Control Valves, Fittings and Accessories
|
|
- Poppy Mills
- 6 years ago
- Views:
Transcription
1 Control Valves, Fittings and Accessories NEW WS1EE TWIN ALTERNATING CONTROL VALVE 28 gpm WS2H 125 gpm WS 250 gpm WS1.5EE WS1.5SP 70 gpm WS2EE WS2SP 115 gpm WS2EE/QC* WS2SP/QC* 125 gpm WS1.25* WS1.25CS* 4 gpm WS1.25EE* WS1.25SP* 4 gpm WS1.25TC* 4 gpm WS1* WS1CS* WS1EE* WS1SP* WS1TC* *valves shown with optional accessories
2 WS1EE TWIN ALTERNATING CONTROL VALVE Water Specialist Control Valve Service flow 28 gpm, backwash flow 15 gpm with meter and bypass installed Solid state microprocessor with easy access front panel settings Front panel display for time of day, days until next regeneration, volume remaining, current flow rate and total volume used (Totalizer), and Tank in Service Indication Four methods to initiate regeneration; meter immediate, meter delayed, time clock delayed or pressure differential Optional double backwash feature offers optimum regeneration, cleaning ability and efficiency Adjustable cycle times with 6-cycle control delivers controlled backwash, downflow brining/slow rinse, second backwash, fast rinse, refill and downflow service Coin Cell Lithium battery back-up with a 8 hour carry over Backwash and brining ability to 21 diameter tanks regeneration 12-volt output AC Adapter provides safe and easy installation Treated/Soft water post fill and regeneration cycles Patented one piece expanding seal spacer stack assembly U.S. Patent 6,402,944 Patented linearly reciprocating piston operation U.S. Patent 6,444,127 Reliable and proven DC drives
3 Water Specialist 1 EE Twin Alternating Specifications Inlet/Outlet Fittings... ¾" to 1.5 NPS Cycles... up to 6 Valve Material... Noryl (1) or equivalent Regeneration... downflow Flow RateS psi drop (includes bypass and meter) gpm 25 psi drop gpm Cv Service Cv Backwash Operating Pressures Minimum/Maximum psi 125 psi Operating Temperatures Minimum/Maximum... 40º 110º F Meter Accuracy... ± 5% Flow Rate Range gpm Gallon Range ,500,000 gallons Totalizer ,999,000 gallons Dimensions & Weight Distributor Pilot " OD Pipe (¾" NPS) Drain Line... ¾ or 1 Male NPT Brine Line... /8 or ½ OD Poly Tube Compression Mounting Base... 2 ½ - 8 NPSM Height From Top Of Tank... 7 /8 Weight lbs. Electrical Specifications AC Adapter U.S. International Supply Voltage V AC... 20V AC Supply Frequency Hz Output Voltage Output Current Tank Applications Water Softener diameter Water Filter (2) diameter Cycles of Operation (Softener / Filter downflow) Softener Filter Cycle Range of time in minutes 1. Backwash 1 st Backwash Regenerate Draw/Slow Rinse Backwash 2 nd Fast Rinse Rinse Regenerant Refill or off 6. Service (downflow) Options: Backwash Filter, Bypass, Weather Cover Compatible with the following typical concentration of regenerants or chemicals: Sodium chloride, potassium chloride, potassium permanganate, sodium bisulfite, chlorine and chloramines 1. Noryl is a trademark of Sabic Innovative Plastics IP B.V. Company 2. Filter tank size 10 gpm of backwash per square foot of bed area U.S. Patents: 6,402,944 6,444,127
4 1 Water Specialist Valve Specifications SPECIFICATIONS WS1 WS1CS WS1EE WS1SP WS1TC 15 psi drop 25 psi drop (includes meter and bypass) (includes meter and bypass) Tank Applications: Softener Filter (1) Inlet/Outlet Fitting Connections NPT Sweat Solvent 4-1 SharkBite NPT Sweat Solvent 4-1 SharkBite NPT Sweat Solvent 4-1 SharkBite Valve Material Cycles Regeneration Noryl (2) /Upflow Noryl (2) Noryl (2) Operating Pressures Operating Temperatures Meter: Flow Rate Range Volume Range (gallons) Totalizer ,000 gallons ,500,000 gallons Not Applicable Distributor Pilot O.D. Pipe 4 NPS O.D. Pipe 4 NPS O.D. Pipe 4 NPS Drain Line Connection Brine Line Connection 4 Male NPT Standard 8 or 1 2 O.D. Poly Tube Compression 4 Male NPT Standard 8 or 1 2 O.D. Poly Tube Compression 4 Male NPT Standard 8 or 1 2 O.D. Poly Tube Compression Mounting Base Options NPSM NPSM NPSM Height From Top of Tank Shipping Weight 4.5 lbs. 4.5 lbs. 4.5 lbs. Electrical: Supply Voltage Supply Frequency Output Voltage Output Current 120V AC 1. Filter tank size 10 gpm of backwash per square foot of bed area 2. Noryl is a trademark of Sabic Innovative Plastics IP B.V. Company. Acquired by use of external drain line flow control 120V AC or 6AA NMHB 120V AC
5 1.25 Water Specialist Valve Specifications WS1.25 WS1.25CS 4 gpm (includes meter and bypass) 2 gpm () WS1.25EE WS1.25SP 4 gpm (includes meter and bypass) 2 gpm () 4 gpm 2 gpm () WS1.25TC 6-24 diameter NPT Sweat Solvent 4-1 SharkBite Noryl (2) 6-24 diameter NPT Sweat Solvent 4-1 SharkBite Noryl (2) 6-24 diameter NPT Sweat Solvent 4-1 SharkBite Noryl (2) gpm 20-50,000 gallons 1.2 O.D. Pipe 1 NPS 4 Male NPT Standard 8 or 1 2 O.D. Poly Tube Compression gpm 20-1,500,000 gallons 1.2 O.D. Pipe 1 NPS 4 Male NPT Standard 8 or 1 2 O.D. Poly Tube Compression Not Applicable 1.2 O.D. Pipe 1 NPS 4 Male NPT Standard 8 or 1 2 O.D. Poly Tube Compression NPSM NPSM NPSM lbs. 4.5 lbs. 4.5 lbs. 120V AC 120V AC or 6AA NMHB 120V AC Valves shown with optional bypass.
6 1.5 & 2 Water Specialist Valve Specifications SPECIFICATIONS 15 psi drop 25 psi drop Tank Applications: Softener Filter (1) Inlet/Outlet Fitting Connections Valve Material Cycles Regeneration Operating Pressures Operating Temperatures Meter: Flow Rate Range Volume Range (gallons) Totalizer Distributor Pilot Drain Line Connection Brine Line Connection 70 gpm 52 gpm WS1.5EE WS1.5SP 12-0 diameter 12-0 diameter 115 gpm 80 gpm WS2EE WS2SP diameter 12-6 diameter 1.5 Female NPT 2 Female NPT Lead Free Brass gpm 20-1,500,000 gallons 1.90 O.D. Pipe 1.5 NPS 1.25 Female NPT with 4 Male NPT Standard 4 Female NPT 1 2 O.D. Poly Tube Compression Lead Free Brass Mounting Base Options 4-8 UN 4-8 UN gpm 20-1,500,000 gallons 1.90 O.D. Pipe 1.5 NPS 1.5 Female NPT 1 Male NPT elbow 4 x 1 Solvent elbow 1 2 O.D. Poly Tube Compression Height From Top of Tank Shipping Weight with Meter 21 lbs. 29 lbs. Electrical: Supply Voltage Supply Frequency Output Voltage Output Current 120V AC or 6AA NMHB 1. Filter tank size 10 gpm of backwash per square foot of bed area 120V AC or 6AA NMHB
7 2 & Water Specialist Valve Specifications WS2EE/QC WS2SP/QC WS2H WS 125 gpm 85 gpm 125 gpm (includes meter) 125 gpm 250 gpm 220 gpm diameter 12-6 diameter 18-6 diameter diameter 2 Female NPT 2 Female NPT/ 2.5 Groove Lock Lead Free Brass Lead Free Brass Up to diameter (2) 18-6 diameter Female NPT Lead Free Brass Up to gpm 20-1,500,000 gallons 2.75 O.D. Pipe 2 NPS gpm ,000 gallons 2.75 O.D. Pipe 2 NPS 1.5 Female NPT 2 Female NPT/ 2.5 Groove Lock.5-50 gpm ,000 gallons.5 O.D. Pipe NPS Female NPT 1 Male NPT elbow 4 x 1 Solvent elbow 1 2 O.D. Poly Tube Compression Quick Disconnect 4-8 UN 6 Flange Side Mount with 4-8 UN QC Base is 11.2 with 6 Flange QC Base is Male NPT elbow 4 x 1 Solvent elbow Quick Disconnect 4-8 UN 6 Flange Side Mount 1 Male NPT elbow 4 x 1 Solvent elbow Quick Disconnect 6 Flange Side Mount with 4-8 UN QC Base is 11.5 with 6 Flange QC Base is 11.6 with 6 Flange QC Base is lbs. 50 lbs. 57 lbs. (no meter) 120V AC or 6AA NMHB 120V AC 24V AC 750 ma 120V AC 24V AC 750 ma diameter with standard injectors, to 96 with Brine Pump Valves shown with optional accessories.
8 1 & 1.25 Control Valve Fittings and Accessories 1 PVC Male NPT Elbow Assembly ¾ x 1 PVC Solvent Elbow Assembly 1 Brass Sweat Assembly LF Order No. V007 Order No. V Order No. V007-02LF ¾ Brass Sweat Assembly LF 1 Plastic Male NPT Assembly 1.25 Plastic Male NPT Assembly Order No. V007-0LF Order No. V Order V No. V Plastic Male BSPT Assembly 1.25 & 1.5 PVC Solvent Assembly 1.25 Plastic Male BSPT Assembly Order No. V Order No. V Order No. V & 1.5 Brass Sweat Assembly LF ¾ SharkBite Assembly 1 SharkBite Assembly Order No. V007-09LF Order V No. V Order No. V007-1
9 1 & 1.25 Control Valve Fittings and Accessories ¾ Plastic Male BSPT Assembly ¾ John Guest QC Elbow Assembly 1 PVC Male BSPT Elbow Assembly Order No. V Order No. V Order No. V John Guest Straight QC Bypass 1 Straight DLFC w/silencer Order No. V Order No. V006 Order No. V Straight DLFC without Silencer Auxiliary Microswitch Kit WS1 Series Microswitch Assembly Order No. V Order No. V009 Order No. V014 WS2 Auxiliary Switch Kit Vertical 90 Adapter Kit Twin Interconnect Kit Order No. V017 Order No. V Order No. V
10 1 & 1.25 Control Valve Fittings and Accessories 1 & 1.25 Motorized Alternating Valve 1 & 1.25 No Hard Water Bypass Valve Order No. V069FF-01 F x F Order No. V070FF F x F 1 & 1.25 Motorized Alternating Valve 1 & 1.25 No Hard Water Bypass Valve Order No. V069MM-01 M x M Order No. V070FM F x M
11 1.5 and 2 Control Valve Accessories 1.5 Motorized Alternating Valve 1.5 No Hard Water Bypass Valve Order No. V071 NPT Order No. V071BSPT BSPT Order No. V097 NPT Order No. V097BSPT BSPT 2.0 Motorized Alternating Valve 2.0 No Hard Water Bypass Valve Order No. V076 NPT Order No. V076BSPT BSPT Order No. V098 NPT Order No. V098BSPT BSPT
12 Control Valve Accessories Motorized Alternating Valve No Hard Water Bypass Valve Order No. V08 NPT Order No. V08BSPT BSPT Order No. V099 NPT Order No. V099BSPT BSPT Other Accessories Weather Covers Wrench V Order No. V175WC-W White Order No. V175WC-A Almond Order No. V DURAFORM LANE WINDSOR, WISCONSIN USA phone (608) fax (608) sales /customer service fax (800) Form No /2/201
Control Valves, Fittings and Accessories
Control Valves, Fittings and Accessories NOW WITH BATTERY PACK OPTION WS1EE TWIN ALTERNATING CONTROL VALVE 28 gpm WS2H 125 gpm WS 250 gpm WS1.5EE WS1.5SD/SP 70 gpm WS2EE WS2SD/SP 115 gpm WS2EE/QC* WS2SP/QC*
More informationwd-2
wd-2 wd-4 wd-5 wd-6 wd-7 wd-8 wd-9 wd-10 wd-11 wd-12 wd-13 Part # Tank Size ( DxH ) Media Volume (ft3) Service Flow Rate (GPM) WD SP35BFJCT 10 x44 1.0 6.0 WD SP46BFJCT 10 x54 1.5 9.0 WD SP56BFJCT 10 x54
More informationCommercial Softeners
Commercial Softeners Product Index Page General System Specifications 35 Fleck Commercial Valve Configurations 36 Fleck 9500 1-1/" Systems 37 Fleck 850 1-1/" Systems 38 Fleck 3150 " Systems 39 Fleck 900
More informationSpecifications. Autotrol 255 Valve. Autotrol 255 Series Valve Specifications. Flow Rates (Valve Only) Regeneration Operation
Specifications GE Osmonics Autotrol 255 Series Valve Specifications Series Controllers Flow Rates (Valve Only) Service @ 15 psi (1.03 bar) drop 15.5 gpm (3.52 m 3 /h) Backwash @ 25 psi (1.72 bar) drop
More information255 Valve Specifications
255 Valve Specifications imagination at work Specifications Flow Rates (Valve Only) Service @ 15 psi (1.03 ) drop... 15.5 (3.52 m 3 /h) Backwash @ 25 psi (1.72 ) drop... 6.0 (1.36 m 3 /h) Service... Cv=3.99
More informationSuperior Water And Air OWNER S MANUAL Model 32-CL770 & 48-CL770
Superior Water And Air 80-974-9090 800-974-7638 OWNER S MANUAL Model 32-CL770 & 48-CL770 GENERAL INFORMATION Congratulations on having purchased a quality and well built Superior Water Softener. On a normal
More informationWater Specialist WS1 and WS1.25 Drawings and Service Manual 1 Control Valve Series Model: WS Control Valve Series Model: WS1.
Water Specialist WS and WS.25 Drawings and Service Manual Control Valve Series Model: WS.25 Control Valve Series Model: WS.25 Operation and Instruction Manual for OEM Only. Please Note: This operation
More informationWater Specialist 1 Control Valve Series Model: WS1TC 1.25 Control Valve Series Model: WS1.25TC
Water Specialist Control Valve Series Model: WSTC.25 Control Valve Series Model: WS.25TC Operation and Instruction Manual for OEM Only. Please Note: This operation and instruction manual is for the training
More informationWater Specialist 1 Control Valve Series Model: WS1CS 1.25 Control Valve Series Model: WS1.25CS
Water Specialist 1 Control Valve Series Model: WS1CS 1.25 Control Valve Series Model: WS1.25CS Operation and Instruction Manual for OEM Only. Please Note: This operation and instruction manual is for the
More informationWater Specialist WS1 and WS1.25 Drawings and Service Manual 1 Control Valve Series Model: WS Control Valve Series Model: WS1.
Water Specialist WS1 and WS1.25 Drawings and Service Manual 1 Control Valve Series Model: WS1 1.25 Control Valve Series Model: WS1.25 Operation and Instruction Manual for OEM Only. Please Note: This operation
More informationWater Specialist 1 Control Valve Series Model: WS1CI 1.25 Control Valve Series Model: WS1.25CI
Water Specialist 1 Control Valve Series Model: WS1CI 1.25 Control Valve Series Model: WS1.25CI Operation and Instruction Manual for OEM Only. Please Note: This operation and instruction manual is for the
More informationWater Specialist 1 Control Valve Series Model: WS1EI 1.25 Control Valve Series Model: WS1.25EI
Water Specialist Control Valve Series Model: WSEI.25 Control Valve Series Model: WS.25EI Operation and Instruction Manual for OEM Only. Please Note: This operation and instruction manual is for the training
More informationCOMMERCIAL / INDUSTRIAL WATER SOFTENERS
COMMERCIL / INDUSTRIL WTER SOFTENERS When performance & value matters. CONTROL VLVES SPECIFICTIONS EWS1 EWS1.5 EWS2QC Service @ 15 psi drop ackwash @ 25 psi drop 27 gpm (includes meter & bypass) 27 gpm
More informationWater Specialist WS2H and WS3 Control Valve Drawings and Service Manual
Water Specialist WSH and WS Control Valve Drawings and Service Manual HYDROCARBONS SUCH AS KEROSENE, BENZENE, GASOLINE, ETC., MAY DAMAGE PRODUCTS THAT CONTAIN O-RINGS OR PLASTIC COMPONENTS. EXPOSURE TO
More informationWater Specialist 1 & 1.25 Motorized Alternating Valve
Water Specialist 1 & 1.25 Motorized Alternating Valve Allows for twin alternating system Low voltage drive assembly controlled by valves circuit board Utilizes WS1 and WS1.25 Control Valve Fittings Full
More informationWS1 & 1.25 Man u al. Introduction. The following general warnings and the specifications in Table 1 must appear in the OEM s System Manual.
Page 4 WS1 & 1.25 Man u al Introduction This manual is about a control valve to be used on water softeners or water filters. The manual is designed to aid water treatment equipment manufacturers in the
More informationWater Specialist 1 Control Valve Series Model: WS Control Valve Series Model: WS1.25
Water Specialist Control Valve Series Model: WS.25 Control Valve Series Model: WS.25 Operation and Instruction Manual for OEM Only. Please Note: This operation and instruction manual is for the training
More informationWater Specialist 1.5, 2 and 2 QC Control Valve Drawings and Service Manual
Water Specialist.5, and QC Control Valve ings and Service Manual HYDROCARBONS SUCH AS KEROSENE, BENZENE, GASOLINE, ETC., MAY DAMAGE PRODUCTS THAT CONTAIN O-RINGS OR PLASTIC COMPONENTS. EXPOSURE TO SUCH
More informationMotorized Alternating Valve
Motorized Alternating Valve Installation Guide for EE and EI V3069FF 1 and 1.25 V3069MM 1 and 1.25 V3071 or V3071BSPT 1.5 V3076 or V3076BSPT 2 V3069MM 1 and 1.25 V3069FF 1 and 1.25 View from top C A B
More information5600 Control Valve. Bypass Piping Boss Inlet & Outlet. Distributor Tube and basket. Brine Well. Brine Line. Over-Flow (Optional) $1.
Brine Well Distributor Tube and basket Safety-Cut Off (Optional) $8.00 extra Air Check Assembly Over-Flow (Optional) $1.00 extra 5600 Control Valve Gravel (Optional) Bypass Piping Boss Inlet & Outlet Brine
More informationWater Specialist EE Control Valve Programming and Cover Drawing Manual
Water Specialist EE Control Valve Programming and Cover Drawing Manual Page 2 EE Man u al EE Man u al Page 3 Table of Contents EE Front Cover and Drive Assembly... 4 Regeneration and Error Screens, Button
More informationPerforma Valve Specifications. 263 and 268 Configurations. imagination at work
erforma Valve pecifications 263 and 268 Configurations imagination at work pecifications Flow ates (Valve Only) Logix and 900 eries Controllers ervice @ 15 psi (1.03 ) drop... 25.0 (5.7 m 3 /h) Backwash
More informationMagnum Cv Valve Specifications. Magnum IT and Standard Configurations. imagination at work
Magnum Cv Valve Specifications Magnum IT and Standard Configurations imagination at work Specifications Flow Rates (Valve Only) Service @ 15 psi (1.03 ) drop....................... 76 (17.3 m 3 /hr) Backwash
More informationTECHNICAL SHEET AUTOTROL PERFORMA CV CONTROL VALVE - LOGIX SERIES WATER PURIFICATION VALVES - AUTOTROL
TECHNICAL SHEET AUTOTROL PERFORMA CV CONTROL VALVE - LOGIX SERIES TECHNICAL SHEET AUTOTROL PERFORMA CV CONTROL VALVE - LOGIX SERIES TIMER CHARACTERISTICS 742 TIME CLOCK Electronic time clock (chronometric)
More informationWater Specialist WS1TT Drawings and Service Manual
Water Specialist 2nd Tank Connection Port Treated Water Outlet Untreated Water Inlet In/Out Head 2nd Tank Connection Port Control Valve Proper installation shown above. See page 2 for issues that arise
More informationWater Specialist 1.5" CC Control Valve Programming and Drawings Manual
Water Specialist 1.5" CC Control Valve Programming and Drawings Manual Page 2 WS 1.5 CC Man u al WS 1.5 CC Man u al Page 3 OEM General Instructions The control valve offers multiple procedures that allow
More informationWater Specialist WS2H and WS3 Control Valve Manual
Water Specialist WS2H and WS3 Control Valve Manual HYDROCARBONS SUCH AS KEROSENE, BENZENE, GASOLINE, ETC., MAY DAMAGE PRODUCTS THAT CONTAIN O-RINGS OR PLASTIC COMPONENTS. EXPOSURE TO SUCH HYDROCARBONS
More informationIron Blaster System Owner s Manual
Iron Blaster System Owner s Manual CANADIAN ADDRESS 92 Commerce Park Dr. Unit #2 Barrie, ON L4N 8W8 Canada www.waterdepot.com IMPORTANT: Do not make any adjustments to these units, they are factory set.
More informationSuperior Water And Air
Superior Water And Air 80-974-9090 800-974-7638 OWNERS MANUAL Model 32-CL990 & 48-CL990 General Information Congratulations on having purchased a quality and well built Superior Water Softener. On a normal
More informationWater Specialist WS1TT Drawings and Service Manual
Water Specialist HYDROCARBONS SUCH AS KEROSENE, BENZENE, GASOLINE, ETC., MAY DAMAGE PRODUCTS THAT CONTAIN O-RINGS OR PLASTIC COMPONENTS. EXPOSURE TO SUCH HYDROCARBONS MAY CAUSE THE PRODUCTS TO LEAK. DO
More information7-LX B 7-LX B 7-LX B 7-LX B 7-LX B
ESTATE SERIES INSTALLATION, OPERATING AND SERVICE MANUAL ELECTRONIC WATER SOFTENER WITH THE ¼ X-FACTOR CONTROL VALVE PROGRAMMED FOR PRE-FILL BRINING OPTION 7-LX5-00B 7-LX5-50B 7-LX5-00B 7-LX5-300B 7-LX5-00B
More informationConsumer s Filter Manual. ProMate 6.0 Iron Curtain Junior Filter Manual
ProMate 6.0 Iron Curtain Junior Filter Manual Consumer s Filter Manual Manufactured by: HELLENBRAND, INC. 404 Moravian Valley Road Waunakee, Wisconsin 53597 Web: www.hellenbrand.com Email: info@hellenbrand.com
More informationTTV Series. Softening Water System. Installation, Operation and Maintenance Manual. Revised 01/17/13
TTV Series Softening Water System Installation, Operation and Maintenance Manual CAUTION: Read and Follow all safety rules and operating instructions before first use of product. DEALER NAME: DEALER PHONE
More informationCOMMERCIAL CONTROL VALVES. Magnum Control Valve
COMMERCIAL CONTROL VALVES Magnum Control Valve COMMERCIAL CONTROL VALVES Magnum Control Valve Controller Options The Pentair Water Magnum Control Valve is one of the most versatile valves on the market.
More informationWater Specialist igen Control Valve Programming and Cover Drawing Manual
Water Specialist igen Control Valve Programming and Cover Drawing Manual Page 2 igen Man u al igen Man u al Page 3 Table of Contents igen Front Cover and Drive Assembly...4 WS1 igen Drive Cap Assembly,
More informationOWNER S MANUAL FOR ALL GREENSAND SYSTEMS
OWNER S MANUAL FOR ALL GREENSAND SYSTEMS THIS MANUAL IS TO BE LEFT WITH THE OWNER OF THE EQUIPMENT FOR REFERENCE AND PURPOSES AND TECHNICAL GUIDANCE. IT IS STRONGLY RECOMMENDED THAT QUALIFIED DEALER SERVICE
More informationControl Valves - Fleck, Autotrol, Clack, AquaMatic & Others
Control Valves - Fleck, Autotrol, Clack, AquaMatic & Others Product Index Page Fleck 2510 & 1500 Control Valves... 9-3 Fleck 4650 Hot Water Control Valve... 9-3 Fleck 5600, 6700 & ProFlo Control Valves...
More informationTABLE OF CONTENTS JOB SPECIFICATIONS
IRONSOFT INSTALLATION, OPERATING AND SERVICE MANUAL ELECTRONIC IRONSOFT WATER SOFTENER WITH THE X-FACTOR CONTROL VALVE PROGRAMMED FOR PRE-FILL BRINING OPTION 7-FESLX-B 7-FESLX-B 7-FESLX-5B 7-FESLX-60B
More informationSIMPLEX PREMIUM WATER SOFTENER INSTALLATION AND USER GUIDE
SIMPLEX PREMIUM WATER SOFTENER INSTALLATION AND USER GUIDE 1 TABLE OF CONTENTS 1) Installation... 2 1.1) Pre-installation instructions... 2 1.2) General Installation and Service Warnings... 2 1.3) Site
More informationWater Specialist EI Control Valve Programming and Cover Drawing Manual
Water Specialist EI Control Valve Programming and Cover Drawing Manual Page 2 EI Man u al EI Man u al Page 3 Table of Contents EI Front Cover and Drive Assembly... 4 Regeneration and Error Screens... 5
More informationInstallation Instructions & Owner s Manual LINDYSPRING LCR Series II Water Conditioners
Installation Instructions & Owner s Manual LINDYSPRING LCR Series II Water Conditioners 115 N.W. Van Buren Topeka, KS 66603 Phone: 785-234-5551 Toll-free: 800-880-2022 Toll-free Fax: 800-269-3478 TABLE
More informationWater Specialist CK and EQ Control Valve Programming and Cover Drawing Manual
Water Specialist CK and EQ Control Valve Programming and Cover Drawing Manual Page 2 CK and EQ Manual CK and EQ Manual Page 3 Table of Contents CK Front Cover and Drive Assembly...4 OEM General Programming
More informationPRESSURE GAGES AND TEST TAPS
CAT 500.1 FRF series filters. Polyglass 100 psi vessels with top mount Task Master II 1 ½ valve and single point PVC internals. FMF series filters. Carbon steel epoxy lined and coated vessels with side
More informationFLECK 2850S SERVICE MANUAL. waterpurification.pentair.com
FLECK 2850S SERVICE MANUAL waterpurification.pentair.com TABLE OF CONTENTS JOB SPECIFICATION SHEET...2 INSTALLATION...3 START-UP INSTRUCTIONS...3 3200 TIMER SETTING PROCEDURE...4 3210 TIMER SETTING PROCEDURE...4
More informationWater Specialist PR Control Valve Programming and Cover Drawing Manual
Water Specialist PR Control Valve Programming and Cover Drawing Manual Page 2 PR Man u al PR Manual Page 3 Table of Contents PR Front Cover and Drive Assembly...4 OEM General Programming Instructions...5
More informationWater Specialist CI Control Valve Programming and Cover Drawing Manual
Water Specialist CI Control Valve Programming and Cover Drawing Manual Page 2 CI Man u al CI Man u al Page 3 Table of Contents CI Front Cover and Drive Assembly...4 OEM General Instructions...5 OEM Cycle
More informationPre-Treatment Control Valve (Fleck 2850s) & Timer (Fleck SXT)
Operation Manual Pre-Treatment Control Valve (Fleck 2850s) & Timer (Fleck SXT) 1020 Industrial Drive, Orlinda, TN 37141 615-654-4441 sales@specialtyh2o.com 615-654-4449 fax TABLE OF CONTENTS Section 1
More informationINSTALLATION, OPERATING AND SERVICE MANUAL ELECTRONIC WATER SOFTENER TIME CLOCK MODEL FEATURING THE 2002S VALVE
INSTALLATION, OPERATING AND SERVICE MANUAL ELECTRONIC WATER SOFTENER TIME CLOCK MODEL FEATURING THE 00S VALVE 7-LECT-4 7-FESLECT-4 7-LET-4 7-FESLET-4 7-LET-3 7-FESLET-3 7-LET-45 7-FESLET-45 7-LET-60 7-FESLET-60
More informationFLECK 2900S SERVICE MANUAL. waterpurification.pentair.com
FLECK 2900S SERVICE MANUAL waterpurification.pentair.com TABLE OF CONTENTS JOB SPECIFICATION SHEET 2 INSTALLATION 3 START-UP INSTRUCTIONS 3 3200 TIMER SETTING PROCEDURE 4 3210 & 3220 TIMER SETTING PROCEDURE
More informationTotalCare Series. Water Conditioners
TotalCare Series Water Conditioners TABLE OF CONTENTS Preinstallation Instructions for Dealers............................3 Bypass Valve................................................3-4 Installation..................................................5-6
More informationWater Specialist 1 Control Valve Series Model: WS Control Valve Series Model: WS1.25
Water Specialist 1 Control Valve Series Model: WS1 1.25 Control Valve Series Model: WS1.25 Operation and Instruction Manual for OEM Only. Please Note: This operation and instruction manual is for the training
More informationFLECK 2850 CONTROL VALVE
FLECK 2850 CONTROL VALVE SERVICE MANUAL waterpurification.pentair.com TABLE OF CONTENTS JOB SPECIFICATION SHEET...2 INSTALLATION...3 START-UP INSTRUCTIONS...3 3200 TIMER SETTING PROCEDURE...4 3210 TIMER
More informationOZONE ZENTEC CAPSULATE FILTER INSTALLATION AND USER GUIDE
OZONE ZENTEC CAPSULATE FILTER INSTALLATION AND USER GUIDE 1 TABLE OF CONTENTS 1) Installation... 2 1.1) Pre-installation instructions... 2 1.2) General Installation and Service Warnings... 2 1.3) Site
More informationTNT SERIES WATER CONDITIONERS
TNT SERIES WATER CONDITIONERS For Commercial & Industrial Applications Apartment Buildings Boiler Water Treatment Car Washes Commercial Buildings Condominiums Factories Hospitals Laundries Mobile Home
More informationWS1TC Series Installation and Operation Manual
WS1TC Series Installation and Operation Manual Table of Contents Installation... 3 Bypass Valve... 4 Start-up Instructions... 6 General Information... 7 User Displays/Settings... 8 Installer Displays/Settings...
More informationNUGEN Pure Water Systems Fusion XT. Installation Instructions and Owners Manual
NUGEN Pure Water Systems Installation Instructions and Owners Manual XT-48, XT-60, XT-70, XT-70ER, and XT-90 XT-32C Page 2 Page 3 Table of Contents Your Water Test...3 Pre-Installation Instructions...4
More information7-LXC-50B 7-LXC-75B 7-LXC-100B 7-LX-75B 7-LX-100B 7-LX-150B 7-LX-200B 7-LX-300B
INSTALLATION, OPERATING AND SERVICE MANUAL DIAMOND LINE LX ELECTRONIC WATER SOFTENER WITH THE XFACTOR CONTROL VALVE PROGRAMMED FOR PREFILL BRINING OPTION 7LXC50B 7LXC75B 7LXC00B 7LX75B 7LX00B 7LX50B 7LX00B
More informationSTORM. ProMate-6.0 Iron Curtain Storm Series
STORM ProMate-6.0 Iron Curtain Storm Series Consumer s Filter Manual p/n 111701 Rev. C Updated 10/02/18 2018 Manufactured by: HELLENBRAND, INC. 404 Moravian Valley Road Waunakee, Wisconsin 53597 www.hellenbrand.com
More informationWatco Pro Series Water Conditioner
Watco Pro Series Water Conditioner Operation & Maintenance Manual Marketed Exclusively By: Lee Supply Corp. 6610 Guion Road Indianapolis, IN 46268 800-873-1103 Page 2 Quick Reference Chart GENERAL OPERATION
More informationControl Valves - Fleck, Autotrol, Clack, Aquamatic & Others
- Fleck, Autotrol, Clack, Aquamatic & Others Product Index Page Fleck 2510 183 Fleck 4650 Hot Water Control Valve 183 Fleck 5600, 6700 & ProFlo 184 Fleck 5800, 5800 XTR2 185 Fleck Valve Covers, 185 By-Pass
More informationFLECK 2750 DOWNFLOW SERVICE MANUAL. waterpurification.pentair.com
FLECK 2750 DOWNFLOW SERVICE MANUAL waterpurification.pentair.com TABLE OF CONTENTS JOB SPECIFICATION SHEET...2 INSTALLATION...3 START-UP INSTRUCTIONS...3 3200 TIMER SETTING PROCEDURE...4 3210 TIMER SETTING
More informationWater Specialist 1 Control Valve Series Model: WS Control Valve Series Model: WS1.25
Water Specialist 1 Control Valve Series Model: WS1 1.25 Control Valve Series Model: WS1.25 Operation and Instruction Manual for OEM Only. Please Note: This operation and instruction manual is for the training
More informationFleck 2510 & 2510 Econominder
Fleck 2510 & 2510 Econominder Service Manual TABLE OF CONTENTS JOB SPECIFICATION SHEET...1 INSTALLATION...2 START-UP INSTRUCTIONS...2 3200 TIMER SETTING PROCEDURE...3 3210 TIMER SETTING PROCEDURE...4 3200,
More informationADVANCE. Backwashing Filters and Tannin Filter. Installation Instructions & Owner s Manual
ADVANCE Backwashing Filters and Tannin Filter Installation Instructions & Owner s Manual Ta b l e o f Co n t e n t s : Preinstallation Instructions Page 1 Bypass Valve Page 1-2 Installation Page 3-4 Sulfur
More informationModel WS1 Demand. Operation & Maintenance Manual. 114 Vista Parkway Avon, IN New Aqua L.L.C.
Model WS1 Demand Operation & Maintenance Manual 114 Vista Parkway Avon, IN 46123 317-272-6721 2008 New Aqua L.L.C. Page 2 Quick Reference Chart GENERAL OPERATION When the system is operating one of two
More informationINDUSTRIAL GRADE WATER SOFTENERS LWTS INDUSTRIAL SERIES
INDUSTRIAL GRADE WATER SOFTENERS LWTS INDUSTRIAL SERIES 150,000 TO 900,000 GRAIN CAPACITY (Single, Twin Alternating, Triple or Quadruple Demand Systems) 1 P age Industrial Performance and Proven Reliability
More informationCAT231.1 PRESSURE GAUGE AND TEST TAP KIT SKID MOUNTING 220V, 50HZ, 1Ø OPERATING CONDITIONS 25 TO 100 PSI 100 F MAX IMUM TEMPERATURE SERIES METER
CAT231.1 STANDARD FEATURES TASK MASTER III - 1 ½ / 2 - FIVE CYCLE 316 STAINLESS STEEL VALVE - SIDE MOUNT SUPER FLOW KIT S ON 2, 3 & 4 SYSTEMS (SERVICE FLOW BYPASS DIAPHRAGM VALVES) ERCt ELECTRONIC TIMER
More informationFLECK 2750 DOWNFLOW SERVICE MANUAL.
FLECK 2750 DOWNFLOW SERVICE MANUAL www.pentairaqua.com TABLE OF CONTENTS JOB SPECIFICATION SHEET...2 INSTALLATION...3 START-UP INSTRUCTIONS...3 3200 TIMER SETTING PROCEDURE...4 3210 TIMER SETTING PROCEDURE...4
More informationInstallation and Service Manual Backwash Filter Systems
Installation and Service Manual Backwash Filter Systems Ceramic Filters Co. Inc. 11617 Highway 124 Brooklyn, Michigan 49230 USA Technical Support: 800-427-7986 Email: eramic@frontiernet.net Page 1 Table
More informationOwner s Filter Manual. ProMate 6.0 Iron Curtain Junior Filter Manual
ProMate 6.0 Iron Curtain Junior Filter Manual Owner s Filter Manual Manufactured by: Hellenbrand, Inc. 404 Moravian Valley Road Waunakee, Wisconsin 53597 Phone: 608 849-3050 Fax: 608-849-7398 Web: www.hellenbrand.com
More informationOwner s Manual HELLENBRAND, INC.
Owner s Manual Manufactured by: HELLENBRAND, INC. 404 Moravian Valley Road Waunakee, Wisconsin 53597-2509 Phone: 608-849-3050 Fax 608-849-7398 Web: www.hellenbrand.com Email: info@hellenbrand.com 800160
More informationAQT-56SE ELECTRONIC SERIES PROGRAMMING MANUAL CONTROL VALVES
AQT-56SE ELECTRONIC SERIES PROGRAMMING MANUAL TABLE OF CONTENTS General Residential Installation 3 AQT-56SE Keypad 4 Control Operation 5 Master Programming - Setting the Time of Day 6 - Setting the Regeneration
More informationSmartChoice. Gen II itwin. Water Conditioning System. Installation, Operation, and Maintenance Manual. Installation, Operation, and Maintenance Manual
SmartChoice TM Gen II itwin Water Conditioning System > > CLOCK REGEN NEXT Installation, Operation, and Installation, Operation, and 7785 East US Hwy 36 Avon, IN 46123 (317) 272-3000 (800) 447-5582 For
More informationINSTALLATION, OPERATING AND SERVICE MANUAL ELECTRONIC WATER FILTER TIME CLOCK MODEL FEATURING THE 2002F VALVE
INSTALLATION, OPERATING AND SERVICE MANUAL ELECTRONIC WATER FILTER TIME CLOCK MODEL FEATURING THE 00F VALVE COLOR, TASTE, ODOR SEDIMENT/TURBIDITY 7-LETCT- 7-LETCT- 7-LETCT- IRON FILTER 7-LETIM- 7-LETIM-
More informationCAT231.1 SHUT OFF KIT (SOK) TO PREVENT BYPASS PRESSURE GAUGE AND TEST TAP KIT SKID MOUNTING 220V, 50HZ, 1Ø
CAT231.1 STANDARD TASK MASTER III - 1 ½ VALVE 316 SS - SIDE MOUNT SERVICE FLOW BYPASS DIAPHRAGM VALVES. ERCt ELECTRONIC TIMER 100 PSI EPOXY LINED AND COATED CARBON STEEL MINERAL TANKS ACCUMATIC BRINE SYSTEM.
More informationAQT-275 SERIES SERVICE MANUAL CONTROL VALVES
AQT-275 SERIES CONTROL VALVES SERVICE MANUAL Table of Contents General Residential Installation 3 Valve Start-up Procedures 4 Regeneration Cycle Program Setting Procedures 5 Water Conditional Diagrams
More informationINDUSTRIAL GRADE WATER SOFTENERS LWTSF INDUSTRIAL SERIES
INDUSTRIAL GRADE WATER SOFTENERS LWTSF INDUSTRIAL SERIES 150,000 TO 1,100,000 GRAINS CAPACITY (Single, Twin, Triple or Quadruple Demand Systems Available) 1 P age Industrial Performance and Proven Reliability
More informationModel Downlow & Uplow
Model 2750 - Downlow & Uplow Service Manual IMPORTANT: Fill in Pertinent Information on Page 3 for Future Reference Table of Contents Job Speciication Sheet... 3 General Commercial Pre-Installation Check
More informationAQT-56 POWERFLO SERIES SERVICE MANUAL CONTROL VALVES
AQT-56 POWERFLO SERIES SERVICE MANUAL Table of Contents Products Checking List 3 General Residential Installation Check List 4 AQT-56ST Softener Timer Control Valve Start-up Procedures 5 AQT-56FT Filter
More informationAQUAMATIC CONTROL VALVES, STAGERS AND CONTROLLERS
AQUAMATIC CONTROL VALVES, STAGERS AND CONTROLLERS BUILDING SOLUTIONS AND PARTNERSHIPS AQ Matic is a leader in high technology flow control products and provides innovative solutions for commercial and
More informationWATER SOFTENER WITH MICROPROCESSOR INSTALLATION & OPERATING INSTRUCTIONS
WATER SOFTENER WITH MICROPROCESSOR INSTALLATION & OPERATING INSTRUCTIONS Model : Serial No : AS1041MP-CL.. Manufacturer and Supplier of FILTRATION & WATER TREATMENT PRODUCTS for commercial, industrial
More informationModel 2750 Downflow. Service Manual. IMPORTANT: Fill in Pertinent Information on Page 3 for Future Reference
Model 2750 Downflow Service Manual IMPORTANT: Fill in Pertinent Information on Page 3 for Future Reference Table of Contents Job Specification Sheet... 3 Installation Instructions... 4 Start-Up Instructions...
More informationSanitizer Plus Series
Sanitizer Plus Series Water Conditioners For Models: ASP-0 ASP-05 ASP-5 ASP-0 ASP-05 ASP-5 TABLE OF CONTENTS Pre-Installation Instructions for Dealers... Bypass Valve.... Installation.... 5 Programming
More informationProFloSE. Downflow Brining Service Manual. IMPORTANT: Fill in pertinent information on page 2 for future reference.
ProFloSE Downflow Brining Service Manual IMPORTANT: Fill in pertinent information on page 2 for future reference. Job Specification Sheet Job Number Model Number Water Test Capacity Of Unit Max. Per Regeneration
More informationOwners Manual Installation Instructions. For Models PTCF PTCF PTCF
Owners Manual Installation Instructions For Models PTCF-5600-09 PTCF-5600-10 PTCF-5600-13 Table of Contents Page 2 Subject Page PURE TECH 2000 Diagram 4 Job Specification Sheet 5 System Overview 6 Pre
More informationSanitizer Plus Series. Water Conditioners
Sanitizer Plus Series Water Conditioners TABLE OF CONTENTS Preinstallation Instructions for Dealers............................3 Bypass Valve................................................3-4 Installation..................................................5-6
More informationManual for Operation & Maintenance Of Metered Carbon Filter
Industry Leader in RO Expertise and Membrane Applications since 1983 Manual for Operation & Maintenance Of Metered Carbon Filter for Models: W-G744EM W-G844EM W-G940EM W-G1054EM W-G1252EM W-G1354EM W-G1465EM
More informationIron Gate Air Pump System Manual
Iron Gate Air Pump System Manual Installation and Operating Instructions Iron Gate Iron Filter System Manufactured by: R.E Prescott Co., Inc. 10 Railroad Avenue Exeter, New Hampshire 03833 Phone: (603)
More informationImpression Plus Series
Impression Plus Series Metered Water Softeners For Certified Models: IMP-844 IMP-948 IMP-044 IMP-054 IMP-248 IMP-354 Certified Cabinet Models: IMPC-835 IMPC-935 IMPC-035 TABLE OF CONTENTS Pre-Installation
More informationFLECK 2510 SERVICE MANUAL. waterpurification.pentair.com
FLECK 2510 SERVICE MANUAL waterpurification.pentair.com TABLE OF CONTENTS JOB SPECIFICATION SHEET...2 INSTALLATION...3 START-UP INSTRUCTIONS...3 3200 TIMER SETTING PROCEDURE...4 3210 TIMER SETTING PROCEDURE...4
More informationProblem and Solutions Manual
Problem and Solutions Manual By Caden Bird Table of Contents Table of Contents... iii Introduction... 5 Identifying the Problem... 7 Taking Apart the Valve... 13 Various Problems and Solutions... 23 Putting
More informationInstallation / Operation Manual
Installation / Operation Manual Installation Requirements Pressure Range: 10-150 psi Temperature Range: 40-120 F Max Service Flow Rate: 25gpm NOTE: Position filter on a level surface. Filter must be installed
More informationGeneral Operation. To set Time of Day. To set Time of Regeneration / Backwash
1 General Operation When the system is operating one of two displays will be shown: time of day or days until the next regeneration. Pressing UP or DOWN will toggle between the two choices. To set Time
More informationImpression Plus Series
Impression Plus Series Metered Water Softeners For Certified Models: IMP-8 IMP-98 IMP-0 IMP-05 IMP-8 IMP-5 Certified Cabinet Models: IMPC-85 IMPC-95 IMPC-05 TABLE OF CONTENTS Pre-Installation Instructions
More informationMur-lok. Mur-lok Polypropylene Quick-Connect Fittings & Valves. Check Valves. Fixed NPTF 90 Elbows. Check Valve Elbow. Swivel NPTF 90 Elbows
Polypropylene Quick-Connect Fittings & Valves Polypropylene Quick-Connect Fittings & Valves G.A. Murdock offers the largest selection of polypropylene quick-connect fittings and valves on the market. These
More informationMGTE Series 1 1/2 Metered & Time Clock
INSTALLATION, OPERATION, AND MAINTENANCE MANUAL MGTE Series 1 1/2 Metered & Time Clock COMMERCIAL WATER CONDITIONERS COMPLETE FOR FUTURE REFERENCE: MODEL NO: SERIAL NO: DATE INSTALLED: DEALER: Marlo Incorporated
More informationUF Series. Membrane Filtration System. Model CCUF-844
UF Series Membrane Filtration System Model CCUF-8 TABLE OF CONTENTS Pre-installation Instructions for Dealers...3 Bypass Valve.... Installation....5 Programming Procedures... Start-up Instructions...3
More informationUF Series. Membrane Filtration System. Model CCUF-844
UF Series Membrane Filtration System Model CCUF-844 TABLE OF CONTENTS Pre-installation Instructions for Dealers...3 Flushing Schedule...3 Bypass Valve....4 Installation.... 5-7 Programming Procedures...
More informationSTORM. ProMate-6.0 Iron Curtain Storm Series
STORM ProMate-6.0 Iron Curtain Storm Series Owner s Filter Manual Manufactured by: HELLENBRAND, INC. 404 Moravian Valley Road Waunakee, Wisconsin 53597 Web: www.hellenbrand.com Email: info@hellenbrand.com
More informationCareSoft. Series. Metered Water Softeners. For Models: UCS-844 UCS-948 UCS-1044 UCS-1054 UCS-1248 UCS-1354
CareSoft Series Metered Water Softeners For Models: UCS-8 UCS-98 UCS-0 UCS-05 UCS-8 UCS-5 TABLE OF CONTENTS Pre-Installation Instructions for Dealers... Bypass Valve.... Installation.... 5-7 Programming
More information