AIR COMPRESSORS, VACUUM PUMPS & LIQUID PUMPS

Size: px
Start display at page:

Download "AIR COMPRESSORS, VACUUM PUMPS & LIQUID PUMPS"

Transcription

1 Lk1e Linear-motor-driven Free Piston Pumps and other Pumps for various applications AIR COMPRESSORS, VACUUM PUMPS & LIQUID PUMPS GENERAL CATALOG

2 Our air compressors and vacuum pumps are unique products featuring a Linear-motor-driven Free Piston System. Nitto Kohki has made available a complete series of air compressors and vacuum pumps that incorporate this revolutionary mechanism. These are quite appropriate as air sources or vacuum units for various pneumatically operated equipment and apparatus in advanced industries. Linear-motor-driven Free Piston Mechanism The Electro-magnet and return spring alternatively drive the piston inside the cylinder, the mechanical resonance of which is synchronized with the input current cycle. In a single mechanism, the piston combines the functions of two normally independent devices; the pump and the motor. Compact Integrated Design This unique system enables the mechanical resonance of a single part. An incredibly compact, lightweight design is achieved by combining what are entirely independent functions in conventional pumps the motor and the compressor into a superior single, unified structure. Self-cooling Design Cool intake air passes over the coils to reduce and control the rise in the pump's internal temperature. As a result of this feature, it is possible to almost completely seal the unit, thus improving the suppression of internal operating noise. Overpressure Control Mechanism Should the output pressure exceed the rated value, the piston will automatically adjust to a shorter stroke. Simultaneously, power consumption will automatically reduce to prevent the motor from failing or being burnt out. 1

3 Contents The Key Design Features of the Linear-motor-driven Free Piston System How to Use This Catalog Series Selection Conversion Tables Safety Guide Page Linear Free Piston Diaphragm DC Motor Liquid Pump AC Linear Free Piston Compressor AC12 / AC21A / AC31A / AC41A / AC62 / AC91 / AC92 / AC / AC11 / AC27 / AC41A / AC61 / AC61A / AC91 / AC92 AC Linear Free Piston Pump VP12 / VP14 / VP43A / VP4 / VP62 / VP66 / VP92A / VP94 / VP94T / VP64 / VP94 / VP66 x 2 DC Linear Free Piston Compressor DAH12-X1 / DAH12-Y1 / DAH-X1 / DAH-Y1 / DAH11-X1 / DAH11-Y1 DC Linear Free Piston Pump DVH13-X1 / DVH13-Y1 / DVH14-X1 / DVH14-Y1 AC Linear Diaphragm Pump Dual & Blower Type : VC1 / VC11 / VC11E / VC11S / VC21B / VC31B Pump: VCK12 DC Diaphragm Pump DC Piston Pump DP12 / DP14 / DP12 / DP12S / DP12H-X1 / DP12H-X2 / DP-X1 / DP-Y1 / DPA-X1 / DPA-Y1 / DP11-X1 / DP11-Y1 / DP11-X3 / DP11T-X1 / DP11T-Y1 / DP21T-X1 / DP21T-Y1 / DP41-X1 / DP41-Y1 / DP41-X2 / DP41-Y2 / DP41T-Y1 / DP41T-Y2 Piezoelectric Pump BPS / BPH / BPHS/ BPF Type DC Diaphragm Liquid Pump DPE-1 / DPE-4 / DPE-4BL / DPE-8 AC Linear Free Piston Blower LA-28B / LA-4C / LA-6B / LA-8B / LA-1A / LA-12A / LAM- / LAM-2 Linicon ( Pump) LV-12A and Pen Assembly "Cuplas" Quick Connect Couplings 11 Green Procurement Nitto Kohki has made every effort in developing Environmental Improvement Plans through the implementation of ISO141, to execute environmentally conscious business activities on a company-wide basis. As a part of our ongoing commitment to the environment, we are also committed to reduce and/or exclude restricted substances from our products as designated by RoHS directives, laws and regulations of chemical substances. 2

4 Experience gained in designing, engineering, manufacturing and continually perfecting our products in thousands of applications has resulted in a functionally intelligent package. Please review these key design features and see how every design element contributes overall to the creation of a superior compressor or vacuum pump. The Key Design Features of the Linear-motor-driven Free Piston System Compact and Lightweight with the motor and compressor combined into the single structure With the piston as the only moving part, efficient space utilization enables our pump to be considerably smaller and lighter than other pumps. This allows the OEM design engineer increased packaging options for other internal components. Low Vibration Using an ultra-lightweight piston Reducing the moving parts to only the piston minimizes reactive force vibrations to the pump body. In addition, the secondary vibrations are isolated or absorbed through the anti-vibration rubber feet. Low Noise Level No transmission assemblies, means less noise With no need for complicated transmission mechanisms riding on ball bearings, or actuating linkages creating friction and noise, Nitto Kohki s pumps are inherently quieter. Additionally, the almost completely sealed configuration further suppresses secondary internal operating noises. Clean Operation Clean Air Due to oil-less construction All wearing surfaces use no oil, grease or other contaminating lubricants. The combination of a precision fluoropolymer sleeved piston assisted by an air-bearing effect made possible through a unique air path design, assures that the outlet air is completely free of oil. Low Power Consumption Truly energy efficient through integrated design Since the low mass piston is the only moving part, frictional losses are minimized, allowing lower starting and running current, and thus greater efficiency. Related benefits are realized through a lower rise in temperature, facilitating a longer operating life for the pump and the other components within your system. Overload Protection Structure protects against burnout As the pressure within the compressor increases, the piston stroke decreases. Along with this, electric current decreases. Thus a temporary overload will not cause a failure or the pump to burnout. Minimal Pulsating Effect due to the ideal piston stroke The piston s mechanical resonance speed is synchronized with the input power frequency regardless of the load, i.e., 3 strokes at Hz, and 36 strokes at 6Hz per minute. This high speed produces shorter pulses which translate into a smoother, more uniform and linear motion. Instant Response enabling easy start-ups in frequent on-off short cycle applications A very low starting current enables our pumps to produce immediate performance in quick short cycle applications, even in the presence of residual back pressure. Easy Maintenance Only air filter and piston to change Longer Durability increased OEM value The oil-less construction requires no lubrication. A simple mechanism containing the piston as the only moving part causes no failure or burning due to an overload and provides stable performance over a long period of time. All key design features listed here combine to provide superior performance in all the important aspects of superior pump design. This enables the OEM engineer to have complete confidence in incorporating the unit into the most demanding systems, in the most advanced equipment. 3

5 Explanation of Technical Terms Be sure to read the following Explanation of Technical Terms before selecting a model appropriate for your application. and Applicable Fluids for Compressors and Pumps Application: for incorporation into equipment Applicable fluid: Air For Compressors Rated pressure: Rated airflow: Rated operation: This is the pressure point where you will get optimum capabilities for performance and service life and where the pump is designed to have almost the same airflow regardless of a rated frequency of Hz or 6Hz. The discharge airflow volume at the rated pressure. Operating conditions regarding the rated pressure, rated voltage, and rated frequency. For Compressors & Pumps Rated performance: MTTF: The average total accumulated time over which the unit can be used without repair, except the maintenance of the filter. This indicates the expected time required for the rated air flow to fall to 8% of the specification value. The actual life might vary depending on the actual operating and environmental conditions such as output pressure setting, maintenance schedule, ventilation, ambient temperature, duty cycle, etc. MTTF (Mean Time to Failure) is the average time that the product will function before it fails.however, this time is reference only and does not guarantee.since MTTF depends on your actual operating environment and conditions, conduct performance evaluation test with an actual product prior to use. Maximum pressure: Power consumption: The highest obtainable pressure at which the pump is designed to operate while producing zero discharge airflow (not guaranteed; for reference only). The wattage during operation at the rated pressure. Rated voltage: The two major types are 1V AC/6Hz and 23V AC/Hz (excluding DC motors). While most models can be operated at both Hz and 6Hz with different performance characteristics, there are some models that are frequency specific. Current: Duty cycle: The electric current during operation at the rated pressure (for reference only). The period of operation under the condition that the coil temperature will not exceed the coil insulation class limit. characteristics: -airflow curve (for reference only). Power consumption characteristics For Pumps Attainable vacuum : -power consumption curve (for reference only). The highest vacuum the pump can attain with the pump inlet closed (except some of the exclusive models). Free air displacement: The airflow volume at zero vacuum (within three (3) minutes after starting). Power consumption: Electric current: Duty cycle: The maximum wattage on the power consumption curve when measured against vacuum levels up to the pumps attainable vacuum. The maximum electric current on the current characteristics curve when measured against vacuum levels up to the pumps attainable vacuum. (for reference only). The period of operation under the condition that the coil temperature will not exceed the coil insulation class limit. characteristics: -airflow curve (for reference only). Rated frequency: Coil insulations: Control method: Outside & mounting dimensions: Operating ambient temperature: Operating ambient humidity: In the case of AC drive pumps, the rated frequency will vary according to the model. While some are designed for only Hz or for 6Hz, some are designed for both Hz and 6Hz. The suggested class, most bare units attaining E class, is based on Japanese electric regulations. They are merely suggestions since bare units are considered components and are not classified as complete products or systems. Be careful when controlling compressors and vacuum pumps with electronic components because the power factor depends upon the load. Coil Insulation Class (Temperature limit, degrees C) (for reference only) A 1 E 1 B 12 F Useful for assessing the required space for installation. Include sufficient space surrounding the pump when designing it into your application. 3 to 8% non-condensing Power consumption characteristics: Exhaust characteristics: -power consumption curve (for reference only). The time required to attain the respective vacuum in a 1 liter container (for reference only). For Liquid Pumps Self-priming pressure: For DC Pumps Operating ambient temperature: Operating ambient humidity: 3 to 8% non-condensing Start-up the pump at the same level as the atmospheric pressure Improvement Suggestion Our compressors and vacuum pumps employ a unique internal coil cooling feature to reduce or control the rise in internal temperature. If they are operated at higher than rated pressures, elevated temperatures may result. Should these temperatures become excessive, operating duty cycles may need to be reduced, or the use of an auxiliary cooling fan should be considered. This catalogue will give the guidelines needed to determine the appropriate model for your application(s). However, in certain cases you may need further detailed information, which will be provided in the form of a specifications sheet for each model/version by our technical staff who will further assist you in your selection. and designs are subject to change at any time without notice. It is recommended that OEM customers confirm the required specifications in writing before placing orders. 4

6 Series Selection AC Linear Free Piston Compressor Rated Pressure Max. Pressure Rated Pressure & Max. Pressure kpa psig kpa psig L/min cfm Rated Page AC AC21A AC31A AC41A AC AC AC AC AC AC AC41A AC61/ AC61A /23 AC AC AC Linear Free Piston Pump Attainable Attainable kpa in.hg L/min cfm Free Air Displacement Free Air Displacement Page VP VP VP43A VP VP VP VP92A VP VP94T VP VP VP66x2 Series Parallel DC Linear Free Piston Compressor Rated Pressure Max. Pressure Rated Pressure & Max. Pressure Rated Page kpa psig kpa psig L/min cfm DAH12-X DAH12-Y DAH-X DAH-Y DAH11-X DAH11-Y DC Linear Free Piston Pump Attainable Attainable kpa in.hg L/min cfm Free Air Displacement Free Air Displacement Page DVH13-X DVH13-Y DVH14-X DVH14-Y

7 AC Linear Free Piston Compressor Rated Pressure Max. Pressure Rated Pressure & Max. Pressure Rated Page kpa psig kpa psig L/min cfm AC AC12 Linear Diaphragm 2 4Pump.69 (Blower Type) AC21A 1 Rated Max. 2Rated.71 1 AC31A Pressure Pressure Rated Pressure & Max. Pressure kpa psig kpa psig L/min cfm Page 11 AC41A VC AC62 VC AC91 VC11E AC92 VC11S AC VC21B AC11 VC31B AC AC41A AC61A AC AC AC Linear Diaphragm Pump (Dual Type) Attainable Attainable Rated Pressure Max. Pressure Rated Pressure & Max. Pressure kpa in.hg kpa psig kpa psig L/min cfm Rated Page VC VC11 12 V VC11 23 V VC11E VC11S VC21B VC31B VCK12 ( only) *.64* 67 *Free Air Displacement DC Liquid Pump DPE-1 Working Pressure Range kpa psig to 1 to 14. Working Pressure Range Flow Rate ml/min 1 Flow Rate Self-priming Pressure kpa psig Self-priming Pressure Page 98 DPE-4 to 1 to DPE-4BL to 1 to DPE-8 to 1 to (ml/min) *Test conditions: Water at 2 degrees C 6

8 DC Linear Compressor and Pump (Dual Type) Attainable Attainable Max. Pressure Max. Pressure kpa in.hg kpa psig L/min cfm Free Air Displacement Free Air Displacement Page DP DP DP DP12S DP12H-X DP11-X DP11-Y DP11-X DP11T-X DP11T-Y DP21T-X DP21T-Y DP-X DP-Y DC Linear Compressor only Attainable Attainable Max. Pressure Max. Pressure kpa in.hg kpa psig L/min cfm Free Air Displacement Free Air Displacement Page DP12H-X DPA-X DPA-Y DP41-X DP41-Y DP41T-Y DC Pump only Attainable Attainable Max. Pressure Max. Pressure kpa in.hg kpa psig L/min cfm Free Air Displacement Free Air Displacement Page DP41-X DP41-Y DP41T-X

9 Conversion Tables Pressure / Flow Rate / Pressure kpa kgf/cm 2 (bar) psig Flow Rate CFM LPM CFM LPM kpa mmhg mbar in.hg Pressure to from kpa kgf/cm 2 bar psig kpa kgf/cm bar psig to from kpa mmhg in.hg mbar kpa mmhg in. Hg mbar Gauge pressure Absolute vacuum 8

10 9

11 AIR COMPRESSOR AC AR Free Piston Compressor Page AC12 AC21A AC31A AC41A AC62 AC91 AC92 AC AC11 AC27 AC41A AC61 AC61A AC91 AC

12 Compressor AR AC12 1V/23V 23V & Power Consumption (W) Characteristics 2.2 Hz Power Consumption Characteristics Hz Hz (kgf/cm 2 ) kpa (.2 kgf/cm 2 ) Rated Pressure.2 bar 2.9 psig L/min.177 cfm 4 kpa (.4 kgf/cm 2 ) Maximum Pressure.4 bar.8 psig Rated Voltage 1 V AC 23 V AC 14 W W Rated Frequency 6 Hz Hz (MTTF) 1, hours 6 mm O.D. hose barb Coil Insulation Class Class B for UL 48 (L) x 62 (W) mm 1-7/64" (L) x 2-7/16" (W).7 kg 1.4 Lbs 2 mm 7-7/8" 1 Dripping Machine Blood Pressure Tester 8 18 ø Hz Power Consumption (kgf/cm 2 ) Female Thread M4 for Grounding 62 ø

13 Compressor AR AC21A 1V 23V & Power Consumption (W) Hz Characteristics 2.2 6Hz Power Consumption Characteristics (kgf/cm 2 ).69 1 kpa (.1 kgf/cm 2 ) Rated Pressure.1 bar 1.4 psig 2 L/min.71 cfm 2 kpa (.2 kgf/cm 2 ) Maximum Pressure.2 bar 2.9 psig Rated Voltage 1 V AC 23 V AC 19 W 23 W Rated Frequency 6 Hz Hz AR 6, hours ISO Rc 1/4 Coil Insulation Class E or its equivalent (JETL) and B for UL 73 (L) x 88 (W) mm 2-7/8" (L) x 3-/32" (W) 1. kg 3.3 Lbs 2 mm 7-7/8" 3 2 6Hz Hz Seat Lifter Bed Sore Prevention Mattress 1 Power Consumption (kgf/cm 2 ) A 2 ø1 14 Rc 1/4 IN Grounding Screw M4 View A 88 ø

14 Compressor AR AC31A 1V/23V 23V & Power Consumption (W) Characteristics 2.2 Hz Hz Power Consumption Characteristics (kgf/cm 2 ) 1 kpa (.1 kgf/cm 2 ) Rated Pressure.1 bar 1.4 psig 28 L/min.99 cfm 3 kpa (.3 kgf/cm 2 ) Maximum Pressure.3 bar 4.3 psig Rated Voltage 1 V AC 23 V AC 2 W 29 W Rated Frequency 6 Hz Hz AR 1, hours ISO Rc 1/4 Coil Insulation Class E or its equivalent (JETL) and B for UL 68 (L) x 84 (W) mm 2-43/64" (L) x 3-/16" (W) 1.9 kg 4.2 Lbs 2 mm 7-7/8" 3 Hz 2 Liquid Mixer Seat Lifter 1 6Hz Power Consumption (kgf/cm 2 ) 118 Grounding Screw M4 Rc 1/ ø ø ø 13

15 Compressor AR AC41A 1V 23V & Power Consumption (W) Characteristics Hz 6Hz Power Consumption Characteristics Hz (kgf/cm 2 ) 1 kpa (.1 kgf/cm 2 ) Rated Pressure.1 bar 1.4 psig 3 L/min 1.24 cfm 3 kpa (.3 kgf/cm 2 ) Maximum Pressure.3 bar.7 psig Rated Voltage 12 V AC 23 V AC 3 W 38 W Rated Frequency 6 Hz Hz AR 1, hours ISO Rc 1/4 Coil Insulation Class E or its equivalent (JETL) and A for UL 68 (L) x 84 (W) mm 2-43/64" (L) x 3-/16" (W) 1.9 kg 4.2 Lbs 2 mm 7-7/8" 2 6Hz Liquid Mixer Air Bearing 1 Power Consumption (kgf/cm 2 ) 118 Grounding Screw M4 Rc 1/ ø ø ø 14

16 Compressor AR AC62 1V 23V & Power Consumption (W) Hz Characteristics Hz 2.2 Power Consumption Characteristics Hz (kgf/cm 2 ) 7.11 kpa (. kgf/cm 2 ) Rated Pressure. bar 2.17 psig 4 L/min 1.41 cfm 3 kpa (.3 kgf/cm 2 ) Maximum Pressure.3 bar.7 psig Rated Voltage 1 V AC 23 V AC 2 W 8 W Rated Frequency 6 Hz Hz AR 1, hours ISO Rc 1/4 Coil Insulation Class E or its equivalent (JETL) and A for UL 68 (L) x 84 (W) mm 2-43/64" (L) x 3-/16" (W) 3 kg 6.6 Lbs 23 mm 9-1/4" 3 mm 13-2/32" 4 Air Blaster for Bandsaw Clean Room Ventilation ø A ø Hz 2 Power Consumption (kgf/cm 2 ) Grounding Screw M4 Rc 1/4 View A ø

17 Compressor AR AC91 12V/23V 23V & Power Consumption (W) Power Consumption Characteristics Hz 6Hz (kgf/cm 2 ) Power Consumption Characteristics Hz 6Hz kpa (.1 kgf/cm 2 ) Rated Pressure.1 bar 1.4 psig 8 L/min 2.83 cfm 4 kpa (.4 kgf/cm 2 ) Maximum Pressure.4 bar.8 psig Rated Voltage 12 V AC 23 V AC 88 W 99 W Rated Frequency 6 Hz Hz AR 1, hours ISO Rc 3/8 Coil Insulation Class E or its equivalent (JETL) and B for UL 12 (L) x 13 (W) mm 4-1/64" (L) x -1/8" (W) 4.9 kg 1.8 Lbs 3 mm 11-13/16" Air Lifter for Bathtub Liquid Dispenser 136 Wing Bolt for Non-UL 7 ø14 ø A (kpa ). (kgf/cm2 ) Grounding Screw M4 Rc 3/8 View A 13 ø

18 Compressor AR AC92 1V 23V & Power Consumption (W) Hz Characteristics Hz Power Consumption Characteristics Hz (kgf/cm 2 ) kpa (.2 kgf/cm 2 ) Rated Pressure.2 bar 2.9 psig L/min 1.94 cfm 4 kpa (.4 kgf/cm 2 ) Maximum Pressure.4 bar 6.2 psig Rated Voltage 1 V AC 23 V AC 7 W 8 W Rated Frequency 6 Hz Hz AR 1, hours ISO Rc 3/8 Coil Insulation Class E or its equivalent (JETL) and B for UL 12 (L) x 13 (W) mm 4-1/64" (L) x -1/8" (W) 4.9 kg 1.8 Lbs 3 mm 11-13/16" 32 mm 12-19/32" 6 6Hz Air Lifter for Bathtub Liquid Dispenser 4 Power Consumption (kgf/cm 2 ) Wing Bolt for Non-UL 4 Grounding Screw M4 Rc 3/8 7 ø14 ø A View A ø

19 Compressor AR AC 1V/23V & Power Consumption [W] Hz Characteristics 6Hz (kgf/cm 2 ) Power Consumption Characteristics Hz Rated Pressure kpa (. kgf/cm 2 ). bar 7.2 psig 2. L/min.88 cfm 8 kpa (.8 kgf/cm 2 ) Maximum Pressure.8 bar 11.6 psig Rated Voltage 1 V AC 23 V AC 14 W W Rated Frequency 6 Hz Hz (MTTF), hours 6 mm O.D. hose barb 6 minutes Coil Insulation Class E or its equivalent (JETL) and B for UL 48 (L) x 62 (W) mm 1-7/64" (L) x 2-7/16" (W).7 kg 1.4 Lbs 2 mm 7-7/8" 1 6Hz Saline Water Splasher Copy Paper Separator Power Consumption 8 18 ø (kgf/cm 2 ) 9 2 Female Thread M4 for Grounding 62 ø

20 Compressor AR AC11 1V 23V & Power Consumption (W) Characteristics Hz 6Hz (kgf/cm 2 ) Power Consumption Characteristics Hz kpa (1. kgf/cm 2 ) Rated Pressure 1. bar 14. psig.8 L/min.28 cfm 12 kpa (1.2 kgf/cm 2 ) Maximum Pressure 1.2 bar 17.4 psig Rated Voltage 1 V AC 23 V AC 12 W W Rated Frequency 6 Hz Hz AR 4, hours (MTTF) 6 mm O.D. hose barb 3 minutes Coil Insulation Class E or its equivalent (JETL) and B for UL 48 (L) x 62 (W) mm 1-7/64" (L) x 2-7/16" (W).7 kg 1.4 Lbs 2 mm 7-7/8" 1 6Hz Automatic Dispenser Power Consumption Female Thread M4 for Grounding (39.) ø (kgf/cm 2 ) ø

21 Compressor AR AC27 1V 23V & Power Consumption (W) Hz 6Hz Characteristics Power Consumption Characteristics (kgf/cm 2 ) Hz Rated Pressure 7 kpa (.7 kgf/cm 2 ).7 bar 1. psig 3. L/min.124 cfm 1 kpa (1. kgf/cm 2 ) Maximum Pressure 1. bar 14. psig Rated Voltage 1 V AC 23 V AC 2 W 2 W Rated Frequency 6 Hz Hz 3, hours 4.7 mm O.D. hose barb Coil Insulation Class E or its equivalent (JETL) and B for UL 7 (L) x 88 (W) mm 2-61/64" (L) x 3-/32" (W) 1.7 kg 3.7 Lbs 2 mm 7-7/8" Air Bearing for Precision Machines Nebulizer 9 12 A 2 ø1 IN 14 ø Hz 1 Power Consumption (kgf/cm 2 ) Grounding Screw M4 View A ø

22 Compressor AR AC41A & Power Consumption 23V (W) Hz Characteristics Power Consumption Characteristics Hz Hz (kgf/cm 2 ) kpa (1. kgf/cm 2 ) Rated Pressure 1. bar 14. psig L/min.177 cfm 13 kpa (1.3 kgf/cm 2 ) Maximum Pressure 1.3 bar 18.8 psig Rated Voltage 1 V AC 23 V AC 39 W 43 W Rated Frequency 6 Hz Hz AR 3, hours ISO Rc 1/4 Coil Insulation Class B or its equivalent (JETL) 68 (L) x 98 (W) mm 2-43/64" (L) x 3-/64" (W) 2.1 kg 4.6 Lbs 22 mm 8-21/32" 17 mm 6-11/16" Industrial Sewing Machine Various Aerosol Sprays Hz Power Consumption (kgf/cm 2 ) Rc 1/4 Grounding Screw M ø

23 Compressor AR AC61 1V 23V & Power Consumption (W) Characteristics Hz Hz Power Consumption Characteristics Hz (kgf/cm 2 ) 3.6 Rated Pressure 1 kpa (1. kgf/cm 2 ) 1. bar 14. psig 8 L/min.283 cfm kpa (1. kgf/cm 2 ) Maximum Pressure 1. bar 21.7 psig Rated Voltage 1 V AC 23 V AC 2 W 6 W Rated Frequency 6 Hz Hz 3, hours ISO Rc 1/4 Coil Insulation Class E or its equivalent (JETL) and B for UL 68 (L) x 84 (W) mm 2-43/64" (L) x 3-/16" (W) 3.2 kg 7.1 Lbs 2 mm 7-7/8" 4 6Hz 3 2 Dispenser Automatic Stamper Power Consumption (kgf/cm 2 ) A ø ø Rc 1/4 IN View A Grounding Screw M ø

24 Compressor AR AC61A 1V 23V & Power Consumption (W) Characteristics Hz Hz Power Consumption Characteristics Hz (kgf/cm 2 ) 3.6 Rated Pressure 1 kpa (1. kgf/cm 2 ) 1. bar 14. psig 8 L/min.283 cfm kpa (1. kgf/cm 2 ) Maximum Pressure 1. bar 21.7 psig Rated Voltage 1 V AC 23 V AC 2 W 6 W Rated Frequency 6 Hz Hz 1, hours ISO Rc 1/4 Coil Insulation Class F or its equivalent (JETL) 68 (L) x 84 (W) mm 2-43/64" (L) x 3-/16" (W) 3.2 kg 7.1 Lbs 2 mm 7-7/8" 4 6Hz 3 2 Dispenser Automatic Stamper Power Consumption (kgf/cm 2 ) A ø ø Rc 1/4 IN View A Grounding Screw M ø

25 Compressor AR AC91 1V/23V 23V & Power Consumption (W) Characteristics Hz 6Hz Power Consumption Characteristics (kgf/cm 2 ) kpa (1. kgf/cm 2 ) Rated Pressure 1. bar 14 psig 16 L/min.7 cfm kpa (1. kgf/cm 2 ) Maximum Pressure 1. bar 21.7 psig Rated Voltage 1 V AC 23 V AC 8 W 9 W Rated Frequency 6 Hz Hz AR 3, hours ISO Rc 1/4 Coil Insulation Class E or its equivalent (JETL) or B for UL 12 (L) x 13 (W) mm 4-1/64" (L) x -1/8" (W) 4.9 kg 1.8 Lbs 3 mm 11-13/16" 32 mm 12-19/32" Sealant gun Leakage Tester Air Cylinder/Chuck Driver 136 Wing Bolt for Non-UL Rc 1/ Hz 6 Hz 4 Power Consumption (kgf/cm 2 ) Grounding Screw M4 7 ø14 ø 62 A View A 13 ø

26 Compressor AR AC92 1V (6Hz) 23V (Hz) & Power Consumption (W) Power Consumption Hz Hz Characteristics (kgf/cm 2 ) Power Consumption Characteristics 6Hz Hz Rated Pressure 2 kpa (2. kgf/cm 2 ) 2. bar 29 psig 8 L/min.283 cfm 3 kpa (3. kgf/cm 2 ) Maximum Pressure 3. bar 43. psig Rated Voltage 1 V AC 23 V AC 81 W 1 W Rated Frequency 6 Hz Hz 3, hours ISO Rc 1/4 3 minutes Coil Insulation Class E or its equivalent (JETL) 12 (L) x 13 (W) mm 4-1/64" (L) x -1/8" (W) kg 11 Lbs Air Cylinder/Chuck Driver 3 mm 11-13/16" mm -29/32" Leakage Tester 136 Wing Bolt for Non-UL Rc 1/ (kgf/cm 2 ) Grounding Screw M4 7 ø14 ø 62 A View A 13 ø

27 VACUUM PUMP Page AC AR Free Piston Pump VP12 VP14 VP43A VP4 VP62 VP66 VP92A VP94 VP94T VP64 VP VP66 x

28 Pump AR VP12 1V/23V 23V & Power Consumption Power Consumption (W) (sec) Characteristics Power Consumption Characteristics Hz 6Hz Hz Hz Exhaust Characteristics 6Hz Attainable Free Air Displacement Dripping Machine kpa (-2 mmhg) -333 mbar in. Hg 7 L/min.247 cfm Rated Voltage 1 V AC 23 V AC 14 W W Rated Frequency 6 Hz Hz 1, hours (MTTF) AR 6 mm O.D. hose barb 6 mm O.D. hose barb Coil Insulation Class Class B for UL 48 (L) x 62 (W) mm 1-7/64" (L) x 2-7/16" (W).7 kg 1.4 Lbs 2 mm 7-7/8" Paper Card Dispenser ø ø6 1 Hz (mmhg) (in.hg) (kpa ) - (mmhg) (in.hg ) with 1 L tank Time (kpa ) - (mmhg) (in.hg ) Female Thread M4 for Grounding 62 7 ø

29 Pump AR VP14 1V 23V & Power Consumption Power Consumption (W) (sec) Characteristics Power Consumption Characteristics Hz Hz 6Hz Exhaust Characteristics Hz Hz Attainable * Free Air Displacement *Operations at higher than -3.kPa need an additional leak valve or relief valve on the inlet piping. Dripping Machine -3.3 kpa (-4 mmhg) -33 mbar -.7 in. Hg 3 L/min.16 cfm Rated Voltage 1 V AC 23 V AC 14 W W Rated Frequency 6 Hz Hz, hours (MTTF) AR 6 mm O.D. hose barb 6 mm O.D. hose barb 6 minutes Coil Insulation Class E or its equivalent (JETL) and B for UL 48 (L) x 62 (W) mm 1-7/64" (L) x 2-7/16" (W).7 kg 1.4 Lbs 2 mm 7-7/8" Paper Card Dispenser ø ø with 1 L tank (mmhg) (in.hg) (mmhg) (in.hg ) Time Hz (mmhg) (in.hg) Female Thread M4 for Grounding 62 7 ø

30 Pump AR VP43A 1V 23V & Power Consumption Power Consumption (W) (sec) Characteristics Power Consumption Characteristics Hz Hz Hz Hz Exhaust Characteristics Attainable Free Air Displacement Machine Screw Feeder kpa (-3 mmhg) -467 mbar in. Hg 2 L/min.88 cfm Rated Voltage 1 V AC 23 V AC 39 W Rated Frequency 6 Hz Hz 3, hours mm O.D. hose barb AR ISO Rc 1/4 Coil Insulation Class B or its equivalent (JETL) and B for UL 68 (L) x 84 (W) mm 2-43/64" (L) x 3-/16" (W) 2.3 kg.1 Lbs 3 mm 11-13/16" Air Sampler mm 21-21/32" Rc 1/4 Rc 1/ with 1 L tank (mmhg) (in.hg ) (mmhg) (in.hg ) 1 Hz Time 6Hz (mmhg) (in.hg ) 122 Grounding Screw M4 84 ø

31 Pump AR VP4 12V 23V & Power Consumption Power Consumption (W) (sec) Characteristics Power Consumption Characteristics Hz Hz 6Hz Hz Exhaust Characteristics Attainable Free Air Displacement kpa (- mmhg) -667 mbar in. Hg 18 L/min.64 cfm Rated Voltage 12 V AC 23 V AC 34 W 3 W Rated Frequency 6 Hz Hz 1, hours ISO Rc 1/4 AR ISO Rc 1/4 Coil Insulation Class E or its equivalent (JETL) and A for UL 8 (L) x 88 (W) mm 3-11/32" (L) x 3-/32" (W) 2.2 kg 4.9 Lbs 3 mm 11-13/16" Machine Screw Feeder Air Sampler (13.7) 68 (148) 144. Grounding Screw M4 (13.) 13 Rc 1/4 Rc 1/ Hz with 1 L tank (mmhg) (in.hg) -8. (kpa ) -6 (mmhg) (in.hg ) 4 Time Hz (mmhg) (in.hg) 4 ø

32 Pump AR VP62 1V/23V 23V & Power Consumption Power Consumption (W) (sec) Characteristics Power Consumption Characteristics Hz Exhaust Characteristics Hz Hz Hz 6Hz with 1 L tank (mmhg) (in.hg) (mmhg) (in.hg) Attainable Free Air Displacement kpa (-2 mmhg) -333 mbar in. Hg 4 L/min 1.41 cfm Rated Voltage 1 V AC 23 V AC 6 W Rated Frequency 6 Hz Hz 1, hours mm O.D. hose barb AR ISO Rc 1/4 Coil Insulation Class E or its equivalent (JETL) and B for UL 68 (L) x 84 (W) mm 2-43/64" (L) x 3-/16" (W) 3 kg 6.6 Lbs 23 mm 9-1/4" 32 mm 12-19/32" Solar Collection Screen 118 Rc 1/8 138 Grounding Screw M Time Hz (mmhg) (in.hg) Rc 1/4 A 6 ø14 ø View A ø

33 Pump AR VP66 1V (6Hz) 23V (Hz) & Power Consumption Power Consumption (W) (sec) Characteristics 6Hz Hz Power Consumption Characteristics Attainable * 1 Free Air Displacement *1: Operations at higher than -3.kPa need an additional leak valve or relief valve on the inlet piping. Material Handling Equipment -8 kpa (-6 mmhg) -8 mbar in. Hg 2 L/min.88 cfm Rated Voltage 1 V AC 23 V AC 7 W 6 W Rated Frequency 6 Hz Hz 6, hours ISO Rc 1/4 AR ISO Rc 1/4 Coil Insulation Class E or its equivalent (JETL) and B for UL 12 (L) x 13 (W) mm 4-1/64" (L) x -1/8" (W) kg 11 Lbs 3 mm 11-13/16" 6 mm 23-/8" Chucking 136 Rc 1/4 Rc 1/4 ø Grounding Screw M Hz Hz Exhaust Characteristics with 1 L tank (mmhg) (in.hg) (mmhg) (in.hg) 4 3 6Hz Time Hz (mmhg) (in.hg)

34 Pump AR VP92A & Power Consumption Power Consumption (W) (sec) Characteristics Power Consumption Characteristics Hz Hz Exhaust Characteristics Hz Hz Hz with 1 L tank 2.83 Attainable * 1 Free Air Displacement *1: Operations at higher than -33.3kPa need an additional leak valve or relief valve on the inlet piping kpa (-2 mmhg) -333 mbar in. Hg 8 L/min 2.83 cfm Rated Voltage 1 V AC 23 V AC 9 W 88 W Rated Frequency 6 Hz Hz 1, hours ISO Rc 1/4 AR ISO Rc 1/4 Coil Insulation Class B or its equivalent (JETL) 12 (L) x 13 (W) mm 4-1/64" (L) x -1/8" (W) 4. kg 9.9 Lbs 3 mm 11-13/16" 32 mm 12-19/32" Material Handling Equipment Rc 1/4 Rc 1/4 8 ø (mmhg) (in.hg) (mmhg) (in.hg) 6Hz Time (kpa ) -6 (mmhg) (in.hg) 4 Grounding Screw M

35 Pump AR VP94 1V/23V 1V/23V & Power Consumption Power Consumption (W) (sec) Characteristics Hz Hz Power Consumption Characteristics Hz Hz Exhaust Characteristics Hz with 1 L tank 2.47 Attainable * 1 Free Air Displacement *1: Operations at higher than -3.3kPa need an additional leak valve or relief valve on the inlet piping kpa (-4 mmhg) -33 mbar -.7 in. Hg 6 L/min 2.12 cfm Rated Voltage 1 V AC 23 V AC 9 W Rated Frequency 6 Hz Hz 1, hours ISO Rc 1/4 AR ISO Rc 1/4 Coil Insulation Class B or its equivalent (JETL) and B for UL 12 (L) x 13 (W) mm 4-1/64" (L) x -1/8" (W) 4. kg 1. Lbs Label Sticking Machine 3 mm 11-13/16" 32 mm 12-19/32" Rc 1/4 Rc 1/4 8 ø (mmhg) (in.hg) (mmhg) (in.hg) 1 6Hz Time (mmhg) (in.hg) 4 Grounding Screw M

36 Pump AR VP94T & Power Consumption Characteristics Power Consumption Characteristics Attainable * 1 Free Air Displacement *1: Operations at higher than -3.3kPa need an additional leak valve or relief valve on the inlet piping. *2: UL Pending -3.3 kpa (-4 mmhg) -33 mbar -.7 in. Hg 12 L/min 4.24 cfm Rated Voltage 1 V AC * 2 23 V AC 18 W Rated Frequency 6 Hz Hz 1, hours ISO Rc 3/8 AR ISO Rc 3/8 Coil Insulation Class B or its equivalent (JETL) 172 (L) x 211 (W) mm 6-49/64" (L) x 8-/16" (W) 1 kg 22 Lbs Wiring diagram White 3 mm 11-13/16" 32 mm 12-19/32" Coil A Coil B Coil A Coil B Silicon Diode Black White Silicon Diode 1 V AC or 23 V AC Black Rc 3/8 (PT 3/8) Female Thread M4 for Grounding 277 Rc 3/8 (PT 3/8) Power Consumption (W) Time (sec) Hz Hz (kpa ) (mmhg) (in.hg) Hz 6Hz (kpa ) (mmhg) (in.hg ) Exhaust Characteristics Hz 6Hz (kpa ) (mmhg) (in.hg ) 6 ø

37 Pump AR VP64 & Power Consumption Power Consumption (W) (sec) Characteristics Power Consumption Characteristics Hz 6Hz Hz Hz Exhaust Characteristics 6Hz with 1 L tank Attainable * 1 Free Air Displacement -6 kpa (-4 mmhg) -6 mbar in. Hg 1 L/min.3 cfm Rated Voltage 1 V AC 23 V AC 48 W W Rated Frequency 6 Hz Hz 3, hours mm O.D. hose barb AR ISO Rc 1/4 Coil Insulation Class E or its equivalent (JETL) 68 (L) x 84 (W) mm 2-43/64" (L) x 3-/16" (W) 3.2 kg 7.1 Lbs 2 mm 7-7/8" A ø ø Rc 1/ (mmhg) (in.hg) (mmhg) (in.hg) *1: Operations at higher than -6kPa need an additional leak valve or relief valve on the inlet piping. 3 2 Hz Time (mmhg) (in.hg) 138 In View A ø Grounding Screw M4 36

38 Pump AR VP94 & Power Consumption Power Consumption (W) (sec) Characteristics 6Hz Power Consumption Characteristics 6Hz Hz Hz Exhaust Characteristics 6Hz with 1 L tank (mmhg) (in.hg) (mmhg) (in.hg) Attainable * 1 Free Air Displacement -6 kpa (-4 mmhg) -6 mbar in. Hg 12 L/min.42 cfm Rated Voltage 1 V AC 23 V AC 7 W 8 W Rated Frequency 6 Hz Hz 3, hours mm O.D. hose barb AR ISO Rc 1/4 Coil Insulation Class E or its equivalent (JETL) 12 (L) x 13 (W) mm 4-1/64" (L) x -1/8" (W) 4.9 kg 1.8 Lbs Vice 3 mm 11-13/16" 32 mm 12-19/32" *1: Operations at higher than -6kPa need an additional leak valve or relief valve on the inlet piping. Impregnation Depressurizer 3 Time 136 Wing Bolt for Non-UL Rc 1/ Hz (mmhg) (in.hg) 4 Grounding Screw M4 7 ø14 ø 62 A View A 13 ø

39 Pump AR VP66x2 & Power Consumption (sec) Characteristics (Series air connection) Characteristics (Parallel air connection) Exhaust Characteristics Attainable * 1 Free Air Displacement Series Connection *1: Operations at higher than -93.3kPa in series or -8kPa in parallel need an additional leak valve or relief valve on the inlet piping kpa (-7 mmhg) -933 mbar in. Hg 2 L/min.88 cfm Parallel Connection -8 kpa (-6 mmhg) -8 mbar in. Hg L/min 1.77 cfm 6, hours Rated Voltage 1 V AC 23 V AC 12 W 1 W Rated Frequency 6 Hz Hz ISO Rc 1/4, 2 ports AR ISO Rc 1/4, 2 ports Coil Insulation Class B or its equivalent (JETL) 28 (L) x 13 (W) mm 11-1/32" (L) x -1/8" (W) 1 kg 22 Lbs mm 6 mm -7/8" 23-/8" Series Connection Silencer OUT IN IN OUT Airfilter Wiring diagram Coil A Coil B Coil A Coil B Silicon Diode Silicon Diode Parallel Connection Silencer OUT IN Airfilter IN OUT * Air line connection is required by the user. 1 V AC or 23 V AC 136 Rc 1/4 Rc 1/ (Series) with 1 L tank (mmhg) (in.hg) (mmhg) (in.hg) Time (Parallel) (mmhg) (in.hg) 4 Grounding Screw M4 13 ø

40 39

41 AIR COMPRESSOR Page DAH12-X1-41 DC Linear Free Piston Compressor DAH12-Y1-42 DAH-X1-43 DAH-Y1-44 DAH11-X1-4 DAH11-Y1-46 4

42 Compressor AR DAH12-X1 12 V DC & Electric Current Characteristics Current Characteristics Rated Pressure Maximum Pressure Rated Voltage Current (Mean Value) Coil Insulation Class 2 kpa (.2 kgf/cm 2 ).2 bar 2.9 psig L/min *1.177 cfm kpa (. kgf/cm 2 ). bar 7.2 psig 12 V DC.81 A 1, hours 6 mm O.D. hose barb A or its equivalent 76 (L) x 7 (W) mm 2-63/64" (L) x 2-3/4" (W).91 kg 2.1 Lbs 3 mm 11-13/16" Optional Accessory (LB7793) Red (+) Black (-) 4 x ø4. 64 Female Thread M4 for Grounding 1 1 ø6 48 (A) (kgf/cm 2 ) Electric Current (Mean Value) (kgf/cm 2 ) Heavy duty rubber feet available on request. Medical equipment, analyzers, etc

43 Compressor AR DAH12-Y1 24 V DC & Electric Current (A) 8 Characteristics Current Characteristics Rated Pressure 2 kpa (.2 kgf/cm 2 ).2 bar 2.9 psig L/min *1.177 cfm kpa (. kgf/cm 2 ) Maximum Pressure. bar 7.2 psig Rated Voltage 24 V DC Current (Mean Value).4 A AR 1, hours 6 mm O.D. hose barb Coil Insulation Class A or its equivalent 76 (L) x 7 (W) mm 2-63/64" (L) x 2-3/4" (W).91 kg 2.1 Lbs 3 mm 11-13/16" Optional Accessory (LB7793) Heavy duty rubber feet available on request. Medical equipment, analyzers, etc Red (+) Black (-) 4 x ø4. 64 Female Thread M4 for Grounding 1 1 ø (kgf/cm 2 ) Electric Current (Mean Value) (kgf/cm 2 )

44 Compressor AR DAH-X1 12 V DC & Electric Current (A) Characteristics Current Characteristics (kgf/cm 2 ) 14.2 Rated Pressure Maximum Pressure Rated Voltage Current (Mean Value) (MTTF) Coil Insulation Class kpa (. kgf/cm 2 ). bar 7.2 psig 2. L/min *1.88 cfm 8 kpa (.8 kgf/cm 2 ).8 bar 11.6 psig 12 V DC.74 A 1, hours 6 mm O.D. hose barb A or its equivalent 76 (L) x 7 (W) mm 2-63/64" (L) x 2-3/4" (W).91 kg 2.1 Lbs 3 mm 11-13/16" Optional Accessory (LB7793) Electric Current (Mean Value) Red (+) Black (-) 4 x ø4. 64 Female Thread M4 for Grounding 1 1 ø (kgf/cm 2 ) 14.2 Heavy duty rubber feet available on request. Medical equipment, analyzers, etc

45 Compressor AR DAH-Y1 24 V DC & Electric Current (A) Characteristics Current Characteristics (kgf/cm 2 ) 14.2 Rated Pressure kpa (. kgf/cm 2 ). bar 7.2 psig 2. L/min *1.88 cfm 8 kpa (.8 kgf/cm 2 ) Maximum Pressure.8 bar 11.6 psig Rated Voltage 24 V DC Current (Mean Value).3 A AR (MTTF) 1, hours 6 mm O.D. hose barb Coil Insulation Class A or its equivalent 76 (L) x 7 (W) mm 2-63/64" (L) x 2-3/4" (W).91 kg 2.1 Lbs 3 mm 11-13/16".4.3 Optional Accessory (LB7793) Electric Current (Mean Value) Red (+) Black (-) 4 x ø4. 64 Female Thread M4 for Grounding 1 1 ø (kgf/cm 2 ) 14.2 Heavy duty rubber feet available on request. Medical equipment, analyzers, etc

46 Compressor AR DAH11-X1 12 V DC & Electric Current (A) Characteristics Current Characteristics Rated Pressure Maximum Pressure Rated Voltage Current (Mean Value) (MTTF) Coil Insulation Class 1 kpa (1. kgf/cm 2 ) 1. bar 14. psig 1. L/min *1.3 cfm 12 kpa (1.2 kgf/cm 2 ) 1.2 bar 17.4 psig 12 V DC.74 A, hours 4.7 mm O.D. hose barb A or its equivalent 76 (L) x 7 (W) mm 2-63/64" (L) x 2-3/4" (W).91 kg 2.1 Lbs 3 mm 11-13/16" Optional Accessory (LB7793) 76 7 Red (+) Black (-) 4 x ø Female Thread M4 for Grounding 48 ø (kgf/cm 2 ) Electric Current (Mean Value) (kgf/cm 2 ) Heavy duty rubber feet available on request. Medical equipment, analyzers, etc. 4 82

47 Compressor AR DAH11-Y1 24 V DC & Electric Current Characteristics Current Characteristics Rated Pressure 1 kpa (1. kgf/cm 2 ) 1. bar 14. psig 1. L/min *1.3 cfm 12 kpa (1.2 kgf/cm 2 ) Maximum Pressure 1.2 bar 17.4 psig Rated Voltage 24 V DC Current (Mean Value).27 A AR (MTTF), hours 4.7 mm O.D. hose barb Coil Insulation Class A or its equivalent 76 (L) x 7 (W) mm 2-63/64" (L) x 2-3/4" (W).91 kg 2.1 Lbs 3 mm 11-13/16" Optional Accessory (LB7793) 76 7 Red (+) Black (-) 4 x ø Female Thread M4 for Grounding 48 ø (A) (kgf/cm 2 ) Electric Current (Mean Value) (kgf/cm 2 ) Heavy duty rubber feet available on request. Medical equipment, analyzers, etc

48 47

49 VACUUM PUMP Page DVH13-X1-49 DC Linear Free Piston Pump DVH13-Y1- DVH14-X1-1 DVH14-Y1-2 48

50 Pump AR DVH13-X1 12 V DC & Electric Current Characteristics Current Characteristics Attainable Free Air Displacement Rated Voltage Current (Mean Value) Coil Insulation Class *1: Free air displacement at no-load operation. -4 kpa (-3 mmhg) -4 mbar in. Hg 7 L/min *1.247 cfm 12 V DC.86 A 1, hours 6 mm O.D. hose barb 6 mm O.D. hose barb A or its equivalent 76 (L) x 7 (W) mm 2-63/64" (L) x 2-3/4" (W).91 kg 2.1 Lbs 3 mm 11-13/16" Optional Accessory (LB7793) Heavy duty rubber feet available on request. Medical equipment, analyzers, etc Red (+) Black (-) 4 x ø4. 64 Female Thread M4 for Grounding ø (mmhg) (in.hg) (A) Electric Current (Mean Value) (mmhg) (in.hg)

51 Pump AR DVH13-Y1 24 V DC & Electric Current Characteristics Current Characteristics Attainable Free Air Displacement Rated Voltage Current (Mean Value) AR Coil Insulation Class *1: Free air displacement at no-load operation. -4 kpa (-3 mmhg) -4 mbar in. Hg 7 L/min *1.247 cfm 24 V DC.41 A 1, hours 6 mm O.D. hose barb 6 mm O.D. hose barb A or its equivalent 76 (L) x 7 (W) mm 2-63/64" (L) x 2-3/4" (W).91 kg 2.1 Lbs 3 mm 11-13/16" Optional Accessory (LB7793) Heavy duty rubber feet available on request. Medical equipment, analyzers, etc Red (+) Black (-) 4 x ø4. 64 Female Thread M4 for Grounding ø (mmhg) (in.hg) (A).6..4 Electric Current (Mean Value) (mmhg) (in.hg) 48 82

52 Pump AR DVH14-X1 12 V DC & Electric Current Characteristics Current Characteristics Attainable Free Air Displacement Rated Voltage Current (Mean Value) (MTTF) Coil Insulation Class -6 kpa (-4 mmhg) -6 mbar in. Hg 3 L/min *1.16 cfm 12 V DC.73 A 1, hours 6 mm O.D. hose barb 6 mm O.D. hose barb A or its equivalent 76 (L) x 7 (W) mm 2-63/64" (L) x 2-3/4" (W).91 kg 2.1 Lbs 3 mm 11-13/16" *1: Free air displacement at no-load operation. Optional Accessory (LB7793) Red (+) Black (-) 4 x ø4. 64 Female Thread M4 for Grounding ø6 (mmhg) (in.hg) (A) Electric Current (Mean Value) (mmhg) (in.hg) Heavy duty rubber feet available on request. 48 Medical equipment, analyzers, etc. 1 82

53 Pump AR DVH14-Y1 24 V DC & Electric Current (A) Characteristics Current Characteristics Attainable Free Air Displacement Rated Voltage Current (Mean Value) (MTTF) AR Coil Insulation Class -6 kpa (-4 mmhg) -6 mbar in. Hg 3 L/min *1.16 cfm 24 V DC.34 A 1, hours 6 mm O.D. hose barb 6 mm O.D. hose barb A or its equivalent 76 (L) x 7 (W) mm 2-63/64" (L) x 2-3/4" (W).91 kg 2.1 Lbs 3 mm 11-13/16" *1: Free air displacement at no-load operation. Optional Accessory (LB7793) Red (+) Black (-) 4 x ø4. 64 Female Thread M4 for Grounding ø (mmhg) (in.hg).6..4 Electric Current (Mean Value) (mmhg) (in.hg) Heavy duty rubber feet available on request. 48 Medical equipment, analyzers, etc. 82 2

54 3

55 DIAPHRAGM PUMP Page AC Linear Diaphragm Pump VC1 Dual Type VC1 Blower Type VC11 DualType VC11 Blower Type VC11E DualType VC11E Blower Type VC11S DualType VC11S Blower Type- 62 VC21B DualType - 63 VC21B Blower Type- 64 VC31B DualType - 6 VC31B Blower Type- 66 VCK12 Type- 67 4

56 Compressor and Pump DIAPHRAGM VC1 Dual Type 1V 23V & Power Consumption Characteristics Power Consumption Characteristics 4 kpa (.4 kgf/cm 2 ) Rated Pressure.4 bar.8 psig 6 L/min.212 cfm 16 kpa (.16 kgf/cm 2 ) Maximum Pressure.16 bar 2.32 psig kpa (-11 mmhg) Attainable -147 mbar in.hg Rated Voltage AR 12 V AC 23 V AC 6 W Rated Frequency 6 Hz Hz, hours Working Pressure Range Massage Devices kpa to 16 kpa (-11 mmhg to.16 kgf/cm 2 ) -147 mbar to.16 bar in.hg to 2.28 psig 6 mm O.D. hose barb 6 mm O.D. hose barb Coil Insulation Class A for 12V or its equivalent E for 23V or its equivalent 7 (L) x 72 (W) mm 2-3/4" (L) x 2-3/64" (W).4 kg.99 Lbs 3 mm 11-13/16" Bedsore Prevention Mattress x ø ø6 (68) (W) Power Consumption 3 17 ø6 7 (82) (mmhg) (kgf/cm 2 ) (in.hg) Hz 6Hz 6Hz Hz (mmhg) (kgf/cm 2 ) (in.hg)

57 Compressor DIAPHRAGM VC1 Blower Type 12V 23V & Power Consumption (W) Hz Characteristics Hz Power Consumption Characteristics 6Hz 4 kpa (.4 kgf/cm 2 ) Rated Pressure.4 bar.8 psig 6 L/min.212 cfm 16 kpa (.16 kgf/cm 2 ) Maximum Pressure.16 bar 2.32 psig Rated Voltage 12 V AC 23 V AC 6 W Rated Frequency 6 Hz Hz AR 1, hours Working Pressure Range to 16 kpa ( to.16 kgf/cm 2 ) to.16 bar to 2.28 psig 6 mm O.D. hose barb Coil Insulation Class A for 12V or its equivalent E for 23V or its equivalent 7 (L) x 72 (W) mm 2-3/4" (L) x 2-3/64" (W).4 kg.99 Lbs 3 mm 11-13/16" Massage Devices Bedsore Prevention Mattress 7 (82) 4 x ø ø6 (68) (kgf/cm 2 ) Hz Power Consumption (kgf/cm 2 )

58 Compressor and Pump DIAPHRAGM VC11 Dual Type 1V 23V & Power Consumption (W) Power Consumption (mmhg) (in.hg) Characteristics Power Consumption Characteristics 1 kpa (.1 kgf/cm 2 ) Rated Pressure.1 bar 1.4 psig 1 L/min.3 cfm Rated Voltage 12 V AC 23 V AC Maximum Pressure AR Attainable Working Pressure Range Massage Devices 18 kpa (.18 kgf/cm 2 ).18 bar 2.61 psig kpa (-14 mmhg) -187 mbar -.1 in.hg kpa to 18 kpa (-14 mmhg to.18 kgf/cm 2 ) -187 mbar to.18 bar -.1 in.hg to 2.61 psig kpa (. kgf/cm 2 ). bar 2.17 psig -1 kpa (-76 mmhg) -1 mbar -2.9 in.hg -1 kpa to kpa (-76 mmhg to. kgf/cm 2 ) -1 mbar to. bar -2.9 in.hg to 2.17 psig 11 W Rated Frequency 6 Hz Hz, hours 7. mm O.D. hose barb 7. mm O.D. hose barb Coil Insulation Class B for 12V or its equivalent B for 23V or its equivalent 66 (L) x 1 (W) mm 2-19/32" (L) x 2-/16" (W).82 kg 1.81 Lbs 3 mm 7-7/8" Bedsore Prevention Mattress x ø7. (6) (93) 4 x ø4. (38) (9) (66) 1 (114) ø7. L (11) (mmhg) (in.hg) Hz 6Hz (kgf/cm 2 ) Hz Hz (kgf/cm 2 )

59 Compressor DIAPHRAGM VC11 Blower Type 12V 23V & Power Consumption (W) Characteristics Hz..71 Power Consumption Characteristics 6Hz Hz kpa (.1 kgf/cm 2 ) Rated Pressure.1 bar 1.4 psig 1 L/min.3 cfm 2 kpa (.2 kgf/cm 2 ) Maximum Pressure.2 bar 2.9 psig Rated Voltage 12 V AC 23 V AC 11 W Rated Frequency 6 Hz Hz AR 1, hours Working Pressure Range to 2 kpa ( to.2 kgf/cm 2 ) to.2 bar to 2.9 psig 7. mm O.D. hose barb Coil Insulation Class A for 12V or its equivalent E for 23V or its equivalent 66 (L) x 1 (W) mm 2-19/32" (L) x 3-/16" (W).82 kg 1.81 Lbs 2 mm 7-7/8" Massage Devices Bedsore Prevention Mattress 66 (6) (93) 4 x ø4. (38) (9) (66) 1 (114) ø7. L (11) 2.2 (kgf/cm 2 ) 3.6 Power Consumption 1 Hz (kgf/cm 2 )

60 Compressor and Pump DIAPHRAGM VC11E Dual Type 1V 23V & Power Consumption (W) Power Consumption (mmhg) -2 (in.hg) 2 1 (mmhg) (in.hg) Characteristics Power Consumption Characteristics Hz 1 kpa (.1 kgf/cm 2 ) Rated Pressure.1 bar 1.4 psig L/min.3 cfm 2 kpa (.2 kgf/cm 2 ) Maximum Pressure.2 bar 2.9 psig kpa (-14 mmhg) Attainable -186 mbar -.1 in.hg Rated Voltage AR 12 V AC 23 V AC 11. W Rated Frequency 6 Hz Hz, hours Working Pressure Range Coil Insulation Class A UL approved model for 12V is available upon request. Massage Devices kpa to 2 kpa (-14 mmhg to.2 kgf/cm 2 ) -187 mbar to.2 bar -.1 in.hg to 2.9 psig 7. mm O.D. hose barb 7. mm O.D. hose barb E or its equivalent (JETL) 66 (L) x 1 (W) mm 2-19/32" (L) x 3-/16" (W).82 kg 1.81 Lbs 3 mm 11-13/16" Bedsore Prevention Mattress x ø7. (6) (93) 4 x ø4. (38) (9) (66) 1 (114) ø7. L (11) Hz 6Hz Hz (kgf/cm 2 ) (kgf/cm 2 )

61 Compressor DIAPHRAGM VC11E Blower Type 12V 23V & Power Consumption (W) Hz Characteristics Hz Power Consumption Characteristics 6Hz (kgf/cm 2 ) kpa (.1 kgf/cm 2 ) Rated Pressure.1 bar 1.4 psig L/min.3 cfm 2 kpa (.2 kgf/cm 2 ) Maximum Pressure.2 bar 2.9 psig Rated Voltage 12 V AC 23 V AC 11. W Rated Frequency 6 Hz Hz AR, hours Working Pressure Range Coil Insulation Class A UL approved model for 12V is available upon request. to 2 kpa ( to.2 kgf/cm 2 ) to.2 bar to 2.9 psig 7. mm O.D. hose barb E or its equivalent (JETL) 66 (L) x 1 (W) mm 2-19/32" (L) x 3-/16" (W).82 kg 1.81 Lbs 3 mm 11-13/16" Power Consumption Massage Devices Bedsore Prevention Mattress 66 (6) (93) 4 x ø4. (38) (9) (66) 1 (114) ø7. L (11) Hz (kgf/cm 2 )

62 Compressor and Pump DIAPHRAGM VC11S Dual Type 1V 23V & Power Consumption (W) Power Consumption (mmhg) -2 (in.hg) (mmhg) -2 (in.hg) Characteristics Power Consumption Characteristics Hz kpa (. kgf/cm 2 ) Rated Pressure. bar.72 psig L/min.3 cfm 26 kpa (.26 kgf/cm 2 ) Maximum Pressure.26 bar 3.77 psig -24 kpa (-18 mmhg) Attainable -24 mbar -7.9 in.hg Rated Voltage AR 12 V AC * 1 23 V AC W Rated Frequency 6 Hz Hz, hours Working Pressure Range Coil Insulation Class Massage Devices -24 kpa to 26 kpa (-18 mmhg to.26 kgf/cm 2 ) -24 mbar to.26 bar -7.9 in.hg to 3.77 psig 7. mm O.D. hose barb 7. mm O.D. hose barb 6 minutes B or its equivalent (JETL) 66 (L) x 1 (W) mm 2-19/32" (L) x 3-/16" (W).82 kg 1.81 Lbs 3 mm 11-13/16" Bedsore Prevention Mattress x ø7. (6) (93) 4 x ø4. (38) (9) (66) 1 (114) ø7. L (11) Hz Hz Hz (kgf/cm 2 ) (kgf/cm 2 ) 4.26 *1: 12V AC UL version is unavailable

63 Compressor DIAPHRAGM VC11S Blower Type 12V 23V & Power Consumption (W) Hz Characteristics Hz Power Consumption Characteristics Hz (kgf/cm 2 ) kpa (. kgf/cm 2 ) Rated Pressure. bar.72 psig L/min.3 cfm 26 kpa (.26 kgf/cm 2 ) Maximum Pressure.26 bar 3.77 psig Rated Voltage 12 V AC * 1 23 V AC 14 W Rated Frequency 6 Hz Hz AR, hours Working Pressure Range Coil Insulation Class *1: Non-UL product. to 26 kpa ( to.26 kgf/cm 2 ) to.26 bar to 3.77 psig 7. mm O.D. hose barb 6 minutes B or its equivalent (JETL) 66 (L) x 1 (W) mm 2-19/32" (L) x 3-/16" (W).83 kg 1.81 Lbs 3 mm 11-13/16" Massage Devices Bedsore Prevention Mattress 66 (6) (93) 4 x ø4. (38) (9) (66) 1 (114) ø7. L (11) Power Consumption Hz (kgf/cm 2 )

64 Compressor and Pump DIAPHRAGM VC21B Dual Type 12V 23V & Power Consumption Power Consumption (mmhg) -2 (in.hg) (W) (mmhg) (in.hg) Characteristics Power Consumption Characteristics kpa (.1 kgf/cm 2 ) Rated Pressure.1 bar 1.4 psig 2 L/min.71 cfm 18 kpa (.18 kgf/cm 2 ) Maximum Pressure.18 bar 2.61 psig kpa (-14 mmhg) Attainable -187 mbar -.1 in.hg Rated Voltage AR 12 V AC 23 V AC 21 W Rated Frequency 6 Hz Hz 1, hours Working Pressure Range Coil Insulation Class kpa to 18 kpa (-14 mmhg to.18 kgf/cm 2 ) -187 mbar to.18 bar -.1 in.hg to 2.61 psig 1. mm O.D. hose barb 8. mm O.D. hose barb E or its equivalanet (JETL) and A for UL 12 (L) x 6 (W) mm 4-9/64" (L) x 2-13/64" (W) 1.7 kg 3.7 Lbs 3 mm 11-13/16" Solder Fume Suction ø1.4 ø9. 6 (13.1) 4 x ø ø8. ø Grounding Screw M4 (3) (9.3) (6) (7) Hz 6Hz..71 Hz (kgf/cm 2 ) Hz 2.2 (kgf/cm 2 ) 3.6 Bedsore Prevention Mattress

65 Compressor DIAPHRAGM VC21B Blower Type & Power Consumption 23V (W) Hz Characteristics Hz Power Consumption Characteristics Hz kpa (.1 kgf/cm 2 ) Rated Pressure.1 bar 1.4 psig 2 L/min.71 cfm 18 kpa (.18 kgf/cm 2 ) Maximum Pressure.18 bar 2.61 psig Rated Voltage 12 V AC 23 V AC 21 W Rated Frequency 6 Hz Hz 1, hours Working Pressure Range Coil Insulation Class to 18 kpa ( to.18 kgf/cm 2 ) to.18 bar to 2.61 psig 8. mm O.D. hose barb E or its equivalanet (JETL) and A for UL 12 (L) x 6 (W) mm 4-9/64" (L) x 2-13/64" (W) 1.7 kg 3.7 Lbs 3 mm 11-13/16" (13.1) 4 x ø ø8. ø Grounding Screw M4 (3) (9.3) (6) (7) (kgf/cm 2 ) Hz Power Consumption (kgf/cm 2 ) 4.26 Bedsore Prevention Mattress

66 Compressor and Pump DIAPHRAGM VC31B Dual Type 12V 23V & Power Consumption (W) Power Consumption (mmhg) (in.hg) (mmhg) (in.hg) Characteristics Power Consumption Characteristics Hz Hz kpa (.1 kgf/cm 2 ) Rated Pressure.1 bar 1.4 psig 2 L/min.88 cfm 2 kpa (.2 kgf/cm 2 ) Maximum Pressure.2 bar 2.9 psig kpa (-16 mmhg) Attainable -213 mbar -6.3 in.hg Rated Voltage AR 12 V AC 23 V AC 27 W Rated Frequency 6 Hz Hz 1, hours Working Pressure Range Coil Insulation Class kpa to 2 kpa (-16 mmhg to.2 kgf/cm 2 ) -213 mbar to.2 bar -6.3 in.hg to 2.9 psig 1. mm O.D. hose barb 8. mm O.D. hose barb B or its equivalent 12 (L) x 6 (W) mm 4-9/64" (L) x 2-13/64" (W) 1.7 kg 3.7 Lbs 3 mm 11-13/16" Solder Fume Suction ø1.4 ø9. 6 (13.1) 4 x ø ø8. ø Grounding Screw M4 (3) (9.3) (6) (7) 74.3 Hz Hz (kgf/cm 2 ) (kgf/cm 2 ) 4.26 Bedsore Prevention Mattress

67 Compressor DIAPHRAGM VC31B Blower Type & Power Consumption 23V (W) Hz Characteristics Power Consumption Characteristics 6Hz Hz Hz kpa (.1 kgf/cm 2 ) Rated Pressure.1 bar 1.4 psig 2 L/min.88 cfm 2 kpa (.2 kgf/cm 2 ) Maximum Pressure.2 bar 2.9 psig Rated Voltage 12 V AC 23 V AC 27 W Rated Frequency 6 Hz Hz 1, hours Working Pressure Range Coil Insulation Class to 2 kpa ( to.2 kgf/cm 2 ) to.2 bar to 2.9 psig 8. mm O.D. hose barb B or its equivalent 12 (L) x 6 (W) mm 4-9/64" (L) x 2-13/64" (W) 1.7 kg 3.7 Lbs 3 mm 11-13/16" (13.1) 4 x ø ø8. ø Grounding Screw M4 (3) (9.3) (6) (7) (kgf/cm 2 ) 4.26 Power Consumption (kgf/cm 2 ) 4.26 Bedsore Prevention Mattress

68 Pump DIAPHRAGM VCK12 & Power Consumption Power Consumption (W) (sec) Characteristics Power Consumption Characteristics Attainable Free Air Displacement kpa (-2 mmhg) mbar in.hg 18 L/min.64 cfm Rated Voltage 12 V AC 23 V AC 14 W 11 W Rated Frequency 6 Hz Hz, hours ISO Rc 1/8 AR ISO Rc 1/8 Coil Insulation Class B or its equivalent 2 (L) x 128 (W) mm -63/64" (L) x -3/64" (W) 1.9 kg 4.2 Lbs 3 mm 11-13/16" Grounding Screw M View A Hz.3 Hz (mmhg) (in.hg) Exhaust Characteristics (mmhg) (in.hg) 6 4 Hz 6Hz Hz with 1 L tank.71.3 Medical Cup Suction 3 Time 2 6Hz (mmhg) (in.hg) 1 2 Rc 1/8 ø 76 A 67

69 68 DIAPHRAGM PUMP PISTON PUMP DC Motor Driven Diaphragm Pump Piston Pump Page DP12 DP14 DP12 DP12S DP12H-X1 DP12H-X2 DP-X1 DP-Y1 DPA-X1 DPA-Y1 DP11-X1 DP11-Y1 DP11-X3 DP11T-X1 DP11T-Y1 DP21T-X1 DP21T-Y1 DP41-X1 DP41-Y1 DP41-X2 DP41-Y2 DP41T-Y1 DP41T-Y

70 Compressor and Pump DIAPHRAGM DP12 Brush DC Motor 12 V DC & Power Consumption (A) Characteristics (mmhg) (in.hg) Current Characteristics (kgf/cm 2 ) Attainable Free Air Displacement Rated Voltage Maximum Pressure Maximum Current Coil Insulation Class kpa (-2 mmhg) -333 mbar in.hg 2. L/min.88 cfm 12 V DC 3 kpa (.3 kgf/cm 2 ).3 bar 4.3 psig. A 2 hours 3 mm O.D. straight barb 3 mm O.D. straight barb E or its equivalent (JETL) 32 (L) x 32. (W) mm 1-17/64" (L) x 1-9/32" (W).8 kg.18 Lbs.4 Sucking Pen Blood Pressure Tester.2 Electric Current (mmhg) (in.hg) (kgf/cm 2 ) DC Power Input Terminal (+) DC Power Input Terminal (-) 41. Range of Motion (ø18) (4) (41) 32 3 ø27. ø Insulated Rubber Feet ø3.3 ø

71 Compressor and Pump DIAPHRAGM DP14 Brush DC Motor 12 V DC & Power Consumption (A) Characteristics (mmhg) (in.hg) Current Characteristics (kgf/cm 2 ) 7.11 Attainable Free Air Displacement Rated Voltage Maximum Pressure Maximum Current AR Coil Insulation Class -3.3 kpa (-4 mmhg) -33 mbar -.7 in.hg 4. L/min.141 cfm 12 V DC kpa (. kgf/cm 2 ). bar 7.2 psig. A hours mm O.D. straight barb mm O.D. straight barb E or its equivalent (JETL) 2 (L) x 36 (W) mm 2-3/64" (L) x 1-27/64" (W).19 kg.42 Lbs.4.3 Sucking Pen Blood Pressure Tester.2 Electric Current (mmhg) (in.hg) (kgf/cm 2 ) DC Power Input Terminal (ø31) ø ø ø ø6.3 9 Insulated Rubber Feet 2 7

72 Compressor and Pump DIAPHRAGM DP12 Brushless DC Motor 12 V DC & Power Consumption (A) (mmhg) (in.hg) Characteristics Current Characteristics (kgf/cm 2 ) Attainable Free Air Displacement Rated Voltage Maximum Pressure Maximum Current Working Pressure Range Coil Insulation Class kpa (-2 mmhg) -267 mbar in.hg. L/min.177 cfm 12 V DC 4 kpa (.4 kgf/cm 2 ).4 bar 6.2 psig.7 A kpa to 4 kpa (-2 mmhg to.4 kgf/cm 2 ) -267 mbar to.4 bar in.hg to 6.2 psig, hours 6 mm O.D. straight barb 6 mm O.D. straight barb E or its equivalent (JETL) (L) x 3 (W) mm 1-31/32" (L) x 1-3/16" (W).2 kg. Lbs 4 mm -3/4".2 Electric Current (mmhg) (in.hg) (kgf/cm 2 ) Endoscopes Removal of micromachining chips ø (8.) (.) x ø3. 2 View A 64. (68) (31) ø6.3 Insulated Rubber Feet Red (+) Black (-) A 71

73 Compressor and Pump DIAPHRAGM DP12S Brushless DC Motor 24 V DC & Power Consumption (mmhg) (in.hg) (A) Characteristics Current Characteristics (kgf/cm 2 ) Attainable Free Air Displacement Rated Voltage Maximum Pressure Maximum Current AR Working Pressure Range Coil Insulation Class kpa (-2 mmhg) -267 mbar in.hg 7. L/min.247 cfm 24 V DC 4 kpa (.4 kgf/cm 2 ).4 bar 6.2 psig. A kpa to 4 kpa (-2 mmhg to.4 kgf/cm 2 ) -267 mbar to.4 bar in.hg to 6.2 psig, hours 6 mm O.D. straight barb 6 mm O.D. straight barb E or its equivalent (JETL) (L) x 3 (W) mm 1-31/32" (L) x 1-3/16" (W).2 kg. Lbs 4 mm -3/4".2 Electric Current (mmhg) (in.hg) (kgf/cm 2 ) Endoscopes Removal of micromachining chips ø6 9 (8.) (.) x ø3. 2 View A 64. (68) (31) ø6.3 Insulated Rubber Feet Red (+) Black (-) A 72

74 Compressor and Pump DIAPHRAGM DP12H-X1 Brushless DC Motor 12 V DC & Power Consumption (A) (mmhg) (in.hg) Characteristics Current Characteristics (kgf/cm 2 ) Attainable Free Air Displacement Rated Voltage Maximum Pressure Maximum Current Working Pressure Range Coil Insulation Class -.7 kpa (-38 mmhg) -7 mbar - in.hg 4. L/min.141 cfm 12 V DC 8 kpa (.8 kgf/cm 2 ).8 bar 11.6 psig.7 A -.7 kpa to 8 kpa (-38 mmhg to.8 kgf/cm 2 ) -7 mbar to.8 bar - in.hg to 11.6 psig 3, hours 6 mm O.D. straight barb 6 mm O.D. straight barb E or its equivalent (JETL) (L) x 3 (W) mm 1-31/32" (L) x 1-3/16" (W).2 kg. Lbs 4 mm -3/4".2 Electric Current (mmhg) (in.hg) (kgf/cm 2 ) pick up and place devices for CD & DVD Removal of micromachining chips (.) 3 38 ø6 2 x ø3. 2 (68) (81) (68) (31) Insulated rubber Feet ø6.3 Red (+) Black (-) A View A 73

75 Compressor DIAPHRAGM DP12H-X2 Brushless DC Motor 12 V DC & Power Consumption (A).6 Characteristics Current Characteristics (kgf/cm 2 ) Free Air Displacement Rated Voltage Maximum Pressure Maximum Current Working Pressure Range AR Coil Insulation Class 4. L/min.141 cfm 12 V DC 8 kpa (.8 kgf/cm 2 ).8 bar 11.6 psig.7 A to 8 kpa ( to.8 kgf/cm 2 ) to.8 bar to 11.6 psig 3, hours 6 mm O.D. straight barb 6 mm O.D. straight barb E or its equivalent (JETL) (L) x 3 (W) mm 1-31/32" (L) x 1-3/16" (W).2 kg. Lbs 4 mm -3/4".4.2 Electric Current Removal of micromachining chips (kgf/cm 2 ) (.) 3 38 ø6 (68) (81) 67 2 x ø (68) (31) Insulated Rubber Feet ø6.3 Red (+) Black (-) A View A 74

76 Compressor and Pump PISTON DP-X1 Brush DC Motor 12 V DC & Power Consumption (A) (mmhg) (in.hg) Characteristics Current Characteristics (kgf/cm 2 ) Attainable Free Air Displacement Rated Voltage Maximum Pressure Maximum Current Working Pressure Range Coil Insulation Class kpa (- mmhg) -667 mbar in.hg 2.8 L/min.99 cfm 12 V DC 2 kpa (2. kgf/cm 2 ) 2. bar 36.2 psig 1.9 A 3 minutes to 1 kpa (- mmhg to 1 kgf/cm 2 ) -667 mbar to 1 bar in.hg to 14. psig 1, hours mm O.D. straight barb mm O.D. straight barb E or its equivalent (JETL) 42 (L) x 24. (W) mm 1-21/32" (L) x 1-31/32" (W).36 kg.79 Lbs 36 mm 14-11/64".8 Electric Current Vending Machines (mmhg) (in.hg) (kgf/cm 2 ) 94 Red (+) 1 ø 62. Black (-) View A A () 2 43 Insulated Rubber Feet (24.) (3) (41) (42) ø6.3 7

77 Compressor and Pump PISTON DP-Y1 Brush DC Motor 24 V DC & Power Consumption (mmhg) (in.hg) (A) Characteristics Current Characteristics (kgf/cm 2 ) Attainable Free Air Displacement Rated Voltage Maximum Pressure Maximum Current AR Working Pressure Range Coil Insulation Class kpa (- mmhg) -667 mbar in.hg 2.8 L/min.99 cfm 24 V DC 2 kpa (2. kgf/cm 2 ) 2. bar 36.2 psig.9 A 3 minutes to 1 kpa (- mmhg to 1 kgf/cm 2 ) -667 mbar to 1 bar in.hg to 14. psig 1, hours mm O.D. straight barb mm O.D. straight barb E or its equivalent (JETL) 42 (L) x 24. (W) mm 1-21/32" (L) x 1-31/32" (W).36 kg.79 Lbs 36 mm 14-11/64".4 Electric Current (mmhg) (in.hg) (kgf/cm 2 ) Vending Machines 94 Red (+) 1 ø 62. Black (-) View A A () 2 43 Insulated Rubber Feet (24.) (3) (41) (42) ø6.3 76

78 Compressor PISTON DPA-X1 Brushless DC Motor 12 V DC & Power Consumption (A) Characteristics Current Characteristics (kgf/cm 2 ) 42.7 Free Air Displacement Rated Voltage Maximum Pressure Maximum Current Working Pressure Range (MTTF) Coil Insulation Class 2.8 L/min.99 cfm 12 V DC 22 kpa (2.2 kgf/cm 2 ) 2.2 bar 31.9 psig 1.4 A to 1 kpa ( to 1 kgf/cm 2 ) to 1 bar to 14. psig, hours mm O.D. straight barb mm O.D. straight barb A or its equivalent (JETL) 32 (L) x 27. (W) mm 1-9/32" (L) x 1-/64" (W).3 kg.66 Lbs 36 mm 14-11/64" Electric Current (kgf/cm 2 ) 42.7 Vending Machines 68 Red (+) (1) ø A 43 4 View A Insulated Rubber Feet B Black (-) Enlarged B (2:1) (62) Insulated Rubber Feet (1 ) 77

79 Compressor PISTON DPA-Y1 Brushless DC Motor 24 V DC & Power Consumption (A) Characteristics Current Characteristics (kgf/cm 2 ) 42.7 Free Air Displacement Rated Voltage Maximum Pressure Maximum Current Working Pressure Range AR (MTTF) Coil Insulation Class 2.8 L/min.99 cfm 24 V DC 22 kpa (2.2 kgf/cm 2 ) 2.2 bar 31.9 psig.7 A to 1 kpa ( to 1 kgf/cm 2 ) to 1 bar to 14. psig, hours mm O.D. straight barb mm O.D. straight barb A or its equivalent (JETL) 32 (L) x 27. (W) mm 1-9/32" (L) x 1-/64" (W).3 kg.66 Lbs 36 mm 14-11/64" Electric Current (kgf/cm 2 ) 42.7 Vending Machines 68 Red (+) (1) ø A 43 4 View A Insulated Rubber Feet B Black (-) Enlarged B (2:1) (62) Insulated Rubber Feet (1 ) 78

80 Compressor and Pump DIAPHRAGM DP11-X1 Brushless DC Motor 12 V DC & Power Consumption (A) Characteristics (mmhg) (kgf/cm 2 ) (in.hg) Current Characteristics Attainable Free Air Displacement Rated Voltage Maximum Pressure Maximum Current (MTTF) Coil Insulation Class kpa (- mmhg) -667 mbar in.hg 7. L/min.26 cfm 12 V DC kpa (1. kgf/cm 2 ) 1. bar 21.7 psig 1.2 A or less, hours 6 mm O.D. straight barb 6 mm O.D. straight barb A or its equivalent (JETL) (L) x 3 (W) mm 1-31/32" (L) x 1-3/16" (W).3 kg.66 Lbs 36 mm 14-11/64".8 Electric Current.4 (mmhg) (in.hg) (kgf/cm 22.8 pick up and place devices for CD & DVD 48 Red (+) (.) ø Black (-) 2 x ø3. View A 38 3 (2) (8.7) ø38 ø Insulated Rubber Feet (1 ) A (8.) 79

81 Compressor and Pump DIAPHRAGM DP11-Y1 Brushless DC Motor 24 V DC & Power Consumption (A) Characteristics (mmhg) (kgf/cm 2 ) (in.hg) Current Characteristics Attainable Free Air Displacement Rated Voltage Maximum Pressure Maximum Current AR (MTTF) Coil Insulation Class kpa (- mmhg) -667 mbar in.hg 7. L/min.26 cfm 24 V DC kpa (1. kgf/cm 2 ) 1. bar 21.7 psig.6 A or less, hours 6 mm O.D. straight barb 6 mm O.D. straight barb A or its equivalent (JETL) (L) x 3 (W) mm 1-31/32" (L) x 1-3/16" (W).3 kg.66 Lbs 36 mm 14-11/64". 4 Electric Current. 2 (mmhg) (in.hg) (kgf/cm 2 ) 22.8 pick up and place devices for CD & DVD 48 Red (+) (.) ø6 14 Black (-) 38 3 (8.7) x ø3. View A (2) ø38 ø Insulated Rubber Feet (1 ) A (8.) 8

82 Compressor and Pump DIAPHRAGM DP11-X3 Brushless DC Motor 12 V DC PWM control possible & Power Consumption (A) Characteristics (mmhg) (kgf/cm 2 ) (in.hg) Current Characteristics Control Range Control Range Attainable Free Air Displacement Rated Voltage Maximum Pressure Maximum Current (MTTF) kpa (- mmhg) -667 mbar in.hg 7. L/min.26 cfm 12 V DC kpa (1. kgf/cm 2 ) 1. bar 21.7 psig 1.4 A or less, hours Control(PWM) 2. - V, -2 khz, Duty cycle 8-1% 6 mm O.D. straight barb 6 mm O.D. straight barb Coil Insulation Class A or its equivalent (JETL) (L) x 3 (W) mm 1-31/32" (L) x 1-3/16" (W).3 kg.66 Lbs 18 mm 7-3/32".8 Electric Current.4 (mmhg) (in.hg) (kgf/cm 2 ) 22.8 pick up and place devices for CD & DVD Mounting Dimension of Rubber Foot: Plate thickness : t = 2 mm, Hole diameter : ø mm (Rubber feet come with the product as accessories.) ø Red (+) Blue PWN Signal (In) 2. - V - 2 khz Yellow Pulse Signal (Out) 2 x ø3. View A 38 (8.7) (.) ø38 ø (2) Insulation Rubber Feet (1 ) A (8.) 81

83 Compressor and Pump DIAPHRAGM DP11T-X1 Brushless DC Motor 12 V DC & Power Consumption (mmhg) (in.hg) (A) Characteristics Current Characteristics (kgf/cm 2 ) 22.8 Attainable Free Air Displacement Rated Voltage Maximum Pressure Maximum Current AR (MTTF) Coil Insulation Class -6. kpa (-4 mmhg) -6 mbar in.hg. L/min.194 cfm 12 V DC kpa (1. kgf/cm 2 ) 1. bar 21.7 psig 1.2 A or less, hours 6.8 mm O.D. straight barb 6.8 mm O.D. straight barb A or its equivalent (JETL) 36. (L) x 37. (W) mm 1-7/16" (L) x 1-/32" (W).27 kg.6 Lbs 36 mm 14-11/64".8 Electric Current (mmhg) (in.hg) (kgf/cm 2 ) 22.8 Vending Machines 4 x M3 with 4 mm Depth Black (-) 63 ø38 ø Red (+) 37. View B Lead Wire Position (12) 71 (2) View A (ø6.8) 3 B (1.6) A 82

84 Compressor and Pump DIAPHRAGM DP11T-Y1 Brushless DC Motor 24 V DC & Power Consumption (A) Characteristics (mmhg) (kgf/cm 2 ) (in.hg) Current Characteristics Attainable Free Air Displacement Rated Voltage Maximum Pressure Maximum Current (MTTF) Coil Insulation Class -6. kpa (-4 mmhg) -6 mbar in.hg. L/min.194 cfm 24 V DC kpa (1. kgf/cm 2 ) 1. bar 21.7 psig.6 A or less, hours 6.8 mm O.D. straight barb 6.8 mm O.D. straight barb A or its equivalent (JETL) 36. (L) x 37. (W) mm 1-7/16" (L) x 1-/32" (W).27 kg.6 Lbs 36 mm 14-11/64" Electric Current.1 (mmhg) (in.hg) (kgf/cm 2 ) 22.8 Vending Machines 4 x M3 with 4 mm Depth Black (-) 63 ø38 ø Red (+) 37. View B Lead Wire Position (12) 71 (2) View A (ø6.8) 3 B (1.6) A 83

85 Compressor and Pump DIAPHRAGM DP21T-X1 Brushless DC Motor 12 V DC & Power Consumption (A) Characteristics (mmhg) (kgf/cm 2 ) (in.hg) Current Characteristics Attainable Free Air Displacement Rated Voltage Maximum Pressure Maximum Current AR (MTTF) Coil Insulation Class -6. kpa (-4 mmhg) -6 mbar in.hg 1 L/min.3 cfm 12 V DC kpa (1. kgf/cm 2 ) 1. bar 21.7 psig 1.6 A, hours 6.8 mm O.D. straight barb 6.8 mm O.D. straight barb B or its equivalent 36. (L) x 37. (W) mm 1-7/16" (L) x 1-/32" (W).32 kg.71 Lbs 3 mm 11-13/16".8 Electric Current (mmhg) (in.hg) (kgf/cm 2 ) 22.8 Vending Machines 4 x M3 with 4 mm Depth Black (-) 67. ø38 ø36 7. Red (+) 37. (2) ø6.8 (1.) 38 (48.) (12) 73 View A (ø36) (1) 3 (24) (11) A Insulated Rubber Feet 84

86 Compressor and Pump DIAPHRAGM DP21T-Y1 Brushless DC Motor 24 V DC & Power Consumption (mmhg) (in.hg) (A).7.6. Characteristics Current Characteristics (kgf/cm 2 ) 22.8 Attainable Free Air Displacement Rated Voltage Maximum Pressure Maximum Current (MTTF) Coil Insulation Class -6. kpa (-4 mmhg) -6 mbar in.hg 1 L/min.3 cfm 24 V DC kpa (1. kgf/cm 2 ) 1. bar 21.7 psig.8 A, hours 6.8 mm O.D. straight barb 6.8 mm O.D. straight barb B or its equivalent 36. (L) x 37. (W) mm 1-7/16" (L) x 1-/32" (W).32 kg.71 Lbs 3 mm 11-13/16" Electric Current.1 (mmhg) (in.hg) (kgf/cm 2 ) 22.8 Vending Machines 4 x M3 with 4 mm Depth Black (-) 67. ø38 ø36 7. Red (+) 37. (12) 73 (2) View A ø6.8 (ø36) (1) (1.) 38 (48.) 3 (24) (11) A Insulated Rubber Feet 8

87 Pump PISTON DP41-X1 Brushless DC Motor 12 V DC & Power Consumption (A) Characteristics Current Characteristics ø (83) 7 4 Rc1/8 Rc1/8 (2) (28) A 114. (22) (137) Position of the Cable Tie Detail A Circuit No (4). Connection Table Source Control Signal Circuit No Cord Color Red Black Orange Green Gray Function V+ V- DRIVE /FREE PULSE ALARM SPEED SGND Option ON OFF Function On ON ON Cord Size AWG2 AWG22 Line Type UL17 *Control function is OFF by default. detail A.) If they are not secured, poor contact of the connector may occur and result in failure (mmhg) (in.hg) Attainable Free Air Displacement Rated Voltage Maximum Current (MTTF) AR Coil Insulation Class kpa (-8 mmhg) -773 mbar in.hg 18 L/min.64 cfm 12 V DC 2. A or less 1, hours Rc1/8 Rc1/8 E or its equivalent (JETL) 7 (L) x 4 (W) mm 2-3/4" (L) x 1-49/64" (W) 1.1 kg 2.4 Lbs 28 mm 11-7/32" Electric Current (sec) Exhaust Characteristics (mmhg) (in.hg) with 1 L tank Air Cylinder/Chuck Driver 4 Time (mmhg) (in.hg) 86

88 Pump PISTON DP41-Y1 Brushless DC Motor 24 V DC & Power Consumption Characteristics Current Characteristics Attainable Free Air Displacement Rated Voltage Maximum Current (MTTF) AR Coil Insulation Class kpa (-8 mmhg) -773 mbar in.hg 18 L/min.64 cfm 24 V DC 1. A or less 1, hours Rc1/8 Rc1/8 E or its equivalent (JETL) 7 (L) x 4 (W) mm 2-3/4" (L) x 1-49/64" (W) 1.1 kg 2.43 Lbs 28 mm 11-7/32" Air Cylinder/Chuck Driver ø Rc1/8 Rc1/ (83) (2) (28) A 114. (22) (137) Position of the Cable Tie Detail A Circuit No (4). Connection Table Source Control Signal Circuit No Cord Color Red Black Orange Green Gray Function V+ V- DRIVE /FREE PULSE ALARM SPEED SGND Option ON OFF Function On ON ON Cord Size AWG2 AWG22 Line Type UL17 *Control function is OFF by default. detail A.) If they are not secured, poor contact of the connector may occur and result in failure.. (A) (mmhg) (in.hg) Electric Current (sec) Exhaust Characteristics (mmhg) (in.hg) with 1 L tank 4 Time (mmhg) (in.hg) 87

89 Compressor PISTON DP41-X2 Brushless DC Motor 12 V DC & Power Consumption (A) Characteristics Current Characteristics AR Air Cylinder/Chuck Driver ø (83) 7 4 Rc1/8 Rc1/8 (2) (28) A 114. (22) (137) Position of the Cable Tie Detail A Circuit No (4). Connection Table Source Control Signal Circuit No Cord Color Red Black Orange Green Gray Function V+ V- DRIVE /FREE PULSE ALARM SPEED SGND Option ON OFF Function On ON ON Cord Size AWG2 AWG22 Line Type UL17 *Control function is OFF by default. detail A.) If they are not secured, poor contact of the connector may occur and result in failure (kgf/cm 2 ) 42.7 Free Air Displacement Rated Voltage Maximum Pressure Maximum Current Working Pressure Range 18 L/min.64 cfm 12 V DC 18 kpa (1.8 kgf/cm 2 ) 1.8 bar 26.1 psig. A to 18 kpa ( to 1.8 kgf/cm 2 ) to 1.8 bar to 26.1 psig (MTTF) 1, hours ISO RC 1/8 ISO RC 1/8 Coil Insulation Class E or its equivalent (JETL) 7 (L) x 4 (W) mm 2-3/4" (L) x 1-49/64" (W) 1.1 kg 2.4 Lbs 28 mm 11-7/32" Electric Current (kgf/cm 2 )

90 Compressor PISTON DP41-Y2 Brushless DC Motor 24 V DC & Power Consumption (A) Characteristics Current Characteristics AR Air Cylinder/Chuck Driver ø (83) 7 4 Rc1/8 Rc1/8 (2) (28) A 114. (22) (137) Position of the Cable Tie Detail A Circuit No (4). Connection Table Source Control Signal Circuit No Cord Color Red Black Orange Green Gray Function V+ V- DRIVE /FREE PULSE ALARM SPEED SGND Option ON OFF Function On ON ON Cord Size AWG2 AWG22 Line Type UL17 *Control function is OFF by default. detail A.) If they are not secured, poor contact of the connector may occur and result in failure (kgf/cm 2 ) 42.7 Free Air Displacement Rated Voltage Maximum Pressure Maximum Current Working Pressure Range 18 L/min.64 cfm 24 V DC 18 kpa (1.8 kgf/cm 2 ) 1.8 bar 26.1 psig 2.7 A to 18 kpa ( to 1.8 kgf/cm 2 ) to 1.8 bar to 26.1 psig (MTTF) 1, hours ISO RC 1/8 ISO RC 1/8 Coil Insulation Class E or its equivalent (JETL) 7 (L) x 4 (W) mm 2-3/4" (L) x 1-49/64" (W) 1.1 kg 2.4 Lbs 28 mm 11-7/32" Electric Current (kgf/cm 2 )

91 Pump PISTON DP41T-Y1 Brushless DC Motor 24 V DC & Power Consumption (A) Characteristics Current Characteristics Attainable Free Air Displacement Rated Voltage Maximum Current (MTTF) AR Coil Insulation Class kpa (-8 mmhg) -773 mbar in.hg 34 L/min 1.2 cfm 24 V DC 2. A, hours Rc1/8 Rc1/8 E or its equivalent (For DC motor) 166 (L) x 84 (W) mm 6-17/32" (L) x 3-/16" (W) 1.6 kg 3. Lbs 28 mm 11-7/32" Air Cylinder/Chuck Driver (99) (26.) (84) 7 (166) 1. Ø Rc1/8 IN (2) (28) Rc1/8 OUT +PAN HEAD SCREW M3 18 Rc1/8 IN Slide switch Rc1/8 OUT (16) (113).177 (mmhg) (in.hg) Electric Current 1. (sec) Exhaust Characteristics (mmhg) (in.hg) with 1 L tank 3 2 Time (mmhg) (in.hg) (22) Circuit No Position of the Cable Tie Detail A Connection Table Source Control Signal Circuit No Cord Color Red Black Orange Green Gray Function V+ V- DRIVE /FREE PULSE ALARM SPEED SGND Option ON OFF Function On ON ON Cord Size AWG2 AWG22 Line Type UL17 *Control function is OFF by default. detail A.) If they are not secured, poor contact of the connector may occur and result in failure. A 9

92 Compressor PISTON DP41T-Y2 Brushless DC Motor 24 V DC & Power Consumption (A) Characteristics Current Characteristics Air Cylinder/Chuck Driver ø (83) 7 4 Rc1/8 Rc1/8 (2) (28) A 114. (22) (137) Position of the Cable Tie Detail A Circuit No (4). Connection Table Source Control Signal Circuit No Cord Color Red Black Orange Green Gray Function V+ V- DRIVE /FREE PULSE ALARM SPEED SGND Option ON OFF Function On ON ON Cord Size AWG2 AWG22 Line Type UL17 *Control function is OFF by default. detail A.) If they are not secured, poor contact of the connector may occur and result in failure (kgf/cm 2 ) 42.7 Free Air Displacement Rated Voltage Maximum Pressure Maximum Current Working Pressure Range 34 L/min 1.2 cfm 24 V DC kpa (1. kgf/cm 2 ) 1. bar 21.7 psig 4. A to kpa ( to 1. kgf/cm 2 ) to 1. bar to 21.7 psig (MTTF), hours RC 1/8 RC 1/8 Coil Insulation Class E or its equivalent (For DC motor) 166 (L) x 84 (W) mm 6-17/32" (L) x 3-/16" (W) 1.6 kg 3. Lbs 28 mm 11-7/32" Electric Current (kgf/cm 2 )

93 LIQUID PUMP Piezoelectric Pump BPS Type BPH Type BPHS Type BPF Type Page - 93 Page DC Diaphragm Liquid Pump DPE-1 DPE-4 DPE-4BL DPE

94 Piezoelectric Pump BIMOR PUMP Compact, lightweight, durable & quiet As the Bimorph has no motors or shafts or other troublesome mechanisms. We have achieved maintenance free continuous operation for 6 months. Suitable for pumping liquids Low power consumption & electromagnetic noise The Bimor is driven by low energy consuming piezoelectric elements. Consequently it costs very little to run and emits virtually no electromagnetic noise. Simple flow rate adjustment As the flow rate of the Bimor is proportional to the voltage and frequency, adjusting the flow rate is as simple as adjusting either one. You may use the product at the rated voltage or lower. Application versatility The parts can be made of several different materials, so you can select the material appropriate to your needs, be it a liquid application. The Bimor is currently employed in a variety of different fields including medicine, scientific research, and the PC and chemical industries. Applications For supply and drainage For cooling circulation For medical injection For liquid sampling Dimensional Outline Drawing (Unit: mm) BPS type ø3.1 ø ø4 ø BPHS type 7 ø7. ø6 ø Lead Wires L=3 BIMOR Lead Wires L= BPH type ø4.3 7 ø7. ø6 ø9 BPF type ø ø8.2 Rc1/8 Taper Thread Tube Fitting Outer Diameter 6 mm Lead Wires L=1 ø (26) 33 Lead Wires L=

95 BIMOR BPS Type BPH Type BPHS Type BPHS Type Current (ma) Voltage(AC) Self-priming Pressure 12 V 6Hz FlowRate (ml/min) Discharge Pressure Voltage(AC) Current (ma) Self-priming Pressure 23 V Hz FlowRate (ml/min) Discharge Pressure Liquid Surface Materials Housing Liquid Contact Sheet Valve/O-ring (g) BPS-2i PP PP IIR 4 BPH-214E BPH-214G BPH-214E BPH-214G PP PP PTFE EPDM FKM 14 BPH-414E PP EPDM BPH-274G BPH-274P PPS PTFE FKM FFKM FEP 17 Voltage(AC) 1 V 6Hz Liquid Surface Materials Current Self-priming FlowRate Discharge Pressure Liquid (ma) Pressure (ml/min) Housing Contact Sheet Valve O-ring BPHS-414i IIR PP BPHS-414E 12 7 PP EPDM BPHS-414G FKM 3 3 BPHS-474G FKM PTFE 1 PPS BPHS-474P FFKM FFKM FEP (g) 18 Material Description EPDM FEP FFKM FKM IIR PP PTFE Ethylene Propylene Rubber Fluoroethylene Propylene Fluorine Rubber (Perfluoro) Fluorine Rubber Butyl Rubber Polypropylene Tetrafluororesin (Polytetrafluoroethylene) suitable/unsuitable chemical liquids Examples of suitable chemical liquids Examples of unsuitable chemical liquids BPS-2i BPHS-414i BPH-214E BPH-414E BPHS-414E BPH-214G BPHS-414G Ethanol,Dilute hydrochloric acid, Sodium carbonate,benzaldehyde,formalin Ammonia water, Ethanol, Hydrochloric acid, Caustic potash, Caustic soda, Methanol Ethanol, Dilute hydrogen peroxide, Mineral oil, Sodium hypochlorite Xylene,Mineral oil,carbon tetrachloride, Trichloroethylene,Toluene,Benzene Acetone, Ammonia water, Glacial acetic acid, Hydrofluoric acid, Formalin BPH-274G BPHS-474G Ethanol, Xylene, Carbon tetrachloride, Silicone oil, Trichloroethylene Acetone, Ammonia water, Chlorosulfonic acid, Glacial acetic acid, Hydrofluoric acid, Formalin BPH-274P BPHS-474P Ethanol, Chloroform, Glacial acetic acid, Benzene, Methyl ethyl ketone Chlorosulfonic acid, Fluorine oil, CFC 112, CFC

96 Piezoelectric Pump BIMOR PUMP Made to order model These models are made-to-order model. Please ask your nearest distributor about cost. The minimum order quantity is 3 units. BPS Type BPH Type BPF Type Current (ma) Voltage(AC) Self-priming Pressure 12 V 6Hz FlowRate (ml/min) Discharge Pressure BPS-2i Voltage(AC) Current (ma) Self-priming Pressure 23 V Hz FlowRate (ml/min) Discharge Pressure Liquid Surface Materials Liquid Housing Contact Sheet Valve/O-ring PP PP IIR (g) BPH-214i BPH-414D BPH-414G BPH-474G BPH-474P BPF-46P BPH-214i BPH-214D BPF-26P PP PPS PFA PP PTFE IIR VMQ FKM FFKM FEP Material Description FFKM FKM IIR POM Fluorine Rubber (Perfluoro) Fluorine Rubber Butyl Rubber Polyacetal PFA PP PTFE VMQ Fluororesin (Perfluoroalkoxy) Polypropylene Tetrafluororesin (Polytetrafluoroethylene) Dimethyl Silicon Rubber suitable/unsuitable chemical liquids BPS-2i BPH-214i BPH-214D BPH-414D BPH-414G BPH-474G BPH-474P BPF-46P BPF-26P Examples of suitable chemical liquids Ethanol,Dilute hydrochloric acid, Sodium carbonate, Benzaldehyde, Formalin Ammonia water, Ethanol, Dilute hydrogen peroxide, Sodium hypochlorite, Methanol Ethanol, Hydrogen peroxide, Mineral oil, Sodium hypochlorite Ethanol, Xylene, Carbon tetrachloride, Silicone oil, Trichloroethylene Ethanol, Chloroform, Glacial acetic acid, Benzene, Methyl ethyl ketone Ethanol, Aqua regia, Ozone, Carbon tetrachloride, Concentrated nitric acid, Concentrated sulfuric acid, Fuming sulfuric acid Examples of unsuitable chemical liquids Xylene, Mineral oil, Carbon tetrachloride, Trichloroethylene, Toluene, Benzene Caustic soda, Carbon tetrachloride, Silicone oil, Trichloroethylene, Toluene, Benzene Acetone, Ammonia water, Glacial acetic acid, Hydrofluoric acid, Formalin Acetone, Ammonia water, Chlorosulfonic acid, Glacial acetic acid, Hydrofluoric acid, Formalin Chlorosulfonic acid, Fluorine oil, CFC 112, CFC 113 Fluorine oil, CFC 112, CFC 113 9

97 BIMOR The Next Step in Pump Miniaturization Revolutionary piezoelectric bimorph technology The Bimor's driving force, the bimorph, comprises two parallel piezoelectric wafers. Their nature is to expand or contract depending on the direction of the voltage. Therefore when an alternating current is applied, one wafer expands then contracts while the other contracts then expands, causing the bimorph to bend. Repeating the cycle creates the pumping action. Cross section O-ring and Valves O-ring Liquid Contact Sheet Bimorph Vibrator Elastic Mold Principle / Structure "The Bimor pump" uses the displacement operation of the piezoelectric bimorph vibrator as the direct source of the pumping action. Driving Power : Piezoelectric Bimorph Winding Suction Expulsion and Valves Piezoelectric Bimorph 96

98 DC Liquid Pump DIAPHRAGM DPE series DPE-4 Built-in Pulse Absorption Chamber Self-priming type with air suction acceptable DPE-1 Typical Conventional Pump without Pulse Absorption As liquid is transported through the suction and discharge passages of the pump and liquid circuit, high pulsations can vibration in tubing, fittings, peak pulsing mechanisms. These negative results are often increased through the use of small pumps having relatively high rotational speeds. Suction AR Discharge Suction Motor Rotation Direction Discharge Suction Crank Angle 36 Advanced design DPE Pump with Pulse Absorption vibration throughout the fluid circuit, and enhances life of the pump and other circuit pulsation dampers. Pulse Absorption Chamber Suction 2 absorption chamber, not directly forced to outlet port. Suction Motor Rotation Direction Discharge Suction Discharge 3 Discharge Pulses are attenuated through the process of 2 and 3. Suction Crank Angle

99 DC Liquid Pump DIAPHRAGM DPE-1 Brush DC Motor 24 V DC Flow & Electric Current Flow (ml (A Electric Current Self-priming Pressure Self-priming Pressure Current Characteristics (in.hg) (in.hg) Rated Voltage 1 Working Pressure Range Maximum Pressure * 2 Maximum Current AR (MTTF) * 2 Self-priming Pressure * 1 Motor Build materials and applicable fluids Cylinder Head Head Cover DPE-1-2E DPE-1-2G DPE-1-7G DPE-1-7P PA Polyamide(Nylon) PPS Polyphenylene sulfide Diaphragm PTFE Polytetrafluoroethylene 24 V DC 1 ml/min.3 cfm to 1 kpa to 1 bar to 14. psig 3 kpa 3 bar 43. psig 1 ma hours 2 kpa.2 bar 2.9 psig 4.7 mm O.D. straight barb 4.7 mm O.D. straight barb E class equivalent 9. (L) x 17 (W) mm 3/8"(L) x 43/64"(W) 67 g.148 Lbs Brush DC Motor *1. Valve O-ring Applicable fluids EPDM Sodium hydroxide, Citric acid Ethylene-propylene rubber Ammonia water, Caustic potash FKM Fuluoro rubber Ethanol, Ethylene glycol Sodium carbonate, mineral oil Xylene, Carbon tetrachloride Trichloroethylene, Silicon oils FFKM Chloroform, Benzene Perfluoroelastomer Glacial acetic acid, Methyl ethyl ketone DC Power Input Terminal (-) 1 2 x ø3.2, Effective Depth 1 mm x ø3.2, Effective Depth 1 mm x M3 with mm Depth ø DC Power Input Terminal (+) 98

100 DC Liquid Pump DIAPHRAGM DPE-4 Brush DC Motor 24 V DC Flow & Electric Current Flow (ml (A Electric Current Self-priming Pressure Self-priming Pressure Current Characteristics (in.hg) (in.hg) Rated Voltage 1 Working Pressure Range Maximum Pressure * 2 Maximum Current (MTTF) Self-priming Pressure Motor Build materials and applicable fluids 24 V DC 4 ml/min.141 cfm to 1 kpa to 1 bar to 14. psig 3 kpa 3 bar 43. psig 34 ma hours 4 kpa.4 bar.8 psig.4 mm O.D. straight barb.4 mm O.D. straight barb F class equivalent 19 (L) x 26 (W) mm 3/4"(L) x 1-1/32"(W) 187 g.412 Lbs Brush DC Motor *1. Cylinder Head Head Cover DPE-4-2E PA DPE-4-2G Polyamide(Nylon) DPE-4-7G DPE-4-7P PPS Polyphenylene sulfide Diaphragm PTFE Polytetrafluoroethylene Valve O-ring Applicable fluids EPDM Sodium hydroxide, Citric acid Ethylene-propylene rubber Ammonia water, Caustic potash FKM Fuluoro rubber FFKM Perfluoroelastomer Ethanol, Ethylene glycol Sodium carbonate, mineral oil Xylene, Carbon tetrachloride Trichloroethylene, Silicon oils Chloroform, Benzene Glacial acetic acid, Methyl ethyl ketone 1 12 DC Power Input Terminal (-) DC Power Input Terminal (+) x M3 with mm Depth ø32.8 ø ø ø

101 DC Liquid Pump DIAPHRAGM DPE-4BL Brushless DC Motor 24 V DC Flow & Electric Current Flow (ml (A Electric Current (in.hg) Self-priming Pressure Self-priming Pressure Current Characteristics (in.hg) Rated Voltage 1 Working Pressure Range Maximum Pressure * 2 Maximum Current AR (MTTF) * 2 Self-priming Pressure * 1 Motor Build materials and applicable fluids Cylinder Head Head Cover DPE-4BL-2E DPE-4BL-2G DPE-4BL-7G DPE-4BL-7P PA Polyamide(Nylon) PPS Polyphenylene sulfide Diaphragm PTFE Polytetrafluoroethylene 24 V DC 4 ml/min.141 cfm to 1 kpa to 1 bar to 14. psig 3 kpa 3 bar 43. psig 4 ma 6, hours 4 kpa.4 bar.8 psig.4 mm O.D. straight barb.4 mm O.D. straight barb A class equivalent 41 (W) mm 1-39/64 "(W) 23 g.7 Lbs Brushless DC Motor *1. *2. Pumps may not re-start against high backpressure. Valve O-ring Applicable fluids EPDM Sodium hydroxide, Citric acid Ethylene-propylene rubber Ammonia water, Caustic potash FKM Fuluoro rubber Ethanol, Ethylene glycol Sodium carbonate, mineral oil Xylene, Carbon tetrachloride Trichloroethylene, Silicon oils FFKM Chloroform, Benzene Perfluoroelastomer Glacial acetic acid, Methyl ethyl ketone Red Wire Vm (+) x Cross Recessed Head Screw M3 3.6 Black Wire GND 4 ø.4 21 A 4 x M3 with 4. mm Depth ø3.8 ø ( ) View A 1

102 DC Liquid Pump DIAPHRAGM DPE-8 Brush DC Motor 24 V DC DPE-8-7P DPE-8-7G DPE-8-2G DPE-8-2E Flow & Electric Current Flow (ml (A Electric Current Self-priming Pressure Self-priming Pressure Current Characteristics (in.hg) (in.hg) Rated Voltage 1 Working Pressure Range Maximum Pressure * 2 Maximum Current (MTTF) Self-priming Pressure Motor Build materials and applicable fluids 24 V DC 8 ml/min.283 cfm to 1 kpa to 1 bar to 14. psig 3 kpa 3 bar 43. psig 6 ma 6 hours 4 kpa.4 bar.8 psig.4 mm O.D. straight barb.4 mm O.D. straight barb E class equivalent 74. (L) x 41 (W) mm 2-/16"(L) x 1-39/64"(W) 3 g.771 Lbs Brush DC Motor *1. Cylinder Head Head Cover DPE-8-2E PA DPE-8-2G Polyamide(Nylon) DPE-8-7G DPE-8-7P PPS Polyphenylene sulfide Diaphragm PTFE Polytetrafluoroethylene Valve O-ring Applicable fluids EPDM Sodium hydroxide, Citric acid Ethylene-propylene rubber Ammonia water, Caustic potash FKM Fuluoro rubber FFKM Perfluoroelastomer Ethanol, Ethylene glycol Sodium carbonate, mineral oil Xylene, Carbon tetrachloride Trichloroethylene, Silicon oils Chloroform, Benzene Glacial acetic acid, Methyl ethyl ketone ø.4 Terminal (+) Terminal (-) ø (3) (93) x Pan Head Phillips Screw M x M3 with 4. mm Depth

103 LA BLOWER Page AC Linear Free Piston Blower LA-28B LA-4C LA-6B LA-8B LA-1A LA-12A LAM- LAM

104 Blower AR LA-28B & LA-4C 12V (6Hz) 23/24V (Hz) LA-28B 23V (Hz) LA-4C Characteristics Hz LA-28B 6Hz (bar) LA-28B LA-4C 12 V AC 23/24 V AC 12 V AC 23/24 V AC Rated Frequency 6 Hz Hz 6 Hz Hz 2. W 29 W 4 W 47 W 11 kpa (.11 kgf/cm 2 ) Rated Pressure.11 bar 1.9 psig 28 L/min 4 L/min.99 cfm 1.9 cfm AR Optional Hose Assemblies LB kg 6.4 Lbs LA kg 7.1 Lbs LA-4C Liquid Mixer Bubbling LA-28B LA-4C ø ø Hz Hz (bar) 13

105 Blower AR LA-6B & LA-8B 12V (6Hz) 23V (Hz) LA-6B 23/24V (Hz) LA-8B Characteristics LA-6B AR LA-8B Liquid Mixer Bubbling Home Aerobic Sewage Treatment System ø Hz Hz (bar) LA-6B LA-8B 12 V AC 22/23/24 V AC 12 V AC 22/23/24 V AC Rated Frequency 6 Hz Hz 6 Hz Hz 6 W 64 W 8 W 86 W kpa (. kgf/cm 2 ) Rated Pressure. bar 2.17 psig 6 L/min 8 L/min 2.12 cfm 2.83 cfm Optional Hose Assemblies LB318. kg 11 Lbs LA kg 11.7 Lbs 1 9 6Hz Hz (bar)

106 Blower AR LA-1A & LA-12A 23V (Hz) LA-1A 23/24V (Hz) LA-12A Characteristics LA-1A 6Hz Hz AR LA-12A Liquid Mixer Bubbling Home Aerobic Sewage Treatment System ø (bar) LA-1A LA-12A 12 V AC 23/24 V AC 12 V AC 23/24 V AC Rated Frequency 6 Hz Hz 6 Hz Hz 9 W 1 W 118 W 13 W 18 kpa (.18 kgf/cm 2 ) Rated Pressure.18 bar 2.6 psig 1 L/min 12 L/min 3.3 cfm 4.24 cfm 9.7 kg 21.4 Lbs Optional Hose Assemblies LB396 LB Hz 2.2 Hz (bar)

107 AR Blower LAM- & LAM-2 12V 23V (6Hz) (Hz) 23/24V (Hz) LAM-2 LAM- Characteristics Hz V^LY :\WWS` Rated Frequency 7V^LY *VUZ\TW[PVU LAM- Rated Pressure 9H[LK (PYÅV^ AR LAM- LAM-2 23 V AC 12 V AC 23/24 V AC Hz 6 Hz Hz 14 W 2 W 2 kpa (.2 kgf/cm2).2 bar 2.9 psig L/min 2 L/min.3 cfm 7.6 cfm 12.3 kg 12.3 kg 27.1 Lbs 27.1 Lbs Optional Hose Assemblies 2.83 (bar) LB396 LB LAM Hz Grease Trap 6Hz Home Aerobic Sewage Treatment System 4.94 (bar) Dimensional Outline Drawing (Unit : mm) ø

108 17

109 OTHER PRODUCTS LINICON (VACUUM PUMP) Page LV-12A - 19 LV-12A 18

110 LINICON ( Pump) AR LV-12A Oil-less Compressor AC linear free piston vacuum pump Equipped with fuse and removable power cable Compact and lightweight Low noise level Oil-less construction Rated Voltage 1 V AC 23 V AC Consumption 14 W W Rated Frequency 6 Hz Hz Maximum kpa (-2 mm Hg, -333 mbar, in. Hg) Dimensions 13 (L) x 91 (W) x 146 (H) mm (-/16" x 3-37/64" x -3/4") Coil Insulation Class B or its equivalent E or its equivalent 1. kg (3.3 Lbs) Pick-Up Set the Pick-Up Set can be arranged. LB7629 pen assembly LQ1267 Tube 3 x x 2 LA71242 Needle 1 x 1. x 4 (6 pcs/set) LA7121 Pad 6 mm dia. LA71249 Pad 4 mm dia. LA71143 Pen stand High Adsorption Power In the case that the depth of vacuum is kpa (-2 mmhg) and Pad Diameter A B placed vertically and moved laterally. 4 mm 2 g 1 g 6 mm g 2 g LV-12A Pen Stand Pen Assembly 2 x 7.8 x 2/736 A is calculated by multiplying the safety rate of. to the above equation, and then rounded. B is calculated by multiplying the safety rate of.2 to the above equation, and then rounded. D mm Transferring spherical objects such as balls Assembling precision parts Moving tiny parts Transferring uneven parts 19

111 Cuplas, Quick Connect Couplings, Enable Flexible, Fast, and Secure Connections in Various Fluid Lines. Plastic Cupla BC Type Valveless For low pressure air piping Working pressure Valve structure Applicable fluid Cube Cupla Small and lightweight coupling for air supply lines to medical and/or scientific equipment Working pressure Valve structure Applicable fluids.7 MPa {.7 kgf/cm 2 } Air.7 MPa Air Straight through {.7 kgf/cm 2 } Two-way shut-off One-way shut-off Straight through To connect, just push the plug into the socket. Plastic makes this ideal for use in environment prone to rusting. Compact and light weight for easy handling. Valveless construction gives more stable flow. Water Ultra-lightweight, made of polyacetal resin. Compact design for space saving. Just push plug into socket for connection. Simply press the button on the socket for disconnection. Both socket and plug have built-in valve types and valveless types. Valveless structure suits high viscosity fluids. Suitable for a wide range of applications from medical/scientific equipment to beverage machines or semiconductor manufacturing devices. Micro Cupla For piping in pneumatic control devices Working pressure Valve structure Applicable fluids Small Cupla Lightweight and compact for use on air lines and scientific equipment Working pressure Valve structure Applicable fluids 1. MPa Air.7 MPa Air Water {1 kgf/cm 2 } One-way shut-off {7 kgf/cm 2 } One-way shut-off Even though the valve is built in the socket, the sleeve outer diameter is confined to 9. mm. Compact design for piping in narrow spaces. Push-to-connect operation. Tube Fitter type for even easier tube insertion. Plated brass and stainless bodies are available for excellent corrosion resistance. Available in various end configurations to satisfy a wide range of pneumatic applications. Light, compact for air piping connections Super Cupla Hi Cupla 2 Water Compact socket with built-in valve and 14 mm OD sleeve. Just push in the plug to the socket for connection. Also available with quick connect/disconnect Tube Fitter type. Chrome-plated brass for corrosion resistance adopted for the body. Available in various end configurations to satisfy a wide range of pneumatic applications. Push-to-connect type for air lines Working pressure Valve structure Applicable fluid Working pressure Valve structure Applicable fluid 1. MPa Air 1. MPa Air {1 kgf/cm 2 } { kgf/cm One-way shut-off 2 } One-way shut-off Lightweight design suits direct connection to power tools. Push-to-connect for easy operation. Also available with quick connect/disconnect Tube Fitter type. Chrome-plated steel for corrosion resistance adopted for the body. (Partly aluminum) Available in various end configurations for a wide range of pneumatic applications. Just push the plug into the socket for simple and secure connection. New valve design for low pressure loss to achieve flow rate increase (% up over the conventional model). End-face seal is achieved when connected. Enhanced operability with low connection resistance. End-face seal design is superior to external seal with an O-ring due to no seal damage caused by exhausted lubrication. Also available with quick connect/disconnect Tube Fitter type. Hi Cupla Universal purpose couplings for air lines Working pressure Valve structure Applicable fluids (Steel applies to air only) Hi Cupla Ace Lightweight plastic coupling with automatic safety lock for air line applications Working pressure Valve structure Applicable fluids 1. MPa 1. MPa Air 1. MPa Air { kgf/cm 2 } {1 kgf/cm 2 } Water { kgf/cm One-way shut-off 2 } One-way shut-off An excellent general purpose coupling for connecting factory air supply to pneumatic tools. Steel coupling is suitable for air. Brass or stainless steel is suitable for water. Critical structural parts of steel models are heat-treated for increased strength giving greater durability and resistance to wear. Available in various body materials, sizes and end configurations applicable to a wide range of applications. Water Pressure ratings comparable to steel Cuplas. A built in automatic lock mechanism locks the sleeve upon connection, thus prevents accidental disconnection. Just push plug into socket for simple connection. The weight is a quarter of steel Hi Cupla for easy handling. Can be used for air and water. For more information, please visit and see our ecatalog here. 11

AIR COMPRESSOR, VACUUM PUMP & LIQUID PUMP

AIR COMPRESSOR, VACUUM PUMP & LIQUID PUMP Lk1f Linear-motor-driven Free Piston Pumps and other Pumps for various applications AIR COMPRESSOR, VACUUM PUMP & LIQUID PUMP GENERAL CATALOG Our air compressors and vacuum pumps are unique products featuring

More information

Seven Features of the Koganei Vacuum Valve

Seven Features of the Koganei Vacuum Valve Seven Features of the Koganei Valve Koganei Original Solenoid Construction No burning damage to solenoid No need to stock solenoids as spare parts. Starting and energizing current values are extremely

More information

DIAPHRAGM PUMPS. SLL series 8 EL-N series 9 EL-S series single system 10 EL-S series twin system 11 OEM assembly pumps 12 Phoe-niX series 14

DIAPHRAGM PUMPS. SLL series 8 EL-N series 9 EL-S series single system 10 EL-S series twin system 11 OEM assembly pumps 12 Phoe-niX series 14 Bild fehlt noch DIAPHRAGM PUMPS SLL series 8 EL-N series 9 EL-S series single system 1 EL-S series twin system 11 OEM assembly pumps 12 Phoe-niX series 14 5 Applications Water treatment and environmental

More information

3-in-1 package (solenoid valve + governor + solenoid valve) realizes compact piping in double shutoff application.

3-in-1 package (solenoid valve + governor + solenoid valve) realizes compact piping in double shutoff application. CC-1104A GHV Series 3-in-1 package (solenoid valve + governor + solenoid valve) realizes compact piping in double shutoff application. Main features Space-saving integrated structure Two solenoid valves

More information

PRELIMINARY. Engine Speed Standby Power Prime Power Continuous Power. RPM kwm BHP kwm BHP kwm BHP. Litre / hour

PRELIMINARY. Engine Speed Standby Power Prime Power Continuous Power. RPM kwm BHP kwm BHP kwm BHP. Litre / hour Cummins Inc. Columbus, Indiana 47201 Engine Data Sheet Basic Engine Model: 1-G8 Engine Critical Parts List: CPL: 2816 Curve Number: FR-10302 Date: 3Oct01 1 Displacement : 1 liter (912 in 3 ) Bore : 137

More information

SO 61 to SO 126 Oil-free screw compressors (air or water cooled)

SO 61 to SO 126 Oil-free screw compressors (air or water cooled) LFL 2012-03_EN_olie-vrij_schroef_so-serie SO 61 to SO 126 Oil-free screw compressors (air or water cooled) Free air delivery: 5.25 13.01 m³/min, 185 459 cfm Pressure range: 8 10 bar, 115 150 psig Motor

More information

CHBE320 LECTURE III ACTUATOR AND CONTROL VALVE SELECTION. Professor Dae Ryook Yang

CHBE320 LECTURE III ACTUATOR AND CONTROL VALVE SELECTION. Professor Dae Ryook Yang CHBE320 LECTURE III ACTUATOR AND CONTROL VALVE SELECTION Professor Dae Ryook Yang Spring 2018 Dept. of Chemical and Biological Engineering 3-1 Visit Actuator Road Map of the Lecture III + - Controller

More information

Vacuum pump system type

Vacuum pump system type type VS*P Vacuum component C O N T E N T S Series variation 166 20 mm width universal type (/M) 168 10.5 mm width universal type (/M) 184 31.5 mm width discrete type (VSQP) 214 11 mm pitch manifold dedicated

More information

Test Which component has the highest Energy Density? A. Accumulator. B. Battery. C. Capacitor. D. Spring.

Test Which component has the highest Energy Density? A. Accumulator. B. Battery. C. Capacitor. D. Spring. Test 1 1. Which statement is True? A. Pneumatic systems are more suitable than hydraulic systems to drive powerful machines. B. Mechanical systems transfer energy for longer distances than hydraulic systems.

More information

Energy Saving: Pneumatic Systems

Energy Saving: Pneumatic Systems Energy Saving: Pneumatic Systems To earn Professional Development Hours (PDH): 1. Log into the CONEXPO CON/AGG App 2. Go to this session in Schedule 3. Check In using the Slider in Session Detail Energy

More information

V4043/V4044 Motorized Valves

V4043/V4044 Motorized Valves V4043/V4044 Motorized Valves PRODUCT SPECIFICATION SHEET FEATURES V4043 provides 2-position, straight-through control of water. V4044 provides 2-position diverting control of water. Compact construction

More information

HVB/HVL. Solenoid valve for high vacuum. For vacuum, inert gas, air, nitrogen CONTENTS. Overview

HVB/HVL. Solenoid valve for high vacuum. For vacuum, inert gas, air, nitrogen CONTENTS. Overview HV/HVL For vacuum, inert gas, air, nitrogen HN/G US/G F/G Overview dvanced technology, such as stability in the leak amount (vacuum holding force) and increased seal life, is required when the degree of

More information

ER100 Series OUT. Specifications. Working fluid Working pressure range Control pressure range. Input voltage 2 wire Input impedance.

ER100 Series OUT. Specifications. Working fluid Working pressure range Control pressure range. Input voltage 2 wire Input impedance. Electro pneumatic regulator (nozzle flapper method) ER Series Variable controlling air pressure with electric signals ( to V DC / to ma DC) up to.mpa. Booster relay integrated and large flow rate. JIS

More information

General TAHVIEH HAMOON Airfoil Centrifugal Fans Utilize the latest design techniques to product a quiet highly efficient air mover.

General TAHVIEH HAMOON Airfoil Centrifugal Fans Utilize the latest design techniques to product a quiet highly efficient air mover. General TAHVIEH HAMOON Airfoil Centrifugal Fans Utilize the latest design techniques to product a quiet highly efficient air mover. Aerodynamically designed blades and air passages allow more air to be

More information

Circuit of directional control valve and regulator. Simplifying circuit design. Space saving and piping. work eliminated. Automating pressure control

Circuit of directional control valve and regulator. Simplifying circuit design. Space saving and piping. work eliminated. Automating pressure control Port Electro-Pneumatic Proportional Valve Series 000/000 Capable of actuating a cylinder and performing analog control of pressurization alone can be used to switch and actuate a cylinder and to perform

More information

Product Specifications *

Product Specifications * 1 Up to 1.7 LPM Free Flow Typical Markets Clinical Diagnostics Analytical Chemistry Printing Typical Applications Clinical Chemistry Wash and Waste Circuits Urinalysis Liquid Chromatography Large Format

More information

CycloBlower Transport Series Dry Bulk Truck Blowers

CycloBlower Transport Series Dry Bulk Truck Blowers CycloBlower Transport Series Dry Bulk Truck Blowers 2 CycloBlower Transport Series Gardner Denver Tradition Quality Innovation Results T5CDL9L with Mounting Kit Quality + Tradition = Trust Tradition: 150

More information

SERIES Pulse and 12 Pulse DC Power Supplies for Electrocoating and Industrial DC Powered Systems MODELS 506 & 5012

SERIES Pulse and 12 Pulse DC Power Supplies for Electrocoating and Industrial DC Powered Systems MODELS 506 & 5012 100V to 1000V DC 100A to 5000A DC SERIES 50 MODELS 506 & 5012 6 Pulse and 12 Pulse DC Power Supplies for Electrocoating and Industrial DC Powered Systems Applications: Electrocoating Ion Nitriding Magnet

More information

Pressure Control Equipment

Pressure Control Equipment Control High-pressure Precision General Purpose Special Fluid/Deionized Water (Pure Water) Detection Control Control (General purpose, high-pressure, precision, vacuum, special fluid, deionized water (pure

More information

POSITIVE DISPLACEMENT BLOWERS & VACUUM PUMPS. HeliFlow Industrial Series

POSITIVE DISPLACEMENT BLOWERS & VACUUM PUMPS. HeliFlow Industrial Series POSITIVE DISPLACEMENT LOWERS & VACUUM PUMPS HeliFlow Industrial Series It's all about... the HeliFlow The HeliFlow Series integrates proven experience with blower design and manufacturing techniques to

More information

Quick Reference Charts

Quick Reference Charts Quick Reference Charts Adjustable Pressure Switches 0" to 40" H 2 O 7" H 2 O to 15 psig.5 to 1900 psig 35 to 2300 psig 2.3 to 2800 psig 14 to 10000 psig ALUM. STAIN. MONEL BUNA N STAIN. TANTLM. Compact

More information

Model and Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS. PumpAgents.com - buy pumps and parts online INDUSTRIAL DIAPHRAGM PUMPS

Model and Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS. PumpAgents.com - buy pumps and parts online INDUSTRIAL DIAPHRAGM PUMPS Model 31801 and 31800 Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS INDUSTRIAL DIAPHRAGM PUMPS FEATURES Run Dry Ability Self-Priming Thermal Overload Protected Motor Easy Installation Low Amp Draw Compact

More information

Vibration Test Systems

Vibration Test Systems Vibration Test Systems Lansmont Vibration Test Systems are versatile, easy to operate, and reliable servo-hydraulic vibration testing equipment. Whether you are testing bare products, individual packages,

More information

User s Manual. Pneumatic Positioner. Series 58. J Flow. Series 58. J Flow

User s Manual. Pneumatic Positioner. Series 58. J Flow. Series 58. J Flow Pneumatic Positioner Series 58 User s Manual J Flow Series 58 J Flow Series 58 J Flow Controls, LLC 14 De Camp Cincinnati, OH 45216 Phone: 513-731-2900 Fax 513-731-6939 www.jflowcontrols.com Introduction

More information

Function Fittings. Flow Control Regulators. Piloted Function Fittings. Non-Return Valves. LIQUIfit Pressure Fittings. Other Function Fittings

Function Fittings. Flow Control Regulators. Piloted Function Fittings. Non-Return Valves. LIQUIfit Pressure Fittings. Other Function Fittings Flow Control Regulators Piloted Non-Return Valves LIQUIfit Pressure Fittings Other Silencers Flow Control Regulators (P. 4-6) Blocking Fittings (P. 4-36) Piloted Non-Return Valves (P. 4-38) Function:

More information

VAS VAS VACUUM SWITCH SPECIFICATIONS. DIMENSIONS (mm)

VAS VAS VACUUM SWITCH SPECIFICATIONS. DIMENSIONS (mm) VACUUM SWITCHES VAS VACUUM SWITCH Diaphragm vacuum switch Compact size Lightweight Inch port sizes 5/32, 1/4 & 5/16 Metric port sizes 4, 6 & 8mm Fully adjustable VAS 10 06 Series Body Size 10 Vacuum Port

More information

OPERATOR S MANUAL AND SALES AND ENGINEERING DATA

OPERATOR S MANUAL AND SALES AND ENGINEERING DATA OPERATOR S MANUAL AND SALES AND ENGINEERING DATA INCLUDING: SPECIFICATIONS, SERVICE KITS, GENERAL INFORMATION, PARTS, TROUBLESHOOTING. INCLUDE MANUALS: AF044X-XX Air Motor (pn 97999-1466) & S-632 General

More information

H.S. MACHINERY RING COMPRESSORS

H.S. MACHINERY RING COMPRESSORS OPERATION & PARTS MANUAL Thank you for purchasing an H.S Machinery Limited Regenerative Blower. This product is manufactured under strict ISO-9001-2000 quality control guidelines to ensure your satisfaction.

More information

AGRE Industrial Piston Compressors

AGRE Industrial Piston Compressors AGRE Industrial Piston Compressors 1 AGRE INDUSTRIAL PISTON COMPRESSORS Trusted air supply for industrial applications Metal industry Paint finishing systems, pneumatic tools, and automatic work-holding

More information

Oil-injected. Installed motor power kw/ hp Free air delivery from 0.47 to m³/min, Pressure 3-40 bar CONTENTS

Oil-injected. Installed motor power kw/ hp Free air delivery from 0.47 to m³/min, Pressure 3-40 bar CONTENTS Oil-injected Rotary Screw Air Compressors Installed motor power 5.5-400 kw/7.5-550 hp Free air delivery from 0.47 to 74.20 m³/min, Pressure 3-40 bar CONTENTS 01 OIL-INJECTED ROTARY SCREW AIR COMPRESSOR

More information

Construction diagram Semiconductor transducer Silicone oil. Stainless steel SUS316 pressure port Hastelloy C diaphragm.

Construction diagram Semiconductor transducer Silicone oil. Stainless steel SUS316 pressure port Hastelloy C diaphragm. SERIES LED Display Anti-corrosive Digital ure Sensor DP3 ure Measurement of Corrosive Gases and Liquids Possible! Marked Conforming to EMC Directive Superior Anti-corrosive Hastelloy C Diaphragm and Stainless

More information

Screw Compressors DSD SERIES. Capacities from: 424 to 1024 cfm Pressures from: 80 to 217 psig

Screw Compressors DSD SERIES. Capacities from: 424 to 1024 cfm Pressures from: 80 to 217 psig Screw Compressors DSD SERIES Capacities from: 424 to 1024 cfm Pressures from: 80 to 217 psig Built for a lifetime Maximum efficiency and reliability have long been synonymous with Kaeser Compressors. Our

More information

Contents. Pressure measurement technology Pressure calibrators 18 Exercises 19-20

Contents. Pressure measurement technology Pressure calibrators 18 Exercises 19-20 1 Pressure Contents Topics: Slide No: Pressure measurement technology 03-17 Pressure calibrators 18 Exercises 19-20 2 Pressure Gauges Barometer Used to measure Barometric Pressure Reference is 0 psia,

More information

ProVent MANN+HUMMEL Oil Separator for Closed and Open Crankcase Ventilation

ProVent MANN+HUMMEL Oil Separator for Closed and Open Crankcase Ventilation ProVent MANN+HUMMEL Oil Separator for Closed and Open Crankcase Ventilation ProVent high performance with distinct advantages ProVent is MANN+HUMMEL's newest innovation for crankcase ventilation. It is

More information

SINGLE STAGE TWO STAGES

SINGLE STAGE TWO STAGES BLOWERS CATALOG Table of contents SINGLE STAGE TWO STAGES 3 4 1 1 5 6 7 8 9 10 11 12 Weight (Kg) 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 2RSC 50-65 Performance curve for Vacuum

More information

MANN+HUMMEL ProVent. Oil separator for closed and open crankcase ventilation

MANN+HUMMEL ProVent. Oil separator for closed and open crankcase ventilation MANN+HUMMEL ProVent Oil separator for closed and open crankcase ventilation ProVent high performance with distinct advantages The development of the whole MANN+HUMMEL ProVent product family was directed

More information

Models & Options Lubrication. 1/2 Through 10 Hp Models 1Ø 3Ø 1/2 Through 10 Hp Models 1Ø and 3Ø

Models & Options Lubrication. 1/2 Through 10 Hp Models 1Ø 3Ø 1/2 Through 10 Hp Models 1Ø and 3Ø P U R E A I R T E C H N O L O G Y Climate Control Duplex Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect

More information

50H Z VERSION. WindJet Air Knife Packages. Deliver superior blowing and drying performance in a complete, customizable package.

50H Z VERSION. WindJet Air Knife Packages. Deliver superior blowing and drying performance in a complete, customizable package. 5H Z VERSION Experts in Spray Technology Spray Nozzles Spray Control Spray Analysis Spray Fabrication WindJet Air Knife Packages Deliver superior blowing and drying performance in a complete, customizable

More information

Water Treatment Plant Maintenance Considerations. Operation and Maintenance. Types of Maintenance 5/1/15

Water Treatment Plant Maintenance Considerations. Operation and Maintenance. Types of Maintenance 5/1/15 Water Treatment Plant Maintenance 1 Operation and Maintenance Purpose of O&M maintain design functionality (capacity) restore the system components to their original condition and thus functionality. Effective

More information

2-Color Display High-Precision Digital Pressure Switch

2-Color Display High-Precision Digital Pressure Switch 2-Color Display High-Precision Digital Pressure Switch Settings can be copied to up to 1 slave sensors at once. The settings of the master sensor can be copied to the slave sensors. Reduced setting efforts

More information

original operating manual Operating manual Translation of the Item-No.: ,

original operating manual Operating manual Translation of the Item-No.: , Translation of the original operating manual Operating manual Item-No.: 015 431 551, 015 431 581 Important! Copyright The operating manual is always to be read before commissioning the equipment. No warranty

More information

Product Information Stepper Motor-driven Diaphragm Dosing Pump MEMDOS SMART LP

Product Information Stepper Motor-driven Diaphragm Dosing Pump MEMDOS SMART LP Product Information Stepper Motor-driven Diaphragm Dosing Pump Reliable dosing of chemicals Stepper motor driven diaphragm pumps are particularly suitable for highly accurate, reproducible industrial dosing

More information

PRECISION UK Ltd DUPLEX AGSS PLANT

PRECISION UK Ltd DUPLEX AGSS PLANT DUPLEX AGSS PLANT Contents Page Section Page Product Description General 3 AGSS Plant 3 AGSS Remote Switch 3 Operation General 4 Safety General 5 Installation General 5 Mechanical 5 Electrical 7 Wiring

More information

BLOWERS EXHAUSTERS. Positive Displacement blowers (PD), as the name implies, compress CONTINENTAL INDUSTRIE

BLOWERS EXHAUSTERS. Positive Displacement blowers (PD), as the name implies, compress CONTINENTAL INDUSTRIE COMPARISON Blowers Exhausters Page 1 of 6 Technical comparison... P 4 Positive Displacement blowers (PD), as the name implies, compress an incremental volume of gas between the inlet and outlet of the

More information

Improving Lives through Innovation TM. Global Catalog. Compressors, Vacuum Pumps & Liquid Pumps

Improving Lives through Innovation TM. Global Catalog. Compressors, Vacuum Pumps & Liquid Pumps Improving Lives through Innovation TM Global Catalog Compressors, Vacuum Pumps & Liquid Pumps Pumps and Compressor Solutions for OEMs Worldwide As a leader in providing fluidic solutions to Original Equipment

More information

Positive Displacement Pump

Positive Displacement Pump www.conairgroup.com U S E R G U I D E UGC028-1105 Positive Displacement Pump Models PD 3. 5, 7.5, 10, 15 and 25 Corporate Office: 724.584.5500 l Instant Access 24/7 (Parts and Service): 800.458.1960 l

More information

MICROPUMP MAG-DRIVE GEAR PUMPS

MICROPUMP MAG-DRIVE GEAR PUMPS MAG-DRIVE GEAR PUMPS REVISION # 1 DATE: 6-6-6 WETTED MATERIALS Pump housings: 316 stainless steel. Gears: PEEK. Gear shafts: 316 stainless steel. Gear shaft bearings: PEEK. Driven magnet: Totally encapsulated

More information

Engine Performance 1500 RPM

Engine Performance 1500 RPM CUMMINS ENGINE COMPANY, INC Columbus, Indiana 471 ENGINE PERFORMANCE CURVE Basic Engine Model: QST-G3 Engine Critical Parts List: CPL: 284 Curve Number: FR-188 Date: 23Dec3 Q 1 Displacement :.48 liter

More information

MODEL PERFORMANCE. ENGINE MOUNTING Maximum Bending Moment at Rear Face of Block... lb ft (N m) 1000 (1356)

MODEL PERFORMANCE. ENGINE MOUNTING Maximum Bending Moment at Rear Face of Block... lb ft (N m) 1000 (1356) CPL INSTALLATION DIAGRAM Engine: Engine With Radiator : GENERAL DATA Type... 4 Cycle; In-line; 6 Cylinder Diesel Aspiration... Turbocharged and Air to Air Aftercooled Bore x Stroke... in x in (mm x mm)

More information

ITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa

ITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa 5.0 MPa Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator X Series This product is only for blowing gas. This product does not have sufficient pressure control for other applications (driving,

More information

VE-S_15-32 Pressure Independent Balancing & Control Valves

VE-S_15-32 Pressure Independent Balancing & Control Valves Page 1 of 9 VE-S_15-32 Pressure Independent Balancing & Control Valves (PIBCV) is used in heating and cooling systems in applications with Fan Coil Units, Chilled Beams or other terminal unit applications.

More information

PNEUMATICALLY ACTUATED 2-WAY

PNEUMATICALLY ACTUATED 2-WAY 482 DN 25-65 The 482 diaphragm valve is particularly suitable for shutting off and regulating abrasive or dirty fluids. The new internal geometry of the body optimises fluid dynamic efficiency by increasing

More information

Pneutronics. Miniature Proportional Valves. Catalog PND-MPV-001/US January 2007

Pneutronics. Miniature Proportional Valves. Catalog PND-MPV-001/US January 2007 Pneutronics Miniature Proportional Valves January 2007 Non-Thermally Compensated Proportional Valve HF 200 Miniature Ultra High Flow Proportional Valve HF 200 is a high flow proportional valve that provides

More information

ALD3 Diaphragm Valve Technical Report

ALD3 Diaphragm Valve Technical Report ALD Diaphragm Valve Technical Report Scope This technical report provides data on Swagelok ALD normally closed diaphragm valves. The report covers: helium seat leak testing valve flow consistency analysis

More information

IST INTELLIGENT SUBMERSIBLE TURBINE

IST INTELLIGENT SUBMERSIBLE TURBINE INTELLIGENT SUBMERSIBLE TURBINE IST The FIRST Submersible Pump Ever Designed For High Volume Retailers. The NEW 4HP 4" Diameter Variable Speed Turbine. When FAST Fueling Means MORE Sales. THE IST... NOW

More information

SULLAIR Oil Free Rotary Screw Air Compressors

SULLAIR Oil Free Rotary Screw Air Compressors SULLAIR Oil Free Rotary Screw Air Compressors 100 350 hp 75 261 kw sullair an industry leader Leadership Since 1965, Sullair has been recognized worldwide as an innovator and leader in rotary screw compression

More information

60 Hz FEATURES. Exclusively from your Caterpillar dealer

60 Hz FEATURES. Exclusively from your Caterpillar dealer D I E S E L G E N E R A T O R S E T S STANDBY PRIME 60 Hz 60-100 kw 54-90 kw Model Standby Prime kw (kva) kw (kva) D60P4S* 60 (60) 54 (54) D75P3 75 (93.8) 68 (85) D80P4* 80 (100) 72 (90) D75P1S 75 (75)

More information

Operating Instructions Vaccon VDS-1000 Solid State Combination Vacuum Switch/Sensor w/ Digital Display

Operating Instructions Vaccon VDS-1000 Solid State Combination Vacuum Switch/Sensor w/ Digital Display Operating Instructions Vaccon VDS-1000 Solid State Combination Vacuum Switch/Sensor w/ Digital Display Installation The VDS-1000 combines either two (2) low voltage, high side or low side, switched outputs

More information

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry Series 0-VQ00 port solenoid valve How to Order Valves 0 VQ 0 F ir cylinder Clean series Series VQ Compact port valve Type of actuation Normally closed Note) Normally open Note) Normally open type is available

More information

PNEUMATIC CONTROL SYSTEMS DESIGN AND CONSTRUCTION STANDARD PART 1 - GENERAL. A. Codes and Standards that are Standard at the University:

PNEUMATIC CONTROL SYSTEMS DESIGN AND CONSTRUCTION STANDARD PART 1 - GENERAL. A. Codes and Standards that are Standard at the University: PART 1 - GENERAL 1.01 Purpose: A. This design guideline contained here in includes the requirements for pneumatic control systems at The University of Texas at Austin. It is the intent to provide the highest

More information

CycloBlower Industrial Series. Positive Displacement Blowers & Vacuum Pumps

CycloBlower Industrial Series. Positive Displacement Blowers & Vacuum Pumps CycloBlower Industrial Series Positive Displacement Blowers & Vacuum Pumps 2 50 Years of Proven Results The Gardner Denver CycloBlower Industrial Series offers significant advantages: Efficiency Quality

More information

DP5/DPH. Head Separated Digital Pressure Sensor. 1/1000 Second High-Speed Response. The advantage of the fastest response in the industry SERIES

DP5/DPH. Head Separated Digital Pressure Sensor. 1/1000 Second High-Speed Response. The advantage of the fastest response in the industry SERIES Head Separated Digital Pressure Sensor SERIES /000 Second High-Speed Response Conforming to EMC Directive UL Recognition /,000 sec. The advantage of the fastest response in the industry 55 High speed in

More information

Body width of 10mm, Nl/min (49.08) 2W (Standard) Nl/min (78.52) 4W (U type: Large flow) Vacuum applications possible (up to 100kPa) 3 S.

Body width of 10mm, Nl/min (49.08) 2W (Standard) Nl/min (78.52) 4W (U type: Large flow) Vacuum applications possible (up to 100kPa) 3 S. High speed coil with stable response times ON: 4ms, OFF: 2ms, Dispersion accuracy: ±1ms (With light and surge voltage suppressor at a supply pressure of 0.5MPa, subject to clean, dry air) 4 Port Direct

More information

HeliFlow Industrial Series. Positive Displacement Blowers & Vacuum Pumps

HeliFlow Industrial Series. Positive Displacement Blowers & Vacuum Pumps HeliFlow Industrial Series Positive Displacement lowers & Vacuum Pumps 2 GD HeliFlow uilt y the Industry Leaders GD HeliFlow HeliFlow integrates proven experience with blower design and manufacturing techniques

More information

Simple Set COMMERCIAL. Pressure Independent Control Valves 2 Way 1/2-2 02/16/18 COMMERCIAL

Simple Set COMMERCIAL. Pressure Independent Control Valves 2 Way 1/2-2 02/16/18 COMMERCIAL The Bray Simple Set is a threaded pressure independent control (PIC) valve designed for a wide variety of hot water and chilled water control applications. The SS Series combines high rangeability control

More information

Swing Piston Compressors and Vacuum Pumps

Swing Piston Compressors and Vacuum Pumps Swing Piston Compressors and Vacuum Pumps NPK 018 AC Pressure NPK 018 DC Pressure NPK 018 AC Vacuum NPK 018 DC Vacuum Operating and Installation Instructions Read and observe these Operating and Installation

More information

KTA50 Land Based Drilling Power Modules

KTA50 Land Based Drilling Power Modules KTA50 Land Based Drilling Power Modules Description Cummins Land Based Drilling Power Modules are designed and tested based on oil field customer requirements to provide optimum performance, reliability,

More information

Electro-Pneumatic Regulators. Electronic Vacuum Regulators

Electro-Pneumatic Regulators. Electronic Vacuum Regulators Electro-Pneumatic Regulator Electronic Vacuum Regulator New Reduced wiring Applicable Fieldbus protocols Compact & light Weight: g Note ) (ITV) Power consumption: 4 W Note ) or less Electro-Pneumatic Regulators

More information

ISO Certificate N 12-E TIC. ISO 9001 Certificate N 12-Q TIC

ISO Certificate N 12-E TIC. ISO 9001 Certificate N 12-Q TIC HYDRAULIC COMPONENTS HYDROSTATIC TRANSMISSIONS GEARBOXES - ACCESSORIES Certified Company ISO 9001-14001 ISO 9001 Certificate N 12-Q-0200545-TIC ISO 14001 Certificate N 12-E-0200545-TIC Via M. L. King,

More information

Cylindrical Pumps. J-Series Cylindrical Venturi Pumps

Cylindrical Pumps. J-Series Cylindrical Venturi Pumps J-Series Cylindrical Venturi Pumps The J-Series Venturi Vacuum Pumps utilize a fixed cartridge venturi design. J-Series pumps employ a cylindrical design for ease of installation and mounting into in-line

More information

Powers TM Controls Three-way Electro-pneumatic (EP) Valve Model 2

Powers TM Controls Three-way Electro-pneumatic (EP) Valve Model 2 Powers TM Controls Three-way Electro-pneumatic (EP) Valve Model 2 Document No. 155-078P25 VE 265-2 Description The VE 265 Electro-Pneumatic Valve is a general purpose, electrically operated, twoposition

More information

Vacuum applications possible (up to 100kPa) Base mounted. Cylinder bore size (mm) Series CM2. Pressure: 0.5MPa Load ratio: 50% Cylinder stroke: 300mm

Vacuum applications possible (up to 100kPa) Base mounted. Cylinder bore size (mm) Series CM2. Pressure: 0.5MPa Load ratio: 50% Cylinder stroke: 300mm 4 Port Direct Operated Poppet Solenoid Valve Series D1000 High speed coil with stable response times ON: 4ms, OFF: 2ms, Dispersion accuracy: ±1ms (With light and surge voltage suppressor at a supply pressure

More information

25% reduction in volume * PB1013A/Air-operated type without foot

25% reduction in volume * PB1013A/Air-operated type without foot Process Pump (Diaphragm Pump) Series Compact, large capacity diaphragm pump, suitable for transferring and collecting a wide range of fluids Smaller, lighter, lmtop size Pa 5% reduction in volume * 11A/Air-operated

More information

KSI Filtertechnik GmbH Siemensring D Willich Tel Fax

KSI Filtertechnik GmbH Siemensring D Willich Tel Fax BA SIC.LINE Rev 1.0.1 Page 1 of 9 KSI Filtertechnik GmbH Siemensring 54-56 D-47877 Willich Tel. +49 21 54 89 108-0 Fax +49 21 54 89108-282 www.ksi.eu mail@ksi.eu ECOCLEAN Compressed air filters new generation

More information

A system of lubricant dispensing devices (oil or grease) connected by piping to a central pumping unit that is operated automatically or manually.

A system of lubricant dispensing devices (oil or grease) connected by piping to a central pumping unit that is operated automatically or manually. Air/Oil Systems: A lubrication system in which small measured quantities of oil are introduced into an air/oil mixing device which is connected to a lube line that terminates at a bearing, or other lubrication

More information

TPV Variable Displacement Axial Piston Pumps CONTENTS. General Information. Installation Instructions. Technical Specifications 6-7

TPV Variable Displacement Axial Piston Pumps CONTENTS. General Information. Installation Instructions. Technical Specifications 6-7 CONTENTS General Information Installation Instructions Technical Specifications Single Pump Installation Drawing Tandem Pump Installation Drawing Mounting Flanges and Shaft Details Rear Pump Mounting Flanges

More information

NOVAPLEX Integral. Process Diaphragm Pumps. motralec

NOVAPLEX Integral. Process Diaphragm Pumps. motralec motralec 4 rue Lavoisier. ZA Lavoisier. 95223 HERBLAY CEDEX Tel. : 01.39.97.65.10 / Fax. : 01.39.97.68.48 Demande de prix / e-mail : service-commercial@motralec.com www.motralec.com NOVAPLEX Integral Process

More information

Pneumatic Division North America Richland, MI 49083

Pneumatic Division North America Richland, MI 49083 Pneumatic Division North America Richland, MI 08 Installation Instructions: V-0P /8" Valvair II/A Series Valves Single Operated ISSUED: May, 00 Supersedes: November, 8 ECN #6 Rev. 6 WARNING To avoid unpredictable

More information

See Note. 100% of rated load

See Note. 100% of rated load Generator set data sheet 2000 kw Continuous Model: C2000 N6C Frequency: 60 Hz Fuel type: Natural gas MI 76 + Emissions NOx: 0.5 g/hp-h LT water inlet temp: 50 C (122 F) HT water outlet temp: 92 C (198

More information

Warning and Safety Precautions

Warning and Safety Precautions EXPRESS WARRANTY AND DISCLAIMER OF IMPLIED WARRANTIES Lily Corporation unconditionally guarantees its products to be free of defects in material or workmanship and further warrants that, for a period of

More information

Becker Precision Equipment

Becker Precision Equipment Becker Precision Equipment HPP-SB Series Pneumatic Valve Positioner HPP-SB Pneumatic Positioners Provide Accurate Positioning of Single-Acting Actuated Control Valves Description The Becker Model HPP-SB

More information

VIKING HG SERIES HELICAL GEAR EXTERNAL GEAR PUMPS

VIKING HG SERIES HELICAL GEAR EXTERNAL GEAR PUMPS Page 350.1 Series Description Viking s HG series positive displacement pumps are designed to provide low noise transfer and processing of clean, lubricating liquids for applications such as lube oils,

More information

See Note. 100% of rated load

See Note. 100% of rated load Generator set data sheet 2000 kw Continuous Model: Frequency: Fuel type: Emissions NOx: LT water inlet temp: HT water outlet temp: C2000 N6C 60 Hz Low BTU 0.5 g/hp-h 50 C (122 F) 92 C (198 F) Measured

More information

HYDRAULIC VARIABLE PUMPS

HYDRAULIC VARIABLE PUMPS HYDRAULIC VARIABLE S EFFICIENT VARIABLE DELIVERY Checkball pump delivery is controlled by variable inlet ports in each piston pumping chamber. In these hydraulic variable models, output is regulated by

More information

Zone Valves and Parts (Honeywell)

Zone Valves and Parts (Honeywell) 28/11/14 B49 Zone Valves - Two Way Fan Coil Zone Valves and Parts (Honeywell) Two-way Fan Coil Valve, the VU53 high pressure zone valves are used to control the flow of hot or chilled water in commercial

More information

See Note. 100% of rated load 2,4,6, (17.73)

See Note. 100% of rated load 2,4,6, (17.73) Generator set data sheet 2000 kw Continuous Model: Frequency: C2000 N5CB 50 Hz Fuel type: Natural gas MI 70 + Emissions NOx: 350 mg/nm 3 LT water inlet temp: HT water outlet temp: 40 C (104 F) 92 C (198

More information

DPS280 / DVS280 Series

DPS280 / DVS280 Series 1 2 3 4 5 6 7 8 Do not use corrosive or flammable gases or liquid with this product. Please use within the rated pressure range. Do not apply pressure beyond recommended maximum pressure, permanent damage

More information

Ultra-Matic Air Valve System

Ultra-Matic Air Valve System Ultra-Matic Air Valve System Efficient Pumps, Competitive Upgrades and Accessories U2 Plastic Pumps Metallic Pumps Specialty Pumps Upgrade Kits Accessories Diaphragms Ultra-Matic Air Valve Technology Simple.

More information

DESCRIPTION 9.4 G 3/4"M

DESCRIPTION 9.4 G 3/4M DESCRIPTION Six-way ballvalve for HVAC 4 pipes applications to automatically carry out the winter-summer change-over or, potentially, to manage radiant ceilings, fan coils and chilled beams. DIMENSIONS

More information

Normally Open Miniature Proportional Valve Thermally Compensated Proportional Valve

Normally Open Miniature Proportional Valve Thermally Compensated Proportional Valve Lone Wolf Typical Applications Blood Pressure Monitoring Vitreo Retinal Surgery Normally Open Miniature Proportional Valve Thermally Compensated Proportional Valve The Lone Wolf miniature proportional

More information

ABOUT MATTEI CUSTOM BUILT MATTEI COMPRESSOR PACKAGES

ABOUT MATTEI CUSTOM BUILT MATTEI COMPRESSOR PACKAGES ABOUT MATTEI Applied Compression is proud to be a distributor of Mattei rotary vane air compressors. Founded in 1919, Mattei is the world s leading manufacturer of rotary vane air compressors. Mattei compressors

More information

PRODUCT RELEASE CKMTA12 / 24

PRODUCT RELEASE CKMTA12 / 24 PRODUCT RELEASE CKMTA12 / 24 ARB CKMTA12 / 24 MAXIMUM PERFORMANCE ON-BOARD AIR SUPPLY Brief Description: ARB's new CKMTA12 and CKMTA24 twin on-board compressor kits were designed to fill the market need

More information

AutoJet Lubrication Systems

AutoJet Lubrication Systems AutoJet Lubrication Systems AutoJet Lubrication Systems AutoJet Lubrication Systems provide a highly efficient method of applying lubricants and corrosion protection fluids. In addition to lubricating

More information

G50U MODEL STANDARD FEATURES GENERATOR RATINGS CONDITIONS OF SALE. General features :

G50U MODEL STANDARD FEATURES GENERATOR RATINGS CONDITIONS OF SALE. General features : G50U MODEL Stand-by Power @ 60Hz Prime Power @ 60Hz G50U 45-55 kw /48-69 kva 44-50 kw / 44-63 kva GAS GENSET STANDARD FEATURES General features : SDMO Industries provides one-source responsibility for

More information

Completing Your Fume Removal System

Completing Your Fume Removal System Once a laboratory hood has been selected, the next step is to select the proper blower and ductwork. It is important that these be sized correctly depending on hood size, application, CFM, and distance

More information

V Series AXIAL PISTON PUMP ORDER CODE

V Series AXIAL PISTON PUMP ORDER CODE V Series AXIAL PISTON PUMP ORDER CODE V 15 A 1 R B S - A 1 D X A 11 Customers demand Pump Series V Links Type (only V 15-18): none - Standard A - SAE A 2 bolts Ma. Displacement (cm 3 /n): 15, 18, 23, 25,

More information

Electro-Pneumatic Regulators. Electronic Vacuum Regulators

Electro-Pneumatic Regulators. Electronic Vacuum Regulators Electro-Pneumatic Regulator Electronic Vacuum Regulator Stepless control of air pressure proportional to an electrical signal Added Fieldbus compliant specifications to New Series Reduced wiring Series

More information

10 switches simultaneously. The settings of the master sensor (source of copy) can be copied to the slave sensors. Reducing setting labor

10 switches simultaneously. The settings of the master sensor (source of copy) can be copied to the slave sensors. Reducing setting labor 2-Color Display High-Precision Digital Pressure Switch ZSE ISE RoHS ZSE ISE IP65 ZSE40 ISE40 M8 connector type ZSE10 ISE10 ISE70 ZSE80 ISE80 PS ISA3 ISA2 ISE35 Applicable Air, Non-corrosive gas, Non-flammable

More information

Electro-Pneumatic Regulator Electronic Vacuum Regulator

Electro-Pneumatic Regulator Electronic Vacuum Regulator Electro-Pneumatic Regulator Electronic Vacuum Regulator New Stepless control of air pressure proportional to an electrical signal Added Fieldbus compliant specifications to Series ITV//! Reduced wiring

More information

Eurovacuum Installations and Operating manual EVD Series Vacuum pumps Models: EVD-6 to EVD-90. Double Stage Oil Lubricated Rotary Vane Vacuum Pump

Eurovacuum Installations and Operating manual EVD Series Vacuum pumps Models: EVD-6 to EVD-90. Double Stage Oil Lubricated Rotary Vane Vacuum Pump Eurovacuum Installations and Operating manual EVD Series Vacuum pumps Models: EVD-6 to EVD-90 Double Stage Oil Lubricated Rotary Vane Vacuum Pump Eurovacuum EVD-Series Double Stage Oil Sealed Rotary Vane

More information