency rating of 9.0/9.5 EER Electric heat available from 5 kw to 18 kw Designed

More information

Tons BTU/h S.E.E.R* E.E.R** HSPF

Tons BTU/h S.E.E.R* E.E.R** HSPF SOUND REFRIGERANT ENVIRONMENTALLY PHD3 Product Specifications 13 SEER, R -410A PACKAGE HEAT PUMP, 2½ to 5 TONS 3 -Phase, 208/230-3 -60 and 460-3 -60 REFRIGERATION CIRCUIT R--410A refrigerant Copper tube/aluminum

More information

Product Data. Features/Benefits 50JS SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS)

Product Data. Features/Benefits 50JS SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS) SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS) Product Data UNIT (50 Hz) Single-packaged Heat Pump for Residential and Light Commercial applications. Features/Benefits One-piece

More information

CHP

CHP Packaged Unit Heat Pump CHP16-024-030-036-048-060 2-5 Ton Cooling 23,000-57,500 Btuh Heating 12,800-85,300 Btuh (5-25 kw) Optional Electric Heating FEATURES Designed for outdoor rooftop or ground level

More information

M-SERIES MHP4 MODEL NUMBER GUIDE 3 M HP F P 1 ELECTRIC HEAT PUMP PACKAGED UNITS REVISION CODE

M-SERIES MHP4 MODEL NUMBER GUIDE 3 M HP F P 1 ELECTRIC HEAT PUMP PACKAGED UNITS REVISION CODE ELECTRIC HEAT PUMP PACKAGED UNITS MHP4 FORM NO. MHP4-100 (10/2018) MODEL NUMBER GUIDE 3 M HP 4 11 18 1 F P 1 FACTORY INSTALLED ELECTRIC HEAT 3= 3 KW 5 = 5 KW 7 = 7 KW 10 = 10 KW M = MAGIC-PAK HP = HEAT

More information

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS Q6SD Series Single Packaged Heat Pump, Single Phase Q6SD-13 SEER, R-410A 2-5 Ton Units Cooling: 22,800 to 58,500 Btuh Heating: 22,800 to 58,500 Btuh The Q6 Series single packaged

More information

GREEN REFRIGERANT R-410A

GREEN REFRIGERANT R-410A s J7L to JL. to Ton (, to, Btuh) Left ide Control Panel Hz olair Wall-Mount ir Conditioner is a self contained energy efficient system, which is designed to offer maximum indoor comfort at a minimal cost

More information

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS TECHNICAL SPECIFICATIONS S5BP Series Split System Air Conditioner 71/2 Ton Energy Star rated at 11.7 EER and 11.8 IEER 10 Ton rated at 11.2 EER and 11.5 IEER R-410A Refrigerant The S5BP Series of air conditioners

More information

RPHP13. Product Specifications. 13 SEER Heat Pump Residential Packaged Unit. Refrigerant System. Cabinet Construction. Blower. Controls.

RPHP13. Product Specifications. 13 SEER Heat Pump Residential Packaged Unit. Refrigerant System. Cabinet Construction. Blower. Controls. RPHP13 Product Specifications Refrigerant System Environmentally friendly R410A refrigerant Copper tubing with enhanced fin coils External service gauge ports 13 SEER Heat Pump Residential Packaged Unit

More information

Product Data. Features/Benefits. OMNIZONE 50XCR06-24 Remote Air-Cooled Indoor Self-Contained Systems with PURON Refrigerant (R-410A)

Product Data. Features/Benefits. OMNIZONE 50XCR06-24 Remote Air-Cooled Indoor Self-Contained Systems with PURON Refrigerant (R-410A) Product Data OMNIZONE 50XCR06-24 Remote Air-Cooled Indoor Self-Contained Systems with PURON Refrigerant (R-410A) 5 to 20 Nominal Tons The 50XCR single-package remote aircooled units offer: Compact, durable,

More information

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS 50Hz Single Package Rooftop, Cooling Only with Puronr (R---410A) Refrigerant One Stage Cooling Capacity Control: Size 07 Two Stage Cooling Capacity Control: Sizes 08, 09, 12 & 14 Submittal Data PERFORMANCE

More information

RCE13. Product Specifications. 13 SEER Electric / Electric Residential Packaged Unit. Refrigerant System. Cabinet Construction. Blower.

RCE13. Product Specifications. 13 SEER Electric / Electric Residential Packaged Unit. Refrigerant System. Cabinet Construction. Blower. RCE13 Product Specifications 13 SEER Electric / Electric Residential Packaged Unit Form No. RCE13-100 (04/2013) Refrigerant System Environmentally friendly R410A refrigerant Copper tubing with enhanced

More information

PA95 12 SEER FEATURES 2 THRU 4 TON SINGLE PACKAGE

PA95 12 SEER FEATURES 2 THRU 4 TON SINGLE PACKAGE PACKAGE AIR CONDITIONER PA95 12 SEER C 2 THRU 4 TON SINGLE PACKAGE FEATURES CONSTRUCTED FOR DURABILITY All panels made from galvanized steel pre--coated inside and out -- using a polyester top coat, on

More information

Q6SE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase

Q6SE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS Q6SE Series Single Packaged Heat Pump, Single Phase Q6SE-14 SEER, 8.0 HSPF 2-5 Ton Units Cooling: 23,000 to 58,000 Btuh Heating: 22,800 to 59,000 Btuh The Q6 Series single packaged

More information

Q6SP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

Q6SP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11. TECHNICAL SPECIFICATIONS Q6SP Series 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.0 EER Commercial Systems Meet or Exceed ASHRAE 90.1 These 7½ and 10 ton units are designed specifically

More information

Product Data. Features/Benefits. Omnizone 50XCA06-14 Air-Cooled Indoor Self-Contained Systems with Puron Refrigerant (R-410A) 5 to 12 Nominal Tons

Product Data. Features/Benefits. Omnizone 50XCA06-14 Air-Cooled Indoor Self-Contained Systems with Puron Refrigerant (R-410A) 5 to 12 Nominal Tons Product Data Omnizone 50XCA06-14 Air-Cooled Indoor Self-Contained Systems with Puron Refrigerant (R-410A) 5 to 1 Nominal Tons The 50XCA single-package cooling units with integral air-cooled condensers

More information

ELITE SERIES R-410A Ready - Multi-Position

ELITE SERIES R-410A Ready - Multi-Position PRODUCT SPECIFICATIONS AIR HANDLERS CBXM ELITE SERIES R-0A Ready - Multi-Position Bulletin No. 0 October 07 Supersedes June 0 Nominal Capacity -. to Tons Optional Electric Heat -. to 0 kw MODEL NUMBER

More information

GQ6SD Series. Single Packaged Heat Pump 13 SEER, R-410A 2-5 Ton Units TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY

GQ6SD Series. Single Packaged Heat Pump 13 SEER, R-410A 2-5 Ton Units TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY TECHNICAL SPECIFICATIONS GQ6SD Series Single Packaged Heat Pump 13 SEER, R-410A 2-5 Ton Units The GQ6 Series single packaged units are high efficiency self contained cooling and heating units that can

More information

PACKAGE AIR CONDITIONERS

PACKAGE AIR CONDITIONERS PACKAGE AIR CONDITIONERS FORM NO. S22-92 REV. 2 Supersedes Form No. S22-92 Rev. RLNA- SUPER HIGH EFFICIENCY SERIES NOMINAL SIZES -5 TONS [0.6-7.6 kw] *Unit shown with optional louver panels installed..0

More information

Q5RD Series Single Packaged Heat Pump, Single Phase

Q5RD Series Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS Q5RD Series Single Packaged Heat Pump, Single Phase 13 SEER, R-410A 2 thru 5 Ton Units Cooling: 24,000 to 56,000 Btuh Heating: 24,000 to 54,500 Btuh The Q5 Series single packaged

More information

Q7RE Series Single Packaged Heat Pump, Single Phase

Q7RE Series Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS Q7RE Series Single Packaged Heat Pump, Single Phase 14 SEER, 8.0 HSPF 2 thru 5 Ton Units Cooling: 23,400 to 55,500 Btuh Heating: 21,800 to 56,000 Btuh The Q7 Series single packaged

More information

Q7RE Series Single Packaged Heat Pump, Single Phase

Q7RE Series Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS Q7RE Series Single Packaged Heat Pump, Single Phase 14 SEER, 8.0 HSPF 2 thru 5 Ton Units Cooling: 23,400 to 55,500 Btuh Heating: 21,800 to 56,000 Btuh The Q7 Series single packaged

More information

Q3RD Series. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

Q3RD Series. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS TECHNICAL SPECIFICATIONS Q3RD Series Single Packaged Heat Pump, Single Phase Q3RD-13 SEER 2 thru 4 Ton Units Cooling: 24,000 to 48,000 Btuh Heating: 23,200 to 48,000 Btuh The Q3 Series single packaged

More information

FSH1BG Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Ultra High Efficiency Heat Pump, Up to 19 SEER Residential System 2-5 Ton Capacities

FSH1BG Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Ultra High Efficiency Heat Pump, Up to 19 SEER Residential System 2-5 Ton Capacities TECHNICAL SPECIFICATIONS FSH1BG Series Ultra High Efficiency Heat Pump, Up to 19 SEER Residential System 2-5 Ton Capacities The iq Drive heat pump system features modulating compressor technology and variable

More information

P6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Electric Cooling Units EER Commercial System Units

P6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Electric Cooling Units EER Commercial System Units TECHNICAL SPECIFICATIONS P6SP Series Rev A 6, 7½ and 10 Ton Packaged Electric Cooling Units 11.2 EER Commercial System Units These units are designed specifically for retrofit applications and compatibility

More information

GQ5RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase 13 SEER, R-410A, WARRANTY

GQ5RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase 13 SEER, R-410A, WARRANTY TECHNICAL SPECIFICATIONS GQ5RD Series Single Packaged Heat Pump, Single Phase 13 SEER, R-410A, 2 thru 5 Ton Units Cooling: 24,000 to 56,000 Btuh Heating: 24,000 to 54,500 Btuh The GQ5 Series single packaged

More information

CONVERTIBLE SINGLE PACKAGE HEAT PUMP

CONVERTIBLE SINGLE PACKAGE HEAT PUMP PHA D SERIES UNITARY AIRCONDITIONING MANUFACTURER CERTIFIED TO ARI AS COMPLYING WITH ARI EQUIPMENT STANDARD 210 CONVERTIBLE SINGLE PACKAGE HEAT PUMP FEATURE SINGLE PACKAGE, 2 THRU 5 TON COOLING Single

More information

Q6SD Series 13 SEER, Three Phase, Packaged Heat Pump with R-410A 3-5 Ton Units

Q6SD Series 13 SEER, Three Phase, Packaged Heat Pump with R-410A 3-5 Ton Units TM TECHNICAL SPECIFICATIONS Q6SD Series 13 SEER, Three Phase, Packaged Heat Pump with R-410A 3-5 Ton Units The Q6SD Series packaged units are high efficiency self contained cooling and heating units that

More information

PHR5. Product Specifications

PHR5. Product Specifications PHR5 Product Specifications UP to 15.5 SEER, UP to 12.5 EER, PACKAGE HEAT PUMP UNITS, 2 5 TONS 208/230 Volt, 1 phase, 60 Hz 208/230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally balanced R

More information

13 SEER. Light Commercial 3 Phase Packaged Heat Pump. RHP13 Features and Benefits. Refrigerant System. Cabinet Construction. Blower.

13 SEER. Light Commercial 3 Phase Packaged Heat Pump. RHP13 Features and Benefits. Refrigerant System. Cabinet Construction. Blower. 13 SEER Light Commercial 3 Phase Packaged Heat Pump RHP13 Features and Benefits Form No. AC-RHP13-100 (05/2013) Refrigerant System Environmentally friendly R410A refrigerant Copper tubing with enhanced

More information

S6BQ Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Split System 2-Stage Air Conditioner. 7 1/2 and 10 Ton rated at 11.2 EER and 12.

S6BQ Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Split System 2-Stage Air Conditioner. 7 1/2 and 10 Ton rated at 11.2 EER and 12. TECHNICAL SPECIFICATIONS S6BQ Series Split System 2-Stage Air Conditioner 7 1/2 and 10 Ton rated at 11.2 EER and 12.9 IEER The S6BQ Series of air conditioners offers exceptional performance. The unit,

More information

SUNLINE 2000 TM TECHNICAL GUIDE DESCRIPTION SINGLE PACKAGE AIR-TO-AIR HEAT PUMPS

SUNLINE 2000 TM TECHNICAL GUIDE DESCRIPTION SINGLE PACKAGE AIR-TO-AIR HEAT PUMPS TECHNICAL GUIDE SUNLINE 2000 TM SINGLE PACKAGE AIR-TO-AIR HEAT PUMPS MODELS B2CH 180 & B1CH 240 15 & 20 NOMINAL TONS 9.9-8.8 EER DESCRIPTION York Sunline 2000 Heat Pumps are convertible single package

More information

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11. TECHNICAL SPECIFICATIONS Q6SP Series Rev A 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.0 EER Commercial Systems Meet or Exceed ASHRAE 90.1-2010 These 7½ and 10 ton units are designed

More information

GQ5RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase 13 SEER, R-410A, WARRANTY

GQ5RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase 13 SEER, R-410A, WARRANTY TECHNICAL SPECIFICATIONS GQ5RD Series Single Packaged Heat Pump, Single Phase 13 SEER, R-410A, 2 thru 5 Ton Units Cooling: 24,000 to 56,000 Btuh Heating: 24,000 to 54,500 Btuh The GQ5 Series single packaged

More information

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS 50FP-1SB 50FP034, 038, 044, 048, 054, 064, 074 SINGLE-PACKAGE COOLING UNITS CONSTANT/VARIABLE VOLUME PRODUCT INTEGRATED CONTROLS CARRIER COMFORT NETWORK COMPATIBLE FACTORY-INSTALLED OPTIONAL ELECTRIC HEAT

More information

PCB COMMERCIAL SERIES

PCB COMMERCIAL SERIES PCB COMMERCIAL SERIES 50 Hz SELF-CONTAINED PACKAGE CONDITIONER 7½, 0, AND 5 TON [6.4 kw to 5.8 kw] COOLING CAPACITY: 90,000 TO 80,000 BTU/H The PCB Commercial 50 Hz self-contained packaged air conditioner

More information

Product Data PH3Z 13 SEER SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -22 REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS ( )

Product Data PH3Z 13 SEER SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -22 REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS ( ) 13 SEER SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -22 REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS (024-0) Product Data Fig. 1 - Unit 664B Single -Packaged Heat Pump Units with: S easy installation

More information

ENERGY RECOVERY SYSTEM 60 HZ

ENERGY RECOVERY SYSTEM 60 HZ I N D O O R A I R Q U A L I T Y E N G I N E E R I N G D A T A ENERGY RECOVERY SYSTEM 60 HZ Bulletin No. 210517 April 2008 Supersedes 210368 April 2007 300 to 6200 cfm Capacity MODEL NUMBER IDENTIFICATION

More information

SINGLE PACKAGE HEAT PUMPS

SINGLE PACKAGE HEAT PUMPS SINGLE PACKAGE HEAT PUMPS HPP024 THRU 060 2 THRU 5 NOMINAL TONS 13 SEER FACTORY MOUNTED TXV DESCRIPTION These packaged heat pumps are designed for outdoor installation. Only utility and duct connections

More information

PAB SERIES 3thru6-1/3Ton. Belt Drive 10 SEER CONVERTIBLE SINGLE PACKAGE AIR CONDITIONING UNIT /01

PAB SERIES 3thru6-1/3Ton. Belt Drive 10 SEER CONVERTIBLE SINGLE PACKAGE AIR CONDITIONING UNIT /01 PAB SERIES 3thru6-1/3Ton Belt Drive CONVERTIBLE SINGLE PACKAGE AIR CONDITIONING UNIT 10 SEER SINGLE PACKAGE Electric cooling, self contained for year-round comfort. Systems can be installed on roof top

More information

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units 11.0 EER

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units 11.0 EER TECHNICAL SPECIFICATIONS Q6SP Series Rev A 7.5 and 10 Ton Packaged Electric Heat Pump Units 11.0 EER Commercial Systems Meet or Exceed ASHRAE 90.1-2010 These 7½ and 10 ton units are designed specifically

More information

DESCRIPTION FEATURES

DESCRIPTION FEATURES SPLIT-SYSTEM AIR COOLED CONDENSING UNIT H5CE150, H5CE180 AND H5CE240 12-1/2, 15 AND 20 NOMINAL TONS (World 50Hz) DESCRIPTION These outdoor condensing units are completely assembled, piped and wired at

More information

SUNLINE 2000 SINGLE PACKAGE AIR - TO - AIR HEAT PUMPS DESCRIPTION. B1CH 180 & and 20 NOMINAL TONS ( EER)

SUNLINE 2000 SINGLE PACKAGE AIR - TO - AIR HEAT PUMPS DESCRIPTION. B1CH 180 & and 20 NOMINAL TONS ( EER) 511.06-TG3Y (0600) SINGLE PACKAGE AIR - TO - AIR HEAT PUMPS B1CH 1 & 40 15 and 0 NOMINAL TONS (8.5-8.8 EER) SUNLINE 000 DESCRIPTION York Sunline 000 Heat Pumps are convertible single package units. All

More information

AIR HANDLERS RBHM- SERIES AIR HANDLERS AND FAN COIL UNIT

AIR HANDLERS RBHM- SERIES AIR HANDLERS AND FAN COIL UNIT FORM NO. H11-521 AIR HANDLERS earth friendly refrigerant RBHM- SERIES AIR HANDLERS AND FAN COIL UNIT Features Versatile 3-way convertible design for upflow, horizontal left and horizontal right. Available

More information

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE CHS Product Specifications COMMERCIAL SPLIT SYSTEMS HT PUMP UNITS R 410A, 6 20 TONS BUILT TO LAST, SY TO INSTALL AND SERVICE Single stage cooling capacity control on 0 to 121 models, two stage cooling

More information

TECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW

TECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW MODELS: D4HH 024 THRU 180 York horizontal ductable air conditioning packages offer a complete line of

More information

PHF SERIES THREE PHASE CONVERTIBLE SINGLE PACKAGE HEAT PUMP

PHF SERIES THREE PHASE CONVERTIBLE SINGLE PACKAGE HEAT PUMP PHF SERIES UNITARY AIR-CONDITIONING MANUFACTURER CERTIFIED TO ARI AS COMPLYING WITH ARI THREE PHASE EQUIPMENT STANDARD 210 Rated in accordance with ARI Standard Listed By 240. Certification applies only

More information

AIR HANDLERS UBHN- SERIES AIR HANDLERS AND FAN COIL UNIT PRELIMINARY NOT FOR DISTRIBUTION

AIR HANDLERS UBHN- SERIES AIR HANDLERS AND FAN COIL UNIT PRELIMINARY NOT FOR DISTRIBUTION FORM NO. H22-522 AIR HANDLERS earth friendly refrigerant PRELIMINARY NOT FOR DISTRIBUTION UBHN- SERIES AIR HANDLERS AND FAN COIL UNIT Features Versatile 3-way convertible design for upflow, horizontal

More information

PHB SERIES 7-1/2 and 10 TON

PHB SERIES 7-1/2 and 10 TON PHB SERIES 7-1/2 and 10 TON COMMERCIAL SINGLE PACKAGE HEAT PUMPS COMMERCIAL PACKAGE HEAT PUMP FEATURES Representative photo only, some models may vary in appearance. Rated in accordance with ARI Standard

More information

10AC DIPLOMAT SERIES RFC SYSTEMS

10AC DIPLOMAT SERIES RFC SYSTEMS 10AC DIPLOMAT SERIES CONDENSING UNITS RFC SYSTEMS 10.05 to 10.55 SEER *11,100 to 60,000 Btuh (3.3 to 17.6 ) 1 thru 5 Tons (3.5 to 17.6 ) *ARI and DOE Certified Ratings CONDENSING ENGINEERING UNITS DATA

More information

GP7RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner, Single Phase WARRANTY

GP7RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner, Single Phase WARRANTY TECHNICAL SPECIFICATIONS GP7RD Series Single Packaged Air Conditioner, Single Phase GP7RD 13 SEER, R-410A 2 thru 4 Ton Units Cooling: 24,000 to 47,000 Btuh The GP7 Series single packaged air conditioners

More information

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINTS

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINTS 50FN-1SB 50FNX,FNY078,088,104 SINGLE-PACKAGE COOLING UNITS CONSTANT/VARIABLE AIR VOLUME PRODUCT INTEGRATED CONTROLS CARRIER COMFORT NETWORK COMPATIBLE WITH INTEGRAL ECONOMIZER AND HIGH-CAPACITY MODULATING

More information

HCH6. Product Specifications

HCH6. Product Specifications HCH6 Product Specifications HIGH EFFICIENCY 16 SEER TWO- STAGE HEAT PUMP WITH OBSERVERt COMMUNICATING CONTROL SYSTEM 2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt, 1- phase, 60 Hz REFRIGERATION CIRCUIT S Copeland

More information

2SA13 60HZ P A C K A G E D E L E C T R I C / E L E C T R I C

2SA13 60HZ P A C K A G E D E L E C T R I C / E L E C T R I C P A C K A G E D E L E C T R I C / E L E C T R I C 2SA13 60HZ E N G I N E E R I N G D A T A Bulletin No. 210454 August 06 Supersedes July 06 MODEL NUMBER IDENTIFICATION SEER 13.00 2 to 2.5 Tons Capacity

More information

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, 7.7 HSPF Three Phase, Packaged Heat Pump 3-5 Ton Units WARRANTY

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, 7.7 HSPF Three Phase, Packaged Heat Pump 3-5 Ton Units WARRANTY TECHNICAL SPECIFICATIONS Q6SD Series 13 SEER, 7.7 HSPF Three Phase, Packaged Heat Pump 3-5 Ton Units The Q6SD Series packaged units are high efficiency self contained cooling and heating units that can

More information

R6GN Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Gas/Electric Units with R-410A WARRANTY

R6GN Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Gas/Electric Units with R-410A WARRANTY TECHNICAL SPECIFICATIONS R6GN Series Single Packaged Gas/Electric Units with R-410A R6GN 10.8 EER Commercial System 12½ and 15 Ton Units These units offer flexibility in the replacement market. The 12½

More information

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, 7.7 HSPF Three Phase, Packaged Heat Pump 3-5 Ton Units WARRANTY

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, 7.7 HSPF Three Phase, Packaged Heat Pump 3-5 Ton Units WARRANTY TECHNICAL SPECIFICATIONS Q6SD Series 13 SEER, 7.7 HSPF Three Phase, Packaged Heat Pump 3-5 Ton Units The Q6SD Series packaged units are high efficiency self contained cooling and heating units that can

More information

P7RD-A Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner

P7RD-A Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner TECHNICAL SPECIFICATIONS P7RD-A Series Single Packaged Air Conditioner P7RD-A 13 SEER, R-410A 2 thru 5 Ton Units Cooling: 24,000 to 56,000 Btuh The P7 Series single packaged air conditioners are high efficiency

More information

AFGP12B. Features. Efficiency: 12 SEER 80% AFUE. Warranty: 10-year limited compressor 10-year limited heat exchanger 5-year limited components

AFGP12B. Features. Efficiency: 12 SEER 80% AFUE. Warranty: 10-year limited compressor 10-year limited heat exchanger 5-year limited components AFGP12B Gas/Electric Package Unit Features Shipped for horizontal applications; easily converted to downshot Side-by-side horizontal discharge Standard thermostatic expansion valve Crimp-Tite weld-free

More information

CPC Commercial. 15- & 20-Ton, Three-Phase Packaged Air Conditioner. 20-Ton Cooling Capacity: 240,000 BTU/h

CPC Commercial. 15- & 20-Ton, Three-Phase Packaged Air Conditioner. 20-Ton Cooling Capacity: 240,000 BTU/h CPC Commercial 15- & 20-Ton, Three-Phase Packaged Air Conditioner 15-Ton Cooling Capacity: 180,000 BTU/h 20-Ton Cooling Capacity: 240,000 BTU/h Contents Nomenclature...2 Product Features...3 Product Specifications...4

More information

P3RC-12 SEER 2 Ton thru 4 Ton Units Cooling: 23,800 to 48,000 Btuh

P3RC-12 SEER 2 Ton thru 4 Ton Units Cooling: 23,800 to 48,000 Btuh TECHNICAL SPECIFICATIONS P3R(A,C) Series Single Packaged Air Conditioner, Single Phase P3RA-10 SEER 2 thru 5 Ton Units Cooling: 24,000 to 59,000 Btuh P3RC-12 SEER 2 Ton thru 4 Ton Units Cooling: 23,800

More information

GV Series High Efficiency Geothermal/Water Source Packaged Step-Capacity Heat Pump R-410A

GV Series High Efficiency Geothermal/Water Source Packaged Step-Capacity Heat Pump R-410A GV Series High Efficiency Geothermal/Water Source Packaged Step- Heat Pump R-410A Ground Water Application: Water Temp 45 to 75 Ground Loop Application: Temp Range to GV Series Geothermal/Water Source

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model PPG2GI M1200 Product Line Single Packaged Gas/Electric Units 20 SEER, 81% AFUE 2-5 Ton Units Multi-Stage Cool / Two-Stage Heat The iq Drive gas/electric packaged system features

More information

Factory Option Codes L M E S P R D V F F H E

Factory Option Codes L M E S P R D V F F H E I N D O O R A I R Q U A L I T Y P R O D U C T S P E C I F I C AT I O N S ENERGY RECOVERY SYSTEM FOR L-SERIES ROOFTOP UNITS - 60 HZ Bulletin No. 10533 January 011 Supersedes October 010 800 to 600 cfm Capacity

More information

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO technical sales guide - 60Hz Taurus R Ducted Split Units UPTO HIGH AMBIENT OPERATION 52 O C Page CONTENTS Nomenclature.. 2 Description. 3 Features.. 3 Product Data. 4 Condensing Unit Cooling Performance

More information

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: 036-21323-001-B-0202 GENERAL SPECIFICATIONS OUTDOOR UNIT: Two independent refrigerant circuits Inherently protected fan motors Two independent scroll compressors V-Coil Design Exterior service port connections

More information

Operating Net Capacity BTU/h. Input BTU/h Efficiency. lbs (kg) PGR524040KGP* 23, ,000/26, /8 x 47 x 31-7/16

Operating Net Capacity BTU/h. Input BTU/h Efficiency. lbs (kg) PGR524040KGP* 23, ,000/26, /8 x 47 x 31-7/16 SOUND REFRIGERANT ENVIRONMENTALLY Product Specifications UP to 16 SEER, UP to 12.5 EER, PACKAGE GAS / ELECTRIC, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz 208/230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT

More information

A I R H A N D L E R S CB26UH-R. MERIT Series R-22 - Upflow / Horizontal P R O D U C T S P E C I F I C AT I O N S

A I R H A N D L E R S CB26UH-R. MERIT Series R-22 - Upflow / Horizontal P R O D U C T S P E C I F I C AT I O N S P R O D U C T S P E C I F I C AT I O N S A I R H A N D L E R S CB6UH-R MERIT Series R- - Upflow / Horizontal Bulletin No. 1067 April 01 Supersedes January 01 Nominal Capacity - 1.5 to 5 Tons Optional Electric

More information

PA55 10 SEER FEATURES 2 THRU 5 TON SINGLE PACKAGE AIR CONDITIONER

PA55 10 SEER FEATURES 2 THRU 5 TON SINGLE PACKAGE AIR CONDITIONER PACKAGE AIR CONDITIONER PA55 10 SEER C 2 THRU 5 TON SINGLE PACKAGE AIR CONDITIONER FEATURES CONSTRUCTED FOR DURABILITY All panels made from galvanized steel pre--coated inside and out -- using a polyester

More information

ZHA/ZHB SERIES WARNING

ZHA/ZHB SERIES WARNING Service Literature Corp. 09-L Revised 7-08 ZHA/ZHB SERIES, 4, 5 and 6 ton 0.6 to kw ZHA/ZHB06, 048, 060, 07 The ZHA/ZHB packaged electric heat pump units are available in standard cooling efficiency (06S,

More information

P6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioning, 13 SEER. 3, 4, 5 Ton Units

P6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioning, 13 SEER. 3, 4, 5 Ton Units TECHNICAL SPECIFICATIONS P6SD Series Single Packaged Air Conditioning, 13 SEER 3, 4, 5 Ton Units The P6 Series single packaged air conditioners are high efficiency self contained cooling units that can

More information

CPC Commercial. 7½- to 12½-Ton Three-Phase. up to 11.5 EER. Cooling Capacity: 90, ,000 BTU/h. Packaged Air Conditioners

CPC Commercial. 7½- to 12½-Ton Three-Phase. up to 11.5 EER. Cooling Capacity: 90, ,000 BTU/h. Packaged Air Conditioners CPC Commercial Cooling Capacity: 90,000 118,000 BTU/h 7½- to 12½-Ton Three-Phase Packaged Air Conditioners up to 11.5 EER Standard Features R-410A chlorine-free refrigerant High-efficiency scroll compressor

More information

AIR HANDLERS RBHK- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT

AIR HANDLERS RBHK- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT FORM NO. H11-516 REV. 1 Supersedes Form No. H11-516 Rev. 0 AIR HANDLERS RBHK- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT Features Versatile 4-way convertible design for upflow, downflow, horizontal

More information

GQ3RD Series. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS

GQ3RD Series. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS GQ3RD Series Single Packaged Heat Pump, Single Phase GQ3RD-13 SEER 2 thru 4 Ton Units Cooling: 24,000 to 48,000 Btuh Heating: 23,200 to 48,000 Btuh The GQ3 Series single packaged

More information

R6GP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Gas/Electric Units, with R-410A WARRANTY

R6GP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Gas/Electric Units, with R-410A WARRANTY TECHNICAL SPECIFICATIONS R6GP Series 6, 7½ and 10 Ton Packaged Gas/Electric Units, with R-410A 11.2 EER Commercial System These units are designed specifically for retrofit applications and compatibility

More information

TECHNICAL GUIDE FLEXIBLE LIGHT COMMERCIAL UNIT CHAMPION SERIES (WORLD 50 HZ) SINGLE PACKAGE COOLING UNITS D1EB036, 048 AND 060 3, 4 & 5 NOMINAL TONS

TECHNICAL GUIDE FLEXIBLE LIGHT COMMERCIAL UNIT CHAMPION SERIES (WORLD 50 HZ) SINGLE PACKAGE COOLING UNITS D1EB036, 048 AND 060 3, 4 & 5 NOMINAL TONS TECHNICAL GUIDE CHAMPION SERIES (WORLD 50 HZ) SINGLE PACKAGE COOLING UNITS D1EB036, 048 AND 060 3, 4 & 5 NOMINAL TONS FLEXIBLE LIGHT COMMERCIAL UNIT GENERAL York s Champion package units are designed to

More information

VT4BE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Heat Pump 14 SEER Residential System Ton Capacity WARRANTY

VT4BE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Heat Pump 14 SEER Residential System Ton Capacity WARRANTY TECHNICAL SPECIFICATIONS VT4BE Series R-410A High Efficiency Heat Pump 14 SEER Residential System 1.5 5 Ton Capacity The VT4BE Series now offers the choice of a heat pump that uses a more efficient and

More information

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Single stage cooling capacity control on all 0 241 models Two stage cooling capacity control on

More information

S/T Ratio. Input BTU/h

S/T Ratio. Input BTU/h SOUND REFRIGERANT ENVIRONMENTALLY PGD3 Product Specifications 13 SEER PACKAGE GAS / ELECTRIC UNIT, 2½ to 5 TONS 3 Phase, 208/230 3 60 and 460 3 60 REFRIGERATION CIRCUIT Environmentally sound R-410A refrigerant

More information

JT4BD Series 13 SEER TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, 8.0 HSPF 3 Phase Light Commercial High Efficiency, Heat Pump

JT4BD Series 13 SEER TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, 8.0 HSPF 3 Phase Light Commercial High Efficiency, Heat Pump TECHNICAL SPECIFICATIONS JT4BD Series 13 SEER 13 SEER, 8.0 HSPF 3 Phase Light Commercial High Efficiency, Heat Pump 3, 4, 5 Ton Capacities The JT4BD Series heat pump, when combined with our engineered

More information

AIR HANDLERS AIR HANDLERS. RHPN- SERIES 18 SEER featuring Earth-Friendly R-410A Refrigerant. Features

AIR HANDLERS AIR HANDLERS. RHPN- SERIES 18 SEER featuring Earth-Friendly R-410A Refrigerant. Features FORM NO. H11-528 Supersedes Form No. H11-526 Rev. 1 AIR HANDLERS AIR HANDLERS RHPN- SERIES 18 SEER featuring Earth-Friendly R-410A Refrigerant Features earth friendly refrigerant Includes an energy efficient

More information

R6GI Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

R6GI Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS TECHNICAL SPECIFICATIONS R6GI Series Single Packaged Gas/Electric Units 20 SEER 81% AFUE Multi-Stage Cool/Two-Stage Heat 2-5 Ton Single-Phase Units The iq Drive gas/electric packaged system features modulating

More information

DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS D(CE, CG) 036, 048, 060 & YTG-A-0207

DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS D(CE, CG) 036, 048, 060 & YTG-A-0207 TECHNICAL GUIDE SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS D(CE, CG) 036, 048, 060 & 072 3, 4, 5 & 6 NOMINAL TONS 10.0 SEER (3, 4, & 5 Ton), 9.0 EER (6 Ton) DESCRIPTION YORK

More information

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES FFMA Base Series Fan Coil Sizes 018 thru 037 Product Data A13417 FEATURES The FFMA Series Fan Coil unit is primarily designed for apartment applications as an upflow only indoor fan coil for split -system

More information

JT4BE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Heat Pump 14 SEER Residential System Ton Capacity WARRANTY

JT4BE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Heat Pump 14 SEER Residential System Ton Capacity WARRANTY TECHNICAL SPECIFICATIONS JT4BE Series R-410A High Efficiency Heat Pump 14 SEER Residential System 1.5 5 Ton Capacity The JT4BE Series now offers the choice of a heat pump that uses a more efficient and

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TM TECHNICAL SPECIFICATIONS Model PPH2SD Series M1200 Product Line Single Packaged Heat Pump 13 SEER, R-410A 2-5 Ton Units M1200 12 YEAR ALL PARTS LIMITED WARRANTY M1200 WITH UPGRADED WARRANTY PACKAGE

More information

14.5 SEER HEAT PUMPS. Featuring Industry Standard R-410A Refrigerant TZPL SERIES. Features Coils constructed with copper tubing and enhanced aluminum

14.5 SEER HEAT PUMPS. Featuring Industry Standard R-410A Refrigerant TZPL SERIES. Features Coils constructed with copper tubing and enhanced aluminum FORM NO. PTZ-803 Supersedes Form No. PTZ-781 Featuring Industry Standard R-410A Refrigerant TZPL SERIES Efficiencies up to 14.5 SEER/12.00 EER/8.50 HSPF Nominal Sizes 1.5 to 5 Tons [5.28 kw] to [17.6 kw]

More information

Q4SE Series Single Packaged Heat Pump, Single Phase

Q4SE Series Single Packaged Heat Pump, Single Phase TM TECHNICAL SPECIFICATIONS Q4SE Series Single Packaged Heat Pump, Single Phase Q4SE-14 SEER 2-5 Ton Units Cooling: 23,600 to 56,500 Btuh Heating: 22,200 to 55,500 Btuh The Q4SE Series single packaged

More information

S3BN Series Split System Air Conditioner 10.3 EER Commercial System 7½ and 10 Ton Capacity R-22 Refrigerant

S3BN Series Split System Air Conditioner 10.3 EER Commercial System 7½ and 10 Ton Capacity R-22 Refrigerant TECHNICAL SPECIFICATIONS S3BN Series Split System Air Conditioner 10.3 EER Commercial System 7½ and 10 Ton Capacity R-22 Refrigerant The S3BN Series of air conditioners offers exceptional performance from

More information

PRPHP14 PRODUCT SPECIFICATIONS 14 SEER HEAT PUMP PACKAGED UNIT REFRIGERANT SYSTEM CABINET CONSTRUCTION BLOWER CONTROLS INSTALLATION ACCESSORIES

PRPHP14 PRODUCT SPECIFICATIONS 14 SEER HEAT PUMP PACKAGED UNIT REFRIGERANT SYSTEM CABINET CONSTRUCTION BLOWER CONTROLS INSTALLATION ACCESSORIES PRODUCT SPECIFICATIONS 4 SEER HEAT PUMP PACKAGED UNIT FORM NO. -00 (03/207) REFRIGERANT SYSTEM Environmentally friendly R40A refrigerant Copper tubing with enhanced fin coils Internal service gauge ports

More information