Wires & Cables. Next is Ready TM. Marine Cables

Size: px
Start display at page:

Download "Wires & Cables. Next is Ready TM. Marine Cables"

Transcription

1 Next is Ready TM Marine Cables

2 Index S.. Description 1.. Siechem Profile Siechem Manufacturing, Laboratories & Testing Facilities 3. Siechem an early bird in Marine Cable segment in India 4. FAQ : Why Siechem EBXL XLPO Cables for Marine Application? 5. MGCH APC, EMC Screened 0.6/1 kv Control Cable 6. MGH APC, 0.6/1 kv Control Cable 7. MGSGO APC, EMC Screened 0.6/1 kv Control Cable 8. MPRX APC, 0.6/1 kv Control Cable 9. MPRXCX APC, EMC Screened 0.6/1 kv Control Cable 10. FMGCH APC, Pair, EMC Screened 50V Control Cable 11. FMGSGO APC, Paired, EMC Screened 50V Control Cable 1. FMSGSGO APC, Paired, EMC Screened 0.6/1 kv Control Cable 13. LMGSGO APC, Paired, EMC Screened 500V Control Cable 14. LFMGSSGO ATC, Paired, EMC Screened 50V Control Cable 15. LFMSGSSGO ATC, 3 Pair, EMC Screened 50V Control Cable 16. WIRING CABLE - SY Stranded type, APC, Galvanised Steel wire braided Control Cable 17. WIRING CABLE - SY APC, Tinned Steel wire braided, 50V Control Cable 18. XLFMKK APC, Paired, EMC Screened 50V Control Cable 19. LKM-HF APC, 0.6/1 kv Control Cable 0. LKM-FRHF APC, 0.6/1 kv Control Cable 1. LKAM-HF APC, 0.6/1 kv Al Screened Control Cable. LKEM-HF APC, 0.6/1 kv Control Cable 3. LKSM-HF APC, 0.6/1 kv Control Cable 4. LKSM-HF (I) APC, 150/50 (300V) Control Cable 5. LKSM-FRHF APC, 0.6/1 kv Control Cable 6. RFE-HF APC, Paired, 150/50(300V) Control Cable 7. RFE-HF (I) APC, Paired, EMC Screened, 150/50(300V) Control Cable 8. RFA-HF APC, Paired, EMC Screened, 150/50(300V) Control Cable 9. RFA-HF (I) APC, Paired, EMC Screened, 150/50(300V) Control Cable 30. RFE-FRHF APC, Paired, 150/50(300V) Control Cable 31. RFE-FRHF (I) APC, Paired, 150/50(300V) Control Cable 3. RFA-FRHF APC, Paired, 150/50(300V) Control Cable 33. RFA-FRHF (I) APC, Paired, EMC Screened, 150/50(300V) Control Cable 34. PBS Field Bus Cable 35. MGCG APC, Paired, 600V/1 kv Control Cable Page

3 Index S FMGCG APC, Paired, 150/50 V Control Cable 37. MYY-J APC Control Cable 38. MYY-O APC Control Cable 39. SY APC, Tinned Steel Screening Control Cable 40. SY-Stranded Type APC, Galvanised Steel wire braided Screening Control Cable 41. LFMKK APC, Paired, EMC Screening Control Cable 4. LMKK APC, EMC Screening Control Cable 43. LMGSG APC, EMC Screening Control Cable 44. EED EED Table C1 : Single Core Cable 46. EED Table C : Twin and Three Core Cables 47. EED Table C3 : Multicore Cables 48. EED Table C4 : Twin and Multicore Cables 49. EED Table C5 : Multipaired Cables Collectively Screened 50. EED Table C6 : Multicore Cables Individually Screened Cores 51. EED Table C7 : Multipaired, Cables, Pairs, Individually Screened 5. EED Table C8 : Multicore Cables, Collectively Screened 53. EED Table C9 : Miniature Multicore Cables, Unscreened (Or) Individually (Or) Collectively Screened 54. EED Table C10 : Miniature Pair and Triple Cables, Collectively, Screened 55. EED Table C11 : Miniature Multicore Cables, Individually and Collectively Screened Cores 56. EED Table C1 : Twin and Three Core Cables, overall Screened 57. EED Table C13 : Multicore Cables, Overall Screened 58. EED 50-1 Description 59. EED 50-1 Table 1 : Multipair Cables - Collectively Screened - 0.mm 60. EED 50-1 Table : Individually Screened Plus Unscreened Quad Cables, Collectively Screened - 0. mm 61. EED 50-1 Table 3 : Multipair Individually Screened Plus Unscreened Multipair Cables, Collectively Screened - 0.6mm, 600V 6. EED 50-1 Table 4 : Multipair Individually Screened Plus Unscreened Multipair Cables - 0.6mm, 600V 63. EED 50-1 Table 5 : Multiquad Individually Screened Cables, Collectively - 0.mm, 600V 64. EED 50-1 Table 6 : 5 Core Cable, 1 Pair Individually Screened - 0.6mm, 600V 65. EED 50-1 Table 7 : Multicore Cable, Collectively Screened mm, 600V 66. EED 50-1 Table 8 : Multicore Cable, Collectively Screened - 0.6mm, 600V 67. EED 50-1 Table 9 : Multicore Cable, Collectively Screened - 1.mm, 600V 68. EED 50-1 Table 10 : Multicore Cable, Double Collectively Screened - 0.6mm, 600V 69. EED 50-1 Table 11 : Multicore Cable, Double Individual Screens and Collectively Screened - 0.6mm, 600V 70. EED 50-1 Table 1 : Multipair Cables, Individual Screens and Collective Super Screen mm, 600V Page

4 Index S EED 50-1 Table 13 : Multicore Cables - Unscreened - 0.mm, 600V 7. EED 50-1 Table 14 : Multicore Cables - Unscreened mm, 600V 73. EED 50-1 Table 15 : Multicore Cables - Unscreened - 0.5mm, 600V 74. EED 50-1 Table 16 : Multicore Cables - Unscreened mm, 600V 75. EED 50-1 Table 17 : Multicore Cables - Unscreened mm, 600V 76. EED 50-1 Table 18 : Multicore Cables - Unscreened - 1.5mm and.5mm, 600V 77. EED 50-1 Table 19 : Multicore Cables - Extra thin wall insulated, Collectively Screened mm, 600V 78. EED 50-1 Table 0 : Multicore Cables - Unscreened - 1.5mm and.5mm, 600V 79. EED 50-1 Table 1 : Multipair Cables - Collectively Screened mm, 600V 80. EED 50-1 Table : Multipair Cables - Collectively Screened mm, 600V 81. EED 50-1 Table 3 : Multipair Cables - Individually Screened mm, 600V 8. EED 50-1 Table 4 : Multipair Cables - Individually Screened mm, 600V 83. EED 50-1 Table 5 : Single Core Cables (Unscreened) - 600V 84. EED 50-1 Table 6 : Two Core Cables (Unscreened) - 600V 85. EED 50-1 Table 7 : Three Core Cables (Unscreened) - 600V 86. EED 50-1 Table 8 : Multicore Cables - Unscreened, 600V 87. EED 50-1 Table 9 : Single and Multicore Cables - Collectively Screened, 600V 88. EED 50-1 Table 30 : Single and Multipair Cables - Collectively Screened, 600V 89. EED 50-1 Table 31 : Multipair Cables, Individually Screened, 600V 90. EED 50-1 Table 3 : Single and Multitriad, Collectively Screened, 600V 91. EED 50-1 Table 33 : Single and Multitriad, Individually Screened, 600V 9. EED 50-1 Table 34 : Singlecore Cables with Screen Oversheath, 600V 93. EED 50-1 Table 35 : Multicore with Screen Oversheath, 600V 94. EED 50-1 Table 36 : Singlecore Cables, Low Capacitance, 600V 95. EED 50-1 Table 37 : Multicore Cables Cores individually Screened, 600V 96. EED 50-1 Table 38 : Multicore Cables Cores Individually / Collectively Screened, 600V 97. EED 50-1 Table 39 : Singlecore Cables (Unscreened, Shore Supply), 1800V 98. EED 50-1 Table 40 : Overall Screened Cables 99. NES Table C1 : Multicore Cables - Unscreened 0. mm 101. Table C : Multicore Cables - Unscreened 0.35 mm 10. Table C3 : Multicore Cables - Unscreened 0.6 mm 103. Table C4 : Multicore Cables - Unscreened 1.0 mm 104. Table C5 : Multicore Cables - Unscreened 1.5 mm 105. Table C6 : Multicore Cables - Unscreened.5 mm Description Page

5 Index S Table C7 : Multicore Cables - Collectively Screened 0.35 mm 107. Table C8 : Multicore Cables - Collectively Screened 1.0 mm 108. Table C9 : Multipair Cables - Collectively Screened 0.35 mm 109. Table C10 : Multipair Cables - Collectively Screened 1.0 mm 110. Table C11 : Multipair Cables - Individually Screened 0.35 mm 111. Table C1 : Multipair Cables - Individually Screened 1.0 mm 11. Table C13 : Multipair Cables - Individually and Collectively Screened 0.35 mm 113. Table C14 : Multitriple Cables - Collectively Screened 0.35 mm 114. NES Table C1 : Singlecore Cables 116. Table C : Singlecore Flexible Cables 117. Table C3 : Singlecore Cables - Low Capacitance 118. Table C4 : Single and Multicore Cables, Copper Wire Braided Overall 119. Table C5 : 3 Core Flexible Cables (Large) 10. Table C6 : Multicore Cables 11. Table C7 : Multicore Cables (For DG) 1. Table C8 : Multicore Specially Flexing Cables 13. Table C9 : Multicore Specially Flexing Cables, Collectively Screened 14. Table C10 : Multicore Cables, Cores Individually Screened 15. Table C11 : Multicore Cables, Cores Individually Screened 16. Table C1 : Multipair Cables, Steel Wire Braided 17. Table C13 : Multitriple Cables Triples Individually Screened: Multicore Cables 18. Table C14 : Multitriple Cables Triples Collectively Screened 19. NES Table C1 : Singlecore Cables 131. Table C : Twin and Three Core Cables 13. Table C3 : Multicore Cables 133. Table C4 : Twin and Multicore Cables 134. Table C5 : Multipaired Cables Collectively Screened 135. Table C6 : Multicore Cables Individually Screened cores 136. Table C7 : Multipaired Cables Pairs Individually Screened cores 137. Table C8 : Multicore Cables Collectively Screened Description 138. Table C9 : Miniature Multicore Cables Unscreened or Individually or Collectively Screened 139. Table C10 : Miniature Pair and Triple Cables Collectively Screened 140. Table C11 : Miniature Multicore Cables Individually and Collectively Screened cores Page

6 Index S.. Description 141. Multicore Armoured and Sheathed Type P Control Cable 600V or 0.6/1kV 14. Electron Beam Cross-Linking, Product realiability, Test Methods & advantages 143. Comparative Study of EBXL HFFR(XLPO), Power Cables Vs Others 144. Marine Cable : Design Calculation for Maximum allowed Voltage drop 145. Maximum A.C. Continuous Current - Offshore & Marine applications 146. Current Rating and De Rating Factors 146. Life Time Expectation Page

7 Siechem - Profile Siechem a market leader in India for speciality wires and cables, established in 00 is having its head office at Chennai and factory at Pondicherry, India, equipped with fully automated manufacturing plant spread over 100,000 sq feet built-up area in an environment friendly surrounding. The Company employs about 300 people and has in-house R&D, Design, Manufacturing and Compounding facilities and hence cost effective and reliable in terms of its performance. The Company is zero debt and growing rapidly year on year with its innovative products. Siechem's In-house cable design studio can design and develop any type of cable with its experts supported by R&D team to make insulating, sheathing and jacketing compounds that any competitor can offer. Siechem has nearly a million part numbers for the various segments /market as mentioned below. For more information about Siechem, please visit. S Range of Products Automotive Cables Aerospace Cables Appliance Wires & Cables Building Wires Battery Cables Composite/Hybrid Cables Control & Switchboard Cables Contract Manufacturing of Wires & Cables Elastomeric & Special Thermoplastic & Thermoset Electron Beam Cross Linked Wires & Cables Fluoro Elastomer Insulated Cables Flexible Cables Fire Resistant Cables, Heat, Oil & Flame Resistant Cables Heat Shrinkable Products Jelly filled Telecom Cables Instrumentation Cables Mining Cables Nuclear Cables Offshore and Marine Shipboard Cables Oil and Gas - Petrochemical Cables Power Cables Power Cords Railway Quad & Signaling Cables Rolling stock Cables for Electric Locos, Metro Rail & Diesel Loco Cables Solar Cables Telecommunication Cables UL/ ETA/ CSA Standards Cables Welding Cables Wind Energy Cables Wiring Harness 6

8 SIECHEM EXTERNAL & INTERNAL FACTORY VIEW Manufacturing Facilities Laboratory and Testing Facilities 7

9 Siechem an early bird in Marine Cable segment in India Early entry in to Marine Cable segment has helped Siechem to develop the varities of Marine cables, that would definitely benefit customers to ü Get cost effective solutions ü Ready solution for any complex design ü Easy installation ü Reliability in delivery & producer performance A brief about Siechem Marine Cable Products : Siechem Marine, Control, instrumentation and Power cables for the harsh environments of Marine energy applications hot and cold of climate extremes, moisture, oil, and for saline conditions. In-house R & D and compounding facility of XLPO/Elastomeric insulation and specially formulated Jacket which is Electron Beam Cross Linked provide years of reliable service, withstanding the extreme environments without failing or degrading. Marine applications demand higher level of reliability with enhanced Thermal, Electrical, Mechanical and Weathering properties of Marine Cables. When downtime is unacceptable in marine applications where environment is also severely challenging, Siechem Marine cables offer reliable performance from -65 C to C as continuous operating temperature. Siechem also offers single stop solution for entire cabling with wide range of PV application such as ü ü Single Core EBXL Marine Cables Multi Core EBXL Marine Cables, ü Control, Instrumentation & Data Transmission Cables, Siechem Marine Cable products are environment friendly, meets RoHS norms as per European Standards. Designed for easy handling, quick. assembling at site, rugged, reliable and comparable with the best in the world and also meets many International standards. 8

10 FAQ : Why Siechem EBXL XLPO Cables for Marine Application? 1. Advantage of XLPO over PVC & XLPE ; Generally XLPO material is recommended for Marine cables because of enhanced operating temperature and hostile 0 weathering conditions. XLPO EBXL cable is rated for 10 C and Silicon 155 C continuous operating temperature, whereas XLPE cable is rated for 90 C only.. Choice of Tin coated copper or Tinned annealed copper: Annealing is compulsory to get lower resistivity and better flexibility. Tinned copper is what specified in specification for EBXL Marine cables. 3. Short circuit temperature : PVC : 150 C, XLPE : 50 C and and XLPO/Silicon : 80 C 4. Bending radius of cables: rmally it is 3 to 4 times the cable OD in flexible cables for EBXL XLPO/Silicon as against 9 times of XLPE / PVC. 5. material: PVC & XLPE insulations are common in Power Cables, whereas EBXL XLPO/Silicon material is used in Marine and Special application cables to keep the Electrical and Mechanical properties of the cables in elevated environmental temperature. 6. & Sheath color : is normally Red & Black and Sheath is Black. However, inner layer i.e. insulation color can be as per customer order Ampacity of cables. It is about 30% more than 90 C rated XLPE and about 43% more than PVC. Please also refer point no.19. In case of Silicon cores, it is even more. 8. Rated Voltage: 600/1000V AC or as per Customer order. 9. In class conductors for Cables of fixed installations, minimum no. of strands are specified whereas in flexible conductors maximum wire diameter of individual wire is specified, which falls in Class 5 Category. Both class and 5 are permitted to be used, but that depends on how critical it is in certain areas while installing the cables, especially in cold climate areas. 10. Cable preferred for fixed use: Armoured power, control and communication cables. 11. Weight of cable preferred: Please refer our leaflets for Cable Dimensions and Weight. 1. Stranded or Solid conductor - which is preferred? : Solid copper conductors are specified upto 6 Sq.mm and stranded conductor is used for sizes greater than 6 Sq.mm. change in conductor fabrication for Marine or other cables. 13. Flexibility: More in flexible conductors, class 5 & class 6, and it is less in stranded class conductors for fixed installations and least in Solid class 1 conductors for fixed installations. Flexibility is customer specific. 14. : Special cables for commercial places, locomotives, marine applications, aircraft wiring, Marine Cables etc. It has no Toxic emissions. 15. Submersible in water or not: XLPO/Silicone Marine cables are generally weather resistant and very good for water resistant applications. Hence, XLPO/ Silicon Marine Cables ideally meet Marine Cable needs at hostile conditions. 16. Electron beam cross linked procedure or CV curing process preferred?: Electron Beam Cross Linked is the superior way of curing the material which gives uniform enhanced Electrical, Thermal and Mechanical properties across the cable built. bye products are produced which are harmful to the insulation layer unlike in Chemical curing. EBXL is environment friendly and very reliable. 17. Various tests: a) conductor resistance, (b) voltage test on complete wire, (c) insulation continuity test, (d) Surface resistance sheath test, (e) resistance test: All test are carried out as per the relevant specifications. These are basic tests. But if you refer IEC, you will find very interesting tests are specified for 5 years life under severe working conditions. Siechem has 100% in house testing facility which can be witnessed by customer. 18. Recommended ambient temperature to be considered for Marine application: As specified in International Specifically, PVC cables can withstand 70 C, XLPE for 90 C and XLPO 10 C and Silicon for 155 C. As the Cable is the main nerve system in marine installations, if proper cable is not installed, voltage drop, efficiency and system failure cannot be prevented. 9

11 0 19. De-rating factor: As per IEC specification. Also as per IEC16, if the cable is over loaded, for 8 C increase over the rated temperature, the cable life is 0 reduced to 50%. If the temperature rise is more than 8 C, proportionately insulation resistance of cable weakens and thus the premature failure of cable occurs. Compound PVC XLPE (EBXL) XLPO (EBXL) Temperature Rating 0 70 C 0 90 C 0 10 C At 40 C ambient, if the load is 80% of the rated cable size for e.g.10sq.mm copper cable, the temperature of the conductor and current will be 56 0 C 44A 7 0 C 67A 96 0 C 350A At 55 C ambient, if the load is 80% of the rated cable size the temperature of the conductor will be 0 71 C 0 87 C C Current 80% of the cable capacity 100% 97% 9% Same size conductor i.e.10sq.mm if it is 100% loaded over the cable capacity (43% more in case of EBXL XLPO Vs PVC or PVC FRLS cables) 305A 336A 437A 0. n standard cable size: Siechem is specialized in making any cable size as per customer requirement from 0.5 to 1000 Sq mm EBXL XLPO Marine cable life: 5 years minimum or 0,000 hours continuously at rated temperature, i.e. -65 to + 10 C. operating conditions Hence, reliable under severe and hostile. Cost : Marginally high due to E-beam cross linking and better insulation and sheathing material used for 5 years guaranteed life. Since copper dominates nearly 90% 0 of weight in case of higher size cables, the gap between ordinary 90 C XLPE cables and XLPO 10 C rated will be very little. But, performance is 30% more than conventional cables. Therefore, EBXL XLPO is more economical in a long run. 3. Where EBXL XLPO is used: In USA, Europe and in India. Most of the Marine customers go in for this technology. 4. Reference standards : IEC , American Bureau of Shipping, Lloyds Register, Defence etc. Siechem makes cables as per the specification. 5. Design & cable size: This is the key area. It is up to the Engineering Team who smartly design the cable route and sizes. Siechem can supply any cable size that meets that particular conditions. 10

12 MGCH Fixed installations in marine vehicles Minimizes radio interferences and electrical influences For open deck applications in passenger ships Flame retardant : IEC (Cat A) Tests & Materials : IEC / : IEC / 1- Shielding Effectiveness : DIN EN Electron Beam Cross Linked Smoke Density : IEC / 1- (DIN EN 5068/1-) Oil resistant Inner Sheath Separator Foil Screen Separator Foil Siechem MGCH : Electrolytic, stranded, annealed copper wire. IEC 608 Class (Class 5 / tinned on request) : HEPR Compound () : compound : Glass Mica Tape : Electrolytic Copper Braided Screen (90% coverage) MGCH (EMC) type is wrapped by a Copper tape in addition to this screen for100% coverage : Glass Mica Tape :, flame retardant, thermoset, polyolefin based jacket compound (Black or Grey) : - 40 C to +10 C : 0.6/1kV Test Voltage : 3.5 kv Bending Radius(Min) : 8 x Cable Diameter Short-circuit temp. (max.) ISO OHSAS : 80 C XX* XX XX XX XX XX XX XX XX XX XX XX XX XX XX XX 1 x x.5 1 x 4 1 x 6 1 x 10 1 x 16 1 x 5 1 x 35 1 x 50 1 x 70 1 x 95 1 x 10 1 x x x 40 1 x x 1.5 x.5 x 4 x 6 x 10 x 16 x x x.5 3 x 4 3 x 6 3 x 10 3 x 16 3 x 5 3 x

13 x x x x x x x x x x x x x x x x x x x x x x x te : XX * : Please add last two digits in the part number as per the colour code given hereunder replacing XX while ordering. Red - 01 Yellow - 0 Blue - 03 Black - 04 Green - 05 Yellow-Green - 06 Grey - 07 Brown - 08 White - 09 Orange - 10 Violet - 11 Chocolate - 1 Tan - 13 Charcoal - 14 LT Blue - 15 DK Grey - 16 LT Green - 17 DK Green - 18 DK Blue - 19 Purple - 0 Pink

14 MGH Fixed installations in marine vehicles Installation beneath the first metal deck level Inner Sheath : Electrolytic, stranded, annealed copper wire. IEC 608 Class (Class 5 / tinned on request) : HEPR () : compound :, flame retardant, thermoset, polyolefin based jacket compound (Black or Grey) : - 40 C to +10 C : 0.6/1kV Resistance : 1400 MOhms x km Test Voltage : 3.5 kv Bending Radius(Min) : 6 x Cable Diameter Short-circuit temp. (max.) 0 : 80 C ISO OHSAS Flame retardant : IEC (Cat A) Tests & Materials : IEC / : IEC / 1- Electron Beam Cross Linked Smoke Density : IEC / 1- (DIN EN 5068/1-) Oil resistant Siechem MGH XX* XX XX 30 3 XX 30 7 XX 30 8 XX XX 30 3 XX XX XX XX XX 30 4 XX XX XX XX 1 x x.5 1 x 4 1 x 6 1 x 10 1 x 16 1 x 5 1 x 35 1 x 50 1 x 70 1 x 95 1 x 10 1 x x x 40 1 x x 1.5 x.5 x 4 x 6 x 10 x 16 x x x.5 3 x 4 3 x 6 3 x 10 3 x 16 3 x 5 3 x

15 x x x x x x x x x x x x x x x x x x x x x x x te : XX * : Please add last two digits in the part number as per the colour code given hereunder replacing XX while ordering. Red - 01 Yellow - 0 Blue - 03 Black - 04 Green - 05 Yellow-Green - 06 Grey - 07 Brown - 08 White - 09 Orange - 10 Violet - 11 Chocolate - 1 Tan - 13 Charcoal - 14 LT Blue - 15 DK Grey - 16 LT Green - 17 DK Green - 18 DK Blue - 19 Purple - 0 Pink

16 MGSGO Permanent installations in marine crafts Installations in open decks as Control and Power cables Flame retardant : IEC (Cat A) Tests & Materials : IEC / : IEC / 1- Electron Beam Cross Linked Smoke Density : IEC / 1- (DIN EN ) Oil resistant Foil Screen Screen Separator Siechem MGSGO : Electrolytic, stranded, annealed copper wire. IEC 608 Class (Class 5 / tinned on request) : HEPR () : Al-Mylar Tape : Electrolytic Copper Braided Screen : Polyester Tape :, flame retardant, thermoset, polyolefin based jacket compound (Black) : - 40 C to +10 C : 0.6/1kV Bending Radius(Min) : 5 x Cable Diameter Short-circuit temp. (max.) ISO OHSAS : 80 C XX* XX XX XX XX XX XX XX XX XX XX XX XX XX 1 x 4 1 x 6 1 x 10 1 x 16 1 x 5 1 x 35 1 x 50 1 x 70 1 x 95 1 x 10 1 x x x 40 1 x x 1.5 x.5 x 4 x 6 x 10 x 16 x x x.5 3 x 4 3 x 6 3 x 10 3 x 16 3 x 5 3 x 35 3 x 50 3 x

17 x x x x x x x x x x x te : XX * : Please add last two digits in the part number as per the colour code given hereunder replacing XX while ordering. Red - 01 Yellow - 0 Blue - 03 Black - 04 Green - 05 Yellow-Green - 06 Grey - 07 Brown - 08 White - 09 Orange - 10 Violet - 11 Chocolate - 1 Tan - 13 Charcoal - 14 LT Blue - 15 DK Grey - 16 LT Green - 17 DK Green - 18 DK Blue - 19 Purple - 0 Pink

18 MPRX Fixed installations on ships and offshore units in all locations below the upper metallic deck Installations in radio stations For open deck applications in passenger ships Inner Sheath Separator Foil : Electrolytic, stranded, annealed copper wire. IEC 608 Class (Class 5 / tinned on request) : Electron Beam Cross Linked Polyethylene : Electron Beam Cross Linked Polyolefin : Glass Mica Tape :, flame retardant, thermoset, polyolefin based jacket compound (Black) Max. Operating Voltage Test Voltage Bending Radius(Min) Max. Temp. in Service Short-circuit temp (max) : - 40 C to +10 C : 0.6/1kV : 1. kv : 3.5 kv : 4 x Cable Diameter 0 : 90 C 0 : 80 C ISO OHSAS Flame retardant : IEC (Cat A) Tests & Materials : IEC /353 : IEC Electron Beam Cross Linked Smoke Density : IEC Gases corrosivity : IEC Gases toxicity : toxicity to IEC Oil resistant Siechem MPRX XX* XX XX XX XX XX XX XX XX XX XX XX XX XX 1 x 4 1 x 6 1 x 10 1 x 16 1 x 5 1 x 35 1 x 50 1 x 70 1 x 95 1 x 10 1 x x x 40 1 x x 1.5 x.5 x 4 x 6 x 10 x 16 x x x.5 3 x 4 3 x 6 3 x 10 3 x 16 3 x 5 3 x 35 3 x 50 3 x

19 x 95 3 x x x.5 4 x 4 4 x 6 4 x 10 4 x 16 4 x 5 4 x 35 4 x 50 4 x 70 4 x x x.5 7 x x x x x x x te : XX * : Please add last two digits in the part number as per the colour code given hereunder replacing XX while ordering. Red - 01 Yellow - 0 Blue - 03 Black - 04 Green - 05 Yellow-Green - 06 Grey - 07 Brown - 08 White - 09 Orange - 10 Violet - 11 Chocolate - 1 Tan - 13 Charcoal - 14 LT Blue - 15 DK Grey - 16 LT Green - 17 DK Green - 18 DK Blue - 19 Purple - 0 Pink

20 MPRXCX Fixed installations on ships and offshore units in all locations below the upper metallic deck Minimizes radio interferences and electrical influences Installation on passenger ships Separator Foil Screen : Electrolytic, stranded, annealed copper wire. IEC 608 Class (Class 5 / tinned on request) : Electron Beam Cross Linked Polyethylene : Glass Mica Tape : Electrolytic Copper Braided Screen :, flame retardant, thermoset, plastic polyolefin based jacket compound (Black) : - 40 C to +10 C : 0.6/1kV Bending Radius(Min) : 4 x Cable Diameter Short-circuit temp (max.) ISO OHSAS : 80 C Flame retardant : IEC (Cat A) Tests & Materials : IEC /353 : IEC Electron Beam Cross Linked Smoke Density : IEC Gases corrosivity : IEC Gases toxicity : toxicity to IEC Oil resistant Siechem MPRXCX XX* XX XX XX XX XX XX XX XX XX XX XX XX XX 1 x 4 1 x 6 1 x 10 1 x 16 1 x 5 1 x 35 1 x 50 1 x 70 1 x 95 1 x 10 1 x x x 40 1 x x 1.5 x.5 x 4 x 6 x 10 x 16 x x x.5 3 x 4 3 x 6 3 x 10 3 x 16 3 x 5 3 x 35 3 x 50 3 x

21 x x x x x x x x x x x x x x x x x x x x x x te : XX * : Please add last two digits in the part number as per the colour code given hereunder replacing XX while ordering. Red - 01 Yellow - 0 Blue - 03 Black - 04 Green - 05 Yellow-Green - 06 Grey - 07 Brown - 08 White - 09 Orange - 10 Violet - 11 Chocolate - 1 Tan - 13 Charcoal - 14 LT Blue - 15 DK Grey - 16 LT Green - 17 DK Green - 18 DK Blue - 19 Purple - 0 Pink

22 FMGCH Used as Control and Communication cables in radio, radar & information systems of marine vehicles Minimizes radio interferences and electrical influences For use in above and below decks Flame retardant : IEC (Cat A) Tests & Materials : IEC /375 : IEC / 1- Electron Beam Cross Linked Smoke Density : IEC 61034/1- Gases corrosivity : IEC Gases toxicity : toxicity to IEC Oil resistant : Electrolytic, stranded, annealed copper wire. IEC 608 Class (Class 5 / tinned on request) : HEPR () Layup : Cores laid up in pairs, pairs laid up concentrically Separator : Glass Mica Tape Screen : Electrolytic copper braided screen(90% coverage) Separator : Glass Mica Tape :, flame retardant, thermoset, polyolefin based jacket compound (Green) Siechem FMGCH : - 40 C to +10 C : 50 V Test Voltage : 1.5 kv Bending Radius(Min) : 8 x Cable Diameter Max. Temp. in Service Short-circuit temp (max) ISO : 85 C OHSAS : 80 C x x 0.75 x x x x x x x x x x x x x x

23 FMGSGO Fixed installations on marine craft Minimizes radio interferences and electrical influences Fire resistant insulation Flame retardant : IEC (Cat A) n corrosive and low toxic gas emission Electron Beam Cross Linked Oil resistant Screen Separator Foil : Electrolytic, stranded, annealed copper wire. IEC 608 Class (Class 5 / tinned on request) : Electron Beam Cross Linked Polyolefin : Electrolytic Copper Braided Screen : Polyester Tape : Electron Beam Cross Linked Polyolefin (Black) : - 40 C to +10 C : 50 V Resistance : 1400 MOhms x km Bending Radius(Min) : 5 x Cable Diameter Max. capacity at 800 Hz : 50nF/km Max. Temp. in Service Short-circuit temp (max.) ISO OHSAS : : 85 C 0 : 80 C Siechem FMGSGO x x x x x x x x x x x x x x

24 FMSGSGO Fixed installations on marine vehicles Fixed installations in power & control systems below and above decks Flame retardant : IEC (Cat A) : IEC / 1- Electron Beam Cross Linked Oil Resistant : Electrolytic, stranded, annealed copper wire. IEC 608 Class (Class 5 / tinned on request) : EPR Cores laid up in pairs Separator Foil : Glass Mica Tape Screen : Electrolytic Copper Braided Screen Separator Foil : Glass Mica Tape Screen : Electrolytic Copper Braid Screen Separator Foil : Polyester Tape :, flame retardant, thermoset, polyolefin based jacket compound (Black) : - 40 C to +10 C : 0.6/1 kv Bending Radius(Min) : 5 x Cable Diameter Short-circuit temp. (max.) ISO OHSAS : 80 C Siechem FMSGSGO x x x x x x x x x x x x x x

25 LMGSGO Fixed installations on marine vehicles Fixed installations in power & control systems below and above decks : Electrolytic, stranded, annealed copper wire. IEC 608 Class (Class 5 / tinned on request) : EPR Inner Sheath : compound Screen : Electrolytic Copper Braid Screen Separator Foil : Polyester Tape :, flame retardant, thermoset, polyolefin based jacket compound (Black) : - 40 C to +10 C : 500 V Bending Radius(Min) : 5 x Cable Diameter DC permissible current rating : 15 A Max. Temp. in Service Short-circuit temp. (max.) 0 : 85 C 0 : 80 C Flame retardant : IEC (Cat A) : IEC / 1- Electron Beam Cross Linked Oil resistant ISO OHSAS Siechem LMGSGO x x x x x x x x x x x x x 1.5 x.5 3 x.5 4 x.5 6 x.5 7 x

26 LFMGSSGO Fixed installations on marine vehicles Fixed installations in power & control systems below and above decks : Electrolytic, stranded, annealed tinned copper wire. IEC 608 Class : Electron Beam Cross Linked Polyolefin Inner Sheath : compound Screen : Electrolytic Tinned Double Copper Braid Separator Foil : Polyester Tape : Elastomer based compound (Black) : - 40 C to +10 C : 50 V Bending Radius(Min) : 6 x Cable Diameter Max. capacity at 800 Hz : 10nF/km Max. Temp. in Service Short-circuit temp. (max.) 0 : 85 C 0 : 80 C Flame retardant : IEC (Cat A) : IEC / 1- Electron Beam Cross Linked Oil resistant ISO OHSAS Siechem LFMGSSGO x x x x x x x x x x x x

27 LFMSGSSGO Fixed installations on marine vehicles Fixed installations in power & control systems below and above decks Flame retardant : IEC (Cat A) : IEC / 1- Electron Beam Cross Linked Oil resistant : Electrolytic, stranded, annealed tinned copper wire. IEC 608 Class : Electron Beam Cross Linked Polyolefin Paired Screen : Electrolytic Tinned Copper Braided Screen Separator : Polyester Tape Inner Sheath : Polyester Tape overall inner covering Screen : Electrolytic Tinned Copper Braid Screen Separator : Polyester Tape Overall Screen: Tinned Copper Braid Separator : Polyester Tape : Elastomer based compound (Black) : - 40 C to +10 C : 50 V Bending Radius(Min) : 6 x Cable Diameter Max. Temp. in Service Short-circuit temp. (max.) ISO : 85 C 0 : 80 C OHSAS Siechem LFMSGSSGO x 3 x x 3 x

28 WIRING CABLE - SY STRANDED TYPE Fixed installations on ships Used in Production lines, conveyor systems, automatic assembly lines etc Protection against both mechanical and electronic interference to the cable function Inner Sheath Overall Screen : Electrolytic, stranded, annealed copper wire. IEC 608 Class 5 (Tinned on request) : PVC : PVC : Galvanized Steel wire braid : According to DIN VDE 007 (Black) Test Voltage Bending Radius(Min) Flexing Short-circuit temp. (max.) : - 40 C to +70 C : 50 V : 1500 V : 7.5 x Cable Diameter : +5 C to +70 C 0 : 160 C ISO OHSAS Flame resistant : IEC Extensively oil resistant : DIN VDE 050 Chemical resistant Self extinguish Siechem WIRING CABLE - SY STRANDED TYPE x x x x x x.5 4 x.5 5 x.5 4 x 4 5 x 4 4 x 6 5 x

29 WIRING CABLE - SY Fixed installations on ships and offshore units in all locations below the upper metallic deck Minimizes radio interferences and electrical influences Installation on passenger ships Screen : Electrolytic, stranded, annealed copper wire. IEC 608 Class 5 (Tinned on request) : PVC : Tinned Steel wire braid : PVC (Black) Test Voltage Bending Radius(Min) Flexing Short-circuit temp. (max.) : - 40 C to +70 C : 50 V : 1500 V : 7.5 x Cable Diameter : +5 C to +70 C 0 : 160 C ISO OHSAS Flame resistant : IEC Oil resistant : DIN VDE 050 Chemical resistant Self extinguish Siechem WIRING CABLE - SY XX* XX XX XX XX XX XX XX 1 x 6 1 x 10 1 x 16 1 x 5 1 x 35 1 x 50 1 x 70 1 x te : XX * : Please add last two digits in the part number as per the colour code given hereunder replacing XX while ordering. Red - 01 Yellow - 0 Blue - 03 Black - 04 Green - 05 Yellow-Green - 06 Grey - 07 Brown - 08 White - 09 Orange - 10 Violet - 11 Chocolate - 1 Tan - 13 Charcoal - 14 LT Blue - 15 DK Grey - 16 LT Green - 17 DK Green - 18 DK Blue - 19 Purple - 0 Pink

30 XLFMKK Fixed installations on marine craft Minimizes radio interferences and electrical influences For open deck applications in passenger ships Flame retardant : IEC (Cat A) Test and Material : VG 8878 : Electrolytic, stranded, annealed copper wire. IEC 608 Class 5 (Tinned on request) : PVC with polyamid coating Cores laidup in pair, pairs laid up concentrically Separator : Glass Mica Tape Pair-Screening : Electrolytic Copper Braided Screen Separator : Al-Mylar Tape Inner Sheath : PVC Separator : Water blocking tape Screen : Electrolytic Copper Braided Screen (85% coverage) : Flame retardant, PVC based compound (Green) Test Voltage Bending Radius(Min) Short-circuit temp. (max.) ISO OHSAS : - 40 C to +85 C : 50 V : 1.5 kv : 5 x Cable Diameter 0 : 160 C Siechem XLFMKK x x x x x x

31 LKM-HF Fixed installations on ships Flame retardant : IEC : IEC series Smoke emission : IEC series Bedding : Electrolytic, stranded, annealed copper wire. IEC 608 Class (Class 5 on request) : Cross Linked Polyethylene : Separator tape : Cross Linked Polyolefin, Standard colour Grey or Black, Other colours on request Test Voltage ISO OHSAS : - 40 C to +10 C : 0.6/1k V (1.kV) : 3.5 kv Siechem LKM-HF Marine Cable XX* 1C x XX 1C x XX 1C x XX 1C x XX 1C x XX 1C x XX 1C x XX 1C x XX 1C x XX 1C x XX 1C x XX 1C x XX 1C x C x 1.5 C x.5 C x 4.0 C x 6 C x C x 1.5 3C x.5 3C x 4 3C x 6 3C x 10 3C x 16 3C x 5 3C x 35 3C x 50 3C x 70 3C x 95 3C x 10 3C x

32 C x 1.5 4C x.5 4C x C x C x C x C x C x C x C x C x C x C x C x C x C x C x C x C x C x C x C x C x C x C x C x C x C x C x C x C x 1.5 4C x C x C x te : XX * : Please add last two digits in the part number as per the colour code given hereunder replacing XX while ordering. Red - 01 Yellow - 0 Blue - 03 Black - 04 Green - 05 Yellow-Green - 06 Grey - 07 Brown - 08 White - 09 Orange - 10 Violet - 11 Chocolate - 1 Tan - 13 Charcoal - 14 LT Blue - 15 DK Grey - 16 LT Green - 17 DK Green - 18 DK Blue - 19 Purple - 0 Pink

33 LKM-FRHF Fixed installations on ships Bedding : Electrolytic, stranded, annealed copper wire. IEC 608 Class : Mica tape & Cross Linked Polyethylene : Separator tape : Cross Linked Polyolefin, Standard colour Orange, Other colours on request Test Voltage ISO : - 40 C to +10 C : 0.6/1k V (1.kV) : 3.5 kv OHSAS Flame retardant : IEC Fire resistant : IEC series : IEC series Smoke emission : IEC series Siechem LKM-FRHF Fire Resistant Marine Cable C x 1.5 C x.5 C x C x 1.5 3C x.5 3C x 4 3C x 6 3C x 10 3C x 16 3C x 5 3C x 35 3C x 50 3C x 70 3C x C x 1.5 4C x.5 4C x 4 4C x 6 4C x 10 4C x 16 4C x 5 4C x 35 4C x C x 1.5 5C x C x 1.5 7C x C x 1.5 1C x

34 C x C x C x C x

35 LKAM-HF Fixed installations on ships Flame retardant : IEC : IEC series Smoke emission : IEC series Screen : Electrolytic, stranded, annealed copper wire. IEC 608 Class : Cross Linked Polyethylene : Drain wire of tinned copper 1.5mm (in all sizes) Aluminium polyester tape, coverage 100% : Cross Linked Polyolefin Standard colour Grey or Black, Other colours on request Test Voltage ISO : - 40 C to +10 C : 0.6/1k V (1.kV) : 3.5 kv OHSAS Siechem LKAM-HF Marine cable C x 1.5 C x C x 1.5 3C x C x 1.5 4C x C x 1.5 5C x C x 1.5 7C x C x C x C x 1.5 1C x C x C x C x 1.5 7C x

36 LKEM-HF Fixed installations in Ships, Switchboards, Control panels and other enclosures : Electrolytic, stranded, annealed copper wire. IEC 608 Class 5 : Cross Linked Polyethylene Test Voltage : - 40 C to +10 C : 0.6/1k V (1.kV) : 3.5 kv ISO OHSAS Flame retardant : IEC : IEC series Smoke emission : IEC series Siechem LKEM-HF Marine Cable XX * 1C x XX 1C x XX 1C x XX 1C x XX 1C x XX 1C x XX 1C x XX 1C x XX 1C x XX 1C x XX 1C x XX 1C x XX 1C x XX 1C x te : XX * : Please add last two digits in the part number as per the colour code given hereunder replacing XX while ordering. Red - 01 Yellow - 0 Blue - 03 Black - 04 Green - 05 Yellow-Green - 06 Grey - 07 Brown - 08 White - 09 Orange - 10 Violet - 11 Chocolate - 1 Tan - 13 Charcoal - 14 LT Blue - 15 DK Grey - 16 LT Green - 17 DK Green - 18 DK Blue - 19 Purple - 0 Pink

37 LKSM-HF Fixed installations on ships (EMC) Minimizes radio interferences and electrical influences Flame retardant : IEC : IEC series Smoke emission : IEC series Bedding Armour : Electrolytic, stranded, annealed copper conductor. IEC 608 Class (Class 5 on request) : Cross Linked Polyethylene : Filler tape : Drain wire (in 1.5mm and.5mm size cables) copper wire braid, coverage > 90% : Cross Linked Polyolefin Standard colour Grey or Black, Other colours on request. Test Voltage ISO OHSAS : - 40 C to +10 C : 0.6/1k V (1.kV) : 3.5 kv Siechem LKSM-HF Marine Cable XX* 1C x XX 1C x XX 1C x XX 1C x XX 1C x XX 1C x XX 1C x XX 1C x XX 1C x XX 1C x XX 1C x XX 1C x XX 1C x C x 1.5 C x.5 C x 4.0 C x 6 C x C x 1.5 3C x.5 3C x 4 3C x 6 3C x 10 3C x 16 3C x 5 3C x 35 3C x 50 3C x 70 3C x 95 3C x 10 3C x

38 C x C x C x C x C x C x C x C x C x C x C x C x C x C x C x C x C x C x C x C x C x C x C x C x C x C x C x C x C x C x C x C x C x C x te : XX * : Please add last two digits in the part number as per the colour code given hereunder replacing XX while ordering. Red - 01 Yellow - 0 Blue - 03 Black - 04 Green - 05 Yellow-Green - 06 Grey - 07 Brown - 08 White - 09 Orange - 10 Violet - 11 Chocolate - 1 Tan - 13 Charcoal - 14 LT Blue - 15 DK Grey - 16 LT Green - 17 DK Green - 18 DK Blue - 19 Purple - 0 Pink

39 LKSM-HF (I) Fixed installations on ships (EMC) Minimizes radio interferences and electrical influences Flame retardant : IEC : IEC series Smoke emission : IEC series : Electrolytic, stranded, annealed copper wire. IEC 608 Class : Cross Linked Polyethylene Bedding : Separator tape Armour : Drain wire, copper wire braid, coverage >90% : Cross Linked Polyolefin, standard colour Grey or Black, Other colours on request ISO : - 40 C to +10 C :150/50V (300V) OHSAS Siechem LKSM-HF (I) Marine Cable C x C x C x C x C x C x C x C x C x C x C x C x C x C x

40 LKSM-FRHF Fixed installations on ships (EMC) Minimizes radio interferences and electrical influences Flame retardant : IEC Fire resistant : IEC series : IEC series Smoke emission : IEC series Bedding Armour : Electrolytic, stranded, annealed copper wire. IEC 608 Class : Mica tape, Cross Linked Polyethylene : Separator tape : Drain wire copper wire braid, coverage > 90% : Cross Linked Polyolefin, Standard colour Orange, Other colours on request Test Voltage ISO : - 40 C to +10 C : 0.6/1kV (1.V) : 3.5 kv OHSAS Siechem LKSM-FRHF Marine Cable C x 1.5 C x.5 C x C x 1.5 3C x.5 3C x 4 3C x 6 3C x 10 3C x 16 3C x 5 3C x 35 3C x 50 3C x 70 3C x 95 3C x C x 1.5 4C x.5 4C x 4 4C x 6 4C x 10 4C x 16 4C x 5 4C x 35 4C x C x 1.5 5C x C x 1.5 7C x

41 C x 1.5 1C x C x C x C x C x C x

42 RFE-HF Fixed installations on ships (EMC) Minimizes radio interferences and electrical influences Flame retardant : IEC : IEC series Smoke emission : IEC series Bedding Armour : Electrolytic, stranded, annealed copper wire. IEC 608 Class : Cross Linked Polyethylene : Filler tape : Drain wire (in all sizes) copper wire braid, coverage >94% : Cross Linked Polyolefin, Standard colour Grey Other colours on request ISO : - 40 C to +10 C : 150/50 V (300V) OHSAS Siechem RFE-HF Marine Cable x x x 4 x x x x x x x x x x x x x x x x x x x x x x x x 4 x x x x x x x x x x x x x x x x x x x x x x 4 x 1.5 x x x x x x x x x x x x

43 x x x x x x /33 4

44 RFE-HF (I) Fixed installations on ships (EMC) Minimizes radio interferences and electrical influences Flame retardant : IEC : IEC series Smoke emission : IEC series Pair Screen Bedding Armour : Electrolytic, stranded, annealed copper wire. IEC 608 Class : Cross Linked Polyethylene : Plastic coated aluminium tape and a tinned copper drain wire : Filler tape : Drain wire (in all sizes) copper wire braid, coverage >90% : Cross Linked Polyolefin, Standard colour Grey, Other colours on request ISO : - 40 C to +10 C : 150/50 V (300V) OHSAS Siechem RFE-HF(I) Marine Cable x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x

45 RFA-HF Fixed installations on ships (EMC) Minimizes radio interferences and electrical influences Flame retardant : IEC : IEC series Smoke emission : IEC series Separator Screen : Electrolytic, stranded, annealed copper conductor IEC 608 Class : Cross Linked Polyethylene : Separator tape : Drain wire tinned copper & aluminium polyester copper tape, coverage 100% : Cross Linked Polyolefin, Standard colour Grey, Other colours on request ISO : - 40 C to +10 C : 150/50V (300 V) OHSAS Siechem RFA-HF Marine Cable x x x 4 x x x x x x x x x x x x x x x x x x x x x x x x 4 x x x x x x x x x x x x x x x x x x x /36 44

46 RFA-HF (I) Fixed installations on ships (EMC) Minimizes radio interferences and electrical influences Flame retardant : IEC : IEC series Smoke emission : IEC series Pair Screen Bedding Armour : Electrolytic, stranded, annealed copper wire. IEC 608 Class : Cross Linked Polyethylene : Plastic coated aluminium tape and a tinned copper drain wire : Separator tape : Drain wire tinned copper Aluminium polyester tape, coverage 100% : Cross Linked Polyolefin, Standard colour Grey, Other colours on request ISO : - 40 C to +10 C : 150/50 V (300V) OHSAS Siechem RFA-HF (I) Marine Cable x x x x x x x x x x x x x x x x x x

47 RFE-FRHF Fixed installations on ships (EMC) Minimizes radio interferences and electrical influences Flame retardant : IEC Fire resistant : IEC : IEC series Smoke emission : IEC series Bedding Armour Sheath : Electrolytic, stranded, annealed copper wire. IEC 608 Class : Mica tape & Cross Linked Polyethylene : Filler tape : drain wire (in all sizes) & copper wire braid, coverage > 90% : Cross Linked Polyolefin, Standard colour Orange, Other colours on request ISO : - 40 C to +10 C : 150/50 V (300V) OHSAS Siechem RFE-FRHF Marine Cable x x x 4 x x x x x x x x x x x x x x x x x x x x x x 4 x x x x x x x x x x x x x x x x x /39 46

48 RFE-FRHF (I) Fixed installations on ships (EMC) Minimizes radio interferences and electrical influences Flame retardant : IEC Fire resistant : IEC : IEC series Smoke emission : IEC series : Electrolytic, stranded, annealed copper wire. IEC 608 Class : Mica tape & Cross Linked Polyethylene Pair Screen Bedding Armour Sheath : Plastic coated aluminium tape and a tinned copper drain wire : Filler tape : Drain wire copper & copper wire braid, coverage > 90% : Cross Linked Polyolefin, Standard colour Orange, Other colours on request ISO : - 40 C to +10 C : 150/50V (300V) OHSAS Siechem RFE-FRHF (I) Marine Cable x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x

49 RFA-FRHF Fixed installations on ships (EMC) Minimizes radio interferences and electrical influences Flame retardant : IEC Fire resistant : IEC : IEC series Smoke emission : IEC series Bedding Screen Sheath : Electrolytic, stranded, annealed copper wire. IEC 608 Class : Mica tape & Cross Linked Polyethylene : Separator tape : Drain wire tinned copper & aluminium polyester tape coverage 100% : Cross Linked Polyolefin, standard colour Orange, Other colours on request ISO : - 40 C to +10 C : 150/50V (300V) OHSAS Siechem RFA-FRHF Marine Cable x x x 4 x 0.75 x x x x x x x x x x x x x x x x x x /33 48

50 RFA-FRHF(I) Fixed installations on ships (EMC) Minimizes radio interferences and electrical influences Flame retardant : IEC Fire resistant : IEC : IEC series Smoke emission : IEC series : Electrolytic, stranded, annealed copper wire IEC 608 Class : Mica tape & Cross Linked Polyethylene Pair Screen : Plastic coated aluminium tape & a tinned copper drainwire Bedding : Separator tape Collective Screen : Drain wire tinned copper and Aluminium polyester tape coverage 100% : Cross Linked Polyolefin, Standard colour Orange, Other colours on request. ISO : - 40 C to +10 C : 150/50V (300V) OHSAS Siechem RFA-FRHF (I) Marine Cable x x x x x x x x x x x x x x x x x x

51 PBS Field Bus Cable Fixed installations on ships (EMC) Minimizes radio interferences and electrical influences Flame retardant : IEC : IEC series Smoke emission : IEC series Pair Twisting Bedding Screen Inner Sheath : Electrolytic, stranded, annealed copper wire. : Polyethylene / foamed polyethylene : Separator tape : Plastic coated aluminium tape & tinned copper braid, coverage 100% : Purple, Cross Linked Polyolefin : Grey, Cross Linked Polyolefin ISO : - 40 C to +10 C : 600 V OHSAS Siechem PBS Marine Cable C x x

52 MGCG Fixed installations on ships Offshore units in all places and open decks. : Electrolytic, stranded, annealed copper wire. : HEPR Bedding : Filler or Tape Armouring : Separator tape, Bare Copper braid : CR (Cross Linked Polychloroprene Rubber) Test Voltage ISO : - 40 C to +10 C : 600 V / 1kV : 3.5 kv OHSAS Flame retardant Excellent screening. Siechem MGCG Marine Cable XX XX XX XX XX XX XX XX XX XX XX XX XX XX C x 4 1C x 6 1C x 10 1C x 16 1C x 5 1C x 35 1C x 50 1C x 70 1C x 95 1C x 10 1C x 150 1C x 185 1C x 40 1C x 300 C x 1.5 C x.5 C x 4 C x 6 6.0/ / / / / / / / / /.5 1.5/ / / /3.5 10/1.5 11/ / / C x / C x / C x 5 0.5/ C x / C x / C x / C x / C x / C x / C x 5.0/ C x / C x / C x / C x / C x / C x /

53 C x.5 4C x 4.0 4C x 6.0 4C x 10 4C x 16 4C x 5 4C x 35 4C x 50 4C x 70 4C x 95 5C x 1.5 5C x.5 1.5/ / / / / / / / / / / / C x / C x / C x / C x / C x / C x / C x 1.5.5/ te : XX * : Please add last two digits in the part number as per the colour code given hereunder replacing XX while ordering. Red - 01 Yellow - 0 Blue - 03 Black - 04 Green - 05 Yellow-Green - 06 Grey - 07 Brown - 08 White - 09 Orange - 10 Violet - 11 Chocolate - 1 Tan - 13 Charcoal - 14 LT Blue - 15 DK Grey - 16 LT Green - 17 DK Green - 18 DK Blue - 19 Purple - 0 Pink

54 FMGCG Fixed installations in communication, radio, control and data processing facilities on ships. Flame retardant Smoke density Gases corrosivity Gases toxicity Electro magnetic interference resistance. : Electrolytic, stranded, annealed copper wire. : EPR ( Cross Linked Ethylene Propylene Rubber) Laying up : Pair stranding ( Pair Cable = Quad stranding) Armour : Separator tape Screen : Electrolytic Copper braid Separator : Separator tape : CR (Cross Linked Polychloroprene Rubber) Siechem FMGCG Marine Cable Test Voltage ISO : - 40 C to +10 C : 600 V / 1kV : 1500 V OHSAS P x 0.75 P x P x P x P x P x P x P x / /10 1/ / / /.5.0/ /

55 MYY - J Fixed installations in communication, radio, control and data processing facilities on ships. : Electrolytic, stranded, annealed copper wire. : PVC : PVC Test Voltage : - 40 C to +10 C : 600 V / 1kV : 1500 V ISO OHSAS Flame retardant Smoke density Gases corrosivity Gases toxicity Electro magnetic interference resistance. Siechem MYY-J Marine Cable G G G G G 3G1.5 4G1.5 5G1.5 3G.5 4G

56 MYY - O Fixed installations in communication, radio, control and data processing facilities on ships. : Electrolytic, stranded, annealed copper wire. : PVC : PVC Test Voltage : - 40 C to +10 C : 600 V / 1kV : 1500 V ISO OHSAS Flame retardant Smoke density Gases corrosivity Gases toxicity Electro magnetic interference resistance. Siechem MYY-O Marine Cable C x 1.5 3C x 1.5 4C x 1.5 5C x 1.5 3C x.5 4C x

57 SY Suited for use in Control units, production lines, communication systems, conveyor belts, ship building. Used for fixed or mobile installation in dry, damp or wet areas. : Fine wire stranded, plain copper conductor : PVC Screening : Tinned Steel-wire braided : PVC Test Voltage ISO : - 40 C to +10 C : 60 V : 1500 V OHSAS Flame retardant Smoke density Gases corrosivity Gases toxicity Electro magnetic interference resistance. Siechem SY Marine Cable XX 1C X XX 1C X XX 1C X XX 1C X XX 1C X XX XX XX 1C X 50 1 x 70 1 x

58 SY - Stranded Type Ideal for all Fixed installations. Suited for use in production lines, conveyor systems, ship building, automatic assembly lines, etc. Excellent protection against both mechanical and electronic interference. : Fine stranded, Plain copper conductor. : PVC Laying up : Core stranded in layers with optimal lay-length Inner Sheath : PVC Screening : Galvanized steel wire braided : PVC Test Voltage ISO : - 40 C to +70 C : 3000 V OHSAS Flame retardant Smoke density Gases corrosivity Gases toxicity Electro magnetic interference resistance. Siechem SY - Stranded Marine Cable C X 1.5 3C X 1.5 4C X 1.5 5C X 1.5 7C X C X.5 4C x.5 5C x C x 4 5C x C x 6 5C x

59 LFMKK Designed for radio and radar units. Used to install above and below the decks. : Stranded copper conductor. : PVC Polyamide Protective covering Four cores formed into a star-quad, two diagonally opposite cores make up a telecommunications pair, star-quads laid up concentrically. Inner Sheath : PVC Screening : Plain copper wire braided : Heat Resistant PVC ISO : - 40 C to +70 C OHSAS Flame retardant Siechem LFMKK Marine Cable x x x x x x x x x x x x

60 LMKK For fixed installation on marine craft above and below deck. : Stranded copper conductor. : PVC with Polyamide Protective coating Laying up : Core stranded in layers with optimal lay-length Inner Sheath : PVC Screening : Waterproofed plain copper braided : PVC ISO : - 40 C to +85 C OHSAS Flame retardant Siechem LMKK Marine Cable C X 1.5 3C X 1.5 4C X 1.5 5C X 1.5 7C X C X 1.5 1C X C X C X C X 1.5 4C X 1.5 7C X C X C X.5 3C X.5 4C X

61 LMGSG For fixed installation on marine craft above and below deck. : Stranded copper conductor. : Heat Resistant EPR Laying up : Core stranded in layers with optimal lay-length Separator Tape : Flame resistant Foil Screening : Plain copper braided Separator Tape : Polyester foil : Chloroprene ISO : - 40 C to +85 C OHSAS Flame retardant Siechem LMGSG Marine Cable C X C X C X C X C X C X C X C X C X C X C X C X C X C X C X C X C X

62 EED Single Core Cables Twin & Three Core Cables Multicore Cables Twin & Multicore Cables Multipaired Cables (Collectively Screened) Multicore Cables (Individually Screened Cores) Multipaired Cables (Pairs Individually Screened) Multicore Cables (Collectively Screened) Miniature Multicore Cables (Unscreened / Individually / Collectively Screened) Miniature Pair & Triple Cables (Collectively Screened) Miniature Multicore Cables (Individually / Collectively Screened) Twin & Three Core Cables (Overall Screened) Multicore Cables (Overall Screened) 61

63 EED TABLE C1 : SINGLE CORE CABLE Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Protective Tape : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with IS : : Electron Beam Cross Linked Silicone Rubber Compound : Glass Braid / Lacquer : Electron Beam Cross Linked Polyolefin Compound Test Voltage Bending Radius(Min) Flexing Fixed ISO OHSAS : - 30 C to +10 C : 440 V : -3.5 kv : 10 x Cable Diameter : 4 x Cable Diameter Fire retardant Siechem Single Core Marine Cable A C X C X 1.0 1C X 1.5 1C X.5 1C X 4 1C X 6 1C X 10 1C X 16 1C X 5 1C X 35 1C X 50 1C X 70 1C X 95 1C X 10 1C X 150 1C X 185 1C X 40 1C X 300 1C X 400 1C X 500 1C X EED C1 6

64 TABLE C : TWIN AND THREE CORE CABLES Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Fire retardant Protective Tape Binder Tape : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with IS : : Electron Beam Cross Linked Silicone Rubber Compound : Glass Braid / Lacquer : Glass Mica Tape : Electron Beam Cross Linked Polyolefin Compound Test Voltage Bending Radius(Min) Flexing Fixed ISO OHSAS : - 30 C to +10 C : 440 V : -3.5 kv : 10 x Cable Diameter : 4 x Cable Diameter Siechem Twin and Three Core Marine Cables A C x 0.75 C x 1 C x 1.5 C x.5 C x 4 C x 6 C x 10 C x 16 C x 5 C x 35 C x 50 C x 70 C x A C X C x 1 3C x 1.5 3C x.5 3C x 4 3C x 6 3C x 10 3C x 16 3C x 5 3C x 35 3C x 50 3C x 70 3C x 95 3C x 10 3C x 150 3C x 185 3C x EED C 63

65 TABLE C3 : MULTICORE CABLES Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Fire retardant Protective Tape Binder Tape : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with IS : : Electron Beam Cross Linked Silicone Rubber Compound : Glass Braid / Lacquer : Polyester Tape : Electron Beam Cross Linked Polyolefin Compound Test Voltage Bending Radius(Min) Flexing Fixed ISO OHSAS : - 30 C to +10 C : 440 V : -3.5 kv : 10 x Cable Diameter : 4 x Cable Diameter Siechem Multicore Marine Cables A A A A C X 10 7C X 16 7C X 5 7C X 35 7C X 50 7C X 70 14C X.5 14C X 4 14C X 6 14C X 10 14C X 16 14C X 5 14C X 35 18C X 4 18C X 6 18C X 10 18C X 16 30C X C X C X.5 30C X 4 30C X 6 30C X EED C3 64

66 TABLE C4 : TWIN AND MULTICORE CABLES Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Fire retardant Protective Tape Binder Tape : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with IS : : Electron Beam Cross Linked Silicone Rubber Compound : Glass Braid / Lacquer : Glass Mica Tape : Electron Beam Cross Linked Polyolefin Compound Test Voltage Bending Radius(Min) Flexing Fixed ISO OHSAS : - 30 C to +10 C : 440 V : kv : 10 x Cable Diameter : 4 x Cable Diameter Siechem Twin and Multicore Marine Cables A A A A A A A A A A A A1 C X C X C X C X C x C x C x C x C x C x C x C x A A A A A A1 C X 1 3C X 1 4C X 1 5C X 1 7C x 1 10C x 1 14C x 1 18C x 1 4C x 1 30C x 1 36C x 1 44C x 1 C X1.5 3C X1.5 4C x 1.5 5C x 1.5 7C x C x C x C x

67 A A1 4C x C x A1 36C x A1 44C x C x C x C x C x C x C x C x C x C x C x C x.5 44C x.5 C X 4.0 3C X 4.0 4C X 4.0 5C X 4.0 7C X C X C X C X 4.0 4C X C X C X EED C4 66

68 TABLE C5 : MULTIPAIRED CABLES COLLECTIVELY SCREENED Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Fire retardant Protective Tape Binder Tape Pairs Laid up Separator Tape Braiding Separator Tape : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with IS : : Electron Beam Cross Linked Silicone Rubber Compound : Glass Braid / Lacquer : Polyester Tape : Polyester Tape : Annealed Tinned Copper braid (95% coverage) : Polyester Tape : Electron Beam Cross Linked Polyolefin Compound Test Voltage Bending Radius(Min) Flexing Fixed ISO OHSAS : - 30 C to +10 C : 440 V : kv : 10 x Cable Diameter : 4 x Cable Diameter Siechem Multipaired Cables Collectively Screened Marine Cables A A A A A A A A P x 0.75 P x P x P x P x P x P x P x P x 1 P x 1 3P x 1 4P x 1 7P x 1 11P x 1 16P x P x EED C5 67

69 TABLE C6 : MULTICORE CABLES INDIVIDUALLY SCREENED CORES Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Fire retardant Protective Tape Braiding Binder Tape Cores Laid up Separator Tape : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with IS : : Electron Beam Cross Linked Silicone Rubber Compound : Glass Braid / Lacquer : Annealed Tinned Copper braid (95% coverage) : Polyester Tape : Polyester Tape : Electron Beam Cross Linked Polyolefin Compound Test Voltage Bending Radius(Min) Flexing Fixed ISO OHSAS : - 30 C to +10 C : 440 V : kv : 10 x Cable Diameter : 4 x Cable Diameter Siechem Multicore Cables Individually Screened Cores Marine Cables A A A A A C x C x C x C x C x C x 1.0 5C x 1.0 7C x C x C x EED C6 68

70 TABLE C7 : MULTIPAIRED, CABLES, PAIRS INDIVIDUALLY SCREENED Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Fire retardant Protective Tape Separator Tape Braiding Binder Tape Pairs Laid up Separator Tape : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with IS : : Electron Beam Cross Linked Silicone Rubber Compound : Glass Braid / Lacquer : Polyester Tape : Annealed Tinned Copper braid (95% coverage) : Polyester Tape : Polyester Tape : Electron Beam Cross Linked Polyolefin Compound Test Voltage Bending Radius(Min) Flexing Fixed ISO OHSAS : - 30 C to +10 C : 440 V : kv : 10 x Cable Diameter : 4 x Cable Diameter Siechem Multipaired, Cables, Pairs Individually Screened Marine Cables A A A A P X P X P X P X P X 1 3P X 1 4P X 1 7P X EED C7 69

71 TABLE C8 : MULTICORE CABLES, COLLECTIVELY SCREENED Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Fire retardant : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with IS : : Electron Beam Cross Linked Silicone Rubber Compound Protective Tape : Glass Braid / Lacquer Separator Tape : Polyester Tape Braiding : Annealed Tinned Copper braid (95% coverage) Separator Tape : Polyester Tape : Electron Beam Cross Linked Polyolefin Compound Test Voltage Bending Radius(Min) Flexing Fixed ISO OHSAS : - 30 C to +10 C : 440 V : kv : 10 x Cable Diameter : 4 x Cable Diameter Siechem Multicore Cables, Collectively Screened Marine Cables A A A A A A A C x C x C x C x 0.75 C x 1.0 8C x 1.0 1C x C x 1.0 4C x 1.5 4C x.5 C x.5 C x 4.0 C x 6 C x A C x C x 1.5 6C x 1 8C x EED C8 70

72 TABLE C9 : MINIATURE MULTICORE CABLES, UNSCREENED (OR) INDIVIDUALLY (OR) COLLECTIVELY SCREENED Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Fire retardant Protective Tape Separator Tape Braiding Separator Tape Cores Laid up Separator Tape Braiding Separator Tape : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with IS : : Electron Beam Cross Linked Silicone Rubber Compound : Glass Braid / Lacquer : Polyester Tape : Annealed Tinned Copper braid (95% coverage) : Polyester Tape : Polyester Tape : Annealed Tinned Copper braid (95% coverage) : Polyester Tape : Electron Beam Cross Linked Polyolefin Compound Test Voltage Bending Radius(Min) Flexing Fixed ISO OHSAS : - 30 C to +10 C : 440 V : kv : 10 x Cable Diameter : 4 x Cable Diameter Siechem Miniature Multicore Cables, Unscreened (Or) Individually (Or) Collectively Screened Marine Cables C x 0.35 C x 0.35 C x C x C x C x C x C x C x C x C x C x C x C x C x C x C x C x C x C x C x C x C x C x EED C9 71

73 TABLE C10 : MINIATURE PAIR AND TRIPLE CABLES, COLLECTIVELY SCREENED Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Fire retardant : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with IS : : Electron Beam Cross Linked Silicone Rubber Compound Protective Tape : Glass Braid / Lacquer Separator Tape : Polyester Tape Pairs/Triples Laid up Braiding : Annealed Tinned Copper braid (95% coverage) : Electron Beam Cross Linked Polyolefin Compound Test Voltage Bending Radius(Min) Flexing Fixed ISO OHSAS : - 30 C to +10 C : 440 V : kv : 10 x Cable Diameter : 4 x Cable Diameter Siechem Miniature Pair and Triple Cables, Collectively Screened Marine Cables P X 0.35 P X P X P X P X P X T X 0.35 T X T X T X T X EED C10 7

74 TABLE C11 : MINIATURE MULTICORE CABLES, INDIVIDUALLY AND COLLECTIVELY SCREENED CORES Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Fire retardant Protective Tape Braiding Separator Tape Cores Laid up Separator Tape Braiding : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with IS : : Electron Beam Cross Linked Silicone Rubber Compound : Glass Braid / Lacquer : Annealed Tinned Copper braid (95% coverage) : Polyester Tape : Polyester Tape : Annealed Tinned Copper braid (95% coverage) : Electron Beam Cross Linked Polyolefin Compound Test Voltage Bending Radius(Min) Flexing Fixed ISO OHSAS : - 30 C to +10 C : 440 V : kv : 10 x Cable Diameter : 4 x Cable Diameter Siechem Miniature Multicore Cables, Individually and Collectively Screened Cores C x C x C x C x EED C11 73

75 TABLE C1 : TWIN AND THREE CORE CABLES, OVERALL SCREENED Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Fire retardant : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with IS : : Electron Beam Cross Linked Silicone Rubber Compound Protective Tape : Glass Braid / Lacquer Cores Laid up Separator Tape : Glass Mica Tape : Electron Beam Cross Linked Polyolefin Compound Braiding : Annealed Tinned Copper braid (95% coverage) Test Voltage Bending Radius(Min) Flexing Fixed ISO OHSAS : - 30 C to +10 C : 440 V : kv : 10 x Cable Diameter : 4 x Cable Diameter Siechem Twin and Three Core Cables, Overall Screened Marine Cable A1S S S S S S S S S S S S C x 0.75 C x 1 C x 1.5 C x.5 C x 4 C x 6 C x 10 C x 16 C x 5 C x 35 C x 50 C x S C x A1S S S S S S S S S S S S S S 3C x C x 1 3C x 1.5 3C x.5 3C x 4 3C x 6 3C x 10 3C x 16 3C x 5 3C x 35 3C x 50 3C x 70 3C x 95 3C x S 3C x S 3C x S 3C x EED C1 74

76 TABLE C13 : MULTICORE CABLES, OVERALL SCREENED Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Fire retardant : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with IS : : Electron Beam Cross Linked Silicone Rubber Compound Protective Tape : Glass Braid / Lacquer Cores Laid up Separator Tape : Glass Mica Tape : Electron Beam Cross Linked Polyolefin Compound Braiding : Annealed Tinned Copper braid (95% coverage) Test Voltage Bending Radius(Min) Flexing Fixed ISO OHSAS : - 30 C to +10 C : 440 V : kv : 10 x Cable Diameter : 4 x Cable Diameter Siechem Multicore Cables, Overall Screened Marine Cable A A A A C x 10 7C x 16 7C x 5 7C x 35 7C x 50 7C x 70 14C x.5 14C x 4 14C x 6 14C x 10 14C x 16 14C x 5 14C x 35 18C x 4 18C x 6 18C x 10 18C x 16 30C x 1 30C x C x.5 30C x 4 30C x 6 30C x A1S A1S A1S A1S A1S A1S A1S A1S A1S C x C x C x C x C x C x C x C x C x

77 A1S 30C x A1S 36C x A1S 44C x S C x S 3C x S 4C x S S S 5C x 1 7C x 1 10C x S 14C x S 18C x S 4C x S 30C x S 36C x S 44C x S C x S 3C x A1S 4C x A1S 5C x A1S 7C x A1S 10C x A1S 14C x A1S 18C x A1S 4C x A1S 30C x A1S A1S 36C x C x EED C13 76

78 EED 50-1 Table 1 : Multipair Cables - Collectively Screened - 0.mm Table : Individually Screened Plus Unscreened Quad Cables, Collectively Screened - 0. mm Table 3 : Multipair Individually Screened Plus Unscreened Multipair Cables, Collectively Screened - 0.6mm, 600V Table 4 : Multipair Individually Screened Plus Unscreened Multipair Cables - 0.6mm, 600V Table 5 : Multiquad Individually Screened Cables, Collectively - 0.mm, 600V Table 6 : 5 Core Cable, 1 Pair Individually Screened - 0.6mm, 600V Table 7 : Multicore Cable, Collectively Screened mm, 600V Table 8 : Multicore Cable, Collectively Screened - 0.6mm, 600V Table 9 : Multicore Cable, Collectively Screened - 1.mm, 600V Table 10 : Multicore Cable, Double Collectively Screened - 0.6mm, 600V Table 11 : Multicore Cable, Double Individual Screens and Collectively Screened - 0.6mm, 600V Table 1 : Multipair Cables, Individual Screens and Collective Super Screen mm, 600V Table 13 : Multicore Cables - Unscreened - 0.mm, 600V Table 14 : Multicore Cables - Unscreened mm, 600V Table 15 : Multicore Cables - Unscreened - 0.5mm, 600V Table 16 : Multicore Cables - Unscreened mm, 600V Table 17 : Multicore Cables - Unscreened mm, 600V Table 18 : Multicore Cables - Unscreened - 1.5mm and.5mm, 600V Table 19 : Multicore Cables - Extra thin wall insulated, Collectively Screened mm, 600V Table 0 : Multicore Cables - Unscreened - 1.5mm and.5mm, 600V Table 1 : Multipair Cables - Collectively Screened mm, 600V Table : Multipair Cables - Collectively Screened mm, 600V Table 3 : Multipair Cables - Individually Screened mm, 600V Table 4 : Multipair Cables - Individually Screened mm, 600V Table 5 : Single Core Cables (Unscreened) - 600V Table 6 : Two Core Cables (Unscreened) - 600V Table 7 : Three Core Cables (Unscreened) - 600V Table 8 : Multicore Cables - Unscreened, 600V Table 9 : Single and Multicore Cables - Collectively Screened, 600V Table 30 : Single and Multipair Cables - Collectively Screened, 600V Table 31 : Multipair Cables, Individually Screened, 600V Table 3 : Single and Multitriad, Collectively Screened, 600V Table 33 : Single and Multitriad, Individually Screened, 600V Table 34 : Singlecore Cables with Screen Oversheath, 600V Table 35 : Multicore with Screen Oversheath, 600V Table 36 : Singlecore Cables, Low Capacitance, 600V Table 37 : Multicore Cables Cores individually Screened, 600V Table 38 : Multicore Cables Cores Individually / Collectively Screened, 600V Table 39 : Singlecore Cables (Unscreened, Shore Supply), 1800V Table 40 : Overall Screened Cables 77

79 TABLE 1 : MULTIPAIR CABLES - COLLECTIVELY SCREENED 0.mm Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Fire retardant : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with IS : : Electron Beam Cross Linked Polyolefin Compound Pairs Laid up Braiding : Annealed Tinned Copper braid (95% coverage) Separator Tape : Polyester tape : Electron Beam Cross Linked Polyolefin Compound Test Voltage Bending Radius(Min) Flexing Fixed ISO OHSAS : - 65 C to +10 C : 600 V : 1.5 kv : 10 x Cable Diameter : 4 x Cable Diameter Siechem Multipair Cables - Collectively Screened Marine Cable P x 0. P x 0. 3P x 0. 5P x / / / / EED 50-1 C1 78

80 TABLE : INDIVIDUALLY SCREENED PLUS UNSCREENED QUAD CABLES, COLLECTIVELY SCREENED 0.mm Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Fire retardant Cores Laid up Braiding Screen- Separator Tape Pairs Laid up Separator Tape Braiding Separator Tape : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with IS : : Electron Beam Cross Linked Dual layer Polyolefin Compound : Annealed Tinned Copper braid (95% coverage) : Electron Beam Cross Linked Polyolefin Compound : Polyester tape (Over unscreened quad) : Polyethylene teraphthalate (PTP) : Annealed Tinned Copper braid (95% coverage) : Polyester tape : Electron Beam Cross Linked Polyolefin Compound Test Voltage Bending Radius(Min) Flexing Fixed ISO OHSAS : - 65 C to +10 C : 600 V : 1.5 kv : 10 x Cable Diameter : 4 x Cable Diameter Siechem Individually Screened Plus Unscreened Quad Cables, Collectively Screened Marine Cable P x / EED 50-1 C 79

81 TABLE 3 : MULTIPAIR INDIVIDUALLY SCREENED PLUS UNSCREENED MULTIPAIR CABLES, COLLECTIVELY SCREENED - 0.6mm Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Fire retardant : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with IS : : Electron Beam Cross Linked Dual layer Polyolefin Compound Cores Laid up Braiding : Annealed Tinned Copper braid (95% coverage) Screen- : Electron Beam Cross Linked Polyolefin Compound Pairs Laid up Separator Tape : Polyester tape Braiding : Annealed Tinned Copper braid (95% coverage) : Electron Beam Cross Linked Polyolefin Compound Test Voltage Bending Radius(Min) Flexing Fixed ISO OHSAS : - 65 C to +10 C : 600 V : 1.5 kv : 10 x Cable Diameter : 4 x Cable Diameter Siechem Multipair Individually Screened Plus Unscreened Multipair Cables, Collectively Screened Marine Cable P x / EED 50-1 C3 80

82 TABLE 4 : MULTIPAIR INDIVIDUALLY SCREENED PLUS UNSCREENED MULTIPAIR CABLES - 0.6mm, 600V Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Fire retardant : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with IS : : Electron Beam Cross Linked Dual layer Polyolefin Compound Cores Laid up Braiding : Annealed Tinned Copper braid (95% coverage) Screen- : Electron Beam Cross Linked Polyolefin Compound Pairs Laid up Separator Tape : Polyester tape : Electron Beam Cross Linked Polyolefin Compound Test Voltage Bending Radius(Min) Flexing Fixed ISO OHSAS : - 65 C to +10 C : 600 V : 1.5 kv : 10 x Cable Diameter : 4 x Cable Diameter Siechem Multipair Individually Screened Plus Unscreened Multipair Marine cable P x / EED C4 81

83 TABLE 5 : MULTIQUAD INDIVIDUALLY SCREENED CABLES - 0.mm, 600V Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Fire retardant Cores Laid up Separator Tape Braiding Screen- Quads Laid up :Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with IS : : Electron Beam Cross Linked Dual layer Polyolefin Compound : Polyester Tape : Annealed Tinned Copper braid (95% coverage) : Electron Beam Cross Linked Polyolefin Compound : Electron Beam Cross Linked Polyolefin Compound Test Voltage Bending Radius(Min) Flexing Fixed ISO OHSAS : - 65 C to +10 C : 600 V : 1.5 kv : 10 x Cable Diameter : 4 x Cable Diameter Siechem Multiquad Individually Screened Cables Marine Cable q x / EED C5 8

84 TABLE 6 : 5 CORE CABLE, 1 PAIR INDIVIDUALLY SCREENED - 0.6mm, 600V Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Fire retardant : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with IS : : Electron Beam Cross Linked Dual layer Polyolefin Compound Cores Laid up Separator Tape : Polyester Tape Braiding : Annealed Tinned Copper braid (95% coverage) Separator Tape : Polyester Tape Cores & Pairs Laid up : Electron Beam Cross Linked Polyolefin Compound Test Voltage Bending Radius(Min) Flexing Fixed ISO OHSAS : - 65 C to +10 C : 600 V : 1.5 kv : 10 x Cable Diameter : 4 x Cable Diameter Siechem Table 1P C Core x Cable, 0. 1 Pair Individually Screened Marine Cable 6.6/ EED 50-1 C6 83

85 TABLE 7 : MULTICORE CABLE, COLLECTIVELY SCREENED mm, 600V Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Fire retardant Cores Laid up Separator Tape Braiding Separator Tape : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with IS : : Electron Beam Cross Linked Dual layer Polyolefin Compound : Polyester Tape : Annealed Tinned Copper braid (95% coverage) : Polyester Tape : Electron Beam Cross Linked Polyolefin Compound Test Voltage Bending Radius(Min) Flexing Fixed ISO OHSAS : - 65 C to +10 C : 600 V : 1.5 kv : 10 x Cable Diameter : 4 x Cable Diameter Siechem Multicore Cable, Collectively Screened Marine Cable C x / EED 50-1 C7 84

86 TABLE 8 : MULTICORE CABLE, COLLECTIVELY SCREENED - 0.6mm, 600V Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Fire retardant Cores Laid up Separator Tape Braiding Separator Tape : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with IS : : Electron Beam Cross Linked Dual layer Polyolefin Compound : Polyester Tape : Annealed Tinned Copper braid (95% coverage) : Polyester Tape : Electron Beam Cross Linked Polyolefin Compound Test Voltage Bending Radius(Min) Flexing Fixed ISO OHSAS : - 65 C to +10 C : 600 V : 1.5 kv : 10 x Cable Diameter : 4 x Cable Diameter Siechem Multicore Cable, Collectively Screened Marine Cable C x / EED 50-1 C8 85

87 TABLE 9 : MULTICORE CABLE, COLLECTIVELY SCREENED - 1.mm, 600V Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Fire retardant Cores Laid up Separator Tape Braiding Separator Tape : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with IS : : Electron Beam Cross Linked Dual layer Polyolefin Compound : Polyester Tape : Annealed Tinned Copper braid (95% coverage) : Polyester Tape : Electron Beam Cross Linked Polyolefin Compound Test Voltage Bending Radius(Min) Flexing Fixed ISO OHSAS : - 65 C to +10 C : 600 V : 1.5 kv : 10 x Cable Diameter : 4 x Cable Diameter Siechem Multicore Cable, Collectively Screened Marine Cable C x / EED 50-1 C9 86

88 TABLE 10 : MULTICORE CABLE, DOUBLE COLLECTIVELY SCREENED - 0.6mm, 600V Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Fire retardant Cores Laid up Separator Tape Braiding Braiding Separator Tape : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with IS : : Electron Beam Cross Linked Dual layer Polyolefin Compound : Polyester Tape : Annealed Tinned Copper braid (95% coverage) : Annealed Tinned Copper braid (95% coverage) : Polyester Tape : Electron Beam Cross Linked Polyolefin Compound Test Voltage Bending Radius(Min) Flexing Fixed ISO OHSAS : - 65 C to +10 C : 600 V : 1.5 kv : 10 x Cable Diameter : 4 x Cable Diameter Siechem Multicore Cable, Double Collectively Screened Marine Cable C x 0.5 6C x 0.5 C x / / / EED 50-1 C10 87

89 TABLE 11 : MULTIPAIR CABLES, DOUBLE INDIVIDUAL SCREENS AND COLLECTIVELY SCREENED - 0.6mm, 600V Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Fire retardant Cores Laid up Braiding Braiding Pairs Laid up Braiding Separator Tape : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with IS : : Electron Beam Cross Linked Dual layer Polyolefin Compound : Annealed Tinned Copper braid (95% coverage) : Annealed Tinned Copper braid (95% coverage) : Annealed Tinned Copper braid (95% coverage) : Polyester Tape : Electron Beam Cross Linked Polyolefin Compound Test Voltage Bending Radius(Min) Flexing Fixed ISO OHSAS : - 65 C to +10 C : 600 V : 1.5 kv : 10 x Cable Diameter : 4 x Cable Diameter Siechem Multicore Cable, Double Individual Screens and Collectively Screened Marine Cable P x P x / / EED 50-1 C11 88

90 TABLE 1 : : MULTIPAIR CABLES, INDIVIDUAL SCREENS AND COLLECTIVE SUPER SCREEN mm, 600V Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Fire retardant Pairs Laid up Braiding Separator Tape Braiding Separator Tape : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with IS : : Electron Beam Cross Linked Dual layer Polyolefin Compound : Annealed Tinned Copper braid (95% coverage) : Metal Tape : Annealed Tinned Copper braid (95% coverage) : Polyester Tape : Electron Beam Cross Linked Polyolefin Compound Test Voltage Bending Radius(Min) Flexing Fixed ISO OHSAS : - 65 C to +10 C : 600 V : 1.5 kv : 10 x Cable Diameter : 4 x Cable Diameter Siechem Multipair Cables, Individual Screens and Collective Super Screen Marine Cable P x / EED 50-1 C1 89

91 TABLE 13 : MULTICORE CABLES - UNSCREENED - 0.mm, 600V Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Fire retardant Cores Laid up Separator Tape : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with IS : : Electron Beam Cross Linked Dual layer Polyolefin Compound : Polyester Tape : Electron Beam Cross Linked Polyolefin Compound Test Voltage Bending Radius(Min) Flexing Fixed ISO OHSAS : - 65 C to +10 C : 600 V : 1.5 kv : 10 x Cable Diameter : 4 x Cable Diameter Siechem Multicore Cables - Unscreened Marine Cable C x 0. 7C x 0. 14C x 0. 4C x 0. 37C x 0. 44C x / / / / / / EED 50-1 C13 90

92 TABLE 14 : MULTICORE CABLES - UNSCREENED mm, 600V Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Fire retardant Cores Laid up Separator Tape : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with IS : : Electron Beam Cross Linked Dual layer Polyolefin Compound : Polyester Tape : Electron Beam Cross Linked Polyolefin Compound Test Voltage Bending Radius(Min) Flexing Fixed ISO OHSAS : - 65 C to +10 C : 600 V : 1.5 kv : 10 x Cable Diameter : 4 x Cable Diameter Siechem Multicore Cables - Unscreened Marine Cable C x C x C x C x C x C x C x / / / / / / / EED 50-1 C14 91

93 TABLE 15 : MULTICORE CABLES - UNSCREENED - 0.5mm, 600V Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Fire retardant Cores Laid up Separator Tape : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with IS : : Electron Beam Cross Linked Dual layer Polyolefin Compound : Polyester Tape : Electron Beam Cross Linked Polyolefin Compound Test Voltage Bending Radius(Min) Flexing Fixed ISO OHSAS : - 65 C to +10 C : 600 V : 1.5 kv : 10 x Cable Diameter : 4 x Cable Diameter Siechem Multicore Cables - Unscreened Marine Cable C x 0.5 7C x C x C x 0.5 4C x C x / / /9.0 8./ / / EED 50-1 C15 9

94 TABLE 16 : MULTICORE CABLES - UNSCREENED mm, 600V Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Fire retardant Cores Laid up Separator Tape : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with IS : : Electron Beam Cross Linked Dual layer Polyolefin Compound : Polyester Tape : Electron Beam Cross Linked Polyolefin Compound Test Voltage Bending Radius(Min) Flexing Fixed ISO OHSAS : - 65 C to +10 C : 600 V : 1.5 kv : 10 x Cable Diameter : 4 x Cable Diameter Siechem Multicore Cables - Unscreened Marine Cable C x C x C x C x C x C x C x C x C x / /6. 5.4/ / / / / / / EED 50-1 C16 93

95 TABLE 17 : MULTICORE CABLES - UNSCREENED mm, 600V Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Fire retardant Cores Laid up Separator Tape : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with IS : : Electron Beam Cross Linked Dual layer Polyolefin Compound : Polyester Tape : Electron Beam Cross Linked Polyolefin Compound Test Voltage Bending Radius(Min) Flexing Fixed ISO OHSAS : - 65 C to +10 C : 600 V : 1.5 kv : 10 x Cable Diameter : 4 x Cable Diameter Siechem Multicore Cables - Unscreened Marine Cable C x 1.0 3C x 1.0 7C x C x 1.0 4C x / / / / / EED 50-1 C17 94

96 TABLE 18 : MULTICORE CABLES - UNSCREENED - 1.5mm and.5mm, 600V Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Fire retardant Cores Laid up Separator Tape : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with IS : : Electron Beam Cross Linked Dual layer Polyolefin Compound : Polyester Tape : Electron Beam Cross Linked Polyolefin Compound Test Voltage Bending Radius(Min) Flexing Fixed ISO OHSAS : - 65 C to +10 C : 600 V : 1.5 kv : 10 x Cable Diameter : 4 x Cable Diameter Siechem Multicore Cables - Unscreened Marine Cable C x 1.5 3C x 1.5 7C x C x 1.5 4C x / / / / / EED 50-1 C18 95

97 TABLE 19 : MULTICORE CABLES - EXTRA THIN WALL INSULATED, COLLECTIVELY SCREENED mm, 600V Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Fire retardant Cores Laid up Separator Tape Braiding Separator Tape : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with IS : : Electron Beam Cross Linked Dual layer Polyolefin Compound : Polyester Tape : Annealed Tinned Copper braid (95% coverage) : Polyester Tape : Electron Beam Cross Linked Polyolefin Compound Test Voltage Bending Radius(Min) Flexing Fixed ISO OHSAS : - 65 C to +10 C : 600 V : 1.5 kv : 10 x Cable Diameter : 4 x Cable Diameter Siechem Multicore Cables - Extra thin wall insulated, Collectively Screened Marine Cable x x x x x x x x x x / / / / / / / / / / EED 50-1 C19 96

98 TABLE 0 : MULTICORE CABLES - COLLECTIVELY SCREENED mm, 600V Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Fire retardant Cores Laid up Separator Tape Braiding Separator Tape : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with IS : : Electron Beam Cross Linked Dual layer Polyolefin Compound : Polyester Tape : Annealed Tinned Copper braid (95% coverage) : Polyester Tape : Electron Beam Cross Linked Polyolefin Compound Test Voltage Bending Radius(Min) Flexing Fixed ISO OHSAS : - 65 C to +10 C : 600 V : 1.5 kv : 10 x Cable Diameter : 4 x Cable Diameter Siechem Multicore Cables - Collectively Screened Marine Cable x x 0.75 x x x x x x 0.75 x x / / / /8. 7./ / / / / / EED 50-1 C0 97

99 TABLE 1 : MULTIPAIR CABLES - COLLECTIVELY SCREENED mm, 600V Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Fire retardant Pairs Laid up Separator Tape Braiding : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with IS : : Electron Beam Cross Linked Dual layer Polyolefin Compound : Polyester Tape : Annealed Tinned Copper braid (95% coverage) : Electron Beam Cross Linked Polyolefin Compound Test Voltage Bending Radius(Min) Flexing Fixed ISO OHSAS : - 65 C to +10 C : 600 V : 1.5 kv : 10 x Cable Diameter : 4 x Cable Diameter Siechem Multipair Cables - Collectively Screened Marine Cable P x P x P x P x P x P x P x P x / / / / / / / / EED 50-1 C1 98

100 TABLE : MULTIPAIR CABLES - COLLECTIVELY SCREENED mm, 600V Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Fire retardant Pairs Laid up Separator Tape Braiding : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with IS : : Electron Beam Cross Linked Dual layer Polyolefin Compound : Polyester Tape : Annealed Tinned Copper braid (95% coverage) : Electron Beam Cross Linked Polyolefin Compound Test Voltage Bending Radius(Min) Flexing Fixed ISO OHSAS : - 65 C to +10 C : 600 V : 1.5 kv : 10 x Cable Diameter : 4 x Cable Diameter Siechem Multipair Cables - Collectively Screened Marine Cable P x P x P x P x P x P x P x / / / / / / / EED 50-1 C 99

101 TABLE 3 : : MULTIPAIR CABLES - INDIVIDUALLY SCREENED mm, 600V Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Fire retardant : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with IS : : Electron Beam Cross Linked Polyolefin Compound Cores Laid up Braiding : Annealed Tinned Copper braid (95% coverage) Pairs Laid up Separator Tape : Polyester tape : Electron Beam Cross Linked Polyolefin Compound Test Voltage Bending Radius(Min) Flexing Fixed ISO OHSAS : - 65 C to +10 C : 600 V : 1.5 kv : 10 x Cable Diameter : 4 x Cable Diameter Siechem Multipair Cables - Individually Screened Marine Cable P x P x P x P x / / / / EED 50-1 C3 100

102 TABLE 4 : MULTIPAIR CABLES - INDIVIDUALLY SCREENED mm, 600V Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Fire retardant : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with IS : : Electron Beam Cross Linked Polyolefin Compound Cores Laid up Braiding : Annealed Tinned Copper braid (95% coverage) Pairs Laid up Separator Tape : Polyester tape : Electron Beam Cross Linked Polyolefin Compound Test Voltage Bending Radius(Min) Flexing Fixed ISO OHSAS : - 65 C to +10 C : 600 V : 1.5 kv : 10 x Cable Diameter : 4 x Cable Diameter Siechem Multipair Cables - Individually Screened Marine Cable P x P x P x P x / / / / EED 50-1 C4 101

103 TABLE 5 : SINGLE CORE CABLES (UNSCREENED) - 600V Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with IS : : Electron Beam Cross Linked Dual layer Polyolefin Compound : Electron Beam Cross Linked Polyolefin Compound Test Voltage Bending Radius(Min) Flexing Fixed : - 65 C to +10 C : 600 V : 1.5 kv : 10 x Cable Diameter : 4 x Cable Diameter ISO OHSAS Fire retardant Siechem Single Core Cables (Unscreened) Marine Cable C x 0.5 1C x C x 1.0 1C x 1.5 1C x.5 1C x 4 1C x 6 1C x 10 1C x 16 1C x 5 1C x 35 1C x 50 1C x 70 1C x 95 1C x 10 1C x 150 1C x 185 1C x 40 1C x 300 1C x 400 1C x 500 1C x EED 50-1 C5 10

104 TABLE 6 : TWO CORE CABLES (UNSCREENED) - 600V Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Fire retardant Cores Laid up Separator Tape : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with IS : : Electron Beam Cross Linked Dual layer Polyolefin Compound : Polyester Tape : Electron Beam Cross Linked Polyolefin Compound Test Voltage Bending Radius(Min) Flexing Fixed ISO OHSAS : - 65 C to +10 C : 600 V : 1.5 kv : 10 x Cable Diameter : 4 x Cable Diameter Siechem Two Core Cables (Unscreened) Marine Cable C x 0.5 C x 0.75 C x 1.0 C x 1.5 C x.5 C x 4 C x 6 C x 10 C x 16 C x 5 C x 35 C x 50 C x 70 C x 95 C x 10 C x EED 50-1 C6 103

105 TABLE 7 : THREE CORE CABLES (UNSCREENED) - 600V Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Fire retardant Cores Laid up Separator Tape : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with IS : : Electron Beam Cross Linked Dual layer Polyolefin Compound : Polyester Tape : Electron Beam Cross Linked Polyolefin Compound Test Voltage Bending Radius(Min) Flexing Fixed ISO OHSAS : - 65 C to +10 C : 600 V : 1.5 kv : 10 x Cable Diameter : 4 x Cable Diameter Siechem Three Core Cables (Unscreened) Marine Cable C x 0.5 3C x C x 1.0 3C x 1.5 3C x.5 3C x 4 3C x 6 3C x 10 3C x 16 3C x 5 3C x 35 3C x 50 3C x 70 3C x 95 3C x 10 3C x 150 3C x 185 3C x EED 50-1 C7 104

106 TABLE 8 : MULTICORE CABLES - UNSCREENED, 600V Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Fire retardant Cores Laid up Separator Tape : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with IS : : Electron Beam Cross Linked Dual layer Polyolefin Compound : Polyester Tape : Electron Beam Cross Linked Polyolefin Compound Test Voltage Bending Radius(Min) Flexing Fixed ISO OHSAS : - 65 C to +10 C : 600 V : 1.5 kv : 10 x Cable Diameter : 4 x Cable Diameter Siechem Multicore Cables - Unscreened Marine Cable * C x 0.5 4C x C x 1.0 4C x 1.5 4C x.5 4C x 4 5C x 0.5 5C x 1.0 5C x.5 5C x 4 6C x 6 7C x 0.5 7C x 1.0 7C x.5 7C x 4 7C x 6 7C x 10 7C x 16 7C x 5 7C x 35 7C x 50 7C x 70 8C x 0.5 8C x 1.5 8C x.5 8C x 4 10C x C x C x.5 10C x 4.0 1C x C x C x

107 C x C x C x 10 14C x 16 14C x 5 14C x 35 18C x C x.5 18C x C x C x 10 18C x 16 19C x C x 1.0 C x 1.5 C x.5 4C x 1.0 4C x 1.5 4C x.5 4C x 4 7C x C x C x C x.5 30C x 4 30C x 6 30C x 10 36C x C x.5 36C x C x C x C x C x EED 50-1 C8 106

108 TABLE 9 : SINGLE AND MULTICORE CABLES - COLLECTIVELY SCREENED, 600V Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Fire retardant Cores Laid up Separator Tape Braiding Separator Tape : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with IS : : Electron Beam Cross Linked Dual layer Polyolefin Compound : Polyester Tape : Annealed Tinned Copper braid (95% coverage) : Polyester Tape : Electron Beam Cross Linked Polyolefin Compound Test Voltage Bending Radius(Min) Flexing Fixed ISO OHSAS : - 65 C to +10 C : 600 V : 1.5 kv : 10 x Cable Diameter : 4 x Cable Diameter Siechem Single and Multicore Cables - Collectively Screened Marine Cable * x 1 4 x x.5 4 x 6 5 x 1 5 x x x x x x 1 1 x x x 1 14 x x x x x x x x 35 3 x 50 3 x 70 3 x 95 3 x 10 3 x x x x 10 1 x

109 x x x x x x x x x x x x x x x x 10 3 x 16 3 x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x

110 x x 1 1 x x x 1 14 x 1 14 x x x x 50 x 70 x 95 x 10 x x 50 3 x 70 3 x 95 3 x 10 3 x x x EED 50-1 C9 109

111 TABLE 30 : SINGLE AND MULTIPAIR CABLES - COLLECTIVELY SCREENED, 600V Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Fire retardant Pairs Laid up Separator Tape Braiding : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with IS : : Electron Beam Cross Linked Dual layer Polyolefin Compound : Polyester Tape : Annealed Tinned Copper braid (95% coverage) : Electron Beam Cross Linked Polyolefin Compound Test Voltage Bending Radius(Min) Flexing Fixed ISO OHSAS : - 65 C to +10 C : 600 V : 1.5 kv : 10 x Cable Diameter : 4 x Cable Diameter Siechem Single and Multipair Cables - Collectively Screened Marine Cables P x 0.5 P x 0.5 5P x 0.5 9P x P x P x 0.6 P x 0.6 3P x 0.6 4P x 0.6 7P x P x P x P x P x P x 0.75 P x P x P x P x P x P x P x P x P x P x P x P x P x P x

112 P x P x EED 50-1 C30 111

113 TABLE 31 : MULTIPAIR CABLES, INDIVIDUALLY SCREENED, 600V Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Fire retardant : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with IS : : Electron Beam Cross Linked Polyolefin Compound Cores Laid up Braiding : Annealed Tinned Copper braid (95% coverage) Pairs Laid up Separator Tape : Polyester tape : Electron Beam Cross Linked Polyolefin Compound Test Voltage Bending Radius(Min) Flexing Fixed ISO OHSAS : - 65 C to +10 C : 600 V : 1.5 kv : 10 x Cable Diameter : 4 x Cable Diameter Siechem Multipair Cables, Individually Screened Marine Cable P X 0.5 5P X 0.5 9P X P X 0.5 3P X 0.6 4P X 0.6 7P X 0.6 3P X 1 4P X 1 7P X EED 50-1 C31 11

114 TABLE 3 : SINGLE AND MULTITRIAD, COLLECTIVELY SCREENED, 600V Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Fire retardant Triads Laid up Braiding Separator Tape : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with IS : : Electron Beam Cross Linked Dual layer Polyolefin Compound : Annealed Tinned Copper braid (95% coverage) : Polyester Tape : Electron Beam Cross Linked Polyolefin Compound Test Voltage Bending Radius(Min) Flexing Fixed ISO OHSAS : - 65 C to +10 C : 600 V : 1.5 kv : 10 x Cable Diameter : 4 x Cable Diameter Siechem Single and Multitriad, Collectively Screened Marine Cable T X 0.5 3T X 0.5 7T X EED 50-1 C3 113

115 TABLE 33 : SINGLE AND MULTITRIAD, INDIVIDUALLY SCREENED, 600V Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Fire retardant Cores Laid up Separator Tape Braiding Separator Tape Triads Laid up Separator Tape : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with IS : : Electron Beam Cross Linked Polyolefin Compound : Polyester tape : Annealed Tinned Copper braid (95% coverage) : Polyester tape : Polyester Tape : Electron Beam Cross Linked Polyolefin Compound Test Voltage Bending Radius(Min) Flexing Fixed ISO OHSAS : - 65 C to +10 C : 600 V : 1.5 kv : 10 x Cable Diameter : 4 x Cable Diameter Siechem Single and Multitriad, Individually Screened Marine Cable T X 0.5 3T X 0.5 7T X EED 50-1 C33 114

116 TABLE 34 : SINGLECORE CABLES WITH SCREEN OVERSHEATH, 600V Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Braiding : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with IS : : Electron Beam Cross Linked Dual layer Polyolefin Compound : Electron Beam Cross Linked Polyolefin Compound : Annealed Tinned Copper braid (95% coverage) Test Voltage Bending Radius(Min) Flexing Fixed ISO OHSAS : - 65 C to +10 C : 600 V : 1.5 kv : 10 x Cable Diameter : 4 x Cable Diameter Fire retardant Siechem Singlecore Cables with Screen Oversheath Marine Cable C X 0.5 1C X C X 1.0 1C X 1.5 1C X.5 1C X 4 1C X EED 50-1 C34 115

117 TABLE 35 : MULTICORE WITH SCREEN OVERSHEATH, 600V Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Fire retardant Cores Laid up Separator Tape Braiding : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with IS : : Electron Beam Cross Linked Dual layer Polyolefin Compound : Polyester Tape : Electron Beam Cross Linked Polyolefin Compound : Annealed Tinned Copper braid (95% coverage) Test Voltage Bending Radius(Min) Flexing Fixed ISO OHSAS : - 65 C to +10 C : 600 V : 1.5 kv : 10 x Cable Diameter : 4 x Cable Diameter Siechem Multicore with Screen Oversheath Marine Cable C X 0.5 C X 0.75 C X 1 C X 1.5 C X.5 3C X 0.5 3C X C X 1 3C X 1.5 4C X 0.5 4C X C X 0.5 7C X EED 50-1 C35 116

118 TABLE 36 : SINGLECORE CABLES, LOW CAPACITANCE, 600V Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Fire retardant Braiding Separator Tape : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with IS : : Electron Beam Cross Linked Dual layer Polyolefin Compound : Annealed Tinned Copper braid (95% coverage) : Polyester Tape : Electron Beam Cross Linked Polyolefin Compound Test Voltage Bending Radius(Min) Flexing Fixed ISO OHSAS : - 65 C to +10 C : 600 V : 1.5 kv : 10 x Cable Diameter : 4 x Cable Diameter Siechem Singlecore Cables, Low Capacitance Marine Cable C x 1 1C x 1 1C x 1 1C x EED 50-1 C36 117

119 TABLE 37 : MULTICORE CABLES CORES INDIVIDUALLY SCREENED, 600V Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Fire retardant Separator Tape Braiding Separator Tape Cores Laid up Separator Tape : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with IS : : Electron Beam Cross Linked Dual layer Polyolefin Compound : Polyester Tape : Annealed Tinned Copper braid (95% coverage) : Polyester Tape : Polyester Tape : Electron Beam Cross Linked Polyolefin Compound Test Voltage Bending Radius(Min) Flexing Fixed ISO OHSAS : - 65 C to +10 C : 600 V : 1.5 kv : 10 x Cable Diameter : 4 x Cable Diameter Siechem Multicore Cables Cores individually Screened Marine Cable C x 0.5 5C x 0.5 7C x C x C x EED 50-1 C37 118

120 TABLE 38 : MULTICORE CABLES CORES INDIVIDUALLY / COLLECTIVELY SCREENED, 600V Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Fire retardant Separator Tape Braiding Separator Tape Cores Laid up Braiding Separator Tape : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with IS : : Electron Beam Cross Linked Dual layer Polyolefin Compound : Polyester Tape : Annealed Tinned Copper braid (95% coverage) : Polyethylene Teraphthalate : Annealed Tinned Copper braid (95% coverage) : Polyester Tape : Electron Beam Cross Linked Polyolefin Compound Test Voltage Bending Radius(Min) Flexing Fixed ISO OHSAS : - 65 C to +10 C : 600 V : 1.5 kv : 10 x Cable Diameter : 4 x Cable Diameter Siechem Multicore Cables Cores Individually / Collectively Screened Marine Cable C x C x C x C x C x 1.5 7C x EED 50-1 C38 119

121 TABLE 39 : SINGLECORE CABLES (UNSCREENED, SHORE SUPPLY), 1800V Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Separator Tape : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with IS : : Polyethylene Teraphthalate : Electron Beam Cross Linked Dual layer Polyolefin Compound : Electron Beam Cross Linked Polyolefin Compound Test Voltage Bending Radius(Min) Flexing Fixed ISO OHSAS : - 65 C to +10 C : 1.8kV : 6.0 kv : 10 x Cable Diameter : 4 x Cable Diameter Fire retardant Siechem Singlecore Cables (Unscreened, Shore Supply) Marine Cable C x 35 1C x 50 1C x 70 1C x 95 1C x 10 1C x 150 1C x 185 1C x 40 1C x EED 50-1 C39 10

122 TABLE 40 : OVERALL SCREENED CABLES Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Fire retardant Cores Laid up Separator Tape Inner Sheath Braiding Separator Tape : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with IS : : Electron Beam Cross Linked Dual layer Polyolefin Compound : Polyester Tape : Electron Beam Cross Linked Polyolefin Compound : Annealed Tinned Copper braid (95% coverage) : Polyester Tape : Electron Beam Cross Linked Polyolefin Compound Test Voltage Bending Radius(Min) Flexing Fixed ISO OHSAS : - 65 C to +10 C : 600 V : 1.5 kv : 10 x Cable Diameter : 4 x Cable Diameter Siechem Overall Screened Marine Cable x / EED 50-1 C40 11

123 NES 55 Table C1: Multicore Cables-Unscreened 0.mm² Table C: Multicore Cables-Unscreened 0.35mm² Table C3: Multicore Cables-Unscreened 0.6mm² Table C4: Multicore Cables-Unscreened 1.0mm² Table C5: Multicore Cables-Unscreened 1.5mm² Table C6: Multicore Cables-Unscreened.5mm² Table C7: Multicore Cables-Collectively screened 0.35mm² Table C8: Multicore Cables-Collectively screened 1.0mm² Table C9: Multipair Cables-Collectively screened 0.35mm² Table C10: Multipair Cables-Collectively screened 1.0mm² Table C11: Multipair Cables-Individually screened 0.35mm² Table C1: Multipair Cables-Individually screened 1.0mm² Table C13: Multipair Cables-Individually and collectively screened 0.35mm² Table C14: Multitriple Cables-Collectively screened 0.35mm² 1

124 TABLE C1 : Multicore Cables - Unscreened 0.mm Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Ship systems & equipments and weapon systems & equipments. Laying up : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with BS : 6360 : Limited Fire Hazard Compound : Limited Fire Hazard complying with NES 518 Material. Test Voltage Bending Radius Flexing Fixed ISO OHSAS : - 9 C to +85 C : 600 V : 1.5 kv : 10 x Cable Diameter : 4 x Cable Diameter Limited Fire Hazard Siechem Multicore - Unscreened Marine Cable C x 0. 7C x 0. 14C x 0. 4C x 0. 37C x 0. 44C x / / / / / / NES 55 C1 13

125 TABLE C : Multicore Cables - Unscreened 0.35mm Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Ship systems & equipments and weapon systems & equipments. Laying up : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with BS : 6360 : Limited Fire Hazard Compound : Limited Fire Hazard complying with NES 518 Material. Test Voltage Bending Radius Flexing Fixed ISO OHSAS : - 9 C to +85 C : 600 V : 1.5 kv : 10 x Cable Diameter : 4 x Cable Diameter Limited Fire Hazard Siechem Multicore - Unscreened Marine Cables C x C x C x C x C x C x C x / / / / / / / NES 55 C 14

126 TABLE C3 : Multicore Cables - Unscreened 0.6mm Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Ship systems & equipments and weapon systems & equipments. Laying up : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with BS : 6360 : Limited Fire Hazard Compound : Limited Fire Hazard complying with NES 518 Material. Test Voltage Bending Radius Flexing Fixed ISO OHSAS : - 9 C to +85 C : 600 V : 1.5 kv : 10 x Cable Diameter : 4 x Cable Diameter Limited Fire Hazard Siechem Multicore - Unscreened Marine Cables C x 0.6 7C x C x C x 0.6 4C x C x / / / / / / NES 55 C3 15

127 TABLE C4 : Multicore Cables - Unscreened 1.0mm Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Ship systems & equipments and weapon systems & equipments. Laying up : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with BS : 6360 : Limited Fire Hazard Compound : Limited Fire Hazard complying with NES 518 Material. Test Voltage Bending Radius Flexing Fixed ISO OHSAS : - 9 C to +85 C : 600 V : 1.5 kv : 10 x Cable Diameter : 4 x Cable Diameter Limited Fire Hazard Siechem Multicore - Unscreened Marine Cables C x 1.0 3C x 1.0 4C x 1.0 7C x C x C x C x 1.0 4C x C x / / / / / / / / / NES 55 C4 16

128 TABLE C5 : Multicore Cables - Unscreened 1.5mm Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Ship systems & equipments and weapon systems & equipments. Laying up : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with BS : 6360 : Limited Fire Hazard Compound : Limited Fire Hazard complying with NES 518 Material. Test Voltage Bending Radius Flexing Fixed ISO OHSAS : - 9 C to +85 C : 600 V : 1.5 kv : 10 x Cable Diameter : 4 x Cable Diameter Limited Fire Hazard Siechem Multicore - Uncreened Marine Cable C x 1.5 3C x 1.5 7C x C x 1.5 4C x / / / / / NES 55 C5 17

129 TABLE C6 : Multicore Cables - Unscreened.5mm Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Ship systems & equipments and weapon systems & equipments. Laying up : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with BS : 6360 : Limited Fire Hazard Compound : Limited Fire Hazard complying with NES 518 Material. Test Voltage Bending Radius Flexing Fixed ISO OHSAS : - 9 C to +85 C : 600 V : 1.5 kv : 10 x Cable Diameter : 4 x Cable Diameter Limited Fire Hazard Siechem Multicore - Unscreened Marine Cable C x.5 3C x.5 7C x.5 14C x.5 4C x.5 6.9/ / / / / NES 55 C6 18

130 TABLE C7 : Multicore Cables - Collectively Screened 0.35mm Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Ship systems & equipments and weapon systems & equipments. Laying up Collective Screen : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with BS : 6360 : Limited Fire Hazard Compound Test Voltage Bending Radius Flexing Fixed : Annealed Tinned Copper braid (95% Coverage) : Limited Fire Hazard complying with NES 518 Material. ISO OHSAS : - 9 C to +85 C : 600 V : 1.5 kv : 10 x Cable Diameter : 4 x Cable Diameter Limited Fire Hazard Siechem Multicore - Collectively Screened Marine Cables C x C x C x C x C x C x C x C x / / / / / / / / NES 55 C7 19

131 TABLE C8 : Multicore Cables - Collectively Screened 1.0mm Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Ship systems & equipments and weapon systems & equipments. Laying up Collective Screen : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with BS : 6360 : Limited Fire Hazard Compound Test Voltage Bending Radius Flexing Fixed : Annealed Tinned Copper braid (95% Coverage) : Limited Fire Hazard complying with NES 518 Material. ISO OHSAS : - 9 C to +85 C : 600 V : 1.5 kv : 10 x Cable Diameter : 4 x Cable Diameter Limited Fire Hazard Siechem Multicore - Collectively Screened Marine Cables C x 1.0 3C x 1.0 7C x C x / / / / NES 55 C8 130

132 TABLE C9 : Multipair Cables - Collectively Screened 0.35mm Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Ship systems & equipments and weapon systems & equipments. Pairs laid up Collective Screen : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with BS : 6360 : Limited Fire Hazard Compound Test Voltage Bending Radius Flexing Fixed : Annealed Tinned Copper braid (95% Coverage) : Limited Fire Hazard complying with NES 518 Material. ISO OHSAS : - 9 C to +85 C : 600 V : 1.5 kv : 10 x Cable Diameter : 4 x Cable Diameter Limited Fire Hazard Siechem Multicore Specially Flexing Cables, Collectively Screened Marine Cable P x P x P x P x P x P x P x P x / / / / / / / / NES 55 C9 131

133 TABLE C10 : Multipair Cables - Collectively Screened 1.0mm Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Ship systems & equipments and weapon systems & equipments. Pairs laid up Collective Screen : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with BS : 6360 : Limited Fire Hazard Compound Test Voltage Bending Radius Flexing Fixed : Annealed Tinned Copper braid (95% Coverage) : Limited Fire Hazard complying with NES 518 Material. ISO OHSAS : - 9 C to +85 C : 600 V : 1.5 kv : 10 x Cable Diameter : 4 x Cable Diameter Limited Fire Hazard Siechem Multicore Cables, Cores Individually Screened Marine Cable P x 1.0 3P x 1.0 5P x 1.0 7P x 1.0 1P x P x 1.0 7P x / / / / / / / NES 55 C10 13

134 TABLE C11 : Multipair Cables - Individually Screened 0.35mm Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Ship systems & equipments and weapon systems & equipments. Cores laid up Individual Screen Pairs laid up : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with BS : 6360 : Limited Fire Hazard Compound : Annealed Tinned Copper braid (95% Coverage) : Limited Fire Hazard complying with NES 518 Material. Test Voltage Bending Radius Flexing Fixed ISO OHSAS : - 9 C to +85 C : 600 V : 1.5 kv : 10 x Cable Diameter : 4 x Cable Diameter Limited Fire Hazard Siechem Multicore Cables, Cores Individually Screened Marine Cable P x P x P x P x / / / / NES 55 C11 133

135 TABLE C1 : Multipair Cables - Individually Screened 1.0mm Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Ship systems & equipments and weapon systems & equipments. Cores laid up Individual Screen Pairs laid up : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with BS : 6360 : Limited Fire Hazard Compound : Annealed Tinned Copper braid (95% Coverage) : Limited Fire Hazard complying with NES 518 Material. Test Voltage Bending Radius Flexing Fixed ISO OHSAS : - 9 C to +85 C : 600 V : 1.5 kv : 10 x Cable Diameter : 4 x Cable Diameter Limited Fire Hazard Siechem Multipair Cables Individually Screened Marine Cable P x 1.0 3P x 1.0 5P x 1.0 7P x / / / / NES 55 C1 134

136 TABLE C13 : Multipair Cables - Individually and Collectively Screened 0.35mm Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Ship systems & equipments and weapon systems & equipments. Cores laid up Individual Screen Pairs laid up Collective Screen : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with BS : 6360 : Limited Fire Hazard Compound : Annealed Tinned Copper braid (95% Coverage) : Annealed Tinned Copper braid (95% Coverage) : Limited Fire Hazard complying with NES 518 Material. Test Voltage Bending Radius Flexing Fixed ISO OHSAS : - 9 C to +85 C : 600 V : 1.5 kv : 10 x Cable Diameter : 4 x Cable Diameter Limited Fire Hazard Siechem Multipair Individually & Collectively Screened Marine Cable P x 0.5 5P x 0.5 7P x 0.5 1P x P x 0.5 7P x / / / / / / NES 55 C13 135

137 TABLE C14 : Multitriple Cables - Collectively Screened 0.35mm Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Ship systems & equipments and weapon systems & equipments. Triples laid up Collective Screen : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with BS : 6360 : Limited Fire Hazard Compound Test Voltage Bending Radius Flexing Fixed : Annealed Tinned Copper braid (95% Coverage) : Limited Fire Hazard complying with NES 518 Material. ISO OHSAS : - 9 C to +85 C : 600 V : 1.5 kv : 10 x Cable Diameter : 4 x Cable Diameter Limited Fire Hazard Siechem Multitriple Collectively Screened Marine Cable T x 0.35 T x T x T x T x / /9. 8.0/ / / NES 55 C14 136

138 NES 56 Table C1: Singlecore Cables Table C: Singlecore Flexible Cables Table C3: Singlecore Cables-Low Capacitance Table C4: Singlecore and Multicore Cables,Copper Wire Braided Overall Table C5: 3 Core Flexible Cables (Large) Table C6: Multicore Cables Table C7: Multicore Cables (For DG) Table C8: Multicore Specially Flexing Cables Table C9: Multicore Specially Flexing Cables, Collectively Screened Table C10: Multicore Cables Cores Individually Screened Table C11: Multicore Cables, Cores Collectively Screened Table C1: Multicore Cables, Steel Wire Braided Table C13: Multitriple Cables Triples Individually Screened Table C14: Multitriple Cables Triples Collectively Screened 137

139 TABLE C1 : Singlecore Cables Surface ships and Submarines Ship systems & equipments and weapon systems & equipments. Used in applications where fuel and lubricating oils, hydraulic fluids and water are present. : Circular Electroplated, annealed tinned copper wire (Class ) complying with BS : 6360 : Dual extrusion (Type GP 5 / LFH) : Limited Fire Hazard complying with NES 518 Material. : - 35 C to +105 C : 440 V Test Voltage : 1.5/3 kv Bending Radius(Min) : 6 x Cable Diameter ISO OHSAS Limited Fire Hazard Siechem Singlecore Marine Cable C x 1.0 1C x 1.5 1C x.5 1C x 4.0 1C x 6.0 1C x 10 1C x 16 1C x 5 1C x 35 1C x 50 1C x 70 1C x 95 1C x 10 1C x 150 1C x 185 1C x 40 1C x 300 1C x 400 1C x 500 1C x NES 56 C1 138

140 TABLE C : Singlecore Flexible Cables Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Ship systems & equipments and weapon systems & equipments. : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with BS : 6360 : Dual extrusion (Type GP 5 / LFH) : Limited Fire Hazard complying with NES 518 Material. : - 35 C to +105 C : 440 V Test Voltage : 1.5/3 kv Bending Radius(Min) : 6 x Cable Diameter ISO OHSAS Limited Fire Hazard Siechem Singlecore Flexible Marine Cable C x 1.0 1C x 1.5 1C x.5 1C x 4.0 1C x 6.0 1C x 10 1C x 16 1C x 5 1C x 35 1C x 50 1C x 70 1C x 95 1C x 150 1C x 185 1C x 40 1C x 300 1C x NES 56 C 139

141 TABLE C3 : Singlecore Cables - Low Capacitance Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Ship systems & equipments and weapon systems & equipments. Braiding : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with BS : 6360 : Dual extrusion (Type GP 5 / LFH) : Annealed Tinned Copper braid (95% Coverage) : Limited Fire Hazard complying with NES 518 Material. : - 35 C to +105 C : 440 V Test Voltage : 6 kv Bending Radius(Min) : 6 x Cable Diameter ISO OHSAS Limited Fire Hazard Low Capacitance Siechem Singlecore Cables - Low Capacitance Marine Cable C x 1.0 1C x 1.0 1C x 1.0 1C x NES 56 C3 140

142 TABLE C4 : Single and Multicore Cables, Copper Wire Braided Overall Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Ship systems & equipments and weapon systems & equipments. Laying up Braiding : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with BS : 6360 : Dual extrusion (Type GP 5 / LFH) : Limited Fire Hazard complying with NES 518 Material. : Annealed Tinned Copper braid (95% Coverage) : - 35 C to +105 C : 440 V Test Voltage : 1.5 kv Bending Radius(Min) : 6 x Cable Diameter ISO OHSAS Limited Fire Hazard Siechem Single and Multicore Cables, Copper Wire Braided Overall Marine Cable C x 0.5 1C x 1.0 1C x 1.5 1C x.5 1C x 4.0 1C x 6.0 C x 0.5 C x 1.0 C x 1.5 C x.5 3C x 0.5 3C x 1.0 3C x 1.5 4C x C x 0.5 7C x NES 56 C4 141

143 TABLE C5 : 3 Core Flexible Cables (Large) Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Ship systems & equipments and weapon systems & equipments. Laying up : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with BS : 6360 : Dual extrusion (Type GP 5 / LFH) : Limited Fire Hazard complying with NES 518 Material. : - 35 C to +105 C : 440 V Test Voltage : 3 kv Bending Radius(Min) : 6 x Cable Diameter ISO OHSAS Limited Fire Hazard Siechem 3 Core Flexible Marine Cable C x 95 3C x C x NES 56 C5 14

144 TABLE C6 : Multicore Cables Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Ship systems & equipments and weapon systems & equipments. Laying up : Circular Electroplated, annealed tinned copper wire (Class ) complying with BS : 6360 : Dual extrusion (Type GP 5 / LFH) : Limited Fire Hazard complying with NES 518 Material. : - 35 C to +105 C : 440 V Test Voltage : 1.5/3 kv Bending Radius(Min) : 6 x Cable Diameter ISO OHSAS Limited Fire Hazard Siechem Multicore Marine Cable C x 4.0 C x 6.0 C x 10.0 C x 16 C x 5 C x 35 C x 50 C x 70 C x 95 C x 10 C x 150 3C x 4.0 3C x 6.0 3C x C x 16 3C x 5 3C x 35 3C x 50 3C x 70 3C x 95 3C x 10 3C x 150 3C x 185 3C x 40 4C x 4.0 5C x C x C x 4.0 4C x C x C x.5 44C x.5 44C x NES 56 C6 143

145 TABLE C7 : Multicore Cables (For DG) Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Ship systems & equipments and weapon systems & equipments. Laying up : Circular Electroplated, annealed tinned copper wire (Class ) complying with BS : 6360 : Dual extrusion (Type GP 5 / LFH) : Limited Fire Hazard complying with NES 518 Material. : - 35 C to +105 C : 440 V Test Voltage : 1.5/3 kv Bending Radius(Min) : 6 x Cable Diameter ISO OHSAS Limited Fire Hazard Siechem Multicore Cables (For DG) Marine Cable C x 4.0 7C x 6.0 7C x 10 7C x 16 7C x 5 7C x 35 7C x 50 7C x 70 14C x C x C x 10 14C x 16 14C x 5 18C x.5 18C x C x C x 10 18C x 16 30C x.5 30C x C x C x NES 56 C7 144

146 TABLE C8 : Multicore Specially Flexing Cables Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Ship systems & equipments and weapon systems & equipments. Binder Tape Laying up Binder Tape : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with BS : 6360 : Dual extrusion (Type GP 5 / LFH) : Polyethylene Teraphthalate : Polyethylene Teraphthalate : Limited Fire Hazard complying with NES 518 Material. : - 35 C to +105 C : 440 V Test Voltage : 1.5/3 kv Bending Radius(Min) : 6 x Cable Diameter ISO OHSAS Limited Fire Hazard Siechem Multicore Specially Flexing Marine Cable C x 1.0 C x 1.5 C x.5 C x 4.0 3C x.5 3C x 4.0 3C x 6.0 3C x 16 3C x 35 3C x 95 4C x.5 4C x 4.0 5C x.5 8C x 1.5 8C x.5 8C x C x.5 10C x C x C x.5 C x 1.5 C x.5 30C x C x.5 36C x NES 56 C8 145

147 TABLE C9 : Multicore Cables Specially Flexing Cables, Collectively Screened Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Ship systems & equipments and weapon systems & equipments. Binder Tape Laying up Binder Tape Braiding : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with BS : 6360 : Dual extrusion (Type GP 5 / LFH) : Polyethylene Teraphthalate : Polyethylene Teraphthalate : Annealed Tinned Copper braid (95% Coverage) : Limited Fire Hazard complying with NES 518 Material. : - 35 C to +105 C : 440 V Test Voltage : 1.5 kv Bending Radius(Min) : 6 x Cable Diameter ISO OHSAS Limited Fire Hazard Siechem Multicore Cables Specially Flexing Cables, Collectively Screened Marine Cables C x.5 3C x 1.0 3C x.5 4C x.5 8C x NES 56 C9 146

148 TABLE C10 : Multicore Cables Cores Individually Screened Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Ship systems & equipments and weapon systems & equipments. Braiding Binder Tape Laying up Binder Tape : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with BS : 6360 : Dual extrusion (Type GP 5 / LFH) : Annealed Tinned Copper braid (95% Coverage) : Polyethylene Teraphthalate : Polyethylene Teraphthalate : Limited Fire Hazard complying with NES 518 Material. : - 35 C to +105 C : 440 V Test Voltage : 1.5 kv Bending Radius(Min) : 6 x Cable Diameter ISO OHSAS Limited Fire Hazard Siechem Multicore Cables Cores Individually Screened Marine Cable C x C x C x C x C x NES 56 C10 147

149 TABLE C11 : Multicore Cables, Cores Collectively Screened Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Ship systems & equipments and weapon systems & equipments. Laying up Binder Tape Braiding : Circular Electroplated, annealed tinned copper wire (Class ) complying with BS : 6360 : Dual extrusion (Type GP 5 / LFH) : Polyethylene Teraphthalate : Annealed Tinned Copper braid (95% Coverage) : Limited Fire Hazard complying with NES 518 Material. : - 35 C to +105 C : 440 V Test Voltage : 1.5/3 kv Bending Radius(Min) : 6 x Cable Diameter ISO OHSAS Limited Fire Hazard Siechem Multicore Cables, Cores Collectively Screened Marine Cable C x 4.0 C x 16 3C x 10 3C x 16 3C x 5 3C x 35 3C x 50 4C x 1.0 4C x.5 4C x C x 0.5 7C x C x NES 56 C11 148

150 TABLE C1 : Multicore Cables, Steel Wire Braided Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Ship systems & equipments and weapon systems & equipments. Laying up Inner Sheath Binder Tape Braiding : Circular Electroplated, annealed tinned copper wire (Class ) complying with BS : 6360 : Dual extrusion (Type GP 5 / LFH) : Limited Fire Hazard Material : Polyethylene Teraphathalate : Galvanised Steel Wire : Limited Fire Hazard complying with NES 518 Material. : - 35 C to +105 C : 440 V Test Voltage : 3 kv Bending Radius(Min) : 6 x Cable Diameter ISO OHSAS Limited Fire Hazard Siechem Multicore Cables, Steel Wire Braided Marine Cable C x 35 7C x 70 7C x NES 56 C1 149

151 TABLE C13 : Multitriple Cables Triples Individually Screened Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Ship systems & equipments and weapon systems & equipments. Laying up Binder Tape : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with BS : 6360 : Dual extrusion (Type GP 5 / LFH) : Polyethylene Teraphthalate Individual Braid : Annealed Tinned Copper (braid 95% Coverage) Binder Tape : Polyethylene Teraphthalate : Limited Fire Hazard complying with NES 518 Material - Black. : - 35 C to +105 C : 440 V Test Voltage : 1.5 kv Bending Radius(Min) : 6 x Cable Diameter ISO OHSAS Limited Fire Hazard Siechem Multitriple Cables Triples Individually Screened Marine Cable T x 0.5 7T x NES 56 C13 150

152 TABLE C14 : Multitriple Cables Triples Collectively Screened Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Ship systems & equipments and weapon systems & equipments. Laying up Binder Tape Collective Braid : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with BS : 6360 : Dual extrusion (Type GP 5 / LFH) : Polyethylene Teraphthalate : Annealed Tinned Copper (braid 95% Coverage) : Limited Fire Hazard complying with NES 518 Material - Black. : - 35 C to +105 C : 440 V Test Voltage : 1.5 kv Bending Radius(Min) : 6 x Cable Diameter ISO OHSAS Limited Fire Hazard Siechem Multitriple Cables Triples Collectively Screened Marine Cable T x 0.5 3T x 0.5 7T x NES 56 C14 151

153 NES 57 Table C1: Singlecore Cables TableC: Twin and Three Core Cables Table C3: Multicore Cables Table C4: Twin and Multicore Cables Table C5: Multi-Paired Cables Collectively Screened Table C6: Multicore Cables Individually Screened Cores Table C7: Multi-Paired Cables Pairs Individually Screened Table C8: Multicore Cables Collectively Screened Table C9: Miniature Multicore Cables Unscreened or Individually or Collectively Screened Table C10: Miniature Pair and Triple Cables Collectively Screened Table C11: Miniature Multicore Cables Individually and Collectively Screened Cores 15

154 TABLE C1 : Singlecore Cables Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Ship systems & equipments and weapon systems & equipments. Protective Tape : Circular Electroplated, annealed tinned copper wire (Class ) complying with BS : 6360 : Silicone Rubber (Type E / Type T) : Glass Mica Tape : Limited Fire Hazard complying with NES 518 Material - Black. : - 30 C to +105 C : 440 V Test Voltage : 1.5/3.5 kv Bending Radius(Min) : 6 x Cable Diameter ISO OHSAS Limited Fire Hazard Siechem Singlecore Marine Cable C x 1.0 1C x 1.5 1C x.5 1C x 4.0 1C x 6.0 1C x 10 1C x 16 1C x 5 1C x 35 1C x 50 1C x 70 1C x 95 1C x 10 1C x 150 1C x 185 1C x 40 1C x 300 1C x 400 1C x 500 1C x NES 57 C1 153

155 TABLE C : Twin and Three Core Cables Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Ship systems & equipments and weapon systems & equipments. Protective Tape Laying up : Circular Electroplated, annealed tinned copper wire (Class ) complying with BS : 6360 : Silicone Rubber (Type E / Type T) : Glass Mica Tape : Limited Fire Hazard complying with NES 518 Material - Black. : - 30 C to +105 C : 440 V Test Voltage : 1.5/3.5 kv Bending Radius(Min) : 6 x Cable Diameter ISO OHSAS Limited Fire Hazard Siechem Twin and Three Core Marine Cable C x 1.0 C x 1.5 C x.5 C x 4.0 C x 6.0 C x 10 C x 16 3C x 1.0 3C x 1.5 3C x.5 3C x 4.0 3C x 6.0 3C x 10 3C x 16 C x 5 C x 35 C x 50 C x 70 C x 95 3C x 5 3C x 35 3C x 50 3C x 70 3C x C x C x C x C x NES 57 C 154

156 TABLE C3 : Multicore Cables Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Ship systems & equipments and weapon systems & equipments. Protective Tape Laying up : Circular Electroplated, annealed tinned copper wire (Class ) complying with BS : 6360 : Silicone Rubber (Type E / Type T) : Glass Mica Tape : Limited Fire Hazard complying with NES 518 Material - Black. : - 30 C to +105 C : 440 V Test Voltage : 1.5/3.5 kv Bending Radius(Min) : 6 x Cable Diameter ISO OHSAS Limited Fire Hazard Siechem Multicore Marine Cable C x 16 14C x C x C x 10 14C x 16 18C x C x 10 18C x 16 30C x C x.5 30C x C x C x 10 7C x 5 7C x 35 7C x 50 7C x 70 14C x 5 14C x NES 57 C3 155

157 TABLE C4 : Twin and Multicore Cables Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Ship systems & equipments and weapon systems & equipments. Protective Tape Laying up : Circular Electroplated, annealed tinned copper wire (Class ) complying with BS : 6360 : Silicone Rubber (Type E) : Glass Mica Tape : Limited Fire Hazard complying with NES 518 Material - Black. : - 30 C to +105 C : 440 V Test Voltage : 1.5 kv Bending Radius(Min) : 6 x Cable Diameter ISO OHSAS Limited Fire Hazard Siechem Twin and Multicore Marine Cable C x 1.0 3C x 1.0 4C x 1.0 5C x 1.0 7C x C x C x C x 1.0 4C x C x C x C x 1.0 C x.5 3C x.5 4C x.5 5C x.5 7C x.5 10C x.5 14C x.5 18C x.5 4C x.5 30C x.5 36C x.5 44C x.5 C x 4.0 3C x 4.0 4C x 4.0 5C x 4.0 7C x C x C x C x 4.0 4C x

158 C x C x NES 57 C4 157

159 TABLE C5 : Multi-Paired Cables Collectively Screened Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Ship systems & equipments and weapon systems & equipments. Protective Tape Laying up Braiding : Circular Electroplated, annealed tinned copper wire (Class ) complying with BS : 6360 : Silicone Rubber (Type E) : Glass Mica Tape : Annealed Tinned Copper (braid 95% Coverage) : Limited Fire Hazard complying with NES 518 Material - Black. : - 30 C to +105 C : 440 V Test Voltage : 1.5 kv Bending Radius(Min) : 6 x Cable Diameter ISO OHSAS Limited Fire Hazard Siechem Multi-Paired Cables Collectively Screened Marine Cable P x 1.0 P x 1.0 3P x 1.0 4P x 1.0 7P x P x P x P x NES 57 C5 158

160 TABLE C6 : Multicore Cables Individually Screened Cores Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Ship systems & equipments and weapon systems & equipments. : Circular Electroplated, annealed tinned copper wire (Class ) complying with BS : 6360 : Silicone Rubber (Type E) Protective Tape : Glass Mica Tape Individual Braid : Annealed Tinned Copper (braid 95% Coverage) Laying up Binder Tape : Polyethylene Teraphthalate : Limited Fire Hazard complying with NES 518 Material - Black. : - 30 C to +105 C : 440 V Test Voltage : 1.5 kv Bending Radius(Min) : 6 x Cable Diameter ISO OHSAS Limited Fire Hazard Siechem Multicore Cables Individually Screened Cores Marine Cable C x 1.0 5C x 1.0 7C x C x C x NES 57 C6 159

161 TABLE C7 : Multi-Paired Cables Pairs Individually Screened Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Ship systems & equipments and weapon systems & equipments. : Circular Electroplated, annealed tinned copper wire (Class ) complying with BS : 6360 : Silicone Rubber (Type E) Protective Tape : Glass Mica Tape Individual Braid : Annealed Tinned Copper (braid 95% Coverage) Laying up Binder Tape : Polyethylene Teraphthalate : Limited Fire Hazard complying with NES 518 Material - Black. : - 30 C to +105 C : 440 V Test Voltage : 1.5 kv Bending Radius(Min) : 6 x Cable Diameter ISO OHSAS Limited Fire Hazard Siechem Multi-Paired Cables Pairs Individually Screened Marine Cable P x 1.0 3P x 1.0 4P x 1.0 7P x NES 57 C7 160

162 TABLE C8 : Multicore Cables Collectively Screened Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Ship systems & equipments and weapon systems & equipments. : Circular Electroplated, annealed tinned copper wire (Class ) complying with BS : 6360 : Silicone Rubber (Type E) Protective Tape : Glass Mica Tape Laying up Collective Braid : Annealed Tinned Copper (braid 95% Coverage) Binder Tape : Polyethylene Teraphthalate : Limited Fire Hazard complying with NES 518 Material - Black. : - 30 C to +105 C : 440 V Test Voltage : 1.5 kv Bending Radius(Min) : 6 x Cable Diameter ISO OHSAS Limited Fire Hazard Siechem Multicore Cables Collectively Screened Marine Cable C x 1.0 8C x 1.0 1C x C x 1.0 4C x.5 C x 4.0 6C x 1.0 8C x.5 C x NES 57 C8 161

163 TABLE C9 : Miniature Multicore Cables Unscreened or Individually or Collectively Screened Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Ship systems & equipments and weapon systems & equipments. : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with BS : 6360 : Silicone Rubber (Type E / Type T) Protective Tape : Glass Mica Tape Individual Braid : Annealed Tinned Copper (braid 95% Coverage) Laying up Collective Braid : Annealed Tinned Copper (braid 95% Coverage) Binder Tape : Polyethylene Teraphthalate : Limited Fire Hazard complying with NES 518 Material - Black. : - 30 C to +105 C : 440 V Test Voltage : 1.5 kv Bending Radius(Min) : 6 x Cable Diameter ISO OHSAS Limited Fire Hazard Siechem Miniature Multicore Cables Unscreened or Individually or Collectively Screened Marine Cable C x C x C x C x C x C x C x C x C x C x C x C x C x C x C x C x C x C x C x C x C x C x C x C x NES 57 C9 16

164 TABLE C10 : Miniature Pair and Triple Cables Collectively Screened Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Ship systems & equipments and weapon systems & equipments. : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with BS : 6360 : Silicone Rubber (Type E / Type T) Protective Tape : Glass Mica Tape Pairs /Triples laid up Collective Braid : Annealed Tinned Copper (braid 95% Coverage) Binder Tape : Polyethylene Teraphthalate : Limited Fire Hazard complying with NES 518 Material - Black. : - 30 C to +105 C : 440 V Test Voltage : 1.5 kv Bending Radius(Min) : 6 x Cable Diameter ISO OHSAS Limited Fire Hazard Siechem Miniature Pair & Triple Cables Collectively Screened Marine Cable P x 0.35 P x P x P x P x P x T x 0.35 T x T x T x T x NES 57 C10 163

165 TABLE C11 : Miniature Multicore Cables Individually and Collectively Screened Cores Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Ship systems & equipments and weapon systems & equipments. Limited Fire Hazard : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with BS : 6360 : Silicone Rubber (Type E / Type T) Protective Tape : Glass Mica Tape Individual Braid : Annealed Tinned Copper (braid 95% Coverage) Laying up Collective Braid : Annealed Tinned Copper (braid 95% Coverage) Binder Tape : Polyethylene Teraphthalate : Limited Fire Hazard complying with NES 518 Material - Black. Siechem Miniature Multicore Cables Individually & Collectively Screened Cores Marine Cable : - 30 C to +105 C : 440 V Test Voltage : 1.5 kv Bending Radius(Min) : 6 x Cable Diameter ISO OHSAS C x C x C x C x NES 57 C11 164

166 Multicore Armoured and Sheathed Type P Control Cable 600V or 0.6/1kV Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Ship systems & equipments and weapon systems & equipments. Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact Super-flexible at 4/0 AWG and larger Meets IEEE standards for 600V / IEC standards for 0.6/1kV Jacket Armour Siechem Multicore Armoured / Sheathed Type P Control Marine Cable : Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used over the conductor. : Cross-inked polyolefin (XLPO), meeting IEEE 1580 (001). : Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in IEEE-1580 (001). : Braided bronze in accordance with IEEE 1580 (001). : Flame-retardant Arctic Neoprene applied over the armor, complying with Type N Neoprene as required in IEEE 1580 (001). Test Voltage ISO OHSAS : - 30 C to +15 C : 600 V : 0.6 kv Number of Cores AWG - mm C x 1 AWG mm 3C x 1 AWG mm 4C x 1 AWG mm 5C x 1 AWG mm 6C x 1 AWG mm 7C x 1 AWG mm 8C x 1 AWG mm 10C x 1 AWG mm 1C x 1 AWG mm 16C x 1 AWG mm 0C x 1 AWG mm 4C x 1 AWG mm 30C x 1 AWG mm 37C x 1 AWG mm 44C x 1 AWG mm 60C x 1 AWG mm 91C x 1 AWG mm C x 10 AWG mm 3C x 10 AWG mm 4C x 10 AWG mm 5C x 10 AWG mm 6C x 10 AWG mm 7C x 10 AWG mm 8C x 10 AWG mm 10C x 10 AWG mm

167 A brief description of Cross-Linking, Product realiability, advantages and testing of Siechem Marine cables and accessories. Polymer Cross-Linking Information Siechem Marine Power, Control & Data Transmission Cables & Sheath is energy electron beam irradiation cross linked from in house state of the art irradiation centre with prestigious AERB, (Govt. of India) Mumbai approval. The and Sheath materials are made of polyolefin co-polymer. Polyolefin consists of many random molecular chains, with no particular orientation, and no chemical bonds existing between chains before cross linking. After irradiation cross linking ( as shown in figure-1) the free & random molecular chains are cross linked as shown in the figure- A. DURING IRRADIATION ELECTRON RADIATION H.V. Generator ELECTRON RADIATION AcceleratorChannel Deflecting Magnet B. AFTER IRRADIATION Cable CROSSLINK BONDS Figure 1 The State of Polymer Chain before and after cross linking Figure Layout of Electron beam Figure Two random polymeric molecules during and after irradiation cross linking Electron Beam Cross Linked Marine cables have higher Electrical, Mechanical, Thermal & Weathering properties. EBXL Siechem Marine cables have following special features. 1. Do not melt or flow even at very high temperatures.. High resistance against UV, Ozone & Hydrolysis. 3. Good flexibility, easy to strip 4. Improved abrasion/cut through 5. Better crush resistance 6. Solder iron resistance 7. Better over load characteristics 8. Resistance to stress cracking 9. Improved fluid, chemical & oil resistance 10.Slightly better flame resistance 11. Negligible change in thermal stability & electrical property 1. Improved fire resistance performance 13. Higher short circuit capacity 14. Improved high temperature mechanicals 15. High Degree of Cross-Linking and homogenity 16. Polymer degradation due to high temperature as EB Cross-Linking occurs at room temperature 17. oxidative degradation in polymers as observed in chemical cross-linking and so on. 166

168 During the irradiation process, high energy electrons are bombard over the insulation system. Figure illustrates two random polymeric molecules being subject to irradiation. The energy of irradiation ejects a hydrogen atom which then removes a neighboring hydrogen atom, forming molecular hydrogen gas (H ). The vacant sites on the adjacent polymer chain then combine to create a cross-link bond. For most plastic materials, equivalent properties may be obtained by the use of either continuous vulcanizing or moisture cross linking, but irradiation may have the following advantage in addition to what is discussed above: 1. Irradiation has no lower limit on physical size, smaller conductor sizes, and thin insulation walls may be provided.. Irradiation does not use high temperature or pressure. Separator tapes are not required to prevent thin wall insulations from being forced into the conductor strand surface. 3. Irradiation offers the insulation compounder design freedom. Compound additives may be chosen without regard to their reaction to high temperatures and to moisture. Fire Retardant Fire retardant cables are designed for use in fire situations where the spread of flames along a cable route need to be retarded. Due to relative low cost, fire retardant cables are widely used as fire survival cables. matter the cables are installed in single wire or in bundles, during a fire, the flame spread will be retarded and the fire will be confirmed to a small area, thus reducing the fire hazard due to fire propagation. Flame Retardant Siechem EBXL XLPO Cable offers reliable fire retardant or slow the progress of fire in extreme fire conditions and flame along the cable. This is possible because of specially formulated XLPO jacketing materials that do not readily burn and will tend to self-extinguish. Low Smoke & Halogen Free & Fire retardant ( LSZH ) Siechem Cable combines LSZH-rated insulation and jackets with rugged performance. Low smoke means easier visibility for evacuation and reduced respiratory damage due to smoke, while the zero-halogen material reduces toxicity to almost to negligible level from halogenated gases. Siechem Low-smoke Zero-halogen cables feature tinned copper conductors that resist corrosion and stranded conductors for installation flexibility. The LSZH cable is available in multi conductor / multi pair configurations, shielded or unshielded, foil shielded for EMI protection and improved signal integrity, as well as color-coding. The LSZH cables are suited to confined-space applications to reduce harm, save lives, and reduce damage to electronic components. Thanks to halogen free cables the formation of extremely aggressive corrosive and toxic gasses are prevented. Low Smoke Fume (LSF) The low halogen content and low corrosivity of low smoke fume cables lies somewhat in between fire retardant cables and LSZH cables. Low Halogen cable also contains halogen but the content is much less than PVC cables. LSF cable is designed to reduce the spread of fire, toxic gases and smoke during fire. The LSF cable is usually manufactured from flame retardant PVC blended with HCL additive and smoke absorbent. These materials help improve the fire performance of the LSF cables. Fire Resistant Cables are designed to maintain circuit integrity of those vital emergency services during the fire. The individual conductors are wrapped with a layer of fire resisting mica / glass tape which prevents phase to phase and phase to earth contact even after the insulation has been burnt away. The fire resistant cables exhibit same performance even under fire with water spray or mechanical shock situation. 167

169 Fire Performance Class The main concern for the cable in its fire survival properties are its flame spread, smoke characterization and gas toxicity. In American fire standard, the concern lies more on the first two and it differs from the European standard which concerns all these aspects. In USA, it is believed that the fire hazard is mainly due to CO toxic gas emitted and the heat release during the conversion of CO to CO during the fire. Therefore, to control the heat release is the most important concern for reducing the fire hazard. However, in European countries, halogen content, the corrosively of the gases, the smoke density and the toxicity of the gas are equally important factors affecting the safety and survival of human during a fire. Temperature Index as per IEC 6016/VDE 0304 part 1 The temperature index describes the long-term performance of insulating materials. The temperature index defines the ageing temperature (in C), at which the insulating material still has an absolute elongation at break of 50 % after 00 hours. A 10 C higher temperature index results in approximately doubling the life expectation of the insulating materials. In order to determine the long term temperature stability of an insulating material the different ageing times corresponding to different temperatures are measured and recorded in a so called Arrhenius- Diagram (ordinate-axis : log time, abscissa axis: the reciprocal absolute temperature). A straight line is drawn to connect the various recorded points. By prolonging the straight line until it intersects the 00 hour axis it is possible to determine the lifetime or the temperature index. Hours 0 Temperature C The European Electrical Committee categorized the fire performance of the cables into three classes, namely IEC6033-1, IEC6033- & IEC IEC and IEC are used to assess the flame propagation characteristics of a single wire. IEC is used to assess the flame propagation chacteristics of bundled cables. Comparatively speaking, IEC for bundled cables is more demanding than IEC for single wires. IEC / BS EN ; 009 ( Flame Test on Single Vertical Insulated Wires/Cables ) This test details a method of test for the assessment of the flame propagation characteristics of a single wire or cable. In this test, a 60cm cable sample is fixed 0 vertically inside a metallic box and a 175 mm long flame is applied at 45 C from a gas burner placed at 450 mm from the top at the upper portion. The specimen is deemed to have passed this test, of after burning has ceased, the charred or affected position does not reach within 50mm of the lower edge of the top clamp which is equivalent to 45 mm above the point of flame application. The test method is not suitable for the testing of some small wires due to the melting of the conductors during the time of application of the flame. 168

170 IEC ( Flame Test on Bunched Wires/Cables ) Vertical Flame Test IEC6033-3C describes a method of type approval testing to define the ability of bunched cables to resist fire propagation. In this test, a cable specimen, consisting of number of 3.5m lengths of cables are fixed to a vertical ladder tray where they are applied with a flame from a gas burner for a specified times under controlled air flow. Four categories (A, B, C & D) are defined and distinguished by test duration and the volume of non metallic material of the sample under test. The cable specimen is deemed to have met the requirements of the standard if, after burning has ceased, the extent of charred or affected portion does not reach a height exceeding.5m above the bottom edge of the burner. UL Fire standard If a cable can pass a specified UL fire standard, an UL performance verification mark can be applied onto the cable jacket, illustrating both the UL class and the number. There are four primary fire testing standards as follows: CMP (Plenum Flame Test / Steiner Tunnel Test) Plenum rated cables meet the NFPA-6 standard (formerly known as UL 910) which provides the most stringent requirement of all the tests. Cable samples on a horizontal tray in a tunnel type of chamber are burned at 87.9KW ( BTU / Hr) for 0 minutes. To qualify for a plenum rating, the cables must have the flame spread of less than 5 feet or 1.5 meters, with a smoke density during the test of (a) 0.5 peak ; and (b) 0.15 maximum average. The CMP cable is usually installed in air ventilation duct and air return widely used in Canada and USA. The fire retardancy properties of CMP cable is much better than LSZH cable complying with IEC

171 CMR (Riser Flame Test) Riser rated cables meets UL Cable samples on a vertical shaft are burned at 154.5KW (57500 BTU / Hr) for 30 minutes. To qualify for a riser rating, the cables must have the flame spread of less than 1 feet beyond the ignition point. This test does not look at the smoke density or toxicity. Riser cable is suitable for vertical shafts not defined as an environmental air plenum. CM (Vertical Tray Flame Test) General purpose cables meets UL Cables samples on a feet vertical tray are burned at 0KW (70,000 BTU / Hr) for 0 minutes. The cable is deemed to pass the test if the flame spread will not extend for that the number of testing samples is different. This test does not look at the smoke density or toxicity. The CMG cables are usually used in runs penetrating single floor. This cable cannot be installed in vertical pathways. CMG (Vertical Tray Flame Test) This general purpose cables also meets UL CM and CMG are similar, both recognized in Canada and USA. This test does not look at the smoke density or toxicity. The CMG cables are usually used in runs penetrating single floor. This cable cannot be installed in vertical pathways. The restricted cable meets UL 1581, Limited-use. The test consists of 5 feet long ventilated tunnel. The cable is placed on a ladder inside the tunnel and the flame of 30,000 BTU / Hr is applied to the cable 15 seconds and on seconds off five times for a total exposure to the flame of 1 minute and 15 seconds. To qualify for this test, after the test flame is removed, the cable can flame for not more than 60 seconds and the charred portion will not exceed by 5%. UL 1581, VW-1 is similar to IEC , except for the difference in the time for flame applied. This test does not look at the smoke density or toxicity. The CMG cable is suitable for use in dwellings and for use in raceway. This cable cannot be installed in bundles and must be protected in metal conduit. This type of cable is the minimum requirement in commercial installations. IEC /BS645-1 Emission Of Halogens This specifies a test for determination of the amount of halogen acid gas, other than the hydrofluoric acid, evolved during combustion of compound based on halogenated polymers and compounds containing halogenated additives taken from cable constructions. Halogen includes Fluorine, Chlorine, Bromine, Iodine and Astatine. All these elements are toxic by its nature. The material is considered to be halogen free if no green to blue-green flame discolouration occurs. The chlorine and the bromine would cause such a discolouration, however the existence of fluorine cannot be proven like that. Halogen Test 170

172 0 In this test, when the burner is heated to 800 C, 1g sample is placed inside and the HCl is absorbed into water inside the chamber fed with air flow. The water is then tested with its acidity. If the hydrochloric acid yield is less than 5%, the cable is categorized as LSZH. If the hydrochloric acid yield lies between 5% to 15%, the cable is categorized as LSF. IEC cannot be used for measuring the exact HCl yield if it is less than 5% and thus cannot tell if the cable is halogen free or not. To determine if the cable is halogen free, IEC should be used. IEC Acidity This test specifies a method for the determination of degree of acidity of gases evolved during combustion of cables taken from the cable sample by measuring its ph and conductivity. The specimen is deemed to pass this test if the ph value is not less than 4.3 when related to 1 litre of water and conductivity is less than 10 s/min. When the HCl yield lies between mg/g and 5mg/g, a cable specimen can pass IEC but its ph value may be less than 4.3 and therefore will not pass the IEC test. ʮ IEC &/ASTM E66 Smoke Density Acidity Test This specifies a test for determination of smoke density. The 3 metre cube test measures the generation of smoke from electric cables during fire. A light beam emitted from a window is projected across the enclosure to a photo cell connected to a recorder at the opposite window. The recorder is adjusted to register from 0% for complete obscuration to 100% luminous transmission. A 1 metre cable sample is placed in the centre of the enclosure and is applied with a fire. The minimum light transmission is recorded. The result is expressed as percentage of light transmitted. The specimen is deemed to pass this test ( IEC &) if the value is greater than 60%. The higher the light transmittance, the less smoke emitted during a fire. 95% Visibility Visibility (For example : EBXL - XLPO) (For example : PVC) 171

173 Melts Reasonably Wires & Cables Table 1: Comparative Study of EBXL ZHLS+HR+FR (XLPO), Power Cables Vs Others Specification for Electron Beamed Single core, Unsheathed, Multi strand, Copper, Flexible Wire Cables and Comparison between EBXL, Power Cable Vs Others Sl. Test Details Unit Conventional PVC Cables as per IS:694/IS: C XLPE (Chemical Curing) 90 C EBXL - XLPE 0 10 C Specially Formulated EBXL - ZHLS + FR 0 (XLPO) 10 C For Marine Cables A) 1.0 Material Annealed Plain EC grade flexible copper Annealed Plain EC grade flexible copper Annealed Plain EC grade flexible copper Annealed Plain EC grade flexible copper.0. of wires/dia of wire /mm As per IS:8130/84 or IEC 608 : Class 5 As per IS:8130/84 or IEC 608 : Class 5 As per IS:8130/84 or IEC 608 : Class 5 As per IS:8130/84 or IEC 608 : Class Diameter mm As per IS:8130/84 or IEC 608 : Class 5 As per IS:8130/84 or IEC 608 : Class 5 As per IS:8130/84 or IEC 608 : Class 5 As per IS:8130/84 or IEC 608 : Class DC Resistance at 0 C ohm/km As per IS:8130/84 or IEC 608 : Class 5 As per IS:8130/84 or IEC 608 : Class 5 As per IS:8130/84 or IEC 608 : Class 5 As per IS:8130/84 or IEC 608 : Class 5 B) 1.0 Material PVC Type A Cross - linked Polyethylene minal Thickness Overall diameter of cable mm mm thickness as per IS:694 table for insulation dia + ( X t) t=thickness of insulation as per IS : 694 Upto 33% thickness less than that of IS:694 table for insulation dia + ( X t) t=thickness of insulation as per IS : 694 Electron Beam Cross - linked Polyethylene Upto 33% thickness less than that of IS:694 table for insulation dia + ( X t) t=thickness of insulation as per IS : 694 Electron Beam cross - linked Polyolefin Upto 33% thickness less than that of IS:694 table for insulation dia + ( X t) t=thickness of i nsulation as per IS : 694 C) General 1.0 Continuous operating Temp.0 Short circuit Temperature 0 C & C & Soldering iron Resistance Melts and emit dark smoke Melts Reasonably Resistant & shall not melt Resistant & shall not melt 4.0 Ozone resistance at complete cable C % h % NA NA NA Temperature at 40 ± Relative Humidity 55 ± 5 Duration 7 Ozone concentration (00 ± 50) x 10 6 Absence of cracks 5.0 Weathering / UV Resistance h C % W/m² min NA NA NA Duration 70 Black Standard Temp. 63 C Relative Humidity 65 Min. power at wavelength 300nm to 400nm is 60 ± Duration spraying / drying is 18/10 Absence of cracks. 17

174 D) Mechanical Properties Sl. Test Details Unit Conventional PVC Cables as per IS:694/IS: C XLPE (Chemical Curing) 90 C EBXL - XLPE 0 10 C Specially Formulated EBXL - ZHLS + FR 0 (XLPO) 10 C For Marine Cables Test Method IS : Test Method IS : Test Method IS : Test Method IS : Tensile Strength Min. N/Sq.mm Elongation at break Min. % After ageing in air oven : 3.1 Test Temperature C Duration 168 hrs (7 days) 168 hrs (7 days) 168 hrs (7 days) 40 hrs (10 days) Variation in Tensile strength Max. Variation in Elongation at break Cold bend / impact test : % ±0 ± 5 ± 5 ± 15 % ±0 ± 5 ± 5 ±15 % < 4.0% 4.0% % < 0.5% 4.1 Test Temp. C Duration hrs 1 hr 1 hr 1 hr 1 hr 4.3 Result Cracks Cracks Cracks Cracks 1.0 Loss of mass : E) Thermal Properties 1.1 Temperature C 80 ± 80 ± ± 1. Duration Days Results Max. mg/sq. cm Hot Deformation at 100 ± C for 1 Hr depth of indentation Max. % 50% 50% 15% 5%.1 Heat Shock test. Test Temp C Duration hrs 1 hr 1 hr 1 hr 1 hr.4 Result Visual/kV Cracks Cracks cracks cracks Withstand 6kV 5 mins 173

175 F) Electrical Properties Sl. Test Details Unit Conventional PVC Cables as per IS:694/IS: C XLPE (Chemical Curing) 90 C EBXL - XLPE 0 10 C Specially Formulated EBXL - ZHLS + FR 0 (XLPO) 10 C For Marine Cables resistance: Volume resistivity at 7 C Volume resistivity at 10 C resistance at 7 C resistance at 90 C Ohm cm 1 X X X >1 X Ohm cm Fails Fails 1 X X 10 1 Mohm km 36.7 >500 >500 >500 Mohm km at 90 C (fails) at 90 C (fails) > 50 > 50 High Voltage Test 1.0 after ageing of complete cable : 1.1 Ageing temp. C Duration 168 hrs ( 7 days ) 168 hrs ( 7 days ) 168 hrs ( 7 days ) 168 hrs ( 7 days ).0 Test voltage kv 3 kv for 5 minutes 3 kv for 5 minutes 6 kv for 5 minutes 6 kv for 5 minutes 3.0 Withstand test at room temperature 4.0 Break down voltage Min. 3kV for 5 min 3kV for 5 min 6 kv for 5 min 6 kv for 5 min kv <10 < Spark test kv As per IS:694 test voltage As per IS:694 test voltage H) Fire Retardent Properities 5% higher than IS:694 test voltage 5% higher than IS:694 test voltage 1.0 Smoke density (ASTM D 843)Max..0 Toxicity index (NES 713) 3.0 Oxygen Index 4.0 Acid gas emmission (IEC 754 P-1) 5.0 Temperature index (ASTM D 863)Min. Sweedish Chimney 6.0 test 6.1 Flammability as per IEC Length of unaffected portion from lower edge of top clamp % >80 NA NA 10 % >5 >10 >10 <5 % 9 >9 >9 >30 % >5 (fails) NA Nil Nil C 160 (fails) Pass NA Excellent Excellent < >350 mm <60 <60 <0 <0 174

176 I) Field Test Sl. Test Details Unit Conventional PVC Cables as per IS:694/IS: C XLPE (Chemical Curing) 90 C EBXL - XLPE 0 10 C Specially Formulated EBXL - ZHLS + FR 0 (XLPO) 10 C For Marine Cables 1.0 Soldering iron test: Hot Soldering iron shall be kept on the wire for minimum 1 minute The insulation melts or drip with dark smoke emmission Melts Reasonably The insulation shall not melt or drip and no smoke shall be emmitted The insulation shall not melt or drip and no smoke shall be emmitted TABLE COMPARATIVE STUDY OF EBXL - HFFR(XLPO), POWER CABLE Vs OTHERS ELECTRICAL PROPERTIES Property General PVC 70 C FRLS PVC 70 C HFFR 90 C XLPE (Chemical Curing) 90 C EBXL - XLPE 0 10 C Specially Formulated EBXL - ZHLS + FR 0 (XLPO) 10 C For Marine Cables resistance Min. at room temp. 1 x Ω-Cm 10 1 x 10 Ω-Cm 10 1 x 10 Ω-Cm 14 1 x 10 Ω-Cm 15 1 x 10 Ω-Cm 15 1 x 10 Ω-Cm At operating temp. 9 1 x 10 Ω-Cm 9 1 x 10 Ω-Cm 9 1 x 10 Ω-Cm 1 1 x 10 Ω-Cm 1 1 x 10 Ω-Cm 1 1 x 10 Ω-Cm High voltage water immersion test after 6 hrs Time Period 6 kv 6 kv 6 kv 6 kv 6 kv 6 kv 5 minutes 5 minutes 5 minutes 5 minutes 5 minutes 5 minutes Dielectric constant 5 to 6 5 to 6 3 to C cables are impressive and show very high electrical integrity than PVC, FRLS, HFFR & XLPE 90 C Tensile strength Min. 1.5 N/mm 1.5 N/mm 10.0 N/mm 1.5 N/mm 15.0 N/mm N/mm Elongation at break Min. 150% 150% >150% 00% 400% 150% - 500% Cold bend / impact test at Wind ability / bending radius -15 C -15 C -40 C - 15 C -15 C - 45 C 1 x cable dia. 1 x cable dia 9 x cable dia. 1 x cable dia. 1 x cable dia. 4 x cable dia. Density 1.45 g/cc 1.55 g/cc 1.4 g/cc 1.0 g/cc 1.0 g/cc 1.4 g/cc Cable diameter/ Weight MECHANICAL PROPERTIES More/Bulky More /Bulky More/Bulky Sleek & light weight Sleek & light weight Sleek & light weight Mechanical properties of EBXL 10 C cables are tougher & stronger than PVC, FRLS, HFFR &XLPE -90 C. 175

177 THERMAL PROPERTIES Property General PVC 70 C FRLS PVC 70 C HFFR 90 C XLPE (Chemical Curing) 90 C EBXL - XLPE 10 C Specially Formulated EBXL - ZHLS + FR 0 (XLPO) 10 C For Marine Cables Heat ageing at 80 C for 7 days 80 C for 7 days 80 C for 7 days 135 C for 7 days 158 C for 7 days 158 C for 7 days Variation in Tensile strength & elongation at break after ageing. ±0% ±0% ±0% ±5% ±15% ±15% Hot deformation Max 50% 50% 50% 50% <5% <5% Heat shock test Result At 150 C for 1 hr shall not crack at 00 C for 1 hr insulation cracks At 150 C for 1 hr shall not crack at 00 C for 1 hr insulation cracks At 150 C for 1 hr shall not crack at 00 C for 1 hr insulation cracks At 150 C for 1 hr shall not crack at 00 C for 1 hr insulation cracks At 40 C for 3 hrs shall not crack At 40 C for 3 hrs shall not crack Shrinkage Max. 4% 4% 4% 4% % 0.50% Operating temp. 7 0 C 70 C -40 C to 90 C 90 C -15 C to 10 C -45 C to 10 C & 150 C Short circuit temp. 160 C 160 C 160 C 50 C 80 C & 300 C 80 C & 300 Soldering iron resistance melts and emmits smoke melts and emmits smoke melts Melts Reasonably Resistant Resistant Thermal properties of EBXL 10 C cables are superior and conventional PVC, FRLS, HFFR & XLPE-90 C stand no comparison. FIRE PROPERTIES Smoke density max. > 80 % 60% 0% NA <10% <10% Toxicity Index High High <5 >10 <4 <4 Acid gas Emmission Max. >5% 0% Nil NA Nil Nil Flammability Melt and Drip Melt and drip Melt and drip Melt and Drip Do not melt or drip Do not melt or drip Flame propagation High High Moderate High High Very low Fire properties of EBXL XLPO cables stands tall compared with the PVC, FRLS, HFFR & XLPE cables. From the above comparison it is evident that in every respect Electron Beam Cured Zero Halogen Polyolefin Cables shows better performance compared to PVC based cables. Hence it is proposed to go in for new generation high technology, indigenously manufactured EBXL wires and cables. The details given above are for guidance only and actual results may vary marginally from different sources. 176

178 Formula for the Calculated Voltage drop in mv/a/m : e cal = e* = (3-5)% of Voltage applied. permissible voltage drop (e*) x 1000 current (l) x length (I) Voltage Drop for 1 Phase Size Voltage Current Rating Mtrs Volt. Drop Voltage Drop for 3 Phase Size Voltage Current Rating Mtrs Volt. Drop

179 Maximum A.C. Continuous Current - Offshore size (mm ) In free air or on a perforated cable tray Clipped to a nonmetallic surface Single-Core Cable Multicore Cable Single-Core Cable Multicore Cable Two cables single - phase or three or four cables 3-phase spaced (A) Three cables 3 - phase, flat and touching or trefoil (A) One -core cable, single-phase (A) One 3- or 4- core cable, 3-phase ( A ) Two cables, single-phase ( A ) 3 or 4 cable, 3-phase ( A ) One -core cable, single-phase (A) One 3- or core cable, 3-phase ( A ) Rating Factor For Ambient Temperature 0 Ambient temperature ( C) Rating Factor

180 Standard conditions for current rating The tabled values for the current rating were calculated according to IEC 87 for the following standard conditions: Continuous operation single circuit for 3--phase current, single conductor for 1--phase current 30 C ambient temperature and sufficiently large and ventilated spaces, whose ambient temperature is not appreciably increased by the heat coming from the cables. 10 C conductor temperature. Frequency up to 00 Hz. Installation in air, unrestricted heat dissipation, means that the following installation conditions are observed: Distance of the cables from the wall, from the floor, from the ceiling greater than cable diameter. Distance between two adjacent power circuits greater than x cable diameter. Vertical distance between power circuits laid one upon another for individual cables greater than x cable diameter and for layers of cables > 00 mm Perforated tray with a perforation > 30 % of the total surface. Open trays are continuous supports with vertical sides, but without cover. A possible perforation accounts for < 30% of the total surface. Closed ducts are entirely closed. Pipes belong to this category also. The max. filling degree is 70%. 0 De rating Factors for Deviating Ambient Temperature (Basis 30 C) Ambient 0 Temp. C Reduction Factor RF1 0 Current Rating C Reduction Factors for Different Temperature Temp. 0 C Reduction Factor RF Maximum permitted typical conductor temperature for various insulation materials according to IEC 6016 (0000 h/50 % Elongation at break) Material PVC,FRLS XLPE & EPR(Chemical cured) 0 Temperature C Siechem EBXL - XLPO 10 Siechem EBXL - XLPE

181 Lifetime Expectation If cross linked wires are used at higher temperatures than indicated by the temperature index of IEC 6016, the lifetime is reduced accordingly, conversely, the lifetime will increase at lower temperatures. Siechem EBXL cable 15 for example has a life span of 0'000 h at a conductor temperature of +10 C, which is approx..5 years. If it is used at another temperature, lifetime expectations are as follows: 6 10 Lifetime Expectation 5 10 Lifetime in Hours Temperature in Degrees 0 Current Rating 10 C Ambient Temperature 30 0 C Free Air Construction Sq.mm 1x 0 On Surfaces without Opposite Contact 1x 0 On Surfaces with Opposite Contact In Conduict, Duct Ambient Temperature 90 C Free Air Construction Sq.mm 1x 0 On Surfaces without Opposite Contact 1x 0 On Surfaces with Opposite Contact In Conduict, Duct Ambient Temperature 60 C Construction Sq.mm 1x 0 Free Air On Surfaces without Opposite Contact 1x 0 On Surfaces with Opposite Contact In Conduict, Duct

182 Installation Method Connecting lead in free air or perforated tray Number of simultaneous loaded conductors on 1x 0 1x 0 each tray Reduction Factor Copper conductor cross section mm Current capacity in A Installation Method Connecting lead in free air or perforated tray Number of simultaneous loaded conductors on 1x 0 1x 0 each tray Reduction Factor Copper conductor cross section mm Current capacity in A

183 Installation Method Connecting lead in free air or perforated tray Number of simultaneous loaded conductors on 1x 0 1x 0 each tray Reduction Factor Copper conductor cross section mm Current capacity in A Installation Method Connecting lead in free air or perforated tray Number of simultaneous loaded conductors on 1x 0 1x 0 each tray Reduction Factor Copper conductor cross section mm Current capacity in A

184 Copper conductor cross section mm Reduction Factor Number of simultaneous loaded conductors on each tray Installation Method ³ fixed on a ceiling or under floor Current Carrying capacity in A on floor or wall In conduit in a void or in a pipe Current Carrying capacity in A Wires & Cables 183

185 R Next is ReadyTM HEAD OFFICE 6/7, Errabalu Chetty Street, Chennai India. Tel : / Fax : sales@siechem.com Web : Approvals & Licenses ISO OHSAS DGQA TUV RDSO AERB IHQ Indian Navy DSIR FACTORY RS 104/8 & 105/7, Sedarapet Main Road, Pondicherry India. Tel : / Fax : admn@siechem.com Web : All information given are in good faith. Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction.

Ship Wiring and Marine Cables

Ship Wiring and Marine Cables Ship Wiring and Marine Cables Photo: HELUKABEL Ship Wiring and Marine Cables 1 Ship Wiring and Marine Cables We offer ship wiring and marine cables with approvals from Germanischer Lloyd, Lloyds Register

More information

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD. POLYCAB PVC INSULATED SINGLE CORE UNSHEATHED INDUSTRIAL (MULTISTRAND) CABLES - FLAME RETARDANT (FR) CONFORMING TO IS-694:1990 WITH BRIGHT ANNEALED ELECTROLYTIC BARE COPPER CONDUCTOR FOR VOLTAGE GRADE 1100

More information

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD. Size (sq.mm.) 0.75 (Amps) 7 830 880 950 (No. of 28 12 1 12 1070 1130 1230 24 12 1.5 16 1600 1690 1840 16 10 2.5 22 2580 2730 2960 12 6 4 29 3800 4030 4370 8 4 6 37 5640 5980 6490 6 3 10 51 9920 10520 11410

More information

is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire.

is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire. is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire. We are a major supplier of housewiring, low voltage, power and fire resistant cables for

More information

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD. POLYCAB INDUSTRIAL JELLY FLOODED COAXIAL CABLES Polycab Gas Injected Physical Polyethylene Foam Insulation with Laminated Aluminium Tape and Aluminium Wire Braid, Jelly Flooded PVC Black Jacketed Industrial

More information

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD. POLYCAB INDUSTRIAL JELLY FLOODED COAXIAL CABLES Polycab Gas Injected Physical Polyethylene Foam Insulation with Laminated Aluminium Tape and Aluminium Wire Braid, Jelly Flooded PVC Black Jacketed Industrial

More information

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD. Industrial Cables LP No. 01/2018-19 Dtd : 21st May 2018 POLYCAB PVC INSULATED SINGLE CORE UNSHEATHED INDUSTRIAL (MULTISTRAND) CABLES - FLAME RETARDANT LEAD FREE (FRLF) CONFORMING TO IS-694:1990 WITH BRIGHT

More information

LDC Pricelist. ( WEF 1st August 2017 ) "POLYCAB" 4 Pair Unshielded Twisted Pair (UTP) LAN (Computer) Cables. Unarmoured.

LDC Pricelist. ( WEF 1st August 2017 ) POLYCAB 4 Pair Unshielded Twisted Pair (UTP) LAN (Computer) Cables. Unarmoured. INDUSTRIAL JELLY FLOODED COAXIAL CABLES LDC Pricelist LAN (COMPUTER) CABLES "POLYCAB" Gas Injected Physical Polyethylene Foam Insulation with Laminated Aluminium Tape and Aluminium Wire Braid, Jelly Flooded

More information

FlexFlame BFOU(i) 150/250(300)V S3/S7 Instr. cable

FlexFlame BFOU(i) 150/250(300)V S3/S7 Instr. cable Page 1 of 5 5 4 1 2 3 Fire resistant, flame retardant halogen-free instrumentation cable. Mud resistant BFOU(i) 150/250(300)V MGT/EPR/EPR/TCWB/EVA NEK TS 606 CodeS3/S7 Operating temperature : 90 C Operating

More information

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD. Industrial Cables LP No. 05/2018-19 Dtd : 16th November 2018 POLYCAB PVC INSULATED SINGLE CORE UNSHEATHED INDUSTRIAL (MULTISTRAND) CABLES - FLAME RETARDANT LEAD FREE (FRLF) CONFORMING TO IS-694:1990 WITH

More information

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD. POLYCAB INDUSTRIAL JELLY FLOODED COAXIAL CABLES Polycab Gas Injected Physical Polyethylene Foam Insulation with Laminated Aluminium Tape and Aluminium Wire Braid, Jelly Flooded PVC Black Jacketed Industrial

More information

FlexFlame BFOU-XFR(i) 150/250(300)V Instr. cable. Standards applied. IEC EN 50200:2006 Annex E

FlexFlame BFOU-XFR(i) 150/250(300)V Instr. cable. Standards applied. IEC EN 50200:2006 Annex E Page 1 of 5 extended Fire Resistant, flame retardant halogen-free instrumentation cable. Mud resistant BFOU-XFR(i) 150/250(300)V MGT/EPR/EPR/TCWB/EVA Operating temperature : 90 C Operating Voltage : 150/250(300)V

More information

flame Retardant overall screened Instrumentation cables (Multicore)

flame Retardant overall screened Instrumentation cables (Multicore) Caledonian flame Retardant Instrumentation cables www.caledonian-cables.co.uk www.addison-cables.com flame Retardant overall screened Instrumentation cables (Multicore) Re-2X(st)y Re-2X(st)ysWay PVC Outer

More information

Flame Retardant Individual and Overall Screened, Armoured Instrumentation Cables (Multipair)

Flame Retardant Individual and Overall Screened, Armoured Instrumentation Cables (Multipair) Caledonian Flame Retardant Instrumentation Cables www.caledonian-cables.co.uk www.addison-cables.com Flame Retardant Individual and Overall Screened, Armoured Instrumentation Cables (Multipair) RE-2X(st)YSWAY

More information

FR-3S Fire Resistant Cables

FR-3S Fire Resistant Cables FR-3S Fire Resistant Cables APPLICATION This cable is suitable use in fire extinguishing systems to operate sprinklers, control panels, exit lights in high-rise buildings, hotels, hospitals, sub-ways and

More information

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR RAILWAY TECHNOLOGY. den-belitsky / Fotolia

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR RAILWAY TECHNOLOGY. den-belitsky / Fotolia SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR RAILWAY TECHNOLOGY den-belitsky / Fotolia CONTENT OVERVIEW Who we are.........................................................................................................

More information

Type P Drilmar 125-XE Signal & Instrumentation

Type P Drilmar 125-XE Signal & Instrumentation Type P Drilmar 125-XE Signal & Instrumentation Crosslinked Polyolefin Insulated, Drilling Rig and Marine Cable, 600/1000 V Features Engineered for easiest installation. Extra flexible stranding meets IEEE,

More information

Introduction. for over a period 4 decades now. Customer satisfaction has been the prime focus of

Introduction. for over a period 4 decades now. Customer satisfaction has been the prime focus of Introduction GEMSCAB has been associated with marketing and manufacturing Electric s for over a period 4 decades now. Customer satisfaction has been the prime focus GEMSCAB and today it has established

More information

TRATOS OIL&GAS NEK606

TRATOS OIL&GAS NEK606 C A B L E S F O R A M O V I N G W O R L D TRATOS OIL&GAS NEK606 May 2013 Tt 08-13 TRATOS OIL&GAS NEK606 INDEX TRATOS OIL&GAS NEK606 Approvals, quality system and product certification..........................................................................

More information

Type Approval Certificates for factories in Finland and China

Type Approval Certificates for factories in Finland and China 3 Type Approval Certificates for factories in Finland and China ABS BV CCS DNV GL KRS LRS RMRS NK RINA TC 0,6/1kV FI CN FI CN FI CN FI CN FI CN FI CN FI CN FI CN FI CN FI CN FI CN LKM-HF LKM-HF FLEX LKSM-HF

More information

Type P Drilmar 125-XE Signal & Instrumentation

Type P Drilmar 125-XE Signal & Instrumentation Type P Drilmar 125-XE Signal & Instrumentation Crosslinked Polyolefin Insulated, Drilling Rig and Marine Cable, 600/1000 V Features Engineered for easiest installation. Extra flexible stranding meets IEEE,

More information

The cables you need when you need them

The cables you need when you need them The cables you need when you need them Whether you need standard or specialist cables you re looking in the right place. With a massive range available on short lead-times we can deliver the product you

More information

Cables for Railway Technology

Cables for Railway Technology Cables for Railway Technology www.sab-worldwide.com Content q In case that you don t find a suitable cable for your special application, we are always prepared to design a cable according to your individual

More information

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD. Size (sq.mm.) Rate per 90m Coil 0.75 7 770 810 920 28 12 1 12 1000 1050 1200 24 12 1.5 16 1470 1540 1760 16 10 2.5 22 2370 2490 2840 12 6 4 29 3490 3670 4190 8 4 6 37 5200 5460 6240 6 3 10 51 9140 9600

More information

Solid PE Insulated & LAP Sheathed Air Core/Jelly Filled Cables to DIN VDE 0816

Solid PE Insulated & LAP Sheathed Air Core/Jelly Filled Cables to DIN VDE 0816 Solid PE Insulated & LAP Sheathed Air Core/Jelly Filled Cables to DIN VDE 0816 APPLICATION The cables are designed for use as connection between central fices. The cables are suitable for installation

More information

FlexFlame RFOU(i) 150/250(300)V S1/S5 Instr. cable

FlexFlame RFOU(i) 150/250(300)V S1/S5 Instr. cable Page 1 5 1 1 1 2 3 Flame retardant halogen-free instrumentation cable. Mud resistant RFOU(i) 150/250(300)V EPR/EPR/TCWB/EVA NEK TS 606 CodeS1/S5 Operating temperature : 90 C Operating Voltage : 150/250(300)V

More information

Insulation Colours: Orange (Standard) Natural Natural. Sheath Colours: Orange (Standard) Orange (Standard) Bedding: Black

Insulation Colours: Orange (Standard) Natural Natural. Sheath Colours: Orange (Standard) Orange (Standard) Bedding: Black -I Insulated, non-sheathed Insulated and sheathed Insulated, ed and sheathed 1. : Plain stranded annealed Class 2 Copper. 1.5mm 2 up to 630mm 2 Plain stranded annealed Class 2 Copper. Plain stranded annealed

More information

0.6/1KV FLAME RETARDANT ARMORED & SHEATHED CABLE PRODUCT CONSTRUCTION 1. CONDUCTOR

0.6/1KV FLAME RETARDANT ARMORED & SHEATHED CABLE PRODUCT CONSTRUCTION 1. CONDUCTOR TIOI CABLE 0.6/1KV FLAME RETARDANT ARMORED & SHEATHED CABLE 1 2 3 4 5 ICC CABLE CORP. PRODUCT DESCRIPTION 0.6/1KV ONE - FIVE CONDUCTOR, MULTI-CONDUCTOR COMMERCIAL MARINE POWER & CONTROL CABLE 90 C TEMPERATURE

More information

SINCE 1989 Quality Products, Prompt Services, Trustful Relationships www.kmindustrialcorp.com KM Industrial Corporation has established itself as a trusted supplier of Electrical, Machinery and Industry

More information

Power & Control Cable IEC

Power & Control Cable IEC (2-, 3-, 4,- and 5-cores) U 0 Application For electricity supply and control in public networks and industrial plants; suitable for use in zone 1 and zone 2 group ΙΙ classified areas (IEC 60079-14). Recoended

More information

Power & Control Cables

Power & Control Cables The Quality Connection Power & Control Cables U o /U 0.6/1 kv - IEC 60502-1 2 The Quality Connection www.leoni-industrial-projects.com The LEONI Group Cable expertise for the most various industrial markets.

More information

BS EN Natural. (Orange for Non-sheathed) (Red & Black) or (Brown & Blue) (Red, Yellow, Blue) or (Brown, Black, Grey)

BS EN Natural. (Orange for Non-sheathed) (Red & Black) or (Brown & Blue) (Red, Yellow, Blue) or (Brown, Black, Grey) LOW SMOKE HALOGEN FREE (LSHF) FIRE RESISTANT CABLES Voltage Rating (Uo/U) : /0V, /7V or 00/00V Standards Complied Main Specification Fire Tests Flame Retardant Test Test on Acid Gas Evolved Smoke Density

More information

CABLES FOR AUTOMOTIVE MARKET Sensor and multimedia cables. Catalogue

CABLES FOR AUTOMOTIVE MARKET Sensor and multimedia cables. Catalogue CABLES FOR AUTOMOTIVE MARKET Sensor and multimedia cables Catalogue Introduction Nexans has developed a range of special and customised cables for the automotive market. This cable range covers two main

More information

VDE tested single cores according to EN (H05Z-K & H07Z-K) for more demanding requirements

VDE tested single cores according to EN (H05Z-K & H07Z-K) for more demanding requirements VDE tested single cores according to EN 50525-3-41 (H05Z-K & H07Z-K) for more demanding requirements ÖLFLEX HEAT 125 C MC - halogen free single core with GL certificate, special fire performance, IEC 60332-3,

More information

Caledonian Fire Resistant Optic Fiber Cables

Caledonian Fire Resistant Optic Fiber Cables Fire Resistant Optic Cables Fire resistant Central Loose Optic cables Application These cables are characterized by light weight and small diameter, suitable for both aerial and duct installation. They

More information

Technical Data Sheet Unshielded (YY) PVC Control Cable

Technical Data Sheet Unshielded (YY) PVC Control Cable MachineTuff Cables Applications Designed for applications which are installed in occasional flexing and fixed locations. Cable applications include precision control sensors, multi axis control machines,

More information

Technical Data Sheet Shielded (CY) PVC Control Cable

Technical Data Sheet Shielded (CY) PVC Control Cable MachineTuff Cables Tinned Copper Braid Shield (TCB) Excellent Noise Immunity Applications Designed for applications which are installed in occasional flexing and fixed locations. Cable applications include

More information

Control Cable Type P 600/1000 volts DRILMAR 125-XE Crosslinked Polyolefin Insulated Drilling Rig and Marine Cable

Control Cable Type P 600/1000 volts DRILMAR 125-XE Crosslinked Polyolefin Insulated Drilling Rig and Marine Cable CP Jacket (overall optional) Armor (optional) CP Jacket Flexible Tin Coated Copper ed Color Coded XLPO Polyolefin Insulation 600/1000 volts Features Engineered for easiest installation. Extra flexible

More information

PRODUCT INFORMATION ÖLFLEX HEAT 125 C MC. Info Improved characteristics in the event of a fire GL - Germanischer Lloyd approved

PRODUCT INFORMATION ÖLFLEX HEAT 125 C MC. Info Improved characteristics in the event of a fire GL - Germanischer Lloyd approved Electron beam cross-linked cables for more demanding application requirements - halogen free shielded control cable with GL certificate, special fire performance, IEC 60332-3, suitable for +125 C Info

More information

0.6/1KV FLAME RETARDANT UNARMORED CABLE PRODUCT CONSTRUCTION 1. CONDUCTOR CROSS-LINKED POLYETHYLENE (XLPE) IEEE 1580 COLOR CODE 3.

0.6/1KV FLAME RETARDANT UNARMORED CABLE PRODUCT CONSTRUCTION 1. CONDUCTOR CROSS-LINKED POLYETHYLENE (XLPE) IEEE 1580 COLOR CODE 3. TI CABLE 0.6/1KV FLAME RETARDANT UNARMORED CABLE 1 2 3 ICC CABLE CORP. PRODUCT DESCRIPTION 0.6/1KV ONE - FIVE CONDUCTOR, MULTI-CONDUCTOR COMMERCIAL MARINE POWER & CONTROL CABLE 90 C TEMPERATURE RATING

More information

Gexol. Gexol. World Class Oil & Gas Cables. The Global Cable Solutions Company

Gexol. Gexol. World Class Oil & Gas Cables. The Global Cable Solutions Company Gexol Gexol World Class World Class Mission-critical designed for safe, reliable performance in extremely hazardous operating environments Power Control Instrumentation VFD MMV Assembly Solutions The Global

More information

Technical Data Sheet Shielded (CY) PVC Control Cable

Technical Data Sheet Shielded (CY) PVC Control Cable Technical Data Sheet Shielded (CY) PVC Control Cable MachFlex 350 CY VDE Registered Tinned Copper Braid Shield (TCB) Excellent Noise Immunity Applications Designed for applications which are installed

More information

Unarmoured Single-Core Cables to BS6883

Unarmoured Single-Core Cables to BS6883 Unarmoured Single-Core Cables to BS TAC. EPR. SW 00/00 V 1 Application Unarmoured cable for use where mechanical protection is not required for fixed wiring in ships and in mobile and fixed offshore units

More information

Caledonian. Caledonian Offshore & Marine Cables. BS 6883 STANDARD (Flame Retardant) BS 7917 STANDARD (Fire Resisitant)

Caledonian. Caledonian Offshore & Marine Cables. BS 6883 STANDARD (Flame Retardant) BS 7917 STANDARD (Fire Resisitant) Caledonian Caledonian Offshore & Marine Cables BS 6883 STANDARD (Flame Retardant) BS 7917 STANDARD (Fire Resisitant) Caledonian, established in 1978, offers one of the most complete lines of fiber and

More information

Materials Evolved* BS EN BS EN IEC IEC (Upon customer request) (Red, Black) or (Brown, Blue)

Materials Evolved* BS EN BS EN IEC IEC (Upon customer request) (Red, Black) or (Brown, Blue) XLPE INSULATED AND PVC OR LOW SMOKE HALOGEN FREE (LSHF) SHEATHED CABLES Voltage Rating (Uo/U) : 00/00V, 1/0V or 00/3V Standards Complied Main Specification Materials Test Methods Flame Retardant Test Test

More information

INDUSTRIAL SOLUTIONS MARINE CATALOGUE INNOVATIVE CABLE SOLUTIONS MEETING INTERNATIONAL STANDARDS

INDUSTRIAL SOLUTIONS MARINE CATALOGUE INNOVATIVE CABLE SOLUTIONS MEETING INTERNATIONAL STANDARDS INDUSTRIAL SOLUTIONS MARINE CATALOGUE INNOVATIVE CABLE SOLUTIONS MEETING INTERNATIONAL STANDARDS TKF TECHNOLOGICAL LEADERSHIP IN CONNECTIVITY SOLUTIONS Since its establishment in 1930 TKF developed from

More information

THERMOCOUPLE CABLE. Compensating & Extension Make Up: Solid or stranded conductor Conductor of required thermocouple type Iron constantan Jx

THERMOCOUPLE CABLE. Compensating & Extension Make Up: Solid or stranded conductor Conductor of required thermocouple type Iron constantan Jx THERMOCOUPLE CABLE Customization Customized colour option and printing of the outer sheath on request Compensating & Extension 1601 Application: Compensating or Extension Cables are used in temperature

More information

INFORMATION. Hybrid cables. Description

INFORMATION. Hybrid cables. Description Description INFORMATION This chapter shows the technical data of the hybrid cables available at SEW EURODRIVE. For assignment of hybrid cables to the products, refer to the respective chapters..1 Description

More information

www. h itech controls.com (800) I (303) Click or Call for a Quotel Photo: HELUKABEL Robotic Cables C HELUKABEL

www. h itech controls.com (800) I (303) Click or Call for a Quotel Photo: HELUKABEL Robotic Cables C HELUKABEL Photo: HELUKABEL Robotic Cables Robotic Cables With over 30 years of experience with cables and lines, we also have the right solutions for the demands placed on the components to be installed by the applications

More information

PVC INSULATED HEAVY DUTY CABLES

PVC INSULATED HEAVY DUTY CABLES PVC INSULATED HEAVY DUTY CABLES 1100 V. 9001:2008 14001:2004 OHSAS 18001:2007 Details make the Difference IS 1554 (Part I) Product Range L.V. PVC & XLPE POWER CABLES WITH COPPER AND ALUMINIUM CONDUCTOR

More information

Standardization IEC /-351/-353. Conductor material

Standardization IEC /-351/-353. Conductor material Low voltage power cables Fire resistant low voltage power cables according to the new demanding IEC -60331 1/2 specifications for power and lighting applications in all ship areas, with reduced diameter

More information

Introduction. Phone (888) Fax (800) Int l Phone Int l Fax

Introduction. Phone (888) Fax (800) Int l Phone Int l Fax Introduction General Cable is a world leader in cable manufacture and one of the world s largest suppliers to the Offshore and sector. General Cable s extensive experience in the offshore market translates

More information

600/1000 V. 5. Flame Retardancy VDE , DIN EN , IEC

600/1000 V. 5. Flame Retardancy VDE , DIN EN , IEC MachineTuff Cables Low Voltage Control & Power Cable Galvanized Steel Wire Braid Armored (GSWB) > Excellent Mechanical Protection Applications Designed for applications which are installed in occasional

More information

Detailed Specifications & Technical Data

Detailed Specifications & Technical Data Description: 20 AWG stranded (7x28).038" tinned copper conductors, polyethylene insulation, Beldfoil (100% coverage) plus a tinned copper braid shield (55% coverage), sunlight-resistant PVC jacket. Physical

More information

Power & Control Cable IEC

Power & Control Cable IEC (2-, 3-, and 4-cores) U 0 Application For electricity supply and control in public networks and industrial plants; suitable for use in zone 1 and zone 2 group ΙΙ classified areas (IEC 60079-14). Recoended

More information

Type P Drilmar 125-XE Power/Distribution Cable Multiconductor

Type P Drilmar 125-XE Power/Distribution Cable Multiconductor Type P Drilmar 125-XE Power/Distribution Cable Multiconductor Crosslinked Polyolefin Insulated, Drilling Rig and Marine Cable, 600/1000 V Features Engineered for easiest installation. Extra flexible stranding

More information

I N T R O D U C T I O N

I N T R O D U C T I O N I N T R O D U C T I O N GEMSCAB are being manufactured by the people who have been associated with the industry for over years and understand the requirements their valued customers. The company took up

More information

SPECIFICATION S VR 1(4) HALOGEN FREE POWER AND CONTROL CABLE FOR MARINE APPLICATIONS LM-HF 0,6/1 kv and TEMAR PHFX-U 0,6/1 kv APPLICATI

SPECIFICATION S VR 1(4) HALOGEN FREE POWER AND CONTROL CABLE FOR MARINE APPLICATIONS LM-HF 0,6/1 kv and TEMAR PHFX-U 0,6/1 kv APPLICATI 1(4) HALOGEN FREE POWER AND CONTROL CABLE FOR MARINE APPLICATIONS LM-HF 0,6/1 kv and TEMAR PHFX-U 0,6/1 kv APPLICATION Power and control cable for fixed installations. Designed to fulfill requirements

More information

Power & Control Cables. U o. /U 0.6/1 kv - IEC

Power & Control Cables. U o. /U 0.6/1 kv - IEC Power & Control Cables U o /U 0.6/1 kv - IEC 60502-1 2 KERPEN GmbH & Co. KG 07.2005 Printing errors excepted. Subject to alteration List of Contents Introduction Page B1 Construction Page B3 Use Page B4

More information

GEMSCAB has been associated with marketing and manufacturing of Electric Cables

GEMSCAB has been associated with marketing and manufacturing of Electric Cables I NTRODUCTION GEMSCAB has been associated with marketing and manufacturing Electric Cables for over a period 4 decades now. Customer satisfaction has been the prime focus GEMSCAB and today it has established

More information

Telephone Cables Fire Warning Cables

Telephone Cables Fire Warning Cables Telephone Cables Fire Warning Cables Telephone Cables Fire Warning Cables As supplier of underground cables, telephone cables for indoor and outdoor lying, as well as fire warning cables (also the halogen-free

More information

CRANE, CONVEYOR, LIFT & REELING CABLES

CRANE, CONVEYOR, LIFT & REELING CABLES CRANE, CONVEYOR, LIFT & REELING CABLES F-PVC Series... 158 F-TPECY Series...160 P Series...161 PR Series...162 PRRT Series... 164 PRVS Series...166 Reeling/Trailing Cable Enquiry Form...168 P: (09) 264

More information

Corflex. Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables. Introduction Applications... 3

Corflex. Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables. Introduction Applications... 3 Corflex Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables Introduction................................. 2 Applications................................. 3 Corflex PL 300V Instrumentation

More information

FR-N1X1G1. Low voltage - Energy, cabling, signalling and control

FR-N1X1G1. Low voltage - Energy, cabling, signalling and control Low voltage - Energy, cabling, signalling and control FR-N1X1G1 Construction: NF C 32-323 NF C 32-323/1 Fire propagation: NF EN 60332-3-24 NF C 32-070 C1 IEC 60332-3-24 C Flame propagation: NF EN 60332-1-2

More information

PRODUCT INFORMATION. UNITRONIC LiYCY. Benefits Overall shield minimises electrical interference Versatile application possibilities

PRODUCT INFORMATION. UNITRONIC LiYCY. Benefits Overall shield minimises electrical interference Versatile application possibilities Shielded data cable with colour code according to DIN 47100 - shielded PVC data cable with colour code DIN 47100 for use in machinery and apparatus construction and in measurement, control and regulation

More information

HIGH TEMPERATURE CABLES

HIGH TEMPERATURE CABLES HIGH TEMPERATURE CABLES C O N T E N T S DEF 61-12 Part 18 Type 1 LFH Equipment Wires :2 Technical Information for DEF 61-12 :8 PTFE Insulated Equipment Wire Single Core :10 PTFE EFGLAS Aircraft Cable :12

More information

ÖLFLEX CLASSIC 135 CH -halogen-free control cable, HFFR, flexible and screened for various applications, U 0 /U: 300/500V

ÖLFLEX CLASSIC 135 CH -halogen-free control cable, HFFR, flexible and screened for various applications, U 0 /U: 300/500V PRODUCT INFORMATION Screened halogen-free control cable with improved fire characteristics -halogen-free control cable, HFFR, flexible and screened for various applications, U 0 /U: 300/500V Info CPR:

More information

Data sheet chainflex CF8821

Data sheet chainflex CF8821 1. Outer jacket: Pressure extruded, oil-resistant PVC mixture 2. Overall shield: Braiding made of tinned copper wires 3. Overall banding: Plastic foil 4. Core insulation: Mechanically high-quality TPE

More information

Technical Data Sheet Unshielded (YY) PVC Control Cable

Technical Data Sheet Unshielded (YY) PVC Control Cable Technical Data Sheet Unshielded (YY) PVC Control Cable MachFlex 350 YY VDE Registered Flexible PVC Control Cables Applications Designed for applications which are installed in occasional flexing and fixed

More information

BlueLine Cables for Shipbuilding

BlueLine Cables for Shipbuilding BlueLine Cables for Shipbuilding www.sab-worldwide.com Content page The Company..........................................................................................................................

More information

Technical Data Sheet Shielded (CY) PVC Control Cable

Technical Data Sheet Shielded (CY) PVC Control Cable Technical Data Sheet Shielded (CY) PVC Control Cable MachFlex 375 CY Tinned Copper Braid Shield (TCB) Excellent Noise Immunity Applications Designed for applications which are installed in occasional flexing

More information

600/1000V XLPE Insulated, LSZH Sheathed, Armoured Power Cables (2-5 Cores)

600/1000V XLPE Insulated, LSZH Sheathed, Armoured Power Cables (2-5 Cores) www.caledonian-s.co.uk www.addison-s.com 600/1000V XLPE Insulated, LSZH Sheathed, Armoured Power Cables (2-5 Cores) FTX400 1RZ1-R (CU/XLPE/LSZH 600/1000V Class 2) FTX400 1RZ1MZ1-R (CU/XLPE/LSZH/SWA/LSZH

More information

Easier! Faster! Safer!

Easier! Faster! Safer! Gexol CIR Crush and Impact Resistant Without External Armoring Passes the same stringent crush and impact testing required by UL 2225 for Type MC-HL Index CIR Power Cables Three & Four Conductor + Ground...

More information

Rubber was the first insulant to be used in Electric Cable manufacture but gave way to other insulants like paper, PVC, XLPE etc.

Rubber was the first insulant to be used in Electric Cable manufacture but gave way to other insulants like paper, PVC, XLPE etc. INTRODUCTION : Rubber was the first insulant to be used in Electric Cable manufacture but gave way to other insulants like paper, PVC, XLPE etc. Rubber is still considered the preferred insulation for

More information

RE-T2X(st)H SWAH - BS EN Mica XLPE / LSZH / CAM / SWA / LSZH Cable

RE-T2X(st)H SWAH - BS EN Mica XLPE / LSZH / CAM / SWA / LSZH Cable RE-T2X(st)H SWAH - BS EN 50288-7 Mica XLPE / LSZH / CAM / SWA / LSZH Cable Eland Product Group: I APPLICATION These cables are designed to connect electrical instrument circuits and provide counication

More information

PVC motor cables unshielded

PVC motor cables unshielded PVC motor cables unshielded LÜTZE-SILFLEX M PVC Motor connecting/energy supply cable Motor connecting cable and energy supply cable in machine and apparatus engineering, transport and conveyor technology,

More information

Data sheet chainflex CF240

Data sheet chainflex CF240 1. Outer jacket: Pressure extruded, oil-resistant PVC mixture 2. Overall shield: Aluminum/Polyester tape and extremely bending-resistant braiding made of tinned copper wires. 3. Banding: Plastic foil 4.

More information

Details make the Difference

Details make the Difference 9001:2008 14001:2004 OHSAS 18001:2007 IS 7098 (Part I) Details make the Difference XLPE INSULATED HEAVY DUTY CABLES 650/1100V. Product Range L.V. PVC & XLPE POWER CABLES WITH COPPER AND ALUMINIUM CONDUCTOR

More information

20 HUBER+SUHNER RADOX SOLAR

20 HUBER+SUHNER RADOX SOLAR All our cables fully comply with the European directives 76/769/EWG, 2003/11/EG, 2000/53/EG, 2003/53/EG and 2002/95/EG (RoHS) and the requirements of REACH Nr. EC1907/2006. 20 RADOX SOLAR cables RADOX

More information

List of Malaysian Standard (MS) for Cables. Prepared by MCMA SWO. Cable - Armoured. Cable - Armoured

List of Malaysian Standard (MS) for Cables. Prepared by MCMA SWO. Cable - Armoured. Cable - Armoured List of Malaysian Standard (MS) for Cables Prepared by MCMA SWO NO. PUBLICATIONS 1. MS 2100 : 2007 2. MS 2101 : 2007 3. MS 2102 : 2007 4. MS 2103 : 2007 5. MS 2104 : 2007 6. MS 2105 : 2007 7. MS 2106 :

More information

SABIX Ultra. Standards: EN EN Cat C or D IEC (halogen-free)

SABIX Ultra. Standards: EN EN Cat C or D IEC (halogen-free) SABIX Ultra Standards: EN 60332-1-2 EN 60332-3 Cat C or D IEC 60754-1 (halogen-free) IEC 60754-2 + EN 50267-2-2 (corrosivity of gases) EN 61034 (smoke density) NF C 32-70 C1 (fire performance acc. to French

More information

Any inquiries, please feel free to contact or Caledonian

Any inquiries, please feel free to contact or Caledonian Caledonian Low Voltage cables to IEC 60502 Standard www.caledonian-cables.co.uk www.caledonian-cables.net 1 Addison Company Profile Caledonian. established in 1978.offers one of the most complete lines

More information

PRODUCT INFORMATION MULTI-STANDARD SC 2.1. U.I. Lapp GmbH

PRODUCT INFORMATION MULTI-STANDARD SC 2.1. U.I. Lapp GmbH GmbH PRODUCT INFORMATION USA: UL-listed (MTW), Canada: CSA (TEW), Europe: H07V-K (depending on cross s.), tin-coated strands For use in the most important global markets Reduction in technical documentation

More information

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING BLUELINE - CABLES FOR SHIPBUILDING.

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING BLUELINE - CABLES FOR SHIPBUILDING. SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING BLUELINE - CABLES FOR SHIPBUILDING www.sab-kabel.de CONTENT OVERVIEW Who we are.........................................................................................................

More information

Electronic Instrumentation

Electronic Instrumentation Applications Electronic instrumentation, analog and digital signal circuits (4-20mA). Intrinsically safe circuits. Gas and/or fluid leak detection systems. Pressure, temperature and volume measuring and

More information

CORDAFLEX(SMK) (N)SHTÖU Tough Rubber-Sheathed Reeling Cables

CORDAFLEX(SMK) (N)SHTÖU Tough Rubber-Sheathed Reeling Cables CORDAFLEX(SMK) (N)SHTÖU Tough Rubber-Sheathed Reeling Cables 3 SK1_1-001.tif 4 SK1_1-003.tif SK1_1-00.tif Selection and dimensioning criteria Refer to Section 4 for further details Ü Type CORDAFLEX(SMK)

More information

Technical data sheet LÜTZE SUPERFLEX PLUS M (C) PUR SERVO 0.6/1 kv Supply line for Bosch Rexroth and other systems For highest requirements

Technical data sheet LÜTZE SUPERFLEX PLUS M (C) PUR SERVO 0.6/1 kv Supply line for Bosch Rexroth and other systems For highest requirements PVC servo cables C-track compatible shielded Subject to technical modification 111270 Identification Type SU+M(C)P SE(4G1,0+2 (2 0,75))UL 1KV OR INK Description* INK 0653 Use/Application/Properties Application

More information

ÖLFLEX CLASSIC 110 H Info Benefits

ÖLFLEX CLASSIC 110 H Info Benefits Halogen-free control cable, oil resistant and very flexible - halogen-free control cable, HFFR, oil-resistant, very flexible and cold-resistant down to -30 C for various applications, CPR Info CPR: Article

More information

Wires that don t catch fire

Wires that don t catch fire Wires that don t catch fire Havells range of heat resistant & flame retardant wires w.e.f. 1st July, 2017 HRFR/FR-LSH/HFFR/ PVC Insulated Industrial Cables Multicore Round PVC Cables Flat Three Core Industrial

More information

600/1000V XLPE Insulated PVC Sheathed Power Cables (Multicore)

600/1000V XLPE Insulated PVC Sheathed Power Cables (Multicore) 600/1000V XLPE Insulated PVC Sheathed Power Cables (Multicore) FGD400 1RV-R (CU/XLPE/PVC 600/1000V Class 2) Outdoor Cabling Earth Conductor Earth Conductor APPLICATION The cables are mainly used in power

More information

Power & Control Cable IEC

Power & Control Cable IEC (2-, 3-, and 4-cores) U 0 PVC-Insulation, Application For electricity supply and control in public networks and industrial plants; suitable for use in zone 1 and zone 2 group ΙΙ classified areas (IEC 60079-14).

More information

X X. Marine Cables Zero Halogen X X X X X X. UK Defence Standard (part 25) X X. Limited Fire Hazard

X X. Marine Cables Zero Halogen X X X X X X. UK Defence Standard (part 25) X X. Limited Fire Hazard Limited Fire Hazard Marine Cables Zero Halogen UK Defence Standard 61-12 (part 25) Introduction Spliers to the Naval & Defence Market Zerohal Marine Cables The s in this guide are manufactured and approved

More information

Data sheet chainflex CF210.UL

Data sheet chainflex CF210.UL For detailed overview please see design table 1. Outer jacket: Pressure extruded, oil-resistant PVC mixture 2. Overall shield: Bending-resistant braiding made of tinned copper wires. 3. Banding: Plastic

More information

ÖLFLEX CLASSIC 115 CY

ÖLFLEX CLASSIC 115 CY Screened PVC control cable with small outer diameter - PVC control cable, screened and flexible for various applications, thin and light without inner sheath, U 0 /U: 300/500V Info CPR: choice under www.lappkabel.com/cpr

More information

Traction Cable Radox 3 GKW/S EMC

Traction Cable Radox 3 GKW/S EMC General Properties : Excellent high temperature, low temperature, oil, diesel oil, ozone and weathering resistance, zero halogen, flame retardant, solder iron resistant, easily strippable, flexible, excellent

More information

CiMEC Technologies Pvt. Ltd., 23/H, Meldi Estate, Gota, Ahmedabad, Gujarat. Discipline Electrical Testing Issue Date

CiMEC Technologies Pvt. Ltd., 23/H, Meldi Estate, Gota, Ahmedabad, Gujarat. Discipline Electrical Testing Issue Date Last Amended on - Page 1 of 6 I. CABLES AND ACCESSORIES 1. PVC Insulated Cables Tests on Conductor: Annealing Test (copper) IS 10810 (Part 1):1984 (RA 2011) 0 to 50 % Tensile Test (Aluminium) IS 10810

More information

Price List "NATIONAL" PVC FLEXIBLE CABLES COPPER CONDUCTOR 1.1 KV CONFORMING TO IS:694/2010. Size Twin Two Three Four

Price List NATIONAL PVC FLEXIBLE CABLES COPPER CONDUCTOR 1.1 KV CONFORMING TO IS:694/2010. Size Twin Two Three Four Price List HSN Code : 8544 w.e.f. : 01.06.2018 "NATIONAL" PVC FLEXIBLE CABLE WITH COPPER CONDUCTOR SINGLE CORE 1.1 KV CONFORMING TO IS:694/2010. "NATIONAL" PVC FLEXIBLE CABLES COPPER CONDUCTOR 1.1 KV CONFORMING

More information

DKSH provides expertise and solutions to industry

DKSH provides expertise and solutions to industry Business Unit Technology DKSH provides expertise and solutions to industry Industrial Services Australia Our Profile Locations VICTORIA (Head Office) 14-17 Dansu Court Hallam VIC 3803 Tel: +61 3 9554 6666

More information

ÖLFLEX VFD 2XL - screened VFD cable for fixed installation or occasional flexing with UL TC-ER.

ÖLFLEX VFD 2XL - screened VFD cable for fixed installation or occasional flexing with UL TC-ER. Multi-listed, flexible VFD cable - screened VFD cable for fixed installation or occasional flexing with UL TC-ER. Info VFD drive and motor connections Wide application range (NFPA 70/NEC)/ compliance with

More information

Caledonian Flame Retardant RS485 Databus Cables

Caledonian Flame Retardant RS485 Databus Cables Flame Retardant RS485 Databus Cables Copper Wire Braid(optional) Individual AL/Polyester Tape(optional) Foam PE/Foam skin PE. Stranded Tinned Copper AL/Polyester Tape With Tinned Copper Drain Wire PVC

More information