BIRM FILTERS 5000SE F 30L Q SE F 60L Q F 30L Q F 60L Q F 80L C F 100L C-16.
|
|
- Shannon Mathews
- 5 years ago
- Views:
Transcription
1 Birm filters Fleck BIRMCO incl. drain flow controller, not with filters 60 L (5000SE), (2750) and L (2850) yoke brass or connections incl. (5000SE & 7700) transfo 24V regular Birm delivered separately in 28,3 L (cuft) packaging gravel 3/5 mm delivered separately, weighed or 25 kg packaging riser tube with bottom distributor mounted in vessel (5000SE & 2750: 27mm / 2850: 50mm) FLECK 5000SE 5000SE F 30L Q SE F 60L Q13.54 FLECK F 30L Q F 60L Q F 80L C F 100L C F 80L C14.65 extra dome hole M F 100L C16.65 extra dome hole M20 FLECK F 30L Q F 60L Q F 80L C F 100L C F 150L C F 80L C14.65 extra dome hole M F 100L C16.65 extra dome hole M F 150L C18.65 extra dome hole M20 Fleck F 150L C F 175L C F 200L C F 225L C F 250L C F 300L C F 150L C18.65 extra dome hole M F 175L C21.60 extra dome hole M F 200L C21.60 extra dome hole M F 225L C24.69 extra dome hole M F 250L C24.69 extra dome hole M F 300L C24.69 extra dome hole M20 Supplement NBP piston No water bypass during rinse Fleck 2750 Supplement NBP piston No water bypass during rinse Fleck 2850 Supplement Extra microswitch Automatic air release valve Automatic air release valve , 1" maxivent MXV25 1 / 5
2 Birm filters Fleck BIRMCO incl. drain flow controller, not for filters 60 L (5000SE), (2750) and L (2850) transfo 24V regular Birm deliverd separately in 28,3L (cuft) packaging gravel 3/5 mm delivered separately, weighed or 25 kg packaging side piping & top distributor disassambled (2850: 50 mm/ 3150: 63 mm); bottom distributor mounted in vessel SIDE MOUNT Fleck F 150L C F 175L C F 200L C F 225L C F 250L C F 300L C24.69 Fleck F 400L C F 600L C F 400L C30.72 extra dome hole M F 600L C36.72 extra dome hole M20 Supplement No water bypass during rinse Fleck 2850 Supplement No water bypass during rinse Fleck 3150 Supplement Extra microswitch Automatic air release valve Automatic air release valve , 1" maxivent MXV25 Birm filters Siata BIRMCO incl. plastic fittings 1"F (132), 40 mm (230) Siata twinpilot timer, 5m tubing 6mm regular Birm delivered separately in 28,3L (cuft) packaging gravel 3/5 mm delivered separately, weighed or 25 kg packaging riser tube with bottom distributor mounted in vessel: 32 mm (132), 50 mm (230) SIATA STO timer 132 STO timer 132 STE timer 132 STE timer 30L Q L Q L Q L Q STO timer 230 STO timer 230 STO timer 230 STO timer 230 STE timer 230 STE timer 230 STE timer 230 STE timer 80L C L C L C14.65 extra dome hole M20 100L C16.65 extra dome hole M20 80L C L C L C14.65 extra dome hole M20 100L C16.65 extra dome hole M20 Supplement STtimer 3 pilots Supplement STEtimer 3 pilots Diaphragm valve Aquamatic K521 incl. connection kit 25 mm Diaphragm valve Aquamatic K524 incl. connection kit 40 mm 2 / 5
3 Birm filters Siata BIRMCO incl. drain flow controller 2", for L filters (except for 360: 200 & 250 L) plastic fittings 40 mm (240), 50 mm (350), 63 mm (363) Siata twinpilot, 5m tubing 6mm regular Birm delivered separately in 28,3 L (cuft) packaging gravel 3/5 mm delivered separately, weighed or 25 kg packaging side piping & top distributor disassembled 40 mm (240), 50 mm (350), 63 mm (363) bottom distributor mounted in vessel SIDE MOUNT SIATA STO timer 240 STO timer 240 STE timer 240 STE timer 80L C L C L C L C16.65 SIATA STO timer 350 STO timer 350 STO timer 350 STO timer 350 STO timer 350 STO timer 350 STE timer 350 STE timer 350 STE timer 350 STE timer 350 STE timer 350 STE timer 150L C L C L C L C L C L C L C L C L C L C L C L C24.69 SIATA STO timer 360 STO timer 360 STO timer 360 STO timer 360 STO timer 360 STO timer 360 STO timer 360 STO timer 360 STO timer 360 STO timer 360 STO timer 360 STO timer 150L C L C L C L C L C L C L C L C L C L C L C L C24.69 SIATA STO timer 363 STO timer 363 STO timer 363 STO timer 363 STE timer 363 STE timer 363 STE timer 363 STE timer 400L C L C L C30.72 extra dome hole M20 600L C36.72 extra dome hole M20 400L C L C L C30.72 extra dome hole M20 600L C36.72 extra dome hole M20 Supplement NBP STtimer 3 pilots Supplemen STEtimer 3 pilots Diaphragm valve Aquamatic K524 incl. connection kit 40 mm Diaphragm valve Aquamatic K535 incl. connection kit 50/63 mm 3 / 5
4 Birm filters Autotrol Performa BIRMCO incl. drain flow controller brass adapter BSP 1"M regular Birm delivered separately in 28,3 L (cuft) packaging gravel 3/5 mm delivered separately, weighed or 25 kg packaging riser tube 27 mm with bottom distributor mounted in vessel AUTOTROL / 440 F 30L Q / 440 F 60L Q / 740 F 30L Q / 740 F 60L Q / 760 F 30L Q / 760 F 60L Q13.54 AUTOTROL 273 NBP 263/273 No water bypass during rinse Kit microswitch (timer 400) Kit microswitch (timer 900) Diaphragm valve Aquamatic K521 incl. connection kit 25 mm Kit EV24V1/8" 4 / 5
5 Birm filters Autotrol Magnum BIRMCO incl. drain flow controller brass adapter BSP 6/4"M regular Birm delivered separately in 28,3 L (cuft) packaging gravel 3/5 mm delivered separately, weighed or 25 kg packaging TM: riser tube 50 mm with bottom distributor mounted in vessel SM: side piping & top distributor disassembled 50 mm; bottom distributor mounted in vessel MAGNUM Cv 1 1/2" Magnum Cv TM / 942 F 150L C18.65 Magnum Cv TM / 942 F 175L C21.60 Magnum Cv TM / 942 F 200L C21.60 Magnum Cv TM / 942 F 225L C24.69 Magnum Cv TM / 942 F 250L C24.69 Magnum Cv TM / 942 F 300L C24.69 Magnum Cv TM / 942 F 150L C18.65 extra dome hole M20 Magnum Cv TM / 942 F 175L C21.60 extra dome hole M20 Magnum Cv TM / 942 F 200L C21.60 extra dome hole M20 Magnum Cv TM / 942 F 225L C24.69 extra dome hole M20 Magnum Cv TM / 942 F 250L C24.69 extra dome hole M20 Magnum Cv TM / 942 F 300L C24.69 extra dome hole M20 Magnum Cv TM / 962 F 150L C18.65 Magnum Cv TM / 962 F 175L C21.60 Magnum Cv TM / 962 F 200L C21.60 Magnum Cv TM / 962 F 225L C24.69 Magnum Cv TM / 962 F 250L C24.69 Magnum Cv TM / 962 F 300L C24.69 Magnum Cv TM / 962 F 150L C18.65 extra dome hole M20 Magnum Cv TM / 962 F 175L C21.60 extra dome hole M20 Magnum Cv TM / 962 F 200L C21.60 extra dome hole M20 Magnum Cv TM / 962 F 225L C24.69 extra dome hole M20 Magnum Cv TM / 962 F 250L C24.69 extra dome hole M20 Magnum Cv TM / 962 F 300L C24.69 extra dome hole M20 MAGNUM Cv 1 1/2" SIDE MOUNT Magnum Cv SM / 942 F 150L C18.65 Magnum Cv SM / 942 F 175L C21.60 Magnum Cv SM / 942 F 200L C21.60 Magnum Cv SM / 942 F 225L C24.69 Magnum Cv SM / 942 F 250L C24.69 Magnum Cv SM / 942 F 300L C24.69 Magnum Cv SM / 962 F 150L C18.65 Magnum Cv SM / 962 F 175L C21.60 Magnum Cv SM / 962 F 200L C21.60 Magnum Cv SM / 962 F 225L C24.69 Magnum Cv SM / 962 F 250L C24.69 Magnum Cv SM / 962 F 300L C24.69 NBP Magnum CV No water bypass during rinse Supplement Valve with NHB cartridge 5 / 5
TECHNICAL SHEET AUTOTROL PERFORMA CV CONTROL VALVE - LOGIX SERIES WATER PURIFICATION VALVES - AUTOTROL
TECHNICAL SHEET AUTOTROL PERFORMA CV CONTROL VALVE - LOGIX SERIES TECHNICAL SHEET AUTOTROL PERFORMA CV CONTROL VALVE - LOGIX SERIES TIMER CHARACTERISTICS 742 TIME CLOCK Electronic time clock (chronometric)
More informationCAT231.1 PRESSURE GAUGE AND TEST TAP KIT SKID MOUNTING 220V, 50HZ, 1Ø OPERATING CONDITIONS 25 TO 100 PSI 100 F MAX IMUM TEMPERATURE SERIES METER
CAT231.1 STANDARD FEATURES TASK MASTER III - 1 ½ / 2 - FIVE CYCLE 316 STAINLESS STEEL VALVE - SIDE MOUNT SUPER FLOW KIT S ON 2, 3 & 4 SYSTEMS (SERVICE FLOW BYPASS DIAPHRAGM VALVES) ERCt ELECTRONIC TIMER
More informationCAT231.1 SHUT OFF KIT (SOK) TO PREVENT BYPASS PRESSURE GAUGE AND TEST TAP KIT SKID MOUNTING 220V, 50HZ, 1Ø
CAT231.1 STANDARD TASK MASTER III - 1 ½ VALVE 316 SS - SIDE MOUNT SERVICE FLOW BYPASS DIAPHRAGM VALVES. ERCt ELECTRONIC TIMER 100 PSI EPOXY LINED AND COATED CARBON STEEL MINERAL TANKS ACCUMATIC BRINE SYSTEM.
More informationCOMMERCIAL UST ADD WATER BULLETIN; ISSUE 1
J UST ADD WATER BULLETIN; ISSUE 1 Welcome to the premiere issue of the Just Add Water bulletin, an Osmonics publication designed to communicate important product and application information regarding our
More informationSPARE PARTS FOR FLECK VALVES
SPARE PARTS FOR FLECK VALVES Fleck : 4600 &5600 2 24115 S&S Kit Resid 17,00 3 18928 Piston Assy 4600/5600 Filter 33,80 24116 Piston Assy 4600/5600 30,00 27077 Piston Assy 4600 SE/5600 SXT 30,00 BR43346-E0
More informationUpper Distributor Prevents Loss of Resin to Service or Drain Flow Rates Up To 15 GPM. Clock is Simple to Set.
Suavizadores de Agua - Valumax Valumax Standard Features (All Units): Warranty - 10 Years on Resin Tank, Brine Tank, 5 Years on Electronics, Valves and All Other Parts Full 3/4 Flow Throughout System Upper
More informationMagnum Cv Valve Specifications. Magnum IT and Standard Configurations. imagination at work
Magnum Cv Valve Specifications Magnum IT and Standard Configurations imagination at work Specifications Flow Rates (Valve Only) Service @ 15 psi (1.03 ) drop....................... 76 (17.3 m 3 /hr) Backwash
More informationNEW CHAPTER 1 CABINET SOFTENERS ARE YOU LOOKING FOR YOUR PERSONAL SOFTENER? 1. CABINET - PERSONALISED
1. CABINET - PERSONALISED ARE YOU LOOKING FOR YOUR PERSONAL SOFTENER? Micron offers you the opportunity to assemble a personalized softener according to your needs and wishes. This softerner will make
More informationCHAPTER 1 CABINET SOFTENERS 1. CABINET - PERSONALISED ARE YOU LOOKING FOR A PERSONAL SOFTENER?
1. CABINET - PERSONALISED ARE YOU LOOKING FOR A PERSONAL SOFTENER? Micron offers you the opportunity to assemble a personalized softener according to your needs and wishes. This softerner will make you
More informationWATER FILTER - Fe, Mn, H 2 S
Technical Manual WATER FILTER - Fe, Mn, H 2 S Models: PF-OXY1 PF-OXY + 1 PF-OXY1,5 PF-OXY + 1,5 2016 erie water treatment TM-EN-PF-OXY-Rev2016.09 TABLE OF CONTENT & INSTALLATION RECORD Table of content
More informationBLAKE WATER SOLUTIONS U.S. NORTHEAST REGION DISTRIBUTION CATALOG REV 09/09
TM BLAKE WATER SOLUTIONS U.S. NORTHEAST REGION DISTRIBUTION CATALOG REV 09/09 RESIDENTIAL SOFTENER EQUIPMENT TABLE OF CONTENTS PROFESSIONAL SERIES - FLECK 5600 VALVE PREMIUM GRADE RESIN - SPECIFICATIONS
More informationCOMMERCIAL CONTROL VALVES. Magnum Control Valve
COMMERCIAL CONTROL VALVES Magnum Control Valve COMMERCIAL CONTROL VALVES Magnum Control Valve Controller Options The Pentair Water Magnum Control Valve is one of the most versatile valves on the market.
More informationClean and soft water for business needs. Commercial softening equipment. COMMERCIAL WATER SOFTENERS
Clean and soft water for business needs. Commercial softening equipment. COMMERCIAL WATER SOFTENERS Application of Commercial Water Softening Equipment Water hardness is responsible for many maintenance
More informationPRESSURE GAGES AND TEST TAPS
CAT 500.1 FRF series filters. Polyglass 100 psi vessels with top mount Task Master II 1 ½ valve and single point PVC internals. FMF series filters. Carbon steel epoxy lined and coated vessels with side
More informationAquaMatic Control Valves, Stagers and Controllers
Pentair Water is a leader in high technology flow control products and provides innovative solutions for commercial and industrial applications. AquaMatic valves, stagers and controllers are key components
More informationWATER TREATMENT COMPONENTS
POLYGLASS DOMESTIC TANK Structural Composite Pressure Vessels offer fiberglass construction for outstanding performance and durability in harsh chemical enviroments. This tanks are ideal for softeners
More informationDIAMOND LINE - AQUANue SYSTEMS with 1 LX CONTROL VALVE AND BYPASS
PRICE LIST WCLXAQ-16 SUPERSEDING PRICE LIST WCLXAQ-14 EFFECTIVE MAY 1, 2016 LANCASTER X-FACTOR DIAMOND LINE - AQUANue SYSTEMS with 1 LX CONTROL VALVE AND BYPASS SERIES 1000 - CTAIR IRON REMOVAL MODEL NO.
More informationFLECK STAINLESS STEEL METERS
FLECK STAINLESS STEEL METERS HOT WATER RATED LEAD-FREE MATERIAL WHY STAINLESS STEEL? BENEFITS TRULY LEAD- FREE MATERIAL RUST AND CORROSION RESISTANT EASE OF INSTALLATION AND MAINTENANCE HOT WATER APPLICATION
More informationCommercial Softeners
Commercial Softeners Product Index Page General System Specifications 35 Fleck Commercial Valve Configurations 36 Fleck 9500 1-1/" Systems 37 Fleck 850 1-1/" Systems 38 Fleck 3150 " Systems 39 Fleck 900
More informationFleck Fiberglass Section 9 Chloride Dealkalizers
Fleck Fiberglass Section 9 Fleck Fiberglass (*) Note: Steel tanks & Plastic Valve Nest (*PVN) systems are offered on custom quote basis Section 9 - Fleck Fiberglass Catalog 999701-NP Rev. F (05/17) Effective
More informationWATER FILTER - Fe, Mn, H 2 S
Technical Manual WATER FILTER - Fe, Mn, H 2 S Models: PF-OXY1 PF-OXY1,5 2018 erie water treatment TM-EN-PF-OXY-Rev2018.09 TABLE OF CONTENT Table of content...page 2 Warning & Safety instructions...page
More informationSECTION 1. Fleck Fiberglass Softeners. *Shown with factory SKID & Interconnecting Plumbing
SECTION 1 *Shown with factory SKID & Interconnecting Plumbing Fleck Fiberglass Softeners Section 01 Fleck Fiberglass softeners Catalog 999502 Effective 01/01/13 Section 01 Fleck Fiberglass softeners Catalog
More informationFleck Epoxy Lined Section 2 Steel Softeners
Epoxy Lined Section 2 Epoxy Lined *Shown with factory SKID & Plumbing Section 02 Epoxy Lined Catalog 999701-NP Rev. F (05/17) Effective 05/01/17 Section 2 Table of Contents Epoxy Lined Steel Softener Specifications
More informationControl Valves, Fittings and Accessories
Control Valves, Fittings and Accessories NEW WS1EE TWIN ALTERNATING CONTROL VALVE 28 gpm WS2H 125 gpm WS 250 gpm WS1.5EE WS1.5SP 70 gpm WS2EE WS2SP 115 gpm WS2EE/QC* WS2SP/QC* 125 gpm WS1.25* WS1.25CS*
More informationAquaMatic Series. A100 and A200 Stager Controls
AquaMatic Series A100 and A200 Stager Controls 2 Table of Contents Introduction To AquaMatic Series A100 and A200 Stager Controls3 Specifications 4 Applications 5 Features 6 Cycle Time Programming 7 Setting
More informationWATER FILTER - Fe, Mn, H 2 S
Technical Manual WATER FILTER - Fe, Mn, H 2 S 2015 erie water treatment TM-EN-Oxydizer-Rev2015.04 TABLE OF CONTENT Table of content...page 2 Warning & Safety instructions...page 3 Operating conditions
More information5600 Control Valve. Bypass Piping Boss Inlet & Outlet. Distributor Tube and basket. Brine Well. Brine Line. Over-Flow (Optional) $1.
Brine Well Distributor Tube and basket Safety-Cut Off (Optional) $8.00 extra Air Check Assembly Over-Flow (Optional) $1.00 extra 5600 Control Valve Gravel (Optional) Bypass Piping Boss Inlet & Outlet Brine
More informationFLECK 2850S SERVICE MANUAL. waterpurification.pentair.com
FLECK 2850S SERVICE MANUAL waterpurification.pentair.com TABLE OF CONTENTS JOB SPECIFICATION SHEET...2 INSTALLATION...3 START-UP INSTRUCTIONS...3 3200 TIMER SETTING PROCEDURE...4 3210 TIMER SETTING PROCEDURE...4
More informationControl Valves - Fleck, Autotrol, Clack, Aquamatic & Others
- Fleck, Autotrol, Clack, Aquamatic & Others Product Index Page Fleck 2510 183 Fleck 4650 Hot Water Control Valve 183 Fleck 5600, 6700 & ProFlo 184 Fleck 5800, 5800 XTR2 185 Fleck Valve Covers, 185 By-Pass
More informationproductsrange WORLD EDITION 02
productsrange GB WORLD EDITION 02 TENVIRONMENTALLY FRIENDLY PRODUC Identity, Innovation and ambition are the three pillars that have made Atlas Filtri the crown jewel of our country. A company who after
More informationControl Valves - Fleck, Autotrol, Clack, AquaMatic & Others
Control Valves - Fleck, Autotrol, Clack, AquaMatic & Others Product Index Page Fleck 2510 & 1500 Control Valves... 9-3 Fleck 4650 Hot Water Control Valve... 9-3 Fleck 5600, 6700 & ProFlo Control Valves...
More information255 Valve Specifications
255 Valve Specifications imagination at work Specifications Flow Rates (Valve Only) Service @ 15 psi (1.03 ) drop... 15.5 (3.52 m 3 /h) Backwash @ 25 psi (1.72 ) drop... 6.0 (1.36 m 3 /h) Service... Cv=3.99
More informationFLECK 2850 CONTROL VALVE
FLECK 2850 CONTROL VALVE SERVICE MANUAL waterpurification.pentair.com TABLE OF CONTENTS JOB SPECIFICATION SHEET...2 INSTALLATION...3 START-UP INSTRUCTIONS...3 3200 TIMER SETTING PROCEDURE...4 3210 TIMER
More informationSpecifications. Autotrol 255 Valve. Autotrol 255 Series Valve Specifications. Flow Rates (Valve Only) Regeneration Operation
Specifications GE Osmonics Autotrol 255 Series Valve Specifications Series Controllers Flow Rates (Valve Only) Service @ 15 psi (1.03 bar) drop 15.5 gpm (3.52 m 3 /h) Backwash @ 25 psi (1.72 bar) drop
More informationTNT SERIES WATER CONDITIONERS
TNT SERIES WATER CONDITIONERS For Commercial & Industrial Applications Apartment Buildings Boiler Water Treatment Car Washes Commercial Buildings Condominiums Factories Hospitals Laundries Mobile Home
More informationLogix Magnum IT and Cv Valves. Installation and Service Manual
Logix Magnum IT and Cv Valves Installation and Service Manual Table Of Contents 1.0 Installation Profile Summary....................................................3 2.0 Introduction to the Logix Magnum
More informationPre-Treatment Control Valve (Fleck 2850s) & Timer (Fleck SXT)
Operation Manual Pre-Treatment Control Valve (Fleck 2850s) & Timer (Fleck SXT) 1020 Industrial Drive, Orlinda, TN 37141 615-654-4441 sales@specialtyh2o.com 615-654-4449 fax TABLE OF CONTENTS Section 1
More informationControl Valves, Fittings and Accessories
Control Valves, Fittings and Accessories NOW WITH BATTERY PACK OPTION WS1EE TWIN ALTERNATING CONTROL VALVE 28 gpm WS2H 125 gpm WS 250 gpm WS1.5EE WS1.5SD/SP 70 gpm WS2EE WS2SD/SP 115 gpm WS2EE/QC* WS2SP/QC*
More informationBLAST MACHINES - SYSTEMS -
BLAST MACHINES - SYSTEMS - 10019 SYSTEM-3 System with ABSC-1028-17 litre Blast Machine THE SYSTEM-3 INCLUDES: Blast machine ABSC-1028 (17 litre), remote control system ARC-50-H, moisture separator CLEARLINE-½",
More informationFleck Top Mount Section 1 Fiberglass Softeners
Fleck Top Mount Section 1 Fleck Top Mount *Shown with factory SKID & Interconnecting Plumbing *Shown with factory SKID & Interconnecting Plumbing Section 01 Fleck Top Mount Catalog 999701-NP Rev. F (05/17)
More informationMASTER. Water Conditioning Corp. Installation and Operation Manual. MCA Combination Series Residential Units
MASTER Water Conditioning Corp. Installation and Operation Manual MCA Combination Series Residential Units February 2011 Table of Contents Page No. Topic Description 1 Model # and Packaging Packaging Information
More informationFLECK 2900S SERVICE MANUAL. waterpurification.pentair.com
FLECK 2900S SERVICE MANUAL waterpurification.pentair.com TABLE OF CONTENTS JOB SPECIFICATION SHEET 2 INSTALLATION 3 START-UP INSTRUCTIONS 3 3200 TIMER SETTING PROCEDURE 4 3210 & 3220 TIMER SETTING PROCEDURE
More informationTech Manual Powerline Filter (PF) Series
Tech Manual Powerline Filter (PF) Series Models: PF 2162 PF 2465 PF 3072 PF 3672 PF 4272 PF 4872 Page - 1 TABLE OF CONTENTS 1.0 General Information About this Manual...3 Filtration Technology...5 The Powerline
More informationFLECK 2750 DOWNFLOW SERVICE MANUAL. waterpurification.pentair.com
FLECK 2750 DOWNFLOW SERVICE MANUAL waterpurification.pentair.com TABLE OF CONTENTS JOB SPECIFICATION SHEET...2 INSTALLATION...3 START-UP INSTRUCTIONS...3 3200 TIMER SETTING PROCEDURE...4 3210 TIMER SETTING
More informationFLECK 2510 SERVICE MANUAL. waterpurification.pentair.com
FLECK 2510 SERVICE MANUAL waterpurification.pentair.com TABLE OF CONTENTS JOB SPECIFICATION SHEET...2 INSTALLATION...3 START-UP INSTRUCTIONS...3 3200 TIMER SETTING PROCEDURE...4 3210 TIMER SETTING PROCEDURE...4
More information8000 Pump Maintenance
8000 Pump Maintenance Perform Forward System Purge Before Performing Pump Maintenance Pump Must Be Removed From Enclosure To Service. Use Repair Kit P/N D3-0102 8000 Pump Removed From Enclosure Special
More informationParts & ACCESSORIES FOR LANCASTER WATER Treatment INDEX
PAGE 1 Parts & ACCESSORIES FOR LANCASTER WATER Treatment INDEX CARTRIDGE FILTER ACCESSORIES PAGE ATLAS DRAIN KIT 8 ATLAS GAUGE 8 CLEAR FLOW MOUNTING BRACKET 8 CLEAR FLOW WRENCH 8 DESIGNER FAUCET W/O AIR
More informationParts & ACCESSORIES FOR LANCASTER WATER Treatment INDEX
PAGE 1 Parts & ACCESSORIES FOR LANCASTER WATER Treatment INDEX CARTRIDGE FILTER ACCESSORIES PAGE ATLAS DRAIN KIT 8 ATLAS GAUGE 8 CLEAR FLOW MOUNTING BRACKET 8 CLEAR FLOW WRENCH 8 DESIGNER FAUCET W/O AIR
More informationSPARE PART LIST LW 300 E & LW 450 E
SPARE PART LIST LW 300 E & LW 450 E Nautico Maldives Pvt Ltd H. Oleander Hiththafinivaa Magu Male' Tel: + 960 31 52 53 Fax: + 960 32 44 96 Mobil: 00960 77 23 81 --------00960 77 88 79 E-mail: nautico@dhivehinet.net.mv
More informationTruck Hydraulics Auxiliary valves. Technical Information Ordering information and Drawings...60
Index Auxiliary Valves Bypass Valves and Unloading Valves for F1, F2, T1 and VP1 pumps Contents Page BPV-F1 and BPV-T1 bypass...59...59 Ordering information and Drawings...60 BPV-F1 and BPV-T1 Bypass without
More information2009 PRICE LIST. Prices FOB Ft. Myers, FL. Effective May 15, Subject to change without notice Suggested MODEL PORT SIZE HP RANGE
2009 PRICE LIST Prices FOB Ft. Myers, FL. Effective May 15, 2009. Subject to change without notice. INLINE FUEL CONDITIONER 2009 Suggested MODEL PORT SIZE HP RANGE US Retail Price LG-X 200 1/4" NPT or
More informationblasting equipment Elcometer RCV4000 Remote Control Valve Quickly cuts off the flow of compressed air to the blast hose
Remote Control Valve Remote Control Valves are used to safely pressurise and depressurise abrasive blast machines at the blast nozzle using a deadman s handle. Quickly cuts off the flow of compressed air
More informationAquaMatic Products. Valves, Stagers and Controllers OVERVIEW. GE Water & Process Technologies
AquaMatic Products Valves, Stagers and Controllers GE Water & Process Technologies OVERVIEW GE GE is a diversified manufacturer of high technology equipment, controls and components that purify water,
More informationIRON & MANGANESE REMOVAL FILTER INSTALLATION & OPERATING INSTRUCTIONS. Serial No :
IRON & MANGANESE REMOVAL FILTER INSTALLATION & OPERATING INSTRUCTIONS Model : Serial No : AFIM20-180.. Manufacturer and Supplier of FILTRATION & WATER TREATMENT PRODUCTS for commercial, industrial and
More informationFleck 2510 & 2510 Econominder
Fleck 2510 & 2510 Econominder Service Manual TABLE OF CONTENTS JOB SPECIFICATION SHEET...1 INSTALLATION...2 START-UP INSTRUCTIONS...2 3200 TIMER SETTING PROCEDURE...3 3210 TIMER SETTING PROCEDURE...4 3200,
More informationSIATA VALVES & CONTROLLERS VERSATILITY AND RELIABILITY FOR WATER TREATMENT WATER PURIFICATION VALVES - SIATA
SIATA VALVES & CONTROLLERS VERSATILITY AND RELIABILITY FOR WATER TREATMENT SIATA valves and controllers propose a full range of state-of-the-art solutions that simplify the process of designing, producing,
More informationFLECK 2815 WATER SOFTENER OR FILTER CONTROL VALVE SERVICE MANUAL
FLECK 2815 WATER SOFTENER OR FILTER CONTROL VALVE SERVICE MANUAL waterpurification.pentair.com TABLE OF CONTENTS JOB SPECIFICATION SHEET... 2 OPERATING PARAMETERS... 3 INSTALLATION... 4 START-UP INSTRUCTIONS
More informationPre-Treatment Control Valve (Fleck 3150) & Timer (Fleck SXT)
Operation Manual Pre-Treatment Control Valve (Fleck 3150) & Timer (Fleck SXT) 1020 Industrial Drive, Orlinda, TN 37141 615-654-4441 sales@specialtyh2o.com 615-654-4449 fax TABLE OF CONTENTS Section 1 GENERAL
More informationAQT-56SE ELECTRONIC SERIES PROGRAMMING MANUAL CONTROL VALVES
AQT-56SE ELECTRONIC SERIES PROGRAMMING MANUAL TABLE OF CONTENTS General Residential Installation 3 AQT-56SE Keypad 4 Control Operation 5 Master Programming - Setting the Time of Day 6 - Setting the Regeneration
More informationFleck 5600SXT Upflow. Service Manual TABLE OF CONTENTS JOB SPECIFICATION SHEET
Fleck 5600SXT Upflow Service Manual TABLE OF CONTENTS JOB SPECIFICATION SHEET...1 INSTALLATION...2 START-UP INSTRUCTIONS...2 TIMER FEATURES...3 TIMER OPERATION...4 MASTER PROGRAMMING MODE CHART...5 MASTER
More informationClean Water Group. About us
water treatment components Clean Water Group CWG Group, with its own companies in more than 20 countries and distributors in more than 50 countries worldwide, is one of the largest European distributors
More informationQ= C. v P S Refer to Table 1 for part numbers and shipping weights. Accessories: Table 1: Valve Part Numbers and Specifications
1 of 9 1. DESCRIPTION The Viking Flow Control Valve is a quick opening, differential diaphragm flood valve with a spring loaded floating clapper. The Flow Control Valve can be used to facilitate manual
More informationAQT-275 SERIES SERVICE MANUAL CONTROL VALVES
AQT-275 SERIES CONTROL VALVES SERVICE MANUAL Table of Contents General Residential Installation 3 Valve Start-up Procedures 4 Regeneration Cycle Program Setting Procedures 5 Water Conditional Diagrams
More informationPRODUCT OVERVIEW FILTER UNITS
PRODUCT OVERVIEW FILTER UNITS 2018 1 SAND FILTERS IRON REMOVAL FILTERS ACTIVATED CARBON FILTERS Riser tube Riser tube Riser tube Filter gravel 2-3 mm BIRM hydroanthracite (mixed) Activated carbon Lower
More information05 Water Pressure Systems INTRODUCTION
52 05 Water Pressure Systems INTRODUCTION Pressure Controlled Diaphragm Pumps Pressure controlled diaphragm pumps provide boat owners with a fresh water system that is as easy to use as their domestic
More informationLinea 28 Mark 1. Serial Number up to VOKERA SPARE PARTS BREAKDOWN
Linea 28 Mark 1 Serial Number up to 164370001 Outer Casing 1 RIVET 5093 5 LABEL 1781 2 LOCATING CLIP R/H 1881 6 CASE 1922 3 CLIP 5230 7 LOCATING CLIP L/H 1882 4 SELF ADHESIVE ALUM SHEET 5333 1 Main Frame
More informationMVD, MV, MKV, MKL, 2161C, MXV Series
MVD, MV, MKV, MKL, 2161C, MXV Series Float-type air vent valves Technical Data Sheet WattsIndustries.com Description DUOVENT MVD and MVDR Series, MINIVENT MV and MVR Series, MICROVENT MKV, MKVR, MKL and
More informationModel 5600SXT Upflow. Service Manual. IMPORTANT: Fill in Pertinent Information on Page 3 for Future Reference
Model 5600SXT Upflow Service Manual IMPORTANT: Fill in Pertinent Information on Page 3 for Future Reference Table of Contents Job Specification Sheet... 3 Installation Instructions... 4 Start-Up Instructions...
More informationFilters, regulators, and lubricators
Filters, regulators, and lubricators 28 filters 3/8", 1/2", and 3/4" Ports Technical data Polycarbonate bowl Polycarbonate bowl guard Metal bowl Metal bowl sight glass Filter body Manual drain Auto drain
More informationCOMPACT VENTIL COMPACT VENTIL. types 21S, 22, 33 type PANEL RADIATORS COMPACT VENTIL PANEL RADIATORS COMPACT VENTIL INSTALLATION
INSTALLATION s 21S, 22, 33 11 133 117 Standard brackets dimensions in mm Invisible bracket (Monclac) 100 100 ( 11) (s 21S, 22, 33) 61 60 76 76 126 31 72 The Compact Ventil is fitted with integrated supply
More informationPerforma Valve Specifications. 263 and 268 Configurations. imagination at work
erforma Valve pecifications 263 and 268 Configurations imagination at work pecifications Flow ates (Valve Only) Logix and 900 eries Controllers ervice @ 15 psi (1.03 ) drop... 25.0 (5.7 m 3 /h) Backwash
More information3000 Series filters 3/4" and 1" Ports
38 filters 3/4" and 1" Ports Technical data Metal bowl Metal bowl sight glass Filter body Manual drain Auto drain Standard filter Coalescing filter Seals Filter baffle Aluminum Nylon Aluminum Brass + nitrile
More informationMAR031615A 1. PABD Installation & Maintenance. Guide *Parts will differ for high pressure valves.
MAR031615A 1 PABD Installation & Maintenance Guide *Parts will differ for high pressure valves. Load Piston U-cup - Piston - U-cup Piston 1. Carefully place the u-cup over the neck of the piston. Load
More informationControls and Accessories Part Number Controls and Accessories Part Number
Linea 24 Mark 1 Serial Number Up to 161380001 Controls and Accessories Part Number Controls and Accessories Part Number CLOCK - MECHANICAL 201 CLOCK - DIGITAL 202 CONVERSION KIT LPG - NG 01005225 CONVERSION
More informationINSTALLATION, OPERATING AND SERVICE MANUAL
INSTALLATION, OPERATING AND SERVICE MANUAL ECONO-mist WATER SOFTENER Demand Regeneration 7-LMC56-75B 7-LM56-75B 7-LM56-100B 7-LM56-150B 7-LM56-200B Congratulations on purchasing your new Lancaster Water
More informationSolenoid Valves. Product Information. It s all at Albion
Solenoid Valves Product Information It s all at Albion General Information SLP 2/2 WAY SOLENOID VALVE SERIES A:Product Applications. SLP 2/2 way series solenoid valves are commonly used actuators in automation
More informationTECHNICAL DATA. Viking Technical Data may be found on Style: 90 Degree Pattern (inlet to outlet)
Flow Control 500a DESCRIPTION The Viking 1-1/2 is a quick opening, differential type flood valve with a spring loaded rolling diaphragm clapper. The can be used to facilitate manual or automatic on/off
More informationAQT-56 POWERFLO SERIES SERVICE MANUAL CONTROL VALVES
AQT-56 POWERFLO SERIES SERVICE MANUAL Table of Contents Products Checking List 3 General Residential Installation Check List 4 AQT-56ST Softener Timer Control Valve Start-up Procedures 5 AQT-56FT Filter
More informationAQUAMATIC CONTROL VALVES, STAGERS AND CONTROLLERS
AQUAMATIC CONTROL VALVES, STAGERS AND CONTROLLERS BUILDING SOLUTIONS AND PARTNERSHIPS AQ Matic is a leader in high technology flow control products and provides innovative solutions for commercial and
More informationAUTOMATIC PRESSURE FILTERS TURBIDITY FILTERS ACTIVATED CARBON FILTERS IRON - MANGANESE REMOVAL FILTERS SERIES: ECF TFA TFB
AUTOMATIC PRESSURE FILTERS TURBIDITY FILTERS ACTIVATED CARBON FILTERS IRON - MANGANESE REMOVAL FILTERS SERIES: ECF TFA TFB AUTOMATIC PRESSURE FILTERS SERIES ECF ECF/542 : 0.5 m 3 /h 1.6 m 3 /h Time based
More informationQGD-20/25/30 & QGD-40/50
QGD-0/5/0 & QGD-40/50 Direct Drive Rotary Screw Air Compressor Parts Manual This manual contains important safety information and should be made available to all personnel who operate and/or maintain this
More informationSignature Series Filter Manual
Signature Series Filter Manual Installation / Operation Manual Fully Automatic Water Filter Filter Specifications...Page 3 Installation Requirements...Page 4 Installation Procedures...Page 5 Error Codes...Page
More informationOwners Manual Installation Instructions. For Models PTCF PTCF PTCF
Owners Manual Installation Instructions For Models PTCF-5600-09 PTCF-5600-10 PTCF-5600-13 Table of Contents Page 2 Subject Page PURE TECH 2000 Diagram 4 Job Specification Sheet 5 System Overview 6 Pre
More informationWATER SOFTENER SEMI AUTOMATIC INSTALLATION & OPERATING INSTRUCTIONS. Serial No :
WATER SOFTENER SEMI AUTOMATIC INSTALLATION & OPERATING INSTRUCTIONS Model : Serial No : SAS0922.. Manufacturer and Supplier of FILTRATION & WATER TREATMENT PRODUCTS for commercial, industrial and residential
More informationTECHNICAL DATA 1-1/2 (dn40)
July 1, 2011 Deluge Valves 209a DESCRIPTION The Viking Model E-3 1-1/2 Deluge Valve is a quick-opening, differential type flood valve with a rolling diaphragm clapper. The deluge valve is used to control
More informationCATALOG OF REPLACEMENT PARTS
CATALOG OF REPLACEMENT PARTS Water Softeners WS-40 WS-80 WS-55 WS-500 WS-C206 WS-C208 WS-P213 A product of HOBART 701 S. RIDGE AVENUE TROY, OHIO 45374-0001 FORM 43276 (November 2013) F-43276 (November
More informationFLECK 5800 LXT DOWNFLOW/UPFLOW SERVICE MANUAL
FLECK 5800 LXT DOWNFLOW/UPFLOW SERVICE MANUAL 2013 Pentair Residential Filtration, LLC www.pentairaqua.com/pro TABLE OF CONTENTS JOB SPECIFICATION SHEET... 2 INSTALLATION... 3 START-UP INSTRUCTIONS...
More informationEAFM, EAFC & EAFN Filters Installation and Operating Instructions
EAFM, EAFC & EAFN Filters Installation and Operating Instructions Please pass these instructions on to the operator of this equipment. WARNING For proper operation, the inlet water pressure must be between
More information» Principals of Spider -Valve VA series
» Principals of Spider -Valve VA series 2-way-Spider -Valve, direct actuated, NC In the rest position the leaf spring pushes the disk armature with sealing element against the valve seat. The medium supports
More informationDirect/Factory Mounting Valve Set
Generated: 29th April 2018 Marflow Hydronics 1 Dimensions DN 15/20 A 243 B 137 C 115 D 3/4 Euroconus d 40 E 30.2 Generated: 29th April 2018 Marflow Hydronics 2 Product Variations NX-EVO-X-X-03 Part No:
More informationFLECK 5600 SERVICE MANUAL. waterpurification.pentair.com
FLECK 5600 SERVICE MANUAL waterpurification.pentair.com TABLE OF CONTENTS JOB SPECIFICATION SHEET...2 INSTALLATION...3 START-UP INSTRUCTIONS...4 MODEL 5600 INSTALLATION AND START-UP PROCEDURES...4 MODEL
More informationHYDRAULIC BREAKER HAMMER HB 50 J HAMMER HB 50 L HAMMER HB 50 U
PARTS MANUAL ver. 1.1 PMHB50ENG.051011 HYDRAULIC BREAKER HB 50 J HB 50 L HB 50 U Serial No. TRK500005-UP TRK510005-UP TRK520005-UP TABLE OF CONTENTS 1. Housing unit 50J... 4 2. Housing unit 50L... 6 3.
More informationSolenoid Operated Block Valves A2800 Series
Solenoid Operated Block Valves A2800 Series Installation and Parts Liquid Controls An IDEX Fluid & Metering Business Installation: M400-40 Table of Contents Introduction Safety Procedures... 3 A2800 Series
More informationDK Series Pneumatic Diaphragm Valves Product Data Sheet
1" through 2-1/2" 1/2" and 3/4" < STANDARDS > ASTM D1784 ASTM D1785 ASTM D4101 ASTM D3222 ASTM D2464 ASTM D2466 ASTM D2467 ASTM F441 ASTM F437 ASTM F439 ASTM F1498 IPEX DK Series are the ideal solution
More informationDWS 41. Installation Data 44 Performance Specs DWS & DW-PRV Series
IRRIGATION Title Description Details Page Intro 3 2000 Series 4 Model 2000 Solenoid 1 3 12 Model 2000 Solenoid 4 8 15 Model 2030 Low Power Solenoid 1 3 17 Model 2030 Low Power Solenoid 4 8 19 Model 2160
More informationFLECK 5800 LXT DOWNFLOW/UPFLOW SERVICE MANUAL
FLECK 5800 LXT DOWNFLOW/UPFLOW SERVICE MANUAL waterpurification.pentair.com TABLE OF CONTENTS JOB SPECIFICATION SHEET... 2 INSTALLATION... 3 START-UP INSTRUCTIONS... 4 CONTROL FEATURES... 4 CONTROL OPERATION...
More informationONE. Cartridge Tank Filters
ONE Cartridge Tank Filters TABLE OF CONTENTS Preinstallation Instructions....3 EF-835-1 Bypass Installation...3 Installation Instructions....5 Cartridge Replacement Instructions....7 EF-835-2 Installation
More information6600/6700 INDUSTRIAL ELECTRONIC USED ON RESIDENTIAL VALVE L ÉLECTRONIQUE INDUSTRIELLE AU SERVICE
INDUSTRIAL ELECTRONIC USED ON RESIDENTIAL VALVE Adjustable regeneration cycles. Up flow or down flow brining. 6600/6700 Modular conception simplifies the disassembly and the maintenance. Monitored by a
More informationFleck 2510 Manual Sediment Filter Installation & Start-Up Guide
Clean Water Made Easy www.cleanwaterstore.com Fleck 2510 Manual Sediment Filter Installation & Start-Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine
More informationVol. l. Empty wt. kg. Dia. Vol l. Empty wt. Dia.
Container Assemblies and Connections Multiple Part Numbers Container Assemblies and Connections ISS CG 2 25 bar Container Assemblies Assy Part no. Container Assembly Valve Empty wt. kg Vol. l Dia. Cont.
More information