Diffusion Results for Rigid Porous Polyethylene Samplers
|
|
- Alisha Lewis
- 5 years ago
- Views:
Transcription
1 Diffusion Results for Rigid Porous Polyethylene Samplers
2 Table 1: Metals 21-day Deployment Metals (mg/l)* (mg/l) * (mg/l)* (mg/l) * Antimony Arsenic Barium Beryllium Cadmium Chromium Cobalt Copper Nickel Selenium Silver Thallium Vanadium Zinc ** Sampler concentration/ concentration X 100 Table 2: 1,4-Dioxane 28-day Deployment (ug/l)* (ug/l) * (ug/l)* (ug/l) * 1,4-Dioxane ** Sampler concentration/ concentration X 100 Wet Chemistry Table 3: Wet Chemistry (ug/l*) Sampler (ug/l) * Perchlorate Chloride Hexavalent Chromium Nitrate Nitrogen Sulfate ** Sampler concentration/ concentration X 100 In this study the worked well for volatiles, except for those of low water solubility (see Table 5-6, Columbia Analytical Services, 2005). It is theorized that the less soluble compounds partially sorbed to the polyethylene material. Table 4: Volatile Organic Compounds Volatile Organics Spiked Solubility (g/100 ml) (ug/l)* (ug/l) * Acetone 160 very Benzene Bromodichloromethane
3 Volatile Organics, (continued) Spiked Solubility (g/100 ml) (ug/l) (ug/l) Bromoform Bromomethane Butanone (MEK) Methyl tert-butyl Ether (MTBE) Carbon Disulfide Carbon Tetrachloride Chlorobenzene Chloroethane Chloroform Chloromethane Dibromochloromethane ,1-Dichloroethane ,2-Dichloroethane (EDC) ,1-Dichloroethene cis-1,2-dichloroethene trans-1,2-dichloroethene ,2-Dichloropropane cis-1,3-dichloropropene 81 < trans-1,3-dichloropropene 80 < Ethylbenzene Hexanone Methylene Chloride Methyl-2-pentanone (MIBK) Styrene ,1,2,2-Tetrachloroethane Tetrachloroethene (PCE) Toluene ,1,1-Trichloroethane (TCA) ,1,2-Trichloroethane Trichloroethene (TCE) Vinyl Chloride o-xylene m+p-xylenes ** Sampler concentration/ concentration X 100 Table 5: Methane, Ethane, Ethene Spiked (ug/l) (ug/l) Methane Ethane Ethene ** Sampler concentration/ concentration X 100 3
4 Studies were also performed for semivolatile compounds, this time using 4 L glass carboys. Again sorbing of poorly soluble compounds was evidenced. Table 6: Semivolatile Organics Semivolatiles 7-day Deployment 21-day Deployment (Spiked at 264 ug/l) Sampler N-Nitrosodimethylamine Aniline Bis(2-chloroethyl) Ether Phenol Chlorophenol ,3-Dichlorobenzene ,4-Dichlorobenzene ,2-Dichlorobenzene Benzyl alcohol Bis(2-chloroisopropyl) Ether Methylphenol Hexachloroethane N-Nitrosodi-n-propylamine Methylphenol Nitrobenzene Isophorone Nitrophenol ,4-Dimethylphenol Bis(2-chloroethoxy)methane ,4-Dichlorophenol Benzoic acid ,2,4-Trichlorobenzene Naphthalene Chloroaniline Hexachlorobutadiene Chloro-3-methylphenol Methylnaphthalene Hexachlorocyclopentadiene ,4,6-Trichlorophenol ,4,5-Trichlorophenol Chloronaphthalene Nitroaniline Acenaphthylene Dimethyl Phthalate ,6-Dinitrotoluene Acenaphthene Nitroaniline ,4-Dinitrophenol Dibenzofuran Nitrophenol
5 Semivolatiles (continued) 7-day Deployment 21-day Deployment (Spiked at 264 ug/l) 2,4-Dinitrotoluene Fluorene Chlorophenyl Phenyl Ether Diethyl Phthalate Nitroaniline Methyl-4,6-dinitrophenol N-Nitrosodiphenylamine Bromophenyl Phenyl Ether Hexachlorobenzene Pentachlorophenol Phenanthrene Anthracene Di-n-butyl Phthalate Fluoranthene Pyrene Butyl Benzyl Phthalate ,3'-Dichlorobenzidine Benz(a)anthracene Chrysene Bis(2-ethylhexyl) Phthalate Di-n-octyl Phthalate Benzo(b)fluoranthene Benzo(k)fluoranthene Benzo(a)pyrene Indeno(1,2,3-cd)pyrene Dibenz(a,h)anthracene Benzo(g,h,i)perylene * Sampler concentration/ concentration X 100 Taken from: Various Bench Study Test Results of the Use of RPP Columbia Analytical Services, Inc., Environmental Monitoring and Data Quality Workshop, April 5 7, San Antonio, TX
Texas Commission on Environmental Quality
Method EPA 1311 TCLP TX 849 10118806 Method EPA 1312 SPLP TX 850 10119003 Method EPA 150.1 ph TX 1900 10008409 Method EPA 160.1 Residue-filterable (TDS) TX 1955 10009208 Method EPA 1664 n-hexane Extractable
More informationSAN ANTONIO WATER SYSTEM
Detection Limit Concentration Range CONSTITUENTS for Reporting Found MCL Hardness as CaCO3 (mg/l) 1.50 338 to 348 Total dissolved solids (mg/l) 5.00 392 to 448 500 ** Specific Conductance (umhos/cm) 639
More informationTexas Commission on Environmental Quality
Matrix: Air & Emissions Method EPA TO-15 1,1,1-Trichloroethane TX 5160 10248803 1,1,2,2-Tetrachloroethane TX 5110 10248803 1,1,2-Trichloro-1,2,2-trifluoroethane (Freon 113) TX 5195 10248803 1,1,2-Trichloroethane
More informationPlease contact your Project Manager if you have any questions or concerns pertaining to this report. Report Authorization Date 24-APR-2016
Live Safer TM NSF International 789 N. Dixboro Rd. Ann Arbor, MI 8105, USA 1-800.NSF.MARK +1-7.769.8010 www.nsf.org TEST REPORT Send To: L10 Mr. Colman Dungan Precision Associates Inc. 800 Washington Avenue
More informationANALYTICAL RESULTS. PWS ID/Name: ROCKHOUSE MOUNTAIN - CONWAY Report Date: 03/29/2016
10014605 Analyzing Lab: 1012-EASTERN ANALYTICAL INC ANTIMONY, TOTAL ND MG/L.001 1 03/18/2016 ARSENIC, TOTAL 0.002 MG/L.001 1 03/18/2016 BARIUM, TOTAL 0.005 MG/L.001 1 03/18/2016 BERYLLIUM, TOTAL ND MG/L.001
More informationTABLE 3.A. Specific Ground Water Quality Criteria for Organic Contaminants Ground Water Quality Criteria,
TABLE 3.A. Specific Ground Water Quality Criteria for Organic Contaminants Ground Water Quality Criteria, µg/l Practical Quantitation Levels, µg/l Higher of PQLs and GWQ Criteria, µg/l Contaminant CAS#
More informationSRV Comparison. DRAFT June of 6
Inorganics Aluminum 7429-90-5 30000 40000 See BTV Eval 100000 100000 100000 Antimony 7440-36-0 12 16 6.2 100 93 60 Arsenic 7440-38-2 9 11 9 20 9 70 Barium 7440-39-3 1100 1100 3000 18000 35000 14000 Beryllium
More informationNew Integrated GC Guard Columns for Built-In Protection
New Integrated GC Guard Columns for Built-In Protection GUARDIAN: Quick and Easy to Set-up With Guardian you get your column plus 5 or 10 meters of additional integrated deactivated tubing. However, it
More informationTexas Commission on Environmental Quality
NELAP ~ Recognized Laboratory Fields of Accreditation These fields of accreditation supercede all previous fields. The urges customers to Matrix: Air & Emissions Method EPA T0-15 1, 1, 1-T rich loroethane
More informationPlease contact your Project Manager if you have any questions or concerns pertaining to this report.
Live Safer TM NSF International 7 N. Dixboro Rd. Ann Arbor, MI 4, USA 1-00.NSF.MARK +1-734.7.0 www.nsf.org TEST REPORT Send To: 3A240 Mr. Matt Brown Bluescope Bartlett Liners Pty. Ltd. 172 Ring Road Ballarat
More informationEPA 625: Base, Neutral, Acid Semivolatiles in Municipal and Industrial Waste Water by Solid Phase Extraction
EPA 625: Base, Neutral, Acid Semivolatiles in Municipal and Industrial Waste Water by Solid Phase Extraction Tom Hall, Fluid Management Systems, Watertown, MA Overview Development of a fully automated
More informationCERTIFICATE OF ACCREDITATION
CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board/ACLASS 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that Eurofins Toxics, Inc. 180 Blue Ravine
More information2014 ANNUAL REPORT INDUSTRIAL WASTE PRETREATMENT PROGRAM COUNTY SANITATION DISTRICTS OF LOS ANGELES COUNTY
2014 ANNUAL REPORT INDUSTRIAL WASTE PRETREATMENT PROGRAM COUNTY SANITATION DISTRICTS OF LOS ANGELES COUNTY GRACE ROBINSON HYDE CHIEF ENGINEER AND GENERAL MANAGER SUBMITTED February 27, 2015 APPENDIX G
More informationZB-5ms GC Columns. Aromatic Compounds
ZB-5ms GC Columns Enchanced Resolution of Aromatic Compounds ARYLENE MATRIX TECHNOLOGY Traditionally, GC/MS bleed certification had been achieved by incorporating a column s phenyl character into the polymer
More informationEPA Method 625: Determination of Bases, Neutrals and Acids by Solid Phase Extraction and GC/MS Detection
EPA Method 625: Determination of Bases, Neutrals and Acids by Solid Phase Extraction and GC/MS Detection UCT Part Numbers: EC82701M15-1000 mg 8270 sorbent/15 ml cartridge or EC82702M15-2000 mg 8270 sorbent/15
More informationSpring 2015 Summary Report Residential Drinking Water Well Sampling LRI Landfill
Spring 2015 Summary Report Residential Drinking Water Well Sampling LRI Landfill Contents 1. Summary 2. Table 1 Spring 2015 Water Quality Results 3. Table 2 Spring 2015 Water Quality VOC Results 4. Table
More informationUnderground Storage Tank Monitoring State Of California visit us online at
At-a-Glance Product Information from Restek To help laboratories comply with and use these analytical procedures, Restek has been active in following the state guidance. Based on our good knowledge of
More informationOrganic, Inorganic, and Microbiological Reference Materials Certified Reference Materials
Organic, Inorganic, and Microbiological Reference Materials Certified Reference Materials Table of Contents Extraction Spiking Solutions for Environmental Analyses Method 8270 LCS Snip pg. 4 Benzidines
More informationOrganic, Inorganic, and Microbiological Reference Materials Certified Reference Materials
www.nsistandards.com Organic, Inorganic, and Microbiological Reference Materials Certified Reference Materials Table of Contents Extraction Spiking Solutions for Environmental Analyses Method 8270 LCS
More informationRemedial Alternative Cost Issues Tremont City Barrel Fill, Clark County, Ohio Ohio EPA, June, 2014
Remedial Alternative Cost Issues Tremont City Barrel Fill, Clark County, Ohio Ohio EPA, June, 2014 Alternative 4a The $13,808,400 1 cost estimate for off-site treatment and disposal of 37,000 tons of characteristic
More informationCargill Fertilizer, Inc. Riverview Fertilizer Plant
Bioassays of Cargill Fertilizer, Inc. Riverview Fertilizer Plant Hillsborough County NPDES #FL0177130 Sampled July 26, 2004 November 2004 Biology Section Bureau of Laboratories Division of Resource Assessment
More informationSemi-Annual Groundwater Monitoring Report
Semi-Annual Groundwater Monitoring Report 4] Facility Name: Wade's Lane Landfill 6] Operational Status: Closed 7] GW Program: Assessment Monitoring 9] Simplified Site Location Description: 28.5 acre tract
More informationTable C 15. TAC Emissions Summary and Ambient Air Impact Concentrations. FCA Mack Avenue Assembly Plant Update February 2019
Paint Sealer Oven Prime Obs BC1 Obs BC2 Obs CC1 Obs CC2 Obs Concentrator RTO Rapid Reprocess Spot Prime General Building Ventilation 2 Prime Oven 1 Prime Oven 2 (lb/hr) (lb/hr) (lb/hr) (lb/hr) (lb/hr)
More informationAUTONOMOUS, REAL TIME DETECTION OF 58 VOCS IN THE PANAMA CANAL
AUTONOMOUS, REAL TIME DETECTION OF 58 VOCS IN THE PANAMA CANAL Challenges of Water Monitoring Volatile Organic Compounds (VOCs) can have negative health impacts even at ppb levels VOC concentrations can
More informationAPPENDIX C.2 CCWF 10-YEAR TRAVEL TIME WATER QUALITY
APPENDIX C.2 CCWF 10-YEAR TRAVEL TIME WATER QUALITY Table C.2 Chino Creek Well Field Proposed Water Quality and Regulatory Limits Chino Desalter Phase 3 PDR JCSD/Ontario/WMWD USEPA Primary 1,1,1-Trichloroethane
More informationThis annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation
Annex to declaration accreditation (scope accreditation) (s) where activities are performed under accreditation Head Office Steenhouwerstraat 15 3194 AG Hoogvliet Rotterdam The Netherlands Abbreviation/
More informationENVIROTEK LABORATORIES, INC. Bordentown, New Jersey PHONE EPA ID # NJ01298 NJ DEP ID # TEST RESULTS FOR
TM ENVIROTEK LABORATORIES, INC. TEST RESULTS FOR ProPur Water Purification Systems 1200 BENSTEIN ROAD COMMERCE TWP. MICHIGAN, 48390 ProMax Shower Filter NSF Standard 53, and NSF Standard 42 Chemical Tests
More informationTEKLAB, INC ANALYTICAL QC SUMMARY REPORT. CLIENT: Kelron Environmental Work Order: Project: CHMGP/ Page 1 of 6.
TEKLAB, INC CLIENT: Kelron Environmental Date: 27-Dec-6 Sample ID: MB-3498 SampType: MBLK SeqNo: 145961 Acenaphthene ND.1 Acenaphthylene ND.1 Anthracene ND.1 Benzo(a)anthracene ND.1 Benzo(a)pyrene ND.1
More informationXLB. 1-MS Accent. 5-MS Accent. MACHEREY-NAGEL
The new ultra low bleed high performance GC columns 1-MS Accent 5-MS Accent XLB MACHEREY-NAGEL MN Demands on state-of-the-art fused silica capillary GC columns: lowest column bleed for ultra trace analysis
More informationApril 16, Mr. Stephen Jerrick A. Morton Thomas & Associates, Inc. 800 King Farm Blvd, Fourth Floor Rockville, MD 20850
April 16, 2018 Mr. Stephen Jerrick A. Morton Thomas & Associates, Inc. 800 King Farm Blvd, Fourth Floor Rockville, MD 20850 Re: Quarterly Monitoring Report 1 st Quarter 2018 Groundwater Monitoring North
More informationJuly 19, Dear Ms. Hanson:
July 19, 2016 Ms. Richelle Hanson, Project Manager Land Restoration Program Land Management Administration Maryland Department of the Environment 1800 Washington Boulevard, Suite 625 Baltimore, Maryland
More informationJanuary 26, Dear Ms. Hanson:
January 26, 2017 Ms. Kelly M. Hanson Engineer Metropolitan Council Environmental Services Industrial Waste & Pollution Prevention Section 390 North Robert Street St. Paul, Minnesota 55101-1805 RE: 4th
More informationVIA ELECTRONIC MAIL. February 5, 2019
VIA ELECTRONIC MAIL February 5, 2019 Erich Weissbart, P.G. Remedial Project Manager Land and Chemicals Division U.S. Environmental Protection Agency, Region III 701 Mapes Road Fort Meade, MD 20755 Subject:
More informationEnvironmental Excavation Oversight
Environmental Excavation Oversight Approximately 10-Acres of Undeveloped Land East 120 th Avenue and Grant Street Northglenn, Adams County, Colorado February 26, 2013 Terracon Project No. A for: Northglenn
More informationAddendum No. 3. Soil Remediation at Forest Blvd East St. Louis, Illinois
Addendum No. 3 Soil Remediation at Forest Blvd East St. Louis, Illinois TO: FROM: All Plan Holders Sherman Carter Barnhart Architects 2405 Harrodsburg Road Lexington, Kentucky 40504 DATE: July 23, 2018
More informationTest Report. Final conclusion: PASS SHA18. Gohandmade Dsign International A/S HANNE Madevej Aabenraa DENMARK
Gohandmade Dsign International A/S HANNE Madevej 11-13 6200 Aabenraa DENMARK Date of order: 14.06.18 Contact: Penny Guo Direct dial: +86(21) 60725688 x 5659 Email: penny.guo@hansecontrol.com Test Report
More informationMACTEC Engineering & Consulting 5628 East Slauson Avenue 12-Nov-09 14:21 ANALYTICAL REPORT FOR SAMPLES
Figure G-1.24 Figure G-1.25 Figure G-1.26 MACTEC Engineering & Consulting Project: MAC110409-11 5628 East Slauson Avenue Project Number: Metro Westside Ext. / Wilshire Blvd. Reported: Los Angeles, CA 90040-2922
More informationMay 26, Erich Weissbart, P.G. Land and Chemicals Devision U.S. Environmental Protection Agency, Region III 701 Mapes Road Fort Meade, MD 20755
May 26, 2017 Erich Weissbart, P.G. Land and Chemicals Devision U.S. Environmental Protection Agency, Region III 701 Mapes Road Fort Meade, MD 20755 Re: Quarterly Status Report No. 2 - Offsite Area Former
More informationUpper Cap Concentrations for Substances Listed in the Contaminated Sites Regulation. Version 3 Draft 4
PROTOCOL 11 FOR CONTAMNATED STES Upper Cap Concentrations for Substances Listed in the Contaminated Sites Regulation ersion 3 Draft 4 Prepared pursuant to Section 64 of the Environmental Management Act
More information8000 Series Methods - Resource Conservation and Recovery Act (RCRA)
458 - Resource Conservation and Recovery Act (RCRA) US EPA Method No. Compound Class US EPA Method No. Compound Class free data Available on Our Website: Lot Certificates, Data Packs, and MSDSs For complete
More informationVIA ELECTRONIC MAIL. August 2, 2018
VIA ELECTRONIC MAIL August 2, 2018 Erich Weissbart, P.G. Remedial Project Manager Land and Chemicals Division U.S. Environmental Protection Agency, Region III 701 Mapes Road Fort Meade, MD 20755 Subject:
More informationTUV Rheinland (India) Pvt. Ltd., Plot No. 328, Udyog Vihar, Phase-IV, Gurgaon, Haryana. Discipline Chemical Testing Issue Date
Last Amended on 28.05.2015 Page 1 of 20 I. TEXTILE & TEXTILE AUXILIARIES 1. Color Fastness to Artificial Light BS EN ISO 105-B02: 2014 EN ISO 105-B02: 2014 ISO 105-B02: 2014 AATCC 16.3: 2012 GB/T 8427:
More informationAnalytical Reference Materials
Analytical Reference Materials NEW PRODUCTS FOR 2007 Chromatography Products 1 Searching for the perfect solution? Take these eight steps to create the right solution: 1. Mixture Description: 2. Solvent:
More informationdrinking water quality report
2017 drinking water quality report INC. VILLAGE OF GARDEN CITY PUBLIC WATER SUPPLY IDENTIFICATION NO. 2902824 ANNUAL WATER SUPPLY REPORT MAY 2018 The Village of Garden City is pleased to present to you
More informationReplacement Tubes for Gillian Gas Detection Pumps
236SA S 1,1,2-Trichloroethane (10-100 ppm) 235SA S 1,1-Dichloroethane (10-160 ppm) 230SA S 1,2-Dichloroethane (5-50 ppm) 145SA S 1,2-Dichloroethylene (4.2-840 ppm) 194S S 1,3-Dichloropropane (10-500 ppm)
More informationHeadspace Vials, Caps, and Septa Capillary Columns Syringes Hydrogen Generators
PerkinElmer continues to drive innovation and performance in Gas Chromatography (GC) instrumentation and software, with a strong focus on making your lab more productive. Backed by our worldwide, world-class
More informationResidual Solvent Analysis
Residual Solvent Analysis Complete Solutions for Residual Solvent Testing How to successfully implement the USP revision. Improve system suitability pass rates with an optimized system. Save column
More informationInvestigation of Indoor Air Sources of VOC Contamination. Clifford P. Weisel, Ph.D. Environmental and Occupational Health Sciences Institute
Investigation of Indoor Air Sources of VOC Contamination Clifford P. Weisel, Ph.D. Environmental and Occupational Health Sciences Institute RWJMS/UMDNJ, Piscataway, NJ Submitted to: New Jersey Department
More informationinorganic Organic / inorganic Organic 2011/12
Organic / inorganic C E R T I F I E D R E F E R E N C E M AT E R I A L S Organic 2011 2012 2011/12 C E R T I F I E D R E F E R E N C E M AT E R I A L S C E R T I F I E D R E F E R E N C E M AT E R I A
More informationTechnical Support Document for Draft Air Emission Permit No
Technical Support Document for Draft Air Emission Permit No. 06900015-101 This technical support document (TSD) is intended for all parties interested in the draft permit and to meet the requirements that
More information2017 Water Analysis Report
Spring Primary Inorganics Antimony 0.001 0.006 ND ND ND ND ND ND Arsenic 0.002 0.01 ND ND ND ND ND ND Asbestos (MFL) 0.2 7 ND ND ND ND ND ND Barium 0.1 2 ND ND ND ND ND ND Beryllium 0.001 0.004 ND ND ND
More informationPlease contact your Project Manager if you have any questions or concerns pertaining to this report. Report Authorization Date 07-APR-2015
Live Safer TM NSF International 789 N. Dixboro Rd. Ann Arbor, MI 480, USA -800.NSF.MARK +-734.769.800 www.nsf.org TEST REPORT Send To: L960 Mr. Denis Bigand Naya Waters Inc. 00 Rue Naya Mirabel, Québec
More information2017 Water Analysis Report
2017 Analysis Report Drinking w/fluoride Distilled Primary Inorganics Antimony 0.001 0.006 ND ND ND ND Arsenic 0.002 0.01 ND ND ND ND Asbestos (MFL) 0.2 7 ND ND ND ND Barium 0.1 2 ND ND ND ND Beryllium
More informationPlease contact your Project Manager if you have any questions or concerns pertaining to this report.
Live Safer TM NSF International 789 N. Dixboro Rd. Ann Arbor, MI 480, USA -800.NSF.MARK +-734.769.800 www.nsf.org TEST REPORT Send To: 360 Mr. Dewayne Cansler Mountain Valley Spring Company 0 Central Avenue
More informationChromatography Guide for
Chromatography Guide for Environmental Environmental Testing Testing Our Commitment to Environmental Testing In recent years, there has been a rapid, worldwide increase in environmental testing. The sudden
More informationTHE RESTEK ADVANTAGE
THE RESTEK ADVANTAGE Turning Visions into Reality Versatile GC Columns for Forensics Use an Rtx -BAC1 / Rtx -BAC2 Column Set To Evaluate Blood Alcohol, Abused Substances, and Other Materials By Kristi
More informationProof of Long-Term, Leak-Free Performance for a Novel Self-tightening GC Column Nut
Proof of Long-Term, Leak-Free Performance for a Novel Self-tightening GC Column Nut Application Note Environmental Author Ken Lynam Agilent Technologies, Inc. Abstract Specially designed self-tightening
More information5 PHASE GC COLUMNS DISCOVER NEW OPTIONS. Phenomenex I Web:
5 PHASE GC COLUMNS DISCOVER NEW OPTIONS ZEBRON 5 PHASE GC COLUMNS Choosing the Correct 5 Phase Column Equivalent to USP Phase G27 Low bleed (MS Certified) especially suited to high sensitivity work using
More informationChromatography Guide for
Chromatography Guide for Environmental Environmental Testing Testing Our Commitment to Environmental Testing In recent years, there has been a rapid, worldwide increase in environmental testing. The sudden
More informationBadoit Sparkling Natural Mineral Water Annual Water Quality Report
Badoit Sparkling Natural Mineral Water Annual Water Quality Report At Badoit we are proud of the quality of our products. Badoit Sparkling Natural Mineral Water meets or exceeds all bottled water standards
More informationNew Developments in Ionic Liquid GC Stationary Phases
New Developments in Ionic Liquid GC Stationary Phases L.M.Sidisky, G. A. Baney, J.L. Desorcie, D.L. Shollenberger, G. Serrano, K.K. Stenerson May 1, 2013 ISCC, Palm Springs, CA sigma-aldrich.com/analytical
More informationHow to Use the Chemical Compatibility Chart. Vials and Closures >> Chemical Compatibility Chart
How to Use the Chemical Compatibility Chart The following chart contains information regarding the expected effects of 7 day direct solvent exposure on materials used for production of vials, caps and
More informationEvaluation report. tests of material samples for the parameters heavy metals (Pb, Cd, Cr, Cu, Ni, Zn, Hg) LVHH, BTEX, PDH, PAH and EOX
Competenza GmbH Burgbernheimer Straße 16 D-90431 Nürnberg HAGA AG Naturbaustoffe Mr. Thomas Bühler Hübelweg 1 CH-5102 Rupperswill report on tests of material samples for the parameters heavy metals (Pb,
More informationProposed Sydport Container Terminal-Sydney Harbour Sediment Quality Analysis
Project No.1034272 February 11, 2008 Mr. Jim Wooder, CEO Laurentian Energy Corperation 114 Marine Drive Edwardsville, NS B2A 4S6 Dear Mr. Wooder: Re: Proposed Sydport Container Terminal-Sydney Harbour
More informationParamount Chemical Guide
Paramount Chemical Guide Use this table to evaluate additional chemicals that you may decide to use after the Paramount has been set up for its intended application. Following the table is a chart key
More informationTECHNICAL INFORMATION
PRO-gran: TECHNICAL INFORMATION The ultimate in pitch performance PRO-gran: THE ULTIMATE PITCH INFILL PRO-gran has literally changed the game in high-performance infill for artificial sports pitches. A
More informationTest Report. Dec. 21, 2015 The following sample(s) and sample information was/were submitted and identified by/on the behalf of the client
Report No. SCL0H07706 Page of Dec. 2, 20 The following sample(s) and sample information waswere submitted and identified byon the behalf of the client Sample Description SB Series Ink: COOL GREY #6, SUPERWHITE,
More informationFILTRATION SYSTEMS CARBOX PHARMACEUTICAL HOODS ACTIVATED CHARCOAL FILTERS
CARBOX FILTRATION SYSTEMS 47 Filtration systems for the treatment of harmful fumes resulting from chemical processings. INDEX PHARMACEUTICAL HOODS 49 ACTIVATED CHARCOAL FILTERS 53 48 CAP-FARM 60 Aspirated
More informationVOC Chek 575 Series Selection Guide ppm-level Sampling of Organic Vapors
VOC Chek 575 Series Selection Guide ppm-level Sampling of Organic Vapors Series Passive Samplers are available with sorbents such as activated carbon and Anasorb 747 that strongly retain the collected
More information[Date of order] [Date of delivery] [Date]
CTL GmbH ChemicalTechnological Laboratory Krackser Straße 12 33659 Germany B&G Amsterdam b.v. Mr Schory San Franciscostraat 32 1175RE Lijnden THE NETHERLANDS Marion Hahn [fon] +49 521 400 82 89 13 [mail]
More informationThe Stability of Sulfur Compounds, Low Molecular Weight Gases, and VOCs in Four Air Sample Bag Materials
The Stability of Sulfur s, Low Molecular Weight Gases, and VOCs in Four Air Sample Bag Materials Linda Coyne Cindy Kuhlman Nicole Zovack SKC Inc. Eighty Four, PA 15330 25 January 2011 Publication 1805
More informationAPPENDIX A TABLE 3 - MEDIUM-SPECIFIC CONCENTRATIONS (MSCs) FOR ORGANIC REGULATED SUBSTANCES IN SOIL B. Soil to Groundwater Numeric Values 1
B. to Groundwater Numeric Values 1 ACENAPHTHENE 83-32-9 220 2700 E [350] 380 [4300] 4700 E [350] 380 [4300] 4700 E [350] 380 [4300] 4700 E [350] 380 [4300] E [350] 380 [4300] E 15 4700 4700 ACENAPHTHYLENE
More informationPHASE II ENVIRONMENTAL SITE ASSESSMENT HOWARD UNIVERSITY EAST CAMPUS (DIVINITY SCHOOL) 1400 SHEPHERD STREET, NE WASHINGTON, DC
PHASE II ENVIRONMENTAL SITE ASSESSMENT HOWARD UNIVERSITY EAST CAMPUS (DIVINITY SCHOOL) 1400 SHEPHERD STREET, NE WASHINGTON, DC ECS PROJECT NO. 47:6230-A FOR ZOM MID-ATLANTIC, INC AUGUST 24, 2018 August
More informationNeslihan Sözer Chemical Laboratory Manager
TEST REPOR Page 1 of 8 REPORT NUMBER : TURA120082950 APPLICANT NAME ADDRESS Karslıoğlu Kırt. San. ve Tic. A.Ş. Davutpaşa Cad. Yılanlı Ayazma Yolu Uğur Plaza No:4/B Davutpaşa İstanbul TURKEY Faks No :0212
More informationEnvironmental Baseline Data Report Hardrock Project: 2015 Air Quality Monitoring Program
Environmental Baseline Data Report Hardrock Project: 2015 Air Quality Monitoring Program Prepared for: Greenstone Gold Mines GP Inc. 365 Bay St, Suite 500 Toronto, ON M5H 2V1 Prepared by: Stantec Consulting
More informationHeavy Fuel Oil 6303 (2002)
Origin Imperial Oil Ltd., Nova Scotia, Canada (2002) Synonyms: Bunker C, Land Bunker API Gravity 11.47 (calc) Equation for Predicting Evaporation %Ev = ( -0.16 + 0.013 T) t 1/2 Where: %Ev = weight percent
More informationPrepared for: Lockheed Martin Corporation. Prepared by: Tetra Tech, Inc. September Michael Martin, P.G. Regional Manager
Construction Documentation Sub-Slab Depressurization System Second-Phase Expansion Building C Lockheed Martin Middle River Complex 2323 Eastern Boulevard Middle River, Maryland Prepared for: Lockheed Martin
More informationDiesel Particulate Matter Thursday 11 June 2015
Presentation Diesel Particulate Matter Thursday 11 June 2015 Allison Golsby MEngSc (MinIndMan), MMinEng (MineGeomech), GradDipMVent, MAusIMM(CP), RPEQ Chief Executive Officer GPO Box 358 allison@consultmine.com.au
More informationComplete Fractionation of Extractable Petroleum Hydrocarbons Using Newly Developed EPH SPE Cartridges
Complete Fractionation of Extractable Petroleum Hydrocarbons Using Newly Developed EPH SPE Cartridges Alexandria Pavkovich Jason Thomas Trent Sprenkle Outline Background EPA Method Requirements Background
More informationMethod-Specific Sample Preparation for EPH Analysis
Method-Specific Sample Preparation for EPH Analysis Resprep SPE Cartridges for Complete Extractable Petroleum Hydrocarbon Fractionation Full separation between fractions. Guaranteed low background level.
More informationDetermination of PAH Compounds from Aqueous Samples Using a Non-Halogenated Extraction Solvent and Atlantic C18 Disks
Determination of PAH Compounds from Aqueous Samples Using a Non-Halogenated Extraction Jim Fenster, Kevin Dinnean,, David Gallagher, Michael Ebitson, Horizon Technology, Inc., Salem, NH Introduction Polycyclic
More informationSynonym(s) ) Chlorine, liquefied/gas. Ammonia, Gasoline, natural 7300 (gasoline) Hydrogen gas. Phosgene
Use Quantities Standard for Hazardous Chemicals (2013) 1 Chlorine Chlorine, liquefied/gas 7782-50-5 2 Annonia Ammonia, 7664-41-7 3 Petroleum gases, liquified 0 68476-85-7 4 Hhdrogen Sulphide 7783-06-4
More informationITEX-2 Option. High Sensitivity Enrichment Technique for Gas Chromatography
ITEX-2 Option Prep and Load Platform High Sensitivity Enrichment Technique for Gas Chromatography Environmental / Drinking Water Food / Flavour / Consumer Products Forensics / Toxicology Petrochemicals
More information[ Date of order ] [ Date of delivery ] [ Date ]
CTL GmbH ChemicalTechnological Laboratory Krackser Straße 12 33659 Germany Tattoo Supplies UK Mr Cowie 9/11 Fast Fountainbridge EH3 9BH Edinburgh SCOTLAND Bettina Kaiser [fon] +49 521 400 82 89 17 [mail]
More informationPHASE II SUBSURFACE INVESTIGATION REPORT
PHASE II SUBSURFACE INVESTIGATION REPORT Perris-Indian & Markham-Land Indian Avenue & Markham Street Perris, California 92571 May 3, 2016 Partner Project Number: 16-158069.2 Prepared for: Duke Realty 8001
More informationColorimetric Gas Detector Tube System US Dollar Price List
Colorimetric Gas Detector Tube System US Dollar Price List Sensidyne, LP - Gas Detector Tube Price List Effective Date: February 12, 2012 Rev. A 010612 Table of Contents Gas Detection Pump Kit & Accessories
More informationAir Quality Monitoring Results Supplementary Data Department of Environment and Local Government
Air Quality Monitoring Results Supplementary Data 211 Department of Environment and Local Government New Brunswick Department of Environment and Local Government Environmental Reporting Series 213 This
More informationLaboratory Bureau Veritas Consumer Products Services Lanka (Pvt.) Ltd., No. 570, Galle Road, Katubedda, Moratuwa, Sri Lanka
Last Amended on - Page 1 of 14 I. TEXTILE & TEXTILE AUXILIARIES 1. Textiles- Fabric/Garment Colorfastness to Crocking AATCC 8: 2013 BS EN ISO 105-X12: 2002 AATCC 116: 2013 Colorfastness to Perspiration
More informationComplete Laboratory Solutions
Ros Muc, Connemara, Co.Galway Testing Laboratory Registration number: 108T is accredited by the Irish National Board (INAB) to undertake testing as detailed in the Schedule bearing the Registration Number
More informationPhysical properties of PET resins. 1. Intrinsic Viscosity (IV)
Physical properties of PET resins 1. Intrinsic Viscosity (IV) Intrinsic viscosity (IV) is a measure of polymer molecular weight, which in turn is a measure of the mechanical strength capability of the
More informationState of Alaska UST Monitoring
Contact Information At-a-Glance Product Information from Restek Alaska Department of Environmental Conservation 410 Willoughby Avenue Juneau, AK 99801-1795 Phone: (907) 465-5203 Fax: (907) 465 5218 www.state.ak.us/dec/deh/laboratories/ust.htm
More informationEmissions Characteristics of Volatile and Semi-volatile Organic Compounds and Polynuclear Aromatic Hydrocarbons (PAHs) from Hot and Warm Mix Asphalts
1/10 Emissions Characteristics of Volatile and Semi-volatile Organic Compounds and Polynuclear Aromatic Hydrocarbons (PAHs) from Hot and Warm Mix Asphalts Frank Farshidi, University of California, Davis,
More informationAppendix 1. Weyerhaeuser Company Dock Dredging Project: PSDDA Evaluation Summary B-1 B-2 B-3 B-4 B-5 B-6 B-7 B-8 B-9 B-10 DMMU Rank: H H H H H H H H H H SL freq CHEMICAL NAME Units SL BT ML Conc. VQ Conc
More informationPolycarbonate & Laminate Half Trays
Polycarbonate & Laminate Half Trays Positioning pg. 8-47 Premium Transparent Half Trays (Viewline Plus) 3/8 thick break-resistant polycarbonate Heavy-duty moisture-resistant tray for institutional or long
More informationAir Quality Monitoring Results
Air Quality Monitoring Results Supplementary Data 215 New Brunswick Department of Environment and Local Government New Brunswick Department of Environment and Local Government Environmental Reporting Series
More informationCeilcote Corrosion Resistant Guide
Ceilcote Corrosion Resistant Guide Monolithic Linings Monolithic Flooring Heavy-Duty Coatings Polymer Grouts Adhesives & Joint Fillers JULY 2012 INTRODUCTION Over 340 corrosive environments are classified
More information1996 Inventory of Toxic Air Emissions
1996 Inventory of Toxic Air Emissions Part II: Mobile Sources February 2000 Submitted by: Submitted to: Great Lakes Commission U.S. Environmental Protection Agency 400 Fourth Street Region 5 Ann Arbor,
More informationOffered by the IRSST. Price list ext August hone: Fax: Update:
S Laboratory Institut de recherche Robert-Sauvé en santé et en sécurité du travail Costumer Services - Laboratory Services and Expertise Research and Expertise Division Services Offered by the IRSST Price
More informationFlorida s Pollutants Tax on the production or importation of petroleum products, perchloroethylene, solvents, ammonia, chlorine, and pesticides.
Florida s Pollutants Tax on the production or importation of petroleum products, perchloroethylene, solvents, ammonia, chlorine, and pesticides. GT-800032 R. 10/09 Florida imposes a tax on the production
More informationUnderground Storage Tanks Compliance Monitoring with Restek Analytical Reference Materials
Underground Storage Tanks Compliance Monitoring with Restek Analytical Reference Materials Fuel Composite Standards.............. 3 Single Source Fuel Standards......... 3 4 Fuel Surrogate Standards...............
More information