Infrastructure requirements
|
|
- Samantha Anthony
- 6 years ago
- Views:
Transcription
1 Infrastructure requirements
2 Infrastructure Requirements for TechPod TM Installation: NOTE: The following infrastructure requirements are only manufacturer's recommendations and serve as such. All requirements should be performed by professional and certified personnel for installation of electricity circuits and AV equipment. Fixed Installation: All described wires will be concentrated/gathered beneath the TechPod TM location on stage/floor in an AV floor box (could be located inside the stage with easy access to the different wires and connectors) (hereinafter "AV floor box"). Moveable Installation: Using Extension Cables & 2 Wheels (Product code: TCB-33), a Wall Box is needed instead of AV Floor box. A. Projector/Beamer connections and cables: 1. VGA Quality VGA cable Recommended cable type quality long distance VGA Projector end male 15 pin VGA connection TechPod TM end male 15 pin VGA connection 2. Control 2 conductors cable Recommended cable type 2X22 PVC insulated and jacketed unshielded LF control cable Projector end female MINI (3.5 mm audio) MONO connector TechPod TM end male MINI (3.5 mm audio) MONO connector B. Ethernet / Network connection: Ethernet / Network connection 10/100/1000MB Ethernet connection RJ45 socket connection. Note: The Ethernet connection will allow TechPod TM computer access to the organization network, files and internet access through the existing network. Recommended 2 RJ45 sockets (2 Ethernet lines) for future connections or additional laptop Ethernet connection.
3 C. Speakers: Cables for Speakers - Recommended cable type - Quality 2X0.5mm 100V PA speaker cable TechPod TM end MALE XLR (5 Pin) plug on cable. Should arrive at the AV floor box and will go to each location of a speaker (dependant on the amount of speakers to be installed maximum 6 speakers per classroom could be installed). D. Electricity requirements: V socket 13A direct line (minimum 5A) from electricity main circuit board. Note: The TechPod TM socket should be clearly marked for it's connection board and where it could be switched off. If possible the projector/beamer electricity socket should be fed from the same phase/circuit as TechPod TM. 2. Grounding/earth point - 14AWG minimum standard copper wire.
4 Optional components: A. Motorized Electric Screen control: The motorized electric screen control will allow automatic UP/Down control from TechPod TM control panel (will automatically lower the screen when "Projector ON" button is pressed and will automatically raise the screen when "Projector OFF" button is pressed or when the side door is closed). Requirements: All electricity for the motorized electric screen should be gathered to a surface mount/in wall enclosure for 35mm DIN RAIL mounted type electricity enclosure (size to fit 4 EN modules) (recommended type GEWISS GW40001 or equivalent). This enclosure should be located near the motorized screen. 1. Line feed 110V (+, -, and ground) 2. Screen UP/DOWN wall switch (included with the motorized screen) MUST be "momentary switch". 3. Space for the above mentioned enclosure 4. Link to the AV floor box (TechPod TM ) 12V low voltage control at least 16mm pipe. For Motorized Curtains same operation and requirements apply for each curtain circuit. See drawings attached on next page.
5 Schematic Drawing: 110V (+, -, Ground) TechPod 12VDC control Motorized Electric Screen control enclosure to fit 4 EN modules UP/ Down wall Motorized screen Functional drawing: Motorized Screen Motorized Electric Screen control enclosure 16mm Pipe UP/ Down wall switch TechPod Floor Box Notes: All electricity changes and modification are to be done by certified electricity engineer. Electric drawings of the system will be served upon request.
6 B. Lights control: The lights control, through TechPod TM control panel, is divided into 3 zones (back, front and dimmer). 1. TechPod TM lights control will only provide low-voltage control (12V DC). High voltage connections are to be performed and connected to TechPod TM by a qualified and certified electricity engineer. 2. In order to control house lights, each of the above mentioned circuits is required to be operated by a "STEP Relay / Switch" (i.e. first press to "Lights ON" mode, second press to "Lights OFF" mode). 3. From each wall switch in the hall (3 zones), 2 parallel lines need to be drawn to a separate electricity enclosure (surface mount / in wall enclosure for 35mm DIN RAIL mounted type electricity enclosure (size to fit 8 EN modules)) (recommended GEWISS GW40003 or equivalent). 4. Recommendation - this enclosure is to be located at above average operating height (for safety reasons). 5. There should be a 16mm pipe link between this enclosure and the TechPod TM floor box (for 4X22 PVC insulated and jacketed unshielded LF control cable). Note: All electricity changes and modification are to be done by electricity certified engineer. Electronic drawings of the system will be served upon request. See drawings attached on next page.
7 Schematic Drawing: Front Light Back Light Electronic Dimmer Wall switch Wall switch Wall switch TechPod TM TechPod TM Light control enclosure Space for 8 EN Modules Functional diagram: Back Front Dimm Front Back Dimm TechPod TM Light control enclosure 16mm Pipe TechPod TM Floor Box
Cart Power. Power Distribution System. Operation Manual Version 1.0 Copyright 2003 Professional Sound Corporation Printed in the U.S.A.
Cart Power Power Distribution System Operation Manual Version 1.0 Copyright 2003 Professional Sound Corporation Printed in the U.S.A. Thank you for purchasing the Professional Sound Corporation Cart Power
More informationSAVE THESE INSTRUCTIONS
Dimmer Power Module - through 5 READ AND FOLLOW ALL SAFETY INSTRUCTIS! SAVE THESE INSTRUCTIS AND DELIVER TO OWNER AFTER INSTALLATI IMPORTANT SAFETY INSTRUCTIS! WARNING To reduce the risk of death, injury
More informationSAVE THESE INSTRUCTIONS
READ AND FOLLOW ALL SAFETY INSTRUCTIS! SAVE THESE INSTRUCTIS AND DELIVER TO OWNER AFTER INSTALLATI IMPORTANT SAFETY INSTRUCTIS! WARNING To reduce the risk of death, injury or property damage from fire,
More informationEPIC CIRCON M23 Series
M23 Series EPIC EPIC CIRCON M23 Series Application Advantage Rugged nickel-plated, die-cast zinc body Positive vibration protection for use with motor drives and moving assemblies Integral EMC cable gland
More informationSpecifications PLS 201D, PLS 211D, PLS 401D, and PLS 411D Digital Systems
Specifications PLS 201D, PLS 211D, PLS 401D, and PLS 411D Digital Systems specification HDMI inputs 1 to 6 Max. 4K Capabilities Resolution and Refresh Rate 4096 x 2160 at 30 Hz 3840 x 2160 at 30 Hz 4096
More informationPD404-AN V analog control 4 Channel x 500 W Dimmer & Switch Packs ANALOG 0-10 V. Serial Number
0-10V analog control 4 Channel x 500 W Dimmer & Switch Packs ANALOG 0-10 V 4 circuit Analog 1-10V 4 x 4 A. Dimmer pack Serial Number Dimmers Indicators Digital Lighting Systems,Inc Info@digitallighting.com
More informationSAVE THESE INSTRUCTIONS
READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be
More informationSAVE THESE INSTRUCTIONS
READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION IMPORTANT SAFEGUARDS! When using electrical equipment, basic safety precautions should always be
More informationANZI Transfer Switch and Generator Wiring Installation Addendum
ANZI Transfer Switch and Generator Wiring Installation Addendum Reference all appropriate documentation. NOT INTENDED FOR USE IN CRITICAL LIFE SUPPORT APPLICATIONS. THIS PRODUCT CAN BE INSTALLED BY THE
More informationSpecifications PLS 201D, PLS 211D, PLS 401D, and PLS 411D Digital Systems
Specifications PLS 201D, PLS 211D, PLS 401D, and PLS 411D Digital Systems specification HDMI inputs 5 and 6 only Max. 4K Capabilities Resolution and Refresh Rate 4096 x 2160 at 30 Hz 3840 x 2160 at 30
More informationApplication Specification Circular Plastic Connector (CPC) Series 45 System 05 AUG 14 Rev D
Application Specification Circular Plastic Connector (CPC) 114-13137 Series 45 System 05 AUG 14 Rev D NOTE i All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions
More informationTechnical Data Sheet Unshielded (YY) PVC Control Cable
Technical Data Sheet Unshielded (YY) PVC Control Cable MachFlex 350 YY VDE Registered Flexible PVC Control Cables Applications Designed for applications which are installed in occasional flexing and fixed
More informationSpecifications PLS 200D, PLS 210D, PLS 400D, and PLS 410D Digital Systems
Specifications PLS 200D, PLS 210D, PLS 400D, and PLS 410D Digital Systems Overall system STP transmission... Up to 150' (46 m) Standard included cable length is 35' (11 m) Shipping weight PLS 200D System...
More informationData sheet Patch cord Cat.6 A AWG m black
Illustrations Dimensional drawing Page 1/6 See enlarged drawings at the end of document Product specification especially suitable for shielded and unshielded class E A systems fully shielded Cat.6 A patch
More informationProduct Information Page
CONVERTING OLD A-SERIES PART NUMBERS TO THE NEW A-SERIES PART NUMBERS PIP #: SW-PI-77 Applicable to: With the release of the New A-series product family, Ashcroft has A-Series discontinued the old A-series
More informationSAVE THESE INSTRUCTIONS
READ AND FOLLOW ALL SAFETY INSTRUCTIS! SAVE THESE INSTRUCTIS AND DELIVER TO OWNER AFTER INSTALLATI IMPORTANT SAFEGUARDS! When using electrical equipment, basic safety precautions should always be followed
More informationAdvantages. Options VHS06
Flow switches for insertion installation Threaded adapter with trimmable paddle Type VHS06 Type VK306 Technical data VHS06 VK306 Switching function Contact closes at increasing flow opens at decreasing
More informationAurora Universal Protocol Converter (UPC) Zone Sensors. Submittal Data English Language/IP Units SD1582EW 06/18
Zone Sensors Submittal Data English Language/IP Units SD1582EW 06/18 ZS Series RNet Zone Sensors ZS Series RNet Sensor Overview The ZS Series line of intelligent zone sensors provides the function and
More informationMDual Power Connector
MDual Power Connector Overview Utilizing the efficient high-current design of the PowerBud contact technology, the MDual power connectors carry high power in a small package and features self-aligning
More informationHan-Power Energy Bus Components
HARTING Electric Han-Power Energy Bus Components People Power Partnership Han Data Sheet 0080-7 Han-Power T Han-Power T Part-Number Drawing Dimensions in mm 09 12 008 4701 Cable gland please order separately
More informationChange the and later A/C & Heat system on the Discovery coach With the multi-zone coleman mach thermostat
Change the 2001.5 and later A/C & Heat system on the Discovery coach With the multi-zone coleman mach thermostat This schematic and wiring diagram is to be used only for single stage heating and single
More informationAurora Universal Protocol Converter (UPC) Zone Sensors. Submittal Data English Language/IP Units SD1582EW 10/14
Zone Sensors Submittal Data English Language/IP Units SD1582EW 10/14 ZS Series RNet Zone Sensors ZS Series RNet Sensor Overview The ZS Series line of intelligent zone sensors provides the function and
More informationTemperature Control Panel Wiring Diagram Model: ISPA-120-1P-15A
Temperature Control Panel Wiring Diagram Model: ISPA-0-P-5A Shift Controls, Inc. Installed Options: TC Jack Panel Connector Interlock Relay, RLY- 5A Power Cord www.shift-controls.com support@shift-controls.com
More informationPVC motor cables unshielded
PVC motor cables unshielded LÜTZE-SILFLEX M PVC Motor connecting/energy supply cable Motor connecting cable and energy supply cable in machine and apparatus engineering, transport and conveyor technology,
More informationData sheet Patch cord Cat.6 A AWG m gray
Illustrations Dimensional drawing Page 1/6 See enlarged drawings at the end of document Product specification especially suitable for shielded and unshielded class E A systems fully shielded Cat.6 A patch
More informationFurutech - Pricelist
Furutech - Pricelist 01-03-2012 Item Description of goods IEC CONNECTORS SUGG RETAIL INCL TAX FI-15E(G) High Performance IEC connector 44,10 FI-15E(R) High Performance IEC connector 58,80 FI-11(R) - new
More informationENFORCER TM 6201-IQ ELECTRONIC SIREN
ENFORCER TM 6201-IQ ELECTRONIC SIREN INSTALLATION & OPERATION MANUAL CONTENT PAGE UNPACKING 2 INTRODUCTION 2 STANDARD FEATURES 2 INSTALLATION & MOUNTING 3 MOUNTING THE ENFORCER TM 6201 3 WIRING & ADJUSTMENTS
More informationArndt & Voß GmbH Elektronik - Meßtechnik
torque measuring unit Contents: Page 1. Functions 1 2. Components 2 3. Connection and control elements 3 4. Operating Mode 4 Torque measuring with bar graph 5 Single value chart 6 5. Selection of Setup
More informationOperating voltage up to 5 kvdc Operating current up to 4,5 A 2-6 high voltage contacts Quick and easy assembling Protection class IP68 acc.
Operating voltage up to 5 kvdc Operating current up to 4,5 A 2-6 high voltage contacts Quick and easy assembling Protection class IP68 acc. DIN EN 60529 General characteristics and technical data Series
More informationFilm-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment.
Film-Tech The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment. These manuals are designed to facilitate the exchange of information related to cinema
More informationTechnical Installation Manual
Lighting Step and Aisle Safety Lighting Technical Installation Manual 1 Contents Page 3 Tools required 4 Installation detail & planning 5 Adhesives, silicone & crimps 6 General cinema layout 7 Basic wiring
More informationTechnical Data Sheet Shielded (CY) PVC Control Cable
MachineTuff Cables Tinned Copper Braid Shield (TCB) Excellent Noise Immunity Applications Designed for applications which are installed in occasional flexing and fixed locations. Cable applications include
More informationINSTALLATION INSTRUCTIONS FOR Owner's Copy FILTERED AND REGULATED POWER SUPPLY VOLTS DC INPUT: Hz.
103158 March 9, 2011 FOR INDOOR USE ONLY Detex Corporation, 302 Detex Drive, New Braunfels, Texas 78130-3045 (830)629-2900 / 1-800-729-3839 / Fax (830)620-6711 E-MAIL: detex@detex.com INTERNET: www.detex.com
More informationSAVE THESE INSTRUCTIONS
READ AND FOLLOW ALL SAFETY INSTRUCTIS! SAVE THESE INSTRUCTIS AND DELIVER TO OWNER AFTER INSTALLATI IMPORTANT SAFETY INSTRUCTIS WARNING To reduce the risk of death, injury or property damage from fire,
More informationEco-Propel TM Variable Speed Pump Kit Instruction and Operation Manual, p/n Revision 0
Eco-Propel TM Variable Speed Pump Kit Instruction and Operation Manual, p/n 107065-01 Revision 0 May 20, 2016 Contents Introduction 2 Installation Pre-installation 3 Installation Procedure 4 Electrical
More informationElectronic Sensors Solid State, Reed and Proximity Sensors Feedback Packages
Electronic Solid State, Reed and Proximity Feedback Packages & Feedback Contents Hall Effect... 2 Reed Switches... 3 Cordsets... 4 Proximity... 5 Feedback Packages... 8 1 Sensor Specifications Solid State
More informationData sheet E-DAT modul Cat.6 A 8(8) jack, T568A
Illustrations Dimensional drawing Cut-out Page 1/7 See enlarged drawings at the end of document Product specification modular termination unit Cat.6 A, RJ45 component testing for Cat.6 A to ISO/IEC 11801
More informationL I G H -T. Product presentation V
L I G H -T Product presentation V2.0 08.2017 General Description Overall Presentation Ligh-T is a rugged tethered station for multirotor drones. This compact and robust solution enables the transmission
More informationKramer Electronics, Ltd. USER MANUAL. Model: FC-31. UXGA to DVI Converter
Kramer Electronics, Ltd. USER MANUAL Model: FC-31 UXGA to DVI Converter Contents Contents 1 Introduction 1 2 Getting Started 1 2.1 Quick Start 2 3 Overview 3 4 Your FC-31 UXGA to DVI Converter 3 4.1 Dipswitch
More informationInstallation Instructions
AQU244 & AQU128 Series Installation Instructions Installation Instructions AQU244 24vdc 5A Supervised Power Supply/Charger module AQU128 12vdc 10A Supervised Power Supply/Charger module Both Mounted in
More informationEZ-View Flow Meters. With Flow-Alert TM Flow Switch REDUCE MAINTENANCE COSTS TEL
With Flow-Alert TM Flow Switch Reed switch and latching models Automatically signals alarm if flow is too high or too low Models available for AC or DC power supply Latching models include Hirschmann type
More informationAMPLIMITE* HDP- 20 and Economy
AMPLIMITE* HDP- 20 and Economy Application Specification Crimp Snap Subminiature D 114-40030 Commercial s 05 MAY 11 Rev D NOTE i All numerical values are in metric units [with U.S. customary units in brackets].
More informationChapter 3 Solar PV Panel: Components Details and Fabrication
Chapter 3 Solar PV Panel: Components Details and Fabrication Background After deciding the idea of position of Solar PV Panel, the next step is to conceptualize and fabricate one module and deploy it on
More informationDry Contact Closure Interface
Dry Contact Closure Interface Overview LuXout Shades Dry Contact Closure Contact closure interfaces allows integration of the Automation systems throughout the house. The contact closure interface communicates
More informationPVM 220 Installation Guide
R CONFIG SELECT AUDIO 1 3 5 2 4 AUX INPUT VOICELIFT PAGING SENSOR SENSITIVITY PVM 220 Installation Guide The Extron PVM 220 is an enclosure for the safe mounting of PoleVault system devices in the plenum
More informationTechnical Data Sheet Shielded (CY) PVC Control Cable
Technical Data Sheet Shielded (CY) PVC Control Cable MachFlex 350 CY VDE Registered Tinned Copper Braid Shield (TCB) Excellent Noise Immunity Applications Designed for applications which are installed
More informationNoran Tel. Fuse Panel Technical Practice N NCY 4/4TPA & 6/6 GMT NEBS Level 3 Certified
0406-03E August 11, 2005 Fuse Panel Technical Practice N215120-NCY 4/4TPA & 6/6 GMT NEBS Level 3 Certified FEATURES Compatible with +24V, +48V, -24V or -48V dc input voltages (battery voltages). 2 busses
More informationCATENARY ACCESSORIES INSTRUCTIONS. Power Management. Quick Connect Voltage Separation Box AY-QCVSB. Sheet 5. Suspension Accessories
CATENARY ACCESSORIES INSTRUCTIONS Quick Connect Jumper Cord AY-QC7P6-X Sheet 2 Quick Connectors AY-QC7SET Sheet 3 3/32" Stainless Steel Cable AY-CBL3/32-50 Power Cord AY-P6-50 Power Cord Ties AY-WT-100
More informationData sheet. E-DAT modul Cat.6A 8(8) jack, T568A. Illustrations P/N I EAN Product specification. Page 1/
Page 1/9 Illustrations Dimensional drawing Cut-out See enlarged drawings at the end of document Product specification modular termination unit Cat.6A, RJ45 component testing for Cat.6A to ISO/IEC 11801
More informationGeneral characteristics and technical data Series MCS
MOD M MC MCS VP 100 S Operating voltage up to 5 kvdc Operating current up to 4,5 A 2-6 high voltage contacts Quick and easy assembling Protection class IP68 acc. DIN EN 60529 General characteristics and
More informationIEC INSTALLATION INSTRUCTION AND MAINTENANCE MANUAL FOR CRYSTALLINE SOLAR PV MODULE
AND MAINTENANCE MANUAL FOR CRYSTALLINE SOLAR PV MODULE AUTHOR(S): Bypina Veerraju Chaudary, Andy Nguyen, Yang Xiaowu Page 1 of 14 1. INTRODUCTION This installation instruction manual provides information
More informationSwitches 10AX/16AX. Safety. Easy Operation. Switch Mechanism. Characteristics of Urea Resin. Screwless Terminal (reduces installation work) Features
FLATIMA SERIES Switches 0AX/6AX Way Switch Intermediate Switch Push Button Safety PBT Resin Silver Alloy Contact Superior Arc Resistance and Anti-Deposition Properties Spring with Double Contact Points
More information2016 Photovoltaic Solar System Plan Review List
Building Division 555 Santa Clara Street Vallejo CA 94590 707.648.4374 2016 Photovoltaic Solar System Plan Review List GENERAL PROJECT INFORMATION PLAN CHECK NO DATE JOB ADDRESS CITY ZIP REVIEWED BY PHONE
More informationTurbotron // VTH15, VTM15, VTP15, VTI15
1 Flow Measuring Turbine flow sensors Turbotron // VTH15, VTM15, VTP15, VTI15 VTH15 BEST SELLER VTM15 Your advantages Series VTH15 VTM15 Cost optimized version For medium temperature up to 120 C Type VTH15
More informationData sheet. E-DAT modul Cat.6A 8(8) jack, T568A. Illustrations P/N I EAN Product specification. Page 1/
Page 1/9 Illustrations Dimensional drawing Cut-out See enlarged drawings at the end of document Product specification modular termination unit Cat.6A, RJ45 component testing for Cat.6A to ISO/IEC 11801
More informationKramer Electronics, Ltd. USER MANUAL. Model: K-Able Box. Cable Retractor
Kramer Electronics, Ltd. USER MANUAL Model: K-Able Box Cable Retractor Contents Contents 1 Introduction 1 2 Getting Started 1 2.1 TBUS Compatibility 2 2.2 Recycling Kramer Products 2 2.3 Quick Start 3
More information06. har-mik INTERFACE CONNECTORS
. INTERFACE CONNECTORS Miniature D connectors are a must in various cableto-board applications where space saving and high data transfer rates are required. For the purposes of miniaturization and speed,
More informationPowerMax. Power Distribution System. Operation Manual Version 1.0 Copyright 2003 Professional Sound Corporation Printed in the U.S.A.
PowerMax Power Distribution System Operation Manual Version 1.0 Copyright 2003 Professional Sound Corporation Printed in the U.S.A. Thank you for purchasing the Professional Sound Corporation PowerMax
More informationSolenoid Valve Island Type 3965
Solenoid Valve Island Type 365 for the control of pneumatic actuators General The Type 365 Solenoid Valve Island is a compact solution for the centralized control of pneumatic actuators in chemical and
More informationINSTALLATION. Figure 1. Figure 2.
THANK YOU for choosing the JBL BassPro II. BassPro II has been designed to deliver great bass performance from a compact, easily installed powered subwoofer enclosure. To get the best performance from
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS WARNING: WARNING: www.altronicinc.com DEVIATION DEVIATION FROM THESE FROM INSTRUCTIONS THESE INSTRUCTIONS MAY LEAD MAY TO LEAD IMPROPER TO IMPROPER OP- ERATION OF ENGINE THE MACHINE
More informationTechnical Data Sheet Unshielded (YY) PVC Control Cable
MachineTuff Cables Applications Designed for applications which are installed in occasional flexing and fixed locations. Cable applications include precision control sensors, multi axis control machines,
More informationData sheet C6 A RJ45 field plug pro
Illustrations Dimensional drawing Page 1/6 See enlarged drawings at the end of document Product specification Cat.6 A class E A RJ45 plug to be assembled in the field fully shielded and multi-port capable
More informationDual MaxDim Installation Instructions
Dual MaxDim Installation Instructions PARTS SUPPLIED 9100-001-C: P/N 9100-001-C & 9100-001-D 1 ea Dual MaxDim Control P/N 9100-001-C, including STC logbook copy 1 ea Fully Insulated Red Female Crimp on
More informationTechnical Data Sheet Shielded (CY) PVC Control Cable
Technical Data Sheet Shielded (CY) PVC Control Cable MachFlex 375 CY Tinned Copper Braid Shield (TCB) Excellent Noise Immunity Applications Designed for applications which are installed in occasional flexing
More informationData sheet. E-DAT Industry RJ45 field plug PROFINET. Illustrations P/N PI EAN Product specification. Page 1/
Page 1/7 Illustrations Dimensional drawing Wiring See enlarged drawings at the end of document Product specification multi-port Cat.5 plug to be assembled in the field 100 MBit suitable according to IEEE
More informationFlow switches for insertion installation
Flow switches for insertion installation Threaded adapter with trimmable paddle Type VHS06 Type VK306 Technical data VHS06 VK306 Switching function Contact closes at increasing flow opens at decreasing
More informationE.S.P. Embedded Sensing Probes for Motor Brushes
E.S.P. Embedded Sensing Probes for Motor Brushes 2/13 Installation & Operating Manual MN609 Any trademarks used in this manual are the property of their respective owners. Important: Be sure to check www.baldor.com
More informationEco-Propel TM Variable Speed Pump Kit Instruction and Operation Manual, P/N: , Revision 1
Eco-Propel TM Variable Speed Pump Kit Instruction and Operation Manual, P/N: 107065-01, Revision 1 March 03, 2017 Contents Introduction 2 Installation Pre-installation 3 Installation Procedure 4 Electrical
More informationEaton Corp. - Marina Power and Lighting, Inc. General Specifications for Newport Harbor Mate Utility Center
Newport Harbor Mate Dimensions Height: 14.50" (368.30 mm) Width: 10.50" (266.70 mm) Depth: 10.40" (264.16 mm) Newport Harbor Mate Utility Center Diagram 2.77" Approximate Weight: 11 lbs. (5.0 kg) 10.31"
More informationSunLink PV System Disconnect with Arc Fault Detection Installation and Operations Manual
Combiner Box Installation & Operations Manual SunLink PV System Disconnect with Arc Fault Detection Installation and Operations Manual TABLE OF CONTENTS Notices and Safety Precautions Pages 1-2 Combiner
More informationType A-10 General Purpose Pressure Transmitters
Type A-10 General Purpose Pressure Transmitters Applications Mechanical engineering Machine tools Process control and automation Hydraulics and pneumatics Pumps and compressors Special Features Pressure
More informationGMT Fuse Panel Installation Guide
GMT Fuse Panel Installation Guide Document INS-707XXXXXXX This manual covers the following part numbers- Trimm 707XXXXXXX Family Table of Contents Section 1- General Information... 3 1.1 - Product Description...
More informationData sheet E-DAT Industry patch cord V6 IP67 - RJ m
Illustrations Dimensional drawing Page 1/6 See enlarged drawings at the end of document Product specification fully shielded Cat.6 patch cable AWG 26/7 S/FTP with PUR cable sheath 1 x RJ45 and 1 x RJ45-IP67-V6
More informationTotal Front Access Wall Mount Fuse Panel Installation Guide. Document INS This manual covers the following part numbers
Total Front Access Wall Mount Fuse Panel Installation Guide Document INS-7473121031 This manual covers the following part numbers- 7473121031 Table of Contents Section 1- General Information... 3 1.1 -
More informationREMOTE POWERING Central Energy System ( HUB )
/ 0 REMOTE POWERING Central Energy System ( HUB ) User Guide Mitra E&I SCA Wavre Belgium 009 Subject to modifications without notice / 0 Content RECTIFIER SYSTEM - USER MANUAL The information and pictures
More informationHigh Frequency SineWave Guardian TM
High Frequency SineWave Guardian TM 380V 480V INSTALLATION GUIDE FORM: SHF-IG-E REL. January 2018 REV. 002 2018 MTE Corporation High Voltage! Only a qualified electrician can carry out the electrical installation
More informationMaxDim Installation Instructions
MaxDim Installation Instructions PARTS SUPPLIED 9100-001-A: P/N 9100-001-A & 9100-001-B 1 ea Dimmer Control P/N 9100-001-A, including STC logbook copy 1 ea Fully Insulated Red Female Crimp on Connectors
More informationPITNEY BOWES Sure-Feed Engineering SURE JET MODEL SJVB - TUV. Parts Manual. SJVB-TUVparts 1
SURE JET MODEL SJVB - TUV Parts Manual SJVB-TUVparts 1 TABLE OF CONTENTS SURE JET- SJVB-TUV SURE JET VACUUM BASE ASSEMBLY (FIG. 1)..... 5 FRAME ASSEMBLY (FIG. 2). 7 CONVEYOR DRIVE ASSEMBLY (FIG. 3).. 9
More informationEaton Corp. - Marina Power and Lighting, Inc. General Specifications for Hatteras Light Pedestals
Hatteras Light Power Pedestal Dimensions Height: 31.00" (787.40 mm) Width: (190.50 mm) Depth: (190.50 mm) Hatteras Light Base Diagram Approximate Weight: 14 lbs. (6.4 kg) 1.73" UL FILE # E133781 Ø0.41
More informationCONSUMABLES POWER 099 POWER CONNECTIONS 108 FUSES 115 CIRCUIT BREAKERS 116 FUSE HOLDERS 126 RELAYS & FLASHER UNITS 131 SOLENOIDS 132 JUNCTION BOXES
POWER CONSUMABLES POWER CONSUMABLES // PRODUCT FINDER 099 POWER CONNECTIONS 108 FUSES 115 CIRCUIT BREAKERS 116 FUSE HOLDERS 126 RELAYS & FLASHER UNITS 131 SOLENOIDS 132 JUNCTION BOXES With one of the most
More informationINSTRUCTIONS. Power Panel. Installation Instructions
Overview LuXout Shade 18 Output - For use with LuXout Shades NOTICE: This power supply is built-in fan on/off control circuit. Fan automatically works according to working temperature. SHOCK HAZARD Risk
More informationSITRANS AS 100. Instruction Manual September 2001 ITRANS AS 100
SITRANS AS 100 Instruction Manual September 2001 ITRANS AS 100 Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the
More informationVD0C06N908C July 1998 Raleigh, NC, USA. Instruction Bulletin ALTIVAR 66, ALTIVAR 58, ALTIVAR 18. Dynamic Braking Resistor Kit User s Manual
Instruction Bulletin VD0C06N908C July 1998 Raleigh, NC, USA ALTIVAR 66, ALTIVAR 58, ALTIVAR 18 Dynamic Braking Resistor Kit User s Manual DANGER HAZARDOUS VOLTAGE Read and understand this bulletin in its
More informationDatasheet. Approvals. Technical data. Feed-through terminal WK 4 / U BLUE /V0. General. Technical data. Connection Data
Datasheet Art.No. 57.504.0055.6 Feed-through terminal WK 4 / U BLUE /V0 Feed-through DIN rail terminal block with screw connection for mounting on TS 35 and TS 32, nominal cross section 4 mm², width 6
More informationPRESSURE BENCH OPERATING INSTRUCTIONS
PRESSURE BENCH OPERATING INSTRUCTIONS Overview: The pressure bench system allows the user to apply a variety of calibrated pressures to a variety of high and low pressure transducers. In addition the system
More informationAnti-spatter Inductive Prox E2EQ. Ordering Information. Weld-Sputter Resistant DC 2-Wire Cylindrical Sensors. H Rugged fluoroplastic coated brass
R Anti-spatter Inductive Prox Weld-Sputter Resistant DC 2-Wire Cylindrical Sensors H Rugged fluoroplastic coated brass barrel withstands high tightening torque H Fluoroplastic resin face prevents weld
More information127 (5) Approx (1.85) Overmold. Male Coupling Nut. Straight Micro Female 63.5 (2.5) 127 (5) Approx. Overmold Coupling Nut Straight Mini Female
KwikLink Lite Flat Drop General Quick Selection Introduction KwikLink Lite Drop Cordset with 4-wire unshielded cable. Device connection options include 5 pin mini and micro as well as flying leads. Physical
More informationData Sheet. A-Series Miniature Watertight Pressure Switches. Factory set or field adjustable
FEATURES Compact size 36 stainless steel construction Pressure ranges from vacuum to 5,000 psi Factory set or field adjustable setpoints Wide operating temperature range ( 40 C to 00 C) Precision snap-acting
More informationSeismic Sensor Accessories SA, SV & ST 6000 Series
Seismic Sensor Accessories SA, SV & ST 6000 Series Part Number Name Used With Description Housing Material 7295-002 Accelerometer EP Housing SA6200A-X0X; SV6300A-001 Physical protection and access to 1/4-28
More informationAMPLIMITE.050 Series Cable Assemblies, Series III
Cable Assemblies, Series III To meet Standard Applications the following 106 ohm, black jacketed cable assemblies are available. For AMPLIMITE Series cable assemblies that meet other impedance requirements
More informationEx-proof proportional relief valves Direct or pilot operated, without transducer - ATEX, IECEx, EAC or CULUS
Table FX1-/E Replaces F6-5 /E E125-16 /E Ex-proof proportional relief valves Direct or pilot operated, without transducer - ATEX, IECEx, EAC or CULUS Valve main body Cartridge Mechanical pressure limiter
More informationPRESSURE TRANSDUCERS. Specifications. Individual Specifications
00 Series and 00 Heavy Duty Series Compact OEM Pressure Transmitters 0 50 psi to 0-0,000 psi ranges (0-.5 bar to 0-,00 bar) High Proof Pressures Broad Choice of Outputs RoHS Compliant For OEMs that need
More informationLED Downlight Ceiling Fixtures
ED Downlight Ceiling Fixtures Every attempt has been made to ensure that this documentation is as accurate and up-to-date as possible. However, Vertical Express assumes no liability for consequences, directly
More informationInstallation Instructions & Users Manual
Installation Instructions & Users Manual UTILITY/ BUILDING INPUT 120 VAC ( OPTION) 15-20A N L CONTROL BOARD G SECURITY LIGHTING POWER SUPPLY (OPTION) CHARGER- POWER SUPPLY ASSBY XFMR (OPTION) CBM MODEL
More informationThe WDS A Dimmer Users Manual Rev , 2012 City Theatrical, Inc.
The WDS 5520 15A Dimmer Users Manual Rev 1 2007, 2012 City Theatrical, Inc. CONTENTS COMPLIANCE INFORMATION... 3 Safety Notices... 3 Setup and Controls... 4 Connections... 5 Protective Features... 5 Switch
More informationManual. EN Appendix. Lynx Ion BMS 400A / 1000A
Manual EN Appendix Lynx Ion BMS 400A / 1000A 1. SAFETY INSTRUCTIONS 1.1 In general Please read the documentation supplied with this product first, so that you are familiar with the safety signs en directions
More informationEPIC CIRCON M23 Series
CIRCON M23 Series Application Advantage Rugged nickel-plated, die-cast zinc body Positive vibration protection for use with motor drives and moving assemblies Integral EMC cable gland provides strain relief,
More informationCompetition. grade specs SUBWOOFERS
SUBWOOFERS Aluminum diecast chassis High flux ferrite magnet system 3 Kapton voice coil (10 &12 ) 2 Kapton voice coil (15 ) Fiber cone Competition grade specs NRG10 NRG12 Diameter 10 (270mm) 12 (321.5mm)
More informationData sheet Connection line M12 plug straight - RJ45 plug straight 8-pole, X-coded 5.0 m
Page 1/5 Illustrations Dimensional drawing See enlarged drawings at the end of document Product specification shielded M12-plug to RJ45-plug connection line Cat.6, 8-pole M12-connector, X-coded, straight
More information