KI-WON IND. CO., LTD.

Size: px
Start display at page:

Download "KI-WON IND. CO., LTD."

Transcription

1 .

2 Contents Brief History of KI-WON Production Item Certification Contact Point kiwon@kiwon.com TEL. : FAX : TEL. : FAX : /41

3 Brief History of KI-WON Sep Established at Pusan. May 1983 Starting manufacture of Sight Glass. May 1984 Starting manufacture of Water Eductor. Jul Starting manufacture of Steam Ejector. Feb Obtained K.R type approval certificate for Level Gauge. Jun Obtained B.V type approval certificate for Level Gauge. Aug Moved to Gimhae, Gyeong-Nam. Sep Obtained L.R type approval certificate for Level Gauge. Dec Obtained A.B.S type approval certificate for Level Gauge. Jan Obtained D.N.V type approval certificate for Level Gauge. Oct Shop approved by S.H.I for fabrication of Level Gauge, Sight Glass, Eductor, Surface Valve. Jan Completed Laboratory of Water Eductor and Steam Ejector. Feb Shop approved by H.H.I for fabrication of Level Gauge, Sight Glass, Eductor, Surface Valve. Nov Developed of marine Fresh Water Generator. Jun Certified by A.B.S for ISO Jan Obtained G.L type approval certificate for Eductor. 3/41

4 Production Item EDUTOR Water Eductor Steam Ejector Fresh Water Generator LEVEL GAUGE Flat Type Level Gauge Cylinder Type Level Gauge Float Dial Type Level Gauge Float Type Level Gauge SIGHT GLASS Flat Type Sight Glass Light Type Sight Glass SURFACE VALVE Welding Type Surface Valve Flange Type Surface Valve Sleeve Type Surface Valve DECK STAND 4/41

5 Water Eductor The Eductor is a passive equipment for Increasing the pump performance / stripping liquid with pump power. SERVICE : Tank Mixer, Sand & Mud Pumping, Cargo Oil Stripping, Ballast Water Stripping, Bilge Stripping, etc. MATERIAL : FC<Cast Iron>, FCD<Ductile Cast Iron>, SC<Cast Steel>, BC<Cast Bronze> or Customer s Request. STANDARD MATERIAL: BODY : Cast Iron, Cast Bronze, Cast Steel NOZZLE : Stainless Steel, Bronze. Required Information for Eductor Design : Total Suction Head(m) Calculated Discharge Head(m) Required Suction Capacity( m3 /hr) Motive Capacity & Pressure( m3 /hr, kg / cm3, MPa,Bar) Total Head (Meter Aqua)=Suction Head + Discharge Head Discharge Rate = Motive Rates + Suction Rates 5/41

6 Water Eductor <H-TYPE EDUCTOR> <V-TYPE EDUCTOR> KW-H CONNECTION(mm) DIMESION(mm) TYPE SIZE NO. A B C L l H H-ER-5O 1½x2x2½ H-ER-65 2x2½x H-ER-80 2½x3x H-ER-100 3x4x H-ER-125 4x5x H-ER-150 5x6x H-ER-200 6x8x H-ER-250 8x10x H-ER x10x H-ER x12x H-ER x14x H-ER x16x KW-V CONNECTION(mm) DIMESION(mm) TYPE SIZE NO. A B C L l H V-ER-5O 1½x2x2½ V-ER-80 2x3x V-ER-100 3x4x V-ER-125 4x5x V-ER-150A 4x6x V-ER-150B 5x6x V-ER-200A 5x8x V-ER-200B 6x8x V-ER-200C 6x8x V-ER-250 8x10x V-ER x12x V-ER x14x /41

7 Water Eductor HIGH PRESSURE TYPE SIZE(AxBxC) Driving Q'ty( m3 /hr) Suction Q'ty( m3 /hr) 40x50x65A 20 5~10 50x65x80A 30 10~20 65x80x80A 40 30~35 65x80x100A 50~60 35~40 80x100x100A 60~70 50~60 80x100x125A 70~80 60~70 100x125x150A 90~100 80~90 100x150x150A 110~120 90~ x150x200A 150~ ~ x200x200A 200~ ~ x200x250A 300~ ~ x250x300A 350~ ~ x300x350A 900~ ~ x350x450A 1000~ ~ x400x450A 1200~ ~1100 LOW PRESSURE TYPE SIZE(AxBxC) Driving Q'ty( m3 /hr) Suction Q'ty( m3 /hr) 150x150x200A 400~500 80~ x200x250A 550~ ~ x250x300A 900~ ~ x300x350A 1400~ ~ x350x450A 1900~ ~500 7/41

8 Steam Ejector BASIC CONSTRUCTION The jet ejector is very reliable equipment without moving part. It s a simple device & consists of 3 basic part, jet nozzle, suction chamber and diffuser. The movie fluid is supplied to the jet nozzle at constant pressure and expands nearly isotropic along the path of jet nozzle with increasing entropy, decreasing enthalpy, increasing specific volume and increasing velocity. The suction fluid is entrained in the suction chamber. The motive and suction fluids is mixed in a near isobaric process with increasing suction fluid velocity and decreasing motive fluid velocity. The result of this action is a mixture of driving and entrained fluids will be compressed in diffuser, with decreasing velocity and increasing entropy and enthalpy. FIG.1 In spite of its apparent simplicity, the operational characteristics are highly complex and can only be treated approximately due to the simplified assumption. This phenomena may be represented schematically shown in Firgure.1 8/41

9 Steam Ejector FIG.2 PERFORMANCE The performance of various type of steam jet ejectors are shown in FIGURE.3. The first decision to be made is the number of stages to be employed, this is generally based on the optimum operation in the view point of economics. FIG.3 The other factors which affect the performance : Motive steam pressure Cooling water temperature Capacity of the equipment Discharge pressure Inter-stage drainage 9/41

10 Steam Ejector SINGLE-STAGE KI-WON STEAM EJECTOR Single stage steam jet ejectors are designed to cover a suction pressure range from 760 to 75 mmhg absolute. The lower suction pressures are obtained by multi-stage steam jet ejectors. Design factor Motive steam pressure & temperature Suction pressure Suction flow rate Suction temperature Molecular fraction & molecular weight of suction gas Discharge pressure Material of construction FIG.4 FIG.5 10/41

11 Steam Ejector STEAM EJECTOR SIZE & DIMENSION STANDARD SIZES & DIMSNSION MODEL DIMESION CONNECTION SIZES WEIGHT A B C D MOTIVE SUCTION DISCHARGE (kg) KW-1E A 25A 25A 10 KW-1E A 40A 40A 15 KW-1E A 50A 50A 28 KW-1E A 65A 65A 32 KW-1E A 80A 80A 45 KW-1E A 100A 100A 80 KW-1E150A A 150A 125A 120 KW-1E150B A 150A 150A 150 FIG.6 11/41

12 Steam Ejector Pre-condenser with KI-WON Vacuum System If large condensable vapor loads must be handled, such as those from chilled water system & crystallizer, it is normally done with a condenser. It is normally used for the condensation vapor pressure range 50 to 100 Torr, condensable vapor quantities up to several ton/hr., such as the surface condenser with vacuum system for turbine-electrical power plant & the OVHD pre-condenser with vacuum package for dryer-petrochemical plant. The steam jet vacuum system removes the non-condensable gas and holds the vacuum pressure. FIG.7 FIG.8 12/41

13 Steam Ejector KI-WON Steam Jet Booster The vacuum pressure is depend on the temperature for the condenser cooling water. If low pressure is required, a steam jet booster is provided to increase the vacuum to the required point. The function of steam het vacuum booster is to compress the condensable vapor from the suction pressure to the intermediate pressure of intercondenser. 3 stage steam jet booster is designed in a suction pressure range 5 to 20 Torr. 13/41

14 Fresh Water Generator INTRODUCTION KI-WON distilling plants are used for oceangoing ship to produce high purity distilled water from sea water. The distilled water is required to furnish highpurity make-up water for the boiler and potable water for drinking, cooking, dishwashing, ablutionary and laundering purpose. The flash type evaporators become widely accepted for application in marine distilling plants because of low operating temperature in virtually scale-free performance with normal sea water. 14/41

15 Fresh Water Generator NOTE The allowable range of the driving steam pressure is 3 kg / cm2 minimum and 9 kg / cm2 maximum 15/41

16 Fresh Water Generator PRINCIPLE The main engine jacket cooling water circulates the outside of the vertical tube in heating section and the sea water to be distilled is sent to the bottom cover of this section. Then some of sea water is converted into vapor when it goes up through the heated rubes. The vapor, through the demisters, is condensed on the outer surface of the tubes of the distilling condenser and the resultant distillate is led to the suction of the distillate pump. In the meantime the non-condensable gases and brine are extracted and discharged to overboard by combination ejector. 16/41

17 Fresh Water Generator TECHNICAL SPECIFCATION OF KF TYPE 17/41

18 Fresh Water Generator DIMENSION LIST TYPE L B H C A APPROX. WEIGHT( kg ) EMPTY OPERATION EJECTOR PUMP KF KF KF KF KF KF KF KF KF KF /41

19 Flat Level Gauge SATISFACTORINESS OF SOLAS RULE REQUIRMENTS The gauge glass level indicator KIWON model has been developed to comply with the requirements of the SOLAS 2000 amendments. The gauge has been reviewed and in a suitable construction is accepted by marine classification authorities throughout the world. SPECIFICATIONS This gauge glasses level indicator can be used for tanks on board containing fluids which have a flash point above 60. This gauge glasses are to be fitted with self closing valve at the lower ends and at the top ends if these connected to the tanks below the maximum liquid level. When used for tank containing inflammable liquid the reflex glass to be heat resistant material. Hydraulic test pressure : 3 kg f/ cm2 Maximum Working temperature : /41

20 Flat Level Gauge PROPERTIES Viewing Window : Reflex glass COLUMN : Stainless Steel Self-Closing Valve : BRONZE ADJUST OF A : 35~40 mm Maximum Distance of Support : 1000 mm 20/41

21 Cylinder Level Gauge ( JIS F 7211 ) 1. Conforming to JIS standard. 2. Followings are the symbols to classify the gauge by type of upper position cock and valve type. 3. Hydraulic test pressure Body : 7 kgf/ cm2, Seat : 5.5 kgf/ cm2 21/41

22 Cylinder Level Gauge ( JIS F 7212 ) 1. Conforming to JIS standard. 2. Followings are the symbols to classify the gauge by type of upper position cock and valve type. 3. Hydraulic test pressure Body : 7 kgf/ cm2, Seat : 1.5 kgf/ cm2 22/41

23 Float Dial Level Gauge PRINCIPLE The float rises or lowers, according to the liquid level change in the vertical direction.(horizontal movement of the float is restricted by guide wire or protective pipe) Vertical movement of the float transmitted to the measuring wire, and dthen measuring wire is wounded daround dthe wire drum by means of gear mechanism and spring tension. STANDARD MODEL ANS SPECIFICAION MEASURING INDICATION ACCURACY WORKING CONDITION MATERIAL RAGNE SYSTEM (m) TEMP. PRESS BODY WIRE FLOAT 0~6 ONE-POINT ±15 mm 150 C 0.2 kg / cm2 AC SUS304 SUS304 0~6 ONE-POINT ±15 mm 150 C 0.2 kg / cm2 AC SUS304 SUS304 0~6 ONE-POINT ±15 mm 150 C 0.2 kg / cm2 AC SUS304 SUS304 0~6 ONE-POINT ±15 mm 150 C 0.2 kg / cm2 AC SUS304 SUS304 0~6 ONE-POINT ±15 mm 150 C 0.2 kg / cm2 AC SUS304 SUS304 0~6 ONE-POINT ±15 mm 150 C 0.2 kg / cm2 AC SUS304 SUS304

24 Float Dial Level Gauge APPLICATION Water Tank, L.O/D.O Tank etc. Dimensions of indicator body Body Drum Indicator Spring Gear Dimensions of float Wire Float 24/41

25 Float Dial Level Gauge Installing on top Installing on top GRATING Top of tank Top of tank Wire Guide pipe Float Bottom of tank Dead Zone Bottom of tank (ONLY) 25/41

26 Float Dial Level Gauge Installing on side 26/41

27 Float Dial Level Gauge Installing on side 27/41

28 Float Level Gauge ( JIS F 7217 A ) 28/41

29 Float Level Gauge ( JIS F 7217 B ) 29/41

30 Float Level Gauge ( JIS F 7217 C ) 30/41

31 Float Level Gauge ( KIWON TYPE ) 31/41

32 Flat Type Sight Glass MEETS SOLAS RULE REQUIREMENTS SPECIFICATIONS MATERIAL : Cast Iron, Tempered Flat Glass Working Pressure : 2 kg/cm2 Working Temperature : 200 Standard Connection Flange : JIS 5K 32/41

33 Light Type Sight Glass MEETS SOLAS RULE REQUIREMENTS SPECIFICATIONS MATERIAL : Cast Iron, Tempered Flat Glass Working Pressure : 2 kg/cm 2 Working Temperature : 200 Standard Connection Flange : JIS 5K Voltage : 220V Wattage : 60W Lamp Holder : E-27 Cable Gland : 20Cx2EA 33/41

34 Surface Valve 34/41

35 Surface Valve 35/41

36 Surface Valve WELDING TYPE FLANGE TYPE SLEEVE TYPE DIMENS ION TABLE N/D φd φd1 φd φd1 φd2 H H1 L FLANGE(JIS 5K) S LEEV E ΦOD ΦC T φ-h A B φd2 φd3 50A A A A A A A A REMARK 36/41

37 Deck Stand ( JIS F 3024 ) APPLICATION DECK STAND is handling check globe v/v or SURFACE V/V under deck to main deck by V/V EXTEND REACH ROD. 37/41

38 Certification 38/41

39 Certification ABS-LEVEL GAUGE DNV-LEVEL GAUGE 39/41

40 Certification BV-LEVEL GAUGE BV-SIGHT GLASS 40/41

41 Certification GL-EDUCTOR 41/41

Steam Jet Syphons. Index. Bulletin 2A

Steam Jet Syphons. Index. Bulletin 2A Jet s Jet s operate on the steam jet principle utilizing the energy of steam under pressure to pump, mix liquids and handle solids. They can be used for the handling of corrosive or abrasive liquids and

More information

Commercial-in-Confidence Ashton Old Baths Financial Model - Detailed Cashflow

Commercial-in-Confidence Ashton Old Baths Financial Model - Detailed Cashflow Year 0 1 2 3 4 5 6 7 8 9 10 11 12 13 Oct-16 Nov-16 Dec-16 Jan-17 Feb-17 Mar-17 Apr-17 May-17 Jun-17 Jul-17 Aug-17 Sep-17 Oct-17 2,038 2,922 4,089 4,349 6,256 7,124 8,885 8,885 8,885 8,885 8,885 8,885 9,107

More information

Quality, Safety and Environment

Quality, Safety and Environment Quality, Safety and Environment Global Valve Center B.V. is an independent, internationally operating, modern, flexible and service-oriented organization with over forty years of experience and expertise

More information

Peerless Pump FULL PRODUCT LINE. Brochure B Sterling Fluid Systems (USA), Inc.

Peerless Pump FULL PRODUCT LINE. Brochure B Sterling Fluid Systems (USA), Inc. Peerless Pump FULL PRODUCT LINE Sterling Fluid Systems (USA), Inc. Brochure B-1270 Vertical Industrial and Process Axial and Mixed Flow for Large Volume Pumping Encased (Can ) Water and Process Liquid

More information

YARWAY NARVIK MODEL 88 SPID SMALL PIPE INLINE DESUPERHEATER

YARWAY NARVIK MODEL 88 SPID SMALL PIPE INLINE DESUPERHEATER A wide range of desuperheaters, pneumatic actuators, strainers to satisfy all specifications of the power, pulp and paper industry and process gas applications FEATURES Fabricated construction Special

More information

OPERATIONS SEAFARER CERTIFICATION GUIDANCE NOTE SA MARITIME QUALIFICATIONS CODE. Deck: Ship s Power Plants

OPERATIONS SEAFARER CERTIFICATION GUIDANCE NOTE SA MARITIME QUALIFICATIONS CODE. Deck: Ship s Power Plants Page 1 of 8 Compiled by Approved by Chief Examiner Syllabus Committee: 26 February 2013 OPERATIONS SEAFARER CERTIFICATION GUIDANCE NOTE SA MARITIME QUALIFICATIONS CODE Deck: Page 2 of 8 KNOWLEDGE, UNDERSTANDING

More information

Axial and Mixed Flow Pumps for Large Volume Pumping

Axial and Mixed Flow Pumps for Large Volume Pumping Vertical Industrial and Process Vertical close coupled single or multi-stage turbine pumps. Axial and Mixed Flow for Large Volume Pumping Vertical pumps for handling water in large volumes. Mixed flow

More information

ACD6. Std Line. Product Description. Max differential pressure: 7 bar Circulation, lubrication and transfer ACD GB

ACD6. Std Line. Product Description. Max differential pressure: 7 bar Circulation, lubrication and transfer ACD GB ACD6 Std Line Product Description Flow volume: 10-42 l/min Max differential pressure: 7 bar Applications: Circulation, lubrication and transfer 1. Applications 1.1 Functionality The ACD pumps come in two

More information

Float valve Type HFI. Data sheet

Float valve Type HFI. Data sheet Data sheet Float valve ype is a high pressure float valve with internal liquid measuring device. he float valve is designed for direct flange mounting or welding on to plate heat exchanger type condensers,

More information

Welcome to Nordan Marine A/S. Nordan Marine Replacement Pump for type CG for: Your partner in Marine and Offshore Pumps

Welcome to Nordan Marine A/S. Nordan Marine Replacement Pump for type CG for: Your partner in Marine and Offshore Pumps Welcome to Nordan Marine A/S Nordan Marine Replacement Pump for type CG for: Hamworthy Pump Thune Eureka Pump Kværner Eureka Pump Wärtsilä Pump Your partner in Marine and Offshore Pumps Nordan Marine is

More information

ACF5. Std Line. Product Description. Max differential pressure: 16 bar Circulation, lubrication and transfer

ACF5. Std Line. Product Description. Max differential pressure: 16 bar Circulation, lubrication and transfer ACF5 Std Line Product Description Flow volume: 310-2900 l/min Max differential pressure: 16 bar Applications: Circulation, lubrication and transfer ALSO VALID FOR PUMP SERIES UCF Generation 5 1. Applications

More information

ACF5. Std Line. Product Description. Max differential pressure: 16 bar Circulation, lubrication and transfer ACF GB

ACF5. Std Line. Product Description. Max differential pressure: 16 bar Circulation, lubrication and transfer ACF GB ACF5 Std Line Product Description Flow volume: 310-2900 l/min Max differential pressure: 16 bar Applications: Circulation, lubrication and transfer 1. Applications 1.1 Functionality The ACF pumps are used

More information

SILI PUMP, Your reliable one-stop supplier of marine pumps.

SILI PUMP, Your reliable one-stop supplier of marine pumps. SILI PUMP, Your reliable one-stop supplier of marine pumps. Shanghai SILI PUMP Industry Co., Ltd. Add: No.128 Jinyuan Road, 201518, Shanghai, China (Jinyuan Industry Area) Tel: 0086-21-39109967, fax: 0086-21-39109967

More information

COMPARISON OF FIXED & VARIABLE RATES (25 YEARS) CHARTERED BANK ADMINISTERED INTEREST RATES - PRIME BUSINESS*

COMPARISON OF FIXED & VARIABLE RATES (25 YEARS) CHARTERED BANK ADMINISTERED INTEREST RATES - PRIME BUSINESS* COMPARISON OF FIXED & VARIABLE RATES (25 YEARS) 2 Fixed Rates Variable Rates For Internal Use Only. FIXED RATES OF THE PAST 25 YEARS AVERAGE RESIDENTIAL MORTGAGE LENDING RATE - 5 YEAR* (Per cent) Year

More information

COMPARISON OF FIXED & VARIABLE RATES (25 YEARS) CHARTERED BANK ADMINISTERED INTEREST RATES - PRIME BUSINESS*

COMPARISON OF FIXED & VARIABLE RATES (25 YEARS) CHARTERED BANK ADMINISTERED INTEREST RATES - PRIME BUSINESS* COMPARISON OF FIXED & VARIABLE RATES (25 YEARS) 2 Fixed Rates Variable Rates FIXED RATES OF THE PAST 25 YEARS AVERAGE RESIDENTIAL MORTGAGE LENDING RATE - 5 YEAR* (Per cent) Year Jan Feb Mar Apr May Jun

More information

BEV. Deep well vertical pumps. 3. Design. 1. Fields of Application. 4. Designation. 2. Operating Data

BEV. Deep well vertical pumps. 3. Design. 1. Fields of Application. 4. Designation. 2. Operating Data Type series booklet CTI-2000/00 [09-2010] BEV Deep well vertical pumps 1. Fields of Application BEV are vertical multistage centrifugal pumps designed for deep well, ditches and tanks to pump clean liquids

More information

Penberthy Automatic Injectors

Penberthy Automatic Injectors Hot water injectors used primarily as boiler feed pumps but also in numerous other applications for pumping liquids and discharging at high pressure and temperature Features Durable construction. Compact

More information

Fundamentals of steam turbine systems

Fundamentals of steam turbine systems Principles of operation Fundamentals of steam turbine systems - The motive power in a steam turbine is obtained by the rate of change in momentum of a high velocity jet of steam impinging on a curved blade

More information

SIHI prime - Side Channel Pumps Self-priming, segmental type with very low NPSH

SIHI prime - Side Channel Pumps Self-priming, segmental type with very low NPSH SIHI prime - Side Channel Pumps Self-priming, segmental type with very low NPSH CEH-X 1201 3608 TECHICAL DATA Capacity: Delivery head: Speed: from 0.4 up to 7.5 m³/h from 10 up to 322 m 1450 rpm (max.

More information

CONTROL VALVE STANDARD SPECIFICATION

CONTROL VALVE STANDARD SPECIFICATION CONTROL VALVE STANDARD SPECIFICATION QUICK CHANGE TYPE 2-WAY GLOBE VALVE YAD-122Q1 Series http://www.proval.co.kr PROVAL Co., Ltd. [B-1] TOP GUIDE SINGLE SEATED TYPE GENERAL The design of Quick Change

More information

ACG7. Std Line. Product Description. Max differential pressure: 16 bar Circulation, lubrication and transfer ACG GB

ACG7. Std Line. Product Description. Max differential pressure: 16 bar Circulation, lubrication and transfer ACG GB ACG7 Std Line Product Description Flow volume: 80-1200 l/min Max differential pressure: 16 bar Applications: Circulation, lubrication and transfer 1. Applications 1.1 Functionality The Std Line (standard)

More information

UNIT IV INTERNAL COMBUSTION ENGINES

UNIT IV INTERNAL COMBUSTION ENGINES UNIT IV INTERNAL COMBUSTION ENGINES Objectives After the completion of this chapter, Students 1. To know the different parts of IC engines and their functions. 2. To understand the working principle of

More information

L_Series. L_500 Liquid Ring Compressors

L_Series. L_500 Liquid Ring Compressors L_Series L_500 Liquid Ring Compressors L_500 Compression of process gases In 2002 The Nash Engineering Company in the USA and elmo vacuum technology GmbH, a Siemens subsidiary in Germany, united to form

More information

Wafer, Semi Lug, Lug and Flanged Type

Wafer, Semi Lug, Lug and Flanged Type Year : Wafer, Semi Lug, Lug and Flanged Type Page 1 Year : Specification Description : GVC concentric rubber lined butterfly valves suitable for bi-directional flow and bubble tight shut-off at full rated

More information

Si Engineering GREAT Solutions. Process and steam safety valves to PED and DIN/EN standards

Si Engineering GREAT Solutions. Process and steam safety valves to PED and DIN/EN standards Engineering GREAT Solutions Process and steam safety valves to PED and DIN/EN standards Features Basic valve for low pressure Cost-efficient IMI Bopp & Reuther low pressure safety valve: > Semi nozzle

More information

Self-operated Pressure Regulators Type Universal Pressure Reducing Valve

Self-operated Pressure Regulators Type Universal Pressure Reducing Valve Self-operated Pressure Regulators Type 41-23 Universal Pressure Reducing Valve ANSI version Application Pressure regulators for set points from 0.75 to 400 psi (0.05 to 28 bar) Valves in NPS ½ to 4 (DN

More information

SIHI prime - Side Channel Pumps Self-priming, segmental type

SIHI prime - Side Channel Pumps Self-priming, segmental type SIHI prime - Side Channel Pumps Self-priming, segmental type AKH-X 1201 3606 TECHICAL DATA Capacity: Delivery head: Speed: from 0.4 up to 7.5 m³/h from 10 up to 242 m 1450 rpm (max. 1800 rpm) Temperature:

More information

ANNEX 23. RESOLUTION MEPC.187(59) Adopted on 17 July 2009

ANNEX 23. RESOLUTION MEPC.187(59) Adopted on 17 July 2009 RESOLUTION MEPC.187(59) Adopted on 17 July 2009 AMENDMENTS TO THE ANNEX OF THE PROTOCOL OF 1978 RELATING TO THE INTERNATIONAL CONVENTION FOR THE PREVENTION OF POLLUTION FROM SHIPS, 1973 (Amendments to

More information

HAWLE-AIR RELEASE VALVES

HAWLE-AIR RELEASE VALVES HAWLE-AIR RELEASE VALVES HAWLE-AIR RELEASE VALVES Contents: Dimensions of Air Release Valve Page 2 Why use Air Release Valves? Page 3 Application: Potable water Air Release Valves, DN 1" - DN 2" Page 4

More information

1.1 PURPOSE A. This section is intended to define the general installation and minimum product requirements for hydronic and steam valves.

1.1 PURPOSE A. This section is intended to define the general installation and minimum product requirements for hydronic and steam valves. Date Description of Change Pages / Sections Modified ID 6/15/16 Entire document - mgl44 PART 1 - INTRODUCTION 1.1 PURPOSE A. This section is intended to define the general installation and minimum product

More information

M A D E I N N O R W A Y

M A D E I N N O R W A Y EJECTORS EDUCTORS M A D E I N N O R W A Y Norwegian traditions a business with deep roots TeamTec is continuing a tradition of marine industrial activity at Tangen in Tvedestrand, Norway, dating back to

More information

High pressure float valve, type HFI REFRIGERATION AND AIR CONDITIONING. Technical leaflet

High pressure float valve, type HFI REFRIGERATION AND AIR CONDITIONING. Technical leaflet High pressure float valve, type HFI REFRIGERAION AND AIR CONDIIONING echnical leaflet Contents Page Introduction........................................................................................3

More information

Direct Contact Desuperheaters

Direct Contact Desuperheaters Control Description Spirax Sarco direct contact desuperheaters reduce the temperature of superheated steam to produce steam temperatures approaching saturation temperature to cool the superheated steam,

More information

Application & Reference Data Typical Specifications. Section 914 Vertical Turbine Fire Pump

Application & Reference Data Typical Specifications. Section 914 Vertical Turbine Fire Pump Section 914 Page 101 Supersedes Section 913 Page 101 Dated November 1, 199p Application & Reference Data Typical Specifications Section 914 Section 914 Page 102 Supersedes Section 913 Page 102 Dated November

More information

Improve Steam Turbine Efficiency

Improve Steam Turbine Efficiency Improve Steam Turbine Efficiency Understand the factors that affect steam consumption Steam are a major energy consumer. Optimising process operating conditions can considerably improve turbine water rate,

More information

Brief Introduction of The Selling Gen-set

Brief Introduction of The Selling Gen-set Brief Introduction of The Selling Gen-set Ⅰ General Information The power plant started to operate on 29, Sep., 1997 and the stop operation date was 26, Jul., 2007 The gas turbine output is 37MW and steam

More information

MILITARY STANDARD SCHEDULE OF PIPING, VALVES, FITTINGS, AND ASSOCIATED PIPING COMPONENTS FOR NAVAL SURFACE SHIPS

MILITARY STANDARD SCHEDULE OF PIPING, VALVES, FITTINGS, AND ASSOCIATED PIPING COMPONENTS FOR NAVAL SURFACE SHIPS NOTICE OF CHANGE INCH-POUND ) 8 July 2002 MILITARY STANDARD SCHEDULE OF PIPING, VALVES, FITTINGS, AND ASSOCIATED PIPING COMPONENTS FOR NAVAL SURFACE SHIPS TO ALL HOLDERS OF : 1. THE FOLLOWING PAGES OF

More information

ILN, ILNC. In Line vertical pumps. ILN single suction ILN double suction ILNC. 1. Fields of Application. 3. Design. 4. Designation. 2.

ILN, ILNC. In Line vertical pumps. ILN single suction ILN double suction ILNC. 1. Fields of Application. 3. Design. 4. Designation. 2. Type series booklet CTI-2600/04 [04-2017] ILN, ILNC In Line vertical pumps ILN single suction ILN double suction ILNC sizes 65/ to 250/... sizes 300/ all sizes 1. Fields of Application Suitable for a wide

More information

SP SERIES SELF-PRIMING MAG DRIVE

SP SERIES SELF-PRIMING MAG DRIVE SP SERIES SELF-PRIMING MAG DRIVE spend less time waiting. and more time pumping. year Big on power yet short on energy consumption, the SP Series from Finish Thompson is one of the most versatile and economical

More information

Direct Contact Desuperheaters

Direct Contact Desuperheaters Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

VOLCANO CO., LTD.

VOLCANO CO., LTD. 5 no. VOLCANO CO., LTD. http://www.volcano.co.jp/english/ 1-3-38 Nonaka-kita,Yodogawa-ku, Osaka, 532-0034,Japan Tel : +81-6-6392-5541 / Fax : +81-6-6396-7609 / E-mail : info-m@volcano.co.jp AHTS PSV FPSO

More information

Waste Lubricating Oil Purification and Recovery

Waste Lubricating Oil Purification and Recovery Waste Lubricating Oil Purification and Recovery It may be surprising to note that, under normal circumstances, lubricating oil cannot be easily destroyed; it only gets dirty and is easily contaminated

More information

USER INFORMATION, CURRENT RULE CHAPTERS AND INDEX

USER INFORMATION, CURRENT RULE CHAPTERS AND INDEX RULES FOR CLASSIFICATION OF Ships MAIN CHANGES JANUARY 2013 General A complete list of current rule chapters including revision dates is presented in Pt.0 Ch.1 Sec.2. The listing below contains only chapters

More information

BERMAD Waterworks. Pressure Relief/Sustaining Valve. Model: WW Series. Features and Benefits. Major Additional Features

BERMAD Waterworks. Pressure Relief/Sustaining Valve. Model: WW Series. Features and Benefits. Major Additional Features Pressure Relief/Sustaining Valve Prioritizing pressure zones Ensuring controlled pipeline fill-up Preventing pipeline emptying Pump overload & cavitation protection Safeguarding pump minimum flow Excessive

More information

Self-operated Pressure Regulators Type Universal Excess Pressure Valve

Self-operated Pressure Regulators Type Universal Excess Pressure Valve Self-operated Pressure Regulators Type 41-73 Universal Excess Pressure Valve ANSI version Application Pressure regulator for set points from 0.75 to 400 psi (0.05 to 28 bar) Valves in NPS ½ to 4 (DN 15

More information

BLIND FLANGE VALVE The improved top quality 100% tight blind flange valve. Easy to operate and reliable in use.

BLIND FLANGE VALVE The improved top quality 100% tight blind flange valve. Easy to operate and reliable in use. The improved top quality 100% tight blind flange valve. Easy to operate and reliable in use. Applications: Crude oil product. LPG and LNG carriers. Chemical Tankers. Rigs. Refineries. Terminals. Chemical

More information

WOOSUNG INSULATION INDUSTRY

WOOSUNG INSULATION INDUSTRY WS-201712 ISO 9001:2015 WOOSUNG INSULATION INDUSTRY 46028 132, MYEONGNYESANDAN 5-RO, JANGAN-EUP, GIJANG-KUN, BUSAN, KOREA TEL : +82 51 753-2772 FAX : +82 51 753-2771 HAMEPAGE : http://www.wsins.co.kr

More information

Parts Manual. PTAC PD Series (Electronic Controls) Packaged Terminal Air Conditioners Packaged Terminal Heat Pumps Serial Number LEAP and Later MODELS

Parts Manual. PTAC PD Series (Electronic Controls) Packaged Terminal Air Conditioners Packaged Terminal Heat Pumps Serial Number LEAP and Later MODELS Parts Manual PTAC PD Series (Electronic Controls) Packaged Terminal Air Conditioners Packaged Terminal Heat Pumps Serial Number LEAP and Later MODELS PDE07K**B-A PDE07R**B-A PDE09K**B-A PDE09R**B-A PDE12K**B-A

More information

CROSBY STYLE JB PRESSURE RELIEF VALVE

CROSBY STYLE JB PRESSURE RELIEF VALVE A large orifice pressure relief valve engineered to provide high quality, dependable overpressure protection for air, gas, vapor and steam applications FEATURES Ten size product range is the broadest available.

More information

SIHI LPH-X - Liquid Ring Vacuum Pump Two Stage

SIHI LPH-X - Liquid Ring Vacuum Pump Two Stage - Liquid Ring Vacuum Pump Two Stage LPH 45008, LPH 45311, LPH 45316 Pressure Range: Suction Volume: 33 to 1013 mbar 55 to 258 m³/h CONSTRUCTION Sterling SIHI liquid ring vacuum pumps have a simple but

More information

Bristol: A History & Future.

Bristol: A History & Future. Fire Pumps Bristol: A History & Future. In 1971, seven emirates joined forces to create the United Arab Emirates, with the goal of becoming a growing leader on an international scale. The UAE s focus has

More information

Content : 4.1 Brayton cycle-p.v. diagram and thermal efficiency. 4Marks Classification of gas turbines.

Content : 4.1 Brayton cycle-p.v. diagram and thermal efficiency. 4Marks Classification of gas turbines. Content : 4.1 Brayton cycle-p.v. diagram and thermal efficiency. 4Marks Classification of gas turbines. 4.2 Construction and working of gas turbines i) Open cycle ii) Closed cycle gas Turbines, P.V. and

More information

SPECIFY THE RIGHT HOT OIL PUMP FOR YOUR APPLICATION

SPECIFY THE RIGHT HOT OIL PUMP FOR YOUR APPLICATION SPECIFY THE RIGHT HOT OIL PUMP FOR YOUR APPLICATION Hot oil pumps are used in a range of industries, with their main user being the heat transfer oil customer. Often, oil temperatures will exceed 500 F

More information

Squirrel Cage Induction Motors MA - A4 - BB - B4 - B5 SERIES SIZES. MarelliMotori ASI.CT.033.2

Squirrel Cage Induction Motors MA - A4 - BB - B4 - B5 SERIES SIZES. MarelliMotori ASI.CT.033.2 Marine Motors Three Phase Squirrel Cage Induction Motors MA - A4 - BB - B4 - B5 SERIES 63-400 SIZES MarelliMotori ASI.CT.033.2 CONTENTS Page STANDARDS 5 ESSENTIAL AND NON-ESSENTIAL SERVICE 5 CLASSIFICATION

More information

SIHI LPH-X - Liquid Ring Vacuum Pump Two Stage

SIHI LPH-X - Liquid Ring Vacuum Pump Two Stage - Liquid Ring Vacuum Pump Two Stage 45008, 45311, 45316 Pressure Range: Suction Volume: 33 to 1013 mbar 55 to 258 m³/h CONSTRUCTION Sterling SIHI liquid ring vacuum pumps have a simple but robust construction

More information

(3) (4) (6) (5) (10) (9) (8) (7)

(3) (4) (6) (5) (10) (9) (8) (7) 3. Fuel System A: GENERAL The fuel pressurized by the fuel tank inside pump is delivered to each fuel injector by way of the fuel pipe and fuel filter. Fuel injection pressure is regulated to an optimum

More information

Pressure control valve Type KDC

Pressure control valve Type KDC Data sheet Pressure control valve Type KDC 65-00 The KDC valve is a pressure control valve. The valve controls the discharge pressure of the compressor to ensure fast build-up of pressure and lubrication

More information

XID ENHANCEMENT SYSTEM IMPROVED EFFICIENCY AND PERFORMANCE

XID ENHANCEMENT SYSTEM IMPROVED EFFICIENCY AND PERFORMANCE IMMERSION FIRED HOT WATER BOILER April 1, 2003 GENERAL DESCRIPTION The Sellers immersion fired hot water boiler is a horizontal, single pass, firetube boiler designed to burn natural gas. The unique burner

More information

INSTRUCTION MANUAL OIL SEALED ROTARY VACUUM PUMP MODEL PKS-016 PKS-030 PKS-070

INSTRUCTION MANUAL OIL SEALED ROTARY VACUUM PUMP MODEL PKS-016 PKS-030 PKS-070 INSTRUCTION MANUAL OIL SEALED ROTARY VACUUM PUMP MODEL PKS-016 PKS-030 PKS-070 Components division ULVAC, Inc. Table of Contents 1. Inspection 4 2. Mounting 5 3. Oil filling 5 4. Electrical connections

More information

Horizontal Double Suction Volute Pump Type CN. Pipe line

Horizontal Double Suction Volute Pump Type CN. Pipe line PUMP Horizontal Double Suction Volute Pump Type APPLICATIONS Buildings Irrigation Water supply Drainage Water circulation Fire fighting Air conditioning Water supply Drainage Waterworks Water intake Booster

More information

The pumping action of the B series lobe displacement pump is achieved thanks to the counter-rotation of

The pumping action of the B series lobe displacement pump is achieved thanks to the counter-rotation of INDUSTRY APPLICATION Rotary lobe pumps type B are positive displacement pumps for liquids of any viscosity with lubricating and non-lubricating properties. Lobe pumps are used in the chemical, pharmaceutical

More information

Peerless Pump FIRE PUMPS. Horizontal Split-Case, Vertical Turbine, In-Line and End Suction. Sterling Fluid Systems (USA), Inc.

Peerless Pump FIRE PUMPS. Horizontal Split-Case, Vertical Turbine, In-Line and End Suction. Sterling Fluid Systems (USA), Inc. Peerless Pump FIRE PUMPS Split-Case, Vertical Turbine, In-Line and End Suction Sterling Fluid Systems (USA), Inc. Brochure B-1500 Fire Protection Fire Pump Units & Packaged Systems You have decided to

More information

Self-operated Pressure Regulators Type Universal Excess Pressure Valve

Self-operated Pressure Regulators Type Universal Excess Pressure Valve Self-operated Pressure Regulators Type 41-73 Universal Excess Pressure Valve Application Pressure regulators for set points from 0.05 to 8 bar Valve nominal sizes DN 15 to 100 Nominal pressure PN 16 to

More information

Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23

Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23 Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23 ANSI version Application Pressure regulators for set points from 0.075 to 400 psi (5 mbar to 28 bar) Valves in NPS ½ to 4

More information

SECTION H3 TRAYMASTER SERIES DEAERATORS

SECTION H3 TRAYMASTER SERIES DEAERATORS SECTION H3 TRAYMASTER SERIES DEAERATORS SAMPLE SPECIFICATIONS PART 1 GENERAL... H3-12 1.1 Packaged Deaerator Specification... H3-12 PART 2 PRODUCTS... H3-12 2.1 Deaerator... H3-12 2.2 Deaerator Vessel...

More information

HYDRAULIC SEPARATOR PRODUCTION RANGE. Code Size Max. flow rate (l/h) " "1/ "1/ " 8.

HYDRAULIC SEPARATOR PRODUCTION RANGE. Code Size Max. flow rate (l/h)  1/ 1/  8. HYDRAULIC SEPARATOR CT0617.0_03 EN March 2016 o o o Threaded versions equipped with flat seat F union connections, therefore, easy installation and/or maintenance; Self-cleaning: Dirt separator equipped

More information

ST. VINCENT AND THE GRENADINES

ST. VINCENT AND THE GRENADINES ST. VINCENT AND THE GRENADINES MARITIME ADMINISTRATION CIRCULAR N POL 012 AMENDMENTS OF THE SUPPLEMENT (FORM A AND B) OF THE IOPP CERTIFICATE TO: SHIPOWNERS, SHIPS OPERATORS AND MANAGERS, MASTERS, RECOGNIZED

More information

IMMERSION FIRED HOT WATER BOILER

IMMERSION FIRED HOT WATER BOILER 918 W WALNUT ST, DANVILLE, KENTUCKY 40422-0048 PHONE (859) 236-3181 www.sellersmfg.com SPECIFICATION SHEET NO. 8301 IMMERSION FIRED HOT WATER BOILER GENERAL DESCRIPTION The Sellers immersion fired S-Series

More information

Mohammad Faisal Haider. Department of Mechanical Engineering Bangladesh University of Engineering and Technology

Mohammad Faisal Haider. Department of Mechanical Engineering Bangladesh University of Engineering and Technology Mohammad Faisal Haider Lecturer Department of Mechanical Engineering Bangladesh University of Engineering and Technology Steam Turbine 2 Vapor Power Cycle 4 5 Steam Turbine A steam turbine is prime mover

More information

Cash Valve. Type G-60. High Capacity Pressure Regulator. Flow Control. Issued - February 2001 CAVMC-0511-US-0609 ISO 9001 Certified

Cash Valve. Type G-60. High Capacity Pressure Regulator. Flow Control. Issued - February 2001 CAVMC-0511-US-0609 ISO 9001 Certified Cash Valve Type G-60 High Capacity Pressure Regulator Issued - February 2001 CAVMC-0511-US-0609 ISO 9001 Certified Flow Control Type G-60 High Capacity Pressure Reducing And Regulating Valve Description

More information

PA SERIES END SUCTION CENTRIFUGAL PUMP SINGLE STAGE BACK PULL-OUT DIN24255 THONG FATT JAYA MACHINERY HARDWARE SDN. BHD.

PA SERIES END SUCTION CENTRIFUGAL PUMP SINGLE STAGE BACK PULL-OUT DIN24255 THONG FATT JAYA MACHINERY HARDWARE SDN. BHD. END SUCTION CENTRIFUGAL PUMP SINGLE STAGE BACK PULL-OUT DIN24255 50HZ OR 60HZ PA SERIES APPLICATIONS PA Series pumps can be used for the following services in commercial, residential, agriculture, industrial,

More information

Pamphlet M0000. Three-in-One Pressure Regulator, Separator, and Steam Trap COSPECTR PRESSURE REDUCING VALVES

Pamphlet M0000. Three-in-One Pressure Regulator, Separator, and Steam Trap COSPECTR PRESSURE REDUCING VALVES Pamphlet M0000 COSPECTR PRESSURE REDUCING VALVES Three-in-One Pressure Regulator, Separator, and Steam Trap COSPECT: Three-in-One Design A Product of Advanced Fluid Control Technology Three sub-units combine

More information

Flow volume: l/min Max differential pressure: 16 bar Applications: Lubrication, circulation and transfer

Flow volume: l/min Max differential pressure: 16 bar Applications: Lubrication, circulation and transfer Std Line ACE3 Screwpump Series Product description Flow volume: 15-180 l/min Max differential pressure: 16 bar Applications: Lubrication, circulation and transfer The Std Line (standard) ACE pumps come

More information

K19-CP. Marine Generator Sets. The Right Technology. Matters. Specifications. Dimensions. Ratings. Engine Model Alternator

K19-CP. Marine Generator Sets. The Right Technology. Matters. Specifications. Dimensions. Ratings. Engine Model Alternator K19-CP Marine Generator Sets Specifications Engine Model Alternator AVR Type Operating Fuel Agency Approvals Emissions Cummins KTA19-D(M1) Newage HCM534E MX341 #2 Diesel, MGO ABS, BV, DNV, GL, LR IMO Tier

More information

Ignition energy enough for igniting the mixture is available, such as sparkles generated by friction and impaction, electric arc or hot surfaces.

Ignition energy enough for igniting the mixture is available, such as sparkles generated by friction and impaction, electric arc or hot surfaces. Elementary knowledge of safety and explosion protection 1.1 Characteristics of explosion A phenomenon, in which substances are converted from one state into another and massive energy and sounds are instantaneously

More information

Standard Duty A.T.S.A. - Temp Desuperheater Model 24 / 34

Standard Duty A.T.S.A. - Temp Desuperheater Model 24 / 34 Narvik-Yarway covers requirements for desuperheaters, pneumatic actuators, strainers with a wide range of models, sizes and materials to satisfy all the specifications of the power, pulp & paper industry

More information

Gauges, Sight Glasses and Vacuum Breakers

Gauges, Sight Glasses and Vacuum Breakers Gauges, Sight Glasses and Vacuum Breakers Gauges, Sight Glasses and Vacuum Breakers Gauges Pressure gauges Pressure gauges should be installed in at least the following situations: Upstream of a pressure

More information

KBF100. General Service Butterfly Valve KBF. Hot to Order System KOPECS CO.,LTD. EASBL TEL : FAX :

KBF100. General Service Butterfly Valve KBF. Hot to Order System KOPECS CO.,LTD. EASBL TEL : FAX : KBF100 General Service Butterfly Valve KOPECS Butterfly Valve Features KOPECS unique seat sealing esign offers frictional contact between valve disc and seat: ㆍ ㆍ Zero leakage,tight shut off ㆍ Lower torque

More information

ANSI version. The valve closes when the differential pressure rises

ANSI version. The valve closes when the differential pressure rises Self-operated Regulators Series 42 Differential Pressure Regulator with Type 2424/Type 2428 Actuator and Type 2422 Valve Type 42-24 A Type 42-24 B Type 42-28 A Type 42-28 B ANSI version Application For

More information

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps... PUMPS FOR INDUSTRY CONTNTS: The Vertical Pump Specialists Introduction & User List Product Overview Vertical Process Pumps... Series 600 Vertical Sewage Pumps... Series 700 Vertical Sump Pumps... Series

More information

HORIZONTAL MULTI STAGE PUMPS

HORIZONTAL MULTI STAGE PUMPS HORIZONTAL MULTI STAGE PUMPS APPLICATIONS Water supply Hot/cold water Sprinklers Agriculture Construction Factories Mines Boiler feed Other general high pressure services *Please choose the model, referring

More information

DRAFT. Total Month Average Point (MAP) A Massage 4/30/2014 8/1/2015 A CENTER E

DRAFT. Total Month Average Point (MAP) A Massage 4/30/2014 8/1/2015 A CENTER E Total Month Average Point (MAP) A Massage 4/30/2014 8/1/2015 A CENTER E 2.25 2.00 2.00 2.25 2.00 2.00 1.00 2.25 2.00 2.25 2.00 A Massage 10/31/2017 9/1/2015 B MEZZANINE 2.25 2.00 2.00 2.25 2.25 2.25 2.25

More information

Float-operated condensate pump ARI Condensate pump (mechanical) Displacement: 16,5-20 litres. High temperature steel. Stainless steel.

Float-operated condensate pump ARI Condensate pump (mechanical) Displacement: 16,5-20 litres. High temperature steel. Stainless steel. Float-operated condensate pump ARI Condensate pump (mechanical) Displacement: 16,5-20 litres Condensate pump No electricity required / float-operated PN 16 (82.691) Body: Jacket P235GH-TC, Bottom flanges

More information

Distillation process of Crude oil

Distillation process of Crude oil Distillation process of Crude oil Abdullah Al Ashraf; Abdullah Al Aftab 2012 Crude oil is a fossil fuel, it was made naturally from decaying plants and animals living in ancient seas millions of years

More information

Waterous S100 Single Stage Pump

Waterous S100 Single Stage Pump The S100 Series end suction fire pump provides versatility in a smaller package. With a capacity of 2000 GPM (7570 L/min), the S100 Features a dynamic yet compact design, incorporating a ductile iron body

More information

RULES FOR THE CONSTRUCTION AND CLASSIFICATION OF SHIPS IDENTIFIED BY THEIR MISSIONS CHAPTERS APPROACH

RULES FOR THE CONSTRUCTION AND CLASSIFICATION OF SHIPS IDENTIFIED BY THEIR MISSIONS CHAPTERS APPROACH PART II RULES FOR THE CONSTRUCTION AND CLASSIFICATION OF SHIPS IDENTIFIED BY THEIR MISSIONS TITLE 47 SUPPLY VESSELS SECTION 6 PIPING CHAPTERS A B C D E F G H T APPROACH MATERIALS AND MANUFACTURE - See

More information

High Flow Safety Valves

High Flow Safety Valves High Flow Safety Valves Engineering GREAT Solutions Process and steam safety valves to PED and DIN/EN standards High Flow Safety Valves Valve summary Si 6301 Size DN 20 to DN 150 Set Pressure up to16 bar

More information

Vertical Pumps for the Oil & Gas Industry

Vertical Pumps for the Oil & Gas Industry Vertical Pumps for the Oil & Gas Industry Lenntech info@lenntech.com Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289 ITT API Expert ITT Commitment ITT is committed to the Oil and Gas market,

More information

Up and Down Months of the Stock Market

Up and Down Months of the Stock Market Up and Down Months of the Stock Market 1926-2017 Positive years (66) in the stock market were not good all year long and losing years (24) were not losers throughout the year. Winning years produce losing

More information

Pumps, fans, motors, strainers. Turbo-pumps Hydro-ejectors Fans Ducts for fire brigades...299

Pumps, fans, motors, strainers. Turbo-pumps Hydro-ejectors Fans Ducts for fire brigades...299 Pumps, fans, motors, strainers Strainers...290 Strainers - Accessories...292 Filters...293 Turbo-motors - High speed, hydraulic...294 Turbo-pumps...295 Hydro-ejectors...296 Fans...297 Ducts for fire brigades...299

More information

ProSimTechs PROCESS SIMULATION TECHNICS

ProSimTechs PROCESS SIMULATION TECHNICS PROCESS SIMULATION TECHNICS Rigorous Process Simulation Services for the Vegetable oils & Fats refining industry (Degumming - Neutralising Bleaching Deodorising/Physical Refining) Deodorising and Physical

More information

NARVIK-YARWAY. Heavy Duty A.T. - Temp Desuperheater Model: 18/54 and 28/64

NARVIK-YARWAY. Heavy Duty A.T. - Temp Desuperheater Model: 18/54 and 28/64 NARVIK-YARWAY Narvik-Yarway covers requirements for Desuperheaters, pneumatic actuators, strainers with a wide range of models, sizes and materials to satisfy all the specifications of the power-pulp &

More information

Building 65 Pellet Fired Steam Plant

Building 65 Pellet Fired Steam Plant Building 65 Pellet Fired Steam Plant Bar Harbor, ME By Norm Burdzel, PE Facilities Engineer, The Jackson Laboratory Tony Davis, PE Mechanical Engineer, Allied Engineering JAX Oil Load, 1.6M GPY 14000 12000

More information

Evacuating by sorption or thermal means F04B 37/00. Attention is drawn to the following places, which may be of interest for search:

Evacuating by sorption or thermal means F04B 37/00. Attention is drawn to the following places, which may be of interest for search: F04F PUMPING OF FLUID BY DIRECT CONTACT OF ANOTHER FLUID OR BY USING INERTIA OF FLUID TO BE PUMPED {(evacuating by sorption F04B)}; SIPHONS {(conveying materials in bulk by flows of gas, liquid of foam

More information

National Maritime Center

National Maritime Center U.S.C.G. Merchant Marine Exam (Sample Examination) Page 1 of 33 U.S.C.G. Merchant Marine Exam Illustrations: 16 Choose the best answer to the following Multiple Choice Questions. 1. Traditionally, which

More information

Model 133 Models 134 & 135 AURORA 130 SERIES SINGLE STAGE TURBINE TYPE PUMPS

Model 133 Models 134 & 135 AURORA 130 SERIES SINGLE STAGE TURBINE TYPE PUMPS Model Models 4 & AURORA 0 SERIES SINGLE STAGE TURBINE TYPE PUMPS WWW.AURORAPUMP.COM AURORA 0 SERIES Single Stage Turbine Type Pumps Capacities to 0 G.P.M. Heads to 700 Ft. Temperatures to F A Pioneer in

More information

MSB kw

MSB kw MSB_BIANCA_ENG 10-03-2004 23:36 Pagina 3 Cod. 2200772235-1M - 03/04 - ALKARIA Rotary Screw Compressor MSB 11-15 - 18-22 - 30 kw GB MSB_VOLTA_ENG 10-03-2004 23:39 Pagina 1 Rotary Screw Compressor MSB DRY

More information

Features Globe Valve 2-Way & 3-Way Assembly Features:

Features Globe Valve 2-Way & 3-Way Assembly Features: Rev: 10/22/13 Features Globe Valve 2-Way & 3-Way Assembly Features: DG Series Automated Applications for Building Automation, Temperature Controls, HVAC Two-Way and Three-Way Assemblies Chilled Water Hot

More information

Pressure operated water valve Type WVFX and WVS

Pressure operated water valve Type WVFX and WVS Data sheet Pressure operated water valve WVFX and WVS Pressure operated water valves types WVFX and WVS are used for regulating the flow of water in refrigeration plants with water-cooled condensers. The

More information

Si Engineering GREAT Solutions. Process and steam safety valves to PED and DIN/EN standards

Si Engineering GREAT Solutions. Process and steam safety valves to PED and DIN/EN standards Engineering GREAT Solutions Process and steam safety valves to PED and DIN/EN standards Si 4302 Features Engineered with high discharge The state-of-the-art IMI Bopp & Reuther medium-pressure safety valve:

More information