Technical Information Manual
|
|
- Annice Holmes
- 6 years ago
- Views:
Transcription
1 Technical Information Manual Revision n June 2008 MOD. A3000NF 3-PHASE NOTCH FILTER MANUAL REV. 4 NPO: 00120/04:3000N.MUTx/04
2 CAEN will repair or replace any product within the guarantee period if the Guarantor declares that the product is defective due to workmanship or materials and has not been caused by mishandling, negligence on behalf of the User, accident or any abnormal conditions or operations. CAEN declines all responsibility for damages or injuries caused by an improper use of the Modules due to negligence on behalf of the User. It is strongly recommended to read thoroughly the CAEN User's Manual before any kind of operation. This product must be installed by qualified personnel; the 3-phase EMC filter Mod. CAEN A3000NF does not support operation in hostile areas (magnetic field). CAEN reserves the right to change partially or entirely the contents of this Manual at any time and without giving any notice. Disposal of the Product The product must never be dumped in the Municipal Waste. Please check your local regulations for disposal of electronics products.
3 TABLE OF CONTENTS 1. A3000NF 3 PHASE NOTCH FILTER FOR A A OVERVIEW TECHNICAL DESCRIPTION REAR PANEL COMPONENTS CHANNEL CHARACTERISTIC TABLE OUT CONNECTOR IN CONNECTOR CHASSIS EARTH FUSES ELECTRICAL SCHEME SAFETY INFORMATION AND INSTALLATION REQUIREMENTS INJURY PRECAUTIONS General Recommendations Caution Grounding Input ratings Live circuits Parts substitutions and modifications INSTALLATION Preparation for use Initial inspection Rack mounting AC source phase power supply cable Cooling Fans MAINTENANCE...13 LIST OF FIGURES FIG. 1.1 A3000NF REAR PANEL...5 FIG. 1.2 BACK PANEL LABEL...5 FIG. 1.3 AC I/O LABEL...6 FIG. 1.4 HARTING FEMALE CONNECTOR...6 FIG. 1.5 HARTING MALE CONNECTOR /04:3000N.MUTx/04 A3000NF_REV4.DOC 13 3
4 FIG. 1.6 EARTH CONNECTOR...7 FIG. 1.7 FUSE HOUSING...8 FIG. 1.8 MOD. A3000NF ELECTRICAL SCHEME...8 FIG. 2.1 AC SOURCE CONNECTION...11 FIG. 2.2 POWER SUPPLY CONNECTOR AND CABLE...13 LIST OF TABLES TABLE 1.1 TECHNICAL SPECIFICATIONS OF THE A3000NF 3 PHASE NOTCH FILTER /04:3000N.MUTx/04 A3000NF_REV4.DOC 13 4
5 1. A3000NF 3 Phase Notch Filter for a A Overview The CAEN Mod. A3486, in order to be CE compliant (CEI EN norm on harmonic current emissions), requires 3-phase EMC filter Mod. CAEN A3000NF on the mains supply cable; this filter does not support operation in hostile areas (magnetic field). 1.2 Technical description The CAEN Mod. A3000NF is a two channel notch filter which must be used with the A Phase 220/400 Vac 48 Vdc converter. I/O connectors are housed on the module rear panel. The Mod. A3000NF can be used also on CAEN Mod. A3484, A3485, A3485A and A3485B 400 Vac 48 Vdc converters; for this purpose it is necessary to install on such modules a Harting connector on the Mains power supply cable (see 2.2.5). 1.3 Rear panel components Fig. 1.1 A3000NF Rear panel Fig. 1.2 Back Panel Label 00120/04:3000N.MUTx/04 A3000NF_REV4.DOC 13 5
6 1.4 Channel Characteristic Table Table 1.1 Technical specifications of the A3000NF 3 Phase Notch Filter Packaging Weight AC input AC output Max. Output Power Max. Input Power Fuses 19"-wide, 3U-high Euro-mechanics rack; Depth: 50 cm. 32 Kg 3-phase 400 V ±10% / 50 Hz (see label below) 3-phase 400 V / 50 Hz (see label below) 5000 W per section 5000 W per section OMEGA type 10X38 8A 600V FF (3 per channel) Fig. 1.3 AC I/O Label 1.5 OUT Connector Fig. 1.4 Harting female connector Type: Harting ; Female insert, Han Q 7/0 Series Han Q; Loading Pin: Pin: Phase: 1, 2 R 3, 4 S 5, 6 T 7 n.c /04:3000N.MUTx/04 A3000NF_REV4.DOC 13 6
7 1.6 IN Connector Fig. 1.5 Harting male connector Type: Harting ; Male insert, Han Q 7/0 Series Han Q; Loading Pin Pin: Phase: 1, 2 R 3, 4 S 5, 6 T 7 n.c. 1.7 Chassis EARTH Fig. 1.6 Earth connector This section provides the Earth auxiliary reference and includes: 1 Earth RADIALL R type connector WARNING: ALTHOUGH THE CHASSIS IS ALREADY INTERNALLY CONNECTED TO PROTECTION EARTH PROVIDED BY MAINS POWER SUPPLY PLUG, CAEN STRONGLY ADVICES TO CONNECT THIS TERMINAL TO A GOOD EARTH WITH A LOW IMPEDANCE CABLE PATH, IN ORDER TO IMPROVE EMI SHIELDING AND SAFETY. THIS TERMINAL IS IN ITS TURN INTERNALLY CONNECTED TO PROTECTION EARTH /04:3000N.MUTx/04 A3000NF_REV4.DOC 13 7
8 1.8 Fuses Fig. 1.7 Fuse housing Type: OMEGA type 10X38 8A 600V FF Fuses per channel (one per phase) 1.9 Electrical scheme Fig. 1.8 Mod. A3000NF Electrical scheme 00120/04:3000N.MUTx/04 A3000NF_REV4.DOC 13 8
9 2. Safety information and installation requirements 2.1 Injury Precautions Review the following precautions to avoid injury and prevent damage to this product or any products connected to it. To avoid potential hazards, use the product only as specified. Only qualified personnel should perform service procedures General Recommendations The A3000NF is provided with front panel fixing holes for 19" rack-mounting and will occupy 3U of rack space. Rear support should be provided when fitted in a 19" rack. The A3000NF is a heavy unit (32kg) and should be regarded as a two-man lift. Take suitable precautions when lifting. When rack-mounting the unit needs natural convection of air over the case and an unrestricted air flow through the unit. The A3000NF will operate as a free-standing unit without requiring any special cooling arrangement, but should not be allowed to be accidentally or deliberately covered over in any way. Do not operate the unit with the top cover removed as this exposes hazardous voltages. WARNING: THE A3000NF ACTUALLY OBSTRUCTS THE VERTICAL AIR FLOW THROUGH THE RACK! Caution The following safety precaution must be observed during all phases of operation, service and repair of this equipment. Failure to comply with the safety precautions or warnings in this document violates safety standards of design, manufacture and intended use of this equipment and may impair the built-in protections within. CAEN shall not be liable for user s failure to comply with these requirements. To avoid electric shock or fire hazard, do not apply a voltage to a load that is outside the range specified for that load. To avoid electric shock or fire hazard, do not operate this product with covers or panels removed. Do Not Operate Without Covers. To avoid electric shock or fire hazard, do not operate this product with covers or panels removed. Do Not Operate in Wet/Damp Conditions. To avoid electric shock, do not operate this product in wet or damp conditions. Do Not Operate in an Explosive Atmosphere. To avoid injury or fire hazard, do not operate this product in an explosive atmosphere. Do Not Operate With Suspected Failures. If you suspect there is damage to this product, have it inspected by qualified service personnel. WARNING: ALL ENCLOSED ELECTRICAL/ELECTRONIC EQUIPMENT SHALL BE PROVIDED WITH A MEANS FOR DISCONNECTING IT FROM EACH 00120/04:3000N.MUTx/04 A3000NF_REV4.DOC 13 9
10 EXTERNAL OR INTERNAL OPERATING ENERGY SOURCE. THIS DISCONNECTING MEANS SHALL DISCONNECT ALL CURRENT CARRYING CONDUCTORS. WARNING: DO NOT TOP LOAD WARNING: IN ORDER TO PREVENT RISK OF ELECTRIC SHOCK OR FIRE HAZARD DUE TO OVERHEATING, ENSURE THAT THE UNIT S VENTILATION OPENINGS ARE NOT OBSTRUCTED Grounding This product is a Safety Class 1 instrument. To minimize shock hazard, the instrument chassis must be connected to an electrical ground. The instrument must be connected to the AC power supply mains through a three conductor power cable, with the ground wire firmly connected to an electrical ground (safety ground) at the power outlet. For instruments designed to be hard-wired to the supply mains, the protective earth terminal must be connected to the safety electrical ground before another connection is made. Any interruption of the protective ground conductor or disconnection of the protective earth terminal will cause a potential shock hazard that might cause personal injury. WARNING: DUE TO THE HIGH LEAKAGE CURRENT, REMEMBER TO CONNECT ALSO THE CHASSIS EARTH TERMINAL (SEE 1.7) TO A GOOD EARTH WITH A LOW IMPEDANCE CABLE PATH, IN ORDER TO IMPROVE SAFETY; SUCH TERMINAL IS IN ITS TURN INTERNALLY CONNECTED TO PROTECTION EARTH Input ratings Do not use AC supply, which exceeds the input voltage and frequency rating of this instrument. For input voltage and frequency rating of the module see 1.4. For safety reasons, the mains supply voltage fluctuations should not exceed above voltage range /04:3000N.MUTx/04 A3000NF_REV4.DOC 13 10
11 2.1.5 Live circuits Operating personnel must not remove the instrument cover. No internal adjustment or component replacement is allowed by non-caen personnel. Never replace components with power cable connected. To avoid injuries, always disconnect power, discharge circuits and remove external voltage source before touching components (wait 15 min at least) Parts substitutions and modifications Parts substitutions and modifications are allowed by authorized CAEN service personnel only. 2.2 Installation This Chapter contains instructions for initial inspection, preparation for use and repackaging for shipment Preparation for use In order to be operational the unit must be connected to an appropriate AC source. The AC source voltage should be within the unit specification. The A3000NF shall be connected to the AC source in the following way. Fig. 2.1 AC source connection Initial inspection Prior to shipment this unit was inspected and found free of mechanical or electrical defects. Upon unpacking of the unit, inspect for any damage, which may have occurred in transit. The inspection should confirm that there is no exterior damage to the unit such as broken knobs or connectors and that the front panel and meters face are not scratched or cracked. Keep all packing material until the inspection has been completed. If damage is detected, file a claim with carrier immediately and notify CAEN service Rack mounting The Mod. A3000NF is an equipment for BUILDING-IN: it must be installed in a 19 equipment rack and operated with its upper grid unloaded. Use the front panel rack-mount brackets to install the unit in the rack. This product must be installed by qualified personnel; EMC filter Mod. CAEN A3000NF does not support operation in hostile areas (magnetic field) /04:3000N.MUTx/04 A3000NF_REV4.DOC 13 11
12 WARNING: IN ORDER TO PROVIDE PROPER AIR FLOW, REMEMBER TO LEAVE A ~1 (2.54cm) AT LEAST FREE SPACE ABOVE THE MODULE S UPPER PANEL, WHEN MOUNTED IN THE RACK AC source The Mod. A3000NF ACsource is as follows: The input voltage range and current required is specified in 1.4. Ensure that under heavy load, the AC voltage supplied to the unit does not fall below the specifications described in phase power supply cable The power supply cable to be connected to the IN connector (see 1.6) is configured as follows (see also figure): EARTH : green-yellow cable L1: black cables N 1 & N 2 L2: black cables N 3 & N 4 L3: black cables N 5 & N 6 Connector type: Harting Hood: Harting Contacts: Harting Coding pin Female: Harting Cable: LTZE-Superfelx PLUS-N-PUR suitable to 15A@400V 00120/04:3000N.MUTx/04 A3000NF_REV4.DOC 13 12
13 The Protective Earth Ground must be connected before applying AC Power to the unit Fig. 2.2 Power supply connector and cable Cooling Fans WARNING: INTERNAL FANS ARE POWERED ONLY BY THE LEFT TRIPHASE INPUT, THEREFORE FOR COOLING PURPOSES, IT IS IMPORTANT THAT, WHENEVER ONLY ONE CHANNEL OF THE A3000NF IS USED, THAT HAS TO BE THE LEFTMOST (FROM REAR PANEL VIEW, SEE 1.3). 2.3 Maintenance No routine maintenance of the unit is required except for periodic cleaning. To clean, disconnect the unit from the AC supply and allow 15 minutes for discharging. The metal surfaces should be cleaned using a damp soft cloth containing a mild solution of detergent and water. Use low pressure compressed air to blow dust from the unit /04:3000N.MUTx/04 A3000NF_REV4.DOC 13 13
Switching DC Power Supply
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Model 1693, 1694 Switching DC Power Supply INSTRUCTION MANUAL 1 Safety Summary
More informationRS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to
RS-3 PRO RS-1007 PRO CAT IV Analog Clamp meter Series Users Manual For detailed specifications and ordering info go to www.testequipmentdepot.com RS-3 PRO RS-1007 PRO CAT IV Analog Clampmeter Series English
More information99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Instruction Manual. Model 1672 Triple Output Power Supply
99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com Instruction Manual Model 1672 Triple Output Power Supply Contents Section Description Page No. CONTENTS 1 1 TEST INSTRUMENT
More informationTriple Output Power Supply
Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 TestEquipmentDepot.com Model 1672, 1673 Triple Output Power Supply INSTRUCTION MANUAL 1 Safety Summary The following safety precautions
More information362 Clamp Meter. Users Manual
362 Clamp Meter Users Manual PN 3622678 August 2010, Rev. 1, 4/13 2010, 2013 Fluke Corporation. All rights reserved. Printed in China. Specifications are subject to change without notice. All product names
More information99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Instruction Manual. Model 2831D 4 ½ Digit True RMS Digital Multimeter
99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com Instruction Manual Model 2831D 4 ½ Digit True RMS Digital Multimeter 1 1. PRODUCT DESCRIPTION 1-1. Introduction Thank you
More information190M. Medical ScopeMeter. Safety Information
190M Medical ScopeMeter PN 4202934 June 2012, Rev. 1 2012 Fluke Corporation. All rights reserved. Printed in Romania. All product names are trademarks of their respective companies. WX Warning To prevent
More informationPY-11 Voltage & Continuity Tester
PY-11 Voltage & Continuity Tester Users Manual PY-11 Voltage & Continuity Tester English Users Manual May 2010, Rev.1 2010 Amprobe Test Tools. All rights reserved. Printed in China Limited Warranty and
More informationModel 1672, 1673 Triple Output Power Supply
Model 1672, 1673 Triple Output Power Supply INSTRUCTION MANUAL 1 Safety Summary The following safety precautions apply to both operating and maintenance personnel and must be observed during all phases
More informationINSTRUCTION MANUAL FOR THE CLINICAL 50 CENTRIFUGE
INSTRUCTION MANUAL FOR THE CLINICAL 50 CENTRIFUGE 82013-800 January 2006 INDEX PAGE 1. General Information... 2 1.1 Description... 2 1.2 Safety precautions to be observed before operating the centrifuge...
More informationVol-Con XL (61-086) Voltage/Continuity Tester and Vol-Test (61-085) Voltage Tester Instruction Manual WARNING
Vol-Con XL (61-086) Voltage/Continuity Tester and Vol-Test (61-085) Voltage Tester Instruction Manual WARNING #61-085 #61-086 Read First: Safety Information This tester complies with UL3111-1, Cat III-600
More information& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL
72-6850 & 72-6852 HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL Table of Contents Introduction 2 Specification 2 Safety 4 EMC 5 Installation 6 Connections 6 Operation 7 Maintenance and Repair 8 www.tenma.com
More informationTriple Output High Resolution Power Supply. User Manual
1320 Triple Output High Resolution Power Supply User Manual Safety Summary The following safety precautions apply to both operating and maintenance personnel and must be observed during all phases of operation,
More informationModel NTX7 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006
B R A N D Model NTX7 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006 For Sales, Support and Service phone: 407-331-4793 fax: 407-331-4708 website: www.xenotronix.com email: information@xenotronix.com
More informationMODEL A96 SERIES. 130Vdc Switchmode Utility Rectifier / Battery Charger. Used with LaMarche Power Cage ECN/DATE
MODEL A96 SERIES 130Vdc Switchmode Utility Rectifier / Battery Charger Used with LaMarche Power Cage CPN112138 ECN/DATE ISSUE DATE: ECN 17010-12/05 106 BRADROCK DRIVE DES PLAINES, IL. 60018-1967 (847)
More informationBT508/BT510/BT520/BT521 Battery Analyzer Safety Sheet
BT508/BT510/BT520/BT521 Battery Analyzer Safety Sheet Go to www.fluke.com to register your product, download manuals, and find more information. A Warning identifies conditions and procedures that are
More informationKSZ 10B Current Probe Calibrator. Instruction Manual
KSZ 10B Current Probe Calibrator Instruction Manual Copyright 2011 PMK GmbH All rights reserved. Information in this publication supersedes that in all previously published material. Specifications are
More informationUser s Manual Power Supply. IM E 2nd Edition. Yokogawa Electric Corporation
User s Manual 701934 Power Supply Yokogawa Electric Corporation 2nd Edition Foreword Revisions Thank you for purchasing the 701934 Power Supply. This user's manual contains useful information about the
More informationOBAE, OBAEXU, ON BOARD Battery Chargers
C O R P O R A T IO N O P E R A T I N G I N S T R U C T I O N S OBAE, OBAEXU, ON BOARD Battery Chargers INTRODUCTION: The OBAE line of chargers are designed for the permanent installation on battery powered
More informationMod: KLD6-12/35XLAS-N
12/2011 Mod: KLD6-12/35XLAS-N Production code: 1914070 INSTRUCTION MANUAL LOGIC LINE PLUS HOOD Reseller Stamp for Warranty Dear customer, Above all, thank you for choosing our product and we would like
More informationPhotovoltaic Module User Manual
Photovoltaic Module User Manual Index of Contents: Overview... 1 Applicable Products... 1 Unpacking... 2 Preparation before Installation... 3 Installation and operation... 3 Wiring and Connection... 5
More informationOPERATING INSTRUCTIONS
OPERATING INSTRUCTIONS A.W. Sperry Instruments Inc. AC SNAP-AROUND WITH DC VOLT RANGE MODELS TD-2608 & TD-2608A 1) FEATURES UL Listed Five Functions, 12 Ranges. Tear drop shaped jaws for ease of use in
More informationRT Series Step Down Transformer for RT Series UPS 6-10kVA UL Input Vac Output Vac User Guide
RT Series Step Down Transformer for RT Series UPS 6-10kVA UL Input 208-240 Vac Output 208-120 Vac User Guide UNLESS SPECIFICALLY AGREED TO IN WRITING, SELLER (A) MAKES NO WARRANTY AS TO THE ACCURACY, SUFFICIENCY
More informationDC POWER SUPPLY ALIMENTATION C.C.
DC POWER SUPPLY ALIMENTATION C.C. ISO-TECH IPS 303A 201-3424 ISO-TECH IPS 601A 201-3446 SAFETY TERMS AND SYMBOLS These terms may appear in this manual or on the product: WARNING. Warning statements identify
More informationPHANTOM (PH10 and PH12) COMMERCIAL AND INDUSTRIAL SERIES
Document No: ICM-IOM Date: 0411 PHANTOM (PH10 and PH12) COMMERCIAL AND INDUSTRIAL SERIES Installation, Operation and Maintenance Manual Please read and save these instructions. Read carefully before attempting
More informationREFERENCE MANUAL FORM: MX-TRM-E REL REV MTE
Matrix APAX 380V-415V 50Hz TECHNICAL REFERENCE MANUAL FORM: MX-TRM-E REL. September 2014 REV. 002 2014 MTE Corporation WARNING High Voltage! Only a qualified electrician can carry out the electrical installation
More informationRental Industry Safety Tester Safe Check 5s
Rental Industry Safety Tester Safe Check 5s Feb 2006 2006 Clare Instruments Inc. Issue 2.0 Firmware Version : 1.2a Limited Warranty & Limitation of Liability Clare Instruments Inc, guarantees this product
More informationLS200 Series Instruction Manual
LS200 Series Instruction Manual BEFORE USING THE POWER SUPPLY UNIT Pay attention to all warnings and cautions before using the unit. Incorrect usage may lead to an electrical shock, damage to the unit
More informationMPS14 Rack Mount Power Supply
MPS14 Rack Mount Power Supply USER GUIDE Publication AP3898 Limited One Year Warranty This product has been manufactured in the UK by ALLEN & HEATH and is warranted to be free from defects in materials
More informationTIC 300 PRO. Users Manual Mode d emploi Bedienungshandbuch Manual d uso Manual de uso. Non Contact AC Voltage Detector. High Energy Tic Tracer
TIC 300 PRO High Energy Tic Tracer Non Contact AC Voltage Detector Users Manual Mode d emploi Bedienungshandbuch Manual d uso Manual de uso TIC 300 PRO High Energy Tic Tracer Non Contact AC Voltage Detector
More informationMaxLite LED UTILITY WRAP FIXTURES
General Safety Information To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards read all warnings and instructions
More information5 IN 1 JUMP START OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: JS5IN1 PART NO: LS0810
5 IN 1 JUMP START MODEL NO: JS5IN1 PART NO: 6240005 OPERATION & MAINTENANCE INSTRUCTIONS LS0810 INTRODUCTION Thank you for purchasing this CLARKE product. Before attempting to use this product, please
More informationLINE CONDITIONERS USER'S GUIDE
LINE CONDITIONERS USER'S GUIDE PE 1411/10 (9415 014 11 101) PE 1412/10 (9415 014 12 101) PE 1413/10 (9415 014 13 101) PE 1411/15 (9415 014 11 151) PE 1412/15 (9415 014 12 151) PE 1413/15 (9415 014 13 151)
More informationPD-20 HIGH VOLTAGE PROBE INSTRUCTION MANUAL
PD-20 HIGH VOLTAGE PROBE INSTRUCTION MANUAL Index 1. Safety precaution... 2. Specifications... 3. Operation... 4. Warning... 5. Cleaning... 6. Rated environmental conditions... 7. Observe the international
More informationKSZ 100B Current Probe Calibrator. Instruction Manual
KSZ 100B Current Probe Calibrator Instruction Manual 2 Copyright 2011 PMK GmbH All rights reserved. Information in this publication supersedes that in all previously published material. Specifications
More informationPRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to
PRM-4 Phase Sequence and Motor Rotation Tester Users Manual For detailed specifications and ordering info go to www.testequipmentdepot.com PRM-4 Phase Sequence and Motor Rotation Tester English Users Manual
More informationInstruction Manual. Labnet Spectrafuge 16M Microcentrifuge
Instruction Manual Labnet Spectrafuge 16M Microcentrifuge Labnet International PO Box 841 Woodbridge, NJ 07095 Phone: 732 417-0700 Fax: 732 417-1750 email: labnet@labnetlink.com Safety Precautions NEVER
More informationModel Fixed Rack-Mount Kit
Model 4299-7 Fixed Rack-Mount Kit Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 tek.com/keithley Assembly and Mounting Instructions Introduction This document contains the
More informationOBE, OBEXU, ON BOARD Battery Chargers
C O R P O R A T IO N O P E R A T I N G I N S T R U C T I O N S OBE, OBEXU, ON BOARD Battery Chargers INTRODUCTION: These chargers are designed for the permanent installation on battery powered vehicles
More informationModel HPX60 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006
B R A N D Model HPX60 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006 For Sales, Support and Service phone: 407-331-4793 fax: 407-331-4708 website: www.xenotronix.com email: information@xenotronix.com
More informationc-go 24V/6A 24V/8A 24V/12A
c-go 24V/6A 24V/8A 24V/12A Battery charger GB Instruction manual 1 Index 1. Product description... 2 2. Safety advices... 3 3. Quick start guide... 4 4. Operation... 4 5. Problem solving... 6 6. Specifications...
More informationModel 1693, 1694 Switching DC Power Supply
Model 1693, 1694 Switching DC Power Supply INSTRUCTION MANUAL 1 Safety Summary The following safety precautions apply to both operating and maintenance personnel and must be observed during all phases
More information362 Clamp Meter. Users Manual
362 Clamp Meter Users Manual PN 3622678 August 2010 2010 Fluke Corporation. All rights reserved. Printed in China. Specifications are subject to change without notice. All product names are trademarks
More informationUser s Manual Power Supply IM E. 5th Edition
User s Manual 700938 Power Supply 5th Edition Thank you for purchasing the 700938 Power Supply. This user s manual contains useful information about the instrument s functions and operating procedures
More informationCalibrator Capabilities Function Range Resolution Measure V dc 28 V 1 mv Measure ma dc Source ma dc
707 Loop Calibrator Instruction Sheet Introduction The Fluke 707 Loop Calibrator (hereafter, the Calibrator) is a compact sourcing and measuring tool. The Calibrator tests current loops of 0-20 ma or 4-20
More informationMODEL A97 SERIES. Switchmode Utility Rectifier/Battery Charger ECN/DATE
MODEL A97 SERIES Switchmode Utility Rectifier/Battery Charger CPN108172 ISSUE DATE: 16071 7/03 ECN/DATE 106 BRADROCK DRIVE DES PLAINES, IL. 60018-1967 (847) 299-1188 FAX: (847)299-3061 Page 1 of 7 INSTRUCTION
More information1587 FC/1587/1577. Insulation Multimeter. Safety Information. Warnings
1587 FC/1587/1577 Insulation Multimeter Safety Information Go to www.fluke.com to register your Product and find more information. A Warning identifies conditions and procedures that are dangerous to the
More informationBT403. A Geno Technology, Inc. (USA) brand name. BT-300 Power Supply. Cat. No. BT
BT403 A Geno Technology, Inc. (USA) brand name BT-300 Power Supply Cat. No. BT403 1-800-628-7730 1-314-991-6034 info@btlabsystems.com WARNING... 3 SAFETY INFORMATION... 3 ENVIRONMENTAL CONDITIONS... 4
More informationP90L-ISO6MB & ISO10MB
P90L-ISO6MB & ISO10MB for 6kVA, 10kVA Models User & Installation Manual www.xpcc.com 2014. All rights reserved. (Rev 9/23/14) Table of Contents Important Safety Instructions...3 An Important Notice...3
More informationCX-SERIES ADVANCED BATTERY CHARGER
CX-SERIES ADVANCED BATTERY CHARGER Table of Content 1. IMPORTANT SAFETY INFORMATION... 2 1-1 General Safety Precautions... 2 1-2 Battery Precautions... 2 2. FEATURES... 3 2-1 Battery Charging Curve...
More information233 True-rms Remote Display Digital Multimeter Safety Information
233 True-rms Remote Display Digital Multimeter Safety Information Go to www.fluke.com to register your product and find more information. A Warning identifies conditions and procedures that are dangerous
More informationEVS RP6020. Instruction Manual
Instruction Manual TDK Lambda BEFORE USING THE PRODUCT Be sure to read this instruction manual thoroughly before using this product. Pay attention to all cautions and warnings before using this product.
More information365 Detachable Jaw True-rms Clamp Meter
365 Detachable Jaw True-rms Clamp Meter Users Manual PN 3622684 August 2010 2010 Fluke Corporation. All rights reserved. Printed in China. Specifications are subject to change without notice. All product
More informationUsers Manual. Phase Rotation Indicator
9040 Phase Rotation Indicator Users Manual PN 2438546 April 2005, Rev.2, 5/11 2005-2011 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are
More informationc-go 12V/10A 12V/20A Power supply and battery charger Instruction manual
c-go 12V/10A 12V/20A Power supply and battery charger GB Instruction manual 1 Index 1. Product description... 2 2. Safety advices... 3 3. Mounting and installation... 4 4. Operation... 5 5. Problem solving...
More information373 Clamp Meter. Users Manual
373 Clamp Meter Users Manual PN 3612805 July 2010 2010 Fluke Corporation. All rights reserved. Printed in Taiwan. Specifications are subject to change without notice. All product names are trademarks of
More informationSPECTRA ENGINEERING PTY LTD. MXPS15 Series Technical Manual
SPECTRA ENGINEERING PTY LTD MXPS15 Series Technical Manual MXPS15 Series Spectra Engineering Pty Ltd ABN 65 057 696 438 9 Trade Road Malaga Western Australia 6090 Tel: +61-8-92482755 Fax: +61-8-92482756
More informationMatrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL
Matrix APAX 380V-415V 50Hz TECHNICAL REFERENCE MANUAL WARNING High Voltage! Only a qualified electrician can carry out the electrical installation of this filter. Quick Reference ❶ Performance Data Pages
More informationPURE SINE WAVE DC TO AC POWER INVERTER
PURE SINE WAVE DC TO AC POWER INVERTER 60S-12A / 60S-24A 60S-12E / 60S-24E 100S-12A / 100S-24A 100S-12E / 100S-24E 150S-12A / 150S-24A 150S-12E / 150S-24E Instruction manual SINE WAVE INVERTER Please read
More informationOPERATING MANUAL PHASE SEQUENCE AND MOTOR ROTATION DIRECTION TESTER TKF-13
OPERATING MANUAL PHASE SEQUENCE AND MOTOR ROTATION DIRECTION TESTER TKF-13 v1.5 07.07.2011 Table of contents 1. Safety measures... 2 2. Phase spin direction test... 3 3. Motor shaft spin direction (using
More informationSnapshot LX5 USER MANUAL. OK on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle
LX5 Snapshot OK on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle USER MANUAL Chauvet, 5200 NW 108th Avenue, Sunrise, FL 33351 U.S.A.
More informationMPA Chassis for Multi-Probe Magnetic Transducers
DESCRIPTION: TYPICAL APPLICATIONS: The MPA chassis is utilized for multi-probe SENIS Magnetic Field-to-Voltage Transducer system with any of SENIS Hall Probes. Characterization and quality control of permanent
More informationEVOS M5000 Imaging System
EVOS M5000 Imaging System Pub. No. MAN0017783 Doc. Part No. 710208 Rev. A.0 Note: For safety and biohazard guidelines, see the Safety appendix in the EVOS M5000 Imaging System User Guide (Pub. No. MAN0017563).
More information5.2 PRE-OPERATION PROCEDURE WARRANTY
4/02 Form #314 OPERATING INSTRUCTIONS MODELS DM-210A, 220A, 230A DIGITAL MULTIMETER PLEASE READ THESE OPERATING INSTRUCTIONS CAREFULLY Misuse and or abuse of these instruments cannot be prevented by any
More informationABOT4001 REV1 BATTERY POWERED CRIMP TOOL
Figure 1 Description The ABOT4001 rev1 is a handheld Battery Powered Crimp tool. It uses dies engineered to meet the requirements of the AS22520/40-01 and is intended to crimp insulated terminals, splices,
More informationHS-1000 Fast Low Noise High Voltage Switch
HS-1000 Fast Low Noise High Voltage Switch HS-1000_User_Manual_1_4doc 18. January 2018 Data Sheet & User Manual Rev. 1.4 Applications: Ion Pulsing / Electrode Switching Piezo-Driver Features: fast and
More informationEXHAUST HOODS HNPD, HNPA, HPPD, HFPD, HNCD, HNCA, HPCD, HFCD, HKCD, HNPDC. Installation, Operation and Maintenance Manual
EXHAUST HOODS HNPD, HNPA, HPPD, HFPD, HNCD, HNCA, HPCD, HFCD, HKCD, HNPDC Installation, Operation and Maintenance Manual VALID FROM 2016 Introduction Novameta exhaust hoods are designed to fulfill the
More informationDeclaration of Conformity
We Declaration of Conformity GOOD WILL INSTRUMENT CO., LTD. No. 7-1, Jhongsing Rd, Tucheng City, Taipei County 236, Taiwan GOOD WILL INSTRUMENT (SUZHOU) CO., LTD. No.69 Lushan Road, Suzhou New District
More informationGP-1000 Inverter. Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4 Tel: Fax:
Go Power! Manual GP-1000 Inverter Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4 Tel: 866-247-6527 Fax: 866-607-6527 Email: info@gpelectric.com Table of Contents 1. INTRODUCTION 3 2. SPECIFICATIONS
More informationRP Instruction Manual
Instruction Manual TDK Lambda BEFORE USING THE PRODUCT Be sure to read this instruction manual thoroughly before using this product. Pay attention to all cautions and warnings before using this product.
More informationCONTENT 1 PICTURE GENERAL... 3
IP67 CONTENT 1 PICTURE... 3 1.1 GENERAL... 3 2 DIMENSIONS... 4 2.1 SYMBOLS... 5 2.2 PROTECTION FROM ELECTRIC SHOCK... 6 2.3 PROTECTIONS FROM FIRE AND BURNS... 6 2.4 PROTECTION FROM INJURY... 7 2.5 DISPOSING
More information1662/1663/1664 FC. Electrical Installation Tester. Safety Information. Warnings
1662/1663/1664 FC Electrical Installation Tester Safety Information Go to www.fluke.com to register your Product and find more information. A Warning identifies conditions and procedures that are dangerous
More informationMULTIVOLTAGE PORTABLE BATTERY CHARGER MVM
_ M MULTIVOLTAGE PORTABLE BATTERY CHARGER MVM User's MANUAL Code: MVM Version: 01-BF Date: OCT 2005 Page 1/10 _ 1. INTRODUCTION Before starting to use your Energic plus MVM battery charger, please take
More informationLED Twister II. User manual UK Version 1.0
LED Twister II User manual 152.624UK Version 1.0 LED DUOPLEX: For indoor use only CAUTION! Please read this manual carefully before operating! Pay special attention to Sections 3 & 5 of this document.
More informationContents. Introduction Inspection Notes on Safety Precautions. Chapter 1 Overview Product Overview Names of Parts 2
INSTRUCTION MANUAL Contents Introduction Inspection Notes on Safety Precautions i i ii vii Chapter 1 Overview 1 1.1 Product Overview 1 1.2 Names of Parts 2 Chapter 2 Specifications 5 2.1 Product Specifications
More informationKEEP FOR FUTURE REFERENCE POWER TRANSFORMER READ ALL INSTRUCTIONS AND WARNINGS BEFORE USING THIS PRODUCT
KEEP FOR FUTURE REFERENCE P.O. Box 368 908 West Main Laurel, MT USA 59044 phone 800-548-7341 phone 406-628-8231 fax 406-628-8354 INSTRUCTIONS International Version MODEL NUMBER: EO6VA POWER TRANSFORMER
More informationWINDGUARD BELT DRIVE (BD) INDUSTRIAL SERIES
Document No: BD-IOM Date: 01/13/16 WINDGUARD BELT DRIVE (BD) INDUSTRIAL SERIES Installation, Operation and Maintenance Manual Please read and save these instructions. Read carefully before attempting to
More informationINSTRUCTION SHEET FOR SIGNALMASTER MODELS SM518A AND SM428A
2561263C REV. C 407 Printed in U.S.A. INSTRUCTION SHEET FOR SIGNALMASTER MODELS SM518A AND SM428A SAFETY MESSAGE TO INSTALLERS People s lives depend on your safe installation of our products. It is important
More informationOPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2
OPERATING AND MAINTENANCE MANUAL Product: Type: Primary Current Injection Test Set 750ADM mk2 750ADM-H mk2 DESIGNED AND MANUFACTURED BY: T & R Test Equipment Limited 15-16 Woodbridge Meadows, Guildford,
More informationPHANTOM (PH10 and PH12) COMMERCIAL AND INDUSTRIAL SERIES
Document No: ICM-IOM Date: 1015 PHANTOM (PH10 and PH12) COMMERCIAL AND INDUSTRIAL SERIES Installation, Operation and Maintenance Manual Please read and save these instructions. Read carefully before attempting
More informationME310B BATTERY POWERED CRIMP TOOL
Description The ME310B Battery Powered Crimp Tool is a hand held, self contained crimp tool intended to crimp machined contacts onto copper and aluminum cable. KEEP THIS MANUAL Important Safety Information
More informationAFE8B BATTERY POWERED CRIMP TOOL
Description The AFE8B Battery Powered Crimp Tool is a hand held, self contained crimp tool intended to crimp machined contacts onto copper and aluminum cable. KEEP THIS MANUAL Important Safety Information
More informationWIND STOPPING 14 (WMI) AND WIND STOPPING 16 (WMH) INDUSTRIAL SERIES
Document No: W-IOM Date: 01/13/16 WIND STOPPING 14 (WMI) AND WIND STOPPING 16 (WMH) INDUSTRIAL SERIES Installation, Operation and Maintenance Manual Please read and save these instructions. Read carefully
More informationMMA 160S ARC/MMA WELDER OPERATION INSTRUCTIONS
www.r-techwelding.co.uk MMA 160S ARC/MMA WELDER OPERATION INSTRUCTIONS 2 Thank you for selecting the R-Tech MMA160S Inverter Arc Welder. The MMA160S has many benefits over traditional Arc welders, including
More informationi3000s/i2000 Flex AC Current Probe
i3000s/ AC Current Probe Instruction Sheet Introduction The i3000s 24 Flex, i3000s 36 Flex, and AC Current Probes (the Probe) are used with oscilloscopes, digital multimeters, recorders or data loggers.
More information60V RECHARGEABLE LITHIUM-ION BATTERY
60V RECHARGEABLE LITHIUM-ION BATTERY LB60A00/LB60A03/LB60A01/LB60A02 Owner s Manual TOLL-FREE HELPLINE: 1-855-345-3934 www.greenworkstools.com Read all safety rules and instructions carefully before operating
More informationSpecification of Soneil Battery Charger
SONEIL INTERNATIONAL LIMITED 6033 Shawson Dr., Unit 29, Mississauga, Ontario, Canada L5T 1H8 Ph.: (905) 565-0360 Fax: (905) 565-0352 http://www.soneil.com Revision No.: R01 06/13/2008 Specification of
More informationAC-DC Converter Application Guidelines
AC-DC Converter Application Guidelines 1. Foreword The following guidelines should be carefully read prior to converter use. Improper use may result in the risk of electric shock, damaging the converter,
More informationMOTORTRONICS Solid State AC Motor Control
Solid State AC Motor Control MWH Series Solid State Motor Winding Heater 10 to 80 Amps INSTALLATION & START-UP MANUAL REV 4 6091101MN Table of Contents Chapter 1: General Information... 1 1.1 Introduction
More informationUser s Manual Power Supply. IM E 3rd Edition. Yokogawa Electric Corporation
User s Manual 700938 Power Supply Yokogawa Electric Corporation 3rd Edition Introduction Revisions Thank you for purchasing the 700938 Power Supply. This Instruction Manual contains useful information
More informationQSSE, QSSEX INDUSTRIAL Battery Chargers
C O R P O R A T IO N O P E R A T I N G I N S T R U C T I O N S QSSE, QSSEX INDUSTRIAL Battery Chargers INTRODUCTION The QSE line are electronically controlled float chargers. The batteries are brought
More informationLED Pinspot 2. Snapshot. User Manual
LED Pinspot 2 Snapshot Use on Dimmer Outdoor Use Sound-Activated DMX Master/Slave Auto-ranging Power Supply Replaceable Fuse User-Serviceable User Manual 5200 NW 108th Avenue, Sunrise, FL 33351 U.S.A.
More informationDefender 3000 Series Base Instruction Manual
Defender 3000 Series Base Instruction Manual 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Compliance This product conforms to
More informationModel G14SD Vapor Management System
Instruction Manual Model G14SD Vapor Management System (For Models: DSD and SSD 110/115v) Manufactured in USA for Medivators Reprocessing Systems by: PCI Medical Inc. 12 Bridge Street, PO Box 188 Deep
More informationBMRX Series ROTARY LEVEL CONTROL
BMRX Series ROTARY LEVEL CONTROL OPERATING INSTRUCTIONS PLEASE READ CAREFULLY 925-0292 Rev C TABLE OF CONTENTS GENERAL SPECIFICATIONS... 3 SAFETY SUMMARY... 4 1.0 INTRODUCTION... 5 2.0 INSTALLATION...
More informationLIGHTBOLT MAX EXTENDABLE WORK LIGHT INSTRUCTION MANUAL. Model No. 4063
LIGHTBOLT MAX EXTENDABLE WORK LIGHT Model No. 4063 INSTRUCTION MANUAL MobilePower, LLC. Miami, FL www.mobilepower-us.com Customer Support: (800) 708-8550 customerservice@mobilepower-us.com BEFORE YOU USE
More informationINSTRUCTION MANUAL. 12-Station HD Shop 12V Portable Battery Charger
INSTRUCTION MANUAL 12-Station HD Shop 12V Portable Battery Charger IMPORTANT SAFETY INSTRUCTIONS 1. SAVE THESE INSTRUCTIONS This manual contains important safety and operating instructions for your HD
More informationInstruction Manual. Vortex Mixers
Instruction Manual Vortex Mixers TABLE OF CONTENTS Package Contents............... 1 Warranty............... 1 Installation............... 2 Maintenance & Servicing............... 2 Environmental Conditions...............
More informationPOWERWARE User s Guide VA.
POWERWARE 3110 300 700 VA User s Guide www.powerware.com FCC Part 15 Class B EMC Statements NOTE This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant
More informationGo Power! Manual. GP-1750HD Inverter GP-2500 Inverter
Go Power! Manual GP-1750HD Inverter GP-2500 Inverter Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4 Tel: 866-247-6527 Fax: 866-607-6527 Email: info@gpelectric.com Table of Contents 1. INTRODUCTION...
More information