1 Page 1 of 6 Nuclear Generation Limited Company Specification Generic Emergency Handbook (Nuclear Generation) Section 16 Emergency Equipment Originated by: John Babb Emergency Planning Group Date: January 2013 Reviewed by: EP Peer Group Date: January 2013 Approved by: John Skegg Head of Emergency Planning Group Date: January 2013 Revision Amendment Impact level Date 003 Document converted to current EDF NG template Changes include company name and organisational updates Minor January Published in the United Kingdom by EDF Energy Nuclear Generation Ltd. All rights reserved. No part of this publication may be reproduced or transmitted in any form or by any means, including photocopying and recording, without the written permission of the copyright holder, EDF Energy Nuclear Generation Ltd, application for which should be addressed to the publisher. Such written permission must also be obtained before any part of this publication is stored in a retrieval system of any nature. Requests for copies of this document should be referred to Barnwood Document Centre, Location 12, EDF Energy Nuclear Generation Ltd, Barnett Way, Barnwood, Gloucester GL4 3RS (Tel: ). The electronic copy is the current issue and printing renders this document uncontrolled. Controlled copy-holders will continue to receive updates as usual. LIMITATION OF LIABILITY Whilst EDF Energy Nuclear Generation Ltd believes that the information given in this document is correct at the date of publication it does not guarantee that this is so, nor that the information is suitable for any particular purpose. Users must therefore satisfy themselves as to the suitability of the information for the purpose for which they require it and must make all checks they deem necessary to verify the accuracy thereof. EDF Energy Nuclear Generation Ltd shall not be liable for any loss or damage (except for death or personal injury caused by negligence) arising from any use to which the information is put. Parent Document Ref: BEG/ICP/QUA/DM/003 Template Ref: BEG/FORM/QUA/002 Rev 022
2 Page 2 of 6 Contents 16.1 Emergency Control Centre And Alternative Emergency Control Centre Central Control Room / Main Control Room...Error! Bookmark not defined Muster Points On-Site Survey Vehicle Equipment List: Off-Site Survey Vehicle Access Control Point Incident Response Team Standby Emergency Response Team First Aid And Medical Decontamination Centres Gatehouse Breathing Apparatus FLASK/NAIR Miscellaneous... 6
3 Page 3 of Emergency Control Centre And Alternative Emergency Control Centre 16.2 Central Control Room / Main Control Room 16.3 Muster Points
4 Page 4 of On-Site Survey Vehicle Dedicated electric enclosed vehicle or near equivalent UHF radio Air sampler (R&M EASL 50 12v) Air sample volume meter (see Off-Site Survey list for details) Timer NE 710 BP4 castle (set of 10% 4 using BNL C1-36 Maypack source) Mini Instruments 6-90 scaler (with modification to give fsd) 100 : 1 attenuator Castle Maypack jig Castle GFA air sample counting tray Maypack air sample adaptor Normal GFA air sample head Dose rate meter type RO2 Dose rate meter type RM5/BP4 Dose meter type Maypacks in sealed containers BNL C1-36 check-source Maypack CO2 detector Respirators with charcoal filters Waterproof nylon coveralls with hoods PVC overshoes Rubber gloves Disposable gloves Safety helmets Pens 50 x forms EP/10.2/2 25 x preliminary sample forms EP/10.2/1 On-site Survey sample point map Torch and spare batteries 10 Potassium Iodate tablets and water Assorted polythene bags Installed BA bottle trolley system 2 x escape BA sets
5 Page 5 of Equipment List: Off-Site Survey Vehicle Suitable vehicle with amber beacon and internal fluorescent lights Air Sampler (R & M EASL 50, 12v) Air Sample Volume meter (Parkinson Cowen Gasmeter U6 synthetic diaphragm without CLWs m scale) (delete m3 ) and decimal point from scale to give litres) NE 710 BP4 Castle (set to 10% Eff using BNL Cl-36 Maypack) with PB4/4 probe Mini Instruments Type 6 9 (modified 6-90) scaler (set for operation with NE Technology probe BP4/4). 100 : 1 Attenuator Castle Maypack Jig Maypack air sample adaptor NE PDR1 dose rate meter NE PDR2 dose rate meter DRCD 20 Maypacks (Centrally assembled) BNL C1 36 Check-source Maypack to give 1,000 cps (all sites and vehicles to have BNL sources giving the same count rate). 2 x Waterproof Nylon coveralls (06/06/09 series) 10 prs PVC overshoes 100 prs Disposable gloves Large self-seal polythene bags 6 x pens 50 Forms 1 : 2500 Map showing Off-site Sampling Points/Sample Point Schedule and descriptions 1 Box Potassium Iodate tablets 1 Bottle Water 1 10 min Timer 1 Radio 1 Fire Extinguisher 1 First Aid Kit When supporting other sites the following additional equipment will be carried 1. Reception Centre kit as listed in EP/10/9/2 2. District Survey kit as listed in EP/8.2.6
6 Page 6 of Access Control Point 16.7 Incident Response Team 16.8 Standby Emergency Response Team 16.9 First Aid And Medical Decontamination Centres Gatehouse Breathing Apparatus FLASK/NAIR Miscellaneous
APPLICATION GUIDE FOR: CAMSHAFT DRIVE CHAIN WEAR INDICATOR
BRITISH MADE APPLICATION GUIDE FOR: CAMSHAFT DRIVE CHAIN WEAR INDICATOR 16239 This document is part of the product, keep it for the life of the product passing it on to any subsequent holder of the product.
More informationTECHNICAL SPECIFICATION
TECHNICAL SPECIFICATION TS96 AR ISSUE 5 Issued 2014-05 Amendment Record NOTE: The issue status of this document remains unchanged as there have been no changes to the technical content. SAE INDUSTRY TECHNOLOGIES
More information04979, 04980, 04981, 04982, 04983, 04984, 39054, 39055, 39056, 39057, 39225, 81459,
Hydraulic Bottle Jacks 04979, 04980, 04981, 04982, 04983, 04984, 39054, 39055, 39056, 39057, 39225, 81459, 82132. These instructions accompanying the product are the original instructions. This document
More informationA MODEL SYLLABUS FOR THE TRAINING OF TECHNICIANS INVOLVED IN THE EXAMINATION, TESTING, MAINTENANCE AND REPAIR OF PETROLEUM ROAD TANKERS
A MODEL SYLLABUS FOR THE TRAINING OF TECHNICIANS INVOLVED IN THE EXAMINATION, TESTING, MAINTENANCE AND REPAIR OF PETROLEUM ROAD TANKERS A MODEL SYLLABUS FOR THE TRAINING OF TECHNICIANS INVOLVED IN THE
More informationLarge Display ph Pens , , Instruction Manual
Large Display ph Pens 850050, 850051, 850052 Instruction Manual Large Display ph Pens - 850050, 850051, 850052 Copyright 2015 by Sper Scientific ALL RIGHTS RESERVED. Printed in the USA The contents of
More information2 TONNE TROLLEY JACK
2 TONNE TROLLEY JACK 61829 IMPORTANT: Please read these instructions carefully to ensure the safe and effective use of this product and save these instructions for future reference. This manual has been
More informationCONTACTS RELAY TESTER 66249
RELAY TESTER 66249 These instructions accompanying the product are the original instructions. This document is part of the product, keep it for the life of the product passing it on to any subsequent holder
More informationDo-It-Yourself Battery Pack
Do-It-Yourself Battery Pack 1 Page D I S C L A I M E R O F L I A B I L I T Y A N D W A R R A N T Y This publication describes the author s opinions regarding the subject matter herein. The author and publisher
More informationAn investigation of mortality and cancer incidence in United Kingdom oil refinery workers,
An investigation of mortality and cancer incidence in United Kingdom oil refinery workers, 1951 2011 AN INVESTIGATION OF MORTALITY AND CANCER INCIDENCE IN UNITED KINGDOM OIL REFINERY WORKERS, 1951 2011
More informationCONTACTS EGR VALVE TESTER 66248
EGR VALVE TESTER 66248 These instructions accompanying the product are the original instructions. This document is part of the product, keep it for the life of the product passing it on to any subsequent
More informationControl, Safe Use and Operation of Road-Rail Plant
Control, Safe Use and Operation of Page 1 of 13 Part A Synopsis A Standard detailing the requirements for the control, safe use and operation of road-rail plant in the railway environment. Approval and
More informationTESTER SET SOCKET & VOLTAGE
SOCKET & VOLTAGE TESTER SET 82384 These instructions accompanying the product are the original instructions. This document is part of the product, keep it for the life of the product passing it on to any
More information/6 March 31, Supersedes Technical Service Bulletin Group 27 number dated October 31, 2016 for reasons listed below.
27 Vibrations felt at 1000 rpm and 3000 rpm 27 17 29 2036392/6 March 31, 2017. Supersedes Technical Service Bulletin Group 27 number 16-27 dated October 31, 2016 for reasons listed below. Model(s) Year
More information3 TONNE TROLLEY JACK
3 TONNE TROLLEY JACK 16407 These instructions accompanying the product are the original instructions. This document is part of the product, keep it for the life of the product passing it on to any subsequent
More informationSOUTH AFRICAN NATIONAL STANDARD. Plug and socket-outlet systems for household and similar purposes for use in South Africa
ISBN 978-0-626-27016-2 SANS 164-1:2012 SOUTH AFRICAN NATIONAL STANDARD Plug and socket-outlet systems for household and similar purposes for use in South Africa Part 1: Conventional system, 16 A 250 V
More informationTIMING KIT APPLICATION GUIDE FOR: ENGINE
BRITISH MADE APPLICATION GUIDE FOR: ENGINE TIMING KIT 27021 This document is part of the product, keep it for the life of the product passing it on to any subsequent holder of the product. Read all information
More informationCommander SK. Technical Data Guide. Model sizes A to D and 2 to 6. AC variable speed drive for 3 phase induction motors
Technical Data Guide Commander SK sizes A to D and 2 to 6 AC variable speed drive for 3 phase induction motors Part Number: 0472-0002-09 Issue: 9 www.controltechniques.com Information The manufacturer
More informationIllustrated Parts List. Reproduction MODEL Not for. 10,000 Watt Standby Generator System
Illustrated Parts List MODEL 040375-00 040375-01 10,000 Watt Standby Generator System Manual Part No. 1756659 Revision A Rev. Date: 12/4/2013 Table Of Contents PRODUCT COMPONENTS PAGES Main Unit... 4
More informationADJUSTABLE ROTARY SCRAPER TOOL SCR USER S GUIDE
ADJUSTABLE ROTARY SCRAPER TOOL SCR-090-225 USER S GUIDE The information in this publication is provided for reference only. While every effort has been made to ensure the reliability and accuracy of the
More informationFlushing Instruction
Copyright WinGD. All rights reserved. By taking possession of the drawing, the recipient recognizes and honors these rights. Neither the who le nor any part of this drawing may be used in any way for construction,
More informationBULK FOOD TROLLEY MODEL BFT-150-E
BULK FOOD TROLLEY MODEL BFT-150-E Index: General Data 2 Owner s Responsibility 3 Authorised Vulcan Catering Equipment Branches and Dealers 3 Parts Ordering / Service Information 4 Prior to Installation
More informationAS/NZS 3131:2001 AS/NZS
AS/NZS 3131:2015 Australian/New Zealand Standard Approval and test specification Plugs and socket-outlets for stationary appliances Superseding AS/NZS 3131:2001 AS/NZS 3131:2015 AS/NZS 3131:2015 This joint
More informationLloyd s Register Type Approval System Test Specification Number GT04
Lloyd s Register Type Approval System Test Specification Number GT04 Gas Turbines Performance and test specifications for Gas Turbines to be used in Marine, Offshore and Industrial Applications 2004 Lloyd's
More informationLASER LEVEL KIT INTRODUCTION REVISION HISTORY UNDERSTANDING THIS MANUAL COPYRIGHT NOTICE CONTENTS...
,, Chandler's Ford,, Internet: drapertoolscom E-mail: sales@drapertoolscom Draper Tools Helpline for details of an agent in your local area These instructions accompanying the product are the original
More informationTrack Circuit Assister Configuration for Rail Vehicles
Track Circuit Assister Configuration for Rail Synopsis This Standard mandates where TCAs shall be fitted onto a vehicle and how they shall be set up. It also contains the requirements for testing a TCA.
More informationUser Guide Brake Test Tools Ø6 and Ø10
User Guide Brake Test Tools Ø6 and Ø10 Permaquip Ltd Brierley Industrial Park, Stanton Hill, Sutton-In-Ashfield, Nottinghamshire, NG17 3JZ Tel: +44 (0) 1623 513349 Fax: +44 (0) 1623 517742 E-mail: sales@permaquip.co.uk
More informationRECHARGE STATION OPERATION MANUAL. Version
RECHARGE STATION OPERATION MANUAL Version 1.0-0712 2014 by VirTra Inc. All Rights Reserved. VirTra, the VirTra logo are either registered trademarks or trademarks of VirTra in the United States and/or
More informationRAMMER BT1400, BT1600 PARTS BOOK
RAMMER www.bartellglobal.com Doc. # PB-B19027 Orig. Rel. 06/2016 Curr Rev. - 01 www.bartellglobal.com Bartell Morrison Inc. 375 Annagem Boulevard Mississauga, Ontario, Canada L5T 3A7 Tel: (647) 953-4100
More informationECE 44 Seat Cushions (O.K) User Manual
ECE 44 Seat Cushions (O.K) User Manual O.KC User Manual, ECE 44 Seat Cushions (O.K), Rev A Page 1 of 8 For information on Humanetics products, please visit our web site at www.humaneticsatd.com or contact:
More informationCOSASCO HYDRAULIC ACCESS FITTING User Manual
COSASCO HYDRAULIC ACCESS FITTING User Manual Rohrback Cosasco Systems, Inc. 11841 E. Smith Avenue Santa Fe Springs, CA 90670 Tel: (562) 949-0123 (800) 635-6898 Fax: (562) 949-3065 E-mail: sales@cosasco.com
More informationEVO TM 200 AND EVO TM 400 LCD DISPLAY INSTALLATION GUIDE
EVO TM 200 AND EVO TM 400 LCD DISPLAY INSTALLATION GUIDE The information in this publication is provided for reference only. While every effort has been made to ensure the reliability and accuracy of the
More informationNota Conductor s Chair
Assembly and Operation Instructions Nota Conductor s Chair CONTENTS Important User Information...........................2 General......................................2 Manufacturer.................................2
More informationINSTRUCTION MANUAL FOR THE THERMOCOUPLE ATTACHMENT UNIT (TAU)
INSTRUCTION MANUAL FOR THE THERMOCOUPLE ATTACHMENT UNIT (TAU) Model Number: 41756 (100 125Vac) 41757 (220 240Vac) Manufactured in the United Kingdom CONTENTS Chapter Page Specification 3 What the TAU does
More informationNational Grid UK Electricity Transmission plc. NATIONAL SAFETY INSTRUCTION and Guidance
National Grid UK Electricity Transmission plc NATIONAL SAFETY INSTRUCTION and Guidance NSI 31 APPROVAL / WITHDRAWAL OF PROCEDURES FOR NATIONAL GRID ELECTRICITY SAFETY RULES & SUPPORTING DOCUMENTATION Copyright
More informationRAMMER BT1000 PARTS BOOK
RAMMER BT1000 www.bartellglobal.com Doc. # PB-B19026 Orig. Rel. 06/2016 Curr Rev. - 01 www.bartellglobal.com Bartell Morrison Inc. 375 Annagem Boulevard Mississauga, Ontario, Canada L5T 3A7 Tel: (647)
More informationPERSONAL AIR SAMPLER & RADIATION ALARM
Big Bro REAL-TIME AIR FLOW METER COLLECTION OF ALPHA, BETA, GAMMA PARTICULATES FLOW RATE 3 LPM. BATTERY OPERATED RECHARGEABLE BATTERIES OK INTEGRATED EXPOSURE CAN DRAW AIR FROM ROOM OR BREATHING ZONE QUICK
More informationGENERAL INFORMATION. INSTRUCTIONS FOR 500A Lithium Jump Starter
INSTRUCTIONS FOR 500A Lithium Jump Starter Stock No.15067 Part No.LJS136 IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY TO ENSURE THE SAFE AND EFFECTIVE USE OF THIS PRODUCT. GENERAL INFORMATION These
More informationAS/NZS 3112:2004 AS/NZS
AS/NZS 3112:2011 Incorporating Amendment No. 1, 2, and 3 Australian/New Zealand Standard Approval and test specification Plugs and socket-outlets Superseding AS/NZS 3112:2004 AS/NZS 3112:2011 AS/NZS 3112:2011
More informationInstallation, Operating & Maintenance Instructions. HV angle valve with pneumatic actuator single acting with closing spring (NC)
Installation, Operating & Maintenance Instructions HV angle valve with pneumatic actuator single acting with closing spring (NC) Series 264 DN 10 50 mm (I. D. ⅜" 2") HV inline valve with pneumatic actuator
More informationUser Manual COSASCO HYDRAULIC ACCESS FITTING
COSASCO HYDRAULIC ACCESS FITTING User Manual Rohrback Cosasco Systems, Inc. 11841 E. Smith Avenue Santa Fe Springs, CA 90670 Tel: (562) 949-0123 (800) 635-6898 Fax: (562) 949-3065 E-mail: sales@cosasco.com
More informationOperator s Manual. Fairbanks FH Series by Fairbanks Scales, Inc. All rights reserved. . Revision 1 06/2017
Operator s Manual Fairbanks FH Series 2017 by Fairbanks Scales, Inc. All rights reserved 51393. Revision 1 06/2017 Amendment Record Fairbanks FH Series Operator s Manual Operator s Manual Document 51393
More informationOwner s Manual Supplement. Liquefied Petroleum Gas (LPG) Fuel System for 1998 GM Medium Duty Chassis (C-60/C-70) with 6.0L and 7.
Owner s Manual Supplement Liquefied Petroleum Gas (LPG) Fuel System for 1998 GM Medium Duty Chassis (C-60/C-70) with 6.0L and 7.0L V8 OWNERS MANUAL SUPPLEMENT Table of Contents Refueling Your Vehicle...1
More informationAS/NZS :2013. Wheelchairs AS/NZS :2013. Australian/New Zealand Standard
AS/NZS 3695.2:2013 Australian/New Zealand Standard Wheelchairs Part 2: Requirements and test methods for electrically powered wheelchairs (including mobility scooters) Superseding AS 3695 1992 AS/NZS 3695.2:2013
More informationFLEX CONNECTOR HEAT SHRINK SLEEVE INSTALLATION GUIDE
FLEX CONNECTOR HEAT SHRINK SLEEVE INSTALLATION GUIDE The information in this publication is provided for reference only. While every effort has been made to ensure the reliability and accuracy of the information
More informationHV angle valve with single acting pneumatic actuator and closing spring (NC)
Installation, Operating & Maintenance Instructions HV angle valve with single acting pneumatic actuator and closing spring (NC) Series 264 DN 100 160 mm (I. D. 4 6 ) This manual is valid for the following
More informationRelay Retrofit Program Cutting Tool Safety Guide
Relay Retrofit Program Cutting Tool Safety Guide Copyright This document and parts thereof must not be reproduced or copied without written permission from ABB, and the contents thereof must not be imparted
More informationBuck BioAire Model B520 Instruction Manual
A.P. BUCK, INC. Buck BioAire Model B520 Instruction Manual A.P. BUCK, INC. 7101 Presidents Drive Suite 110 Orlando, FL 32809 USA Tel 1-800-330-2825 407-851-8602 Fax 407-851-8910 apbuck@apbuck.com www.apbuck.com
More informationAustralian/New Zealand Standard
AS/NZS 4029.2:2000 AS/NZS 4029.2 Australian/New Zealand Standard Stationary batteries Lead-acid Part 2: Valve-regulated type (IEC 60896-2:1995, MOD) AS/NZS 4029.2:2000 This Joint Australian/New Zealand
More informationPARTS GUIDE Rev
HIGH CAPACITY OUTPUT STACKER (AS-1180C M8 STK) for the MACH 8 PARTS GUIDE Rev 09-17-14 This manual is intended solely for the use and information of Neopost USA, its designated agents, customers, and their
More informationInstallation, Operating & Maintenance Instructions. UHV gate valve with pneumatic actuator. Series 108 DN mm (I. D. 2½ 8 )
Installation, Operating & Maintenance Instructions UHV gate valve with pneumatic actuator Series 108 DN 63 200 mm (I. D. 2½ 8 ) This manual is valid for the following product ordering numbers: 108.. -.
More informationAS/NZS ISO :2013
ISO 7176-28:2012, IDT Australian/New Zealand Standard Wheelchairs Part 28: Requirements and test methods for stair-climbing devices AS/NZS ISO 7176.28:2013 This Joint Australian/New Zealand Standard was
More informationBuck BioSlide Model B1020 Instruction Manual
A.P. BUCK, INC. Buck BioSlide Model B1020 Instruction Manual 10-20LPM Constant Flow Bioaerosol Sampling Pump For Microscope Slides Page Quick Guide 3 Product Description and Features 4 A.P. BUCK, INC.
More informationDIAGNOSTIC TOOL BATTERY
BATTERY DIAGNOSTIC TOOL 81164 These instructions accompanying the product are the original instructions. This document is part of the product, keep it for the life of the product passing it on to any subsequent
More informationCBS 1035 CAPSTAN WINCH
CBS Products,(KT), Ltd, Pilings Road, Oakham, Rutland, LE15 6QF. UK Telephone: +44(0)1572 723665 Fax: +44(0)1572 756006 E-Mail: sales@cbsproducts.com Website: www.cbsproducts.com CBS 1035 CAPSTAN WINCH
More informationOutdoor Sensor Assembly (Veris) Installation Instructions
Description Novar s Outdoor Sensor Assembly (OSA) can be mounted on a building s roof to monitor outdoor temperatures, light levels, and/or humidity. The assembly comes with the following items: Outdoor
More informationLINK-BELT (Rough Terrain) LOAD CHART
For Use in CCO Written Examinations LINK-BELT (Rough Terrain) LOAD CHART TELESCOPIC BOOM CRANE SWING CAB (TLL) These charts have been adapted from the original manufacturer s charts for use in CCO Written
More informationInstallation, Operating & Maintenance Instructions. All-metal gate valve with compact or extended pneumatic actuator
Installation, Operating & Maintenance Instructions All-metal gate valve with compact or extended pneumatic actuator Series 48 DN 16 320 mm (I.D. ⅝" 12") This manual is valid for the following product ordering
More informationIllustrated Parts List MODEL. Reproduction Not for. 30,000 Watt Liquid Cooled
Illustrated Parts List MODEL 076080-00 30,000 Watt Liquid Cooled Generator System IPL No.1757520 Rev. - 9/17/2013 PRODUCT COMPONENTS Table Of Contents PAGES Main Unit... 4 Control Panel... 6 Enclosure...
More informationOWNER S HANDBOOK. Publication Part No. LRL
OWNER S HANDBOOK Publication Part No. LRL 10 02 50 501 Land Rover 2004 Introduction This handbook covers all versions of the Freelander petrol and diesel models and, together with the other books in the
More informationTeam Trike Assembly Instructions for 8142 Models
Team Trike Assembly Instructions for 84 Models paper! Tools required for adult assembly Printed on 00% recycled KETTLER International Inc 355 London Bridge Road Virginia Beach, Virginia 3453 USA www.kettlerusa.com
More informationTB-690 Conveyor/Stacker
TB-690 Conveyor/Stacker ASSEMBLY AND OPERATIONS MANUAL Revised: 1-9-09 RENA SYSTEMS INC. 136 Green Tree Road STE 140 Oaks, PA 19456-1069 Phone: (610) 650-9170 Fax: (610) 650-9171 E-Mail: support@renausa.com
More informationSPARE PARTS LIST. Spiromatic 90U 98878A01
SPARE PARTS LIST Spiromatic 90U 97A01 2006 Interspiro AB, Sweden. This publication contains or refers to proprietary information which is protected by copyright. All rights are reserved. Interspiro and
More informationContents. 1. Preface Change record Fuse Replacement...5. MPU fuses...5
Fuse Replacement Contents 1. Preface... 2. Change record...4. Fuse Replacement...5.1.2..4.5.6.7 ii MPU fuses...5 X1 fuses...6 X2 fuses...7 Y/Z fuses...8 Tool Rotation/Reciprocating knife fuses...9 Chiller
More informationDC Distribution Panel User Guide # S
DC Distribution Panel User Guide # S2-61256-100 68-11926-100 Standard Limited Hardware Warranty LIMITED WARRANTY. Equipment manufactured by CTI Products, Inc. is warranted to be free from defects in material
More informationINSTITUTE OF PETROLEUM TESTING OF VAPOUR CONTAINMENT ON PETROLEUM ROAD TANKERS
INSTITUTE OF PETROLEUM TESTING OF VAPOUR CONTAINMENT ON PETROLEUM ROAD TANKERS INSTITUTE OF PETROLEUM TESTING OF VAPOUR CONTAINMENT ON PETROLEUM ROAD TANKERS April 2001 Published by The Institute of Petroleum,
More informationECE 129 Seat Cushions User Manual
ECE 129 Seat Cushions User Manual ECE R129-9900 Seat Cushion User Manual, Rev A Page 1 of 7 For information on Humanetics products, please visit our web site at www.humaneticsatd.com or contact: Humanetics
More informationOnBoard Drum Major Podium
Assembly and Owner s Manual OnBoard Drum Major Podium CONTENTS CONTENTS................................................................................. 1 SAFETY...................................................................................
More informationGen 1 CNG Frame Mount FSM Parts Manual
Gen 1 CNG Frame Mount FSM Parts Manual Printed September 2, 2015 Rev D Preface FSM Parts Manual To reduce the chance of personal injury and/or property damage, the following instructions must be carefully
More informationRectangular Door L-VAT with pneumatic actuator double acting
Rectangular Door L-VAT with pneumatic actuator double acting This manual is valid for the products: 0 7 5 1 0 U A 2 4 0 0 0 1 4 character option code Size 10... 46 x 236 12... 50 x 336 Actuator 24... without
More informationPacking Procedure for 4 to 7.5 mm Liquid Samples. Sample Volumes of 46 to 450 µl Pub. No , Rev. C 0907
Packing Procedure for 4 to 7.5 mm Liquid Samples Sample Volumes of 46 to 450 µl Pub. No. 01-999336-00, Rev. C 0907 Pub. No. 01-999336-00, Rev. C 0907 Packing Procedure for 4 to 7.5 mm Liquid Samples Sample
More informationStructural Requirements For Drawgear And Buffers On Railway Vehicles
Structural Requirements For Drawgear And Buffers On Railway Vehicles Submitted by D. Boocock Nominated Responsible Manager Synopsis This standard prescribes the strength requirements for drawgear and buffers
More informationAustralian/New Zealand Standard
AS/NZS 3131 Australian/New Zealand Standard Approval and test specification Plugs and socket-outlets for stationary appliances This Joint Australian/New Zealand Standard was prepared by Joint Technical
More informationMaximum retail price list. For SIBCO range of bearing housings and accessories Bearing housings, sleeves, locknuts, lock washers and locating rings
Maximum retail price list For SIBCO range of bearing housings and accessories Bearing housings, sleeves, locknuts, lock washers and locating rings Effective from 1 st April, 2017 Engineered for optimized
More informationIllustrated Parts List MODEL. Reproduction Not for. 30,000 Watt Liquid Cooled Generator Systems
Illustrated Parts List MODEL 076080-00 30,000 Watt Liquid Cooled Generator Systems IPL No.1757520 Rev. A 3/23/2015 PRODUCT COMPONENTS Table Of Contents PAGES Main Unit... 4 Alternator... 6 Control Panel...
More informationEMERGENCY EGRESS LIGHTING POWER SUPPLY BATTERY
EMERGENCY EGRESS LIGHTING POWER SUPPLY BATTERY PART NO. COMPONENT MAINTENANCE MANUAL WITH ILLUSTRATED PARTS LIST V32890 Initial Issue: v. 1, 1994 33-51-93 Page T1 Proprietary Statement All illustrations
More informationDynojet Research, Inc. All Rights Reserved. Tire Temperature Sensor Installation Guide
1998-2006 Dynojet Research, Inc. All Rights Reserved. This manual is copyrighted by Dynojet Research, Inc., hereafter referred to as Dynojet, and all rights are reserved. This manual, as well as the software
More informationInstallation, Operating & Maintenance Instructions. HV gate valve with pneumatic actuator. Series 110 DN mm (I. D.
Installation, Operating & Maintenance Instructions HV gate valve with pneumatic actuator Series 110 DN 250 320 mm (I. D. 10" 12") This manual is valid for the following product ordering numbers: 11048-.
More informationPortableLadders > Ladder standards are changing > What does this mean for you? > What action do you need to take?
IMPORTANT INFORMATION SafetyGuidance PortableLadders > Ladder standards are changing > What does this mean for you? > What action do you need to take? The Ladder Association has played an important part
More information2009 FORMULA TWO TECHNICAL REGULATIONS
2009 FORMULA TWO TECHNICAL REGULATIONS ARTICLE 1 : DEFINITIONS 1.1 F2 1.2 Sporting Regulations 1.3 Event 1.4 Set-up Sheet 1.5 Test 1.6 F2 Technical Manual ARTICLE 2 : GENERAL PRINCIPLES 2.1 Validity 2.2
More informationUser Instruction Manual Oxford Classic Digital Weigh Scale. To avoid injury, read user manual prior to use.
User Instruction Manual Oxford Classic Digital To avoid injury, read user manual prior to use. Oxford English Contents 1. Introduction: About Your Scale... 3 2. Assembly and Commissioning Instructions...
More informationKIT CONTENTS REPORT ICBS. DATE : May 30, :57:58 AM USER ID : PAGE : 1 Report Sorted By : Component Item Description
USER ID : PAGE : 1 KIT ID DESCRIPTION KIT $132,938.13 001269 BAG - FLIGHT HELMET 3 EA $15.99 $47.97 000021 BAG - GARBAGE CAN LINER, PLASTIC, 30 GL, 39" X 33" 000022 BAG - SLEEPING, COLD WEATHER, 34" X
More informationMARYLAND STATE FIREMEN S ASSOCIATION Representing the Volunteer Fire, Rescue and Emergency Medical Services Personnel
MARYLAND STATE FIREMEN S ASSOCIATION Representing the Volunteer Fire, Rescue and Emergency Medical Services Personnel Standard Operating Procedure (SOP) SOP No: E002 Rev:- Title: ALS (MICU) Standards Effective
More informationMODEL 540 USER MANUAL INCORPORATING MODEL 530 TEMPERATURE CONTROLLER
MODEL 540 USER MANUAL INCORPORATING MODEL 530 TEMPERATURE CONTROLLER Signal Group Limited 12 Doman Road, Camberley Surrey, GU15 3DF England Tel: +44 (0) 1276 682841 Fax: +44 (0) 1276 691302 e-mail: instruments@signal-group.com
More information2010 FORMULA TWO TECHNICAL REGULATIONS
2010 FORMULA TWO TECHNICAL REGULATIONS ARTICLE 1 : DEFINITIONS 1.1 F2 1.2 Sporting Regulations 1.3 Event 1.4 Set-up Sheet 1.5 Test 1.6 F2 Technical Manual ARTICLE 2 : GENERAL PRINCIPLES 2.1 Validity 2.2
More informationService Circular 2005 Maintenance Service Circular
Subject: 2005 Model Year Volkswagen new Jetta Maintenance 2005 Maintenance Number: VMS-05-13 MAINTENANCE SERVICE CIRCULAR, VMS-05-13 DATED September 26, 2005, SUPERSEDES MAINTENANCE SERVICE CIRCULAR VMS-05-02
More information2006 Dynojet Research, Inc. All Rights Reserved. Spring Applied Air Release (SAAR) Brake Assembly Installation
2006 Dynojet Research, Inc. All Rights Reserved. This manual is copyrighted by Dynojet Research, Inc., hereafter referred to as Dynojet, and all rights are reserved. This manual, as well as the software
More informationAS/NZS 1927:1998 AS/NZS
AS/NZS 1927:2010 Incorporating Amendment No. 1 Australian/New Zealand Standard Pedal bicycles Safety requirements Superseding AS/NZS 1927:1998 AS/NZS 1927:2010 AS/NZS 1927:2010 This Joint Australian/New
More informationThis manual is to be given to the end user. Optional RFI filter. Drive. Stop. Thermal protection device. Start / Reset +DC.
3943 en - 2013.12 / c Optional RFI filter This manual is to be given to the end user Main contactor power supply Start / Reset Stop Thermal protection device Drive +DC BR Braking resistor DIGIDRIVE SK
More informationWPS02 Waste powder conveying with BIG-BAG station
En Operating instructions and spare parts list WPS02 Waste powder conveying with BIG-BAG station Translation of the original operating instructions Documentation WPS02 Copyright 2008 ITW Gema GmbH All
More informationATN3580 Series: Fixed Attenuator Pads
DATA SHEET ATN3580 Series: Fixed Attenuator Pads Applications Attenuators Features Specified flat response to 40 GHz Return loss > 15 db Available at 1-10, 12, 15, 20, 30, and 40 db Power handling to 1
More informationWenger Corporation 2011 Printed in USA 08/11 Part #158E006-02
Owner s Manual Conductor s Podium COntents Warranty.......................................... 2 Important User Information............................ 2 General....................................... 2
More informationSolar-Powered Battery Bank
Solar-Powered Battery Bank 1 Page D I S C L A I M E R O F L I A B I L I T Y A N D W A R R A N T Y This publication describes the author s opinions regarding the subject matter herein. The author and publisher
More informationPRG 350 Series Stainless Steel Regulators
PRG 350 Series Stainless Steel Regulators omega.com info@omega.com U.S.A. Headquarters: Servicing North America: Omega Engineering, Inc. Toll-Free: 1-800-826-6342 (USA & Canada only) Customer Service:
More informationAS/NZS :2011. Gate valves for waterworks purposes AS/NZS :2011. Part 1: Metal seated. Australian/New Zealand Standard
AS/NZS 2638.1:2011 Incorporating Amendment No. 1 Australian/New Zealand Standard Gate valves for waterworks purposes Part 1: Metal seated AS/NZS 2638.1:2011 AS/NZS 2638.1:2011 This joint Australian/New
More informationANTI-SYPHON VALVE INSTALLATION GUIDE
ANTI-SYPHON VALVE INSTALLATION GUIDE The information in this publication is provided for reference only. While every effort has been made to ensure the reliability and accuracy of the information contained
More informationPermissible Track Forces for Railway Vehicles
British Railways Board Page 1 of 11 Part A Synopsis This document prescribes design and maintenance requirements for traction and rolling stock and for on track plant to ensure that interactive forces
More informationAN RPM to TACH Counts Conversion. 1 Preface. 2 Audience. 3 Overview. 4 References
AN 17.4 RPM to TACH Counts Conversion 1 Preface 2 Audience 3 Overview 4 References This application note provides look up tables for the calculation of RPM to TACH Counts for use with the EMC2103, EMC2104,
More informationWalk-Behind Sprayer SL-80 & SL-80SS. Owner's Manual and Installation Instructions Original Instructions CAUTION
April 15, 2017 Lit. No. 74419, Rev. 00 Walk-Behind Sprayer SL-80 & SL-80SS Owner's Manual and Installation Instructions Original Instructions CAUTION Read this document before operating or servicing the
More informationWoody Brushcutter. 5 and 6 lateral models OPERATOR S & MAINTENANCE MANUAL
Woody Brushcutter 5 and 6 lateral models OPERATOR S & MAINTENANCE MANUAL All operators and maintenance personnel should read and understand this manual and all safety information before operating the attachment.
More information16000SIII Automatic Grease System
Manual # 99905495 16000SIII Automatic Grease System Effective 20120716 IOWA MOLD TOOLING CO., INC. PO Box 189 Garner, IA 50438 Tel: 641-923-3711 FAX: 641-923-2424 Website: http://www.imt.com Copyright
More information