SITRANS F X SITRANS FX300 3/355

Size: px
Start display at page:

Download "SITRANS F X SITRANS FX300 3/355"

Transcription

1 Siemens AG 204 Flow Measurement Overview vortex flowmeters provide accurate volumetric and mass flow measurement of steam, gases and liquids as an all-in-one solution with integrated temperature and pressure compensation. SITRANS FX00 The main applications of SITRANS FX00 can be found in the following sectors: Chemical Petrochemical Oil & Gas Power plants -Air - Heating - Cooling - Chilling Food & beverage - Pharmaceutical - Sugar refineries - Dairies -Breweries - Production of soft drinks Refining Water & waste water System Overview Version Flange Sandwich Dual transmitter Compact Benefits All devices have 2-wire technology and HART communication Temperature compensation for saturated steam as standard feature Integrated temperature and pressure measurement enabling direct compensation of density Pressure, temperature and flow can be read at a single point. No additional installation of pressure and temperature sensors Direct measurement of energy or energy consumption Optimum process reliability thanks to Intelligent Signal Processing (ISP) - stable readings, free of external perturbations Fully welded stainless steel construction with high corrosion, pressure and temperature resistance Maintenance-free sensor design Ready to use due to plug & play feature. No additional cabling work Minimal pressure drop Compact or remote design Pressure and temperature compensation for fluctuating volume flows Measurement of consumption in compressed air systems No risk of deposits or damage (sensor in the turbulent area) All units parameterized prior to delivery Application The SITRANS FX00 is a flowmeter in a single or dual transmitter version, suitable for measuring industrial steam, gases, as well as conductive and non-conductive liquids, e.g. steam (saturated steam, superheated steam), industrial gases (compressed air, nitrogen, liquefied gases, flue gases), and conductive and non-conductive liquids (demineralized water, boiler feed water, solvents, heat transfer oil). Remote Design The unit is available in a compact or a remote version with up to 5 meter distance from flowmeter to transmitter. When ordering a remote version the transducer cables are pre-mounted and ready for installation. Function Operating Principle vortex flowmeters measure flow rate by detecting the frequency at which alternating vortices are shed from a bluff body inserted into the flow stream. This principle of measurement is known as Von Karman s vortex street principle: alternating vortices form behind an object in a stream. The frequency of the alternating vortices is proportional to the flow rate. The passage of a vortex causes a slight stress on a pick-up placed downstream of the bluff body. The stress is picked up and counted as pressure surges by a dual Piezo crystal placed inside the wing. Siemens FI US Edition /55

2 Flow Measurement Siemens AG 204 SITRANS FX00 Q d $ = Bluff Body, % = Pick-up The flowmeter calculates the flow velocity using the following equation: Q = A V = A d / St f = 0.9 f / K [m /h] Where: Q = flow rate [m /h] f = vortex shedding frequency [Hz] K = calibration constant [pulses/m ] d = width of the bluff body [m] St = Strouhal Number A = cross-section area [m 2 ] V = flow velocity [m/s] Requirements In order to generate the vortex streets, the medium must have a minimum velocity: For steam and gases, the flow velocity must be 2 to 80 m/s (6.6 to 262 ft/s) For liquids the flow velocity must be 0.4 to 0 m/s (. to 2.8 ft/s) Design SITRANS FX00 volumetric and mass flowmeter is available in the following configurations: SITRANS FX00 Single transmitter The single transmitter is available as a flange or sandwich solution in the following versions: Vortex standard flowmeter Measurement with integrated temperature sensor as standard feature Vortex flowmeter with pressure sensor Measurement with integrated temperature and pressure sensors for compensation of gases, wet gases, gas mixtures or steam (for engergy measurement). Vortex flowmeter with pressure sensor and isolation valve Allowing the pressure sensor to be shut off for the purpose of pressure or leak testing of the pipeline or for being exchanged without interrupting the process. Using the built-in two-way valve, the pressure sensor can also be calibrated and tested at a later time. Vortex flowmeter - remote version Sensors and tranmitters mounted separately. The device is equipped with temperature sensor (standard), pressure sensor (optional) and isolation valve (optional) providing all the features of the compact mounted version. SITRANS FX00 Dual transmitter This is a genuine redundant system with two independent sensors and two transmitters providing twofold functional reliability and availability of the measurement. This variant is optimally suited for measurements in multi-product pipelines. The dual converter is available as: Vortex standard flowmeter Measurement with temperature sensor for saturated steam compensation as standard feature 2 Technical specifications Input Measuring range limits See Dimensional Drawings Media pressure bar ( psi) (Higher pressures on request) Output Current output Measuring range 4 20 ma Over range 20.8 ma % (05% %) Load -min. 00 -max. R max = (U Power Supply - 4 V)/22 ma Error signal NAMUR NE 4 Maximum output 22 ma (2.5 %) Multidrop mode 4 ma Digital output Communication HART Physical layer FSK Device category Transmitter Pulse output (Passive pulse output, needs separate power supply. Pulse output has to be defined in the Option menu Y47 totalizer or energy unit has to be entered. E.g.: pulse/kg or pulse/0 m³) Pulse frequency Max. 0.5 Hz Power supply Min. 24 V DC as NAMUR or Non-Ex version open < ma, max. 6 V, closed 00 ma, U < 2 V Ex version open < ma, max. 0 V, closed 00 ma, U < 2 V Accuracy Standard version For liquids -Re % For steam and gases -Re % For steam, gases and liquids < Re < % Pressure and temperaturecompensated version For liquids < Re < % -Re % For gases and steam < Re < % -Re % Repeatability 0. % Installation conditions (At different conditions, e.g. installation after control valve, bends or reductions, please refer to the operating instructions.) Inlet run 20 x DN Outlet run 5 x DN /56 Siemens FI US Edition

3 Siemens AG 204 Flow Measurement Software Uncompensated for gases, steam and liquids, but temperature-compensated for saturated steam Density-compensated by temperature and pressure for superheated steam, no energy calculation Gross heat When the thermal energy of steam is to be measured In options Y5 to Y56 add information regarding: Order option Order option 4 Order option 5 Y5 Variable current output Y52 Power unit Select one of the following units from power units table in Y52: kj/h, MJ/h, GJ/h, Btu/h, kcal/h, kw, MW or special (custom) Y5 Fullscale power value Y54 Variable pulse output Y55 Totalizer on/off Y56 Configures for totalizer select one of the following units from energy units table in Y56: kj, MJ, GJ, Btu th, kcal, kwh, MWh or special (custom). Density compensated by temperature and pressure for gases, wet Order option 7 gases Wet gases Select Y49 and enter relative humidity in % FAD - Free Air Delivery When the delivered air of a compressor is to be Order option 8 measured In Y8 to Y87 add information regarding: Mixed gases Y8 Inlet suction temperature Y82 Atmosphere pressure Y8 Pressure drop at inlet filter Y84 Inlet relative humidity Y85 Actual revolutions per minute (of compressor) Y86 Rated rpm of compressor Y87 Outlet relative humidity. This information is available from compressor supplier. When the fluid is a gas mixture, contact your local Siemens representative and provide gas names and amount in %. Rated operation conditions Ambient temperature Non-Ex version C( F) Ex version C( F) Storage temperature C( F) Media temperature C ( F) Density Taken into consideration when rating Viscosity <0 cp Reynolds number Media pressure limit Max. 00 bar (450 psi) Higher pressure on request (contact your local Siemens representative) SITRANS FX00 Design Material Sensor: house/pick-up AISI 6L (.4404)/ AISI 6L (.445) Hastelloy C22/ available on request (contact your local Siemens representative) Housing: transmitter Aluminum for increased requirements Sensor gaskets (Pick-up/Pressure sensor) AISI 6L (.445) / FPM or FFKM FPM (Viton) for steam and non-aggressive gases. FFKM (Kalrez) for chlorine and other aggressive gases. (FPM/FFKM gaskets are only supplied if FX00 is configured with pressure sensor) Process connections Flange norm EN 092- form B/B2 or ASME B6.5 RF. Other flanges on request (contact your local Siemens representative) Flange version DN5 00 (½ 2") Sandwich version DN5 00 (½ 4") Degree of protection IP66/IP67 Dimensions and weights See Dimensional Drawings Display and operating interface Local display 2 lines, 0 characters per line Languages German, English, French Power supply Standard version 4 6 V DC Ex version 4 0 V DC Certificates and approvals Explosion protection ATEX II 2G EEx d ia [ia] IIC T6 FM US/C Class I, II, III, Div. and 2 Calibration All flowmeters will be delivered with a point calibration certificate Material Certificate Certificate of compliance, pressure test, material certificate, material in acc. of NACE and PMI of pressure bearing metal parts. Cleaning Choose Cleaning Class when fluid is oxygen or contains chloride. Certificates X-ray test on pressurized weldings and dye penetration test on pressure bearing weldings Dye penetration test Siemens FI US Edition /57

4 Flow Measurement Siemens AG 204 SITRANS FX00 Selection and Ordering data Article No. Ord. code SITRANS FX00 Flanged 7ME2600- Single transmitter and T max = 240 C (464 F) Connection size Sensor size DN 5 (½") DN 5 A DN 25 (") DN 25 2B DN 40 (½") DN 40 2K DN 50 (2") DN 50 2R DN 80 (") DN 80 L DN 00 (4") DN 00 S DN 50 (6") DN 50 4M DN 200 (8") DN 200 4T DN 250 (0") DN 250 4W DN 00 (2") DN 00 5E Flange norm and nominal pressure Form B/B2 EN 092- PN 0 DN A PN 6 DN B PN 25 DN C PN 40 DN D PN 6 DN E PN 00 DN F RF ASME B lb ½... 2" J 00 lb ½... 2" K 600 lb ½... 6" L Sensor material/gasket St. steel AISI 6L (.4404)/AISI 6L (.445)/ FPM St. steel AISI 6L (.4404)/AISI 6L 5 (.445)/ FFKM Transmitter design Compact version - no cable Remote version: 5 m (6.4 ft) 2 0 m (2.8 ft) 5 m (49.2 ft) 4 Approval and cable gland Non-Ex, M20 x.5 Non-Ex, ½ NPT 2 FM approval Class Div. 2, M20 x.5 ATEX, M20 x.5 4 ATEX, ½ NPT 5 FM approval Class Div., M20 x.5 6 FM approval Class Div., /2" NPT 7 FM approval Class Div. 2, /2" NPT 8 Further approvals and cable glands IEC Ex with M20 x.5 9 N 0 A IEC Ex with ½" NPT 9 N 0 B Transmitter, display and communication With display, HART A Selection and Ordering data Article No. Ord. code SITRANS FX00 Flanged 7ME2600- Single transmitter and T max = 240 C (464 F) Pressure sensor and isolation valve Without pressure sensor A With pressure sensor, range: 4 bar (58 psi) B 6 bar (87 psi) D 0 bar (45 psi) E 6 bar (22 psi) G 25 bar (6 psi) H 40 bar (580 psi) K 60 bar (870 psi) L 00 bar (450 psi) N With isolation valve and pressure sensor, range: 4 bar (58 psi) P 6 bar (87 psi) Q 0 bar (45 psi) R 6 bar (22 psi) S 25 bar (6 psi) U 40 bar (580 psi) V 60 bar (870 psi) W 00 bar (450 psi) Y Software Uncompensated for gases, wet gases, steam and liquids, respectively, temperature compensation for saturated steam Density compensation for superheated 4 steam Density compensation for superheated 5 steam and setting of Gross heat Opt. Y5... Y56 for Energy measuring Density compensation for gases and wet 7 gases and setting of Relative humidity at opt. Y49 Density compensation for gases, wet gases 8 and setting of FAD - free air delivery Opt. Y49 and Y8... Y87 for Compressor settings /58 Siemens FI US Edition

5 Siemens AG 204 Flow Measurement Selection and Ordering data Additional information Please add -Z to Article No. and specify as minimum Order code Y40, Y4, Y42 and Y45 and plain text. Input process data Medium: Specify steam, gas, liquid or customised Temperature: Specify max. operating temperature and units Pressure: Specify max. operating pressure and units Density (only by customer-specified medium): Specify medium density and units Viscosity (only by customer-specified medium): Specify medium viscosity and units Flow rate: Specify min./max. flow rate and units Setting of pulse output: Specify totalizer or energy unit ( pulse/unit) Relative humidity (amount in % of process medium) Settings of gross heat Variable current output Power unit (specify: kj/h, MJ/h, GJ/h, Btu/h, kcal/h, kw, MW or special (custom)) Fullscale power value Variable pulse output Totalizer on/off Configure totalizer (specify: kj, MJ, GJ, Btu th, kcal, kwh, MWh or special (custom)) Settings of FAD Inlet suction temperature ) Atmosphere pressure ) Pressure drop filter 2) Inlet relative humidity ) Actual revolutions per minute (of compressor) 2) Rated Rpm of compressor 2) Outlet relative humidity 2) Order code Y40 Y4 Y42 Y4 Y44 Y45 Y47 Y49 Y5 Y52 Y5 Y54 Y55 Y56 Y8 Y82 Y8 Y84 Y85 Y86 Y87 ) Information to be provided by customer. 2) Information is available on the data sheet from the compressor supplier. Operating instructions Description English Article No. A5E20042 SITRANS FX00 This device is shipped with a Quick Start guide and a CD containing further SITRANS F literature. All literature is also available for free at: Selection and Ordering data Further designs Please add -Z to Article No. and specify Order code. Converter housing material Aluminum for increased requirement, color: petrol green Material certificate Certificate of compliance EN Pressure test +. accordance EN 0204 Material certificate pressure parts + certificate. Material in accordance with NACE MR PMI of pressure bearing metal parts + certificate. Material certificate pressure parts + PMI/certificate. Calibration certificate FX00 As standard the flow device has a -point calibration certificate. Calibration certificate (5 point) Hardness test Hardness test on pressure bearing parts +. Equotip LD procedure according to NACE MR Cleaning for oil and fat Class increased requirement (customer-specified) and. (EN 0204) Class 2 and. (EN 0204) Certificates X-ray test on pressure bearing weldings Dye penetration test on pressure bearing weldings Tag name plate Stainless steel tag with mm characters, max. 2 x 8 characters (40 x 20 mm, add plain text) Stainless steel tag with 2.5 mm characters, max. 8 x 40 characters (20 x 46 mm, add plain text) Order code A0 C0 C C2 C C4 C5 D H0 K46 K48 M56 M58 Y7 Y8 Siemens FI US Edition /59

6 Flow Measurement Siemens AG 204 SITRANS FX00 Selection and Ordering data Article No. Ord. code SITRANS FX00 Sandwich Single transmitter and 7ME2700- T max = 240 C (464 F) Connection size Sensor size DN 5 (½") DN 5 A DN 25 (") DN 25 2B DN 40 (½") DN 40 2K DN 50 (2") DN 50 2R DN 80 (") DN 80 L DN 00 (4") DN 00 S Nominal pressure EN PN 6 DN B PN 40 DN D PN 6 DN E PN 00 DN F ASME 50 lb ½... 4" J 00 lb ½... 4" K 600 lb ½... 4" L Sensor material/gasket St. steel AISI 6L (.4404)/AISI 6L (.445)/FPM St. steel AISI 6L (.4404)/AISI 6L 5 (.445)/FFKM Transmitter design Compact version - no cable Remote version: 5 m (6.4 ft) 2 0 m (2.8 ft) 5 m (49.2 ft) 4 Approval and cable gland Non-Ex, M20 x.5 Non-Ex, ½ NPT 2 FM approval Class Div. 2, M20 x.5 ATEX, M20 x.5 4 ATEX, ½ NPT 5 FM approval Class Div., M20 x.5 6 FM approval Class Div., /2" NPT 7 FM approval Class Div. 2, /2" NPT 8 Further approvals and cable glands IEC Ex with M20 x.5 9 N 0 A IEC Ex with ½" NPT 9 N 0 B Transmitter, display and communication With display, HART A Selection and Ordering data Article No. Ord. code SITRANS FX00 Sandwich Single transmitter and 7ME2700- T max = 240 C (464 F) Pressure sensor and isolation valve Without pressure sensor A With pressure sensor, range: 4 bar (58 psi) B 6 bar (87 psi) D 0 bar (45 psi) E 6 bar (22 psi) G 25 bar (6 psi) H 40 bar (580 psi) K 60 bar (870 psi) L 00 bar (450 psi) N With isolation valve and pressure sensor, range: 4 bar (58 psi) P 6 bar (87 psi) Q 0 bar (45 psi) R 6 bar (22 psi) S 25 bar (6 psi) U 40 bar (580 psi) V 60 bar (870 psi) W 00 bar (450 psi) Y Software Uncompensated for gases, wet gases, steam and liquids respectively temperature compensation for saturated steam Density compensation for superheated steam 4 Density compensation for superheated steam 5 and setting of Gross heat Opt. Y5... Y56 for Energy measuring Density compensation for gases and wet 7 gases and setting of Relative humidity at opt. Y49 Density compensation for gases, wet gases 8 and setting of FAD - free air delivery Opt. Y49 and Y8... Y87 for Compressor settings /60 Siemens FI US Edition

7 Siemens AG 204 Flow Measurement Selection and Ordering data Additional information Please add -Z to Article No. and specify as minimum Order code Y40, Y4, Y42 and Y45 and plain text. Input process data Medium: Specify steam, gas, liquid and customised Temperature: Specify max. operating temperature and units Pressure: Specify max. operating pressure and units Density (only by customer-specified medium): Specify medium density and units Viscosity (only by customer-specified medium): Specify medium viscosity and units Flow rate: Specify min./max. flow rate and units Setting of pulse output: Specify totalizer or energy unit ( pulse/unit) Relative humidity (amount in % of process medium) Settings of gross heat Variable current output Power unit (specify: kj/h, MJ/h, GJ/h, Btu/h, kcal/h, kw, MW or special (custom)) Fullscale power value Variable pulse output Totalizer on/off Configure totalizer (specify: kj, MJ, GJ, Btu th, kcal, kwh, MWh or special (custom)) Settings of FAD Inlet suction temperature ) Atmosphere pressure ) Pressure drop filter 2) Inlet relative humidity ) Actual revolutions per minute (of compressor) 2) Rated Rpm of compressor 2) Outlet relative humidity 2) Order code Y40 Y4 Y42 Y4 Y44 Y45 Y47 Y49 Y5 Y52 Y5 Y54 Y55 Y56 Y8 Y82 Y8 Y84 Y85 Y86 Y87 ) Information to be provided by customer. 2) Information is available on the data sheet from the compressor supplier. Operating instructions Description English Article No. A5E20042 SITRANS FX00 This device is shipped with a Quick Start guide and a CD containing further SITRANS F literature. All literature is also available for free at: Selection and Ordering data Further designs Please add -Z to Article No. and specify Order code. Converter housing material Aluminum for increased requirement, color: petrol green Material certificate Certificate of compliance EN Pressure test +. accordance EN 0204 Material certificate pressure parts + certificate. Material in accordance with NACE MR PMI of pressure bearing metal parts + certificate. Material certificate pressure parts + PMI/certificate. Calibration certificate FX00 As standard the flow device has a -point calibration certificate. Calibration certificate (5-point) Hardness test Hardness test on pressure bearing parts +. Equotip LD procedure according to NACE MR Cleaning for oil and fat Class increased requirement (customer-specified) and. (EN 0204) Class 2 and. (EN 0204) Certificates X-ray test on pressure bearing weldings Dye penetration test on pressure bearing weldings Tag name plate Stainless steel tag with mm characters, max. 2 x 8 characters (40 x 20 mm, add plain text) Stainless steel tag with 2.5 mm characters, max. 8 x 40 characters (20 x 46 mm, add plain text) Order code A0 C0 C C2 C C4 C5 D H0 K46 K48 M56 M58 Y7 Y8 Siemens FI US Edition /6

8 Flow Measurement Siemens AG 204 SITRANS FX00 Selection and Ordering data Article No. Ord. code SITRANS FX00 Flanged Dual transmitter and 7ME2800- T max = 240 C (464 F) Connection size Sensor size DN 40 (½") DN 40 2K DN 50 (2") DN 50 2R DN 80 (") DN 80 L DN 00 (4") DN 00 S DN 50 (6") DN 50 4M DN 200 (8") DN 200 4T DN 250 (0") DN 250 4W DN 00 (2") DN 00 5E Flange norm and nominal pressure Form B/B2 EN 092- PN 0 DN A PN 6 DN B PN 25 DN C PN 40 DN D PN 6 DN E PN 00 DN F RF ASME B lb ½... 2" J 00 lb ½... 2" K 600 lb ½... 6" L Sensor material/gasket Stainless steel AISI 6L (.4404)/ AISI 6L (.445)/FPM Stainless steel AISI 6L (.4404)/ 5 AISI 6L (.445)/FFKM Transmitter design Compact version - no cable Remote version: 5 m (6.4 ft) 2 0 m (2.8 ft) 5 m (49.2 ft) 4 Approval and cable gland Non-Ex, M20 x.5 Non-Ex, ½ NPT 2 FM approval Class Div. 2, M20 x.5 ATEX, M20 x.5 4 ATEX, ½ NPT 5 FM approval Class Div., M20 x.5 6 FM approval Class Div., /2" NPT 7 FM approval Class Div. 2, /2" NPT 8 Further approvals and cable glands IEC Ex with M20 x.5 9 N 0 A IEC Ex with ½" NPT 9 N 0 B Transmitter, display and communication With display, HART A Pressure sensor and isolation valve Without pressure sensor A Software Uncompensated for gases, wet gases, steam and liquids respectively temperature compensation for saturated steam Selection and Ordering data Additional information Please add -Z to Article No. and specify as minimum Order code Y40, Y4, Y42 and Y45 and plain text. Input process data Medium: Specify steam, gas, liquid and customised Temperature: Specify max. operating temperature and units Pressure: Specify max. operating pressure and units Density (only by customer-specified medium): Specify medium density and units Viscosity (only by customer-specified medium): Specify medium viscosity and units Flow rate: Specify min./max. flow rate and units Setting of pulse output; Specify totalizer or energy unit ( pulse/unit) Relative humidity (amount in % of process medium) Operating instructions for SITRANS FX00 Description Article No. English A5E20042 Order code Y40 Y4 Y42 Y4 Y44 Y45 Y47 Y49 This device is shipped with a Quick Start guide and a CD containing further SITRANS F literature. All literature is also available for free at: Selection and Ordering data Further designs Please add -Z to Article No. and specify Order code. Converter housing material Aluminum for increased requirement, color: petrol green Material certificate Certificate of compliance EN Pressure test +. accordance EN 0204 Material certificate pressure parts + certificate. Material in accordance with NACE MR PMI of pressure bearing metal parts + certificate. Material certificate pressure parts + PMI/certificate. Calibration certificate FX00 As standard the flow device has a -point calibration certificate. Calibration certificate (5-point) Hardness test Hardness test on pressure bearing parts +. Equotip LD procedure according to NACE MR Cleaning for oil and fat Class increased requirement (customer-specified) and. (EN 0204) Class 2 and. (EN 0204) Certificates X-ray test on pressure bearing weldings Dye penetration test on pressure bearing weldings Tag name plate Stainless steel tag with mm characters, max. 2 x 8 characters (40 x 20 mm, add plain text) Stainless steel tag with 2.5 mm characters, max. 8 x 40 characters (20 x 46 mm, add plain text) Order code A0 C0 C C2 C C4 C5 D H0 K46 K48 M56 M58 Y7 Y8 /62 Siemens FI US Edition

9 Siemens AG 204 Flow Measurement SITRANS FX00 SITRANS FX00 spare parts Description Article No. Seal disc A5E02849 Socket only for DN 5/25 ; /2" Socket only for DN 5/25 ; " Pickup AISI 6L/.4404 On request On request On request O-ring pickup A5E Description Service Toolbox for programming the software (basic, steam and gas) as well as for changing settings and parameters. Note: Dedicated service training is required. Please contact Customer Support. Article No. A5E O-ring for pressure screw A5E x 2.62-FPM-70 Pressure sensor On request 4/6/0/6/25/40/60/00 bar Cover gasket O-Ring A5E x.5 Converter housing gasket A5E ,5,5-2-N O-ring DIN77-20 x -FPM for A5E02855 sensor O-ring 0x2-NBR for leadthrough A5E DUBOX plug, 5-pole-RM2 A5E Electronic Basic D-HART A5E0285 Schematics 2 2 Power supply Load - + ma Ampere meter, optional HART A A+ B B+ Steam D-HART Gas D-HART A5E02854 A5E Load for HART communication HART Display Cable feedthrough 0-pole (non-ex). O-ring for cable feedthrough 2.89 x pole plug Sensor replacement (incl. Seal disc, pickup, O-rings for pickup, and pressure screw DN 5 (incl. ½" socket) A5E A5E A5E Power supply Load Connection pulse output ma Ampere meter, optional 4 Counter A A+ B B+ DN 25 (incl. " socket) A5E0286 DN A5E02852 DN A5E Pressure sensor replacement (Incl. pressure sensor, DUBOX plug, 2 O-rings and calibration certificate) 4 bar (58 psi) A5E bar (87 psi) A5E bar (45 psi) A5E bar (22 psi) A5E bar (6 psi) A5E bar (580 psi) A5E bar (870 psi) A5E bar (450 psi) A5E02847 Siemens FI US Edition /6

10 Flow Measurement Siemens AG 204 SITRANS FX00 Dimensional drawings Compact version a c b a c b D H H l L d Flange version Flange version with pressure sensor a D H D L d L H Flange version, dual converter /64 Siemens FI US Edition

11 Siemens AG 204 Flow Measurement SITRANS FX00 Flange version EN092- Size Pressure rating Dimensions [mm (inch)] Weight [kg (lb)] ) DN PN a b c d D L H l Flowmeter (without pressure sensor) Flowmeter (with pressure sensor) 5 40 (5.24) 05 (4.) 79 (7.05) 7. (0.68) 95 (.74) 200 (7.87) 265 (0.4) 44 (5.67) 5.5 (2.) 6. (.45) 5 00 (5.24) 05 (4.) 79 (7.05) 7. (0.68) 05 (4.) 200 (7.87) 265 (0.4) 44 (5.67) 6.5 (4.) 7. (5.65) (5.24) 05 (4.) 79 (7.05) 28.5 (.2) 5 (4.5) 200 (7.87) 265 (0.4) 44 (5.67) 7. (6.09) 7.9 (7.42) (5.24) 05 (4.) 79 (7.05) 28.5 (.2) 40 (5.5) 200 (7.87) 265 (0.4) 44 (5.67) 9. (20.50) 9.9 (2.8) (5.24) 05 (4.) 79 (7.05) 4. (.70) 50 (5.9) 200 (7.87) 270 (0.6) 44 (5.67) 0.2 (22.49) 0.8 (2.8) (5.24) 05 (4.) 79 (7.05) 42.5 (.67) 70 (6.69) 200 (7.87) 270 (0.6) 44 (5.67) 4.2 (.) 4.8 (2.6) 50 6 (5.24) 05 (4.) 79 (7.05) 54.5 (2.5) 65 (6.50) 200 (7.87) 275 (0.8) 44 (5.67) 2. (26.68) 2.7 (28.00) (5.24) 05 (4.) 79 (7.05) 54.5 (2.5) 65 (6.50) 200 (7.87) 275 (0.8) 44 (5.67) 2. (27.2) 2.9 (28.44) 50 6 (5.24) 05 (4.) 79 (7.05) 54.5 (2.5) 80 (7.09) 200 (7.87) 275 (0.8) 44 (5.67) 6. (5.94) 6.9 (7.26) (5.24) 05 (4.) 79 (7.05) 5.9 (2.2) 95 (7.68) 200 (7.87) 275 (0.8) 44 (5.67) 7.8 (9.24) 8.4 (40.57) 80 6 (5.24) 05 (4.) 79 (7.05) 82.5 (.25) 200 (7.87) 200 (7.87) 290 (.42) 54 (6.06) 6.8 (7.04) 7.4 (8.6) (5.24) 05 (4.) 79 (7.05) 82.5 (.25) 200 (7.87) 200 (7.87) 290 (.42) 54 (6.06) 8.8 (4.45) 9.4 (42.77) 80 6 (5.24) 05 (4.) 79 (7.05) 8.7 (.22) 25 (8.46) 200 (7.87) 290 (.42) 54 (6.06) 22.8 (50.27) 2.4 (5.59) (5.24) 05 (4.) 79 (7.05) 80.9 (.9) 20 (9.06) 200 (7.87) 290 (.42) 54 (6.06) 26.8 (59.08) 27.4 (60.4) 00 6 (5.24) 05 (4.) 79 (7.05) 07. (4.22) 220 (8.66) 250 (9.84) 0 (2.20) 64 (6.46) 2.4 (47.8) 22 (48.50) (5.24) 05 (4.) 79 (7.05) 07. (4.22) 25 (9.25) 250 (9.84) 0 (2.20) 64 (6.46) 24.4 (5.79) 25 (55.2) 00 6 (5.24) 05 (4.) 79 (7.05) 06. (4.9) 250 (9.84) 250 (9.84) 0 (2.20) 64 (6.46) 29.4 (64.82) 0 (66.4) (5.24) 05 (4.) 79 (7.05) 04. (4.) 265 (0.4) 250 (9.84) 0 (2.20) 64 (6.46) 5.4 (78.04) 6 (79.7) 50 6 (5.24) 05 (4.) 79 (7.05) 59. (6.27) 285 (.22) 00 (.8) 25 (2.80) 74 (6.85) 5.2 (77.60) 5.8 (78.9) (5.24) 05 (4.) 79 (7.05) 59. (6.27) 00 (.8) 00 (.8) 25 (2.80) 74 (6.85) 4.2 (90.8) 4.8 (92.5) 50 6 (5.24) 05 (4.) 79 (7.05) 57. (6.9) 45 (.58) 00 (.8) 25 (2.80) 74 (6.85) 59.2 (0.5) 59.8 (.84) (5.24) 05 (4.) 79 (7.05) 54. (6.07) 55 (.98) 00 (.8) 25 (2.80) 74 (6.85) 67.2 (48.5) 67.8 (49.47) (5.24) 05 (4.) 79 (7.05) (8.) 40 (.9) 00 (.8) 50 (.78) 94 (7.64) 7.8 (8.) 8.4 (84.66) (5.24) 05 (4.) 79 (7.05) (8.) 40 (.9) 00 (.8) 50 (.78) 94 (7.64) 7.8 (8.) 8.4 (84.66) (5.24) 05 (4.) 79 (7.05) (8.) 60 (4.7) 00 (.8) 50 (.78) 94 (7.64) 46.8 (0.8) 47.4 (04.50) (5.24) 05 (4.) 79 (7.05) (8.) 75 (4.76) 00 (.8) 50 (.78) 94 (7.64) 54.8 (20.8) 55.4 (22.4) (5.24) 05 (4.) 79 (7.05) (0.25) 95 (5.55) 80 (4.96) 70 (4.57) 224 (8.82) 57.4 (26.55) 58.0 (27.87) (5.24) 05 (4.) 79 (7.05) (0.25) 405 (5.94) 80 (4.96) 70 (4.57) 224 (8.82) 58.4 (28.75) 59.0 (0.07) (5.24) 05 (4.) 79 (7.05) (0.9) 425 (6.7) 80 (4.96) 70 (4.57) 224 (8.82) 74.4 (64.02) 75.0 (65.5) (5.24) 05 (4.) 79 (7.05) (0.9) 450 (7.72) 80 (4.96) 70 (4.57) 224 (8.82) 92.4 (20.7) 9.0 (205.0) 00 0 (5.24) 05 (4.) 79 (7.05) 09.7 (2.9) 445 (7.52) 450 (7.72) 95 (5.55) 244 (9.6) 75.7 (66.89) 76. (68.2) 00 6 (5.24) 05 (4.) 79 (7.05) 09.7 (2.9) 460 (8.) 450 (7.72) 95 (5.55) 244 (9.6) 82.2 (8.22) 82.8 (82.54) (5.24) 05 (4.) 79 (7.05) 07.9 (2.2) 485 (9.09) 450 (7.72) 95 (5.55) 244 (9.6) 98.7 (27.60) 99. (28.92) (5.24) 05 (4.) 79 (7.05) 07.9 (2.2) 55 (20.28) 450 (7.72) 95 (5.55) 244 (9.6) 27.5 (28.09) 28. (282.4) ) For dual converter: specified weight kg (6.7 lb). Siemens FI US Edition /65

12 Flow Measurement Siemens AG 204 SITRANS FX00 Flange version ASME B6.5 Size Pressure rating Dimensions [mm (inch)] Weight [kg (lb)] ) DN Class a b c d D L H l Flowmeter Flowmeter (without (with pressure pressure sensor) sensor) ½ 50 (5.24) 05 (4.) 79 (7.05) 5.8 (0.62) 90 (.54) 200 (7.87) 265 (0.4) 44 (5.67) 4.5 (9.92) 5. (.24) ½ 00 (5.24) 05 (4.) 79 (7.05) 5.8 (0.62) 95 (.74) 200 (7.87) 265 (0.4) 44 (5.67) 4.9 (0.80) 5.5 (2.) ½ 600 (5.24) 05 (4.) 79 (7.05).9 (0.55) 95 (.74) 200 (7.87) 265 (0.4) 44 (5.67) 5. (.24) 5.7 (2.57) 50 (5.24) 05 (4.) 79 (7.05) 26.6 (.05) 0 (4.) 200 (7.87) 265 (0.4) 44 (5.67) 6.2 (.67) 6.8 (4.99) 00 (5.24) 05 (4.) 79 (7.05) 26.6 (.05) 25 (4.92) 200 (7.87) 265 (0.4) 44 (5.67) 7.2 (5.87) 7.8 (7.20) 600 (5.24) 05 (4.) 79 (7.05) 24. (0.96) 25 (4.92) 200 (7.87) 265 (0.4) 44 (5.67) 7.5 (6.5) 8. (7.86) ½ 50 (5.24) 05 (4.) 79 (7.05) 40.9 (.6) 25 (4.92) 200 (7.87) 270 (0.6) 44 (5.67) 8. (8.0) 8.9 (9.62) ½ 00 (5.24) 05 (4.) 79 (7.05) 40.9 (.6) 55 (6.0) 200 (7.87) 270 (0.6) 44 (5.67) 0.4 (22.9) (24.25) ½ 600 (5.24) 05 (4.) 79 (7.05) 8. (.50) 55 (6.0) 200 (7.87) 270 (0.6) 44 (5.67).4 (25.) 2 (26.46) 2 50 (5.24) 05 (4.) 79 (7.05) 52.6 (2.07) 50 (5.9) 200 (7.87) 275 (0.8) 44 (5.67) (24.25).6 (25.57) 2 00 (5.24) 05 (4.) 79 (7.05) 52.6 (2.07) 65 (6.50) 200 (7.87) 275 (0.8) 44 (5.67) 2.4 (27.4) (28.66) (5.24) 05 (4.) 79 (7.05) 49. (.94) 65 (6.50) 200 (7.87) 275 (0.8) 44 (5.67).9 (0.64) 4.5 (.97) 50 (5.24) 05 (4.) 79 (7.05) 78 (.07) 90 (7.48) 200 (7.87) 290 (.42) 54 (6.06) 9.8 (4.65) 20.4 (44.97) 00 (5.24) 05 (4.) 79 (7.05) 78 (.07) 20 (8.27) 200 (7.87) 290 (.42) 54 (6.06) 22.8 (50.27) 2.4 (5.59) 600 (5.24) 05 (4.) 79 (7.05) 7.7 (2.90) 20 (8.27) 200 (7.87) 290 (.42) 54 (6.06) 2.8 (52.47) 24.4 (5.79) 4 50 (5.24) 05 (4.) 79 (7.05) 02.4 (4.0) 20 (9.06) 250 (9.84) 0 (2.20) 64 (6.46) 2.4 (5.59) 24 (52.9) 4 00 (5.24) 05 (4.) 79 (7.05) 02.4 (4.0) 255 (0.04) 250 (9.84) 0 (2.20) 64 (6.46).4 (69.2) 2 (70.55) (5.24) 05 (4.) 79 (7.05) 97.2 (.8) 275 (0.8) 250 (9.84) 0 (2.20) 64 (6.46) 40.4 (89.07) 4 (90.9) 6 50 (5.24) 05 (4.) 79 (7.05) 54.2 (6.07) 280 (.02) 00 (.8) 25 (2.80) 74 (6.85) 6.2 (79.8) 6.8 (8.) 6 00 (5.24) 05 (4.) 79 (7.05) 54.2 (6.07) 20 (2.60) 00 (.8) 25 (2.80) 74 (6.85) 5.2 (2.88) 5.8 (4.20) (5.24) 05 (4.) 79 (7.05) 46. (5.76) 55 (.98) 00 (.8) 25 (2.80) 74 (6.85) 46.2 (0.85) 76.8 (69.) 8 50 (5.24) 05 (4.) 79 (7.05) (7.98) 45 (.58) 00 (.8) 50 (.78) 94 (7.64) 50.0 (0.2) 50.6 (.55) 8 00 (5.24) 05 (4.) 79 (7.05) (7.98) 80 (4.96) 00 (.8) 50 (.78) 94 (7.64) 74.8 (64.9) 75.4 (66.2) 0 50 (5.24) 05 (4.) 79 (7.05) (0.02) 405 (5.94) 80 (4.96) 70 (4.57) 224 (8.82) 74.4 (64.02) 75.0 (65.5) 0 00 (5.24) 05 (4.) 79 (7.05) (0.02) 455 (7.9) 80 (4.96) 70 (4.57) 224 (8.82) 06.4 (24.57) 07.0 (25.89) 2 50 (5.24) 05 (4.) 79 (7.05) 04.8 (2.00) 485 (9.09) 450 (7.72) 95 (5.55) 244 (9.6) 06. (24.5) 06.9 (25.67) 2 00 (5.24) 05 (4.) 79 (7.05) 04.8 (2.00) 520 (20.47) 450 (7.72) 95 (5.55) 244 (9.6) 5. (.56) 5.9 (4.88) ) For dual converter: specified weight kg (6.7 lb). /66 Siemens FI US Edition

13 Siemens AG 204 Flow Measurement SITRANS FX00 a c b a c b H D D H l L d L d Sandwich version Sandwich version with pressure sensor Sandwich version EN Size Pressure Dimensions [mm (inch)] Weight [kg (lb)] rating DN PN a b c d D L H l Flowmeter Flowmeter (without (with pressure pressure sensor) sensor) (5.24) 05 (4.) 79 (7.05) 6 (0.6) 45 (.77) 65 (2.56) 265 (0.4) 44 (5.67).5 (7.72) 4. (9.04) (5.24) 05 (4.) 79 (7.05) 24 (0.94) 65 (2.56) 65 (2.56) 265 (0.4) 44 (5.67) 4. (9.48) 4.9 (0.80) (5.24) 05 (4.) 79 (7.05) 8 (.50) 82 (.2) 65 (2.56) 270 (0.6) 44 (5.67) 4.9 (0.80) 5.5 (2.) (5.24) 05 (4.) 79 (7.05) 50 (.97) 02 (4.02) 65 (2.56) 275 (0.8) 44 (5.67) 6 (.2) 6.6 (4.55) (5.24) 05 (4.) 79 (7.05) 74 (2.9) 5 (5.) 65 (2.56) 290 (.42) 55 (6.0) 8.2 (8.08) 8.8 (9.40) (5.24) 05 (4.) 79 (7.05) 97 (.82) 58 (6.22) 65 (2.56) 0 (2.20) 64 (6.46) 9.5 (20.94) 0. (22.27) Sandwich version ASME Size Pressure rating Dimensions [inch] Weight [lb] DN Class a b c d D L H l Flowmeter Flowmeter (without (with pressure pressure sensor) sensor) ½" 50, 00, " 50, 00, ½" 50, 00, " 50, 00, " 50, 00, " 50, 00, Siemens FI US Edition /67

14 Flow Measurement Siemens AG 204 SITRANS FX00 Remote version Flanged version DN ½" " ½" 2" " 4 " 6" 8" 0" 2" a [mm] [inch] b c d e f g h j k l m n p [mm] 40 Ø Ø5 Ø9 (4x) [inch] 5.52 Ø Ø4.5 Ø0.6 (4x) Sandwich version DN ½" " ½" 2" " 4 " a [mm] [inch] b c d e f g h j k l m n p [mm] 40 Ø Ø5 Ø9 (4x) [inch] 5.52 Ø Ø4.5 Ø0.6 (4x) /68 Siemens FI US Edition

15 Siemens AG 204 Flow Measurement SITRANS FX00 Flow tables Measuring Range Limits Water Size Q min Q max Q min Q max DN to EN 092- DN to ASME B6.5 EN 092- [m /h] EN 092- [m /h] ASME B6.5 [m /h] ASME B6.5 [m /h] 5 ½" " ½" " " " " " " " Values based on water at 20 C (68 F) Air Size Q min Q max Q min Q max DN to EN 092- DN to ASME B6.5 EN 092- [m /h] EN 092- [m /h] ASME B6.5 [m /h] ASME B6.5 [m /h] 5 ½" " ½" " " " " " " " Values based on air at 20 C (68 F) and.0 bar abs (4.7 psi abs ) Flow rate limits Product Nominal diameters Minimum flow rates Maximum flow rates to EN to ASME [m/s] [m/s] Liquids DN 5 DN 00 DN ½" DN 2" 0.5 x (998/) 0.5 ) 7 x (998/) 0.47 ) Gas, steam/vapor DN 5 DN 00 DN ½" DN 2" 6 x (.29/) 0.5 2) 7 x (998/) 0.47 ) = operating density [kg/m ] ) Minimum flow rate 0. m/s (0.984 ft/s), maximum flow rate 7 m/s (2 ft/s) 2) Minimum flow rate 2 m/s (6.6 ft/s) ) Maximum flow rate 80 m/s (262 ft/s); DN 5: 45 m/s (48 ft/s) and DN 25: 70 m/s (20 ft/s) Siemens FI US Edition /69

16 Flow Measurement Siemens AG 204 SITRANS FX00 Measuring range saturated steam: to 7 bar Overpressure [bar] Density [kg/m³] Temperature [ C] Flow [kg/h] min. max. min. max. min. max. min. max. DN to EN 092- DN to ASME B6.5 5 ½" " ½" " " " " " " " Measuring range saturated steam: 0.5 to 20 bar Overpressure [bar] Density [kg/m³] Temperature [ C] Flow [kg/h] min. max. min. max. min. max. min. max. DN to EN 092- DN to ASME B6.5 5 ½" " ½" " " " " " " " /70 Siemens FI US Edition

17 Siemens AG 204 Flow Measurement SITRANS FX00 Measuring range saturated steam: 5 to 00 psig Overpressure [psig] Density [lb/ft³] Temperature [ F] Flow [lb/h] min. max. min. max. min. max. min. max. DN to EN 092- DN to ASME B6.5 5 ½" " ½" " " " " " " " Measuring range saturated steam: 50 to 00 psig Overpressure [psig] Density [lb/ft³] Temperature [ F] Flow [lb/h] min. max. min. max. min. max. min. max. DN to EN 092- DN to ASME B6.5 5 ½" " ½" " " " " " " " Siemens FI US Edition /7

18 Flow Measurement Siemens AG 204 Notes /72 Siemens FI US Edition

Flow Measurement SITRANS F X SITRANS FX300 4/365

Flow Measurement SITRANS F X SITRANS FX300 4/365 Siemens AG 200 Overview vortex flowmeters provide accurate volumetric and mass flow measurement of steam, gases and liquids as an all-in-one solution with integrated temperature and pressure compensation.

More information

SITRANS FX300 4/289. System Overview. Overview

SITRANS FX300 4/289. System Overview. Overview Siemens G 2008 SITRNS F flowmeters Overview System Overview Version Single transmitter Dual transmitter Options Standard Pressure sensor Flange Pressure sensor and isola- Standard tion valve Sandwich vortex

More information

VersaFlow Vortex 100 Vortex Flow Meter Specifications

VersaFlow Vortex 100 Vortex Flow Meter Specifications VersaFlow Vortex 100 Vortex Flow Meter Specifications 34-VF-03-05 May 2011 The All-In-One Solution The VERSAFLOW is the only vortex flowmeter with integrated and temperature compensation in 2- wire technology.

More information

VersaFlow Vortex 100 Vortex Flow Meter Specifications

VersaFlow Vortex 100 Vortex Flow Meter Specifications VersaFlow Vortex 100 Vortex Flow Meter Specifications 34-VF-03-05 May 2011 The All-In-One Solution The VERSAFLOW is the only vortex flowmeter with integrated pressure and temperature compensation in 2-

More information

OPTISWIRL 4070 Technical Datasheet

OPTISWIRL 4070 Technical Datasheet OPTISWIRL 4070 Technical Datasheet Vortex flowmeter Integrated pressure and temperature compensation Temperature compensation for saturated steam included as standard All OPTISWIRL versions in 2-wire technology

More information

OPTISWIRL 4070 Technical Datasheet

OPTISWIRL 4070 Technical Datasheet OPTISWIRL 4070 Technical Datasheet Vortex flowmeter Integrated pressure and temperature compensation Temperature compensation for saturated steam included as standard All OPTISWIRL versions in 2-wire technology

More information

VersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet. Specification. The all-in-one solution. Highlights. Industries.

VersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet. Specification. The all-in-one solution. Highlights. Industries. VersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet 34-VF-03-05 September 3rd, 2008 Specification The all-in-one solution The VERSAFLOW is the only vortex flowmeter with integrated pressure and

More information

Vortex Flowmeters VFM 3100 F-T VFM 3100 W-T

Vortex Flowmeters VFM 3100 F-T VFM 3100 W-T KROHNE 10/2001 7.02313.23.00 GR/OP Vortex Flowmeters F-T W-T Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters Level measuring

More information

OPTISWIRL 4200 Technical Datasheet

OPTISWIRL 4200 Technical Datasheet OPTISWIRL 4200 Technical Datasheet Vortex flowmeter Integrated pressure and temperature compensation Gross and net heat measurement for hot water and steam Stable measurements even under demanding process

More information

OPTISWIRL 4200 Technical Datasheet

OPTISWIRL 4200 Technical Datasheet OPTISWIRL 4200 Technical Datasheet Vortex flowmeter Integrated pressure and temperature compensation Development acc. to IEC 61508 edition 2, for SIL2 Gross and net heat measurement for hot water and steam

More information

Flow Measurement SITRANS F C. Flow sensor MASS 2100 DI 3 to DI 40. 4/180 Siemens FI

Flow Measurement SITRANS F C. Flow sensor MASS 2100 DI 3 to DI 40. 4/180 Siemens FI Siemens AG Flow sensor MASS DI 3 to DI 0 Overview MASS DI 3 to DI 0 is suitable for accurate mass flow measurement of a variety of liquids and gases. The sensor offers superior performance in terms of

More information

Flow Measurement SITRANS F C

Flow Measurement SITRANS F C Overview Benefits It is compact and light, fitting neatly into dense piping arrangements Effective separation of measurement from plant vibration Reliable measurements due to high signal to noise ratio

More information

Level instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview.

Level instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview. Overview Configuration is an inverse frequency shift capacitance continuous It is ideal for standard industrial applications in chemical, hydrocarbon processing, food and beverage and mining, aggregate

More information

SITRANS F flowmeters SITRANS F US. SITRANS FUT1010 Ultrasonic flowmeter. Overview. Application

SITRANS F flowmeters SITRANS F US. SITRANS FUT1010 Ultrasonic flowmeter. Overview. Application Overview SITRANS F flowmeters Application Liquid applications Gas applications Pipelines Custody transfer, allocation, Upstream Production wells, line balance, gathering, separation interface/densitometer

More information

Multivariable Vortex Flow Meter

Multivariable Vortex Flow Meter Multivariable Vortex Flow Meter DVH Sensor Design w/o sealing Fully welded sensor Integrated temperature and pressure measurement (optional) Calculation of mass and density possible High temperature version

More information

SITRANS F C. Flow sensor MC2 4/193. Overview

SITRANS F C. Flow sensor MC2 4/193. Overview Siemens G 2011 low Measurement SITNS C Overview The main applications of the Coriolis flowmeter can be found in all industries, such as: Chemical and pharma Detergents, bulk chemicals, pharmaceuticals,

More information

Multivariable Vortex Flow Meter

Multivariable Vortex Flow Meter Multivariable Vortex Flow Meter DVH Sensor Design w/o sealing Fully welded sensor Integrated temperature and pressure measurement (optional) Calculation of mass and density possible High temperature version

More information

F-2600 SERIES INLINE VORTEX FLOW METER

F-2600 SERIES INLINE VORTEX FLOW METER F-2600 SERIES INLINE VORTEX FLOW METER APPLICATIONS Saturated steam Hot water to 500 F (260 C) standard 750 F (400 C) optional Applications with optional pressure sensor Superheated steam to 500 F (260

More information

Armstrong In-Line and Insertion Vortex Flow Meters

Armstrong In-Line and Insertion Vortex Flow Meters Armstrong In-Line and Insertion Vortex Flow Meters Designs, materials, weights and performance ratings are approximate and subject to change without notice. Visit for up-to-date information. 1 In-Line

More information

Satellite photo of cloud vortices caused by a mountain (Courtesy of our friends at NASA) tekvorx Operation Showing Simplified Construction

Satellite photo of cloud vortices caused by a mountain (Courtesy of our friends at NASA) tekvorx Operation Showing Simplified Construction Sensing the pulse of industry tekvorx TV01 Multivariable Vortex flow Sensors Vortex flow sensors derive their name from a natural phenomenon of fluid dynamics. When a gas or relatively low viscosity liquid

More information

SITRANS F flowmeters SITRANS F C

SITRANS F flowmeters SITRANS F C SITRNS F flowmeters Siemens G 2008 Overview is available as a standard version (DN 50 to DN 150 (2 to 6 )) and a hygienic, EHEDG certified version (DN 20 to DN 80 (¾ to 3 )). MC2 and MC2 hygienic are suitable

More information

VORTEX FLOW METTER DVH. Despriction. Advantages of the DVH Vortex Flow Meter

VORTEX FLOW METTER DVH. Despriction. Advantages of the DVH Vortex Flow Meter R VORTEX FLOW METTER DVH Measuring range: 3-8... 3 057-280 187 m3n/h Accuray: ± 0,7 % of reading (liquids) ± 1 % of reading (gases and steam) P m a x : 100 bar abs; tm ax : 400 C Connection: ANSI ½ up

More information

Vortex Flow Meter Model DVH

Vortex Flow Meter Model DVH Vortex Flow Meter measuring monitoring analysing DVH Measuring range: 3-8... 3057-280187 Nm³/h Accuracy: ± 0,7 % of reading (liquids) ± 1 % of reading (gases and steam) p max : 100 bar abs; t max : 400

More information

SITRANS F flowmeters SITRANS F C SITRANS F C MC2 4/169. Overview

SITRANS F flowmeters SITRANS F C SITRANS F C MC2 4/169. Overview Siemens G 2009 SITRNS flowmeters SITRNS C SITRNS C MC2 Overview SITRNS C MC2 is available as a standard version (DN 50 to DN 150 (2 to 6 )) and a hygienic, EHEDG-certified version (DN 20 to DN (¾ to 3

More information

Flow Measurement SITRANS F C

Flow Measurement SITRANS F C Overview The complete flowmeter system SITRANS FC40 can be ordered for standard, hygienic or NAMUR service. All versions can be ordered for CT service, according to OIML R 117 (Liquids other than water)

More information

Vortex Flowmeter Model DVE

Vortex Flowmeter Model DVE Vortex Flowmeter Multi-Parameter measuring monitoring analysing DVE Measuring range Liquids: 5.2-157... 284-85371 m³/h Air: 89-1463... 26915-2467081 Nm 3 /h (20 C, 0 bar rel) Saturated steam: 81-938...

More information

SITRANS FC. Flowmeter SITRANS FC410

SITRANS FC. Flowmeter SITRANS FC410 Siemens AG 2013 Flow Measurement Overview The Coriolis flowmeter 410 consists of a SITRANS FCS400 sensor and a T010 transmitter, always compact mounted. It is based on the latest developments within digital

More information

F-2700 SERIES INSERTION VORTEX FLOW METER

F-2700 SERIES INSERTION VORTEX FLOW METER F-2700 SERIES INSERTION VORTEX FLOW METER APPLICATIONS Saturated steam Hot water to 500 F (260 C) standard 750 F (400 C) optional Applications with optional pressure sensor Superheated steam to 500 F (260

More information

F-2700 SERIES INSERTION VORTEX FLOW METER

F-2700 SERIES INSERTION VORTEX FLOW METER F-2700 SERIES INSERTION VORTEX FLOW METER CALIBRATION Every ONICON flow meter is wet calibrated in a flow laboratory against standards that are directly traceable to N.I.S.T. A certificate of calibration

More information

F-2500 SERIES VORTEX METER

F-2500 SERIES VORTEX METER F-500 SERIES VORTEX METER APPLICATIONS Saturated steam Hot water to F (0 C) Applications with optional pressure sensor Superheated steam to F (0 C) Compressed air Industrial gases CALIBRATION Each meter

More information

SITRANS F M flow sensors 711/A and 711/911E

SITRANS F M flow sensors 711/A and 711/911E s flow sensors 711/A and 711/911E flow sensors 711/A and 711/911E Introduction Application Mode of operation, operation Mode of operation All electromagnetic flow measurements are based on Faraday s Law

More information

DVH. Vortex Flowmeter. Measuring range: Nm³/h. Accuracy: ± 0,7% of reading (liquids) ± 1% of reading (gases and steam) p max

DVH. Vortex Flowmeter. Measuring range: Nm³/h. Accuracy: ± 0,7% of reading (liquids) ± 1% of reading (gases and steam) p max Vortex Flowmeter measuring monitoring analysing DVH Measuring range: 3-8... 3057-280187 Nm³/h Accuracy: ± 0,7% of reading (liquids) ± 1% of reading (gases and steam) p max : 100 bar abs; t max : 400 C

More information

Level Measurement. Continuous level measurement - Capacitance transmitters SITRANS LC500. 5/282 Siemens FI Overview.

Level Measurement. Continuous level measurement - Capacitance transmitters SITRANS LC500. 5/282 Siemens FI Overview. SITRANS LC00 Overview Configuration Installation Build up of material or condensation in active shield area does not affect switch operation. SITRANS LC00 is an inverse frequency shift capacitance level

More information

Flow Measurement SITRANS F C

Flow Measurement SITRANS F C Siemens G 2014 SITRNS C Overview The main applications of the Coriolis flowmeter can be found in all industries, such as: Chemical and pharma Detergents, bulk chemicals, pharmaceuticals, acids, alkalis

More information

F-2600 SERIES INLINE VORTEX FLOW METER

F-2600 SERIES INLINE VORTEX FLOW METER F-2600 SERIES ININE VORTEX FOW METER APPICATIONS Saturated steam Hot water to 500 F (260 C) standard 750 F (400 C) optional Applications with optional pressure sensor Superheated steam to 500 F (260 C)

More information

OPTIMASS 2000 Technical Datasheet

OPTIMASS 2000 Technical Datasheet OPTIMASS 2000 Technical Datasheet Sensor for bulk mass flow Large diameter for bulk measurement and custody transfer of liquids and gases Stainless Steel measuring tubes (NACE Compliant) Modular electronics

More information

Pro-V Multivariable Flowmeter Model M24 In-line Vortex

Pro-V Multivariable Flowmeter Model M24 In-line Vortex Pro-V Multivariable Flowmeter Model M24 In-line Vortex Pro-V TM Advantage: VorTek Instruments Pro-V multivariable flowmeters utilize three primary sensing elements a vortex shedding velocity sensor, an

More information

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M Overview The electromagnetic sensor MAG 1100 F is designed to meet applications in the food and beverage industry. Benefits sizes: 10 to 100 (/8 to 4 ) AISI 16 stainless steel enclosure : Hygienic connection,

More information

SITRANS F flowmeters SITRANS F C MASSFLO MASS MC1. 4/146 Siemens FI Overview

SITRANS F flowmeters SITRANS F C MASSFLO MASS MC1. 4/146 Siemens FI Overview Overview MSS 2100 MC1 DN 50 to DN 150 (2 to 6 ) is suitable for accurate mass flow measurement for all kind of liquids and gases. The sensor offers superior performance in terms of flow accuracy, turn-down

More information

OPTIMASS 3000 Technical Datasheet

OPTIMASS 3000 Technical Datasheet OPTIMASS 3000 Technical Datasheet Sensor for mass flow First choice for low flow applications Certified secondary pressure containment A common footprint for all three sizes, in Hastelloy or Stainless

More information

The EPSILON is based on the principle of measuring velocity in the pipe line, therefore the flow measurement is volumetric.

The EPSILON is based on the principle of measuring velocity in the pipe line, therefore the flow measurement is volumetric. Typical Applications EPSILON Flowmeter The EPSILON flow meters measure the flow of most liquids and gases within the process industries, including chemical, petro-chemical, pharmaceutical and the power

More information

VFM4070C SWIRLMAX. Vortex Flowmeter OUTLINE FEATURES OPERATING PRINCIPLE STANDARED SPECIFICATION. General Specification. Sensor Specification

VFM4070C SWIRLMAX. Vortex Flowmeter OUTLINE FEATURES OPERATING PRINCIPLE STANDARED SPECIFICATION. General Specification. Sensor Specification SWIRMAX VFM4070C Vortex Flowmeter OUTINE SWIRMAX is 2-wire, all-in-one type vortex flowmeter with both temperature and pressure sensors integrally mounted into the housing. It allows temperature and pressure

More information

VIM20 Vortex Insertion Flowmeter

VIM20 Vortex Insertion Flowmeter VIM20 Principle of Operation Vortex flowmeters measure flows of liquid, gas and steam by detecting the frequency at which vortices are alternately shed from a bluff body. According to proven laws of physics,

More information

Continuous level measurement Capacitance transmitters

Continuous level measurement Capacitance transmitters Siemens AG 2011 Level Measurement SITRANS LC00 Overview Configuration Installation Build up of material or condensation in active shield area does not affect switch operation. SITRANS LC00 is an inverse

More information

Magnetic-inductive flow meter for hazardous areas

Magnetic-inductive flow meter for hazardous areas Magnetic-inductive flow meter for hazardous areas Technical Datasheet EPX / UMF3 high accuracy: 0.3 % of actual maintenance-free no pressure drop numerous lining materials numerous electrode materials

More information

SITRANS F M. Flow sensor MAG 1100 F 3/59

SITRANS F M. Flow sensor MAG 1100 F 3/59 Overview Integration The complete flowmeter consists of a sensor and an associated transmitter MAG 5000, 6000 and 6000 I. The flexible communication concept USM II simplifies integration and update to

More information

SITRANS P measuring instruments for pressure

SITRANS P measuring instruments for pressure Overview Application The pressure transmitter is designed for the special requirements of the food, pharmaceutical and biotechnology industries. The use of high-grade materials guarantees compliance with

More information

SITRANS P measuring instruments for pressure

SITRANS P measuring instruments for pressure Overview Siemens AG 009 Supplementary electronics for 4-wire connection Design Dimensions (W x H x D) in mm (inch) Electrical connection 80 x 10 x 60 (3.15 x 4.7 x.36) Screw terminals (Pg 13.5 cable inlet)

More information

Level Measurement Point level measurement - RF Capacitance switches

Level Measurement Point level measurement - RF Capacitance switches Overview Configuration Installation is an inverse frequency shift capacitance level and material detection switch ideal for detecting interfaces, solids, liquids, toxic, and aggressive chemicals in critical

More information

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727) F-1500 SERIES INSERTION TURBINE FLOW METER Insertion turbine flow meters are ideal for use in larger steam lines where downsizing the line size to improve flow measurement is not desirable. In these applications,

More information

STEEMCO Flowmeter for Steam

STEEMCO Flowmeter for Steam STEEMCO Flowmeter for Steam Typical Applications The STEEMCO flow meters measure the flow of saturated and superheated steam within the process industries, including chemical, petro-chemical, pharmaceutical

More information

Magnetic-inductive flow meter EPS / UMF2. Technical data sheet

Magnetic-inductive flow meter EPS / UMF2. Technical data sheet Magnetic-inductive flow meter EPS / UMF2 Technical data sheet high accuracy: 0.3 % of actual maintenance-free no pressure drop numerous lining materials numerous electrode materials low-cost grounding

More information

LCMass Series Mass Flow Sensor

LCMass Series Mass Flow Sensor LCMass 100-140 Series Mass Flow Sensor Technical Data Sheet HIGH ACCURACY The LCMass 100 achieves a ±0.15% accuracy on liquids. COMPACT ECONOMIC DESIGN Straight twin-tube design allows for an overall smaller

More information

Level Measurement Point level measurement - RF Capacitance switches

Level Measurement Point level measurement - RF Capacitance switches Pointek CLS200 - Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level and material detection switch with optional rod/cable

More information

Vortex Eggs Delta Flowmeter

Vortex Eggs Delta Flowmeter Product Data Sheet PDS-FLM Vortex Eggs Delta Flowmeter Technical Specifications (Liquid, Gas & Air) Easy to read Free positioning EEPROM DESCRIPTION The unique sensor body and transmitter design makes

More information

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview. Pointek CLS200 Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level switch with optional rod/cable choices liquids, solids,

More information

Food & beverage. Oil & gas. Water & waste water

Food & beverage. Oil & gas. Water & waste water Overview MSS 2100 MC1 DN 50 to DN 150 (2 to 6 ) are suitable for accurate mass flow measurement for all kind of liquids and gases. The sensor offers superior performance in terms of flow accuracy, turn-down

More information

Level Measurement Continuous level measurement Ultrasonic transmitters

Level Measurement Continuous level measurement Ultrasonic transmitters Siemens AG 2018 Overview Configuration ultrasonic level transmitter, ideal for level, volume, and volume flow measurements. It works with liquids, slurries, and bulk materials up to 12 m (0 ft). Benefits

More information

ORIMAS Mass Flowmeter

ORIMAS Mass Flowmeter Typical Applications ORIMAS Mass Flowmeter The ORIMAS mass flow meters measure the mass flow of most liquids and gases within the process industries, including chemical, petro-chemical, pharmaceutical

More information

Pressure transducer DMU 01K Compact version

Pressure transducer DMU 01K Compact version Pressure transducer DMU 01K Compact version Dimensions (in mm) Wiring diagram 8 Application Special OEM unit. For electronic pressure measurement in industrial or HVAC applications (such as hydraulic,

More information

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd Pointek CLS200 Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level switch with optional rod/cable choices liquids, solids,

More information

Flow Measurement SITRANS F M. Flow sensor MAG 1100 F 4/57

Flow Measurement SITRANS F M. Flow sensor MAG 1100 F 4/57 Overview Integration The complete flowmeter consists of a sensor and an associated transmitter MAG 5000, 6000 and 6000 I. The flexible communication concept USM II simplifies integration and update to

More information

BGN. All Metal Variable Area Flow Meter. Technical Data Sheet

BGN. All Metal Variable Area Flow Meter. Technical Data Sheet All Metal Variable Area Flow Meter BGN Technical Data Sheet Extremely robust through star guiding system instead of guiding rod Flow metering of liquids, gases and steam Available up to nominal size of

More information

STEEMCO-MAS Flowmeter for Steam

STEEMCO-MAS Flowmeter for Steam STEEMCO-MAS Flowmeter for Steam Typical Applications The STEEMCO-MAS flow meters measure the mass flow of superheated steam within the process industries, including chemical, petro-chemical, pharmaceutical

More information

UFM 800 W, C and UFM 800 W Hot Tapping. Ultrasonic flowmeters. for water and wastewater

UFM 800 W, C and UFM 800 W Hot Tapping. Ultrasonic flowmeters. for water and wastewater KROHNE 12/2006 7.02343.22.00 MAR UFM 800 W, C and UFM 800 W Hot Tapping Ultrasonic flowmeter for water and wastewater...with weld-in sensors for metal pipelines...with built-on or built-in sensors for

More information

F-1500 SERIES INSERTION TURBINE FLOW METER

F-1500 SERIES INSERTION TURBINE FLOW METER F-1500 SERIES INSERTION TURBINE FLOW METER APPLICATIONS Saturated steam Hot water to 450 F (232 C) standard 850 F (454 C) optional Applications with optional pressure sensor Superheated steam to 450 F

More information

OPTIFLUX 6000 Technical Datasheet

OPTIFLUX 6000 Technical Datasheet OPTIFLUX 6000 Technical Datasheet Electromagnetic flow sensor for hygienic and sanitary applications Robust stainless steel housing for hygienic and aseptic operation Fully suitable for CIP and SIP Typical

More information

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M Overview The electromagnetic sensor MAG 1100 F is designed to meet applications in the food and beverage industry. Benefits sizes: 10 to 100 (/8 to 4 ) AISI 16 stainless steel enclosure : Hygienic connection,

More information

Level Measurement Continuous level measurement - Capacitance transmitters

Level Measurement Continuous level measurement - Capacitance transmitters Overview Probe Applications Rod version Rod version with stilling well Cable version PFA coated cable version Extended cable with rod version Conductive liquids, slurries or solids Conductive liquids or

More information

Point level measurement Capacitance switches

Point level measurement Capacitance switches Pointek CLS300 Standard Overview Configuration Installation Pointek CLS300 (standard version) is an inverse frequency shift capacitance level switch with optional rod/cable choices and configurable output.

More information

VORTEX IN-LINE FLOW METERS

VORTEX IN-LINE FLOW METERS VORTEX IN-LINE FLOW METERS Principles of Operation Vortices are created when a fluid passes around a bluff body as shown below. Vortices are alternately shed on each side of the body, degrees out of phase

More information

Transmitting Transducer. Gas/Air Velocity Range:

Transmitting Transducer. Gas/Air Velocity Range: RNG Series Insertion-Style Gas Flow Meter The RNG Series meter is an insertion-style vortex shedding flow meter designed to offer high accuracy measurements over an extremely large flow range. The meters

More information

Vortex In Line Flow Meter

Vortex In Line Flow Meter Principles of Operation Vortices are created when a fluid passes around a bluff body as shown below. Vortices are alternately shed on each side of the body, 0 degrees out of phase to each other, resulting

More information

The readings you need, right where you need them. AX Series Vortex Meters

The readings you need, right where you need them. AX Series Vortex Meters The readings you need, right where you need them. AX Series Vortex Meters Multivariable function from a single meter Vortex multivariable meters from Azbil North America employ three sensing elements in

More information

Accurate measurement of compressed air consumption and detection of leaks. Measuring the individual consumption per customer / cost centre

Accurate measurement of compressed air consumption and detection of leaks. Measuring the individual consumption per customer / cost centre Inline Flowmeter for compressed air and gases DN15 - DN50 / 16 bar The flow meter of the series, based on the measurement principle of thermal mass flow, is ideally suited for the measurement of flow of

More information

Pressure Measurement

Pressure Measurement Siemens AG 202 /2 Product overview Transmitters for basic requirements /5 SITRANS P200 for gauge and absolute pressure / SITRANS P20 for gauge pressure /6 SITRANS P220 for gauge pressure /22 SITRANS P250

More information

VLM20 In-line Vortex Flowmeter

VLM20 In-line Vortex Flowmeter ocal regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

VIM20 Vortex Insertion Flowmeter

VIM20 Vortex Insertion Flowmeter Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

Flow Measurement SITRANS F C

Flow Measurement SITRANS F C verview The flow measuring principle is based on the Coriolis Effect. The FCS400 sensor s measuring tubes are energized by an electromechanical driver circuit which oscillates them at their resonance frequency.

More information

Inline Flow meter for compressed air and gases DN15 (1/2 ) - DN80 (3 )

Inline Flow meter for compressed air and gases DN15 (1/2 ) - DN80 (3 ) EE771/EE772 Inline Flow meter for compressed air and gases DN15 (1/2 ) - DN80 (3 ) The inline flow meter EE771/EE772, based on the measurement principle of thermal mass flow, is ideally suited for the

More information

SITRANS T measuring instruments for temperature

SITRANS T measuring instruments for temperature for installation in pipelines and tanks Overview The resistance thermometer is designed for installation in tanks and pipelines as well as for the measurement of temperature with hygiene requirements.

More information

VIM20 Vortex Insertion Flowmeter

VIM20 Vortex Insertion Flowmeter Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

Vortex Flow Sensors VA Di also suitable for applications in condensation and particle laden gases. Drawing 1

Vortex Flow Sensors VA Di also suitable for applications in condensation and particle laden gases. Drawing 1 Vortex Flow Sensors VA Di Vortex Flow Sensors VA Di also suitable for applications in condensation and particle laden gases Drawing 1 Measurable variable actual flow rate standard velocity standard flow

More information

PanaFlow MV80. In-line Multivariable Flowmeter for Mass, Temperature, and Pressure. GE Sensing. Applications. Key Benefits

PanaFlow MV80. In-line Multivariable Flowmeter for Mass, Temperature, and Pressure. GE Sensing. Applications. Key Benefits Key Benefits Multivariable vortex flowmeter for measuring volumetric flow, temperature, pressure, density, and mass flow using a single meter Measures most gases, liquids and steam without the need to

More information

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam Metal tube flowmeters Variable area flowmeter for liquids, gases and steam Metallic or plastic tube with a robust construction Indication by means of magnetic coupling Scales calibrated in l/h, m 3 /h,

More information

Vortex In Line Flow Meter

Vortex In Line Flow Meter Vortex In Line Flow Meter Principles of Operation Vortices are created when a fluid passes around a bluff body as shown below. Vortices are alternately shed on each side of the body, 0 degrees out of phase

More information

SATRON VT Pressure Transmitter

SATRON VT Pressure Transmitter SATRON VT pressure transmitter belongs to the series V-transmitters. SATRON VT is used for 0-1.4 kpa...0-100 MPa ranges. It is a 2-wire transmitter with HART standard communication. In pressure measuring

More information

Metal tube flowmeters Series M21 Variable area flowmeter for low flows of liquids, gases and steam

Metal tube flowmeters Series M21 Variable area flowmeter for low flows of liquids, gases and steam Metal tube flowmeters Series M21 Variable area flowmeter for low flows of liquids, gases and steam Metallic tube with a robust construction Indication by means of magnetic coupling Scales calibrated in

More information

BATCHFLUX 5500 C Technical Datasheet

BATCHFLUX 5500 C Technical Datasheet BATCHFLUX 5500 C Technical Datasheet Electromagnetic flowmeter for volumetric filling machines High-stability zirconium oxide measuring tube Extreme long-term stability Most compact and lightweight design

More information

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids For use in large diameter pipes as an economical solution for flow measurement Flow rate measurement

More information

The readings you need, right where you need them. AX Series Vortex Meters

The readings you need, right where you need them. AX Series Vortex Meters The readings you need, right where you need them. AX Series Vortex Meters Multivariable function from a single meter Principles of Operation Vortex multivariable meters from Azbil North America employ

More information

Vortex Flowmeter FV4000 (TRIO-WIRL V) Swirl Flowmeter FS4000 (TRIO-WIRL S) For flow rate and volume measurement of liquids, gases and steam

Vortex Flowmeter FV4000 (TRIO-WIRL V) Swirl Flowmeter FS4000 (TRIO-WIRL S) For flow rate and volume measurement of liquids, gases and steam Vortex Flowmeter FV4000 (TRIO-WIRL V) Swirl Flowmeter FS4000 (TRIO-WIRL S) For flow rate and volume measurement of liquids, gases and steam Cost savings due to high accuracy Low investment cost through

More information

Digital Vortex Flowmeter. digitalyewflo. Digital Vortex Flowmeter. Series

Digital Vortex Flowmeter. digitalyewflo. Digital Vortex Flowmeter. Series Digital Vortex meter digitalyewflo Digital Vortex meter Series Unrivaled Performance, Functionality and Ease of Use Series Standard Type / Multi-variable Type High Temperature / Cryogenic Type Reduced

More information

Flow Measurement SITRANS F M. Flow sensor MAG /85. Overview

Flow Measurement SITRANS F M. Flow sensor MAG /85. Overview Siemens AG 2010 low Measurement Overview Design Compact or remote mounting possible Easy plug & play field changeability of transmitter Ex ATEX and M/CSA versions High temperature sensor for applications

More information

SITRANS F flowmeters. SITRANS F O delta p - Primary differential pressure devices Metering pipe with orifice plate and annular chambers 4/369

SITRANS F flowmeters. SITRANS F O delta p - Primary differential pressure devices Metering pipe with orifice plate and annular chambers 4/369 and annular chambers Application Suitable for non-corrosive and corrosive gases, vapors and liquids; permissible operating temperature -10 to +00 C. Design Orifice plate with annular chambers consisting

More information

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram Data Sheet 403025 Page 1/10 JUMO dtrans p20 Process pressure transmitter Brief description The JUMO dtrans p20 pressure transmitter with HART interface combines maximum precision with easy operation. It

More information

KDM ARMORED FLOW METER & SWITCH

KDM ARMORED FLOW METER & SWITCH KDM ARMORED FLOW METER & SWITCH Flow Pressure Level Temperature measurement monitoring control S2 Short Installation Length SS, PTFE or Hastelloy Wetted Parts Analog Output Available 110 F to + 390 F Temperature

More information

Micro Motion F-Series Coriolis Flow and Density Meters

Micro Motion F-Series Coriolis Flow and Density Meters Product Data Sheet PS-00603, Rev. F December 2007 Micro Motion F-Series Coriolis Flow and Density Meters Micro Motion F-Series Coriolis meters offer highly accurate mass flow, volume flow, and density

More information

Metal tube variable area flowmeter for gases, liquids and steam

Metal tube variable area flowmeter for gases, liquids and steam Metal tube variable area flowmeter for gases, liquids and steam Metallic or plastic tube with a robust construction Indication by means of magnetic coupling Scales calibrated in l/h, m 3 /h, kg/h, t/h,

More information

Low Profile Insertion Vortex

Low Profile Insertion Vortex Low Profile Insertion Vortex Product Features The same insertion meter can measure Steam, Gases or Liquids. Standardize on an insertion bar that can measure line sizes 2 24 Heavy Duty & Maintenance Free

More information