1 s flow sensors 711/A and 711/911E flow sensors 711/A and 711/911E Introduction Application Mode of operation, operation Mode of operation All electromagnetic flow measurements are based on Faraday s Law of Induction: U m = B v d Sensor Fig. 1 flow sensor Fig. 2 Measuring principle Application Electromagnetic flowmeters are suitable for measuring the flow of almost all electrically conducting liquids, as well as sludges, pastes and slurries. A prerequisite is that the medium must have a certain minimum conductivity. The temperature, pressure, viscosity and density have no influence on the result. Even corrosive media can be measured providing suitable materials are selected for the tube liner and the electrodes. Solids present in the medium do not usually influence the result. The main applications of the flow sensors can be found in the following fields: Water, waste water Power generation and distribution Chemical and pharmaceutical industries Food industry The flow sensors are combined with the transmitters Intermag/Transmag produce a complete unit. Intermag/Transmag are available as compact and remote versions. U m = measured voltage produced perpendicular the magnetic field and the flow direction. The voltage is tapped at two point electrodes B = magnetic flux density which permeates the flowing medium perpendicular the flow direction v = flow velocity of medium d = internal diameter of metering tube An electric voltage is induced in a conducr moving through a magnetic field. The magnetic field is generated by coils in the sensor, and is propagated in the pipeline. The flowing medium (as the moving conducr) generates a voltage in the magnetic field. This voltage is proportional the velocity, and can be tapped at the sensor electrodes. A differentiation is made between constant field and alternating field excitation for the type of magnetic field. Special features of the flow sensors: Smooth passage through metering tube without reduction in cross-section No influence of temperature, viscosity and pressure No influence of conductivity of medium above the minimum conductivity Suitable for pipe cross-sections up mm (80") Various pipe liners (rubber, PTFE, Novolak) Electronic moniring of electrodes Integral smartplug for saving calibration values and sensor data Operation Information on operation can be found in the data sheet for the transmitters Intermag/Transmag. Siemens AG Siemens Supplement Catalog FI 01 March 1

2 flow sensors 711/A and 711/911E Introduction Installation guidelines Installation guidelines The measuring principle is independent of the flow profile providing stationary eddies do not extend in the zone where the measured value is generated (e.g. following elbows, with a tangential restriction or with a half-opened gate valve upstream of the sensor). In such cases, measures are required stabilize the flow profile: Increase the upstream and downstream distances Use a flow straightener Fig. 5 Installation with pipeline which is always full The flow sensor should be installed such that the metering tube cannot run empty and is always full with the medium. If the pipeline is not full or if there is a open outlet, the sensor must always be installed in a siphon (Fig. 5). Fig. 3 Installation in horizontal and vertical pipelines Installation is possible horizontally or vertically (Fig. 3), but it should be ensured that the electrode axes are horizontal in order avoid faulty measurements as a result of deposits or bubbles on the electrodes. Fig. 6 Installation in pipelines which can run empty With an open outlet, the flow sensor should not be fitted in sections of the pipeline which can run empty. When installing in a downward pipeline, it must be ensured that the pipeline is 100% full with medium. min. 5 D min. 5 D min. 10 D min. 20 D min. 20 D min. 5 D Fig. 4 Installation between elbows, valves and pumps The straight upstream and downstream distances must be observed (Fig. 4). Fig. 7 Installation at highest point Installation at the highest point in a pipeline should be avoided because of the possible accumulation of bubbles. 2 Siemens Supplement Catalog FI 01 March

3 flow sensors 711/A and 711/911E Technical data flow sensors 711/A and 711/911E Technical data Application See page 1 Mode of operation and design See page 1 Measuring principle 711/A Pulsed constant field (DC) 711/911E Pulse constant field (DC), pulsed alternating field (AC) Input s 711/A 300 (½ 12 ) 711/911E (½ 80 ) Metering tube connections DIN 2501, ANSI B16.5, others on request Rated operating conditions Installation conditions See page 2 Ambient conditions Max. operating temperature With rubber liner 90 C / optionally 100 C With PTFE liner 180 C (at 16 bar) 150 C (at 25 bar) 100 C (at 40 bar) With Novolak liner 130 C (at 40 bar) 711/A IP 67 NEMA 5/ optionally IP 68 NEMA 6 711/911E IP 65 NEMA 4/ optionally IP 68 NEMA 6 Medium conditions Minimum conductivity 711/A > 3 µs/cm 911E For constant field >3 µs/cm For alternating field >0.008 µs/cm (dependent on medium and flow velocity) Maximum flow velocity 12 m/s Full-scale value of flow velocity 711/A 0,25 12 m/s with constant field 711/911E 0,15 12 m/s with constant and alternating fields Version Fully-welded steel fitting Weight See tables on pages 4 and 5 Cable inlet Only for remote version: Pg screwed gland for DIN flanges, NPT screwed gland for ANSI flanges Material Metering tube Stainless steel Sensor housing Steel Flange Steel/optionally stainless steel Metering tube liner Hard rubber, soft rubber, neoprene, PTFE, Novolak Electrodes Material Stainless steel , Hastelloy C4, titanium, tantalum, nickel, platinized (others on request) - 711/A Standard: flat electrodes With special material: tip electrodes - 711/911E Standard: flat electrodes DN 32 and above: tip electrodes, optionally removable electrodes Gasket Vin, EPDM, Kalrez Certificates and approvals Ex protection - 711/A Available soon - 711/911E On request, but not gether with transmitters Intermag/Transmag Equipotential bonding Protection washers, earthing rings and protection rings (inlet/ outlet protection) are available as accessories. Protection washers are attached as standard all sensors lined with PTFE protect the liner. They can also be used as earthing rings. Protection rings protect the inlet and outlet edges of the sensor from mechanical damage, especially with abrasive media, and simultaneously serve as earthing rings. With electrically conducting pipelines it is guaranteed that the medium, the pipeline and the transmitter are connected in the sense of equipotential bonding. With internally insulated pipelines, the medium in the pipeline must be connected a reference potential by additional measures. This is possible using earthing rings or protection washers. Siemens Supplement Catalog FI 01 March 3

4 flow sensors 711/A and 711/911E Technical data Dimensions 80 H Flow direction B L D Fig. 8 flow sensor 711/A, dimensions (in mm) DN15 DN20 DN25 DN32 DN40 DN50 DN65 DN80 DN100 DN125 DN150 DN200 DN250 DN300 ½ ¾ 1 1 ¼ 1 ½ 2 2 ½ Built-in length L 1 ) Hard rubber version PTFE version without protection washers PTFE version with protection washers Novolak version (without protection washers) Dimensions of sensor housing Housing width B Housing diameter D Height of flat section H Weight (in kg) ) Tolerance for built-in length: 200: L +0/-3 mm; DN : L +0/-5 mm DN350 DN400 DN500 DN600 DN700 DN800 DN900 DN1000 DN1200 DN1400 DN1600 DN1800 DN Built-in length L 2 ) Hard rubber version PTFE version without protection washers PTFE version with protection washers Novolak version (without protection washers) Dimensions of sensor housing Housing width B Housing diameter D Height of flat section H Weight (in kg) ) Tolerance for the built-in length: L +0/-4 mm 4 Siemens Supplement Catalog FI 01 March

5 flow sensors 711/A and 711/911E Technical data Dimensions Fig. 9 flow sensor 711/911E, dimensions (in mm) DN A B 1 ) C C1 D Approx. weight in kg On request On request 1 ) With protection rings for DN mm, DN mm Siemens Supplement Catalog FI 01 March 5

6 flow sensors 711/A and 711/911E Technical data Reductions in the pipe are possible in order use the most favorable sensor diameter for the defined measuring range. The reduction angle should not exceed 8. Reductions result in additional pressure losses as shown in Fig. 10. d A = sensor pipe diameter d R = pipe diameter prior reduction Fig. 10 Pressure loss of sensor as function of nominal diameter and flow Series Rubber Novolak PTFE 711/A 711/911 E PN 10, PN 16, PN 25, PN40, PN 10, PN 16, PN 25, PN40, PN 10, 600 PN 16, 600 PN 25, 600 PN40, 600 MLFB Ord. No. 7 M E x 7 M E x 7 M E x 7 M E x x x 7 M E x x x 7 M E x x x Ex protection Constant field Alternating field Summary of electromagnetic flow sensors with the various liners, pressure ratings and nominal diameters. 6 Siemens Supplement Catalog FI 01 March

7 flow sensors 711/A and 711/911E Technical data Flow nomograms The volume flow depends on the flow velocity and the nominal diameter DN of the flowmeter. The nomograms (Figs. 11 and 12) shown which flow range can be measured by a sensor with a particular nominal diameter, and which nominal diameters are suitable for a particular flow. Example: Flow qv, max = 7 m3/h (maximum value = full-scale value of measuring range) Sensors with nominal diameters from DN 20 DN 65 are suitable. qv Flow Fig. 11 v Flow velocity Flow nomogram for nominal diameters DN 300 qv Flow Fig. 12 v Flow velocity $ Example Flow nomogram for nominal diameters DN Siemens Supplement Catalog FI 01 March 7

8 flow sensors 711/A and 711/911E Ordering data flow sensors 711/A and 711/911E flow sensor 711/A Rubber liner 7ME A flow sensor 711/A Rubber liner 7ME A70 Nominal pressure PN 10 PN 16/150 lb PN 25 PN 40 Compact, constant field Remote, constant field Liner Hard rubber - VHE/H3b - VHE/G31 (up 100 C) - VHE/181 (potable water) Soft rubber VWE/R61 Neoprene BWE/DN 63 Soft rubber VWE/KUA62 (potable water) DN 20 DN 25 DN 32 DN 40 DN 65 DN 80 DN 100 DN DN 200 DN 250 DN 300 DN 350 DN DN 600 DN 700 DN 800 DN 900 DN1000 Other nominal diameters: Connection flange - DIN 2501, mat. No / DIN 2501, mat. No ANSI B 16.5 RF, mat. No / ME ME ME ME ME ME ME ME ME ME ME ME ME A ME B ME C ME D ME E ME F ME G ME H ME J ME K ME L ME M ME N ME P ME Q ME R ME S ME T ME U ME V ME W ME X ME Z J1Y Protection washers, protection rings With protection washers (order as accessory) With protection rings (order as accessory) IP 67/NEMA5 (cable length 5 m) (cable length 10 m) Further designs Please add -Z and specify Order code(s). One earthing electrode made of mat. No up DN 300 Two earthing electrodes made of mat. No from DN 300 One earthing electrode up Two earthing electrodes from 7ME ME ME ME A B ME A C ME A D 7777 A01 A02 A03 A04 7ME A ME B ME ME C Electrode material Mat. No Hastelloy C4 (Mat. No ) Titanium Tantalum Nickel Platinum head with shaft mat. No Other materials: Gasket material Vin EPDM Kalrez 7ME ME ME ME ME ME ME ME L1Y 7ME ME ME Siemens Supplement Catalog FI 01 March

9 flow sensors 711/A and 711/911E Ordering data flow sensor 711/A Novolak liner 7ME A flow sensor 711/A PTFE liner 7ME A Nominal pressure PN 10 PN 16/150 lb PN 25 PN 40 Remote, constant field Compact, constant field DN 65 DN 80 DN 100 DN DN 200 DN 250 DN 300 DN 350 DN DN 600 DN 700 DN 800 DN 900 DN1000 Other nominal diameters: Metering tube connection Flange - DIN 2501, mat. No DIN 2501, mat. No ANSI B 16.5 RF, mat. No / Electrode material Mat. No Hastelloy C4 (mat No ) Titanium Tantalum Nickel Platinum head with shaft mat. No Other materials: Gasket material Vin EPDM Kalrez Protection washers, inlet/outlet protection With protection washers (order as accessory) With protection rings (order as accessory) IP 67/NEMA5 (cable length 5 m) (cable length 10 m) Further designs (see PTFE liner on the right) 7ME A ME A ME A ME A ME A ME A ME F 777-0A ME G 777-0A ME H 777-0A ME J 777-0A ME K 777-0A ME L 777-0A ME M 777-0A ME N 777-0A ME P 777-0A ME Q 777-0A ME R 777-0A ME S 777-0A ME T 777-0A ME U 777-0A ME V 777-0A ME5717-7W 777-0A ME5717-7X 777-0A A ME5377- Z A 7 0 J1Y 7ME A 77-0A ME B 77-0A ME ME C 7ME ME ME ME ME ME ME L1Y 7ME A ME A ME A ME ME ME ME A B ME A C ME A DD Nominal pressure PN 10 PN 16/150 lb PN 25 PN 40 Remote, constant field Compact, constant field DN 20 DN 25 DN 32 DN 40 DN 65 DN 80 DN 100 DN DN 200 DN 250 DN 300 DN 350 DN DN 600 DN 700 DN 800 DN 900 DN1000 Other nominal diameters: Metering tube connection Flange - DIN 2501, steel - DIN 2501, mat. No ANSI B 16.5 RF Electrode material Mat. No Hastelloy C4 (mat. No ) Titanium Tantalum Nickel Platinum head with shaft Other materials in plain text Protection rings With protection rings (required from PN 16, order as accessory) IP 67/NEMA5 (cable length 5 m) (cable length10 m) Further designs Please add -Z and specify Order code(s). One earthing electrode made of mat. No up DN 300 Two earthing electrodes made of mat. No from DN 300 One earthing electrode up Two earthing electrodes from 7ME A ME A ME A ME A ME A ME A ME A 777-0A ME B 777-0A ME C 777-0A ME D 777-0A ME E 777-0A ME F 777-0A ME G 777-0A ME H 777-0A ME J 777-0A ME K 777-0A ME L 777-0A ME M 777-0A ME N 777-0A ME P 777-0A ME Q 777-0A ME R 777-0A ME S 777-0A ME T 777-0A ME U 777-0A ME V 777-0A ME W 7ME X 777-0A ME5377- Z A7 J1Y 7ME A 77-0A ME B 7ME C 77-0A ME ME ME ME ME ME ME L1Y 7ME ME ME AB 7ME AC ME AD A01 A02 A03 A04 Siemens Supplement Catalog FI 01 March 9

10 flow sensors 711/A and 711/911E Ordering data flow sensor 711/911/E Rubber liner 7ME flow sensor 711/911/E Rubber liner 7ME Nominal pressure PN 10 PN 16/150 lb PN 25 PN 40 Compact, alternating field Compact, constant field Remote, alternating field Remote, constant field Liner Hard rubber - VHE/H3b - VHE/G31 (up 100 C) - VHE/181 (potable water) Soft rubber VWE/R61 Neoprene BWE/DN 63 Soft rubber VWE/KUA62 (potable water) 7ME ME ME ME ME ME ME ME ME ME ME ME ME ME Protection washers, protection rings With protection washers (order as accessory) With protection rings (order as accessory) Rem. elec (DN 100 and above) Replacable Replacable under pressure With built-in replacable ol IP 65/NEMA4 IP 67/NEMA5 (cable length 5 m) (cable length 10 m) 7ME ME ME ME A ME B ME C ME D ME A ME B ME C ME D 7777 DN 20 DN 25 DN 32 DN 40 DN 65 DN 80 DN 100 DN DN 200 DN 250 DN 300 DN 350 DN DN 600 DN 700 DN 800 DN 900 DN1000 Other nominal diameters: Connection flange - DIN 2501, mat. No / DIN 2501, mat. No ANSI B 16.5 RF, mat. No / ME A ME B ME C ME D ME E ME F ME G ME H ME J ME K ME L ME M ME N ME P ME Q ME R ME S ME T ME U ME V ME W ME X ME Z J1Y Explosion protection EEx e [ib] IIC T3-T6 up max. 150 C Further designs Please add -Z and specify Order code(s). One earthing electrode made of mat. No up DN 300 Two earthing electrodes made of mat. No from DN 300 One earthing electrode up Two earthing electrodes from 7ME ME A01 A02 A03 A04 7ME A ME B ME ME C Electrode material Mat No Hastelloy C4 (mat. No ) Titanium Tantalum Monel Platinum head with shaft mat. No Other materials: Gasket material Vin EPDM Kalrez 7ME ME ME ME ME ME ME ME L1Y 7ME ME ME Siemens Supplement Catalog FI 01 March

11 flow sensors 711/A and 711/911E Ordering data flow sensor 711/911/E Novolak liner 7ME A flow sensor 711/911/E Novolak liner 7ME A 77 Nominal pressure PN 10 PN 16/150 lb PN 25 PN 40 Compact, alternating field Compact, constant field Remote, alternating field Remote, constant field DN 65 DN 80 DN 100 DN DN 200 DN 250 DN 300 DN 350 DN DN 600 DN 700 DN 800 DN 900 DN1000 Other nominal diameters: 7ME A ME A ME A ME A ME A ME A ME A ME A ME F 777-0A ME G 777-0A ME H 777-0A ME J 777-0A ME K 777-0A ME L 777-0A ME M 777-0A ME N 777-0A ME P 777-0A ME Q 777-0A ME R 777-0A ME S 777-0A ME T 777-0A ME U 777-0A ME V 777-0A ME W 777-0A ME X 777-0A ME Z 777-0A777J1Y Protection washers, protection rings With protection washers (order as accessory) With protection rings (order as accessory) IP 65/NEMA4 IP 67/NEMA5 (cable length 5 m) (cable length 10 m) Explosion protection EEx e [ib] IIC T3-T6 Further designs Please add -Z and specify Order code(s). One earthing electrode made of mat No up DN 300 Two earthing electrodes made of mat. No from DN 300 One earthing electrode up Two earthing electrodes from 7ME ME ME ME A A 7 7ME A B 7 7ME A C 7 7ME A D 7 7ME A 7 0 7ME A 7 1 A01 A02 A03 A04 Connection flange - DIN 2501, mat No / DIN 2501, mat No ANSI B 16.5 RF, mat. No / ME A 77-0A ME B 77-0A ME ME C Electrode material Mat No Hastelloy C4 (W.-Nr ) Titanium Tantalum Nickel Platinum head with shaft mat No Other materials: 7ME A ME A ME A ME A ME A ME A77 7ME L1Y Gasket material Vin EPDM Kalrez 7ME A ME A ME A77777 Siemens Supplement Catalog FI 01 March 11

12 flow sensors 711/A and 711/911E Ordering data flow sensors 711/A and 711/911E flow sensor 711/911/E PTFE liner 7ME A flow sensor 711/911/E PTFE liner 7ME A77 Nominal pressure PN 10 PN 16/150 lb PN 25 PN 40 7ME53 1 7ME53 2 7ME53 3 7ME53 4 Protection rings With protection rings (required from PN 16 upward, order as accessory) 7ME ME Compact, alternating field Compact, constant field Remote, alternating field Remote, constant field DN 25 DN 32 DN 40 DN 65 DN 80 DN 100 DN DN 200 DN 250 DN 300 DN 350 DN DN 600 Other nominal diameters: Connection flange - DIN 2501, mat. No / DIN 2501, mat No ANSI B 16.5 RF, mat No / ME ME ME ME ME5377-0C 7ME D 7ME E 7ME F 7ME5377-0G 7ME5377-0H 7ME J 7ME K 7ME L 7ME M 7ME5377-0N 7ME5377-0P 7ME5377-0Q 7ME R 7ME S 7ME T 7ME5377-7ME5377-0Z770-0 A77 J1Y 7ME A 7ME B 7ME ME C IP 65/NEMA4 IP 67/NEMA5 (cable length 5 m) (cable length 10 m) Explosion protection EEx [ib] e IIC T3-T6 up 0 for constant field EEx em [ia] IIC T3-T4 up 0 for alternating field Further designs Please add -Z and specify Order code(s). One earthing electrode made of mat. No up DN 300 Two earthing electrodes made of mat. No from DN 300 One earthing electrode up DN 300, mat in plain text Two earthing electrodes from DN 300, mat in plain text 7ME A A 7ME A B 7ME A C 7ME A D 7ME A 7 0 7ME A 7 1 7ME A 7 2 A01 A02 A03 A04 Electrode material Mat. No Hastelloy C4 (W.-Nr ) Titanium Tantalum Nickel Platinum head with shaft mat. No Other materials: 7ME ME ME ME ME ME ME L1Y http: // Siemens AG Aumation and Drives Group (A&D) Process Aumation and Instrumentation Karlsruhe Tel / Fax / Siemens Aktiengesellschaft Siemens AG Subject change E86060-K6201-E111-A KG SR 12 En

Magnetic-inductive flow meter EPS / UMF2. Technical data sheet

Magnetic-inductive flow meter EPS / UMF2. Technical data sheet Magnetic-inductive flow meter EPS / UMF2 Technical data sheet high accuracy: 0.3 % of actual maintenance-free no pressure drop numerous lining materials numerous electrode materials low-cost grounding

More information

Magnetic-inductive flow meter for hazardous areas

Magnetic-inductive flow meter for hazardous areas Magnetic-inductive flow meter for hazardous areas Technical Datasheet EPX / UMF3 high accuracy: 0.3 % of actual maintenance-free no pressure drop numerous lining materials numerous electrode materials

More information

Magnetic Inductive Flowmeter EP / UMF2 (B)

Magnetic Inductive Flowmeter EP / UMF2 (B) Magnetic Inductive Flowmeter EP / UMF2 (B) High accuracy 0.3 % of reading No maintenance required no pressure drop different lining materials different electrode materials inexpensive earthing electrode

More information

유량계전문제조업체. Electro Magnetic FLOWMETER

유량계전문제조업체. Electro Magnetic FLOWMETER 유량계전문제조업체 w w w. f c k o r e a i n s. c o m Electro Magnetic FLOWMETER ELECTRO-MAGNETIC FLOW METER Contents Principle of Operation 04 Grounding Method 05~07 Piping Installation 08 CN-400 CNT-2 Flanged

More information

SITRANS F flowmeters SITRANS F C MASSFLO MASS MC1. 4/146 Siemens FI Overview

SITRANS F flowmeters SITRANS F C MASSFLO MASS MC1. 4/146 Siemens FI Overview Overview MSS 2100 MC1 DN 50 to DN 150 (2 to 6 ) is suitable for accurate mass flow measurement for all kind of liquids and gases. The sensor offers superior performance in terms of flow accuracy, turn-down

More information

Electromagnetic flowmeters Series FLOMID Electromagnetic flowmeter for conductive liquids

Electromagnetic flowmeters Series FLOMID Electromagnetic flowmeter for conductive liquids Electromagnetic flowmeters Series FLOMID Electromagnetic flowmeter for conductive liquids Flow rate measurement is independent of density, temperature, viscosity and pressure Pulsed coil excitation to

More information

Product Data Sheet 2012 Rev 5 FLOWMETRIX SA SAFMAG Electromagnetic Flowmeter Doc Date

Product Data Sheet 2012 Rev 5 FLOWMETRIX SA SAFMAG Electromagnetic Flowmeter Doc Date FLOWMETRIX SA Doc Date 17.07.2012 PERFORMANCE * 0,5% of rate (Standard) * 0,25% of rate (Optional) * 1000 : 1 operable flow range * Excellent repeatability * Optional Bi-directional measurement * Advanced

More information

Food & beverage. Oil & gas. Water & waste water

Food & beverage. Oil & gas. Water & waste water Overview MSS 2100 MC1 DN 50 to DN 150 (2 to 6 ) are suitable for accurate mass flow measurement for all kind of liquids and gases. The sensor offers superior performance in terms of flow accuracy, turn-down

More information

EPS / UMF2. Magnetic Inductive Flowmeter for Conductive Liquids

EPS / UMF2. Magnetic Inductive Flowmeter for Conductive Liquids Magnetic Inductive Flowmeter for Conductive Liquids measuring monitoring analyzing EPS / UMF2 High Accuracy: 0.3 % of Actual Flow Maintenance-free No Pressure Drop Wide Variety of Lining and Electrode

More information

TEK-F LUX 1400A. Electromagnetic Flowmeter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys FLOW

TEK-F LUX 1400A. Electromagnetic Flowmeter.  Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys FLOW Technology Solutions TEK-F LUX 1400A Electromagnetic Flowmeter FLOW www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction Electromagnetic flowmeters are also

More information

SITRANS F flowmeters SITRANS F C

SITRANS F flowmeters SITRANS F C SITRNS F flowmeters Siemens G 2008 Overview is available as a standard version (DN 50 to DN 150 (2 to 6 )) and a hygienic, EHEDG certified version (DN 20 to DN 80 (¾ to 3 )). MC2 and MC2 hygienic are suitable

More information

Electromagnetic Flow Meter Owner s Manual HARDWARE

Electromagnetic Flow Meter Owner s Manual HARDWARE Electromagnetic Flow Meter Owner s Manual HARDWARE Compact Magnetic Flowmeter (Flange Connection) Sanitary Magnetic Flowmeter (Tri clamp Connection) Part No. 910000 Rev.C Content 1. GENERAL INFORMATION...2

More information

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids For use in large diameter pipes as an economical solution for flow measurement Flow rate measurement

More information

SITRANS F M. Flow sensor MAG 1100 F 3/59

SITRANS F M. Flow sensor MAG 1100 F 3/59 Overview Integration The complete flowmeter consists of a sensor and an associated transmitter MAG 5000, 6000 and 6000 I. The flexible communication concept USM II simplifies integration and update to

More information

SITRANS F flowmeters SITRANS F C SITRANS F C MC2 4/169. Overview

SITRANS F flowmeters SITRANS F C SITRANS F C MC2 4/169. Overview Siemens G 2009 SITRNS flowmeters SITRNS C SITRNS C MC2 Overview SITRNS C MC2 is available as a standard version (DN 50 to DN 150 (2 to 6 )) and a hygienic, EHEDG-certified version (DN 20 to DN (¾ to 3

More information

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M Overview The electromagnetic sensor MAG 1100 F is designed to meet applications in the food and beverage industry. Benefits sizes: 10 to 100 (/8 to 4 ) AISI 16 stainless steel enclosure : Hygienic connection,

More information

STEEMCO Flowmeter for Steam

STEEMCO Flowmeter for Steam STEEMCO Flowmeter for Steam Typical Applications The STEEMCO flow meters measure the flow of saturated and superheated steam within the process industries, including chemical, petro-chemical, pharmaceutical

More information

UniMag DT Series Electromagnetic Flow Tubes

UniMag DT Series Electromagnetic Flow Tubes Description Spirax Sarco s UniMag DT Magnetic Flow Meter System consists of the patented UniMag Flow Tube and EFT10 Flow Transmitter. UniMag sensors are unique because they do not require a liner and can

More information

ISTEC MAGNETIC METERS

ISTEC MAGNETIC METERS ISTEC MAGNETIC METERS MEASURE ANY CONDUCTIVE LIQUIDS OR SLURRIES (EVEN ABRASIVE OR CORROSIVE) WITH THE NEW MICROPROCESSOR-BASED MAGNETIC METER -- A QUALITY PRODUCT - SIMPLE - RELIABLE - AT AN AFFORDABLE

More information

STEEMCO-MAS Flowmeter for Steam

STEEMCO-MAS Flowmeter for Steam STEEMCO-MAS Flowmeter for Steam Typical Applications The STEEMCO-MAS flow meters measure the mass flow of superheated steam within the process industries, including chemical, petro-chemical, pharmaceutical

More information

The EPSILON is based on the principle of measuring velocity in the pipe line, therefore the flow measurement is volumetric.

The EPSILON is based on the principle of measuring velocity in the pipe line, therefore the flow measurement is volumetric. Typical Applications EPSILON Flowmeter The EPSILON flow meters measure the flow of most liquids and gases within the process industries, including chemical, petro-chemical, pharmaceutical and the power

More information

Flow Measurement SITRANS F C

Flow Measurement SITRANS F C Siemens G 2014 SITRNS C Overview The main applications of the Coriolis flowmeter can be found in all industries, such as: Chemical and pharma Detergents, bulk chemicals, pharmaceuticals, acids, alkalis

More information

Flow Measurement SITRANS F M. Flow sensor MAG 1100 F 4/57

Flow Measurement SITRANS F M. Flow sensor MAG 1100 F 4/57 Overview Integration The complete flowmeter consists of a sensor and an associated transmitter MAG 5000, 6000 and 6000 I. The flexible communication concept USM II simplifies integration and update to

More information

Options guide. Electromagnetic flowmeters. M9xx

Options guide. Electromagnetic flowmeters. M9xx Options guide Electromagnetic flowmeters M9xx Ordering codes Model Description M 910 -V0 0 0 0 DN50 PN16 Example Sensor M Basic Ex Ex certified (remote version only) Transmitter 910E Economic version 910

More information

Flow Measurement SITRANS F M. Flow sensor MAG /85. Overview

Flow Measurement SITRANS F M. Flow sensor MAG /85. Overview Siemens AG 2010 low Measurement Overview Design Compact or remote mounting possible Easy plug & play field changeability of transmitter Ex ATEX and M/CSA versions High temperature sensor for applications

More information

SITRANS FX300 4/289. System Overview. Overview

SITRANS FX300 4/289. System Overview. Overview Siemens G 2008 SITRNS F flowmeters Overview System Overview Version Single transmitter Dual transmitter Options Standard Pressure sensor Flange Pressure sensor and isola- Standard tion valve Sandwich vortex

More information

INSTRUCTIONS SITRANS F M MAGFLO Electromagnetic flowmeter type MAG 1100 FOOD, DN 10 - DN 100

INSTRUCTIONS SITRANS F M MAGFLO Electromagnetic flowmeter type MAG 1100 FOOD, DN 10 - DN 100 s INSTRUCTIONS SITRANS F M MAGFLO Electromagnetic flowmeter type MAG 1100 FOOD, DN 10 - DN 100 ENGLISH 083R9057 Introduction Siemens Flow Instruments SITRANS F M MAGFLO electromagnetic flowmeters consist

More information

OPTIFLUX 6000 Technical Datasheet

OPTIFLUX 6000 Technical Datasheet OPTIFLUX 6000 Technical Datasheet Electromagnetic flow sensor for hygienic and sanitary applications Robust stainless steel housing for hygienic and aseptic operation Fully suitable for CIP and SIP Typical

More information

Field IT Electro-Magnetic Flowmeters Sensors

Field IT Electro-Magnetic Flowmeters Sensors Data Sheet Field IT Electro-Magnetic Flowmeters Sensors MagMaster MFE Unrivalled flow performance ±0.2% accuracy. Pulsed DC Technology Incorporates Benefits of AC Systems Operable flow range of 1000:1.

More information

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M Overview The electromagnetic sensor MAG 1100 F is designed to meet applications in the food and beverage industry. Benefits sizes: 10 to 100 (/8 to 4 ) AISI 16 stainless steel enclosure : Hygienic connection,

More information

SITRANS F C. Flow sensor MC2 4/193. Overview

SITRANS F C. Flow sensor MC2 4/193. Overview Siemens G 2011 low Measurement SITNS C Overview The main applications of the Coriolis flowmeter can be found in all industries, such as: Chemical and pharma Detergents, bulk chemicals, pharmaceuticals,

More information

E M F. Description. Principle of Operation. Introduction for EMF Series of Electromagnetic Flowmeters

E M F. Description. Principle of Operation. Introduction for EMF Series of Electromagnetic Flowmeters EMF Series ELECTROMAGNETIC FLOWMETER Description Introduction for EMF Series of Electromagnetic Flowmeters The Electromagnetic Flowmeters(EMF) can be used to accurately measure the flowrate of liquids,

More information

F6700 ELECTROMAGNETIC METER

F6700 ELECTROMAGNETIC METER EETROMAGNETI FOW TRANSMITTER Special Features: F6700 Full Bore type Simple and ost effective onstruction Absolutely Maintenance free Suitable for all conductive liquids and slurries Outstanding Accuracy

More information

Electro-Magnetic Flowmeters Sensors MagMaster MFE

Electro-Magnetic Flowmeters Sensors MagMaster MFE Data Sheet (US) Electro-Magnetic Flowmeters Sensors MagMaster MFE Unrivalled flow performance ±0.2% accuracy. Pulsed DC Technology Incorporates Benefits of AC Systems Operable flow range of 1000:1. Two-year

More information

Flowmeter F I Gardex. Connection and installation instructions. Application. Benefits. Design and mode of operation

Flowmeter F I Gardex. Connection and installation instructions. Application. Benefits. Design and mode of operation The baffle plate (b) causes a back-pressure in the medium, and the balance beam (c) is deflected. This movement is transmitted via the beam to the indicator mechanism (e) using a bellows bushing (d). gear

More information

Flow Measurement SITRANS F C. Flow sensor MASS 2100 DI 3 to DI 40. 4/180 Siemens FI

Flow Measurement SITRANS F C. Flow sensor MASS 2100 DI 3 to DI 40. 4/180 Siemens FI Siemens AG Flow sensor MASS DI 3 to DI 0 Overview MASS DI 3 to DI 0 is suitable for accurate mass flow measurement of a variety of liquids and gases. The sensor offers superior performance in terms of

More information

EGM5300C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

EGM5300C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification MAGMAX EGM53C Compact Electromagnetic Flowmeter GENERAL MAGMAX EGM53C is a combination of EGS5 primary head with Ceramic measuring tube and high performance converter EGC3. EGM53C with high durability

More information

SITRANS P measuring instruments for pressure

SITRANS P measuring instruments for pressure Overview Application The pressure transmitter is designed for the special requirements of the food, pharmaceutical and biotechnology industries. The use of high-grade materials guarantees compliance with

More information

ABB Instrumentation. MagMaster MFE Series Electromagnetic Sensors. Specifications. MagMaster - bringing unsurpassed flowmetering performance

ABB Instrumentation. MagMaster MFE Series Electromagnetic Sensors. Specifications. MagMaster - bringing unsurpassed flowmetering performance Specifications MagMaster MFE Series Electromagnetic Sensors nn Unrivalled flow performance ±0.2% accuracy. nn Pulsed DC Technology Incorporates Benefits of AC Systems nn Operable flow range of 1000:1.

More information

ORIMAS Mass Flowmeter

ORIMAS Mass Flowmeter Typical Applications ORIMAS Mass Flowmeter The ORIMAS mass flow meters measure the mass flow of most liquids and gases within the process industries, including chemical, petro-chemical, pharmaceutical

More information

Vortex Flowmeters VFM 3100 F-T VFM 3100 W-T

Vortex Flowmeters VFM 3100 F-T VFM 3100 W-T KROHNE 10/2001 7.02313.23.00 GR/OP Vortex Flowmeters F-T W-T Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters Level measuring

More information

VersaFlow Vortex 100 Vortex Flow Meter Specifications

VersaFlow Vortex 100 Vortex Flow Meter Specifications VersaFlow Vortex 100 Vortex Flow Meter Specifications 34-VF-03-05 May 2011 The All-In-One Solution The VERSAFLOW is the only vortex flowmeter with integrated and temperature compensation in 2- wire technology.

More information

Electromagnetic Flowmeters. Product Overview.

Electromagnetic Flowmeters. Product Overview. Electromagnetic Flowmeters Product Overview www.lcmeter.com Premier products, premier performance Liquid Controls offers a broad selection of electromagnetic (Mag) flow meters for industrial and water

More information

Insertion magnetic inductive flowmeter

Insertion magnetic inductive flowmeter Insertion magnetic inductive flowmeter Sensor without moving parts Flowmeter with On/Off control Application related calibration by Teach-In function Clean in place (CIP) FDA-compliant materials Type 8041

More information

MS 2500 FLANGED SENSOR WITH A WIDE RANGE OF FLANGE SIZES. Warranty conditions are available on this website: only in English version

MS 2500 FLANGED SENSOR WITH A WIDE RANGE OF FLANGE SIZES. Warranty conditions are available on this website:   only in English version FLANGED SENSOR FLANGED SENSOR WITH A WIDE RANGE OF FLANGE SIZES Warranty conditions are available on this website: www.isomag.eu only in English version INDEX TECHNICAL DATA... 3 OVERALL FEATURES...3 STANDARD

More information

Electromagnetic flowmeters for water and seewage

Electromagnetic flowmeters for water and seewage 09/97 Electromagnetic flowmeters for water and seewage Primary head Compact flowmeters Installation instructions AQUAFLUX F 0 K 020 K 080 K CONTENTS Storage and transport Pagesn 3-4 Installation in the

More information

SITRANS F flowmeters SITRANS F I. Intra/Prima flap flowmeter. 4/284 Siemens FI

SITRANS F flowmeters SITRANS F I. Intra/Prima flap flowmeter. 4/284 Siemens FI Intra flap flowmeter for transparent liquids Prima flap flowmeter for opaque liquids pplication The flap flowmeter is used to check and display the flow of liquids in closed pipelines. The device can be

More information

Positive Displacement Flowmeters

Positive Displacement Flowmeters Positive Displacement Flowmeters SRZ series Helical screw positive displacement flowmeters Positive Displacement Flowmeters Two highly accurate cycloid-shaped screw spindles mesh and rotate inside a cylindrical

More information

Technical Data Sheet IFS 4000 KC (ENVIROMAG) Electromagnetic flowmeters. ... for water and wastewater measurements

Technical Data Sheet IFS 4000 KC (ENVIROMAG) Electromagnetic flowmeters. ... for water and wastewater measurements Technical Data Sheet KROHNE 05/2004 GR/PRINTO IFS 4000 KC (ENVIROMAG) Electromagnetic flowmeters... for water and wastewater measurements short inlet and outlet runs unaffected by contamination, solids,

More information

OPTIFLUX Electromagnetic Flow Sensor

OPTIFLUX Electromagnetic Flow Sensor OPTIFLUX 2000 Technical Datasheet Electromagnetic Flow Sensor Engineered and manufactured for the water and wastewater industry All relevant approvals for potable water Long-term reliability and durability

More information

Orifice flowmeter F O N4

Orifice flowmeter F O N4 Special features Suitable for any mounting positions without reduction in accuracy Complies with requirements for treatment and disinfection of swimming/ bathing pools (DIN 9 643) Simple installation Direct

More information

Electromagnetic flowmeters

Electromagnetic flowmeters 02/97 Electromagnetic flowmeters Primary heads Installation instructions ECOFLUX IFS 1000 F Compact flowmeters IFM 1010 K IFM 1080 K CONTENTS Installation in the pipeline Pages 4-5 and 7-8 Grounding Pages

More information

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam Metal tube flowmeters Variable area flowmeter for liquids, gases and steam Metallic or plastic tube with a robust construction Indication by means of magnetic coupling Scales calibrated in l/h, m 3 /h,

More information

FIELD DEVICES - FLOW PSS 1-6F9 A. Product Specifications

FIELD DEVICES - FLOW PSS 1-6F9 A. Product Specifications FIELD DEVICES - FLOW Product Specifications Logo 9100A Series Magnetic Flowtubes with Ebonite Liners 1 to 78 in (25 to 2000 mm) Nominal Flowtube Sizes The Foxboro brand 9100A Series Magnetic Flowtube together

More information

Magnetic float switch For vertical installation Model FLS (models with Ex approval: 60, AL-ADF)

Magnetic float switch For vertical installation Model FLS (models with Ex approval: 60, AL-ADF) Level measurement Magnetic float switch For vertical installation Model FLS (models with Ex approval: 60, AL-ADF) TC Fluid Control WIKA data sheet LM LM 3001 30.01 for further approvals see page 3 Applications

More information

BGN. All Metal Variable Area Flow Meter. Technical Data Sheet

BGN. All Metal Variable Area Flow Meter. Technical Data Sheet All Metal Variable Area Flow Meter BGN Technical Data Sheet Extremely robust through star guiding system instead of guiding rod Flow metering of liquids, gases and steam Available up to nominal size of

More information

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries Product Data Sheet January 214 813-1-475, Rev FA Rosemount 875WA Magnetic Flowmeter System For Water and Wastewater Industries THE 875WA MAGNETIC FLOWMETER Rosemount reliability in a customized offering

More information

SITRANS F X SITRANS FX300 3/355

SITRANS F X SITRANS FX300 3/355 Siemens AG 204 Flow Measurement Overview vortex flowmeters provide accurate volumetric and mass flow measurement of steam, gases and liquids as an all-in-one solution with integrated temperature and pressure

More information

The Polaris MA1 is the first liquid flow meter offered by Magnetrol, expanding the already diverse level and flow measurement portfolio that has been

The Polaris MA1 is the first liquid flow meter offered by Magnetrol, expanding the already diverse level and flow measurement portfolio that has been The Polaris MA1 is the first liquid flow meter offered by Magnetrol, expanding the already diverse level and flow measurement portfolio that has been established over the last 80 years. The electromagnetic

More information

Magnetic-Inductive Flow Meter FMQ

Magnetic-Inductive Flow Meter FMQ SENSORS FOR FOOD AND BIO. Product information FMQ FOOD Magnetic-Inductive Flow Meter FMQ Application/Specified usage Magnetic-inductive flowmeter for the measurement of flow rate and volume in food and

More information

Metal tube variable area flowmeter for gases, liquids and steam

Metal tube variable area flowmeter for gases, liquids and steam Metal tube variable area flowmeter for gases, liquids and steam Metallic or plastic tube with a robust construction Indication by means of magnetic coupling Scales calibrated in l/h, m 3 /h, kg/h, t/h,

More information

GA 24 Heavy-duty variable area flowmeter

GA 24 Heavy-duty variable area flowmeter KROHNE 10/99 D 11 GA24 01 E GR Heavy-duty variable area flowmeter Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters Level measuring

More information

Electromagnetic Flow Monitor magphant

Electromagnetic Flow Monitor magphant Technical Information TI 036D/06/en No. 50078457 Electromagnetic Flow Monitor magphant Monitoring and measurement Flow monitoring with selectable limit values (relay output) Flow measurement via 4...20

More information

Technical Information Proline Promag 10L

Technical Information Proline Promag 10L TI00100D/06/EN/1816 71326694 Products Solutions Services Technical Information Electromagnetic flowmeter The flowmeter with a weight-optimized sensor and highly cost-effectiveness Application The measuring

More information

Plastic tube variable area flowmeter for liquids and gases

Plastic tube variable area flowmeter for liquids and gases Plastic tube variable area flowmeter for liquids and gases Low cost, excellent readability and light weight Simple installation (flanged, threaded or socket ends for solvent or fusion welding connections)

More information

Flow Measurement SITRANS F M. Flow sensor MAG 5100 W. 4/68 Siemens FI Overview

Flow Measurement SITRANS F M. Flow sensor MAG 5100 W. 4/68 Siemens FI Overview Flow Measurement Siemens G 2010 Overview pplication The main applications of the electromagnetic flow sensors can be found in the following fields: Water abstraction Water treatment Water distribution

More information

VersaFlow Mag 4000 Electromagnetic Flow Sensor Technical Datasheet. Specification

VersaFlow Mag 4000 Electromagnetic Flow Sensor Technical Datasheet. Specification VersaFlow Mag 4000 Electromagnetic Flow Sensor Technical Datasheet 34-VF-03-01 September 2009 Specification Standard solution for the process industry The VersaFlow electromagnetic flow sensor is a process

More information

SENSOR MUT2300. Electromagnetic flowmeter. The electromagnetic flowmeter designed for the toughest applications DS401-1-ENG

SENSOR MUT2300. Electromagnetic flowmeter. The electromagnetic flowmeter designed for the toughest applications DS401-1-ENG SENSOR MUT2300 Electromagnetic flowmeter The electromagnetic flowmeter designed for the toughest applications DS401-1-ENG Sensor MUT2300 The MUT2300 sensors represent the state of the art of Euromag International

More information

Magnetic-Inductive flow Meter fmi

Magnetic-Inductive flow Meter fmi 1 Product information fmi-c, fmi-r f o o d P H A R M A Magnetic-Inductive flow Meter fmi Application / Specified Usage Certification Magnetic-inductive flowmeter for the measurement of flow rate and volume

More information

OPTISWIRL 4070 Technical Datasheet

OPTISWIRL 4070 Technical Datasheet OPTISWIRL 4070 Technical Datasheet Vortex flowmeter Integrated pressure and temperature compensation Temperature compensation for saturated steam included as standard All OPTISWIRL versions in 2-wire technology

More information

WATERFLUX 3000 Technical Datasheet

WATERFLUX 3000 Technical Datasheet WATERFLUX 3000 Technical Datasheet Electromagnetic flowmeter Easy installation without straight inlet or outlet lengths For installation in small spaces Wide range of approvals for potable water The documentation

More information

Cleanfit CPA471. Technical Information. Compact retractable assembly for installation of ph, ORP electrodes in tanks or pipelines

Cleanfit CPA471. Technical Information. Compact retractable assembly for installation of ph, ORP electrodes in tanks or pipelines Technical Information Cleanfit CPA471 Compact retractable assembly for installation of ph, ORP electrodes in tanks or pipelines Application Chemical industry Wastewater treatment Plant design Tanks and

More information

PMG MAGNETIC FLOWMETER

PMG MAGNETIC FLOWMETER PMG MAGNETIC FLOWMETER Flow Pressure Level Temperature measurement monitoring control Flow Ranges 0.015-0.5 Through 350-10600 GPM 1/2 to 12 Sizes Accuracy ±0.5% or ±0.25% of Reading Viscosity and Density

More information

Electromagnetic flowmeter EMKO E

Electromagnetic flowmeter EMKO E Electromagnetic flowmeter EMKO E - Quality design - High corrosion resistance - Reliable measurement principle Doc. no.: 70, en_cat_emkoe, 8/2015 Description Electromagnetic Flowmeter EMKO E consists of

More information

Flow Measurement SITRANS F X SITRANS FX300 4/365

Flow Measurement SITRANS F X SITRANS FX300 4/365 Siemens AG 200 Overview vortex flowmeters provide accurate volumetric and mass flow measurement of steam, gases and liquids as an all-in-one solution with integrated temperature and pressure compensation.

More information

Satellite photo of cloud vortices caused by a mountain (Courtesy of our friends at NASA) tekvorx Operation Showing Simplified Construction

Satellite photo of cloud vortices caused by a mountain (Courtesy of our friends at NASA) tekvorx Operation Showing Simplified Construction Sensing the pulse of industry tekvorx TV01 Multivariable Vortex flow Sensors Vortex flow sensors derive their name from a natural phenomenon of fluid dynamics. When a gas or relatively low viscosity liquid

More information

Volumeter TRZ 03-K PRODUCT INFORMATION. Reliable Measurements of Gas

Volumeter TRZ 03-K PRODUCT INFORMATION. Reliable Measurements of Gas Volumeter TRZ 0-K PRODUCT INFORMATION Reliable Measurements of Gas Method of operation, Construction Method of operation The TRZ 0-K Volumeter is a flow meter suitable for metering gases, where the rate

More information

EGM1100C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

EGM1100C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification EGMC Compact Electromagnetic Flowmeter GENERA MAGMAX EGMC is the compact type electromagnetic flowmeter with a converter EGC mounted integrally on a primary head EGS lined with fluorocarbon resin PFA.

More information

KDM ARMORED FLOW METER & SWITCH

KDM ARMORED FLOW METER & SWITCH KDM ARMORED FLOW METER & SWITCH Flow Pressure Level Temperature measurement monitoring control S2 Short Installation Length SS, PTFE or Hastelloy Wetted Parts Analog Output Available 110 F to + 390 F Temperature

More information

Magnetic-Inductive Flow Meter FMI

Magnetic-Inductive Flow Meter FMI SENSORS FOR FOOD AND BIO. Product information FMI-C, FMI-R FOOD Magnetic-Inductive Flow Meter FMI Application/Specified usage Magnetic-inductive flowmeter for the measurement of flow rate and volume in

More information

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1 INLINE Flow sensor for hazardous area II G/D - II D - II GD - I M Type SE0 Ex can be combined with... Flow meter with NAMUR or NPN/PNP output signal Mounting, dismounting of electronics by a Quarter-Turn

More information

9300A Series Flanged Magnetic Flowtubes

9300A Series Flanged Magnetic Flowtubes Product Specifications 9300A Series Flanged Magnetic Flowtubes pfa Lined, 1 through 12 Inch; ptfe Lined, 1/2 through 16 Inch; Polyurethane Lined, 8 through 16 Inch PSS 1-6F4 A FEATURES pfa Withstands Effects

More information

Electromagnetic amplifier type ModMAG M10 for all detectors

Electromagnetic amplifier type ModMAG M10 for all detectors Badger Meter Europa GmbH Nürtinger Str. 76 72639 Neuffen (Germany) Tel. +49-7025-9208-0 Fax +49-7025-9208-15 www.badgermeter.de badger@badgermeter.de Electromagnetic amplifier type ModMG M10 for all detectors

More information

PROCESSAUTOMATIC MAGNETIC FLOWMETER

PROCESSAUTOMATIC MAGNETIC FLOWMETER PROCESSAUTOMATIC MAGNETIC FLOWMETER SWEDEN The PROCESSAUTOMATIC magnetic flowmeter is suitable for most hygienic applications as all wetted parts are made of food grade stainless steel or teflon and most

More information

Volumeter. RMG Meßtechnik GmbH. Publication No E

Volumeter. RMG Meßtechnik GmbH. Publication No E Volumeter TRZ 03-K RMG Meßtechnik GmbH Publication No. 3.171-E P.O.Box 80 D-3550 Butzbach (Germany) Phone: +49 (0)6033 897-0 Fax: +49 (0)6033 897-130 E-mail: messtechnik@rmg.de Web site: http://www.rmg.de

More information

Design and application

Design and application Design and application The function of the SGM is based on the variable area float principle. In all cases where a dependable device is required for indicating instantaneous values and monitoring the flow

More information

JUMO flowtrans MAG Series. Electromagnetic flowmeters for the process industry and for hygienic applications

JUMO flowtrans MAG Series. Electromagnetic flowmeters for the process industry and for hygienic applications JUMO flowtrans MAG Series Electromagnetic flowmeters for the process industry and for hygienic applications Contact Phone: +49 661 6003-715 Email: sensors@jumo.net Dear Reader, Until now, JUMO has relied

More information

SITRANS P measuring instruments for pressure

SITRANS P measuring instruments for pressure Overview Siemens AG 009 Supplementary electronics for 4-wire connection Design Dimensions (W x H x D) in mm (inch) Electrical connection 80 x 10 x 60 (3.15 x 4.7 x.36) Screw terminals (Pg 13.5 cable inlet)

More information

Electromagnetic amplifier Primo Advanced for all detectors

Electromagnetic amplifier Primo Advanced for all detectors Electromagnetic amplifier Primo dvanced for all detectors Features ccuracy ±0,25% Flow range 0,03 12 m/s 6 2000 LC display Power supply 85 2 VC / 24 VC escription imensions The amplifier type Primo dvanced

More information

SITRANS F C MASSFLO Practical examples of ordering. MASS2100 & MASS6000 IP67 Compact mounted

SITRANS F C MASSFLO Practical examples of ordering. MASS2100 & MASS6000 IP67 Compact mounted SITRNS F C MSSFLO MSS2100 & MSS6000 IP67 Compact mounted Mass 2100 sensor DI 3 - DI 40 MSS 6000 IP67 transmitter. Use ordering code FI 01 Catalogue p. 4/140 MSS system: 7ME4100-2EC21-2D1 FI 01 catalogue

More information

Datasheet MATRE Foam Inductors. Datasheet for MATRE Foam Inductors. 1 Contents

Datasheet MATRE Foam Inductors. Datasheet for MATRE Foam Inductors. 1 Contents Datasheet for MATRE Foam Inductors 1 Contents 2 General product description... 3 3 General installation guide... 3 4 Product dimensions and performance... 3 4.1 Standard bronze housing design - threaded...4

More information

Proline Promag 10L. Technical Information. Electromagnetic Flow Measuring System Flow measurement of liquids in water or wastewater applications

Proline Promag 10L. Technical Information. Electromagnetic Flow Measuring System Flow measurement of liquids in water or wastewater applications Technical Information Proline Promag 10L Electromagnetic Flow Measuring System Flow measurement of liquids in water or wastewater applications Application Electromagnetic flowmeter for bidirectional measurement

More information

ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products Rev PK KMS501W & KMS502F- TW. Electromagnetic TRADEWASTE Flowmeters FEATURES:

ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products Rev PK KMS501W & KMS502F- TW. Electromagnetic TRADEWASTE Flowmeters FEATURES: KMS501W & KMS502F- TW FEATURES: Fitted with Sydney Water Tradewaste plugs (Sampler and ma outputs). For waste water, bore water and irrigation ( upto 10% solids). Unsurpassed accuracy to ±0.5% 0.5 m/s

More information

SENSOR MUT2200EL. Electromagnetic flowmeter. The electromagnetic flowmeter for all applications DS100-6-ENG

SENSOR MUT2200EL. Electromagnetic flowmeter. The electromagnetic flowmeter for all applications DS100-6-ENG SENSOR MUT2200EL Electromagnetic flowmeter The electromagnetic flowmeter for all applications DS100-6-ENG Sensor MUT2200EL MUT2200EL sensors represent the state of the art of Euromag International production

More information

JUMO dtrans p20 DELTA

JUMO dtrans p20 DELTA Data Sheet 403022 Page 1/9 JUMO dtrans p20 DELTA Differential pressure transmitter Brief description The JUMO dtrans p20 DELTA differential pressure transmitter with HART interface combines maximum precision

More information

Smart Electromagnetic Flowmeter Detector for Sanitary use

Smart Electromagnetic Flowmeter Detector for Sanitary use MagneW3000 PLUS Smart Electromagnetic Flowmeter Detector for Sanitary use Model MGS28U OVERVIEW The MagneW3000 PLUS Smart Electromagnetic Flowmeter for Sanitary use is a high-performance and highly-reliable

More information

SENSOR MUT2300. Electromagnetic flowmeter. The electromagnetic flowmeter designed for the toughest applications DS401-1-USA

SENSOR MUT2300. Electromagnetic flowmeter. The electromagnetic flowmeter designed for the toughest applications DS401-1-USA SENSOR MUT2300 Electromagnetic flowmeter The electromagnetic flowmeter designed for the toughest applications DS401-1-USA Sensor MUT2300 The MUT2300 sensors represent the state of the art of Euromag International

More information

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd Pointek CLS200 Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level switch with optional rod/cable choices liquids, solids,

More information

DMP 331P DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

DMP 331P DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm DMP P Industrial Pressure Transmitter Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Industrial

More information

Variable area flowmeter H 250

Variable area flowmeter H 250 KROHNE 10/99 D 11 H250 01 E GR Variable area flowmeter Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters Level measuring instruments

More information