Complete range of transformers for any applications or size

Size: px
Start display at page:

Download "Complete range of transformers for any applications or size"

Transcription

1 Complete range of transformers for any applications or size

2 SURGE PROTECTOR KAB-15A(15A/110V) KAB-10A(10A/V) 3min delay Specifications: Input voltage: 160V to 40V Output voltage: 110/V +/- 3% Frequency: 50/60Hz Temperature rise (input voltage 0V, output voltage V and at rated load):less than 75 resistance: more than 3Mohm at DC 500V AUTO TRANSFORMERS 75watts 000watts can be done to any specification

3 Electrical Cable Product Group PVC Flexible 491X Flexible Cable to BS6004 H05V-K H07V-K Designed for use in the switch control, relay and instrumentation panels of power switchgear and for purposes such as internal connectors in rectifier equipment, motor starters and controllers. BS6004, CENELEC HD1.3 Class 5 flexible plain copper conductor to BS EN 608:05 (previously BS6360) PVC (Polyvinyl Chloride) Type TI 1 to BS7655 Colour Black, Blue, Green/Yellow, Red, Yellow, White, Violet, Brown, Grey, Orange, Pink H05V-K 300/500V, H07V-K 0/750V 0 C to +70 C Minimum Bending Radius 6 x overall diameter H05V-K H07V-K ² Nominal Overall Diameter A5VKBK A5VKBK ² Nominal Overall Diameter A7VKBK A7VKBK A7VKBK A7VKBK A7VKBK A7VKBK A7VKBK A7VKBK A7VKBK A7VKBK A7VKBK s Class 5 flexible Copper s for Single Core and Multi-Core cables Maximum Diameter of Wires in Maximum Resistance of at ºC Plain Wires ohms/km Metal-Coated Wires ohms/km Table in accordance with BS EN 608:05 (previously BS6360) Electrical Characteristics Resistance Values (ohms per kilometre and Mohms per kilometre) H05V-K ² Resistance at C Max. ohms/km Resistance at 70 C Min. Mohms/Km A5VKBK A5VKBK

4 6491X Cable to BS6004 H07V-R/H07V-U AX Fixed Wiring 6491X Cable H07V-R/H07V-U to BS6004 is suitable for power and lighting circuits and building wiring. The cable is intended for use in semi-flush exposed conduits and embedded conduits as well as in closed installation ducts, and is ideal for the internal wiring of appliances and apparatus. BS6004 H07V-R: Class stranded plain copper conductors to BS EN 608:05 (previously BS6360) H07V-U: Class 1 solid plain copper conductor to BS EN 608:05 (previously BS6360) PVC (Polyvinyl Chloride) Type TI1 to BS7655 Colour Red, Black, Blue, Yellow, Brown, White, Green/Yellow, Grey 0/750V 0 C to +70 C Minimum Bending Radius Up to 10²: 3 x overall diameter 10² to 5²: 4 x overall diameter Above 5²: 5 x overall diameter No. of Cores x Nominal Cross Sectional Area # x Nominal Thickness of Maximum Overall Diameter AXBK x AXBK005 1 x AX* x AX* x AX*010 1 x AX*016 1 x AX*05 1 x AX*035 1 x AX*050 1 x AX*070 1 x AX*095 1 x AX*1 1 x AX*150 1 x AX*185 1 x AX*40 1 x AX*300 1 x *s shown above designate the sheath colour (*). For each colour substitute * for a colour code as listed below. e.g. ATRD0040 = 4.0 Red, ATPK0015 = 1.5 Pink Colour Black Blue Grey Green/Yellow Red Yellow Brown White Code BK BL GR GY RD YW BR WH s Class stranded conductors for Single Core and Multi-Core cables Nominal Cross Sectional Area Minimum Number of Wires in the Maximum Resistance of at ºC Circular Circular Compacted Shaped Annealed Copper Cu Al Cu Al Cu Al Plain Wires ohms/km Table in accordance with BS EN 608:05 (previously BS6360) Datasheet Continues»

5 Eland Cables Datasheet Electrical Cable Product Group PVC Flexible Tri-rated Cable Eland Product Group Reference AT High temperature, flame retardant cable designed for use in the switch control, relay and instrumentation panels of power switchgear and for purposes such as internal connectors in rectifier equipment, motor starters and controllers. BS631 Type CK UL Subj.758 CSA c.. No. 17 (only applicable for sizes up to 1 ) Class 5 flexible plain copper conductor to BS EN 608:05 (previously BS6360) PVC (Polyvinyl Chloride) Colour Black, Red, Blue, Light Blue, Dark Blue, Yellow, Green/Yellow, Grey, Brown, Orange, White, Violet, Green, Pink BS631: 600/1000V UL, CSA: 600V BS631: 90 C (105 C for 15,000 hours) UL, CSA: 105 C Minimum Bending Radius 6 x overall diameter Note Cables above 1² in size are referred to as Bi-rated since the CSA standard applies only to sizes up to and including 1² Eland Part Number No of Cores x Nominal Cross Sectional Area # x AWG Nominal Thickness of Nominal Overall Diameter UL Style Number AT* x AT* x AT* x AT* x AT*005 1 x AT* x AT* x AT*010 1 x AT*016 1 x AT*05 1 x AT*035 1 x AT*050 1 x AT*070 1 x / AT*095 1 x / AT*1 1 x / AT*150 1 x MCM AT*185 1 x MCM AT*40 1 x MCM *s shown above designate the sheath colour (*). For each colour substitute * for a colour code as listed below. e.g. ATRD0040 = 4.0 Red, ATPK0015 = 1.5 Pink Colour Black Green Blue Light Blue Dark Blue Grey Green/ Yellow Orange Red Pink Yellow Violet Brown White Code BK GN BL LTBL DKBL GR GY OR RD PK YW VI BR WH s Class 5 flexible Copper s for Single Core and Multi-Core cables 1 3 Maximum Diameter of Wires in Maximum Resistance of at ºC Plain Wires ohms/km Table in accordance with BS EN 608:05 (previously BS6360) Datasheet Continues» Issue_0_0310

6 Electrical Cable Product Group PVC Flexible 18-Y Flexible Cable H03VV-F Light duty cable for use in domestic premises, kitchens and offices. For use with light portable appliances such as radios, table lamps and office machines. BS6500, CENELEC HD1.5, VDE 81 Class 5 flexible plain copper conductors to BS EN 608:05 (previously BS6360) PVC (Polyvinyl Chloride) to BS7655 Sheath PVC (Polyvinyl Chloride) to BS7655 Sheath Colour Black or White Core Identification Cores: Blue, Brown 3 Cores: Green/Yellow, Blue, Brown 300/500V 0 C to +70 C Minimum Bending Radius 6 x overall diameter No x Cores x Nominal Cross Sectional Area # x Nominal Thickness of Nominal Thickness of Sheath Nominal Overall Diameter A3Y0050* x A3Y0075* x A3Y030050* 3 x A3Y030075* 3 x A3Y040050* 4 x *s shown above designate the sheath colour (*). For each colour either substitute * for BK (black) or WH (white) s Class 5 flexible Copper s for Single Core and Multi-core cables 1 3 Maximum Diameter of Wires in Maximum Resistance of at ºC Plain Wires ohms/km Table in accordance with BS EN 608:05 (previously BS6360) Electrical Characteristics Current Carrying Capacity (amperes): and Mass Supportable (kg) Cross Sectional Area ² Single Phase AC Current Carrying Capacity Three Phase AC Maximum Mass Supportable by Twin Flexible Cord (see Regulations 5.7. and ) kg Rating factor for ambient temperature 60ºC thermoplastic or thermosetting insulated cords: Ambient Temperature 35ºC 40ºC ºC 50ºC 55ºC Rating Factor The above table is in accordance with Table 4F3A of the 17th Edition of IEE Wiring Regulations. Voltage Drop (per ampere per metre) Cross Sectional Area ² DC or Single Phase AC mv/a/m Three Phase AC mv/a/m operating temperature: 60ºC The above table is in accordance with Table 4F3B of the 17th Edition of IEE Wiring Regulations.

7 Electrical Cable Product Group Fixed Wiring 64-B LSZH Twin and Earth Domestic wiring cable for the surface wiring of sockets and lighting where fire, smoke emission and toxic fumes create a potential threat to life and equipment. Can be installed in fixed installations in dry or damp premises clipped to surface, on trays or in free air where mechanical damage would not be an issue. Suitable for laying in conduit or trunking where mechanical protection is required. BS711 EN 5068 BS EN EN 5067 EN 5065 IEC 6033 Plain copper conductors to BS EN 608:05 (previously BS6360) Class 1 solid: 1.5² and.5² Class stranded: 4.0², 6.0² and 10.0² Class stranded compacted: 16.0² Circuit Protection (Earth) Class 1 solid plain copper conductor: 1.0², 1.5²,.5², 4² and 6² Class stranded plain copper conductor: 10² and 16² XLPE (Cross-linked Polyethylene) Sheath LSZH (Low Smoke Zero Halogen) Sheath Colour White 300/500V Operating Temperature: -5 C to 90 C Note: Where a conductor operates at a temperature exceeding 70 C it shall be ascertained that the equipment connected to the conductor is suitable for the conductor operating temperature (see regulation 51-0 of BS7671, the 16th Edition of IEE Wiring Regulations) No. of Cores x Nominal Cross Sectional Area # x Nominal Thickness of Nominal Thickness of Sheath Nominal Cable Dimension (Thickness x Width) A9T64B015W x x A9T64B05W x x A9T64B040W x x A9T64B060W x x A9T64B10W x x A9T64B16W x x A9T643B015W 3 x x s Class stranded conductors for Single Core and Multi-Core cables Minimum Number of Wires in the Maximum Resistance of at ºC Circular Circular Compacted Annealed Copper ohms/km Table in accordance with BS EN 608:05 (previously BS6360) Electrical Characteristics Current Carrying Capacity (amperes) and Voltage Drop (per ampere per metre) Nominal Cross Sectional Area Reference Method 100# (Above a plasterboard ceiling covered by thermal insulation not exceeding 100 in thickness) Reference Method 101# (Above a plasterboard ceiling covered by thermal insulation exceeding 100 in thickness) Reference Method 10# (In a stud wall with thermal insulation with cable touching the inner wall surface) Reference Method 103# (In a stud wall with thermal insulation with cable not touching the inner wall surface) Reference Method C* (Clipped Direct) Reference Method A* (Enclosed in conduit in an insulated wall) Voltage Drop mv/a/m Ambient temperature: 30ºC operating temperature: 70ºC Wherever practicable, a cable is to be fixed in a position such that it will not be covered with thermal insulation. Regulation 53.7, BS5803-5: Appendix C: Avoidance of overheating of electric cables, Building Regulations Approved document B and Thermal insulation: avoiding risks, BR 6, BRE, 01 refer. The above table is in accordance with Table 4D5 of the 17th Edition of IEE Wiring Regulations. The Current Carrying Capacities in this appendix are based upon the following reference ambient temperatures: For non-sheathed and sheathed cables in air, irrespective of the Installation Method: 30ºC For buried cables, either directly in the soil or in ducts in the ground: ºC The current ratings stated are based on conservative assumptions, and therefore, in some instances, may be adjusted according to the ambient installation and operating conditions.

8 Electrical Cable Product Group Control Flexible YY Control Flexible Cable Used as interconnecting cable for measuring, controlling or regulation in control equipment for assembly and production lines, conveyors and for computer units. Suitable for fixed installations or for flexible use in conditions of light mechanical stress. Can be used outdoors when protected, and in dry or moist conditions indoors. Generally to BS6500, VDE050 Class 5 flexible plain copper conductors to BS EN 608:05 (previously BS6360), VDE095 PVC (Polyvinyl Chloride) Type YI Sheath PVC (Polyvinyl Chloride) Type YM Sheath Colour Grey 300/500V Fixed: -35 C to + 70 C Flexing: -5 C to + 70 C Minimum Bending Radius 10 x overall diameter Core Identification Black with White numbers (3 cores and above includes Green/Yellow) Coloured cores available No. of Cores x Nominal Cross Sectional Area # x ² YY Control Flexible Cable - Cores Nominal Overall Diameter kg/ Km FCGA/AP Gland A5Y0050 x /S A5Y0075 x /S A5Y010 x /S A5Y015 x /S A5Y05 x / YY Control Flexible Cable - 3 Cores A5Y x /S A5Y x /S A5Y x /S A5Y x /S A5Y x / A5Y x S/ A5Y x S/ A5Y x /5 A5Y x /3 YY Control Flexible Cable - 4 Cores A5Y x /S A5Y x /S A5Y x /S A5Y x / A5Y x S/ A5Y x S/ A5Y x /5 A5Y x /5 A5Y x /3 A5Y045 4 x /3 YY Control Flexible Cable - 5 Cores A5Y x /S A5Y x /S A5Y x /S A5Y x / A5Y x S/ A5Y x / A5Y x /5 A5Y x /5 A5Y x /3 A5Y055 5 x /40 A5Y x /40 YY Control Flexible Cable - 6 Cores A5Y x /S A5Y x / YY Control Flexible Cable - 7 Cores A5Y x /S A5Y x / A5Y x / A5Y x S/ A5Y x S/ YY Control Flexible Cable - 8 Cores A5Y x / A5Y x S/ A5Y x S/

9 Electrical Cable Product Group Mains Armoured SWA Cable - BS5467 Steel Wire Armoured PVC SWA Cable - power and auxiliary control cables for use in power networks, underground, outdoor and indoor applications and for use in cable ducting. BS5467, IEC 6050 Class plain stranded copper conductor to BS EN 608:05 (previously BS6360) XLPE (Cross-Linked Polyethylene) Bedding PVC (Polyvinyl Chloride) Armouring BS5467 XLPE/PVC/AWA/PVC (Copper) No. of Cores x Nominal Cross Sectional Area # x ² Nominal Thickness of AWA Cable - BS5467 Aluminium Wire Armoured PVC - 1 Core Under Armour Nominal Diameter Overall A9AWA150 1 x A9AWA170 1 x A9AWA195 1 x A9AWA11 1 x A9AWA x A9AWA x A9AWA140 1 x A9AWA x A9AWA x A9AWA x A9AWA x Multi-Core: SWA (Steel Wire Armour) Sheath PVC (Polyvinyl Chloride) Sheath Colour Black 600/1000V 0 C to +90 C Minimum Bending Radius : 6 x overall diameter 5 and above: 8 x overall diameter Core Identification 1 Core: Brown Cores: Brown, Blue 3 Cores: Brown, Black, Grey 4 Cores: Blue, Brown, Black, Grey 5 Cores: Green/Yellow, Blue, Brown, Black, Grey Alternative core identification: White cores with Black numbers BS5467 XLPE/PVC/SWA/PVC (Copper) No. of Cores x Nominal Cross Sectional Area # x ² Nominal Thickness of SWA Cable - BS5467 Steel Wire Armoured PVC - Cores Under Armour Nominal Diameter Overall A9SWA15 x A9SWA5 x A9SWA40 x A9SWA60 x A9SWA10 x A9SWA16 x A9SWA5 x A9SWA35 x A9SWA50 x A9SWA70 x A9SWA95 x A9SWA150 x SWA Cable - BS5467 Steel Wire Armoured PVC - 3 Cores A9SWA x A9SWA305 3 x A9SWA x A9SWA x A9SWA310 3 x A9SWA316 3 x A9SWA35 3 x A9SWA335 3 x A9SWA350 3 x A9SWA370 3 x A9SWA395 3 x SWA Cable - BS5467 Steel Wire Armoured PVC - 4 Cores A9SWA x A9SWA405 4 x A9SWA x A9SWA x A9SWA410 4 x A9SWA416 4 x A9SWA45 4 x A9SWA435 4 x A9SWA0 4 x A9SWA470 4 x A9SWA495 4 x A9SWA41 4 x A9SWA x A9SWA x A9SWA440 4 x

10 LR Thermal Relay LR-D13 LR-D3 LR-D A LR-D A This series of thermal relay can be used in the circuit of 50Hz or 60Hz, rated insulation voltage 660V, rated current A for protecting the phase break when the electric motor is overload. The relay has different mechanism and temperature compensation, and it can be plugged in L C1-D seri es AC Contactor. At present, it is the most advanced thermal relay in the world. Characteristics a. Fundamental parameter of the main circuit (a).rated insulation voltage 660V. (b).rated working current 5, 36, 93A separately (c).the regulator seal of rated setting current. (D).Current of the thermal component(see list 1) b. Auxiliary Circuit (a).there are one pair of N/O and N/C contract with electric insulation Specifications (b).rated insulation Voltage 500V. (C). Rated frequency 50-60Hz. (D).Use group, rated working voltage, appoint thermal current and rated current.

11 CJX(LC1-D)AC Contactor CJX-09(LC1-D09) CJX-1(LC1-D1) CJX-18(LC1-D18) CJX-5(LC1-D5) CJX-3(LC1-D3) CJX-40(LC1-D40) CJX series AC Contactor is suitable for using in the circuits the rated voltage up to 660V AC 50Hz or 60 Hz, rated current up to 95A, for making & breaking, frequently starting & controlling the AC motor. Combined with the auxiliary contact block, timer delay & machine- interlocking device etc, it becomes the delay co nt ac to r, mechanical interlocking contactor, star-delta starter. With the thermal relay, it is combined into the electromagnetic starter. The Contactor is produced according to IEC , GB CJX-50(LC1-D50) CJX-65(LC1-D65) CJX-80(LC1-D80) CJX-95(LC1-D95) New type CJX-18N(LC1-D18N) New type CJX-3N(LC1-D3N) Standard control circuit voltages Volts Hz 60Hz 50/60Hz B5 B6 B7 D5 D6 D7 E5 E6 E7 F5 F6 F7 M5 M6 M7 P5 - P7 U5 U6 U7 Q5 Q6 Q7 V5 V7 N5 N7 R5 R6 R7 S5 Y5 Specifications Type Rated working current (A) AC3 capacity of three-phase squirrel-cage motor AC3(KW) AC3 AC4 /30V 380/400V 415V 440V 500V 660/690V Rated heat current(a) 4 AC4 10 Electrical life 6 AC Mechanical life 10 Number of the contact CJX-09 (LC1-D09) CJX-1 (LC1-D1) CJX-18 (LC1-D18) CJX-5 (LC1-D5) CJX-3 (LC1-D3) P+NO 3P+NC CJX-40 (LC1-D40) CJX-50 (LC1-D50) CJX-65 (LC1-D65) CJX-80 (LC1-D80) CJX-95 (LC1-D95)

12 TRADITIONAL CONCRETE MIXERS Dati tecnici/ Te chnical datas Capacità bicchiere / Drum capacity MOD. S 150 TIPO S 97 LT. 140 MOD. S 0 TIPO S 9 LT. 190 MOD. S 50 TIPO S 94 LT. 4 MOD. S 3 TIPO S 75 LT. 31 MOD. S 360 TIPO S 75 I LT. 355 Capacità utile / Work capacity Lt. 110 Lt. 160 Lt. 5 Lt. 75 Lt. 315 Motore elettrico / Electric motor HP 0,75 HP 0,75 HP 1-1,5 HP 1,5- HP 1,5- Motore a scoppio / Petrol engine _ HP 6 HP 6 HP 6-7 HP 6-7 Motore diesel / Diesel engine _ HP 6-9 HP 6-9 Peso con motore elettrico Weight with electric motor kg 95 kg 1 kg 170 kg kg 30 Lunghezza / Length cm 1 cm 165 cm 175 cm 198 cm 0 Larghezza / Width cm 80 cm 80 cm 96 cm 100 cm 100 Altezza / Height cm 15 cm 135 cm 1 cm 150 cm 150 Pale di mescolamento imbullonate al bicchiere ed abbinate ad uno specifico controfondo studiato per una maggiore velocità dʼesecuzione ed una migliore omogeneità dellʼimpasto. Mixing blades applied with bolts to the tray and combined to a specific counter-bottom that is helpful for a greater speed and for a more homogeneous mixing. Gruppo di ribaltamento con supporto in ghisa e corona di grandi dimensioni per ridurre al minimo la fatica ed agevolare tutte le operazioni di manutenzione. Tilting group with cast iron support and tilting plate of big dimensions to reduce to the least the effort and to facilitate the operations of maintenance.

6491B / H07Z-R / BS EN Cable

6491B / H07Z-R / BS EN Cable 6491B / H07Z-R / BS EN 50525-3-41 Cable Eland Product Group: A3Z APPLICATION Suitable for use in conduit and for fixed, protected installation. For installations where fire, smoke emission and toxic fume

More information

BS 5467 Copper Conductor Multi Core SWA PVC BASEC 0.6/1kV Cable

BS 5467 Copper Conductor Multi Core SWA PVC BASEC 0.6/1kV Cable BS 5467 Copper Conductor Multi Core SWA PVC BASEC 0.6/1kV Cable Eland Product Group: A9S APPLICATION Multi-core PVC cable with steel wire armour (SWA). Power and auxiliary control cables for use in power

More information

BS 6724 Copper Conductor Multi Core SWA LSZH BASEC 0.6/1kV Cable

BS 6724 Copper Conductor Multi Core SWA LSZH BASEC 0.6/1kV Cable ed Cable BS 6724 Copper Conductor Multi Core SWA LSZH BASEC 0.6/1kV Cable BS 6724 Copper Conductor Multi Core SWA LSZH BASEC 0.6/1kV Cable Eland Product Group: A9L APPLICATION Multi-core LSZH cable with

More information

NYY-J Cable. Dungannon Electrical Wholesale Tel: Page 1 of 10

NYY-J Cable. Dungannon Electrical Wholesale Tel: Page 1 of 10 NYY-J Cable Application: A VDE approved, solid conductor, black PVC jacketed, 600/1kV power and control cable. These power cables are designed for energy supply cable ducts, power station, industry and

More information

N2XY IEC XLPE PVC 0.6/1kV Cable

N2XY IEC XLPE PVC 0.6/1kV Cable N2XY IEC 60502-1 XLPE PVC 0.6/1kV Cable Eland Product Group: A2N APPLICATION These power and control cables are used for electricity supply in low voltage installation systems. They are well adapted to

More information

SY PVC / BS EN Control Flexible Cable

SY PVC / BS EN Control Flexible Cable SY PVC / BS EN 50525-2-51 Control Flexible Cable Eland Product Group: A5J APPLICATION Used as interconnecting cable for measuring, controlling or regulation in control equipment for assembly and production

More information

1 Conductor Class 5 flexible annealed plain copper conductor

1 Conductor Class 5 flexible annealed plain copper conductor YY Control Cable Application: YY Control is a flexible mulit-core cable with class 5 flexible annealed plain copper conductors, PVC insulation, and a grey PVC sheath. YY Cable is used in fixed installations

More information

The cables you need when you need them

The cables you need when you need them The cables you need when you need them Whether you need standard or specialist cables you re looking in the right place. With a massive range available on short lead-times we can deliver the product you

More information

Single Core Cables 51

Single Core Cables 51 Single Core Cables 51 Single Core Cables PVC PVC Single Core Cables H05V-K /H07V-K Conductors: Flexible copper (class 5) Insulation: PVC Standards: HAR CENELEC Fire Performance: Flame retardant to IEC

More information

600/1000V XLPE Insulated, LSZH Sheathed, Armoured Power Cables (2-5 Cores)

600/1000V XLPE Insulated, LSZH Sheathed, Armoured Power Cables (2-5 Cores) www.caledonian-s.co.uk www.addison-s.com 600/1000V XLPE Insulated, LSZH Sheathed, Armoured Power Cables (2-5 Cores) FTX400 1RZ1-R (CU/XLPE/LSZH 600/1000V Class 2) FTX400 1RZ1MZ1-R (CU/XLPE/LSZH/SWA/LSZH

More information

RE-T2X(st)H SWAH - BS EN Mica XLPE / LSZH / CAM / SWA / LSZH Cable

RE-T2X(st)H SWAH - BS EN Mica XLPE / LSZH / CAM / SWA / LSZH Cable RE-T2X(st)H SWAH - BS EN 50288-7 Mica XLPE / LSZH / CAM / SWA / LSZH Cable Eland Product Group: I APPLICATION These cables are designed to connect electrical instrument circuits and provide counication

More information

SY Cable. Dungannon Electrical Wholesale Tel: Page 1 of 8

SY Cable. Dungannon Electrical Wholesale Tel: Page 1 of 8 SY Cable Application: Measuring and control cable to connect equipment in production lines / assembly lines and conveyor systems. Can be used both fixed and flexible installations. Techincal Data: 1 Plain

More information

BS6724 SWA/LSZH Cable IEC /1000V

BS6724 SWA/LSZH Cable IEC /1000V BS6724 SWA/LSZH Cable IEC 60502 600/1000V Applications: Power cable suitable for power networks, where fire emission of smoke and toxic fumes creates a serious potential threat. Suitable for direct burial.

More information

BS 6724 Armoured Power Cables, 600/1000V

BS 6724 Armoured Power Cables, 600/1000V BS 6724 Armoured Power Cables, 600/1000V Application These cables are used for power and control circuits, they can offer excellent protection through the use of a heavy galvanized steel wire armour. The

More information

600/1000V XLPE Insulated PVC Sheathed Power Cables (Multicore)

600/1000V XLPE Insulated PVC Sheathed Power Cables (Multicore) 600/1000V XLPE Insulated PVC Sheathed Power Cables (Multicore) FGD400 1RV-R (CU/XLPE/PVC 600/1000V Class 2) Outdoor Cabling Earth Conductor Earth Conductor APPLICATION The cables are mainly used in power

More information

WIRES & WIRING CABLES

WIRES & WIRING CABLES WIRES & WIRING CBLES CBLES FZE www.markcables.com Index 1) Introduction................ 02 2) CU/PVC Wires 450/750 Volts Round Solid (Class 1) H07V-U......... 04 3) CU/PVC Wires 450/750 Volts - Round

More information

Firetec BS 7846 LPCB BASEC Approved Power Cable

Firetec BS 7846 LPCB BASEC Approved Power Cable Firetec BS 7846 LPCB BASEC Approved Power Cable Eland Product Group: A6F APPLICATION Firetec Power is a fire resistant armoured cable suitable for use in fixed installations for power circuits, fire alarm

More information

THE UK S BENCHMARK FOR TRI-RATED CABLE

THE UK S BENCHMARK FOR TRI-RATED CABLE THE UK S BENCHMARK FOR TRI-RATED CABLE Welcome to Clynder Cables Clynder Cables has over thirty years of experience in the supply of UK manufactured industrial electrical cables to the UK, European and

More information

PVC SHEATH FLAME RETARDANT CABLE TO IEC60332

PVC SHEATH FLAME RETARDANT CABLE TO IEC60332 600/1000V XLPE Insulated PVC Sheathed Armoured Power Cables -5 Cores CU/XLPE/PVC 600/1000V Class CU/XLPE/PVC/SWA/PVC 600/1000V Class Application: The cables are mainly used in power stations, mass transit

More information

Catalogue. Index INDUSTRIAL CABLE

Catalogue. Index INDUSTRIAL CABLE Catalogue INDUSTRIAL CABLE 1. BARE COPPER EARTH WIRE 2. GENERAL PURPOSE HOUSE WIRE 3. SURFIX CABLE 4. FLAT TWIN & EARTH CABLE 5. CABTYRE CABLE 6. TWIN ILLUMINATION CABLE 7. SINGLE CORE FLEX 8. SOLID PANEL

More information

Power & Control Cable IEC

Power & Control Cable IEC (2-, 3-, 4,- and 5-cores) U 0 Application For electricity supply and control in public networks and industrial plants; suitable for use in zone 1 and zone 2 group ΙΙ classified areas (IEC 60079-14). Recoended

More information

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (2-5 Cores)

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (2-5 Cores) www.caledonian-s.co.uk www.addison-s.com 600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (2-5 Cores) FGD400 1RV-R (CU/XLPE/PVC 600/1000V Class 2) FGD400 1RVMV-R (CU/XLPE/PVC/SWA/PVC 600/1000V

More information

FLEX-O-POWER FLEXIBLE WELDING

FLEX-O-POWER FLEXIBLE WELDING EQUIPMENT cables FLEX-O-POWER FLEXIBLE WELDING & POWER CABLE High conductivity bunched flexible annealed copper conductors, insulated with a soft flexible grade PVC suitable for welding and power purposes.

More information

Power & Control Cables. U o. /U 0.6/1 kv - IEC

Power & Control Cables. U o. /U 0.6/1 kv - IEC Power & Control Cables U o /U 0.6/1 kv - IEC 60502-1 2 KERPEN GmbH & Co. KG 07.2005 Printing errors excepted. Subject to alteration List of Contents Introduction Page B1 Construction Page B3 Use Page B4

More information

Unarmoured Single-Core Cables to BS6883

Unarmoured Single-Core Cables to BS6883 Unarmoured Single-Core Cables to BS TAC. EPR. SW 00/00 V 1 Application Unarmoured cable for use where mechanical protection is not required for fixed wiring in ships and in mobile and fixed offshore units

More information

is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire.

is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire. is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire. We are a major supplier of housewiring, low voltage, power and fire resistant cables for

More information

INTRODUCTION NUHAS OMAN QUALITY & RELIABILITY.

INTRODUCTION NUHAS OMAN QUALITY & RELIABILITY. INTRODUCTION Nuhas Oman LLC, an integral part of The Al Bahja Group of Companies, is a Quality producer of: HV, MV and LV Cables Enamelled Copper Wires Oxygen Free Continuous Cast Copper Wire Rods Drawn

More information

Power & Control Cable IEC

Power & Control Cable IEC (2-, 3-, and 4-cores) U 0 Application For electricity supply and control in public networks and industrial plants; suitable for use in zone 1 and zone 2 group ΙΙ classified areas (IEC 60079-14). Recoended

More information

FR-3S Fire Resistant Cables

FR-3S Fire Resistant Cables FR-3S Fire Resistant Cables APPLICATION This cable is suitable use in fire extinguishing systems to operate sprinklers, control panels, exit lights in high-rise buildings, hotels, hospitals, sub-ways and

More information

Technical Data Sheet Unshielded (YY) PVC Control Cable

Technical Data Sheet Unshielded (YY) PVC Control Cable Technical Data Sheet Unshielded (YY) PVC Control Cable MachFlex 350 YY VDE Registered Flexible PVC Control Cables Applications Designed for applications which are installed in occasional flexing and fixed

More information

Power & Control Cable IEC

Power & Control Cable IEC (2-, 3-, and 4-cores) U 0 PVC-Insulation, Application For electricity supply and control in public networks and industrial plants; suitable for use in zone 1 and zone 2 group ΙΙ classified areas (IEC 60079-14).

More information

Power & Control Cables

Power & Control Cables The Quality Connection Power & Control Cables U o /U 0.6/1 kv - IEC 60502-1 2 The Quality Connection www.leoni-industrial-projects.com The LEONI Group Cable expertise for the most various industrial markets.

More information

burning o Red o Black o Blue o Yellow o Brown o Grey Fire Performance BS EN

burning o Red o Black o Blue o Yellow o Brown o Grey Fire Performance BS EN LSOH Wiring Cables Low Voltage (/7 V) LSOH Conduit Wire (HO7ZR) 91B Cable Approvals Cable approved to BS711 Key Applications > Installation in surface mounted or embedded conduits, or similar closed systems

More information

Technical Data Sheet Unshielded (YY) PVC Control Cable

Technical Data Sheet Unshielded (YY) PVC Control Cable MachineTuff Cables Applications Designed for applications which are installed in occasional flexing and fixed locations. Cable applications include precision control sensors, multi axis control machines,

More information

PRODUCT INFORMATION H07V-K

PRODUCT INFORMATION H07V-K GmbH PRODUCT INFORMATION European cable type certification Cables' marking also stands for the international endorsement of national certification institutes' testing marks and certificates,

More information

Materials Evolved* BS EN BS EN IEC IEC (Upon customer request) (Red, Black) or (Brown, Blue)

Materials Evolved* BS EN BS EN IEC IEC (Upon customer request) (Red, Black) or (Brown, Blue) XLPE INSULATED AND PVC OR LOW SMOKE HALOGEN FREE (LSHF) SHEATHED CABLES Voltage Rating (Uo/U) : 00/00V, 1/0V or 00/3V Standards Complied Main Specification Materials Test Methods Flame Retardant Test Test

More information

PROTEC. Screened Wiring Cable. Updated to meet new requirements of BS 8436:2011 BASEC approved.

PROTEC. Screened Wiring Cable. Updated to meet new requirements of BS 8436:2011 BASEC approved. PROTEC Screened Wiring Cable Updated to meet new requirements of BS 8436:2011 BASEC approved www.aeicables.co.uk PROTEC CABLES Manufactured and designed to BS 8436 and IS 273 Protec Low Smoke Zero Halogen

More information

flame Retardant overall screened Instrumentation cables (Multicore)

flame Retardant overall screened Instrumentation cables (Multicore) Caledonian flame Retardant Instrumentation cables www.caledonian-cables.co.uk www.addison-cables.com flame Retardant overall screened Instrumentation cables (Multicore) Re-2X(st)y Re-2X(st)ysWay PVC Outer

More information

o o blue-brown Fire Performance BS EN BS EN

o o blue-brown Fire Performance BS EN BS EN Standard Power Cables Low age (600/1000 V) Afumex 90 Armoured Power Cable Cable Approvals > Cable approved to BS6724 > Plain annealed copper stranded (Class 2) for ease of handling Insulation > 90 C -linked

More information

Building & Infrastructure Cables DELIVERING ENERGY

Building & Infrastructure Cables DELIVERING ENERGY Building & Infrastructure Cables DELIVERING ENERGY Keystone Cable is a Leading Singaporebased Cable Manufacturer and Supplier. Keystone Cable Market Reach Established since 1990, Keystone Cable has an

More information

Flame Retardant Individual and Overall Screened, Armoured Instrumentation Cables (Multipair)

Flame Retardant Individual and Overall Screened, Armoured Instrumentation Cables (Multipair) Caledonian Flame Retardant Instrumentation Cables www.caledonian-cables.co.uk www.addison-cables.com Flame Retardant Individual and Overall Screened, Armoured Instrumentation Cables (Multipair) RE-2X(st)YSWAY

More information

PRODUCT INFORMATION. ÖLFLEX HEAT 180 SiF

PRODUCT INFORMATION. ÖLFLEX HEAT 180 SiF GmbH PRODUCT INFORMATION Versatile stranded conductors with extended temperature range Halogen-free Temperature-resistant Info Flexible fine-wire copper conductor Application range Areas with high ambient

More information

PRODUCT INFORMATION MULTI-STANDARD SC 2.1. U.I. Lapp GmbH

PRODUCT INFORMATION MULTI-STANDARD SC 2.1. U.I. Lapp GmbH GmbH PRODUCT INFORMATION USA: UL-listed (MTW), Canada: CSA (TEW), Europe: H07V-K (depending on cross s.), tin-coated strands For use in the most important global markets Reduction in technical documentation

More information

Your Partner in Safe Power Solutions. About RESCAB

Your Partner in Safe Power Solutions. About RESCAB Your Partner in Safe Power Solutions About RESCAB Red Sea Cables Company (RESCAB) was established as a closed joint stock company in 2008 in the Kingdom of Saudi Arabia with a capital of 370 million SAR.

More information

YOUR ENERGY, OUR SYSTEMS, ANYWHERE. Flexible Cables

YOUR ENERGY, OUR SYSTEMS, ANYWHERE. Flexible Cables YOUR ENERGY, OUR SYSTEMS, ANYWHERE Flexible Cables 2010 FLEXIBLE CABLES PRYSMIAN TECHNICAL MANUALS COMMUNICATION CONSTRUCTION DATA & INSTRUMENTATION FIBRE TO THE PREMISES FIRE PERFORMANCE FLEXIBLE CABLES

More information

PRODUCT INFORMATION. ÖLFLEX HEAT 180 SiF. Info Flexible fine-wire copper conductor

PRODUCT INFORMATION. ÖLFLEX HEAT 180 SiF. Info Flexible fine-wire copper conductor Versatile single core cable with extended temperature range - fine wire silicone single core for use in machines, plant construction and toolbuilding for temperatures up to +180 C Info Flexible fine-wire

More information

Controlflex Cables Controlflex Cables

Controlflex Cables Controlflex Cables YY Type Cable.............................: CY Type Cable..............................: YCY-JZ Transparent PVC Sheath...............: SY Type Cable.............................:1 YY-LSF Type Cables.........................:1

More information

HIGH TEMPERATURE CABLES

HIGH TEMPERATURE CABLES HIGH TEMPERATURE CABLES C O N T E N T S DEF 61-12 Part 18 Type 1 LFH Equipment Wires :2 Technical Information for DEF 61-12 :8 PTFE Insulated Equipment Wire Single Core :10 PTFE EFGLAS Aircraft Cable :12

More information

LSZH Fire Resistant Cables

LSZH Fire Resistant Cables 300/500V Single-Core ~ 4-Core Mica Tape Fire Barrier, XLPE Insulated, LSZH Sheathed, Fire Resistant Cable CU/MICA/XLPE/LSZH of the electrical circuit is critical in maintaining power supply. Applications

More information

Technical Data Sheet Shielded (CY) PVC Control Cable

Technical Data Sheet Shielded (CY) PVC Control Cable MachineTuff Cables Tinned Copper Braid Shield (TCB) Excellent Noise Immunity Applications Designed for applications which are installed in occasional flexing and fixed locations. Cable applications include

More information

600/1000V, XLPE Insulated Cables according to IEC

600/1000V, XLPE Insulated Cables according to IEC 600/1000V, XLPE Insulated Cables according to IEC 60502-1 Single core(unarmoured) Two core(unarmoured) Three core(unarmoured) Three core +1(unarmoured) Four core(unarmoured) Multi- core(unarmoured) Single

More information

VDE tested single cores according to EN (H05Z-K & H07Z-K) for more demanding requirements

VDE tested single cores according to EN (H05Z-K & H07Z-K) for more demanding requirements VDE tested single cores according to EN 50525-3-41 (H05Z-K & H07Z-K) for more demanding requirements ÖLFLEX HEAT 125 C MC - halogen free single core with GL certificate, special fire performance, IEC 60332-3,

More information

Technical Data Sheet Shielded (CY) PVC Control Cable

Technical Data Sheet Shielded (CY) PVC Control Cable Technical Data Sheet Shielded (CY) PVC Control Cable MachFlex 350 CY VDE Registered Tinned Copper Braid Shield (TCB) Excellent Noise Immunity Applications Designed for applications which are installed

More information

NA2XSEKRY 3 x (25-300) mm² 3.6/6 kv

NA2XSEKRY 3 x (25-300) mm² 3.6/6 kv NA2XSEKRY 3 x (25-300) mm² 3.6/6 kv NA2XSEKRY 3 x (25-300) mm² 3.6/6 kv (Aluminium, XLPE Insulated, Copper Tape, Lead Sheathed,, PVC Sheathed) 25 47.5 5,292 35 50.5 5,960 50 53.5 6,694 70 58.5 7,816 95

More information

Caledonian Medium Voltage Cables Three Core Cables to VDE 0276-

Caledonian Medium Voltage Cables Three Core Cables to VDE 0276- Three Core Cables to VDE 0276 APPLICATIONS The three core cables are designed for distribution of electrical power with nominal voltage Uo/U ranging from 3.6/6.6KV to 19/33KV and frequency 50Hz. They are

More information

600/1000V, PVC Insulated Cables according to IEC

600/1000V, PVC Insulated Cables according to IEC 8 Any inquiries, please feel free to contact 600/1000V, PVC Insulated s according to IEC 60502-1 Single core(unarmoured) Two core(unarmoured) Three core(unarmoured) Three core +1(unarmoured) Four core(unarmoured)

More information

Caledonian Fire Resistant Optic Fiber Cables

Caledonian Fire Resistant Optic Fiber Cables Fire Resistant Optic Cables Fire resistant Central Loose Optic cables Application These cables are characterized by light weight and small diameter, suitable for both aerial and duct installation. They

More information

NA2XSEKY 3 x (25-300) mm² 3.6/6 kv

NA2XSEKY 3 x (25-300) mm² 3.6/6 kv NA2XSEKY 3 x (25-300) mm² 3.6/6 kv NA2XSEKY 3 x (25-300) mm² 3.6/6 kv (Aluminium, XLPE Insulated, Copper Tape, Lead Sheathed, PVC Sheathed) 25 39.5 3,292 35 43.0 3,824 50 46.0 4,419 70 50.5 5,264 95 54.5

More information

LOW VOLTAGE c a b l e s

LOW VOLTAGE c a b l e s LOW VOLTAGE c a b l e s MYSORE PLANT SILVASSA PLANT MANUFACTURES A RANGE OF LOW VOLTAGE CABLES AT ITS FACILITIES AT SILVASSA AND MYSORE The Silvassa unit manufactures LV Cables since the year 2000. XLPE/

More information

Insulation Colours: Orange (Standard) Natural Natural. Sheath Colours: Orange (Standard) Orange (Standard) Bedding: Black

Insulation Colours: Orange (Standard) Natural Natural. Sheath Colours: Orange (Standard) Orange (Standard) Bedding: Black -I Insulated, non-sheathed Insulated and sheathed Insulated, ed and sheathed 1. : Plain stranded annealed Class 2 Copper. 1.5mm 2 up to 630mm 2 Plain stranded annealed Class 2 Copper. Plain stranded annealed

More information

MOTOR, SERVO, & FEEDBACK CABLES

MOTOR, SERVO, & FEEDBACK CABLES MOTOR, SERVO, & FEEDBACK CABLES Motor, servo, and feedback cables Temperature ( C) - flexing Temperature ( C) - fixed Nominal voltage U 0 /U Bending radius - flexing x Ø Bending radius - fixed x Ø Halogen-free

More information

Electronic Instrumentation

Electronic Instrumentation Applications Electronic instrumentation, analog and digital signal circuits (4-20mA). Intrinsically safe circuits. Gas and/or fluid leak detection systems. Pressure, temperature and volume measuring and

More information

Calculation of the Cross-sectional Areas of Circuit Live Conductors

Calculation of the Cross-sectional Areas of Circuit Live Conductors Calculation of the Cross-sectional Areas of Circuit Live Conductors MOTOR CIRCUITS SUBJECT TO FREQUENT STOPPING AND STARTING Regulations requires that where a motor is intended for intermittent duty and

More information

TC-RHH/RHW-2 USE-2 Copper

TC-RHH/RHW-2 USE-2 Copper TC-RHH/RHW-2 USE-2 Copper XLPE Insulated, PVC Jacketed, ER; 600 V Features Standards UL Listed as TC-ER - exposed run tray cable. Jacket is rated Sunlight Resistance, Oil Resistance I and Direct Burial.

More information

Technical Data Sheet Shielded (CY) PVC Control Cable

Technical Data Sheet Shielded (CY) PVC Control Cable Technical Data Sheet Shielded (CY) PVC Control Cable MachFlex 375 CY Tinned Copper Braid Shield (TCB) Excellent Noise Immunity Applications Designed for applications which are installed in occasional flexing

More information

Caledonian. BS 6346 PVC Insulated, Armored Power and Control Cables. Addison.

Caledonian. BS 6346 PVC Insulated, Armored Power and Control Cables. Addison. Caledonian BS 6346 PVC Insulated, Armored Power and Control Cables www.caledonian-s.co.uk www.caledonian-s.com Addison Company Profile Caledonian. established in 1978.offers one of the most complete lines

More information

BS EN Natural. (Orange for Non-sheathed) (Red & Black) or (Brown & Blue) (Red, Yellow, Blue) or (Brown, Black, Grey)

BS EN Natural. (Orange for Non-sheathed) (Red & Black) or (Brown & Blue) (Red, Yellow, Blue) or (Brown, Black, Grey) LOW SMOKE HALOGEN FREE (LSHF) FIRE RESISTANT CABLES Voltage Rating (Uo/U) : /0V, /7V or 00/00V Standards Complied Main Specification Fire Tests Flame Retardant Test Test on Acid Gas Evolved Smoke Density

More information

BASEC approved to BS8436 (300/500V) and IS273 (600/1000V) THE ORIGINA L BS8436 CABLE

BASEC approved to BS8436 (300/500V) and IS273 (600/1000V) THE ORIGINA L BS8436 CABLE BRITISH APPROVALS SERVICE FOR CABLES BASEC approved to BS8436 (300/500V) and IS273 (600/1000V) BASEC THE ORIGINA L BS8436 CABLE BASEC approved cables Launched in 2004 Flexishield has become the leading

More information

Introduction. Nexans wire and cable. Contact us for all your wire and cable needs

Introduction. Nexans wire and cable. Contact us for all your wire and cable needs Introduction Nexans is one of the largest wire and cable manufacturers in the world, and in North America. In North America we manufacture in locations across the United States and Canada. We design and

More information

Telephone Cables Fire Warning Cables

Telephone Cables Fire Warning Cables Telephone Cables Fire Warning Cables Telephone Cables Fire Warning Cables As supplier of underground cables, telephone cables for indoor and outdoor lying, as well as fire warning cables (also the halogen-free

More information

PRODUCT CATALOGUE Volume 4

PRODUCT CATALOGUE Volume 4 PRODUCT CATALOGUE Volume 4 Tel: +27(11) 864 1606 Main Fax: +27(11) 864 8294 E-mail: yasmin@soew.co.za Admin Fax: +27(11) 908 6439 Website: www.soew.co.za Agent - Durban Congella Cables cc 21 Canada Road

More information

Caledonian Medium Voltage Cables

Caledonian Medium Voltage Cables Three Core Cables to VDE 0276 APPLICATIONS: The three core cables are designed for distribution of electrical power with nominal voltage Uo/U ranging from 3.6/6.6KV to 19/33KV and frequency 50Hz. They

More information

Caledonian Medium Voltage Cables

Caledonian Medium Voltage Cables Three Core Cables to VDE 0276 APPLICATIONS: The three core cables are designed for distribution of electrical power with nominal voltage Uo/U ranging from 3.6/6.6KV to 19/33KV and frequency 50Hz. They

More information

NA2XSEY 3 x (25-300) mm 2 3.6/6 kv

NA2XSEY 3 x (25-300) mm 2 3.6/6 kv NA2XSEY 3 x (25-300) mm 2 3.6/6 kv NA2XSEY 3 x (25-300) mm 2 3.6/6 kv (Aluminium, XLPE Insulated, Copper Tape, PVC Sheathed) 25 36.5 1,380 35 39.5 1,620 50 42.0 1,908 70 46.5 2,322 95 50.0 2,781 120 54.0

More information

FR-N1X1G1. Low voltage - Energy, cabling, signalling and control

FR-N1X1G1. Low voltage - Energy, cabling, signalling and control Low voltage - Energy, cabling, signalling and control FR-N1X1G1 Construction: NF C 32-323 NF C 32-323/1 Fire propagation: NF EN 60332-3-24 NF C 32-070 C1 IEC 60332-3-24 C Flame propagation: NF EN 60332-1-2

More information

H05 V-K PVC-Single Cores, fine wire stranded

H05 V-K PVC-Single Cores, fine wire stranded H05 VK PVCSingle Cores, fine wire stranded Technical data PVC single cores to DINVDE0283 H05 VK/H05 VU to DINVDE028 part3, HD2.3S3 and IEC02273 Temperature range flexing 5 C to +70 C fixed installation

More information

BASEC approved to BS8436 (300/500V) and IS273 (600/1000V) THE ORIGINA L BS8436 CABLE

BASEC approved to BS8436 (300/500V) and IS273 (600/1000V) THE ORIGINA L BS8436 CABLE BASEC approved to BS8436 (300/500V) and IS273 (600/1000V) BRITISH APPROVALS SERVICE FOR CABLES BASEC THE ORIGINA L BS8436 CABLE BASEC approved cables Launched in 2004 Flexishield has become the leading

More information

About us. Switchgear Factory, Mumbai

About us. Switchgear Factory, Mumbai Wires & Cables About us Larsen & Toubro is a technologydriven USD 9.8 billion company that infuses engineering with imagination. The Company offers a wide range of advanced solutions in the field of Engineering,

More information

SPECIFICATION S VR 1(4) HALOGEN FREE POWER AND CONTROL CABLE FOR MARINE APPLICATIONS LM-HF 0,6/1 kv and TEMAR PHFX-U 0,6/1 kv APPLICATI

SPECIFICATION S VR 1(4) HALOGEN FREE POWER AND CONTROL CABLE FOR MARINE APPLICATIONS LM-HF 0,6/1 kv and TEMAR PHFX-U 0,6/1 kv APPLICATI 1(4) HALOGEN FREE POWER AND CONTROL CABLE FOR MARINE APPLICATIONS LM-HF 0,6/1 kv and TEMAR PHFX-U 0,6/1 kv APPLICATION Power and control cable for fixed installations. Designed to fulfill requirements

More information

USA: UL-listed (MTW), Canada: CSA (TEW), Europe: <HAR> H07V-K (depending on cross s.), tin-coated strands

USA: UL-listed (MTW), Canada: CSA (TEW), Europe: <HAR> H07V-K (depending on cross s.), tin-coated strands USA: UL-listed (MTW), Canada: CSA (TEW), Europe: H07V-K (depending on cross s.), tin-coated strands Lapp Kabel, power and control cable, PVC single core for field wiring, UL MTW VW-1, UL AWM style

More information

600/1000 V. 5. Flame Retardancy VDE , DIN EN , IEC

600/1000 V. 5. Flame Retardancy VDE , DIN EN , IEC MachineTuff Cables Low Voltage Control & Power Cable Galvanized Steel Wire Braid Armored (GSWB) > Excellent Mechanical Protection Applications Designed for applications which are installed in occasional

More information

SY Type Control Cable 0.5mm 2 to 120mm 2 PVC Sheath

SY Type Control Cable 0.5mm 2 to 120mm 2 PVC Sheath Applications Control cables in tool machinery, plant installation, power stations and data equipment. The braided screen of the galvanized steel wires offers the best possible protection against mechanical

More information

Solid PE Insulated & LAP Sheathed Air Core/Jelly Filled Cables to DIN VDE 0816

Solid PE Insulated & LAP Sheathed Air Core/Jelly Filled Cables to DIN VDE 0816 Solid PE Insulated & LAP Sheathed Air Core/Jelly Filled Cables to DIN VDE 0816 APPLICATION The cables are designed for use as connection between central fices. The cables are suitable for installation

More information

DRILL CORD. Insulation Nominal Size. Approximate Amps Anixter. Number Number Thickness O.D.

DRILL CORD. Insulation Nominal Size. Approximate Amps Anixter. Number Number Thickness O.D. DRILL CORD Synthetic Rubber Insulation 75 C, 600 Volts For use on drills and other mining equipment. For use on circuits not exceeding 600 volts at a maximum conductor temperature 75 C. 1. CONDUCTOR: Flexible,

More information

(N)SSHÖU O/J, (N)SSHÖU 3E, (N)SSHÖU 3E + ST 0.6/1kV Cable

(N)SSHÖU O/J, (N)SSHÖU 3E, (N)SSHÖU 3E + ST 0.6/1kV Cable ()SSHÖU O/J, ()SSHÖU 3E, ()SSHÖU 3E + ST 0.6/1kV Cable Eland Product Group: A7JS APPLICATIO Heavy duty tough rubber flexible cable with or without individually earth screened cores for dynamic or static

More information

ELECTRICAL INSPECTOR EXAMINATION 18 November 2017 QUESTION AND ANSWER BOOKLET Time Allowed: Three hours

ELECTRICAL INSPECTOR EXAMINATION 18 November 2017 QUESTION AND ANSWER BOOKLET Time Allowed: Three hours Candidate Code No. IT 36 For Board Use Only Result Date Int Result Date Int ELECTRICAL INSPECTOR EXAMINATION 18 November 2017 QUESTION AND ANSWER BOOKLET Time Allowed: Three hours INSTRUCTIONS READ CAREFULLY

More information

Corflex. Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables. Introduction Applications... 3

Corflex. Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables. Introduction Applications... 3 Corflex Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables Introduction................................. 2 Applications................................. 3 Corflex PL 300V Instrumentation

More information

On_Disc. 2 o/c1 BS 7671 applies to a lift installations b highway equipment c equipment on board ships d electrical equipment of machines.

On_Disc. 2 o/c1 BS 7671 applies to a lift installations b highway equipment c equipment on board ships d electrical equipment of machines. 1 PAPER 4 Sample Questions - C&G 2382 17th Edition full paper D 1 o/c 1 - A recommendation for the interval to the first periodic inspection shall be made by: a the installation electrician. b the main

More information

H07RN-F TITANEX PREMIUM

H07RN-F TITANEX PREMIUM New generation of flexible cables elastomer H07RN-F, born to release you from all the constraints. Thanks to its specific technology, it includes the properties of H07RN8-F; H07BN4-F; H07BB-F. Description

More information

CRANE, CONVEYOR, LIFT & REELING CABLES

CRANE, CONVEYOR, LIFT & REELING CABLES CRANE, CONVEYOR, LIFT & REELING CABLES F-PVC Series... 158 F-TPECY Series...160 P Series...161 PR Series...162 PRRT Series... 164 PRVS Series...166 Reeling/Trailing Cable Enquiry Form...168 P: (09) 264

More information

FlexFlame BFOU-XFR(i) 150/250(300)V Instr. cable. Standards applied. IEC EN 50200:2006 Annex E

FlexFlame BFOU-XFR(i) 150/250(300)V Instr. cable. Standards applied. IEC EN 50200:2006 Annex E Page 1 of 5 extended Fire Resistant, flame retardant halogen-free instrumentation cable. Mud resistant BFOU-XFR(i) 150/250(300)V MGT/EPR/EPR/TCWB/EVA Operating temperature : 90 C Operating Voltage : 150/250(300)V

More information

Chemical resistance Accidental

Chemical resistance Accidental Industrial flexible cable, insulation and outer sheath in elastomer. Oil resistant, flame retardant according to IEC/EN 60332-1-2 standard. Description Application flexible cable is intended for installations

More information

BFOU 0.6/1kV Power Cable

BFOU 0.6/1kV Power Cable BFOU 0.6/1kV Power Cable Eland Product Group: ASH APPLICATION A flame resistant, fire retardant, halogen free cable for fixed installation in various electromechanical and electric equipment, emergency

More information

AFTER GAZETTING (WORKING DOCUMENT FOR A 3 YEAR PERIOD) DATE PAGE PARAGRAPH DESCRIPTION ORIGINATOR APPROVED

AFTER GAZETTING (WORKING DOCUMENT FOR A 3 YEAR PERIOD) DATE PAGE PARAGRAPH DESCRIPTION ORIGINATOR APPROVED PART B-07 TITLE: SERVICE CONNECTIONS SPECIFICTION NO: B-07 INCEPTION DATE: AFTER GAZETTING (WORKING DOCUMENT FOR A 3 YEAR PERIOD) AMENDMENTS / REVISIONS DATE PAGE PARAGRAPH DESCRIPTION ORIGINATOR APPROVED

More information

Generator Fire Safety: Generator assemblies should be located outside the building.

Generator Fire Safety: Generator assemblies should be located outside the building. SECTION 33 70 00 - ELECTRICAL DISTRIBUTION PACKAGED GENERATOR ASSEMBLIES Generator Fire Safety: Generator assemblies should be located outside the building. All fuel piping from the outside of the building

More information

20 HUBER+SUHNER RADOX SOLAR

20 HUBER+SUHNER RADOX SOLAR All our cables fully comply with the European directives 76/769/EWG, 2003/11/EG, 2000/53/EG, 2003/53/EG and 2002/95/EG (RoHS) and the requirements of REACH Nr. EC1907/2006. 20 RADOX SOLAR cables RADOX

More information

CONDUCTOR Plain bright annealed copper! alluminium, solid! stranded conductor confirming to IS: 8130: INSULATION INNER SHEATH

CONDUCTOR Plain bright annealed copper! alluminium, solid! stranded conductor confirming to IS: 8130: INSULATION INNER SHEATH c A B L E 5 [B) Techno Flex manufacture high quality heavy duty power cable confirming to IS: 1554 (Part -1) L.T. 1100 volts grade CONSTRUCTION DETAILS:- Power Cable CONDUCTOR Plain bright annealed copper!

More information

Conductor: plain wire, fine stranding as per VDE 0295 class 6 from 50 mm² fine stranding according to VDE 0295 class 5

Conductor: plain wire, fine stranding as per VDE 0295 class 6 from 50 mm² fine stranding according to VDE 0295 class 5 Semoflex DRUM Description Application In dry and damp rooms, explosive security areas and also outdoors for heavy-duty units such as hoisting gears, transportation systems, motorized cable reels, rail

More information

cmi XLPE Cables PRODUCT CATALOGUE Electric Wire & Cables Complies to AS/NZ Standard cmi XLPE Cables

cmi XLPE Cables PRODUCT CATALOGUE Electric Wire & Cables Complies to AS/NZ Standard cmi XLPE Cables cmi XLPE s PRODUCT CATALOGUE Electric Wire & s Complies to AS/NZ Standard cmi XLPE s www.cmielectrical.com.au A division of CMI Operions Pty Ltd ABN 87 088 279 270 For over 15 years XLPE s has provided

More information

Our annual production capacity is 3000 tons for copper and 4000 tons for PVC.

Our annual production capacity is 3000 tons for copper and 4000 tons for PVC. Elki Cable is one of Turkey's leading companies in its sector and produces cables in accordance with international quality standards. Elki Cable has been founded in 983 and since 986, it has been producing

More information