Emissions Characteristics of Volatile and Semi-volatile Organic Compounds and Polynuclear Aromatic Hydrocarbons (PAHs) from Hot and Warm Mix Asphalts
|
|
- Ursula Nash
- 6 years ago
- Views:
Transcription
1 1/10 Emissions Characteristics of Volatile and Semi-volatile Organic Compounds and Polynuclear Aromatic Hydrocarbons (PAHs) from Hot and Warm Mix Asphalts Frank Farshidi, University of California, Davis, U.S.A. Isabel Faria, University of California, Davis, U.S.A. Peter G. Green, University of California, Davis, U.S.A. David Jones, University of California, Davis, U.S.A. John Harvey, University of California, Davis, U.S.A. ABSTRACT: Warm mix asphalt (WMA) technologies are now available to reduce the production temperatures of hot mix asphalt (HMA) and rubberized hot mix asphalt (R-HMA) by between 15 C and 55 C (59 F and 131 F). This study evaluates the qualitative and quantitative characteristics of emissions from HMA, R-HMA, and rubberized warm mix asphalt (R-WMA). Using a protocol developed previously by the University of California Pavement Research Center reactive organic gases (ROGs) and particulate matter (PM) were investigated. The ROGs consisted of several volatile organic compounds (VOCs) and semivolatile organic compounds (SVOCs) as well as polynuclear aromatic hydrocarbons (PAHs) both in solid and gaseous phase. Sample emissions were collected at several asphalt plants Emissions from each material were captured in charcoal tubes for VOCs and SVOCs according to NIOSH and XAD-2 tubes and filters for PAHs according to NIOSH The effects of material type and temperature on the emissions are investigated and compared. The results indicated that both the mix type and temperature significantly influence the emissions characteristics. Monitoring emissions kinetics over time illustrated that the majority of emissions are volatilized in the first hour after sampling initiation. The method developed in this study is suitable for characterizing emissions in future studies as a reliable and sensitive procedure for accurately quantifying asphalt fumes emissions. 1. Introduction As part of the second phase of the emissions study with WMA technologies, four different asphalt mixes at two different asphalt plants were sampled in the field using the methodology described previously [1]. Besides characterizing the VOCs and SVOCs in asphalt fumes, the second phase of this study also included characterization of PAH compounds from field samples during construction with both HMA and WMA mixes. The PAH chemicals constitute a diverse class of organic molecules and represent components with a wide range of molecular size and structural types [2]. A major health concern from asphalt fumes and PAHs is the potential exposure to carcinogens [3]. Factors such as the temperature and the source of the crude can lead to variations in composition and toxicity of the fumes [4, 5]. Information regarding the asphalt emissions and the effect of WMA technologies on emissions are still limited. Assessing potential exposure and quantifying VOCs, SVOCs and the PAHs in fumes are essentially problematic due to the lack of a methodology to evaluate such a complex mixture. Therefore, one of the major objectives of the second phase of this study was to develop and validate a reliable analytical method for identification and quantification of compounds in this complex mixture. Moreover, understanding the emissions
2 2/10 kinetics over time is investigated for asphalt plants. various mixes immediately after production at the 2. Experimental Details The second phase of the emissions study included measuring emissions at two different asphalt plants for collecting emissions data from four different mix types for two hours. Field sampling was conducted using the flux chamber discussed previously. Figure 1 illustrates the sampling train used in this study. As shown, the first branch includes a charcoal tube for collecting VOCs and SVOCs at a flow rate of 1.5 L/min for two hours. The second branch is also a charcoal trap at a flow rate of 1.5 L/min. The charcoal tubes at the second branch train are replaced every 30 minutes to understand the kinetics of the emission with time. The third sampling branch employs sampling through a PTFE filter (0.45- followed by an XAD-2 tube for capturing both the particulate and gaseous phase of the PAHs. The fourth and fifth sampling branches consist of XAD-2 trap and PTFE filter respectively as replicates and a check for the verification of the technique. Chamber Pump Charcoal Trap Charcoal Trap PTFE Filter XAD-2 Trap PTFE Filter XAD-2 Trap Figure 1: Diagram of the sampling train for fume collection 2.1 Mix Types Two different asphalt plants in the northern California region were selected for conducting the second phase of sampling. The sampling was conducted on a designated area next to the load-out area of the asphalt plants. Table 1 summarizes the mix properties used for collecting the emissions samples.
3 3/10 Table 1: Mix Properties during the Second Phase Emissions Sampling Parameter Plant#1 Plant#1 Plant#2 Plant#2 Mix Type 3/4" HMA with 15% RAP 1/2" R-HMA- OGFC 3/4" HMA 3/4" HMA Binder Type PG64-16 PG64-16 PG64-16 PG64-16 Binder Content 5.10% 6.50% 5.50% 4.70% WMA Technology - Advera - Evotherm Load-out Temperature ( C/ F) 160/(320) 147/(297) 150/(302) 123/(253) 2.2 Materials and Instruments Reagents dichloromethane and hexane were acquired from Aldrich (Milwaukee, WI). The PAH standard was purchased from Supelco. XAD-2 tubes [treated with 2- (hydroxymethyl)piperidine] and Poly (tetrafluoroethylene) (PTFE) filters (37 mm, pore size) were purchased from SKC Inc. Extraction of asphalt fumes from tubes and filters were performed by ultrasonic extraction. Individual sections of the charcoal tubes were extracted in separate vials using 1.5 ml of carbon disulfide as solvent and 30 minutes of sonication. The PTFE filters and the XAD-2 resin were extracted separately with 5 ml of dichloromethane/hexane (1:1). Ultrasonic extraction was performed for 1 h for filter samples and 1.5 h for XAD-2 samples. 2.3 Sample Purification and Clean-up Asphalt fumes are extremely complex and consist of aliphatic, heterocyclic compounds, polycyclic aromatic hydrocarbons (PAHs) and some nitrogen, oxygen, and sulfur containing compounds. In order to identify and characterize PAH compounds more accurately, a simplified purification method was developed and conducted. In this technique, a column (250mm x 10 mm i.d.) packed with silica cartridge was used to separate the PAHs from saturated and polar compounds. The solvent was dichlromethane/hexane (1:1). The extracts were filtered and preconcentrated by evaporating the solvent under a nitrogen blanket. 2.4 GC/MS Detection for Alkanes The determination of asphalt fume composition was carried out using Electron Impact Ionization (EI) of GC/MS. The high sensitivity of EI was used to quantify the asphalt fume samples. The GC/MS instrument was calibrated by an alkane standard containing 23 n- hydrocarbons (C6 thru C28). An Agilent series gas chromatograph coupled with a mass spectrometer (Agilent, 5973N) was used. The gas chromatograph, equipped with a 30-5 capillary column, provided satisfactory separation of various compounds. The helium carrier gas was introduced at a rate of 1.0 ml/min) and linear velocity of 20 cm/s. The initial column temperature was maintained at 50 C for 4 minutes, then raised to 125 C at a rate of 2 C/min, and finally to 280 C at a rate of 10 C/min. The extraction efficiencies from activated charcoal tubes are presented in Table 5-2. The table provides information regarding the detection limits as well as the accuracy for the
4 4/10 alkane compounds. Full scan mode with splitless injection was used as the spectrometric technique for characterizing VOCs and SVOCs. A purge time of 1.5 minute was specified in the method. After the purge time, the splitter vent is opened to purge solvent from the injector. Splitless injection, therefore, concentrates the sample and purges most of the volatile solvent [5]. For this reason, and because of the large amounts of sample that can be injected, splitless injection was used for this study. Table 2: Retention Time, Detection Limit, and Extraction Efficiencies for the GC/MS Analysis of VOCs and SVOCs Compound Retention Time Detection Limit (ng/m 3 ) Recovery from charcoal tubes (%) Decane Undecane Dodecane Tridecane Tetradecane Pentadecane Hexadecane Heptadecane Octadecane GC/MS Detection for PAHs To detect individual priority PAHs in asphalt fumes at trace levels, a selected ion monitoring (SIM) mass spectrometer was used. In the SIM mode of operation, the detection system was dedicated to monitoring only a few ion currents. In this mode, the mass spectrometer does not spend time scanning the entire mass range, but rapidly changes between m/z values for which characteristic ions are expected [6]. Therefore, the sensitivity was tremendously higher than the scanning mode. A mixture of 16 priority standard PAHs was used for calibration. The initial column temperature was maintained at 100 C for 2 minutes, then raised to 300 C at a rate of 2 C/min. Splitless injection with 1.5 mins purge time was used. The carrier gas helium and a solvent delay of 5 mins were used in the method. To evaluate the recovery of the sample, stable isotope dilution with perdeuterited anthracene as an internal standard was used. The relative recovery of the internal standard can account for losses of the analytes during sample preparation and detection processes. This procedure improved the reliability of the analysis. In these experiments, perdeuterited anthracene was added to the sample at a concentration of 10 ng/l. The recoveries of spiked PAHs from XAD-2 tubes are shown in Table 5-3. Table 5-3 also illustrates the major ions that were monitored in the SIM mode for all the sixteen PAH compounds. Table 3: Retention Time, Recovery, and Major Ion for Priority PAHs Compound Retention Time(min) Recovery from XAD-2 resin (%) Major Ions to be Monitored
5 5/10 Naphthalene , 102, 64 Acenaphthylene , 76, 63 Acenaphthene , 154 Fluorene , 139, 83 Phenanthrene , 89, 76 Anthracene , 89, 76 Fluoranthene , 101, 88 Pyrene , 101, 89 Benz(a)anthracene , 114, 101 Chrysene , 114, 102 Benzo(b)fluoranthene , 126, 113 Benzo(k)fluoranthene , 126, 114 Benzo(a)pyrene , 138, 124 Dibenz(a,h)anthracene , 138, 124 Benzo(ghi)perylene , 139, 125 Indeno(1,2,3-cd)pyrene , 138, Results and Discussion 3.1 Emissions of Alkanes The emissions of total alkanes and individual alkanes from the four different mixes collected on activated charcoal tubes are shown in Figure 2 and Figure 3 respectively. It can be observed from Figure 5-2 that the emissions of the mixes without any WMA technologies that had higher temperature at time of the sampling are significantly higher than the mixes with WMA technologies and lower temperatures. The emissions of alkanes as a function of sampling time are presented in Figure 4. The results show that the emissions decreased as time progressed. During the first thirty minutes of sampling, alkane emissions were present in higher concentrations for all the mixes and specially the mixes without WMA technologies. The second thirty minutes produced lower concentrations of alkanes. The emissions in the third and fourth time interval were significantly lower. These results demonstrate that most of the alkane emissions volatilize from the mix during the first hour of sampling and as time progresses the emissions are reduced significantly.
6 6/10 Alkane Emission Concentration (µg/m 3 ) 3,000 2,500 2,000 1,500 1, Alkane Emissions Temperature Mix Temperature ( C) Figure 2: Total alkane emissions concentration for four different mixes 450 Alkane Emissions HMA with 15% RAP Alkane Emission Concentration (µg/m 3 ) R-WMA with Advera WMA with Evotherm HMA 0 Figure 3: Alkane emissions concentrations for four different mixes
7 7/10 Figure 4: Alkane emissions versus time for four different mixes 3.2 Emissions of PAHs Emissions of PAHs for all the four mixes are presented in Figure 5. It must be noted that the PAHs are distributed between gaseous and particulate phase. Results in Figure 5 are the concentrations of PAHs collected on XAD-2 tubes (gaseous). It can be observed from this figure that PAH concentrations were significantly decreased as the temperature of the mix was decreased. Results indicate that temperature is an important parameter that influences the PAH emissions. By using WMA technologies to reduce mix temperatures, significant reduction of PAHs is observed. Moreover, in the temperature range for the mixes in this study, the PAH concentrations are only observed at trace levels both for the control and WMA mixes. The particulate phase emissions collected on filters had concentrations below the detection level of the analytical method. The same trend was observed on both the sampling branch in series with the XAD-2 tube and the branch with the filter only. Detailed sample clean-up and SIM method of analyzing ensured the detection of the compounds at ultratrace levels. The Limit of Detection (LOD) and Limit of Quantification (LOQ) were determined as respectively 3 times and 10 times the standard deviation of seven replicates of a low concentration standard. Table 4 lists the LOD and LOQ for all the PAH compounds analyzed. As illustrated in this table, LOD ranged from to ng/ul (or 2-7 ug/l) while LOQ ranged from to 0.02 ng/ul (5-20 ug/l).
8 8/10 Table 4: LOD and LOQ for the PAH Compounds PAH Compound LOD (ng/ul) LOQ (ng/ul) Naphthalene Acenaphthylene Acenaphthene Fluorene Phenanthrene Anthracene Fluoranthene Pyrene Chrysene Benzo(a)anthracene Benzo(b)fluoranthene Benzo(k)fluoranthene Benzo(a)pyrene Indeno(1,2,3-cd)pyrene Dibenzo(a,h)anthracene Benzo(ghi)perylene PAH Emissions 100 PAH Emission Concentration (µg/m 3 ) HMA with 15% RAP R-WMA with Advera HMA WMA with Evotherm 0 Figure 5: Concentration of various PAHs from four different mixes sampled at asphalt plants
9 9/10 4. Summary and Conclusions The purpose of this study was to understand the emissions kinetics of VOCs and SVOCs over time using the field sampling methodology developed previously and identify/quantify the PAH compounds in asphalt fumes. A sensitive and selective method for identification and characterization of VOCs, SVOCs, and PAHs was developed and verified for various mixes at the asphalt plants. The alkane emissions consisted of n-hydrocarbons ranging from C8 to C18 range. Depending on the mix and the temperature of the mix at the time of sampling, the total alkane emissions ranged from 117 µg/m3 (WMA with evotherm technology) to 2516 µg/m3 for conventional HMA. The kinetic of emissions over time indicated that the majority of alkane emissions are volatilized in the first hour after the sampling initiation. The gaseous phase PAH emissions mainly consisted of low molecular weight PAH compounds and mixes with higher initial production temperatures showed higher PAH concentrations. Both SIM and full mode GC-MS analysis confirmed that the particulate phase of PAHs are present at ultertrace levels and were below the detection limit of used in this study. Limit of detection ranged from to ng/ul (or 2-7 ug/l) while limit of quantification ranged from to 0.02 ng/ul (5-20 ug/l) the mixes at time of sampling ranged from 123 C to maximum of 160 C. The results confirmed that this temperature range is not high enough to initiate significant PAH formation in asphalt emissions. PAH compounds are mainly formed when there is combustion and for asphalt binders that requires temperatures above 500 C. Moreover, depending on the source of the binder and the manufacturing process of the crude oil, many of the lower molecular weight PAH compounds might have been removed during the refinery process. More research is needed to quantify emissions from different mixes at different temperatures, mainly in the range of WMA and R-WMA production temperatures. Simulating asphalt fumes in the laboratory conditions will aid in identifying and characterizing emissions kinetics of different WMA technologies, production temperatures, and binder sources. Determining the optimal temperature range that will minimize the emissions concentrations without undermining performance properties need to be investigated in future studies. 5. References 1. Farshidi, F., Jones, D., Kumar, A., Green, P. and Harvey, J., Direct Measurements of Volatile and Semivolatile Organic Compounds from Hot and Warm Mix Asphalt. Transportation Research Record, Grosjean, D., Polycyclic Aromatic-Hydrocarbons in Los-Angeles Air from Samples Collected on Teflon, Glass and Quartz Filters. Atmospheric Environment, (12): p Vu-Duc, T., C.K. Huynh, and S. Binet, Laboratory generated bitumen fumes under standardized conditions. Clean-up scheme and ion trap GC-MS analysis of VOC, semi-volatile and particulate PAH and PASH. Journal of Occupational and Environmental Hygiene, : p Fernandes, P.R.N., et al., Evaluation of Polycyclic Aromatic Hydrocarbons in Asphalt Binder Using Matrix Solid-Phase Dispersion and Gas Chromatography. Journal of Chromatographic Science, (9): p
10 10/10 5. Wang, J., et al., Characterization of asphalt fume composition under simulated road paving conditions by GC/MS and microflow LC/quadrupole time-of-flight MS. Analytical Chemistry, (15): p Lange, C.R. and M. Stroup-Gardiner, Temperature-dependent chemical-specific emission rates of aromatics and polyaromatic hydrocarbons (PAHs) in bitumen fume. Journal of Occupational and Environmental Hygiene, : p
Complete Fractionation of Extractable Petroleum Hydrocarbons Using Newly Developed EPH SPE Cartridges
Complete Fractionation of Extractable Petroleum Hydrocarbons Using Newly Developed EPH SPE Cartridges Alexandria Pavkovich Jason Thomas Trent Sprenkle Outline Background EPA Method Requirements Background
More informationLarge Volume Injection of Polycyclic Aromatic Hydrocarbons
JSB is an authorised partner of Large Volume Injection of Polycyclic Aromatic Hydrocarbons Application Note - Environmental #113 Author Anne Jurek Applications Chemist EST Analytical Cincinnati, OH Abstract
More informationCONSTITUTION OF COAL TAR PITCH AND ITS EFFECT ON PROPERTIES
CONSTITUTION OF COAL TAR PITCH AND ITS EFFECT ON PROPERTIES H. K. Mayer 1 and I. C. Lewis 2 1 GrafTech International Ltd., 12900 Snow Road, Parma, OH 44130 2 Consultant Introduction Corresponding author
More informationAPPLICATION OF SOLID PHASE MICROEXTRACTION (SPME) IN PROFILING HYDROCARBONS IN OIL SPILL CASES
APPLICATION OF SOLID PHASE MICROEXTRACTION (SPME) IN PROFILING HYDROCARBONS IN OIL SPILL CASES Zuraidah Abdullah Munir*, Nor ashikin Saim, Nurul Huda Mamat Ghani Department of Chemistry, Faculty of Applied
More informationMethod-Specific Sample Preparation for EPH Analysis
Method-Specific Sample Preparation for EPH Analysis Resprep SPE Cartridges for Complete Extractable Petroleum Hydrocarbon Fractionation Full separation between fractions. Guaranteed low background level.
More informationProof of Long-Term, Leak-Free Performance for a Novel Self-tightening GC Column Nut
Proof of Long-Term, Leak-Free Performance for a Novel Self-tightening GC Column Nut Application Note Environmental Author Ken Lynam Agilent Technologies, Inc. Abstract Specially designed self-tightening
More informationDetermination of PAH Compounds from Aqueous Samples Using a Non-Halogenated Extraction Solvent and Atlantic C18 Disks
Determination of PAH Compounds from Aqueous Samples Using a Non-Halogenated Extraction Jim Fenster, Kevin Dinnean,, David Gallagher, Michael Ebitson, Horizon Technology, Inc., Salem, NH Introduction Polycyclic
More informationApplication Note. Abstract. Authors. Environmental Analysis
High Throughput Mineral Oil Analysis (Hydrocarbon Oil Index) by GC-FID using the Agilent Low Thermal Mass (LTM II) System Application Note Environmental Analysis Authors Frank David and Karine Jacq Research
More informationHigh Throughput Mineral Oil Analysis (Hydrocarbon Oil Index) by GC-FID Using the Agilent Low Thermal Mass (LTM) System
High Throughput Mineral Oil Analysis (Hydrocarbon Oil Index) by GC-FID Using the Agilent Low Thermal Mass (LTM) System Application Note Authors Frank David Research Institute for Chromatography, Pres.
More informationGC/MS Analysis of Trace Fatty Acid Methyl Esters (FAME) in Jet Fuel Using Energy Institute Method IP585
GC/MS Analysis of Trace Fatty Acid Methyl Esters (FAME) in Jet Fuel Using Energy Institute Method IP585 Application Note Fuels Author James D. McCurry, Ph.D. Agilent Technologies, Inc. 850 Centerville
More informationGas Chromatographic Analysis of Diesel Fuel Dilution for In-Service Motor Oil Using ASTM Method D7593
Application Note Gas Chromatographic Analysis of Diesel Fuel Dilution for In-Service Motor Oil Using ASTM Method D7593 Authors Kelly Beard and James McCurry Agilent Technologies, Inc. Abstract An Agilent
More informationSupporting Information for. Diesel Particle Filter and Fuel Effects on Heavy-Duty Diesel Engine Emissions
Supporting Information for Diesel Particle Filter and Fuel Effects on Heavy-Duty Diesel Engine Emissions Matthew Ratcliff, A. John Dane, Aaron Williams, John Ireland, Jon Luecke, Robert L. McCormick, and
More informationAnalysis of Petroleum Fractions by ASTM D2887
Analysis of Petroleum Fractions by ASTM D2887 Peter Morgan, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 2582 Key Words Simulated distillation, D2887, TRACE TR-SimDist Abstract ASTM
More informationDetection of Sulfur Compounds in Natural Gas According to ASTM D5504 with an Agilent Dual Plasma Sulfur Chemiluminescence Detector
Detection of Sulfur Compounds in Natural Gas According to ASTM D554 with an Agilent Dual Plasma Sulfur Chemiluminescence Detector Application Note Author Rebecca Veeneman Abstract Sulfur compounds in natural
More informationDetection of Volatile Organic Compounds in Gasoline and Diesel Using the znose Edward J. Staples, Electronic Sensor Technology
Detection of Volatile Organic Compounds in Gasoline and Diesel Using the znose Edward J. Staples, Electronic Sensor Technology Electronic Noses An electronic nose produces a recognizable response based
More informationNew Integrated GC Guard Columns for Built-In Protection
New Integrated GC Guard Columns for Built-In Protection GUARDIAN: Quick and Easy to Set-up With Guardian you get your column plus 5 or 10 meters of additional integrated deactivated tubing. However, it
More informationTEKLAB, INC ANALYTICAL QC SUMMARY REPORT. CLIENT: Kelron Environmental Work Order: Project: CHMGP/ Page 1 of 6.
TEKLAB, INC CLIENT: Kelron Environmental Date: 27-Dec-6 Sample ID: MB-3498 SampType: MBLK SeqNo: 145961 Acenaphthene ND.1 Acenaphthylene ND.1 Anthracene ND.1 Benzo(a)anthracene ND.1 Benzo(a)pyrene ND.1
More informationMethod Development for Capillary GC Systems. Slide 1
Method Development for Capillary GC Systems Slide 1 AREAS TO OPTIMIZE Injector Carrier gas Column temperature Slide 2 COMMON INJECTOR MODES Vaporization Injection Modes Megabore Direct Split Splitless
More informationState of Texas UST Monitoring visit us online at The latest TNRCC 1005/1006 UST methods used by Texas.
At-a-Glance Product Information from Restek State of Texas UST Monitoring To help laboratories comply with and use these analytical procedures, Restek has been active in following the state guidance. Based
More informationApplication Note. Authors. Abstract. Energy & Chemicals
Determination of Aromatic Content in Diesel Fuel According to ASTM D5186 Enhancing the Agilent 126 Infi nity Analytical SFC System with a Flame Ionization Detector Application Note Energy & Chemicals Authors
More informationASTM D2887 Simulated Distillation Calibration Mixture Analysis Using a Differential Acceleration Column
ASTM D2887 Simulated Distillation Calibration Mixture Analysis Using a Differential Acceleration Column Cory S. Fix, Director of Application Development cory.fix@vgcchromatography.com Willie Steinecker,
More informationBeverage Grade Carbon Dioxide
Analysis by Gas Chromatography Engineered Solutions, Guaranteed Results. WASSON - ECE INSTRUMENTATION The Challenge Carbon dioxide, used in the production of carbonated soft drinks and other beverages,
More informationPAH and Nitro-PAH emissions from GDI vehicles
19 th ETH-Conference on Combustion Generated Nanoparticles June 28 th July 1 st, 2015 ETH Zürich, Switzerland PAH and Nitro-PAH emissions from GDI vehicles Dr. Maria Muñoz Fernandez Coauthors: Dr. Norbert
More informationCharacterization and Source Identification of an Unknown Spilled Oil Using Fingerprinting Techniques by GC MS and GC FID
15 LCGC VOLUME 1 NUMBER 1 OCTOBER 2 www.chromatographyonline.com Characterization and Source Identification of an Unknown Spilled Oil Using Fingerprinting Techniques by GC MS and GC FID This article describes
More informationAppendix A.1 Calculations of Engine Exhaust Gas Composition...9
Foreword...xi Acknowledgments...xiii Introduction... xv Chapter 1 Engine Emissions...1 1.1 Characteristics of Engine Exhaust Gas...1 1.1.1 Major Components of Engine Exhaust Gas...1 1.1.2 Units Used for
More informationRegulated and Unregulated Exhaust Emissions Comparison for Three Tier II Non-Road Diesel Engines Operating on Ethanol- Diesel Blends
NREL/CP-540-38493. Posted with permission. Presented at the 2005 SAE Brasil Fuels & Lubricants Meeting, May 2005, Rio de Janiero, Brazil 2005-01-2193 Regulated and Unregulated Exhaust Emissions Comparison
More informationIncreased sensitivity and reproducibility in the analysis of trace fatty acid methyl esters in jet fuel
Application Note Energy and Chemicals Increased sensitivity and reproducibility in the analysis of trace fatty acid methyl esters in jet fuel Applying the Energy Institute Method IP 8 with an Agilent J&W
More informationLiquefied Gas Injector. Solution for the Sampling and Analysis of Liquefied Gases
Liquefied Gas Injector Solution for the Sampling and Analysis of Liquefied Gases Safe and Representative Sampling of Liquefied Gases The analysis of impurities and contaminants in liquefied gases is an
More informationApplicant: GUANGDONG XIN YU TECHNOLOGY INDUSTRIAL Date: Mar 21, 2018 CO.,LTD. LAI MEI INDUSTRIAL ZONE, CHENGHAI DISTRICT, SHAN TOU, GUANGDONG, CHINA
Applicant: GUANGDONG XIN YU TECHNOLOGY INDUSTRIAL Date: Mar, 08 CO.,LTD. LAI MEI INDUSTRIAL ZONE, CHENGHAI DISTRICT, SHAN TOU, GUANGDONG, CHINA Attn: MS LIN Sample Description: Thirteen () styles of submitted
More informationSetting up SilFlow for BackFlush in your GC
Setting up SilFlow for BackFlush in your GC What is backflush and why use it? The BackFlush system eliminates the need to bake heavy sample fractions off the capillary column. Oils, tars and other semivolatile
More informationCharacterization of Tiki Torch Fuels
1940 N. Stark Road Midland, MI 48642 USA Phone: 855-IA-SOLVE (855-427-6583) Fax: (989) 486-9429 www.impactanalytical.com Customer: Philip Tyson Report Number*: R140075 Company: The Coconut Group Date Submitted:
More informationINTEREST OF HPTLC FOR FOSSIL DERIVED PRODUCTS ANALYSIS : A SIMPLE APPROACH TO HYDROCARBON GROUP TYPE ANALYSIS
INTEREST OF HPTLC FOR FOSSIL DERIVED PRODUCTS ANALYSIS : A SIMPLE APPROACH TO HYDROCARBON GROUP TYPE ANALYSIS Muriel Matt 1,2, Vicente L. Cebolla 1, Luis Membrado 1, Eva M. Galvez 1, Jesus Vela 1, Robert
More informationAchieving Higher Sensitivities Using GC-FID with the Agilent Multimode Inlet (MMI)
Achieving Higher Sensitivities Using GC-FID with the Agilent Multimode Inlet (MMI) Application Note All Industries Authors Brian Fitz and Bill Wilson Agilent Technologies, Inc. 285 Centerville Road Wilmington,
More informationHigh Sensitivity UHPLC-DAD Analysis of Azo Dyes using the Agilent 1290 Infinity LC System and the 60 mm Max-Light High Sensitivity Flow Cell
High Sensitivity UHPLC-DAD Analysis of Azo Dyes using the Agilent 1290 Infinity LC System and the 60 mm Max-Light High Sensitivity Flow Cell Application Note Consumer Products Authors Gerd Vanhoenacker,
More informationevaluation of automotive polycyclic aromatic hydrocarbon emissions
evaluation of automotive polycyclic aromatic hydrocarbon emissions Prepared for the CONCAWE Automotive Emissions Management Group by its Special Task Force FE/STF-12: R. Doel R. Jørgensen L.C. Lilley N.
More informationTest Report. Final conclusion: PASS SHA18. Gohandmade Dsign International A/S HANNE Madevej Aabenraa DENMARK
Gohandmade Dsign International A/S HANNE Madevej 11-13 6200 Aabenraa DENMARK Date of order: 14.06.18 Contact: Penny Guo Direct dial: +86(21) 60725688 x 5659 Email: penny.guo@hansecontrol.com Test Report
More informationUsing a New Gas Phase Micro-Fluidic Deans Switch for the 2-D GC Analysis of Trace Methanol in Crude Oil by ASTM Method D7059 Application
Using a New Gas Phase Micro-Fluidic Deans Switch for the 2-D GC Analysis of Trace Methanol in Crude Oil by ASTM Method D759 Application Petrochemical Author James D. McCurry Agilent Technologies 285 Centerville
More informationLight and Middle Distillate Environmental Forensics. Wenhui Xiong, Ryan Bernesky, Robert Bechard, Guy Michaud, Jeremy Lang
Light and Middle Distillate Environmental Forensics Wenhui Xiong, Ryan Bernesky, Robert Bechard, Guy Michaud, Jeremy Lang October 15, 2015 Outline 1 Introduction 2 Site Characterization and Sample Collection
More informationUsing the PSD for Backflushing on the Agilent 8890 GC System
Application Note Petrochemicals Using the PSD for Backflushing on the Agilent 889 GC System Author Brian Fitz Agilent Technologies, Inc. Wilmington, DE, USA. Abstract An Agilent 889 series GC equipped
More informationA new method for assessing worker exposure to diesel-based drilling fluids.
A new method for assessing worker exposure to diesel-based drilling fluids. Michael Breitenstein John Snawder Disclaimer: The findings and conclusions in this presentation are those of the authors and
More informationDIFFERENTIATION OF CRUDE OILS, FUEL OILS, AND USED LUBRICATING OIL USING DIAGNOSTIC RATIOS
DIFFERENTIATION OF CRUDE OILS, FUEL OILS, AND USED LUBRICATING OIL USING DIAGNOSTIC RATIOS Pornpetch Hattakijvilai a, Siriporn Jongpatiwut*,a,b a The Petroleum and Petrochemical College, Chulalongkorn
More informationGroup-Type Analysis (PiPNA) in Diesel and Jet Fuel by Flow Modulated GCxGC FID.
Group-Type Analysis (PiPNA) in Diesel and Jet Fuel by Flow Modulated GCxGC FID. Dedicated PiPNA + FAME For (Bio-)Diesel and Jet Fuels Robust System, Easy to use No Cryogenic coolant Required Keywords:
More informationFast and Reliable Trace Gas Analysis Improved Detection Limits for the Agilent 490 Micro GC
Fast and Reliable Trace Gas Analysis Improved Detection Limits for the Agilent 490 Micro GC Technical Overview Trace gas analysis is a challenge in today s world. The ability to analyze lower component
More informationState of Alaska UST Monitoring
Contact Information At-a-Glance Product Information from Restek Alaska Department of Environmental Conservation 410 Willoughby Avenue Juneau, AK 99801-1795 Phone: (907) 465-5203 Fax: (907) 465 5218 www.state.ak.us/dec/deh/laboratories/ust.htm
More informationApplication. Gas Chromatography June 1995
Determining Oxygenates in Gasoline: ASTM Method D Application Gas Chromatography June 99 Authors Michael J. Szelewski Agilent Technologies, Inc. 0 Centerville Road Wilmington, DE 90-60 USA Matthew S. Klee
More informationHeavy Fuel Oil 6303 (2002)
Origin Imperial Oil Ltd., Nova Scotia, Canada (2002) Synonyms: Bunker C, Land Bunker API Gravity 11.47 (calc) Equation for Predicting Evaporation %Ev = ( -0.16 + 0.013 T) t 1/2 Where: %Ev = weight percent
More informationHydrocarbons. Land Based Gas Turbines Emissions Regulations and Measurement Methods
Land Based Gas Turbines Emissions Regulations and Measurement Methods Hydrocarbons Laura Platt University of Sheffield E-Futures DTC Email: dtp09lcp@sheffield.ac.uk Overview Gas Turbines Atmospheric Hydrocarbon
More informationOn-Road Emission Rates of PAH and n-alkane Compounds from Heavy-Duty Diesel Vehicles
Environ. Sci. Technol. 2005, 39, 5276-5284 On-Road Emission Rates of PAH and n-alkane Compounds from Heavy-Duty Diesel Vehicles SANDIP D. SHAH,, TEMITOPE A. OGUNYOKU,, J. WAYNE MILLER, AND DAVID R. COCKER
More informationEvaluation of Total Petroleum Hydrocarbon in Soil Using LC with Fraction Collector and GC/MS
Evaluation of Total Petroleum Hydrocarbon in Soil Using LC with Fraction Collector and GC/MS Application Environmental Authors Wei Luan and Chuanhong Tu Agilent Technologies (Shanghai) Co., Ltd. 412 Ying
More informationGAS CHROMATOGRAPHY: INJECTION TECHNIQUES CAPILLARY COLUMNS
GAS CHROMATOGRAPHY: INJECTION TECHNIQUES CAPILLARY COLUMNS FLASH VAPORISATION INJECTION Split Splitless On-Column COOL INJECTION Large Volume Injection (LVI) On-Column On-Column-SVE (with solvent vapour
More informationQuantification and Characterization of Sulfur in Low-Sulfur Reformulated Gasolines by GC-ICP-MS Application
Quantification and Characterization of Sulfur in Low-Sulfur Reformulated Gasolines by GC-ICP-MS Application Authors Steven M. Wilbur and Emmett Soffey Agilent Technologies 338 146th Place SE Bellevue,
More informationImpurity Testing of Fixed-Dose Combination Drugs Using the Agilent 1290 Infinity II HDR-DAD Impurity Analyzer Solution
Impurity Testing of Fixed-Dose Combination Drugs Using the Agilent 129 Infinity II HDR-DAD Impurity Analyzer Solution Application ote Small Molecule Pharmaceuticals Author Sonja Schneider Agilent Technologies,
More informationJournal of Environmental Monitoring
PAPER www.rsc.org/jem Journal of Environmental Monitoring Comparison of pressurized fluid extraction, Soxhlet extraction and sonication for the determination of polycyclic aromatic hydrocarbons in urban
More informationSPECIFICATION. Bench top triple quadrupole Mass Spectrometry System coupled to a gas performance Chromatography (GC-MS/MS)
SPECIFICATION Bench top triple quadrupole Mass performance Chromatography (GC-MS/MS) 1. Scope These specifications describe the requirements for a bench top triple quadrupole mass spectrometry system coupled
More informationTechnical Procedure for Gas Chromatography (GC-FID)
Technical Procedure for Gas Chromatography (GC-FID) 1.0 Purpose This technical procedure shall be followed for the operation of the gas chromatograph (GC- FID). 2.0 Scope This procedure applies to all
More informationThe Analysis of Hydrocarbon Composition in LPG by Gas Chromatography using the DVLS Liquefied Gas Injector
Authors: The Analysis of Hydrocarbon Composition in LPG by Gas Chromatography using the DVLS Liquefied Gas Injector Introduction Specification of the hydrocarbon composition of LPG is required as traces
More informationSimultaneous Determination of Fatty Acid Methyl Esters Contents in the Biodiesel by HPLC-DAD Method
2016 International Conference on Applied Mechanics, Mechanical and Materials Engineering (AMMME 2016) ISBN: 978-1-60595-409-7 Simultaneous Determination of Fatty Acid Methyl Esters Contents in the Biodiesel
More informationHigh Temperature Simulated Distillation Performance Using the Agilent 8890 Gas Chromatograph
Application Note Petrochemicas High Temperature Simulated Distillation Performance Using the Agilent 8890 Gas Chromatograph Author James D. McCurry, Ph.D. Agilent Technologies, Inc. Abstract An Agilent
More informationAppNote 6/2006. Ultra-Fast Determination of the Hydrocarbon Oil Index by Gas Chromatography using a Modular Accelerated Column Heater (MACH) KEYWORDS
AppNote 6/26 Ultra-Fast Determination of the Hydrocarbon Oil Index by Gas Chromatography using a Modular Accelerated Column Heater (MACH) Andreas Hoffmann GERSTEL GmbH & Co.KG, Eberhard-Gerstel-Platz 1,
More informationAlternative Carrier Gases for ASTM D7213 Simulated Distillation Analysis
Introduction Petroleum & Petrochemical Alternative Carrier Gases for ASTM D7213 Simulated Distillation Analysis By Katarina Oden, Barry Burger, and Amanda Rigdon Crude oil consists of thousands of different
More informationTechnical Procedure for the Examination of Arson Evidence
Technical Procedure for the Examination of Arson Evidence 1.0 Purpose This technical procedure shall be followed for the examination of arson (fire debris) evidence. 2.0 Scope This procedure applies to
More informationWhite Paper. Improving Accuracy and Precision in Crude Oil Boiling Point Distribution Analysis. Introduction. Background Information
Improving Accuracy and Precision in Crude Oil Boiling Point Distribution Analysis. Abstract High Temperature Simulated Distillation (High Temp SIMDIS) is one of the most frequently used techniques to determine
More informationUnderground Storage Tanks Compliance Monitoring with Restek Analytical Reference Materials
Underground Storage Tanks Compliance Monitoring with Restek Analytical Reference Materials Fuel Composite Standards.............. 3 Single Source Fuel Standards......... 3 4 Fuel Surrogate Standards...............
More informationIndustrial Hygiene Strategies for Assessing Exposures During Onshore Drilling Activities
Industrial Hygiene Strategies for Assessing Exposures During Onshore Drilling Activities Bradley King, PhD, MPH, CIH NIOSH Western States Division Disclaimer: The findings and conclusions in this report
More informationMeeting the Requirements of EN12916:2006 (IP391/07) Using Agilent 1200 Series HPLC Systems
Meeting the Requirements of EN12916:2006 (IP391/07) Using Agilent 1200 Series HPLC Systems Application Note Hydrocarbons Authors Michael Woodman Agilent Technologies, Inc. Chemical Analysis Solutions 2850
More informationTechnical Procedure for Pyrolysis-Gas Chromatography/Mass Spectrometry (Py-GC-MS)
Technical Procedure for Pyrolysis-Gas Chromatography/Mass Spectrometry (Py-GC-MS) 1.0 Purpose This technical procedure shall be followed for the operation of the pyrolysis-gas chromatograph-mass spectrometer
More informationTechnical Procedure for Gas Chromatography-Mass Spectrometry (GC-MS)
Technical Procedure for Gas Chromatography-Mass Spectrometry (GC-MS) 1.0 Purpose This technical procedure shall be followed for the operation of the gas chromatograph-mass spectrometer (GC-MS). 2.0 Scope
More informationApplication Note. Determination of Oxygenates in C2, C3, C4 and C5 hydrocarbon Matrices according ASTM D using AC OXYTRACER
Determination of Oxygenates in C2, C3, C4 and C5 hydrocarbon Matrices according ASTM D7423-09 using AC OXYTRACER Fast Analysis in
More informationImproving NAPL Site Investigations using UVF and LIF Technologies Together Image courtesy of Dakota Technologies, Inc.
Improving NAPL Site Investigations using UVF and LIF Technologies Together Image courtesy of Dakota Technologies, Inc. Steve Greason, Speaker & Author Sitelab Corporation Technical Session: Life Cycle
More informationApproaches to quantify the biogenic interference on Petroleum hydrocarbon levels
Approaches to quantify the biogenic interference on Petroleum hydrocarbon levels Chris Swyngedouw Remtech 2007 Outline GC/FID hydrocarbon analysis Silica gel treatment Approaches to quantify the biogenic
More informationInvestigation of the Feasibility of Achieving Euro VI Heavy-Duty Diesel Emissions Limits by Advanced Emissions Controls
Investigation of the Feasibility of Achieving Euro VI Heavy-Duty Diesel Emissions Limits by Advanced Emissions Controls D Bosteels, J May AECC Association for Emissions Control by Catalyst, Belgium A J
More informationAnalysis of biodiesel oil (as per ASTM D6751 & EN 14214) using the Agilent 5100 SVDV ICP-OES
Analysis of biodiesel oil (as per ASTM D6751 & EN 14214) using the Agilent 5100 SVDV ICP-OES Application note Petrochemical Author Neli Drvodelic Agilent Technologies Melbourne, Australia Introduction
More information[ APPLICATION NOTE ] INTRODUCTION APPLICATION BENEFITS WATERS SOLUTIONS KEYWORDS
MS Identification of Trace level Impurities from a Non-MS Compatible Mobile Phase Using ACQUITY UPLC System with 2D Technology by Heart-cutting and Online Sample Concentration Bronsky Gopinadh, Dilshad
More informationAgilent Multimode Inlet for Gas Chromatography
Agilent Multimode Inlet for Gas Chromatography Technical Note Agilent Multimode Inlet for the 7890A GC Designed to give you ease of use and maximum flexibility, the Agilent Multimode Inlet does everything
More informationSELERITY TECHNOLOGIES SOLUTIONS FOR YOUR SUPERCRITICAL FLUID NEEDS
Rev 1 3/6/2004 Selerity Technologies Inc. www.selerity.com SELERITY TECHNOLOGIES SOLUTIONS FOR YOUR SUPERCRITICAL FLUID NEEDS What is supercritical fluid chromatography? A chromatographic technique in
More informationLarge Volume Injection (LVI) for GC:
Large Volume Injection (LVI) for GC: Do s; Don ts; Why s; Won ts Robert G. Brown NEMC August 4-8, 2014 Washington, D.C www.lancasterlabsenv..com Some (Recent) History October/November, 2003 Paolo Magni
More informationHydrocarbon Analysis using Sitelab UVF for DENR UST Program
Steve Greason, Instructor Sitelab Corporation West Newbury, MA (978) 363-2299 LSP Course No. 1203, 4 Edu Credits Westford Regency Inn, Westford, MA Tuesday, February, 2 nd 2016 1:00-5:00 PM Hydrocarbon
More informationSilica Gel Cleanup of Extractable Petroleum Hydrocarbons Do you know what you are removing?
Silica Gel Cleanup of Extractable Petroleum Hydrocarbons Do you know what you are removing? AGAT Labs AGAT Labs Spill Response and Mobile Lab Services Field and Laboratory Response Mobile Lab After Hours
More informationRapid Qualitative GC-TOFMS Analysis of a Petroleum Refinery Reformate Standard
Rapid Qualitative GC-TFMS Analysis of a Petroleum Refinery Reformate Standard LEC Corporation; Saint Joseph, Michigan USA Key Words: GC-TFMS, Petrochemical, Deconvolution 1. Introduction Analyses of petroleum
More informationModule8:Engine Fuels and Their Effects on Emissions Lecture 36:Hydrocarbon Fuels and Quality Requirements FUELS AND EFFECTS ON ENGINE EMISSIONS
FUELS AND EFFECTS ON ENGINE EMISSIONS The Lecture Contains: Transport Fuels and Quality Requirements Fuel Hydrocarbons and Other Components Paraffins Cycloparaffins Olefins Aromatics Alcohols and Ethers
More informationTest Report. Lindner Aktiengesellschaft. Product Emissions Test according to ASTM Access Floor. April 2004
Test Report Lindner Aktiengesellschaft Product Emissions Test according to ASTM 5116-97 Access Floor April 2004 Client: Lindner Aktiengesellschaft Produktmanagement Sparte Boden Bahnhofstrasse 29 D-94424
More informationOptimized Supercritical Fluid Chromatographic Instrumentation for the Analysis of Petroleum Fractions
Optimized Supercritical Fluid Chromatographic Instrumentation for the Analysis of Petroleum Fractions Bruce E. Richter*, Brian A. Jones, and Nathan L Porter Sensar/Larson-Davis, 1652 W. 820 N., Provo,
More informationAchieving Lower Detection Limits Easily with the Agilent Multimode Inlet (MMI)
Achieving Lower Detection Limits Easily with the Agilent Multimode Inlet (MMI) Application Note All Industries Authors Bill Wilson and Chin-Kai Meng Agilent Technologies, Inc. 2850 Centerville Road Wilmington,
More informationTECHNICAL INFORMATION
PRO-gran: TECHNICAL INFORMATION The ultimate in pitch performance PRO-gran: THE ULTIMATE PITCH INFILL PRO-gran has literally changed the game in high-performance infill for artificial sports pitches. A
More information15th ETH-Conference on Combustion Generated Nanoparticles June 26th 29th 2011
15th ETH-Conference on Combustion Generated Nanoparticles June 26th 29th 2011 Comparison of Genotoxicity of Exhaust from a Diesel, Biodiesel and Rapeseed Oil Powered Engine pilot study Jan Topinka 1, Alena
More informationStudy of viscosity - temperature characteristics of rapeseed oil biodiesel and its blends
Study of viscosity - temperature characteristics of rapeseed oil biodiesel and its blends Li Kong 1, Xiu Chen 1, a, Xiaoling Chen 1, Lei Zhong 1, Yongbin Lai 2 and Guang Wu 2 1 School of Chemical Engineering,
More informationFuel and Aftertreatment Effects on Particulate and Toxic Emissions from GDI and PFI Vehicles: A Summary of CE-CERT s Research
Fuel and Aftertreatment Effects on Particulate and Toxic Emissions from GDI and PFI Vehicles: A Summary of CE-CERT s Research Georgios Karavalakis, Ph.D. University of California, Riverside Center for
More informationCERTIFICATE OF ACCREDITATION
CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board/ACLASS 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that Eurofins Toxics, Inc. 180 Blue Ravine
More informationSUPPRESSION IN ANALYSIS OF ARTIFICIAL SWEETENERS WITH
APPROACHES TO DECREASE ION SUPPRESSION IN ANALYSIS OF ARTIFICIAL SWEETENERS WITH UPLC-TQ MS Noora Perkola Finnish Environment Institute 3rd Nordic MS Symposium September 12 2012, Jurmala, Latvia ARTIFICIAL
More informationApplication Note. Author. Abstract. Energy & Chemicals - Petrochemicals. Edgar Naegele, Agilent Technologies, Inc. Waldbronn, Germany
Determination of Aromatic Hydrocarbons in Petroleum Middle Distillates with the Agilent Infinity Binary HPLC System with RID Detection According to IP9()/ASTM D9 Application Note Energy & Chemicals - Petrochemicals
More informationMethod Detection Limits for EPA Method 8015 Diesel Range Organics using Fully Automated Extraction and Concentration
Method Detection Limits for EPA Method 8015 Diesel Range Organics using Fully Automated Extraction and Concentration Michael Ebitson, David Gallagher, Horizon Technology, Inc. Key Words EPA Method 8015,
More informationThis document is a preview generated by EVS
TECHNICAL REPORT RAPPORT TECHNIQUE TECHNISCHER BERICHT CEN/TR 16998 November 2016 ICS 13.040.20 English Version Ambient air - Report on nitro- and oxy-pahs - Origin, toxicity, concentrations and measurement
More informationZürich Testing on Fuel Effects and Future Work Programme
Zürich Testing on Fuel Effects and 2016-2017 Future Work Programme Benjamin Brem 1,2, Lukas Durdina 1,2 and Jing Wang 1,2 1 Empa 2 ETH Zürich FORUM on Aviation and Emissions Workshop Amsterdam 15.04.2016
More informationGC Best Practices & Troubleshooting. Group/Presentation Title Agilent Restricted Month ##, 200X
GC Best Practices & Troubleshooting Group/Presentation Title Agilent Restricted Month ##, 200X Troubleshooting Tips 1. Isolate the problem. (Blank Runs, Inject Un-retained Compound, Know what it is not)
More information5 PHASE GC COLUMNS DISCOVER NEW OPTIONS. Phenomenex I Web:
5 PHASE GC COLUMNS DISCOVER NEW OPTIONS ZEBRON 5 PHASE GC COLUMNS Choosing the Correct 5 Phase Column Equivalent to USP Phase G27 Low bleed (MS Certified) especially suited to high sensitivity work using
More informationDetermination of Free and Total Glycerin in B100 Biodiesel
Page 1 of 5 Page 1 of 5 Return to Web Version Determination of Free and Total Glycerin in B100 Biodiesel By: Michael D. Buchanan, Katherine K. Stenerson, and Vicki Yearick, Reporter US Vol 27.1 techservice@sial.com
More informationThe Stability of Sulfur Compounds, Low Molecular Weight Gases, and VOCs in Four Air Sample Bag Materials
The Stability of Sulfur s, Low Molecular Weight Gases, and VOCs in Four Air Sample Bag Materials Linda Coyne Cindy Kuhlman Nicole Zovack SKC Inc. Eighty Four, PA 15330 25 January 2011 Publication 1805
More informationPRODUCT SPECIFICATION. Product Specification Crystal 9000 Gas Chromatograph. Chromatec Crystal Laboratory Gas Chromatography System
Chromatec Crystal 9000 Laboratory Gas Chromatography System GC Chromatec-Crystal 9000 Crystal 9000 is a leading gas chromatograph in Chromatec GC product line. Crystal 9000 has highest performances and
More informationDiffusion Results for Rigid Porous Polyethylene Samplers
Diffusion Results for Rigid Porous Polyethylene Samplers Table 1: Metals 21-day Deployment Metals (mg/l)* (mg/l) * (mg/l)* (mg/l) * Antimony 0.0878 0.0810 92 0.0847 0.0799 94 Arsenic 0.0840 0.0768 91 0.0853
More informationOperation and Applications of Differential Flow Modulation
Operation and Applications of Differential Flow Modulation H2 Collection channel Column 1 H2 Column 2 FID Roger L Firor, Ph.D. Agilent Technologies Chemical Analysis Group Wilmington, DE USA Flow Modulator
More information