N2XY IEC XLPE PVC 0.6/1kV Cable

Size: px
Start display at page:

Download "N2XY IEC XLPE PVC 0.6/1kV Cable"

Transcription

1 N2XY IEC XLPE PVC 0.6/1kV Cable Eland Product Group: A2N APPLICATION These power and control cables are used for electricity supply in low voltage installation systems. They are well adapted to underground use in industrial applications with an additional mechanical protection. These cables can be fixed on cable trays, within conduits or fixed to walls. CONSTRUCTION Conductor RE: Class 1 solid copper conductor according to BS EN RM: Class 2 stranded circular or circular compacted conductor according to BS EN Insulation XLPE (Cross-Linked Polyethylene) Bedding PVC (Polyvinyl Chloride) Sheath PVC (Polyvinyl Chloride) CABLE STANDARDS IEC , BS EN/IEC , VDE 0276 part 603 The electrical and dimensional properties of this product are measured by the Technical and Quality Assurance department at the Eland Cables laboratory. Cable performance in respect of conductor resistance, construction quality (workmanship), dimensional consistency, and other parameters are verified to published standards and approved product drawings. Conformance to RoHS (Restriction of the use of Hazardous Substances) is determined and confirmed. CHARACTERISTICS Voltage Rating (Uo/U) 600/1000V Temperature Rating During installation -5 C to +50ºC Fixed Installation: -20 C to +90 C Permissible operating temperature at conductor +90 C (Short circuit temperature: 250ºC) Minimum Bending Radius 12 x overall diameter Core Identification 1 core: Black 2 core: Blue Brown 3 core: Brown Black Grey 3 core including earth: Brown Blue Green/Yellow 4 cores: Blue Brown Black Grey 4 core including earth: Green/Yellow Blue Brown Black 5 cores: Blue Brown Black Grey Black 5 core including earth: Green/Yellow Blue Brown Black Grey 7 cores and Higher: Black cores and White numbers + Green/Yellow Sheath Colour Black technicalspecification 1 of 6

2 DIMENSIONS ELAND PART NO. NO. OF CORES ² OF INSULATION OF SHEATH NOMINAL OVERALL DIAMETER NOMINAL WEIGHT kg/km N2XY Power Cable - 1 core A2N2XY RM A2N2XY RM A2N2XY RM A2N2XY RM A2N2XY RM A2N2XY RM A2N2XY RM A2N2XY RM A2N2XY RM A2N2XY RM A2N2XY RM A2N2XY RM A2N2XY RM A2N2XY RM N2XY Power Cable - 2 core A2N2XY RE A2N2XY RE A2N2XY RE A2N2XY RE A2N2XY RM A2N2XY RM A2N2XY RM A2N2XY RM A2N2XY RM N2XY Power Cable - 3 Core A2N2XY RE A2N2XY RE A2N2XY RE A2N2XY RE A2N2XY RM A2N2XY RM A2N2XY RM A2N2XY RM A2N2XY SM N2XY Power Cable - 3 core with smaller earth conductor A2N2XY316/ RM/10RM A2N2XY325/ RM/16RM 0.9/ A2N2XY335/ RM/16RM 0.9/ A2N2XY350/ RM/25RM 1/ A2N2XY370/ RM/35RM 1.1/ A2N2XY395/ RM/50RM 1.1/ A2N2XY3120/ RM/70RM 1.2/ A2N2XY3150/ RM/70RM 1.4/ A2N2XY3185/ RM/95RM 1.6/ A2N2XY3240/ RM/120RM 1.7/ A2N2XY3300/ RM/150RM 1.8/ of 6 technicalspecification

3 ELAND PART NO. NO. OF CORES ² OF INSULATION OF SHEATH NOMINAL OVERALL DIAMETER NOMINAL WEIGHT kg/km N2XY Power Cable - 4 core A2N2XY RE A2N2XY RE A2N2XY RE A2N2XY RM A2N2XY RE A2N2XY RM A2N2XY RM A2N2XY RM A2N2XY RM A2N2XY RM A2N2XY RM A2N2XY RM A2N2XY RM A2N2XY RM A2N2XY RM A2N2XY RM A2N2XY RM A2N2XY RM N2XY Power Cable - 5 core A2N2XY RE A2N2XY RE A2N2XY RE A2N2XY RM A2N2XY RE A2N2XY RM A2N2XY RM A2N2XY RM A2N2XY RM A2N2XY RM A2N2XY RM A2N2XY RM A2N2XY RM A2N2XY RM A2N2XY RM A2N2XY RM A2N2XY RM N2XY Power Cable - 7 core A2N2XY RE A2N2XY RE A2N2XY RE A2N2XY RM N2XY Power Cable - 10 core A2N2XY RE A2N2XY RE A2N2XY RE A2N2XY RM technicalspecification 3 of 6

4 ELAND PART NO. NO. OF CORES ² OF INSULATION OF SHEATH NOMINAL OVERALL DIAMETER NOMINAL WEIGHT kg/km N2XY Power Cable - 12 Cores A2N2XY RE A2N2XY RE N2XY Power Cable - 14 Cores A2N2XY RE A2N2XY RE N2XY Power Cable - 16 Cores A2N2XY RM N2XY Power Cable - 19 Cores A2N2XY RE A2N2XY RE N2XY Power Cable - 24 Cores A2N2XY RE A2N2XY RE N2XY Power Cable - 30 Cores A2N2XY RE A2N2XY RM N2XY Power Cable - 40 Cores A2N2XY RE A2N2XY RE CONDUCTORS Class 1 Solid Conductors for Single-Core and Multi-Core Cables 2 MAXIMUM RESISTANCE OF CONDUCTOR AT 20 C Circular, Annealed Copper Conductors Plain ohms/km of 6 technicalspecification

5 Class 2 Stranded Conductors for Single-Core and Multi-Core Cables 2 MINIMUM NO. OF WIRES IN THE CONDUCTOR MAXIMUM RESISTANCE OF CONDUCTOR AT 20 C Circular Circular Compacted Annealed Copper Conductor Cu Cu Plain Wires ohms/km ELECTRICAL CHARACTERISTICS Current Carrying Capacity at 30 C 2 Flat In Ground Trefoil SINGLE CORE Flat In Air Trefoil In Ground 2-40 CORE In Air technicalspecification 5 of 6

6 DE-RATING FACTORS For Ground Temperatures other than 20 C GROUND TEMPERATURE 10ºC 15ºC 20ºC 25ºC 30ºC 35ºC 40ºC 45ºC 50ºC DE-RATING FACTOR For Air Temperatures other than 30 C AIR TEMPERATURE 20ºC 25ºC 30ºC 35ºC 40ºC 45ºC 50ºC 55ºC 60ºC DE-RATING FACTOR The information contained within this datasheet is for guidance only and is subject to change without notice or liability. All the information is provided in good faith and is believed to be correct at the time of publication. When selecting cable accessories, please note that actual cable dimensions may vary due to manufacturing tolerances. 6 of 6 technicalspecification

BS 5467 Copper Conductor Multi Core SWA PVC BASEC 0.6/1kV Cable

BS 5467 Copper Conductor Multi Core SWA PVC BASEC 0.6/1kV Cable BS 5467 Copper Conductor Multi Core SWA PVC BASEC 0.6/1kV Cable Eland Product Group: A9S APPLICATION Multi-core PVC cable with steel wire armour (SWA). Power and auxiliary control cables for use in power

More information

SY PVC / BS EN Control Flexible Cable

SY PVC / BS EN Control Flexible Cable SY PVC / BS EN 50525-2-51 Control Flexible Cable Eland Product Group: A5J APPLICATION Used as interconnecting cable for measuring, controlling or regulation in control equipment for assembly and production

More information

Firetec BS 7846 LPCB BASEC Approved Power Cable

Firetec BS 7846 LPCB BASEC Approved Power Cable Firetec BS 7846 LPCB BASEC Approved Power Cable Eland Product Group: A6F APPLICATION Firetec Power is a fire resistant armoured cable suitable for use in fixed installations for power circuits, fire alarm

More information

BS 6724 Copper Conductor Multi Core SWA LSZH BASEC 0.6/1kV Cable

BS 6724 Copper Conductor Multi Core SWA LSZH BASEC 0.6/1kV Cable ed Cable BS 6724 Copper Conductor Multi Core SWA LSZH BASEC 0.6/1kV Cable BS 6724 Copper Conductor Multi Core SWA LSZH BASEC 0.6/1kV Cable Eland Product Group: A9L APPLICATION Multi-core LSZH cable with

More information

6491B / H07Z-R / BS EN Cable

6491B / H07Z-R / BS EN Cable 6491B / H07Z-R / BS EN 50525-3-41 Cable Eland Product Group: A3Z APPLICATION Suitable for use in conduit and for fixed, protected installation. For installations where fire, smoke emission and toxic fume

More information

RFOU 0.6/1kV Power Cable

RFOU 0.6/1kV Power Cable RFOU 0.6/1kV Power Cable Eland Product Group: ASH APPLICATION A flame retardant halogen free power, control and lighting cable for fixed installation. Suitable for use in all conditions in a marine environment

More information

BFOU 0.6/1kV Power Cable

BFOU 0.6/1kV Power Cable BFOU 0.6/1kV Power Cable Eland Product Group: ASH APPLICATION A flame resistant, fire retardant, halogen free cable for fixed installation in various electromechanical and electric equipment, emergency

More information

RE-T2X(st)H SWAH - BS EN Mica XLPE / LSZH / CAM / SWA / LSZH Cable

RE-T2X(st)H SWAH - BS EN Mica XLPE / LSZH / CAM / SWA / LSZH Cable RE-T2X(st)H SWAH - BS EN 50288-7 Mica XLPE / LSZH / CAM / SWA / LSZH Cable Eland Product Group: I APPLICATION These cables are designed to connect electrical instrument circuits and provide counication

More information

(N)SSHÖU O/J, (N)SSHÖU 3E, (N)SSHÖU 3E + ST 0.6/1kV Cable

(N)SSHÖU O/J, (N)SSHÖU 3E, (N)SSHÖU 3E + ST 0.6/1kV Cable ()SSHÖU O/J, ()SSHÖU 3E, ()SSHÖU 3E + ST 0.6/1kV Cable Eland Product Group: A7JS APPLICATIO Heavy duty tough rubber flexible cable with or without individually earth screened cores for dynamic or static

More information

NYY-J Cable. Dungannon Electrical Wholesale Tel: Page 1 of 10

NYY-J Cable. Dungannon Electrical Wholesale Tel: Page 1 of 10 NYY-J Cable Application: A VDE approved, solid conductor, black PVC jacketed, 600/1kV power and control cable. These power cables are designed for energy supply cable ducts, power station, industry and

More information

o o blue-brown Fire Performance BS EN BS EN

o o blue-brown Fire Performance BS EN BS EN Standard Power Cables Low age (600/1000 V) Afumex 90 Armoured Power Cable Cable Approvals > Cable approved to BS6724 > Plain annealed copper stranded (Class 2) for ease of handling Insulation > 90 C -linked

More information

600/1000V XLPE Insulated PVC Sheathed Power Cables (Multicore)

600/1000V XLPE Insulated PVC Sheathed Power Cables (Multicore) 600/1000V XLPE Insulated PVC Sheathed Power Cables (Multicore) FGD400 1RV-R (CU/XLPE/PVC 600/1000V Class 2) Outdoor Cabling Earth Conductor Earth Conductor APPLICATION The cables are mainly used in power

More information

Power & Control Cable IEC

Power & Control Cable IEC (2-, 3-, and 4-cores) U 0 Application For electricity supply and control in public networks and industrial plants; suitable for use in zone 1 and zone 2 group ΙΙ classified areas (IEC 60079-14). Recoended

More information

Power & Control Cable IEC

Power & Control Cable IEC (2-, 3-, and 4-cores) U 0 PVC-Insulation, Application For electricity supply and control in public networks and industrial plants; suitable for use in zone 1 and zone 2 group ΙΙ classified areas (IEC 60079-14).

More information

Technical Data Sheet Unshielded (YY) PVC Control Cable

Technical Data Sheet Unshielded (YY) PVC Control Cable MachineTuff Cables Applications Designed for applications which are installed in occasional flexing and fixed locations. Cable applications include precision control sensors, multi axis control machines,

More information

Technical Data Sheet Unshielded (YY) PVC Control Cable

Technical Data Sheet Unshielded (YY) PVC Control Cable Technical Data Sheet Unshielded (YY) PVC Control Cable MachFlex 350 YY VDE Registered Flexible PVC Control Cables Applications Designed for applications which are installed in occasional flexing and fixed

More information

SY Type Control Cable 0.5mm 2 to 120mm 2 PVC Sheath

SY Type Control Cable 0.5mm 2 to 120mm 2 PVC Sheath Applications Control cables in tool machinery, plant installation, power stations and data equipment. The braided screen of the galvanized steel wires offers the best possible protection against mechanical

More information

BS 6724 Armoured Power Cables, 600/1000V

BS 6724 Armoured Power Cables, 600/1000V BS 6724 Armoured Power Cables, 600/1000V Application These cables are used for power and control circuits, they can offer excellent protection through the use of a heavy galvanized steel wire armour. The

More information

is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire.

is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire. is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire. We are a major supplier of housewiring, low voltage, power and fire resistant cables for

More information

AAAC - ASTM - B All Aluminium Alloy Conductor

AAAC - ASTM - B All Aluminium Alloy Conductor AAAC - ASTM - B All Aluminium Alloy Conductor Eland Product Group: A4A APPLICATION AAAC is used as a bare overhead conductor for power transmission and distribution lines, on aerial circuits that require

More information

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (2-5 Cores)

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (2-5 Cores) www.caledonian-s.co.uk www.addison-s.com 600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (2-5 Cores) FGD400 1RV-R (CU/XLPE/PVC 600/1000V Class 2) FGD400 1RVMV-R (CU/XLPE/PVC/SWA/PVC 600/1000V

More information

FR-3S Fire Resistant Cables

FR-3S Fire Resistant Cables FR-3S Fire Resistant Cables APPLICATION This cable is suitable use in fire extinguishing systems to operate sprinklers, control panels, exit lights in high-rise buildings, hotels, hospitals, sub-ways and

More information

Insulation Colours: Orange (Standard) Natural Natural. Sheath Colours: Orange (Standard) Orange (Standard) Bedding: Black

Insulation Colours: Orange (Standard) Natural Natural. Sheath Colours: Orange (Standard) Orange (Standard) Bedding: Black -I Insulated, non-sheathed Insulated and sheathed Insulated, ed and sheathed 1. : Plain stranded annealed Class 2 Copper. 1.5mm 2 up to 630mm 2 Plain stranded annealed Class 2 Copper. Plain stranded annealed

More information

Technical Data Sheet Shielded (CY) PVC Control Cable

Technical Data Sheet Shielded (CY) PVC Control Cable Technical Data Sheet Shielded (CY) PVC Control Cable MachFlex 375 CY Tinned Copper Braid Shield (TCB) Excellent Noise Immunity Applications Designed for applications which are installed in occasional flexing

More information

BS6724 SWA/LSZH Cable IEC /1000V

BS6724 SWA/LSZH Cable IEC /1000V BS6724 SWA/LSZH Cable IEC 60502 600/1000V Applications: Power cable suitable for power networks, where fire emission of smoke and toxic fumes creates a serious potential threat. Suitable for direct burial.

More information

PVC SHEATH FLAME RETARDANT CABLE TO IEC60332

PVC SHEATH FLAME RETARDANT CABLE TO IEC60332 600/1000V XLPE Insulated PVC Sheathed Armoured Power Cables -5 Cores CU/XLPE/PVC 600/1000V Class CU/XLPE/PVC/SWA/PVC 600/1000V Class Application: The cables are mainly used in power stations, mass transit

More information

Power & Control Cable IEC

Power & Control Cable IEC (2-, 3-, 4,- and 5-cores) U 0 Application For electricity supply and control in public networks and industrial plants; suitable for use in zone 1 and zone 2 group ΙΙ classified areas (IEC 60079-14). Recoended

More information

Power & Control Cables. U o. /U 0.6/1 kv - IEC

Power & Control Cables. U o. /U 0.6/1 kv - IEC Power & Control Cables U o /U 0.6/1 kv - IEC 60502-1 2 KERPEN GmbH & Co. KG 07.2005 Printing errors excepted. Subject to alteration List of Contents Introduction Page B1 Construction Page B3 Use Page B4

More information

SPECIFICATION S VR 1(4) HALOGEN FREE POWER AND CONTROL CABLE FOR MARINE APPLICATIONS LM-HF 0,6/1 kv and TEMAR PHFX-U 0,6/1 kv APPLICATI

SPECIFICATION S VR 1(4) HALOGEN FREE POWER AND CONTROL CABLE FOR MARINE APPLICATIONS LM-HF 0,6/1 kv and TEMAR PHFX-U 0,6/1 kv APPLICATI 1(4) HALOGEN FREE POWER AND CONTROL CABLE FOR MARINE APPLICATIONS LM-HF 0,6/1 kv and TEMAR PHFX-U 0,6/1 kv APPLICATION Power and control cable for fixed installations. Designed to fulfill requirements

More information

The cables you need when you need them

The cables you need when you need them The cables you need when you need them Whether you need standard or specialist cables you re looking in the right place. With a massive range available on short lead-times we can deliver the product you

More information

600/1000V XLPE Insulated, LSZH Sheathed, Armoured Power Cables (2-5 Cores)

600/1000V XLPE Insulated, LSZH Sheathed, Armoured Power Cables (2-5 Cores) www.caledonian-s.co.uk www.addison-s.com 600/1000V XLPE Insulated, LSZH Sheathed, Armoured Power Cables (2-5 Cores) FTX400 1RZ1-R (CU/XLPE/LSZH 600/1000V Class 2) FTX400 1RZ1MZ1-R (CU/XLPE/LSZH/SWA/LSZH

More information

INTRODUCTION NUHAS OMAN QUALITY & RELIABILITY.

INTRODUCTION NUHAS OMAN QUALITY & RELIABILITY. INTRODUCTION Nuhas Oman LLC, an integral part of The Al Bahja Group of Companies, is a Quality producer of: HV, MV and LV Cables Enamelled Copper Wires Oxygen Free Continuous Cast Copper Wire Rods Drawn

More information

BS5467. Standard Power Cables. Low Voltage (600/1000 V) Cable Approvals. Conductor. Insulation. Core Identification. Bedding. Outer Sheath.

BS5467. Standard Power Cables. Low Voltage (600/1000 V) Cable Approvals. Conductor. Insulation. Core Identification. Bedding. Outer Sheath. Standard Power Cables Low age (600/1000 V) BS5467 Cable Approvals > Cable approved to BS5467 > Pla annealed copper stranded (Class 2) for ease of handlg Insulation > 90 C -lked XLPE sulation complyg with

More information

LSZH Fire Resistant Cables

LSZH Fire Resistant Cables 300/500V Single-Core ~ 4-Core Mica Tape Fire Barrier, XLPE Insulated, LSZH Sheathed, Fire Resistant Cable CU/MICA/XLPE/LSZH of the electrical circuit is critical in maintaining power supply. Applications

More information

RG7H1R-1,8/3 26/45 kv RG7H1OR-1,8/3 18/30 kv

RG7H1R-1,8/3 26/45 kv RG7H1OR-1,8/3 18/30 kv Medium voltage - Energy RG7H1R-1,8/3 26/45 kv RG7H1OR-1,8/3 18/30 kv Structure and electrical, physical, mechanical requirements: CEI 20-13 IEC 60502 Flame propagation: EN 60332-1-2 Measurement of partial

More information

N2XSEFGbY 3 x (25-300) mm² 3.6/6 kv

N2XSEFGbY 3 x (25-300) mm² 3.6/6 kv N2XSEFGbY 3 x (25-300) mm² 3.6/6 kv N2XSEFGbY 3 x (25-300) mm² 3.6/6 kv (Copper, XLPE Insulated, Copper Tape,, PVC Sheathed) 25 38.5 2,603 35 41.5 3,074 50 44.5 3,641 70 48.5 4,536 95 52.0 5,542 120 56.0

More information

SY Cable. Dungannon Electrical Wholesale Tel: Page 1 of 8

SY Cable. Dungannon Electrical Wholesale Tel: Page 1 of 8 SY Cable Application: Measuring and control cable to connect equipment in production lines / assembly lines and conveyor systems. Can be used both fixed and flexible installations. Techincal Data: 1 Plain

More information

Technical Data Sheet Shielded (CY) PVC Control Cable

Technical Data Sheet Shielded (CY) PVC Control Cable MachineTuff Cables Tinned Copper Braid Shield (TCB) Excellent Noise Immunity Applications Designed for applications which are installed in occasional flexing and fixed locations. Cable applications include

More information

Power & Control Cables

Power & Control Cables The Quality Connection Power & Control Cables U o /U 0.6/1 kv - IEC 60502-1 2 The Quality Connection www.leoni-industrial-projects.com The LEONI Group Cable expertise for the most various industrial markets.

More information

Complete range of transformers for any applications or size

Complete range of transformers for any applications or size Complete range of transformers for any applications or size SURGE PROTECTOR KAB-15A(15A/110V) KAB-10A(10A/V) 3min delay Specifications: Input voltage: 160V to 40V Output voltage: 110/V +/- 3% Frequency:

More information

600/1000V, PVC Insulated Cables according to IEC

600/1000V, PVC Insulated Cables according to IEC 8 Any inquiries, please feel free to contact 600/1000V, PVC Insulated s according to IEC 60502-1 Single core(unarmoured) Two core(unarmoured) Three core(unarmoured) Three core +1(unarmoured) Four core(unarmoured)

More information

1 Conductor Class 5 flexible annealed plain copper conductor

1 Conductor Class 5 flexible annealed plain copper conductor YY Control Cable Application: YY Control is a flexible mulit-core cable with class 5 flexible annealed plain copper conductors, PVC insulation, and a grey PVC sheath. YY Cable is used in fixed installations

More information

Your Partner in Safe Power Solutions. About RESCAB

Your Partner in Safe Power Solutions. About RESCAB Your Partner in Safe Power Solutions About RESCAB Red Sea Cables Company (RESCAB) was established as a closed joint stock company in 2008 in the Kingdom of Saudi Arabia with a capital of 370 million SAR.

More information

Technical Data Sheet Shielded (CY) PVC Control Cable

Technical Data Sheet Shielded (CY) PVC Control Cable Technical Data Sheet Shielded (CY) PVC Control Cable MachFlex 350 CY VDE Registered Tinned Copper Braid Shield (TCB) Excellent Noise Immunity Applications Designed for applications which are installed

More information

N2XSEBY 3 x (25-300) mm² 3.6/6 kv

N2XSEBY 3 x (25-300) mm² 3.6/6 kv N2XSEBY 3 x (25-300) mm² 3.6/6 kv N2XSEBY 3 x (25-300) mm² 3.6/6 kv (Copper, XLPE Insulated, Copper Tape,, PVC Sheathed) 25 38.5 2,417 35 41.0 2,865 50 44.0 3,391 70 48.0 4,272 95 51.5 5,266 120 55.5 6,232

More information

Materials Evolved* BS EN BS EN IEC IEC (Upon customer request) (Red, Black) or (Brown, Blue)

Materials Evolved* BS EN BS EN IEC IEC (Upon customer request) (Red, Black) or (Brown, Blue) XLPE INSULATED AND PVC OR LOW SMOKE HALOGEN FREE (LSHF) SHEATHED CABLES Voltage Rating (Uo/U) : 00/00V, 1/0V or 00/3V Standards Complied Main Specification Materials Test Methods Flame Retardant Test Test

More information

FR-N1X1G1. Low voltage - Energy, cabling, signalling and control

FR-N1X1G1. Low voltage - Energy, cabling, signalling and control Low voltage - Energy, cabling, signalling and control FR-N1X1G1 Construction: NF C 32-323 NF C 32-323/1 Fire propagation: NF EN 60332-3-24 NF C 32-070 C1 IEC 60332-3-24 C Flame propagation: NF EN 60332-1-2

More information

NA2XSEKRY 3 x (25-300) mm² 3.6/6 kv

NA2XSEKRY 3 x (25-300) mm² 3.6/6 kv NA2XSEKRY 3 x (25-300) mm² 3.6/6 kv NA2XSEKRY 3 x (25-300) mm² 3.6/6 kv (Aluminium, XLPE Insulated, Copper Tape, Lead Sheathed,, PVC Sheathed) 25 47.5 5,292 35 50.5 5,960 50 53.5 6,694 70 58.5 7,816 95

More information

N2XSERY 3 x (25-300) mm² 3.6/6 kv

N2XSERY 3 x (25-300) mm² 3.6/6 kv N2XSERY 3 x (25-300) mm² 3.6/6 kv N2XSERY 3 x (25-300) mm² 3.6/6 kv (Copper, XLPE Insulated, Copper Tape,, PVC Sheathed) 25 41.0 3,102 35 43.5 3,587 50 48.0 4,576 70 52.0 5,579 95 55.5 6,642 120 59.5 7,711

More information

NA2XKR(AL)Y 1 x (16-800) mm² 0.6/1

NA2XKR(AL)Y 1 x (16-800) mm² 0.6/1 NA2XKR(AL)Y 1 x (16-800) mm² 0.6/1 NA2XKR(AL)Y 1 x (16-800) mm² 0.6/1 kv Al / XLPE / LS / PVC / AWA / PVC (, XLPE Insuled, ed, Aluminium Wire Armor, ed) Construction Da 16 23.0 1,102 25 23.0 1,104 35 23.0

More information

NA2XSEKY 3 x (25-300) mm² 3.6/6 kv

NA2XSEKY 3 x (25-300) mm² 3.6/6 kv NA2XSEKY 3 x (25-300) mm² 3.6/6 kv NA2XSEKY 3 x (25-300) mm² 3.6/6 kv (Aluminium, XLPE Insulated, Copper Tape, Lead Sheathed, PVC Sheathed) 25 39.5 3,292 35 43.0 3,824 50 46.0 4,419 70 50.5 5,264 95 54.5

More information

H07RN-F TITANEX (industrial flexible)

H07RN-F TITANEX (industrial flexible) Description Application TITANEX flexible cable is intended for installations with moving equipment, electric appliances and for building sites. The cable may be rated 0,6/1 kv where the installation has

More information

600/1000 V. 5. Flame Retardancy VDE , DIN EN , IEC

600/1000 V. 5. Flame Retardancy VDE , DIN EN , IEC MachineTuff Cables Low Voltage Control & Power Cable Galvanized Steel Wire Braid Armored (GSWB) > Excellent Mechanical Protection Applications Designed for applications which are installed in occasional

More information

600/1000V, XLPE Insulated Cables according to IEC

600/1000V, XLPE Insulated Cables according to IEC 600/1000V, XLPE Insulated Cables according to IEC 60502-1 Single core(unarmoured) Two core(unarmoured) Three core(unarmoured) Three core +1(unarmoured) Four core(unarmoured) Multi- core(unarmoured) Single

More information

Data sheet chainflex CFSOFT1

Data sheet chainflex CFSOFT1 to 5 x d Highly flexible, soft design PVC outer jacket Oil-resistant Flame retardant 1. Outer jacket: Pressure extruded, oil-resistant PVC mixture 2. Core insulation: Mechanically high-quality TPE mixture

More information

Chemical resistance Accidental

Chemical resistance Accidental Industrial flexible cable, insulation and outer sheath in elastomer. Oil resistant, flame retardant according to IEC/EN 60332-1-2 standard. Description Application flexible cable is intended for installations

More information

PROTEC. Screened Wiring Cable. Updated to meet new requirements of BS 8436:2011 BASEC approved.

PROTEC. Screened Wiring Cable. Updated to meet new requirements of BS 8436:2011 BASEC approved. PROTEC Screened Wiring Cable Updated to meet new requirements of BS 8436:2011 BASEC approved www.aeicables.co.uk PROTEC CABLES Manufactured and designed to BS 8436 and IS 273 Protec Low Smoke Zero Halogen

More information

Unarmoured Single-Core Cables to BS6883

Unarmoured Single-Core Cables to BS6883 Unarmoured Single-Core Cables to BS TAC. EPR. SW 00/00 V 1 Application Unarmoured cable for use where mechanical protection is not required for fixed wiring in ships and in mobile and fixed offshore units

More information

Building & Infrastructure Cables DELIVERING ENERGY

Building & Infrastructure Cables DELIVERING ENERGY Building & Infrastructure Cables DELIVERING ENERGY Keystone Cable is a Leading Singaporebased Cable Manufacturer and Supplier. Keystone Cable Market Reach Established since 1990, Keystone Cable has an

More information

N2XR(AL)Y 1 x (25-800) mm² 0.6/1 kv

N2XR(AL)Y 1 x (25-800) mm² 0.6/1 kv N2XR(AL)Y 1 x (25-800) mm² 0.6/1 kv N2XR(AL)Y 1 x (25-800) mm² 0.6/1 kv Cu / XLPE / AWA / PVC (, XLPE Insuled, Aluminium Wire Armor, ed) 25 16.6 503 35 17.7 612 50 19.5 783 70 21.5 1,014 95 23.5 1,280

More information

Flame Retardant Individual and Overall Screened, Armoured Instrumentation Cables (Multipair)

Flame Retardant Individual and Overall Screened, Armoured Instrumentation Cables (Multipair) Caledonian Flame Retardant Instrumentation Cables www.caledonian-cables.co.uk www.addison-cables.com Flame Retardant Individual and Overall Screened, Armoured Instrumentation Cables (Multipair) RE-2X(st)YSWAY

More information

NA2XSEY 3 x (25-300) mm 2 3.6/6 kv

NA2XSEY 3 x (25-300) mm 2 3.6/6 kv NA2XSEY 3 x (25-300) mm 2 3.6/6 kv NA2XSEY 3 x (25-300) mm 2 3.6/6 kv (Aluminium, XLPE Insulated, Copper Tape, PVC Sheathed) 25 36.5 1,380 35 39.5 1,620 50 42.0 1,908 70 46.5 2,322 95 50.0 2,781 120 54.0

More information

BS EN Natural. (Orange for Non-sheathed) (Red & Black) or (Brown & Blue) (Red, Yellow, Blue) or (Brown, Black, Grey)

BS EN Natural. (Orange for Non-sheathed) (Red & Black) or (Brown & Blue) (Red, Yellow, Blue) or (Brown, Black, Grey) LOW SMOKE HALOGEN FREE (LSHF) FIRE RESISTANT CABLES Voltage Rating (Uo/U) : /0V, /7V or 00/00V Standards Complied Main Specification Fire Tests Flame Retardant Test Test on Acid Gas Evolved Smoke Density

More information

Data sheet chainflex CF8821

Data sheet chainflex CF8821 1. Outer jacket: Pressure extruded, oil-resistant PVC mixture 2. Overall shield: Braiding made of tinned copper wires 3. Overall banding: Plastic foil 4. Core insulation: Mechanically high-quality TPE

More information

ACSR - ASTM - B Aluminium Conductor Steel Reinforced

ACSR - ASTM - B Aluminium Conductor Steel Reinforced SR - ASTM - B Aluminium Conductor Reinforced Eland Product Group: A4A APPLICATION SR conductor consists of a solid or stranded steel core surrounded by strands of aluminium. SR conductor is available in

More information

Caledonian. BS 6346 PVC Insulated, Armored Power and Control Cables. Addison.

Caledonian. BS 6346 PVC Insulated, Armored Power and Control Cables. Addison. Caledonian BS 6346 PVC Insulated, Armored Power and Control Cables www.caledonian-s.co.uk www.caledonian-s.com Addison Company Profile Caledonian. established in 1978.offers one of the most complete lines

More information

CONTROL CABLES CABLES FZE.

CONTROL CABLES CABLES FZE. CONTROL CABLES CABLES FZE www.markcables.com Index Introduction 03 Particulars & Guarantees 05 Copper Conductor, PVC Insulated, PVC Sheathed Cables 08 Copper Conductor, XLPE Insulated, PVC Sheathed Cables

More information

flame Retardant overall screened Instrumentation cables (Multicore)

flame Retardant overall screened Instrumentation cables (Multicore) Caledonian flame Retardant Instrumentation cables www.caledonian-cables.co.uk www.addison-cables.com flame Retardant overall screened Instrumentation cables (Multicore) Re-2X(st)y Re-2X(st)ysWay PVC Outer

More information

Any inquiries, please feel free to contact or Caledonian

Any inquiries, please feel free to contact or Caledonian Caledonian Low Voltage cables to IEC 60502 Standard www.caledonian-cables.co.uk www.caledonian-cables.net 1 Addison Company Profile Caledonian. established in 1978.offers one of the most complete lines

More information

Technical attributes

Technical attributes Technical attributes Standards adapted to DIN VDE 0281 Conductor material Cu, bare Conductor type flexible Conductor standard IEC 60228 Conductor category 5 Core insulation Core s black, number-coded,

More information

sa B-CABLES nv PROTOLON(ST) NTSCGEWOEU Medium Voltage Flexible Cables for Use In Water sa B-CABLES nv ENERGY

sa B-CABLES nv PROTOLON(ST) NTSCGEWOEU Medium Voltage Flexible Cables for Use In Water sa B-CABLES nv ENERGY PROTOLON(ST) NTSCGEWOEU Medium Voltage Flexible Cables for Use In Water ENERGY Technical Data Electrical Thermal Type Type designation PROTOLON(ST) NTSCGEWÖU Approvals/ standards DIN VDE 0250 part 813

More information

Caledonian Medium Voltage Cables

Caledonian Medium Voltage Cables Three Core Cables to VDE 0276 APPLICATIONS: The three core cables are designed for distribution of electrical power with nominal voltage Uo/U ranging from 3.6/6.6KV to 19/33KV and frequency 50Hz. They

More information

H05 V-K PVC-Single Cores, fine wire stranded

H05 V-K PVC-Single Cores, fine wire stranded H05 VK PVCSingle Cores, fine wire stranded Technical data PVC single cores to DINVDE0283 H05 VK/H05 VU to DINVDE028 part3, HD2.3S3 and IEC02273 Temperature range flexing 5 C to +70 C fixed installation

More information

0.6/1kV Al-Cu PVC Insulated PVC Sheathed Power Cable

0.6/1kV Al-Cu PVC Insulated PVC Sheathed Power Cable 0.6/1kV - PVC Insulated PVC ed Power Cable SPECIFICATIONS AND STANDARDS: 1.IEC60502-1;VDE 0276-603 ;ICEA S-95-658 ;AS/NZS 5000.1; BS; JIS. 2.Rated Voltage: 0.6/1kV 3. Number cores : One core, two cores,

More information

LOW VOLTAGE c a b l e s

LOW VOLTAGE c a b l e s LOW VOLTAGE c a b l e s MYSORE PLANT SILVASSA PLANT MANUFACTURES A RANGE OF LOW VOLTAGE CABLES AT ITS FACILITIES AT SILVASSA AND MYSORE The Silvassa unit manufactures LV Cables since the year 2000. XLPE/

More information

PRODUCT INFORMATION H07V-K

PRODUCT INFORMATION H07V-K GmbH PRODUCT INFORMATION European cable type certification Cables' marking also stands for the international endorsement of national certification institutes' testing marks and certificates,

More information

sa B-CABLES nv PROTOLON(ST) NTSCGEWOEU.../3E Medium Voltage Flexible Cables for Use in Water with Copper Core Shield sa B-CABLES nv ENERGY

sa B-CABLES nv PROTOLON(ST) NTSCGEWOEU.../3E Medium Voltage Flexible Cables for Use in Water with Copper Core Shield sa B-CABLES nv ENERGY PROTOLON(ST) NTSCGEWOEU.../3E Medium Voltage Flexible Cables for Use in Water with Copper Core Shield ENERGY Technical Data Electrical Thermal Type Type designation PROTOLON (ST) NTSCGECEWÖU.../3E Approvals/

More information

VDE-registered oil-resistant PVC control cable with black outer sheath for a wide range of applications

VDE-registered oil-resistant PVC control cable with black outer sheath for a wide range of applications VDE-registered oil-resistant PVC control cable with black outer sheath for a wide range of applications - PVC control cable, VDE registered, oil resistant, flexible and UV-resistant for various applications,

More information

PRODUCT INFORMATION. ÖLFLEX HEAT 180 SiF

PRODUCT INFORMATION. ÖLFLEX HEAT 180 SiF GmbH PRODUCT INFORMATION Versatile stranded conductors with extended temperature range Halogen-free Temperature-resistant Info Flexible fine-wire copper conductor Application range Areas with high ambient

More information

Company Profile. Caledonian Medium Voltage Cables

Company Profile. Caledonian Medium Voltage Cables Caledonian Medium Voltage Cables Company Profile Caledonian develops, manufactures and markets a totally integrated product line of Medium Voltage Cables for a diverse variety of technological applications.

More information

HYDROFIRM(T) S1BB-F and S1BBH2-F 0,6/1 kv. Round and Flat Cables for Drinking Water Application KTW/DVGW W270/ACS/WRAS ENERGY

HYDROFIRM(T) S1BB-F and S1BBH2-F 0,6/1 kv. Round and Flat Cables for Drinking Water Application KTW/DVGW W270/ACS/WRAS ENERGY HYDROFIRM(T) S1BB-F and S1BBH2-F 0,6/1 kv Round and Flat Cables for Drinking Water Application KTW/DVGW W270/ACS/WRAS ENERGY Technical Data Electrical Thermal Trademark Type designation Specification Application

More information

PRODUCT INFORMATION. UNITRONIC LiYCY. Benefits Overall shield minimises electrical interference Versatile application possibilities

PRODUCT INFORMATION. UNITRONIC LiYCY. Benefits Overall shield minimises electrical interference Versatile application possibilities Shielded data cable with colour code according to DIN 47100 - shielded PVC data cable with colour code DIN 47100 for use in machinery and apparatus construction and in measurement, control and regulation

More information

3. Fire Resistant Cables

3. Fire Resistant Cables Fire Resistant Cables The -to-fire is the term used to describe how long a cable continues to operate in a fire. This may be of primary concern, for instance, in life safety of fire fighting installations.

More information

Corflex. Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables. Introduction Applications... 3

Corflex. Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables. Introduction Applications... 3 Corflex Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables Introduction................................. 2 Applications................................. 3 Corflex PL 300V Instrumentation

More information

CORDAFLEX(SMK) (N)SHTÖU Tough Rubber-Sheathed Reeling Cables

CORDAFLEX(SMK) (N)SHTÖU Tough Rubber-Sheathed Reeling Cables CORDAFLEX(SMK) (N)SHTÖU Tough Rubber-Sheathed Reeling Cables 3 SK1_1-001.tif 4 SK1_1-003.tif SK1_1-00.tif Selection and dimensioning criteria Refer to Section 4 for further details Ü Type CORDAFLEX(SMK)

More information

www. h itech controls.com (800) I (303) Click or Call for a Quotel Photo: HELUKABEL Robotic Cables C HELUKABEL

www. h itech controls.com (800) I (303) Click or Call for a Quotel Photo: HELUKABEL Robotic Cables C HELUKABEL Photo: HELUKABEL Robotic Cables Robotic Cables With over 30 years of experience with cables and lines, we also have the right solutions for the demands placed on the components to be installed by the applications

More information

Data sheet chainflex CF130.UL

Data sheet chainflex CF130.UL 1. Outer jacket: Pressure extruded, gusset-filling PVC mixture 2. CFRIP: Tear strip for faster cable stripping 3. Core insulation: Mechanically high-quality TPE mixture 4. Conductor: Fine-wire strand consisting

More information

burning o Red o Black o Blue o Yellow o Brown o Grey Fire Performance BS EN

burning o Red o Black o Blue o Yellow o Brown o Grey Fire Performance BS EN LSOH Wiring Cables Low Voltage (/7 V) LSOH Conduit Wire (HO7ZR) 91B Cable Approvals Cable approved to BS711 Key Applications > Installation in surface mounted or embedded conduits, or similar closed systems

More information

ÖLFLEX CLASSIC 110 CY

ÖLFLEX CLASSIC 110 CY Screened PVC control cable with transparent outer sheath - PVC control cable, VDE registered, screened, flexible and numbered for various applications, U 0 /U: 300/500V Info CPR: choice under www.lappkabel.com/cpr

More information

Caledonian Medium Voltage Cables Three Core Cables to VDE 0276-

Caledonian Medium Voltage Cables Three Core Cables to VDE 0276- Three Core Cables to VDE 0276 APPLICATIONS The three core cables are designed for distribution of electrical power with nominal voltage Uo/U ranging from 3.6/6.6KV to 19/33KV and frequency 50Hz. They are

More information

ENERGY. TECWATER EMV-FC S1BC4N8-F 0,6/1 kv. Screened Cable for Water Application

ENERGY. TECWATER EMV-FC S1BC4N8-F 0,6/1 kv. Screened Cable for Water Application ENERGY TECWATER EMV-FC S1BC4N8-F 0,6/1 kv Screened Cable for Water Application Technical Data Trademark Type designation Specification Application TECWATER EMV-FC S1BC4N8-F Design and tests according to

More information

S.No. Tender Queries BRPL Reply 1 For 11KV(E) 3Cx300sqmm A2XWY High Ampacity cable conductor details specification not

S.No. Tender Queries BRPL Reply 1 For 11KV(E) 3Cx300sqmm A2XWY High Ampacity cable conductor details specification not S.No. Tender Queries BRPL Reply 1 For 11KV(E) 3Cx300sqmm A2XWY High Ampacity cable conductor details specification not clear.please provide Specification for High ampacity HT Cable with Trapezoidal wire

More information

PRODUCT INFORMATION. UNITRONIC LiYCY. Benefits Overall braid minimises electrical interference Multifunctional application possibilities

PRODUCT INFORMATION. UNITRONIC LiYCY. Benefits Overall braid minimises electrical interference Multifunctional application possibilities Screened data transmission cable with colour code acc. to DIN 47100 : Low-frequency PVC data cable DIN 47100 coded Flexible (0.34mm² multi-wire Maxi TERMI-POINT ) Flame retardant Screened, Instrumentation

More information

ENERGY. HYDROFIRM(T) EMV-FC S1BC4B-F 0,6/1 kv. Screened Cable for Drinking Water Application KTW/ACS

ENERGY. HYDROFIRM(T) EMV-FC S1BC4B-F 0,6/1 kv. Screened Cable for Drinking Water Application KTW/ACS ENERGY HYDROFIRM(T) EMV-FC S1BC4B-F 0,6/1 kv Screened Cable for Drinking Water Application KTW/ACS Technical Data Trademark Type designation Specification Application HYDROFIRM(T) EMV-FC S1BC4B-F Design

More information

Data sheet chainflex CF5

Data sheet chainflex CF5 1. Outer jacket: Pressure extruded, gusset-filling, oilresistant PVC mixture 2. Core insulation: Mechanically high-quality TPE or PVC mixture 3. CFRIP: Tear strip for faster cable stripping 4. Conductor:

More information

Introduction. Nexans wire and cable. Contact us for all your wire and cable needs

Introduction. Nexans wire and cable. Contact us for all your wire and cable needs Introduction Nexans is one of the largest wire and cable manufacturers in the world, and in North America. In North America we manufacture in locations across the United States and Canada. We design and

More information

Cables for Railway Technology

Cables for Railway Technology Cables for Railway Technology www.sab-worldwide.com Content q In case that you don t find a suitable cable for your special application, we are always prepared to design a cable according to your individual

More information

Global data. Electrical parameters

Global data. Electrical parameters ()TSCGEWOEU TEAX TTS 3,6/6 kv: Application Flexible medium voltage reeling cable for application under high mechanical stresses, e.g. high travel speeds, dynamic loads, multiple changes of direction into

More information

Data sheet chainflex CF240

Data sheet chainflex CF240 1. Outer jacket: Pressure extruded, oil-resistant PVC mixture 2. Overall shield: Aluminum/Polyester tape and extremely bending-resistant braiding made of tinned copper wires. 3. Banding: Plastic foil 4.

More information

PRODUCT INFORMATION MULTI-STANDARD SC 2.1. U.I. Lapp GmbH

PRODUCT INFORMATION MULTI-STANDARD SC 2.1. U.I. Lapp GmbH GmbH PRODUCT INFORMATION USA: UL-listed (MTW), Canada: CSA (TEW), Europe: H07V-K (depending on cross s.), tin-coated strands For use in the most important global markets Reduction in technical documentation

More information