Unit s 1 & New Berlin Road No.109 Jacksonville, Florida Global Power Generation Services, All Rights Reserved.

Size: px
Start display at page:

Download "Unit s 1 & New Berlin Road No.109 Jacksonville, Florida Global Power Generation Services, All Rights Reserved."

Transcription

1 Unit s 1 & 2

2

3

4 Turbine Generator Inspections Summary Unit s 1 & 2 are of the same design; Single Flow Condensing Steam Turbine with Hydrogen Cooled Generators, both sets are installed on an outdoor pedestal arrangement. The Turbines Generators Enclosures and Appearance Lagging is all in very good condition with little corrosion if any near the structural foundation connections. Visual inspection of the Low Pressure Turbine (LP) revealed very little water erosion on the turbine blades and the case, coupling and exhaust hood were all found in good condition. The Throttle Control Valves are all in good condition with albeit a film of surface corrosion is present on carbon steel components. The generator stator winding end turns and field coils were visually inspected with an industrial Videoscope and no abnormal conditions were detected. Photos Unit No. 1 Unit No. 2

5 Unit No. 1 Front Standard Unit No. 2 Extraction Valve Control Control Valves

6 Unit No. 1 Exhaust Hood Unit No. 2 Collector / Exciter End

7 Unit No. 1 Low Pressure Turbine Blades LP Bucket (Blade) Covers and Tenons LP Bucket Tie-Wire LP Bucket Leading and Trialing Edges, Indicator of Water Erosion

8 Unit No. 2 Low Pressure Turbine Blades LP Bucket (Blade) Covers and Tenons LP Bucket Tie-Wire LP Bucket Leading and Trialing Edges, Indicator of Water Erosion

9 Unit No. 1 Generator Borescope Generator Stator High Voltage Connection and Bushing Generator Stator Winding End Turns Generator Stator Wedges

10 Generator Field Wedges, Green Glass Top Insulation Generator Field Wedges

11 Unit No. 2 Generator Borescope Generator Stator High Voltage Bushings Generator Stator Winding End Turns Generator Stator Wedges

12 Generator Field Coil Wedges Generator Field Coil Wedges

13 Unit 3 & 4

14

15

16 Turbine Generator Inspections Summary Unit s 3 & 4 are of the same design; Double Flow LP Condensing Steam Turbines with Hydrogen Cooled Generators, both units are installed end to end on an outdoor pedestal arrangement. The Turbines Generators Enclosures and Appearance Lagging is all in very good condition with little corrosion if any near the structural foundation connections. Visual inspection of the Double Flow Low Pressure Turbine (LP) revealed very little water erosion on the turbine blades and the case, coupling and exhaust hood were all found in good condition. The Control Valves are all in good condition with albeit a film of surface corrosion is present on carbon steel components. The generator stator winding end turns and field coils were visually inspected with an industrial Videoscope and no abnormal conditions were detected. Photos Unit No. 3 Unit No. 4

17 Unit No. 3 Front Standard Unit No. 4 Extraction Valve Control

18 Unit No. 3 Exhaust Hood Unit No. 4 Collector / Exciter End

19 Unit No. 3 Low Pressure Turbine Blades LP Bucket (Blade) Covers and Tenons LP Bucket Tie-Wire LP Bucket Leading and Trialing Edges

20 Unit No. 4 Low Pressure Turbine Blades LP Bucket (Blade) Covers and Tenons LP Bucket Tie-Wire LP Bucket Leading and Trialing Edges

21 Unit No. 3 Generator Borescope Generator Stator Winding End Turns Generator Stator Wedges

22 Generator Field Coil End Turns Generator Field Coil End Turns

23 Unit No. 4 Generator Borescope Generator Stator Wedges Generator Field Wedges

24 Generator Field Coil End Turns Generator Field Coil End Turns

Worldwide repair and services on motors, generators and transformers

Worldwide repair and services on motors, generators and transformers Worldwide repair and services on motors, generators and transformers Bakker Repair + Services, your partner for worldwide repair and services Bakker Repair + Services has 40 years of experience in repair

More information

Inspection Testing Repair

Inspection Testing Repair Inspection Testing Repair Generator Technical Services 1810 Blackwell Lane Penascola, FL 32514 Phone (850) 471-1101 Fax (850) 471-1104 Email: info@gentechservices.com Power Generation Generator Technical

More information

Excitation system is of Static Silicon Excitation System, including excitation transformer, thyristors, and AVR.

Excitation system is of Static Silicon Excitation System, including excitation transformer, thyristors, and AVR. Turbo - Generator Type: QF Series 1. General The generator is a two pole, cylindrical rotor type synchronous machine, directly coupled with steam turbine. It has a closed-circuit cooling system to cool

More information

Dynamic Balancing. Need a high-speed balance? No problem.

Dynamic Balancing. Need a high-speed balance? No problem. Dynamic Balancing TOSHIBA is one of North America s leading turbine/generator service providers. Our unique highspeed balance and overspeed facility assures that proper balance is achieved prior to returning

More information

BRUSHLESS EXCITERS FOR TURBINE GENERATORS

BRUSHLESS EXCITERS FOR TURBINE GENERATORS BRUSHLESS EXCITERS FOR TURBINE GENERATORS Economical, Manpower Saving Exciters Based on State-of-the-Art Technology. Mitsubishi Electrical manufactures brushless exciters for all types of turbine generator,

More information

Marine Industry Offshore Rail. Worldwide repair and services on generators, electromotors and transformers. We take care of it

Marine Industry Offshore Rail. Worldwide repair and services on generators, electromotors and transformers. We take care of it Marine Industry Offshore Rail Worldwide repair and services on generators, electromotors and transformers We take care of it Bakker Repair + Services, your partner for worldwide repair and services Bakker

More information

First Quality Solutions

First Quality Solutions First Quality Solutions Turbine Inspection Reports www.firstqualitysolutions.org VISUAL EXAMINATION REPORT Customer: Sample Turbine Outage PO: 104568912 Report No: S1 Component: Turbine Components WO:

More information

93 MWe natural gas fired Combined Cycle Power Plant

93 MWe natural gas fired Combined Cycle Power Plant 93 MWe natural gas fired Combined Cycle Power Plant 1. Power Plant General Description This is a Combined Cycle Cogeneration Power Plant (CCCPP) located in (Milan) able to supply about 30 t/h of surplus

More information

Pressurized Air Cooled Generators

Pressurized Air Cooled Generators PGI Orlando Dec. 13, 2016 Pressurized Air Cooled Generators Mike Zborovsky New App Generator Portfolio Owner siemens.com Pressurized Air-Cooled Generator (SGenX-2000P) Table of content Introduction 3 Portfolio

More information

Power Factor Improvement

Power Factor Improvement Power Factor Improvement The following devices and equipments are used for Power Factor Improvement. Static Capacitor Synchronous Condenser Phase Advancer 1. Static Capacitor We know that most of the industries

More information

Global VPI Insulated Indirectly Hydrogen-Cooled Turbine Generator for Single-Shaft Type Combined Cycle Power Generation Facilities

Global VPI Insulated Indirectly Hydrogen-Cooled Turbine Generator for Single-Shaft Type Combined Cycle Power Generation Facilities Global VPI Insulated Indirectly Hydrogen-Cooled Turbine Generator for Single-Shaft Type Combined Cycle Power Generation Facilities YAMAZAKI Masaru NIIKURA Hitoshi TANIFUJI Satoshi ABSTRACT Fuji Electric

More information

Preliminary Report. 19 October, For. Burak Marine. Aliağa İzmir TURKEY ESN Under. Mehmet AKIN (Granite)

Preliminary Report. 19 October, For. Burak Marine. Aliağa İzmir TURKEY ESN Under. Mehmet AKIN (Granite) Preliminary Report 19 October, 2012 For Burak Marine Aliağa İzmir TURKEY ESN 456-675 Under Customer Representative: GE Field Service Representative: Burak ALDEMİR Adnan LEBLEBİCİ Mehmet AKIN (Granite)

More information

STEAM TURBINE MODERNIZATION SOLUTIONS PROVIDE A WIDE SPECTRUM OF OPTIONS TO IMPROVE PERFORMANCE

STEAM TURBINE MODERNIZATION SOLUTIONS PROVIDE A WIDE SPECTRUM OF OPTIONS TO IMPROVE PERFORMANCE STEAM TURBINE MODERNIZATION SOLUTIONS PROVIDE A WIDE SPECTRUM OF OPTIONS TO IMPROVE PERFORMANCE Michael W. Smiarowski, Rainer Leo, Christof Scholten, Siemens Power Generation (PG), Germany John Blake,

More information

Generator. Jason S DiSanto. 6B Users Conference San Antonio, TX June 19-22, 2017

Generator. Jason S DiSanto. 6B Users Conference San Antonio, TX June 19-22, 2017 Generator Jason S DiSanto 6B Users Conference San Antonio, TX June 19-22, 2017 GE Power 2017, General Electric Company. GE Proprietary Information - The information contained in this document is General

More information

Vibration Diagnostic Software. Proven Automated Diagnostic Technology for Machinery Condition Assessment

Vibration Diagnostic Software. Proven Automated Diagnostic Technology for Machinery Condition Assessment Vibration Diagnostic Software Proven Automated Diagnostic Technology for Machinery Condition Assessment CLOUD SUPPORTED IIoT Successful programs require more collaborates to contribute to the understanding

More information

High Voltage Generators. TM21-TG Series. 2-Pole Air Cooled Turbine Generator Up to 80,000 kw (107,000 HP)

High Voltage Generators. TM21-TG Series. 2-Pole Air Cooled Turbine Generator Up to 80,000 kw (107,000 HP) High Voltage Generators TM21-TG Series 2-Pole Air Cooled Turbine Generator Up to 80,000 kw (107,000 HP) TMEIC has a proud and rich history of providing the latest generator technology for a broad range

More information

Preliminary Report. 17 October, For. Burak Marine. Aliağa İzmir TURKEY ESN Mehmet AKIN (Granite)

Preliminary Report. 17 October, For. Burak Marine. Aliağa İzmir TURKEY ESN Mehmet AKIN (Granite) Preliminary Report 17 October, 2012 For Burak Marine Aliağa İzmir TURKEY ESN 560-040 Customer Representative: GE Field Service Representative: Burak ALDEMİR Adnan LEBLEBİCİ Mehmet AKIN (Granite) All technical

More information

Configuration of a generator

Configuration of a generator Configuration of a generator Machinery Generator assembly, outline of generator Functional 1 Describe processes. Prepositions and verbs Suez Manual Guillermo Montoya G. Color: None Duplex: 1-4 What is

More information

BHARAT ALUMINIUM COMPANY LTD. SPECIFICATIONS FOR SYNCHRONOUS GENERATOR GENERAL Make : Jinan Power Equipment Factory Type : WX2

BHARAT ALUMINIUM COMPANY LTD. SPECIFICATIONS FOR SYNCHRONOUS GENERATOR GENERAL Make : Jinan Power Equipment Factory Type : WX2 BHARAT ALUMINIUM COMPANY LTD. SPECIFICATIONS FOR SYNCHRONOUS GENERATOR 1.00.00 GENERAL 1.01.00 Make : Jinan Power Equipment Factory 1.02.00 Type : WX21Z-073LLT 1.03.00 Reference Standard : GB/T7064-2002

More information

Carbon Brush Performance on Slip Rings

Carbon Brush Performance on Slip Rings Carbon Brush Performance on Slip Rings Richard D. Hall Morgan AM&T Roland P. Roberge Morgan AM&T Gary Lozowski Morgan AM&T Mining Electrical Maintenance and Safety Association September 9, 2010 Clearwater,

More information

MINI PACK BUILD SPEC. 885 ESN: FA0278 TSN: 15, CSN: 15,815 TSO: N/A CSO: N/A TSHSI: 2, CSHSI: 2,373 RGB SN. FA0278

MINI PACK BUILD SPEC. 885 ESN: FA0278 TSN: 15, CSN: 15,815 TSO: N/A CSO: N/A TSHSI: 2, CSHSI: 2,373 RGB SN. FA0278 MINI PACK ENGINE Model: BUILD SPEC. 885 ESN: PW150A FA0278 TSN: 15,012.30 CSN: 15,815 TSO: N/A CSO: N/A TSHSI: 2,056.00 CSHSI: 2,373 RGB SN. FA0278 TSN: 15,012.30 CSN: 15,815 TSO: 3,596.40 CSO: 3,863 CONTENTS:

More information

34 th Hands-On Relay School

34 th Hands-On Relay School 34 th Hands-On Relay School Generation Track Overview Lecture Generator Design, Connections, and Grounding 1 Generator Main Components Stator Core lamination Winding Rotor Shaft Poles Slip rings Stator

More information

Chromalloy. Borescope and Test Report. Prepared for. Triumph Air Repair A Triumph Group Company

Chromalloy. Borescope and Test Report. Prepared for. Triumph Air Repair A Triumph Group Company A Triumph Group Company Borescope and Test Report Prepared for Chromalloy Customer P.O.#: S2669 A.P.U. Model #: GTCP331-200ER A.P.U. Serial #: P-2796 A.P.U. Part #: 3800298-1 Triumph SRO #: S000013678

More information

Photographs of large cities, such as Seattle, Washington, are visible reminders of how much people rely on electrical energy.

Photographs of large cities, such as Seattle, Washington, are visible reminders of how much people rely on electrical energy. Photographs of large cities, such as Seattle, Washington, are visible reminders of how much people rely on electrical energy. Generating Electric Current How is voltage induced in a conductor? According

More information

EnVibe, Inc. Houston, Texas. Carbon Seal Rub on a Steam Turbine

EnVibe, Inc. Houston, Texas. Carbon Seal Rub on a Steam Turbine Case History: Carbon Seal Rub on a Steam Turbine Joe McCollum EnVibe, Inc. Houston, Texas Summary This article describes the effects and vibration responses when carbon seal rubs are experienced on a steam

More information

M50 L50 Series - 50Hz Metric Edition Multistage Regenerative Turbine Pumps

M50 L50 Series - 50Hz Metric Edition Multistage Regenerative Turbine Pumps Page M-M MTH PUMPS M L Series - Hz Metric Edition Multistage Regenerative Turbine Pumps Capacities to LPM Heads to 6 Meters Single or Multi-stage Units (up to stages) Vertical Close Coupled Horizontal

More information

NEIL Turbine Generator Risk Assessment. Todd Raymond Loss Risk Analysis Manager Nuclear Service Organization April 16-17, 2013

NEIL Turbine Generator Risk Assessment. Todd Raymond Loss Risk Analysis Manager Nuclear Service Organization April 16-17, 2013 NEIL Turbine Generator Risk Assessment Todd Raymond Loss Risk Analysis Manager Nuclear Service Organization April 16-17, 2013 Program Origin Large Losses due to Turbine Generator Failures in recent years

More information

Appendix B6 Gas Turbine Unit Cause Codes

Appendix B6 Gas Turbine Unit Cause Codes Appendix B6 Gas Turbine Unit Cause Codes GAS TURBINE UNITS INDEX TO SYSTEM/COMPONENT CAUSE CODES (Unit Codes 300 399 and 700 799) Cause Code BALANCE OF PLANT Ranges Page No. GENERATOR GAS TURBINE Electrical

More information

Mohammad Faisal Haider. Department of Mechanical Engineering Bangladesh University of Engineering and Technology

Mohammad Faisal Haider. Department of Mechanical Engineering Bangladesh University of Engineering and Technology Mohammad Faisal Haider Lecturer Department of Mechanical Engineering Bangladesh University of Engineering and Technology Steam Turbine 2 Vapor Power Cycle 4 5 Steam Turbine A steam turbine is prime mover

More information

AC MOTOR TYPES. DESCRIBE how torque is produced in a single-phase AC motor. EXPLAIN why an AC synchronous motor does not have starting torque.

AC MOTOR TYPES. DESCRIBE how torque is produced in a single-phase AC motor. EXPLAIN why an AC synchronous motor does not have starting torque. Various types of AC motors are used for specific applications. By matching the type of motor to the appropriate application, increased equipment performance can be obtained. EO 1.5 EO 1.6 EO 1.7 EO 1.8

More information

Electro hydraulic actuating system is a complete modular unit with a wide range of actuator cylinders (type ASM) having a

Electro hydraulic actuating system is a complete modular unit with a wide range of actuator cylinders (type ASM) having a Electro Hydraulic Actuating System 7 Electro hydraulic actuating system is a complete modular unit with a wide range of actuator cylinders (type ASM) having a force of about 100 tonnes and large stroke.

More information

Electrical Theory. Generator Theory. PJM State & Member Training Dept. PJM /22/2018

Electrical Theory. Generator Theory. PJM State & Member Training Dept. PJM /22/2018 Electrical Theory Generator Theory PJM State & Member Training Dept. PJM 2018 Objectives The student will be able to: Describe the process of electromagnetic induction Identify the major components of

More information

Unit 32 Three-Phase Alternators

Unit 32 Three-Phase Alternators Unit 32 Three-Phase Alternators Objectives: Discuss the operation of a three-phase alternator. Explain the effect of rotation speed on frequency. Explain the effect of field excitation on output voltage.

More information

THOMSON AIRWAYS LIMITED DISCREPANCY SHEET

THOMSON AIRWAYS LIMITED DISCREPANCY SHEET IPC REF FIG ITEM DESCRIPTION FROM 72.35.01 01 085/220 ROTATING FAIRINGS 72.31.11 01 280 LP BLADES (22 OFF) 73.11.07 01 645/725 MAIN FUEL INLET TUBE 29.11.03 02 100 HYD. SUPPLY,RIGID TUBE 29.11.03 02 200

More information

MINI PACK N/A N/A N/A N/A FA0995 N/A

MINI PACK N/A N/A N/A N/A FA0995 N/A MINI PACK ENGINE MODEL: PW150 BUILD SPEC: 885 TM SN: FA0995 TSN: 4,327.60 CSN: 4,194 TSO: CSO: TSHSI: CSHSI: N/A N/A N/A N/A RGB SN: FA0995 TSN: 4,327.60 CSN: 5,194 TSO: N/A CSO: N/A CONTENTS: - TMM Transport

More information

ROTATING MAGNETIC FIELD

ROTATING MAGNETIC FIELD Chapter 5 ROTATING MAGNETIC FIELD 1 A rotating magnetic field is the key to the operation of AC motors. The magnetic field of the stator is made to rotate electrically around and around in a circle. Stator

More information

Teepak Totally Enclosed Tube Ventilated High Voltage Induction Motors. A Regal Brand.

Teepak Totally Enclosed Tube Ventilated High Voltage Induction Motors. A Regal Brand. Teepak Totally Enclosed Tube Ventilated High Voltage Induction Motors A Regal Brand www.regalbeloit.com Specifications Range Poles Voltage : Upto 3000 KW : Upto 14 Pole : Upto 11000 Volt Frame : 450 1000

More information

Analysis and Evaluation of Applicability and Modification Effect of New Style Steam Seal for Steam Turbine

Analysis and Evaluation of Applicability and Modification Effect of New Style Steam Seal for Steam Turbine International Conference on Civil, Transportation and Environment (ICCTE 2016) Analysis and Evaluation of Applicability and Modification Effect of New Style Steam Seal for Steam Turbine Xuedong Wang1 a,

More information

Charging Systems. ATASA 5 th. ATASA 5 TH Study Guide Chapter 19 Pages Charging Systems 42 Points. Please Read The Summary

Charging Systems. ATASA 5 th. ATASA 5 TH Study Guide Chapter 19 Pages Charging Systems 42 Points. Please Read The Summary ATASA 5 TH Study Guide Chapter 19 Pages 571 595 42 Points Please Read The Summary 1. The primary purpose of the charging system is to the battery with a constant and relatively low charge after it has

More information

M50 L50 Series Multistage Regenerative Turbine Pumps

M50 L50 Series Multistage Regenerative Turbine Pumps Page M- MTH PUMPS M L Series Multistage Regenerative Turbine Pumps Capacities to 4 GPM Heads to Feet Single or Multi-stage Units (up to stages) Vertical Close Coupled Horizontal Close Coupled Horizontal

More information

Carli Suspension Front Instructions

Carli Suspension Front Instructions Carli Suspension Front Instructions 94-08 DODGE 2500-3500 4X4 SUSPENSION SYSTEM Note: Prior to installation, carefully inspect the vehicle=s steering and drive train components. Be sure to check ball joints,

More information

GUADALUPE POWER PARTNERS, LP Section MAINTENANCE GT1 CI WORK SCOPE

GUADALUPE POWER PARTNERS, LP Section MAINTENANCE GT1 CI WORK SCOPE Outage; Combustion Inspection on Gas Turbine #1 serial number 297365 Start Date; March 15, 2009 Completion Date; March 21, 2009 Test Fire and Tune Date; March 20, 2009 Work Scope Summary o Combustion Inspection

More information

CHAPTER 6 DESIGN AND DEVELOPMENT OF DOUBLE WINDING INDUCTION GENERATOR

CHAPTER 6 DESIGN AND DEVELOPMENT OF DOUBLE WINDING INDUCTION GENERATOR 100 CHAPTER 6 DESIGN AND DEVELOPMENT OF DOUBLE WINDING INDUCTION GENERATOR 6.1 INTRODUCTION Conventional energy resources are not sufficient to meet the increasing electrical power demand. The usages of

More information

Excitation System Of Alternator

Excitation System Of Alternator Excitation System Of Alternator 1. Mithul S. There 2. Pragati S. Chawardol 3. Deepali R. Badre Assistant professor in Balaji Polytechnic, Wani (M.S.) ABSTRACT The brush gear and slip-ring have become such

More information

Inside the Generator

Inside the Generator NHA Hydraulic Power Committee Fall Retreat & NWHA Technical Conference October 3, 2018 Walla Walla, WA Inside the Generator W. Howard Moudy Director of Operations National Electric Coil The Classic Simplified

More information

ATMOSPHERIC RELIEF VALVE

ATMOSPHERIC RELIEF VALVE IOM-ARV-0814 ATMOSPHERIC RELIEF VALVE INSTALLATION, OPERATION AND MAINTENANCE MANUAL GRAHAM CORPORATION Corporate and Sales Headquarters: 20 Florence Avenue, Batavia, New York 14020 Tel.: 585-343-2216

More information

SSC-JE STAFF SELECTION COMMISSION ELECTRICAL ENGINEERING STUDY MATERIAL ELECTRICAL MACHINES

SSC-JE STAFF SELECTION COMMISSION ELECTRICAL ENGINEERING STUDY MATERIAL ELECTRICAL MACHINES 1 SSC-JE STAFF SELECTION COMMISSION ELECTRICAL ENGINEERING STUDY MATERIAL 28-B/7, Jia Sarai, Near IIT, Hauz Khas, New Delhi-110016. Ph. 011-26514888. www.engineersinstitute.com 2 CONTENT 1. : DC MACHINE,

More information

RNRG WHITE PAPER Early Detection of High Speed Bearing Failures

RNRG WHITE PAPER Early Detection of High Speed Bearing Failures BACKGROUND RNRG worked with a large wind turbine owner in North America to demonstrate that the TurbinePhD condition monitoring system can detect faults early and reduce maintenance costs. An evaluation

More information

Turbogenerators. With Top Performance for Steam and Gas Applications. Specifically tailored 4-pole Synchronous Turbogenerators

Turbogenerators. With Top Performance for Steam and Gas Applications. Specifically tailored 4-pole Synchronous Turbogenerators Turbogenerators With Top Performance for Steam and Gas Applications Specifically tailored 4-pole Synchronous Turbogenerators siemens.com / automation 2 Top Performance Turbogenerators for Steam and Gas

More information

Inventory # Lot # Lead

Inventory # Lot # Lead 2125800 5 Transformer Cooler 2125801 6 Valves 2125802 7 Globe Valve 2125803 8 Check Valve 2125804 9 Flow Control Valve 2125805 10 Tricentic Valves 2125806 11 Gate Valve 2125807 12 Gate Valves 2125808 13

More information

ELIMINATION OF REPETITIVE THRUST BEARING FAILURES ON A PROCESS AIR COMPRESSOR

ELIMINATION OF REPETITIVE THRUST BEARING FAILURES ON A PROCESS AIR COMPRESSOR ELIMINATION OF REPETITIVE THRUST BEARING FAILURES ON A PROCESS AIR COMPRESSOR BY : M. M. PITKAR RELIANCE INDUSTRIES LIMITED, PATALGANGA INDIA THE TEXAS A & M UNIVERSITY SYSTEM Slide No.: 1 of 24. BRIEF

More information

Electrical Systems - Course 135 COMPOSITE ELECTRICAL PROTECTIVE SCHEMES: PART II

Electrical Systems - Course 135 COMPOSITE ELECTRICAL PROTECTIVE SCHEMES: PART II 135 05-1 Electrical Systems - Course 135 COMPOSITE ELECTRICAL PROTECTIVE SCHEMES: PART II TURBINE-GENERATOR: rhipping AND ALARM CIRCUITS i.o' I titrodljction Following on from Lessons 135.03-1 and 135.04-1,

More information

Starting of Induction Motors

Starting of Induction Motors 1- Star Delta Starter The method achieved low starting current by first connecting the stator winding in star configuration, and then after the motor reaches a certain speed, throw switch changes the winding

More information

For Sale: Used Steam Turbine Generator Sets. Offer Ref. STG MW Steam Turbine Genset Condensing-Extraction type

For Sale: Used Steam Turbine Generator Sets. Offer Ref. STG MW Steam Turbine Genset Condensing-Extraction type Sonnenberger Str.16 Tel. +49 (0) 611-701888 www.lohrmann.com 65193 Wiesbaden - Germany Fax +49 (0) 611-701895 info@lohrmann.com For Sale: Used Steam Turbine Generator Sets Offer Ref. STG - 25.02 10 MW

More information

Turbine & Generator Rotor Welding to Solve Reliability and Performance Issues. Tom Smith President T and A Consultants April 16-17, 2013

Turbine & Generator Rotor Welding to Solve Reliability and Performance Issues. Tom Smith President T and A Consultants April 16-17, 2013 Turbine & Generator Rotor Welding to Solve Reliability and Performance Issues Tom Smith President T and A Consultants April 16-17, 2013 Rotor Welding History Rotor welding was developed in the U.S. in

More information

R6GD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, Three Phase, Packaged Gas/ Electric Units with R-410A 3-5 Ton Units WARRANTY

R6GD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, Three Phase, Packaged Gas/ Electric Units with R-410A 3-5 Ton Units WARRANTY TECHNICAL SPECIFICATIONS R6GD Series 13 SEER, Three Phase, Packaged Gas/ Electric Units with R-410A 3-5 Ton Units The R6GD Series packaged gas/electrics are high efficiency self contained cooling units

More information

Contents 1) Vibration situation for CGC Large Steam Turbine 2) Root cause analysis and evaluation method 3) Countermeasure with result

Contents 1) Vibration situation for CGC Large Steam Turbine 2) Root cause analysis and evaluation method 3) Countermeasure with result Preface A Large Steam Turbine had been in operation for several years and this turbine experienced the wear damage of governor linkage. Then, measured the vibration velocity profile on Governor side pedestal

More information

Guideline No.: E-04(201610) E-04 GENERATORS. Issued date: October 28,2016. China Classification Society

Guideline No.: E-04(201610) E-04 GENERATORS. Issued date: October 28,2016. China Classification Society Guideline No.: E-04(201610) E-04 GENERATORS Issued date: October 28,2016 China Classification Society Foreword: This Guideline is a part of CCS Rules, which contains technical requirements, inspection

More information

DewEze Clutch Pump Kit

DewEze Clutch Pump Kit DewEze Clutch Pump Kit 700538 Dodge 6.7L, 2011+, P415 12, 17 GPM Pump INSTALLATION INSTRUCTIONS Record Pump Model No. and Serial No. for future reference. 1. The installation of this kit requires trained

More information

Electrical Machine Service. Overhaul, Conditioning, On-Site Service and Diagnostics. Excellent Technology, Efficiency and Quality

Electrical Machine Service. Overhaul, Conditioning, On-Site Service and Diagnostics. Excellent Technology, Efficiency and Quality World Class Power Solutions Excellent Technology, Efficiency and Quality Electrical Machine Service Overhaul, Conditioning, On-Site Service and Diagnostics 2 3 Your partner for Electrical Machine Service

More information

Rolls-Royce Corporation 501-D22 COMMERCIAL ENGINE BULLETIN (CEB) Technical Publications Index

Rolls-Royce Corporation 501-D22 COMMERCIAL ENGINE BULLETIN (CEB) Technical Publications Index Corporation 501-D22 COMMERCIAL ENGINE BULLETIN (CEB) Technical Publications Index May 1. 2018 72-- ENGINE 72--1001 Engine -- Reduction Gear Prop Recommended No Later Than 11--01--66 No. 2, 11--15--68 Brake

More information

Feedwater Reg Valve Internal Erosion OR17 Fall 2015

Feedwater Reg Valve Internal Erosion OR17 Fall 2015 Seabrook Station Feedwater Reg Valve Internal Erosion OR17 Fall 2015 Jim Johnson Feedwater System Engineer 2 Seabrook FRV Setup Seabrook Station FRV History Started Commercial Operation in 1990 Feedwater

More information

10 kw, 15φ Axial flux pancake generator for 2-blade Wind Turbine

10 kw, 15φ Axial flux pancake generator for 2-blade Wind Turbine 10 kw, 15φ Axial flux pancake generator for 2-blade Wind Turbine Abstract A 10kW permanent magnet electric generator has been built and tested for use with a high tsr 5m blade diameter wind turbine. The

More information

ECEg439:-Electrical Machine II

ECEg439:-Electrical Machine II ECEg439:-Electrical Machine II 2.2 Main Structural Elements of DC Machine Construction of DC Machines A DC machine consists of two main parts 1. Stationary Part (Stator):-It is designed mainly for producing

More information

World s highest capacity steam turbosets for the lignite-fired Lippendorf power station

World s highest capacity steam turbosets for the lignite-fired Lippendorf power station World s highest capacity steam turbosets for the lignite-fired Lippendorf power station The two 933-MW steam turbosets being supplied by ABB to the Lippendorf power plant in Germany are the highest capacity,

More information

Siemens Cold Climate Strategy

Siemens Cold Climate Strategy Siemens Cold Climate Strategy Improving output in harsh conditions Unrestricted Siemens Wind Power, 2015 All rights reserved. Agenda Siemens Wind Power Blade De-Icing Experience Next Steps & Challenges

More information

Synchronous Generators I. Spring 2013

Synchronous Generators I. Spring 2013 Synchronous Generators I Spring 2013 Construction of synchronous machines In a synchronous generator, a DC current is applied to the rotor winding producing a rotor magnetic field. The rotor is then turned

More information

ACCESSORY KIT INSTALLATION INSTRUCTIONS

ACCESSORY KIT INSTALLATION INSTRUCTIONS ACCESSORY KIT INSTALLATION INSTRUCTIONS Low Ambient Accessory For Air Cooled Split-System Air Conditioners (H5CE180/240, HEHB180/240 and J15/20H5CE odels Only) 350160-UAI-B-0709 GENERAL Standard split-system

More information

OTHER ELECTRICAL MEASURING DEVICES

OTHER ELECTRICAL MEASURING DEVICES Other measuring devices are used to aid operators in determining the electric plant conditions at a facility, such as the ampere-hour meter, power factor meter, ground detector, and synchroscope. EO 1.2

More information

Beyond 60% - Pioneering H-class Efficiency with World Class Flexibility

Beyond 60% - Pioneering H-class Efficiency with World Class Flexibility SCC5-8000H / Irsching 4 Beyond 60% - Pioneering H-class Efficiency with World Class Flexibility Irsching General Manager for GT Power Plant Solutions Europe, Africa, Asia and Australia Siemens AG 2011.

More information

Generator Services. WGGS Capabilities Presentation

Generator Services. WGGS Capabilities Presentation WGGS Capabilities Presentation Our Location LOCATION: New Farmington, Wood Four Mexico, Corners, Group USA New Generator Mexico Services, Inc. Turbo Power Hydro Power Petroleum Steel Paper Our Focus Turbo

More information

GE Power & Water Power Generation Services

GE Power & Water Power Generation Services GE Power & Water Power Generation Services Generator Lifecycle Services Generating powerful solutions. Breathing new life into your aging generator. Reduce Maintenance Costs Increase Reliability Increase

More information

Industrial Steam Turbines. The comprehensive product range from 2 to 250 megawatts. Answers for energy.

Industrial Steam Turbines. The comprehensive product range from 2 to 250 megawatts. Answers for energy. Industrial Steam Turbines The comprehensive product range from 2 to 250 megawatts Answers for energy. A Full Range of World-class Industrial Steam Turbines Whatever your need for a prime mover, Siemens

More information

Blade Repair Challenges

Blade Repair Challenges Blade Repair Challenges Wind Energy Operations & Maintenance Summit Wind Energy Update April 25-27, 2012 Dallas, TX Presented by Gary Kanaby Quality Engineered Value 2 Presenta(on Outline Neglecting inspection

More information

REVELSTOKE - 1 YEAR DOWN. Applied to Equipment Instruction Number R Class-Group Generate Date: 11 March 2004

REVELSTOKE - 1 YEAR DOWN. Applied to Equipment Instruction Number R Class-Group Generate Date: 11 March 2004 Page 1 of 7 Planned Maint. Type Turbo file - Job Group 1Y-DOWN Lead Trade Applied to Equipment Instruction Number R Class-Group Generate Date: 11 March 2004 Isolation Zone Supersedes References J:\PS\mep\Maintenance

More information

INDUSTRIAL HEATING BLANKETS

INDUSTRIAL HEATING BLANKETS Insulated Industrial Heating Blankets Industrial heating blankets are able to heat up material including composite, carbon, epoxy prepreg and ensure a safe and uniform temperature distribution on the surface

More information

Centro América Application of EMI Diagnostics to Diesel Generators

Centro América Application of EMI Diagnostics to Diesel Generators Application of EMI Diagnostics to Diesel Generators CATEGORIAS *Experiencias con características de lotes de combustibles * Control de eficiencia de motores * Aliados clave para operadores de motores *

More information

Project Report on Engineering Services for the Wind Turbine Project at the Cuyahoga County Fair

Project Report on Engineering Services for the Wind Turbine Project at the Cuyahoga County Fair Lorry Wagner, Ph.D. 216-361-4250 x101 lorry@phillipselectric.com 4126 St. Clair Ave Cleveland, Ohio 44103 Project Report on Engineering Services for the Wind Turbine Project at the Cuyahoga County Fair

More information

PORTISHEAD B POWER STATION

PORTISHEAD B POWER STATION PORTISHEAD B POWER STATION Portishead B Statistics: Main Building (General) Overall length: 704 ft. Overall width: 186 ft. Height above ground: 138 ft. (boiler house) Height above ground: 80 ft. (turbine

More information

LP Spare parts list. Duplex roller. s/n BGF Engine: Hatz 1D Construction Tools EOOD No

LP Spare parts list. Duplex roller. s/n BGF Engine: Hatz 1D Construction Tools EOOD No LP 7505 Spare parts list Duplex roller s/n BGF000001- Engine: Hatz 1D 50 2015 Construction Tools EOOD No. 9800174901 2015-12 F1700C Spare parts list General information This spare parts list applies to

More information

2017 Kansas Science Olympiad

2017 Kansas Science Olympiad 2017 Kansas Science Olympiad WRIGHT STUFF Division B Charles Le Event Supervisor cmle@cox.net MONOPLANE Photo: http://scienceguyorg.blogspot.com/2013/04/ultimate-indoor-free-flight-model-plane.html CONSTRUCTION

More information

Guideline No.: E-04(201510) E-04 GENERATORS. Issued date: October 20,2015. China Classification Society

Guideline No.: E-04(201510) E-04 GENERATORS. Issued date: October 20,2015. China Classification Society Guideline No.: E-04(201510) E-04 GENERATORS Issued date: October 20,2015 China Classification Society Foreword: This Guideline is a part of CCS Rules, which contains technical requirements, inspection

More information

INSTRUCTION MANUAL ANGLE GRINDER PT W

INSTRUCTION MANUAL ANGLE GRINDER PT W INSTRUCTION MANUAL ANGLE GRINDER PT50360 4½ INCHES 120V 60Hz 600W 5A 12,000 rpm C US Note : Before operating this tool, read this manual and follow all safety rules and operating instructions. This electric

More information

Synchronous Generators I. EE 340 Spring 2011

Synchronous Generators I. EE 340 Spring 2011 Synchronous Generators I EE 340 Spring 2011 Construction of synchronous machines In a synchronous generator, a DC current is applied to the rotor winding producing a rotor magnetic field. The rotor is

More information

Impact of Slot Discharges and Vibration Sparking on Stator Winding Life in Large Generators

Impact of Slot Discharges and Vibration Sparking on Stator Winding Life in Large Generators F E A T U R E A R T I C L E Impact of Slot Discharges and Vibration Sparking on Stator Winding Life in Large Generators Key Words: slot discharge, vibration sparking, spark erosion, stator winding Introduction

More information

Guardian Packing Rings. Vortex Shedder Seals. Turbine Components. Custom Installation. Reverse Engineering

Guardian Packing Rings. Vortex Shedder Seals. Turbine Components. Custom Installation. Reverse Engineering Guardian Packing Rings Vortex Shedder Seals Turbine Components Custom Installation Reverse Engineering ADVANCED SEALING SYSTEM by Turbo Parts, LLC. Guardian Packing Rings Prevent Seal Damage While Maintaining

More information

SGT-2000E gas turbine series

SGT-2000E gas turbine series SGT-2000E gas turbine series Value for customers This PDF offers an advanced interactive experience. For the best viewing experience, please use Acrobat Reader X or higher. SGT-2000E series: Reliable,

More information

NITIN CORPORATION 402, 4 th Floor, Bezzola Commercial Complex, Sion Trombay Road, Chembur, Mumbai , India.

NITIN CORPORATION 402, 4 th Floor, Bezzola Commercial Complex, Sion Trombay Road, Chembur, Mumbai , India. NITIN CORPORATION 402, 4 th Floor, Bezzola Commercial Complex, Sion Trombay Road, Chembur, Mumbai 400071, India. WEB : www.corponit.com E MAIL : nitincorporation@yahoo.com enquiry@corponit.com PH (O) :

More information

Annex I Tested by (name + signature)...: Approved by (name + signature)...: Date of issue... : 22/11/2012. TUV RHEINLAND ITALIA S.r.l.

Annex I Tested by (name + signature)...: Approved by (name + signature)...: Date of issue... : 22/11/2012. TUV RHEINLAND ITALIA S.r.l. TEST REORT Rotating electrical machines art 5: Degrees of protection provided by the integral design of rotating electrical machines (I code) Classification Report Reference No....: 28105442 002 Annex

More information

STANDARD PROCEDURE FOR STORAGE OF ACCO SPEEDWAY & WORK-RATED ELECTRIC WIRE ROPE HOISTS AS RECOMMENDED BY ACCO MATERIAL HANDLING SOLUTIONS

STANDARD PROCEDURE FOR STORAGE OF ACCO SPEEDWAY & WORK-RATED ELECTRIC WIRE ROPE HOISTS AS RECOMMENDED BY ACCO MATERIAL HANDLING SOLUTIONS STANDARD PROCEDURE FOR STORAGE OF ACCO SPEEDWAY & WORK-RATED ELECTRIC WIRE ROPE HOISTS AS RECOMMENDED BY ACCO MATERIAL HANDLING SOLUTIONS Revision: August, 2014 CONTENTS 1.0 Scope 2.0 Short term storage

More information

PRODUCTS. Multi-Stage Steam Turbines. Proven reliability and efficiency

PRODUCTS. Multi-Stage Steam Turbines. Proven reliability and efficiency PRODUCTS Multi-Stage Steam Turbines Proven reliability and efficiency Introduction Proven Reliability and Efficiency Dependable, versatile turbomachinery is essential for today s refinery, chemical process,

More information

ACTIVE STATOR - A MORE EFFICIENT DRIVE TRAIN CONCEPT FOR A WIND TURBINE. Dr. Makhlouf Benatmane - Director Business Development

ACTIVE STATOR - A MORE EFFICIENT DRIVE TRAIN CONCEPT FOR A WIND TURBINE. Dr. Makhlouf Benatmane - Director Business Development ACTIVE STATOR - A MORE EFFICIENT DRIVE TRAIN Dr. Makhlouf Benatmane - Director Business Development The Renewables power train Introduction The active Stator TM Concept DC - AC Architecture Conclusion

More information

Diesel Power Generating Plants. Introduction

Diesel Power Generating Plants. Introduction Diesel Power Generating Plants Introduction Steve Mackay Dean of Engineering Worked for 30 years in Industrial Automation 30 years experience in mining, oil and gas, electrical and manufacturing industries

More information

Inverter PAC. Introduction. March 2009

Inverter PAC. Introduction. March 2009 Inverter PAC Introduction March 2009 Inverter driven PAC Contents 1. Line up 2. Model name 3. Concept and the technical feature 1. Compactness of the outdoor unit 2. weight-saving outdoor unit 3. Improved

More information

LP Portable Wind Power Generation Kit

LP Portable Wind Power Generation Kit LP-2025 Portable Wind Power Generation Kit 1. Introduction: The wind generator, electrical storage devices, wind-and-solar complement charge controller and output system are all in the suitcase. The blade

More information

LIST OF PUBLISHED STANDARDS

LIST OF PUBLISHED STANDARDS Report : 07--0 Page o : Of 6 LST OF PUBLSHED STDRDS Total Count: 7 umber SS umber nt pproved mendment SBS/TC 06 SS 954:0.0 Metal-arc welding equipment (non-automatic, 0-0-8 single-operator, transformer

More information

Research and Reviews: Journal of Engineering and Technology

Research and Reviews: Journal of Engineering and Technology Research and Reviews: Journal of Engineering and Technology Brushless Excitation System of Turbo Generator Komala Koila* Department of Electrical and Electronics, Khammam Institute of Technology and Sciences,

More information

STEAM TURBINE CALCULATION SHEET Page : 1

STEAM TURBINE CALCULATION SHEET Page : 1 STEAM TURBINE CALCULATION SHEET Page : 1 STEAM CONSUMPTION 1 EXTRACTION TURBINE 2 Turbine type CURTIS+REACTION 3 Control stage : Curtis 4 CONDENSING TURBINE 5 REQUIRED CONDITION 6 Normal Rated 7 Steam

More information

STEAM TURBINE CALCULATION SHEET Page : 1

STEAM TURBINE CALCULATION SHEET Page : 1 STEAM TURBINE CALCULATION SHEET Page : 1 STEAM CONSUMPTION 1 ADMISSION TURBINE 2 Turbine type CURTIS+REACTION 3 Control stage : Curtis 4 CONDENSING TURBINE 5 REQUIRED CONDITION 6 Impulse Reaction 7 P kw

More information

UNIVERSAL TYPE EXPANSION JOINT-UN TIED (MUN)

UNIVERSAL TYPE EXPANSION JOINT-UN TIED (MUN) SINGLE TYPE EXPANSION JOINT-UN TIED (MSN) The simplest form of expansion joint, of single bellows construction, designed to absorb all of the movements of the pipe section in which it is installed. According

More information