PROPOSAL. DATE DESCRIPTION PAGE 12/2/2013 Prairie Data/Elec. additions

Size: px
Start display at page:

Download "PROPOSAL. DATE DESCRIPTION PAGE 12/2/2013 Prairie Data/Elec. additions"

Transcription

1

2 PR# 248 2/2/203 Prairie Data/Elec. additions The power additions are for the Grandstand location and the High School location in the back of the Auditorium and include all material and laabor required to complete the circiut extensions to the new panels for Johnson Controls and the metering. The data additions are for all CAT5 cable, ends, piping,attachments and labor reqiured in all locations with Johnson Controls panles needing to be tied into the network. All sited were reviewed to determine the nearest locations for tie in. Per revised locations from district IT. This quote excludes work required for Priarie Crest Elementary. All data additions required for operational integration with , Johnson Controls to the New metering system - LS All power additions required to extend cicuits to the , Johnson Controls panels and Metering panels in locations where power is not available within the gear room - LS Deduct for PME-2 basement , TAL AMOUNT 5,32.00 Please fax signed acceptance to (39)

3 PR# 297 Craig Barnum (39) /4/203 Power Wiring Modifications Cost is for cooridination of shutdowns and rewiring of MDP's at Prairie Ridge, Prairie Creek and the HS MDP near the auditorium. An average of 8 hours per incident is expected for these tasks to be completed safely and the MDP's to be able to accept the CT's for power metering. 3 Shutdown and wiring modifications to MDP , TAL AMOUNT, Please fax signed acceptance to (39)

4 PR# 258 2/2/203 Crest Power/Data Additions (2) Data additions required for metering Crest include all data cable, ends, hangars, pipe and fasteners to run from Outside the Gym near the 200Amp service as directed, back to nearest Network room for Johnson Controls also half of the enclosure and heater material and labor. Included is pipe, fasteners, hangers, wiring and breakers needed for power circuit extensions from nearest 3- phase panel to outside the Gym near the 200 Amp service for metering panel and Johnson Control panel power requirements. Upsized CT's for larger service are included in power quote also half of the enclosure and heater labor and material. The cost for installing the Nema 2 enclosure and heater to house both panels, rail mounted heater and associated parts and wiring are split between the additional data and power quotes. The material and labor for each pipe run is included seperatley in each item of the quote. Data Additions - Option 2, Outside - LS , Power Additions - Option 2, Outside - LS , TAL AMOUNT 4, Please fax signed acceptance to (39)

5 The unforeseen condition related to Quote 297 could be analogous to finding a pipe in a wall that had extra offsets or corrosion that would require rework/replacement. We determine the approximate location of the pipe, but would not be able to know it s exact condition or routing. Specifically for the conductor terminations, covers would need to be removed from the live electrical equipment in order to view the conductors/bussing/terminals (or a planned shutdown would need to be coordinated). Our standard of care for site investigation does not include opening live electrical equipment as our Engineers do not have the appropriate training nor safety equipment. For the study phase of this project, we hired ACME Electric directly as we knew it was important to look inside of the 5kV cabinets and they have the equipment/training needed. For the metering scope of work on this project, it did not feel justifiable to add the expense of a licensed electrician to open panel covers as the conductors are generally trained in a manner where CT s can be installed. Specifically for this project, 7 of the 0 locations had conductors that were trained acceptably and fall within the scope of work for the original contract. Would you like for Design Engineers to adjust our standard of care for site work on electrical panels at Prairie? We discuss this topic with other Owners when issues like these come up and most become comfortable with the Engineer s educated assumptions as opposed to burdening the upfront cost of an electrician to open electrical equipment that many times aligns with the educated assumption.

COMMERCIAL HANDBOOK 2013 EDITION MATANUSKA ELECTRIC ASSOCIATION, INC. PALMER, ALASKA

COMMERCIAL HANDBOOK 2013 EDITION MATANUSKA ELECTRIC ASSOCIATION, INC. PALMER, ALASKA COMMERCIAL HANDBOOK 2013 EDITION MATANUSKA ELECTRIC ASSOCIATION, INC. PALMER, ALASKA ~ &teauea~. 'l«e. PtUt tjutee a'~ 2929 Pa/mete. Ata414 99645. ~~/7

More information

Installation and Construction Notes for EVSE4

Installation and Construction Notes for EVSE4 Installation and Construction Notes for EVSE4 You need to read and understand this if you want to build an EVSE that will be safe and need to pass a building inspectors review. Before beginning this process

More information

GENERAL INFORMATION 1.01 PURPOSE

GENERAL INFORMATION 1.01 PURPOSE GENERAL INFORMATION 1.01 PURPOSE The purpose of this manual is to supply essential information to customers, employees, architects, engineers, contractors, and others concerned with electrical installations

More information

OCEAN COUNTY ARES EMERGENCY GENERATOR USE By WX2NJ. The following was taken from September and October Ocean County ARES Newsletters in 2012:

OCEAN COUNTY ARES EMERGENCY GENERATOR USE By WX2NJ. The following was taken from September and October Ocean County ARES Newsletters in 2012: The following was taken from September and October Ocean County ARES Newsletters in 2012: I recently purchased a used 9KW dual-fuel (gasoline/propane) generator from a gentleman in Atlantic County, who

More information

Customer Requirements Downtown Secondary Network Service

Customer Requirements Downtown Secondary Network Service Application This standard describes the limitations and requirements for receiving service from the Tacoma Power secondary network system within the City of Tacoma downtown core area. In This Standard

More information

Electrical Safety Program

Electrical Safety Program Electrical Safety Program Medford Area Public School District 124 West State St School District: Medford, WI 54451 715 748 4620 Review Date(s): January 2018 Program Dave Makovsky Coordinator: Purpose and

More information

January 30, Ms. Safety Director Sample Medical Corp. PO Box X Somewhere, CT. Re: NFPA 70E Hazard Assessment. Date of Visit.

January 30, Ms. Safety Director Sample Medical Corp. PO Box X Somewhere, CT. Re: NFPA 70E Hazard Assessment. Date of Visit. 3018 Eastpoint Parkway Louisville, KY 40223 (502) 716-7073 January 30, 2006 Ms. Safety Director Sample Medical Corp. PO Box X Somewhere, CT Re: NFPA 70E Hazard Assessment Date of Visit January 24, 2006

More information

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards 1 General 1.1 Switchboards shall be U.L. listed and labeled. 1.2 Each switchboard shall have its own main disconnecting means unless it is located in the same room as its source of origin. In most cases

More information

Three-Phase Pole Mounted Recloser

Three-Phase Pole Mounted Recloser Three-Phase Pole Mounted Recloser Page 1 of 8 Table of Contents 1 GENERAL... 3 2 CONSTRUCTION... 3-5 3 BUSHINGS... 5 4 LINE CONNECTOR... 5 5 TOOLS....5 6 NAMEPLATES..6 7 PAINT... 6 8 EXTERNAL HARDWARE

More information

Schneider Electric Energy Solutions Savings Report. Florence City Schools

Schneider Electric Energy Solutions Savings Report. Florence City Schools Schneider Electric Energy Solutions Report Florence City Schools Prepared by: Performance Assurance Support Services 1650 West Crosby Road Carrollton, TX 75006 August 23, 2010 Executive Summary Following

More information

University of Houston Master Construction Specifications Insert Project Name

University of Houston Master Construction Specifications Insert Project Name SECTION 26 13 13 MEDIUM VOLTAGE SWITCHGEAR PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Divisions 0 and 1 and Section 26 00 01, Electrical General

More information

T&B Cable Tray. In this section...

T&B Cable Tray. In this section... In this section... T& Cable Tray T& Cable Tray Overview... -260-261 luminum Tray... -262-309 Steel Tray... -310-333 One-Piece Tray... -334-357 Channel Tray... -358-373 Common ccessories... -374-376 Grounding

More information

Energized Electrical Work

Energized Electrical Work Manitoba STANDARD PROCEDURE INSTRUCTION Title Energized Electrical Work Department Supersedes SPI Dated N/A SPI 32-4 Effective Date MAR 30, 2012 Energized Electrical Work SPI 32-4 Page 1 of 9 STANDARD

More information

Advanced Netbook Charging Carts for 10 laptops or 20 netbooks

Advanced Netbook Charging Carts for 10 laptops or 20 netbooks Advanced Netbook Charging Carts for 10 laptops or 20 netbooks Owners Manual TECHNOLOGY FURNITURE Hello! Thank you for choosing Anthro. This unit has been tested to Underwriters Laboratories U.S. and Canadian

More information

Eagle Mountain-Saginaw Independent School District REQUEST FOR COMPETITIVE SEALED PROPOSALS (RFCSP)

Eagle Mountain-Saginaw Independent School District REQUEST FOR COMPETITIVE SEALED PROPOSALS (RFCSP) Eagle Mountain-Saginaw Independent School District REQUEST FOR COMPETITIVE SEALED PROPOSALS (RFCSP) RFCSP Number: 1718-005-2023 RFCSP Title: Cabling Infrastructure Job Order Contract Due Date: February

More information

ELECTRICAL SAFETY-RELATED WORK PRACTICES

ELECTRICAL SAFETY-RELATED WORK PRACTICES ELECTRICAL SAFETY-RELATED WORK PRACTICES This checklist is provided to assist organizations in reviewing compliance with OSHA Standard 29 CFR 1910.331 through 1010.335. Refer to the complete Standard for

More information

10 Commercial, Industrial, Agricultural Services

10 Commercial, Industrial, Agricultural Services 10 Commercial, Industrial, Agricultural Services This section describes the Power Company requirements for commercial, industrial, and agricultural services. This section covers single phase and three

More information

Renewable Energy. Presented by Sean Flanagan

Renewable Energy. Presented by Sean Flanagan Renewable Energy Presented by Sean Flanagan Background Flanagan and Sun since 2004 Solar electric (PV) off grid and grid tie, solar thermal, pool heating, solar air heating, small wind turbines, microhydro

More information

Transmission and Distribution Substation Projects. Operating Company: Entergy Gulf States - Texas. Customer: PID # 202

Transmission and Distribution Substation Projects. Operating Company: Entergy Gulf States - Texas. Customer: PID # 202 Transmission and Distribution Substation Projects Operating Company: Entergy Gulf States - Texas Customer: PID # 202 Funding Project Number: F4PPGS0386 Facility Study for PID # 202: Study for 146 MW Revision

More information

METERING REQUIREMENTS

METERING REQUIREMENTS METERING REQUIREMENTS KUA will not accept a non-securable service trough entrance. That is, all enclosed conductors prior to the meter (line side) will be securable by and accessible to KUA personnel only.

More information

INSPECTION REQUIREMENTS: PHOTOVOLTAIC (PV) RESIDENTIAL

INSPECTION REQUIREMENTS: PHOTOVOLTAIC (PV) RESIDENTIAL Photovoltaic (PV) Residential Page 1 of 10 Revision Date: 07/18/2018 INSPECTION REQUIREMENTS: PHOTOVOLTAIC (PV) RESIDENTIAL INSPECTION CODE: 703 SCOPE: RESIDENTIAL APPLICABLE CODES: 2016 CBC, CRC, CPC,

More information

COMMERCIAL QUICK REFERENCE

COMMERCIAL QUICK REFERENCE COMMERCIAL QUICK REFERENCE PROVO CITY POWER STANDARDS ELECTRICAL ENGINEERING UPDATED: 2016 SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTIFICATION. 18" MIN. OF TAIL. (NEUTRAL CONDUCTOR MUST BE WHITE OR

More information

SERVICE REQUIREMENTS COMMERCIAL & INDUSTRIAL CUSTOMERS

SERVICE REQUIREMENTS COMMERCIAL & INDUSTRIAL CUSTOMERS ENERGY SERVICES ENGINEERING 840 Northgate Drive Telephone (509) 942-7403 Fax (509) 942-7405 P.O. Box 190 Richland, WA 99352 www.ci.richland.wa.us SERVICE REQUIREMENTS COMMERCIAL & INDUSTRIAL CUSTOMERS

More information

Is Your Wiring System Safe and Energy Efficient?

Is Your Wiring System Safe and Energy Efficient? 1 of 7 12/16/2010 1:27 PM University of Missouri Extension G1409, Reviewed October 1993 Is Your Wiring System Safe and Energy Efficient? Kenneth L. McFate and Fred M. Crawford Department of Agricultural

More information

Manual Transfer Switch

Manual Transfer Switch Manual Transfer Switch Instruction Manual 30 1200 Amp 2, 3 & 4 Pole Page 1 WARNING Before Installation READ THIS MANUAL carefully to learn how to properly install, operate and maintain this unit. Personal

More information

OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

OWNER S MANUAL AND INSTALLATION INSTRUCTIONS EmerGen Switch Manual Transfer Switch OWNER S MANUAL AND INSTALLATION INSTRUCTIONS For A Series Models 6-5001, 6-7501, 10-7501, 10-12K1 PLEASE READ THIS MANUAL IN ITS ENTIRETY BEFORE INSTALLING AND/OR

More information

DIN Rail Mounting Bracket

DIN Rail Mounting Bracket DIN Rail Mounting Bracket Fits Simpson Hawk 3, Falcon and Counters Fits Standard Din Rail C 1 4.30 2.55 3.85 Din Rail Adapter 44 Enclosure: Attachment Clips: Stiffeners: Installed depth: UL94V-0 Rated

More information

SUPPLEMENT MANUAL IM250. AQUAVAR CPC - FD Variable Speed Drive with Fused Disconnect SUPPLEMENT TO THE INSTALLATION AND OPERATION MANUAL (IM167)

SUPPLEMENT MANUAL IM250. AQUAVAR CPC - FD Variable Speed Drive with Fused Disconnect SUPPLEMENT TO THE INSTALLATION AND OPERATION MANUAL (IM167) SUPPLEMENT MANUAL IM250 AQUAVAR CPC - FD Variable Speed Drive with Fused Disconnect SUPPLEMENT TO THE INSTALLATION AND OPERATION MANUAL (IM167) TABLE OF CONTENTS SAFETY Use of Warnings and Notes...3 INSTALLATION

More information

Study Report. McCredie-Overton Transmission Line Right-of-Way Analysis. City of Columbia, Missouri. prepared for the (S49)

Study Report. McCredie-Overton Transmission Line Right-of-Way Analysis. City of Columbia, Missouri. prepared for the (S49) Study Report McCredie-Overton Transmission Line Right-of-Way Analysis prepared for the City of Columbia, Missouri (S49) May, 2017 S49 McCredie-Overton Transmission Line Right-of-Way Study Report Table

More information

PD404-AN V analog control 4 Channel x 500 W Dimmer & Switch Packs ANALOG 0-10 V. Serial Number

PD404-AN V analog control 4 Channel x 500 W Dimmer & Switch Packs ANALOG 0-10 V. Serial Number 0-10V analog control 4 Channel x 500 W Dimmer & Switch Packs ANALOG 0-10 V 4 circuit Analog 1-10V 4 x 4 A. Dimmer pack Serial Number Dimmers Indicators Digital Lighting Systems,Inc Info@digitallighting.com

More information

2006 Thermographic Inspection. Terrific Towers 1001 Sparks St Sydney. Vol. 9

2006 Thermographic Inspection. Terrific Towers 1001 Sparks St Sydney. Vol. 9 8/139 Woolooware Rd Burraneer NSW 2230 T. (02) 9544 3588 F. (02) 9544 3688 E. info@thermalimagingservices.com.au W. www.thermalimagingservices.com.au Accredited Thermographers 2006 Thermographic Inspection

More information

OPERATING MANUAL. aeration fans. models: sa sa sa SAFETY PRACTICES

OPERATING MANUAL. aeration fans. models: sa sa sa SAFETY PRACTICES 2237 MARSHALLTOWN BLVD. MARSHALLTOWN, IOWA 50158 PHONE: (641) 753-5601 TOLL FREE: 1-800-383-5601 FAX: (641) 752-9748 WWW.SPREAD-ALLMFG.NET OPERATING MANUAL aeration fans models: sa-12075 sa-12100 - sa-14100

More information

Circuit Concepts (Residential)

Circuit Concepts (Residential) Youth Explore Trades Skills Circuit Concepts (Residential) Description This Activity Plan will allow students to understand how electrical circuits work in a home. Students will also gain knowledge of

More information

WALL & STAND FANS CATALOG

WALL & STAND FANS CATALOG WALL & STAND FANS CATALOG 18 SEMI-INDUSTRIAL WALL AND STAND FANS Ideal for gyms, auditoriums, schools, churches and industrial spaces that need powerful air circulation PRODUCT INFORMATION Motor 3-speed,

More information

Application of Primary Fuses

Application of Primary Fuses Application of Primary Fuses Introduction The wide variety of fuse links offered by the A.B. Chance Company is instrumental in reducing the many problems facing today s coordination engineers. Besides

More information

CABINET - INSTRUMENT TRANSFORMER Indoor - Outdoor, 480 Volt Maximum 1200, 1600, 2000 Ampere

CABINET - INSTRUMENT TRANSFORMER Indoor - Outdoor, 480 Volt Maximum 1200, 1600, 2000 Ampere Printed from NIPSCO.com 04-01-17 PAGE 1 OF 6 USE: 1. For commercial and industrial installation, purchased and installed by the customer. 2. To enclose 600 volt insulation class instrument transformers

More information

UNDERGROUND SERVICE ENTRANCE LOCATION. No meter base or entrance should be installed before an KREMC engineer has checked the proposed location.

UNDERGROUND SERVICE ENTRANCE LOCATION. No meter base or entrance should be installed before an KREMC engineer has checked the proposed location. UNDERGROUND SERVICE No meter base or entrance should be installed before an KREMC engineer has checked the proposed location. Entrance cabinet must be directly through wall or directly under meter in basement.

More information

Statement of Work. 1.0 Executive Summary. 2.0 Features & Benefits. Modular Battery Replacement Service. Table of Contents

Statement of Work. 1.0 Executive Summary. 2.0 Features & Benefits. Modular Battery Replacement Service. Table of Contents Operate Statement of Work - 1 - Modular Battery Replacement Service Battery Service 1.0 Executive Summary Table of Contents 1.0 Executive Summary 2.0 Features & Benefits 3.0 Details of Service 4.0 Assumptions

More information

Electric & Gas Service Requirements (Greenbook) Overview

Electric & Gas Service Requirements (Greenbook) Overview INTRODUCTION The Greenbook contents and standard documents are updated regularly to provide users with the most current information possible. In conjunction with this effort, the 2016 Greenbook was reviewed

More information

New Panelboard for Lot H, EV Charger Energization, Las Positas College. Scope of Work and Technical Specifications

New Panelboard for Lot H, EV Charger Energization, Las Positas College. Scope of Work and Technical Specifications CHABOT-LAS POSITAS COMMUNITY COLLEGE DISTRICT New Panelboard for Lot H, EV Charger Energization, Las Positas College Scope of Work and Technical Specifications Chabot-Las Positas Community College District

More information

AC Wattmeters and VArmeters

AC Wattmeters and VArmeters AC Wattmeters and VArmeters The Crompton Instruments Switchboard series of AC Wattmeters and VArmeters incorporate a DC moving coil, pivot and jewel indicator with a micro-circuit watt transducer PCB to

More information

BUILDING PERMIT FEES BUILDING VALUATION DATA

BUILDING PERMIT FEES BUILDING VALUATION DATA BUILDING PERMIT FEES BUILDING VALUATION DATA The unit costs are intended to comply with the definition of "valuation" in Section 223 of the 1997 Uniform Building Code and thus include architectural, structural,

More information

Installation Instructions

Installation Instructions H3HK Series Installation Instructions Large Package Electric Heater Kits Description Installation of 208/240V H3HK Heater Kits in Packaged Air Conditioners and Packaged Heat Pumps. These instructions are

More information

CITY OF LOMPOC UTILITIES DEPARTMENT ELECTRICAL DIVISION SPECIFICATION NO. ELE-112 SUBSTATION CLASS VACUUM CIRCUIT BREAKERS OCTOBER 2008

CITY OF LOMPOC UTILITIES DEPARTMENT ELECTRICAL DIVISION SPECIFICATION NO. ELE-112 SUBSTATION CLASS VACUUM CIRCUIT BREAKERS OCTOBER 2008 CITY OF LOMPOC UTILITIES DEPARTMENT ELECTRICAL DIVISION SPECIFICATION NO. ELE-112 SUBSTATION CLASS VACUUM CIRCUIT BREAKERS OCTOBER 2008 SPECIFICATION NO: ELE_112_R1.doc Page 1 of 3 Rev. 10/28/2008 SPECIFICATION

More information

Service Bulletin Published by Sudden Service, Inc.

Service Bulletin Published by Sudden Service, Inc. Service Bulletin Published by Sudden Service, Inc. Volume 09 / Number 3 / May 15, 2009 Louisville, Mississippi Pre-operational checks of the MM80 Pack-Rat should be performed before each use in order to

More information

Home Electrical Wiring. Getting the electricity from the main power lines to a location in the house

Home Electrical Wiring. Getting the electricity from the main power lines to a location in the house Home Electrical Wiring Getting the electricity from the main power lines to a location in the house 90% of BC power comes from Hydro There is potential energy stored in a water reservoir behind a dam.

More information

UNIVERSITY OF TOLEDO PVIC SOLAR ARRAY MODIFICATIONS

UNIVERSITY OF TOLEDO PVIC SOLAR ARRAY MODIFICATIONS 1 UNIVERSITY OF TOLEDO PVIC SOLAR ARRAY MODIFICATIONS June 27, 2013 Prepared by Ted Davis and Randy Ellingson 2 Current Configuration Array #2 wired for the electrolyzer as follows: All 108 panels are

More information

OPERATING MANUAL. centrifugal fan SAFETY PRACTICES

OPERATING MANUAL. centrifugal fan SAFETY PRACTICES 2237 MARSHALLTOWN BLVD. MARSHALLTOWN, IOWA 50158 PHONE: (641) 753-5601 TOLL FREE: 1-800-383-5601 FAX: (641) 752-9748 WWW.SPREAD-ALLMFG.NET OPERATING MANUAL centrifugal fan SAFETY PRACTICES 1. Have a qualified

More information

MEDIUM VOLTAGE PRODUCT CAPABILITIES OVERVIEW

MEDIUM VOLTAGE PRODUCT CAPABILITIES OVERVIEW MEDIUM VOLTAGE PRODUCT CAPABILITIES OVERVIEW Medium Voltage Product Overview MVB SERIES, MEDIUM VOLTAGE DRAW-OUT CIRCUIT BREAKER MVB SERIES Standard Breaker Features : 1200, 2000, 3000 Amps, 3 phase, 60

More information

Continuing Education Course #206 Introduction to Designing Machine Control Systems Part 2

Continuing Education Course #206 Introduction to Designing Machine Control Systems Part 2 1 of 5 Continuing Education Course #206 Introduction to Designing Machine Control Systems Part 2 1. Continuing to answer the following questions indicates that you understands that the presented material

More information

SECTION CENTRIFUGAL HVAC FANS

SECTION CENTRIFUGAL HVAC FANS SECTION 233416 - CENTRIFUGAL HVAC FANS 1. PART 1 GENERAL 1.1. RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

ANSI Switchboard Meters

ANSI Switchboard Meters ANSI Switchboard Meters High quality range of switchboard instruments with Class 1 accuracy and which complies with American ANSI-C39.1 (1981) specifications. Available in 4 1 /2" case size, the rugged

More information

ACCESSORY KIT INSTALLATION INSTRUCTIONS

ACCESSORY KIT INSTALLATION INSTRUCTIONS ACCESSORY KIT INSTALLATION INSTRUCTIONS Low Ambient Accessory For Air Cooled Split-System Air Conditioners YD360/480/600, YJ-30/-40/-50 and J30/40/50 YD Models 642546-UAI-A-080 GENERAL Standard operation

More information

NORTH CAROLINA SHERIFFS ASSOCIATION

NORTH CAROLINA SHERIFFS ASSOCIATION NORTH CAROLINA SHERIFFS ASSOCIATION Name of Dealership Type of Vehicle Zone 600 AMP AUTOMATIC TRANSFER SWITCH (Specification #07) Base Unit Price 207 ASCO AC600 Appalachia -- NB -- 207 ASCO AC600 Dogwood

More information

SECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT

SECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT SECTION 16400 LOW VOLTAGE DISTRIBUTION EQUIPMENT A. General 1. The University does not accept Series-Rated equipment for power distribution switchboards, distribution panels and branch circuit panelboards.

More information

UNDERGROUND SERVICE ENTRANCE LOCATION. No meter base or entrance should be installed before an KREMC engineer has checked the proposed location.

UNDERGROUND SERVICE ENTRANCE LOCATION. No meter base or entrance should be installed before an KREMC engineer has checked the proposed location. UNDERGROUND SERVICE No meter base or entrance should be installed before an KREMC engineer has checked the proposed location. Entrance cabinet must be directly through wall or directly under meter in basement.

More information

A Cost Benefit Analysis of Faster Transmission System Protection Schemes and Ground Grid Design

A Cost Benefit Analysis of Faster Transmission System Protection Schemes and Ground Grid Design A Cost Benefit Analysis of Faster Transmission System Protection Schemes and Ground Grid Design Presented at the 2018 Transmission and Substation Design and Operation Symposium Revision presented at the

More information

Easy/Tran TF STANDBY POWER FURNACE SWITCH TOOLS NEEDED FOR INSTALLATION. PARTS LIST for Easy / Tran TF FURNACE TRANSFER SWITCH

Easy/Tran TF STANDBY POWER FURNACE SWITCH TOOLS NEEDED FOR INSTALLATION. PARTS LIST for Easy / Tran TF FURNACE TRANSFER SWITCH STANDBY POWER FURNACE SWITCH Easy/Tran TF Congratulations on your purchase of the Reliance Controls Easy/Tran TF furnace transfer switch. Reliance has been manufacturing transfer switches and equipment

More information

THE CARMONY BUILDING ELECTRICAL SYMBOLS AND ABBREVIATIONS NOT ALL SYMBOLS, DEVICES OR ABBREVIATIONS MAY BE USED ELECTRICAL SYMBOLS AND ABBREVIATIONS

THE CARMONY BUILDING ELECTRICAL SYMBOLS AND ABBREVIATIONS NOT ALL SYMBOLS, DEVICES OR ABBREVIATIONS MAY BE USED ELECTRICAL SYMBOLS AND ABBREVIATIONS LIGHTING ELECTRICAL SYMBOLS AND ABBREVIATIONS ABBREVIATIONS ELECTRICAL GENERAL NOTES EQUIPMENT POWER DEVICES NOT ALL SYMBOLS, DEVICES OR ABBREVIATIONS MAY BE USED LINE TYPE LEGEND CIRCUITS TELECOMMUNICATION

More information

How to Cut Costs in Transportation

How to Cut Costs in Transportation 1 How to Cut Costs in Transportation OSBA leads the way to educational excellence by serving Ohio s public school board members and the diverse districts they represent through superior service, unwavering

More information

SPECIFICATIONS OXYMAX SUB-SURFACE AERATION SYSTEM

SPECIFICATIONS OXYMAX SUB-SURFACE AERATION SYSTEM SPECIFICATIONS OXYMAX SUB-SURFACE AERATION SYSTEM 1.0 GENERAL 1.1 DESCRIPTION A. Manufacturer shall furnish an aeration system capable of providing more equal distribution of oxygenated water throughout

More information

OFFICE PARTITIONS. Data Port Openings. Use cable tie bracket to dress data cables under panels. STEP 1

OFFICE PARTITIONS. Data Port Openings. Use cable tie bracket to dress data cables under panels. STEP 1 N Power Box Opening Data Port Openings Rear View Front View Remove opening blanks on raceway cover for power and data. If panel contains no electric or data and is used as a pass-thru, leave opening blanks

More information

CT Metering. CT Metering. Meter Mounting Equipment

CT Metering. CT Metering. Meter Mounting Equipment Single Meter Sockets, Without Bypass - CT Rated.................................. 67-68 Single Meter Sockets, CT Rated With Test Switch Bypass Provision............. 69-70 Meter Socket / Enclosure Combination

More information

WARREN COUNTY, N.Y. M/E REFERENCE

WARREN COUNTY, N.Y. M/E REFERENCE SECTION 262000 - ELECTRIC DISTRIBUTION PART 1 - GENERAL 1.1 DESCRIPTION A. Provide a complete secondary distribution system as indicated on the Contract Documents and as specified herein. 1.2 QUALITY ASSURANCE

More information

BP OIL -- TOLEDO REFINERY

BP OIL -- TOLEDO REFINERY BP OIL -- TOLEDO REFINERY Document Type: Procedure Effective Date: August 31, 2017 Owner: Dane P. Clark Refinery Wide Electrical Distribution System Switching and Isolation Auth. By: Rick J. Chmelovski

More information

Engineering Instruction

Engineering Instruction Engineering Instruction Electrical Distribution Unit Approved by: Lidija Dumbaloska, Professional Head Electrical Engineering, Sydney Trains Authorised by: Jonathon McKinnon, Engineering Technical Publications

More information

Joslyn Clark Controls, Inc. Simple, Safe, Retrofit Programs to Significantly Extend Life of Existing Circuit Breakers

Joslyn Clark Controls, Inc. Simple, Safe, Retrofit Programs to Significantly Extend Life of Existing Circuit Breakers Joslyn Clark Controls, Inc. Simple, Safe, Retrofit Programs to Significantly Extend Life of Existing Circuit Breakers 2 Introduction This discussion describes in detail retrofitting medium voltage circuit

More information

Power/Vac Switchgear Concepts And Basic Configurations

Power/Vac Switchgear Concepts And Basic Configurations Contents Section 1 Section 1 Power/Vac Switchgear Concepts And Basic Configurations Page USE OF APPLICATION GUIDE... 1-2 Power/Vac METALCLAD SWITCHGEAR... 1-2 SWITCHGEAR STANDARDS... 1-4 TWO-TIER BREAKER

More information

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE PAGE 261116-1 SECTION 261116 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

Assessing a Site for Installation of Consumption Monitoring

Assessing a Site for Installation of Consumption Monitoring TECHNICAL BRIEF Assessing a Site for Installation of Consumption Monitoring About the Enphase Envoy-S Metered The Enphase Envoy-S Metered communications gateway enables performance monitoring and remote

More information

AFTER GAZETTING (WORKING DOCUMENT FOR A 3 YEAR PERIOD) DATE PAGE PARAGRAPH DESCRIPTION ORIGINATOR APPROVED

AFTER GAZETTING (WORKING DOCUMENT FOR A 3 YEAR PERIOD) DATE PAGE PARAGRAPH DESCRIPTION ORIGINATOR APPROVED PART B-07 TITLE: SERVICE CONNECTIONS SPECIFICTION NO: B-07 INCEPTION DATE: AFTER GAZETTING (WORKING DOCUMENT FOR A 3 YEAR PERIOD) AMENDMENTS / REVISIONS DATE PAGE PARAGRAPH DESCRIPTION ORIGINATOR APPROVED

More information

SENATE, No STATE OF NEW JERSEY. 217th LEGISLATURE INTRODUCED JUNE 27, 2016

SENATE, No STATE OF NEW JERSEY. 217th LEGISLATURE INTRODUCED JUNE 27, 2016 SENATE, No. STATE OF NEW JERSEY th LEGISLATURE INTRODUCED JUNE, 0 Sponsored by: Senator RONALD L. RICE District (Essex) SYNOPSIS Establishes For-Hire Vehicle License Plate Task Force; requires issuance

More information

1 INTRODUCTION SPECIFICATIONS Electrical Data General Data... 3

1 INTRODUCTION SPECIFICATIONS Electrical Data General Data... 3 International Electrical Symbols Caution! Refer to this manual before using the probe Probe is protected by Reinforced or Double Insulation CONTENTS Page 1 INTRODUCTION... 2 2 SPECIFICATIONS... 2 2.1 Electrical

More information

MOTOR SURVEY. Solutions for Industry

MOTOR SURVEY. Solutions for Industry In the United States, motors consume almost of 70 percent of the electricity used by industry, which translates to more than $30 billion in annual cost. This is why implementing even small improvements

More information

LLC FACILITIES STUDY TRANSMISSION SERVICE REQUEST

LLC FACILITIES STUDY TRANSMISSION SERVICE REQUEST Cleco Power LLC FACILITIES STUDY TRANSMISSION SERVICE REQUEST OASIS 71956063 0 Rev Issue Date Description of Revision Table of Contents 1. Purpose...3 2. System Impact Study Conclusions...3 2.1 The Pineville

More information

PID 274 Feasibility Study Report 13.7 MW Distribution Inter-Connection Buras Substation

PID 274 Feasibility Study Report 13.7 MW Distribution Inter-Connection Buras Substation PID 274 Feasibility Study Report 13.7 MW Distribution Inter-Connection Buras Substation Prepared by: Entergy Services, Inc. T & D Planning L-ENT-17A 639 Loyola Avenue New Orleans, LA 70113 Rev Issue Date

More information

Outdoor Nema Enclosure For Dotworkz CoolDome Power Supply Product Code: NM-CDPS. User Manual

Outdoor Nema Enclosure For Dotworkz CoolDome Power Supply Product Code: NM-CDPS. User Manual Outdoor Nema Enclosure For Dotworkz CoolDome Power Supply Product Code: NM-CDPS User Manual Revision June 2008 Outdoor Nema Enclosure For Dotworkz CoolDome Power Supply LIMITED WARRANTY FOR DOTWORKZ SYSTEMS

More information

EasyStart 364 (ASY-364-X20-IP) Installation Instructions for the Coleman / Airxcel Air Conditioners

EasyStart 364 (ASY-364-X20-IP) Installation Instructions for the Coleman / Airxcel Air Conditioners EasyStart 364 (ASY-364-X20-IP) Installation Instructions for the Coleman / Airxcel Air Conditioners using Installation Kit KIT-364-CM1 Contents Introduction... 2 Safety first... 2 Making a good crimp...

More information

TruckStop Express INSTALLATION MANUAL

TruckStop Express INSTALLATION MANUAL TruckStop Express INSTALLATION MANUAL April 2012 Cutting edge simplicity Table of Contents Introduction... 4 Warranty... 4 Specifications... 5 Guidelines... 6 Controller Wiring... 8 Electric Engines...

More information

SPECIFICATIONS ULTIMAX SUB-SURFACE DIRECTIONAL AERATION SYSTEM

SPECIFICATIONS ULTIMAX SUB-SURFACE DIRECTIONAL AERATION SYSTEM SPECIFICATIONS ULTIMAX SUB-SURFACE DIRECTIONAL AERATION SYSTEM 1.0 GENERAL 1.1 DESCRIPTION A. Manufacturer shall furnish an aspirating directional aerator (aspirator) or a high-flow directional aerator

More information

Mechanical, Electrical, Technology Engineering Firm

Mechanical, Electrical, Technology Engineering Firm Mechanical, Electrical, Technology Engineering Firm Established 1995 Current staff of forty-five Twenty engineers (12 registered P.E. s) Three Registered Communications Distribution Designers - RCDD s

More information

Pretest Module 24 Three-phase Service Entrance

Pretest Module 24 Three-phase Service Entrance Pretest Module 24 Three-phase Service Entrance 1. What is the most widely used three-phase service entrance system? 2. What are the three most common voltage combinations for three-phase, four-wire systems?

More information

APPENDIX 3 EXTRACTS FROM THE NEW ZEALAND ELECTRICAL CODE OF PRACTICE FOR ELECTRICAL SAFE DISTANCES (NZECP 34:2001)

APPENDIX 3 EXTRACTS FROM THE NEW ZEALAND ELECTRICAL CODE OF PRACTICE FOR ELECTRICAL SAFE DISTANCES (NZECP 34:2001) APPENDIX 3 EXTRACTS FROM THE NEW ZEALAND ELECTRICAL CODE OF PRACTICE FOR ELECTRICAL SAFE DISTANCES (NZECP 34:2001) SECTION 2 MINIMUM SAFE DISTANCES FOR EXCAVATION AND CONSTRUCTION NEAR OVERHEAD ELECTRIC

More information

User s Guide. Includes Mounting, Installation, and Product Registration

User s Guide. Includes Mounting, Installation, and Product Registration User s Guide Includes Mounting, Installation, and Product Registration 500 OutBack Power Systems FLEXware is a system of modular aluminum mounting hardware and installation components designed for convenient

More information

What's New with UL508A Codes & Standards Presented by Jeff Woolfolk Manufacturing in America March 14-15, 2018

What's New with UL508A Codes & Standards Presented by Jeff Woolfolk Manufacturing in America March 14-15, 2018 What's New with UL508A Codes & Standards Presented by Jeff Woolfolk Manufacturing in America March 14-15, 2018 Before we start A Penny for Your Thoughts At the end of the session, share your feedback via

More information

Service Bulletin Published by Sudden Service, Inc.

Service Bulletin Published by Sudden Service, Inc. Service Bulletin Published by Sudden Service, Inc. Volume 07 / Number 3 / June 13, 2007 Louisville, Mississippi Electrical System Maintenance Requirements Taylor Machine Works, Inc. has developed electrical

More information

Woda-Sci System Installation Parts Set

Woda-Sci System Installation Parts Set Installation Manual Woda-Sci System Installation Parts Set 5/32 x 3 ½ Drill Bit - 5 Connector Body - 7 3/8 Locking Nut - 8 3/16 x 1 ¼ Concrete Anchors- 4 Mounting Screws - 3 Stainless Steel Hanger - 9

More information

Town of Holliston Board of Selectmen 703 Washington Street Holliston, MA 01746

Town of Holliston Board of Selectmen 703 Washington Street Holliston, MA 01746 of Holliston Board of Selectmen 703 Washington Street Holliston, MA 01746 of Holliston Green Community 1 st Quarter Progress Report September 30, 2017 The of Holliston Green Community Team has been hard

More information

Watauga County Schools Capital Improvement Plan 2015

Watauga County Schools Capital Improvement Plan 2015 Watauga County Schools Capital Improvement Plan 2015 WATAUGA COUNTY SCHOOLS CAPITAL IMPROVEMENT PLAN 2015 In an effort to meet the standards of the North Carolina Building Code and North Carolina Public

More information

Fort Bend ISD Fire Origin and Cause 3130 Lake Olympia Parkway Missouri City, TX Client File: COMP Haag File:

Fort Bend ISD Fire Origin and Cause 3130 Lake Olympia Parkway Missouri City, TX Client File: COMP Haag File: This document has been electronically signed and/or sealed in accordance with the applicable State Board of Professional Engineering requirements. Fort Bend ISD Fire Origin and Cause 3130 Lake Olympia

More information

Catalog Air Terminal Units. Models MQTH, MQFCI and MQFVI. Model MQTH. Model MQFCI. Model MQFVI

Catalog Air Terminal Units. Models MQTH, MQFCI and MQFVI. Model MQTH. Model MQFCI. Model MQFVI Air Terminal Units Models MQTH, MQFCI and MQFVI Catalog 903-1 Model MQTH Model MQFCI Model MQFVI Table of Contents Single Duct Air Terminal Units.... 3 Introduction....3 MQTH-500 Single Duct Air Terminal

More information

Busway Construction. Bus Bars

Busway Construction. Bus Bars Busway Construction Bus Bars A better understanding of what busway is can be gained by examining its construction. A typical Siemens Sentron busway section has three or four formed aluminum or copper bars

More information

Cold Spring School District 2243 Sycamore Canyon Road, Santa Barbara, CA (805)

Cold Spring School District 2243 Sycamore Canyon Road, Santa Barbara, CA (805) Cold Spring School District 2243 Sycamore Canyon Road, Santa Barbara, CA 93108 (805) 969-2678 Notice of Invitation for Informal Bids Pursuant to California Uniform Public Construction Cost Accounting Procedures

More information

Application note. The APM-AMP meter can be connected in three different configurations:

Application note. The APM-AMP meter can be connected in three different configurations: Application note Title: Current sensing with an APM-AMP meter Date: 5 th September 2014 Revision: 1.0 Introduction: The APM-AMP meter can measure both AC and DC currents. The APM-AMP meter performs automatic

More information

BLUE 3 INSTALLATION GUIDE

BLUE 3 INSTALLATION GUIDE BLUE 3 INSTALLATION GUIDE CATCH Power BLUE 3 Installation manual - Page 1 IMPORTANT This product must be installed by a licensed electrician. This product must be installed according to the AS3000 Australian

More information

OTAHUHU-MANGERE-ROSKILL- HEPBURN ROAD 110 KV CIRCUITS

OTAHUHU-MANGERE-ROSKILL- HEPBURN ROAD 110 KV CIRCUITS NORTH AUCKLAND AND NORTHLAND GRID UPGRADE PROJECT ATTACHMENT J OTAHUHU-MANGERE-ROSKILL- HEPBURN ROAD 110 KV CIRCUITS UPGRADE WITH HIGH TEMPERATURE LOW SAG CONDUCTOR September 2007 Contents 1 INTRODUCTION

More information

TECHNICAL SPECIFICATION FOR A 10 TO 50 KVA THREE PHASE, UNINTERRUPTIBLE POWER SYSTEM WaveRider III

TECHNICAL SPECIFICATION FOR A 10 TO 50 KVA THREE PHASE, UNINTERRUPTIBLE POWER SYSTEM WaveRider III TECHNICAL SPECIFICATION FOR A 10 TO 50 KVA THREE PHASE, UNINTERRUPTIBLE POWER SYSTEM WaveRider III 1. SCOPE A. The Central Lighting Inverter shall be a solid-state three phase system designed to provide

More information

LEV/Wn Building A Connected World

LEV/Wn Building A Connected World LEV/Wn Building A Connected World PK-93370-10-00-2B Installing and Testing a GFCI Please read this leaflet completely before getting started. A CAUTION To prevent severe shock or electrocution always turn

More information

TABLE OF CONTENTS. Important Notices Underground Plant Protection Information. Commercial/Industrial Information Sheet

TABLE OF CONTENTS. Important Notices Underground Plant Protection Information. Commercial/Industrial Information Sheet DRAWING NUMBER INTRODUCTORY INFORMATION Important Notices Underground Plant Protection Information Code Clearances Commercial/Industrial Information Sheet Work Management Customer Projects Engineering

More information

EV Charging Station Submittal Requirements

EV Charging Station Submittal Requirements EV Charging Station Submittal Requirements To obtain a permit for an Electric Vehicle Charging Station, please provide the following: Plan and details of the charging system installation o Print applicable