1 INTRODUCTION SPECIFICATIONS Electrical Data General Data... 3
|
|
- Catherine Anderson
- 5 years ago
- Views:
Transcription
1 International Electrical Symbols Caution! Refer to this manual before using the probe Probe is protected by Reinforced or Double Insulation CONTENTS Page 1 INTRODUCTION SPECIFICATIONS Electrical Data General Data OPERATING INSTRUCTIONS Switch On Zero Adjustment Auto Off Current Measurement SAFETY BATTERY REPLACEMENT WARRANTY OTHER PRODUCTS Issue 1. 19/06/01
2 1. INTRODUCTION The PR630 and the PR1530 current probes have been designed for use with oscilloscopes, recorders and other suitable equipment for accurate non-intrusive measurement of AC, DC and complex waveform currents. Using advanced Hall Effect technology, the PR630 can accurately measure currents up to 600 A r.m.s. over the frequency range of DC to 20 khz, while the PR1530 measures currents up to 1500A DC or AC r.m.s.. These features make them powerful tools for use in inverters, switch mode power supplies, industrial controllers, automotive diagnostics and other applications requiring accurate isolated current measurement. 2. SPECIFICATION 2.1. Electrical data (All accuracies stated at 23 C ± 1 C) Current ranges PR PR Overload capacity % 2 60A and 600A DC and AC r.m.s. (85A and 850A peak) 150A and 1500A DC and AC r.m.s. (220A and 2200A peak) Accuracy with conductor at the centre of the aperture PR630, 60A range... ± 1% of rdg ± 0.1 A PR630, 600A range... ± 1% of rdg ± 0.5 A PR1530, 150A range... ± 1% of rdg ± 0.1 A PR1530, 1500A range. ± 1% of rdg ± 0.5 A Error due to the position of the conductor ± 1% relative to the centre reading. Resolution PR630, 60A range... PR630, 600A range... PR1530, 150A range... PR1530, 1500A range. Temperature coefficient... Output sensitivity PR630, 60A range... PR630, 600A range... PR1530, 150A range... PR1530, 1500A range. ± 100 ma ± 100 ma ± 100 ma ± 100 ma ± 0.1% of reading / C 10 mv/a 1 mv/a 10 mv/a 1 mv/a
3 3
4 Frequency range ( -3dB) DC to 20 khz (small signal) (limited by eddy current heating for I rms x f > 400,000) Phase shift below 1kHz < ± 2 Dielectric strength General data Operating temperature... Storage temperature with battery removed... Power supply... Battery life... Auto Switch Off... Load impedance... Conductor size PR PR Jaw opening PR PR Weight 5550 V r.m.s. 50 Hz for 1 min IEC1010, Cat III, 600V, Pollution Degree 2-10 C to +60 C - 20 C to +85 C 9 V, Alkaline battery PP3, NEDA 1604 or IEC6F22 50 hours typical 30 minutes typical > 10 kω and 100pF 35 mm 50 mm 40 mm max. 55 mm max. PR g. PR g. Output cable and connector... 2m long RG58 cable terminated with an insulated BNC connector 4
5 3. OPERATING INSTRUCTIONS Refer to Fig. 1 for the PR630 and Fig. 2 for the PR Switch On When the probe is switched on the red LED will illuminate. If the red LED starts flashing this warns the user that the battery voltage is too low for normal operation and that it should be changed as described in section DC Zero Adjustment The output zero offset voltage of the probe may change due to thermal shifts and other environmental conditions. To adjust the output voltage to zero depress the DC zero button. Ensure that the probe is away from the current carrying conductor and with the jaws closed whilst the adjustment is made Auto Off The probe has an auto power off feature which switches the probe off 30 minutes after the probe has been switched on. When switched off by this method, the switch must be set to the off position before being switched on again. This function can be disabled (for logging applications or similar) by setting the slide switch in the battery compartment to the Off position. To remove the battery cover refer to section 5 Battery Replacement. When the Auto Off function is enabled the green LED will be lit Current Measurement Switch on the probe using the On - Off switch and check that the red LED is lit. Select the required current range (60 Amp or 600 Amp PR630 or 150 Amp or 1500 Amp - PR1530). Connect the output lead to an oscilloscope, multimeter or any other measuring equipment. If necessary, adjust the probe output voltage to zero as described in section 3.2. Clamp the jaws of the probe around the conductor ensuring a good contact between the closing faces of the jaws. Observe and take measurements as required. Positive output indicates that the current flow is in the direction shown by the arrow on the probe. Core eddy current heating is produced when I rms x f > 400,000. 5
6 AC DC 600A 60A OFF AUTO OFF CURRENT 60A-10mV/A 600A-1mV/A DC ZERO O N PROBE 600A PR630 PR630 Fig 1 1. Power LED (Red) 2. Auto Off LED (green) 3. ON / OFF Switch 4. Protective Barrier 5. Jaws 6
7 PR1530 AC DC 1500A 1500A 150A OFF AUTO OFF DC ZERO ON CURRENT PROBE 150A-10mV/A 1500A-1mV/A PR1530 Fig.2 1. Power LED (Red) 2. Auto Off LED (green) 3. ON / OFF Switch 4. Protective Barrier 5. Jaws 7
8 4. SAFETY This product conforms to the latest directives concerning safety and electromagnetic compatibility. European Low Voltage Directives 73/23/EEC and 93/68/EEC European EMC Directives 89/336/EEC and 93/68/EEC Safety Standards IEC : Safety requirements for electrical equipment for measurement, control and laboratory use. Part 2-032: 1995 Particular requirements for hand held current clamps for electrical measurement and test. Part 2-031: 1995 Particular requirements for hand held probe assemblies for electrical measurement and test. 600V Cat III Pollution degree 2 EMC Standards RF Susceptibility EN 61326: 1998 Electrical equipment for measurement, control and laboratory use, Criteria B. RF Emissions EN 61326: 1998 Electrical equipment for measurement, control and laboratory use. FCC Part 15 Class B This product is designed to be safe under the following conditions: - indoor use - altitude up to 2000 m - temperature 0 C to +50 C - maximum relative humidity 80% for temperatures up to 31 C decreasing linearly to 40% relative humidity at 50 C. Use of the probe on uninsulated conductors is limited to 600 V r.m.s or D.C. and frequencies below 1kHz. Safety in its use is the responsibility of the operator who must be a suitably qualified or authorised person. Do not use the probe if any part of the probe including the lead and connector appear to be damaged or if a malfunction of the instrument is suspected. When using the probe ensure that your fingers are behind the protective barrier see Fig. 1 or Fig. 2. 8
9 Clean the case periodically by wiping it with a damp cloth and detergent. Do not use abrasive cleaners or solvents. Do not immerse the probe in liquids. 5. BATTERY REPLACEMENT The red LED will flash when the minimum operating voltage is approached. Refer to Fig.3. use the following procedure. Unclamp the probe from the conductor, turn it off using the On - Off switch and disconnect the output lead, from external equipment. Loosen the captive screw which secures the battery cover. Lift the cover through 30 and pull it clear of the probe body as shown in Fig 3. The battery is then accessible. Replace the battery and re-fit the battery cover and fasten the screw. Replacement with other than the specified type of battery will invalidate the warranty. Fit only Type 9 V PP3, Alkaline (MN 1604). SAFETY WARNING Before removing the battery cover, make sure that the probe is remote from any live electrical circuit. Fig 3 Battery Replacement 9
10 6. WARRANTY Your LEM HEME current probe is guaranteed for two years from the date of purchase against defective material or workmanship. If the probe fails during the warranty period, we shall at our discretion, repair or replace it with a new or reconditioned unit provided we are satisfied that the failure is due to defective material or workmanship. To make a claim under warranty, the probe should be returned to us, postage prepaid, with a description of the defect. The use of a battery, other than that specified invalidates this warranty. Goods alleged by the buyer to be defective shall not form the subject of any claim for injury, loss, damage, or any expense howsoever incurred whether arising directly or indirectly from such alleged defects other than death or personal injury resulting from the seller s negligence. No condition is made or to be implied nor is any warranty given or to be implied as to the life or wear of goods supplied or that they will be suitable for any particular purpose or for use under specific conditions, notwithstanding that such purpose or conditions may be made known to the seller. 10
11 7. OTHER PRODUCTS LEM offers a comprehensive range of electrical test products to ensure the safe and efficient operation of electrical equipment and installations including: Earth/ground testers: Installation testers: Insulation testers: Clamp-on meters: Multimeters Current probes: HANDY GEO, SATURN GEO, UNILAP GEO (X) SATURN 100, UNILAP 100 (X)E HANDY ISO, SATURN ISO, UNILAP ISO X, UNILAP ISO 5 kv LH Series and Analyst 2050/60...Unigor Series PR Series and LEM~Flex Other products from the LEM group include systems and analysers for power and power quality monitoring and transducers for current and voltage measurement. LEM provides complete measurement solutions in current, voltage and power quality - please, contact our sales partners world-wide for more information. For further information also, please refer to the LEM website:- LEM policy is one of continuous product improvement and the company reserves the right to revise the above specifications without prior notice. 11
12 Gain in db Typical Frequency Response PR630 (60A range) Typical Frequency Response PR630 (60A range) Phase Shift in Degrees Gain in db Phase Shift in Degrees Typical Frequency Response PR630 (600A range) Typical Frequency Response PR630 (600A range)
13 Gain in db Typical Frequency Response PR1530 (150A range) Typical Frequency Response PR1530 (150A range) Phase Shift in Degrees Gain in db Phase Shift in Degrees Typical Frequency Response PR1530 (1500A range) Typical Frequency Response PR1530 (1500A range)
14
15
CP GermanCp 41_CP C. Operating Instructions. CP 30 CP 330 CP 1100 AC/DC current probe /7.10
CP 30 35 GermanCp 41_CP C Operating Instructions CP 30 CP 330 CP 1100 AC/DC current probe 3-349-600-37 1/7.10 Order Reference CP 30 CP 330 CP 1100 Order No. Z201B Z202B Z203B Battery is included. Thank
More informationLH41A. User Manual. Clamp On Ammeter. For detailed specifications and ordering info go to
LH41A Clamp On Ammeter User Manual For detailed specifications and ordering info go to www.testequipmentdepot.com LH41A Clamp On Ammeter Users Manual English April 2007, Rev.2 2007 Amprobe Test Tools.
More informationR&S RT-ZC02 R&S RT-ZC03 AC/DC Current Probe User Manual
R&S RT-ZC02 R&S RT-ZC03 AC/DC Current Probe User Manual / User Manual Content 1 Introduction 3 2 Safety 3 3 Specifications RT-ZC03 6 Specifications RT-ZC02 7 4 Operating Instructions RT-ZC03 8 Operating
More informationLEM~flex RR3020 AC Current Probe Operating Instructions Mode d emploi Bedienungshandbuch Manuale Operativo Manual de uso
LEM~flex RR3020 AC Current Probe Operating Instructions Mode d emploi Bedienungshandbuch Manuale Operativo Manual de uso Table of Contents Order Reference Order No. LEM~flex Type RR3020 AC Current Probe...
More informationLow Amp Probe EETA308A
Low Amp Probe EETA308A Reference Manual First Edition SAFETY WARNING DO NOT APPLY OVER 150V AC (RMS) OR DC. DISCONNECT LEADS BEFORE REMOVING THE BATTERY COVER. DO NOT ALLOW THE CABLE TO BECOME ENTANGLED
More informationAC/DC CURRENT TRANSDUCER 600A 10mV/1A, 1mV/1A
AC/DC CURRENT TRANSDUCER 600A 10mV/1A, 1mV/1A INTRODUCTION 1-1 Unpacking and Inspection Upon removing your new Current Transducer from its packing, you should have the following items: 1. Current Transducer
More informationAC/DC CURRENT TRANSDUCER INSTRUCTION MANUAL
AC/DC CURRENT TRANSDUCER INSTRUCTION MANUAL INTRODUCTION 1-1 Unpacking and Inspection Upon removing your new Clamp Meter from its packing, you should have the following items: 1. Current Transducer with
More informationThe following table shows the symbols used on the product and/or in this manual. Hazardous Voltage. Risk of electric shock.
i6000s Flex AC Current Probe Instruction Sheet Introduction The i6000s 24 Flex and i6000s 36 Flex AC Current Probes (hereafter referred to as the Probes ) are used with oscilloscopes, digital multimeters,
More informationi3000s/i2000 Flex AC Current Probe
i3000s/ AC Current Probe Instruction Sheet Introduction The i3000s 24 Flex, i3000s 36 Flex, and AC Current Probes (the Probe) are used with oscilloscopes, digital multimeters, recorders or data loggers.
More informationMAX. AC 600V HOLD V M H.V. LIVE CIRCUIT DIGITAL INSULATION TESTER DO NOT OPERATE IF LIT POWER DATA HOLD TEST ON / OFF 250V 500V 1000V OFF CAT.
INSULATION TESTER EARTH MAX. AC 600V LINE AC -+ HOLD V k M LIVE CIRCUIT DIGITAL INSULATION TESTER DO NOT OPERATE IF LIT M H.V. POWER DATA HOLD TEST ON / OFF 250V 500V 1000V ACV OFF 0 CAT.III 600V INSTRUCTION
More informationi400s Calibration Information Introduction
i400s AC Current Clamp Introduction XWWarning To avoid electric shock or injury, do not perform the performance tests or calibration procedures unless you are qualified to do so. The information provided
More informationMY /2-DIGIT DIGITAL MULTIMETER Users Manual
MY-65 4 1/2-DIGIT DIGITAL MULTIMETER Users Manual Read the Users Manual thoroughly before use. WARRANTY This instrument is warranted to be free from defects in material and workmanship for a period of
More informationUSER MANUAL. 200A AC Mini Clamp Meter. Model MA130. Please visit for user manual translations
USER MANUAL 200A AC Mini Clamp Meter Model MA130 Please visit www.extech.com for user manual translations Introduction Thank you for selecting the Extech Instruments 200A AC Mini Clamp Meter. The MA130
More informationINSTRUCTION MANUAL CM95/ CM100 TRUE RMS FLEXIBLE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT
CM95/ CM100 TRUE RMS FLEXIBLE CLAMP METER INSTRUCTION MANUAL 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT These instructions contain both information and warnings
More informationRS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to
RS-3 PRO RS-1007 PRO CAT IV Analog Clamp meter Series Users Manual For detailed specifications and ordering info go to www.testequipmentdepot.com RS-3 PRO RS-1007 PRO CAT IV Analog Clampmeter Series English
More informationINSTRUCTION MANUAL CM69 TRMS AC EARTH LEAKAGE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT
CM69 TRMS AC EARTH LEAKAGE CLAMP METER INSTRUCTION MANUAL 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT These instructions contain both information and warnings
More information323/324/325 Clamp Meter
323/324/325 Clamp Meter Users Manual PN 4045153 May 2012 2012 Fluke Corporation. All rights reserved. Printed in China. Specifications are subject to change without notice. All product names are trademarks
More informationPRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to
PRM-4 Phase Sequence and Motor Rotation Tester Users Manual For detailed specifications and ordering info go to www.testequipmentdepot.com PRM-4 Phase Sequence and Motor Rotation Tester English Users Manual
More informationInstruction Manual ICM A1 AC/DC Clamp Meter ICM A1
Instruction Manual ICM A1 AC/DC Clamp Meter EN ICM A1 Warning...................................... Safety sheet.............................................. Read First Safety Information - Use the instrument
More informationWPS600. Hydraulic Pressure Transducer. User s Guide. 600 bar 60 MPa 8700 psi
WPS600 Hydraulic Pressure Transducer User s Guide This accessory complies with the following standards: Electromagnetic Compatibility (EMC) Directive 2004/108/EC FCC Part 15 Pressure Equipment Directive
More informationInstruction Manual. 99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Model 308A Digital Insulation & Continuity Meter
Instruction Manual 99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com Model 308A Digital Insulation & Continuity Meter INDEX PAGE INSTRUMENT LAYOUT... 1 INTRODUCTION... 2 SAFETY
More informationTest Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL PSMR1
Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com INSTRUCTION MANUAL PSMR1 Introduction Descriptions All the information you need in one device. Verify
More informationMM300. INSTRUCTION MANUAL Manual-Ranging Digital Multimeter
INSTRUCTION MANUAL Manual-Ranging Digital Multimeter MM300 DATA HOLD AUDIBLE CONTINUITY BATTERY TEST DIODE TEST 10A 2MΩ ESPAÑOL pg. 13 FRANÇAIS pg. 25 MM300-1390109ART.indd 1 9/21/2015 2:48:00 PM GENERAL
More information362 Clamp Meter. Users Manual
362 Clamp Meter Users Manual PN 3622678 August 2010, Rev. 1, 4/13 2010, 2013 Fluke Corporation. All rights reserved. Printed in China. Specifications are subject to change without notice. All product names
More information302+/303 Clamp Meter. Users Manual
302+/303 Clamp Meter Users Manual PN 4045130 September 2011 2011 Fluke Corporation. All rights reserved. Printed in China. Specifications are subject to change without notice. All product names are trademarks
More informationUsers Manual. Accessories Motor and Phase Rotation Indicator ships with the following items: 3 test leads 3 test probes 3 alligator clips 9 V battery
MS5900 Users Manual Table of Contents Introduction Motor and Phase Rotation Indicator is a handheld, battery-operated instrument designed to detect the rotary field of three-phase systems and determine
More informationK100 K110 AEMC INSTRUMENTS ENGLISH. User Manual. n DC/AC MICROPROBE. Model K mv/ma OFF. DC/AC MicroProbe
n DC/AC MICROPROBE K100 K110 ON OL! 1 mv/ma OFF AEMC INSTRUMENTS DC/AC MicroProbe Model K100 ENGLISH User Manual Statement of Compliance Chauvin Arnoux, Inc. d.b.a. AEMC Instruments certifies that this
More information365 Detachable Jaw True-rms Clamp Meter
365 Detachable Jaw True-rms Clamp Meter Users Manual PN 3622684 August 2010 2010 Fluke Corporation. All rights reserved. Printed in China. Specifications are subject to change without notice. All product
More informationBT508/BT510/BT520/BT521 Battery Analyzer Safety Sheet
BT508/BT510/BT520/BT521 Battery Analyzer Safety Sheet Go to www.fluke.com to register your product, download manuals, and find more information. A Warning identifies conditions and procedures that are
More information362 Clamp Meter. Users Manual
362 Clamp Meter Users Manual PN 3622678 August 2010 2010 Fluke Corporation. All rights reserved. Printed in China. Specifications are subject to change without notice. All product names are trademarks
More informationOPERATING INSTRUCTIONS
CM OPERATING INSTRUCTIONS 9 Function, Auto Range Digital Multi-Meter DM6450 INTERTEK Read this owner s manual thoroughly before use and save. C LISTED US I. DISPLAY FUNCTIONS & SYMBOLS 9 6 10 11 14 8 7
More information1587 FC/1587/1577. Insulation Multimeter. Safety Information. Warnings
1587 FC/1587/1577 Insulation Multimeter Safety Information Go to www.fluke.com to register your Product and find more information. A Warning identifies conditions and procedures that are dangerous to the
More informationUSE AND CARE GUIDE DUALCHECK CIRCUIT TESTER
Item # 1002 153 664 Model #CE-VD7504GFI USE AND CARE GUIDE DUALCHECK CIRCUIT TESTER Questions, problems, missing parts? Before returning to the store, call Commercial Electric Customer Service 8 a.m. 7
More informationOperator s Manual TC-253A. Temperature Converter
Operator s Manual TC-253A Temperature Converter TM Temperature Converter WARRANTY The TC-253A Temperature Converter is warranted against any defects of material or workmanship within a period of one (1)
More informationBK BK A BK MA BK MA BK J93 MN93-BK MN193-BK MR193-BK SL261-BK SR193-BK
n COMPATIBLE CURRENT PROBES & SENSORS FOR POWER QUALITY METERS 193-24-BK 193-36-BK A196-24-BK MA193-10-BK MA193-14-BK J93 MN93-BK MN193-BK MR193-BK SL261-BK SR193-BK E N G L I S H User Manual Copyright
More informationBK BK J93 MA BK MA BK MN93-BK MN193-BK MR193-BK SL261-BK SR193-BK
n 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com COMPATIBLE CURRENT PROBES & SENSORS FOR POWER QUALITY METERS 193-24-BK 193-36-BK
More informationINSTRUCTION MANUAL IDM97II DIGITAL MULTIMETER EN FR IT DE
INSTRUCTION MANUAL IDM97II DIGITAL MULTIMETER EN FR IT DE ISO-TECH IDM97II DIGITAL MULTIMETER INSTRUCTION MANUAL 1 2 WARNING THESE SERVICING INSTRUCTIONS ARE FOR USE BY QUALIFIED PERSONNEL ONLY. TO AVOID
More informationINSTRUCTION MANUAL IDM91E DIGITAL MULTIMETER EN FR IT DE JP
INSTRUCTION MANUAL IDM91E DIGITAL MULTIMETER EN FR IT DE JP ISO - TECH IDM 91E DIGITAL MULTIMETER INSTRUCTION MANUAL 1 2 WARNING THESE SERVICING INSTRUCTIONS ARE FOR USE BY QUALIFIED PERSONNEL ONLY. TO
More informationINSTRUCTION MANUAL DT173 DT175 DIGITAL THERMOMETERS ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING
DIGITAL THERMOMETERS INSTRUCTION MANUAL ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING Thank you for buying one of our products. For safety and a full understanding of its benefits please read this manual
More information373 Clamp Meter. Users Manual
373 Clamp Meter Users Manual PN 3612805 July 2010 2010 Fluke Corporation. All rights reserved. Printed in Taiwan. Specifications are subject to change without notice. All product names are trademarks of
More informationINSTRUCTION MANUAL MARTINDALE CM52 CLAMP METER. ELECTRIC Trusted by professionals. Other products from Martindale:
Other products from Martindale: 18th Edition Testers All-in-one s Calibration Equipment Continuity Testers Electrician s Kits Full Calibration & Repair Service Fuse Finders Digital Clamp Meters Digital
More information51 & 52 Series II. Users Manual. Thermometer. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.
51 & 52 Series II Thermometer Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com Users Manual English September 1999 Rev.2, 11/10 1999-2010 Fluke Corporation,
More information& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL
72-6850 & 72-6852 HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL Table of Contents Introduction 2 Specification 2 Safety 4 EMC 5 Installation 6 Connections 6 Operation 7 Maintenance and Repair 8 www.tenma.com
More informationPD-20 HIGH VOLTAGE PROBE INSTRUCTION MANUAL
PD-20 HIGH VOLTAGE PROBE INSTRUCTION MANUAL Index 1. Safety precaution... 2. Specifications... 3. Operation... 4. Warning... 5. Cleaning... 6. Rated environmental conditions... 7. Observe the international
More informationOPERATING INSTRUCTION
11/05 Form #273 OPERATING INSTRUCTION MODEL 4105 Disital Earth Resistance Tester 2150 joshua's Path, Suite 302, Hauppauge, NY 11788 Phone : 1-800-645-5398 or 1-639-231-7050 Fax : 1-639-434-3128 E-mail
More informationUser's Manual. High Voltage Megohmmeter. Analog Insulation Tester plus AC Voltage and Continuity Tests. Model
User's Manual High Voltage Megohmmeter Analog Insulation Tester plus AC Voltage and Continuity Tests Model 380353 Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects
More informationICA 39T INSTRUCTION MANUAL ICA39T AC/DC CURRENT TRANSDUCER
ICA 39T INSTRUCTION MANUAL ICA39T AC/DC CURRENT TRANSDUCER EN INTRODUCTION 1-1 Unpacking and Inspection Upon removing your new Clamp Meter from its packing, you should have the following items: 1. Current
More informationWPS bar, 60 MPa, 8700 psi Hydraulic Pressure Transducer. User s Guide
WPS600 600 bar, 60 MPa, 8700 psi Hydraulic Pressure Transducer User s Guide WPX600 2 DO187-5 1. Safety terms and symbols User s Guide Please review the following safety precautions to avoid injury and
More informationCalibration Manual. Detachable Jaw True-rms Clamp Meter
365 Detachable Jaw True-rms Clamp Meter Calibration Manual December 2010 2010 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks
More informationCalibrator Capabilities Function Range Resolution Measure V dc 28 V 1 mv Measure ma dc Source ma dc
707 Loop Calibrator Instruction Sheet Introduction The Fluke 707 Loop Calibrator (hereafter, the Calibrator) is a compact sourcing and measuring tool. The Calibrator tests current loops of 0-20 ma or 4-20
More informationWPS500X. 500 psi / 34.5 bar Automotive Pressure Transducer. User s Guide
WPS500X 500 psi / 34.5 bar Automotive Pressure Transducer User s Guide This accessory complies with the following standards: Electromagnetic Compatibility (EMC) Directive 2004/108/EC FCC Part 15 Pressure
More informationTrue RMS Autoranging Multimeter
Owner's Manual True RMS Autoranging Multimeter Model No. 73754 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation Maintenance
More informationUSER MANUAL. Insulation Tester + DMM. Model MG320
USER MANUAL Insulation Tester + DMM Model MG320 Table of Contents 1. INTRODUCTION 3 2. SAFETY 3 3. METER DESCRIPTION 5 4. CONTROL BUTTONS 6 5. SYMBOLS AND ANNUNCIATORS 6 6. OPERATING INSTRUCTIONS 7 6.1
More informationGo to to register your product and find more information.
ESA609 Electrical Safety Analyzer Safety Sheet Go to www.flukebiomedical.com to register your product and find more information. Safety Information A Warning identifies hazardous conditions and actions
More informationAutoranging Industrial Multimeter
Owner's Manual Autoranging Industrial Multimeter Model No. 82005 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation
More informationAutoranging Multimeter
Owner's Manual Autoranging Multimeter Model No. 82334 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation Maintenance
More informationUsers Manual. MegOhmMeter
1520 MegOhmMeter Users Manual September 2000 Rev.2, 2/03 2000-2003 Fluke Corporation. All rights reserved. Printed in USA All product names are trademarks of their respective companies. Table of Contents
More informationWPS500X 500 psi /34.5 bar Automotive Pressure Transducer. User s Guide
WPS500X 500 psi /34.5 bar Automotive Pressure Transducer User s Guide Pico Technology 1. Safety terms and symbols User s Guide Please review the following safety precautions to avoid injury and prevent
More informationDigital Multimeter User's Manual
Digital Multimeter User's Manual MS8239A MS8239A DIGITAL MULTIMETER Auto Power Off V HOLD 600 600 20 10A A m 10A 20m 2 m V MAX 10A/ 500V COM 600V CAT III IEC61010-1 12V 9V BATT. k 2M 600V MAX MAX ma/250v
More informationoperating manual DL7 101 DIGITAL THERMOMETER
operating manual DL7 101 DIGITAL THERMOMETER Safety Information This instrument is a portable 3½ digit., compact-sized digital thermometer designed to use external K-type thermocouple as temperature sensor.
More informationUsers Manual. Phase Rotation Indicator
9040 Phase Rotation Indicator Users Manual PN 2438546 April 2005, Rev.2, 5/11 2005-2011 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are
More informationINSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL TASCO, INC.
INSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL INS120P TASCO, INC. THIS TESTER IS DESIGNED FOR USE ONLY BY QUALIFIED ELECTRICIANS. IMPORTANT SAFETY WARNINGS mwarning Read and understand this material
More informationUser Guide. Model Insulation Tester / Megohmmeter
User Guide Model 380260 Insulation Tester / Megohmmeter Introduction Congratulations on your purchase of Extech s Insulation Tester/Megohmmeter. The Model 380260 provides three test ranges plus continuity
More informationInstruction Manual VT4 VOLTAGE TESTER. Check out what else you can get from Martindale:
Check out what else you can get from Martindale: 17th Edition Testers Accessories Calibration Equipment Continuity Testers Electricians Kits Environmental Products Full Calibration & Repair Service Fuse
More informationVol-Con XL (61-086) Voltage/Continuity Tester and Vol-Test (61-085) Voltage Tester Instruction Manual WARNING
Vol-Con XL (61-086) Voltage/Continuity Tester and Vol-Test (61-085) Voltage Tester Instruction Manual WARNING #61-085 #61-086 Read First: Safety Information This tester complies with UL3111-1, Cat III-600
More informationT2 Tester. Calibration Information. Introduction. Safety Information
T2 Calibration Information Introduction This calibration information sheet provides the following information for the T2 (hereafter referred to as "the tester"): Safety information Parts and service information
More informationMARTINDALE INSTRUCTIONS ELITE FUSE FINDER KIT ELECTRIC. Trusted by professionals. 4.4 Storage Conditions
4.4 Storage Conditions The FD650/R and FD500/T or FD600/T should be kept in warm dry conditions away from direct sources of heat or sunlight, with the battery removed and in such a manner as to preserve
More information1000FLT. Users Manual. Fluorescent Light Tester
1000FLT Fluorescent Light Tester Users Manual July 2014 2014 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks of their respective
More informationMODEL No: TA SAFETY INSTRUCTIONS 2. FEATURES. fig.1. Original Language Version
Instructions for: digital automotive analyser 14 function WITH IC MODEL No: TA303 Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these
More informationFor technical questions and replacement parts, please call
Digital CLAMP MULTIMETER 42396 95652 OPERATING INSTRUCTIONS Due to continuing improvements, actual product may differ slightly from the product described herein. 3491 Mission Oaks Blvd., Camarillo, CA
More informationOPERATING INSTRUCTION
11/05 Form #271 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 OPERATING INSTRUCTION Visit us at www.testequipmentdepot.com MODEL 3132 ANALOG INSULATION-CONTINUITY TESTER
More informationRental Industry Safety Tester Safe Check 5s
Rental Industry Safety Tester Safe Check 5s Feb 2006 2006 Clare Instruments Inc. Issue 2.0 Firmware Version : 1.2a Limited Warranty & Limitation of Liability Clare Instruments Inc, guarantees this product
More informationOPERATING INSTRUCTION
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com 8/05 Form #270 OPERATING INSTRUCTION MODEL 3005 DIGITAL INSULATION-CONTINUITY TESTER
More information1662/1663/1664 FC. Electrical Installation Tester. Safety Information. Warnings
1662/1663/1664 FC Electrical Installation Tester Safety Information Go to www.fluke.com to register your Product and find more information. A Warning identifies conditions and procedures that are dangerous
More informationDT33B/C/D OPERATOR S MANUAL LIMITED WARRANTY AND LIMITATION OF LIABILITY
BACK LIGHT D I G I TA L M U LT I M E T E R DT33B OPERATOR LIMITED WARRANTY AND LIMITATION OF LIABILITY This product will be free from defects in material and workmanship for one year from the date of purchase.
More informationINSTRUCTION MANUAL ANALOGUE INSULATION TESTER KEW 3131M KYORITSU ELECTRICAL INSTRUMENTS WORKS,LTD., TOKYO JAPAN
INSTRUCTION MANUAL ANALOGUE INSULATION TESTER KEW 3131M KYORITSU ELECTRICAL INSTRUMENTS WORKS,LTD., TOKYO JAPAN Contents 1. Safety Precautions... 1 2. Features... 3 3. Specifications... 4 4. Instrument
More informationSafety design conforming to the following provisions
Safety design conforming to the following provisions of IEC61010. Overvoltage category III 300V, pollution degree 2, Overvoltage category II 600V, pollution degree 2, Data hold switch for easy reading
More informationTX900. Microwave Leakage Detector. 99 Washington Street Melrose, MA Phone Toll Free
TX900 Microwave Leakage Detector 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Users Manual TX900 Microwave Leakage Detector
More informationDeclaration of Conformity
We Declaration of Conformity GOOD WILL INSTRUMENT CO., LTD. No. 7-1, Jhongsing Rd, Tucheng City, Taipei County 236, Taiwan GOOD WILL INSTRUMENT (SUZHOU) CO., LTD. No.69 Lushan Road, Suzhou New District
More informationINSTRUCTION MANUAL IDM93N DIGITAL MULTIMETER EN FR IT DE
INSTRUCTION MANUAL IDM93N DIGITAL MULTIMETER EN FR IT DE ISO-TECH IDM93N DIGITAL MULTIMETER INSTRUCTION MANUAL 1 2 WARNING THE SERVICING INSTRUCTIONS DESCRIBED WITHIN THIS MANUAL ARE FOR USE BY QUALIFIED
More informationUser Guide. Model Insulation Tester / Megohmmeter. Introduction
User Guide Model 380363 Insulation Tester / Megohmmeter Introduction Congratulations on your purchase of Extech s Insulation Tester/Megohmmeter. The Model 380363 provides three test ranges plus continuity
More informationKMP Insulation-Continuity Tester. Users Manual
KMP 7036 Insulation-Continuity Tester Users Manual KMP7036 Insulation-Continuity Tester Users Manual English September 2011, Rev.1 2011 Amprobe Test Tools. All rights reserved. Printed in China Limited
More informationDawson DDM190D. Digital Multimeter User s Manual
Dawson DDM190D Digital Multimeter User s Manual TABLE OF CONTENTS LIMITED WARRANTY AND LIMITATION OF LIABILITY... 3 Out of the Box... 3 Accessories... 4 Safety Information... 7 Certification... 7 INTRODUCTION...
More informationMOdel No: MM19.V3 WARNING CAUTION 1. SAFETY INSTRUCTIONS
Instructions for: Digital Multimeter - 6 Function MOdel No: MM19.V3 Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions
More informationDIGITAL RCD(ELCB) TESTER
INSTRUCTION MANUAL DIGITAL RCD(ELCB) TESTER KEW 5410 R KYORITSU ELECTRICAL INSTRUMENTS WORKS, LTD. Contents 1. Safety Warnings.... 1 2. Procedure of removing Cover. 3 2-1 Method of removing the Cover.
More informationFlex current clamps A 1179 A 1257 A 1395 User Manual Version 1.6; Code No
Flex current clamps A 1179 A 1257 A 1395 User Manual Version 1.6; Code No. 20 751 167 Distributor: Producer: METREL d.d. Ljubljanska 77 SI-1354 Horjul Tel.: +386 1 75 58 200 Fax: +386 1 75 49 226 E-mail:
More informationInstruction Manual PC104/PC105 3-PHASE SOCKET TESTER. Check out what else you can get from Martindale:
Check out what else you can get from Martindale: 17th Edition Testers Accessories Calibration Equipment Continuity Testers Electricians Kits Environmental Products Full Calibration & Repair Service Fuse
More informationIN1001/IN1003 ANALOGUE INSULATION & CONTINUITY TESTERS INSTRUCTION MANUAL IN1001/IN1003 ANALOGUE INSULATION & CONTINUITY TESTERS INSTRUCTION MANUAL
Martindale Electric Company LTD Metrohm House Penfold Trading Estate Imperial Way Watford Herts WD24 4YY T: 01923 441717 F: 01923 446900 Email: sales@martindale-electric.co.uk web: www.martindale-electric.co.uk
More informationOPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2
OPERATING AND MAINTENANCE MANUAL Product: Type: Primary Current Injection Test Set 750ADM mk2 750ADM-H mk2 DESIGNED AND MANUFACTURED BY: T & R Test Equipment Limited 15-16 Woodbridge Meadows, Guildford,
More informationSafety design conforming to the following provisions
Safety design conforming to the following provisions of IEC61010. Overvoltage category III 300V AC, pollution degree 2 Overvoltage category II 600V AC/DC, pollution degree 2 Protected throughout by double
More informationUser Guide. Model Insulation Tester / Megohmmeter
User Guide Model 380260 Insulation Tester / Megohmmeter Introduction Congratulations on your purchase of Extech s Insulation Tester/Megohmmeter. The Model 380260 provides three test ranges plus continuity
More informationTIC 300 PRO. Users Manual Mode d emploi Bedienungshandbuch Manual d uso Manual de uso. Non Contact AC Voltage Detector. High Energy Tic Tracer
TIC 300 PRO High Energy Tic Tracer Non Contact AC Voltage Detector Users Manual Mode d emploi Bedienungshandbuch Manual d uso Manual de uso TIC 300 PRO High Energy Tic Tracer Non Contact AC Voltage Detector
More information4-20mA DC PROCESS CLAMP METER
An ISO 9001:2008 Company The KM 071 Milliamp Process Clamp Meter is a Hand-held battery operated clamp meter that measures 4-20 ma DC without breaking the electrical circuit. Unlike conventional clamp
More informationMini Multimeter with Non-Contact Voltage Detector (NCV)
Owner s Manual Mini Multimeter with Non-Contact Voltage Detector (NCV) Model No. 82314 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product.
More informationINSTRUCTIONS FOR USE
ROGOWSKI CURRENT TRANSDUCERS INSTRUCTIONS FOR USE RCTi and RCTi-3ph POWER ELECTRONIC MEASUREMENTS Ltd. Gloucester House, Wellington Street, Long Eaton, Nottingham, NG10 4HT, U.K. Tel: +44 115 946 9657
More informationTable of Contents. Title Page UT501/UT502 OPERATING MANUAL. Introduction. Unpacking the Meter. Safety Information. International Electrical Symbols
Table of Contents Title Page Introduction Unpacking the Meter Safety Information International Electrical Symbols The Meter Structure Key Functions Rotary Switch Measurement Operation A. Measuring Voltages
More informationTable of Contents Title Page No.
Table of Contents Title Page No. INTRODUCTION 1 SAFETY PRECAUTIONS / WARNINGS 2 CONTROLS AND INDICATORS 4 PREPARATION AND CAUTION BEFORE USE 5 TESTING PROCEDURES 6 A. AC/DC VOLTAGE MEASUREMENT 6 B. RESISTANCE
More informationDigital/Analog Megohmmeter Model 1026 USER MANUAL
Digital/Analog Megohmmeter Model 1026 USER MANUAL Limited Warranty The Megohmmeter Model 1026, is warranted to the owner for a period of 2 years from the date of original purchase against defects in manufacture.
More information4-WIRE EARTH RESISTANCE TESTER C1 ES P1 S. Max. AC 200V MICROPROCESSOR CONTROLLED TEST. Switch ON, TEST, SCROLL RESULTS 20Ω 200Ω 2000Ω OFF
2734 ER 4-WIRE EARTH RESISTANCE TESTER E C1 ES P1 S P2 H C2 Max. AC 200V Rc Rp MICROPROCESSOR CONTROLLED Noise CATⅣ 200V PRESS TO: Switch ON, TEST, SCROLL RESULTS TEST 20Ω 200Ω 2000Ω OFF EARTH VOLTAGE
More informationPRM-2 PHASE SEQUENCE TESTER PRM-3 PHASE SEQUENCE & MOTOR ROTATION TESTER User s Manual
PRM-2 PHASE SEQUENCE TESTER PRM-3 PHASE SEQUENCE & MOTOR ROTATION TESTER User s Manual 99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com CONTENTS PRM-2 & PRM-3 1. Warranty...3
More information