1 HCH HCT HCH HCT Order code Robust wall-mounted axial or long-cased fans Robust wall-mounted axial or long-cased fans, PL version supplied with plastic impeller and AL version supplied with aluminium impeller Fan: Airflow direction from motor to impeller PL version impellers in polyamide 6 reinforced with fibreglass and AL version in cast aluminium. HCT-40-2T and HCT-45-2T models only in AL version HCH: Support ring in sheet steel HCT: Sheet steel long casing with external terminal board Motor: IE2 efficiency motors for capacities equal to or over 0.75kW and below 7.5kW, except single-phase, 2 speed and 8 pole motors. IE3 efficiency motors for capacities equal to or over 7.5kW, except single-phase, 2 speed and 8 pole motors. Class F motors, with ball bearings and IP55 protection, except single-phase versions from size 45 to size 56, IP54 protection One-or two-speed depending on the model Single-phase 230V-50Hz and three-phase 230/400V-50Hz (up to 4kW) and 400/690V-50Hz (power over 4kW) Fan working temperature: -25ºC + 50ºC Finish: Anticorrosive finish in polyester resin polymerised at 190ºC, after alkaline degreasing with phosphate-free nanotechnology treatment. On request: IE2 and IE3 efficiency motors for any power. Airflow direction from impeller to motor. 100% reversible impellers. Special windings for different voltages. ATEX certification, Category 2 HCH 40 2T 1.5 PL PV HCH: Robust wall-mounted axial fans HCT: Robust long-cased axial fans Impeller diameter in cm. Number of motor poles 2=2900 r/min. 50 Hz 4=1400 r/min. 50 Hz 6=900 r/min. 50 Hz 8=750 r/min. 50 Hz 12=500 r/min. 50 Hz T=Three-phase Motor power M=Single-phase (HP) PL=Plastic PV=Distributor impeller AL=Aluminium impeller Technical characteristics Model Speed Maximum admissible current (A) Installed capacity Maximum airflow Sound pressure level Approx. weight (Kg) (r/min) 230V 400V 690V (kw) (m 3 /h) db(a) HCH HCT HCT 25-2T HCT 25-2M HCT 25-4T HCT 25-4M HCT 31-2T HCT 31-2M HCT 31-4T HCT 31-4M HCH HCT 35-2T HCT 35-2M HCH HCT 35-4T HCT 35-4M HCH HCT 40-2T HCH HCT 40-4T HCT 45-2T HCT 45-2T HCT 45-2/4T / / / / /73 33 HCH HCT 45-4T HCH HCT 45-4M HCH 45-6T HCH 45-6M
2 Technical characteristics Model Speed Maximum admissible current (A) Installed capacity Maximum airflow Sound pressure level Approx. weight (Kg) (r/min) 230V 400V 690V (kw) (m 3 /h) db(a) HCH HCT HCT 50-4T HCH HCT 56-4T HCH HCT 56-4M HCH HCT 56-4T HCH HCT 56-4/8T / / / / / HCH HCT 56-4T HCH HCT 56-4/8T / / / / / HCH HCT 56-4T HCH HCT 56-4/8T / / / / / HCH HCT 56-6T HCH HCT 56-6M HCH HCT 56-6T HCH HCT 56-6T HCH HCT 63-4T HCH HCT 63-4/8T / / / / / HCH HCT 63-4T HCH HCT 63-4/8T / / / / / HCH HCT 63-4T HCH HCT 63-4/8T / / / / / HCH HCT 63-4T HCH HCT 63-4/8T / / / / / HCH HCT 63-4T HCH HCT 63-4/8T / / / / / HCH HCT 63-6T HCH HCT 63-6M HCH HCT 63-6T HCH HCT 63-6T HCH HCT 63-6/12T / / / / / HCH HCT 71-4T HCH HCT 71-4/8T / / / / / HCH HCT 71-4T HCH HCT 71-4/8T / / / / / HCH HCT 71-4T HCH HCT 71-4/8T / / / / / HCH HCT 71-4T HCH HCT 71-4/8T / / / / / HCH HCT 71-6T HCH HCT 71-6M HCH HCT 71-6T HCH HCT 71-6/12T / / / / / HCH HCT 71-6T HCH HCT 71-6/12T / / / / / HCH HCT 80-4T HCH HCT 80-4/8T / / / / / HCH HCT 80-4T HCH HCT 80-4/8T / / / / / HCH HCT 80-4T HCH HCT 80-4/8T / / / / / HCH HCT 80-6T HCH HCT 80-6/12T / / / / / HCH HCT 80-6T HCH HCT 80-6/12T / / / / / HCH HCT 80-6T HCH HCT 80-6/12T / / / / / HCH HCT 80-6T HCH HCT 80-6/12T / / / / / HCH HCT 80-8T HCH HCT 80-8T HCH HCT 80-8T HCH HCT 90-4T HCH HCT 90-4/8T / / / / / HCH HCT 90-4T
3 Technical characteristics Model Speed Maximum admissible current (A) Installed capacity Maximum airflow Sound pressure level Approx. weight (Kg) (r/min) 230V 400V 690V (kw) (m 3 /h) db(a) HCH HCT HCH HCT 90-4/8T / / / / / HCH HCT 90-4T HCH HCT 90-4/8T / / / / / HCH HCT 90-4T-10 IE HCH HCT 90-4/8T / / / / / HCH HCT 90-6T HCH HCT 90-6/12T / / / / / HCH HCT 90-6T HCH HCT 90-6/12T / / / / / HCH HCT 90-6T HCH HCT 90-6/12T / / / / / HCH HCT 90-8T HCH HCT 90-8T HCH HCT 90-8T HCH HCT 90-8T HCH HCT 100-4T HCH HCT 100-4/8T / / / / / HCH HCT 100-4T-10 IE HCH HCT 100-4/8T / / / / / HCH HCT 100-4T-15 IE HCH HCT 100-4/8T / / / / / HCH HCT 100-4T-20 IE HCH HCT 100-4/8T / / / / / HCH HCT 100-6T HCH HCT 100-6/12T / / / / / HCH HCT 100-6T HCH HCT 100-6/12T / / / / / HCH HCT 100-6T HCH HCT 100-6/12T / / / / / HCH HCT 100-8T HCH HCT 100-8T HCH HCT 100-8T HCH HCT 100-8T Erp. BEP (best efficiency point) characteristics MC EC VSD SR Measurement category Efficiency category S Static T Total Variable-speed drive Specific relationship ηe[%] Efficiency N Degree of efficiency [kw] Electrical power [m 3 /h] Airflow [mmh 2 O] Static or total pressure (According to EC) [RPM] Speed Model MC EC VSD SR ηe [%] N [kw] [m3/h] [mmh 2 O] [RPM] 25-2T A S NO % M T T A S NO % M T M A S NO % T A S NO % M A S NO % T T-1.5 A S NO % T-0.33 A S NO % T-2 A S NO % T-3 A S NO % /4T-3 A S NO % T-0.5 A S NO % M-0.5 A S NO %
4 Erp. BEP (best efficiency point) characteristics Model MC EC VSD SR ηe [%] N [kw] [m3/h] [mmh 2 O] [RPM] 50-4T-0.75 B T NO % T-0.75 A S NO % M-0.75 A S NO % T-1 B T NO % /8T-1 B T NO % T-1.5 B T NO % /8T-1.5 B T NO % T-0.33 A S NO % T-1 C S NO % /8T-1 C S NO % T-1.5 C S NO % /8T-1.5 C S NO % T-2 C S NO % /8T-2 C S NO % T-3 B T NO % /8T-3 B T NO % T-4 B T NO % /8T-4 B T NO % T-0.5 C S NO % M-0.5 C S NO % T-0.75 C S NO % T-1.5 C S NO % /8T-1.5 C S NO % T-2 C S NO % /8T-2 C S NO % T-3 C S NO % /8T-3 C S NO % T-4 C S NO % /8T-4 C S NO % T-0.75 C S NO % M-0.75 C S NO % T-1 C S NO % /12T-1 C S NO % T-1.5 C S NO % /12T-1.5 C S NO % T-3 C S NO % /8T-3 C S NO % T-4 C S NO % /8T-4 C S NO % T-5.5 C S NO % /8T-5.5 C S NO % T-1 C S NO % /12T-1 C S NO % T-1.5 C S NO % /12T-1.5 C S NO % T-2 C S NO % /12T-2 C S NO % T-3 B T NO % /12T-3 B T NO % T-0.5 C S NO % T-0.75 C S NO % T-1 C S NO % T-4 C S NO % /8T-4 C S NO % T-5.5 C S NO % /8T-5.5 C S NO % T-7.5 C S NO % /8T-7.5 C S NO % T-10 IE3 C S NO % /8T-10 C S NO % T-2 C S NO % /12T-2 C S NO % T-3 C S NO % /12T-3 C S NO % T-4 B T NO % /12T-4 B T NO % T-1 C S NO % T-1.5 C S NO %
5 Erp. BEP (best efficiency point) characteristics Model MC EC VSD SR ηe [%] N [kw] [m3/h] [mmh 2 O] [RPM] 90-8T-2 C S NO % T-3 C S NO % T-7.5 C S NO % /8T-7.5 C S NO % T-10 IE3 C S NO % /8T-10 C S NO % T-15 IE3 C S NO % /8T-15 C S NO % T-20 IE3 C S NO % /8T-20 C S NO % T-3 C S NO % /12T-3 C S NO % T-4 C S NO % /12T-4 C S NO % T-5.5 C S NO % /12T-5.5 C S NO % T-1.5 C S NO % T-2 C S NO % Acoustic features The specified values are determined according to free field measurements of pressure and sound levels in db(a) at an equivalent distance of twice the fan s span plus the impeller s diameter, with a minimum of 1.5 m. Sound power Lw(A) spectrum in db(a) via frequency band in Hz. Model Model (2v) (2v) (2v) (2v) (2v) (2v) (2v) (2v) (2v) (2v) (2v) (2v) (2v) (2v) (2v) (2v) (2v) (2v) (2v) (2v) (2v) (2v) (2v) (2v) (2v) (2v) (2v) (2v) (2v) (2v) (2v) (2v) (2v) (2v) (2v) (2v) (2v)
6 Dimensions in mm HCH E Model ØA ØB ØC ØD F ØJ N HCH X 45º HCH X 45º HCH X 45º HCH X 45º HCH X 45º HCH X 45º HCH X 30º HCH X 30º HCH X 30º HCH X 30º HCH X 22º30 HCH X 22º30 HCH X 22º30 HCH X 22º30 HCH X 22º30 HCH X 22º30 HCH X 22º30 HCH X 22º30 HCH X 22º30 HCH X 22º30 HCH X 22º30 HCT Model ØA ØB ØD E E1 ØJ N HCT x90º HCT x90º HCT x45º HCT x45º HCT x45º HCT x30º HCT x30º HCT x30º HCT x22º30 HCT x22º30 HCT x22º30 HCT x22º30 HCT-100-4T x22º30 HCT-100-4T x22º30 32
7 Characteristic curves Q = Airflow in m 3 /h, m 3 /s and cfm. Pe= Static pressure in mmh 2 O, Pa and inwg. 2 Poles=3000 r/min 2 Poles=3000 r/min 4 Poles=1500 r/min 4 Poles=1500 r/min 4 Poles=1500 r/min 4 Poles=1500 r/min 33
8 Characteristic curves Q = Airflow in m 3 /h, m 3 /s and cfm. Pe= Static pressure in mmh 2 O, Pa and inwg. 4 Poles=1500 r/min 4 Poles=1500 r/min 4 Poles=1500 r/min 4 Poles=1500 r/min 6 Poles=1000 r/min 6 Poles=1000 r/min 34
9 Characteristic curves Q = Airflow in m 3 /h, m 3 /s and cfm. Pe= Static pressure in mmh 2 O, Pa and inwg. 6 Poles=1000 r/min 6 Poles=1000 r/min 6 Poles=1000 r/min 6 Poles=1000 r/min 8 Poles=750 r/min 8 Poles=750 r/min 35
10 Characteristic curves Q = Airflow in m 3 /h, m 3 /s and cfm. Pe= Static pressure in mmh 2 O, Pa and inwg. 4 Poles (2-speed motor)=2/4 Poles 8 Poles (2-speed motor)=4/8 Poles 8 Poles (2-speed motor) =4/8 Poles 8 Poles (2-speed motor)=4/8 Poles 8 Poles (2-speed motor)=4/8 Poles 8 Poles (2-speed motor)=4/8 Poles 36
11 Characteristic curves Q = Airflow in m 3 /h, m 3 /s and cfm. Pe= Static pressure in mmh 2 O, Pa and inwg. 8 Poles (2-speed motor) =4/8 Poles 12 Poles (2-speed motor)=6/12 Poles 12 Poles (2-speed motor)=6/12 Poles 12 Poles (2-speed motor)=6/12 Poles 12 Poles (2-speed motor)=6/12 Poles 12 Poles (2-speed motor)=6/12 Poles Accessories See accessories section. INT RM AR C2V VSD3/A-RFT CUADROS PL P PT/H R RI RT BTUB BAC PS VSD1/A-RFM S SI PV 37
Axial or tubular wall-mounted fans, PL version fitted with a plastic rotor and AL version with an aluminium rotor.
HCH HCH Extremely robust wall-mounted, axial or tubular fans Axial or tubular wall-mounted fans, PL version fitted with a plastic rotor and AL version with an aluminium rotor. Fan: Airflow direction from
More informationHCH-HCT/EW EFFICIENT WORK. Wall-mounted or long-cased axial fans fitted with high-efficiency IE3 asynchronous motor adjustable electronically.
HCH-HCT/EW AC HIGHLY EFFICIENT IE3-COMPLIANT THREE-PHASE MOTORS AC VARIABLE SPEED DRIVE VSD: Variable Speed Drive.. VSD1/A-RFM. VSD3/A-RFT Supply on request CONTROL Supply optional accesory SUPPLY VSD1/A-RFM:
More informationHCH/ATEX: Robust wall-mounted axial fans with ATEX certification HCT/ATEX: Robust long-cased axial fans with ATEX certification
HCH/ATEX HCT/ATEX HCH/ATEX: Robust wall-mounted axial fans with ATEX certification HCT/ATEX: Robust long-cased axial fans with ATEX certification Circular axial fans (HCH) or Long-cased fans (HCT) with
More informationMultifunctional roof fans for large flows. Multifunctional roof fans, highly robust construction, for large flows
HTMH Multifunctional roof fans for large flows Multifunctional roof fans, highly robust construction, for large flows Fan: Painted galvanised sheet steel base plate Turnable impellers cast aluminium. Protection
More information400ºC/2h centrifugal roof fans with horizontal or vertical air outlet CHT 200 4T BS. Installed capacity
400ºC/2h centrifugal roof fans with horizontal or vertical air outlet : 400ºC/2h centrifugal roof fans with horizontal air outlet, hood in aluminium : 400ºC/2h centrifugal roof fans with vertical air outlet,
More informationMultifunctional 400ºC/2h and 300ºC/2h roof fans
HTMF Multifunctional 400ºC/2h and 300ºC/2h roof fans Multifunctional 400ºC/2h ceiling fans to work inside fire danger zones, designed for smoke extraction in industrial or similar buildings. 0370-CPR-0544
More informationDynamically-balanced impellers with extremely robust cores CMP T 5.5
Medium pressure, single inlet centrifugal fans with sheet steel casing and impeller Fan: Sheet steel casing. Forward-curved impeller made of galvanised sheet steel. 38-2M model casing in cast aluminium.
More informationHigh-efficiency long-cased axial fans fitted industrial Brushless motor E.C. Fibreglass-reinforced plastic impeller.
HEPT/EW with High-efficiency long-cased axial fans fitted industrial Brushless motor E.C. BRUSHLESS MOTOR BRUSHLESS INDUSTRIAL E.C. Fibreglass-reinforced plastic impeller. Fan: Airflow direction from motor
More informationCAS 460 2T 7.5. Impeller size motor poles 2=3500 r/min. 60 Hz. Installed power
CAS CAS: High pressure, single inlet centrifugal fans with sheet steel casing and impeller : High pressure, single inlet centrifugal fans with sheet steel casing and impeller, fitted with acoustic attenuators
More information400ºC/2h and 300ºC/2h roof-mounted helical extractor fans with vertical air outlet
THT/ROOF ROOF-MOUNTED SMOKE EXTRACTOR FANS THT/ROOF 400ºC/2h and 300ºC/2h roof-mounted helical extractor fans with vertical air outlet Roof-mounted helical extractor fans with vertical air outlet, for
More informationCJBD/ALF CJBX/ALS CJBX/ALF CJBD/ALS VENTILATION UNITS WITH ALUMINIUM PROFILES. According EU Regulation
CJBD/AL CJBD/ALS CJBD/ALF CJBX/AL CJBX/ALS CJBX/ALF VENTILATION UNITS WITH ALUMINIUM PROFILES According EU Regulation CJBD/AL CJBD/ALS CJBD/ALF CJBD/AL: Soundproofed ventilation units with profiles in
More informationTHT/HATCH THT/HATCH. Order code THT/HATCH 40 2T 1 N 1 G
THT/HATCH High-powered ventilators with motorised opening and equipped with a roof fan, for smoke extraction in the event of a fire, 400ºC/2h High-powered ventilators with roof fan and motorised opening.
More informationCMR/EW EFFICIENT WORK
CMR/EW AC VARIABLE SPEED DRIVE VSD: Variable Speed Drive.. VSD1/A-RFM. VSD3/A-RFT Supply on request CONTROL Supply optional accesory SUPPLY VSD1/A-RFM: 220-240 V 50/60 Hz VSD3/A-RFT: 380-415 V 50/60 Hz
More informationAxial fans 400ºC/2h and 300ºC/2h With soundproofed box. Extraction units with axial fans to work inside fire danger zones.
CJTHT Axial fans 400ºC/2h and 300ºC/2h With soundproofed box Extraction units with axial fans to work inside fire danger zones. Fan: Sheet steel long casing fan. Galvanised sheet steel structure with thermal
More informationCMP/EW EFFICIENT WORK
CMP/EW High-efficiency centrifugal single-inlet, medium-pressure fans with a direct motor and impeller with forward-facing blades fitted with IE3 asynchronous motor adjustable electronically. AC HIGHLY
More informationCentrifugal medium-pressure fans fitted with multi-blade
CMP/ATEX CMP/ATEX impeller Centrifugal medium-pressure fans fitted with multi-blade with ATEX certification Centrifugal single-inlet, medium-pressure fans with casing and sheet steel impeller to work in
More informationHEAVY DUTY FANS FOR INDUSTRIAL APPLICATIONS
HEAVY DUTY FANS FOR INDUSTRIAL APPLICATIONS OUR COMMITMENT TO THE ENVIRONMENT Sodeca has begun a new stage of study and design of new trends in ventilation which will help to preserve the environment and
More informationCMP-L/EW B T D. Industrial Brushless Motors E.C. Motor power (CV) Three-phase VSD 400 V50/60 Hz. electrical power Maximum.
CMP-L/EW BRUSHLESS INDUSTRIAL BRUSHLESS MOTOR E.C. VARIABLE SPEED DRIVE VSD: Variable Speed Drive.. VSD1/B. VSD3/B Supply included with fan CONTROL Supply optional accesory SUPPLY VSD1/B: 220-240 V 50/60
More informationHIGH-POWERED VENTILATORS
HIGH-POWERED VENTILATORS WITH ROOF FANS 400ºC/2h The THT/HATCH series was designed using high-powered ventilator technology for smoke extraction in the event of a fire, and is equipped with THT series
More informationFans for ATEX EXPLOSIVE ATMOSPHERES
Fans for ATEX EXPLOSIVE ATMOSPHERES An ATEX area is a mixture of air and inflammable gas, the vapour of an inflammable liquid, a fog of combustible liquid or combustible powder, which, if they catch fire,
More informationTSAT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJTSA: Ventilation units with a forward-curved impeller.
TSA TSAT CJTSA TSA: Single inlet, belt-driven centrifugal fans with shaft outlet and forward-curved impeller. TSAT: Single inlet, belt-driven centrifugal fans fitted with electric motors, a set of pulleys
More informationUDT UDTX FILTRATION UNITS AND AIR TREATMENT MODULES
MF: Filtration Modules UDT ME: Modules with electrically heated coils MA: Modules with water coils UDTX UDT UDTX FILTRATION UNITS AND AIR TREATMENT MODULES According EU Regulation UDT UDT Soundproofed
More informationCRL. MADE OF SHEET STEEL TURBINE WITH REACTION BLADES LOW NOISE LEVEL IE3 > 0.75kw MOTORS ENERGY SAVING MOTORS CRL MEDIUM PRESSURE CENTRIFUGAL FANS
CRL MADE OF SHEET STEEL TURBINE WITH REACTION BLADES LOW NOISE LEVEL IE3 > 0.75kw MOTORS ENERGY SAVING MOTORS CRL MEDIUM PRESSURE CENTRIFUGAL FANS CRL Medium pressure, single-stage aspiration fans with
More informationCSXRT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJSXR: Ventilation units with a backward-curved impeller
CSXR CSXRT CJSXR CSXR: Belt-driven single inlet centrifugal fans with shaft outlet and backward-curved impeller CSXRT: Belt-driven single inlet centrifugal fans fitted with electric motors, a set of pulleys
More informationCJSX-SILENT 400º/2H BELT-DRIVEN EXTRACTION UNITS SOUNDPROOFED DOUBLE-WALL OF SOUNDPROOFING 40 MM THICK
CJSX-SILENT 400º/2H BELT-DRIVEN EXTRACTION UNITS SOUNDPROOFED DOUBLE-WALL OF SOUNDPROOFING 40 MM THICK CJSX- SILENT 400ºC/2h single-inlet belt-driven extraction units, in pre-lacquered sheet metal, double-wall
More informationCJBX CJBX/AL. Options. Order code CJBX 15/15 4. Technical characteristics
CJBX CJBX/AL CJBX: Belt-driven acoustically-insulated ventilation units. CJBX/AL: Belt-driven ventilation units with aluminium profiles and prefinished sheet steel and acoustic insulation. CJBX Options
More informationINDUSTRIAL BRUSHLESS MOTORS E.C. INDUSTRIAL EFFICIENT MOTORS IE3
INDUSTRIAL MOTORS E.C. INDUSTRIAL EFFICIENT MOTORS IE3 OUR COMMITMENT TO THE ENVIRONMENT Sodeca has begun a new stage of study and design of new trends in ventilation which will help to preserve the environment
More informationMedium Pressure Centrifugal Fans
Medium Pressure Centrifugal Fans 2012 Edition ...About Axair Fans UK Application Knowledge: Over 20 years experience in general air movement; including corrosive, explosive and hot fume handling. Stock
More informationCENTRIFUGAL DIRECT DRIVE FANS CMT-CMB
CENTRIFUGAL DIRECT DRIVE FANS CMT-CMB Applications The CMT-CMB range of fans are suitable for many general and OEM ventilation applications where the extract of nonhazardous heated air is required. The
More informationPlate mounted axial flow fans HXBR / HXTR Series
Plate mounted axial flow fans manufactured from high grade galvanised steel and provided with a Sickle blade impeller, low sound level, protected against corrosion by cataforesis primer and a polyester
More informationSeries VENTS OVK. Low pressure axial fans in the steel casing with the air capacity up to m 3 /h for wall mounting
AXIAL FANS Series VENTS OV Series VENTS OVK Series VENTS Low pressure axial fans in the steel casing with the air capacity up to 122 m 3 /h for wall mounting Low pressure axial fans in the steel casing
More informationCONTRA ROTATING CASED AXIAL FANS TCBBx2 / TCBTx2 Series
Range of cylindrical cased axial fans fitted with aluminium impellers and manufactured from high grade rolled galvanised steel and protected against corrosion by cataforesis primer and black polyester
More informationAAVC. Accessories HIGH PRESSURE FANS HIGH PRESSURE WITH BACKWARD IMPELLER MANUFACTURING FEATURES:
AAVC HIGH PRESSURE WITH BACKWARD IMPELLER MANUFACTURING FEATURES: Accessories Fan made of Fe360 sheet. The fan paint finish is based on a Qualicoat polyester powder coating stoved at 200ºC, with an average
More informationWINDER. Impellers with higher efficiency and less sound level
WINDER Impellers with higher efficiency and less sound level Winder Solutions The last new generation impeller With the Serrated Novovent Concept (S.N.C.), NOVOVENT, S.A. has developed a new blades generation.
More informationFRF FRF/EW ROOF-MOUNTED CENTRIFUGAL EXTRACTOR FAN WITH VERTICAL AIR OUTLET
FRF EXTERNAL ROTOR MOTOR ALUMINIUM STRUCTURE AND BOX THERMAL AND ACOUSTIC INSULATION BUILT-IN SAFETY SWITCH BUILT-IN WATER OUTLET DRAIN FRF/EW EFFICIENT WORK HIGH EFFICIENCY FAN E.C. BRUSHLESS INDUSTRIAL
More informationVORTICENT C E RANGE Centrifugal fans
NEW VORTICENT C E RANGE Centrifugal fans Suitable for domestic, commercial and industrial applications: kitchens, bathrooms, offices, laboratories, factories, shops, laundromats, models, restaurants, bars,
More informationHXBR / HXTR Series PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance
PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR HXBR / HXTR Series 0 017982 603075 A P P L I C A T I O N S Range of plate mounted axial fans manufactured from high grade galvanised steel
More informationCOMPACT Series type HCFB / HCFT (Plastic impellers)
Plate mounted axial flow fans COMPACT HCFB/HCFT PLATE MOUNTED AXIAL FLOW FANS COMPACT Series type HCFB / HCFT (Plastic impellers) 0 017582 603079 Compact design Corrosion resistance Flame retardant terminal
More informationCMB / CMT Series CENTRIFUGAL SINGLE INLET FANS. Centrifugal direct drive fans CMB/CMT 80 C. Impeller dynamically balanced
CENTRIFUGAL SINGLE INLET FANS CMB / CMT Series 80 C CONTINUOUS operation Range of centrifugal single inlet fans suitable for continuous extraction of airstreams temperature up to 80ºC (Series 1) or 150ºC
More informationCENTRIFUGAL FANS IN-LINE DUCT EXTRACTORS CENTRIFUGAL FANS AND IN-LINE DUCT EXTRACTORS. According EU Regulation
CENTRIFUGAL FANS IN-LINE DUCT EXTRACTORS CENTRIFUGAL FANS AND IN-LINE DUCT EXTRACTORS According EU Regulation OUR COMMITMENT TO THE ENVIRONMENT Sodeca has begun a new stage of study and design of new trends
More informationRADIAL STEEL HIGH PRESSURE RHD 5/ RHD 4/ RHD 8/ RHD 11/ RHD 9/ RHD 13/ CAS... 8 CAM ACCESSORIES...
RADIAL STEEL HIGH PRESSURE RHD 5/10... 2 RHD 4/20... 3 RHD 8/25... 4 RHD 11/40... 5 RHD 9/60... 6 RHD 13/90... 7 CAS... 8... 14 ACCESSORIES... 18 1 RHD 5/10 A 230 / B 335 / C 385 / D 130 / E 140 / F 360
More informationsupplied in Form (B) configuration. Airflow over Impeller- Motor.
CYLINDRICAL CASED AXIAL FLOW FANS COMPACT Series TCBB-TCBT (Aluminium impellers) and TCFB-TCFT (Plastic impellers) NEW VERSIONS Description The S&P Cylindrical Cased Axial Fans feature, as the name suggests,
More informationPLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR HXBR / HXTR Series. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance
A P P L I C A T I O N S PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR HXBR / HXTR Series Range of plate mounted axial fans manufactured from high grade galvanised steel and provided with
More informationShort casing. Long casing (L version) Commercial premises
CYLINDRICAL CASED AXIAL FLOW FANS TGT Series Adjustable Pitch Fans Long casing (L version) Short casing A P P L I C A T I O N S Range of adjustable pitch cased axial flow fans. Casings formed from rolled
More informationFONTECK INDUSTRIES Glasblazerstraat 12E, 2984 BL Ridderkerk, The Netherlands Tel: +31 (0) Fax: +31 (0)
Features: FONTECK INDUSTRIES AFBD AXIAL FAN (ATEX Certified, Gas Group IIB+H2) ATEX certified Comply with standard: EN 14986, EN13463 1 Driven directly by ATEX certified motor 15 sizes with case opening
More informationPerformance. Sound Levels. Impellers. Motors. Accessories
EuroSeries (ESP) Die cast aluminium impellers Fully speed controllable Air Volumes up to 13.89m 3 /s Sizes 250 to 1000 dia protected to IP54 Operating Temperatures from -40 C up to +70 C Insulation Class
More informationCGT Series Adjustable Pitch Fans
AXIAL FLOW CABINET FAN CGT Series Adjustable Pitch Fans New Ø 400-450-500 Range of adjustable pitch aerofoil blade, axial flow cabinet fans.fan casing manufactured from heavy gauge galvanised sheet steel
More informationCONTENTS. Page. Adjustable Axial Pitch Flow Fans 3. Dimensions 4. AP056 Performance Curves 5. AP056 Sound Performance 6. AP063 Performance Curves 7
CONTENTS Page Adjustable Axial Pitch Flow Fans 3 Dimensions 4 AP056 Performance Curves 5 AP056 Sound Performance 6 AP063 Performance Curves 7 AP063 Sound Performance 8 AP071Performance Curves 9 AP071 Sound
More informationCENTRIFLOW 3D WITH AC MOTOR >> Technical catalouge
CENTRIFLOW 3D plug fan WITH AC MOTOR >> Technical catalouge air comfort Centriflow 3D 2 GMEB CentriFlow 3D - Technical Catalouge Contents GENERAL Description and survey chart Application... 3 General Survey
More informationCGT Series Adjustable Pitch Fans
AXIAL FLOW CABINET FAN CGT Series Adjustable Pitch Fans New Ø 400-450-500 Range of adjustable pitch aerofoil blade, axial flow cabinet fans.fan casing manufactured from heavy gauge galvanised sheet steel
More informationACOUSTIC CABINET FANS CVAB / CVAT Series
Range of in-line cabinet fans, manufactured from galvanised steel sheet with double thickness side panels internally lined with 17 mm thickness of fireproof fibreglass acoustic insulation (M). All models
More informationAxial fans. What s more, non-stock models are normally available within two weeks.
Axial fans 7 sees the introduction of a new production line at Xpelair s Peterborough plant for the Scimitar Sickle blade fans in Plate, Short Case and Roof versions up to 63mm. Scimitar will join an impressive
More informationHeat recovery ventilators with rotating exchanger, automatic control and EC motor, designed for vertical ducts and installation in technical room
RIRS V EKO Heat recovery ventilators with rotating exchanger, automatic control and EC motor, designed for vertical ducts and installation in technical room Common characteristics: Efficient low-noise
More informationBSB SINGLE INLET BELT DRIVEN CENTRIFUGAL FANS WITH BACKWARD CURVED IMPELLERS
SINGLE INLET BELT DRIVEN CENTRIFUGAL FANS WITH BACKWARD CURVED IMPELLERS BSB 03.06-01 BSB SINGLE INLET BELT DRIVEN CENTRIFUGAL FANS WITH BACKWARD CURVED IMPELLERS Description Construction Fans are not
More informationCYLINDRICAL CASED AXIAL FLOW FANS
- Adjustable pitch fans Range of adjustable pitch aerofoil blade, cased axial flow fans. Casings formed from rolled sheet steel with a corrosion resistant hot dipped galvanised finish. All models incorporate
More informationIN-LINE CENTRIFUGAL DUCT FANS VT Series
IN-LINE CENTRIFUGAL DUCT FANS VT Series DESCRIPTION The VT series of circular in-line duct centrifugal fans consists of model variations within nominal model sizes of,,,,, and mm respectively. The VT range
More informationMax. airflow m 3 /s Diam. min. Diam. max
Axial Fans Max. airflow m 3 /s Diam. min Diam. max 1% adjustable motor Assembly, any position Reversible (3% Reduction) Page Number AW AR AW.97 2 3 * * 13 AR.97 2 3 * * 134 ZSP 2.9 315 5 * * 13 ZAP 13.89
More informationLOW-PRESSURE CENTRIFUGAL FANS WITH MULTI-BLADE OR BACKWARD-CURVED IMPELLERS. According EU Regulation
LOW-PRESSURE CENTRIFUGAL FANS WITH MULTI-BLADE OR BACKWARD-CURVED IMPELLERS According EU Regulation OUR COMMITMENT TO THE ENVIRONMENT Sodeca has begun a new stage of study and design of new trends in ventilation
More informationCENTRIFUGAL IN-LINE FANS VENT Series
Range of in-line duct centrifugal fans, manufactured from high grade corrosion resistant pressed galvanised steel and supplied as standard with a prewired wiring junction box and a robust mounting foot.
More informationCHMT Series, F Rated Fans
CNTRIFUGAL SINGL INLT FANS CT Series, F400 120 Rated Fans Officially approved to N12101-3 standard (certificate number 0370-CPD-0348) Range of single inlet direct drive centrifugal fans designed for smoke
More informationVENT Series CENTRIFUGAL IN-LINE FANS VENT. In-Line duct fans. Mounting foot
CENTRIFUGAL IN-LINE FANS Series Range of in-line duct centrifugal fans, manufactured from high grade corrosion resistant pressed galvanised steel and supplied as standard with a pre-wired wiring junction
More informationIN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series
Range of low profile in-line mixed flow duct fans manufactured in tough reinforced plastic (from 16 to 8 models) or with metal casing steel finished in a tough epoxy-polyester paint coating (from 1 to
More informationCRH RANGE - TECHNICAL DATA CENTRIFUGAL ROOF FANS
ge 2 CENTRIFUGAL CRH RANGE - TECHNICAL ROOF DATA FANS FOR INDUSTRIAL / COMMERCIAL USE CRH - Horizontal Discharge CRV - Vertical Discharge CRL - Low Profile Uniclass L7534 Tel: +44 ()1494 522333 Fax: Vectaire
More informationIn-Line Fans. Roof Fans. Fans ATEX. Centrifugal Fans. Chip Extractors. Domestic Fans. Accessories. Electric Diagrams. General Information.
In-Line Fans xial-flow Fans Wall Versions xial-flow Fans Cased Versions Roof Fans Fans TEX Centrifugal Fans VISP/VSP Centrifugal Fans Side Channel lowers Chip Extractors COMPCT 44 TCx, TCTx FC 54 FC-V
More informationAATVP. Accessories HIGH PRESSURE FANS HIGH PRESSURE WITH BACKWARD IMPELLER AND BELT TRASMISSION MANUFACTURING FEATURES:
AATVP HIGH PRESSURE WITH BACKWARD IMPELLER AND BELT TRASMISSION MANUFACTURING FEATURES: Accessories Fan made of Fe36 sheet. The fan paint finish is based on a Qualicoat polyester powder coating stoved
More informationBOX BLB Centrifugal Box Fan
Centrifugal Box Fan Select models available for next day delivery Product Overview 3 sizes from 260mm to 400mm Air volume flow rates up to 0.751m³/s Static pressures up to 733 Pa Suitable for operating
More informationTD-MIXVENT Series IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT. In-Line duct fans
IN-LINE MIXED FLOW DUCT FANS Series Range of low profile in-line mixed flow duct fans manufactured in tough reinforced plastic (from 160 to 800 models) or with metal casing steel finished in a tough epoxy-polyester
More informationCENTRIFLOW 3D WITH AC MOTOR >> Technical catalogue
CENTRIFLOW 3D plug fan WITH AC MOTOR >> Technical catalogue air comfort Centriflow 3D 2 GMEB CentriFlow 3D - Technical Catalogue Contents GENERAL Description and survey chart Application... 3 General Survey
More informationCBM Small Series LOW PRESSURE CENTRIFUGAL FANS. CBM Small. Low pressure centrifugal fans. Impeller dynamically balanced.
LOW PRESSURE CENTRIFUGAL FANS CBM Small Series Range of single and double inlet direct driven low pressure centrifugal fans manufactured from galvanised sheet steel and protected against corrosion by a
More informationCentriflow Plus EC. Technical data
Technical data Centriflow Plus CTLOGUE Contents General description...3 General survey chart...4 Design description Fan Impeller...5 Inlet cone and supporting frame...5 EC motor...5 ir flow sensor...6
More informationIN-LINE DUCT FANS MIXVENT-TD Fan Systems
IN-LINE DUCT FANS MIXVENT-TD Fan Systems NEW TD-EXTRACTOR KIT (see page 175) MIXVENT TD / MIXVENT TD-T MIXVENT TDx2 ACCESSORIES Description Range Construction The MIXVENT system has been designed to compliment
More informationMTF. Technical features
Technical features Power supply Three-phase voltage from 24V to 690V, 50Hz or 60Hz or 100-130V, 60Hz and 200-240V, 50Hz ( types are supplied without capacitor); suitable for use with an inverter from 20Hz
More informationAxial-flow Fan AFC. Model numbering system AF C / T. Accessories Three phase. Power rate 1.
xial-flow Fan FC Construction xial fan designed for installation in a ducted system. Casing of rolled and electro-welded steel sheet, powder coated RL5. Impeller in polypropylene. Casing in acid-proof
More informationROOF MOUNTED AXIAL FLOW FANS HCTB / HCTT Series
asy to install Supports to facilitate installation in the roof. XTRACTION (type B) SUPPLY (type A) High quality steel sleeve nsuring the long life of the fan. Range of axial roof fans with horizontal air
More informationCHVB / CHVT Series. Cabinet fans designed for smoke extraction in fire condition F BACKWARD CURVED CENTRIFUGAL FANS CHVB / CHVT
BACKWARD CURVED CENTRIFUGAL FANS Series The CHVB-CHVT range is suitable for many general ventilation applications where high system resistances are present; i.e. systems with filters, dampers etc. Range
More informationEnergy-saving motors (ESM)
Energy-saving motors (ESM) Technology Accessories EC-SYSTEMS ESM General information K series Q-motor EC axial EC axial fans A series fans Energy-saving motors (ESM) 316 Air performance curves 3 Energy-saving
More informationCBM Series LOW PRESSURE CENTRIFUGAL FANS CBM. Low pressure centrifugal fans. Impeller dynamically balanced. Anti-vibration mounts
LOW PRESSURE CENTRIFUGAL FANS Series Range of double inlet direct driven low pressure centrifugal fans manufactured from galvanised sheet steel. All the models are fitted with forward curved centrifugal
More informationUltra-quiet circular duct fans TD-SILENT ECOWATT Series
TD-SILENT ECOWATT - MODELS 5 to TD-SILENT ECOWATT - MODELS AND At 5% of full speed fan power consumption is reduced by 7% Low profile Mixed-flow fans with sound-absorbent insulation, extremely quiet, fan
More informationUniclass L7534. Manufacture controlled to ISO9001
CABINET & TWIN FANS FOR INDUSTRIAL / COMMERCIAL USE "ACFS" - Quiet Duct Centrifugal - Single Fan "DMTSQ" - Quiet Duct Centrifugal - Twin Fan "RMS" - Roof Centrifugal - Single Fan "RMTS" - Roof Centrifugal
More informationCENTRIFLOW 3D WITH EC MOTOR >> Technical catalogue
CENTRIFLOW 3D Plug Fan WITH EC MOTOR >> Technical catalogue air comfort CentriFlow 3D 2 GMEC CentriFlow 3D - Technical Catalogue Contents GENERL Description and survey chart pplication... 3 General Survey
More informationIN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems
IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems MIXVENT TD / MIXVENT TD-T MIXVENT TDx2 ACCESSORIES Description Range Construction The MIXVENT system has been designed to compliment the MIXVENT-TD range
More informationFANS FOR ATEX EXPLOSIVE ATMOSPHERES AND OTHER APPLICATIONS C3H, C4H, C5M APPLICATIONS FOR: ATEX 94/9/CE ATEX EXPLOSIVE ATMOSPHERES NAVAL CONSTRUCTIONS
APPLICATIONS FOR: ATEX EXPLOSIVE ATMOSPHERES NAVAL CONSTRUCTIONS OFF-SHORE CHEMICAL INDUSTRY MINING AND PUBLIC WORKS FANS FOR ATEX EXPLOSIVE ATMOSPHERES AND OTHER APPLICATIONS ENERGY PLANTS AND WIND FARMS
More informationCVAB / CVAT Series ACOUSTIC CABINET FANS CVAB / CVAT. Acoustic cabinet fans. Backward curved centrifugal impellers.
ACOUSTIC CABINET FANS Series Range of in-line cabinet fans, manufactured from galvanised steel sheet with double thickness side panels internally lined with 17 mm thickness of fireproof fibreglass acoustic
More informationCYLINDRICAL CASED AXIAL FLOW FANS TGT Series - ADJUSTABLE PITCH FANS
- ADJUSTABLE PITCH FANS Range of adjustable pitch aerofoil blade, cased axial flow fans. Casings formed from rolled sheet steel with a corrosion resistant hot dip galvanised finish. All models incorporate
More informationMTF-E. Technical features
Technical features Power supply Threephase voltage from 220V to 690V, 50Hz or 60Hz; suitable for use with a PM inverter from 20Hz to the base frequency with constant torque load profile. Polarity 2 and
More informationMixed Flow Roof Fans (RMH)
Mixed Flow Roof Fans (RMH) Motors protected to IP44 Motor insulation Class B Maximum operating temperature 4 C Standard Thermal Overload Protection IP65 service isolator Bird guard included as standard
More informationACOUSTIC CABINET FANS CVB / CVT Series
Cabinet fans manufactured from heavy gauge galvanised steel sheet and internally lined with melamine foam flame retardant acoustic insulation (M1). All models incorporate double inlet single phase direct-drive
More informationTD-ECOWATT AND DECOR-ECOWATT Series
S&P presents its new ranges of domestic and commercial fans with DC motors TD-ECOWATT AND DECOR-ECOWATT Series Up to 55% savings in energy consumption Reduced CO 2 emissions Improvement of the environment
More information- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL 301 BEARINGS DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401
CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 202 PERFORMANCE CURVE 0.75 203 PERFORMANCE CURVE 1.00 204 PERFORMANCE CURVE 1.50 205 PERFORMANCE CURVE 2.00 206
More informationDIRECT-AIR ILB / ILT Series Rectangular duct fans
IN-LINE DUCT FAN Series Rectangular duct fans Range of in-line rectangular duct fan manufactured from galvanised steel sheet and provided with an inspection cover that can be removed to access the motor/impeller
More informationEco Mixed Flow (emf) Energy Saver. Terminal Box. Performance. Quality Assurance. Impellers. Accessories. Motors
Eco Mixed Flow (emf) High efficiency Mixed Flow Fan with guide vanes Available in sizes 355 to 710mm dia. IP54 Fan rating (duct mounted) Operating temperatures up to 80 C (see technical specification)
More informationREVOLUTION SLCX Product Brochure
REVOLUTION SLCX Brochure Available for next day delivery with ELTA SELECT ATEX Long Cased Axial Flow Fan For full detailed information on the following: Sound Data, Accessories & Wiring Data and Optimum
More informationCONTINUO. Radial centrifugal impeller. Radial centrifugal impellers dynamically balanced, according to ISO 1940 standard,
RADIAL CENTRIFUGAL FANS CBT-N Series CONTINUO Range of single inlet direct driven centrifugal fans designed for the continuous extraction of air stream up to 120ºC(1). The casings are manufactured from
More informationEDM Series EDM-80N EDM-80L EDM-100 EDM-200 AXIAL BATHROOM FANS. Bathroom extract fans EDM
AXIAL BATHROOM FANS EDM Series EDM-80N EDM-80L EDM-100 EDM-200 0 015982 603071 Installation examples Ceiling or wall mounting Extract ventilation through short duc extract ventilation Extract ventilation
More information- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL 301 BEARINGS DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401
CONTENTS Page - SPECIFICATIONS 200 PERFORMANCE RANGE and SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 202 PERFORMANCE CURVE 0.75 203 PERFORMANCE CURVE 1.00 204 PERFORMANCE CURVE 1.50 205 PERFORMANCE
More informationJM Aerofoil Multi-Stage 50 Hz
JM Aerofoil Multi-Stage 5 Hz JM AEROFOIL - MULTI-STAGE CONTENTS Page: JM Aerofoil Multi-Stage - Introduction -5 Multi-Staging Motor Frame Size Schedules - Three Phase 7-8 Performance Curves SK1- SK135
More informationCMRT Series BACKWARD CURVED CENTRIFUGAL FANS. Backward curved centrifugal fans CMRT 80 C
BACKWARD CURVED CENTRIFUGAL FANS CMRT Series 80 C Continuous operation Range of single inlet direct drive centrifugal fans designed for continuous extraction of air stream up to 80ºC. Casings are manufactured
More informationIN-LINE CENTRIFUGAL FANS FOR INDUSTRIAL / COMMERCIAL USE
IN-LINE CENTRIFUGAL FANS FOR INDUSTRIAL / COMMERCIAL USE CIL - Centrifugal In-Line Fans SBAF - Slimbox Acoustic Fans ACF - Acoustic Cabinet Fans - Direct Drive ACFS - Super-Silent Acoustic Cabinet Fans
More informationTube Fans - ESPADA Range ESPADA 100 (L) Features. Electrical Supply. Product Code. Sizes 100, 125, 150, 160, 200, 250 and 315
Tube Fans - ESPADA Range Features mm to 315 mm diameter Air flow 18 m 3 /h (.5 m 3 /s) Static pressures up to 72 Pa Plastic cased centriugal fan Low noise levels Completely corrosion resistant Easy electrical
More informationMAJAX-2 GENERAL SPECIFICATION
MAJAX-2 GENERAL SPECIFICATION Majax-2 axial flow fans are manufactured in diameters ranging from 315mm to 2000mm (available in 2250mm on request), and incorporate manually adjustable pitch aluminium bladed
More information