FLECK STAINLESS STEEL METERS
|
|
- Hope Sanders
- 5 years ago
- Views:
Transcription
1 FLECK STAINLESS STEEL METERS HOT WATER RATED LEAD-FREE MATERIAL
2 WHY STAINLESS STEEL? BENEFITS TRULY LEAD- FREE MATERIAL RUST AND CORROSION RESISTANT EASE OF INSTALLATION AND MAINTENANCE HOT WATER APPLICATION & FEATURES Truly lead-free 316 grade stainless steel material REDUCED INVENTORY SINGLE AND MULTI-TANK SYSTEM COMPATIBILITY All-in-one electronic and mechanical flow sensing 1, 1.5 and 2 models are hot water rated to 65 C CURRENT BRASS METER PART NUMBER Brass Ref DESCRIPTION assy 1" assy 1" 20 m³ Stainless Steel Ref DESCRIPTION assy SS 1" BSP Mechanical 20 m³/ assy 1" 100 m³ assy SS 1" BSP Mechanical 100 m³ assy 1.5" 9500/2850/ assy 9500/2850/ " 40 m³ assy SS 1.5" BSP Mechanical 40 m³/ assy 9500/2850/ " 200 m³ assy SS 1.5" BSP Mechanical 200 m³ assy 2" assy 2" Standard (75 m³) assy SS 2" BSP Mechanical 75 m³/ assy 2" Extended (375 m³) assy SS 2" BSP Mechanical 375 m assy 3" Standard (240 m³) assy 3" assy SS 3 BSP Mechanical 240 m³/ assy 3" Extended (1200 m³) assy SS 3" BSP Mechanical 1200 m³ Kit assy 1" NT/NXT Kit assy 1" Stainless Steel NXT Kit assy 1.5" NT/NXT Kit assy 1.5 Stainless Steel NXT Kit assy 2" NT/NXT Kit assy 2" Stainless Steel NXT Kit assy 3" NT/NXT Kit assy 3" Stainless Steel NXT Please note The following changes will affect your meter applications: dimensions Plumbing dimensions cable assembly
3 ELECTRONIC & ELECTRO MECHANICAL CONTROLS Please note the following items ELECTRONIC Control valves configured with an electronic control AND for use with a SS meter will include the BR meter cable assembly. Control valves configured with an electronic control AND for use with a SS meter will NOT include a SS union. A SS union is NOT required when the SS meter is used with an electronic control. SS union is optional and can be purchased separately. ELECTRO MECHANICAL Control valves configured with an electro mechanical control AND for use with a SS meter will include the SS union, mechanical meter cable and cable guide. SS union IS required when the SS meter is used with an electro mechanical control. The location of this SS union in relation to the control valve and SS water meter is critical for proper operation. Install the SS union between the control valve outlet and SS meter inlet. Do not omit or substitute this special SS union, as it locates the meter dome at the correct distance from the control valve and allows re-positioning the meter dome for proper operation. See illustration below for proper installation of the SS union and SS meter. COMPARING METER DIMENSIONS Plumbing modifications required for meter updates Pipe Size Brass Overall Length Without Union Stainless Steel With Union Overall Length Difference Overall Length Difference mm mm mm mm mm Union / Ref. 1" " " " N/A N/A not needed Proper installation of the SS union and SS meter Powerhead assembly Position meter dome at 12 o clock orientation Union Valve Body
4 METER CABLE ASSEMBLY When replacing an existing electronic or electro mechanical brass meter with a stainless steel model, the meter cable will require replacement. Find the appropriate meter cable assembly from the cross reference tables below. ELECTRONIC METER CABLE ASSEMBLY CROSS REFERENCE Brass Stainless Steel Part Number DESCRIPTION Part Number DESCRIPTION Cable SE/SXT 0.75 m BR Cable 0.75 m Cable NT/NXT 2.5 m BR Cable 2.5 m Cable NT/NXT 7.7 m BR Cable 7.7 m ELECTRO MECHANICAL METER CABLE ASSEMBLY CROSS REFERENCE Pipe Size Valve Part Number For brass meters Length mm For stainless steel meters Part Number Length mm 1" " " " " " MKT-BR0-052-EN-A
5
Part Circle Rotor. New, stainless steel outer trip and its spring. (Post 5/93) Uses eight washers (# 16).
432 Catalog Number 47DR / 47DS / 47DH INTERnal Assembly Part Circle Rotor 1 2 3 4 28 6 31 8 9 7 29 5 18 New, stainless steel outer trip and its spring. (Post 5/93) Uses eight washers (# ). 11 32 33 30
More informationFLECK 2750 DOWNFLOW SERVICE MANUAL. waterpurification.pentair.com
FLECK 2750 DOWNFLOW SERVICE MANUAL waterpurification.pentair.com TABLE OF CONTENTS JOB SPECIFICATION SHEET...2 INSTALLATION...3 START-UP INSTRUCTIONS...3 3200 TIMER SETTING PROCEDURE...4 3210 TIMER SETTING
More informationFLECK 2850S SERVICE MANUAL. waterpurification.pentair.com
FLECK 2850S SERVICE MANUAL waterpurification.pentair.com TABLE OF CONTENTS JOB SPECIFICATION SHEET...2 INSTALLATION...3 START-UP INSTRUCTIONS...3 3200 TIMER SETTING PROCEDURE...4 3210 TIMER SETTING PROCEDURE...4
More informationFLECK 2850 CONTROL VALVE
FLECK 2850 CONTROL VALVE SERVICE MANUAL waterpurification.pentair.com TABLE OF CONTENTS JOB SPECIFICATION SHEET...2 INSTALLATION...3 START-UP INSTRUCTIONS...3 3200 TIMER SETTING PROCEDURE...4 3210 TIMER
More informationPre-Treatment Control Valve (Fleck 2850s) & Timer (Fleck SXT)
Operation Manual Pre-Treatment Control Valve (Fleck 2850s) & Timer (Fleck SXT) 1020 Industrial Drive, Orlinda, TN 37141 615-654-4441 sales@specialtyh2o.com 615-654-4449 fax TABLE OF CONTENTS Section 1
More informationMAR031615A 1. PABD Installation & Maintenance. Guide *Parts will differ for high pressure valves.
MAR031615A 1 PABD Installation & Maintenance Guide *Parts will differ for high pressure valves. Load Piston U-cup - Piston - U-cup Piston 1. Carefully place the u-cup over the neck of the piston. Load
More informationSPARE PARTS FOR FLECK VALVES
SPARE PARTS FOR FLECK VALVES Fleck : 4600 &5600 2 24115 S&S Kit Resid 17,00 3 18928 Piston Assy 4600/5600 Filter 33,80 24116 Piston Assy 4600/5600 30,00 27077 Piston Assy 4600 SE/5600 SXT 30,00 BR43346-E0
More informationEHD Hoods EHD EHDR EHD09
EHD Hoods EHD EHDR EHD09 EHD30 EHDR30 EHD3009 EHD36 EHDR36 EHD3609 EHD42 EHDR42 EHD4209 EHD48 EHDR48 EHD4809 EHD54 EHD3018 KEY DESCRIPTION EHD30S 1 ASSY, LINER 13199 2 ASSY, CANOPY WELDMENT 27504 3 ASSY,
More informationPre-Treatment Control Valve (Fleck 3150) & Timer (Fleck SXT)
Operation Manual Pre-Treatment Control Valve (Fleck 3150) & Timer (Fleck SXT) 1020 Industrial Drive, Orlinda, TN 37141 615-654-4441 sales@specialtyh2o.com 615-654-4449 fax TABLE OF CONTENTS Section 1 GENERAL
More informationHigh Pressure Rotating Arch Parts List Jan. 12, 2017 Rev. A
46-804-00-BK Rotating High Pressure Arch with Turbo Nozzles 46-805-00-BK High Pressure Rotating Arch Rotating High Pressure Arch with V-Jet Nozzles 46-806-00-BK Rotating High Pressure Arch with Wheel Blaster
More informationFLECK 2900S SERVICE MANUAL. waterpurification.pentair.com
FLECK 2900S SERVICE MANUAL waterpurification.pentair.com TABLE OF CONTENTS JOB SPECIFICATION SHEET 2 INSTALLATION 3 START-UP INSTRUCTIONS 3 3200 TIMER SETTING PROCEDURE 4 3210 & 3220 TIMER SETTING PROCEDURE
More informationPARAVION TECHNOLOGY, INC AIRWAY AVENUE FORT COLLINS, COLORADO REPORT NO. PR-206H-900M CABIN HEATER SYSTEM INSTALLATION INSTRUCTIONS
PARAVION TECHNOLOGY, INC. 2001 AIRWAY AVENUE FORT COLLINS, COLORADO 80524 REPORT NO. CABIN HEATER SYSTEM INSTALLATION INSTRUCTIONS BELL 206A/B HELICOPTERS Page i PR- Rev. P, 04/06/09 REVISIONS REV. DATE
More informationGF Sentry Series Infra-Red
GF Sentry Series Infra-Red Salamander Broilers Parts List Models GFIR36C GFIR36 GFIR8 GFIR60 Document Number: G_GMD_PL_IRBROILER_GFIR (Rev 5 Updated 07/6) Rating Plate Location Remove the drip tray to
More informationTIME OF COMPLIANCE: At owner s discretion or when part replacement is necessary.
52 Oliver Street Williamsport, PA. 770 U.S.A. Telephone + (877) 839-7878 (U.S. and Canada) Telephone + (570) 327-7222 (International) Fax + (570) 327-70 Email Technicalsupport@lycoming.com www.lycoming.com
More informationHM860 FLOWMETER OPERATOR S MANUAL DO NOT USE OR OPERATE THIS EQUIPMENT UNTIL THIS MANUAL HAS BEEN READ AND THOROUGHLY UNDERSTOOD
HM860 FLOWMETER OPERATOR S MANUAL DO NOT USE OR OPERATE THIS EQUIPMENT UNTIL THIS MANUAL HAS BEEN READ AND THOROUGHLY UNDERSTOOD PART NUMBER 393-008-020 Rev. C Table of Contents TABLE OF CONTENTS 393-008-020
More informationearth safe Fuel Systems for Critical Power
Point Level Sensors S100 Tank Refill Level Sensor 4/5 Point S101 Tank High level Sensor 3 Point S102 Tank Low Level Sensor 1 Point S103 Tank High Level Vent Sensor Level Transmitters S120 Tank Level Transmitter
More informationKEL DIFFERENTIAL PRESSURE FLOWMETERS
KEL DIFFERENTIAL PRESSURE FLOWMETERS Flow Pressure Level Temperature measurement monitoring control Rugged Metal Construction Flow Rate to 2000 GPM Linear Scale For Horizontal or Vertical Pipes Threaded
More informationSPIN-ON FILTERS & ELEMENTS
ABSOLUTE RATED (BETA SPIN ) & NOMINAL RATED SPIN-ON FILTERS & ELEMENTS Single and Twin Element Models Pressures to 20 psi Flows to 120 gpm APPLICATION HYDAC Spin-On Filters are for filtration of hydraulic
More informationHWB Series GENERAL PUMP. Hydraulic Drive Triplex Plunger Pump INDUSTRIAL INDUSTRIAL FEATURES
GENERAL PUMP HWB Series Hydraulic Drive Triplex Plunger Pump FEATURES INDUSTRIAL INDUSTRIAL Innovative drive design eliminates need for auxiliary hydraulic drive Forged brass manifold Built-in Pump Thermal
More informationClose-Coupled Centrifugal Pumps 316 Stainless Steel, Bronze and Cast Iron Models
316 Stainless Steel, Bronze Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain
More informationMODEL GLC PARTS MANUAL REV.1.02A
Owner s Manual Keep with machine for reference MODEL GLC PARTS MANUAL REV.1.02A CMA DISHMACHINES 12700 KNOTT AVENUE GARDEN GROVE, CALIFORNIA 92841 800-854-6417 FAX 714-8 95-2 141 MODEL GL-C Parts MANUAL
More informationTHE PERFECT CONNECTION BETWEEN ROTATING HOSES AND STATIONARY PARTS
ROTAPOINT COUPLINGS THE PERFECT CONNECTION BETWEEN ROTATING HOSES AND STATIONARY PARTS ROTAPOINT COUPLINGS WHAT IS A ROTAPOINT COUPLING? The ROTAPOINT swivel prevents torsion in the hose and extends the
More informationREPLACEMENT PROCEDURE FOR THE GEARBOX OIL FILTER
T S B D XX 0002 T E C H N I C A L S E R V I C E B U L L E T I N REPLACEMENT PROCEDURE FOR THE GEARBOX OIL FILTER 1-8 0 0-2 7 8-3 3 5 3 w w w. j c s t e e l e. c o m 2018 J.C. Steele & Sons, Inc. SAFETY
More informationECS/ECD Wall Ovens. Bezel, Single Oven Bezel, Double Oven Door. Convection Cell. Non-Convection Inside Cell
ECS/ECD Wall Ovens Bezel, Single Oven Bezel, Double Oven Door Single Oven Non-Convection Inside Cell Double Oven Convection Cell Non-Convection Cell Inside Cell ECS - BEZEL SINGLE OVEN ASSEMBLY Ref# Description
More informationTBM. Bi-Metal Thermometer
Description & Features: A general purpose, versatile 1" (25mm) to 6" (150mm) dial, 304 stainless steel thermometer Bi-metallic sensing element for reliable readings Back, bottom or adjustable angle connection
More informationNV452 Monoblock directional control valve
NV452 Monoblock directional control valve Product Features General Specifications Order Coding Open Center Load Sense Performance Data Inlet Options Spool Positioners Spool Options Auxilary Valves Lever
More informationFLECK 2815 WATER SOFTENER OR FILTER CONTROL VALVE SERVICE MANUAL
FLECK 2815 WATER SOFTENER OR FILTER CONTROL VALVE SERVICE MANUAL waterpurification.pentair.com TABLE OF CONTENTS JOB SPECIFICATION SHEET... 2 OPERATING PARAMETERS... 3 INSTALLATION... 4 START-UP INSTRUCTIONS
More informationSHURflo Close-Coupled Centrifugal Pumps
Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect
More informationType B TM Rupture Disk. Type. Solid Metal Rupture Disks. BSBsystems.com BSB.ie Visit our website for the most complete, up-to-date information
Catalog # 77-2003 Type B TM Solid Metal Rupture Disks Forward Acting Tension Loaded Disks BS&B Quick-Sert Safety Head Type B TM Rupture Disk BSBsystems.com BSB.ie Visit our website for the most complete,
More informationFLECK 2510 SERVICE MANUAL. waterpurification.pentair.com
FLECK 2510 SERVICE MANUAL waterpurification.pentair.com TABLE OF CONTENTS JOB SPECIFICATION SHEET...2 INSTALLATION...3 START-UP INSTRUCTIONS...3 3200 TIMER SETTING PROCEDURE...4 3210 TIMER SETTING PROCEDURE...4
More informationPARTS LIST. U Series Infra-Red Salamander Broiler. models. Parts & Service.
U Series Infra-Red Salamander Broiler models UIR36C UIR48 UIR36 UIR60 PARTS LIST Parts & Service T (USA & Canada): 1 800 47 6668 F (USA & Canada): 1 800 361 7745 www.garland-group.com Garland Commercial
More informationTEMPERATURE REGULATORS W91/W94 Series
Self-Operated Temperature Regulators Watson McDaniel reserves the right to change the designs and/or materials of its products without notice. 2010 Watson McDaniel Company Self-Operating Design Indicating
More informationTECHNICAL DATA. Notes: For use with Trim Charts on Pages 227b - d
April 15, 2011 Deluge Trim 227a Order Deluge Valve Separately This Trim Chart is for use with the following Viking Trim Sets Valve Size Galvanized Trim Part No. Brass Trim Part No. 3 (DN80) 14631-1 14631-2
More informationFULL RANGE PRESSURE COMPENSATING VARIABLE FLOW CONTROL
B Certificate FULL RANGE PRESSURE COMPENSATING VARIABLE FLOW CONTROL FC1 FC ISO 91:2 WIT DESIGN #2.2.1 FC1-3/ INLET (IN) FC FCB1-3/ INLET (IN) FCR1-3/ FCR1 INLET (IN) FEATURES: DIAMOND ONED SPOOL BORE
More informationHYDRAULICALLY DRIVEN PUMPS SELECTION GUIDE VERSION
HYDRAULICALLY DRIVEN PUMPS SELECTION GUIDE VERSION 1 9.09 1 TABLE OF CONTENTS PAGES HYDRAULIC PUMPS/MOTORS OVERVIEW 1-11 HYDRAULIC SUBASSEMBLY FEATURES... 12 FM5 & 8 Performance curves 13-18 Dimensional
More informationFLECK 5800 LXT DOWNFLOW/UPFLOW SERVICE MANUAL
FLECK 5800 LXT DOWNFLOW/UPFLOW SERVICE MANUAL 2013 Pentair Residential Filtration, LLC www.pentairaqua.com/pro TABLE OF CONTENTS JOB SPECIFICATION SHEET... 2 INSTALLATION... 3 START-UP INSTRUCTIONS...
More informationValves, Fittings, and Manifolds Catalog. We make things MOVE
Valves, Fittings, and Manifolds Catalog We make things MOVE We Make Things Move A forward-thinking innovator, Bimba provides industry-leading pneumatic, hydraulic and electric motion solutions that are
More informationSolenoid Valves & Accessories. Incorporating Solenoid Valves in. Custom Products. Solenoid Operated. Custom Products
PNEUMADYNE, INC. Catalog 24 Phone 763-559-177 Fax 763-559-547 Incorporating Solenoid Valves in Custom Products For over 3 years, manufacturers have relied on Pneumadyne for innovative solutions to their
More informationPerformance Data. Temperature Range. -20 o to 160 o F 26 Hg to 125 psi. C v Flow Rate (scfm) Fill Time Exhaust. Port.
Control Valves & Valve Accessories PNEUMADYNE, INC. Catalog 00 Phone 76-559-077 Fax 76-559-0547 Features Single stem design Compact size Four input options Numerous porting configurations Fully ported
More informationPressure Reducing, Differential and Back Pressure Regulating Valves Spring Loaded Dome Loaded Pilot Actuated
a Proportion-Air brand Pressure Reducing, Differential and Back Pressure Regulating Valves Spring Loaded Dome Loaded Pilot Actuated 1 Burling Valves Largest Cv per valve size - Possible smaller, more cost
More informationXtrac PARTS LIST. Euroclean MODEL /05 revised 7/09 FORM NO
Xtrac PARTS LIST Euroclean MODEL 56265301 6/05 revised 7/09 ACCESSORIES AVAILABLE BRUSH 56265340 Brush Assembly 12" ACCESSORY TOOLS 56314402 Wand Assembly w/soft and Hard Floor Tools 56265173 Wand Assembly
More informationGENERAL PUMPA member of the Interpump Group
FEATURES Innovative drive design eliminates need for auxiliary hydraulic drive HWB Series Hydraulic Drive - Triplex Plunger Pump HWB2512 & HWB2112 Forged brass manifold No scheduled maintenance required
More informationFLECK 5600SXT DOWNFLOW
FLECK 5600SXT DOWNFLOW SERVICE MANUAL www.pentairaqua.com TABLE OF CONTENTS JOB SPECIFICATION SHEET...2 INSTALLATION...3 START-UP INSTRUCTIONS/FLUSHING & CONDITIONING.4 CONTROL FEATURES...4 TIMER OPERATION...5
More informationFLECK 5800 LXT DOWNFLOW/UPFLOW SERVICE MANUAL
FLECK 5800 LXT DOWNFLOW/UPFLOW SERVICE MANUAL waterpurification.pentair.com TABLE OF CONTENTS JOB SPECIFICATION SHEET... 2 INSTALLATION... 3 START-UP INSTRUCTIONS... 4 CONTROL FEATURES... 4 CONTROL OPERATION...
More informationMOUNTING, OPERATING, TESTING & MAINTENANCE INSTRUCTIONS FOR ROTEX 5/2 INTERNAL PILOT OPERATED INLINE SINGLE SOLENOID POPPET VALVE MODEL L5006
Page 1 of 7 MOUNTING, OPERATING, TESTING & MAINTENANCE INSTRUCTIONS FOR ROTEX 5/2 INTERNAL PILOT OPERATED INLINE SINGLE SOLENOID POPPET VALVE MODEL L5006 ROTEX retains all rights to this publication. All
More informationFLECK 5600 SERVICE MANUAL. waterpurification.pentair.com
FLECK 5600 SERVICE MANUAL waterpurification.pentair.com TABLE OF CONTENTS JOB SPECIFICATION SHEET...2 INSTALLATION...3 START-UP INSTRUCTIONS...4 MODEL 5600 INSTALLATION AND START-UP PROCEDURES...4 MODEL
More informationSECTIONAL DIRECTIONAL VALVE HDS 20 SERIES. CROSS HYDRAULICS PTY LTD YELLOW CATALOGUE Page 3.84
CROSS HYDRAULICS PTY LTD YELLOW CATALOGUE Page 3.84 Material specification: Standard features: Optional features available: Symbols: P T A/B H.P.C.O. RV P 1 T 1 Weight CROSS HYDRAULICS PTY LTD YELLOW CATALOGUE
More informationKOBOLD DAA FLOW INDICATOR. User Instructions. DAA_manual_12-13
KOBOLD DAA FLOW INDICATOR User Instructions DAA_manual_12-13 DAA KOBOLD DAA FLOW INDICATOR User Instructions CAUTION: For safety reasons, please read the cautionary information located at the end of the
More informationOVAL GEAR FLOWMETER MECHANICAL MODEL 012 (½ )
INST-012M_R4 11/2012 OVAL GEAR FLOWMETER MECHANICAL MODEL 012 (½ ) INSTRUCTION MANUAL To the Owner PLEASE READ THIS SAFTEY INFORMATION CAREFULLY BEFORE USE. Read and retain this instruction manual to assist
More information* PKG denotes product is packaged in a plastic bag with header card. Other product is packaged loose.
AQUAVALVE ACCESSORIES The Tru-Design Aquavalve is the most versatile valve on the market today. A range of fittings is available to suit the variability of marine plumbing applications. These fittings
More informationBill of Materials *206EC-500-1, REV. M ITEM # P/N DESCRIPTION QTY TYP 0 *206EC-500-1, REV. M 206A/B BLEED AIR PLUMBING INST'N 1 KIT 1 NAS1149F1290P WA
Bill of Materials *206EC-500-1, REV. M ITEM # P/N DESCRIPTION QTY TYP 0 *206EC-500-1, REV. M 206A/B BLEED AIR PLUMBING INST'N 1 KIT 1 NAS1149F1290P WASHER 2 EA 2 ES00140-3 RUBBER EXTRUSION 12 IN 3 NAS43DD3-23FC
More informationIHR Series With Standard Oven ITEM NO DESCRIPTION PART # 36" 1 Top Grate Cast Iron 12" X 28" - (Old Style) 1187 N/A *** 12" Top Grate 12 x 13 1/4
1 Top Grate Cast Iron 12" X 28" - (Old Style) 1187 N/A *** 12" Top Grate 12 x 13 1/4 (Front) Open Burner 35334 3 *** 12" Top Grate 12 x 13 1/4 (Rear) Open Burner 35335 3 2 Top Grate Cast Iron 18" X 28"
More informationPARTS MANUAL. American Dish Service MODELS: ADC-44 L-R/R-L ADS CONVEYOR DISHWASHER EFFECTIVE: MAY, 2008
EFFECTIVE: MAY, 2008 ADS CONVEYOR DISHWASHER MODELS: ADC-44 L-R/R-L PARTS MANUAL 900 Blake Street Edwardsville, Kansas 66111 (913)422-3700 05/08 211-0044L-R / 212-0044R-L ADC-44 Conveyor Dishwasher 2 211-0044L-R
More informationDN 1/4" to 2 Female - Female BSP - 10 C C Max Pressure : 25 Bars Specifications : Union cap Stainless steel seat PTFE or Stainless steel disc
Size : Ends : Min Temperature : Max Temperature : DN 1/4" to 2 Female - Female BSP - 10 C + 180 C Max Pressure : 25 Bars Specifications : Union cap Stainless steel seat PTFE or Stainless steel disc Materials
More informationFor cleaning machines, parts & supplies click/visit This parts list is for machines after seiral number
PARTS LIST Advance MODELS 56264058, 56264001, 56264059, 56264060, 56264061, 56264062 This parts list is for machines after seiral number 1006184 5/94 revised 3/04 94-5 TABLE OF CONTENTS 1 DESCRIPTION
More informationOVAL GEAR FLOWMETER MECHANICAL MODEL 075 (3 )
INST-075M_R4 11/2012 OVAL GEAR FLOWMETER MECHANICAL MODEL 075 (3 ) INSTRUCTION MANUAL To the Owner PLEASE READ THIS SAFTEY INFORMATION CAREFULLY BEFORE USE. Read and retain this instruction manual to assist
More informationULTRA ACV RATIO REDUCING VALVES PATENT NUMBER: 2016/04949
ULTRA ACV RATIO REDUCING VALVES PATENT NUMBER: 2016/04949 T O T A L V A L V E S O L U T I O N S ULTRA ACV RATIO PRESSURE REDUCING VALVE (RPRV) Ratio Pressure Reducing valves have been in use in the Mining
More informationM-5000/5700 Instant Hot Water Maker
M-5000/5700 Instant Hot Water Maker Operations Manual for Strahman M-5000/5700 Unit, M-70 Spray Nozzle and Soft Seal Piston Valve Last Updated: July 1, 2009 Strahman Valves, Inc. USA Headquarters 2801
More informationTaps, Valves & Components. Section 1
Taps, Valves & Components Section 1 taps, valves & components index Index 1 SECTION PAGE sink taps 1.1-1.4 sink taps & spares 1.5 basin taps 1.6 general purpose taps & valves 1.7 flexible connectors, angle
More informationBIRM FILTERS 5000SE F 30L Q SE F 60L Q F 30L Q F 60L Q F 80L C F 100L C-16.
Birm filters Fleck BIRMCO incl. drain flow controller, not with filters 60 L (5000SE), 80100 (2750) and 200250 L (2850) yoke brass or connections incl. (5000SE & 7700) transfo 24V regular Birm delivered
More informationKEL. Heavy Duty Differential Pressure Flowmeters
Heavy Duty Differential Pressure Flowmeters measuring monitoring analyzing KEL Rugged Metal Construction Flow Rates up to 2000 GPM Linear Scales For Horizontal or Vertical s Threaded or Wafer Style s Able
More informationPROCESS & AUTOMATED VALVES
Process & utomated Valves HYDC s line of Process and utomated Valves complements our isolation valve knowhow and ability to supply high quality solutions to your valve requirements. 3-1 HV Series Inline
More informationTruck Hydraulics Auxiliary valves. Technical Information Ordering information and Drawings...60
Index Auxiliary Valves Bypass Valves and Unloading Valves for F1, F2, T1 and VP1 pumps Contents Page BPV-F1 and BPV-T1 bypass...59...59 Ordering information and Drawings...60 BPV-F1 and BPV-T1 Bypass without
More informationHelping you get the job done right the first time! Dependable Lightweight- Easy to use 12 volt Groundwater pumps.
Helping you get the job done right the first time! Dependable Lightweight- Easy to use 12 volt Groundwater pumps. Building on over 18 years in business, Proactive Environmental Products understands your
More informationFlow Meters. Installation, Operation & Maintenance Manual.
Flow Meters Installation, Operation & Maintenance Manual www.lakemonitors.com This manual is a service guide produced by the manufacturer and provides specific procedures and/or illustrations for disassembly,
More informationClean Water Made Easy
Clean Water Made Easy http://www.cleanwaterstore.com Pro-OX 2510 Manual Backwash Iron Filter Installation & Start-Up Guide Thank you for purchasing a Clean Water System! With proper installation and a
More informationSTREAMLINER M 500 cc Instructions. User Operating Manual
STREAMLINER M 500 cc Instructions User Operating Manual Lubricator Model Types STREAMLINER M (500cc Grease Lubricator) Before Use Thank you for purchasing the STREAMLINER M 500cc unit, the new electro-mechanical,
More informationblasting equipment Elcometer RCV4000 Remote Control Valve Quickly cuts off the flow of compressed air to the blast hose
Remote Control Valve Remote Control Valves are used to safely pressurise and depressurise abrasive blast machines at the blast nozzle using a deadman s handle. Quickly cuts off the flow of compressed air
More informationDN 1/4" to 2 Female - Female BSP - 10 C C Max Pressure : 25 Bars Specifications : Union cap Stainless steel seat PTFE or Stainless steel disc
Size : Ends : Min Temperature : Max Temperature : DN 1/4" to 2 Female - Female BSP - 10 C + 180 C Max Pressure : 25 Bars Specifications : Union cap Stainless steel seat PTFE or Stainless steel disc Materials
More informationTechnical Tips (April 2017) Product Information
Technical Tips (April 2017) Product Information MVE Stock Series The MVE Stock Series provides the ultimate in security for the breeding industry and is primarily used to store semen and embryos. The freezers
More informationOrganic Scavengers Fleck Model 2850 SXT Series Operation and Service Manual
Organic Scavengers Fleck Model 2850 SXT Series Operation and Service Manual www.ameriwater.com 800-535-5585 AmeriWater 3345 Stop 8 Rd. Dayton, OH 45414 PN: 98-0132B Table of Contents Page 1.0 INTRODUCTION
More informationCamlocks. Snaplock Camlock Couplings. The original Snaplock quick release coupling. Applications
Snaplock Camlock Couplings The original Snaplock quick release coupling The tried & trusted cam coupling with the high reputation of the Snaplock brand name offering additional features to our standard
More informationFluid Filters, Screens/Strainers, Filter Elements & Filter/Surge Chambers
s & /Surge Chambers 84, 845, 846 841010 103-141 0115-01036, 41-1639 41-1650 0115-010630 101-1765 101-097 07-159-1, 07-159- Material s, Strainers, Screens 41-875-X 41-883 41-884 SEE PAGE -6 FOR SURGE BOTTLES
More informationDESCRIPTION MECHANICAL FUEL PUMP FUEL FILTER HIGH PRESSURE (35-90 PSI) HIGH PRESSURE (35-90 PSI) (STEEL/INCLUDED)
Edelbrock EFI Universal Fuel Sump System - Adjustable Part #36031, 36032, 36033, 36034 INSTALLATION INSTRUCTIONS PLEASE study these instructions carefully before beginning this installation. This installation
More informationF200 Pilot Operated Pressure Regulator
F200 Pilot Operated Pressure Regulator External or Internal Pressure Registration Minimize Sudden Downstream Load Change Ideal for Fix Factor Billing Quick Response Time / High ccuracy The F200 series
More informationControl Valves & Valve Accessories
Control Valves & Valve Accessories PNEUMADYNE, INC. Catalog 400 Phone 76-559-077 Fax 76-559-0547 Stainless Steel 0- Fully Ported valve with M5 threads available- contact factory Viton is a registered trademark
More informationPre-Fabricated Flushing Bypass Assembly for Plant Applications Hero Plant DN15-150
Pre-Fabricated Flushing Bypass Assembly for Plant Applications Description Hero Plant is a pre-fabricated, flushing bypass arrangement for balance, control, isolation, and operation of plant devices. Flow
More informationFull Range Pressure Compensating Variable Flow Control
Engineering & Manufacturing Solutions Specifications: See flow chart for capacity. Rated for 3000 psi (207 bar). Weighs 7- ¾ lbs. (3.52 kg). 30-Micron Filtration Recommended. Torque to turn side lever
More informationEdelbrock EFI Universal Fuel Sump System - Adjustable Part #36031, INSTALLATION INSTRUCTIONS
Edelbrock EFI Universal Fuel Sump System - Adjustable Part #36031, 36032 INSTALLATION INSTRUCTIONS PLEASE study these instructions carefully before beginning this installation. This installation can be
More information2-Way Temperature Sensing Valves
2-Way Temperature Sensing Valves Models 2230 and 4430 Overview Model 2230/4430 is a normally-closed, 2-way valve which is opened by increasing temperature of engine cooling water, lubricating oil, high
More informationPIN & SLEEVE DEVICES
PIN & SLEEVE DEVICES line of industrial plugs and sockets are manufactured by ABL Sursum, a company well known in Europe for its quality electrical products. This major manufacturer combines the elements
More informationPRESSURE REDUCING VALVES
14.01 Part No. 536 536 WRAS APPROVED BRASS BODY WITH BSP THREADED CONNECTIONS SUITABLE FOR WATER & AIR The 536 pressure reducing valve is a economical and reliable solution for water and air applications.
More informationSeries 1, 2 & 6 Options selector. Port 4 = 1/8" NPT 5 = 1/4" NPT (Series 6* only) 7 = #10-32 UNF 8 = 1/4-28 UNF
KIP Isolation Valves Ideal for control of corrosive and aggressive media Elastomer diaphragm provides protection from aggressive, corrosive, and gritty media Isolation valves can be equipped with a low
More informationMODEL 106/206-PG POWER OPERATED GLOBE VALVE Sizes 1/2" to 8" (106-PG) 3" to 10" (206-PG) Installation, Operating and Maintenance Instructions
MODEL 106/206-PG POWER OPERATED GLOBE VALVE Sizes 1/2" to 8" (106-PG) 3" to 10" (206-PG) Installation, Operating and Maintenance Instructions DESCRIPTION: This valve is the basic component used for most
More informationVZ*19* VZ219E, VZ319E, VZ419E VZ219C, VZ319C, VZ419C
VZ219E, VZ319E, VZ419E VZ219C, VZ319C, VZ419C SPECIFICATIONS Design PN16, Two-way, Three-way and Three-way with bypass (Linear operation) Function.... Normally Closed (A-AB). [Without actuator fitted]
More informationComplete Systems & Parts Automatic Oiler & Grease Bank MADE IN THE USA
Complete Systems & Parts Automatic Oiler & Grease Bank MADE IN THE USA Lubrication Systems contents Lube Minder Automatic Oiler Why Lube Minder?..4 Lube Minder Parts and Pictures....6-7 Understanding the
More informationMetal Faucet Range. Telescopic Range - Ideal for tight spaces - see page 65. Modern design - total flow control. Easy adjust simple lever style
Metal Faucet Range High quality polished chromed brass faucet range - 3 ranges Modern Scandinavian style faucets High quality chrome finish and modern styling - see page 65 Compact Range Make the most
More informationHLP M10 HLP M10 (AFTER SERIAL # )
HLP-1502-0M10 HLP-0703-0M10 (AFTER SERIAL #15023661) PUMP OIL GRADE: SAE30W Non-Detergent PUMP OIL CAPACITY: 11 oz. BTU INPUT: 200, 000 (Vapor Only) PRESSURE NOZZLE: HLP-0703-0M10: 5.5 HLP-1502-0M10: 3.0
More informationSPLIT CYLINDRICAL ROLLER BEARINGS
SPLIT CYLINDRICAL ROLLER BEARINGS PERFORMANCE SOLUTIONS RANGE OF HOUSINGS Engineered to perform Standard support with complete housing and bearing Flange support Take up tension unit complete with housing
More informationPILOT OPERATED PRESSURE REDUCING VALVES PRV47 (Steel) PRV47I (St.Steel)
PILOT OPERATED PRESSURE REDUCING VALVES PRV47 (Steel) PRV47I (St.Steel) DESCRIPTION The PRV47 pilot operated pressure reducing valves are designed for use on steam, compressed air, nitrogen and other gases
More informationDescription & Features: Applications:
Description & Features: Most economical, all-purpose pressure gauge.5" (40mm) to 4" (00mm) sizes Friction bezel rings Black steel case Brass internals ±3-2-3% accuracy CRN registered 5 year warranty Applications:
More informationWhirlamatic UHS20. revised 2/01 FORM NO
Whirlamatic UHS20 PARTS LIST Advance MODELS 56183700(115V) 56183701(100V/OBSOLETE), 56183705(230V) This parts list is for machines after serial number 286668 revised 2/01 00-3 TABLE OF CONTENTS Whirlamatic
More informationAutomatic Changeover Medical Manifold Installation, Operation and Maintenance Manual
Automatic Changeover Medical Manifold Installation, Operation and Maintenance Manual Andersen Medical Gas 12 Place Lafitte Madisonville, LA 70447 http://www.themedicalgas.com 1-866-288-3783 Model Number:
More informationCartridge Filter Housings Nowata A Series
Cartridge Filter Housings Nowata A Series Customization May Change the Model Number Designation to B, D or F Series 1. Introduction All A series cartridge filter housings are designed for efficient liquid
More informationSECTION 7. PARTS INFORMATION
Henny Penny Model OE/OG 30/30/303 SECTION 7. PARTS INFORMATION 7-. INTRODUCTION This section identifies and lists the replaceable parts of the Henny Penny 3-Well Open Fryer. 7-. GENUINE PARTS Use only
More informationSECTION 3. PARTS INFORMATION
SECTION 3. PARTS INFORMATION 3-1. INTRODUCTION This section lists the replaceable parts of the Henny Penny Open Fryer, Electric. 3-2. GENUINE PARTS Use only genuine Henny Penny parts in your fryer. Using
More informationSIATA VALVES & CONTROLLERS VERSATILITY AND RELIABILITY FOR WATER TREATMENT WATER PURIFICATION VALVES - SIATA
SIATA VALVES & CONTROLLERS VERSATILITY AND RELIABILITY FOR WATER TREATMENT SIATA valves and controllers propose a full range of state-of-the-art solutions that simplify the process of designing, producing,
More informationW91/W94 Series TEMPERATURE REGULATORS. Self-Operated Temperature Regulators. Design & Operation W91 Non-Indicating W94 Dial Thermometer
Design & Operation W91 Non-Indicating W94 Dial Thermometer Watson McDaniel reserves the right to change the designs and/or materials of its products without notice. 2010 Watson McDaniel Company CAPILLARY
More informationDia. Installation and Service Instructions. Tub-Shower Systems 3520-B, 3521-B, 3522-B Series
Dia Tub-Shower Systems 3520-B, 3521-B, Series Installation and Service Instructions Model Number Series 3520-B... Shower Valve 3521-B... Shower System... Tub/Shower System Modifications -1.5... 1.5 gpm
More informationPAGE 1. Conveyor Ploughs
PAGE 1 Conveyor Ploughs BAM Conveyor Products specialise in the manufacture of a comprehensive range of high quality conveyor accessories and polyurethane components. Our engineering and manufacturing
More information