Technical Specifications

Size: px
Start display at page:

Download "Technical Specifications"

Transcription

1 APPENDIXA Environmental and for the Switch, page A-1 Environmental and for the Power Supply and Fan Modules, page A-5 Environmental and for the Switch Table A-1 Environmental Ranges for the Switch Environmental Ranges Operating Environment and Altitude 1, 2 Normal Operating Ambient Air Temperature and Altitudes 23 to 122 F ( 5º to 50ºC), up to 1,000 feet (300 m) 23 to 113 F ( 5º to 45ºC), up to 6,000 feet (1800 m) 23 to 104 F ( 5º to 40ºC), up to 10,000 feet (3000 m) Short-Term 3 Exceptional Operating Ambient Air Temperature and Altitudes 23 to 140 F ( 5º to 60ºC), up to 1,000 feet (300 m) 23 to 131 F ( 5º to 55ºC), up to 6,000 feet (1800 m) 23 to 122 F ( 5º to 50ºC), up to 10,000 feet (3000 m) 23 to 113 F ( 5º to 45ºC), at sea level with single fan failure Normal Operating Internal Sensor Temperature 4º to 158 F ( 20º to 70ºC) Acoustic Noise 4 LpA: 43 db typical, 46 db maximum LwA: 5.4 B typical, 5.6 B maximum Relative humidity 5 to 95% (noncondensing) 5. Storage temperature 40 to 158 F ( 40 to 70 C). Storage altitude Up to 15,000 ft (4570 m). 1. GLC-T SFP can only be used from 23 to 122 F ( 5º to 50ºC) up to 1,000 feet (300 m) environment for normal operating and short-term conditions. 2. The switch supports 5ºC operation provided that it powers up at ambient temperature equal to or greater than 0ºC. SFP-10G-LRM SFP+ module can only be used from 32 to 122 F (0º to 50ºC). 3. Not to exceed more than 96 consecutive hours, 360 total hours, or 15 occurrences in a 1-year period. A-1

2 Environmental and for the Switch 4. Acoustic noise is measured per ISO 7779 and declared per ISO This can be limited by specification of optical modules. Table A-2 Physical Dimensions AC Power Requirements Power consumption with 1 AC power Power consumption with 2 AC power supply modules DC Power Requirements Power consumption with 1 DC power Power consumption with 2 DC power supply modules ME-3800X-24FS-M lb (6.58 kg) (no FRU ) 1.72 x x in. (4.37 x x cm) 100 to 240 VAC ± 10% (autoranging), 50 to 60 Hz. Total: 779 BTUs per hour (maximum). Maximum: 228 W (worst-case SFPs, SFP+ LRM, 100% Typical: 155 W (12 SFPs with 1000BASE-SX, 2 SFP+ with SR, 100% Minimum: 123 W (no cables or SFP modules ). Power rating: 120 V (0.254 KVA), 230 V (0.248 KVA). Total: 796 BTUs per hour (maximum). Maximum: 233 W (worst-case SFPs, SFP+ LRM, 100% Typical: 163 W (12 SFPs with 1000BASE-SX, 2 SFP+ with SR, 100% Minimum: 132 W (no cables or SFP modules ). Power rating: 120 V (0.259 KVA), 230 V (0.254 KVA). 18 to 32 VDC and 36 to 72 VDC. Total: 840 BTUs per hour (maximum). Maximum: 246 W (18 VDC input, worst-case SFPs, SFP+ LRM, 100% Typical: 156 W (48 VDC, 12 SFPs with 1000BASE-SX, 2 SFP+ with SR, 100% Minimum: 124 W (48 VDC, no cables or SFP modules ). Total: 813 BTUs per hour (maximum). Maximum: 238 W (18 VDC input, worst-case SFPs, SFP+ LRM, 100% Typical: 161 W (48 VDC, 12 SFPs with 1000BASE-SX, 2 SFP+ with SR, 100% Minimum: 129 W (48 VDC, no cables or SFP modules ). Note If you install one AC and one DC power supply module in a switch, the power specifications are similar to two DC power supply modules. A-2

3 Environmental and for the Switch Table A-3 ME-3600X-24FS-M Physical Dimensions AC Power Requirements Power consumption with 1 AC power Power consumption with 2 AC power supply modules DC Power Requirements Power consumption with 1 DC power Power consumption with 2 DC power supply modules lb (6.58 kg) (no FRU ) 1.72 x x in. (4.37 x x cm) 100 to 240 VAC ± 10% (autoranging), 50 to 60 Hz. Total: 762 BTUs per hour (maximum). Maximum: 223 W (worst-case SFPs, SFP+ LRM, 100% Typical: 155 W (12 SFPs with 1000BASE-SX, 2 SFP+ with SR, 100% Minimum: 123 W (no cables or SFP modules ). Power rating: 120 V (0.248 KVA), 230 V (0.243 KVA). Total: 778 BTUs per hour (maximum). Maximum: 228 W (worst-case SFPs, SFP+ LRM, 100% Typical: 163 W (12 SFPs with 1000BASE-SX, 2 SFP+ with SR, 100% Minimum: 132 W (no cables or SFP modules ). Power rating: 120 V (0.254 KVA), 230 V (0.243 KVA). 18 to 32 VDC and 36 to 72 VDC. Total: 823 BTUs per hour (maximum). Maximum: 241 W (18 VDC input, worst-case SFPs, SFP+ LRM, 100% Typical: 156 W (48 VDC, 12 SFPs with 1000BASE-SX, 2 SFP+ with SR, 100% Minimum: 124 W (48 VDC, no cables or SFP modules ). Total: 796 BTUs per hour (maximum). Maximum: 233 W (18 VDC input, worst-case SFPs, SFP+ LRM, 100% Typical: 161 W (48 VDC, 12 SFPs with 1000BASE-SX, 2 SFP+ with SR, 100% Minimum: 129 W (48 VDC, no cables or SFP modules ). Note If you install one AC and one DC power supply module in a switch, the power specifications are similar to two DC power supply modules. A-3

4 Environmental and for the Switch Table A-4 Physical Dimensions AC Power Requirements Power consumption with 1 AC power Power consumption with 2 AC power supply modules DC Power Requirements Power consumption with 1 DC power Power consumption with 2 DC power supply modules ME-3600X-24TS-M lb (6.42 kg) (no FRU ) 1.72 x x in. (4.37 x x cm) 100 to 240 VAC ± 10% (autoranging), 50 to 60 Hz. Total: 656 BTUs per hour (maximum). Maximum: 192 W (worst-case SFPs, SFP+ LRM, 100% Typical: 150 W (12 SFPs with 1000Base-SX, 2 SFP+ with SR, 100% Minimum: 117 W (no cables or SFP modules ). Power rating: 120 V (0.214 KVA), 230 V (0.209 KVA). Total: 677 BTUs per hour (maximum). Maximum: 198 W (worst-case SFPs, SFP+ LRM, 100% Typical: 158 W (12 SFPs with 1000BASE-SX, 2 SFP+ with SR, 100% Minimum: 126 W (no cables or SFP modules ). Power rating: 120 V (0.220 KVA), 230 V (0.215 KVA). 18 to 32 VDC and 36 to 72 VDC. Total: 711 BTUs per hour (maximum). Maximum: 208 W (18 VDC input, worst-case SFPs, SFP+ LRM, 100% Typical: 151 W (48 VDC, 12 SFPs with 1000BASE-SX, 2 SFP+ with SR, 100% Minimum: 117 W (48 VDC, no cables or SFP modules ). Total: 697 BTUs per hour (maximum). Maximum: 204 W, 18 VDC input (maximum fan speed, all ports linked). Typical: 157 W (48 VDC, SFP modules, 12 ports linked). Minimum: 124 W (48 VDC, no SFP modules ). Note If you install one AC and one DC power supply module in a switch, the power specifications are similar to two DC power supply modules. A-4

5 Environmental and for the Power Supply and Fan Modules Environmental and for the Power Supply and Fan Modules Table A-5 Environmental and Physical Specifications for the AC and DC Input Power Supply and Fan Modules Environmental Ranges Operating temperature 40 to 122 F ( 40 to 50 C) Storage temperature 49 to 185 F ( 45 to 85 C) Relative humidity 5 to 95% (noncondensing) Altitude Up to 10,000 ft (3049 m) Physical Specifications AC: 2.9 lb (1.32 kg) DC: 3.1 lb (1.41 kg) Fan: 1.65 lb (0.75 kg) 1.64 x 8.55 x 5.94 in. (4.16 x x cm) Table A-6 for the AC Power Supply Module Power Specifications Maximum output power range and frequency Input current Maximum output ratings Total input BTU 390 W 100 to 240 VAC ± 10% (autoranging), 50 to 60 Hz 5 to 2.5 A Note For AC input, a 5A fuse is recommended A 1705 BTUs per hour Table A-7 for the DC Power Supply Module Power Specifications Maximum output power range Input current Maximum output ratings Total input BTU 390 W 18 to 32 VDC and 36 to 72 VDC 30 A maximum at minimum input 18VDC 15 A maximum at maximum input voltage 72VDC Note For DC input, a 25A fuse is recommended A 1840 BTUs per hour A-5

6 Environmental and for the Power Supply and Fan Modules A-6

Technical Specifications

Technical Specifications APPENDIXA Switch Specifications Table A-1 Environmental and Physical Specifications Environmental Ranges Operating 1 temperature 23 to 113 F ( 5 to 45 C) Operating 1 temperature with FIPS kit 23 to 104

More information

IN-LINE CENTRIFUGAL DUCT FANS VT Series

IN-LINE CENTRIFUGAL DUCT FANS VT Series IN-LINE CENTRIFUGAL DUCT FANS VT Series DESCRIPTION The VT series of circular in-line duct centrifugal fans consists of model variations within nominal model sizes of,,,,, and mm respectively. The VT range

More information

Ultra-quiet circular duct fans TD-SILENT ECOWATT Series

Ultra-quiet circular duct fans TD-SILENT ECOWATT Series TD-SILENT ECOWATT - MODELS 5 to TD-SILENT ECOWATT - MODELS AND At 5% of full speed fan power consumption is reduced by 7% Low profile Mixed-flow fans with sound-absorbent insulation, extremely quiet, fan

More information

Getting Started With Your System

Getting Started With Your System Dell PowerConnect RPS720, MPS600, MPS1000, and MPS 1U Shelf Getting Started With Your System Regulatory Model PowerConnect RPS720, MPS600, and MPS1000 Notes, Cautions, and Warnings NOTE: A NOTE indicates

More information

AC axial fan. Limited partnership Headquarters Mulfingen County court Stuttgart HRA

AC axial fan. Limited partnership Headquarters Mulfingen County court Stuttgart HRA S4D45-AP3- ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-74673 Mulfingen Phone +49 7938 8- Fax +49 7938 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court

More information

AC axial fan. blades with special design (K series) with guard grille for full nozzle

AC axial fan. blades with special design (K series) with guard grille for full nozzle SE6-EC-5 ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8- Fax +9 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart

More information

Multifunctional 400ºC/2h and 300ºC/2h roof fans

Multifunctional 400ºC/2h and 300ºC/2h roof fans HTMF Multifunctional 400ºC/2h and 300ºC/2h roof fans Multifunctional 400ºC/2h ceiling fans to work inside fire danger zones, designed for smoke extraction in industrial or similar buildings. 0370-CPR-0544

More information

400ºC/2h and 300ºC/2h roof-mounted helical extractor fans with vertical air outlet

400ºC/2h and 300ºC/2h roof-mounted helical extractor fans with vertical air outlet THT/ROOF ROOF-MOUNTED SMOKE EXTRACTOR FANS THT/ROOF 400ºC/2h and 300ºC/2h roof-mounted helical extractor fans with vertical air outlet Roof-mounted helical extractor fans with vertical air outlet, for

More information

Regenerative DC Common Bus Supply

Regenerative DC Common Bus Supply Regenerative DC Common Bus Supply The Regenerative DC Common Bus Supply supplies both motoring and regenerative current to the DC bus of one or more AC drives without the need of rectifier front end in

More information

AC centrifugal fan. forward curved, dual inlet with housing (flange)

AC centrifugal fan. forward curved, dual inlet with housing (flange) DE-AM7- ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8- Fax +9 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart

More information

AC axial fan. sickled blades (S series) with guard grille for full nozzle

AC axial fan. sickled blades (S series) with guard grille for full nozzle SD-BH8- ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8- Fax +9 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart

More information

AC axial fan. sickled blades (S series), single inlet Wall ring with guard grille

AC axial fan. sickled blades (S series), single inlet Wall ring with guard grille WE5-CO5-66 ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8- Fax +9 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart

More information

CONTRA ROTATING CASED AXIAL FANS TCBBx2 / TCBTx2 Series

CONTRA ROTATING CASED AXIAL FANS TCBBx2 / TCBTx2 Series Range of cylindrical cased axial fans fitted with aluminium impellers and manufactured from high grade rolled galvanised steel and protected against corrosion by cataforesis primer and black polyester

More information

AC axial fan. sickled blades (S series) Wall ring with guard grille

AC axial fan. sickled blades (S series) Wall ring with guard grille W4E3-DN2-39 ebm-papst Mulfingen GmbH & Co. KG Bachmühle 2 D-74673 Mulfingen Phone +49 7938 81- Fax +49 7938 81-11 info1@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County

More information

AC centrifugal fan. backward curved

AC centrifugal fan. backward curved RE8-CB8- ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8- Fax +9 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart

More information

56 mm sq. (2.20 inch sq.)

56 mm sq. (2.20 inch sq.) 56 mm sq. (2.2 inch sq.) 1.8 /step RoHS Bipolar winding, Lead wire type Unipolar winding, Lead wire type p. 68 Customizing Hollow Shaft modification Decelerator Encoder Varies depending on the model number

More information

GE.VO.360/325.SS+0_all

GE.VO.360/325.SS+0_all . Generating Set Diesel +0_all Standard Equipment and features Canopy - Soundproofing Engine Soundproof canopy IP 32 monoblock Engine heater 230 V Polyester class1 soundproofing High coolant temperature

More information

Axial fans 400ºC/2h and 300ºC/2h With soundproofed box. Extraction units with axial fans to work inside fire danger zones.

Axial fans 400ºC/2h and 300ºC/2h With soundproofed box. Extraction units with axial fans to work inside fire danger zones. CJTHT Axial fans 400ºC/2h and 300ºC/2h With soundproofed box Extraction units with axial fans to work inside fire danger zones. Fan: Sheet steel long casing fan. Galvanised sheet steel structure with thermal

More information

AC axial fan. sickled blades (S series) with full square nozzle

AC axial fan. sickled blades (S series) with full square nozzle WD5-GA-9 ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8- Fax +9 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart

More information

High performance Vector Control. Ratings. System configuration

High performance Vector Control. Ratings. System configuration System configuration High performance Vector Control Low harmonic or regenerative drive IP54 full range Compact design and robustness Built-in filter (according to C3 class) Built-in fuses (from 200 kw)

More information

PowerWAVE EL. Technical Specification. (Single phase 500 VA 30 kva. Three phase kva)

PowerWAVE EL. Technical Specification. (Single phase 500 VA 30 kva. Three phase kva) PowerWAVE EL (Single phase 500 VA 30 kva Three phase 10-160 kva) Technical Specification 1 PowerWAVE EL 100XA Model EL1005XA EL1012XA EL1030XA Power rating VA / W 500 / 400 1250 / 1000 3000 / 2400 /tolerance

More information

CC3060 TYPE 12 COMPACT CABINET COOLER AIR-TO-WATER FLUSH-MOUNT MODEL

CC3060 TYPE 12 COMPACT CABINET COOLER AIR-TO-WATER FLUSH-MOUNT MODEL CC3060 TYPE 12 CC3060 13 lbs 9,300 0.3 1 x 6 30 x 8-3/4 x 4 Efficiency: 68.8 Watts / C T based on average internal cabinet temperature. 2. CC3060 Rated cooling: 2,725 Watts mounted to an uninsulated 72

More information

General_technical_data Series

General_technical_data Series Indicator Lens Actuator Cable 2-poles with plug-in connection 2.8 x 0.8 mm Flat plug-in housing rectangular, AMP No. 626 057-0 Receptacle housing AMP No. 626 0-0 Receptacle socket AMP No. 160 655-2 Wire

More information

Field IT Actuators & Positioners Rotary Actuators - Rated Torque 100 Nm (80 ft-lbs) PME 120-AI/AN. Rotary Actuators Rated Torque 100 NM (80 ft-lbs)

Field IT Actuators & Positioners Rotary Actuators - Rated Torque 100 Nm (80 ft-lbs) PME 120-AI/AN. Rotary Actuators Rated Torque 100 NM (80 ft-lbs) Data Sheet Field IT Actuators & Positioners Rotary Actuators - Rated Torque 100 Nm (80 ft-lbs) PME 120-AI/AN Electric actuator for continuous duty modulating or pulse input control. Stall proof without

More information

EFFEKTA Power Supplies

EFFEKTA Power Supplies EFFEKTA GENERAL INFORMATION UPS topology ON LINE - Double Conversion Classification VFI-SS-111 in accordance with IEC 62040-3 Nominal output power (Cos Ø 0,9) - kva 10 15 20 30 40 Nominal output power

More information

1LG0 Low-voltage Motors

1LG0 Low-voltage Motors Low-voltage motors up to 315kW Catalog D81.5.1 1LG Low-voltage Motors Answers for industry. 1 Table of Contents Overview 3 Motor standards 5 Mechanical design 6 Electrical design 1 Converter fed application

More information

TECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out)

TECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out) TECHNICAL DATA SHEET B8033FXS 10 15 20 kva 3Ph(In) 3Ph(Out) GENERAL INFORMATION UPS Type ON LINE Double Conversion Nominal output power (Cosϕ 0.9) kva 10 15 20 Nominal output power (Cosϕ 1.0) kw 9 13.5

More information

Cisco Nexus 7700 Switches Environment

Cisco Nexus 7700 Switches Environment Data Sheet Cisco Nexus 7700 Switches Environment Data Sheet Product Overview The Cisco Nexus 7700 platform is the latest extension to the modular Cisco Nexus 7000 Series Switches. Capable of 83 terabits

More information

IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series

IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series Range of low profile in-line mixed flow duct fans manufactured in tough reinforced plastic (from to models) or with metal casing steel finished in a tough epoxy-polyester paint coating (from to models).

More information

TECHNICAL DATA SHEET B8031 FXS kva 3Ph(In) 1Ph(Out)

TECHNICAL DATA SHEET B8031 FXS kva 3Ph(In) 1Ph(Out) TECHNICAL DATA SHEET B8031 FXS 10 15 20 kva 3Ph(In) 1Ph(Out) GENERAL INFORMATION UPS Type ON LINE Double Conversion Nominal output power (Cos 0.9) kva 10 15 20 Nominal output power (Cos 1.0) kw 9 13.5

More information

CUSTOMER: MODEL NO: 4020III (CeraDyna Fan) PART NO: FD1240-A0241D0AL DATE: CUSTOMER APPROVAL. Taiwan. Approved QC Checked Checked Prepared

CUSTOMER: MODEL NO: 4020III (CeraDyna Fan) PART NO: FD1240-A0241D0AL DATE: CUSTOMER APPROVAL. Taiwan. Approved QC Checked Checked Prepared CUSTOMER: MODEL NO: 4020III (CeraDyna Fan) PART NO: FD1240-A0241D0AL DATE: 2013.08.28 CUSTOMER APPROVAL Taiwan ACT-RX TECHNOLOGY CORPORATION TEL: 886-2-82421111 2F, No.192, Lian Cheng Road, Zhonghe Dist.,

More information

THT/HATCH THT/HATCH. Order code THT/HATCH 40 2T 1 N 1 G

THT/HATCH THT/HATCH. Order code THT/HATCH 40 2T 1 N 1 G THT/HATCH High-powered ventilators with motorised opening and equipped with a roof fan, for smoke extraction in the event of a fire, 400ºC/2h High-powered ventilators with roof fan and motorised opening.

More information

MH1WC4W-08-1-B Chilled/Hot Water 1-Way Cassette Fan Coil

MH1WC4W-08-1-B Chilled/Hot Water 1-Way Cassette Fan Coil MH1WC4W-08-1-B Chilled/Hot Water 1-Way Cassette Fan Coil 4-Pipe Heat / Cool Fan Coil 24,000 BTUH Rev. 1.11 HVAC Guide Specifications Chilled and Hot Water Cassette Fan Coil 4-Pipe Nominal Size: 24,000

More information

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalouge

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalouge CENTRIFLOW 3D plug fan WITH AC MOTOR >> Technical catalouge air comfort Centriflow 3D 2 GMEB CentriFlow 3D - Technical Catalouge Contents GENERAL Description and survey chart Application... 3 General Survey

More information

Heat recovery ventilators with rotating exchanger, automatic control and EC motor, designed for vertical ducts and installation in technical room

Heat recovery ventilators with rotating exchanger, automatic control and EC motor, designed for vertical ducts and installation in technical room RIRS V EKO Heat recovery ventilators with rotating exchanger, automatic control and EC motor, designed for vertical ducts and installation in technical room Common characteristics: Efficient low-noise

More information

Product discontinuation. Notices. Discontinuation Notice of Safety Relay and Socket. G7S series, P7S series. Wire connection

Product discontinuation. Notices. Discontinuation Notice of Safety Relay and Socket. G7S series, P7S series. Wire connection PRODUCT NEWS Product Discontinuation Notices February 1, 2012 Safety Relays No. 2012037E Discontinuation Notice of Safety Relay and Socket., P7S series Product Discontinuation Safety Relay Socket P7S series

More information

Analog Low Volume Air Samplers

Analog Low Volume Air Samplers F&J SPECIALTY PRODUCTS, INC. The Nucleus of Quality Air Monitoring Programs Analog Low Volume Air Samplers 100 120 VAC LV-1 LV-14M LV-1D FJ-28BMHT FJ28B SRS-14MHT LV-22 SRS-14MHT Rev: 14 June 2018 Tel:

More information

L1 = Solder terminal 2.8 x 0.5 mm Ø Behind panel

L1 = Solder terminal 2.8 x 0.5 mm Ø Behind panel Raised design Emergency-stop switch, foolproof EN IEC 60947-5-5, IP 65 Equipment consisting of (schematic overview) L1 35.6 6 max. 59.5 41 18x24 Actuator Product can differ from the current configuration.

More information

Multifunctional roof fans for large flows. Multifunctional roof fans, highly robust construction, for large flows

Multifunctional roof fans for large flows. Multifunctional roof fans, highly robust construction, for large flows HTMH Multifunctional roof fans for large flows Multifunctional roof fans, highly robust construction, for large flows Fan: Painted galvanised sheet steel base plate Turnable impellers cast aluminium. Protection

More information

POWER kva

POWER kva TECHNICAL DATA SHEET B9000 FXS 60-80-100-125-160kVA +44 (0)20 8868 3732 GENERAL INFORMATION UPS Type ON LINE Double Conversion Nominal output power (Cos φ 0,8) kva 60 80 100 125 160 Nominal output power

More information

Power Supply Specifications

Power Supply Specifications 3000 W Supply Specifications, page 1 3000 W Power Supply AC Power Cords, page 3 Chassis and and Heat Values, page 9 3000 W Supply Specifications The following table lists specifications for the 3000 W

More information

36CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 36,000 BTUH

36CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 36,000 BTUH 36CWA4-HW 4-Pipe Chilled & Hot Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 36,000 BTUH Rev. 1.2 HVAC Guide Specifications Chilled & Hot Multi-Position Fan Coil 4-Pipe Nominal Size: 36,000 BTUH Multiaqua

More information

24CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V)

24CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V) 24CWA4-HW 4-Pipe Chilled & Hot Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 24,000 BTUH Rev. 1.2 HVAC Guide Specifications Chilled & Hot Multi-Position Fan Coil 4-Pipe Nominal Size: 24,000 BTUH Multiaqua

More information

Dimensions WxHxD [mm] Weight [kg]

Dimensions WxHxD [mm] Weight [kg] SPECIFICATIONS The SOLSTART electronic soft starter incorporates two sets of thyristors (Two phase control) to start a threephase squirrel cage induction motor and an internal bypass. By supplying a slowly

More information

The New Filter Valve Technology

The New Filter Valve Technology The New Filter Valve Technology HIGH FLOW, QUICK RESPONSE.. Connections Ports available in NPT, and BSPP G thread to international standards Response Minimized space above the diaphragm guarantees fast

More information

AC axial fan. straight blades (A series) with full round nozzle

AC axial fan. straight blades (A series) with full round nozzle WD-CA- ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8- Fax +9 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart

More information

48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH

48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH 48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled or Hot Water with Optional Electric Heat Multi-Position

More information

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC Manufacturer s declaration in accordance with 8- Frame Model catalogue reference 93PS-XX(20)-YY- 93PS-XX(40)-YY- Number of power modules (UPM) 1 1 or 2 Number of internal batteries 0 to 2 x 32 blocks 0

More information

AC centrifugal fan. backward curved

AC centrifugal fan. backward curved RE-AB6- ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8- Fax +9 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart

More information

E-Series and EF-Series Systems

E-Series and EF-Series Systems E-Series and EF-Series Systems Site Preparation Guide NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone: +1 (888) 463-8277

More information

Specification of Battery Charger

Specification of Battery Charger 1 S O N E I L 6033 Shawson Dr., Unit 29, Mississauga, Ontario, Canada L5T 1H8 Ph.: (905) 565-0360 Fax: (905) 565-0352 http://www.soneil.com Revision No.: R01 Specification of Battery Charger MODEL: 6010SR

More information

Maximize your ROI. Conext CL-60 String Inverter. The ideal solution for decentralized power plants and commercial rooftops

Maximize your ROI. Conext CL-60 String Inverter. The ideal solution for decentralized power plants and commercial rooftops Maximize your ROI Conext CL-60 String Inverter The ideal solution for decentralized power plants and commercial rooftops solar.schneider-electric.com 2016 Schneider Electric. All rights reserved. All trademarks

More information

K Service Source. PowerCD

K Service Source. PowerCD K Service Source PowerCD K Service Source Specifications PowerCD Specifications Characteristics - 1 Characteristics Access Time Average:.55 sec. (typical) Maximum (first to last block): 1 sec. (typical)

More information

POWER kva

POWER kva +44 (0)20 8868 3732 TECHNICAL DATA SHEET B9600 400-800kVA GENERAL INFORMATION UPS Type ON LINE - Doppia Conversione Nominal output power (Cos φ0,8) kva 400 500 600 800 Nominal output power (Cos φ1,0) kw

More information

F&J SPECIALTY PRODUCTS, INC.

F&J SPECIALTY PRODUCTS, INC. F&J SPECIALTY PRODUCTS, INC. The Nucleus of Quality Air Monitoring Programs PORTABLE ANALOG HIGH VOLUME AIR SAMPLERS BY F&J SPECIALTY PRODUCTS, INC. 100 120 VAC HV-1 HV-1S HV-1RT HV-1BC HV1SBC Comet Style

More information

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES GAMATRONIC, A SolarEdge Division 47505 Seabridge Drive, Fremont, CA, 94538 USA Tel: 1-800-277-5496 SalesNA.Gama@solaredge.com www.gamatronicna.com

More information

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES GAMATRONIC, A SolarEdge Division 47505 Seabridge Drive, Fremont, CA, 94538 USA Tel: 1-800-277-5496 SalesNA.Gama@solaredge.com www.gamatronicna.com

More information

Phoenix DX Sensorless AC Vector Drive. 3 HP to 3500 HP

Phoenix DX Sensorless AC Vector Drive. 3 HP to 3500 HP Phoenix DX Sensorless AC Vector Drive 3 HP to 3500 HP Standard Features: * PRECISE CONTROL OF MOTOR SPEED AND TORQUE * BI-DIRECTIONAL FLYCATCHER (CATCH SPINNING MOTOR) * EASY TO USE, SIMPLE SETUP * POWER

More information

PRO POWER 2 0 A L I T H I U M B AT T E RY C H A R G E R M O D E L : P P - L B C V E R S I O N : V 1. 0

PRO POWER 2 0 A L I T H I U M B AT T E RY C H A R G E R M O D E L : P P - L B C V E R S I O N : V 1. 0 PRO POWER 2 0 A L I T H I U M B AT T E RY C H AR G E R M O D E L : P P - L B C - 1 2 2 0 V E R S I O N : V 1. 0 Contents 1. Revised History... 1 2. Warning... 1 3. Notes... 1 4. Product Number System...

More information

A flexible, reliable and affordable drive for 1/4 through 2 HP DC applications

A flexible, reliable and affordable drive for 1/4 through 2 HP DC applications A flexible, reliable and affordable drive for 1/4 through 2 HP DC applications DC2 drives combine application flexibility, compact size and reliability into an affordable adjustable speed package that

More information

MHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil. Heat / Cool Fan Coil 24,000 BTUH. Rev. 1.3

MHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil. Heat / Cool Fan Coil 24,000 BTUH. Rev. 1.3 MHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil Heat / Cool Fan Coil 24,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Hi-Wall Fan Coil 2-Pipe Nominal Size: 24,000 BTUH Multiaqua Model

More information

Submersible Vacuum Fault Interrupters

Submersible Vacuum Fault Interrupters Submersible Vacuum Fault Interrupters UG Distribution Medium Voltage Vacuum Fault Interrupters Functional Specification Guide PS024002EN Functional Specification for 2.4kV to 17.5kV UG Distribution Medium

More information

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS G115QX G115X ELECTRICAL FREQUENCY VOLTAGE PRIME STAND BY 50Hz 3ph 400/230v 107.7kVA / 86.2kW 118.5kVA / 94.8kW 60Hz 3Ph 380/220v 102.0kVA / 81.6kW 111.9kVA

More information

Datasheet. Pitch Motor PMSM SP260B8

Datasheet. Pitch Motor PMSM SP260B8 Pitch Motor PMSM SP260B8 Permanent Magnet Compact and light weight High peak torque Excellent efficiency Maintenance free, No fan 5 year warranty Document no.: 4121260012a 1 Application The Pitch motor

More information

Datasheet. Pitch Motor PMSM SP190C8

Datasheet. Pitch Motor PMSM SP190C8 Pitch Motor PMSM SP190C8 Permanent Magnet Compact and light weight High peak torque Excellent efficiency Maintenance free, No fan 5 year warranty Document no.: 4121260007a 1 Application The Pitch motor

More information

PL900 ILLUMINATOR. Fiber-Lite. Operation Manual. Setup. Fiber Optic Connection A PRODUCT OF DOLAN-JENNER INDUSTRIES. Voltage Selection:

PL900 ILLUMINATOR. Fiber-Lite. Operation Manual. Setup. Fiber Optic Connection A PRODUCT OF DOLAN-JENNER INDUSTRIES. Voltage Selection: PL900 ILLUMINATOR A PRODUCT OF DOLAN-JENNER INDUSTRIES Setup Voltage Selection: Operation Manual Read and review the instructions on the label covering the power entry module and the instructions in this

More information

Datasheet. Pitch Motor PMSM SP190F8

Datasheet. Pitch Motor PMSM SP190F8 Pitch Motor PMSM SP190F8 Permanent Magnet Compact and light weight High peak torque Excellent efficiency Maintenance free, No fan 5 year warranty Document no.: 4121260009c 1 Application The Pitch motor

More information

Cast resin transformers

Cast resin transformers Product catalogue Cast resin transformers according to IEC/EN 60076, VDE 0532, DIN 42523 Power range up to 8 MVA Voltage range up to 36 kv Conductor material: copper or aluminum Protection types: IP 00

More information

18091-PS. Preliminary General Specification PSM (AC) PES REV: PAGE. 1 of 8

18091-PS. Preliminary General Specification PSM (AC) PES REV: PAGE. 1 of 8 18091-PS Preliminary General Specification PSM204-120(AC) PES REV: PAGE. 1 of 8 MODEL: PSM204-120(AC) PRELIMIARY GENERAL SPECIFICATION 1. AC Input Specification : 1.1 AC input voltage rating: 100-240VAC

More information

Sola/Hevi-Duty S3K Series Mini-Tower UPS

Sola/Hevi-Duty S3K Series Mini-Tower UPS Sola/Hevi-Duty S3K Series Mini-Tower UPS GUIDE SPECIFICATIONS 700VA to 1600VA 120V models Single - Phase Uninterruptible Power Supply Systems 1.1 SUMMARY 1.0 GENERAL This specification defines the electrical

More information

BOX BLB Centrifugal Box Fan

BOX BLB Centrifugal Box Fan Centrifugal Box Fan Select models available for next day delivery Product Overview 3 sizes from 260mm to 400mm Air volume flow rates up to 0.751m³/s Static pressures up to 733 Pa Suitable for operating

More information

Safety & Shut-off Blocks

Safety & Shut-off Blocks Safety & Shut-off Blocks Description HYDAC safety and shut-off blocks are designed to protect, shut-off, and discharge hydraulic accumulators or user units. The compact design simplifies the hydraulic

More information

SCXI Power Supply/Float Charger Installation Guide

SCXI Power Supply/Float Charger Installation Guide SCXI -1383 Power Supply/Float Charger Installation Guide Conventions This guide describes how to install and use the SCXI-1383 power supply/float charger. The SCXI-1383 is a 13.8 VDC, 4 A power supply/float

More information

Specification of Battery Charger

Specification of Battery Charger Revision No.: 02 Specification of Battery Charger MODEL: 2460SR-1 24V / 30A IP-54 LEAD ACID BATTERY CHARGER Page 1 of 11 Contents 1. General--------------------------------------------------------------------------3

More information

magellan commercial UPS solutions Magellan Power Modular - Flexible UPS

magellan commercial UPS solutions Magellan Power Modular - Flexible UPS magellan commercial UPS solutions Magellan Power Modular - Flexible UPS Commercial UPS Solutions 2 MPM3320-60kVA MPM3320-100kVA MPM3320-200kVA MPM3340-400kVA MPM3340-520kVA 2015 W www.magellan-power.com.au

More information

Plate mounted axial flow fans HXBR / HXTR Series

Plate mounted axial flow fans HXBR / HXTR Series Plate mounted axial flow fans manufactured from high grade galvanised steel and provided with a Sickle blade impeller, low sound level, protected against corrosion by cataforesis primer and a polyester

More information

Dell Networking W-7200 Series mobility controllers

Dell Networking W-7200 Series mobility controllers Dell Networking W-7200 Series mobility controllers Next-generation networking platforms optimized for best-in-class mobile application delivery over Wi-Fi The Dell Networking W-7200 Series mobility controllers

More information

A36D CONTROLLED FERRORESONANT RECTIFIER / POWER SUPPLY BATTERY CHARGER / POWER SUPPLY. Standard Features

A36D CONTROLLED FERRORESONANT RECTIFIER / POWER SUPPLY BATTERY CHARGER / POWER SUPPLY. Standard Features A36D BATTERY CHARGER / POWER SUPPLY ISO 9001 CERTIFIED Standard Features Model Shown: A36D--48V-ABD1-24L CONTROLLED FERRORESONANT RECTIFIER / POWER SUPPLY The La Marche Model A36D Controlled Ferroresonant

More information

Robust wall-mounted axial or long-cased fans, PL version supplied with plastic impeller and AL version supplied with aluminium impeller

Robust wall-mounted axial or long-cased fans, PL version supplied with plastic impeller and AL version supplied with aluminium impeller HCH HCT HCH HCT Order code Robust wall-mounted axial or long-cased fans Robust wall-mounted axial or long-cased fans, PL version supplied with plastic impeller and AL version supplied with aluminium impeller

More information

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalogue

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalogue CENTRIFLOW 3D plug fan WITH AC MOTOR >> Technical catalogue air comfort Centriflow 3D 2 GMEB CentriFlow 3D - Technical Catalogue Contents GENERAL Description and survey chart Application... 3 General Survey

More information

Power Supplies PSS Series

Power Supplies PSS Series 8 January 2009 PSS Supplies Product Description Eaton s of power supplies is designed to work in a variety of applications, including the power supply to the IT. line of power control products. They also

More information

SmartOnline 120V 2.2kVA 1.8kW Double-Conversion UPS, 2U, Extended Run, Network Card Slot, LCD, USB, DB9

SmartOnline 120V 2.2kVA 1.8kW Double-Conversion UPS, 2U, Extended Run, Network Card Slot, LCD, USB, DB9 SmartOnline 120V 2.2kVA 1.8kW Double-Conversion UPS, 2U, Extended Run, Network Card Slot, LCD, USB, DB9 MODEL NUMBER: AL-84111 Specifications OUTPUT Output Volt Amp Capacity (VA) 2200 Output kva Capacity

More information

ORION PLUS three-phase kVA

ORION PLUS three-phase kVA ORION PLUS three-phase 30-1250kVA Orion Plus stabilizers are available for different ranges of input voltage fluctuation. In the ±15%/ ±20% and ±25%/ ±30% types, the change of input range is obtained through

More information

Warner Instruments 1125 Dixwell Avenue, Hamden, CT (800) / (203) (203) fax

Warner Instruments 1125 Dixwell Avenue, Hamden, CT (800) / (203) (203) fax VC-8 Manual, Rev. 050817.1 1 Perfusion Valve Controller Model VC-8 1125 Dixwell Avenue, Hamden, CT 06514 (800) 599-4203 / (203) 776-0664 (203) 776-1278 - fax VC-8 Manual, Rev. 050817.1 2 Table of Contents

More information

ILLUMINATOR LV. Emergency Lighting Inverter System 175VA through 750VA. Illuminator Series LV Single Phase

ILLUMINATOR LV. Emergency Lighting Inverter System 175VA through 750VA. Illuminator Series LV Single Phase ILLUMINATOR LV Emergency Lighting Inverter System 175VA through 750VA Illuminator Series LV Single Phase ILLUMINATOR SERIES LV The Illuminator Series LV is a 175VA-750VA fast transfer Emergency Lighting

More information

Product Data Sheet 4118 N/ The engineer's choice

Product Data Sheet 4118 N/ The engineer's choice The engineer's choice 4118 N/12-190 INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 4 3.1 Electrical Operating Data... 4 3.2 Operating Data - Electrical

More information

D Series: UPS UPTO - 300KVA - Three / Three Phase

D Series: UPS UPTO - 300KVA - Three / Three Phase D Series: UPS UPTO - 300KVA - Three / Three Phase All in one D Series UPS High Power UPS Systems, Now in India Properties : Standard Properties 1GBT rectifier inverter technology Input power factor correction

More information

PowerValue 11/31 T kva

PowerValue 11/31 T kva Technical Datasheet PowerValue 11/31 T 10-20 kva Classification IEC/EN 62040-3 VFI-SS-111 Working mode on-line double conversion Power rating 10-20 kva Paralleling up to 4 units (up to 80 kva) Output power

More information

Internet For latest information, PDF catalogs and operation manuals

Internet  For latest information, PDF catalogs and operation manuals EcoRich Features Achieves a % or greater energy saving (in the pressure retained mode, comparison with Daikin products) Drastic energy savings are realized by reducing the motor rotation speed in pressure

More information

accessory guide Indoor AP Accessories Compatible Products Description Picture Kit Contents

accessory guide Indoor AP Accessories Compatible Products Description Picture Kit Contents Indoor AP Compatible Products Description Picture Kit Contents 902-0100-0000 ZoneFlex 7982 ZoneFlex R700 Multipurpose mounting bracket for 7982 supports mounting to hard wall, ceiling, electrical outlet

More information

Power+ CLASSIC. 20/30 kva, 3x208 Vac

Power+ CLASSIC. 20/30 kva, 3x208 Vac Power+ CLASSIC 20/30 kva, 3x208 Vac with internal batteries Power+ CLASSIC 20/30 kva, 3x208 Vac Power+ is a family of modular, parallel, redundant UPS systems from Gamatronic one of the leading companies

More information

Quick guide. Plug-in fans GPPM with FC101_106 August 2014

Quick guide. Plug-in fans GPPM with FC101_106 August 2014 Quick guide Plug-in fans GPPM with FC101_106 August 2014 Fläkt Woods permanent magnet motors and speed controllers for plug fans GPPM 1. General Fläkt Woods offers a wide range of permanent magnet motors

More information

CUSTOMER: MODEL NO: 4020II (CeraDyna Fan) NO: FD2440-C0151D2AL. DATE : September 3, 2007 CUSTOMER APPROVAL

CUSTOMER: MODEL NO: 4020II (CeraDyna Fan) NO: FD2440-C0151D2AL. DATE : September 3, 2007 CUSTOMER APPROVAL CUSTOMER: MODEL NO: 4020II (CeraDyna Fan) PART NO: FD2440-C0151D2AL DATE : September 3, 2007 CUSTOMER APPROVAL Taiwan TEL: 886-2-82421111 2F, No. 192, Lien Chen Road, Chung Ho City, FAX: 886-2-82452200

More information

SteelCentral Product Family Specifications

SteelCentral Product Family Specifications Specification Sheet SteelCentral Product Family Specifications Riverbed SteelCentral NetProfiler Solutions Product Specifications SteelCentral NetProfiler 8, 9, 10 SCNP-04270 Series Model SCNP-02270 Series

More information

Compact Design BB101 & 93

Compact Design BB101 & 93 Acoustic Shield Natural Ventilation Acoustic Roof Vents Compact Design BB101 & 93 Standard / Twin Flow / Mixed Mode natural ventilation roof vents can be finished in any colour to compliment the architectural

More information

MaxPak Plus Analog DC V S Drive

MaxPak Plus Analog DC V S Drive Three-Phase 3-600 HP non-regenerative and 5-150 HP regenerative drives Designed to accommodate a wide range of industrial requirements, the DC V S Drive has been widely applied worldwide. Selected ratings

More information

burners with or without fan. It conforms to EN C). APPROVAL EU type test approval as per EU Gas Appliance Directive.

burners with or without fan. It conforms to EN C). APPROVAL EU type test approval as per EU Gas Appliance Directive. LAST UPDATE 29/08/12 INSTALLATION INSTRUCTIONS v. 3 UNIT SPECIFICATIONS Main Gas Valve, Pilot Gas Valve Ionisation, Ignition and Flame Monitoring with Common Electrode or Remote Sensor Integrated Cyclic

More information

1.2. Reduced Voltage Motor Starters. Contents Description Type S611, Soft Starters... Type S801+, Soft Starters. Type S801+, Soft Starters

1.2. Reduced Voltage Motor Starters. Contents Description Type S611, Soft Starters... Type S801+, Soft Starters. Type S801+, Soft Starters Reduced Voltage Motor Starters.2 Type S80+, Soft Starters Contents Type S6, Soft Starters..................... Type S80+, Soft Starters Operation.............................. Features...............................

More information

0.6A, 1.5A, 2.25A, 3A/Phase

0.6A, 1.5A, 2.25A, 3A/Phase 2-Phase Bipolar motor Driver Compact 2-Phase stepper motor driver Features Easy installation with compact size(w85 H21 D64mm) Bipolar constant current drive type Current decay mode decreases vibration

More information

AT30 SERIES BATTERY CHARGER

AT30 SERIES BATTERY CHARGER STANDARD FEATURES 5 YEAR WARRANTY 5 Year Product Warranty Universal main control board operates in any AT Series charger Alarm assembly with local LEDs and summary relay contact for AC Failure, DC Failure,

More information