Robust wall-mounted axial or long-cased fans, PL version supplied with plastic impeller and AL version supplied with aluminium impeller

Size: px
Start display at page:

Download "Robust wall-mounted axial or long-cased fans, PL version supplied with plastic impeller and AL version supplied with aluminium impeller"

Transcription

1 HCH HCT HCH HCT Order code Robust wall-mounted axial or long-cased fans Robust wall-mounted axial or long-cased fans, PL version supplied with plastic impeller and AL version supplied with aluminium impeller Fan: Airflow direction from motor to impeller PL version impellers in polyamide 6 reinforced with fibreglass and AL version in cast aluminium. HCT-40-2T and HCT-45-2T models only in AL version HCH: Support ring in sheet steel HCT: Sheet steel long casing with external terminal board Motor: IE2 efficiency motors for capacities equal to or over 0.75kW and below 7.5kW, except single-phase, 2 speed and 8 pole motors. IE3 efficiency motors for capacities equal to or over 7.5kW, except single-phase, 2 speed and 8 pole motors. Class F motors, with ball bearings and IP55 protection, except single-phase versions from size 45 to size 56, IP54 protection One-or two-speed depending on the model Single-phase 230V-50Hz and three-phase 230/400V-50Hz (up to 4kW) and 400/690V-50Hz (power over 4kW) Fan working temperature: -25ºC + 50ºC Finish: Anticorrosive finish in polyester resin polymerised at 190ºC, after alkaline degreasing with phosphate-free nanotechnology treatment. On request: IE2 and IE3 efficiency motors for any power. Airflow direction from impeller to motor. 100% reversible impellers. Special windings for different voltages. ATEX certification, Category 2 HCH 40 2T 1.5 PL PV HCH: Robust wall-mounted axial fans HCT: Robust long-cased axial fans Impeller diameter in cm. Number of motor poles 2=2900 r/min. 50 Hz 4=1400 r/min. 50 Hz 6=900 r/min. 50 Hz 8=750 r/min. 50 Hz 12=500 r/min. 50 Hz T=Three-phase Motor power M=Single-phase (HP) PL=Plastic PV=Distributor impeller AL=Aluminium impeller Technical characteristics Model Speed Maximum admissible current (A) Installed capacity Maximum airflow Sound pressure level Approx. weight (Kg) (r/min) 230V 400V 690V (kw) (m 3 /h) db(a) HCH HCT HCT 25-2T HCT 25-2M HCT 25-4T HCT 25-4M HCT 31-2T HCT 31-2M HCT 31-4T HCT 31-4M HCH HCT 35-2T HCT 35-2M HCH HCT 35-4T HCT 35-4M HCH HCT 40-2T HCH HCT 40-4T HCT 45-2T HCT 45-2T HCT 45-2/4T / / / / /73 33 HCH HCT 45-4T HCH HCT 45-4M HCH 45-6T HCH 45-6M

2 Technical characteristics Model Speed Maximum admissible current (A) Installed capacity Maximum airflow Sound pressure level Approx. weight (Kg) (r/min) 230V 400V 690V (kw) (m 3 /h) db(a) HCH HCT HCT 50-4T HCH HCT 56-4T HCH HCT 56-4M HCH HCT 56-4T HCH HCT 56-4/8T / / / / / HCH HCT 56-4T HCH HCT 56-4/8T / / / / / HCH HCT 56-4T HCH HCT 56-4/8T / / / / / HCH HCT 56-6T HCH HCT 56-6M HCH HCT 56-6T HCH HCT 56-6T HCH HCT 63-4T HCH HCT 63-4/8T / / / / / HCH HCT 63-4T HCH HCT 63-4/8T / / / / / HCH HCT 63-4T HCH HCT 63-4/8T / / / / / HCH HCT 63-4T HCH HCT 63-4/8T / / / / / HCH HCT 63-4T HCH HCT 63-4/8T / / / / / HCH HCT 63-6T HCH HCT 63-6M HCH HCT 63-6T HCH HCT 63-6T HCH HCT 63-6/12T / / / / / HCH HCT 71-4T HCH HCT 71-4/8T / / / / / HCH HCT 71-4T HCH HCT 71-4/8T / / / / / HCH HCT 71-4T HCH HCT 71-4/8T / / / / / HCH HCT 71-4T HCH HCT 71-4/8T / / / / / HCH HCT 71-6T HCH HCT 71-6M HCH HCT 71-6T HCH HCT 71-6/12T / / / / / HCH HCT 71-6T HCH HCT 71-6/12T / / / / / HCH HCT 80-4T HCH HCT 80-4/8T / / / / / HCH HCT 80-4T HCH HCT 80-4/8T / / / / / HCH HCT 80-4T HCH HCT 80-4/8T / / / / / HCH HCT 80-6T HCH HCT 80-6/12T / / / / / HCH HCT 80-6T HCH HCT 80-6/12T / / / / / HCH HCT 80-6T HCH HCT 80-6/12T / / / / / HCH HCT 80-6T HCH HCT 80-6/12T / / / / / HCH HCT 80-8T HCH HCT 80-8T HCH HCT 80-8T HCH HCT 90-4T HCH HCT 90-4/8T / / / / / HCH HCT 90-4T

3 Technical characteristics Model Speed Maximum admissible current (A) Installed capacity Maximum airflow Sound pressure level Approx. weight (Kg) (r/min) 230V 400V 690V (kw) (m 3 /h) db(a) HCH HCT HCH HCT 90-4/8T / / / / / HCH HCT 90-4T HCH HCT 90-4/8T / / / / / HCH HCT 90-4T-10 IE HCH HCT 90-4/8T / / / / / HCH HCT 90-6T HCH HCT 90-6/12T / / / / / HCH HCT 90-6T HCH HCT 90-6/12T / / / / / HCH HCT 90-6T HCH HCT 90-6/12T / / / / / HCH HCT 90-8T HCH HCT 90-8T HCH HCT 90-8T HCH HCT 90-8T HCH HCT 100-4T HCH HCT 100-4/8T / / / / / HCH HCT 100-4T-10 IE HCH HCT 100-4/8T / / / / / HCH HCT 100-4T-15 IE HCH HCT 100-4/8T / / / / / HCH HCT 100-4T-20 IE HCH HCT 100-4/8T / / / / / HCH HCT 100-6T HCH HCT 100-6/12T / / / / / HCH HCT 100-6T HCH HCT 100-6/12T / / / / / HCH HCT 100-6T HCH HCT 100-6/12T / / / / / HCH HCT 100-8T HCH HCT 100-8T HCH HCT 100-8T HCH HCT 100-8T Erp. BEP (best efficiency point) characteristics MC EC VSD SR Measurement category Efficiency category S Static T Total Variable-speed drive Specific relationship ηe[%] Efficiency N Degree of efficiency [kw] Electrical power [m 3 /h] Airflow [mmh 2 O] Static or total pressure (According to EC) [RPM] Speed Model MC EC VSD SR ηe [%] N [kw] [m3/h] [mmh 2 O] [RPM] 25-2T A S NO % M T T A S NO % M T M A S NO % T A S NO % M A S NO % T T-1.5 A S NO % T-0.33 A S NO % T-2 A S NO % T-3 A S NO % /4T-3 A S NO % T-0.5 A S NO % M-0.5 A S NO %

4 Erp. BEP (best efficiency point) characteristics Model MC EC VSD SR ηe [%] N [kw] [m3/h] [mmh 2 O] [RPM] 50-4T-0.75 B T NO % T-0.75 A S NO % M-0.75 A S NO % T-1 B T NO % /8T-1 B T NO % T-1.5 B T NO % /8T-1.5 B T NO % T-0.33 A S NO % T-1 C S NO % /8T-1 C S NO % T-1.5 C S NO % /8T-1.5 C S NO % T-2 C S NO % /8T-2 C S NO % T-3 B T NO % /8T-3 B T NO % T-4 B T NO % /8T-4 B T NO % T-0.5 C S NO % M-0.5 C S NO % T-0.75 C S NO % T-1.5 C S NO % /8T-1.5 C S NO % T-2 C S NO % /8T-2 C S NO % T-3 C S NO % /8T-3 C S NO % T-4 C S NO % /8T-4 C S NO % T-0.75 C S NO % M-0.75 C S NO % T-1 C S NO % /12T-1 C S NO % T-1.5 C S NO % /12T-1.5 C S NO % T-3 C S NO % /8T-3 C S NO % T-4 C S NO % /8T-4 C S NO % T-5.5 C S NO % /8T-5.5 C S NO % T-1 C S NO % /12T-1 C S NO % T-1.5 C S NO % /12T-1.5 C S NO % T-2 C S NO % /12T-2 C S NO % T-3 B T NO % /12T-3 B T NO % T-0.5 C S NO % T-0.75 C S NO % T-1 C S NO % T-4 C S NO % /8T-4 C S NO % T-5.5 C S NO % /8T-5.5 C S NO % T-7.5 C S NO % /8T-7.5 C S NO % T-10 IE3 C S NO % /8T-10 C S NO % T-2 C S NO % /12T-2 C S NO % T-3 C S NO % /12T-3 C S NO % T-4 B T NO % /12T-4 B T NO % T-1 C S NO % T-1.5 C S NO %

5 Erp. BEP (best efficiency point) characteristics Model MC EC VSD SR ηe [%] N [kw] [m3/h] [mmh 2 O] [RPM] 90-8T-2 C S NO % T-3 C S NO % T-7.5 C S NO % /8T-7.5 C S NO % T-10 IE3 C S NO % /8T-10 C S NO % T-15 IE3 C S NO % /8T-15 C S NO % T-20 IE3 C S NO % /8T-20 C S NO % T-3 C S NO % /12T-3 C S NO % T-4 C S NO % /12T-4 C S NO % T-5.5 C S NO % /12T-5.5 C S NO % T-1.5 C S NO % T-2 C S NO % Acoustic features The specified values are determined according to free field measurements of pressure and sound levels in db(a) at an equivalent distance of twice the fan s span plus the impeller s diameter, with a minimum of 1.5 m. Sound power Lw(A) spectrum in db(a) via frequency band in Hz. Model Model (2v) (2v) (2v) (2v) (2v) (2v) (2v) (2v) (2v) (2v) (2v) (2v) (2v) (2v) (2v) (2v) (2v) (2v) (2v) (2v) (2v) (2v) (2v) (2v) (2v) (2v) (2v) (2v) (2v) (2v) (2v) (2v) (2v) (2v) (2v) (2v) (2v)

6 Dimensions in mm HCH E Model ØA ØB ØC ØD F ØJ N HCH X 45º HCH X 45º HCH X 45º HCH X 45º HCH X 45º HCH X 45º HCH X 30º HCH X 30º HCH X 30º HCH X 30º HCH X 22º30 HCH X 22º30 HCH X 22º30 HCH X 22º30 HCH X 22º30 HCH X 22º30 HCH X 22º30 HCH X 22º30 HCH X 22º30 HCH X 22º30 HCH X 22º30 HCT Model ØA ØB ØD E E1 ØJ N HCT x90º HCT x90º HCT x45º HCT x45º HCT x45º HCT x30º HCT x30º HCT x30º HCT x22º30 HCT x22º30 HCT x22º30 HCT x22º30 HCT-100-4T x22º30 HCT-100-4T x22º30 32

7 Characteristic curves Q = Airflow in m 3 /h, m 3 /s and cfm. Pe= Static pressure in mmh 2 O, Pa and inwg. 2 Poles=3000 r/min 2 Poles=3000 r/min 4 Poles=1500 r/min 4 Poles=1500 r/min 4 Poles=1500 r/min 4 Poles=1500 r/min 33

8 Characteristic curves Q = Airflow in m 3 /h, m 3 /s and cfm. Pe= Static pressure in mmh 2 O, Pa and inwg. 4 Poles=1500 r/min 4 Poles=1500 r/min 4 Poles=1500 r/min 4 Poles=1500 r/min 6 Poles=1000 r/min 6 Poles=1000 r/min 34

9 Characteristic curves Q = Airflow in m 3 /h, m 3 /s and cfm. Pe= Static pressure in mmh 2 O, Pa and inwg. 6 Poles=1000 r/min 6 Poles=1000 r/min 6 Poles=1000 r/min 6 Poles=1000 r/min 8 Poles=750 r/min 8 Poles=750 r/min 35

10 Characteristic curves Q = Airflow in m 3 /h, m 3 /s and cfm. Pe= Static pressure in mmh 2 O, Pa and inwg. 4 Poles (2-speed motor)=2/4 Poles 8 Poles (2-speed motor)=4/8 Poles 8 Poles (2-speed motor) =4/8 Poles 8 Poles (2-speed motor)=4/8 Poles 8 Poles (2-speed motor)=4/8 Poles 8 Poles (2-speed motor)=4/8 Poles 36

11 Characteristic curves Q = Airflow in m 3 /h, m 3 /s and cfm. Pe= Static pressure in mmh 2 O, Pa and inwg. 8 Poles (2-speed motor) =4/8 Poles 12 Poles (2-speed motor)=6/12 Poles 12 Poles (2-speed motor)=6/12 Poles 12 Poles (2-speed motor)=6/12 Poles 12 Poles (2-speed motor)=6/12 Poles 12 Poles (2-speed motor)=6/12 Poles Accessories See accessories section. INT RM AR C2V VSD3/A-RFT CUADROS PL P PT/H R RI RT BTUB BAC PS VSD1/A-RFM S SI PV 37

Axial or tubular wall-mounted fans, PL version fitted with a plastic rotor and AL version with an aluminium rotor.

Axial or tubular wall-mounted fans, PL version fitted with a plastic rotor and AL version with an aluminium rotor. HCH HCH Extremely robust wall-mounted, axial or tubular fans Axial or tubular wall-mounted fans, PL version fitted with a plastic rotor and AL version with an aluminium rotor. Fan: Airflow direction from

More information

HCH-HCT/EW EFFICIENT WORK. Wall-mounted or long-cased axial fans fitted with high-efficiency IE3 asynchronous motor adjustable electronically.

HCH-HCT/EW EFFICIENT WORK. Wall-mounted or long-cased axial fans fitted with high-efficiency IE3 asynchronous motor adjustable electronically. HCH-HCT/EW AC HIGHLY EFFICIENT IE3-COMPLIANT THREE-PHASE MOTORS AC VARIABLE SPEED DRIVE VSD: Variable Speed Drive.. VSD1/A-RFM. VSD3/A-RFT Supply on request CONTROL Supply optional accesory SUPPLY VSD1/A-RFM:

More information

HCH/ATEX: Robust wall-mounted axial fans with ATEX certification HCT/ATEX: Robust long-cased axial fans with ATEX certification

HCH/ATEX: Robust wall-mounted axial fans with ATEX certification HCT/ATEX: Robust long-cased axial fans with ATEX certification HCH/ATEX HCT/ATEX HCH/ATEX: Robust wall-mounted axial fans with ATEX certification HCT/ATEX: Robust long-cased axial fans with ATEX certification Circular axial fans (HCH) or Long-cased fans (HCT) with

More information

Multifunctional roof fans for large flows. Multifunctional roof fans, highly robust construction, for large flows

Multifunctional roof fans for large flows. Multifunctional roof fans, highly robust construction, for large flows HTMH Multifunctional roof fans for large flows Multifunctional roof fans, highly robust construction, for large flows Fan: Painted galvanised sheet steel base plate Turnable impellers cast aluminium. Protection

More information

400ºC/2h centrifugal roof fans with horizontal or vertical air outlet CHT 200 4T BS. Installed capacity

400ºC/2h centrifugal roof fans with horizontal or vertical air outlet CHT 200 4T BS. Installed capacity 400ºC/2h centrifugal roof fans with horizontal or vertical air outlet : 400ºC/2h centrifugal roof fans with horizontal air outlet, hood in aluminium : 400ºC/2h centrifugal roof fans with vertical air outlet,

More information

Multifunctional 400ºC/2h and 300ºC/2h roof fans

Multifunctional 400ºC/2h and 300ºC/2h roof fans HTMF Multifunctional 400ºC/2h and 300ºC/2h roof fans Multifunctional 400ºC/2h ceiling fans to work inside fire danger zones, designed for smoke extraction in industrial or similar buildings. 0370-CPR-0544

More information

Dynamically-balanced impellers with extremely robust cores CMP T 5.5

Dynamically-balanced impellers with extremely robust cores CMP T 5.5 Medium pressure, single inlet centrifugal fans with sheet steel casing and impeller Fan: Sheet steel casing. Forward-curved impeller made of galvanised sheet steel. 38-2M model casing in cast aluminium.

More information

High-efficiency long-cased axial fans fitted industrial Brushless motor E.C. Fibreglass-reinforced plastic impeller.

High-efficiency long-cased axial fans fitted industrial Brushless motor E.C. Fibreglass-reinforced plastic impeller. HEPT/EW with High-efficiency long-cased axial fans fitted industrial Brushless motor E.C. BRUSHLESS MOTOR BRUSHLESS INDUSTRIAL E.C. Fibreglass-reinforced plastic impeller. Fan: Airflow direction from motor

More information

CAS 460 2T 7.5. Impeller size motor poles 2=3500 r/min. 60 Hz. Installed power

CAS 460 2T 7.5. Impeller size motor poles 2=3500 r/min. 60 Hz. Installed power CAS CAS: High pressure, single inlet centrifugal fans with sheet steel casing and impeller : High pressure, single inlet centrifugal fans with sheet steel casing and impeller, fitted with acoustic attenuators

More information

400ºC/2h and 300ºC/2h roof-mounted helical extractor fans with vertical air outlet

400ºC/2h and 300ºC/2h roof-mounted helical extractor fans with vertical air outlet THT/ROOF ROOF-MOUNTED SMOKE EXTRACTOR FANS THT/ROOF 400ºC/2h and 300ºC/2h roof-mounted helical extractor fans with vertical air outlet Roof-mounted helical extractor fans with vertical air outlet, for

More information

CJBD/ALF CJBX/ALS CJBX/ALF CJBD/ALS VENTILATION UNITS WITH ALUMINIUM PROFILES. According EU Regulation

CJBD/ALF CJBX/ALS CJBX/ALF CJBD/ALS VENTILATION UNITS WITH ALUMINIUM PROFILES. According EU Regulation CJBD/AL CJBD/ALS CJBD/ALF CJBX/AL CJBX/ALS CJBX/ALF VENTILATION UNITS WITH ALUMINIUM PROFILES According EU Regulation CJBD/AL CJBD/ALS CJBD/ALF CJBD/AL: Soundproofed ventilation units with profiles in

More information

THT/HATCH THT/HATCH. Order code THT/HATCH 40 2T 1 N 1 G

THT/HATCH THT/HATCH. Order code THT/HATCH 40 2T 1 N 1 G THT/HATCH High-powered ventilators with motorised opening and equipped with a roof fan, for smoke extraction in the event of a fire, 400ºC/2h High-powered ventilators with roof fan and motorised opening.

More information

CMR/EW EFFICIENT WORK

CMR/EW EFFICIENT WORK CMR/EW AC VARIABLE SPEED DRIVE VSD: Variable Speed Drive.. VSD1/A-RFM. VSD3/A-RFT Supply on request CONTROL Supply optional accesory SUPPLY VSD1/A-RFM: 220-240 V 50/60 Hz VSD3/A-RFT: 380-415 V 50/60 Hz

More information

Axial fans 400ºC/2h and 300ºC/2h With soundproofed box. Extraction units with axial fans to work inside fire danger zones.

Axial fans 400ºC/2h and 300ºC/2h With soundproofed box. Extraction units with axial fans to work inside fire danger zones. CJTHT Axial fans 400ºC/2h and 300ºC/2h With soundproofed box Extraction units with axial fans to work inside fire danger zones. Fan: Sheet steel long casing fan. Galvanised sheet steel structure with thermal

More information

CMP/EW EFFICIENT WORK

CMP/EW EFFICIENT WORK CMP/EW High-efficiency centrifugal single-inlet, medium-pressure fans with a direct motor and impeller with forward-facing blades fitted with IE3 asynchronous motor adjustable electronically. AC HIGHLY

More information

Centrifugal medium-pressure fans fitted with multi-blade

Centrifugal medium-pressure fans fitted with multi-blade CMP/ATEX CMP/ATEX impeller Centrifugal medium-pressure fans fitted with multi-blade with ATEX certification Centrifugal single-inlet, medium-pressure fans with casing and sheet steel impeller to work in

More information

HEAVY DUTY FANS FOR INDUSTRIAL APPLICATIONS

HEAVY DUTY FANS FOR INDUSTRIAL APPLICATIONS HEAVY DUTY FANS FOR INDUSTRIAL APPLICATIONS OUR COMMITMENT TO THE ENVIRONMENT Sodeca has begun a new stage of study and design of new trends in ventilation which will help to preserve the environment and

More information

CMP-L/EW B T D. Industrial Brushless Motors E.C. Motor power (CV) Three-phase VSD 400 V50/60 Hz. electrical power Maximum.

CMP-L/EW B T D. Industrial Brushless Motors E.C. Motor power (CV) Three-phase VSD 400 V50/60 Hz. electrical power Maximum. CMP-L/EW BRUSHLESS INDUSTRIAL BRUSHLESS MOTOR E.C. VARIABLE SPEED DRIVE VSD: Variable Speed Drive.. VSD1/B. VSD3/B Supply included with fan CONTROL Supply optional accesory SUPPLY VSD1/B: 220-240 V 50/60

More information

HIGH-POWERED VENTILATORS

HIGH-POWERED VENTILATORS HIGH-POWERED VENTILATORS WITH ROOF FANS 400ºC/2h The THT/HATCH series was designed using high-powered ventilator technology for smoke extraction in the event of a fire, and is equipped with THT series

More information

Fans for ATEX EXPLOSIVE ATMOSPHERES

Fans for ATEX EXPLOSIVE ATMOSPHERES Fans for ATEX EXPLOSIVE ATMOSPHERES An ATEX area is a mixture of air and inflammable gas, the vapour of an inflammable liquid, a fog of combustible liquid or combustible powder, which, if they catch fire,

More information

TSAT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJTSA: Ventilation units with a forward-curved impeller.

TSAT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJTSA: Ventilation units with a forward-curved impeller. TSA TSAT CJTSA TSA: Single inlet, belt-driven centrifugal fans with shaft outlet and forward-curved impeller. TSAT: Single inlet, belt-driven centrifugal fans fitted with electric motors, a set of pulleys

More information

UDT UDTX FILTRATION UNITS AND AIR TREATMENT MODULES

UDT UDTX FILTRATION UNITS AND AIR TREATMENT MODULES MF: Filtration Modules UDT ME: Modules with electrically heated coils MA: Modules with water coils UDTX UDT UDTX FILTRATION UNITS AND AIR TREATMENT MODULES According EU Regulation UDT UDT Soundproofed

More information

CRL. MADE OF SHEET STEEL TURBINE WITH REACTION BLADES LOW NOISE LEVEL IE3 > 0.75kw MOTORS ENERGY SAVING MOTORS CRL MEDIUM PRESSURE CENTRIFUGAL FANS

CRL. MADE OF SHEET STEEL TURBINE WITH REACTION BLADES LOW NOISE LEVEL IE3 > 0.75kw MOTORS ENERGY SAVING MOTORS CRL MEDIUM PRESSURE CENTRIFUGAL FANS CRL MADE OF SHEET STEEL TURBINE WITH REACTION BLADES LOW NOISE LEVEL IE3 > 0.75kw MOTORS ENERGY SAVING MOTORS CRL MEDIUM PRESSURE CENTRIFUGAL FANS CRL Medium pressure, single-stage aspiration fans with

More information

CSXRT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJSXR: Ventilation units with a backward-curved impeller

CSXRT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJSXR: Ventilation units with a backward-curved impeller CSXR CSXRT CJSXR CSXR: Belt-driven single inlet centrifugal fans with shaft outlet and backward-curved impeller CSXRT: Belt-driven single inlet centrifugal fans fitted with electric motors, a set of pulleys

More information

CJSX-SILENT 400º/2H BELT-DRIVEN EXTRACTION UNITS SOUNDPROOFED DOUBLE-WALL OF SOUNDPROOFING 40 MM THICK

CJSX-SILENT 400º/2H BELT-DRIVEN EXTRACTION UNITS SOUNDPROOFED DOUBLE-WALL OF SOUNDPROOFING 40 MM THICK CJSX-SILENT 400º/2H BELT-DRIVEN EXTRACTION UNITS SOUNDPROOFED DOUBLE-WALL OF SOUNDPROOFING 40 MM THICK CJSX- SILENT 400ºC/2h single-inlet belt-driven extraction units, in pre-lacquered sheet metal, double-wall

More information

CJBX CJBX/AL. Options. Order code CJBX 15/15 4. Technical characteristics

CJBX CJBX/AL. Options. Order code CJBX 15/15 4. Technical characteristics CJBX CJBX/AL CJBX: Belt-driven acoustically-insulated ventilation units. CJBX/AL: Belt-driven ventilation units with aluminium profiles and prefinished sheet steel and acoustic insulation. CJBX Options

More information

INDUSTRIAL BRUSHLESS MOTORS E.C. INDUSTRIAL EFFICIENT MOTORS IE3

INDUSTRIAL BRUSHLESS MOTORS E.C. INDUSTRIAL EFFICIENT MOTORS IE3 INDUSTRIAL MOTORS E.C. INDUSTRIAL EFFICIENT MOTORS IE3 OUR COMMITMENT TO THE ENVIRONMENT Sodeca has begun a new stage of study and design of new trends in ventilation which will help to preserve the environment

More information

Medium Pressure Centrifugal Fans

Medium Pressure Centrifugal Fans Medium Pressure Centrifugal Fans 2012 Edition ...About Axair Fans UK Application Knowledge: Over 20 years experience in general air movement; including corrosive, explosive and hot fume handling. Stock

More information

CENTRIFUGAL DIRECT DRIVE FANS CMT-CMB

CENTRIFUGAL DIRECT DRIVE FANS CMT-CMB CENTRIFUGAL DIRECT DRIVE FANS CMT-CMB Applications The CMT-CMB range of fans are suitable for many general and OEM ventilation applications where the extract of nonhazardous heated air is required. The

More information

Plate mounted axial flow fans HXBR / HXTR Series

Plate mounted axial flow fans HXBR / HXTR Series Plate mounted axial flow fans manufactured from high grade galvanised steel and provided with a Sickle blade impeller, low sound level, protected against corrosion by cataforesis primer and a polyester

More information

Series VENTS OVK. Low pressure axial fans in the steel casing with the air capacity up to m 3 /h for wall mounting

Series VENTS OVK. Low pressure axial fans in the steel casing with the air capacity up to m 3 /h for wall mounting AXIAL FANS Series VENTS OV Series VENTS OVK Series VENTS Low pressure axial fans in the steel casing with the air capacity up to 122 m 3 /h for wall mounting Low pressure axial fans in the steel casing

More information

CONTRA ROTATING CASED AXIAL FANS TCBBx2 / TCBTx2 Series

CONTRA ROTATING CASED AXIAL FANS TCBBx2 / TCBTx2 Series Range of cylindrical cased axial fans fitted with aluminium impellers and manufactured from high grade rolled galvanised steel and protected against corrosion by cataforesis primer and black polyester

More information

AAVC. Accessories HIGH PRESSURE FANS HIGH PRESSURE WITH BACKWARD IMPELLER MANUFACTURING FEATURES:

AAVC. Accessories HIGH PRESSURE FANS HIGH PRESSURE WITH BACKWARD IMPELLER MANUFACTURING FEATURES: AAVC HIGH PRESSURE WITH BACKWARD IMPELLER MANUFACTURING FEATURES: Accessories Fan made of Fe360 sheet. The fan paint finish is based on a Qualicoat polyester powder coating stoved at 200ºC, with an average

More information

WINDER. Impellers with higher efficiency and less sound level

WINDER. Impellers with higher efficiency and less sound level WINDER Impellers with higher efficiency and less sound level Winder Solutions The last new generation impeller With the Serrated Novovent Concept (S.N.C.), NOVOVENT, S.A. has developed a new blades generation.

More information

FRF FRF/EW ROOF-MOUNTED CENTRIFUGAL EXTRACTOR FAN WITH VERTICAL AIR OUTLET

FRF FRF/EW ROOF-MOUNTED CENTRIFUGAL EXTRACTOR FAN WITH VERTICAL AIR OUTLET FRF EXTERNAL ROTOR MOTOR ALUMINIUM STRUCTURE AND BOX THERMAL AND ACOUSTIC INSULATION BUILT-IN SAFETY SWITCH BUILT-IN WATER OUTLET DRAIN FRF/EW EFFICIENT WORK HIGH EFFICIENCY FAN E.C. BRUSHLESS INDUSTRIAL

More information

VORTICENT C E RANGE Centrifugal fans

VORTICENT C E RANGE Centrifugal fans NEW VORTICENT C E RANGE Centrifugal fans Suitable for domestic, commercial and industrial applications: kitchens, bathrooms, offices, laboratories, factories, shops, laundromats, models, restaurants, bars,

More information

HXBR / HXTR Series PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

HXBR / HXTR Series PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR HXBR / HXTR Series 0 017982 603075 A P P L I C A T I O N S Range of plate mounted axial fans manufactured from high grade galvanised steel

More information

COMPACT Series type HCFB / HCFT (Plastic impellers)

COMPACT Series type HCFB / HCFT (Plastic impellers) Plate mounted axial flow fans COMPACT HCFB/HCFT PLATE MOUNTED AXIAL FLOW FANS COMPACT Series type HCFB / HCFT (Plastic impellers) 0 017582 603079 Compact design Corrosion resistance Flame retardant terminal

More information

CMB / CMT Series CENTRIFUGAL SINGLE INLET FANS. Centrifugal direct drive fans CMB/CMT 80 C. Impeller dynamically balanced

CMB / CMT Series CENTRIFUGAL SINGLE INLET FANS. Centrifugal direct drive fans CMB/CMT 80 C. Impeller dynamically balanced CENTRIFUGAL SINGLE INLET FANS CMB / CMT Series 80 C CONTINUOUS operation Range of centrifugal single inlet fans suitable for continuous extraction of airstreams temperature up to 80ºC (Series 1) or 150ºC

More information

CENTRIFUGAL FANS IN-LINE DUCT EXTRACTORS CENTRIFUGAL FANS AND IN-LINE DUCT EXTRACTORS. According EU Regulation

CENTRIFUGAL FANS IN-LINE DUCT EXTRACTORS CENTRIFUGAL FANS AND IN-LINE DUCT EXTRACTORS. According EU Regulation CENTRIFUGAL FANS IN-LINE DUCT EXTRACTORS CENTRIFUGAL FANS AND IN-LINE DUCT EXTRACTORS According EU Regulation OUR COMMITMENT TO THE ENVIRONMENT Sodeca has begun a new stage of study and design of new trends

More information

RADIAL STEEL HIGH PRESSURE RHD 5/ RHD 4/ RHD 8/ RHD 11/ RHD 9/ RHD 13/ CAS... 8 CAM ACCESSORIES...

RADIAL STEEL HIGH PRESSURE RHD 5/ RHD 4/ RHD 8/ RHD 11/ RHD 9/ RHD 13/ CAS... 8 CAM ACCESSORIES... RADIAL STEEL HIGH PRESSURE RHD 5/10... 2 RHD 4/20... 3 RHD 8/25... 4 RHD 11/40... 5 RHD 9/60... 6 RHD 13/90... 7 CAS... 8... 14 ACCESSORIES... 18 1 RHD 5/10 A 230 / B 335 / C 385 / D 130 / E 140 / F 360

More information

supplied in Form (B) configuration. Airflow over Impeller- Motor.

supplied in Form (B) configuration. Airflow over Impeller- Motor. CYLINDRICAL CASED AXIAL FLOW FANS COMPACT Series TCBB-TCBT (Aluminium impellers) and TCFB-TCFT (Plastic impellers) NEW VERSIONS Description The S&P Cylindrical Cased Axial Fans feature, as the name suggests,

More information

PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR HXBR / HXTR Series. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR HXBR / HXTR Series. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance A P P L I C A T I O N S PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR HXBR / HXTR Series Range of plate mounted axial fans manufactured from high grade galvanised steel and provided with

More information

Short casing. Long casing (L version) Commercial premises

Short casing. Long casing (L version) Commercial premises CYLINDRICAL CASED AXIAL FLOW FANS TGT Series Adjustable Pitch Fans Long casing (L version) Short casing A P P L I C A T I O N S Range of adjustable pitch cased axial flow fans. Casings formed from rolled

More information

FONTECK INDUSTRIES Glasblazerstraat 12E, 2984 BL Ridderkerk, The Netherlands Tel: +31 (0) Fax: +31 (0)

FONTECK INDUSTRIES Glasblazerstraat 12E, 2984 BL Ridderkerk, The Netherlands Tel: +31 (0) Fax: +31 (0) Features: FONTECK INDUSTRIES AFBD AXIAL FAN (ATEX Certified, Gas Group IIB+H2) ATEX certified Comply with standard: EN 14986, EN13463 1 Driven directly by ATEX certified motor 15 sizes with case opening

More information

Performance. Sound Levels. Impellers. Motors. Accessories

Performance. Sound Levels. Impellers. Motors. Accessories EuroSeries (ESP) Die cast aluminium impellers Fully speed controllable Air Volumes up to 13.89m 3 /s Sizes 250 to 1000 dia protected to IP54 Operating Temperatures from -40 C up to +70 C Insulation Class

More information

CGT Series Adjustable Pitch Fans

CGT Series Adjustable Pitch Fans AXIAL FLOW CABINET FAN CGT Series Adjustable Pitch Fans New Ø 400-450-500 Range of adjustable pitch aerofoil blade, axial flow cabinet fans.fan casing manufactured from heavy gauge galvanised sheet steel

More information

CONTENTS. Page. Adjustable Axial Pitch Flow Fans 3. Dimensions 4. AP056 Performance Curves 5. AP056 Sound Performance 6. AP063 Performance Curves 7

CONTENTS. Page. Adjustable Axial Pitch Flow Fans 3. Dimensions 4. AP056 Performance Curves 5. AP056 Sound Performance 6. AP063 Performance Curves 7 CONTENTS Page Adjustable Axial Pitch Flow Fans 3 Dimensions 4 AP056 Performance Curves 5 AP056 Sound Performance 6 AP063 Performance Curves 7 AP063 Sound Performance 8 AP071Performance Curves 9 AP071 Sound

More information

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalouge

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalouge CENTRIFLOW 3D plug fan WITH AC MOTOR >> Technical catalouge air comfort Centriflow 3D 2 GMEB CentriFlow 3D - Technical Catalouge Contents GENERAL Description and survey chart Application... 3 General Survey

More information

CGT Series Adjustable Pitch Fans

CGT Series Adjustable Pitch Fans AXIAL FLOW CABINET FAN CGT Series Adjustable Pitch Fans New Ø 400-450-500 Range of adjustable pitch aerofoil blade, axial flow cabinet fans.fan casing manufactured from heavy gauge galvanised sheet steel

More information

ACOUSTIC CABINET FANS CVAB / CVAT Series

ACOUSTIC CABINET FANS CVAB / CVAT Series Range of in-line cabinet fans, manufactured from galvanised steel sheet with double thickness side panels internally lined with 17 mm thickness of fireproof fibreglass acoustic insulation (M). All models

More information

Axial fans. What s more, non-stock models are normally available within two weeks.

Axial fans. What s more, non-stock models are normally available within two weeks. Axial fans 7 sees the introduction of a new production line at Xpelair s Peterborough plant for the Scimitar Sickle blade fans in Plate, Short Case and Roof versions up to 63mm. Scimitar will join an impressive

More information

Heat recovery ventilators with rotating exchanger, automatic control and EC motor, designed for vertical ducts and installation in technical room

Heat recovery ventilators with rotating exchanger, automatic control and EC motor, designed for vertical ducts and installation in technical room RIRS V EKO Heat recovery ventilators with rotating exchanger, automatic control and EC motor, designed for vertical ducts and installation in technical room Common characteristics: Efficient low-noise

More information

BSB SINGLE INLET BELT DRIVEN CENTRIFUGAL FANS WITH BACKWARD CURVED IMPELLERS

BSB SINGLE INLET BELT DRIVEN CENTRIFUGAL FANS WITH BACKWARD CURVED IMPELLERS SINGLE INLET BELT DRIVEN CENTRIFUGAL FANS WITH BACKWARD CURVED IMPELLERS BSB 03.06-01 BSB SINGLE INLET BELT DRIVEN CENTRIFUGAL FANS WITH BACKWARD CURVED IMPELLERS Description Construction Fans are not

More information

CYLINDRICAL CASED AXIAL FLOW FANS

CYLINDRICAL CASED AXIAL FLOW FANS - Adjustable pitch fans Range of adjustable pitch aerofoil blade, cased axial flow fans. Casings formed from rolled sheet steel with a corrosion resistant hot dipped galvanised finish. All models incorporate

More information

IN-LINE CENTRIFUGAL DUCT FANS VT Series

IN-LINE CENTRIFUGAL DUCT FANS VT Series IN-LINE CENTRIFUGAL DUCT FANS VT Series DESCRIPTION The VT series of circular in-line duct centrifugal fans consists of model variations within nominal model sizes of,,,,, and mm respectively. The VT range

More information

Max. airflow m 3 /s Diam. min. Diam. max

Max. airflow m 3 /s Diam. min. Diam. max Axial Fans Max. airflow m 3 /s Diam. min Diam. max 1% adjustable motor Assembly, any position Reversible (3% Reduction) Page Number AW AR AW.97 2 3 * * 13 AR.97 2 3 * * 134 ZSP 2.9 315 5 * * 13 ZAP 13.89

More information

LOW-PRESSURE CENTRIFUGAL FANS WITH MULTI-BLADE OR BACKWARD-CURVED IMPELLERS. According EU Regulation

LOW-PRESSURE CENTRIFUGAL FANS WITH MULTI-BLADE OR BACKWARD-CURVED IMPELLERS. According EU Regulation LOW-PRESSURE CENTRIFUGAL FANS WITH MULTI-BLADE OR BACKWARD-CURVED IMPELLERS According EU Regulation OUR COMMITMENT TO THE ENVIRONMENT Sodeca has begun a new stage of study and design of new trends in ventilation

More information

CENTRIFUGAL IN-LINE FANS VENT Series

CENTRIFUGAL IN-LINE FANS VENT Series Range of in-line duct centrifugal fans, manufactured from high grade corrosion resistant pressed galvanised steel and supplied as standard with a prewired wiring junction box and a robust mounting foot.

More information

CHMT Series, F Rated Fans

CHMT Series, F Rated Fans CNTRIFUGAL SINGL INLT FANS CT Series, F400 120 Rated Fans Officially approved to N12101-3 standard (certificate number 0370-CPD-0348) Range of single inlet direct drive centrifugal fans designed for smoke

More information

VENT Series CENTRIFUGAL IN-LINE FANS VENT. In-Line duct fans. Mounting foot

VENT Series CENTRIFUGAL IN-LINE FANS VENT. In-Line duct fans. Mounting foot CENTRIFUGAL IN-LINE FANS Series Range of in-line duct centrifugal fans, manufactured from high grade corrosion resistant pressed galvanised steel and supplied as standard with a pre-wired wiring junction

More information

IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series

IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series Range of low profile in-line mixed flow duct fans manufactured in tough reinforced plastic (from 16 to 8 models) or with metal casing steel finished in a tough epoxy-polyester paint coating (from 1 to

More information

CRH RANGE - TECHNICAL DATA CENTRIFUGAL ROOF FANS

CRH RANGE - TECHNICAL DATA CENTRIFUGAL ROOF FANS ge 2 CENTRIFUGAL CRH RANGE - TECHNICAL ROOF DATA FANS FOR INDUSTRIAL / COMMERCIAL USE CRH - Horizontal Discharge CRV - Vertical Discharge CRL - Low Profile Uniclass L7534 Tel: +44 ()1494 522333 Fax: Vectaire

More information

In-Line Fans. Roof Fans. Fans ATEX. Centrifugal Fans. Chip Extractors. Domestic Fans. Accessories. Electric Diagrams. General Information.

In-Line Fans. Roof Fans. Fans ATEX. Centrifugal Fans. Chip Extractors. Domestic Fans. Accessories. Electric Diagrams. General Information. In-Line Fans xial-flow Fans Wall Versions xial-flow Fans Cased Versions Roof Fans Fans TEX Centrifugal Fans VISP/VSP Centrifugal Fans Side Channel lowers Chip Extractors COMPCT 44 TCx, TCTx FC 54 FC-V

More information

AATVP. Accessories HIGH PRESSURE FANS HIGH PRESSURE WITH BACKWARD IMPELLER AND BELT TRASMISSION MANUFACTURING FEATURES:

AATVP. Accessories HIGH PRESSURE FANS HIGH PRESSURE WITH BACKWARD IMPELLER AND BELT TRASMISSION MANUFACTURING FEATURES: AATVP HIGH PRESSURE WITH BACKWARD IMPELLER AND BELT TRASMISSION MANUFACTURING FEATURES: Accessories Fan made of Fe36 sheet. The fan paint finish is based on a Qualicoat polyester powder coating stoved

More information

BOX BLB Centrifugal Box Fan

BOX BLB Centrifugal Box Fan Centrifugal Box Fan Select models available for next day delivery Product Overview 3 sizes from 260mm to 400mm Air volume flow rates up to 0.751m³/s Static pressures up to 733 Pa Suitable for operating

More information

TD-MIXVENT Series IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT. In-Line duct fans

TD-MIXVENT Series IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT. In-Line duct fans IN-LINE MIXED FLOW DUCT FANS Series Range of low profile in-line mixed flow duct fans manufactured in tough reinforced plastic (from 160 to 800 models) or with metal casing steel finished in a tough epoxy-polyester

More information

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalogue

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalogue CENTRIFLOW 3D plug fan WITH AC MOTOR >> Technical catalogue air comfort Centriflow 3D 2 GMEB CentriFlow 3D - Technical Catalogue Contents GENERAL Description and survey chart Application... 3 General Survey

More information

CBM Small Series LOW PRESSURE CENTRIFUGAL FANS. CBM Small. Low pressure centrifugal fans. Impeller dynamically balanced.

CBM Small Series LOW PRESSURE CENTRIFUGAL FANS. CBM Small. Low pressure centrifugal fans. Impeller dynamically balanced. LOW PRESSURE CENTRIFUGAL FANS CBM Small Series Range of single and double inlet direct driven low pressure centrifugal fans manufactured from galvanised sheet steel and protected against corrosion by a

More information

Centriflow Plus EC. Technical data

Centriflow Plus EC. Technical data Technical data Centriflow Plus CTLOGUE Contents General description...3 General survey chart...4 Design description Fan Impeller...5 Inlet cone and supporting frame...5 EC motor...5 ir flow sensor...6

More information

IN-LINE DUCT FANS MIXVENT-TD Fan Systems

IN-LINE DUCT FANS MIXVENT-TD Fan Systems IN-LINE DUCT FANS MIXVENT-TD Fan Systems NEW TD-EXTRACTOR KIT (see page 175) MIXVENT TD / MIXVENT TD-T MIXVENT TDx2 ACCESSORIES Description Range Construction The MIXVENT system has been designed to compliment

More information

MTF. Technical features

MTF. Technical features Technical features Power supply Three-phase voltage from 24V to 690V, 50Hz or 60Hz or 100-130V, 60Hz and 200-240V, 50Hz ( types are supplied without capacitor); suitable for use with an inverter from 20Hz

More information

Axial-flow Fan AFC. Model numbering system AF C / T. Accessories Three phase. Power rate 1.

Axial-flow Fan AFC. Model numbering system AF C / T. Accessories Three phase. Power rate 1. xial-flow Fan FC Construction xial fan designed for installation in a ducted system. Casing of rolled and electro-welded steel sheet, powder coated RL5. Impeller in polypropylene. Casing in acid-proof

More information

ROOF MOUNTED AXIAL FLOW FANS HCTB / HCTT Series

ROOF MOUNTED AXIAL FLOW FANS HCTB / HCTT Series asy to install Supports to facilitate installation in the roof. XTRACTION (type B) SUPPLY (type A) High quality steel sleeve nsuring the long life of the fan. Range of axial roof fans with horizontal air

More information

CHVB / CHVT Series. Cabinet fans designed for smoke extraction in fire condition F BACKWARD CURVED CENTRIFUGAL FANS CHVB / CHVT

CHVB / CHVT Series. Cabinet fans designed for smoke extraction in fire condition F BACKWARD CURVED CENTRIFUGAL FANS CHVB / CHVT BACKWARD CURVED CENTRIFUGAL FANS Series The CHVB-CHVT range is suitable for many general ventilation applications where high system resistances are present; i.e. systems with filters, dampers etc. Range

More information

Energy-saving motors (ESM)

Energy-saving motors (ESM) Energy-saving motors (ESM) Technology Accessories EC-SYSTEMS ESM General information K series Q-motor EC axial EC axial fans A series fans Energy-saving motors (ESM) 316 Air performance curves 3 Energy-saving

More information

CBM Series LOW PRESSURE CENTRIFUGAL FANS CBM. Low pressure centrifugal fans. Impeller dynamically balanced. Anti-vibration mounts

CBM Series LOW PRESSURE CENTRIFUGAL FANS CBM. Low pressure centrifugal fans. Impeller dynamically balanced. Anti-vibration mounts LOW PRESSURE CENTRIFUGAL FANS Series Range of double inlet direct driven low pressure centrifugal fans manufactured from galvanised sheet steel. All the models are fitted with forward curved centrifugal

More information

Ultra-quiet circular duct fans TD-SILENT ECOWATT Series

Ultra-quiet circular duct fans TD-SILENT ECOWATT Series TD-SILENT ECOWATT - MODELS 5 to TD-SILENT ECOWATT - MODELS AND At 5% of full speed fan power consumption is reduced by 7% Low profile Mixed-flow fans with sound-absorbent insulation, extremely quiet, fan

More information

Uniclass L7534. Manufacture controlled to ISO9001

Uniclass L7534. Manufacture controlled to ISO9001 CABINET & TWIN FANS FOR INDUSTRIAL / COMMERCIAL USE "ACFS" - Quiet Duct Centrifugal - Single Fan "DMTSQ" - Quiet Duct Centrifugal - Twin Fan "RMS" - Roof Centrifugal - Single Fan "RMTS" - Roof Centrifugal

More information

CENTRIFLOW 3D WITH EC MOTOR >> Technical catalogue

CENTRIFLOW 3D WITH EC MOTOR >> Technical catalogue CENTRIFLOW 3D Plug Fan WITH EC MOTOR >> Technical catalogue air comfort CentriFlow 3D 2 GMEC CentriFlow 3D - Technical Catalogue Contents GENERL Description and survey chart pplication... 3 General Survey

More information

IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems

IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems MIXVENT TD / MIXVENT TD-T MIXVENT TDx2 ACCESSORIES Description Range Construction The MIXVENT system has been designed to compliment the MIXVENT-TD range

More information

FANS FOR ATEX EXPLOSIVE ATMOSPHERES AND OTHER APPLICATIONS C3H, C4H, C5M APPLICATIONS FOR: ATEX 94/9/CE ATEX EXPLOSIVE ATMOSPHERES NAVAL CONSTRUCTIONS

FANS FOR ATEX EXPLOSIVE ATMOSPHERES AND OTHER APPLICATIONS C3H, C4H, C5M APPLICATIONS FOR: ATEX 94/9/CE ATEX EXPLOSIVE ATMOSPHERES NAVAL CONSTRUCTIONS APPLICATIONS FOR: ATEX EXPLOSIVE ATMOSPHERES NAVAL CONSTRUCTIONS OFF-SHORE CHEMICAL INDUSTRY MINING AND PUBLIC WORKS FANS FOR ATEX EXPLOSIVE ATMOSPHERES AND OTHER APPLICATIONS ENERGY PLANTS AND WIND FARMS

More information

CVAB / CVAT Series ACOUSTIC CABINET FANS CVAB / CVAT. Acoustic cabinet fans. Backward curved centrifugal impellers.

CVAB / CVAT Series ACOUSTIC CABINET FANS CVAB / CVAT. Acoustic cabinet fans. Backward curved centrifugal impellers. ACOUSTIC CABINET FANS Series Range of in-line cabinet fans, manufactured from galvanised steel sheet with double thickness side panels internally lined with 17 mm thickness of fireproof fibreglass acoustic

More information

CYLINDRICAL CASED AXIAL FLOW FANS TGT Series - ADJUSTABLE PITCH FANS

CYLINDRICAL CASED AXIAL FLOW FANS TGT Series - ADJUSTABLE PITCH FANS - ADJUSTABLE PITCH FANS Range of adjustable pitch aerofoil blade, cased axial flow fans. Casings formed from rolled sheet steel with a corrosion resistant hot dip galvanised finish. All models incorporate

More information

MTF-E. Technical features

MTF-E. Technical features Technical features Power supply Threephase voltage from 220V to 690V, 50Hz or 60Hz; suitable for use with a PM inverter from 20Hz to the base frequency with constant torque load profile. Polarity 2 and

More information

Mixed Flow Roof Fans (RMH)

Mixed Flow Roof Fans (RMH) Mixed Flow Roof Fans (RMH) Motors protected to IP44 Motor insulation Class B Maximum operating temperature 4 C Standard Thermal Overload Protection IP65 service isolator Bird guard included as standard

More information

ACOUSTIC CABINET FANS CVB / CVT Series

ACOUSTIC CABINET FANS CVB / CVT Series Cabinet fans manufactured from heavy gauge galvanised steel sheet and internally lined with melamine foam flame retardant acoustic insulation (M1). All models incorporate double inlet single phase direct-drive

More information

TD-ECOWATT AND DECOR-ECOWATT Series

TD-ECOWATT AND DECOR-ECOWATT Series S&P presents its new ranges of domestic and commercial fans with DC motors TD-ECOWATT AND DECOR-ECOWATT Series Up to 55% savings in energy consumption Reduced CO 2 emissions Improvement of the environment

More information

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL 301 BEARINGS DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL 301 BEARINGS DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401 CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 202 PERFORMANCE CURVE 0.75 203 PERFORMANCE CURVE 1.00 204 PERFORMANCE CURVE 1.50 205 PERFORMANCE CURVE 2.00 206

More information

DIRECT-AIR ILB / ILT Series Rectangular duct fans

DIRECT-AIR ILB / ILT Series Rectangular duct fans IN-LINE DUCT FAN Series Rectangular duct fans Range of in-line rectangular duct fan manufactured from galvanised steel sheet and provided with an inspection cover that can be removed to access the motor/impeller

More information

Eco Mixed Flow (emf) Energy Saver. Terminal Box. Performance. Quality Assurance. Impellers. Accessories. Motors

Eco Mixed Flow (emf) Energy Saver. Terminal Box. Performance. Quality Assurance. Impellers. Accessories. Motors Eco Mixed Flow (emf) High efficiency Mixed Flow Fan with guide vanes Available in sizes 355 to 710mm dia. IP54 Fan rating (duct mounted) Operating temperatures up to 80 C (see technical specification)

More information

REVOLUTION SLCX Product Brochure

REVOLUTION SLCX Product Brochure REVOLUTION SLCX Brochure Available for next day delivery with ELTA SELECT ATEX Long Cased Axial Flow Fan For full detailed information on the following: Sound Data, Accessories & Wiring Data and Optimum

More information

CONTINUO. Radial centrifugal impeller. Radial centrifugal impellers dynamically balanced, according to ISO 1940 standard,

CONTINUO. Radial centrifugal impeller. Radial centrifugal impellers dynamically balanced, according to ISO 1940 standard, RADIAL CENTRIFUGAL FANS CBT-N Series CONTINUO Range of single inlet direct driven centrifugal fans designed for the continuous extraction of air stream up to 120ºC(1). The casings are manufactured from

More information

EDM Series EDM-80N EDM-80L EDM-100 EDM-200 AXIAL BATHROOM FANS. Bathroom extract fans EDM

EDM Series EDM-80N EDM-80L EDM-100 EDM-200 AXIAL BATHROOM FANS. Bathroom extract fans EDM AXIAL BATHROOM FANS EDM Series EDM-80N EDM-80L EDM-100 EDM-200 0 015982 603071 Installation examples Ceiling or wall mounting Extract ventilation through short duc extract ventilation Extract ventilation

More information

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL 301 BEARINGS DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL 301 BEARINGS DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401 CONTENTS Page - SPECIFICATIONS 200 PERFORMANCE RANGE and SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 202 PERFORMANCE CURVE 0.75 203 PERFORMANCE CURVE 1.00 204 PERFORMANCE CURVE 1.50 205 PERFORMANCE

More information

JM Aerofoil Multi-Stage 50 Hz

JM Aerofoil Multi-Stage 50 Hz JM Aerofoil Multi-Stage 5 Hz JM AEROFOIL - MULTI-STAGE CONTENTS Page: JM Aerofoil Multi-Stage - Introduction -5 Multi-Staging Motor Frame Size Schedules - Three Phase 7-8 Performance Curves SK1- SK135

More information

CMRT Series BACKWARD CURVED CENTRIFUGAL FANS. Backward curved centrifugal fans CMRT 80 C

CMRT Series BACKWARD CURVED CENTRIFUGAL FANS. Backward curved centrifugal fans CMRT 80 C BACKWARD CURVED CENTRIFUGAL FANS CMRT Series 80 C Continuous operation Range of single inlet direct drive centrifugal fans designed for continuous extraction of air stream up to 80ºC. Casings are manufactured

More information

IN-LINE CENTRIFUGAL FANS FOR INDUSTRIAL / COMMERCIAL USE

IN-LINE CENTRIFUGAL FANS FOR INDUSTRIAL / COMMERCIAL USE IN-LINE CENTRIFUGAL FANS FOR INDUSTRIAL / COMMERCIAL USE CIL - Centrifugal In-Line Fans SBAF - Slimbox Acoustic Fans ACF - Acoustic Cabinet Fans - Direct Drive ACFS - Super-Silent Acoustic Cabinet Fans

More information

Tube Fans - ESPADA Range ESPADA 100 (L) Features. Electrical Supply. Product Code. Sizes 100, 125, 150, 160, 200, 250 and 315

Tube Fans - ESPADA Range ESPADA 100 (L) Features. Electrical Supply. Product Code. Sizes 100, 125, 150, 160, 200, 250 and 315 Tube Fans - ESPADA Range Features mm to 315 mm diameter Air flow 18 m 3 /h (.5 m 3 /s) Static pressures up to 72 Pa Plastic cased centriugal fan Low noise levels Completely corrosion resistant Easy electrical

More information

MAJAX-2 GENERAL SPECIFICATION

MAJAX-2 GENERAL SPECIFICATION MAJAX-2 GENERAL SPECIFICATION Majax-2 axial flow fans are manufactured in diameters ranging from 315mm to 2000mm (available in 2250mm on request), and incorporate manually adjustable pitch aluminium bladed

More information