1 IRE 125 The IRE 125 insulated duct fan is fitted oth motor and impeller are easy to clean The fans can also be supplied with a removable impeller (non-standard). Insulated duct fan type IRE 125 IRE 125 IRE 125 urve in diagram Voltage V urrent 0,27 0,42 0,53 Input W Speed range Rpm Sound preassure level* d () Wiring diagram No Weight Kg *ll d()-values are related to an effective absorption area of10 m Flow m 3 L /s L p w d () Inlet duct IRE 125 0,06 Outlet duct Fan room Inlet duct IRE 125 0,08 Outlet duct Fan room ,10 Inlet duct IRE Outlet duct Fan room

2 IRE 160 The IRE 160 insulated duct fan is fitted oth motor and impeller are easy to clean The fans can also be supplied with a removable impeller (non-standard). Insulated duct fan type IRE 160 IRE 160 IRE 160 urve in diagram Voltage V urrent 0,46 0,55 0,63 Input W Speed range Rpm Sound preassure level* d () Wiring diagram No Weight Kg *ll d()-values are related to an effective absorption area of 10 m 2 50 Flow m 3 L /s L p w d () Inlet duct IRE 160 0,08 Outlet duct Fan room Inlet duct IRE 160 0,12 Outlet duct Fan room IRE 160 0,14 Inlet duct Outlet duct Fan room

3 IRE 200 The IRE 200 and insulated duct fan is fitted with a single inlet radial fan with backward-cur ved impeller. oth motor and impeller are easy to clean Insulated duct fan type IRE 200 IRE 200 urve in diagram Voltage V urrent 0,49 0,57 Input W Speed range Rpm Sound preassure level* d () Wiring diagram No 1 1 Weight Kg *ll d()-values are related to an effective absorption area of10 m 2 Flow m 3 L /s L p w d () IRE 200 0, IRE 200 0, ll sound data are measured with full speed Symbols: : Total -weighted sound power level d() (ref W)=the sum of the sound power level in the octave ranges Hz. : -weighted sound power level in octave range d() (ref W). L p : -weighted sound preassure level in d() according to normed -weighting correction and related to an effective absorption area of 10m 2. We preserve the right to changes without further notice. Inlet duct Outlet duct Fan room Inlet duct Outlet duct Fan room

4 IRE 200, 250 The IRE 200 and 250 insulated duct fan is fitted with a double inlet radial fan with forward-cur ved impeller, providing high preassure with a low sound level. The radial fan can be removed for cleaning. Insulated duct fan type IRE 200 IRE 250 urve in diagram Voltage V urrent 0,83 1,28 Input W Speed range Rpm Sound preassure level* d () Wiring diagram No 1 1 Weight Kg *ll d()-values are related to an effective absorption area of 10 m Flow m 3 L /s L p w d () IRE 200 0, IRE 250 0, ll sound data are measured with full speed Symbols: : Total -weighted sound power level d() (ref W)=the sum of the sound power level in the octave ranges Hz. : -weighted sound power level in octave range d() (ref W). L p : -weighted sound preassure level in d() according to normed -weighting correction and related to an effective absorption area of 10m 2. We preserve the right to changes without further notice. Inlet duct Outlet duct Fan room Inlet duct Outlet duct Fan room

5 IRE X 20 The IRE 250 insulated duct fan is fitted oth motor and impeller are easy to clean Insulated duct fan type IRE 250 IRE 250 Insulated duct fan type IRE 40x20 IRE 40x20 urve in diagram Voltage V urrent 0,63 1,72 Input W Speed range Rpm Sound preassure level* d () Wiring diagram No 1 1 Weight Kg *ll d()-values are related to an effective absorption area of 10 m Rectangular ircular IRE 40x20 IRE 250 0, IRE 40x20 IRE 250 0, ll sound data are measured with full speed Symbols: : Total -weighted sound power level d() (ref W)=the sum of the sound power level in the octave ranges Hz. : -weighted sound power level in octave range d() (ref W). L p : -weighted sound preassure level in d() according to normed -weighting correction and related to an effective absorption area of 10m 2. We preserve the right to changes without further notice. L p d () Inlet duct Outlet duct Fan room Inlet duct Outlet duct Fan room

6 IRE X 20 The 250 IRE insulated duct fan is fitted oth motor and impeller are easy to clean Insulated duct fan type IRE 250 IRE 250 E Insulated duct fan type IRE 40x20 IRE 40x20 E urve in diagram E Voltage V urrent 0,67 0,89 Input W Speed range Rpm Sound preassure level* d () Wiring diagram No 1 1 Weight Kg *ll d()-values are related to an effective absorption area of 10 m 2 E 50 E Rectangular ircular IRE 40x20 IRE 250 0, IRE 40x20 E IRE 250 E 0, ll sound data are measured with full speed Symbols: : Total -weighted sound power level d() (ref W)=the sum of the sound power level in the octave ranges Hz. : -weighted sound power level in octave range d() (ref W). L p : -weighted sound preassure level in d() according to normed -weighting correction and related to an effective absorption area of 10m 2. We preserve the right to changes without further notice L p d () Inlet duct Outlet duct Fan room Inlet duct Outlet duct Fan room

7 IRE x 25 The IRE 315 insulated duct fan is fitted oth motor and impeller are easy to clean Insulated duct fan type IRE 315 IRE 315 Insulated duct fan type IRE 50x25 IRE 50x25 urve in diagram Voltage V urrent 1,21 2,76 Input W Speed range Rpm Sound preassure level* d () Wiring diagram No 1 1 Weight Kg *ll d()-values are related to an effective absorption area of 10 m Rectangular ircular IRE 50x25 IRE 315 0, IRE 50x25 IRE 315 0, L p d () Inlet duct Outlet duct Fan room Inlet duct Outlet duct Fan room

8 IRE x 30 The IRE 400 insulated duct fan is fitted oth motor and impeller are easy to clean Insulated duct fan type IRE 400 IRE 400 F Insulated duct fan type IRE 50x30 IRE 50x30 F urve in diagram F Voltage V urrent 2,56 4,0 Input kw 0,44 0,86 Speed range Rpm Sound preassure level* d () Wiring diagram No 1 1 Weight Kg *ll d()-values are related to an effective absorption area of10 m 2 90 F F Rectangular ircular IRE 50x30 IRE 400 0, IRE 50x30 F IRE 400 F 0, L p d () Inlet duct Outlet duct Fan room Inlet duct Outlet duct Fan room

9 IRE x 35 The IRE 500 insulated duct fan is fitted oth motor and impeller are easy to clean Insulated duct fan type IRE 500 IRE 500 IRE 500 Insulated duct fan type IRE 60x35 IRE 60x35 IRE 60x35 urve in diagram Voltage V 230/ /400 urrent 3,5/2,0 4,2 5,7/3,3 Input kw 0,90 0,75 1,79 Speed range Rpm Sound preassure level* d () Wiring diagram No 3/4 1 3/4 Weight Kg *ll d()-values are related to an effective absorption area of10 m Rectangular ircular IRE 60x35 IRE 500 0, IRE 60x35 IRE 500 0, IRE 60x35 IRE 500 1, L p d () Inlet duct Outlet duct Fan room Inlet duct Outlet duct Fan room Inlet duct Outlet duct Fan room

10 IRE x 35 The IRE 500 insulated duct fan is fitted oth motor and impeller are easy to clean Insulated duct fan type IRE 500 IRE 500 E IRE 500 F Insulated duct fan type IRE 60x35 IRE 60x35 E IRE 60x35 F urve in diagram E F Voltage V / /400 urrent 8,0 7,6/4,4 11,4/6,6 Input kw 1,78 2,28 3,65 75 Speed range Rpm Sound preassure level* d () Wiring diagram No 1 3/4 3/4 Weight Kg E F *ll d()-values are related to an effective absorption area of10 m E F Rectangular ircular IRE 60x35 IRE 500 0, IRE 60x35 E IRE 500 E 0, IRE 60x35 F IRE 500 F 1, L p d () Inlet duct Outlet duct Fan room Inlet duct Outlet duct Fan room Inlet duct Outlet duct Fan room

11 IRE x 50 The IRE 630 insulated duct fan is fitted oth motor and impeller are easy to clean Insulated duct fan type IRE 630 IRE630 IRE 630 Insulated duct fan type IRE 80x50 IRE 80x50 IRE 80x50 urve in diagram Voltage V 230/ / /400 urrent 4,5/2,5 8,8/4,8 9,5/5,5 Input kw 1,25 2,30 2,70 Speed range Rpm Sound preassure level* d () Wiring diagram No 3/4 3/4 3/4 Weight Kg *ll d()-values are related to an effective absorption area of 10 m Rectangular ircular IRE 80x50 IRE 630 1, IRE 80x50 IRE 630 1, IRE 80x50 IRE 630 1, L p d () Inlet duct Outlet duct Fan room Inlet duct Outlet duct Fan room Inlet duct Outlet duct Fan room

12 IRE x 50 The IRE 630 insulated duct fan is fitted oth motor and impeller are easy to clean Insulated duct fan type IRE 630 IRE 630 E Insulated duct fan type IRE 80x50 IRE 80x50 E urve in diagram E Voltage V 230/ /400 urrent 16/7 12/9,3 Input kw 4,0 5,5 Speed range Rpm Sound preassure level* d () Wiring diagram No 3/4 3/4 Weight Kg *ll d()-values are related to an effective absorption area of 10 m 2 70 E E Rectangular ircular IRE 80x50 IRE 630 1, IRE 80x50 E IRE 630 E 1, ll noise data are measured with full speed Symbols: : Total -weighted sound power level d() (ref W)=the sum of the sound power level in the octave ranges Hz. : -weighted sound power level in octave range d() (ref W). L p : -weighted sound preassure level in d() according to normed -weighting correction and related to an effective absorption area of 10m 2. We preserve the right to changes without further notice L p d () Inlet duct Outlet duct Fan room Inlet duct Outlet duct Fan room

13 Instructions for installation, use and maintenance of IRE The insulated duct fan is fitted with an asynchronus motor of external rotortype with enclosed maintenance-free ballbearings. Single-phase motors are equipped with an approved thermo-contact protector with automatic reset.tri-phase motors are ready-wired with thermo-contact leads. These must be connected over a motorprotector, or if speed control is used, over a thermo-contact relay, fitted as standard in our tri-phase transformers. The thermo-contact breaks the current if the temperature in the motor windings becomes excessive. In single-phase motors the thermo-contact is reset automatically when the temperature in the motor windings falls to the permitted level. In triphase motors, the thermo-contact is reset as follows: Turn off the mains power. Wait until the motor has cooled. Reconnect the mains power. The fan is intended for continuous operation and can be speed-controlled by voltage variation using external equipment. It is not designed for transporting explosive gases, grinding dust, soot, flour or similar. Electrical installation: The fan may only be installed by a qualified electrican. ll IRE fans are supplied fully-wired and ready to fit in a sealed installation unit, which can be placed on four different sides of the duct fan. 1. heck that the voltage, frequency, cycles etc. of the mains supply correspond to the specifcations on the fan s I plate. 2. ll electrical wiring and connections must be carried out in compliance with national safety regulations with regard to HT current. 3. N.. The fan must be connected to ground. Installation and fitting: The fan can be installed in any position. For the maximum temperature of transported air, refer to the diagram of the fan. The fan must be fitted to a duct or fitted with a protective grille if safety class IP 44 is to apply. are and maintenance: The only maintenance required is cleaning. We recommend inspection of the impeller every six months if the fan is operated continuously. efore cleaning: isconnent from the mains and block the mains switch. Wait until the motor and impeller have stopped rotating. are must be taken during dismantling and cleaning so as not to disturb the fan s balance. Strong detergents or cleaning agents must not be used for cleaning the fan. Internal insulation may be wiped clean with a damp cloth. Sharp or rotating tools must not be used as these may damage outer surfaces. In case of breakdown: 1. heck that mains power is reaching the fan. 2. isconnect from the mains and ensure that the impeller is not blocked. 3. heck the thermo-contact according to the description above. If the thermo-contact has activated, the cause of overheating should be determined to prevent the same fault recurring. 4. heck that the capacitor is connected (single-phase, refer to the wiring diagram). 5. If the fault persist, change the capacitor. 6. If these steps do not help, contact your supplier. 7. Should the fan need to be returned to us, the impeller must be cleaned and motor wiring undamaged, and a written description of the fault enclosed.

Roof Fans. web-version

Roof Fans. web-version Roof Fans web-version Contents TKS and TKC 4 TKS 300 5 TKC 300 6 TKS 400 7 TKC 400 8 TKK 9 TKK 300 9 TKK 400 10 page TKK 560 A1 12-13 TKK 560 B1 12-13 TKK 560 B3 12-13 TKK 660 B1 14-15 TKK 660 B3 14-15

More information

Directions for use CK 125 C EC, CK 150 B EC, CK 160 B EC, CK 160 C EC CK 200 B EC, CK 250 B EC, CK 315 B EC, CK 315 C EC ENGLISH VERSION

Directions for use CK 125 C EC, CK 150 B EC, CK 160 B EC, CK 160 C EC CK 200 B EC, CK 250 B EC, CK 315 B EC, CK 315 C EC ENGLISH VERSION Directions for use CK 125 C EC, CK 150 B EC, CK 160 B EC, CK 160 C EC CK 200 B EC, CK 250 B EC, CK 315 B EC, CK 315 C EC ENGLISH VERSION ENGLISH This directions for use contains following products: CK

More information

TKC, TKS, TKV/TKH Roof fans

TKC, TKS, TKV/TKH Roof fans www.ostberg.com TKC, TKS, TKV/TKH Roof fans Contents ROO ANS.......................3 TKC 300 A/B/C...................4 TKC 400 A/B/C...................4 TKS 300 A/B/C...................5 TKS 400 A/B/C...................5

More information

CK, LPK, LPKB. Duct fans with circular connection.

CK, LPK, LPKB. Duct fans with circular connection. CK, LPK, LPKB Duct fans with circular connection 1 www.ostberg.com Contents CK CIRCULAR DUCT FAN............5 CK 100 A/C 230 V/50 Hz........6 CK 125 A/C 230 V/50 Hz........6 CK 150 B/C 230 V/50 Hz........7

More information

IN-LINE RECTANGULAR FANS IRB / IRBS IRB

IN-LINE RECTANGULAR FANS IRB / IRBS IRB IN-LINE RECTANGULAR FANS IRB / IRBS IRB IN-LINE RECTANGULAR FANS IRB / IRBS IRB and IRBS are a compact series of centrifugal type exhaust and supply in-line duct fans for air conditioning systems. They

More information

VORTICENT C E RANGE Centrifugal fans

VORTICENT C E RANGE Centrifugal fans NEW VORTICENT C E RANGE Centrifugal fans Suitable for domestic, commercial and industrial applications: kitchens, bathrooms, offices, laboratories, factories, shops, laundromats, models, restaurants, bars,

More information

In-line rectangular fans. Technical Catalogue

In-line rectangular fans. Technical Catalogue In-line rectangular fans Technical Catalogue Overview IN-LINE RECTANGULAR FANS IRB / IRBS IRB and IRBS are a compact series of centrifugal type exhaust and supply in-line duct fans for air conditioning

More information

Operating Instructions. International English. CCS Dust Extractor

Operating Instructions. International English. CCS Dust Extractor Operating Instructions International English CCS Dust Extractor Electric Cast Saw Dust Removal System Warnings & Safety Rules WARNING!: THIS EQUIPMENT MUST BE EARTHED! Danger!: Possible explosion hazard

More information

IN-LINE DUCT FANS MIXVENT-TD Fan Systems

IN-LINE DUCT FANS MIXVENT-TD Fan Systems IN-LINE DUCT FANS MIXVENT-TD Fan Systems NEW TD-EXTRACTOR KIT (see page 175) MIXVENT TD / MIXVENT TD-T MIXVENT TDx2 ACCESSORIES Description Range Construction The MIXVENT system has been designed to compliment

More information

Device can be connected to pull air directly from ventilated room or air duct system. Not suitable for polluted air or volatile and explosive gases.

Device can be connected to pull air directly from ventilated room or air duct system. Not suitable for polluted air or volatile and explosive gases. VSA 3. ROOF FAS Features Power supply Temperature range 4 sizes; Airflow up to 117 m 3 /h; Horizontal exhaust; Backward-curved impeller; ost-effective. 23V/5Hz/1f. From -4 up to 4/65. Sizes 19 S, 19, 22

More information

GV In Line Circular Duct Fan Circular Ducting High/Low Speed Performance

GV In Line Circular Duct Fan Circular Ducting High/Low Speed Performance GV In Line Circular Duct Fan Circular Ducting High/Low Speed Performance GENERAL VENTILATOR A quality product suitable for general residential application. proprietary made and compact design fan is designed

More information

High efficiency low noise Speed-controllable Integral thermal contacts Can be installed in any position Maintenance-free and reliable

High efficiency low noise Speed-controllable Integral thermal contacts Can be installed in any position Maintenance-free and reliable KD High efficiency low noise Speed-controllable Integral thermal contacts Can be installed in any position Maintenance-free and reliable Electrical accessories S-ET p. 341 The KD series have external rotor

More information

IN-LINE CENTRIFUGAL DUCT FANS VT Series

IN-LINE CENTRIFUGAL DUCT FANS VT Series IN-LINE CENTRIFUGAL DUCT FANS VT Series DESCRIPTION The VT series of circular in-line duct centrifugal fans consists of model variations within nominal model sizes of,,,,, and mm respectively. The VT range

More information

A Series 50HZ. A - Series. Vertical Multistage Centrifugal in-line Pumps AVC/AVI/AVS ISO-9001

A Series 50HZ. A - Series. Vertical Multistage Centrifugal in-line Pumps AVC/AVI/AVS ISO-9001 A - Series A Series ISO-9 AVC/AVI/AVS HZ Evak Pump Technology Corp. No., Zhongshan Rd., Qingshui Township, Taichung County, Taiwan. Tel : +-- Fax: +--9 www.evak-pumps.com Vol. PIAV- A-Series Index Multistage

More information

NEW Acoustic In-Line Fans (ACQ)

NEW Acoustic In-Line Fans (ACQ) NEW Acoustic In-Line Fans (ACQ) Acoustically treated housing, Class O rated, sandwich construction selected for maximum noise absorption Motors protected to IP44 Motor insulation Class B Maximum operating

More information

IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems

IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems MIXVENT TD / MIXVENT TD-T MIXVENT TDx2 ACCESSORIES Description Range Construction The MIXVENT system has been designed to compliment the MIXVENT-TD range

More information

KV sileo 100 M. Circular duct fans. Circular duct fans

KV sileo 100 M. Circular duct fans. Circular duct fans KV sileo 100 M Speed-controllable Integral thermal contacts Can be installed in any position Can be installed outdoors Maintenance-free and reliable Electrical accessories RE p. 20 The K series is designed

More information

LPS IN-LINE CENTRIFUGAL ELECTRIC PUMPS. Your Life, our Quality. Worldwide. 118 Heating & Conditioning

LPS IN-LINE CENTRIFUGAL ELECTRIC PUMPS. Your Life, our Quality. Worldwide. 118 Heating & Conditioning In-Line centrifugal electric pumps with stainless steel hydraulic parts AISI 304. APPLICATIONS Civil/industrial heating plants Systems for moving domestic hot water Cooling and air conditioning plants

More information

HOT WASHER MODEL NO: KING 125 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS1009

HOT WASHER MODEL NO: KING 125 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS1009 HOT WASHER MODEL NO: KING 125 PART NO: 7320170 OPERATION & MAINTENANCE INSTRUCTIONS LS1009 INTRODUCTION Thank you for purchasing this Hot Washer. This machine is a portable, high pressure power washer,

More information

OPERATING AND COMMISSIONING MANUAL

OPERATING AND COMMISSIONING MANUAL OPERATING AND COMMISSIONING MANUAL 2015/03 1 In compliance with the current norms, the machine should be installed only by a technical person qualified for this type of work. During installation, ensure

More information

A Series 50HZ. A - Series. Vertical Multistage Centrifugal in-line Pumps AVC/AVI/AVS ISO-9001

A Series 50HZ. A - Series. Vertical Multistage Centrifugal in-line Pumps AVC/AVI/AVS ISO-9001 A - Series A Series ISO-9 AVC/AVI/AVS HZ Evak Pump Technology Corp. No., Zhongshan Rd., Qingshui Township, Taichung County, Taiwan. Tel : +-- Fax: +--9 www.evak-pumps.com Vol. PIAV- A-Series Index Pump

More information

OPERATING MANUAL PHASE SEQUENCE AND MOTOR ROTATION DIRECTION TESTER TKF-13

OPERATING MANUAL PHASE SEQUENCE AND MOTOR ROTATION DIRECTION TESTER TKF-13 OPERATING MANUAL PHASE SEQUENCE AND MOTOR ROTATION DIRECTION TESTER TKF-13 v1.5 07.07.2011 Table of contents 1. Safety measures... 2 2. Phase spin direction test... 3 3. Motor shaft spin direction (using

More information

ROOF MOUNTED FANS MIXVENT-TH Series Mixed Flow Fans MIXVENT-TH. Roof mounted fans. Flame retardant terminal box. Circular spigot coupling

ROOF MOUNTED FANS MIXVENT-TH Series Mixed Flow Fans MIXVENT-TH. Roof mounted fans. Flame retardant terminal box. Circular spigot coupling MIXVENT-TH ROOF MOUNTED FNS MIXVENT-TH Series Mixed Flow Fans Range of roof mounted mixed flow fans supplied as standard for extract operation. The models 500 and 800 are manufactured from high strength

More information

USER MANUAL. TSK and TSK V.

USER MANUAL. TSK and TSK V. USER MANUAL TSK and TSK V www.sisteven.com Types of roof fan: TSK TSK V 1. Start All fans produced by SISTEVEN, hereinafter the manufacturer, and the full line of accessories, have been manufactured in

More information

Device can only be used indoors. Not suitable for polluted air or volatile and explosive gases. Single phase speed controller.

Device can only be used indoors. Not suitable for polluted air or volatile and explosive gases. Single phase speed controller. VKS VKSA Features Power supply Temperature range 400x200 mm to 1000x500 mm flanges; Airflow up to 9200 m 3 /h; Can be mounted on floors, walls or ceilings; Forward-curved galvanized steel impeller; Cost-effective;

More information

product data sheet FUA (60Hz) FUA-1800/2100/2700/3000/4700

product data sheet FUA (60Hz) FUA-1800/2100/2700/3000/4700 FU (60Hz) FU-1800/2100/2700/3000/4700 The FU is an extraction fan that is specially designed to remove welding and other fumes, dust, oil mist and exhaust gases. The fan is intended and designed for mounting

More information

DUMPER. Data Book 50 Hz

DUMPER. Data Book 50 Hz Data Book 50 Hz CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 202 CURVE SPECIFICATIONS 203 1X 51-S 204 1X 51.5-S 205 2X 51.5-S 206 2X 52.2-S 207 2X 53-S 208 3X

More information

ROOF MOUNTED FANS TH-MIXVENT Series Mixed Flow Fans TH-MIXVENT. Roof mounted fans. Flame retardant terminal box. Circular spigot coupling

ROOF MOUNTED FANS TH-MIXVENT Series Mixed Flow Fans TH-MIXVENT. Roof mounted fans. Flame retardant terminal box. Circular spigot coupling ROOF MOUNTED FNS Series Mixed Flow Fans P P L I T I O N S Workshops ommercial premises Offices Restaurants and cafes Wine cellars asements Range of roof mounted mixed flow fans supplied as standard for

More information

VKAP 100 MD/LD 3.0 Product version Motor power level (M higher power level, L lower power level) Diameter Product name. Guard grille.

VKAP 100 MD/LD 3.0 Product version Motor power level (M higher power level, L lower power level) Diameter Product name. Guard grille. Application Features Power supply Circular duct fans are used in low-to medium-pressure ducted systems. Fans are suitable for air supply or exhaust of residential buildings, warehouses, bathrooms, lavatories,

More information

BELT DRIVEN CABINET FANS CVTT Series

BELT DRIVEN CABINET FANS CVTT Series Range of forward curved belt drive cabinet fans manufactured from galvanised steel sheet, internally lined with melamine thermo-acoustic insulation. ll models incorporate a double inlet low pressure centrifugal

More information

DUMPER. Data Book 50 Hz

DUMPER. Data Book 50 Hz Data Book 50 Hz CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 202 CURVE SPECIFICATIONS 203 1X 51-S 204 1X 51.5-S 205 2X 51.5-S 206 2X 52.2-S 207 2X 53-S 208 3X

More information

product data sheet fua-1800/2100/2700/3000/4700

product data sheet fua-1800/2100/2700/3000/4700 FU (60hz) fua1800/2100/2700/3000/4700 The FU is an extraction fan that is specially designed to remove welding and other fumes, dust, oil mist and exhaust gases. The fan is intended and designed for mounting

More information

A Series. 60 Hz. A - Series. Vertical Multistage Centrifugal in-line Pumps AVC/AVI/AVS ISO-9001

A Series. 60 Hz. A - Series. Vertical Multistage Centrifugal in-line Pumps AVC/AVI/AVS ISO-9001 A - Series A Series ISO-9 AVC/AVI/AVS Hz Evak Pump Technology Corp. No. 55, Zhongshan Rd., Qingshui Dist., Taichung City, Taiwan. Tel : +--55 Fax: +--5559 www.evak-pumps.com Vol. PIAV- A-Series Index Pump

More information

USER S MANUAL. TwinFresh R-50 SINGLE-ROOM REVERSIBLE VENTILATOR

USER S MANUAL. TwinFresh R-50 SINGLE-ROOM REVERSIBLE VENTILATOR USER S MANUAL SINGLE-ROOM REVERSIBLE VENTILATOR 2 CONTENT Introduction Use Delivery set Designation key Main technical parameters Safety requirements Design and operating logic Mounting and set-up Unit

More information

VKAP 100 MD/LD 3.0 Product version Motor power level (M higher power level, L lower power level) Diameter Product name. Guard grille.

VKAP 100 MD/LD 3.0 Product version Motor power level (M higher power level, L lower power level) Diameter Product name. Guard grille. VKAP 3. Features Power supply Temperature range Diameter - 1 mm to 315 mm; Airflow up to 137 m 3 /h; Easily mounted in any position; Backward-curved impeller; Low ambient temperatures; Cost-effective.

More information

Category 1 (zone 0) covers areas, where there is a permanent or long lasting occurrence

Category 1 (zone 0) covers areas, where there is a permanent or long lasting occurrence Explosion proof fans General Systemair explosion proof fans have been developed to be used in effective supply and exhaust air systems allocated to category 2 (zone 1) and category 3 (zone 2) in explosion

More information

DUMPER. Data Book 50 Hz

DUMPER. Data Book 50 Hz Data Book 50 Hz CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY 202 GAMMA 203 CURVE SPECIFICATIONS 204 1X 51-S 205 1X 51.5-S 206 2X 51.5-S 207 2X 52.2-S 208 2X 53-S 209 3X 53.7-S 210 3X

More information

Vent-Axia Sabre Sickle Roof Fans (VSR)

Vent-Axia Sabre Sickle Roof Fans (VSR) Vent-Axia Sabre Sickle Roof Fans (VSR) Features and Benefits High performance roof sickle fan Fully assembled cowl. Optional backdraught shutters and birdguard Moulded from recyclable polymeric material,

More information

AL-RED. Stainless steel centrifugal pumps

AL-RED. Stainless steel centrifugal pumps AL-RED Stainless steel centrifugal pumps AL-RED -4 Pump body: stainless steel AISI 304 Impeller: stainless steel AISI 304 Shaft: stainless steel AISI 431 AL-RED -6 Pump body: stainless steel AISI 316L

More information

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE Roofmaster STEC non-insulated version - Technical Catalogue 3 CONTENTS GENERAL DESCRIPTION Application/specification...4 Features...4

More information

Source Capture Air Purification System

Source Capture Air Purification System Source Capture Air Purification System HA-SCP-G3 Owner s Manual Table of Contents HealthyAir HA-IFM-1111 Filter 1 Important Safety Instructions 2 Technical Specifications 3 Packaging Reference 4 Packing

More information

Series VENTS KSK. Centrifugal kitchen fan in sound-insulated casing with air flow up to 8138 m 3 /h

Series VENTS KSK. Centrifugal kitchen fan in sound-insulated casing with air flow up to 8138 m 3 /h SOUND-INSULATED KITCHEN FAN Series device. The impeller is mounted on the motor shaft and is balanced statically and dynamically. The motor has F class motor winding insulation and ingress protection rating.

More information

Bifurcated Case Axial Fans (BIFA)

Bifurcated Case Axial Fans (BIFA) Bifurcated Case Axial Fans (BIFA) Sizes 250 to 1000 dia Motors protected to IP55 Motor insulation Class F Maximum ambient temperature 200 C Speed controllable via transformer or inverter (when the ambient

More information

MIXVENT-TH Series Mixed Flow Fans

MIXVENT-TH Series Mixed Flow Fans ROOF MOUNTED FNS MIXVENT-TH Series Mixed Flow Fans 0 021682 603075 P P L I T I O N S Range of roof mounted mixed flow fans supplied as standard for extract operation. The models 500 and 800 are manufactured

More information

Sabre Sickle Fan Assisted Roof Cowls (VSR)

Sabre Sickle Fan Assisted Roof Cowls (VSR) Sabre Sickle Fan Assisted Roof Cowls (VSR) Swept impeller with Aerofoil blades, winglets and serrated trailing edge for optimum performance Fully assembled cowl, separate plate axial fan Optional backdraught

More information

CP Centrifugal pumps PERFORMANCE RANGE INSTALLATION AND USE APPLICATION LIMITS PATENTS - TRADE MARKS - MODELS CONSTRUCTION AND SAFETY STANDARDS

CP Centrifugal pumps PERFORMANCE RANGE INSTALLATION AND USE APPLICATION LIMITS PATENTS - TRADE MARKS - MODELS CONSTRUCTION AND SAFETY STANDARDS CP Centrifugal pumps PERFORMANCE RANGE Flow rate up to 900 l/min (54 m³/h) Head up to 74 m APPLICATION LIMITS Manometric suction lift up to 7 m Liquid temperature between -10 C and +90 C Ambient temperature

More information

Oil/Air Cooler Units. Standard series OK-P type. Test procedure certified following EN

Oil/Air Cooler Units. Standard series OK-P type. Test procedure certified following EN COMPLETE OIL / AIR COOLER WITH AXIAL FAN FOR INDUSTRIAL APPLICATIONS. Application These high performance coolers with axial fans are suitable for hydraulic cooling applications. Typical applications include:

More information

GmbH Lufttechnik Dresden USER INFORMATION ROOF FANS SERIES VRV. vertical outlet. Issue 07/02

GmbH Lufttechnik Dresden USER INFORMATION ROOF FANS SERIES VRV. vertical outlet. Issue 07/02 GmbH Lufttechnik Dresden USER INFORMATION ROOF FANS SERIES VRV vertical outlet Issue 07/02 Roof fans made of plastic materials Series VRV with vertical outlet Usable in ventilation engineering of all branches

More information

2CP Twin-impeller pumps

2CP Twin-impeller pumps 2CP Twin-impeller pumps PERFORMANCE RANGE Flow rate up to 450 l/min (27 m³/h) Head up to 112 m APPLICATION LIMITS Manometric suction lift up to 7 m Liquid temperature between -10 C and +90 C (up to +40

More information

CNA-CNB CNA-CNB CENTRIFUGAL FANS STANDARD TEMPERATURES AND EX

CNA-CNB CNA-CNB CENTRIFUGAL FANS STANDARD TEMPERATURES AND EX NA-NB NA-NB ENTRIFUGAL FANS STANDARD TEMPERATURES AND EX PRODUT FATS PRODUT The centrifugal fans type NA and NB are robust and versatile fans of the single-inlet type with backward-curved blades. APPLIATION

More information

ROOFMASTER STEF-HT ROOF FAN

ROOFMASTER STEF-HT ROOF FAN fire safety Air movement Roof Fans ROOFMASTER STEF-HT ROOF FAN» Technical CATALOGuE Contents ROOFMASTER STEF-HT...3 Performance Data...4 Performance Table...5 General description...6 Fan Chart-explanation

More information

Specifications. Applications Ventilation of safety cabinets (STORM 10), scrubbers, fume capture arms, filter housing, etc. (STORM 12, 14, 16).

Specifications. Applications Ventilation of safety cabinets (STORM 10), scrubbers, fume capture arms, filter housing, etc. (STORM 12, 14, 16). Specifications Applications Ventilation of safety cabinets (STORM 10), scrubbers, fume capture arms, filter housing, etc. (STORM 12, 14, 16). Housings: PP* Single block strong high density UV treated and

More information

Sound attenuators. Sound attenuators, Sound attenuating louvres. Sound attenuators. Rectangular sound attenuators DZ-2, DZ-3

Sound attenuators. Sound attenuators, Sound attenuating louvres. Sound attenuators. Rectangular sound attenuators DZ-2, DZ-3 , Sound attenuating louvres Rectangular sound attenuators DZ-2, DZ-3 Application are designed to attenuate noises of fans and air-conditioning devices in ventilation and air-conditioning installations.

More information

BACKWARD CURVE CENTRIFUGAL FANS KABB / KABT Series

BACKWARD CURVE CENTRIFUGAL FANS KABB / KABT Series Cabinet fans manufactured from galvanised steel sheet with double thickness side panels lined with 17 mm thickness of fireproof fibreglass acoustic insulation (M0). Circular duct connection flange on the

More information

AXIAL FAN WITH EXTERNAL ROTOR MOTOR

AXIAL FAN WITH EXTERNAL ROTOR MOTOR XIL FN ITH EXTERNL ROTOR MOTOR 1. YF series axial fans are external rotor motors. These motors have characteristics of compact structure, convenient installation and high efficiency etc. 2. YF series external

More information

The Straight Way. Rectangular Cabinet Fan. Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans

The Straight Way. Rectangular Cabinet Fan. Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans The Straight Way Rectangular Cabinet Fan Systemair India Pvt. Ltd. certifies that the Rectangular

More information

CMRT Series BACKWARD CURVED CENTRIFUGAL FANS. Backward curved centrifugal fans CMRT 80 C

CMRT Series BACKWARD CURVED CENTRIFUGAL FANS. Backward curved centrifugal fans CMRT 80 C BACKWARD CURVED CENTRIFUGAL FANS CMRT Series 80 C Continuous operation Range of single inlet direct drive centrifugal fans designed for continuous extraction of air stream up to 80ºC. Casings are manufactured

More information

PRM-2 PHASE SEQUENCE TESTER PRM-3 PHASE SEQUENCE & MOTOR ROTATION TESTER User s Manual

PRM-2 PHASE SEQUENCE TESTER PRM-3 PHASE SEQUENCE & MOTOR ROTATION TESTER User s Manual PRM-2 PHASE SEQUENCE TESTER PRM-3 PHASE SEQUENCE & MOTOR ROTATION TESTER User s Manual 99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com CONTENTS PRM-2 & PRM-3 1. Warranty...3

More information

- CONTENTS SPECIFICATIONS 200 SELECTION CHARTS 201 PERFORMANCE CHART 2CDX PERFORMANCE CHART 2CDX PERFORMANCE CHART 2CDX

- CONTENTS SPECIFICATIONS 200 SELECTION CHARTS 201 PERFORMANCE CHART 2CDX PERFORMANCE CHART 2CDX PERFORMANCE CHART 2CDX CONTENTS Page - CONTENTS 100 - SPECIFICATIONS 200 SELECTION CHARTS 201 PERFORMANCE CHART 70 202 PERFORMANCE CHART 120 203 PERFORMANCE CHART 200 204 - CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL

More information

Square Mixed Flow Fans (MFQ)

Square Mixed Flow Fans (MFQ) Square Mixed Flow Fans (MFQ) Features and Benefits Motors protected to IP44 Motor insulation Class B Maximum operating temperature +40 C Standard Thermal Overload Protection Sizes 400 to 500 3 phase are

More information

AXICIAT VA. Axial fans. Smoke extraction F200/120 and F400/120. High available pressure

AXICIAT VA. Axial fans. Smoke extraction F200/120 and F400/120. High available pressure Smoke extraction F200/120 and F400/120 A complete range from 1250 to 95000 m 3 /s High available pressure Blade with variable pitch on stop APPLICATION Extraction or introduction of non-loaded air in the

More information

FLÄKTGROUP PM-MOTOR WITH INTEGRATED FC 106 FREQUENCY CONVERTER

FLÄKTGROUP PM-MOTOR WITH INTEGRATED FC 106 FREQUENCY CONVERTER FLÄKTGROUP PM-MOTOR WITH INTEGRATED FC 106 FREQUENCY CONVERTER INSTALLATION AND MAINTENANCE INSTRUCTIONS Risk of electric shock: Motor terminals may still be live if the impeller is rotating, even when

More information

2CP. Twin-impeller pumps PERFORMANCE RANGE INSTALLATION AND USE APPLICATION LIMITS OPTIONALS AVAILABLE ON REQUEST CONSTRUCTION AND SAFETY STANDARDS

2CP. Twin-impeller pumps PERFORMANCE RANGE INSTALLATION AND USE APPLICATION LIMITS OPTIONALS AVAILABLE ON REQUEST CONSTRUCTION AND SAFETY STANDARDS 2CP Twin-impeller pumps PERFORMANCE RANGE Flow rate up to 40 l/min (27 m³/h) Head up to 112 m APPLICATION LIMITS Manometric suction lift up to 7 m Liquid temperature between -10 C and +90 C Ambient temperature

More information

Series VENTS OVK. Low pressure axial fans in the steel casing with the air. for wall mounting.

Series VENTS OVK. Low pressure axial fans in the steel casing with the air. for wall mounting. AXIAL FANS Series VENTS OV Series VENTS OVK Series VENTS Low pressure axial fans in the steel casing with the air capacity up to 11900 m 3 /h for wall mounting. Low pressure axial fans in the steel casing

More information

Technical Information Manual

Technical Information Manual Technical Information Manual Revision n. 4 18 June 2008 MOD. A3000NF 3-PHASE NOTCH FILTER MANUAL REV. 4 NPO: 00120/04:3000N.MUTx/04 CAEN will repair or replace any product within the guarantee period if

More information

Installation, Maintenance and Operation manual 4 Submersible sand fighter pump. Type: SSFP - Series

Installation, Maintenance and Operation manual 4 Submersible sand fighter pump. Type: SSFP - Series Installation, Maintenance and Operation manual 4 Submersible sand fighter pump Type: SSFP - Series Prakash Pump Warranty We guarantee our products, for the period of 24 months from the date of purchase.

More information

NALSRF BELT DRIVE ACOUSTIC SINGLE EXTERNAL ROOF FANS

NALSRF BELT DRIVE ACOUSTIC SINGLE EXTERNAL ROOF FANS NALSRF BELT DRIVE ACOUSTIC SINGLE EXTERNAL ROOF FANS External roof mounted single fan unit manufactured from aluzinc. 7.111 +44 (0) 29 2085 8515 BENEFITS Hard wearing on site External single fan unit manufactured

More information

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401 CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 202 PERFORMANCE CURVE 80 203 PERFORMANCE CURVE 100 204 PERFORMANCE CURVE 120 205 PERFORMANCE CURVE 150 206 - CONSTRUCTIONS

More information

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401 CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 202 PERFORMANCE CURVE 80 203 PERFORMANCE CURVE 100 204 PERFORMANCE CURVE 120 205 PERFORMANCE CURVE 150 206 - CONSTRUCTIONS

More information

V5A TEDDY TEDDY is a registered trademark belonging to A/S Wodschow & Co. SPARE PART AND OPERATION MANUAL

V5A TEDDY TEDDY is a registered trademark belonging to A/S Wodschow & Co. SPARE PART AND OPERATION MANUAL V5A TEDDY TEDDY is a registered trademark belonging to A/S Wodschow & Co. 052017 US SPARE PART AND OPERATION MANUAL 14240 South Lakes Drive Charlotte, NC 28273 800 222-1138 www.varimixer.com mixer@varimixer.com

More information

Diesel Cooker x100. Operating and Maintenance Instructions

Diesel Cooker x100. Operating and Maintenance Instructions Diesel Cooker x100 Operating and Maintenance Instructions Dear Webasto customer, Congratulations for buying the Webasto Diesel Cooker X100. You have purchased a high-quality Webasto product which will

More information

VENTS KSB K2. Series. Inline centrifugal fans in heat- and sound-insulated casing with air flow up to 7000 m 3 /h SOUND-INSULATED FANS

VENTS KSB K2. Series. Inline centrifugal fans in heat- and sound-insulated casing with air flow up to 7000 m 3 /h SOUND-INSULATED FANS SOUND-INSULATED FANS Series Inline centrifugal fans in heat- and sound-insulated casing with air flow up to 7 m 3 /h Purpose KSB fan design allows to use them in supply and exhaust ventilation systems

More information

SIZING OF SOLAR GENERATOR

SIZING OF SOLAR GENERATOR MULTI ISLAND is a water pumping system with power from photovoltaic panels. It is designed for use in water wells, irrigation systems, or the power supply network is not available, or when the user wishes

More information

Sabre Plate Mounted Sickle Fans (VSP)

Sabre Plate Mounted Sickle Fans (VSP) Sabre Plate Mounted Sickle Fans (VSP) Swept impeller with Aerofoil blades, winglets and serrated trailing edge for optimum performance One shot die cast impeller, dynamically balanced for smoother operation

More information

CSXRT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJSXR: Ventilation units with a backward-curved impeller

CSXRT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJSXR: Ventilation units with a backward-curved impeller CSXR CSXRT CJSXR CSXR: Belt-driven single inlet centrifugal fans with shaft outlet and backward-curved impeller CSXRT: Belt-driven single inlet centrifugal fans fitted with electric motors, a set of pulleys

More information

MTD Silent Series MIXED FLOW IN-LINE DUCT FAN

MTD Silent Series MIXED FLOW IN-LINE DUCT FAN MT Silent Series MIX LOW IN-LIN UT N Mixed low In-Line uct an MT Silent Series MT Silent 100/2~200/2 MT Silent 250~315 Low profile Mixed-flow fans with sound- absorbent insulation. xtreme ly quiet. General

More information

RECHARGEABLE PORTABLE EVAPORATIVE COOLER

RECHARGEABLE PORTABLE EVAPORATIVE COOLER RECHARGEABLE PORTABLE EVAPORATIVE COOLER Instruction Manual Part No. COMP369 companionleisure.com.au companionleisure.com.au HOURS TIMER COOLER OSCILLATE SPEED HOURS C C CHARGE POWER PARTS LIST 1. Remote

More information

Powerful centrifugal fans for universal use: The product ranges TEM and REM

Powerful centrifugal fans for universal use: The product ranges TEM and REM Powerful centrifugal fans for universal use: The product ranges TEM and REM The fan ranges TEM and REM offered by Nicotra Gebhardt do present a large fan programme of single inlet centrifugal fans which

More information

Centrifugal pumps. PERFORMANCE RANGE Flow rate up to 900 l/min (54 m³/h) Head up to 76 m

Centrifugal pumps. PERFORMANCE RANGE Flow rate up to 900 l/min (54 m³/h) Head up to 76 m CP Centrifugal pumps Clean water Civil use Agricultural use Industrial use PERFORMANCE RANGE Flow rate up to 9 l/min (5 m³/h) Head up to 76 m APPLICATION LIMITS Manometric suction lift up to 7 m Liquid

More information

valymui. - - Rectangular Flexible connection duct silencer Filter cassette Electrical duct heater LJ/E

valymui. - - Rectangular Flexible connection duct silencer Filter cassette Electrical duct heater LJ/E Rectangular duct fans Rectangular ducts fans for ventilation and air conditioning systems, mounted into a system of rectangular air ducts. Used for the air supply or extract. Not suitable for polluted

More information

IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series

IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series Range of low profile in-line mixed flow duct fans manufactured in tough reinforced plastic (from 16 to 8 models) or with metal casing steel finished in a tough epoxy-polyester paint coating (from 1 to

More information

Vertical multi-stage pumps

Vertical multi-stage pumps MK Vertical multi-stage pumps PERFORMANCE RANGE Flow rate up to 180 l/min (10.8 m³/h) Head up to 103 m APPLICATION LIMITS Manometric suction lift up to 7 m Liquid temperature between -10 C and +40 C Ambient

More information

Device can be connected to pull air directly from ventilated room or air duct system. Not suitable for polluted air or volatile and explosive gases.

Device can be connected to pull air directly from ventilated room or air duct system. Not suitable for polluted air or volatile and explosive gases. VSV VSVI Features Power supply Temperature range Sizes Construction Installation Speed control options 9 sizes; Airflow up to 5300 m 3 /h; Vertical exhaust; Backward-curved plastic or galvanized steel

More information

TEDDY W5A OPERATING INSTRUCTIONS

TEDDY W5A OPERATING INSTRUCTIONS TEDDY W5A US OPERATING INSTRUCTIONS EXPLODED VIEW No... Description... Part No. 1... Control button, l. and r.... AR005-178-TZ005 2... Base... AR005-022-TZ002 2.1... Fuse 5 A, slow, 110V... AR005-418-00001

More information

Axial-flow Fan AFC. Model numbering system AF C / T. Accessories Three phase. Power rate 1.

Axial-flow Fan AFC. Model numbering system AF C / T. Accessories Three phase. Power rate 1. xial-flow Fan FC Construction xial fan designed for installation in a ducted system. Casing of rolled and electro-welded steel sheet, powder coated RL5. Impeller in polypropylene. Casing in acid-proof

More information

CDX CENTRIFUGAL PUMPS EPA

CDX CENTRIFUGAL PUMPS EPA 4 CONTENTS V4 - SPECIFICATIONS Page Features & Applications 00 Typical Exploded View 0 Pump & Motor Specifications 02 Selection Chart / Type key 03 - PERFORMANCE CURVES Performance Curve Specifications

More information

EH -EHsp SERIES 50 Hz

EH -EHsp SERIES 50 Hz PRODUCT CATALOG EH -EHsp SERIES 5 Hz HORIZONTAL MULTISTAGE AND SELF-PRIMING PUMPS franklinwater.eu INDEX STAINLESS STEEL HORIZONTAL MULTISTAGE (EH) AND SELF-PRIMING (EHsp) PUMPS... 2 Family curves...3

More information

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL 301 BEARINGS DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL 301 BEARINGS DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401 CONTENTS Page - SPECIFICATIONS 200 PERFORMANCE RANGE and SELECTION CHART 201 TYPE KEY and CURVE SPECIFICATIONS 202 PERFORMANCE CURVE 80 203 PERFORMANCE CURVE 100 204 PERFORMANCE CURVE 120 205 PERFORMANCE

More information

SELF-PRIMING ELECTRIC PUMPS

SELF-PRIMING ELECTRIC PUMPS Self-priming electric pumps stainless steel. APPLICATIONS Supply of drinking water Domestic pressure boosting Small-scale garden irrigation Emptying reservoirs and swimming pools Moving clean water in

More information

400mm - 630mm diameter Volume flow up to 7.2m 3 /s ASED 42 Static pressures up to 1000 Pa High energy efficiency All casings are hot dipped galvanised Low installed noise levels protection IP55 Overheat

More information

Volt/mA Calibrator. Manual

Volt/mA Calibrator. Manual Volt/mA Calibrator Manual Safety Information To avoid possible electric shock or personal injury: Never apply more than 30V between any two jacks, or between any jack and earth ground. Make sure the battery

More information

Centrifugal performance characteristics with axial flow pattern: RADAX VAR

Centrifugal performance characteristics with axial flow pattern: RADAX VAR High pressure in-line mixed-flow fans RADAX VAR Centrifugal performance characteristics with axial flow pattern: RADAX VAR COMPACT PRESSURE-RESISTANT UNIVERSAL In their compact casing, the RADAX VAR impellers

More information

SDS Enclosed Star-Delta Starter User Guide

SDS Enclosed Star-Delta Starter User Guide SDS Enclosed Star-Delta Starter User Guide (7.5kW~90kW) V2.0.0 PLEASE NOTE: AS STANDARD AND UNLESS OTHERWISE SPECIFIED, THIS PRODUCT IS EQUIPPED WITH A BASIC LOW INTEGRITY EMERGENCY STOP CIRCUIT STOPPING

More information

Eco Mixed Flow (emf) Energy Saver. Terminal Box. Performance. Quality Assurance. Impellers. Accessories. Motors

Eco Mixed Flow (emf) Energy Saver. Terminal Box. Performance. Quality Assurance. Impellers. Accessories. Motors Eco Mixed Flow (emf) High efficiency Mixed Flow Fan with guide vanes Available in sizes 355 to 710mm dia. IP54 Fan rating (duct mounted) Operating temperatures up to 80 C (see technical specification)

More information

TSAT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJTSA: Ventilation units with a forward-curved impeller.

TSAT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJTSA: Ventilation units with a forward-curved impeller. TSA TSAT CJTSA TSA: Single inlet, belt-driven centrifugal fans with shaft outlet and forward-curved impeller. TSAT: Single inlet, belt-driven centrifugal fans fitted with electric motors, a set of pulleys

More information

USER S MANUAL VENTS OV/ OVK/ OV1/ OV1 R/ OVK1/ VKF/ VKOM / OVP

USER S MANUAL VENTS OV/ OVK/ OV1/ OV1 R/ OVK1/ VKF/ VKOM / OVP USER S MANUAL Industrial electric axial fans VENTS OV/ OVK/ OV1/ OV1 R/ OVK1/ / VKOM / OVP 2 CONTENTS Safety requirements 3 Introduction 5 Purpose 5 Delivery set 5 Designation key 5 Technical data 6 Design

More information

BSB SINGLE INLET BELT DRIVEN CENTRIFUGAL FANS WITH BACKWARD CURVED IMPELLERS

BSB SINGLE INLET BELT DRIVEN CENTRIFUGAL FANS WITH BACKWARD CURVED IMPELLERS SINGLE INLET BELT DRIVEN CENTRIFUGAL FANS WITH BACKWARD CURVED IMPELLERS BSB 03.06-01 BSB SINGLE INLET BELT DRIVEN CENTRIFUGAL FANS WITH BACKWARD CURVED IMPELLERS Description Construction Fans are not

More information

MAJOR 2 NCH. Ductable units. High pressure and high capacity ductable units RANGE NCH Y NCH NCH I COADIS COMBI. Motor optional

MAJOR 2 NCH. Ductable units. High pressure and high capacity ductable units RANGE NCH Y NCH NCH I COADIS COMBI. Motor optional Y + U I COADIS COMBI High pressure and high ductable units Motor optional is a non independent air conditioning terminal unit for heating and cooling offices and hotels. With reduced dimensions and designed

More information

IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series

IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series Range of low profile in-line mixed flow duct fans manufactured in tough reinforced plastic (from to models) or with metal casing steel finished in a tough epoxy-polyester paint coating (from to models).

More information

4.2 Component Identification

4.2 Component Identification Digital Control Panels Deep Sea Electronics 5220 4.1 General 4.2 Component Identification 4.3 The YML5220 Controller 4.4 Description of Controls 4.5 Navigation 4.5.1 General Navigation 4.5.2 The Event

More information