General Information. Table of Contents. Information. General. Page Number

Size: px
Start display at page:

Download "General Information. Table of Contents. Information. General. Page Number"

Transcription

1 Page General Information UL and CSA Approvals...4 Warranty...5 Commercial Warranty...6 Generators Warranty...7 Abbreviations, Symbols and Voltage Codes...8 General Information...9 Single Phase TEFC...10 ODP...12 General Purpose and Standard-E TEFC, TENV...14 ODP...20 Super-E Premium Efficient TEFC...25 F2 Mount, TEFC...31 Explosion Proof, TEFC...31 ODP...32 F2 Mount, ODP...34 Washdown, TENV and TEFC...35 Super-E, All Stainless Steel, TEFC and TENV...36 Close-Coupled Pump, TEFC and ODP...37 Single Phase, TEFC...39 Single Phase, ODP...39 C-Face Single Phase, TEFC...40 Single Phase, ODP...41 Three Phase, TEFC and TENV, Less Base...42 Three Phase, ODP, Less Base...44 Three Phase, TEFC, With Base...45 Three Phase, ODP, With Base...47 Foot or C-Face Mounting, TENV, Removable Base...48 Severe Duty 460 and 230/460 Volts, Rigid Base Volts, Rigid Base Volts, C-Face...54 IEEE841, 460 Volts...56 IEEE841, 575 Volts...58 Medium Voltage, 2300/4160 Volt...59 Quarry Duty, TEFC...60 Crusher, TEFC...60 Dirty Duty...61 Washdown Duty Single and Three Phase, TENV and TEFC...62 Three Phase, Super-E Brake TEFC and TENV...64 Three Phase, Dirty Duty...65 Three Phase, Feather Picker, TEFC...66 Three Phase, Paint-Free, TEFC and TENV...66 Three Phase, SSE Super-E, All Stainless Steel, TEFC and TENV...67 Three Phase, All Stainless Steel, TEFC and TENV...68 Three Phase, Inverter, Paint Free Washdown...69 Three Phase, Vector, Washdown...70 Stainless Steel, Brushless AC Servo...70 Table of Contents General Information Page Explosion Proof Single and Three Phase, Rigid Base...71 Single and Three Phase, C-Face...74 Three Phase, 1.15 Service Factor...76 For Explosion-Proof Inverter, see page 163 Pump Single Phase, Jet Pump, TEFC and ODP...77 Three Phase, Jet Pump, TEFC...78 Three Phase, Jet Pump, ODP...79 Explosion Proof, Jet Pump...80 Square Flange, Pump, ODP...80 Single Phase, Close-Coupled, TEFC and ODP...81 Three Phase, Washdown, Close-Coupled, TENV and TEFC...82 Three Phase, Close-Coupled, TEFC and ODP...82 Three Phase, Close-Coupled, Explosion Proof...86 Three Phase, P-Base Vertical, 1.15 Service Factor, TEFC...87 Three Phase, P-Base Vertical, 1.15 Service Factor, ODP...88 Commercial Duty Single Phase, Jet Pump, ODP...89 Single Phase, Two Compartment, Jet Pump, ODP...90 Single Phase, Square Flange Pump, ODP...91 Single Phase, General Purpose, ODP, Resilient Base...92 Single and Three Phase, HVAC, OPAO, Resilient Base...93 Single and Three Phase, Direct Drive Fan, TEAO...94 Split Phase, Fan and Blower, ODP, Resilient Base...95 Incubator/Hatchery, Vent Fan, TEAO...95 Single Phase, Condenser Fan, TEAO...96 Single Phase, Indoor Blower, ODP...97 Single Phase, Yoke/Pedestal Fan, TEAO...98 Heating, Ventilating and Air Conditioning Single and Three Phase, Fan and Blower, ODP, Resilient...99 Three Phase, Chiller/Cooling Tower, TEAO Three Phase, ODP, Resilient Base Three Phase, ODP, Resilient and Rigid Base Three Phase, HVAC, Variable Torque, ODP Three Phase, HVAC, Variable Torque, TEFC Single Phase, Direct Drive Fan, TEAO Three Phase, ODP, Condenser Fan Three Phase, TEAO Farm Duty Single Phase, Rigid Base and C-Face Three Phase, TEAO, Rigid Base Single and Three Phase, Grain Dryer/Centrifugal Fan Single and Three Phase, Grain Dryer/Vane Axial Fan Single Phase, Universal Crop Dryer Three Phase, Irrigation Tower Drive Single Phase, Auger Drive, Flange Mount Single Phase, Grain Stirring Single Phase, Instant Reversing Single and Three Phase, Aeration Fan Single Phase, Dairy/Vacuum Pump Definite Purpose Three Phase, Two Speed, TEFC Three Phase, Two Speed, ODP General Information Single Phase General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Explosion Proof Pump Commercial 1

2 General Information Single Phase General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Explosion Proof Pump Commercial 2 Page Definite Purpose continued Single Phase, Pressure Washer, TEFC and ODP Three Phase, Metering Pump, TEFC Three Phase, Arbor Saw, TEFC Single Phase, Woodworking, TEFC Three Phase, Chiller/Cooling Tower, TEAO Single and Three Phase, Pre Three Phase Continuous Duty SAE Hydraulic Pump Three Phase, F-2 Mount, TEFC and ODP Three Phase, Automotive, TEFC Three Phase, Automotive, TENV Three Phase, Oil Field Pump, TEFC and ODP Single Phase, Gate Operator, ODP Single Phase, Door Operator, ODP Brake Three Phase, Super-E, TEFC Single and Three Phase, TEFC Single and Three Phase, C-Face, TEFC Three Phase, ODP Three Phase, Explosion Proof, C-Face Double C-Face Brake Kits Three Phase, Super-E Washdown, TEFC and TENV Three Phase, High Cycle and 575 Volt Three Phase, 200 Volt, TEFC Three Phase, 200 Volt, ODP Three Phase, 575 Volt, TEFC Three Phase, 575 Volt, ODP Three Phase, 575 Volt, Severe Duty, TEFC Three Phase, 575 Volt, IEEE Three Phase, 575 Volt, C-Face, TEFC Three Phase, 575 Volt, Close-Coupled, TEFC and ODP Three Phase, 575 Volt, Explosion Proof IEC Three Phase, Metric IEC Three Phase, TEFC (IP54), Rigid Base (IEC-B3) Three Phase, TEFC (IP54), Flange (IEC-B5) Three Phase, TEFC (IP54), B14 Face (IEC-B14) Metric Weld on Bases Three Phase, TEFC (IP54), B3 Face (IEC-B5, B14) Hertz Single Phase,, TEFC and ODP Three Phase,, TEFC and ODP Single and Three Phase,, TEFC, C-Face Single and Three Phase,, Explosion Proof, C-Face Inverter and Vector AC Adjustable Speed Range Capabilities Three Phase, Inverter, TEBC and TENV Three Phase, Inverter, Washdown, TENV Inverter Gear, TEFC Three Phase, Inverter, Paint Free Washdown Three Phase, Inverter, Explosion Proof Three Phase, Vector, TEBC and TENV Three Phase, Vector, Washdown, TEBC and TENV Table of Contents General Information Page Inverter and Vector continued Three Phase, Vector, Washdown, TENV Three Phase, Vector, Elevator Duty Blower Conversion Kits Cables and Kits Series 15J Mini Inverters Dynamic Braking Assemblies, Keypad with Cable Series 15P Mini Inverter Dynamic Braking Assemblies Series 5 Micro Inverters Smart 230 and 460 Volts Smart Washdown, TEFC, 230 and 460 Volts Smart Close-Coupled Pump, 230 and 460 Volts Cover with Keypad Jack Keypad with Cable, Keypad Mounted Covers Smart Dimension Diagrams H2 Inverter/Encoderless Vector H2 Inverter/Encoderless Vector, 230 Volts H2 Inverter/Encoderless Vector, 460 Volts H2 Inverter/Encoderless Vector, 575 Volts H2 Vector Drive H2 Vector Drive, 230 Volts H2 Vector Drive, 460 Volts H2 Vector Drive, 575 Volts H2 Drive Keypad Extension Cable H2 Drive Dynamic Braking Assemblies H2 Drive Expansion Boards Series 15H Inverter Series 15H Washdown Inverter Series 18H Vector Drive Series 18H WashdownVector Series 22H Line Regenerative Vector Control Accessories Three Phase, Line and Reactors Digital Speed Potentiometer Digital Tachometers Servo AC Servo, BSM C Series AC Servo, BSM N Series Stainless Steel Servo, SSBSM Series Cables and Assemblies H2 AC Servo Conrol Series 23H AC Servo Control Precision Gearheads for BSM Servo DC Servo and Cables DC Servo Controls DC Subractional Permanent Magnet DC, TENV SCR Permanent Magnet, TENV and TEFC, C-Face Permanent Magnet SCR Drive with Integral Tach Permanent Magnet SCR Drive, Explosion Proof Permanent Magnet SCR Drive, Washdown Permanent Magnet SCR Drive, Paint Free Metric Flange Permanent Magnet SCR Drive Low Voltage Permanent Magnet DC Power...231

3 Page DC continued SCR Drive, Shunt Wound SCR Drive, Shunt and Stabilized Shunt Wound DPFG SCR Drive, Shunt and Stabilized Shunt Wound DPBV SCR Drive, 240V Armature SCR Drive Shunt Wound Lifting Magnet Generators Tachometer Mounting Kits and Cooling Blowers Tachometer Generators Field Conversion Kits Fractional DC Speed Controls Enclosed DC Controls and Accessories Chassis Mount DC Controls Resistor and Fuse Kit X DC SCR Control and Accessories Line Regenerative DC Controls and Accessories Enclosed DC Control Specifications Chassis Mount DC Control Specifications Series 29 Digital DC Controls Series 30 Digital DC Controls Series 19H Digital DC Controls Series 20H Digital DC Controls Digital Speed Potentiometer Field Programmable Digital Tachometer Hall Effect Pickups Digital DC Controls Soft Starters and Dynamic Brakes Digital Soft Start Controls Digital Soft Start Controls, Dimensions and Accessores Multipurpose Soft Start Multipurpose Solid State Soft Start Single Phase Starter Definite Purpose Soft Start Three Phase Torque Control Multipurpose Dynamic Brake Gearmotors and Speed Reducers Single Phase, Right Angle, Gearmotor Inverter, Right Angle, Gearmotor Three Phase, Right Angle, Gearmotor Single Phase, Parallel Shaft, Gearmotor Three Phase, Parallel Shaft, Gearmotor Direct Current Permanent Magnet, Right Angle, Gearmortor Direct Current Permanent Magnet, Right Angle, Gearmotor Direct Current Permanent Magnet, Parallel Shaft, Gearmotor Series, Right Angle, Solid Shaft, Reducer Series, Right Angle, Hollow Shaft, Reducer Stainless Steel, Right Angle, Solid Shaft, Reducer Stainless Steel, Right Angle, Hollow Shaft, Reducer Washdown, Right Angle, Solid Shaft, Reducer Series, Right Angle, Coupling Type Solid Shaft, Reducer Series, Right Angle, Solid Shaft, Reducer /4-2 Gearmotors Universal Series, Right Angle Solid Shaft, Reducer Series Inline, Solid Shaft Reducer Series Right Angle, Hollow Bore, Reducer Ratio Multiplier, Solid Shaft, Reducer Table of Contents General Information Page Gearmotors and Speed Reducers continued Base Kits Flange, Riser Block and Torque Arm Kits Flange, Bushing and Double Reduction Adapter Kits Gear Reducer Selection and Application Data Accessories Field Conversion Kits C-Face, Brake and D-Flange Kits Drip Cover Kits Fan Cover/Conduit Box Kits Ball Bearing Kits Gear Accessories Adjustable Bases Conversion Bases and Metric Weld On Bases Automatic Greaser Coupling Guards Grinders Industrial Grinders Belt Grinders Industrial Buffers Big Red Grinders Grinder Accessories Grinder Wheels Polishing Lathes and Chucks Dust Collector Bags Generators Premier Portable Powerchief Portable Powerchief with Inverter Technology Diesel Portable Generator Accessories Mod Express Baldor Educational Classes Registration Form Class Descriptions Index District Office Locations Latin American Distributors Baldor Cross Reference Guide is now a separate catalog. To order use catalog number FM411. Pricing and Data subject to change without notice. General Information Single Phase General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Explosion Proof Pump Commercial 3

4 General Information Single Phase Approvals UL and CSA General Information AC --All 42 through 449T, equivalent IEC frame motors (Inverter and Vector Drive motors) are listed under UL recognized component file # E All 42 through 449T frame motors are listed under CSA recognized component, file # LR2262. TEFC or TEBC 5000 and 5800 frame motors up to 4160 volts, and a maximum of 900 HP-2 pole, 800 HP-4 pole, and 700 HP-6 pole are listed under CSA recognized component file # LR and 5800 ODP, WPI and WPII listing is pending. Explosion Proof -- UL listed file # E6951. All listed products, AC and DC frames 48 and 56 with Baldor type number X34** have CSA certified file # LR Other frame 56, and 143T through 215T have CSA certified file # LR frames 254T thru 449T have CSA certified file # LR General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Explosion Proof Pump Commercial DC -- All 42 through 184T frame motors and Subfractional HP DC motors and gear motors are listed under UL recognized component file # E All motors (except Subfractional motors) are listed by CSA recognized component file # LR2262. Integral HP wound field motors and generators (built in Ft Mill, SC) are listed by CSA, file number LR DC Tachometers -- XPY tachometers are UL recognized, file number E and CSA listed file number LR DC SCR Controls and Accessories -- Controls with catalog numbers BC138, BC139, BC140, BC140-FBR, BC141, BC142, BC155, BC154, BCWD140, BC160, BC200, BC201, BC202, BC203 and BC204 and accessories BC24-LF, BC145, BC146, BC147, BC151, BC211 and BC212 are UL listed for US and Canada, UL file number E BC153 is UL component recognized for US and Canada. BC254, BC354, BC214, BC215, BC216, BC217, BC218, BC245, BC253, BC258, BC259, DSP4-120, DSP4-240, DTM , DTM , HPU10, RK60-56 and RK are pending contact Baldor for status. Larger SCR controls Series 19H and 20H are UL and cul ed, UL file number E SCR controls Series 29D and 30D are UL and cul listed, UL file E AC Inverter and Vector Controls -- UL listed, file number E AC Soft Starters -- All units are CUL listed, file number E except catalog item S25CA. UL AND CSA EXPLOSION-PROOF CLASSIFICATIONS 1. Hazardous Locations Class I Group D locations are atmospheres containing elements such as Gasoline, Hexane, Naphtha, Benzine, Butane, Propane, Alcohol, Acetone, Benzol, Lacquer Solvent Vapors or Natural Gas. Class I Group C locations are atmospheres containing elements such as Ethyl-ether, Ethylene and Cyclopropane. Class II Group F & G locations are atmospheres containing dust such as (F) Carbon Black, coal or Coke Dust, (G) Flour, Starch or Grain Dusts. 2. As required by Underwriters Laboratories and Canadian Standards Association, explosion-proof motors with Class II Group F & G approvals must have over temperature protection. Explosion-Proof rated 1 1/2 HP or less have internally mounted automatic thermal overloads when indicated by suffix A. Caution must be observed when applying these to machinery applications to prevent accidental injury should the thermal device automatically reset and restart the motor. Explosion-Proof rated 1 HP and larger without automatic thermal overloads have thermostats in the windings. These thermostats are pilot circuit devices to be connected to the magnetic starter circuit. 3. Surface temperatures of Baldor Explosion-Proof will not exceed the following UL and CSA maximums under fault conditions. A. Class I, Group D listings only. Q with Class B insulation will not exceed surface temperatures of 230 C (446 F) equivalent Code T2C. Y with Class F insulation and 1.0 S.F. will not exceed surface temperatures of 280 C (536 F) equivalent to Code T2A. B. Class I, Group C & D listings only. T with Class F insulation and 1.15 S.F. will not exceed surface temperature of 160 C (320 F) equivalent to Code T3C. C. Class I, Group D, Class II Group F & G listings. E Shunt wound DC motors, 182 through 215 frames, 1/2 through 3 HP, will not exceed surface temperatures of 165 C (329 F) equivalent to Code T3B. U Fractional HP motors in Baldor type 35 will not exceed surface temperatures of 135 C (275 F) equivalent to Code T4. U s 364T through 449T will not exceed surface temperatures of 135 C (275 F) equivalent Code T4. I Fractional HP motors in Baldor type 34, and 1 HP motors and greater built in Baldor type 35, frames 143T through 326T will not exceed surface temperature of 160 C (320 F) equivalent to Code T3C. I Fractional HP motors in Baldor type 34, and permanent magnet DC motors in Baldor type 34 and 35, will not exceed surface temperatures of 160 C (320 F) equivalent to Code T3C. D. Class 1, Group C & D, Class II, Group F & G listings. W Baldor s 182T through 449T will not exceed surface temperatures of 135 C (320 F) Code T4. 4. Not suitable for applications in temperatures below -25 C (-13 F). 5. All Explosion-Proof motors are supplied with Explosion-Proof UL and CSA approved conduit boxes as standard. 6. Baldor AC Explosion Proof, beginning on 71-76, are not approved for use on variable voltage or variable frequency controls. Inverter Duty Explosion Proof motors (page 163) must be used. misapplied in hazardous environments can cause a fire or explosion resulting in destruction of property, serious CAUTION! injury or death. Only the end user or a qualified underwriter is to identify and select the proper class, group, division, and temperature code motor to meet the requirements of each installation. Baldor personnel can advise what listings and approvals Baldor motors carry, but cannot evaluate nor recommend what motors may be suitable for use in hazardous environments. 4

5 Limited Warranty General Information General Information Baldor Electric Company and its employees are proud of our products and are committed to providing our customers and end users with the best designed and manufactured motors, drives and other Baldor products. This Limited Warranty and Service Policy describes Baldor s warranty and warranty procedures. Comments and Questions: We welcome comments and questions regarding our products. Please contact us at: Customer Service: Baldor Electric Company P.O. Box 2400 Fort Smith, Arkansas Facsimile: Website: or refer to page 415 of this catalog for a list of District Offices in your area. Scope of Warranty: All Baldor standard motors are warranted against defects in Baldor workmanship and materials. Warranty Period: Most Baldor products are warranted for 18 months from the date of shipment to Baldor s customer from Baldor s district warehouse or, if applicable, from Baldor s factory. Baldor Standard-E standard efficient motors are warranted for 24 months. Standard-E is limited to three phase, general purpose, HP ratings that fall under the Energy Policy Act (EPAct). Baldor Super-E premium efficient motors are warranted for 36 months. Baldor IEEE841 motors are warranted for 60 months. Baldor commercial motors are warranted for 18 months (see separate warranty statement). Baldor control products are warranted for 24 months. All warranty claims must be submitted to a Baldor Service Center prior to the expiration of the warranty period. Warranty Service Center Locations: Warranty service is available for all Baldor products from Baldor s Customer Service Center in Fort Smith, Arkansas, and from Baldor Authorized Service Centers. A list of Baldor s Authorized Service Centers is available in catalog #505 on CD, Baldor website: and from any Baldor District Office or by contacting us at the above location. Single Phase General Purpose Premium Efficient Super-E Procedure to Receive Warranty Service: Customers should take or ship prepaid the Baldor product requiring warranty service to a Baldor Authorized Service Center. Please include an explanation of the defect or problem, a description of the way in which the Baldor product is used, and your name, address and telephone number. Repair by Other than a Baldor-Authorized Service Center: Customers who are unable to take or ship the Baldor product to a Baldor Authorized Service Center, or who desire a repair to be made by other than a Baldor Authorized Service Center, should contact the local Baldor District Office. A repair by anyone other than a Baldor Authorized Service Center must be approved in advance by Baldor. Repairs or Replacement Within the Scope of the Warranty: If a Baldor product is defective due to Baldor workmanship or materials and the defect occurs during the warranty period, then Baldor will either repair the product or replace it with a new one, whichever Baldor believes to be appropriate under the circumstances. Baldor is not responsible for removal and shipping of the Baldor product to the service center, the reinstallation of the Baldor product upon its return to the customer, or any incidental or consequential damages resulting from the defect, removal, reinstallation, shipment or otherwise. Repairs Outside the Scope of the Warranty: Problems with Baldor products can be due to improper maintenance, faulty installation, non-baldor additions or modifications, or other problems not due to defects in Baldor workmanship or materials. If the Baldor Authorized Service Center determines that the problem with a Baldor product is not due to defects in Baldor workmanship or materials, then the customer will be responsible for the cost of any necessary repairs. Customers not satisfied with a determination that a problem is outside of warranty coverage should contact the Baldor District Office for further consideration. Intended Use: Baldor products are designed for industrial, commercial and agricultural use rather than household, family or personal use. Product Specifications: All product specifications, applications and other information provided in Baldor s catalog and publications are subject to correction and change without notice and should be confirmed with the Baldor District Office prior to ordering. Extended Warranties: Extended warranties are available for certain Baldor products. These warranties are described in Baldor s catalog and other sales literature. Extended warranties are subject to the terms and procedures of this Limited Warranty and Service Policy as modified by the additional terms of the extended warranty. C-Face Industrial Severe Duty Washdown Duty Explosion Proof No Other Warranties and Liability Limitation: This Limited Warranty and Service Policy represents Baldor s sole and exclusive warranty obligation with respect to Baldor products. Baldor s liability to a customer or any other person shall not exceed the Baldor s sales price of the applicable Baldor product. BALDOR DISCLAIMS ALL OTHER EXPRESSED AND IMPLIED WARRANTIES INCLUDING THE IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABILITY. Trademark Notices BALDOR, BALDOR MOTORS AND DRIVES, BALDOR Smart, BALDOR STANDARD-E, BALDOR SUPER-E, BIG RED, DIRTY DUTY, INVERTER DRIVE, ISR, INVERTER SPIKE RESISTANT, MOD EXPRESS, POW R GARD, VALUE FORMULA, and VECTOR DRIVE, and associated designs are registered trademarks of Baldor Electric Company. MATCHED PERFORMANCE, and WASHDOWN DUTY, H2 and associated designs are trademarks of Baldor Electric Company. Baldor has made every effort to make this catalog complete and accurate as of the time of printing. All pricing is subject to change or correction. Since products are continuously being improved, all data is subject to change or correction. The data presented here is for general information to provide an overview of Baldor s capabilities. For specific applications, installation and operating instructions, certified dimensions, capabilities and performance data, and pricing and availability, contact your Baldor District Sales Office listed on page 415. Baldor Electric Company. Pump Commercial 5

6 General Information Commercial Limited Warranty General Information Single Phase General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Baldor Electric Company and its employees are proud of our products and are committed to providing our customers and end users with the best designed and manufactured motors, drives and other Baldor products. This Limited Warranty and Service Policy describes Baldor s warranty and warranty procedures. Comments and Questions: We welcome comments and questions regarding our products. Please contact us at: Customer Service Baldor Electric Company P.O. Box 2400 Fort Smith, Arkansas Facsimile: or refer to page 415 for a list of District Offices in your area. Scope of Warranty: All Baldor commercial motors are warranted against defects in Baldor workmanship and materials. Warranty Period: Baldor commercial motors are warranted for 18 months from the date of shipment to Baldor s customer from Baldor s district warehouse or, if applicable, from Baldor s factory. All warranty claims must be submitted to a Baldor Service Center prior to the expiration of the warranty period. Warranty Service Center Locations: Warranty service is available for all Baldor products from Baldor s Customer Service Center in Fort Smith, Arkansas, and from Baldor Authorized Service Centers. A list of Baldor s Authorized Service Centers is available in catalog #505 from any Baldor District Office or by contacting us at the above location. Procedure to Receive Warranty Service: Customers should take or ship prepaid the Baldor product requiring warranty service to a Baldor Authorized Service Center. Please include an explanation of the defect or problem, a description of the way in which the Baldor product is used, and your name, address and telephone number. Warranty Determinations by Other than a Baldor-Authorized Service Center: Customers who are unable to take or ship the Baldor product to a Baldor Authorized Service Center, or who desire a warranty consideration by other than a Baldor Authorized Service Center, should contact the local Baldor District Office. Baldor must approve warranty considerations by anyone other than a Baldor Authorized Service Center in advance. Replacement Within the Scope of the Warranty: If a Baldor product is defective due to Baldor workmanship or materials and the defect occurs during the warranty period, then Baldor will replace it with a new one. Baldor is not responsible for removal and shipping of the Baldor product to the service center, the reinstallation of the Baldor product upon its return to the customer, or any incidental or consequential damages resulting from the defect, removal, reinstallation, shipment or otherwise. Repairs Outside the Scope of the Warranty: Problems with Baldor products can be due to improper maintenance, faulty installation, non- Baldor additions or modifications, or other problems not due to defects in Baldor workmanship or materials. If the Baldor Authorized Service Center determines that the problem with a Baldor product is not due to defects in Baldor workmanship or materials, then the customer will be responsible for the cost of any necessary repairs. Customers not satisfied with a determination that a problem is outside of warranty coverage should contact the Baldor District Office for further consideration. Intended Use: Baldor commercial motors are designed for commercial and residential use rather than industrial use. Explosion Proof Product Specifications: All product specifications, applications and other information provided in Baldor s catalog and publications are subject to correction and change without notice and should be confirmed with the Baldor District Office prior to ordering. Extended Warranties: Extended warranties are available for certain Baldor products. These warranties are described in Baldor s catalog and other sales literature. Extended warranties are subject to the terms and procedures of this Limited Warranty and Service Policy as modified by the additional terms of the extended warranty. Pump Commercial No Other Warranties and Liability Limitation: This Limited Warranty and Service Policy represents Baldor s sole and exclusive warranty obligation with respect to Baldor products. Baldor s liability to a customer or any other person shall not exceed the Baldor s sales price of the applicable Baldor product. BALDOR DISCLAIMS ALL OTHER EXPRESS AND IMPLIED WARRANTIES INCLUDING THE IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABILITY. Baldor has made every effort to make this catalog complete and accurate as of the time of printing. Since products are continuously being improved, all data is subject to change or correction. The data presented here is for general information to provide an overview of Baldor s capabilities. For specific applications, installation and operating instructions, certified dimensions, capabilities and performance data, and pricing and availability, contact your Baldor District Sales Office, listed on page 415. Baldor Electric Company. 6

7 Baldor Portable Generators Owner Warranty Policy Limited Warranty General Information General Information Baldor will replace or repair free of charge any part or parts of the generator of their manufacture that are defective in workmanship and materials for a period of time as set forth in the Warranty Period chart below. All Baldor products requiring warranty service shall be transported or shipped freight pre-paid, at the risk of the party requiring warranty service, to a Baldor Generator repair facility, or to Baldor Generators Customer Service Department. Written notification of the alleged defect in addition to a description of the manner in which the Baldor generator is used, and the name, address and telephone number of the party requiring warranty service must be included. Baldor is not responsible for removal and shipment of the Baldor product to the service center or for the reinstallation of the Baldor product upon its return to the party requiring warranty service. Problems with Baldor products can be due to improper maintenance, faulty installation, non-baldor additions or modifications, or other problems not due to defects in Baldor workmanship or materials. If a Baldor Generator repair facility determines that the problem with a Baldor product is not due to defects in Baldor workmanship or materials, then the party requesting warranty service will be responsible for the cost of any necessary repairs. EXCEPT FOR THE EXPRESSED WARRANTY SET FORTH ABOVE, BALDOR DISCLAIMS ALL OTHER EXPRESSED AND IMPLIED WARRANTIES INCLUDING THE IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABILITY. NO OTHER WARRANTY, EXPRESSED OR IMPLIED, WHETHER OR NOT SIMILAR IN NATURE TO ANY OTHER WARRANTY PROVIDED HEREIN, SHALL EXIST WITH RESPECT TO THE GOODS SOLD UNDER THE PROVISIONS OF THESE TERMS AND CONDITIONS. ALL OTHER SUCH WARRANTIES ARE HEREBY EXPRESSLY WAIVED BY THE BUYER. UNDER NO CIRCUMSTANCES SHALL BALDOR BE LIABLE OR RESPONSIBLE IN ANY MANNER WHATSOEVER FOR ANY INCIDENTAL, CONSEQUENTIAL OR PUNITIVE DAMAGES, OR ANTICIPATED PROFITS RESULTING FROM THE DEFECT, REMOVAL, REINSTALLATION, SHIPMENT OR OTHERWISE. This is the sole warranty of Baldor and no other affirmations or promises made by Baldor shall be deemed to create an expressed or implied warranty. Baldor has not authorized anyone to make any representations or warranties other than the warranty contained herein. Single Phase General Purpose Premium Efficient Super-E WARRANTY PERIOD Generator Series Labor* Parts C-Face Industrial Portable Products 1 Year 3 Years NO WARRANTY REGISTRATION CARD IS NECESSARY TO OBTAIN WARRANTY ON BALDOR GENERATORS. YOU MUST SAVE THE PURCHASE RECEIPT. PROOF OF PURCHASE DATE SERIAL NUMBER AND MODEL NUMBER WILL BE REQUIRED FOR ALL PORTABLE PRODUCTS TO QUALIFY FOR ANY WARRANTY CONSIDERATION. Severe Duty Commercial Pump Explosion Proof Washdown Duty 7

8 General Information General Information Abbreviations: The Basic Baldor catalog number consists of a letter(s) and four non-significant numbers. A suffix letter(s) and/or number may also be part of the catalog number. For example L3510 or L3510T. Following is a list of prefix and suffix definitions. Prefix: Single Phase General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Explosion Proof Pump Commercial 8 AEM Automotive (GM7EHQ) AF Aeration Fan AM Automotive ( GM7EQ) ANF Auger Flange AO Air-Over AP Subfractional HP, PM AS Arbor Saw B Brake BC DC Speed Control BK Single Phase Gearmotor Kit BLW Blower Kit BMC Brushless DC Control BSM Brushless Servo BTG Tachometer Generator BU Bushing Kit C C-Face with Base CBL Cable Assembly CD Wound Field DC C-Face with Base CDP PM SCR Drive CDPT PM SCR Drive with Integral Tachometer CDPWD Washdown PM SCR Drive, C-Face CDPSWD PM Paint Free Washdown SCR Drive C-Face with base CDPX PM Explosion Proof SCR Drive - C-Face with base CDX Wound Field Explosion Proof DC, C-Face CESWDM Paint Free Super-E Washdown - C-Face with base CF Condenser Fan CHC Direct Drive Fan with Resilient Base CP Chemical Processing, Corrosion Protected CR Crusher CSC Checkout Stand CSM Baldor Smart CSSEWDM All Stainless Super-E Washdown-C-Face with base CSSWDM All Stainless Washdown - C-Face with base CSWDM Paint Free Washdown - C-Face with base CWAM Dirty Duty Washdown - C-Face with base CWDSM Baldor Washdown Smart D DC Shunt or Compound or Definite Purpose Soft Start Control DE Vacuum Pump DG Gate Operator DMG Lifting Magnet Generator DOC Door Operator DR Double Reduction E Super-E Premium Efficiency E3H Super-E Premium Efficiency HVAC Duty with Connection Box located on top of ECP EN FM FCD FD FFC FL G GC GCP GD GF GP GPP GSF GS Super-E Premium Efficiency, Chemical Processing Hostile Environment Encoder Kit F-2 Mount Drip Cover Kit Farm Duty Fan Cover/Conduit Box Kit Flange Kit Subfractional HP Gear Permanent Split Capacitor and Split Phase Permanent Split Capacitor and Split Phase Parallel Shaft Gearmotor Centrifugal Fan 900 Series Reducers Subfractional HP PM PM Parallel Shaft Gear Universal Series Right Angle Gear Reducers Grain Stirring H H3 HP ID IDM IDNM IDWNM IDXM IM IR J JM JP JSL K KN L LRA M M MM MPM MVM N OF P P15 PSC R RBT RES RG RH RL&RM RT S SD SS SWD T TA TM TK UC V VH VJM VLCP VP VPCP WC WD WW ZD ZDM ZDNM ZDWNM Definite Purpose HVAC HVAC Duty with Connection Box located on top of Hydraulic Pump Inverter Control Inverter Drive -TEBC Inverter Drive -TENV Washdown Inverter -TENV Explosion proof Inverter Drive -TEFC Irrigation Drive Instant Reversing Single Phase Farm 56J Stainless Steel Threaded Shaft with Dripcover JM Pump shaft & Face with Base JP Pump shaft & Face with Base Square Flange Pump with threaded shaft. Model 34 Diameter with 56 C-Face, less Base Model 34 Diameter TENV with 56 C-Face, less Base Single Phase Line Reactor Three Phase Multipurpose Soft Start Control Metric Dimension with Base Three Phase Metering Pump Metric Dimension, Flange Mount less Base Totally Enclosed Non ventilated Design D, High Slip (Oil Field) Pressure Washer Pre-Engineered Control Panel Permanent Split Capacitor Repulsion-Start, Induction-Run Roller Bearing Conversion Kit Resolver Feedback Kit Regeneration Resistor Assembly Definite Purpose HVAC Resilient Base(Cradle Mount) Dynamic Braking Resistor Assembly Single Phase Soft Start Series 23H Servo Control All Stainless Washdown Duty Stainless Washdown Duty Torque Control Torque Arm Definite Purpose HVAC with Terminal Panel Endplate Tachometer Mounting Kit Universal Crop Dryer C-Face less Base Vertical Pump, Normal Thrust JM Pump Shaft and Face less Base Vertical Pump, Medium Thrust PM SCR Drive with Metric Face or Flange Vertical Pump, High Thrust West Coast Fit TCZ Washdown Duty Woodworking Vector Control Vector Drive -TEBC Vector Drive -TENV Washdown Vector -TENV Suffix: /240V Field Volt Winding Volt Winding Volt Winding -9 Design C High Torque Winding Leads / Band Diameter / Band Diameter -50 Wound for 50 Hertz Service /4160 Volt Winding A Automatic Thermal Overload BV Blower Vented -C ing includes Class I, Group C -CL Open Chassis Enclosure, Line Regenerative -CO Open Chassis Enclosure, no internal braking E Electric Switch -E 1 Enclosure, built in Dynamic Braking -EL 1 Enclosure, Line Regenerative -EO 1 Enclosure, no internal braking -ER 1 Enclosure, built in Dynamic Braking Transistor -I Explosion-Proof, 1.15 Service Factor M Manual Thermal Overload -MO Protected Chassis Enclosure, no internal braking P Wound Field DC AT -P Partial AC Excludes R- Roller Bearing T "T" Dimension TP Feather Picker TR T -Roller Bearing TS "TS" Short Shaft Pulley Endplate -V12 12 Volt DC -V24 24 Volt DC -W 4 Enclosure -WR Washdown Rating Gear Reducer Suffix: 900 Series A 56C Flange B 140TC Flange C 180TC Flange G Left Hand Output Shaft H Double End Output Shaft J Right Hand Output Shaft Gear Reducer Suffix: Universal Series A 56C or Right Hand Output Shaft B 140TC C 180TC Grinder Suffix: D Deluxe E Exhaust Guards W Wide Design Other Abbreviations: C Permanent Split Capacitor L Capacitor-Start, Induction-Run LC Capacitor-Start, Capacitor-Run S Split Phase X Explosion-Proof Baldor Cross Reference Guide is now a separate catalog. To order use catalog number FM411.

9 Signs and Symbols: information subject to engineering changes after printing, contact Baldor for further information. ~ Drive end bearing pre-loaded on these ratings. Class "F" Insulated. Class "F" Insulated with 1.15 Service Factor or higher that operates within Class "B" temperature limits at rated horsepower. Class "H" Insulated. Q Class I, Group D only, T2C. W Class I, Group C & D, Class II, Group F & G, T4. E Class I, Group D, Class II Group F & G, T3B T Class I, Group C & D only, T3C Y Class I, Group D only, T2A. U Class I, Group D, Class II, Group F & G, T4. I Class I, Group D, Class II, Group F & G, T3C Service Factor. Close-Coupled Pump (JP) suitable for "West Coast Fit". Totally-Enclosed, Non-Ventilated, Continuous Duty. + Brake suitable for vertical mounting with brake above or below. Brake suitable for vertical mounting with brake below motor only. Agri-Duty, Capacitor-Start, Induction-Run. Repulsion-Start Induction-Run rated 10 hp continuous duty, 15 HP one hour duty. # Resilient Mount Single Phase with moderate starting torque for fan applications. SCR with a 3:1 constant torque speed range. Shown as WP1 enclosure. 50/60 Hz Baldor Super-E Premium Efficient electric motors meet or exceed the Premium efficiency specifications. Insulation Class: Absence of symbol(s) adjacent to the catalog number generally indicates the motor is insulated with Class B or better materials and will not exceed Class B temperature rise at rated nameplate horsepower. Exceptions occur in DC and Special Purpose. Contact a Baldor representative for information on a particular motor. General Information Authorized Service Centers and Service Policy Baldor CD Rom and website: have a listing of Baldor s United States and Canadian network of factory authorized service centers. Supplements are also available listing International service centers. Dimensions Baldor CD Rom and website: lists dimensions for all stock AC and DC motor ratings. Efficiencies All efficiencies listed are nominal efficiencies at full load. Amps FLA - For low voltage amps, double high voltage amps shown. Voltage/Power Service: Voltage Code A / Volts, 60 HZ B /230 Volts, 60 HZ B /230 Volts, Usable at 208 Volts, 60 HZ C Volts, 60 HZ D Volts, 60 HZ D Volts, Usable at 208 Volts, 60 Hz E /460 Volts, 60 HZ E /460 Volts, Usable at 208 Volts, 60 HZ E /460Volts, Usable at 200 Volts, 60 HZ F /460 Volts, 60 HZ F /460 Volt, DOL or Wye Start, Delta Run, 60 HZ G Volts, 60 HZ G Volt, DOL or Wye Start, Delta Run, 60 HZ H Volts, 60 HZ I...200Volts, 60 HZ I Volts, DOL or Part Winding Start, 60 HZ J /220 Volts, 50 HZ K /380/440 Volts, 50 HZ L Volts, 60 HZ M Volts, 50 HZ N...380//460 Volts, 50//60 HZ O /4160 Volts, 60 HZ P /400 Volts, 50 HZ Q Volts, HZ R Volts, 50 HZ S /415 Volts, 50 HZ T /380// /460 Volts, 50//60 HZ U /380//230/460 Volts, 50//60 HZ V /460/796 Volts, 60 HZ V /796 Volts, 60 HZ W Volts DOL or Wye Start, Delta Run, 50 HZ Y Volts, 60 HZ General Information Single Phase General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Modified Details of Baldor s Mod Express Program are listed in this catalog. Using stock motors, Baldor can modify motors to fit a variety of applications in only 2 to 5 working days for most modifications. New Stock Items Red catalog numbers represent new items added this printing. Performance and connection diagrams Baldor CD-ROM lists performance test data and connection diagrams for all stock AC and DC motor ratings. Explosion Proof Renewal Parts and Installation - Maintenance Data Data Section 506 contains a wide variety of the most commonly required service parts. AC (MN400) and DC (MN605) motor installation and maintenance data are also available. SCR Drive Field Amps listed are for High Voltage Connections with motor at operating temperature. Service Factor T-frames in TEFC construction have a service factor of 1.15 or greater except where noted. All U- frame TEFC motors (except explosion-proof) have open service factors. Fractional horsepower TEFC motors have open service factors. All DC motors have 1.0 service factors. Freight Policy Shipments of stock products shown in this catalog are made with the selling terms of F.O.B. factory, Fort Smith Distribution Center, or a Baldor District Warehouse. International Shipments - Ex Works, Non-stock items - FOB Factory. Baldor will prepay and absorb freight charges, on a carrier chosen by Baldor, to the first destination in the continental United States on shipments of 1000 pounds (500 pound on grinders and buffers) or more. Exceptions may apply on shipments of certain stock products. Contact your Baldor District Office for these exceptions. Pump Commercial 9

10 General Information Single Phase Single Phase - TEFC, Rigid Base Single Phase 1/12 thru thru 256T Applications: Compressors, pumps, fans, farm equipment, conveyors, material handling equipment, machine tools and others. Features: Heavy gauge steel frames and a heavy duty base seam welded to the frame, ball bearings, a "Snap Action" starting switch and gasketed conduit box and capacitor cover. General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Explosion Proof Pump Commercial 60 Hz. NOTE: types with suffix L denote capacitor start, induction run. types with suffix LC denote capacitor start, capacitor run (two value capacitor). Baldor 56H frames will also mount as 56, 143T and 145T frames with 56 frame shaft dimensions. 60 HZ: B = 115/230, B1= 115/230 usable at 208 volts. See notes on pages 8 and 9, and inside back flap. Type C Dimension 1/ L K 3310L B / L K 3310L B / L K 3313L B / L K 3313L B / L K 3316L B / L K 3408L B / L K 3418L B / L K 3316L B / EL K 3414LC B 1.3 1/ L K 3411L B / L3403M 245 K 3411L B / L K 3421L B / L K 3516L B / L K 3413L B / L K 3414L B / L3406M 269 K 3414L B / EL K 3418LC B 1.6 1/ L K 3414L B / L3501M 269 K 3414L B / L K 3424L B / L K 3424L B / L K 3413L B / L K 3413L B / L K 3421L B / L3409M 316 K 3421L B / EL K 3424LC B 2.3 1/ L K 3421L B / L3504M 316 K 3421L B / L3504A 321 K 3421L B / /56H L K 3528L B / L K 3424L B / EL K 3528LC B 3.2 3/ L K 3428LC B / L3507M 372 K 3428LC B / L3507A 389 K 3428LC B / /56H L K 3528LC B / T L3508T 581 L1 3528LC B1 5.0 Volt Code Amps 10

11 Single Phase - TEFC, Rigid Base continued Single Phase General Information 60 Hz. Type NOTE: types with suffix L denote capacitor start, induction run. types with suffix LC denote capacitor start, capacitor run (two value capacitor). Baldor 56H frames will also mount as 56, 143T and 145T frames with 56 frame shaft dimensions. Baldor 56HZ frames will also mount as 145T frame with 145T frame shaft dimensions. 60 Hz: B= 115/230, B1= 115/230 usable at 208 volts, C=230 volts, D1=230 usable at 208 = L3712T has cooling fan on each end. See notes on pages 8 and 9, and inside back flap. C Dimension /56H L K 3520L B /56H L3509M 339 K 3524L B H EL K 3532LC B /56H L K 3524L B /56H L3510M 422 K 3524L B /56H L3510A 437 K 3524L B T L3510T 358 L1 3524L B T L3510TM 422 L1 3524L B L L1 3620L B L L1 3634L B / /56H L K 3524L B / /56H L3513M 461 K 3528L B / T L3513T 395 L1 3524L B / H EL K 3540LC B / /56H L K 3532LC B / /56H L3514M 477 K 3532LC B / /56H L3514A 518 K 3532LC B / T EL3514T 548 L1 3540LC B / T L3514T 407 L1 3532LC B / T L3514TM 477 L1 3532LC B / L L1 3628L B / T L3613T 1081 L1 3634LC B /56H L K 3535L B /56H L3515M 539 K 3535L B T L3515T 446 L1 3535L B HZ L3516TM 679 K 3535LC C T EL3605T 749 L1 3623LC B T L3605T 589 L1 3628L B T L3605TM 719 L1 3634L B L L1 3628L B L3605M 826 L1 3628L B L L1 3735LC B T L3606T 608 L1 3634L B L L1 3634L B T EL3609T 874 L1 3640LC C T L3609T 694 L1 3634LC B T L3609TM 750 L1 3634LC B L L1 3735LC B L L1 3744LC B T L3608T 838 L1 3640LC C T L3608TM 864 L1 3640LC C T L3612TM 872 L1 3646LC C T EL3612T 1044 L1 3646LC C T L3708T 828 L1 3735LC D T L3708TM 973 L1 3744LC C L L1 3744LC D / T L3709T 1079 L1 3735LC D / T L3710T 1094 L1 3744LC D T L3711T 1325 L1 3744LC C T 1343 L1 3750LC C T L1177T 3830 L1 0956LC C 70.0 Volt Code Amps SHADED RATINGS ARE CAST IRON FRAMES Single Phase General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Explosion Proof Pump Commercial 11

12 General Information Single Phase Single Phase - ODP, Rigid Base Single Phase 1/6 thru thru 215T Applications: Compressors, pumps, conveyors, machine tools, air handling, and others. Features: Copper windings, dynamically balanced rotors, ball bearings, heavy gauge steel frames, and other industrial quality features. General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Explosion Proof Pump Commercial 60 Hz. NOTE: Baldor 56H frames will also mount as 56, 143T and 145T frames with 56 frame shaft dimensions. 60 Hz: B= 115/230 volts, B1= 115/230 usable at 208 volts. See notes on pages 8 and 9, and inside back flap. Type C Dimension 1/ L K 3408L B / L K 3418L B / EL K 3414LC B 1.3 1/ L K 3411L B / L1203M 212 K 3411L B / L K 3421L B / L K 3421L B / L K 3413L B / L K 3414L B / L1206M 238 K 3414L B / EL K 3418LC B 1.6 1/ L K 3414L B / L1301M 250 K 3414L B / L K 3424L B / L K 3424L B / L K 3416L B / L K 3413L B / L K 3418L B / L1209M 296 K 3418L B / EL K 3424LC B 2.3 1/ L K 3418L B / L1304M 296 K 3418L B / L1304A 281 K 3418L B / /56H L K 3524L B / L K 3420L B / L1306A 247 K 3516L B 4.9 3/ EL K 3524LC B 3.3 3/ L K 3428L B / L1307M 352 K 3428L B / L1307A 343 K 3428L B / /56H L K 3528LC B L K 3428L B L1309A 262 K 3428L B EL K 3528LC B L K 3520L B /56H L1310M 409 K 3520L B /56H L K 3528L B /56H L1318M 381 K 3528L B T L1318T 364 L1 3528L B T L1318TM 381 L1 3528L B 6.2 Volt Code Amps 12

13 Single Phase - ODP, Rigid Base continued Single Phase General Information 60 Hz. NOTE: Baldor 56H frames will also mount as 56, 143T and 145T frames with 56 frame shaft dimensions. 60 Hz: B= 115/230, B1= 115/230 usable at 208 volts, C= 230, D1=230 usable at 208 volts. See notes on pages 8 and 9, and inside back flap. Type C Dimension L L1 3617L B L1401M 550 L1 3617L B L L1 3628L B / H L K 3428LC B / /56H L1313A 352 K 3524L B / T L1313T 346 L1 3520L B / H EL K 3535LC B / /56H L K 3528L B / /56H L1319M 460 K 3528L B / T EL1319T 565 L1 3535LC B / T L1319T 390 L1 3528L B / T L1321T 468 L1 3535L B / T L1321TM 507 L1 3535L B / L L1 3623L B / L1403M 600 L1 3623L B /56H L K 3528L B /56H L1317A 473 K 3528L B T L1320T 494 L1 3528LC B T L1322T 477 L1 3532LC B T L1322TM 519 L1 3532LC B T EL1405T 639 L1 3623LC B T L1405T 489 L1 3628L B L L1 3628L B L L1 3720L B L L1 3729L B T L1406T 561 L1 3628L B T EL1408T 667 L1 3634LC C T L1408T 529 L1 3634LC B T L1408TM 624 L1 3634LC B L L1 3729L B L L1 3735LC B T L1409T 668 L1 3634L D T EL1410T 763 L1 3646LC C T L1410T 634 L1 3640LC D T L1410TM 759 L1 3640LC D T L1430T 575 L1 3634LC D T L1430TM 759 L1 3634LC D T L1508T 828 L1 3735L D / T L1509T 1033 L1 3640LC D / T L1510T 899 L1 3744LC D T L1511T 1304 L1 3740L D T L1512T 1314 L1 3744LC C 42.0 Volt Code Amps Single Phase General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Explosion Proof Commercial Pump 13

14 General Information Single Phase Three Phase - TEFC and TENV, Rigid Base General Purpose Industrial 1/8 thru 500 General Purpose 42 thru 5011L Applications: Pumps, compressors, fans, conveyors, machine tools and other general purpose three phase applications. Features: Suitable for mounting in any position. Ball bearings, heavy gauge steel and cast iron frames, and gasketed conduit boxes. EM and ECP Super-E motors have Premium efficiency and 3 year warranty. General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Explosion Proof Pump Commercial 60 Hz. Type NOTE: Baldor 56H frames will also mount as 56, 143T and 145T frames with 56 frame shaft dimensions. 60 HZ: E = /460 volts, E1=230/460 volts usable at 208 volts. See notes on pages 8 and 9, and inside back flap. C Dimension 1/ M K 3313M E / M K 3316M E / M K 3408M E / M K 3410M E / NM K 3413M E / M K 3411M E / M K 3411M E / M K 3516M E / M K 3410M E / M K 3413M E / M LS 3413M E / NM K 3416M E / M K 3414M E / M K 3520M E / M K 3410M E / M K 3410M E / M K 3416M E / M LS 3416M E / NM K 3420M E / M K 3418M E / /56H M K 3524M E 1.3 1/ M L1 3524M E 1.3 3/ M K 3413M E / M K 3413M E / M K 3420M E 1.5 3/ M LS 3420M E 1.5 3/ NM K 3520M E / /56H M K 3524M E 1.4 3/ T M3543T 389 L1 3428M E 1.5 3/ M L1 3524M E 1.4 3/ M L1 3535M E EM K 3516M F M K 3416M E EM K 3524M E M LS 3426M E T EM3546T 446 LS 3524M E T M3546T 314 LS 3518M E T NM3546T 340 L1 3524M E T EM3581T 575 L1 0524M E T M3581T 438 L1 0518M E M L1 3516M E 1.7 Volt Code Amps SHADED RATINGS ARE CAST IRON FRAMES 14

15 Three Phase - TEFC, Rigid Base continued General Purpose Industrial General Information 60 Hz. Type NOTE: Baldor 56H frames will also mount as 56, 143T and 145T frames with 56 frame shaft dimensions. 60 Hz: E = /460 volts, F=230/460 volts. See notes on pages 8 and 9, and inside back flap.. C Dimension EM K 3528M E /56H M K 3524M E T M3556T 428 L1 3526M E T EM3582T 643 L1 0528M F T M3582T 578 L1 0526M E M L1 3524M E T M3617T 789 L1 3623M F / EM K 3524M E / M K 3424M E / T EM3550T 456 L1 3524M E / T M3550T 355 L1 3520M E / T EM3583T 524 L1 0524M E / T M3583T 471 L1 0520M E / M L1 3516M E / EM K 3528M F / M LS 3520M E / T EM3554T 463 LS 3528M F / T M3554T 321 LS 3524M E / T NM3554T 355 L1 3535M E / T EM3584T 595 L1 0528M E / T M3584T 447 L1 0524M E / M L1 3520M E / /56H M K 3528M F / T M3607T 494 L1 3628M E / T EM3667T 766 L1 0634M E / T M3667T 634 L1 0625M E / M L1 3528M F / T M3618T 934 L1 3628M F / M L1 3720M E EM K 3532M E H M K 3428M E T EM3555T 500 L1 3532M E T M3555T 409 L1 3526M E T EM3586T 596 L1 0532M E T M3586T 531 L1 0526M E M L1 3524M E EM K 3532M E /56H M LS 3528M E T EM3558T 480 LS 3532M E T M3558T 338 LS 3528M E T EM3587T 624 L1 0532M E T M3587T 485 L1 0528M E M L1 3528M E T M3614T 531 L1 3632M E T EM3664T 778 L1 0640M E T M3664T 678 L1 0632M E M L1 3628M E T M3702T 1185 L1 3726M E M L1 3726M E /56H M K 3528M E T M3559T 469 L1 3535M E 3.7 Volt Code Amps SHADED RATINGS ARE CAST IRON FRAMES Single Phase General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Explosion Proof Pump Commercial 15

16 General Information Single Phase General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Explosion Proof Pump Commercial 16 Three Phase - TEFC, Rigid Base continued 60 Hz. NOTE: Baldor 56H frames will also mount as 56, 143T and 145T frames with 56 frame shaft dimensions. 60 Hz: E = /460 volts, E1=230/460 volts usable at 208 volts, F=230/460 volts. See notes on pages 8 and 9, and inside back flap. General Purpose Industrial Type C Dimension T EM3660T 689 L1 0628M F T M3660T 635 L1 0623M E T EM3610T 554 L1 3628M F T M3610T 499 L1 3535M E M L1 3528M E T EM3661T 708 L1 0628M E T M3661T 638 LS 0628M E T EM3611T 531 LS 3628M E T M3611T 398 LS 3546M E T M3611T/ L1 3628M E M L1 3535M E M L1 3623M E T EM3764T 970 L1 0736M E T EM3704T 848 L1 3736M E T M3704T 669 L1 3729M E M L1 3726M E T M3764T 889 L1 0729M E T M3705T 1295 L1 3735M F T EM3663T 848 L1 0634M F T M3663T 785 L1 0630M E T EM3613T 615 L1 3634M F T M3613T 574 L1 3630M E M L1 3628M E T EM3665T 709 L1 0643M E T M3665T 648 L1 0638M E T EM3615T 581 LS 3643M E T M3615T 458 LS 3634M E M L1 3634M E T EM3768T 1126 L1 0744M E T M3768T 984 L1 0735M E T EM3708T 959 L1 3744M E T M3708T 805 L1 3735M E U M L1 0744M E T M2280T 2062 L1 0928M E / T M3616T 698 L1 3640M E / T EM3769T 982 L1 0733M E / T M3769T 894 L1 0728M E / T EM3709T 922 L1 3733M F / T M3709T 846 L1 3640M E / M L1 3640M E / T EM3770T 946 L1 0740M E / T M3770T 865 L1 0735M E / T EM3710T 838 LS 3744M E / T M3710T 585 LS 3735M E / U M L1 0735M E / T EM2276T 1605 L1 0954M E / T M2276T 1201 L1 0760M E / U M L1 0740M F / T M2401T 2273 L1 0940M E T EM3771T 1152 L1 0744M E T M3771T 1074 L1 0732M F T EM3711T 935 L1 3744M E Volt Code Amps SHADED RATINGS ARE CAST IRON FRAMES

17 Three Phase - TEFC, Rigid Base continued General Purpose Industrial General Information 60 Hz. Type NOTE: 60 Hz: E= /460 Volts, 60 Hz, E1=230/460 Volts usable at 208 Volts, F=230/460 Volts, F2=230/460 Volt, DOL or Wye Start, Delta Run, See notes on pages 8 and 9, and inside back flap. C Dimension T M3711T 886 L1 3732M E U M L1 0735M E T EM3774T 1062 L1 0750M E T M3774T 931 L1 0740M E T EM3714T 947 LS 3750M E T M3714T 712 LS 3740M E U M L1 0736M E T EM2332T 1833 L1 0960M E T M2332T 1337 L1 0946M E U M L1 0936M E T M2402T 2641 L1 1028M E T EM2394T 1587 L1 0934M E T M3713T 1125 L1 3750M E T M2394T 1402 L1 0750M E U M L1 0744M E T EM2333T 1460 LS 0936M E T M2333T 1250 LS 0756M F U M L1 0932M E T EM4100T 2445 L1 1054M E T M4100T 2133 L1 1036M E T M2395T 3672 L1 1040M E T EM4106T 1742 L1 0944M E T M4106T 1540 L1 0750M E U M L1 0932M E T EM2334T 1770 LS 0952M E T M2334T 1510 LS 0938M E T M2334T L1 0938M F U M L1 0938M E T EM4102T 3256 L1 1060M E T M4102T 2577 L1 1042M E T M4112T 4175 L1 1238M E T M4118T 1745 L1 0942M E TS EM4107T 2273 L1 0950M E TS M4107T 1959 L1 0942M E U M L1 1232M E T EM4103T 2316 LS 1046M E T M4103T 1868 LS 0956M E T M4103T L1 0956M F U M L1 1234M E T EM4111T 3684 L1 1080M F T M4111T 3110 L1 1072M E T M4116T 5158 L1 1246M E TS EM4108T 2702 L1 0954M E TS M4108T 2126 L1 0954M E T EM4104T 2748 LS 1060M E T M4104T 2207 LS 0964M E T M4104T L1 0964M F U M L1 1240M E T EM4117T 4256 L1 1260M E T M4117T 3772 L1 1080M E T M4338T 5621 D3 1442M E Volt Code Amps SHADED RATINGS ARE CAST IRON FRAMES Single Phase General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Explosion Proof Pump Commercial 17

18 General Information Single Phase General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Explosion Proof Pump Commercial 18 Three Phase - TEFC, Rigid Base continued 60 Hz. General Purpose Industrial NOTE: 60 Hz: E1=230/460 volts usable at 208 volts, F=230/460, SHADED RATINGS ARE CAST IRON FRAMES F2= 230/460 volts, DOL or Wye Start, Delta Run, G=460 volts, G2= 460 volts, DOL or Wye Start, Delta Run. See notes on pages 8 and 9, and inside back flap. Custom TEFC motors available through 900 ; Open and WPII motors through Contact your Baldor Sales Representative. Type C Dimension TS EM4109T 3500 L1 1244M E TS M4109T 3039 L1 1050M E T EM4110T 3594 LS 1260M E T M4110T 2928 LS 1068M E T M4110T L1 1248M F U M L1 1440M F T EM4308T 5304 L1 1468M F T M4308T 4180 L1 1464M E T M4348T 7116 L1 1454M E TS EM4114T 4052 L1 1252M E TS M4114T 3089 L1 1064M E T EM4115T 3928 LS 1266M E T M4115T 3031 LS 1080M E T M4115T L1 1254M F TS M4115TS 3077 LS 1080M E U M L1 1446M E T EM4312T 6410 L1 1474M E T M4312T 5304 L1 1456M E T M4458T 8563 D3 1656M E TS EM4310T 5693 L1 1458M E TS M4310T 4714 L1 1450M E T EM4314T 5653 LS 1462M E T M4314T 4644 LS 1454M E T M4314T L1 1454M F TS M4314TS 4644 LS 1454M E T EM4403T 7625 D3 1672M F T M4403T 6562 D3 1484M F T M4468T 9889 D3 1666M E TS EM4313T 6624 L1 1472M F TS M4313T 5725 L1 1456M E T EM4316T 6610 LS 1482M E T M4316T 5725 LS 1476M E T M4316T L1 1462M F TS M4316TS 5725 LS 1470M E T EM4404T 8879 D3 1680M E T M4404T 7402 D3 1678M E TS ECP4402T D3 1664M G TS M4402T D3 1472M G T ECP4400T LS 1684M G T M4400T 7109 LS 1480M F T M4400T L1 1480M F TS M4400TS 7109 LS 1480M F T ECP4409T D3 1888M G T M4409T 9252 D3 1868M F TS ECP4412T D3 1852M G TS M4412T D3 1860M G T ECP4410T LS 1876M G T M4410T LS 1868M G TS M4410TS LS 1868M G T ECP4411T D M G T M4411T D3 1872M G Volt Code Amps

19 Three Phase - TEFC, Rigid Base continued 60 Hz. General Purpose Industrial NOTE: 60 Hz: G=460 volt, G2=460 volts, DOL or Wye Start, Delta Run, O=2300/4160 volts. SHADED RATINGS ARE CAST IRON FRAMES with 449TY, 5007ST, 5011SY and 5011LY have non-standard BA due to drive end bearing cooling fan. Please refer to layout drawing See notes on pages 8 and 9, and inside back flap. ECP4408T-4, ECP44304T-4, ECP44306T-4, ECP44354T-4 and ECP44404T-4 do not meet Premium efficiency. A custom motor is available. Type C Dimension TS ECP4413T D3 1856M G TS M4413T D3 1856M G T ECP4406T LS 1888M G T M4406T LS 1884M G TS M4406TS LS 1884M G T ECP44156T D M G T M44156T D M G TS ECP4416T D3 1876M G TS M4416T D3 1876M G TS ECP44202T D M O T ECP4407T LS 18136M G T ECP44204T D M O T M4407T LS 18112M G TS M4407TS LS 18112M G T ECP44206T D M G T M44206T D M G TS ECP44252T D M G SY ECP50252S D M O TS M44252T D3 1888M G T ECP4408T LS 18168M G L ECP50254L D M O T M4408T LS 18136M G TS M4408TS LS 18136M G TY ECP44256T D M G L ECP50256L D M O TY M44256T D M G TS ECP44302T D M G SY ECP50302S D M O TS M44302T D M G TY ECP44304T LS 18160M G L ECP50304L D M O T M44304T LS 18152M G TS M44304TS LS 18152M G LY ECP50306L D M O TY M44306T D M G TS ECP44352T D M G TS M44352T D M G TY ECP44354T LS 18168M G LY ECP50354L D M O T M44354T LS 18168M G TS M44354TS LS 18168M G LY ECP50356L D M G LY ECP50356L D M O L M50356L D M G TS ECP44402T D M G SY ECP50402S D M O TS M44402T D M G TY ECP44404T LS 18180M G LY ECP50404L D M O T M44404T LS 18180M G TS M44404TS LS 18180M G LY ECP50406L D M O 52.0 Volt Code Amps General Information Single Phase General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Explosion Proof Pump Commercial 19

20 General Information Three Phase - TEFC, Rigid Base continued General Purpose Industrial Single Phase General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty 60 Hz. NOTE: 60 Hz: G=460, G2= 460, 6 lead, DOL or Wye Start, Delta Run, O=2300/4160 volts. SHADED RATINGS ARE CAST IRON FRAMES Suffix TR indicates motor has roller bearing suitable for belted loads only. All motors 449T through 5011L frame have ball bearings suitable for coupled loads. If load is belted, a roller bearing may be required. Contact your local Baldor office. with 449TY, 5009ST, 5011SY and 5011LY have non-standard BA due to drive end bearing cooling fan. Please refer to layout drawing. See notes on pages 8 and 9, and inside back flap. ECP4408TR-4, ECP44304TR-4, ECP44306TR-4 do not meet Premium efficiency. A custom motor is available. Three Phase - ODP, Rigid Base Type C Dimension LY ECP50454L D M O LY ECP50456L D M O SY M50502S D M G SY ECP50502S D M O L M50504L D M G LY ECP50504L D M O LY ECP50506L D M O 65.0 with Roller Bearings T ECP44156TR D M G T ECP4407TR D M G TY ECP44206TR D M G TY ECP4408TR D M G TY ECP44256TR D M G TY ECP44304TR D M G Volt Code 1/4 thru 600 General Purpose 48 thru 5009L Applications: Pumps, compressors, fans, conveyors, machine tools and other general three phase applications. Amps Washdown Duty Explosion Proof Pump Commercial 60 Hz. Features: Copper windings, ball bearings and heavy duty steel or cast iron frames. Mount in any position. EM Super-E motors have Premium efficiency and 3 year warranty. NOTE: Baldor 56H frames will also mount as 56, 143T and 145T frames with 56 frame shaft dimensions. 60 Hz: E1=230/460 volts usable at 208 volts. See notes on pages 8 and 9, and inside back flap. Type C Dimension 1/ M K 3410M E / M K 3411M E / M K 3411M E / M K 3410M E / M K 3413M E / M LS 3413M E / M K 3414M E / M K 3414M E / M K 3410M E / M K 3410M E / M K 3416M E / M LS 3416M E / M3108A 301 K 3416M E / M K 3418M E1 1.2 Volt Code Amps 20

21 Three Phase - ODP, Rigid Base continued General Purpose Industrial General Information 60 Hz. NOTE: Baldor 56H frames will also mount as 56, 143T and 145T frames with 56 frame shaft dimensions. 60 Hz: E= /460 Volts, E1=230/460 volts usable at 208 volts, F= 230/460 volts. See notes on pages 8 and 9, and inside back flap. Type C Dimension 1/ M K 3418M E / M K 3524M E 1.3 3/ M K 3413M E / M K 3413M E / M K 3420M E 1.5 3/ M LS 3420M E 1.5 3/ M3112A 329 K 3420M E / M K 3428M E 1.5 3/ T M3153T 347 L1 3428M E EM K 3516M E M K 3416M E M LS 3424M E M3116A 366 K 3424M E T EM3116T 389 L1 3520M E T M3116T 282 LS 3518M E M L1 3516M E /56H M K 3524M E T EM3156T 457 L1 3528M F T M3156T 396 L1 3528M E T M3216T 675 L1 3623M F / M K 3424M E / T EM3120T 384 L1 3520M E / T M3120T 331 L1 3518M E / M LS 3520M E / M3154A 365 K 3520M E / T EM3154T 408 L1 3526M E / T M3154T 300 LS 3524M E / M L1 3520M E / /56H M K 3528M F / T EM3207T 535 L1 3632M E / T M3207T 465 L1 3625M E / T M3220T 821 L1 3628M F M K 3428M E T EM3155T 450 L1 3524M E T M3155T 367 L1 3522M E M L1 3520M E /56H M LS 3524M E T EM3157T 436 L1 3532M E T M3157T 323 LS 3526M E HZ M3157TA 419 K 3524M E M L1 3524M E T EM3215T 547 L1 3640M E T M3215T 456 L1 3628M E T M3303T 1014 L1 3726M E /56H M K 3524M E T EM3158T 457 L1 3535M E T M3158T 390 L1 3528M E M L1 3524M E T M3161T 401 L1 3540M E HZ M3161TA 465 K 3540M E T EM3211T 471 L1 3628M E T M3211T 352 LS 3540M E 4.0 Volt Code Amps Single Phase General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Explosion Proof Pump Commercial 21

22 General Information Single Phase General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Explosion Proof Pump Commercial 22 Three Phase - ODP, Rigid Base continued 60 Hz. General Purpose Industrial NOTE: Baldor 56H frames will also mount as 56, 143T and 145T frames with 56 frame shaft dimensions. Baldor 56Hz frames will also mount as 56, 143T and 145T frames with 143T-145T frame shaft dimensions. 60 Hz: E = /460 Volts, 60 Hz, E1= 230/460 volts usable at 208 volts, F= 230/460 volts, F2=230/460 volt, DOL or wye start, delta run. See notes on pages 8 and 9, and inside back flap. Type C Dimension T M3211T/ L1 3625M E T M3211TA 491 L1 3540M E M L1 3535M E M L1 3623M E T EM3305T 696 L1 3735M E T M3305T 535 L1 3729M E T M3306T 1168 L1 3735M F T EM3212T 499 L1 3634M F T M3212T 403 L1 3535M F M L1 3623M E T EM3218T 516 L1 3632M E T M3218T 389 LS 3628M E T M3218TA 519 L1 3630M E M L1 3625M E T EM3309T 912 L1 3740M E T M3309T 702 L1 3735M E T M2504T 1634 L1 3734M F / T EM3219T 793 L1 3640M F / T M3219T 554 L1 3630M E / M L1 3628M E / T EM3311T 759 L1 3732M E / T M3311T 553 LS 3646M E / U M L1 3726M E / T EM2506T 1095 L1 3956M E / T M2506T 867 L1 3750M E / T M2508T 2045 L1 3938M E T EM3312T 906 L1 3736M E T M3312T 696 L1 3725M E T EM3313T 919 L1 3744M E T M3313T 677 LS 3738M E U M L1 3924M E T EM2511T 1424 L1 3954M E T M2511T 1121 L1 3952M E T EM3314T 1288 L1 3744M E T M3314T 1017 L1 3735M E T EM2513T 1303 L1 3938M E T M2513T 1024 LS 3752M E U M L1 3932M E T EM2524T 1922 L1 4050M F T M2524T 1467 L1 3958M E T EM2514T 1513 L1 3932M E T M2514T 1301 L1 3930M E T EM2515T 1636 L1 3944M E T M2515T 1313 L1 3936M E T M2515T L1 3936M F U M L1 3940M E T EM2528T 2340 L1 4056M E T M2528T 1800 L1 3970M E T EM2516T 1817 L1 3940M E T M2516T 1574 L1 3934M E T EM2531T 1994 L1 4046M E T M2531T 1591 L1 3942M E Volt Code Amps

23 Three Phase - ODP, Rigid Base continued General Purpose Industrial General Information 60 Hz. NOTE: 60 Hz: E1=230/460 usable at 208 volts, F = 230/460, F2 = 230/460 volts, usable at 208 volts, G2=460 volt, DOL or Wye Start, Delta Run. See notes on pages 8 and 9, and inside back flap. Type C Dimension T M2531T L1 3942M F U M L1 4044M E T EM2532T 2826 L1 4252M E T M2532T 2529 L1 4064M E TS EM2534T 2144 L1 4040M F TS M2534T 1667 L1 3938M E T EM2535T 2181 L1 4052M E T M2535T 1860 L1 3954M E T M2535T L1 3952M F U M L1 4046M F T EM2536T 2948 L1 4268M E T M2536T 2665 L1 4076M E TS EM2538T 2763 L1 4054M F TS M2538T 2347 L1 3950M E T EM2539T 2846 L1 4250M E T M2539T 2372 L1 4052M E T M2539T L1 4052M F T EM2540T 4201 L1 1458M E T M2540T 3912 L1 4268M E TS EM2542T 3010 L1 4058M F TS M2542T 2432 L1 4044M E T EM2543T 3141 L1 4256M E T M2543T 2785 L1 4068M E T M2543T L1 4060M F TS M2543TS L1 4068M F T EM2544T 5085 L1 1466M E T M2544T 4709 L1 4272M E TS EM2546T 3808 L1 4252M F TS M2546T 3398 L1 4054M F T EM2547T 3954 L1 4278M E TS M2547TS L1 4252M F T M2547T 3436 L1 4252M E T M2547T L1 4252M F T EM2548T D3 1666M G T M2548T 5492 D3 4466M E TS EM2549T 4996 L1 4254M F TS M2549T 4055 L1 4248M E T EM2551T 4854 L1 4462M F T M2551T 4217 L1 4272M E T M2551T L1 4272M F TS M2551TS L1 4272M F T EM2552T D3 1672M G T M2552T 6485 D3 4478M E TS EM2550T 5341 L1 4264M F TS M2550T 4585 L1 4260M E T EM2555T D3 4476M G T M2555T 4604 D3 4464M E T M2555T D3 4464M F TS M2555TS D3 4464M F T EM2583T D3 1860M G T M2583T 7011 D3 1852M F Volt Code Amps SHADED RATINGS ARE CAST IRON FRAMES Single Phase General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Explosion Proof Pump Commercial 23

24 General Information Single Phase General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Explosion Proof Pump Commercial Three Phase - ODP, Rigid Base continued 60 Hz. General Purpose Industrial NOTE: 5000 frame motors are WPI. SHADED RATINGS ARE CAST IRON FRAMES 60 Hz: G = 460, G2=460, 6 lead, DOL or Wye Start, Delta Run, G2=460 volt, DOL or Wye Start, Delta Run, O= 2300/4160 volts. See notes on pages 8 and 9, and inside back flap. Custom TEFC motors available through 900 ; Open and WPII motors through Contact your Baldor Sales Representative. * Foot also drilled for 447T frame mounting. Type C Dimension TS EM2554T D3 4464M G TS M2554T D3 4450M G T EM2559T D3 4488M G T M2559T D3 4486M G TS M2559TS D3 4486M G T EM2557T D3 1884M G T M2557T D3 1856M G TS EM2556T D3 4472M G TS M2556T D3 4458M G T EM2558T D3 1868M G T M2558T D3 1864M G TS M2558TS D3 1864M G T EM2560T D3 1896M G T M2560T D3 1872M G TS EM2562T D3 1860M G TS M2562T D3 1852M G T EM2563T D3 1880M G T M2563T D3 1880M G T EM2564T D M G T M2564T D3 1884M G TS M2565T D3 1856M G T EM2566T D3 1892M G T M2566T D3 1880M G TS M2568T D3 1864M G TS M25302S D M O T EM2569T D M G T M2569T D3 1888M G L M25304L D3 2097M O TS M2571T D3 1868M G TS * M25352T D3 1868M G T M2572T D M G TS * M25402T D3 1888M G T * M25404T D M G L M25404L D M O TS * M25452T D3 1896M G T * M25454T D M G S M25502S D M G L M25504L D M G L M25504L D M O S M25602S D M G S M25602S D M O L M25604L D M G L M25604L D M O 76.0 Volt Code Amps 24

25 Three Phase - TEFC, Rigid Base 60 Hz. Premium Efficient Super-E 1 thru thru 5011L Applications: Energy saving applications where continuous or frequent duty is required. Suitable for use with inverter drives for variable torque and 20:1 constant torque. Premium efficiency, Inverter Ready per standard MG1 Part Features: Class F insulation, 1.15 service factor, low-loss electrical grade lamination steel, Premium efficiency and 3 year warranty EM K 3516M F EM K 3524M E T EM3546T 446 LS 3524M E T EM3546T LS 3524M H T EM3546T L1 3524M I T ECP3580T L1 0516M G T EM3581T 575 L1 0524M E T ECP3581T L1 0524M G T ECP3581T L1 0524M H T EM3582T 643 L1 0528M F T ECP3582T L1 0528M G EM K 3528M E / T EM3583T 524 L1 0524M E / T ECP3583T L1 0524M G / EM K 3524M E / T EM3550T 456 L1 3524M E / EM K 3528M F / T EM3554T 463 LS 3528M F / T EM3554T LS 3528M H / T EM3554T L1 3528M I / T EM3584T 595 L1 0528M E / T ECP3584T L1 0528M G / T ECP3584T L1 0528M H / T EM3667T 766 L1 0634M E / T ECP3667T L1 0632M G T EM3586T 596 L1 0532M E T ECP3586T L1 0532M G EM K 3532M E T EM3555T 500 L1 3532M E EM K 3532M E T EM3558T 480 LS 3532M E T EM3558T LS 3532M H T EM3558T L1 3535M I T EM3587T 624 L1 0532M E T ECP3587T L1 0532M G T ECP3587T L1 0532M H T EM3664T 778 L1 0640M E T ECP3664T L1 0640M G T EM3610T 554 L1 3628M F T EM3660T 689 L1 0628M F T EM3660T L1 0628M I T ECP3660T L1 0628M G T EM3611T 531 LS 3628M E 4.1 NOTE: 60 HZ: E = /460 volts, E1=230/460 usable at 208 volts, F= 230/460, SHADED RATINGS ARE CAST IRON FRAMES G= 460, H= 575, I= 200 volts. See notes on pages 8 and 9, and inside back flap. Type C Dimension Volt Code Amps General Information Single Phase General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Explosion Proof Pump Commercial 25

26 General Information Single Phase General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Explosion Proof Pump Commercial 26 Three Phase - TEFC continued 60 Hz. NOTE: 60 Hz: E1=230/460 volts usable at 208 volts, F= 230/460, G= 460, H= 575, I = 200 volts. See notes on pages 8 and 9, and inside back flap. Premium Efficient Super-E Type C Dimension T EM3611T LS 3628M H T EM3661T 708 L1 0628M E T EM3661T L1 0628M I T EM3661T L1 0628M H T ECP3661T L1 0628M G T ECP3661T L1 0628M H T EM3704T 848 L1 3736M E T EM3764T 970 L1 0736M E T ECP3764T L1 0736M G T ECP3764T L1 0736M H T EM3613T 615 L1 3634M F T EM3663T 848 L1 0634M F T EM3663T L1 0634M I T ECP3663T L1 0634M G T EM3615T 581 LS 3643M E T EM3615T LS 3643M H T EM3665T 709 L1 0643M E T EM3665T L1 0643M I T EM3665T L1 0643M H T ECP3665T L1 0643M G T ECP3665T L1 0643M H T EM3708T 959 L1 3744M E T EM3768T 1126 L1 0744M E T ECP3768T L1 0744M G T ECP3768T L1 0744M H / T EM3709T 922 L1 3733M F / T EM3769T 982 L1 0733M E / T EM3769T L1 0733M I / T ECP3769T L1 0733M G / T EM3710T 838 LS 3744M E / T EM3710T LS 3744M H / T EM3770T 946 L1 0740M E / T EM3770T L1 0740M I / T EM3770T L1 0740M H / T ECP3770T L1 0740M G / T ECP3770T L1 0740M H / T EM2276T 1605 L1 0954M E / T ECP2276T L1 0954M G / T ECP2276T L1 0954M H T EM3711T 935 L1 3744M E T EM3771T 1152 L1 0744M E T EM3771T L1 0744M I T ECP3771T L1 0744M G T EM3714T 947 LS 3750M E T EM3714T LS 3750M H T EM3774T 1062 L1 0750M E T EM3774T L1 0750M I T EM3774T L1 0750M H T ECP3774T L1 0750M G T ECP3774T L1 0750M H T EM2332T 1833 L1 0960M E T ECP2332T L1 0960M G T ECP2332T L1 0960M H 11.5 Volt Code Amps SHADED RATINGS ARE CAST IRON FRAMES

27 Three Phase - TEFC continued 60 Hz. Premium Efficient Super-E NOTE: 60 Hz: E1=230/460 volts usable at 208 volts, F= 230/460, G= 460, H= 575, I = 200, I2= 200 volts, 6 lead, DOL or Part Winding Start. See notes on pages 8 and 9, and inside back flap. Type C Dimension Volt Code Amps T EM2394T 1587 L1 0934M E T EM2394T L1 0934M I T EM2394T L1 0934M H T ECP2394T L1 0934M G T EM2333T 1460 LS 0936M E T EM2333T L1 0936M I T ECP2333T L1 0936M G T ECP2333T L1 0936M H T EM4100T 2445 L1 1054M E T ECP4100T L1 1054M G T ECP4100T L1 1054M H T EM4106T 1742 L1 0944M E T EM4106T L1 0944M I T EM4106T L1 0944M H T ECP4106T L1 0944M G T EM2334T 1770 LS 0952M E T EM2334T L1 0952M I T ECP2334T L1 0952M G T ECP2334T L1 0952M H T EM4102T 3256 L1 1060M E T ECP4102T L1 1060M G T ECP4102T L1 1060M H TS EM4107T 2273 L1 0950M E TS EM4107T L1 0950M I TS EM4107T L1 0950M H TS ECP4107T L1 0950M G T EM4103T 2316 LS 1046M E T EM4103T L1 1046M I T ECP4103T L1 1046M G T ECP4103T L1 1046M H T EM4111T 3684 L1 1080M F T ECP4111T L1 1256M G T ECP4111T L1 1248M H TS EM4108T 2702 L1 0954M E TS EM4108T L1 0954M I TS EM4108T L1 0954M H TS ECP4108T L1 0954M G T EM4104T 2748 LS 1060M E T EM4104T L1 1060M I T ECP4104T L1 1060M G T ECP4104T L1 1060M H T EM4117T 4256 L1 1260M E T ECP4117T L1 1260M G TS EM4109T 3500 L1 1244M E TS EM4109T L1 1244M H TS ECP4109T L1 1244M G T EM4110T 3594 LS 1260M E T EM4110T L1 1260M I T ECP4110T L1 1260M G T ECP4110T L1 1260M H T EM4308T 5304 L1 1468M F T ECP4308T L1 1468M G 50.5 SHADED RATINGS ARE CAST IRON FRAMES General Information Single Phase General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Explosion Proof Pump Commercial 27

28 General Information Single Phase General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Explosion Proof Pump Commercial 28 Three Phase - TEFC continued 60 Hz. Premium Efficient Super-E NOTE: 60 Hz: E1= 230/460 volts usable at 208 volts, F= 230/460,G= 460, H= 575, SHADED RATINGS ARE CAST IRON FRAMES I=200 volts, I2= 200, 6 lead, DOL or Part Winding Start. O=2300/4160 volts. with 449TY and 5007SY have non-standard BA due to drive end bearing cooling fan. Please refer to layout drawing. ECP4408T-4 and ECP44304T-4 do not meet Premium efficiency. A custom motor is available. See notes on pages 8 and 9, and inside back flap. Type C Dimension TS EM4114T 4052 L1 1252M E TS EM4114T L1 1252M H TS ECP4114T L1 1252M G T EM4115T 3928 LS 1266M E T EM4115T L1 1266M I T ECP4115T L1 1266M G T ECP4115T L1 1266M H T EM4312T 6410 L1 1474M E T ECP4312T L1 1474M G TS EM4310T 5693 L1 1458M E TS EM4310T L1 1458M I TS ECP4310T L1 1458M G T EM4314T 5653 LS 1462M E T ECP4314T L1 1462M G T ECP4314T L1 1462M H T EM4403T 7625 D3 1672M F T ECP4403T D3 1672M G TS EM4313T 6624 L1 1472M F TS ECP4313T L1 1472M G T EM4316T 6610 LS 1482M E T ECP4316T L1 1482M G T ECP4316T L1 1482M H T EM4404T 8879 D3 1680M E T ECP4404T D3 1680M G TS ECP4402T D3 1664M G T ECP4400T LS 1684M G T ECP4400T LS 1684M H T ECP4409T D3 1888M G TS ECP4412T D3 1852M G T ECP4410T LS 1876M G T ECP4410T LS 1876M H T ECP4411T D M G TS ECP4413T D3 1856M G T ECP4406T LS 1888M G T ECP4406T LS 1888M H T ECP44156T D M G TS ECP4416T D3 1876M G TS ECP44202T D M O T ECP4407T LS 18136M G T ECP4407T LS 18136M H T ECP44204T D M O T ECP44206T D M G SY ECP50252S D M O TS ECP44252T D M G T ECP4408T LS 18168M G L ECP50254L D M O TY ECP44256T D M G L ECP50256L D M O SY ECP50302S D M O TS ECP44302T D M G TY ECP44304T LS 18160M G L ECP50304L D M O LY ECP50306L D M O 40.0 Volt Code Amps

29 Three Phase - TEFC, continued Premium Efficient Super-E General Information 60 Hz. NOTE: 60 Hz: E = /460 volts, E1=230/460 usable at 208 volts, F= 230/460, G= 460, H= 575, SHADED RATINGS ARE CAST IRON FRAMES O= 2300/4160 volts. See notes on pages 8 and 9, and inside back flap. All motors 449T through 5011L have ball bearing suitable for coupled loads. If load is belted, a roller bearing may be required, contact your local Baldor office. Suffix TR indicates motor has roller bearing suitable for belted loads only. with 449TY, 5007SY, 5009SY and 5011LY have non-standard BA due to drive end bearing cooling fan. Please refer to layout drawing. ECP44306T-4, ECP44354T-4, ECP44404T-4, ECP4408TR-4, ECP44304TR-4 and ECP44306TR-4 do not meet Premium efficiency. A custom motor is available. Custom TEFC motors available through 900 ; Open and WPII motors through Contact your Baldor Sales Representative. Type C Dimension TS ECP44352T D M G TY ECP44354T LS 18168M G LY ECP50354L D M O LY ECP50356L D M G LY ECP50356L D M O SY ECP50402S D M O TS ECP44402T D M G TY ECP44404T LS 18180M G LY ECP50404L D M O LY ECP50406L D M O LY ECP50454L D M O LY ECP50456L D M O SY ECP50502S D M O LY ECP50504L D M O LY ECP50506L D M O 65.0 with Roller Bearings T ECP44156TR D M G T ECP4407TR D M G TY ECP44206TR D M G TY ECP4408TR D M G TY ECP44256TR D M G TY ECP44304TR D M G C-Face less Base C VEM K 3516M F C VEM K 3524M E C VEM K 0524M E TC VEM3581T 587 L1 0524M E TC VEM3581T L1 0524M H C VEM K 3528M E / C VEM K 3524M E / C VEM K 3528M F / TC VEM3584T 610 L1 0528M E / TC VEM3584T L1 0528M H C VEM K 3532M E C VEM K 3532M E TC VEM3587T 641 L1 0532M E TC VEM3587T L1 0532M H TC VEM3661T 746 L1 0628M E TC VEM3661T L1 0628M H TC VEM3665T 776 L1 0640M E TC VEM3665T L1 0640M H / TC VEM3770T 982 L1 0740M E / TC VEM3770T L1 0740M H TC VEM3774T 1102 L1 0750M E Volt Code Amps Single Phase General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Explosion Proof Pump Commercial 29

30 General Information Single Phase General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Explosion Proof Pump Commercial Three Phase - TEFC, C-Face continued 60 Hz. NOTE: 60 Hz: E = /460 volts, E1= 230/460 usable at 208 volts, F= 230/460 volts. H= 575 volts. See notes on pages 8 and 9, and inside back flap. Premium Efficient Super-E Type C Dimension C-Face with Base TC CEM3581T 604 L1 0524M E TC CEM3581T L1 0524M H / TC CEM3583T 592 L1 0524M E / TC CEM3583T L1 0524M H / TC CEM3584T 624 L1 0528M E / TC CEM3584T L1 0528M H TC CEM3586T 611 L1 0532M E TC CEM3586T L1 0532M H TC CEM3587T 655 L1 0532M E TC CEM3587T L1 0532M H TC CEM3660T 743 L1 0628M E TC CEM3660T L1 0628M H TC CEM3661T 761 L1 0628M E TC CEM3661T L1 0628M H TC CEM3663T 913 L1 0634M F TC CEM3663T L1 0634M H TC CEM3665T 794 L1 0640M E TC CEM3665T L1 0640M H / TC CEM3769T 1121 L1 0733M E / TC CEM3769T L1 0733M H / TC CEM3770T 999 L1 0740M E / TC CEM3770T L1 0740M H TC CEM3771T 1210 L1 0744M E TC CEM3771T L1 0744M H TC CEM3774T 1118 L1 0750M E TC CEM3774T L1 0750M H TC CEM2394T 1551 L1 0934M E TC CEM2333T 1627 L1 0936M E TC CEM2333T L1 0936M H TC CEM4106T 1905 L1 0940M E TC CEM2334T 1941 L1 0948M E TC CEM2334T L1 0948M H TSC CEM4107T 2391 L1 0950M E TC CEM4103T 2474 L1 1046M E TC CEM4103T L1 1046M H TC CEM4104T 2980 L1 1060M E TC CEM4110T 3852 L1 1260M E TC CEM4115T 4229 L1 1266M E TC CEM4314T 6703 L1 1462M E TC CEM4316T 7712 L1 1482M E TC CEM4400T 9442 D3 1684M F Volt Code Amps SHADED RATINGS ARE CAST IRON FRAMES 30

31 Three Phase - F2 Mount - TEFC Premium Efficient Super-E General Information General Purpose Premium Efficient Super-E Single Phase 60 Hz T EFM2333T 1452 L1 0936M E T EFM2334T 1759 L1 0948M E T EFM4103T 2301 L1 1046M E T EFM4104T 2733 L1 1060M E NOTE: 60 Hz: E1=230/460 usable at 208 volts. SHADED RATINGS ARE CAST IRON FRAMES See notes on pages 8 and 9, and inside back flap. Three Phase - Explosion Proof - TEFC Type C Dimension Volt Code Amps 60 Hz. NOTE: 60 Hz: E = /460 volts, F= 230/ //60 Hz: SHADED RATINGS ARE CAST IRON FRAMES U= 190/380//230/460 volts, 50//60 Hz See notes on pages 8 and 9, and inside back flap. 1 Class I, Group D only, T2C. 2 Class 1 Group C & D, Class II Group F & G, T4. 7 Class I, Group D, Class II, Group F&G, T4. 8 Class I, Group D, Class II, Group F & G, T3C. Type C Dimension T EM7014T L1 X3524M U T EM7114T-C L1 X0524M E / T EM7034T L1 X3530M U / T EM7134T-C L1 X0528M F T EM7037T L1 X3532M E T EM7137T-C L1 X0532M E T EM7142T-C L1 X0628M U T EM7144T-C L1 X0643M U / T EM7147T-C L1 X0740M U T EM7170T L1 X0750M F T EM7170T-C L1 X0750M U T EM7054T L1 X0942M U T EM7054T-C L1 X0942M U T EM7056T L1 X0952M U T EM7056T-C L1 X0952M U T EM7058T L1 X1050M U T EM7058T-C L1 X1050M U T EM7060T L1 X1056M U T EM7060T-C L1 X1056M U T EM7062T L1 X1260M U T EM7062T-C L1 X1260M U T EM7064T L1 X1266M U T EM7064T-C L1 X1266M U T EM7066T L1 X1462M U T EM7066T-C L1 X1462M U 69.0 Volt Code Amps C-Face Industrial Severe Duty Washdown Duty Explosion Proof Pump Commercial NOTE: These motors resist condensation buildup better than standard explosion proof designs. They are recommended for applications such as fuel transfer terminals and fuel truck loading facilities where motors may run intermittently, applications where explosion-proof motors are installed outdoors exposed to the environment, and may not be operated for extended periods of time. These explosion-proof motors are not suitable for use with adjustable speed drives inverter duty explosion-proof motors must be used. See page

32 General Information Three Phase - ODP Premium Efficient Super-E 1 thru thru 445T Single Phase General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Explosion Proof Pump Commercial 60 Hz. Applications: Energy saving applications where continuous or frequent duty is required. The motors are suitable for use with inverter drives for variable torque and 23:1 constant torque. Inverter Ready per standard MG1 Part Features: Class F insulation, 1.15 service factor, low-loss electrical grade lamination steel, ISR magnet wire, Premium efficiency, and 3 year warranty. NOTE: 60 Hz: E = /460 volts, E1= 230/460 usable at 208 volts, F= 230/460, H= 575, I= 200, I2= 200 volts, DOL or Part Winding Start. See notes on pages 8 and 9, and inside back flap. Type C Dimension EM K 3516M E T EM3116T 389 L1 3520M E T EM3116T L1 3520M I T EM3116T L1 3520M H T EM3156T 457 L1 3528M F / T EM3120T 384 L1 3520M E / T EM3154T 408 L1 3526M E / T EM3154T L1 3526M I / T EM3154T L1 3526M H / T EM3207T 535 L1 3632M E T EM3155T 450 L1 3524M E T EM3157T 436 L1 3532M E T EM3157T L1 3532M I T EM3157T L1 3532M H T EM3215T 547 L1 3640M E T EM3158T 457 L1 3535M E T EM3211T 471 L1 3628M E T EM3211T L1 3628M I T EM3211T L1 3628M H T EM3305T 696 L1 3735M E T EM3212T 499 L1 3634M F T EM3218T 516 L1 3632M E T EM3218T L1 3632M I T EM3218T L1 3632M H T EM3309T 912 L1 3740M E / T EM3219T 793 L1 3640M F / T EM3311T 759 L1 3732M E / T EM3311T L1 3732M I / T EM3311T L1 3732M H / T EM2506T 1095 L1 3956M E T EM3312T 906 L1 3736M E T EM3313T 919 L1 3744M E T EM3313T L1 3746M I T EM3313T L1 3746M H T EM2511T 1424 L1 3954M E T EM3314T 1288 L1 3744M E T EM2513T 1303 L1 3938M E T EM2513T L1 3938M I T EM2513T L1 3938M H T EM2524T 1922 L1 4050M F 19.5 Volt Code Amps 32

33 Three Phase - ODP continued Premium Efficient Super-E General Information 60 Hz. NOTE: 60 Hz: E1=230/460 usable at 208 volts, F= 230/460, G2= 460, 6 lead, SHADED RATINGS ARE CAST IRON FRAMES DOL or Wye Start, Delta Run, H= 575 volts, I2= 200 volts, 6 lead DOL or Part Winding Start. See notes on pages 8 and 9, and inside back flap. Custom TEFC motors available through 900 ; Open and WPII motors through Contact your Baldor Sales Representative. Type C Dimension T EM2514T 1513 L1 3932M E T EM2514T L1 3932M I T EM2515T 1636 L1 3944M E T EM2515T L1 3944M I T EM2515T L1 3944M H T EM2528T 2340 L1 4056M E T EM2516T 1817 L1 3940M E T EM2516T L1 3940M I T EM2531T 1994 L1 4046M E T EM2531T L1 4046M I T EM2531T L1 4046M H T EM2532T 2826 L1 4252M E TS EM2534T 2144 L1 4040M F T EM2535T 2181 L1 4052M E T EM2535T L1 4052M I T EM2535T L1 4052M H T EM2536T 2948 L1 4268M E TS EM2538T 2763 L1 4054M F TS EM2538T L1 4054M I T EM2539T 2846 L1 4250M E T EM2539T L1 4250M I T EM2539T L1 4250M H T EM2540T 4201 L1 1458M E TS EM2542T 3010 L1 4058M F T EM2543T 3141 L1 4256M E T EM2543T L1 4256M I T EM2543T L1 4256M H T EM2544T 5085 L1 1466M E TS EM2546T 3808 L1 4252M F T EM2547T 3954 L1 4278M E T EM2547T L1 4278M I T EM2547T L1 4278M H T EM2548T D3 1666M G TS EM2549T 4996 L1 4254M F T EM2551T 4854 L1 4462M F T EM2551T L1 1462M I T EM2552T D3 1672M G TS EM2550T 5341 L1 4264M F T EM2555T D3 4476M G T EM2555T D3 4476M I T EM2583T D3 1860M G Volt Code Amps Single Phase General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Explosion Proof Pump Commercial 33

34 General Information Single Phase General Purpose Premium Efficient Super-E Three Phase - ODP continued 60 Hz. NOTE: 60 Hz: G2= 460, 6 lead, DOL or Wye Start, Delta Run. See notes on pages 8 and 9, and inside back flap. Three Phase - F2 Mount, ODP Premium Efficient Super-E Type C Dimension TS EM2554T D3 4464M G T EM2559T D3 4488M G T EM2557T D3 1884M G TS EM2556T D3 4472M G T EM2558T D3 1868M G T EM2560T D3 1896M G TS EM2562T D3 1860M G T EM2563T D3 1880M G T EM2564T D M G T EM2566T D3 1892M G T EM2569T D M G Volt Code Amps SHADED RATINGS ARE CAST IRON FRAMES C-Face Industrial Severe Duty Washdown Duty Explosion Proof Pump Commercial 60 Hz. NOTE: 60 Hz: E = /460 volts, E1= 230/460 usable at 208 volts, I= 200 volts. See notes on pages 8 and 9, and inside back flap. Type C Dimension T EFM3116T 389 L1 3520M E / T EFM3154T 408 L1 3526M E T EFM3157T 436 L1 3532M E T EFM3157T L1 3532M I T EFM3211T 471 L1 3628M E T EFM3211T L1 3628M I T EFM3218T 516 L1 3632M E T EFM3218T L1 3632M I / T EFM3311T 759 L1 3732M E / T EFM3311T L1 3732M I T EFM3313T 919 L1 3744M E T EFM3313T L1 3746M I T EFM2513T 1303 L1 3938M E T EFM2513T L1 3938M I T EFM2515T 1636 L1 3944M E T EFM2531T 1994 L1 4046M E T EFM2535T 2181 L1 4052M E T EFM2539T 2846 L1 4250M E T EFM2543T 3141 L1 4256M E T EFM2547T 3954 L1 4278M E Volt Code Amps 34

35 Three Phase - Washdown Duty - TENV and TEFC 60 Hz. Premium Efficient Super-E 1 thru TC thru 256TC Applications: Food processing and other applications that regularly expose the motor to high pressure wash down. Features: 300 series stainless steel hardware, moisture sealant on bolt heads, between frame and endplates. Neoprene gaskets. Double sealed bearings. Forsheda running contact v-ring slinger. Stainless steel shaft. Electrostatically applied epoxy finish. Class F insulation. Tropicalized. ISR magnet wire, Premium efficiency and 3 year warranty. Three Phase, Rigid Base T EWDM3546T 562 L1 3526M E / T EWDM3554T 616 L1 3532M E T EWDM3558T 811 L1 3532M E T EWDM3611T 1013 L1 3628M E T EWDM3615T 1154 L1 3643M E / T EWDM3710T 1445 L1 3744M E T EWDM3714T 1728 L1 3750M E Three Phase, C-Face with Base C CEWDM K 3516M F C CEWDM K 3532M F TC CEWDM3546T 647 L1 3526M E C CEWDM K 3528M E / C CEWDM K 3524M E / TC CEWDM3554T 676 L1 3532M E HCY CEWDM K 3532M E TC CEWDM3555T 800 L1 3532M E TC CEWDM3558T 834 L1 3532M E TC CEWDM3559T 984 L1 3540M F TC CEWDM3611T 1096 L1 3628M E TC CEWDM3613T 1373 L1 3634M E TC CEWDM3615T 1241 L1 3643M E / TC CEWDM3709T 1704 L1 3738M E / TC CEWDM3710T 1571 L1 3744M E TC CEWDM3711T 2022 L1 3744M E TC CEWDM3714T 1787 L1 3750M F TC CEWDM3713T 2490 L1 3752M F TC CEWDM23994T 3311 L1 3752M F TC CEWDM23933T 3259 L1 3942M F TC CEWDM41906T 3802 L1 3940M F TC CEWDM23934T 3781 L1 3952M F 24.0 NOTE: 60 Hz: E = /460 volts, E1=230/460 usable at 208 volts, F = 230/460 volts. See notes on pages 8 and 9, and inside back flap. Type C Dimension Volt Code Amps General Information Single Phase General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Explosion Proof Commercial Pump 35

36 General Information Single Phase General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Explosion Proof Pump Commercial 36 Three Phase - SSE Super-E - All Stainless Steel - TEFC and TENV 60 Hz. NOTE: 60 Hz: E = /460 volts, E1=230/460 usable at 208 volts, F = 230/460 volts. See notes on pages 8 and 9, and inside back flap. Red catalog number = New item Premium Efficient Super-E 1/2 thru 10 56C thru 215TC Applications: Food processing, packaging, outdoor and highly corrosive environments. Features: All external surfaces 300 series stainless steel: motor frame, endplates, conduit box, shaft and base. Moisture resistant 200 C ISR magnet wire. Hydrophobic aspiration system eliminates condensation from inside the motor. Endplate rabbets have O-ring seals to band. Conduit box is welded to the motor frame. Patented bearing seal to protect motor bearings, inside and out. Epoxy encapsulation prevents any moisture from reaching the windings as well as potting the passage between the band and the conduit box. Nameplate information is laser etched on the band. numbers also etched on both sides. Especially effective in highly corrosive environments where paint or other finishes do not hold up. Premium efficiency and 3-year warranty. Type C Dimension C-Face with Base 1/ C CSSEWDM K 3516M E 0.8 1/ C CSSEWDM K 3520M E 0.8 3/ C CSSEWDM K 3520M E 1.0 3/ C CSSEWDM K 3524M E C CSSEWDM K 3524M E C CSSEWDM K 3526M E TC CSSEWDM3546T 931 L1 3526M E / C CSSEWDM K 3532M E / TC CSSEWDM3550T 934 L1 3532M E / C CSSEWDM K 3532M E / TC CSSEWDM3554T 939 L1 3532M E TC CSSEWDM3555T 1121 L1 3535M E TC CSSEWDM3558T 1138 L1 3532M E TC CSSEWDM3559T 1365 L1 3535M E TC CSSEWDM3611T 1374 L1 3630M F TC CSSEWDM3613T 1492 L1 3634M F TC CSSEWDM3615T 1504 L1 3646M E / TC CSSEWDM3709T 1739 L1 3735M F / TC CSSEWDM3710T 1776 L1 3744M E TC CSSEWDM3711T 1975 L1 3744M E TC CSSEWDM3714T 2095 L1 3750M E C-Face less Base 1/ C VSSEWDM K 3516M E 0.8 1/ C VSSEWDM K 3520M E 0.8 3/ C VSSEWDM K 3520M E 1.0 3/ C VSSEWDM K 3524M E C VSSEWDM K 3524M E C VSSEWDM K 3526M E TC VSSEWDM3546T 915 L1 3526M E / C VSSEWDM K 3532M E / TC VSSEWDM3550T 918 L1 3532M E / C VSSEWDM K 3532M E / TC VSSEWDM3554T 923 L1 3532M E TC VSSEWDM3555T 1105 L1 3535M E TC VSSEWDM3558T 1122 L1 3532M E 2.7 Volt Code Amps

37 Three Phase - Close-Coupled Pump - TEFC and ODP 60 Hz. Premium Efficient Super-E 1 thru JM thru 324JM Applications: Energy saving close coupled pump applications where continuous or frequent duty is required. The motors are suitable for use with inverter drives for variable torque and 20:1 constant torque. Features: Class F insulation, 1.15-service factor, low-loss electrical grade lamination steel, ISR magnet wire. Inverter Ready per standard MG1 Part Premium efficiency and 3 year warranty. Totally Enclosed Fan Cooled (TEFC), C-Face with Base JM EJMM3546T 520 L1 3524M E / JM EJMM3550T 516 L1 3524M E / JM EJMM3554T 553 L1 3528M F JM EJMM3555T 554 L1 3532M E JM EJMM3558T 565 L1 3532M E JM EJMM3559T 595 L1 3540M E JM EJMM3610T 596 L1 3540M E JM EJMM3611T 656 L1 3628M E JM EJMM3613T 707 L1 3634M E JM EJMM3615T 658 L1 3643M E / JM EJMM3709T 927 L1 3733M E / JM EJMM3710T 1002 L1 3744M E JM EJMM3711T 1065 L1 3744M E JM EJMM3714T 1179 L1 3750M E JM EJMM2394T 1947 L1 0934M E JM EJMM2333T 1930 L1 0936M E JM EJMM4106T 2144 L1 0940M E JM EJMM2334T 2178 L1 0952M E JM EJMM4107T 2492 L1 1038M E JM EJMM4103T 2581 L1 1046M E JM EJMM4108T 3428 L1 1042M E JM EJMM4104T 3059 L1 1060M E JM EJMM4109T 3617 L1 1240M E JM EJMM4110T 3977 L1 1260M E JM EJMM4114T 4698 L1 1252M E JM EJMM4115T 4781 L1 1266M E Totally Enclosed Fan Cooled (TEFC), C-Face less base JM VEJMM3546T 434 L1 3524M E / JM VEJMM3554T 458 L1 3528M E JM VEJMM3558T 549 L1 3535M E JM VEJMM3611T 626 L1 3628M E JM VEJMM3615T 722 L1 3640M E / JM VEJMM3710T 1059 L1 3735M F JM VEJMM3714T 1226 L1 3750M E Open Drip Proof (ODP), C-Face with Base JM EJMM3116T 444 L1 3520M E / JM EJMM3154T 480 L1 3526M E JM EJMM3155T 531 L1 3524M E JM EJMM3157T 526 L1 3532M E JM EJMM3158T 597 L1 3535M E JM EJMM3211T 582 L1 3628M E 4.1 NOTE: 60 Hz: E = /460 volts, E1= 230/460 usable at 208 volts, F = 230/460 volt, H= 575. SHADED RATINGS ARE CAST IRON FRAMES See notes on pages 8 and 9, and inside back flap. Type C Dimension Volt Code Amps General Information Single Phase General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Explosion Proof Pump Commercial 37

38 General Information Single Phase General Purpose Premium Efficient Super-E C-Face Industrial Three Phase - Close-Coupled Pump ODP continued 60 Hz. NOTE: 60 Hz: E1= 230/460 usable at 208 volts, F = 230/460 volt, H= 575. See notes on pages 8 and 9, and inside back flap. Premium Efficient Super-E Type C Dimension Open Drip Proof (ODP), C-Face with Base JM EJMM3212T 712 L1 3634M E JM EJMM3218T 658 L1 3632M E / JM EJMM3219T 842 L1 3646M E / JM EJMM3311T 988 L1 3732M E JM EJMM3312T 1085 L1 3736M E JM EJMM3313T 1069 L1 3744M F JM EJMM3314T 1351 L1 3744M E JM EJMM2513T 1582 L1 3938M E JM EJMM2514T 1669 L1 3932M E JM EJMM2515T 1895 L1 3944M E JM EJMM2516T 2085 L1 3940M E JM EJMM2534T 2651 L1 4040M F JM EJMM2538T 2957 L1 4054M F JM EJMM2542T 3599 L1 4058M F 55.0 Open Drip Proof (ODP), C-Face less Base JM VEJMM3116T 444 L1 3524M E / JM VEJMM3154T 458 L1 3530M E JM VEJMM3157T 461 L1 3532M E JM VEJMM3211T 590 L1 3628M E JM VEJMM3218T 662 L1 3632M E / JM VEJMM3311T 996 L1 3744M E JM VEJMM3313T 1078 L1 3750M E 12.5 Volt Code Amps Severe Duty Washdown Duty Explosion Proof Pump Commercial 38

39 Single Phase - TEFC, Rigid Base Premium Efficient Super-E 1/4 thru 5 48 thru 184T Applications: Energy saving applications where continuous or frequent duty is required. Features: Low-loss electrical grade lamination steel, heavy gauge steel frames, three year warranty. General Information Single Phase 60 Hz. 1/ EL K 3414LC B 1.3 1/ EL K 3418LC B 1.6 1/ EL K 3424LC B 2.3 3/ EL K 3528LC B H EL K 3532LC B / H EL K 3540LC B / T EL3514T 548 L1 3540LC B T EL3605T 749 L1 3623LC B T EL3609T 874 L1 3640LC C T EL3612T 1044 L1 3646LC C 19.1 NOTE: 60 Hz: B= 115/230, C= 230. See notes on pages 8 and 9, and inside back flap. Type C Dimension Volt Code Amps General Purpose Premium Efficient Super-E C-Face Industrial Single Phase - ODP, Rigid Base 1/4 thru 5 48 thru 184T Applications: Energy saving applications where continuous or frequent duty is required. Features: Low-loss electrical grade lamination steel, heavy gauge steel frames, year warranty. Severe Duty Washdown Duty 60 Hz. 1/ EL K 3414LC B 1.3 1/ EL K 3418LC B 1.6 1/ EL K 3424LC B 2.3 3/ EL K 3524LC B EL K 3528LC B / H EL K 3535LC B / T EL1319T 565 L1 3535LC B T EL1405T 639 L1 3623LC B T EL1408T 667 L1 3634LC C T EL1410T 763 L1 3646LC C 19.1 NOTE: 60 Hz: B= 115/230, C= 230. See notes on pages 8 and 9, and inside back flap. Type C Dimension Volt Code Amps Explosion Proof Pump Commercial 39

40 General Information Single Phase Single Phase - C-Face - TEFC C-Face Industrial 1/6 thru 10 56C thru 215TC Applications: Pumps, fans, conveyors, machine tools, gear reducers and other applications requiring a C-face motor. Features: Pressure cast aluminum end plates with ribbed design for rigidity. Ball bearings with a locked drive end bearing, heavy gauge steel frame, and gasketed conduit box and capacitor cover. General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Explosion Proof Pump Commercial Hz. NOTE: 60 Hz: B= 115/230, B1= 115/230 volts usable at 208 volts, C= 230. See notes on pages 8 and 9, and inside back flap. Type C Dimension C-Face less Base, No Drip Cover 1/ C KL K 3408L B / C KL K 3418L B / C KL K 3411L B / C KL K 3413L B / C VL K 3414L B / C VL K 3413L B / C VL K 3421L B / C VL K 3528L B / C VL K 3424L B / C VL3506A 283 K 3516L B 4.9 3/ C VL K 3428LC B / C VL K 3528LC B C VL K 3520L B C VL3509A 347 K 3524L B C VL K 3524L B TC VL3510T 398 L1 3524L B / C VL K 3524L B / TC VL3513T 463 L1 3524L B / C VL K 3532LC B / TC VL3514T 449 L1 3532LC B C VL K 3535L B TC VL3515T 540 L1 3535L B TC VL3605T 808 L1 3628L B C VL L1 3628L B TC VL3606T 901 L1 3634L B TC VL3609T 953 L1 3634LC B C-Face with Base, No Drip Cover 1/ C CL K 3414L B / C CL K 3413L B / C CL K 3421L B / C CL K 3424L B / C CL K 3428LC B C CL K 3520L B C CL K 3524L B / C CL K 3528L B / C CL K 3532LC B C CL K 3535L B TC CL3515T 543 L1 3535L B TC CL3516TM 685 L1 3535LC C TC CL3619TM 955 L1 3634LC C TC CL3608TM 984 L1 3640LC C TC CL3612TM 1000 L1 3646LC C TC CL3711T 1345 L1 3744LC C TC CL3712T 1362 L1 3756LC C 40.0 Volt Code Amps

41 Single Phase - C-Face - ODP C-Face Industrial 1/6 thru 5 56C thru 184TC Applications: Pumps, fans, conveyors, machine tools, gear reducers and other applications requiring a C-face motor. Features: Pressure cast aluminum end plates with ribbed design for rigidity. Ball bearings with a locked drive end bearing, heavy gauge steel frame, and gasketed conduit box and capacitor cover General Information Single Phase 60 Hz. Type NOTE: 60 Hz: B= 115/230, B1= 115/230 volts usable at 208 volts, D1= 230 volts usable at 208 volts. See notes on pages 8 and 9, and inside back flap. C Dimension C-Face less Base with Drip Cover 1/ C KL K 3408L B / C KL K 3411L B / C KL K 3413L B / C KL1205A 192 K 3413L B / C VL K 3414L B / C VL K 3413L B / C VL1303A 206 K 3420L B 3.7 1/ C VL K 3418L B / C VL K 3524L B / C VL K 3420L B / C VL1306A 270 K 3424L B 5.5 3/ C VL K 3428L B / C VL1307A 350 K 3520L B 5.4 3/ C VL K 3528LC B C VL K 3428L B C VL1309A 292 K 3428L B C VL K 3520L B C VL K 3528L B C VL1318A 400 K 3528L B / C VL K 3428LC B / C VL1313A 384 K 3432LC B / C VL K 3528L B / TC VL1321T 481 L1 3535L B C VL K 3528L B C VL1317A 495 K 3528L B TC VL1322T 478 L1 3532LC B C VL1323A 503 K 3535LC D TC VL1406T 584 L1 3532LC B TC VL1408T 647 L1 3634LC B C-Face with Base, No Drip Cover 1/ C CL K 3414L B / C CL K 3413L B / C CL K 3418L B / C CL K 3428L B C CL K 3520L B TC CL1408TM 624 L1 3634LC B TC CL1410TM 787 L1 3640LC D TC CL1430TM 769 L1 3634LC D Volt Code Amps General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Explosion Proof Pump Commercial 41

42 General Information Single Phase Three Phase - C-Face - TEFC and TENV, Less Base C-Face Industrial 1/4 thru 30 56C thru 286TC Applications: Pumps, fans, conveyors, machine tools, gear reducers and other applications requiring a C-face motor. Features: Ball bearings with a locked drive end bearing and heavy gauge steel or cast iron frame. VEM Super-E motors have Premium efficiency and 3 year warranty. General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Explosion Proof Pump Commercial Hz. NOTE: 60 Hz: E = /460, E1=230/460 usable at 208 volts, F=230/460 volts. See notes on pages 8 and 9, and inside back flap. Type C Dimension 1/ C KM K 3410M E / C KNM K 3410M E 0.7 1/ C VM K 3411M E / C KM K 3410M E / C VM LS 3413M E / C KNM K 3416M E 0.7 1/ C VM K 3414M E / C VM K 3410M E / C VM LS 3416M E / C VNM K 3416M E 1.0 1/ C VM K 3418M E / C VM K 3413M E / C VM LS 3420M E 1.5 3/ C VNM K 3428M E / C VM K 3428M E 1.5 3/ TC VM3543T 412 L1 3428M E C VM K 3416M E C VEM K 3516M F C VM LS 3426M E C VEM K 3524M E C VEM K 0524M E TC VEM3581T 587 L1 0524M E TC VM3546T 324 LS 3426M E C VM L1 3516M E C VM K 3524M E C VEM K 3528M E TC VM3556T 405 L1 3524M E / C VM K 3424M E / C VEM K 3524M E / TC VM3550T 335 L1 3424M E / C VM LS 3520M E / C VEM K 3528M F / TC VM3554T 329 LS 3520M E / TC VEM3584T 610 L1 0528M E / C VM L1 3520M E / C VM K 3528M F / TC VM3557T 461 L1 3528M F / C VM L1 3528M F C VM K 3428M E C VEM K 3532M E TC VM3555T 385 L1 3428M E C VM LS 3528M E C VEM K 3532M E 2.7 Volt Code Amps SHADED RATINGS ARE CAST IRON FRAMES

43 Three Phase - C-Face - TEFC, Less Base continued C-Face Industrial General Information 60 Hz. NOTE: 60 Hz: E = /460 volts, E1=230/460 volts usable at 208 volts. See notes on pages 8 and 9, and inside back flap. Type C Dimension TC VEM3587T 641 L1 0532M E TC VM3558T 341 LS 3528M E C VM L1 3528M E C VM L1 3628M E TC VM3614T 530 L1 3628M E C VM K 3528M E TC VM3559T 438 L1 3528M E TC VM3610T 485 L1 3528M E C VM L1 3528M E C VM K 3535M E TC VEM3661T 746 L1 0628M E TC VM3611T 426 LS 3535M E C VM LS 3535M E C VM L1 3623M E TC VM3704T 668 L1 3726M E C VM L1 3726M E TC VM3613T 543 L1 3628M E C VM L1 3628M E TC VEM3665T 776 L1 0640M E TC VM3615T 489 LS 3634M E C VM LS 3634M E C VM L1 3634M E TC VM3708T 906 L1 3740M E / TC VM3616T 719 L1 3640M E / TC VM3709T 812 L1 3723M E / TC VEM3770T 982 L1 0740M E / TC VM3710T 627 LS 3729M E TC VM3711T 862 L1 3735M E TC VEM3774T 1102 L1 0750M E TC VM3714T 753 LS 3740M E TC VM3713T 1213 L1 3744M E TC VM2333T 1283 LS 0744M E TC VM2394T 1232 L1 0744M E TC VM4106T 1543 L1 0750M E TC VM2334T 1588 LS 0938M E TSC VM4107T 1825 L1 0942M E TC VM4103T 1962 LS 1034M E TSC VM4108T 2113 L1 0954M E TC VM4104T 2287 LS 1040M E Volt Code Amps SHADED RATINGS ARE CAST IRON FRAMES Single Phase General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Explosion Proof Commercial Pump 43

44 General Information Single Phase Three Phase - C-Face - ODP, Less Base C-Face Industrial 1/4 thru 30 56C thru 284TC Applications: Pumps, fans, conveyors, machine tools, gear reducers and other applications requiring a C-face motor. Features: Pressure cast aluminum end plates with ribbed design for rigidity. Ball bearings with a locked drive end bearing and heavy gauge steel frames. General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Explosion Proof Pump Commercial Hz TSC VM2534T 1746 L1 3938M E NOTE: 60 Hz: E = /460 volts, E1= 230/460 usable at 208 volts, F = 230/460 volts. See notes on pages 8 and 9, and inside back flap. Type C Dimension 1/ C KM K 3410M E / C KM K 3410M E / C VM LS 3413M E / C VM K 3410M E / C VM LS 3416M E / C VM K 3418M E / C VM K 3413M E / C VM LS 3420M E 1.5 3/ C VM K 3428M E 1.5 3/ TC VM3153T 385 L1 3428M E C VM K 3416M E C VM LS 3424M E TC VM3116T 286 LS 3424M E TC VM3156T 413 L1 3524M E / C VM K 3424M E / TC VM3120T 323 L1 3424M E / C VM LS 3520M E / TC VM3154T 313 LS 3520M E / TC VM3159T 446 L1 3528M F C VM K 3428M E TC VM3155T 379 L1 3428M E C VM LS 3524M E TC VM3157T 346 LS 3524M E TC VM3215T 465 L1 3623M F C VM K 3524M E TC VM3158T 398 L1 3524M E TC VM3161T 419 L1 3535M E TC VM3211T 387 L1 3535M E C VM L1 3535M E TC VM3305T 592 L1 3726M E TC VM3212T 412 L1 3628M E C VM L1 3625M E TC VM3218T 425 L1 3625M E TC VM3309T 757 L1 3735M E / TC VM3219T 547 L1 3634M E / TC VM3311T 599 L1 3726M E TC VM3312T 738 L1 3725M E TC VM3313T 755 L1 3729M E TC VM3314T 1080 L1 3735M E TC VM2513T 1102 L1 3926M F TC VM2514T 1313 L1 3744M F TC VM2515T 1349 L1 3930M E TC VM2516T 1523 LS 3928M E TC VM2531T 1640 L1 3942M E Volt Code Amps

45 Three Phase - C-Face - TEFC, with Base C-Face Industrial 1/3 thru C thru 405TC Applications: Pumps, fans, conveyors, machine tools, gear reducers and other applications requiring a C-face motor. Features: Ball bearings with a locked drive end bearing, dynamically balanced rotor and heavy gauge steel or cast iron frame. CEM Super-E motors have Premium efficiency and 3 year warranty. General Information Single Phase 60 Hz. NOTE: 60 Hz: E = /460 volts, E1= 230/460 usable at 208 volts, F = 230/460 volts. See notes on pages 8 and 9, and inside back flap. Type C Dimension 1/ C CM LS 3413M E / C CM K 3410M E / C CM LS 3416M E / C CM K 3418M E / C CM K 3413M E / C CM LS 3420M E 1.5 3/ C CM K 3428M E C CM K 3416M E C CM K 3426M E TC CEM3581T 604 L1 0524M E TC CM3546T 361 LS 3518M E C CM K 3524M E TC CM3556T 458 L1 3526M E / C CM K 3424M E / TC CEM3583T 592 L1 0524M E / TC CM3550T 396 L1 3520M E / C CM K 3520M E / TC CEM3584T 624 L1 0528M E / TC CM3554T 367 LS 3524M E / C CM K 3528M F / TC CM3607T 502 L1 3628M E C CM K 3428M E TC CM3555T 435 L1 3526M E TC CEM3586T 611 L1 0532M E TC CEM3587T 655 L1 0532M E C CM K 3528M E TC CM3558T 385 LS 3528M E TC CM3614T 578 L1 3632M E C CM K 3528M E TC CM3559T 494 L1 3535M E TC CEM3660T 743 L1 0628M E TC CM3610T 547 L1 3535M E TC CM3660T 680 L1 0623M E TC CEM3661T 761 L1 0628M E TC CM3611T 489 LS 3546M E TC CM3661T 670 L1 0628M E TC CM3704T 722 L1 3729M E TC CEM3663T 913 L1 0634M F TC CM3613T 620 L1 3630M E TC CM3663T 855 L1 0630M E TC CEM3665T 794 L1 0640M E TC CM3615T 555 LS 3634M E TC CM3665T 705 L1 0638M E TC CM3708T 929 L1 3735M E 8.1 Volt Code Amps SHADED RATINGS ARE CAST IRON FRAMES General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Explosion Proof Pump Commercial 45

46 General Information Three Phase - C-Face - TEFC, with Base continued C-Face Industrial Single Phase General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Explosion Proof Pump Commercial 60 Hz. NOTE: 60 Hz: E = /460 volts, E1=230/460 usable at 208 volts, F= 230/460 volts, H=575 volts SHADED RATINGS ARE CAST IRON FRAMES See notes on pages 8 and 9, and inside back flap. Custom TEFC motors available through 900 ; Open and WPII motors through Contact your Baldor Sales Representative. Type C Dimension 7 1/ TC CM3616T 797 L1 3640M E / TC CEM3769T 1121 L1 0733M E / TC CM3709T 908 L1 3640M E / TC CM3769T 1067 L1 0728M E / TC CEM3770T 999 L1 0740M E / TC CM3710T 709 LS 3735M E / TC CM3770T 923 L1 0735M E TC CEM3771T 1210 L1 0744M E TC CM3711T 942 L1 3732M E TC CM3771T 1137 L1 0732M F TC CEM3774T 1118 L1 0750M E TC CM3714T 849 LS 3740M E TC CM3774T 992 L1 0740M E TC CM3713T 1237 L1 3750M E TC CEM2394T 1551 L1 0934M E TC CM3773T 1426 L1 0750M E TC CEM2333T 1627 L1 0936M E TC CM2333T 1460 LS 0756M F TC CEM4106T 1905 L1 0940M E TC CM4106T 1675 L1 0750M E TC CEM2334T 1941 L1 0948M E TC CM2334T 1762 L1 0938M E TSC CEM4107T 2391 L1 0950M E TSC CM4107T 2009 L1 0942M E TC CEM4103T 2474 L1 1046M E TC CM4103T 2178 L1 0956M E TSC CM4108T 2298 L1 0954M E TC CEM4104T 2980 L1 1060M E TC CM4104T 2539 L1 0964M E TC CM4104T L1 1044M H TSC CM4109T 3253 L1 1050M E TC CEM4110T 3852 L1 1260M E TC CM4110T 3328 L1 1068M E TSC CM4114T 3289 L1 1064M E TC CEM4115T 4229 L1 1266M E TC CM4115T 3572 L1 1080M E TSC CM4310T 4928 L1 1450M E TC CEM4314T 6703 L1 1462M E TC CM4314T 5143 L1 1454M E TSC CM4313T 5915 L1 1456M E TC CEM4316T 7712 L1 1482M E TC CM4316T 6155 L1 1462M E TC CEM4400T 9442 D3 1684M F TC CM4400T 7807 D3 1480M F Volt Code Amps 46

47 Three Phase - C-Face - ODP, with Base C-Face Industrial 1/3 thru C thru 405TC Applications: Pumps, fans, conveyors, machine tools, gear reducers. General Information Features: Pressure cast aluminum end plates with ribbed design for rigidity, ball bearings, locked drive end bearing, heavy gauge steel frame. Single Phase 60 Hz. NOTE: 60 Hz: E = /460 volts, E1=230/460 usable at 208 volts. See notes on pages 8 and 9, and inside back flap. Type C Dimension 1/ C CM K 3413M E / C CM K 3410M E / C CM K 3416M E / C CM K 3420M E TC CM3116T 333 L1 3518M E / TC CM3154T 351 L1 3524M E C CM K 3428M E TC CM3157T 374 L1 3526M E TC CM3158T 385 L1 3528M E TC CM3211T 426 L1 3540M E TC CM3212T 415 L1 3535M E TC CM3218T 476 L1 3628M E / TC CM3219T 678 L1 3630M E / TC CM3311T 675 L1 3646M E TC CM3312T 830 L1 3725M E TC CM3313T 821 L1 3738M E TC CM3314T 1187 L1 3735M E TC CM2513T 1202 L1 3752M E TC CM2514T 1451 L1 3930M E TC CM2515T 1468 L1 3936M E TC CM2516T 1769 L1 3934M E TC CM2531T 1789 L1 3942M E TC CM2535T 2043 L1 3952M E TC CM2539T 2592 L1 4052M E TC CM2543T 3004 L1 4060M E TC CM2547T 3648 L1 4252M E TC CM2551T 4432 L1 4272M E TC CM2555T 5629 D3 4464M E Volt Code Amps General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Explosion Proof Commercial Pump 47

48 General Information Single Phase Single and Three Phase - Foot or C-Face Mounting - TENV, Removable Base 1/12 thru 1/4 42C C-Face Industrial Applications: General purpose fractional horsepower applications including pumps, compressors, machine tools, and air handling. Features: C-face with removable base, rugged cast aluminum housing having a dry powder epoxy coating, and ball bearings with the drive end bearing locked. General Purpose Premium Efficient Super-E C-Face Industrial 60 Hz. NOTE: 60 Hz: E= /460, L = 115, U=190/380//230/460 volts, 50//60 Hz. See notes on pages 8 and 9, and inside back flap. Type C Dimension Single Phase Permanent Split Capacitor 1/ C CNL DS 2514C L 1.1 1/ C CNL DS 2520C L 1.6 1/ C CNL DS 2524C L 1.9 Three Phase 1/ C CNM DS 2510M E 0.4 1/ C CNM DS 2516M E 0.4 1/ C CNM DS 2520M U 0.5 Volt Code Amps Severe Duty Washdown Duty Explosion Proof Pump Commercial 48

49 Three Phase & 230/460 Volts - Rigid Base 60 Hz. Severe Duty 1 thru T thru 449T Applications: Petro-chemical plants, mines, foundries, pulp and paper plants, waste management facilities, chemical plants, tropical climates and other processing industry applications requiring corrosion protection from severe environmental operating conditions. Features: 1.15 Service Factor, corrosion resistant epoxy finish, regreasable ball or roller bearings, oversized rotatable cast iron conduit box, cast iron frames, Forsheda shaft seal, moisture resistant copper windings, Class F insulation, tropicalization, stainless steel nameplate and corrosion resistant hardware. ECP Super-E motors have Premium efficiency and 3 year warranty T ECP3580T L1 0516M G T CP3580T L1 0513M G T ECP3581T 656 L1 0524M E T ECP3581T L1 0524M G T CP3581T 528 L1 0518M E T CP3581T L1 0518M G T ECP3582T 725 L1 0528M E T ECP3582T L1 0528M G T CP3582T 628 L1 0526M E T CP3582T L1 0526M G / T ECP3583T L1 0524M G / T CP3583T L1 0520M G / T ECP3584T 668 L1 0528M E / T ECP3584T L1 0528M G / T CP3584T 539 L1 0524M E / T CP3584T L1 0524M G / T ECP3667T 848 L1 0634M E / T ECP3667T L1 0632M G / T CP3667T 722 L1 0625M E / T CP3667T L1 0625M G T ECP3586T L1 0532M G T CP3586T L1 0526M G T ECP3587T 698 L1 0532M E T ECP3587T L1 0532M G T CP3587T 553 L1 0528M E T CP3587T L1 0528M G T ECP3664T 859 L1 0640M E T ECP3664T L1 0640M G T CP3664T 670 L1 0632M E T CP3664T L1 0632M G T ECP3660T L1 0628M G T CP3660T L1 0623M G T ECP3661T 884 L1 0628M E T ECP3661T L1 0628M G T CP3661T 778 L1 0628M E T CP3661T L1 0628M G T ECP3764T 1242 L1 0736M E T ECP3764T L1 0736M G T CP3764T 1049 L1 0729M E T CP3764T L1 0729M G 5.1 NOTE: All ratings are 1.15 service factor at 40 C ambient. All ratings meet 50 C ambient at 1.00 service SHADED RATINGS ARE CAST IRON FRAMES factor and weatherproof requirements for IEEE 45 and USCG 259 marine duty (below deck). 60 HZ: E = /460 volts, E1=230/460 usable at 208 volts, G = 460 volts. See notes on pages 8 and 9, and inside back flap. FOR OTHER /460 VOLT REQUIREMENTS, PLEASE SEE DIRTY DUTY MOTORS ON PAGE 61. Type C Dimension Volt Code Amps General Information Single Phase General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Explosion Proof Pump Commercial 49

50 General Information Single Phase General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Explosion Proof Pump Commercial 50 Three Phase & 230/460 Volts - Rigid Base continued 60 Hz. Type NOTE: 60 Hz: E = /460 volts, E1=230/460 usable at 208 volts, F = 230/460 volts, G = 460 volts. See notes on pages 8 and 9, and inside back flap. All ratings meet 50 C ambient at 1.00 service factor and weatherproof requirements for IEEE 45 and USCG 259 marine duty (below deck). All ratings are 1.15 service factor at 40 C ambient. FOR OTHER /460 VOLT REQUIREMENTS, PLEASE SEE DIRTY DUTY MOTORS ON PAGE 61. C Dimension Severe Duty T ECP3663T L1 0634M G T CP3663T L1 0630M G T ECP3665T 899 L1 0643M E T ECP3665T L1 0643M G T CP3665T 803 L1 0638M E T CP3665T L1 0638M G T ECP3768T 1258 L1 0744M E T ECP3768T L1 0744M G T CP3768T 1221 L1 0735M E T CP3768T L1 0735M G / T ECP3769T L1 0733M G / T CP3769T L1 0728M G / T ECP3770T 1133 L1 0740M E / T ECP3770T L1 0740M G / T CP3770T 1072 L1 0735M E / T CP3770T L1 0735M E / T ECP2276T 1801 L1 0954M E / T ECP2276T L1 0954M G / T CP2276T 1326 L1 0760M E / T CP2276T L1 0760M G T ECP3771T L1 0744M G T CP3771T L1 0732M G T ECP3774T 1357 L1 0750M E T ECP3774T L1 0750M G T CP3774T 1162 L1 0740M E T CP3774T L1 0740M G T ECP2332T 2340 L1 0960M E T ECP2332T L1 0960M G T CP2332T 1876 L1 0946M E T CP2332T L1 0946M G T ECP2394T L1 0934M G T CP2394T L1 0750M G T CP3773T L1 0750M G T ECP2333T 1729 L1 0936M E T ECP2333T L1 0936M G T CP2333T 1544 L1 0756M F T CP2333T L1 0756M G T ECP4100T 2682 L1 1054M E T ECP4100T L1 1054M G T CP4100T 2638 L1 1036M E T CP4100T L1 0960M G T ECP4106T L1 0944M G T CP4106T L1 0750M G T ECP2334T 1855 L1 0952M E T ECP2334T L1 0952M G T CP2334T 1720 L1 0938M E T CP2334T L1 0938M G T ECP4102T 3645 L1 1060M E T ECP4102T L1 1060M G T CP4102T 3075 L1 1042M E T CP4102T L1 1042M G 26.0 Volt Code Amps SHADED RATINGS ARE CAST IRON FRAMES

51 Three Phase & 230/460 Volts - Rigid Base continued 60 Hz. NOTE: 60 Hz: E = /460 volts, E1=230/460 usable at 208 volts, G = 460 volts. See notes on pages 8 and 9, and inside back flap. Type C Dimension Severe Duty TS ECP4107T L1 0950M G TS CP4107T L1 0942M G T ECP4103T 2427 L1 1046M E T ECP4103T L1 1046M G T CP4103T 2087 L1 0956M E T CP4103T L1 0956M G T ECP4111T 3809 L1 1256M E T ECP4111T L1 1256M G T CP4111T 3752 L1 1072M E T CP4111T L1 1072M G TS ECP4108T L1 0954M G TS CP4108T L1 0954M G T ECP4104T 2883 L1 1060M E T ECP4104T L1 1060M G T CP4104T L1 0964M G T CP4104T 2504 L1 0964M E T ECP4117T 4911 L1 1260M E T ECP4117T L1 1260M G T CP4117T 3979 L1 1258M E T CP4117T L1 1248M G TS ECP4109T L1 1244M G TS CP4109T L1 1050M G T ECP4110T 3771 L1 1260M E T ECP4110T L1 1260M G T CP4110T 3333 L1 1068M E T CP4110T L1 1248M G T ECP4308T 6122 L1 1464M E T ECP4308T L1 1468M G T CP4308T 5510 L1 1464M E TS ECP4114T L1 1252M G T ECP4115T 4427 L1 1266M E T ECP4115T L1 1266M G T CP4115T 3934 L1 1080M E T CP4115T L1 1080M G T ECP4312T 6520 L1 1474M E T ECP4312T L1 1474M G T CP4312T 5868 L1 1456M E TS ECP4310T L1 1458M G T ECP4314T 5934 L1 1462M E T ECP4314T L1 1462M G T CP4314T 5326 L1 1454M E T CP4314T L1 1454M G T ECP4403T 8729 L1 1662M E T ECP4403T D3 1672M G T CP4403T 8032 D3 1672M E TS ECP4313T L1 1472M G T ECP4316T 6934 L1 1482M E T ECP4316T L1 1482M G T CP4316T 6401 L1 1476M E T CP4316T L1 1462M G T ECP4404T L1 1680M E T ECP4404T D3 1680M G T CP4404T 9563 L1 1678M E Volt Code Amps SHADED RATINGS ARE CAST IRON FRAMES General Information Single Phase General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Explosion Proof Pump Commercial 51

52 General Information Single Phase General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Three Phase & 230/460 Volts - Rigid Base continued 60 Hz. NOTE: 60 Hz: G = 460 volts. See notes on pages 8 and 9, and inside back flap. Suffix TR indicates motor has roller bearing suitable for belted loads only. with 449TY have non-standard BA due to drive end bearing cooling fan. Please refer to layout drawing. ECP4408T-4, ECP44304T-4, ECP44306T-4, ECP44354T-4, ECP44404T-4, ECP4408TR-4, ECP44304TR-4 and ECP44306TR-4 do not meet Premium efficiency. A custom motor is available. Custom TEFC motors available through 900 ; Open and WPII motors through Contact your Baldor Sales Representative. Type C Dimension Severe Duty Volt Code Amps TS ECP4402T D3 1664M G T ECP4400T LS 1684M G T CP4400T D3 1480M G T ECP4409T D3 1888M G TS ECP4412T D3 1852M G T ECP4410T LS 1876M G T ECP4411T D M G TS ECP4413T D3 1856M G T ECP4406T LS 1888M G T ECP44156T D M G TS ECP4416T D3 1876M G T ECP4407T LS 18136M G T ECP44206T D M G TS ECP44252T D M G T ECP4408T LS 18168M G TY ECP44256T D M G TS ECP44302T D M G TY ECP44304T LS 18160M G TS ECP44352T D M G TY ECP44354T LS 18168M G LY ECP50356L D M G TS ECP44402T D M G TY ECP44404T LS 18180M G with Roller Bearings T ECP44156TR D M G T ECP4407TR D M G TY ECP44206TR D M G TY ECP4408TR D M G TY ECP44256TR D M G TY ECP44304TR D M G SHADED RATINGS ARE CAST IRON FRAMES Explosion Proof Pump Commercial 52

53 Three Phase - Super-E Volts, Rigid Base Severe Duty 1 thru T thru 445T Meets NRC Canadian standards for efficiency. General Information Applications: Petro-chemical plants, mines, foundries, pulp and paper plants, waste management facilities, chemical plants, tropical climates and other processing industry applications requiring protection against corrosion caused by severe environmental operating conditions. Single Phase Features: 1.15 S. F. Corrosion resistant epoxy finish. Regreasable ball bearings. Oversized rotatable cast iron conduit box. Forsheda shaft seal. Moisture resistant ISR copper windings. Class F insulation. Stainless steel nameplate and corrosion resistant hardware. Tropicalized. Premium efficiency and 3 Year Warranty. General Purpose 60 Hz T ECP3581T L1 0524M H / T ECP3584T L1 0528M H T ECP3587T L1 0532M H T ECP3661T L1 0628M H T ECP3764T L1 0736M H T ECP3665T L1 0643M H T ECP3768T L1 0744M H / T ECP3770T L1 0740M H / T ECP2276T L1 0954M H T ECP3774T L1 0750M H T ECP2332T L1 0960M H T ECP2333T L1 0936M H T ECP4100T L1 1054M H T ECP2334T L1 0952M H T ECP4102T L1 1060M H T ECP4103T L1 1046M H T ECP4111T L1 1248M H T ECP4104T L1 1060M H T ECP4110T L1 1260M H T ECP4115T L1 1266M H T ECP4314T L1 1462M H T ECP4316T L1 1482M H T ECP4400T LS 1684M H T ECP4410T LS 1876M H T ECP4406T LS 1888M H T ECP4407T LS 18136M H NOTE: 60 Hz: H = 575 volts. See notes on pages 8 and 9, and inside back flap. SHADED RATINGS ARE CAST IRON FRAMES Type C Dimension Volt Code Amps Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Explosion Proof Commercial Pump 53

54 General Information Single Phase General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Explosion Proof Pump Commercial Three Phase & 230/460 Volts - C-Face 60 Hz. NOTE: 60 Hz: E = /460 volts, E1 = 230/460 volts usable at 208 volts, G = 460 volts. See notes on pages 8 and 9, and inside back flap. Severe Duty 1 thru 25 56C thru 326TC Applications: Petro-chemical plants, mines, foundries, pulp and paper plants, waste management facilities, chemical plants, tropical climates and other processing industry applications requiring corrosion protection from severe environmental operating conditions. Features: 1.15 Service Factor, corrosion resistant epoxy finish, regreasable ball bearings, oversized rotatable cast iron conduit box, cast iron frames, Forsheda shaft seal, moisture resistant copper windings, Class F insulation, tropicalization, stainless steel nameplate and corrosion resistant hardware. VECP and CECP Super-E motors have Premium efficiency and 3 year warranty. Type C Dimension C-Face less Base C VECP K 0516M G C VCP K 0513M G C VECP K 0524M E C VECP K 0524M G C VCP K 0516M E C VCP K 0516M G TC VECP3581T 687 L1 0524M E TC VECP3681T L1 0524M G TC VCP3581T 454 L1 0518M E TC VCP3581T L1 0516M G TC VECP3582T 757 L1 0528M E TC VCP3582T 660 L1 0526M E / TC VECP3583T L1 0524M G / TC VCP3583T L1 0516M G / TC VECP3584T 700 L1 0528M E / TC VECP3584T L1 0528M G / TC VCP3584T 571 L1 0524M E / TC VCP3584T L1 0520M G / TC VECP3667T 900 L1 0634M E / TC VCP3667T 774 L1 0625M E TC VECP3586T L1 0532M G TC VCP3586T L1 0524M G TC VECP3587T 729 L1 0532M E TC VECP3587T L1 0532M G TC VCP3587T 584 L1 0528M E TC VCP3587T L1 0528M G TC VECP3664T 912 L1 0640M E TC VCP3664T 723 L1 0632M E TC VECP3660T L1 0628M G TC VCP3660T L1 0620M G TC VECP3661T 936 L1 0628M E TC VECP3661T L1 0628M G TC VCP3661T 830 L1 0628M E TC VCP3661T L1 0623M G TC VECP3764T 1347 L1 0736M E TC VCP3764T 1154 L1 0729M E 5.1 Volt Code Amps SHADED RATINGS ARE CAST IRON FRAMES 54

55 Three Phase & 230/460 Volts - C-Face continued Severe Duty General Information 60 Hz. NOTE: 60 Hz: E1 = 230/460 usable at 208 volts, G = 460 volts. See notes on pages 8 and 9, and inside back flap. Type C Dimension TC VECP3663T L1 0634M G TC VCP3663T L1 0628M G TC VECP3665T 952 L1 0643M E TC VECP3665T L1 0643M G TC VCP3665T 855 L1 0634M E TC VCP3665T L1 0634M G TC VECP3768T 1363 L1 0744M E / TC VECP3769T L1 0733M G / TC VCP3769T L1 0723M G / TC VECP3770T 1238 L1 0740M E / TC VECP3770T L1 0740M G / TC VCP3770T 1177 L1 0735M E / TC VCP3770T L1 0735M G / TC VECP2276T 2137 L1 0954M E / TC VCP2276T 1662 L1 0940M E TC VECP3771T L1 0744M G TC VCP3771T L1 0735M G TC VECP3774T 1462 L1 0750M E TC VECP3774T L1 0750M G TC VCP3774T 1267 L1 0740M E TC VCP3774T L1 0740M G TC VECP2332T 2676 L1 0960M E TC VCP2332T 2212 L1 0936M E TC VECP2333T 2065 L1 0936M E TC VCP2333T 1880 L1 0938M E TC VECP4100T 3155 L1 1054M E TC VCP4100T 3111 L1 0960M E TC VECP2334T 2191 L1 0948M E TC VCP2334T 2056 L1 0938M E TC VECP4102T 4118 L1 1060M E TC VCP4102T 3547 L1 1042M E TC VECP4103T 2900 L1 1046M E TC VCP4103T 2559 L1 0956M E TC VECP4111T 4334 L1 1256M E TC VCP4111T 4277 L1 1252M E C-Face with Base TC CECP3581T 692 L1 0524M E / TC CECP3584T 705 L1 0528M E TC CECP3587T 734 L1 0532M E TC CECP3661T 947 L1 0628M E TC CECP3665T 962 L1 0643M E / TC CECP3770T 1259 L1 0740M E TC CECP3774T 1483 L1 0750M E TC CECP2333T 2107 L1 0936M E TC CECP2334T 2233 L1 0952M E TC CECP4103T 2952 L1 1046M E TC CECP4104T 3408 L1 1060M E TC CECP4110T 4349 L1 1260M E TC CECP4115T 5005 L1 1266M E Volt Code Amps SHADED RATINGS ARE CAST IRON FRAMES Single Phase General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Explosion Proof Pump Commercial 55

56 General Information Single Phase General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Explosion Proof Pump Commercial Three Phase - IEEE Volts, Rigid Base and C-Face 60 Hz. Severe Duty 1 thru T thru 449T Applications: Petro-chemical, pulp and paper plants, mines and other installations requiring premium efficient motors manufactured and tested to rigid standards for severe duty service. Features: Exceeds IEEE standards for severe duty TEFC induction motors. Premium efficiency copper windings using Baldor ISR (Inverter Spike Resistant ) magnet wire. Inpro/Seal VBX bearing isolator on fan and drive end shaft extensions, 2-part epoxy primer (inside & outside), gray epoxy paint and corrosion resistant hardware. Reduced noise, vibration and mechanical tolerances; final test and vibration results shipped with motor. Complies with Premium efficiency guidelines. 5 year warranty T ECP83580T L1 0516M G T ECP83581T L1 0524M G T ECP83582T L1 0528M G / T ECP83583T L1 0524M G / T ECP83584T L1 0528M G / T ECP83667T L1 0632M G T ECP83586T L1 0532M G T ECP83587T L1 0532M G T ECP83664T L1 0640M G T ECP83660T L1 0628M G T ECP83661T L1 0628M G T ECP83764T L1 0736M G T ECP83663T L1 0634M G T ECP83665T L1 0643M G T ECP83768T L1 0744M G / T ECP83769T L1 0733M G / T ECP83770T L1 0740M G / T ECP82276T L1 0954M G T ECP83771T L1 0744M G T ECP83774T L1 0750M G T ECP82332T L1 0960M G T ECP82394T L1 0934M G T ECP82333T L1 0936M G T ECP84100T L1 1054M G T ECP84106T L1 0944M G T ECP82334T L1 0952M G T ECP84102T L1 1060M G TS ECP84107T L1 1038M G T ECP84103T L1 1046M G T ECP84111T L1 1256M G TS ECP84108T L1 1042M G T ECP84104T L1 1060M G T ECP84117T L1 1260M G TS ECP84109T L1 1244M G T ECP84110T L1 1260M G T ECP84308T L1 1468M G TS ECP84114T L1 1252M G T ECP84115T L1 1266M G T ECP84312T L1 1474M G 61.0 NOTE: 60 Hz: G = 460 volts. See notes on pages 8 and 9, and inside back flap. SHADED RATINGS ARE CAST IRON FRAMES Type C Dimension Volt Code Amps 56

57 Severe Duty Three Phase - IEEE Volts, Rigid Base and C-Face continued General Information 60 Hz. NOTE: 60 Hz: G = 460 volts. See notes on pages 8 and 9, and inside back flap. (1) ECP84408T-4 does not meet Premium efficiency. A custom motor is available. Type C Dimension TS ECP84310T L1 1458M G T ECP84314T L1 1462M G T ECP84403T D3 1672M G TS ECP84313T L1 1472M G T ECP84316T L1 1482M G T ECP84404T D3 1680M G TS ECP84402T D3 1658M G T ECP84400T D3 1684M G T ECP84409T D3 1888M G TS ECP84412T D3 1852M G T ECP84410T D3 1876M G T ECP84411T L M G TS ECP84413T D3 1876M G T ECP84406T D3 1888M G T ECP844156T D M G TS ECP84416T D3 1876M G T ECP84407T D M G T ECP844206T D M G TS ECP844252T D M G T ECP84408T-4 (1) D M G T ECP844256T D M G C-Face with Base TC CECP83580T L1 0516M G TC CECP83581T L1 0524M G / TC CECP83583T L1 0524M G / TC CECP83584T L1 0528M G TC CECP83586T L1 0532M G TC CECP83587T L1 0532M G TC CECP83660T L1 0628M G TC CECP83661T L1 0628M G TC CECP83663T L1 0634M G TC CECP83665T L1 0643M G / TC CECP83769T L1 0733M G / TC CECP83770T L1 0740M G TC CECP83771T L1 0744M G TC CECP83774T L1 0750M G TC CECP82394T L1 0934M G TC CECP82333T L1 0936M G TC CECP84106T L1 0944M G TC CECP82334T L1 0952M G TSC CECP84107T L1 1038M G TC CECP84103T L1 1046M G TSC CECP84108T L1 1042M G TC CECP84104T L1 1060M G TSC CECP84109T L1 1244M G TC CECP84110T L1 1260M G TSC CECP84114T L1 1252M G TC CECP84115T L1 1266M G TSC CECP84310T L1 1458M G TC CECP84314T L1 1462M G TSC CECP84313T L1 1472M G TC CECP84316T L1 1482M G 86.5 Volt Code Amps SHADED RATINGS ARE CAST IRON FRAMES Single Phase General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Explosion Proof Pump Commercial 57

58 General Information Single Phase General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Explosion Proof Three Phase - IEEE Volts, Rigid Base 60 Hz. NOTE: 60 Hz: H = 575 volts. See notes on pages 8 and 9, and inside back flap. (1) ECP84408T-4 does not meet Premium efficiency. A custom motor is available. Severe Duty 1 thru T thru 449T Meets NRC Canadian standards for efficiency. Applications: Petro-chemical, pulp and paper plants, mines and other installations requiring premium efficient motors manufactured and tested to rigid standards for severe duty service. Features: Exceeds IEEE standards for severe duty TEFC induction motors. Premium efficiency copper windings using Baldor ISR (Inverter Spike Resistant ) magnet wire. Inpro Seal on fan and drive end shaft extensions, 2-part yellow epoxy oxide primer (inside & outside), gray epoxy paint and corrosion resistant hardware. Reduced noise, vibration and mechanical tolerances; final test and vibration results shipped with motor. Complies with Premium efficiency guidelines. 5 year warranty. Type C Dimension T ECP83581T L1 0524M H / T ECP83584T L1 0530M H T ECP83587T L1 0532M H T ECP83661T L1 0628M H T ECP83665T L1 0643M H / T ECP83770T L1 0740M H T ECP83774T L1 0750M H T ECP82333T L1 0936M H T ECP82334T L1 0952M H T ECP84103T L1 1046M H T ECP84104T L1 1060M H T ECP84110T L1 1260M H T ECP84115T L1 1266M H T ECP84314T L1 1462M H T ECP84316T L1 1482M H T ECP84400T D3 1684M H T ECP84410T D3 1876M H T ECP84406T D3 1888M H T ECP84407T D M H T ECP84408T-5 (1) D M H Volt Code Amps SHADED RATINGS ARE CAST IRON FRAMES Pump Commercial 58

59 Three Phase - Medium Voltage /4160 Volts, Rigid Base 60 Hz. Severe Duty 200 thru TS thru 5011L Applications: Petro-chemical plants, mines, foundries, pulp and paper plants, waste management facilities, chemical plants, tropical climates and other processing industry applications requiring corrosion protection from severe conditions. Features: Form coil VPI construction, copper bar rotor(1), all cast iron, Premium efficiency three year warranty. NOTE: 60 Hz: O = 2300/4160 volts. All motors 449T through 5000 frame have ball bearings SHADED RATINGS ARE CAST IRON FRAMES suitable for coupled loads. If load is belted, a roller bearing may be required. Contact your local Baldor office. with 5007SY, 5009SY and 5011LY have non-standard BA due to drive end bearing cooling fan. Please refer to layout drawing. (1) Copper bar rotor standard on 5000 frame motors only. See notes on pages 8 and 9, and inside back flap. Custom TEFC motors available through 900 ; Open and WPII motors through Contact your Baldor Sales Representative. Type C Dimension TS ECP44202T D M O T ECP44204T D M O SY ECP50252S D M O L ECP50254L D M O L ECP50256L D M O SY ECP50302S D M O L ECP50304L D M O LY ECP50306L D M O LY ECP50354L D M O LY ECP50356L D M O SY ECP50402S D M O LY ECP50404L D M O LY ECP50406L D M O LY ECP50454L D M O LY ECP50456L D M O SY ECP50502S D M O LY ECP50504L D M O LY ECP50506L D M O 65.0 Volt Code Amps General Information Single Phase General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Commercial Pump Explosion Proof 59

60 General Information Single Phase Three Phase - Quarry Duty - TEFC, Design C, High Torque Severe Duty 1 thru 15 56C thru 254T Applications: Conveyors, gear reducers and applications requiring Design C torques. Features: Cast iron frame, Class F insulation, Class B rise. UL and CSA recognized component approval. General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Explosion Proof Pump Commercial Hz. NOTE: 60 Hz: E = /460, E1 = 230/460 volt, usable on 208 volt, F = 230/460 volts. See notes on pages 8 and 9, and inside back flap. Three Phase - Crusher -TEFC, 460 Volt, Rigid Base NOTE: 60 Hz: G= 460. See notes on pages 8 and 9, and inside back flap. 449TY is non-standard BA due to drive end bearing cooling fan. Type C Dimension Foot Mount - Rigid Base T M3558T L1 3528M E T M3611T L1 3623M E T M3615T L1 3640M F / T M3710T L1 3735M F T M3714T L1 3742M F T M2333T L1 0934M E C-Face less Base C VM K 0516M E TC VM3581T 428 L1 0516M E / TC VM3584T 433 L1 0520M E TC VM3587T 461 L1 0528M E TC VM3661T L1 0623M F TC VM3665T L1 0634M F Hz. Volt Code 100 thru T thru 449T Amps Applications: Belt-driven rock crushers, pellet mills, and other applications requiring motors rated for severe duty service and high starting torques. Features: High torque design exceeds Design C locked rotor, pull up, and breakdown torques Service Factor. Corrosion resistant epoxy finish. Regreasable bearings. Oversize, rotatable cast iron conduit box. Forsheda shaft seal. Moisture resistant copper windings with Class F tropicalized insulation. Stainless steel nameplate and corrosion resistant hardware. Pulley end roller bearings and high strength steel shaft for belted loads only; not suitable for direct coupled loads. Type SHADED RATINGS ARE CAST IRON FRAMES C Dimension T CR4400TR L1 1672M G T CR4409TR L1 1896M G T CR4410TR L1 1884M G T CR4411TR L M G T CR4406TR L1 1896M G T CR44156TR L M G T CR4407TR L M G TY CR44206TR L M G TY CR4408TR L M G TY CR44256TR L M G TY CR44306TR D M G Volt Code Amps SHADED RATINGS ARE CAST IRON FRAMES

61 Three Phase - Severe Duty 1/2 thru thru 256T General Information 60 Hz. Applications: Petro-chemical plants, mines, foundries, pulp and paper plants, waste management facilities, chemical plants, tropical climates and other processing industry applications requiring corrosion protection from severe conditions. Features: 1.0 Service Factor at 50 C ambient, weatherproof per IEEE 45 and USCG 259 marine duty (below deck duty only). 416 stainless steel shaft for corrosion protection from severe conditions. Foot Mount - Rigid Base 1/ M K 3416M E / M K 3420M E M K 3426M E T M8003T 597 L1 0518M E / T M8004T 584 L1 0524M E T M8005T 618 L1 0528M E T M8006T 801 L1 0628M E T M8007T 901 L1 0638M E / T M8008T 1099 L1 0735M E T M8009T 1305 L1 0740M E T M8010T 1867 L1 0756M F T M8014T 2270 L1 0938M E C-Face, No Drip Cover, less Base 1/ C VM K 3416M E / C VM K 3420M E C VM K 3416M E C VM K 3426M E TC VM8003T 565 L1 0516M E / C VM K 3520M E / TC VM8004T 554 L1 0520M E TC VM8016T 622 L1 0524M E TC VM8005T 585 L1 0528M E TC VM8006T 796 L1 0623M E TC VM8007T 889 L1 0634M E / TC VM8008T 1148 L1 0735M E TC VM8024T 1291 L1 0740M E 13.5 NOTE: 60 Hz: E = /460 volts, E1= 230/460 usable at 208 volts, F= 230/460 volts. SHADED RATINGS ARE CAST IRON FRAMES See notes on pages 8 and 9, and inside back flap. Dirty duty not recommended for a chlorine atmosphere. Type C Dimension Volt Code Amps Single Phase General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Explosion Proof Commercial Pump 61

62 General Information Single Phase General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Explosion Proof Pump Commercial 62 Single and Three Phase - TENV and TEFC 60 Hz. NOTE: 60 HZ: E = /460 Volts, B1= 115/230 usable at 208 volts, E1=230/460 usable at 208 volts, F = 230/460 volts. See notes on pages 8 and 9, and inside back flap. Washdown Duty 1/2 thru 20 56/56C thru 256TC Applications: Food processing and other applications that regularly expose the motor to high pressure wash down. Features: 300 series stainless steel hardware, moisture sealant on bolt heads, between frame and endplates. Neoprene gaskets. Double sealed bearings. Forsheda running contact v-ring slinger. Stainless steel shaft extension. Electrostatically applied epoxy finish. Class F insulation. Tropicalized. EWDM, CEWDM and VEWDM Super-E motors have Premium efficiency and 3 year warranty. Type C Dimension Single Phase, C-Face with Base 1/ C CWDL K 3520L B / C CWDL K 3520L B C CWDL K 3520L B C CWDL K 3524L B / C CWDL K 3524L B / C CWDL K 3532LC B1 8.0 Single Phase, C-Face less Base 1/ C VWDL K 3520L B / C VWDL K 3520L B C VWDL K 3524L B / C VWDL K 3532LC B1 8.0 Three Phase, Rigid Base 1/ WDM K 3516M E / WDM K 3520M E T EWDM3546T 562 L1 3526M E T WDM3546T 433 L1 3524M E / T EWDM3554T 616 L1 3532M E / T WDM3554T 473 L1 3535M E T EWDM3558T 811 L1 3532M E T WDM3558T 589 L1 3528M E T EWDM3611T 1013 L1 3628M E T WDM3611T 779 L1 3628M E T EWDM3615T 1154 L1 3643M E T WDM3615T 889 L1 3634M E / T EWDM3710T 1445 L1 3744M E / T WDM3710T 1110 L1 3735M E T EWDM3714T 1728 L1 3750M E T WDM3714T 1329 L1 3740M E 14.2 Three Phase, C-Face with Base 1/ C CWDM K 3513M E 0.9 1/ C CWDM K 3516M E / C CWDM K 3524M E / C CWDM K 3518M E / C CWDM K 3520M E / C CWDM K 3532M E C CWDM K 3516M F C CWDM K 3524M E TC CEWDM3546T 647 L1 3526M E TC CWDM3546T 499 L1 3524M E C CEWDM K 3528M E C CWDM K 3524M E 1.7 Volt Code Amps

63 Single and Three Phase - TENV and TEFC continued 60 Hz. NOTE: 60 Hz: E = /460 Volts, E1= 230/460 usable at 208 volts, F = 230/460 volts. See notes on pages 8 and 9, and inside back flap. Red catalog number = New item Type Washdown Duty C Dimension 1 1/ C CEWDM K 3524M E / C CWDM K 3516M F / TC CEWDM3554T 676 L1 3532M E / C CWDM K 3520M E / TC CWDM3554T 519 L1 3535M E / C CWDM K 3528M F HCY CEWDM K 3532M E HCY CWDM K 3524M E TC CWDM3555T 616 L1 3526M E C CWDM K 3528M E TC CEWDM3558T 834 L1 3532M E TC CWDM3558T 642 L1 3528M E TC CWDM3614T 787 L1 3632M E TC CWDM3559T 758 L1 3535M E TC CWDM3610T 836 L1 3535M E TC CEWDM3611T 1096 L1 3628M E TC CWDM3611T 844 L1 3628M E TC CWDM3704T 1039 L1 3729M E TC CWDM3613T 1057 L1 3630M E TC CEWDM3615T 1241 L1 3643M E TC CWDM3615T 954 L1 3634M E TC CWDM3708T 1229 L1 3735M E / TC CWDM3616T 1206 L1 3640M E / TC CWDM3709T 1311 L1 3640M E / TC CEWDM3710T 1571 L1 3744M E / TC CWDM3710T 1209 L1 3735M E / TC CWDM22976T 2059 L1 3930M E TC CWDM3711T 1556 L1 3732M E TC CEWDM3714T 1787 L1 3750M F TC CWDM3714T 1374 L1 3740M E TC CWDM23932T 2251 L1 3936M E TC CWDM3713T 1916 L1 3750M E TC CWDM23994T 2547 L1 3750M E TC CEWDM23933T 3259 L1 3942M F TC CWDM23933T 2507 L1 3940M E TC CWDM41906T 2925 L1 3948M E TC CEWDM23934T 3781 L1 3952M F TC CWDM23934T 2909 L1 3952M E Three Phase, C-Face less Base 1/ C VWDM K 3516M E / C VWDM K 3520M E C VEWDM K 3532M F C VWDM K 3524M E TC VEWDM3546T 631 L1 3532M F TC VWDM3546T 496 L1 3524M E / C VEWDM K 3532M E / C VWDM K 3535M E / TC VEWDM3554T 673 L1 3532M E / TC VWDM3554T 517 L1 3535M E C VEWDM K 3532M E C VWDM K 3528M E TC VEWDM3558T 766 L1 3532M E TC VWDM3558T 589 L1 3528M E TC VEWDM3611T 1002 L1 3628M E TC VWDM3611T 771 L1 3535M E TC VEWDM3615T 1241 L1 3643M E TC VWDM3615T 875 L1 3634M E 6.6 Volt Code Amps General Information Single Phase General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Explosion Proof Pump Commercial 63

64 General Information Single and Three Phase - TENV and TEFC continued Washdown Duty Single Phase General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty 60 Hz. NOTE: 60 Hz: E = /460 Volts, H = 575 volts, E1= 230/460 usable at 208 volts. See notes on pages 8 and 9, and inside back flap. Three Phase - Super-E Washdown Brake - TEFC and TENV Type C Dimension Three Phase, C-Face less Base continued / TC VEWDM3710T 1557 L1 3744M E / TC VWDM3710T 1109 L1 3729M E TC VEWDM3714T 1636 L1 3750M E TC VWDM3714T 1258 L1 3740M E 13.0 Three Phase, 575 Volt, C-Face with Base 1/ C CWDM K 3516M H 0.6 3/ C CWDM K 3520M H C CWDM K 3524M H / TC CWDM3554T L1 3535M H TC CWDM3558T L1 3528M H TC CWDM3611T L1 3628M H TC CWDM3615T L1 3634M H 5.7 Volt Code 1 thru 10 56C thru 184TC Amps Applications: Food processing and other applications that regularly expose the motor to high pressure washdown. Features: Standard BA dimension 300 series stainless steel hardware, moisture sealant on bolt heads, between frame and end plates. Neoprone gaskets. Spring set brake internally connected to the motor. Power off manual release. Resets automatically. have Premium Efficiency and inverter-ready. 230/460V brakes are connected in conduit box allowing for separate connection when used with an inverter. Washdown Duty Explosion Proof Pump Commercial 60 Hz. Type C Dimension NOTE: 60 Hz: E = /460 Volts, E1=230/460 usable at 208 volts, F = 230/460 volts, 60 Hz. 1 Amps at 460V - double for 230V. Efficiencies shown are nominal. Data subject to change without notice. Contact Baldor for certified data. Volt Code Amps 1/ C CEWDBM K 3516M F / C CEWDBM K 3518M F C CEWDBM K 3526M E TC CEWDBM3546T 1370 L1 3526M E / TC CEWDBM3554T 1438 L1 3532M E TC CEWDBM3558T 1595 L1 3532M E TC CEWDBM3611T 1984 L1 3628M E TC CEWDBM3615T 2378 L1 3643M E Brake Rating 64

65 Three Phase - Washdown 60 Hz. TM Washdown Duty 1/2 thru 10 56C thru 215TC Applications: The most severe and corrosive applications, those which use intense high-pressure washdown, and marine applications. Features: Proprietary bonded surface coating, stainless steel shaft extension, non-contact rotating labyrinth shaft seal on drive and fan ends, threaded drain ports, stainless steel plugs, gasketed and sealed conduit box, FDA approved surface coating. Weatherproof per IEEE45 and USCG259 marine duty (below deck duty only). C-Face with Base 1/ C CWAM K 3516M E / C CWAM K 3520M E C CWAM K 3516M E C CWAM K 3524M E TC CWAM3546T 574 L1 3524M E C CWAM K 3524M E / TC CWAM K 3520M E / TC CWAM3554T 597 L1 3535M E / C CWAM K 3528M F C CWAM K 3520M E C CWAM K 3528M E TC CWAM3558T 738 L1 3528M E TC CWAM3614T 1012 L1 3632M E TC CWAM3559T 865 L1 3535M E TC CWAM3611T 970 L1 3628M E TC CWAM3704T 1264 L1 3729M E TC CWAM3613T 1085 L1 3630M E TC CWAM3615T 1097 L1 3634M E TC CWAM3708T 1625 L1 3735M E / TC CWAM3616T 1396 L1 3640M E / TC CWAM3710T 1391 L1 3735M E / TC CWAM22976T 2479 L1 3940M E TC CWAM3711T 1649 L1 3732M E TC CWAM3714T 1570 L1 3740M E TC CWAM23932T 2718 L1 3946M E 15.3 C-Face less Base 1/ C VWAM K 3516M E 0.8 3/ C VWAM K 3520M E C VWAM K 3524M E TC VWAM3546T 561 L1 3524M E / C VWAM K 3535M E / TC VWAM3554T 585 L1 3535M E C VWAM K 3528M E TC VWAM3558T 726 L1 3528M E TC VWAM3611T 944 L1 3535M E TC VWAM3615T 1073 L1 3634M E / TC VWAM3710T 1360 L1 3735M E TC VWAM3714T 1541 L1 3740M E 13.0 NOTE: 60 Hz: E = /460 Volts, E1=230/460 usable at 208 volts. See notes on pages 8 and 9, and inside back flap. Red catalog number = New item Type C Dimension Volt Code Amps General Information Single Phase General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Explosion Proof Pump Commercial 65

66 General Information Three Phase - Feather Picker - TEFC 2 thru 3 145T Applications: Food processing. Washdown Duty Single Phase Features: Moisture resistant ISR (Inverter Spike Resistant ) 200 C magnet wire. Sealed ball bearings with moisture resistant grease. Tropicalized. General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Explosion Proof Pump Commercial T WDM3558TP 623 L1 3528M E T WDM3561TP 786 L1 3546M E 4.1 NOTE: 60 Hz: E = /460 Volts. See notes on pages 8 and 9, and inside back flap. Three Phase - Paint-Free - TEFC and TENV 60 Hz. 60 Hz. 1/2 thru 10 56C thru 215TC Applications: Food processing, packaging and outdoor applications. Features: Moisture resistant ISR (Inverter Spike Resistant ) 200 C magnet wire. Sealed ball bearings with moisture resistant grease. Rotating noncontact labyrinth seal on output shaft extension and contact lip seals on fan shaft extension. Neoprene gaskets. Special processed cast endplates. 300 Series stainless steel motor frame, base, shaft and hardware. No exterior paint. Tropicalized. CESWDM and VESWDM Super-E motors have Premium efficiency and 3 year warranty TC VSWDM3558T 658 L1 3528M E 3.1 NOTE: 60 Hz: E = /460 Volts, E1= 230/460 usable at 208 volts, F = 230/460 volts. See notes on pages 8 and 9, and inside back flap. Red catalog number = New item Type Type C Dimension C Dimension C-Face with Base 1/ C CSWDM K 3516M E / C CSWDM K 3520M E C CESWDM K 3524M E C CSWDM K 3524M E TC CSWDM3546T 557 L1 3524M E / C CSWDM K 3535M E / TC CESWDM3554T 757 L1 3532T E / TC CSWDM3554T 582 L1 3535M E C CSWDM K 3528M E TC CESWDM3558T 931 L1 3532M E TC CSWDM3558T 717 L1 3528M F TC CESWDM3611T 1139 L1 3632M E TC CSWDM3611T 877 L1 3628M E TC CESWDM3615T 1326 L1 3643M E TC CSWDM3615T 1021 L1 3640M E / TC CESWDM3710T 1631 L1 3744M E / TC CSWDM3710T 1256 L1 3740M E TC CESWDM3714T 1857 L1 3756M F TC CSWDM3714T 1429 L1 3750M E 13.0 C-Face less Base 1/ C VSWDM K 3516M E / C VSWDM K 3520M E C VESWDM K 3524M E C VSWDM K 3524M E TC VSWDM3546T 552 L1 3524M E / C VESWDM K 3532M E / C VSWDM K 3535M E / TC VESWDM3554T 750 L1 3532M E / TC VSWDM3554T 578 L1 3535M E TC VESWDM3558T 857 L1 3532M E 2.7 Volt Code Volt Code Amps Amps

67 Three Phase - SSE Super-E - All Stainless Steel - TEFC and TENV 60 Hz. Washdown Duty 1/2 thru 10 56C thru 215TC Applications: Food processing, packaging, outdoor and highly corrosive environments. Features: All external surfaces 300 series stainless steel: motor frame, endplates, conduit box, shaft and base. Moisture resistant 200 C ISR magnet wire. Hydrophobic aspiration system eliminates condensation from inside the motor. Endplate rabbets have O-ring seals to band. Conduit box is welded to the motor frame. Patented bearing seal to protect motor bearings, inside and out. Epoxy encapsulation prevents any moisture from reaching the windings as well as potting the passage between the band and the conduit box. Nameplate information is laser etched on the band. numbers also etched on both sides. Especially effective in highly corrosive environments where paint or other finishes do not hold up. Premium efficiency and 3-year warranty. C-Face with Base 1/ C CSSEWDM K 3520M E 0.8 1/ C CSSEWDM K 3516M E 0.8 3/ C CSSEWDM K 3520M E 1.0 3/ C CSSEWDM K 3524M E C CSSEWDM K 3524M E C CSSEWDM K 3526M E TC CSSEWDM3546T 931 L1 3526M E / C CSSEWDM K 3532M E / TC CSSEWDM3550T 934 L1 3532M E / C CSSEWDM K 3532M E / TC CSSEWDM3554T 939 L1 3532M E TC CSSEWDM3555T 1121 L1 3535M E TC CSSEWDM3558T 1138 L1 3532M E TC CSSEWDM3559T 1365 L1 3535M E TC CSSEWDM3611T 1374 L1 3630M F TC CSSEWDM3613T 1492 L1 3634M F TC CSSEWDM3615T 1504 L1 3646M E / TC CSSEWDM3709T 1739 L1 3735M F / TC CSSEWDM3710T 1776 L1 3744M E TC CSSEWDM3711T 1975 L1 3744M E TC CSSEWDM3714T 2095 L1 3750M E C-Face less Base 1/ C VSSEWDM K 3516M E 0.8 1/ C VSSEWDM K 3520M E 0.8 3/ C VSSEWDM K 3520M E 1.0 3/ C VSSEWDM K 3524M E C VSSEWDM K 3524M E C VSSEWDM K 3526M E TC VSSEWDM3546T 915 L1 3526M E / C VSSEWDM K 3532M E / TC VSSEWDM3550T 918 L1 3532M E / C VSSEWDM K 3532M E / TC VSSEWDM3554T 923 L1 3532M E TC VSSEWDM3555T 1105 L1 3535M E TC VSSEWDM3558T 1122 L1 3532M E 2.7 NOTE: 60 Hz: E = /460 volts, E1=230/460 usable at 208 volts, F = 230/460 volts. See notes on pages 8 and 9, and inside back flap. Red catalog number = New item Type C Dimension Volt Code Amps General Information Single Phase General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Explosion Proof Pump Commercial 67

68 General Information Single Phase General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Explosion Proof Pump Commercial 68 Three Phase - All Stainless Steel - TEFC and TENV 60 Hz. NOTE: 60 Hz: E = /460 Volts, E1=230/460 usable at 208 volts, F = 230/460 volts. See notes on pages 8 and 9, and inside back flap. Washdown Duty 1/2 thru 10 56C thru 215TC Applications: Food processing, packaging, outdoor and highly corrosive environments. Features: All external surfaces 300 series stainless steel: motor frame, endplates, conduit box, shaft, and base. Moisture resistant 200 C ISR magnet wire. Four condensate drains in each endplate. Endplate rabbets sealed and conduit box gasketed. Lip seals. Especially effective in highly corrosive environments where paint or other finishes do not hold up. CESSWDM Super-E motors have Premium efficiency and 3 year warranty. See page 67 for Super-E all stainless motors. Type C Dimension C-Face with Base 1/ C CSSWDM K 3513M E 0.9 1/ C CSSWDM K 3516M E / C CSSWDM K 3518M E / C CSSWDM K 3524M E C CSSWDM K 3516M F C CSSWDM K 3524M E / C CSSWDM K 3528M F / C CSSWDM K 3528M E / TC CSSWDM3554T 896 L1 3528M E TC CSSWDM3555T 1078 L1 3532M E C CSSWDM K 3528M F TC CSSWDM3558T 1089 L1 3528M F TC CSSWDM3559T 1298 L1 3535M E TC CESSWDM3611T 1309 L1 3630M F TC CSSWDM3611T 1245 L1 3628M E TC CESSWDM3613T 1524 L1 3634M F TC CSSWDM3613T 1419 L1 3634M E TC CESSWDM3615T 1474 L1 3646M E TC CSSWDM3615T 1430 L1 3640M E / TC CESSWDM3709T 1788 L1 3735M F / TC CSSWDM3709T 1653 L1 3733M E / TC CESSWDM3710T 1844 L1 3744M E / TC CSSWDM3710T 1688 L1 3740M E TC CESSWDM3711T 1996 L1 3744M E TC CSSWDM3711T 1877 L1 3740M E TC CESSWDM3714T 2035 L1 3750M E TC CSSWDM3714T 1907 L1 3750M E 13.0 C-Face less Base 1/ C VSSWDM K 3513M E 0.9 1/ C VSSWDM K 3516M E / C VSSWDM K 3518M E / C VSSWDM K 3524M E C VSSWDM K 3516M F C VSSWDM K 3524M E / C VSSWDM K 3528M F / TC VSSWDM3554T 878 L1 3528M E TC VSSWDM3555T 1060 L1 3532M E TC VSSWDM3558T 1072 L1 3528M F TC VSSWDM3559T 1280 L1 3535M E TC VSSWDM3611T 1216 L1 3628M E TC VSSWDM3613T 1391 L1 3634M E TC VSSWDM3615T 1401 L1 3640M E 6.5 Volt Code Amps

69 Three Phase - Inverter Ready, Paint Free Washdown - TEFC and TENV, C-Face Washdown Duty 20:1 Constant Torque Speed Range 1/2 thru 10 56C thru 215TC Applications: Conveyors, Pumps and other equipment in food processing and severe environments where motors are washed on a regular basis. Features: Includes all the advantages of our standard Paint Free washdown duty motors. Specifically designed and built for use on adjustable speed drives. For adjustable speed applications not requiring full torque at zero speed. Not encoder adaptable. General Information Single Phase General Purpose 60 Hz. Max TC IDVSWDM3611T 1426 E2 3628M F TC IDVSWDM3615T 1663 E2 3640M F 6.5 NOTE: 60 Hz: E = /460 volts, F= 230/460 volts. Type C Dimension C-Face with Base 1/ C IDCSWDM E2 3516M F 0.8 3/ C IDCSWDM E2 3524M F /2 1 1/2 2 2 Volt Code C IDCSWDM E2 3524M E TC IDCSWDM3546T 1148 E2 3524M E C IDCSWDM E2 3528M F TC IDCSWDM3554T 1228 E2 3528M F C IDCSWDM E2 3535M F TC IDCSWDM3558T 1311 E2 3535M F TC IDCSWDM3611T 1438 E2 3628M F TC IDCSWDM3615T 1674 E2 3640M F / TC IDCSWDM3710T 2536 E2 3740M F TC IDCSWDM3714T 2899 E2 3750M F 13.0 C-Face less Base 1/ C IDVSWDM E2 3516M F 0.8 3/ C IDVSWDM E2 3524M F /2 1 1/ C IDVSWDM E2 3524M E TC IDVSWDM3546T 1142 E2 3524M E C IDVSWDM E2 3528M F TC IDVSWDM3554T 1221 E2 3528M F C IDVSWDM E2 3535M F TC IDVSWDM3558T 1300 E2 3535M F 2.5 Amps Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Explosion Proof Commercial Pump 69

70 General Information Single Phase Three Phase - Vector, Washdown - TENV, C-Face with Base Washdown Duty 1 thru TC thru 254TC Applications: Material handling, packaging equipment in food processing and other wet environments. Features: Designed for inverter or vector applications where up to a 1000:1 constant torque speed range is required. include HS25 encoder feedback mounting with MS connector. Meets MG1, Part 31. General Purpose Premium Efficient Super-E C-Face Industrial 60 Hz. Max. Includes 1024 Line Count Encoder TC ZDWNM3546T 1957 E2 3524M F / TC ZDWNM3554T 2056 E2 3535M F TC ZDWNM3609T 2166 E2 3628M F TC ZDWNM3611T 2273 E2 3634M F TC ZDWNM3707T 2443 E2 3735M F / TC ZDWNM22937T 3246 E2 3940M F TC ZDWNM22938T 3634 E2 3956M F 12.0 NOTE: 60 Hz: F= 230/460. See notes on pages 8 and 9, and inside back flap. Type C Dimension Volt Code Amps Severe Duty Washdown Duty Explosion Proof Pump Commercial Stainless Steel Brushless AC Servo - SSBSM Series Cont. Stall Torque (Lb-In) Cont. Stall Amps Nominal Bus Volts BISSC/UL/CSA/CE 3.9 thru 100 lb-in Torque (.45 thru 11.3 Nm) Applications: Designed for harsh, corrosive, or food/liquid, high hygiene environments. Pharmaceutical, washdown, packaging, food handling, beverage & dairy processing applications. Durable to handle IP67 and 1500 psi washdown conditions. Features: All stainless steel to provide protection in harsh environments and washdown conditions. Reliable potted stator provides environmental, current spike and high voltage protection. Grease proven to provide 4 times greater life. Insulation UL rated and potted for extra high insulation/safety. Teflon stainless steel seal with Viton D-rings. Laser etched nameplate. Speed () Inertia (Lb-In-Sec 2 ) SSBSM50N-175CA 1860 E SSBSM63N-375CA 2592 E SSBSM80C-175CA 1902 E SSBSM80C-275CA 1949 E SSBSM80C-475CA 2005 E SSBSM90C-3150CA 2295 E SSBSM100C-3150CA 3030 E4 NOTE: Standard SSBSM series includes IEC mounting flange. Standard SSBSM50 has as standard no keyway and no tap on shaft end. Standard SSBSM50/63/80/90/100 include two threaded stainless steel connectors for feedback and motor termination. Order feedback and power cables separately. 70

71 Single and Three Phase - Rigid Base Explosion Proof 1/4 thru thru 449T Applications: Ideal for use where hazardous fumes or dust may be present. General Information 60 Hz. Features: U.L. and CSA approved for Class I Group D and Class I Group C and D and Class II Group F and G. Check number in circle beside catalog number for individual listings. Corrosion resistant epoxy finish. Shipped with U.L. and CSA approved cast conduit box assembled to each motor Service Factor. EM Super-E explosion-proof motors have Premium efficiency and 3 year warranty. NOTE: 60 Hz: A= 115/ , B= 115/230, C= 230, E= / //60 Hz: U= 190/380//230/460 volts, 50//60 Hz. See notes on pages 8 and 9, and inside back flap. 1 = Class I, Group D ONLY, T2C. 2 = Class I, Group C & D, Class II, Group F & G, T4. 7 = Class I, Group D, Class II, Group F & G, T4. 8 = Class I, Group D, Class II, Group F & G, T3C. Type C Dimension 1/ L4003A K X3411L A 2.5 1/ L5000A K X3411L B 2.5 1/ L4005A K X3413L B 3.0 1/ L4006A K X3414L A 3.0 1/ L5001A K X3414L A 3.0 1/ L5002A K X3520L B 3.4 1/ L5003A K X3416L B 3.7 1/ L4009A K X3424L A 3.7 1/ L5004A K X3424L A 3.7 1/ L5005A K X3528L B 4.0 3/ L5006A K X3516L B 4.9 3/ L5007A K X3524L B 5.3 3/ L K X3535L B L5009A K X3524L B L5023A K X3524L B T L5023T L1 X3524L A L L1 X3634L A / T L5030T L1 X3528L A / L L1 X3628L B T L5031T L1 X3535L A T L5027T L1 X3634L B T L5028T L1 X3634L B L L1 X3735L B L L1 X3744LC C 21.0 Three Phase 1/ M6002A K X3410M E 0.7 1/ M7002A K X3413M E 0.8 1/ M7003A K X3513M E 0.8 1/ M7005A K X3410M E 1.1 1/ M6007A K X3416M E 1.0 1/ M7006A K X3416M E 1.0 1/ M7007A K X3516M E 1.2 3/ M7009A K X3413M E 1.3 3/ M7010A K X3420M E 1.5 3/ M7031A K X3524M E 1.4 3/ T M7031TA L1 X3524M E M K X3416M E M K X3516M T T EM7014T L1 X3524M U T M7014T LS X3518M U T EM7114T-C L1 X0524M E 1.4 Volt Code Amps Single Phase General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Explosion Proof Pump Commercial 71

72 General Information Single Phase General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Explosion Proof Pump Commercial Three Copy Phase - Rigid Base continued 60 Hz. NOTE: 60 Hz: E= /460, F=230/ //60 Hz: T=190/380// /460, U= 190/380//230/460 volts, 50//60 Hz. See notes on pages 8 and 9, and inside back flap. 1 = Class I, Group D ONLY, T2C. 2 = Class I Group C & D, Class II Group F & G, T4. 8 = Class I, Group D, Class II, Group F & G, T3C. Type Explosion Proof C Dimension T M7114T LS X0518M U M L1 X3516M T M K X3524M F T M7032T L1 X3526M F / T M7018T L1 X3520M U / M K X3520M T / T EM7034T L1 X3530M U / T M7034T LS X3524M U / T EM7134T-C L1 X0528M F / T M7134T LS X0524M E / M L1 X3520M T / T M7020T L1 X3628M U T M7071T L1 X3526M U M K X3528M E T EM7037T L1 X3532M E T M7037T LS X3528M U T EM7137T-C L1 X0532M E T M7137T LS X0528M U M L1 X3528M T T M7041T L1 X3636M U T M7075T L1 X3540M F T M7026T L1 X3620M U M L1 X3528M T T M7042T LS X3628M U T EM7142T-C L1 X0628M U T M7142T LS X0628M U M L1 X3717M U T M7036T L1 X3729M U T M7072T L1 X3634M U T EM7144T-C L1 X0643M U T M7144T LS X0638M U T M7044T LS X3638M U M L1 X3723M T T M7040T L1 X3735M U / T M7073T L1 X3640M F / T M7045T L1 X3733M U / T EM7147T-C L1 X0740M U / T M7147T LS X0735M U / T M7047T LS X3735M U / T M7048T L1 X0946M U T M7074T L1 X3735M F T M7174T L1 X0735M U T M7070T LS X3744M F T EM7170T-C L1 X0750M U T M7170T LS X0740M U T M7065T L1 X0946M U T M7053T L1 X0940M U T EM7054T-C L1 X0942M U T EM7054T L1 X0942M U T M7054T LS X0944M U T M7057T L1 X1044M U 19.5 Volt Code Amps SHADED RATINGS ARE CAST IRON FRAMES 72

73 Three Phase - Rigid Base continued Explosion Proof General Information 60 Hz. NOTE: 60 Hz: N = 380//460, 50//60 Hz, U = 190/380//230/460 volts, 50//60 Hz. See notes on pages 8 and 9, and inside back flap. 2 = Class I, Group C & D, Class II, Group F & G, T4. 7 = Class I, Group D, Class II, Group F & G, T4. 8 = Class I, Group D, Class II, Group F & G, T3C. Type C Dimension T M7059T L1 X0936M U T EM7056T-C L1 X0952M U T EM7056T L1 X0952M U T M7056T LS X0946M U T M7079T L1 X1050M U TS M7063T L1 X1040M U T EM7058T-C L1 X1050M U T EM7058T L1 X1050M U T M7058T LS X1046M U T M7082T L1 X1252M U TS M7083T L1 X1044M U T EM7060T-C L1 X1056M U T EM7060T L1 X1056M U T M7060T LS X1056M U T M7080T L1 X1256M U TS M7067T L1 X1234M U T EM7062T-C L1 X1260M U T EM7062T L1 X1260M U T M7062T LS X1256M U T M7084T L1 X1462M U TS M7081T L1 X1244M U T EM7064T-C L1 X1266M U T EM7064T L1 X1266M U T M7064T LS X1262M U T M7085T L1 X1456M U T EM7066T-C L1 X1462M U T EM7066T L1 X1462M U T M7066T LS X1462M U T M7086T L1 X1662M U T M7068T LS X1472M U T M7087T L1 X1670M U T M7090T LS X1676M U T M74124T LS X1860M N T M74154T LS X1876M N T M74204T LS X18112M N T M74254T D3 X18136M N T M74304T D3 X18160M N Volt Code Amps SHADED RATINGS ARE CAST IRON FRAMES Single Phase General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Explosion Proof Pump Commercial CAUTION: Explosion-proof motors have a tight fit between mating parts to ensure the integrity of the explosionproof enclosure. This can lead to an accumulation of moisture inside the motors due to condensation. Care should be used when selecting an explosion-proof motor, especially when installed outdoors and for intermittent duty. Consider explosion-proof motors on page 76 for outdoor applications. These explosion-proof motors are not suitable for use with adjustable speed drives, inverter duty explosion-proof motors must be used. See page 163. See notes on pages 4 and

74 General Information Single and Three Phase - C-Face Explosion Proof 1/3 thru 50 56C thru 326C Applications: Pumps, blowers, valves, etc. Single Phase Features: Corrosion resistant epoxy finish. Positively locked drive end bearing. U.L. approved cast conduit box-standard S.F. U.L. and CSA approved for Class I, Group D or Class II, Group F & G. General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Explosion Proof Pump Commercial 60 Hz. NOTE: 60 Hz: A= 115/ , B= 115/230, C= 230, E= /460, F= 230/460 volts. 50//60 Hz: T= 190/380// /460 volts, 50//60 Hz. See notes on pages 8 and 9, and inside back flap. 1 = Class I, Group D ONLY, T2C. 7 = Class I, Group D, Class II, Group F & G, T4. 8 = Class I, Group D, Class II, Group F & G, T3C. Type C Dimension Single Phase, C-Face less Base, No Drip Cover 1/ C VL5001A K X3414L A 3.0 1/ C VL5002A K X3520L B 3.4 1/ C VL5003A K X3416L B 3.7 1/ C VL5004A K X3424L A 3.7 1/ C VL5005A K X3528L B 4.0 3/ C VL5006A K X3516L B 4.9 3/ C VL5007A K X3524L B C VL5009A K X3524L B C VL5023A K X3524L B / C VL5024A K X3546L B C VL L1 X3634L A 11.0 Single Phase, C-Face with Base, No Drip Cover 1/ C CL5001A K X3414L A 3.0 1/ C CL5003A K X3416L B 3.7 1/ C CL5004A K X3424L A 3.7 3/ C CL5007A K X3524L B C CL5009A K X3524L B C CL5023A K X3524L B / TC CL5030T L1 X3528L A / C CL L1 X3628L B TC CL5031T L1 X3535L A TC CL5027T L1 X3634L B TC CL5028T L1 X3634L B C CL L1 X3735L B C CL L1 X3744LC C 21.0 Three Phase, C-Face less Base, No Drip Cover 1/ C VM7002A K X3413M E 0.8 1/ C VM7005A K X3410M E 1.1 1/ C VM7006A K X3416M E 1.0 1/ C VM7007A K X3516M E 1.2 3/ C VM7009A K X3413M E 1.3 3/ C VM7010A K X3420M E 1.5 3/ C VM7031A K X3524M E C VM K X3416M E C VM K X3428M E TC VM7014T L1 X3516M T C VM K X3524M F 1.9 Volt Code Amps 74

75 Three Phase - C-Face continued Explosion Proof General Information 60 Hz. NOTE: 60 Hz: E= /460, F=230/ //60 Hz: T= 190/380// /460, 50//60 Hz. U= 190/380//230/460 volts, 50//60 Hz. See notes on pages 8 and 9, and inside back flap. 1 = Class I, Group D ONLY, T2C. 8 = Class I, Group D, Class II, Group F & G, T3C. Type C Dimension C-Face less Base, No Drip Cover 1 1/ TC VM7018T L1 X3516M T / C VM K X3520M T / TC VM7034T L1 X3520M T / TC VM7035T L1 X3535M F TC VM7071T L1 X3524M T C VM K X3528M T TC VM7037T L1 X3528M T TC VM7075T L1 X3528M E TC VM7026T L1 X3620M T TC VM7042T L1 X3623M U TC VM7072T L1 X3628M T TC VM7044T L1 X3640M U / TC VM7073T L1 X3640M F / TC VM7045T L1 X3729M U / TC VM7047T L1 X3732M U TC VM7170T L1 X0736M U 13.3 C-Face with Base, No Drip Cover 1/ C CM7005A K X3410M E 1.1 1/ C CM7006A K X3416M E 1.0 3/ C CM7009A K X3413M E 1.3 3/ C CM7010A K X3420M E C CM K X3416M E C CM K X3516M T TC CM7014T L1 X3518M U / TC CM7018T L1 X3520M U / C CM K X3520M T / TC CM7034T L1 X3524M U TC CM7071T L1 X3526M U C CM K X3528M T TC CM7037T L1 X3528M U TC CM7075T L1 X3540M F TC CM7042T L1 X3628M U TC CM7072T L1 X3634M U TC CM7044T L1 X3638M U / TC CM7073T L1 X3640M F / TC CM7045T L1 X3733M U / TC CM7047T L1 X3735M U TC CM7174T L1 X0735M U TC CM7170T L1 X0740M U TC CM7053T L1 X0940M U TC CM7054T L1 X0944M U TC CM7059T L1 X0936M U TC CM7056T L1 X0946M U TSC CM7063T L1 X1040M U TC CM7058T L1 X1046M U TC CM7060T L1 X1056M U TC CM7062T L1 X1256M U TC CM7064T L1 X1262M U 60.0 Volt Code Amps SHADED RATINGS ARE CAST IRON FRAMES Single Phase General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Explosion Proof Pump Commercial 75

76 General Information Single Phase Three Phase Service Factor - Rigid Base Explosion Proof 3 thru T thru 405T Applications: On and off shore drill rig service, bulk fuel terminals, and transfer stations. For use in high humidity hazardous-duty applications driving pumps, compressors, blowers, fans, and many other loads that require 1.15 service factor explosion-proof motors. Designed with features for use in the petroleum industry. Includes Class 1, Group C & D approval for use in areas where hydrogen sulfide is present. General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Explosion Proof Pump Commercial Hz. NOTE: 50//60 Hz: U= 190/380//230/460 volts, 50//60 Hz, H = 575 volts. See notes on pages 8 and 9, and inside back flap. 5 = Class 1, Group C & D only, T3C. Features: Labyrinth-type recessed shaft slinger for increased bearing protection. Explosion-proof breather/drain to prevent build up of condensation. Class F insulation. Corrosion resistant finish with two part epoxy coating. UL and CSA approved for Class I, Group C & D service factor. SHADED RATINGS ARE CAST IRON FRAMES NOTE: These motors expel condensation better than standard explosion proof designs. They are recommended for applications such as fuel transfer terminals and fuel truck loading facilities where motors may run intermittently, applications where explosion-proof motors are installed outdoors exposed to the environment, and may not be operated for extended periods of time. These explosion-proof motors are not suitable for use with adjustable speed drives inverter duty explosion-proof motors must be used. See page 163. Type C Dimension Rigid Base T M7042T-I L1 X3628M U T M7042T-I L1 X3628M H T M7044T-I L1 X3638M U T M7044T-I L1 X3638M H / T M7047T-I L1 X3735M U / T M7047T-I L1 X3735M H T M7170T-I L1 X0740M U T M7170T-I L1 X0740M H T M7054T-I L1 X0944M U T M7054T-I L1 X0944M H T M7056T-I L1 X0946M U T M7056T-I L1 X0946M H T M7058T-I L1 X1046M U T M7058T-I L1 X1046M H T M7060T-I L1 X1056M U T M7060T-I L1 X1056M H T M7062T-I L1 X1256M U T M7062T-I L1 X1256M H T M7064T-I L1 X1262M U T M7064T-I L1 X1262M H T M7066T-I L1 X1462M U T M7066T-I L1 X1462M H T M7068T-I L1 X1472M U T M7068T-I L1 X1472M H T M7090T-I D3 X1676M U T M7090T-I D3 X1676M H 87.0 C-Face with Base, No Drip Cover TC CM7042T-I L1 X3628M U TC CM7044T-I L1 X3638M U / TC CM7047T-I L1 X3735M U TC CM7170T-I L1 X0740M U TC CM7054T-I L1 X0944M U TC CM7056T-I L1 X0946M U TC CM7058T-I L1 X1046M U TC CM7060T-I L1 X1056M U TC CM7062T-I L1 X1256M U TC CM7064T-I L1 X1262M U 60.0 Volt Code Amps

77 Single Phase - Jet Pump - TEFC and ODP Pump 1/3 thru 3 56C and 56J Applications: Residential and industrial pumps, swimming pool pumps, etc. General Information Features: Diecast aluminum end plates with machined steel bearing seat insert. Single Phase 60 Hz. TEFC, Stainless Steel Threaded shaft 56J less Base 1/ J JL3405A 203 K 3416L B / J JL3501A 253 K 3414L B / J JL3503A 232 K 3420L B / J JL3504A 295 K 3421L B / J JL3506A 277 K 3424L B / J JL3507A 350 K 3428LC B J JL3509A 339 K 3524L B J JL3510A 401 K 3528L B / J JL3513A 401 K 3528L B / J JL3514A 442 K 3532LC B J JL3515A 473 K 3535L B J JL3516A 503 K 3535LC B TEFC, Stainless Steel Threaded Shaft 56J with Base 1/ J CJL3501A 275 K 3414L B / J CJL3504A 324 K 3421L B / J CJL3507A 395 K 3428LC B ODP, Stainless Steel Threaded Shaft 56J less Base 1/ J JL225A 163 C1 1713L B / J JL245A 194 C1 1712L B / J JL1303A 197 K 3420L B / J JL345A 222 C1 1718L B / J JL1306A 259 K 3424L B / J JL1307A 367 K 3428L B J JL1309A 269 K 3428L B J JL1318A 380 K 3520L B / J JL1313A 375 K 3432LC B / J JL1319A 405 K 3528L B J JL1317A 463 K 3528L B J JL1322A 449 K 3532LC B J JL1323A 476 K 3535LC D ALL ABOVE RATINGS CAN BE UL 1081 COMPLIANT THROUGH MOD EXPRESS. SEE THE MOD EXPRESS PROGRAM SECTION IN THIS CATALOG FOR MORE DETAILS. NOTE: All threaded shaft single phase motors are connected single rotation - CCW when viewing drive end. 60 Hz: B= 115/230, B1= 115/230 volts usable at 208 volts, C= 230, D1 = 230 volts, usable at 208 volts, 60 Hz. See notes on pages 8 and 9, and inside back flap. Type C Dimension Volt Code Amps S.F. General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Explosion Proof Pump Commercial 77

78 General Information Single Phase General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Single Phase - Jet Pump - TEFC and ODP continued 60 Hz. Pump ALL ABOVE RATINGS CAN BE UL 1081 COMPLIANT THROUGH MOD EXPRESS. SEE THE MOD EXPRESS PROGRAM SECTION IN THIS CATALOG FOR MORE DETAILS. NOTE: All threaded shaft single phase motors are connected single rotation - CCW when viewing drive end. 60 Hz: B= 115/230, B1= 115/230 volts usable at 208 volts, D1 = 230 volts usable at 208 volts. See notes on pages 8 and 9, and inside back flap. Three Phase - Jet Pump - TEFC Type C Dimension 1/2 thru 3 56J Volt Code Amps Keyed Shaft 56C less Base 1/ C VL1303A 206 K 3420L B / C VL1306A 270 K 3424L B / C VL1307A 350 K 3520L B C VL1309A 292 K 3428L B C VL1318A 400 K 3528L B / C VL1313A 384 K 3432LC B C VL1317A 495 K 3528L B C VL1323A 503 K 3535LC D Stainless Steel Threaded shaft 56J with Base 1/ J CJL1205A 199 K 3416L B / J CJL1301A 300 K 3414L B / J CJL1303A 207 K 3420L B / J CJL1304A 339 K 3418L B / J CJL1306A 264 K 3424L B / J CJL1307A 390 K 3520L B J CJL1309A 271 K 3428L B / J CJL1313A 377 K 3432LC B J CJL1317A 505 K 3528L B Applications: Residential and industrial pumps, swimming pool pumps, etc. Features: Diecast aluminum end plates with machined steel bearing seat insert. S.F. Washdown Duty Explosion Proof Pump Commercial 60 Hz. 1/ J JM K 3410M E / J JM K 3413M E / J JM K 3413M E / J JM K 3416M E / J JM K 3416M E / J JM K 3420M E J JM K 3420M E J JM K 3426M E / J JM K 3516M E / J JM K 3520M E J JM K 3524M E J JM K 3528M E J JM K 3528M E J C-Face with Base 1/ J CJM K 3416M E / J CJM K 3420M E NOTE: 60 Hz: E1 = 230/260 volts usable at 208 volts, E = /460 volts. See notes on pages 8 and 9, and inside back flap. Type C Dimension Volt Code Amps S.F. 78

79 Pump Three Phase - Jet Pump - ODP 1/2 thru 3 56J General Information Applications: Residential and industrial pumps, swimming pool pumps, etc. Features: Diecast aluminum end plates with machined steel bearing seat insert. Single Phase Stainless Steel Threaded Shaft 56J less Base 1/ J JM K 3410M E / J JM K 3413M E / J JM K 3413M E / J JM K 3416M E / J JM K 3416M E / J JM K 3420M E J JM K 3420M E J JM K 3424M E / J JM K 3424M E / J JM K 3520M E J JM K 3430M E J JM K 3524M E J JM K 3524M E J JM K 3535M E Stainless Steel Threaded Shaft 56J with Base 1/ J CJM K 3410M E / J CJM K 3413M E / J CJM K 3413M E / J CJM K 3416M E / J CJM K 3416M E / J CJM K 3420M E J CJM K 3420M E / J CJM K 3424M E J CJM K 3430M E J CJM K 3524M E ALL ABOVE RATINGS CAN BE UL 1081 COMPLIANT THROUGH MOD EXPRESS. SEE MOD EXPRESS PROGRAM SECTION IN THIS CATALOG FOR MORE DETAILS NOTE: All threaded shaft single phase motors are connected single rotation - CCW when viewing drive end. 60 Hz: E = /460 volts, E1= 230/460 usable at 208 volts. See notes on pages 8 and 9, and inside back flap. Three Phase - Continuous Duty - SAE Hydraulic Pump 60 Hz. 60 Hz. Type C Dimension Volt Code Amps 1 thru 10 56YZ thru 215TYZ Applications: Hydraulic pumps for lifts, trash compactors and other machinery Features: TEFC motors designed for continuous duty (may be used on intermittent duty applications). Base mount with SAE A or B pump mount face and shaft. F3 top-mounted conduit box. Type C Dimension YZ HPM K 3516M E 1 1/ TYZ HPM3550T 435 L1 3520M E TYZ HPM3555T 470 L1 3526M E TYZ HPM3611T 496 L1 3546M E TYZ HPM3615T 548 L1 3634M E 7 1/ TYZ HPM3710T 705 L1 3730M E TYZ HPM3714T 832 L1 3740M E Red catalog number = New item S.F. Volt Code General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Explosion Proof Pump Commercial 79

80 General Information Explosion-Proof Jet Pump 1/2 thru 2 56J Pump Applications: Pumping applications that require a hazardous location motor. Single Phase Features: Explosion proof per UL and CSA, Class I, Group D and Class II, Group F & G. UL approved conduit box mounted on motor. Epoxy paint. General Purpose Premium Efficient Super-E C-Face Industrial 60 Hz. NOTE: 60 Hz: A = 115/ , B = 115/230, E = /460, F = 230/460. See notes on pages 8 and 9, and inside back flap. 7 = Class I, Group D, Class II, Group F & G, T4. 8 = Class I, Group D, Class II, Group F & G, T3C. Type C Dimension Volt Code Amps Single Phase less Base 1/ J JL5003A K X3513L B / J JL5006A K X3516L B J JL5009A K X3524L B / J JL K X3528L A J JL K X3535L A Three Phase less Base J JM K X3416M F / J JM K X3516M E J JM K X3524M E S.F. Severe Duty Washdown Duty Square Flange Pump - ODP 1/2 thru 2 56Y Applications: Pump applications where square flange mounting plate is required, such as swimming pools. Features: Ball bearings, stainless steel shaft extension, long life windings. Explosion Proof Pump Commercial 60 Hz. Type NOTE: 60 Hz: B= 115/230, E1=230/460 usable at 208 volts, E = /460 volts. See notes on pages 8 and 9, and inside back flap. C Dimension Volt Code Amps Single Phase 1/ Y JSL1303A 202 K 3416L B / Y JSL1306A 263 K 3424L B Y JSL1309A 275 K 3428L B / YZ JSL1313A 380 K 3432LC B YZ JSL1317A 468 K 3528L B Three Phase 1/ YZ JSM K 3413M E / YZ JSM K 3416M E YZ JSM K 3420M E / YZ JSM K 3424M E YZ JSM K 3430M E S.F. 80

81 Single Phase - Close-Coupled Pump - TEFC and ODP Pump 3 thru thru 215 (JM, JP, TCZ) Applications: Pumping systems where only single phase power is available. Features: Heavy gauge steel frame construction, corrosion resistant finish, ball bearings, suitable for mounting in any position. General Information Single Phase 60 Hz. TEFC, Mechanical Seal - Type JM JM JML3606T 674 L1 3634L B JM JML3608T 899 L1 3640LC C ODP, Mechanical Seal - Type JM JM JML1406T 643 L1 3628L A JM JML1408T 738 L1 3634LC B JM JML1409T 909 L1 3634LC D JM JML1508T 1047 L1 3735L D / JM JML1509T 1305 L1 3729L D / JM JML1510T 1380 L1 3744LC D JM JML1511T 1605 L1 3740L D JM JML1512T 1708 L1 3744LC D ODP, Packed Pump - Type JP JP JPL1406T 643 L1 3628L B JP JPL1408T 738 L1 3634LC B JP JPL1409T 909 L1 3634L D JP JPL1508T 1047 L1 3735L D / JP JPL1509T 1305 L1 3729L D / JP JPL1510T 1380 L1 3744LC D JP JPL1511T 1605 L1 3740L D JP JPL1512T 1708 L1 3744LC D ODP, West Coast Fit TCZ WCL1406T 647 L1 3628L B TCZ WCL1408T 743 L1 3634LC B TCZ WCL1409T 916 L1 3634L D TCZ WCL1508T 1057 L1 3735L D / TCZ WCL1509T 1314 L1 3729L D TCZ WCL1511T 1619 L1 3740L D NOTE: 60 Hz: A = 115/ , B1= 115/230 usable at 208 volts, C = 230, D1= 230 usable at 208 volts. See notes on pages 8 and 9, and inside back flap. Type C Dimension Volt Code Amps S.F. General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Explosion Proof Commercial Pump 81

82 General Information Single Phase General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Three Phase - Washdown Close-Coupled Pump, TENV and TEFC 60 Hz. Pump 1 thru JM thru 215JM Applications: Commercial and industrial water pumps, food processing and applications that expose the motor to high pressure washdown. Features: Over-sized ball bearings with locked drive end construction for minimum shaft movement. Moisture sealant on bolt heads, between frame and endplates. Neoprene gaskets, Forsheda running contact v-ring. Stainless steel shaft. Electrostatic epoxy coating. Tropicalized JM JMWDM3546T 575 L1 3524M E / JM JMWDM3550T 602 L1 3516M F / JM JMWDM3554T 602 L1 3535M E JM JMWDM3555T 670 L1 3524M E JM JMWDM3558T 629 L1 3528M E JM JMWDM3559T 754 L1 3528M E JM JMWDM3611T 754 L1 3535M E JM JMWDM3613T 967 L1 3628M E JM JMWDM3615T 843 L1 3634M E / JM JMWDM3616T 1095 L1 3640M E / JM JMWDM3710T 1079 L1 3729M E JM JMWDM3711T 1472 L1 3735M E JM JMWDM3714T 1363 L1 3740M E JM JMWDM3713T 1755 L1 3744M F NOTE: 60 Hz: E = /460 volts, F = 230/460 volts. See notes on pages 8 and 9, and inside back flap. Three Phase - Close-Coupled Pump - TEFC and ODP Type C Dimension Volt Code Amps 1 thru JM thru 326JP Applications: Applications for circulating and transferring fluids. Mounting designed to support pump unit. Features: Over-sized ball bearings with locked drive end construction to minimize endplay. Open drip-proof, close coupled pump motors are furnished with rodent screens at both ends. EJMM Super-E motors have Premium efficiency. S.F. Explosion Proof Pump Commercial Hz. Totally Enclosed Fan Cooled C-Face with Base JM EJMM3546T 520 L1 3524M E JM JMM3546T 396 L1 3516M E / JM EJMM3550T 516 L1 3524M E / JM JMM3550T 415 L1 3516M E / JM EJMM3554T 553 L1 3528M F / JM JMM3554T 415 L1 3520M E / JP JPM3554T 415 L1 3520M E JM EJMM3555T 554 L1 3532M E JM JMM3555T 463 L1 3524M E JP JPM3555T 473 L1 3524M E JM EJMM3558T 565 L1 3532M E JM JMM3558T 434 L1 3528M E JP JPM3558T 434 L1 3528M E NOTE: 60 Hz: E = /460 volts, F = 230/460 volts. See notes on pages 8 and 9, and inside back flap. Type C Dimension Volt Code Amps S.F.

83 Three Phase - Close-Coupled Pump - TEFC and ODP continued 60 Hz. NOTE: 60 Hz: E = /460 volts, E1=230/460 usable at 208 volts. See notes on pages 8 and 9, and inside back flap. Type C Dimension Pump Volt Code Amps Totally Enclosed Fan Cooled C-Face with Base JM EJMM3559T 595 L1 3540M E JM JMM3559T 520 L1 3528M E JP JPM3559T 520 L1 3528M E JM EJMM3610T 596 L1 3540M E JM JMM3610T 540 L1 3528M E JP JPM3610T 540 L1 3528M E JM EJMM3611T 656 L1 3628M E JM JMM3611T 520 L1 3535M E JP JPM3611T 519 L1 3535M E JM EJMM3613T 707 L1 3634M E JM JMM3613T 666 L1 3628M E JP JPM3613T 666 L1 3628M E JM EJMM3615T 658 L1 3643M E JM JMM3615T 581 L1 3634M E JP JPM3615T 581 L1 3634M E / JM JMM3616T 754 L1 3640M E / JP JPM3616T 754 L1 3640M E / JM EJMM3709T 927 L1 3733M E / JM JMM3709T 849 L1 3723M E / JP JPM3709T 849 L1 3723M E / TCZ WCM3709T 829 L1 3723M E / JM EJMM3710T 1002 L1 3744M E / JM JMM3710T 744 L1 3729M E / JP JPM3710T 761 L1 3729M E / TCZ WCM3710T 744 L1 3729M E JM EJMM3711T 1065 L1 3744M E JM JMM3711T 1015 L1 3735M E JP JPM3711T 1015 L1 3735M E TCZ WCM3711T 992 L1 3735M E JM EJMM3714T 1179 L1 3750M E JM JMM3714T 940 L1 3740M E JP JPM3714T 940 L1 3740M E TCZ WCM3714T 919 L1 3740M E JM JMM3713T 1210 L1 3744M E JP JPM3713T 1210 L1 3744M E TCZ WCM3713T 1184 L1 3744M E JM EJMM2394T 1947 L1 0934M E JM JMM2394T 1761 L1 0744M E JP JPM2394T 1761 L1 0744M E JM EJMM2333T 1930 L1 0936M E JM JMM2333T 1717 L1 0744M E JP JPM2333T 1717 L1 0744M E JM EJMM4106T 2144 L1 0940M E JM JMM4106T 1939 L1 0750M E JP JPM4106T 1939 L1 0750M E JM EJMM2334T 2178 L1 0952M E JM JMM2334T 1818 L1 0938M E JP JPM2334T 1818 L1 0938M E JM EJMM4107T 2492 L1 1038M E JM JMM4107T 2178 L1 0940M E JP JPM4107T 2178 L1 0940M E JM EJMM4103T 2581 L1 1046M E JM JMM4103T 2126 L1 1034M E JP JPM4103T 2126 L1 1034M E S.F. SHADED RATINGS ARE CAST IRON FRAMES General Information Single Phase General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Explosion Proof Pump Commercial 83

84 General Information Single Phase General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Explosion Proof Pump Commercial 84 Three Phase - Close-Coupled Pump - TEFC and ODP continued 60 Hz. Type NOTE: 60Hz: E = /460 volts, E1=230/460 usable at 208 volts, F = 230/460 volts. See notes on pages 8 and 9, and inside back flap. C Dimension Pump Volt Code Amps Totally Enclosed Fan Cooled C-Face with Base continued JM EJMM4108T 3428 L1 1042M E JM JMM4108T 2850 L1 0954M E JP JPM4108T 2850 L1 0954M E JM EJMM4104T 3059 L1 1060M E JM JMM4104T 2506 L1 1040M E JP JPM4104T 2506 L1 1040M E JM EJMM4109T 3617 L1 1240M E JM JMM4109T 3156 L1 1234M E JP JPM4109T 3156 L1 1234M E JM EJMM4110T 3977 L1 1260M E JM JMM4110T 3299 L1 1240M E JP JPM4110T 3299 L1 1240M E JM EJMM4114T 4698 L1 1252M E JM JMM4114T 3733 L1 1064M E JP JPM4114T 3733 L1 1064M E JM EJMM4115T 4781 L1 1266M E JM JMM4115T 3867 L1 1246M E JP JPM4115T 3867 L1 1246M E Totally Enclosed Fan Cooled C-Face less Base JM VEJMM3546T 434 L1 3524M E JM VJMM3546T 402 L1 3516M E / JM VEJMM3554T 458 L1 3528M E / JM VJMM3554T 422 L1 3520M E JM VEJMM3558T 549 L1 3535M E JM VJMM3558T 442 L1 3528M E JM VEJMM3611T 626 L1 3628M E JM VJMM3611T 528 L1 3535M E JM VEJMM3615T 722 L1 3640M E JM VJMM3615T 592 L1 3634M E / JM VEJMM3710T 1059 L1 3735M F / JM VJMM3710T 769 L1 3735M E JM VEJMM3714T 1226 L1 3750M E JM VJMM3714T 950 L1 3740M E JM VJMM2333T 1733 L1 0744M E JM VJMM2334T 1791 L1 0948M E Open Drip Proof C-Face with Base JM EJMM3116T 444 L1 3520M E JM JMM3116T 326 L1 3516M E JP JPM3116T 326 L1 3516M E / JM JMM3120T 381 L1 3516M E / JM EJMM3154T 480 L1 3526M E / JM JMM3154T 361 L1 3520M E / JP JPM3154T 361 L1 3520M E JM EJMM3155T 531 L1 3524M E JM JMM3155T 421 L1 3516M E JM EJMM3157T 526 L1 3532M E JM JMM3157T 375 L1 3524M E JP JPM3157T 375 L1 3524M E JM EJMM3158T 597 L1 3535M E JM JMM3158T 447 L1 3524M E JP JPM3158T 447 L1 3524M E JM EJMM3211T 582 L1 3628M E JM JMM3211T 443 L1 3535M E JP JPM3211T 443 L1 3535M E S.F. SHADED RATINGS ARE CAST IRON FRAMES

85 Three Phase - Close-Coupled Pump - TEFC and ODP continued 60 Hz. Type NOTE: 60Hz: E = /460 volts, E1=230/460 usable at 208 volts, F = 230/460 volts. See notes on pages 8 and 9, and inside back flap. C Dimension Pump Volt Code Amps Open Drip Proof C-Face with Base continued JM EJMM3212T 712 L1 3634M E JM JMM3212T 503 L1 3535M E JP JPM3212T 503 L1 3535M E TCZ WCM3212T 493 L1 3623M E JM EJMM3218T 658 L1 3632M E JM JMM3218T 472 L1 3625M E JP JPM3218T 472 L1 3625M E / JM EJMM3219T 842 L1 3646M E / JM JMM3219T 615 L1 3628M E / JP JPM3219T 615 L1 3628M E / TCZ WCM3219T 600 L1 3628M E / JM EJMM3311T 988 L1 3732M E / JM JMM3311T 697 L1 3726M E / JP JPM3311T 697 L1 3726M E JM EJMM3312T 1085 L1 3736M E JM JMM3312T 790 L1 3720M E JP JPM3312T 790 L1 3720M E TCZ WCM3312T 771 L1 3720M E JM EJMM3313T 1069 L1 3744M F JM JMM3313T 796 L1 3729M E JP JPM3313T 796 L1 3729M E JM EJMM3314T 1351 L1 3744M E JM JMM3314T 979 L1 3729M E JP JPM3314T 979 L1 3729M E TCZ WCM3314T 957 L1 3729M E JM EJMM2513T 1582 L1 3938M E JM JMM2513T 1149 L1 3744M E JP JPM2513T 1175 L1 3744M E JM EJMM2514T 1669 L1 3932M E JM JMM2514T 1232 L1 3930M E JP JPM2514T 1232 L1 3930M E JM EJMM2515T 1895 L1 3944M E JM JMM2515T 1501 L1 3930M E JP JPM2515T 1468 L1 3930M E JM EJMM2516T 2085 L1 3940M E JM JMM2516T 1545 L1 3928M E JP JPM2516T 1545 L1 3928M E JM JMM2531T 1859 L1 3938M E JP JPM2531T 1859 L1 3938M E JM EJMM2534T 2651 L1 4040M F JM JMM2534T 1889 L1 3936M E JP JPM2534T 1889 L1 3936M E JM JMM2535T 2132 L1 3952M E JP JPM2535T 2132 L1 3952M E JM EJMM2538T 2957 L1 4054M F JM JMM2538T 2228 L1 3946M E JP JPM2538T 2228 L1 3946M E JM JMM2539T 2766 L1 4040M E JP JPM2539T 2766 L1 4040M E JM EJMM2542T 3599 L1 4058M F JM JMM2542T 2785 L1 4040M F JP JPM2542T 2785 L1 4040M F JM JMM2543T 2997 L1 4058M E JP JPM2543T 2997 L1 4058M E S.F. General Information Single Phase General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Explosion Proof Pump Commercial 85

86 General Information Single Phase General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Explosion Proof Pump Commercial 86 Three Phase - Close-Coupled Pump - TEFC and ODP continued NOTE: 60 Hz: E = /460 volts, E1 = 230/460 volts usable at 208 volts, F = 230/460 volts. See notes on pages 8 and 9, and inside back flap. Three Phase - Close-Coupled Pump - Explosion Proof 60 Hz. 60 Hz. NOTE: 60 Hz: E = /460, F = 230/460. See notes on pages 8 and 9, and inside back flap. 1 = Class I, Group D, T2C. Pump 3 thru JM thru 215JM Applications: Applications for circulating and transferring fluids in hazardous locations. Features: C-face with base. Corrosion resistant epoxy finish, rotors corrosion treated and precision balanced to insure smooth operation Service Factor. CAUTION: Explosion-proof motors have a tight fit between mating parts to ensure the integrity of the explosion-proof enclosure. This can lead to an accumulation of moisture inside the motors due to condensation. Care should be used when selecting an explosion-proof motor, especially when installed outdoors and on intermittent duty. These explosion-proof motors are not suitable for use with adjustable speed drives, inverter duty explosion-proof motors must be used. See page 163. See notes on pages 4 and 8. Type C Dimension Volt Code Amps JM JMM7075T L1 X3528M E JM JMM7026T L1 X3620M E JM JMM7072T L1 X3628M F / JM JMM7073T L1 X3640M F / JM JMM7045T L1 X3729M F JM JMM7074T L1 X3740M F Type C Dimension Volt Code Amps Open Drip Proof C-Face with Base continued JM JMM2546T 3218 L1 4054M F JP JPM2547T 3575 L1 4252M E TCZ JPM2555T 5321 D3 4462M E TCZ JPM2559T 6271 D3 4476M F Open Drip Proof C-Face less Base JM VEJMM3116T 444 L1 3524M E JM VJMM3116T 333 L1 3516M E / JM VEJMM3154T 458 L1 3530M E / JM VJMM3154T 366 L1 3520M E JM VEJMM3157T 461 L1 3532M E JM VJMM3157T 382 L1 3524M E JM VJMM3158T 455 L1 3524M E JM VEJMM3211T 590 L1 3628M E JM VJMM3211T 447 L1 3535M E JM VJMM3212T 509 L1 3535M E JM VEJMM3218T 662 L1 3632M E JM VJMM3218T 478 L1 3625M E / JM VJMM3219T 621 L1 3634M E / JM VEJMM3311T 996 L1 3744M E / JM VJMM3311T 700 L1 3726M E JM VJMM3312T 779 L1 3720M E JM VEJMM3313T 1078 L1 3750M E JM VJMM3313T 803 L1 3729M E JM VJMM3314T 986 L1 3729M E S.F. S.F.

87 Three Phase - P-Base Vertical Solid Shaft Pump Service Factor TEFC 60 Hz. Pump 3 thru LP thru 365VP Applications: For normal medium and high thrust in-line pump applications. Waste water treatment plants, petro chemical industries, pulp and paper mills and agricultural irrigation applications. Features: Severe duty construction with corrosion resistant epoxy finish, cast iron construction, designed for vertical mounting. Rotatable conduit box, stainless steel nameplates, shaft seals. Energy efficient windings. Two lifting lugs for balanced lifting. VHECP mtoros have Premium efficiency and are Inverter-Ready Service Factor. Super-E Efficiency - Normal Thrust HP VHECP3660T 1508 L1 0628M E HP VHECP3661T 1350 L1 0628M E HP VHECP3663T 1948 L1 0634M F HP VHECP3665T 1798 L1 0643M E / HP VHECP3769T 2307 L1 0733M E / HP VHECP3770T 2232 L1 0740M E HP VHECP3771T 2406 L1 0744M E HP VHECP3774T 2505 L1 0750M E HP VHECP2394T 2773 L1 0934M E HP VHECP2333T 2875 L1 0936M E HP VHECP4106T 3016 L1 0944M E HP VHECP2334T 3265 L1 0952M E HP VHECP4107T 3207 L1 0950M E HP VHECP4103T 3642 L1 1046M E HP VHECP4108T 3532 L1 0954M E HP VHECP4104T 4089 L1 1060M E HP VHECP4109T 4944 L1 1244M E HP VHECP4110T 4624 L1 1260M E HP VHECP4114T 6059 L1 1252M E HP VHECP4115T 6532 L1 1266M E HP VHECP4310T 7742 L1 1458M E HP VHECP4314T 8081 L1 1462M E HP VHECP4313T 9673 L1 1472M F HP VHECP4316T 9842 L1 1482M E Standard Efficiency - Medium Thrust LP VLCP3660T 1495 L1 0620M E LP VLCP3661T 1337 L1 0623M E LP VLCP3663T 1930 L1 0634M E LP VLCP3665T 1782 L1 0634M E / LP VLCP3769T 2286 L1 0723M E / LP VLCP3770T 2212 L1 0735M E LP VLCP3771T 2385 L1 0735M E LP VLCP3774T 2482 L1 0740M E LP VLCP2394T 2747 L1 0744M E LP VLCP2333T 2848 L1 0744M E LP VLCP4106T 3000 L1 0932M E LP VLCP2334T 3233 L1 0938M E LP VLCP4107T 3178 L1 0940M E LP VLCP4103T 3609 L1 1044M E LP VLCP4108T 3498 L1 0954M E LP VLCP4104T 4050 L1 1050M E LP VLCP4109T 4898 L1 1234M E LP VLCP4110T 4581 L1 1248M E Standard Efficiency - High Thrust VP VPCP4114T 6002 L1 1246M E VP VPCP4115T 6471 L1 1246M E VP VPCP4310T 6902 L1 1440M E VP VPCP4314T 7206 L1 1450M E VP VPCP4313T 8623 L1 1448M E VP VPCP4316T 8774 L1 1462M E NOTE: 60Hz: E1=230/460 usable at 208 volts, E = /460 volts SHADED RATINGS ARE CAST IRON FRAMES See notes on pages 8 and 9, and inside back flap. See Bearing notes at bottom of page 88. Type Max Thrust (lbs) Volt Code Amps General Information Single Phase General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Explosion Proof Pump Commercial 87

88 General Information Single Phase General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Three Phase - P-Base Vertical Solid Shaft Pump Service Factor ODP 60 Hz. Pump 3 thru LP thru 365VP 1.15 Service Factor Applications: For normal thrust applications. Waste water treatment plants, petro-chemical, pulp and plants and agricultural irrigation application. Features: Cast iron frame and endplates. EPAct efficiency for energy efficiency over typical P-Base designs. Rotatable conduit box, stainless nameplate, epoxy finish. Two lifting lugs for balanced lifting. Type Max Thrust (lbs) Volt Code Amps EPAct High Efficiency - Normal Thrust HP VHM3210T 1358 L1 0623M E HP VHM3211T 1214 L1 0625M E HP VHM3212T 1753 L1 0623M E HP VHM3218T 1618 L1 0628M E / HP VHM3219T 2076 L1 0630M E / HP VHM3311T 2009 L1 0646M E HP VHM3312T 2167 L1 0725M E HP VHM3313T 2254 L1 0738M E HP VHM3314T 2287 L1 0735M E HP VHM2513T 2371 L1 0932M E HP VHM2514T 2488 L1 0930M E HP VHM2515T 2693 L1 0936M E HP VHM2516T 2647 L1 0934M E HP VHM2531T 3005 L1 1044M E HP VHM2534T 2913 L1 1040M E HP VHM2535T 3374 L1 1046M E HP VHM2538T 4203 L1 1054M E HP VHM2539T 3931 L1 1250M E HP VHM2542T 5151 L1 1254M E HP VHM2543T 5553 L1 1256M E HP VHM2546T 6582 L1 1400M E HP VHM2547T 6870 L1 1400M E HP VHM2549T 8223 L1 1400M F HP VHM2551T 8366 L1 1400M E NOTE: 60Hz: E = /460V, E1=230/460 usable at 208 volts, F = 230/460 volts SHADED RATINGS ARE CAST IRON FRAMES See notes on pages 8 and 9, and inside back flap. VHECP, VHM and VLCP motors are capable of 100% thrust in either direction. VPCP motors are capable of 100% thrust stated in downward direction (out of motor) and 40% upward thrust (into motor). Custom TEFC motors available through 900 ; Open and WPII motors through Contact your Baldor Sales Representative. Explosion Proof (THRUST BEARINGS MUST BE LOADED TO A MINIMUM OF 20% OF RATED THRUST FOR PROPER BEARING LOADING AND LIFE.) Pump Commercial 88

89 Single Phase - Commercial Duty, Jet Pump - ODP 60 Hz. Commercial Duty 1/4 thru 3 56C and 56J Applications: Commercial Pumps, Residential Pumps, Swimming Pool Pumps, etc. Features: 40 C Ambient, 60 Hertz, Aluminum Endplates, Automatic Thermal Overload, Ball Bearings, Capacitor Start, High Service Factors, Terminal Panel with Quick Connections and ground screw, Shaft Slinger C Dimension Stainless Steel Threaded Shaft 56J Less Base - Open Drip Proof 1/ J JL145A 167 C /230* 4.4/ / J JL225A 163 C /230* 5.6/ / J JL245A 194 C /230* 5.4/ / J JL325A 181 C /230* 6.6/ / J JL345A 222 C /230* 7.2/ / J JL425A 206 C /230* 9.2/ / J JL445A 248 C /230* 10.6/ J JL525A 234 C /230* 15.2/ J JL545A 293 C /230* 13.4/ / J JL625A 283 C /230 18/ J JL725A 341 C /230 26/ J JL825A 390 C Keyed Shaft 56C Less Base - Open Drip Proof 1/ C VL145A 161 C /230* 4.4/ / C VL225A 157 C /230* 5.6/ / C VL245A 188 C /230* 5.4/ / C VL325A 177 C /230* 6.6/ / C VL345A 216 C /230* 7.2/ / C VL425A 201 C /230* 9.2/ / C VL445A 241 C /230* 10.6/ C VL525A 226 C /230* 15.2/ C VL545A 277 C /230* 13.4/ / C VL625A 265 C /230 18/ C VL725A 319 C /230 26/ C VL825A 367 C NOTE: Data subject to change without notice. Contact Baldor for certified data. * 60 Hz. 208 volts. Volts Amps S.F. General Information Single Phase General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Explosion Proof Commercial Pump 89

90 General Information Single Phase - Two Compartment Jet Pump - ODP Commercial Duty 1/4 thru 1 56C and 56J Single Phase Applications: Swimming Pool Pumps, Spa and Hot Tub pumps General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty 60 Hz. NOTE: Data subject to change without notice. Contact Baldor for certified data. * 60 Hz. 208 volts. Features: 50 C Ambient, 60 Hertz, Aluminum Endplates, Automatic Thermal Overload, Ball Bearings, Capacitor Start, High Service Factors, Terminal Panel with Quick Connections and Ground Screw, Shaft Slinger, easier maintenance. C Dimension Volts Amps Stainless Steel Threaded Shaft 56J Less Base - Open Drip Proof 1/ J J2L145A 177 C /230* 4.4/ / J J2L225A 171 C /230* 5.6/ / J J2L325A 191 C /230* 6.6/ / J J2L345A 234 C /230* 7.2/ / J J2L425A 217 C /230* 9.2/ / J J2L445A 261 C /230* 10.6/ J J2L525A 245 C /230* 15.2/ Stainless Steel Threaded Shaft 56J With Base - Open Drip Proof 1/ C V2L145A 170 C /230* 4.4/ / C V2L225A 165 C /230* 5.6/ / C V2L245A 198 C /230* 5.4/ / C V2L325A 186 C /230* 6.6/ / C V2L345A 226 C /230* 7.2/ / C V2L425A 212 C /230* 9.2/ / C V2L445A 254 C /230* 10.6/ C V2L525A 238 C /230* 15.2/ S.F. Explosion Proof Pump Commercial 90

91 Single Phase - Commercial Square Flange Pump - ODP Commercial Duty 1/3 thru 2 56YZ General Information Applications: Commercial Pumps, Residential Pumps, Swimming Pool Pumps, etc. Single Phase Features: 40 C Ambient, 60 Hertz, Aluminum Endplates, Ball Bearings, Capacitor Start (Single Phase only), Stainless Steel Shaft Extension, Terminal Panel with Quick Connections (Single Phase only), Automatic Thermal Overload (Single Phase only), Ground Screw in Lead End Endplate, Shaft Slinger General Purpose 60 Hz. C Dimension Volts Amps Single Phase - Open Drip Proof 1/ Y JSL225A 179 C /230* 5.6/ / Y JSL325A 195 C /230* 6.6/ / Y JSL425A 221 C /230* 9.2/ Y JSL525A 236 C /230* 15.2/ / YZ JSL625A 292 C /230 18/ YZ JSL725A 350 C /230 26/ S.F. Premium Efficient Super-E C-Face Industrial NOTE: Data subject to change without notice. Contact Baldor for certified data. * 60 Hz. 208 volts. Commercial Pump Explosion Proof Washdown Duty Severe Duty 91

92 General Information Single Phase Single Phase - Commercial Duty, General Purpose - ODP, Resilient Base Commercial Duty 1/4 thru 2 48 and 56H Applications: Ventilators, Summer cooling fans, band saws, drill presses, farm equipment. General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty 60 Hz. NOTE: Data subject to change without notice. Contact Baldor for certified data. * 60 Hz. 208 volts. Features: Automatic Thermal Overload, Ball Bearings, Resilient Cushion Rings, Reversible Rotation, Rugged Steel Base, Terminal Panel with Quick Connections C Dimension Volts Amps 1/ RL144A 180 C /230* 4.4/ / RL224A 161 C /230* 5.4/ / RL245A 193 C /230* 5.4/ / RL324A 175 C /230* 7/ / RL325A 177 C /230* 7/ / RL344A 221 C /230* 7.2/ / RL345A 223 C /230* 7.2/ / RL425A 209 C /230* 9.4/ / RL445A 237 C /230* 10.6/ RL525A 249 C /230* 11.8/ RL545A 299 C /230* 13/ / /56H RL625A 288 C /230* 18/ / /56H RL645A 358 C /230* 18.2/ /56H RL725A 341 C /230* 26/ S.F. Explosion Proof Pump Commercial 92

93 Single and Three Phase - Commercial Duty, Heating, Ventilating and Air Conditioning Blower - OPAO, Resilient Base Commercial Duty 1/4 thru 2 48 and 56H Applications: Fans for Heating, Ventilation and Air Conditioning Blowers, Designed for Continuous Air-Over Applications with Moderate Starting s General Information Single Phase Features: Automatic Thermal Overload, Ball Bearings, Resilient Cushion Rings, Reversible Rotation, Rugged Steel Base, Terminal Panel with Quick Connections (Single Phase only) General Purpose 60 Hz. NOTE: Data subject to change without notice. Contact Baldor for certified data. * 60 Hz. 208 volts. C Dimension Volts Amps Single Phase - Permanent Split Capacitor - Open Air-Over 1/ RHC144A 175 C /230* 3/ / RHC164A 200 C /230* 3.4/ / RHC244A 180 C /230* 3.6/ / RHC264A 204 C /230* 3.8/ / RHC344A 215 C /230* 6/ / RHC345A 217 C /230* 6/ / RHC364A 241 C /230* 6/ / RHC365A 246 C /230* 6/ / RHC445A 230 C /230* 8/ / RHC465A 271 C /230* 8.8/ RHC545A 260 C /230* 10.2/ RHC565A 310 C / / / RHC645A 299 C / / / RHC665A 356 C /230 16/ RHC745A 348 C /230 19/ Three Phase - Open Air-Over 1/ RHM144A 169 C /460* 1.1/ / RHM164A 194 C /460* 1.3/ / RHM244A 175 C /460* 1.5/ / RHM265A 199 C /460* 1.7/ / RHM344A 207 C /460* 2.3/ / RHM345A 211 C /460* 2.3/ / RHM364A 234 C /460* 2.2/ / RHM365A 236 C /460* 2.2/ / RHM445A 222 C /460* 3.4/ / RHM465A 268 C /460* 3.4/ RHM545A 259 C /460* 3.8/ H RHM565A 313 C /460* / / H RHM645A 304 C /460* 5-4.8/ / H RHM665A 346 C /460* / H RHM745A 338 C /460* / S.F. Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Explosion Proof Pump Commercial 93

94 General Information Single Phase Single and Three Phase - Commercial Duty, Direct Drive Fan - TEAO, Resilient Base Commercial Duty 1/4 thru 1-1/2 48Z, 56 thru 56Z Applications: Air Handling Fans, Confinement Houses, Exhaust Fans, Unit Heaters, Designed for Continuous Air-Over Applications with Moderate Starting s General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Explosion Proof Pump Commercial 60 Hz. NOTE: Data subject to change without notice. Contact Baldor for certified data. * 60 Hz. 208 volts. Features: Automatic Thermal Overload, Ball Bearings, Extended Thru-Bolts, Resilient Cushion Rings, Reversible Rotation, Rugged Steel, Suitable for Mounting in any Position, Terminal Panel with Quick Connections (Single Phase only) C Dimension Volts Amps Single Phase - Permanent Split Capacitor - Totally Enclosed Air-Over 1/ Z CHC144A 184 C /230* 3/ / Z CHC164A 209 C /230* 3.2/ / Z CHC244A 193 C /230* 4.2/ / Z CHC264A 217 C /230* 4/ / Z CHC344A 226 C /230* 5.8/ / Z CHC345A 228 C /230* 5.8/ / Z CHC364A 253 C /230* 6.4/ / Z CHC365A 256 C /230* 6.4/ / Z CHC445A 244 C / / / CHC465A 295 C /230 9/ CHC545A 288 C / / CHC565A 342 C / / / CHC645A 329 C / / Three Phase - Totally Enclosed Air-Over 1/ Z CHM144A 178 C /460* 1/ / Z CHM164A 216 C /460* 1.3/ / Z CHM244A 187 C /460* 1.3/ / Z CHM264A 211 C /460* 1.7/ / Z CHM344A 221 C /460* 1.9/ / Z CHM345A 223 C /460* 1.9/ / Z CHM364A 246 C /460* 2.2/ / Z CHM365A 248 C /460* 2.2/ / Z CHM445A 236 C /460* 2.8/ / Z CHM465A 285 C /460* 3.6/ Z CHM545A 280 C /460* / CHM565A 331 C /460* / / CHM645A 320 C /460* 5.3-5/ S.F. 94

95 Split Phase - Commercial Duty, Fan and Blower - ODP, Resilient Base Commercial Duty 1/4 thru 1/2 48 and 56 Applications: Air Conditioning Equipment, Blowers, Fans, Designed for Applications with Moderate Starting s General Information Single Phase 60 Hz. NOTE: Data subject to change without notice. Contact Baldor for certified data. Incubator/Hatchery, Commercial Duty, Vent Fan - TEAO Features: 1.25 Service Factor, Automatic Thermal Overload, Ball Bearings, Reversible Rotation, Rugged Steel Base, Terminal Panel with Quick Connections, Base Notched with Mounting Holes for 48 and 56 NOTE: Data subject to change without notice. Contact Baldor for certified data. C Dimension 1/4 thru 1/2 48YZ Applications: Direct Drive Hatchery and Incubator Fan Volts Amps 1/ RSP1441A 157 C / RSP1442A 160 C / RSP2452A 175 C / RSP2451A 170 C / RSP2442A 171 C / RSP2441A 167 C / RSP3442A 200 C / RSP3441A 195 C / RSP3451A 198 C / RSP3452A 202 C Hz. Features: 1.0 Service Factor, 40 C Ambient, 60 Hertz, Automatic Thermal Overload, Ball Bearings, Class B Insulation, Extended Thru-Bolts, Terminal Panel with Quick Connections, Permanent Split Capacitor, Shaft Slinger, 1625 or 1725 Available, Pilot Circuit C Dimension Permanent Split Capacitor - Totally Enclosed Air-Over Volts Amps 1/ Z HIC164A 223 C / / / Z HIC264A 240 C / / / Z HIC364A 259 C / / Permanent Split Capacitor - Totally Enclosed Air-Over 1/ Z HIC174A 223 C /230 3/ / Z HIC274A 240 C / / / Z HIC374A 259 C /230 5/ S.F. S.F. General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Explosion Proof Pump Commercial 95

96 General Information Single Phase General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Single Phase - Commercial Duty, Condenser Fan - TEAO, Round Body 60 Hz. Commercial Duty 1/4 THRU 1/2 HP 48YZ Applications: C Dimension Totally Enclosed Air-Over - Permanent Split Capacitor - All Angle Volts Amps 1/ YZ CFC1641A 162 C / YZ CFC2614A 173 C * / YZ CFC2642A 178 C * / YZ CFC3614A 192 C * / YZ CFC3642A 195 C * Totally Enclosed Air-Over - Permanent Split Capacitor - Shaft Up Only - Closed Except Lead End 1/ YZ CFC1614A 157 C * / YZ CFC1624A 157 C / YZ CFC1642A 162 C * / YZ CFC2624A 180 C / YZ CFC2641A 178 C / YZ CFC3624A 201 C / YZ CFC3641A 195 C NOTE: Data subject to change without notice. Contact Baldor for certified data. * 60 Hz. 208 volts. Condenser Fans, Heat Pump, Refrigeration, Designed for Continuous Air-Over Applications Features: 6 Long x 1/2 Diameter Shaft with 2 Flats 90 Apart, 30 Inch Leads, 60 C Ambient, 60 Hertz, Automatic Thermal Overload, Sealed Ball Bearings, Class B Insulation, 370 Volt Capacitor (not included), Extended Thru-Bolts, Permanent Split Capacitor, Reversible Rotation, Shaft Slinger, 1.0 Service Factor S.F. Explosion Proof Pump Commercial 96

97 Single Phase - Commercial Duty, Direct Drive, Indoor Blower - ODP, Round Body 60 Hz. Commercial Duty 1/4 thru 1/2 48YZ Applications: Air Handling, Evaporators, Furnace Blowers, Designed for Continuous Air- Over Applications Features: 6 Long x 1/2 Diameter Shaft with 2 Flats 90 Apart, 30 Inch Leads, 40 C Ambient, 60 Hertz, Automatic Thermal Overload, Ball Bearings, Class B Insulation, 370 Volt Capacitor (not included), Extended Thru- Bolts, Permanent Split Capacitor, Reversible Rotation, 1.0 Service Factor C Dimension Open Air-Over - Permanent Split Capacitor Volts Amps 1/ YZ DDC1641A 150 C / YZ DDC1642A 150 C / YZ DDC2442A 144 C / YZ DDC2641A 170 C / YZ DDC2642A 170 C / YZ DDC3641A 187 C / YZ DDC3642A 187 C S.F. General Information Single Phase General Purpose Premium Efficient Super-E C-Face Industrial NOTE: Data subject to change without notice. Contact Baldor for certified data. Commercial Pump Explosion Proof Washdown Duty Severe Duty 97

98 General Information Single Phase Single Phase - Commercial Duty, Yoke/Pedestal Fan - TEAO Commercial Duty 1/4 thru 1/2 48YZ thru 56YZ Applications: Air Circulation, Designed for Continuous Air-Over Applications General Purpose Premium Efficient Super-E C-Face Industrial Severe Duty Washdown Duty Explosion Proof 60 Hz. NOTE: Data subject to change without notice. Contact Baldor for certified data. C * C Dimension Drawing * See chart above for C dimension. Features: 1.0 Service Factor, 40 C Ambient, Automatic Thermal Overload, Ball Bearings, Class B Insulation, Extended Thru-Bolts on 5.13 Inch, Bolt Circle For Mounting Fan Shroud, Heavy Gage Steel Yoke with 180 Slot for Wide Angle Rotation, Permanent Split Capacitor, Pull Chain Switch (2spd only) for High and Low Speed, Reversible Rotation, Shaft Slinger, Terminal Panel with Quick Connections C Dimension Volts Amps Permanent Split Capacitor - Totally Enclosed Air-Over 1/ YZ YPC144A 161 C / YZ YPC164A 178 C / YZ YPC245A 173 C / YZ YPC244A 171 C / YZ YPC265A 194 C / YZ YPC264A 192 C / YZ YPC345A 201 C / YZ YPC344A 199 C / YZ YPC365A 228 C / YZ YPC364A 226 C Two Speed - Permanent Split Capacitor - Totally Enclosed Air-Over 1/4 1075/875 48YZ YPC1624A 193 C / /3 1075/875 48YZ YPC2624A 216 C / /3 1075/875 56YZ YPC2625A 218 C / /2 1075/950 56YZ YPC3625A 279 C / /2 1075/950 48YZ YPC3624A 276 C / U (Shaft Shoulder) Dimension Description Flat, 2.25 Long Flat, 2.25 Long S.F. Pump Commercial 98

99 Single and Three Phase - Fan and Blower - ODP, Resilient Base HVAC 1/4 thru 3 48 thru 56H Applications: Ventilators, summer cooling fans, band saws, drill presses, farm equipment. Features: Heavy gauge steel base, ball bearings, suitable for mounting in any position. Dynamically balanced rotors for reduced vibration and quiet operation. HVAC Farm Duty 60 Hz. 1/ RL144A 180 C1 1710L B / RL1205A # 188 K 3413L B / RL1301A # 260 K 3414L B / RL1208A # 206 K 3416L B / RL1303A 220 K 3416L B / RL1304A # 281 K 3418L B / RL1323A # 257 K 3416L B 4.0 3/ RL1306A # 258 K 3420L B / /56H RL1307A 346 K 3428L B / RL1324A # 278 K 3424L B /56H RL1309A 298 K 3520L B /56H RL1310A # 375 K 3520L B / /56H RL1313A 384 K 3524L B / /56H RL1319A # 455 K 3528L B /56H RL1317A # 478 K 3528L B Single Phase 277 Volt 1/ RL1301A K 3414L Y 2.5 1/ RL1304A K 3418L Y 3.6 3/ /56H RL1307A K 3520L Y /56H RL1310A K 3528L Y / /56H RL1319A K 3535L Y 8.5 Three Phase 1/ RM K 3410M E / RM K 3410M E / RM K 3413M E / RM K 3413M E / RM K 3410M E / RM K 3416M E / RM K 3416M E / RM K 3413M E / RM K 3420M E RM K 3416M E RM K 3426M E / H RM K 3424M E / /56H RM K 3520M E H RM K 3428M E /56H RM K 3524M E /56H RM K 3524M E 4.0 NOTE: 60 Hz: B = 115/230, B1= 115/230 volts usable at 208 volts, E= /460 volts, E1=230/460 volts usable at 208 volts, Y = 277 volts. See notes on pages 8 and 9, and inside back flap. Type C Dimension Volt Code Amps Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz Inverter/Vector & Controls Servo DC 99

100 HVAC Farm Duty Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz Inverter/Vector & Controls Servo DC 100 Three Phase - Chiller/Cooling Tower - TEAO 60 Hz. HVAC 5 thru T thru 365T Applications: For use in the airstream on cooling towers. NOTE: 60 Hz: E1=230/460 volts usable at 208 volts, E= /460 volts, F= 230/460 volts. See notes on pages 8 and 9, and inside back flap. Red catalog number = New item Features: 1.15 Service Factor, corrosion resistant epoxy finish, double sealed bearings filled with moisture resistant grease, shaft seal/slinger, Class F insulation, moisture resistant copper windings, double dipped and baked, stainless steel nameplates and corrosion resistant hardware. Designed for wet, high humidity environments. ECTM Super-E motors have Premium efficiency and 3 year warranty. Direct replacement for most OEM applications. Type C Dimension Volt Code Amps Minimum Air Velocity (FPM) T ECTM3665T 780 L1 0643M E T CTM3665T 713 L1 0638M E T ECTM3768T 1239 L1 0744M E T CTM3768T 1083 L1 0735M E / T ECTM3770T 1040 L1 0740M E / T CTM3770T 951 L1 0735M E / T ECTM2276T 1765 L1 0954M E / T CTM2276T 1321 L1 0760M E T ECTM3774T 1168 L1 0750M E T CTM3774T 1214 L1 0740M E T ECTM2332T 2016 L1 0960M E T CTM2332T 1471 L1 0946M E T ECTM2333T 1606 L1 0936M E T CTM2333T 1613 L1 0756M F T ECTM4100T 2689 L1 1054M E T CTM4100T 2346 L1 1036M E T ECTM2334T 1947 L1 0952M E T CTM2334T 1799 L1 0938M E T ECTM4102T 3581 L1 1060M E T CTM4102T 2835 L1 1042M E T ECTM4103T 2547 L1 1046M E T CTM4103T 2181 L1 0956M E T ECTM4111T 4052 L1 1080M F T CTM4111T 3420 L1 1072M E T ECTM4104T 3023 L1 1060M E T CTM4104T 2617 L1 0964M E T ECTM4117T 4682 L1 1260M E T CTM4117T 4149 L1 1080M E T ECTM4110T 3953 L1 1260M E T CTM4110T 3483 L1 1248M E T ECTM4308T 5834 L1 1468M F T CTM4308T 4597 L1 1464M E T ECTM4115T 4008 L1 1266M E T CTM4115T 4111 L1 1080M E T ECTM4312T 7051 L1 1474M E T CTM4312T 5834 L1 1456M E T ECTM4314T 6218 L1 1462M E T CTM4314T 5564 L1 1454M E T ECTM4403T 8387 L1 1672M F T CTM4403T 7218 L1 1484M F T ECTM4316T 7271 L1 1482M E T CTM4316T 6689 L1 1476M E SHADED RATINGS ARE CAST IRON FRAMES

101 Three Phase - ODP, Resilient HVAC 1/2 thru 3 56 thru 182T Applications: Heating, ventilation and air conditioning blower and fan motors. Features: Heavy gauge steel base, ball bearings, automatic thermal overload. Suitable for mounting in any position. Dynamically balanced rotors for reduced vibration and quiet operation. HVAC Farm Duty 60 Hz. Resilient Base 1/ H RM3108A 316 K 3416M E / H RM3111A 318 K 3413M E / H RM3112A 341 K 3420M E H RM3115A 335 K 3416M E /56H RM3116A 355 K 3516M E / H RM3120A 380 K 3424M E / /56H RM3154A 377 K 3520M E /56H RM3155A 439 K 3428M E H RM3157A 432 K 3524M E HZ RM3158TA 435 K 3528M E HZ RM3161TA 472 K 3540M E 4.1 NOTE: 60 Hz: E1=230/460 usable at 208 volts, E = /460 volts. See notes on pages 8 and 9, and inside back flap. Baldor 56H frames will also mount as 56, 143T and 145T frames with 56 frame shaft dimensions. Baldor 56HZ resilient base frames will also mount as 56, 143T and 145T frames with 145T frame shaft dimensions. Type C Dimension Volt Code Amps Definite Purpose Brake 200 & 575 Volt DC Servo Inverter/Vector & Controls 50 Hertz IEC 101

102 HVAC Farm Duty Three Phase - ODP, Resilient and Rigid Base HVAC 1/2 thru 5 56 thru 184T Applications: Ventilators, direct-drive or belted fan and ventilation applications. Features: Heavy gauge steel base, ball bearings, suitable for mounting in any position. Dynamically balanced rotors for reduced vibration and quiet operations. Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz Inverter/Vector & Controls Servo DC 60 Hz. Rigid Base 1/ HM K 3416M E / HM3108A 288 K 3416M E / HM K 3420M E 1.5 3/ HM3112A 317 K 3420M E HZ HM K 3426M E HZ HM3116A 350 K 3424M E / HZ HM K 3520M E / HZ HM3154A 349 K 3520M E HZ HM K 3524M E HZ HM3157A 402 K 3524M E HZ HM3161A 439 K 3535M E T HM3218TA 496 L1 3630M E 7.0 Resilient Base 1/ RHM K 3410M E / RHM K 3413M E / RHM K 3413M E / RHM K 3414M E / RHM K 3416M E / H RHM3108A 299 K 3416M E / RHM K 3416M E / H RHM3111A 301 K 3413M E / RHM K 3424M E / H RHM3112A 322 K 3420M E RHM K 3416M E H RHM3115A 319 K 3416M E RHM K 3426M E H RHM3116A 340 K 3426M E / H RHM3120A 361 K 3424M E / H RHM K 3520M E / H RHM3154A 349 K 3520M E H RHM3155A 418 K 3428M E H RHM K 3524M E H RHM3157A 402 K 3524M E H RHM K 3524M E T RHM3158TA 457 L1 3526M E T RHM3161TA 444 L1 3540M E HZ RHM3162TA 624 K 3535M E 6.5 NOTE: 60 Hz: E1=230/460 usable at 208 volts. E= /460 volts. See notes on pages 8 and 9, and inside back flap. Type C Dimension Volt Code Amps 102

103 Three Phase - HVAC Variable Torque - ODP HVAC 1/2 thru thru 365T Applications: Heating, ventilation and air conditioning fans and blowers HVAC Features: Heavy gauge steel frame construction, ball bearings, 1.15 service factor. Dynamically balanced rotors for reduced vibration and quiet operation. Suitable for mounting in any position. HM models meet EPAct efficiencies. EHM models have higher efficiencies. Farm Duty 60 Hz. F1 Mounting HZ HM LS 3426M E T EHM9210T 345 L1 3518M E / T HM9214T 276 LS 3522M E / T EHM9214T 345 L1 3524M E T HM9218T 300 LS 3526M E T EHM9218T 407 L1 3528M E T HM9222T 325 LS 3540M E T EHM9222T 438 L1 3542M E T HM9226T 358 LS 3628M E T EHM9226T 479 L1 3635M E / T HM9229T 500 LS 3726M E / T EHM9229T 705 L1 3732M E T HM9232T 627 LS 3734M E T EHM9232T 855 L1 3744M E T HM9235T 940 LS 3750M E T EHM9235T 1211 L1 3756M E T HM9239T 1144 LS 3936M E T EHM9239T 1522 L1 3940M F T HM9242T 1388 LS 3942M E T EHM9242T 1855 L1 4040M F T HM9246T 1603 LS 3952M E T EHM9246T 2029 L1 4048M E T HM9249T 2068 LS 4049M E T EHM9249T 2647 L1 4060M E T HM9252T 2397 LS 4057M E T EHM9252T 2922 L1 4066M E T HM9255T 2959 LS 4250M E T EHM9255T 3679 L1 4262M E T HM9258T 3625 LS 4266M E T EHM9258T 4519 L1 4276M E F3 Mounting 1/ H3M LS 3410M E / EH3M K 3410M E / H3M LS 3416M E / EH3M K 3416M E / H3M LS 3416M E / EH3M K 3419M E / H3M LS 3420M E 1.5 3/ EH3M K 3424M E H3M LS 3420M E EH3M K 3423M E HZ H3M LS 3426M E T EH3M9210T 364 L1 3518M E 1.5 NOTE: 60 Hz: E= /460 volts, E1= 230/460 volts, usable at 200 volts, F= 230/460 volts, E2= 230/460 usable at 200 volts. See notes on pages 8 and 9, and inside back flap. Type C Dimension Volt Code Amps Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz Inverter/Vector & Controls Servo DC 103

104 HVAC Farm Duty Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz Inverter/Vector & Controls Servo DC Three Phase HVAC - Variable Torque - ODP continued 60 Hz. NOTE: 60 Hz: E= /460 volts, E1= 230/460 volt, usable at 208 volts, E2= 230/460 usable at 200 volts. See notes on pages 8 and 9, and inside back flap. Type C Dimension HVAC F3 Mounting continued 1 1/ T H3M9212T 303 LS 3518M E / T EH3M9212T 356 L1 3518M E / T H3M9214T 276 LS 3522M E / T EH3M9214T 379 L1 3524M E T H3M9217T 335 LS 3522M E T EH3M9217T 419 L1 3524M E T H3M9218T 300 LS 3526M E T EH3M9218T 407 L1 3528M E T H3M9221T 356 LS 3528M E T EH3M9221T 425 L1 3530M E T H3M9222T 325 LS 3540M E T EH3M9222T 438 L1 3542M E T H3M9225T 368 LS 3535M E T EH3M9225T 465 L1 3540M E T H3M9226T 358 LS 3628M E T EH3M9226T 479 L1 3635M E / T H3M9228T 507 LS 3630M E / T EH3M9228T 738 L1 3634M E / T H3M9229T 500 LS 3726M E / T EH3M9229T 705 L1 3732M E T H3M9231T 636 LS 3725M E T EH3M9231T 841 L1 3730M E T H3M9232T 627 LS 3738M E T EH3M9232T 855 L1 3744M E T H3M9233T 930 LS 3735M E T EH3M9233T 1198 L1 3740M E T H3M9235T 940 LS 3750M E T EH3M9235T 1211 L1 3756M E T H3M9238T 1188 LS 3750M E T EH3M9238T 1406 L1 3928M E T H3M9239T 1144 LS 3936M E T EH3M9239T 1522 L1 3940M E T H3M9241T 1437 LS 3934M E T H3M9242T 1388 LS 3942M E T EH3M9242T 1855 L1 4040M E TS H3M9244T 1522 LS 3936M E TS EH3M9244T 1993 L1 3948M E T H3M9246T 1603 LS 3952M E T EH3M9246T 2029 L1 4048M E TS H3M9248T 2144 LS 3950M E TS EH3M9248T 2571 L1 3956M E T H3M9249T 2068 LS 4049M E T EH3M9249T 2647 L1 4060M E T H3M9252T 2397 LS 4057M E T EH3M9252T 2922 L1 4066M E T H3M9255T 2959 LS 4250M E T EH3M9255T 3679 L1 4262M E T H3M9258T 3625 LS 4266M E T EH3M9258T 4519 L1 4276M E Volt Code Amps 104

105 Three Phase - HVAC Variable Torque - TEFC HVAC 1/2 thru thru 365T Applications: Heating, ventilation and air conditioning fans and blowers HVAC Features: Heavy gauge steel frame construction (1-10 hp), ball bearings, 1.15 service factor. Dynamically balanced rotors for reduced vibration and quiet operation. Suitable for mounting in any position. HM models meet EPAct efficiencies. EHM models have higher efficiencies. Farm Duty 60 Hz. F1 Mounting HZ HM9110T 292 LS 3426M E T EHM9110T 414 L1 3518M E / T HM9114T 298 LS 3524M E / T EHM9114T 431 L1 3524M E T HM9118T 312 LS 3528M E T EHM9118T 447 L1 3532M E T HM9122T 369 LS 3546M E T EHM9122T 503 L1 3630M E T HM9126T 422 LS 3634M E T EHM9126T 551 L1 3640M E / T HM9129T 542 LS 3735M E / T EHM9129T 794 L1 3735M E T HM9132T 661 LS 3740M E T EHM9132T 896 L1 3740M E T HM9135T 1131 LS 0756M F T EHM9135T 1382 L1 3940M E T HM9139T 1397 LS 0938M E T EHM9139T 1675 L1 0944M E T HM9142T 1733 LS 0956M E T EHM9142T 2193 L1 1052M F T HM9146T 2015 LS 1052M E T EHM9146T 2605 L1 1056M F T HM9149T 2691 LS 1248M E T EHM9149T 3405 L1 1254M F T HM9152T 2807 LS 1250M E T EHM9152T 3721 L1 1260M F T HM9155T 4204 LS 1450M E T EHM9155T 5951 L1 1460M F T HM9158T 5194 LS 1462M E T EHM9158T 6957 L1 1478M F 86.0 F3 Mounting 1/ H3M LS 3410M E / EH3M K 3410M E / H3M LS 3416M E / EH3M K 3420M E / H3M LS 3416M E / EH3M K 3419M E / H3M K 3420M E 1.5 3/ EH3M K 3424M E H3M LS 3416M E EH3M LS 3418M E HZ H3M LS 3426M E T EH3M9110T 414 L1 3518M E 1.5 NOTE: 60 Hz: E= /460 volts, E1= 230/460 usable at 208 volts, SHADED RATINGS ARE CAST IRON FRAMES E2= 230/460 volts, usable at 200 volts, F= 230/460 volts. See notes on pages 8 and 9, and inside back flap. Type C Dimension Volt Code Amps Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz Inverter/Vector & Controls Servo DC 105

106 HVAC Farm Duty Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz Three Phase - TEFC continued Hz. NOTE: 60 Hz: E= /460 volts, E1= 230/460 usable at 208 volts, E2 = 230/460 volts, usable at 200 volts., F = 230/460 volts. See notes on pages 8 and 9, and inside back flap. Type C Dimension HVAC F3 Mounting continued 1 1/ T H3M9112T 330 L1 3520M E / T EH3M9112T 425 L1 3522M E / T H3M9114T 298 LS 3524M E / T EH3M9114T 431 L1 3524M E T H3M9117T 380 L1 3526M E T EH3M9117T 466 L1 3532M E T H3M9118T 312 LS 3528M E T EH3M9118T 447 L1 3532M E T H3M9121T 455 LS 3535M E T EH3M9121T 516 L1 3532M E T H3M9122T 369 LS 3546M E T EH3M9122T 503 L1 3630M E T H3M9125T 523 LS 3630M E T EH3M9125T 571 L1 3634M E T H3M9126T 422 LS 3634M E T EH3M9126T 551 L1 3640M E / T H3M9128T 771 LS 3640M E / T EH3M9128T 858 L1 3728M E / T H3M9129T 542 LS 3735M E / T EH3M9129T 794 L1 3735M E T H3M9131T 808 LS 3732M E T EH3M9131T 870 L1 3738M E T H3M9132T 661 LS 3740M E T EH3M9132T 896 L1 3740M E T H3M9133T 1280 LS 3750M E T EH3M9133T 1341 L1 3936M F T H3M9135T 1131 LS 3756M E T EH3M9135T 1382 L1 3940M E T H3M9139T 1397 LS 3948M E T EH3M9139T 1675 L1 3952M E Volt Code Amps Inverter/Vector & Controls Servo DC 106

107 Single Phase (PSC) - Direct Drive Fan - TEAO, Resilient and Rigid Base HVAC 1/4 thru 3/4 48Z thru 56Z Applications: Confinement houses, exhaust fans, air handling fans, unit heaters. Features: Double sealed ball bearings, rugged steel frame, corrosion resistant epoxy finish. 1 extended thru bolts. Permanent split capacitor. HVAC Farm Duty 60 Hz. NOTE: 60 Hz: B =115/230, B1= 115/230 usable at 208 volts. See notes on pages 8 and 9, and inside back flap. V-dimension on 48Z is 2.5 and V-dimension on 56Z is 3. Capacitor start, induction run. Three Phase - ODP Condenser Fan, Belly Band Round Body 1/2 thru 1 1/2 48YZ and 56YZ Applications: Designed specifically for use on commercial refrigeration condenser units and air conditioning units. Features: Corrosion resistant finish, ball bearings, dynamically balanced for quiet operation. Automatic reset thermal. Shaft 6 long - keyway and flat are 90 apart. Reconnectable leads in pulley endplate. 1/ YZ CFM3036A 368 K 3418M E 1.2 1/ YZ CFM3136A 381 K 3516M E 1.2 3/ YZ CFM3046A 400 K 3428M E 1.5 3/ YZ CFM3146A 412 K 3520M E YZ CFM3156A 470 K 3524M E / YZ CFM3166A 512 K 3535M E 2.5 NOTE: 60 Hz: E= /460 volts. See notes on pages 8 and 9, and inside back flap. Type C Dimension Resilient Base 1/ Z CHC3413A 258 K 3414C B 2.4 1/ Z CHC3414A 306 K 3418C B 2.2 1/ Z CHC3416A 281 K 3418C B 2.8 1/ Z CHC3417A 353 K 3421C B 2.8 1/ Z CHL3523A 316 K 3421L B / Z CHC3524A 316 K 3421C B 3.4 1/ Z CHC3525A 405 K 3528C B 3.6 1/ Z CHC3526A 501 K 3535C B 4.6 3/ Z CHC3528A 480 K 3535C B 4.5 Rigid Base 1/ Z PSC3413A 259 K 3411C B 1.3 1/ Z PSC3416A 288 K 3414C B 1.8 1/ Z PSC3524A 316 K 3418C B Hz. Type C Dimension Volt Code Volt Code Amps Amps Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz Inverter/Vector & Controls Servo DC 107

108 HVAC Farm Duty Three Phase - TEAO, Rigid Base HVAC 1/4 thru thru 254T Applications: In the Airstream and fan-on-shaft applications. Features: Locked drive end bearing construction, bearings sized for larger overhung loads for fan-on-shaft applications. Leads 36. Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz 60 Hz. NOTE: 60 Hz: E1=230/460 usable at 208 volts, E= /460 volts. See notes on pages 8 and 9, and inside back flap. Type C Dimension Volt Code Amps Minimum Airflow Ft/Min 1/ AOM K 3410M E / AOM K 3410M E / AOM K 3413M E / AOM K 3416M E T AOM3546T 321 L1 3428M E T AOM3556T 408 L1 3524M E T AOM3617T 790 L1 3623M E / T AOM3554T 335 L1 3516M E / T AOM3607T 466 L1 3617M E T AOM3558T 355 L1 3520M E T AOM3614T 500 L1 3623M E T AOM3702T 1200 L1 3726M E T AOM3611T 416 L1 3620M E T AOM3704T 627 L1 3723M E T AOM3705T 1311 L1 3735M E T AOM3615T 481 L1 3634M E T AOM3708T 898 L1 3735M E T AOM25904T 2085 L1 3936M E / T AOM3710T 617 L1 3729M E T AOM3714T 749 L1 3740M E Inverter/Vector & Controls Servo DC 108

109 Single Phase Farm Duty 1/3 thru thru 215T Applications: Wide variety of agri-duty and industrial applications. HVAC Features: Ball bearings, lubricated with high temperature moisture-resistant grease. Condensation drains, gasketed cast conduit boxes. Farm duty epoxy paint for protection from harsh environments Service Factor. Farm Duty 60 Hz. NOTE: 60 Hz: B= 115/230, B1=115/230 usable at 208 volts, C= 230, Flexible waterproof cover protects thermal overload reset button on 1/2 through = cooling fan on each end. See notes on pages 8 and 9, and inside back flap. Type C Dimension C-Face less Base 1/ C VFDL3501M 354 K 3414L B / C VFDL3504M 407 K 3421L B / C VFDL3507M 474 K 3432LC B C VFDL3510M 539 K 3524L B / C VFDL3514M 612 K 3532LC B 9.0 C-Face with Base 1/ C CFDL3501M 367 K 3414L B / C CFDL3504M 421 K 3421L B / C CFDL3507M 491 K 3432LC B CH CFDL3510M 557 K 3524L B / CH CFDL3514M 627 K 3532LC B CHZ CFDL3516TM 797 K 3535LC C 8.3 Rigid Base 1/ FDL3501M 271 K 3414L B / FDL3504M 318 K 3421L B / FDL3507M 375 K 3432LC B /56H FDL3510M 427 K 3524L B T FDL3510TM 427 L1 3524L B / /56H FDL3514M 481 K 3532LC B / T FDL3514TM 481 L1 3532LC B 9.0 Extra HIgh Torque - Capacitor start, Capacitor run - C-Face less Base TC VFDL3516TM 795 L1 3535LC C TC VFDL3610TM 1078 L1 3640LC C TC VFDL3612TM 1320 L1 3646LC C 23.0 Rigid Base HZ FDL3516TM 685 K 3535LC C T FDL3611TM 770 L1 3634L B FDL3611M 770 L1 3634L B FDL3610M 917 L1 3640LC C T FDL3610TM 917 L1 3640LC C T FDL3619TM 737 L1 3634LC C T FDL3612TM 964 L1 3646LC C FDL3731M 1154 L1 3735LC C / T FDL3733TM 1257 L1 3744LC C / FDL3732M 1332 L1 3744LC C T 1382 L1 3750LC C T 1473 L1 3750LC C 40.0 Volt Code Amps Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz Inverter/Vector & Controls Servo DC 109

110 HVAC Farm Duty Three Phase - TEAO, Rigid Base Farm Duty 1/4 thru thru 215T Applications: In the Airstream and fan-on-shaft applications. Features: Locked drive end bearing construction, bearings sized for larger overhung loads for fan-on-shaft applications. 36 Leads. Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz 60 Hz. NOTE: 60 Hz: E1=230/460 usable at 208 volts, E = /460 volts. See notes on pages 8 and 9, and inside back flap. Type C Dimension Volt Code Amps Minimum Airflow Ft/Min 1/ AOM K 3410M E / AOM K 3410M E / AOM K 3413M E / AOM K 3416M E T AOM3546T 321 L1 3428M E T AOM3556T 408 L1 3524M E T AOM3617T 790 L1 3623M E / T AOM3554T 335 L1 3516M E / T AOM3607T 466 L1 3617M E T AOM3558T 355 L1 3520M E T AOM3614T 500 L1 3623M E T AOM3702T 1200 L1 3726M E T AOM3611T 416 L1 3620M E T AOM3704T 627 L1 3723M E T AOM3705T 1311 L1 3735M E T AOM3615T 481 L1 3634M E T AOM3708T 898 L1 3735M E T AOM25904T 2085 L1 3936M E / T AOM3710T 617 L1 3729M E T AOM3714T 749 L1 3740M E Inverter/Vector & Controls Servo DC 110

111 Single and Three Phase - Grain Dryer/Centrifugal Fan - ODP and TEFC, Rigid Base Farm Duty 5 thru TZ thru 326TZ Applications: High pressure grain drying and storage for commercial and farm applications. Features: Shaft length is 1 longer than standard. Screens to protect against entry of trash, snakes and rodents. Three phase ratings meet EPAct efficiencies. HVAC Farm Duty 60 Hz. Open Drip Proof, Single Phase TZ GDL1605T 1058 L1 3646LC C TZ GDL1607T 1392 L1 3744LC C TZ GDL1610T 1612 L1 3750LC C TZ GDL1615T 2400 L1 3956LC C 65.0 Open Drip Proof, Three Phase TZ GDM3218T 585 L1 3628M E / TZ GDM3311T 830 L1 3646M E TZ GDM3313T 1007 L1 3738M E TZ GDM2513T 1240 L1 3752M E TZ GDM2515T 1633 L1 3936M E TZ GDM2531T 2006 L1 3942M E TZ GDM2535T 2334 L1 3952M E Totally Enclosed Fan Cooled, Three Phase TZ GDM3611T 586 L1 3535M E TZ GDM3615T 678 L1 3634M E / TZ GDM3710T 864 L1 3735M E TZ GDM3714T 1396 L1 3740M F TZ GDM2333T 1845 L1 0748M E TZ GDM2334T 1975 L1 0938M E TZ GDM4103T 2812 L1 0956M E TZ GDM4104T 3321 L1 0964M E TZ GDM4110T 4411 L1 1240M E TZ GDM4115T 4569 L1 1246M E NOTE: 15 single phase centrifugal fan motors require an AC contactor in start circuit (See chart below). SHADED RATINGS ARE CAST IRON FRAMES 60 Hz: C = 230, E1=230/460 usable at 208 volts, E = /460 volts, F = 230/460 volts. See notes on pages 8 and 9, and inside back flap. Type C Dimension Volt Code Amps Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz Inverter/Vector & Controls AC Contactor with Class 1 General Purpose Enclosure ABBAA A8 7 Servo DC 111

112 HVAC Farm Duty Single and Three Phase - Grain Dryer/Vane Axial Fan - TEAO and OAO, Rigid Base Farm Duty 3 thru TZ thru 215Z Applications: Vane axial fan crop dryers. Features: Shaft 3/4 longer than standard, shaft keyed, drilled and tapped with internal 1/4-20 tap 1 deep Service Factor. Thermostats. Epoxy paint. Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz Inverter/Vector & Controls 60 Hz. NOTE: 60 Hz: C = 230, D1= 230 usable at 208 volts, E1= 230/460 usable at 208 volts, F = 230/460 volts, E = /460 volts. See notes on pages 8 and 9, and inside back flap. Type C Dimension Totally Enclosed Fan Cooled, Single Phase TZ UCLE L1 3532LC D TZ UCLE L1 3540LC C TZ UCLE L1 3646LC C TZ UCLE L1 3646LC C 38.0 Open Air Over, Single Phase TZ UCL L1 3532LC C TZ UCL L1 3540LC C Z UCL L1 3634L C TZ UCL L1 3646L C TZ UCL L1 3646LC C Z UCL L1 3729L C Z UCL L1 3744LC C Z UCLE L1 3750LC C 46.0 Totally Enclosed Air Over, Three Phase Z UCME L1 3628M E TZ UCME L1 3524M E TZ UCME L1 3528M E TZ UCME L1 3628M E TZ UCME L1 3640M E TZ UCME L1 3640M E Z UCME L1 3733M E 16.5 Open Air Over, Three Phase TZ UCM L1 3524M E TZ UCM L1 3528M E Z UCM L1 3532M E TZ UCM L1 3628M F TZ UCM L1 3646M E Z UCM L1 3726M E 18.0 Volt Code Amps Servo DC 112

113 Single Phase PSC (switchless) - Universal Crop Dryer - TEAO and OAO 60 Hz. Farm Duty 3 thru Z thru 215Z Applications: Specifically engineered for use on vane axial fan crop dryers. Features: TEAO design prevents entrance of rodents, insects and other foreign matter. High full load efficiency for reduced operating cost. No mechanical switch to wear. No noise and vibration from regeneration. Less sensitive to voltage variations. Soft start. Thermostats. Epoxy paint Service Factor. Totally Enclosed Air Over Z UCCE L1 3634C C TZ UCCE L1 3640C C TZ UCCE L1 3646C C Z UCCE L1 3729C C Z UCCE L1 3744C C 50.0 Open Air Over TZ UCC L1 3634C C TZ UCC L1 3640C C Z UCC L1 3740C C 41.0 NOTE: 60 Hz: C = 230 volts. See notes on pages 8 and 9, and inside back flap. Type C Dimension Volt Code Amps HVAC Farm Duty Definite Purpose Brake 200 & 575 Volt IEC Three Phase, Irrigation Tower Drive - TENV, C-Face, No Base 1 56 Applications: Irrigation tower drive motors. Features: Sealed fit at endplates. Sheds water. Conduit box cast into front endplate. Epoxy paint. High overload capabilities. The P indicates less pulley endplate for integral mounting; can be field modified for older designs with internal thru bolts. 50 Hertz Inverter/Vector & Controls 60 Hz. NOTE: 50//60 Hz: N = 380//460 volts. See notes on pages 8 and 9, and inside back flap. Gearbox not included in price. Type C Dimension less Pulley Endplate / YZ IM3540A-P 460 K 3524M N 1.8 Complete (As pictured) / C IM3540A 474 K 3524M N 1.8 Volt Code Servo DC Amps 113

114 HVAC Farm Duty Definite Purpose Single Phase - Auger Drive - TEFC, Flange Mount Capacitor Start Farm Duty 1/3 thru 1 1/2 56N Flange Applications: Poultry feed auger drive systems. Mechanical Features: Mechanical protection of centrifugal switch to prevent damage to motor in case of overspeed. Manual reset thermal protection mounted in oversize conduit box. Farm Duty epoxy paint and thermal cover protect motor from harsh environments. Extended shaft (fan end) with wrench flats for manual jogging of auger. 56N flange connects to the drive/gear box assembly. Gear reducer is assembled to motor. Electrical Features: High efficiency design. Moisture resistant 200 C copper windings. Stator and steel frame dipped and baked in 100% solid polyester non-hygroscopic varnish. Heavy duty Type 1 capacitor. Brake 200 & 575 Volt 60 Hz. Type NOTE: 60 Hz: B1=115/230 volts usable at 208 volts. See notes on pages 8 and 9, and inside back flap. C Dimension 1/ YZ ANFL3501M 339 K 3414L B / YZ ANFL3504M 381 K 3421L B / YZ ANFL3507M 444 K 3428LC B YZ ANFL3510M 549 K 3524L B / YZ ANFL3514M 816 K 3532LC B1 9.0 Volt Code Amps IEC 50 Hertz Inverter/Vector & Controls Servo DC 114

115 Single Phase - Grain Stirring - TEFC, Rigid Base 1 1/2 56Z Applications: Inside bin grain stirring systems. Farm Duty HVAC Features: Corrosion resistant epoxy finish, slotted fan cover designed to prevent clogging. Manual thermal with cover. Farm Duty 60 Hz. NOTE: 60 Hz: C = 230. See notes on pages 8 and 9, and inside back flap. Type C Dimension 1 1/ Z GSL3509M 505 K 3528LC C 7.5 Volt Code Amps Definite Purpose Brake Single Phase - Instant Reversing - TEFC, Rigid Base 3/4 thru 2 56 thru 184 Applications: Farm applications such as barn cleaners, bulk feeders and industrial applications. Features: Farm Duty epoxy paint protects motor from harsh environments. Manual thermal with cover mounted in conduit box for protection, ball bearings, condensation drains, heavy gauge steel construction. 200 & 575 Volt IEC 60 Hz. NOTE: 60 Hz: C = 230. See notes on pages 8 and 9, and inside back flap. Type C Dimension 3/ IR3507M 418 K 3524L C IR3510M 454 K 3528L C / IR3603M 884 L1 3628L C IR3605M 919 L1 3634L C 11.5 Volt Code Amps 50 Hertz Inverter/Vector & Controls DC Servo 115

116 HVAC Farm Duty Single and Three Phase - Aeration Fan - TEAO, Rigid Base Farm Duty 3/4 thru 3 56 thru 145TZ Applications: Aeration fans for farm grain storage, exhaust fans, air handling systems, etc. Features: Lubrication fittings on T frames for easy on-site maintenance, ball bearings,corrosion protected with epoxy finish. Normallyclosed thermostats on three phase motors. Definite Purpose Brake 200 & 575 Volt 60 Hz. NOTE: 60 Hz: B = 115/230, B1 = 115/230 usable at 208, C = 230, E1= 230/460 usable at 208 volts, E = /460 volts. See notes on pages 8 and 9, and inside back flap. Type C Dimension Single Phase 3/ Z AFL3520A 258 K 3420L B AFL3521A 305 K 3524L B / AFL3525A 396 K 3528L B / TZ AFL3522A 424 L1 3528L B TZ AFL3523A 517 L1 3535L B TZ AFL3524A 541 L1 3535LC C 15.0 Three Phase 3/ Z AFM K 3413M E Z AFM K 3416M E / T AFM L1 3516M E T AFM L1 3528M E 3.8 Volt Code Amps IEC 50 Hertz Single Phase - Dairy/ Vacuum Pump - TEFC, Rigid Base 5 thru T thru 215T Applications: Vacuum pumps used in the dairy industry. Features: Manual thermal overload protected, heavy gauge steel frame Service Factor. 50 C ambient-continuous duty. Farm duty epoxy paint. Inverter/Vector & Controls Servo 60 Hz. NOTE: 60 Hz: C = 230. See notes on pages 8 and 9, and inside back flap. DEL3737TM has cooling fan on each end. Type C Dimension T DEL3708TM 1459 L1 3744LC C / T DEL3733TM 1915 L1 3750LC C T DEL3737TM 2339 L1 3750LC C 39.0 Volt Code Amps DC 116

117 Three Phase - Two Speed - TEFC, Rigid Base Definite Purpose 1 thru thru 324T Applications: Fans, blowers, machine tools, hoists, conveyors, pumps. HVAC Features: Lifting eye bolt mounted at top center 215T frame and larger for easy handling, copper windings, dynamically balanced rotors. Farm Duty 60 Hz. NOTE: 60 Hz: C = 230, D = , G = 460 volts. See notes on pages 8 and 9, and inside back flap. Type C Dimension 1725/850, Constant Torque, One Winding, Low Voltage / T M1504T 738 L1 3524M D / T M1505T 779 L1 3535M C / T M1506T 946 L1 3628M D / T M1507T 1072 L1 3640M C / T M1508T 1401 L1 3735M D / T M1509T 1825 L1 3744M C / T M1510T 2812 L1 0948M C 1725/850, Constant Torque, One Winding, High Voltage / T M1704T 738 L1 3524M G / T M1705T 779 L1 3535M G / T M1706T 946 L1 3628M G / T M1707T 1072 L1 3640M G / T M1708T 1401 L1 3735M G / T M1709T 1825 L1 3744M G / T M1710T 2812 L1 0948M G / T M1711T 3257 L1 0944M G / T M1712T 4138 L1 1046M G / T M1713T 5025 L1 1048M G 1725/850, Variable Torque, One Winding, Low Voltage / T M1554T 519 L1 3520M D / T M1555T 541 L1 3528M D / T M1556T 628 L1 3528M D / T M1557T 675 L1 3628M D / T M1558T 859 L1 3640M D / T M1559T 1223 L1 3740M C 1725/850, Variable Torque, One Winding, High Voltage / T M1754T 519 L1 3520M G / T M1755T 541 L1 3528M G / T M1756T 628 L1 3535M G / T M1757T 675 L1 3628M G / T M1758T 859 L1 3640M G / T M1759T 1211 L1 3740M G / T M1760T 1427 L1 3756M G / T M1761T 1972 L1 0934M G / T M1762T 2333 L1 1034M G / T M1763T 2707 L1 1040M G Volt Code SHADED RATINGS ARE CAST IRON FRAMES Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz Inverter/Vector & Controls Servo DC 117

118 HVAC Farm Duty Definite Purpose Brake 200 & 575 Volt Three Phase - Two Speed - TEFC, Rigid Base continued 60 Hz. NOTE: 60 Hz: C = 230, D = , G = 460 volts. See notes on pages 8 and 9, and inside back flap. Definite Purpose Type C Dimension 1725/1140, Variable Torque, Two Windings, Low Voltage / M K 3524M C / T M1520T 600 L1 3528M D / T M1521T 742 L1 3623M D / T M1522T 850 L1 3628M D / T M1523T 996 L1 3634M D / T M1524T 1560 L1 3735M C 1725/1140, Variable Torque, Two Windings, High Voltage / M K 3520M G / M K 3524M G / T M1720T 600 L1 3528M G / T M1721T 742 L1 3623M G / T M1722T 850 L1 3628M G / T M1723T 996 L1 3634M G / T M1724T 1560 L1 3735M G / T M1725T 2018 L1 0928M G / T M1726T 2323 L1 0750M G / T M1727T 2757 L1 1036M G / T M1728T 3739 L1 1046M G / T M1729T 3940 L1 1240M G Volt Code SHADED RATINGS ARE CAST IRON FRAMES IEC 50 Hertz Inverter/Vector & Controls Servo DC 118

119 Three Phase - Two Speed - ODP, Rigid Base Definite Purpose 1/2 thru thru 286T Applications: Fans, blowers, and pumps. HVAC Features: Lifting eye bolt mounted at top center 215T frame and larger for easy handling, copper windings, dynamically balanced rotors. Farm Duty 60 Hz. NOTE: 60 Hz: C = 230, D = , G = 460 volts. See notes on pages 8 and 9, and inside back flap. Type C Dimension 1725/850, Variable Torque, One Winding, Low Voltage / T M1004T 495 L1 3520M D / T M1005T 514 L1 3524M D / T M1006T 595 L1 3528M C / T M1007T 639 L1 3623M D / T M1008T 769 L1 3634M C / T M1009T 1099 L1 3735M C / T M1010T 1245 L1 3744M D 1725/850, Variable Torque, One Winding, High Voltage / T M1204T 495 L1 3520M G / T M1205T 514 L1 3524M G / T M1206T 595 L1 3528M G / T M1207T 639 L1 3623M G / T M1208T 769 L1 3634M G / T M1209T 1099 L1 3735M G / T M1210T 1245 L1 3744M G / T M1211T 1751 L1 3948M G / T M1212T 2146 L1 3948M G / T M1213T 2518 L1 4044M G 1725/1140, Variable Torque, Two Windings, Low Voltage / M K 3524M C / T M1020T 572 L1 3528M C / T M1021T 694 L1 3623M D / T M1022T 792 L1 3628M C / T M1023T 923 L1 3634M C / T M1024T 1421 L1 3735M C / T M1025T 1889 L1 3940M C 1725/1140, Variable Torque, Two Windings, High Voltage / M K 3520M G / M K 3524M G / T M1220T 572 L1 3528M G / T M1221T 694 L1 3623M G / T M1222T 792 L1 3628M G / T M1223T 923 L1 3634M G / T M1224T 1421 L1 3735M G / T M1225T 1889 L1 3940M G / T M1226T 2135 L1 3948M G / T M1227T 2590 L1 4044M G / T M1228T 3475 L1 4050M G / T M1229T 3731 L1 4050M G Volt Code Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz Inverter/Vector & Controls Servo DC 119

120 HVAC Farm Duty Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz Inverter/Vector & Controls Servo DC Single Phase - Pressure Washer - TEFC and ODP 60 Hz. Definite Purpose 1 1/2 thru 5 56 thru 184TC Applications: Pressure washers, steam cleaners, portable and self contained stationary system for direct drive mount and doubled mount designs. Features: Ball bearing design. 1 1/2 horsepower ratings are rated at 14 amps or less on 115 volts. Manual thermal overload located in the conduit box. U.L. and CSA recognized component approval. 200 C copper windings. NOTE: 60 Hz: B = 115/230, C = 230, D1 = 230 volts usable at 208 volts. See notes on pages 8 and 9, and inside back flap. Baldor 56H frames will also mount as 56,143T & 145T frames with 56 shaft dimensions. Baldor 56HZ will also mount as 56, 143T & 145T frames with 143T-145T shaft dimensions. Baldor 56HCY has non- BA dimension. Type C Dimension Totally Enclosed Fan Cooled, Rigid Base 1 1/ PL3513M 413 K 3520LC B / PL3514M 548 K 3535LC B PL3515M 499 K 3524LC B HZ L3516TM 679 K 3535LC C PL3519M 547 K 3532LC D T L3609TM 750 L1 3634LC B T L3608TM 864 L1 3640LC C T L3612TM 872 L1 3646LC C 23.0 Totally Enclosed Fan Cooled, Rigid Base with C-Face 1 1/ C PCL3513M 442 K 3520LC B / C PCL3514M 577 K 3535LC B C PCL3515M 524 K 3524LC B TC CL3516TM 685 L1 3535LC C C PCL3519M 574 K 3532LC D TC CL3619TM 955 L1 3634LC C TC CL3608TM 984 L1 3640LC C TC CL3612TM 1000 L1 3646LC C 23.0 Open Drip Proof, Rigid Base 1 1/ /56H PL1313M 358 K 3520LC B / PL1319M 476 K 3528LC B PL1317M 468 K 3524LC B PL1322M 499 K 3532LC B PL1326M 516 K 3532LC D T L1408TM 624 L1 3634LC B /56H PL1327M 532 K 3535LC D T L1410TM 759 L1 3640LC D Open Drip Proof, Rigid Base with C-Face 1 1/ C PCL1313M 389 K 3520LC B / C PCL1319M 499 K 3528LC B C PCL1317M 499 K 3524LC B C PCL1322M 517 K 3532LC B C PCL1326M 547 K 3532LC D TC CL1408TM 624 L1 3634LC B HCY PCL1327M 560 K 3535LC D TC CL1410TM 787 L1 3640LC D Volt Code Amps 120

121 Three Phase - Metering Pump - TEFC, Rigid Base 1/3 48 Definite Purpose Applications: Metering pump systems primarily used to inject chemicals into irrigation distribution systems. Features: TEFC industrial quality. Designed with conduit box at 12 o clock position to facilitate mounting on existing chemical injection pumps. Epoxy paint. Designed for use at 230/460 volts 60hz or 190/380 volts 50hz. HVAC Farm Duty 60/50 Hz. 60 Hz. 190/380//230/460 VAC, 50/60 Hz. 1/3 1725/ MPM K 3413M U NOTE: 60/50 Hz: K = 220/380/440 volts. U = 230/460//190/380. See notes on pages 8 and 9, and inside back flap. Three Phase - Arbor Saw - TEFC, Rigid Base 7 1/2 thru 15 Applications: Heavy duty circular saw applications. Machine tools. Features: Low profile for maximum blade cutting depth. Supplied with keyway and unthreaded shaft suitable for right or left threading. (See Mod Express Section for custom threading.) Double row ball bearings for maximum shaft stability in precision woodworking applications. NOTE: 60 Hz: E = /460 volts, F = 230/460. See notes on pages 8 and 9, and inside back flap. Type C Dimension 7 1/ ASM L1 6246M F ASM L1 6246M E ASM L1 7535M F ASM L1 6260M E ASM L1 7544M E Single Phase - Woodworking - TEFC Type C Dimension 1 thru 3 48Z thru 184YZ Applications: Woodworking equipment such as table saws, planers, etc. Volt Code Volt Code Features: swivels on rod for belt tensioning. Shaft supplied with full key and keyway. Extra high breakdown torques for maximum cutting power. Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz Inverter/Vector & Controls Servo 60 Hz. NOTE: 60 Hz: B = 115/230, C = 230. See notes on pages 8 and 9, and inside back flap. * WWL3509 is 48 base mount, not swivel mount. Type C Dimension Z WWL3509 * 322 K 3428L B TYZ WWL3515T 527 L1 3535LC B YZ WWL L1 3634L C 15.5 Volt Code Amps DC 121

122 HVAC Farm Duty Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz Inverter/Vector & Controls Servo DC 122 Three Phase - Chiller/Cooling Tower - TEAO 60 Hz. NOTE: 60 Hz: E = /460 volts, E1 = 230/460, usable at 208 volts, F = 230/460 volts. See notes on pages 8 and 9, and inside back flap. Red catalog number = New item Definite Purpose 5 thru T thru 365T Applications: For use in the airstream on chillers and cooling towers. Features: 1.15 Service Factor, corrosion resistant epoxy finish, double sealed bearings filled with moisture resistant grease, shaft seal/slinger, Class F insulation, moisture resistant copper windings, double dipped and baked, stainless steel nameplates and corrosion resistant hardware. Designed for wet, high humidity environments. ECTM Super-E motors have Premium efficiency and 3 year warranty. Direct replacement for most OEM applications. Type C Dimension Volt Code Amps Minimum Air Velocity (FPM) T ECTM3665T 780 L1 0643M E T CTM3665T 713 L1 0638M E T ECTM3768T 1239 L1 0744M E T CTM3768T 1083 L1 0735M E / T ECTM3770T 1040 L1 0740M E / T CTM3770T 951 L1 0735M E / T ECTM2276T 1765 L1 0954M E / T CTM2276T 1321 L1 0760M E T ECTM3774T 1168 L1 0750M E T CTM3774T 1214 L1 0740M E T ECTM2332T 2016 L1 0960M E T CTM2332T 1471 L1 0946M E T ECTM2333T 1606 L1 0936M E T CTM2333T 1613 L1 0756M F T ECTM4100T 2689 L1 1054M E T CTM4100T 2346 L1 1036M E T ECTM2334T 1947 L1 0952M E T CTM2334T 1799 L1 0938M E T ECTM4102T 3581 L1 1060M E T CTM4102T 2835 L1 1042M E T ECTM4103T 2547 L1 1046M E T CTM4103T 2181 L1 0956M E T ECTM4111T 4052 L1 1080M F T CTM4111T 3420 L1 1072M E T ECTM4104T 3023 L1 1060M E T CTM4104T 2617 L1 0964M E T ECTM4117T 4682 L1 1260M E T CTM4117T 4149 L1 1080M E T ECTM4110T 3953 L1 1260M E T CTM4110T 3483 L1 1248M E T ECTM4308T 5834 L1 1468M F T CTM4308T 4597 L1 1464M E T ECTM4115T 4008 L1 1266M E T CTM4115T 4111 L1 1080M E T ECTM4312T 7051 L1 1474M E T CTM4312T 5834 L1 1456M E T ECTM4314T 6218 L1 1462M E T CTM4314T 5564 L1 1454M E T ECTM4403T 8387 L1 1672M F T CTM4403T 7218 L1 1484M F T ECTM4316T 7271 L1 1482M E T CTM4316T 6689 L1 1476M E SHADED RATINGS ARE CAST IRON FRAMES

123 Single and Three Phase - Pre Rigid Base Definite Purpose 1/2 thru 5 66 thru 254 Applications: Applications requiring pre-1952 frame dimensions. HVAC Features: Heavy gauge seam welded base, ball bearings, copper windings. Farm Duty 60 Hz. Totally Enclosed Fan Cooled, Single Phase 1/ L3576M 396 K 3520L B 4.0 3/ L3565M 471 K 3524L B L3566M 512 K 3524L B / L3567M 621 K 3532LC B 8.0 Totally Enclosed Fan Cooled, Three Phase 1/ M K 3513M E / M K 3513M E M K 3516M E / M K 3520M E 2.5 Open Drip Proof, Single Phase L L1 3617L B / L L1 3623L B1 9.5 Open Drip Proof, Three Phase M L1 3614M E / M L1 3617M E M L1 3717M E M L1 3717M E M L1 3720M E 6.8 NOTE: 60 Hz: B = 115/230, B1= 115/230 usable at 208 volts, E1= 230/460 usable at 208 volts, E = /460 volts. See notes on pages 8 and 9, and inside back flap. Type C Dimension Volt Code Amps Definite Purpose Brake 200 & 575 Volt IEC Three Phase - Continuous Duty - SAE Hydraulic Pump 1 thru 10 56YZ thru 215TYZ Applications: Hydraulic pumps for lifts, trash compactors and other machinery Features: TEFC motors designed for continuous duty (may be used on intermittent duty applications). Base mount with SAE A or B pump mount face and shaft. F3 top-mounted conduit box. 50 Hertz Inverter/Vector & Controls 60 Hz. Type C Dimension YZ HPM K 3516M E 1 1/ TYZ HPM3550T 435 L1 3520M E TYZ HPM3555T 470 L1 3526M E TYZ HPM3611T 496 L1 3546M E TYZ HPM3615T 548 L1 3634M E 7 1/ TYZ HPM3710T 705 L1 3730M E TYZ HPM3714T 832 L1 3740M E Red catalog number = New item Volt Code Servo DC 123

124 HVAC Farm Duty Three Phase - F-2 Mount - TEFC and ODP, Rigid Base Definite Purpose 1 thru thru 364T Applications: Pumps, Compressors, Fans, Conveyors, Machine Tools and other applications requiring three phase F-2 mounted motors. Features: Copper windings, ball bearings, heavy gauge steel frame with base seam welded. EFM Super-E motors have Premium efficiency and 3 year warranty. Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz Inverter/Vector & Controls Servo 60 Hz. NOTE: 60 Hz: E1= 230/460 usable at 208 volts, E = /460 volts. See notes on pages 8 and 9, and inside back flap. Type C Dimension Totally Enclosed Fan Cooled T FM3558T 335 L1 3528M E T FM3611T 396 L1 3628M E T FM3615T 456 L1 3634M E / T FM3710T 582 L1 3735M E T FM3714T 708 L1 3740M E T EFM2333T 1452 L1 0936M E T EFM2334T 1759 L1 0948M E T EFM4103T 2301 L1 1046M E T EFM4104T 2733 L1 1060M E Open Drip Proof T EFM3116T 389 L1 3520M E / T EFM3154T 408 L1 3526M E T EFM3157T 436 L1 3532M E T EFM3211T 471 L1 3628M E T FM3211T 350 L1 3540M E T EFM3218T 516 L1 3632M E T FM3218T 387 L1 3628M E / T EFM3311T 759 L1 3732M E / T FM3311T 550 L1 3646M E T EFM3313T 919 L1 3744M E T FM3313T 674 L1 3738M E T EFM2513T 1303 L1 3938M E T FM2513T 1019 L1 3752M E T EFM2515T 1636 L1 3944M E T FM2515T 1313 L1 3936M E T EFM2531T 1994 L1 4046M E T FM2531T 1591 L1 3942M E T EFM2535T 2181 L1 4052M E T FM2535T 1860 L1 3952M E T EFM2539T 2846 L1 4250M E T FM2539T 2372 L1 4052M E T EFM2543T 3141 L1 4256M E T FM2543T 2785 L1 4060M E T EFM2547T 3954 L1 4278M E Volt Code Amps SHADED RATINGS ARE CAST IRON FRAMES DC 124

125 Three Phase - Automotive Approved - TEFC, Rigid Base 60 Hz. Definite Purpose 1 thru thru 445U Applications: Pumps, compressors, fans, conveyors, machine tools and other applications where automotive approved motors are required. AM Features: Approved by major US automobile manufacturers. Meets efficiency times power factor requirements per GM7EQ. All cast iron construction, regreasable double shield ball bearings, shaft slinger on both ends of motor, stainless steel nameplate, epoxy paint. Suitable for 65 C ambient 1.00 Service Factor or 1.15 Service Factor, 40 C ambient. Meets automotive requirements for sound power levels. AEM Features: Approved by major US automobile manufacturers. Meets efficiency times power factor requirements per GM7EQ. All cast iron construction, regreasable double shield ball bearings, shaft slinger on both ends of motor, stainless steel nameplate, epoxy paint. Suitable for 65 C ambient 1.00 Service Factor or 1.15 Service Factor, 40 C ambient. Meets automotive requirements for sound power levels. Meets GM for minimum efficiency times power factor requirements per GM7EHQ AM L1 0614M G AEM L1 0617M G AM L1 0620M G AEM L1 0628M G / AM L1 0617M G / AEM L1 0623M G / AM L1 0628M G / AEM L1 0634M G AM L1 0623M G AEM L1 0628M G AM L1 0726M G AEM L1 0726M G AM L1 0723M G AEM L1 0729M G AM L1 0740M G AEM L1 0740M G AM L1 0729M G AEM L1 0735M G U AM L1 0932M G U AEM L1 0752M G / U AEM L1 0924M G / U AM L1 0940M G / U AEM L1 0954M G U AEM L1 0932M G U AM L1 1040M G U AEM L1 1040M G U AEM L1 0942M G U AEM L1 1236M G U AEM L1 1044M G U AEM L1 1240M G U AEM L1 1246M G U AEM L1 1450M G 30.0 NOTE: 60 Hz: G = 460. See notes on pages 8 and 9, and inside back flap. SHADED RATINGS ARE CAST IRON FRAMES Type C Dimension Volt Code Amps HVAC Farm Duty Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz Inverter/Vector & Controls Servo DC 125

126 HVAC Farm Duty Definite Purpose Brake 200 & 575 Volt Definite Purpose Three Phase - Automotive Approved - TEFC, Rigid Base continued 60 Hz. NOTE: 60 Hz: G = 460. See notes on pages 8 and 9, and inside back flap. Type C Dimension U AEM L1 1250M G U AEM L1 1458M G U AEM L1 1448M G U AEM D3 1650M G U AEM L1 1458M G U AEM D3 1652M G U AEM D3 1654M G U AEM D3 1856M G U AEM D3 1880M G U AM D3 1864M G U AEM D3 1868M G U AEM D3 1864M G Volt Code Amps SHADED RATINGS ARE CAST IRON FRAMES IEC 50 Hertz Three Phase - Automotive - TENV, C-Face with Base 1/4 thru 1 56C Applications: Automotive approved motors for pumps, compressors, fans, conveyors, machine tools and other applications. Features: Double shield ball bearings, stainless steel nameplate, epoxy paint. Suitable for 65 C ambient 1.00 Service Factor or 1.15 Service Factor, 40 C ambient. Inverter/Vector & Controls Servo 60 Hz. Type NOTE: 60 Hz: F = 230/460, E = /460. See notes on pages 8 and 9, and inside back flap. C Dimension 1/ C CAM K 3513M F 0.5 1/ C CAM K 3513M E 0.6 1/ C CAM K 3513M E 0.9 1/ C CAM K 3516M E 0.8 3/ C CAM K 3516M E 1.1 3/ C CAM K 3520M E C CAM K 3520M E 1.4 Volt Code Amps DC 126

127 Three Phase - Oil Field Pump - Design D, High Slip, Rigid Base, TEFC & ODP Definite Purpose 3 thru T thru 447T Applications: Beam pumping units, punch presses and applications requiring high torque and high slip. Features: Two-part epoxy paint, moisture-resistant insulation, rodent screens, shaft slinger, F-2 position conduit box. TEFC motors have severe duty features. HVAC Farm Duty 60 Hz. NOTE: Voltage at 60 Hz: V = 230/460/796, V1 = 460/796 volts. SHADED RATINGS ARE CAST IRON FRAMES See notes on pages 8 and 9, and inside back flap. Custom TEFC motors available through 900 ; Open and WPII motors through Contact your Baldor Sales Representative. Red catalog number = New item Type C Dimension Volt Code Amps 460V Totally Enclosed Fan Cooled - 230/460/796 Twelve Lead and 460/796 Six Lead T OF3764T 1510 L1 0729M V T OF3768T 1672 L1 0750M V / T OF2276T 2041 L1 0932M V T OF2332T 2272 L1 0942M V T OF4100T 3626 L1 1040M V T OF4102T 4381 L1 1056M V T OF4111T 5286 L1 1250M V T OF4117T 6411 L1 1262M V T OF4308T 7104 L1 1466M V T OF4312T 9017 D3 1664M V T OF4403T D3 1680M V T OF4404T D3 1884M V T OF4409T D M V T OF4411T D M V T OF44156T D M V Drip Proof with Screens - 230/460/796 VAC Twelve Lead T OF3303T 922 L1 3729M V T OF3305T 1224 L1 3744M V / T OF3307T 1526 L1 3930M V / T OF3407T 1672 L1 0932M V T OF3310T 1850 L1 3938M V T OF3410T 1956 L1 0942M V T OF3315T 2596 L1 4032M V T OF3415T 2742 L1 1032M V T OF3320T 3110 L1 4040M V T OF3420T 3253 L1 1040M V 28.5 Drip Proof with Screens - 460/796 VAC Six Lead T OF3325T 3995 L1 4240M V T OF3425T 4251 L1 1240M V T OF3330T 4861 L1 4244M V T OF3430T 5142 L1 1246M V T OF3340T 6193 L1 4268M V T OF3440T 5789 L1 1446M V T OF3350T 7096 D3 1644M V T OF3360T 7973 L1 1654M V T OF3375T 9411 D3 1668M V T OF33100T 9999 D3 1864M V Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz Inverter/Vector & Controls Servo DC 127

128 HVAC Farm Duty Single Phase - Gate Operator - ODP, Resilient Base 1/3 thru 3/4 56H Definite Purpose Applications: Gate openers, hoists, greenhouse window openers and most medium start reversing applications. Features: Reversible, permanent split capacitor, manual reset thermal protection. Reconnectable leads opposite drive end endplate, ball bearings, 200 C moisture resistant magnet wire Service Factor. Definite Purpose Brake 200 & 575 Volt IEC 60 Hz. NOTE: 60 Hz: L =115. See notes on pages 8 and 9, and inside back flap. Single Phase - Door Operator - ODP, Rigid Base Type C Dimension 1/ H DGC1301M 286 K 3414C L 4.0 1/ H DGC1304M 321 K 3420C L 5.7 3/ H DGC1307M 385 K 3424C L 7.9 1/3 thru 3/4 56 Volt Code Amps Applications: Commercial door openers and most medium start reversing applications. Features: Reversible, capacitor start, 200 C moisture resistant magnet wire Service Factor. 50 Hertz Inverter/Vector & Controls 60 Hz. NOTE: 60 Hz: L = 115. See notes on pages 8 and 9, and inside back flap. Type C Dimension 1/ DOC K 3414C L 4.0 1/ DOC K 3420C L 5.7 3/ DOC K 3424C L 7.9 Volt Code Amps Servo DC 128

129 Three Phase - Super-E Premium Efficient - TEFC 60 Hz. Brake 1 thru thru 286T Applications: Machine tools, conveyors, door operators, speed reducers, any application requiring quick stops and positive hold. Features: Standard BA dimension. (c-face may be added in ModExpress). Spring set brake. Power off operation manual release. Resets automatically. have Premium Efficiency and inverter-ready. 230/460V brakes are connected in conduit box allowing for seperate connection when used with an inverter. C-Face with Base EBM K 3524M E T EBM3546T 952 L1 3524M E / T EBM3554T 1073 L1 3528M E T EBM3558T 1096 L1 3532M E T EBM3611T 1422 L1 3628M E T EBM3615T 1723 L1 3643M E / T EBM3710T 2312 L1 3744M E T EBM3714T 2858 L1 3750M E T EBM2333T 4045 L1 0936M E T EBM2334T 4905 L1 0952M E T EBM4103T 5521 L1 1046M E T EBM4104T 7478 L1 1060M E C-Face less Base C VEBM K 3524M E TC VEBM3546T 975 L1 3524M E / TC VEBM3554T 1096 L1 3528M E TC VEBM3558T 1119 L1 3532M E TC VEBM3611T 1467 L1 3628M E TC VEBM3615T 1768 L1 3643M E / TC VEBM3710T 2414 L1 3744M E TC VEBM3714T 2960 L1 3750M E NOTE: 60 Hz: E = /460 Volts, E1=230/460 usable at 208 volts. SHADED RATINGS ARE CAST IRON FRAMES have standard BA dimensions. = Brake motors may be mounted for vertical mounting with brake above or below motor. = Brake motors may be mounted for vertical mounting with brake below motor. = Class "F" insulated motor with 1.15 Service Factor or higher that operates within Class "B" temperature limits at rated horsepower. Red catalog number = New item Type C Dimension Volt Code Amps Brake Rating HVAC Farm Duty Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz Inverter/Vector & Controls DC Servo 129

130 HVAC Farm Duty Single and Three Phase - TEFC - Rigid Base Brake 1/4 thru thru 286T Applications: Machine tools, conveyors, door operators, speed reducers, any application requiring quick stops and positive hold. Features: Spring set brake. Power off operation manual release. Resets automatically. Brakes internally connected to motor on 215T and smaller. Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz Inverter/Vector & Controls Servo DC 60 Hz. NOTE: 60 Hz: B1= 115/230 usable at 208 volts, E1=230/460 usable at 208 volts, SHADED RATINGS ARE CAST IRON FRAMES E = /460 volts. Enclosed brake motors have non-standard BA dimension except for TENV ratings. = Brake motors may be mounted for vertical mounting with brake above or below motor. = Brake motors may be mounted for vertical mounting with brake below motor. See notes on pages 8 and 9, and inside back flap. Type C Dimension Volt Code Amps Single Phase 1/ BL K 3414L B / BL K 3414L B / BL K 3421L B / BL K 3428LC B BL K 3524L B Three Phase 1/ BM K 3413M E / BM K 3416M E / BM K 3420M E / BM K 3418M E / BM K 3420M E / BM K 3428M E BM K 3426M E T BM3546T 828 L1 3426M E BM L1 3516M E T BM3556T 1180 L1 3524M E / BM K 3520M E / T BM3554T 929 L1 3520M E / BM L1 3520M E BM K 3528M E T BM3558T 952 L1 3528M E BM L1 3528M E T BM3614T 1580 L1 3628M E T BM3611T 1291 L1 3623M E BM L1 3623M E T BM3704T 2342 L1 3726M E T BM3635T 1361 L1 3634M E T BM3615T 1602 L1 3634M E BM L1 3634M E / T BM3730T 1957 L1 3735M E / T BM3710T 2061 L1 3729M E T BM3734T 2171 L1 3740M E T BM3714T 2623 L1 3740M E T BM2353T 3175 L1 0744M E T BM2333T 3519 L1 0748M E T BM2354T 3690 L1 0938M E T BM2334T 4364 L1 0938M E T BM4103T 4621 L1 1034M E T BM4104T 6482 L1 1040M E Brake Rating 130

131 Single and Three Phase - TEFC - C-Face Brake 1/4 thru 10 56C thru 215TC Applications: Machine tools, conveyors, door operators, speed reducers, any application requiring quick stop and hold. Features: Spring set brake. Power off operation manual release. Resets automatically. Brakes internally connected to motor on 215T and smaller. HVAC Farm Duty 60 Hz. Single Phase 1/ C KBL K 3414L B / C KBL K 3421L B / C VBL K 3428LC B C VBL K 3524L B TC VBL3510T 898 L1 3524L B Three Phase, C-Face less Base 1/ C KBM K 3413M E / C KBM K 3416M E / C VBM K 3420M E / C VBM K 3428M E / C VBM K 3520M H C VBM K 3426M E TC VBM3546T 842 L1 3426M E TC VBM3546T L1 3516M H / C VBM K 3520M E / TC VBM3554T 944 L1 3520M E C VBM K 3528M E TC VBM3558T 969 L1 3528M E TC VBM3611T 1355 L1 3623M E TC VBM3615T 1674 L1 3634M E / TC VBM3710T 2144 L1 3729M E TC VBM3714T 2722 L1 3740M E Three Phase, C-Face with Base TC CBM3546T 869 L1 3516M E / TC CBM3554T 974 L1 3520M E TC CBM3558T 1001 L1 3528M E TC CBM3611T 1352 L1 3623M E TC CBM3615T 1691 L1 3634M E / TC CBM3710T 2157 L1 3729M E TC CBM3714T 2771 L1 3740M E NOTE: 60 Hz: B1= 115/230 usable at 208 volts, E = /460 volts, H = 575 volts. See notes on pages 8 and 9, and inside back flap. If brake motors are to be used with any electronic control, soft start, inverter or vector, etc. then brake must be externally connected. = Brake motors may be mounted for vertical mounting with brake above or below motor. = Brake motors may be mounted for vertical mounting with brake below motor. BRAKE INTERNALLY CONNECTED TO MOTOR ON 215T OR SMALLER FRAMES. Type C Dimension Volt Code Amps Brake Rating Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz Inverter/Vector & Controls Servo DC 131

132 HVAC Farm Duty Three Phase - ODP Brake 1/2 thru thru 254T Applications: Machine tools, conveyors, door operators, speed reducers, any application requiring quick stops and positive hold. Features: Spring set brake. Power off operation manual release. Resets automatically. Brakes internally connected to motor on 215T and smaller. Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz Inverter/Vector & Controls 60 Hz. NOTE: 60 Hz: E = /460, E1=230/460 usable at 208 volts, F = 230/460. See notes on pages 8 and 9, and inside back flap. If brake motors are to be used with any electronic control, soft start, inverter or vector etc., then brake must be externally connected. = Brake motors may be mounted for vertical mounting with brake above or below motor. = Brake motors may be mounted for vertical mounting with brake below motor. Type C Dimension Volt Code Amps Rigid Base 1/ BM K 3416M E / BM K 3420M E BM K 3424M E T BM3116T 728 L1 3424M E / T BM3154T 849 L1 3520M E T BM3157T 959 L1 3524M E T BM3211T 1183 L1 3623M E T BM3248T 1255 L1 3625M E T BM3218T 1485 L1 3625M E / T BM3311T 1815 L1 3726M E T BM3313T 2299 L1 3729M E T BM2513T 3078 L1 3750M F C-Face less Base 1/ C VBM K 3416M E / C VBM K 3420M E C VBM K 3424M E TC VBM3116T 743 L1 3424M E / C VBM K 3520M E / TC VBM3154T 864 L1 3520M E TC VBM3157T 974 L1 3524M E TC VBM3211T 1234 L1 3623M E TC VBM3218T 1532 L1 3625M E TC VBM3248T 1288 L1 3625M E Brake Rating Servo DC 132

133 Three Phase - Explosion Proof - C-Face Brake 3/4 thru 3 56C thru 215TC Applications: Machine tools, conveyors, door operators, speed reducers, any application requiring quick stops and hold. HVAC Features: Spring set brake. Power off operation manual release. Resets automatically. Explosion proof brakes require external connections. Farm Duty 60 Hz. 3/ C CBM K X3520M E TC CBM7014T L1 X3528M E TC CBM7023T L1 X3628M F TC CBM7027T L1 X3726M F NOTE: 60 Hz: E = /460, F = 230/460. See notes on pages 8 and 9, and inside back flap. 1 = Class I, Group D,T2C. = Brake motors may be mounted for vertical mounting with brake below motor.. Type C Dimension Volt Code Amps Brake Rating Definite Purpose Brake All Brake motors with 20 ft.-lb. or smaller brakes can be mounted horizontal or vertical. For larger ratings consult a Baldor District Office. All motors include manual release brake as standard. Brakes on non-explosion proof motors 10 and below are internally connected. 200 & 575 Volt IEC Double C-Face Brake Kits Coil voltage: 115/ Hertz Brake Rating Brake Mounting 3 lb-ft 56C CBK A lb-ft 56C CBK A lb-ft TC CBK A lb-ft TC CBK A lb-ft TC CBK A8 12 NOTE: Double C-Face coupler brakes. Mounts on motors with C-Face, provides C-face mounting on brake. Spring set, electrically released. See notes on pages 8 and 9, and inside back flap. Inverter/Vector & Controls Servo DC 133

134 HVAC Farm Duty Definite Purpose Brake 200 & 575 Volt Three Phase - Super-E Washdown - TEFC and TENV 60 Hz. NOTE: 60 Hz: E = /460 Volts, E1=230/460 usable at 208 volts, F = 230/460 volts, 60 Hz. 1 Amps at 460V - double for 230V. Efficiencies shown are nominal. Data subject to change without notice. Contact Baldor for certified data. Brake 1 thru 10 56C thru 184TC Applications: Food processing and other applications that regularly expose the motor to high pressure washdown. Features: Standard BA dimension 300 series stainless steel hardware, moisture sealant on bolt heads, between frame and end plates. Neoprone gaskets. Spring set brake internally connected to the motor. Power off manual release. Resets automatically. have Premium Efficiency and inverter-ready. 230/460V brakes are connected in conduit box allowing for separate connection when used with an inverter. Type C Dimension Volt Code Amps 1/ C CEWDBM K 3516M F / C CEWDBM K 3518M F C CEWDBM K 3526M E TC CEWDBM3546T 1370 L1 3526M E / TC CEWDBM3554T 1438 L1 3532M E TC CEWDBM3558T 1595 L1 3532M E TC CEWDBM3611T 1984 L1 3628M E TC CEWDBM3615T 2378 L1 3643M E Brake Rating IEC 50 Hertz Three Phase - High Cycle Brake 1/2 thru 2 56C thru 145TC Applications: Baggage conveyors and other applications requiring frequent starting and stopping. Features: Low inertia high efficiency motor with cast aluminum footless frame for increased thermal dissipation specific to this application. A DC brake with integral rectifier provides for faster action than traditional spring-set brakes. The brake coil is connected in the motor conduit box so it may be disconnected and separately excited if the motor is used with an inverter. Inverter/Vector & Controls Servo DC 60 Hz. Type C Dimension NOTE: 60 Hz: E = /460 Volts, E1=230/460 usable at 208 volts, F = 230/460 volts, 60 Hz. 1 Amps at 460V - double for 230V. Efficiencies shown are nominal. Data subject to change without notice. Contact Baldor for certified data. Red catalog number = New item Volt Code Amps 1/ C VRBM K 3420M E / C VRBM K 3428M E C VRBM K 3436M F / TC VRBM3554T 1341 L1 7528M E TC VRBM3558T 1376 L1 7535M E Brake Rating 134

135 Three Phase Volt - TEFC, Rigid Base 200 & 575 Volt 1 thru T thru 326T Applications: Pumps, fans, compressors, blowers, machine tools, conveyors and many other applications requiring 200 volt power. HVAC Features: 1.15 Service Factor, positively locked drive end bearing on 254T and larger, ball bearings, dynamically balanced rotors. EM Super-E motors have Premium efficiency and 3 year warranty. Farm Duty 60 Hz. Totally Enclosed Fan Cooled T EM3546T L1 3524M I T M3546T L1 3516M I / T EM3554T L1 3528M I / T M3554T L1 3520M I T EM3558T L1 3535M I T M3558T L1 3528M I T EM3660T L1 0628M I T EM3661T L1 0628M I T M3611T L1 3535M I T EM3663T L1 0634M I T EM3665T L1 0643M I T M3615T L1 3634M I / T EM3769T L1 0733M I / T EM3770T L1 0740M I / T M3710T L1 3729M I T EM3771T L1 0744M I T EM3774T L1 0750M I T M3714T L1 3740M I T EM2394T L1 0934M I T EM2333T L1 0936M I T M2333T L1 0748M I T EM4106T L1 0944M I T EM2334T L1 0952M I T M2334T L1 0938M I TS EM4107T L1 0950M I T EM4103T L1 1046M I T M4103T L1 0956M I TS EM4108T L1 0954M I T EM4104T L1 1060M I T M4104T L1 0964M I T EM4110T L1 1260M I T M4110T L1 1240M I T EM4115T L1 1266M I T M4115T L1 1080M I NOTE: TEFC 1 through 15 are 3 lead, 20 through 75 are 6 lead suitable for part winding start on 200 volts. SHADED RATINGS ARE CAST IRON FRAMES 60 HZ: I = 200 volt, I2 = 200 volt, 6 lead DOL or Part Winding Start. See notes on pages 8 and 9, and inside back flap. Type C Dimension Volt Code Amps Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz Inverter/Vector & Controls Servo DC 135

136 HVAC Farm Duty Three Phase Volt - ODP, Rigid Base 200 & 575 Volt 3/4 thru thru 404T Applications: Pumps, fans, compressors, blowers, machine tools, conveyors and many other applications requiring 200 volt power. Features: 1.15 Service Factor, positively locked drive end bearing on 254T and larger, ball bearings, dynamically balanced rotors. EM and EFM Super-E motors have Premium efficiency and 3 year warranty. Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz Inverter/Vector & Controls Servo 60 Hz. NOTE: ODP 1 through 15 are 3 lead, 20 through 100 are 6 lead suitable for part winding start on 200 volts. 60 Hz: I = 200 volt, I2 = 200 volt, 6 lead, DOL or Part Winding Start. See notes on pages 8 and 9, and inside back flap. Custom TEFC motors available through 900 ; Open and WPII motors through Contact your Baldor Sales Representative. Type C Dimension Open Drip Proof T EM3116T L1 3520M I T M3116T L1 3424M I / T EM3154T L1 3526M I / T M3154T L1 3520M I T EM3157T L1 3532M I T M3157T L1 3524M I T M3158T L1 3524M I T EM3211T L1 3628M I T M3211T L1 3535M I T M3212T L1 3535M I T EM3218T L1 3632M I T M3218T L1 3625M I / T M3219T L1 3628M I / T EM3311T L1 3732M I / T M3311T L1 3726M I T M3312T L1 3720M I T EM3313T L1 3746M I T M3313T L1 3729M I T M3314T L1 3729M I T EM2513T L1 3938M I T M2513T L1 3750M I T EM2514T L1 3932M I T M2514T L1 3930M I T EM2515T L1 3944M I T M2515T L1 3930M I T EM2516T L1 3940M I T M2516T L1 3928M I T EM2531T L1 4046M I T M2531T L1 3938M I TS M2534T L1 3938M I T EM2535T L1 4052M I T M2535T L1 3952M I Volt Code Amps DC 136

137 Three Phase Volt - ODP, Rigid Base continued 60 Hz. 200 & 575 Volt NOTE: ODP 1 through 15 are 3 lead, 20 through 100 are 6 lead suitable for part winding start on 200 SHADED RATINGS ARE CAST IRON FRAMES volts. 60 Hz: I = 200 volts, I2 = 200 volts, 6 lead DOL or Part Winding Start. See notes on pages 8 and 9, and inside back flap. Custom TEFC motors available through 900 ; Open and WPII motors through Contact your Baldor Sales Representative. Red catalog number = New item Type C Dimension TS EM2538T L1 4054M I TS M2538T L1 3946M I T EM2539T L1 4250M I T M2539T L1 4044M I T FM2539T L1 4044M I TS M2542T L1 4040M I T EM2543T L1 4256M I T M2543T L1 4060M I T EM2547T L1 4278M I T EM2551T L1 1462M I T EM2555T D3 4476M I Open Drip Proof, F2 Mount 3/ FM K 3420M I T EFM3157T L1 3532M I T EFM3211T L1 3628M I T EFM3218T L1 3632M I / T EFM3311T L1 3732M I / T FM3311T L1 3726M I T FM3313T L1 3729M I T EFM3313T L1 3746M I T EFM2513T L1 3938M I T FM2513T L1 3750M I T EFM2515T L1 3944M I T FM2515T L1 3930M I Volt Code Amps HVAC Farm Duty Definite Purpose Brake 200 & 575 Volt IEC DC Servo Inverter/Vector & Controls 50 Hertz 137

138 HVAC Farm Duty Three Phase Volt - TEFC 200 & 575 Volt Meets NRC Canadian standards for efficiency. 1/3 thru thru 445T Applications: Pumps, compressors, fans, conveyors, machine tools and other applications where 575 volt three phase power is available. Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz Inverter/Vector & Controls Servo DC 60 Hz. Features: Ball bearings. Mount in any position. Heavy gauge steel and cast iron frames. EM Super-E motors have Premium efficiency and 3 year warranty. Totally Enclosed Fan Cooled 1/ M LS 3413M H 0.6 1/ M K 3410M H 0.8 1/ M LS 3416M H 0.8 1/ M K 3418M H 1.0 3/ M K 3413M H 1.0 3/ M LS 3420M H 1.2 3/ T M3543T L1 3428M H M K 3416M H M LS 3516M H T EM3546T LS 3524M H T M3546T LS 3518M H T M3556T L1 3526M H / T M3550T L1 3520M H / T EM3554T LS 3528M H / T M3554T LS 3524M H / T M3607T L1 3625M H T M3555T L1 3526M H T EM3558T LS 3532M H T M3558T LS 3528M H T M3614T L1 3632M H T M3559T L1 3535M H T EM3611T LS 3628M H T M3611T LS 3546M H T EM3661T L1 0628M H T M3661T L1 0628M H T M3704T L1 3729M H T M3613T L1 3630M H T EM3615T LS 3643M H T M3615T LS 3634M H T EM3665T L1 0643M H T M3665T L1 0638M H T M3708T L1 3735M H / T M3616T L1 3640M H / T M3709T L1 3640M H / T EM3710T LS 3744M H / T M3710T LS 3735M H / T EM3770T L1 0740M H / T M3770T L1 0735M H T M3711T L1 3732M H T EM3714T LS 3750M H 10.1 NOTE: 60 Hz: H = 575 volts. SHADED RATINGS ARE CAST IRON FRAMES See notes on pages 8 and 9, and inside back flap. Type C Dimension Volt Code Amps 138

139 Three Phase Volt - TEFC continued Meets NRC Canadian standards for efficiency. 200 & 575 Volt HVAC 60 Hz. NOTE: 60 Hz: H = 575 volts. See notes on pages 8 and 9, and inside back flap. Custom TEFC motors available through 900 ; Open and WPII motors through Contact your Baldor Sales Representative. Type C Dimension T M3714T LS 3740M H T EM3774T L1 0750M H T M3774T L1 0740M H T EM2394T L1 0934M H T M3713T L1 3750M H T M2333T LS 0756M H T EM4106T L1 0944M H T M4106T L1 0750M H T M2334T LS 0938M H TS EM4107T L1 0950M H TS M4107T L1 0942M H T M4103T LS 0956M H TS EM4108T L1 0954M H TS M4108T L1 0954M H T M4104T LS 0964M H TS EM4109T L1 1244M H TS M4109T L1 1050M H T M4110T LS 1248M H TS EM4114T L1 1252M H TS M4114T L1 1064M H T M4115T LS 1080M H T M4314T LS 1454M H T M4316T LS 1462M H T M4400T LS 1480M H T M4410T LS 1868M H T M4406T LS 1884M H Volt Code Amps SHADED RATINGS ARE CAST IRON FRAMES Farm Duty Definite Purpose Brake 200 & 575 Volt IEC DC Servo Inverter/Vector & Controls 50 Hertz 139

140 HVAC Farm Duty Three Phase Volt - ODP 200 & 575 Volt Meets NRC Canadian standards for efficiency. 1/3 thru thru 404T Applications: Pumps, compressors, fans, conveyors, machine tools and other applications where 575 volt three phase power is available. Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz Inverter/Vector & Controls Servo DC 60 Hz. Features: Ball bearings. Mount in any position. Heavy gauge steel and cast iron frames. EM Super-E motors have Premium efficiency and 3 year warranty. Open Drip Proof 1/ M LS 3413M H 0.6 1/ M LS 3416M H 0.8 3/ M LS 3420M H M LS 3424M H T EM3116T L1 3520M H T M3116T LS 3518M H / T EM3154T L1 3526M H / T M3154T LS 3524M H T EM3157T L1 3532M H T M3157T LS 3528M H T EM3211T L1 3628M H T M3211T LS 3540M H T EM3218T L1 3632M H T M3218T LS 3628M H / T EM3311T L1 3732M H / T M3311T LS 3646M H T EM3313T L1 3746M H T M3313T LS 3738M H T EM2513T L1 3938M H T M2513T LS 3752M H T EM2515T L1 3944M H T M2515T L1 3936M H T EM2531T L1 4046M H T M2531T L1 3942M H T EM2535T L1 4052M H T M2535T L1 3952M H T EM2539T L1 4250M H T M2539T L1 4052M H T EM2543T L1 4256M H T M2543T L1 4060M H T EM2547T L1 4278M H T M2547T L1 4252M H T M2551T L1 4272M H T M2555T L1 4462M H T M2559T D3 4486M H T M2558T D3 1864M H NOTE: 60 Hz: H = 575 volts. SHADED RATINGS ARE CAST IRON FRAMES See notes on pages 8 and 9, and inside back flap. Type C Dimension Volt Code Amps 140

141 Three Phase Volt - Premium Efficient, Severe Duty - TEFC 200 & 575 Volt Meets NRC Canadian standards for efficiency. 1 thru T thru 445T HVAC Applications: Petro-chemical plants, mines, foundries, pulp and paper plants, waste management facilities, chemical plants, tropical climates and other processing industry applications requiring corrosion protection from severe environmental operating conditions. Features: 1.15 Service Factor. Corrosion resistant epoxy finish. Regreasable ball bearings. Oversized rotatable cast iron conduit box. Forsheda shaft seal. Moisture resistant copper windings. Class F insulation. Stainless steel nameplate and corrosion resistant hardware. Tropicalized. Premium efficiency, and 3 Year Warranty. Farm Duty Definite Purpose 60 Hz T ECP3581T L1 0524M H / T ECP3584T L1 0528M H T ECP3587T L1 0532M H T ECP3661T L1 0628M H T ECP3764T L1 0736M H T ECP3665T L1 0643M H T ECP3768T L1 0744M H / T ECP3770T L1 0740M H / T ECP2276T L1 0954M H T ECP3774T L1 0750M H T ECP2332T L1 0960M H T ECP2333T L1 0936M H T ECP4100T L1 1054M H T ECP2334T L1 0952M H T ECP4102T L1 1060M H T ECP4103T L1 1046M H T ECP4111T L1 1248M H T ECP4104T L1 1060M H T ECP4110T L1 1260M H T ECP4115T L1 1266M H T ECP4314T L1 1462M H T ECP4316T L1 1482M H T ECP4400T LS 1684M H T ECP4410T LS 1876M H T ECP4406T LS 1888M H T ECP4407T LS 18136M H NOTE: 60 Hz: H = 575 volts. SHADED RATINGS ARE CAST IRON FRAMES See notes on pages 8 and 9, and inside back flap. Type C Dimension Volt Code Amps Brake 200 & 575 Volt IEC 50 Hertz Inverter/Vector & Controls DC Servo 141

142 HVAC Farm Duty Three Phase - IEEE Volts, Rigid Base 200 & 575 Volt Meets NRC Canadian standards for efficiency. 1 thru T thru 449T Applications: Petro-chemical, pulp and paper plants, mines and other installations requiring premium efficient motors manufactured and tested to rigid standards for severe duty service. Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz Inverter/Vector & Controls 60 Hz. NOTE: 60 Hz: H = 575 volts. See notes on pages 8 and 9, and inside back flap. Custom TEFC motors available through 900 ; Open and WPII motors through Contact your Baldor Sales Representative. Features: Exceeds IEEE standards for severe duty TEFC induction motors. Premium efficiency copper windings using Baldor ISR (Inverter Spike Resistant ) magnet wire. InproSeal on fan and drive end shaft extensions, 2-part epoxy primer (inside & outside), gray epoxy paint and corrosion resistant hardware. Reduced noise, vibration and mechanical tolerances; final test and vibration results shipped with motor. Complies with Premium efficiency and 5 year warranty. Type C Dimension T ECP83581T L1 0524M H / T ECP83584T L1 0530M H T ECP83587T L1 0532M H T ECP83661T L1 0628M H T ECP83665T L1 0643M H / T ECP83770T L1 0740M H T ECP83774T L1 0750M H T ECP82333T L1 0936M H T ECP82334T L1 0952M H T ECP84103T L1 1046M H T ECP84104T L1 1060M H T ECP84110T L1 1260M H T ECP84115T L1 1266M H T ECP84314T L1 1462M H T ECP84316T L1 1482M H T ECP84400T D3 1684M H T ECP84410T D3 1876M H T ECP84406T D3 1888M H T ECP84407T D M H T ECP84408T D M H Volt Code Amps SHADED RATINGS ARE CAST IRON FRAMES Servo DC 142

143 Three Phase Volt - TEFC, C-Face 200 & 575 Volt Meets NRC Canadian standards for efficiency. 1/3 thru 25 56C thru 284TC HVAC 60 Hz. NOTE: 60 Hz: H = 575 volts. See notes on pages 8 and 9, and inside back flap. Applications: Pumps, fans, compressors, blowers, machine tools, conveyors and many applications requiring 575 volt power. Features: 1.15 Service Factor. Positively locked drive end ball bearing, dynamically balanced rotors. CEM Super-E motors have Premium efficiency and 3 year warranty. Type C Dimension C-Face with Base 1/ C CM LS 3413M H 0.6 1/ C CM LS 3416M H 0.8 3/ C CM K 3420M H C CM K 3424M H TC CM3546T L1 3518M H TC CEM3581T L1 0524M H / TC CEM3583T L1 0524M H / C CM K 3520M H / TC CEM3584T L1 0528M H / TC CM3554T L1 3524M H TC CEM3586T L1 0532M H C CM K 3528M H TC CEM3587T L1 0532M H TC CM3558T L1 3528M H TC CEM3660T L1 0628M H TC CM3559T L1 3535M H TC CM3610T L1 3535M H TC CEM3661T L1 0628M H TC CM3611T L1 3546M H TC CM3613T L1 3630M H TC CEM3663T L1 0634M H TC CM3615T LS 3634M H TC CEM3665T L1 0640M H / TC CEM3769T L1 0733M H / TC CM3710T LS 3735M H / TC CEM3770T L1 0740M H TC CM3711T L1 3732M H TC CEM3771T L1 0744M H TC CM3714T LS 3740M H TC CEM3774T L1 0750M H TC CM3713T L1 3750M H TC CM2333T L1 0756M H TC CEM2333T L1 0936M H TC CM2334T L1 0938M H TC CEM2334T L1 0948M H TC CEM4103T L1 1046M H 23.9 SHADED RATINGS ARE CAST IRON FRAMES Custom 575 volt motors available through Contact your local Baldor Sales Representative. Volt Code Amps Farm Duty Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz Inverter/Vector & Controls Servo DC 143

144 HVAC Farm Duty Definite Purpose Brake 200 & 575 Volt IEC Three Phase Volt - TEFC, C-Face continued Meets NRC Canadian standards for efficiency. 60 Hz. NOTE: 60 Hz: H = 575 volts. See notes on pages 8 and 9, and inside back flap. Type 200 & 575 Volt C Dimension C-Face less Base 1/ C VM LS 3413M H 0.6 1/ C VM K 3410M H 0.8 1/ C VM LS 3416M H 0.8 3/ C VM K 3413M H 1.0 3/ C VM LS 3420M H C VM K 3416M H C VM LS 3516M H TC VM3546T LS 3518M H / C VM K 3424M H / TC VM3550T L1 3424M H / C VM LS 3520M H / TC VM3554T LS 3524M H C VM K 3428M H C VM LS 3528M H TC VM3558T LS 3528M H C VM K 3528M H TC VM3610T L1 3535M H TC VM3611T LS 3546M H TC VM3613T L1 3630M H TC VM3615T LS 3638M H / TC VM3709T L1 3640M H / TC VM3710T LS 3735M H TC VM3711T L1 3732M H TC VM3714T LS 3740M H TC VM3713T L1 3750M H TC VM2333T L1 0938M H TC VM2334T L1 0938M H 19.3 Volt Code Amps SHADED RATINGS ARE CAST IRON FRAMES 50 Hertz Inverter/Vector & Controls Servo DC 144

145 Three Phase Volt, Close-Coupled Pump - TEFC and ODP 60 Hz. 200 & 575 Volt Meets NRC Canadian standards for efficiency. 1 thru JM thru 324JM Applications: Applications for circulating and transferring fluids. Commercial and industrial water pumps, etc. Features: Over-sized ball bearings with locked drive end construction for minimum shaft movement. Open drip-proof, close coupled pump motors are furnished with rodent screens at both ends. EJMM Super-E motors have Premium efficiency and 3 year warranty. Totally Enclosed Fan-Cooled - C-Face with Base JM JMM3546T L1 3516M H / JM JMM3550T L1 3516M H / JM JMM3554T L1 3520M H JM JMM3555T L1 3524M H JM JMM3558T L1 3528M H JM JMM3559T L1 3528M H JM JMM3610T L1 3620M H JM JMM3611T L1 3623M H JM JMM3613T L1 3628M H JM JMM3615T L1 3634M H / JM JMM3616T L1 3640M H / JM JMM3710T L1 3729M H JM JMM3711T L1 3735M H JM JMM3714T L1 3740M H JM JMM2394T L1 0744M H JM JMM2333T L1 0744M H JM JMM3713T L1 3744M H 13.7 Totally Enclosed Fan Cooled - C-Face less Base JM VJMM3546T L1 3516M H / JM VJMM3554T L1 3520M H JM VJMM3558T L1 3528M H JM VJMM3611T L1 3535M H JM VJMM3615T L1 3634M H / JM VJMM3710T L1 3735M H JM VJMM3714T L1 3740M H JM VJMM2333T L1 0744M H JM VJMM2334T L1 0944M H 19.1 Open Drip Proof - C-Face with Base JM JMM3158T L1 3524M H JM JMM3211T L1 3535M H JM JMM3212T L1 3535M H JM JMM3218T L1 3625M H / JM JMM3219T L1 3628M H / JM JMM3311T L1 3726M H JM JMM3312T L1 3720M H JM JMM3313T L1 3729M H JM JMM3314T L1 3729M H 14.5 NOTE: 60 Hz: H = 575 volts, E1 = 230/460 usable at 208 volts SHADED RATINGS ARE CAST IRON FRAMES See notes on pages 8 and 9, and inside back flap. Red catalog number = New item Type C Dimension Volt Code Amps HVAC Farm Duty Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz Inverter/Vector & Controls Servo DC 145

146 HVAC Farm Duty Three Phase Volt, Explosion Proof - Rigid Base and C-Face 200 & 575 Volt 1/2 thru thru 324T Applications: Shakers, blowers, pumps, mixers, etc. Features: All models have torques exceeding standards, copper windings, rotors that are corrosion treated and precision balanced Service Factor. UL and CSA approved for Class I, Group D or Class II, Group F & G. Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz Inverter/Vector & Controls 60 Hz. Rigid Base 1/ M K X3513M H 0.9 3/ M K X3513M H M K X3416M H M K X3516M H T M7014T L1 X3518M H / T M7018T L1 X3522M H / T M7034T L1 X3524M H T M7071T L1 X3526M H T M7037T L1 X3528M H T M7042T L1 X3628M H T M7072T L1 X3634M H T M7044T L1 X3638M H / T M7047T L1 X3735M H T M7170T L1 X0740M H T M7054T L1 X0944M H T M7056T L1 X0946M H T M7058T L1 X1046M H T M7060T L1 X1056M H T M7062T L1 X1256M H 37.6 C-Face less Base, No Drip Cover 1/ C VM K X3513M H 0.9 3/ C VM K X3513M H C VM K X3516M H TC VM7014T L1 X3518M H / TC VM7034T L1 X3524M H TC VM7037T L1 X3528M H TC VM7042T L1 X3628M H TC VM7044T L1 X3638M H / TC VM7047T L1 X3735M H 8.2 NOTE: 60 Hz: H = 575 volts. See notes on pages 8 and 9, and inside back flap. SHADED RATINGS ARE CAST IRON FRAMES. 8 = Class I, Group D, Class II, Group F & G, T3C. See page 4 for explosion proof classifications. Type C Dimension Volt Code Amps Servo DC CAUTION: Explosion-proof motors have a tight fit between mating parts to ensure the integrity of the explosion-proof enclosure. This can lead to an accumulation of moisture inside the motors due to condensation. Care should be used when selecting an explosion-proof motor, especially when installed outdoors and for intermittent duty. The Explosionproof motors are not suitable for use with adjustable speed drives. Inverter Duty Explosion-proof motors must be used. See page 163. See notes on pages 4 and

147 Three Phase - Metric IEC - 60 Hz kw/ 60 Hz. IEC IEC 230/460 Volt 60 Hz 18 thru 1.5 kw (.25 thru 2 ) IEC D63 thru D90L Applications: Replacement motors for equipment made in Europe requiring IEC metric frame mounting. Features: IP55 weather proof enclosure, aluminum frame construction. Conforms to IEC and IEC CSA and CSAus # (LR112981) B3 - Foot Mount - Rigid Base.18/ D63 MM K F / D63 MM K F / D63 MM K F / D71 MM K F / D71 MM K F / D71 MM K F / D71 MM K F / D80 MM K F / D80 MM K F / D80 MM K F / D80 MM K F / D90S MM K F / D90S MM K F / D90L MM K F 3.1 B5 - Flange Mount.18/ D63D MVM5100D 183 K F / D63D MVM5150D 190 K F / D63D MVM5200D 211 K F / D71D MVM5250D 218 K F / D71D MVM5300D 217 K F / D71D MVM5350D 225 K F / D71D MVM5400D 230 K F / D80D MVM5450D 245 K F / D80D MVM5500D 251 K F / D80D MVM5550D 264 K F / D80D MVM5600D 287 K F / D90SD MVM5650D 293 K F / D90SD MVM5700D 319 K F / D90LD MVM5750D 327 K F 3.1 B14 - Face Mount.18/ D63C MVM5100C 179 K F / D63C MVM5150C 185 K F / D63C MVM5200C 207 K F / D71C MVM5250C 213 K F / D71C MVM5300C 214 K F / D71C MVM5350C 222 K F / D71C MVM5400C 225 K F / D80C MVM5450C 239 K F / D80C MVM5500C 247 K F / D80C MVM5550C 260 K F / D80C MVM5600C 282 K F / D90SC MVM5650C 286 K F / D90SC MVM5700C 311 K F / D90LC MVM5750C 319 K F 3.1 NOTE: 60 Hz: F = 230/460 See notes on pages 8 and 9, and inside back flap. Q Dimension Volt Code Amps HVAC Farm Duty Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz Inverter/Vector & Controls Servo DC 147

148 HVAC Farm Duty Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz Inverter/Vector & Controls Servo DC 148 Three Phase - Metric IEC - 60 Hz kw/ 60 Hz. IEC IEC 575 Volt 60 Hz 18 thru 1.5 kw (.25 thru 2 ) IEC D63 thru D90L Applications: Replacement motors for equipment made in Europe requiring IEC metric frame mounting. Features: IP55 weather proof enclosure, aluminum frame construction. Conforms to IEC and IEC CSA and CSAus # (LR112981). B3 - Foot Mount - Rigid Base.18/ D63 MM K H / D63 MM K H / D63 MM K H / D71 MM K H / D71 MM K H / D71 MM K H / D71 MM K H / D80 MM K H / D80 MM K H / D80 MM K H / D80 MM K H / D90S MM K H / D90S MM K H / D90L MM K H 2.5 B5 - Flange Mount.18/ D63D MVM5100D K H / D63D MVM5150D K H / D63D MVM5200D K H / D71D MVM5250D K H / D71D MVM5300D K H / D71D MVM5350D K H / D71D MVM5400D K H / D80D MVM5450D K H / D80D MVM5500D K H / D80D MVM5550D K H / D80D MVM5600D K H / D90SD MVM5650D K H / D90SD MVM5700D K H / D90LD MVM5750D K H 2.5 B14 - Face Mount.18/ D63C MVM5100C K H / D63C MVM5150C K H / D63C MVM5200C K H / D71C MVM5250C K H / D71C MVM5300C K H / D71C MVM5350C K H / D71C MVM5400C K H / D80C MVM5450C K H / D80C MVM5500C K H / D80C MVM5550C K H / D80C MVM5600C K H / D90SC MVM5650C K H / D90SC MVM5700C K H / D90LC MVM5750C K H 2.5 NOTE: 60 Hz: H = 575 volts. See notes on pages 8 and 9, and inside back flap. Q Dimension Volt Code Amps

149 Three Phase - Metric IEC - 60 Hz IEC.18 thru 1.5 kw (.25 thru 2 ) IEC D63 thru D90L HVAC Farm Duty Dimensions IEC Ø D E f g h L Q R V Y Z d M M M6 90 S M8 90 L M8 Definite Purpose Brake B3 - Foot Mount IEC A B C H I K W S L & 575 Volt IEC B5 - Flange Mount IEC F Ø M Ø N O Ø P S S L Hertz Inverter/Vector & Controls B14 - Face Mount Servo DC IEC F Ø M Ø N O Ø P 63 M M M S M L M

150 HVAC Farm Duty Three Phase - 60 Hz -TEFC (IP54), Rigid Base (IEC-B3) IEC 0.18/0.25 thru 30/40 kw/ IEC D63 thru D200L Applications: Pumps, fans, conveyors, machine tools, gear reducers and other applications requiring IEC Metric B3 base mount replacements. Features: Conforms to IEC and IEC Conduit box mounted F-2, Rigid Base. Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz Inverter/Vector & Controls kw/ 60 Hz. IEC NOTE: 60 Hz: E1= 230/460 usable at 208 volts, E = /460, F = 230/460 volts See notes on pages 8 and 9, and inside back flap. Type C Dimension Rigid Base 0.18/ D63 MM K 3320M E / D63 MM K 3320M E / D71 MM K 3320M E / D71 MM K 3320M E / D71 MM K 3320M E / D71 MM K 3328M E / D80 MM K 3420M E / D80 MM K 3416M E / D80 MM K 3428M E / D80 MM K 3424M E / D90S MM K 3524M E / D90S MM K 3526M E / D90L MM K 3528M E / D90L MM K 3535M E / D100L MM L1 3628M E / D100L MM L1 3630M E / D112M MM L1 3634M E / D132S MM L1 3728M E / D132S MM L1 3735M E / D132S MM L1 3732M E / D132M MM L1 3740M E / D160M MM L1 0756M F / D160L MM L1 0944M E / D180M MM L1 0956M E / D180L MM L1 0964M E / D200L MM L1 1248M E Volt Code Amps SHADED RATINGS ARE CAST IRON FRAMES Servo DC 150

151 Three Phase - 60 Hz - TEFC (IP54), Flange (IEC-B5) IEC 0.25/0.33 thru 7.5/10 kw/ IEC D71D thru D132MD Applications: Pumps, fans conveyors, machine tools, gear reducers and other applications requiring IEC Metric B5 flange mount replacements. Features: IEC-B5 Flange mount, Conduit box mounted F-2. Conforms to IEC and IEC HVAC Farm Duty kw/ 60 Hz. IEC NOTE: 60 Hz: E1= 230/460 usable at 208 volts, E = /460 volts. See notes on pages 8 and 9, and inside back flap. Bases available, see page 152. Metric dimensions are located on back flap. Type C Dimension Flange with Oil Seal 0.25/ D71D MVM3457D 310 K 3320M E / D71D MVM3458D 374 K 3320M E / D71D MVM3460D 358 K 3320M E / D71D MVM3461D 377 K 3320M E / D71D MVM3463D 372 K 3328M E / D80D MVM3542D 398 K 3420M E / D80D MVM3545D 438 K 3416M E / D80D MVM3546D 455 K 3428M E / D80D MVM3550D 460 L1 3516M E / D90SD MVM3554D 469 L1 3520M E / D90LD MVM3555D 502 L1 3524M E / D90LD MVM3558D 486 L1 3528M E / D90LD MVM3559D 553 L1 3528M E / D100LD MVM3611D 598 L1 3623M E / D100LD MVM3613D 685 L1 3628M E / D112MD MVM3615D 645 L1 3634M E / D132SD MVM3709D 913 L1 3723M E / D132SD MVM3710D 814 L1 3729M E / D132SD MVM3711D 1082 L1 3735M E / D132MD MVM3714D 992 L1 3740M E 13.0 Volt Code Amps Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz DC Servo Inverter/Vector & Controls 151

152 HVAC Farm Duty Three Phase - 60 Hz - TEFC (IP54), B14 Face (IEC B14) IEC 0.25/0.33 thru 7.5/10 kw/ IEC D71C thru D112MC Applications: Pumps, fans, conveyors, machine tools, gear reducers and other applications requiring IEC Metric B14 face mounting replacements. Features: IEC- B14 face mounting, Conduit box mounted F-2. Definite Purpose Brake 200 & 575 Volt IEC kw/ 60 Hz. IEC NOTE: 60 Hz: E1= 230/460 usable at 208 volts, E = /460 volts. See notes on pages 8 and 9, and inside back flap. Type C Dimension B14 Face, /460 Volts 0.25/ D71C MVM3458C 329 K 3320M E / D71C MVM3460C 350 K 3320M E / D71C MVM3461C 370 K 3320M E / D71C MVM3463C 364 K 3328M E / D80C MVM3542C 389 K 3420M E / D80C MVM3545C 430 K 3416M E / D80C MVM3546C 444 K 3428M E / D80C MVM3550C 449 L1 3516M E / D90SC MVM3554C 460 L1 3520M E / D90SC MVM3555C 494 L1 3524M E / D90LC MVM3558C 473 L1 3528M E / D90LC MVM3559C 541 L1 3528M E / D100LC MVM3611C 586 L1 3623M E / D100LC MVM3613C 673 L1 3628M E / D112MC MVM3615C 632 L1 3634M E 6.6 Volt Code Amps 50 Hertz Inverter/Vector & Controls Metric Weld-on Bases IEC Description Baldor Type/ D71 MB /42 20 A8 1 D80 MB / A8 1 D90 MB / A8 2 D112 MB / A8 3 D132 MB / A8 6 Servo DC 152

153 Three Phase - 50 Hz - TEFC (IP54), B3 Face (IEC B5, B14) IEC 0.56/0.75 thru 15/20 kw/ IEC D80 thru D160L Applications: Pumps, fans, conveyors, machine tools, gear reducers and other applications requiring IEC metric motor replacements. Features: CE certified, Conforms to IEC and IEC , steel band motors have conduit box mounted on top with F-2 lead exit, Includes terminal blocks, cast iron conduct box in F-2 position. HVAC Farm Duty kw/ 50 Hz. IEC Rigid Base (IEC-B3) 0.75/ D80 MM K 3432M P / D90L MM K 3532M P / D100L MM L1 3628M P / D112M MM L1 3640M P / D132S MM L1 3729M W / D132M MM L1 3744M W / D160M MM L1 0756M W / D160L MM K 0948M W 29.0 Flange (IEC-B5) with Oil Seal 0.56/ D80D MVM3542D K 3424M P / D90LD MVM3558D L1 3532M P / D100LD MVM3611D L1 3628M P / D112MD MVM3615D L1 3640M P / D132SD MVM3710D L1 3729M W / D132MD MVM3714D L1 3744M W / D160MD MVM2333D L1 0940M W / D160LD MVM2334D L1 0948M W 29.0 Flange (IEC-B14) 1.5/ D90LC MVM3558C L1 3532M P / D100LC MVM3611C L1 3628M P / D112MC MVM3615C L1 3640M P / D132SC MVM3710C L1 3729M W / D132MC MVM3714C L1 3744M W 15.7 NOTE: 50 Hz: P= 230/400, W=400 volts DOL or Wye start, Delta-run. SHADED RATINGS ARE CAST IRON FRAMES See notes on pages 8 and 9, and inside back flap. Custom IEC frame motors are available through 670 kw (900 ) in TEFC enclosures and 1120 kw (1500 ) in ODP/WPII enclosures. Contact your local Baldor Sales Representative. Type C Dimension Volt Code Amps Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz Inverter/Vector & Controls DC Servo 153

154 HVAC Farm Duty Single Phase - - TEFC and ODP, Rigid Base 50 Hertz 1/3 thru 5 48 thru 213T Applications: Applications where only 50 hertz power is available. are designed to be used at rated voltages with tolerance of ±15% on voltage. Features: Windings tied each end at every slot for rigidity. Ball bearings, high temperature insulation, copper windings. Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz Inverter/Vector & Controls Servo 50 Hz. NOTE: 50 Hz: J = 110/220, M = 220. See notes on pages 8 and 9, and inside back flap. IP22= Open Drip Proof, IP54 = Totally Enclosed Fan Cooled. For IEC 50 Hz motors, see page 153. All motors listed above are specifically designed for operation with 50 Hz. power. Three phase, 50 Hz. motors shown in this catalog are suitable for use on 400 volt or 415 volt 50 Hz. power supplies. Type C Dimension Totally Enclosed Fan Cooled - IP54 1/ L K 3418L J 3.2 1/ L K 3420L J 3.3 1/ L K 3428L J 3.6 1/ L K 3428L J 3.6 3/ L K 3520L J 4.6 3/ L K 3524L J L K 3524L J L K 3532L J / L K 3532L J / L K 3535LC J / T L3514T L1 3535LC J L K 3535LC J T L3605T L1 3634LC J T L3609T L1 3646LC J T L3708T L1 3744LC M 22.0 Open Drip Proof - IP22 1/ L K 3416L J 2.6 1/ L K 3418L J 2.3 1/ L K 3420L J 3.3 1/ L K 3424L J 3.7 1/ L K 3424L J 3.7 3/ L K 3424L J 5.3 3/ L K 3524L J L K 3432L J L K 3528L J / L K 3528L J / L K 3528L J L K 3532L J T L1405T L1 3628L J T L1408T L1 3646LC J T L1508T L1 3735LC M 22.0 Volt Code Amps DC 154

155 Three Phase - - TEFC and ODP, Rigid Base 50 Hertz 1/2 thru thru 364T Applications: Applications where only 50 hertz power is available. are designed to be used at rated voltages with tolerance of ±15% on voltage. Features: Windings tied each end at every slot for rigidity. Ball bearings, high temperature insulation, copper windings. HVAC Farm Duty 50 Hz. Totally Enclosed Fan Cooled - IP54 1/ M K 3420M K 1.0 3/ M K 3413M K 1.4 3/ M K 3428M K M K 3420M K T M3546T L1 3520M K / T M3550T L1 3520M K / T M3554T L1 3524M K T M3555T L1 3524M K T M3558T L1 3532M K T M3610T L1 3535M K T M3611T L1 3628M K T M3613T L1 3634M K T M3615T L1 3640M K / T M3709T L1 3728M K / T M3710T L1 3729M K T M3711T L1 3733M K T M3714T L1 3744M K T M2333T L1 0756M K T M2334T L1 0948M K T M4103T L1 1044M K T M4104T L1 1056M K T M4110T L1 1256M K T M4115T L1 1268M K T M4314T L1 1462M K 75.0 Open Drip Proof - IP22 1/ M K 3420M K 1.0 3/ M K 3420M K M K 3516M K T M3116T L1 3520M K / T M3154T L1 3520M K T M3157T L1 3528M K T M3211T L1 3623M K T M3218T L1 3640M K / T M3311T L1 3735M K T M3313T L1 3740M K T M2513T L1 3756M K T M2515T L1 3938M K 27.0 NOTE: IP22= Open Drip Proof, IP54 = Totally Enclosed Fan Cooled. For IEC 50 Hz motors, SHADED RATINGS ARE CAST IRON FRAMES see page Hz: K = 220/380/440. Wye-start, delta-run on 220 and 440 volt only. See notes on pages 8 and 9, and inside back flap. M2513T-50 AND M2515T-50 conduit box location is at 12 o clock and can be rotated. All motors listed above are specifically designed for operation with 50 Hz. power. Three phase, 50 Hz. motors shown in this catalog are suitable for use on 400 volt or 415 volt 50 Hz. power supplies. Type C Dimension Volt Code Amps Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz Inverter/Vector & Controls Servo DC 155

156 HVAC Farm Duty Single and Three Phase - - TEFC, C-Face, No Base 50 Hertz 1/4 thru 2 56C thru 145TC Applications: Pumps, fans, gear reducers, conveyors and many other applications with 50 Hz power supply. designed to be used at rated voltage with tolerances of ±15%. Features: Heavy gauge steel frame construction, pressure cast aluminum end plates with machined steel bearing inserts for extended bearing life. Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz Inverter/Vector & Controls 50 Hz. NOTE: 50 Hz: J = 110/220, K = 220/380/440. Wye-start, delta-run on 220 and 440 volt only. See notes on pages 8 and 9, and inside back flap. IP54 = Totally Enclosed Fan Cooled. For IEC 50 Hz motors, see page 153. All motors listed above are specifically designed for operation with 50 Hz. power. Three phase, 50 Hz. motors shown in this catalog are suitable for use on 400 volt or 415 volt 50 Hz. power supplies. Type C Dimension Single Phase - IP54 1/ C VL K 3418L J 3.2 1/ C VL K 3420L J 3.3 1/ C VL K 3428L J 3.6 3/ C VL K 3520L J 4.6 3/ C VL K 3524L J C VL K 3524L J C VL K 3532L J / C VL K 3532L J / C VL K 3535LC J C VL K 3535LC J 9.7 Three Phase - IP54 1/ C KM K 3410M K 0.7 1/ C VM K 3413M K 0.7 1/ C VM K 3413M K 1.0 1/ C VM K 3420M K 1.0 3/ C VM K 3413M K 1.4 3/ C VM K 3428M K C VM K 3420M K TC VM3546T L1 3520M K / TC VM3550T L1 3520M K / TC VM3554T L1 3524M K TC VM3555T L1 3524M K TC VM3558T L1 3532M K 3.0 Volt Code Amps Servo DC 156

157 Single and Three Phase - - Explosion Proof, C-Face with Base 50 Hertz 1/3 thru 2 56C thru 184 C Applications: Pumps, blowers, valves. Features: Corrosion resistant epoxy finish. Positively locked drive end bearing. UL approved cast conduit box, standard Service Factor. UL and CSA approved for Class I, Group D or Class II, Group F & G. Rated for ±15% voltage variation. HVAC Farm Duty 50 Hz. NOTE: 50 Hz: J = 110/220, K = 220/380/440. Wye-start, delta-run on 220 and 440 volt only. See notes on pages 8 and 9, and inside back flap. 1 = Class I, Group D only, T2C. 7 = Class I, Group D, Class II, Group F & G, T4. 8 = Class I, Group D, Class II, Group F & G, T3C. For IEC 50 HZ motors, see page 153. CAUTION: Explosion-proof motors have a tight fit between mating parts to ensure the integrity of the explosion-proof enclosure. This can lead to an accumulation of moisture inside the motors due to condensation. Care should be used when selecting an explosion-proof motor, especially when installed outdoors and on intermittent duty. See notes on page 8. These explosion-proof motors are not suitable for use with adjustable speed drives. Inverter Duty explosion proof motors must be used. See page 163. Type C Dimension Single Phase - IP54 1/ C CL5001A K X3421L J 2.6 1/ C CL5004A K X3428L J 3.6 3/ C CL5007A K X3528L J C CL K X3532L J TC CL5027T L1 X3646L J 11.5 Three Phase - IP54 1/ C CM K X3420M K 1.0 3/ C CM K X3428M K C CM K X3420M K C CM K X3432M K / TC CM7018T L1 X3520M K / TC CM7034T L1 X3524M K TC CM7071T L1 X3524M K TC CM7037T L1 X3532M K 3.0 Volt Code Amps Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz Inverter/Vector & Controls DC Servo 157

158 HVAC Farm Duty Definite Purpose Brake 200 & 575 Volt AC Adjustable Speed Range Capabilities Inverter Drive and Vector Drive Baldor Inverter Drive and Vector Drive exceed all requirements of MG-1 Parts 30 and 31 for AC induction motors powered from adjustable speed controls. Definite- Purpose Inverter-Fed Polyphase, as defined for Inverter Drive are suitable for variable torque applications and rated 1000:1 for constant torque (except for those Inverter Duty motors rated for use in hazardous locations). Vector Drive motors are capable of full, rated torque at 0, continuous duty. Satisfactory motor performance depends on proper drive setup. It is necessary that motor-drive applications are commissioned by persons familiar with the operation and setup of adjustable speed drives, applicable electrical codes and any other regulations. Each drive must be tuned to the motor for the specific application. System operating parameters must be checked, including voltage at motor power leads, to insure that motor/drive set up has been successfully completed. Applications that are not properly set up can lead to substandard performance and failure of system components. Inverter Drive /Vector Drive & Controls Super-E All Baldor Super-E motors are Inverter-Ready and meet MG 1 Part Super-E motors are suitable for use with inverter drives in applications with variable torque and with a constant torque 20:1 speed rage except as noted below. inverter setup is unique to each specific application. Setup and correct wiring procedures must be closely followed. Standard-E Baldor Standard-E EPAct efficient motors are suitable for use in adjustable speed applications per MG 1 Part 30. With proper motor-inverter setup, Standard-E motors are suitable for use at 20:1 variable torque and 4:1 constant torque applications. Note: Use of explosion proof motors with inverters should be limited to Inverter-Duty Explosion proof motors only. Baldor Super-E 230, 460 and 575 Volts IEC Family Size Constant Torque Variable Torque Comments EM (TEFC) :1 20:1 General Purpose Premium Efficiency :1 20:1 EM (ODP) :1 20:1 General Purpose Premium Efficiency ECP :1 10:1 20:1 20:1 Severe Duty Premium Efficiency 50 Hertz ECP8 (IEEE841) :1 20:1 Severe Duty Premium Efficiency May not meet temp rise as specified in IEEE :1 20:1 when used with ASD. EWDM :1 20:1 Washdown Duty Premium Efficiency Inverter/Vector & Controls Servo Baldor Standard-E 230, 460 and 575 Volts Family Size Constant Torque Variable Torque Comments M (TEFC) :1 20:1 General Purpose M (ODP) :1 20:1 General Purpose CP :1 20:1 Severe Duty WDM :1 20:1 Washdown Duty Baldor Inverter Duty and Vector Duty 230, 460 and 575 Volts Family Size Constant Torque Variable Torque Comments IDM (TEBC) :1 1000:1 Inverter Duty/Blower cooled IDNM (TENV) :1 1000:1 Inverter Duty/Non-Vented ZDM (TEBC) :1 1000:1 Vector Duty/Blower Cooled DC ZDNM (TENV) :1 1000:1 Vector Duty/Non Vented IDXM :1 10:1 Explosion Proof Inverter Duty (2 families) :1 10:1 IDWNM :1 1000:1 Washdown Duty Inverter Duty/Non Vented 158 ZDWNM :1 1000:1 Washdown Duty Vector Duty/Non Vented

159 Three Phase - Inverter - TEBC and TENV, C-Face with Base 60 Hz. Max. Inverter Drive /Vector Drive & Controls 1/3 thru C thru 447T Applications: Conveyors, pumps, fans, metal processing, compressors, test stands, and material handling equipment. Features: Designed for inverter or vector applications where up to a 1000:1 constant torque speed range is required. Compatible with optional encoder feedback devices for use in closed loop velocity or position control. Meets MG1, Part 31. Encoder has mating connector. 1000:1 Constant Torque Speed Range NOTE: 60 Hz: F= 230/460, H=575. See notes on pages 8 and 9, and inside back flap. SHADED RATINGS ARE CAST IRON FRAMES Constant velocity fan: 115 volts, single phase from 143TC through 184TC and all 575 volt drive motors. Constant velocity fan: 230/460, three phase from 213TC through 447T. Consult District Office for availability of 2 pole motors and C-Face motors for 284T through 5009L frames.. 284T-447T motors are horizontal mount, no C-Face. May be converted to C-Face in Mod Express or built as custom motors. Red catalog number = New item Type C Dimension 1/ C IDNM E2 3513M F 0.6 1/ C IDNM E2 3516M F 0.8 3/ C IDNM E2 3520M F /2 1 1/2 1 1/2 1 1/ Volt Code TC IDNM3581T 828 E2 0524M F TC IDM3581T 1093 E2 0524M F TC IDM3581T E2 0524M H TC IDM3582T 1284 E2 0528M F TC IDNM3584T 912 E2 0532M F TC IDM3584T 1156 E2 0528M F TC IDM3584T E2 0528M H TC IDM3667T 1444 E2 0632M F TC IDNM3669T 954 E2 0628M F TC IDNM3587T 954 E2 0535M F TC IDM3587T 1236 E2 0535M F TC IDM3587T E2 0535M H TC IDM3664T 1484 E2 0640M F TC IDNM3661T 1097 E2 0634M F TC IDM3661T 1580 E2 0628M F TC IDM3661T E2 0628M H TC IDM3764T 1941 E2 0730M F TC IDNM3665T 1241 E2 0640M F TC IDNM3767T 1241 E2 0735M F TC IDM3665T 1672 E2 0640M F TC IDM3665T E2 0640M H TC IDM3768T 2377 E2 0740M F / TC IDNM2237T 1614 E2 0932M F / TC IDM3770T 1960 E2 0730M F / TC IDM3770T E2 0734M H / TC IDNM3770T 1614 E2 0750M F / TC IDM2276T 3418 E2 0954M F Amps TC IDNM2238T 1763 E2 0948M F TC IDM3774T 2023 E2 0750M F TC IDM3774T E2 0750M H TC IDM2332T 4176 E2 0960M F TC IDNM2333T 2013 E2 0948M F TC IDM2333T 2347 E2 0936M F TC IDM2333T E2 0936M H T IDM4100T 4951 E2 1054M F 18.7 HVAC Farm Duty Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz Inverter/Vector & Controls Servo DC 159

160 HVAC Farm Duty Definite Purpose Brake 200 & 575 Volt IEC Inverter Drive /Vector Drive & Controls Three Phase - Inverter - TEBC and TENV, C-Face with Base continued 1000:1 Constant Torque Speed Range Hz. Max. NOTE: 60 Hz: F= 230/460, G= 460. SHADED RATINGS ARE CAST IRON FRAMES (1) Includes 1024 ppr encoder. Constant velocity fan: 115 volts, single phase from 143TC through 184TC and all 575 volt drive motors. Constant velocity fan: 230/460 three phase from 213TC through 447T. Consult District Office for availability of 2 pole motors. 284T-447T motors are horizontal mount, no C-Face. May be converted to C-Face in Mod Express or built as custom motors. Type C Dimension Volt Code Amps T IDNM2334T 2882 E2 1056M F TC IDM2334T 2508 E2 0948M F TC IDM2334T E2 0948M H T IDM4102T 5575 E2 1060M F T IDM4103T 3092 E2 1046M F T IDM4111T 6354 E2 1248M F T IDM4104T 3548 E2 1056M F T IDM4117T 7071 E2 1254M F T IDM4110T 4797 E2 1256M F T IDM4308T 8134 E2 1464M F T IDM4115T 5385 E2 1262M F T IDM4312T 9379 E2 1474M F T IDM4314T 6211 E2 1462M F T IDM4403T E2 1662M F T IDM4316T 7235 E2 1482M F T IDM4404T E2 1680M F T IDM4400T E2 1684M G T IDM4409T E2 1888M G T IDM4410T E2 1868M G T IDM4406T E2 1888M G T IDM4407T E M G Hertz Inverter/Vector & Controls Servo DC 160

161 Three Phase - Inverter Washdown - TENV, C-Face with Base 60 Hz. Max. NOTE: 60 Hz: F = 230/460 volts. Use HS25 encoder kit when using optional encoder on page 167. See notes on pages 8 and 9, and inside back flap. Inverter Gear - Right Angle and Parallel Shaft -TEFC Inverter Drive /Vector Drive & Controls 1 thru TC thru 254TC Applications: Conveyors, pumps and other equipment in food processing and other wet environments. Features: Designed for inverter or vector applications where up to a 1000:1 constant torque speed range is required. Compatible with optional HS25 encoder feedback devices shown on page 167 for use in closed loop velocity or position control. Meets MG1, Part :1 Constant Torque Speed Range 3/8 Type C Dimension TC IDWNM3546T 975 E2 3524M F / TC IDWNM3554T 1075 E2 3535M F TC IDWNM3609T 1184 E2 3628M F TC IDWNM3611T 1291 E2 3634M F TC IDWNM3707T 1461 E2 3732M F / TC IDWNM22937T 2264 E2 3940M F TC IDWNM22938T 2652 E2 3956M F 12.0 Volt Code Amps Applications: Ideally suited for conveyors, material handing, packaging equipment applications requiring adjustable speed and no maintenance. Available in a broad range of gear ratios to meet your demanding application needs. HVAC Farm Duty Definite Purpose Brake 200 & 575 Volt IEC Input 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 Output 60 Hz. Gear Ratio Speed Range Features: ISR (Inverter Spike Resistant) magnet wire for increased protection against voltage spikes and corona damage. IP44 environmental protection. Designed for use on Baldor Series 15J, 15P and Series 5 Inverters operating on 230 volts output. Both Parallel shaft and Right Angle gearmotors are lubricated for life and require no routine maintenance. Right Angle gearmotors feature our internal oil expansion bladder which eliminates the need for a breather while allowing the gearmotor to be mounted in any position (see note below). Maximum Safe Torque 60 Hz NOTE: Avoiding those positions where the high speed oil seal is immersed in oil, will provide greater security against seal wear. Vertical motor below gearbox mounting is possible with modification, contact Baldor for details. 60 Hz: C = 230 volts Type & Gear Style Volt Code Right Angle IDGM E2 2528M-K 22 C IDGM E2 2528M-K 22 C IDGM E2 2528M-K 22 C IDGM E2 2528M-K 22 C IDGM E2 2528M-K 22 C IDGM E2 2528M-K 22 C 1.5 Parallel Shaft IDGMP E2 2528M-PSLH 20 C IDGMP E2 2528M-PSLH 20 C IDGMP E2 2528M-PSLH 20 C IDGMP E2 2528M-PSLH 20 C 1.5 Amps 50 Hertz Inverter/Vector & Controls Servo DC 161

162 HVAC Farm Duty Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz Inverter/Vector & Controls Three Phase - Inverter Ready, Paint Free Washdown - TEFC and TENV, C-Face 60 Hz. Max. NOTE: 60 Hz: E = /460 volts, F= 230/460 volts. Inverter Drive /Vector Drive & Controls 1/2 thru 10 56C thru 215TC Applications: Conveyors, Pumps and other equipment in food processing and severe environments where motors are washed on a regular basis. Features: Includes all the advantages of our standard Paint Free washdown duty motors. Specifically designed and built for use on adjustable speed drives. For adjustable speed applications not requiring full torque at zero speed. Not encoder adaptable. 20:1 Constant Torque Speed Range Type C Dimension C-Face with Base 1/ C IDCSWDM E2 3516M F 0.8 3/ C IDCSWDM E2 3524M F /2 1 1/2 2 2 Volt Code C IDCSWDM E2 3524M E TC IDCSWDM3546T 1148 E2 3524M E C IDCSWDM E2 3528M F TC IDCSWDM3554T 1228 E2 3528M F C IDCSWDM E2 3535M F TC IDCSWDM3558T 1311 E2 3535M F TC IDCSWDM3611T 1438 E2 3628M F TC IDCSWDM3615T 1674 E2 3640M F / TC IDCSWDM3710T 2536 E2 3740M F TC IDCSWDM3714T 2899 E2 3750M F 13.0 C-Face less Base 1/ C IDVSWDM E2 3516M F 0.8 3/ C IDVSWDM E2 3524M F /2 1 1/ C IDVSWDM E2 3524M E TC IDVSWDM3546T 1142 E2 3524M E C IDVSWDM E2 3528M F TC IDVSWDM3554T 1221 E2 3528M F C IDVSWDM E2 3535M F TC IDVSWDM3558T 1300 E2 3535M F TC IDVSWDM3611T 1426 E2 3628M F TC IDVSWDM3615T 1663 E2 3640M F 6.5 Amps Servo DC 162

163 Three Phase - Inverter, Explosion Proof - TEFC, Class I, Group D 60 Hz. Max. NOTE: 60 Hz: E = /460 volts, F = 230/460. (1) Horizontal mount, rigid base (non c-face). 6 Class I, Group D only,t2b. 8 Class I, Group D; Class II, Group F and G, T3C. Inverter Drive /Vector Drive & Controls 1/2 thru 75 56C thru 405T Applications: Designed for use in hazardous locations with Inverters. Features: UL and CSA approved for hazardous locations. 1/2 through 2 Class I, Group D, Class II, Groups F & G, Temperature Code T3C (160 C). 3 and larger, Class I, Group D only, Temperature Code T2B (280 C). Class F insulation, ISR (Inverter Spike Resistant) magnet wire, 1.0 service factor, thermostats. All ratings constant horsepower 60 to 90 Hz. Not encoder adaptable. Type C Dimension 2:1 Constant Torque, 10:1 Variable Torque Ratings TC IDXM7142T E2 X0628M F TC IDXM7144T E2 X0640M F / TC IDXM7147T E2 X0734M F TC IDXM7170T E2 X0750M E TC IDXM7054T E2 X0942M F TC IDXM7056T E2 X0952M F T IDXM7058T E2 X1050M F T IDXM7060T E2 X1056M F T IDXM7062T E2 X1260M F T IDXM7064T E2 X1266M F T IDXM7066T E2 X1462M F T IDXM7068T (1) E2 X1666M F :1 Constant Torque and Variable Torque Ratings 1/ C IDXM E2 X3516M F 0.8 3/ C IDXM E2 X3520M F TC IDXM7014T E2 X3524M F / TC IDXM7034T E2 X3528M F TC IDXM7037T E2 X3540M F TC IDXM7542T E2 X0628M F TC IDXM7544T E2 X0729M F / TC IDXM7547T E2 X0734M F TC IDXM7570T E2 X0948M F TC IDXM7554T E2 X0948M F T IDXM7556T E2 X1044M F T IDXM7558T E2 X1246M F T IDXM7560T E2 X1256M F T IDXM7562T E2 X1452M F T IDXM7564T E2 X1458M F T IDXM7566T E2 X1666M F 69.0 Volt Code Amps SHADED RATINGS ARE CAST IRON FRAMES HVAC Farm Duty Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz Inverter/Vector & Controls Servo DC 163

164 HVAC Farm Duty Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz Inverter/Vector & Controls Servo DC 164 Three Phase - Vector - TEBC and TENV, C-Face /2 1 1/2 1 1/2 1 1/ /2 7 1/2 7 1/2 7 1/ Hz. Max. Inverter Drive /Vector Drive & Controls 1 thru C thru 447T Applications: Test stands, material handling, packaging equipment, printing presses, etc. Features: Applications requiring adjustable speed operation with full torque from zero to base speed and constant horsepower to maximum speed. Includes HS25 or HS35 encoder feedback with MS connector. Meets MG1, part 31. Torque at Zero Speed, 1000:1 Constant Torque Speed Range,1024 Line Count Encoder NOTE: 60 Hz: F = 230/460, H = 575. See notes on pages 8 and 9, and inside back flap. Constant velocity fan: 115 volts, single phase from 143TC through 184TC and all 575 volt drive motors. Constant velocity fan: 230/460, three phase from 213TC through 447T. 284T-447T motors are horizontal mount, no C-Face. May be converted to C-Face in Mod Express or built as custom motors. Type C Dimension Volt Code Amps TC ZDNM3581T 1810 E2 0524M F TC ZDM3581T 2074 E2 0524M F TC ZDM3581T E2 0524M H TC ZDM3582T 2265 E2 0528M F TC ZDNM3584T 1894 E2 0532M F TC ZDM3584T 2137 E2 0528M F TC ZDM3584T E2 0528M H TC ZDM3667T 2426 E2 0632M F TC ZDNM3669T 1936 E2 0628M F TC ZDM3587T 2218 E2 0535M F TC ZDM3587T E2 0535M H TC ZDM3664T 2466 E2 0640M F TC ZDNM3661T 2078 E2 0634M F TC ZDM3661T 2561 E2 0628M F TC ZDM3661T E2 0628M H TC ZDM3764T 2923 E2 0730M F TC ZDNM3767T 2222 E2 0734M F TC ZDM3665T 2654 E2 0640M F TC ZDM3665T E2 0640M H TC ZDM3768T 3358 E2 0740M F TC ZDNM2237T 2596 E2 0932M F TC ZDM3770T 2942 E2 0730M F TC ZDM3770T E2 0734M H TC ZDM2276T 4400 E2 0954M F TC ZDNM2238T 2745 E2 0948M F TC ZDM3774T 3005 E2 0750M F TC ZDM3774T E2 0750M H TC ZDM2332T 4812 E2 0960M F TC ZDNM2333T 2994 E2 0948M F TC ZDM2333T 3329 E2 0936M F TC ZDM2333T E2 0936M H T ZDM4100T 5933 E2 1054M F T ZDNM2334T 3863 E2 1056M F TC ZDM2334T 3490 E2 0948M F TC ZDM2334T E2 0948M H T ZDM4102T 6556 E2 1060M F T ZDM4103T 3495 E2 1046M F T ZDM4111T 6701 E2 1248M F T ZDM4104T 3953 E2 1056M F T ZDM4117T 7418 E2 1254M F 38.0 SHADED RATINGS ARE CAST IRON FRAMES

165 Inverter Drive /Vector Drive & Controls Three Phase - Vector - TEBC and TENV, C-Face continued Torque at Zero Speed 1000:1 Constant Torque Speed Range 1024 Line Count Encoder Hz. Max T ZDM4410T E2 1868M G T ZDM4406T E2 1888M G T ZDM4407T E M G NOTE: 60 Hz: F= 230/460, G= 460. Consult District Office for availability of 2 pole motors. SHADED RATINGS ARE CAST IRON FRAMES Constant velocity fan: 115 volts, single phase from 143TC through 184TC and all 575 volt drive motors. Constant velocity fan: 230/460, three phase from 213TC through 447T. 284T-447T motors are horizontal mount, no C-Face. May be converted to C-Face in Mod Express or built as custom motors. See notes on pages 8 and 9, and inside back flap. Type C Dimension Volt Code Amps T ZDM4110T 5143 E2 1256M F T ZDM4308T 8423 E2 1464M F T ZDM4115T 5731 E2 1262M F T ZDM4312T E2 1474M F T ZDM4314T 6500 E2 1462M F T ZDM4403T E2 1662M F T ZDM4316T 7524 E2 1482M F T ZDM4404T E2 1680M F T ZDM4400T E2 1684M G T ZDM4409T E2 1888M G HVAC Farm Duty Definite Purpose Brake 200 & 575 Volt Three Phase - Vector, Washdown - TENV, C-Face with Base 60 Hz. Max. 1 thru TC thru 254TC Applications: Material handling, packaging equipment in food processing and other wet environments. Features: Designed for inverter or vector applications where up to a 1000:1 constant torque speed range is required. include HS25 encoder feedback mounting with MS connector. Meets MG1, Part 31. Includes 1024 Line Count Encoder TC ZDWNM3546T 1957 E2 3524M F / TC ZDWNM3554T 2056 E2 3535M F TC ZDWNM3609T 2166 E2 3628M F TC ZDWNM3611T 2273 E2 3634M F TC ZDWNM3707T 2443 E2 3735M F / TC ZDWNM22937T 3246 E2 3940M F TC ZDWNM22938T 3634 E2 3956M F 12.0 NOTE: 60 Hz: F= 230/460. See notes on pages 8 and 9, and inside back flap. Type C Dimension Volt Code Amps IEC 50 Hertz Inverter/Vector & Controls Servo DC 165

166 HVAC Farm Duty Definite Purpose Brake 200 & 575 Volt IEC Three Phase - Vector, Elevator Duty - ODP 60 Hz. Max. Inverter Drive /Vector Drive & Controls Includes 1024 Line Count Encoder 10 thru T thru 405T Applications: Elevator modernizations where a premium efficient, quiet, high torque motor is required. Features: Cast iron frame and endplates, electrically isolated 1024 PPR HS35 optical encoder with connector, inverter spike resistant magnet wire, Class H insulation, 50 C rise, 320% minimum breakdown torque, winding thermostat, 1/8 shaft endplay. Complies with MG1, Part T ZDME2511T-CI 3505 E2 0944M F T ZDME2524T-CI 4118 E2 1044M F T ZDME2528T-CI 4651 E2 1050M F T ZDME2532T-CI 5584 E2 1248M F T ZDME2536T-CI 5687 E2 1256M F T ZDME2540T-CI 6280 E2 1450M F T ZDME2544T-CI 6923 E2 1458M F T ZDME2548T-CI 8746 E2 1660M G T ZDME2552T-CI 9526 E2 1672M G 90.0 NOTE: 60 Hz: F= 230/460, G= 460. See notes on pages 8 and 9, and inside back flap. SHADED RATINGS ARE CAST IRON FRAMES Constant Velocity Blower Cooling Conversion Kits Type C Dimension Volt Code Amps 143TC thru 447TC 50 Hertz These kits convert TENV or TEFC AC motors to a Totally Enclosed Blower Cooled (TEBC) design. This is advantageous where continuous cooling is required regardless of motor shaft speed. These kits can be mounted on the back of the motor after removing the fan guard and fan. Removing the TEFC fan shaft is not required. Inverter/Vector & Controls Servo DC Voltage /380/ /380/ /380/ /380/ /380/ /380/ /380/460 Phase TC-145TC 182TC-184TC 213TC-215TC 254TC-256TC 284TC-286TC 324TC-326TC 364TC-365TC 213TC-215TC 254TC-256TC 284TC-286TC 324TC-326TC 364TC-365TC 404TC-405TC 444TC-447TC BLWL05-L BLWL06-L BLWL07-L BLWL09-L BLWL10-L BLWL12-L BLWL14-L BLWM07-F BLWM09-F BLWM10-F BLWM12-F BLWM14-F BLWM16-F BLWM18-F E8 E8 E8 E8 E8 E8 E8 E8 E8 E8 E8 E8 E8 E

167 Feedback Cable Assembly with MS Connector Inverter Drive /Vector Drive & Controls For the convenience of our customers, we offer a connector plug/cable assembly for Vector and DC motors. This assembly provides the connection from the encoder to the control. The twisted pair shielded cable provides additional noise protection. The assembly decreases installation time and effort. Recommended for Vector Drive and DC applications. HVAC Farm Duty Encoder Feedback Kits Cable Extension Length CBL015ZD-2 5 Ft = 1.5 Meters 134 E8 1 CBL030ZD-2 10 Ft = 3 Meters 156 E8 2 CBL046ZD-2 15 Ft = 4.6 Meters 178 E8 2 CBL061ZD-2 20 Ft = 6.1 Meters 198 E8 2 CBL091ZD-2 30 Ft = 9.1 Meters 241 E8 3 CBL152ZD-2 50 Ft = 15.2 Meters 326 E8 6 CBL229ZD-2 75 Ft = 22.9 Meters 431 E8 8 CBL305ZD Ft = 30.5 Meters 537 E8 12 CBL379ZD Ft = 37.9 Meters 644 E8 14 CBL455ZD Ft = 45.5 Meters 700 E8 15 CBL606ZD Ft = 60.6 Meters 962 E8 16 Ap x Definite Purpose Brake 200 & 575 Volt ENC00NV-B1 ENC02BC-B2 Optical encoders and magnetic pulse generators feature 1024 pulses per revolution, MS connector, and all hardware required to mount to our Inverter Drive. Several brands of encoders are available; BEI, Dynapar, Northstar (LakeShore), and Avtron. All brands feature similar through-shaft mounting. See Mod Express section for information on factory installation. If older style encoders with couplings are preferred, these may be added through Mod Express or built as custom motors. IEC 50 Hertz Type Enclosure Description Magnetic or Optical Input Voltage ENC00NV-A1 TENV M4 Avtron Magnetic 5-24 VDC 213T-215T 2315 E8 4 ENC00NV-B1 TENV HS25 BEI Optical 5-15 VDC T 969 E8 2 ENC00NV-D1 TENV HS35 Dynapar Optical 5-24 VDC T 1116 E8 4 ENC00NV-N1 TENV HS35 Northstar Magnetic 5-24 VDC T 1116 E8 4 ENC01BC-B1 TEBC HS25 BEI Optical 5-15 VDC 143T-215T 969 E8 3 ENC01BC-D1 TEBC HS35 Dynapar Optical 5-24 VDC T 1116 E8 4 ENC01NV-A1 TENV M4 Avtron Magnetic 5-24 VDC 254T-256T 2315 E8 4 ENC01NV-B2 TENV HS35 BEI Optical 5-15 VDC 254T-284T 969 E8 4 ENC01NV-D1 TENV HS35 Dynapar Optical 5-24 VDC 254T-256T 1116 E8 4 ENC01NV-N1 TENV HS35 Northstar Magnetic 5-24 VDC 254T-256T 1116 E8 4 ENC02BC-A1 TEBC M4 Avtron Magnetic 5-24 VDC 254T-447T 2315 E8 4 ENC02BC-B2 TEBC HS35 BEI Optical 5-15 VDC 254T-447T 969 E8 2 ENC02BC-D1 TEBC HS35 Dynapar Optical 5-24 VDC 254T-447T 1116 E8 4 ENC02BC-N1 TEBC HS35 Northstar Magnetic 5-24 VDC 254T-447T 1116 E8 4 Inverter/Vector & Controls Servo DC 167

168 HVAC Farm Duty Series 15J Mini Inverters Inverter Drive /Vector Drive & Controls 1/3 thru VAC 1 Phase - 60 Hz 1 thru VAC 3 Phase - 50/60 Hz 1 thru VAC 3 Phase - 50/60 Hz Applications: Variable torque, constant torque or constant horsepower applications. New installations, replacements and original equipment manufacturers (OEM). Definite Purpose Brake 200 & 575 Volt Design Specifications Dual microprocessor controlled PWM output Free run or ramp stop Controlled reversing Selectable preset speeds Dynamic braking option DC injection braking Analog meter output Relay contact output Two analog inputs Process control (PID) Max output frequency of 150 Hz Control Specification Control Method PWM Frequency Features: 1 enclosure as standard. Output frequency 0.25 to 150 Hz with peak overload capacity of 200%. Separate accel/decel rates and controlled reversing. Digital operator control and display. Operator Keypad Digital speed control Forward/Reverse command Stop command Jog command Parameter setting and display Display 2 lines by 16 character in English, Spanish, French, German, Italian, and Portuguese Membrane keys with tactile feel Optional remote mount 4X keypad Sinewave carrier input, PWM output Rated at 2.5 khz - adjustable khz Environmental and Protective Features Operating Conditions Selectable automatic restart at Input voltage momentary power loss 1 Phase VAC ±10%. DC bus and fault indicator 3 phase VAC ±10%, Adjustable time based overload 3 phase VAC ±10%, Cause of last 31 trips retained Input frequency - in memory 50 or 60 Hz ±10% Digital display for fault conditions Service factor Isolated control circuitry Duty - continuous Humidity - 90% max non-condensing Altitude feet max without derate IEC 50 Hertz Inverter/Vector & Controls Servo Protective Functions Ambient Conditions V/Hz Ratio Torque Boost Brake Torque Frequency Setting Accel/Decel Inverter Trip External Output Short Circuit Temperature Cooling Linear to squared reduced 0-15% - adjustable Up to 60%, external resistor required 0-5 VDC, 0-10 VDC, 0-20 ma, 4-20mA, digital via keypad Separate accel/decel rates, seconds Over voltage, over current, under voltage, external trip, heatsink thermal, motor overload NO and NC relay and LED indicator for trip Output phase to ground and phase to phase 0-40 C, derate for up to 55 C Forced air included when required Dimensions Outside 7.60 (193) Height 4.83 (123) Width 4.45 (113) Depth (5.2(132) depth for ID15J205-ER and ID15J407-ER) Mounting 7.21 (183) Height 4.40 (112) Width DC 168

169 Series 15J Mini Inverters continued Inverter Drive /Vector Drive & Controls HVAC kw Input Output Current Volt Cont. 60 Sec 2 Sec (1) ID15J1F33-ER 634 E (1) ID15J1F50-ER 652 E (1) ID15J1F75-ER 671 E (1) ID15J101-ER 706 E ID15J201-ER 683 E ID15J201F5-ER 743 E ID15J202-ER 795 E ID15J203-ER 983 E ID15J205-ER 1104 E ID15J401-ER 952 E ID15J401F5-ER 1024 E ID15J402-ER 1174 E ID15J403-ER 1275 E ID15J405-ER 1435 E ID15J407-ER 1851 E1 NOTE: (1)115 volt, 1 phase input; 230 volt, 3 phase output. Farm Duty Definite Purpose Brake Dynamic Braking Assemblies Aluminum frame resistors Panel mounting tabs Input Volts Min. Ohms Continuous Rated Watts or RGJ160 RGJ260 RGJ360 Muit. 200 & 575 Volt RGJ1150 RGJ2150 RGJ RGJ1120 RGJ2120 RGJ E8 IEC Inverter/Vector & Controls Servo DC 50 Hertz Keypad with Cable 32 Character alphanumeric display 4X enclosure when mounted on panel Backlit LCD Remote mount to 100 ft. from control Cable Length CBLSM015KP 5 ft. 202 E8 CBLSM030KP 10 ft. 232 E8 CBLSM046KP 15 ft. 260 E8 CBLSM061KP 20 ft. 288 E8 CBLSM091KP 30 ft. 345 E8 CBLSM152KP 50 ft. 458 E8 CBLSM229KP 75 ft. 572 E8 CBLSM305KP 100 ft. 743 E8 169

170 HVAC Farm Duty Series 15P Mini Inverter Inverter Drive /Vector Drive & Controls 1/3 thru VAC 1 Phase - 60 Hz 1 thru VAC 3 Phase - 50/60 Hz 1 thru VAC 3 Phase - 50/60 Hz Applications: Variable torque, constant torque or constant horsepower applications. New installations, replacements and original equipment manufacturers (OEM). Definite Purpose Brake 200 & 575 Volt Design Specifications Dual microprocessor controlled PWM output Free run or ramp stop Controlled reversing Dynamic braking option Adjustable torque boost Separate accel/decel rates Selectable auto restart Adjustable current limit Max output frequency of 130 Hz Features: 1 enclosure as standard. Output frequency 0.25 to 150 Hz with peak overload capacity of 200%. Separate accel/decel rates and controlled reversing. Rotary speed control with direction indicators. Operator Keypad Rotary speed control Forward/Reverse command Stop command Membrane keys with tactile feel Fault indicator Power on indicator Environmental and Operating Conditions Input voltage 1 Phase VAC ±10%. 3 phase VAC±10%, 3 phase VAC ±10%, Input frequency - 50 or 60 Hz ±10% Service factor Duty - continuous Humidity - 90% max non-condensing Altitude feet max without derate Protective Features Selectable automatic restart at momentary power loss DC bus present indicator Fault indicator Adjustable time based overload Isolated control circuitry IEC 50 Hertz Inverter/Vector & Controls Control Control Method Sinewave carrier input, PWM output Specification PWM Frequency Rated at 2.5 khz V/Hz Ratio Linear with adjustable torque boost Torque Boost 0-15% - adjustable Brake Torque Up to 60%, external resistor required Frequency Setting 0-10 VDC, 4-20mA, digital via keypad Accel/Decel Separate accel/decel rates, 0-60 seconds Protective Inverter Trip Over voltage, over current, under voltage, external trip, heatsink thermal, motor overload Functions External Indicators Separate LED indicators for fault trip and power ON Short Circuit Output phase to ground and phase to phase Ambient Temperature 0-40 C, derate for up to 55 C Conditions Cooling Forced air included when required Dimensions Outside 7.60 (193) Height 4.83 (123) Width 4.45 (113) Depth [5.2(132) depth for ID15P205-ER and ID15P407-ER] Mounting 7.21 (183) Height 4.40 (112) Width Servo DC 170

171 Series 15P Mini Inverters continued Inverter Drive /Vector Drive & Controls HVAC kw Input Volt Output Current Cont. 60 Sec. 2 Sec (1) ID15P1F33-ER 628 E (1) ID15P1F50-ER 646 E (1) ID15P1F75-ER 664 E (1) ID15P101-ER 705 E ID15P201-ER 681 E ID15P201F5-ER 739 E ID15P202-ER 791 E ID15P203-ER 930 E ID15P205-ER 1058 E ID15P401-ER 896 E ID15P401F5-ER 977 E ID15P402-ER 1128 E ID15P403-ER 1233 E ID15P405-ER 1395 E ID15P407-ER 1791 E1 Farm Duty Definite Purpose Brake NOTE: (1) 115 volt, 1 phase input; 230 volt, 3 phase output. Dynamic Braking Assemblies Aluminum frame resistors Panel mounting tabs Input Volts 115 or 230 Min. Ohms Continuous Rated Watts RGJ160 RGJ260 RGJ RGJ1150 RGJ2150 RGJ RGJ1120 RGJ2120 RGJ & 575 Volt IEC E8 DC Servo Inverter/Vector & Controls 50 Hertz 171

172 HVAC Farm Duty Series 5 Micro Inverters Inverter Drive /Vector Drive & Controls 1/2 thru VAC 1 Phase - 50/60 Hz 1/2 thru VAC 1 Phase - 50/60 Hz 2 thru VAC 3 Phase - 50/60 Hz 1 thru VAC 3 Phase - 50/60 Hz Applications: Variable torque, constant torque or constant horsepower applications. New installations, replacements and original equipment manufacturers (OEM). Definite Purpose Brake 200 & 575 Volt Design Specifications PWM output Accel/decel rate adjustment Controlled reversing Adjustable current limit I 2 t motor overload protection Adjustable slip compensation Min/max output frequency adjustment Selectable auto/manual restart Features: 4 or open chassis mount standard. Output frequency 0.25 to 120 Hz with peak overload capacity of 150%. Separate accel/decel rates and controlled reversing. Operator Interface- Enclosed Units Start/Stop command 4X enclosure Power on/off Rotary speed control Fwd/Rev optional Auto/Manual optional Environmental and Operating Conditions Input voltage: 1 phase 115 VAC ±15%, 1 phase 230 VAC ±15% 3 phase 230V ±15% 3 phase 460 ± 15% Input frequency 50 or 60Hz ±10% Service factor Duty - continuous Humidity - 90% max RH non-condensing Altitude feet max without derate Protective Features Selectable automatic restart at momentary power loss Power indicator Status indicator Adjustable time base overload Electronic in rush current limiting IEC 50 Hertz Inverter/Vector & Controls Servo Output Ratings Control Spec Protective Functions Ambient Conditions Overload Capacity 150% for 120 seconds Voltage - 3 Phase VAC (RMS), V AC (RMS) Control Method Sinewave carrier input, PWM output PWM Frequency Rated 8.0 khz V/Hz Ratio Factory set for optimum output Torque Boost Factory set for 60 Hz motors. Adjustable 6-30% for 50 Hz motors Adjustable 0-30% max Current Limit Adjustable 63 to 188% of rated output 0-200% Frequency Setting 0-5 VDC, 0-10 VDC with external resistor network, non-isolated input Accel/Decel Separate accel/decel rates, sec for 60 Hz motors Sec Combined accel/decel for 50 Hz motors Inverter Trip Over voltage, over current, under voltage, motor overload, output short circuit Status Indicators Tricolor LED indicator for status and green LED indicator for power on Short Circuit Output phase to phase Temperature 0-45 C 0-50 C Cooling Convection 1/2-2 ; Forced Air 3-5 Convection Enclosure Open chassis 4X (IP65) DC 172

173 Series 5 Micro Inverters continued Inverter Drive /Vector Drive & Controls HVAC /kw Input Volt Output Dimensions in/(mm) Current Outside Mounting Cont. 120 Sec. H W D H W Open Chassis Mount Single Phase Input 0.5/ / ID56F50-CO 316 E / / ID5601-CO 383 E / / ID5602-CO 498 E Open Chassis Mount Three Phase Input 2/1.5 2/ ID5202-CO 603 E / ID5203-CO 635 E / ID5401-CO 657 E / ID5402-CO 674 E / ID5403-CO 693 E / ID5405-CO 885 E X Enclosed Single Phase Input 1/ / ID5601-WO 611 E / / ID5601-BO 573 E / / / /10.0 ID5602-WO 862 E / / / /10.0 ID5602-BO 814 E X Enclosed Three Phase Input 3/ ID5203-WO 977 E / ID5203-BO 929 E / ID5403-WO 1034 E / ID5403-BO 986 E / ID5405-WO 1101 E / ID5405-BO 1053 E NOTE: -WO is white in color -BO is black in color 1 Jumper configurable for 1 HP and 2 HP Red catalog number = New item Farm Duty Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz ID5RGA-1 ID5SI-1 Description Dynamic braking kit for open chassis 115/230V 1/2 and 1 rated controls Signal isolator for open chassis units Provides isolation for up to 24 VDC and 4-20mA command signals 195 E E9 4 Inverter/Vector & Controls ID5SI-2 ID5AMS-1 Signal isolator for 4X enclosed units Provides isolation for up to 24 VDC and 4-20mA command signals and run relay output. Select relay as N.O. or N.C. contacts rated at A. Auto/Manual selection switch for 4X enclosed units Allows selection of remote or on-board speed commands 192 E E9 1 Servo ID5FRS-1 Forward/Stop/Reverse selection switch for 4X enclosed units Allows selection of forward or reverse motor direction commands 26 E9 1 DC 173

174 HVAC Farm Duty Definite Purpose Smart Adjustable Speed Integrated /Drive 230 and 460 Volts Inverter Drive /Vector Drive & Controls 1 thru 10 56C thru 215TC Applications: Variable torque, constant torque or constant horsepower applications. New installations, replacements and original equipment manufacturers (OEM). Features: TEFC matched motor and control. 1 enclosure on CSM and JMSM designs. 4X enclosure on CWDSM designs. Output speeds to 2X base speed and overload capacity of 150%. standard motor frames with premium efficiency motor designs. Brake 200 & 575 Volt Design Specifications Dual microprocessor controlled PWM output Free run or ramp stop Controlled reversing Selectable preset speeds Dynamic braking option DC injection braking Analog meter output One digital output One analog Input Process control (PID) Profile Run Operator Keypad Optional Remote Mount Keypad Digital speed control Forward/Reverse command Stop command Jog command Parameter setting and display Display 2 lines by 16 character Membrane keys with tactile feel Environmental and Protective Features Operating Conditions Selectable automatic restart at Input voltage momentary power loss 3 phase VAC±10%, DC bus and fault indicator 3 phase VAC ±10%, Adjustable time based overload Input frequency - Cause of last 31 trips retained 50 or 60 Hz ±10% in memory Service factor Digital display for fault conditions Duty - continuous Isolated control circuitry Humidity - 90% max non-condensing Altitude feet max without derate IEC 50 Hertz Inverter/Vector & Controls Servo DC Output Ratings Input Ratings Control Spec Protective Functions LCD Display (optional) Ambient Conditions Overload Capacity 150% for 60 seconds Speed Range 180 to 3600 maximum; variable or constant torque for 3450 base speed 180 to 1800 variable torque, constant torque max, 1800 to 3600 constant hp for 1750 base Horsepower Base speed ratings at 230 VAC or 460 VAC Frequency 50 or 60 Hz ± 5% Voltage VAC ±10%; VAC ± 10% Phase Three phase or single phase with derate. No single phase derate required for 1 and 2 horsepower Impedance 1% minimum required Control Method Sinusoidal PWM PWM Frequency Adjustable 2.2 to 18 khz (1-3 ); 2.2 to 9 khz (5-10 ) V/Hz Ratio Factory tuned to motor, minimum frequency limit, maximum frequency limit (120Hz) Torque Boost 0-15% of input voltage; automatic with manual override Brake Torque 20% standard on CSM and CWDSM catalog numbers (optional on JMSM) Skip Frequency Three zones 0-max frequency Speed Setting 0-5 VDC, 0-10 VDC, 0-20mA, 4-20mA Accel/Decel Separate accel/decel rates, sec. to maximum frequency External Output 1 assignable digital output and LED indicator for trip Trip Over voltage, over current, under voltage, external trip, heatsink thermal, motor overload Stall Prevention Over voltage suppression, overcurrent suppression Running Output frequency, set frequency, output current, voltage,, custom units Setting Parameter values for setup and review Trip Separate message for each trip, cause of last 31 trips retained in memory Temperature C ambient Cooling Fan cooled 174

175 Smart and 460 Volts Base Speed Base 60 Hz. Inverter Drive /Vector Drive & Controls (1) NOTE: (1) Without optional keypad. See notes on pages 8 and 9, and inside back flap. Constant Torque Speed Range Type C Dimension 230 Volts C CSM E DV3524M TC CSM3546T E DV3524M TC CSM3558T E DV3540M TC CSM3611T E DV3628M TC CSM3615T E DV3646M / TC CSM3710T E DV3734M TC CSM3714T E DV3746M Volts C CSM E DV3524M TC CSM3546T E DV3524M TC CSM3558T E DV3540M TC CSM3611T E DV3628M TC CSM3615T E DV3646M / TC CSM3710T E DV3734M TC CSM3714T E DV3746M Min. Max. Size HVAC Farm Duty Definite Purpose Brake Washdown Smart - TEFC, 230 and 460 Base Speed Base 60 Hz. (1) NOTE: (1) Without optional keypad. See notes on pages 8 and 9, and inside back flap. Constant Torque Speed Range Type C Dimension 230 Volts C CWDSM E DV3524M TC CWDSM3546T E DV3524M TC CWDSM3558T E DV3540M TC CWDSM3611T E DV3628M TC CWDSM3615T E DV3646M / TC CWDSM3710T E DV3734M TC CWDSM3714T E DV3746M Volts C CWDSM E DV3524M TC CWDSM3546T E DV3524M TC CWDSM3558T E DV3540M TC CWDSM3611T E DV3628M TC CWDSM3615T E DV3646M / TC CWDSM3710T E DV3734M TC CWDSM3714T E DV3746M Min. Max. Size 200 & 575 Volt IEC 50 Hertz Inverter/Vector & Controls Servo DC 175

176 HVAC Farm Duty Definite Purpose Brake 200 & 575 Volt IEC Inverter Drive /Vector Drive & Controls Close-Coupled Pump Smart -TEFC, 230 and 460 Volts Base Speed Base 60 Hz. NOTE: (1) Without optional keypad. See notes on pages 8 and 9, and inside back flap. Smart Keypad with Cable 32 Character English alphanumeric display when mounted on panel Backlit LCD Remote mount to 100 ft. from control (1) Constant Torque Speed Range Type C Dimension 230 Volts JM JMSM3545T E DV3516M JM JMSM3555T E DV3532M JM JMSM3610T E DV3628M JM JMSM3613T E DV3634M / JM JMSM3709T E DV3733M JM JMSM3711T E DV3738M Volts JM JMSM3545T E DV3516M JM JMSM3555T E DV3532M JM JMSM3610T E DV3628M JM JMSM3613T E DV3634M / JM JMSM3709T E DV3733M JM JMSM3711T E DV3738M Min. Max. Cable Length Size CBLSM015KP 5 ft. 202 E8 1 CBLSM030KP 10 ft. 232 E8 1 CBLSM046KP 15 ft. 260 E8 1 CBLSM061KP 20 ft. 288 E8 1 CBLSM091KP 30 ft. 345 E8 1 CBLSM152KP 50 ft. 458 E8 1 CBLSM229KP 75 ft. 572 E8 1 CBLSM305KP 100 ft. 743 E8 1 CBLSM015KP-W (2) 5 ft. 202 E8 4X CBLSM046KP-W (2) 15 ft. 260 E8 4X CBLSM091KP-W (2) 30 ft. 345 E8 4X NOTE: (2) Keypad is white in color Enclosure Rating 50 Hertz Inverter/Vector & Controls Servo DC Smart Keypad Mounted Covers 32 Character English alphanumeric display Backlit LCD Keypad mounted to terminal cover Includes connecting cable Smart Cover with Keypad Jack Keypad Jack mounted to cover Removable dust cover Order keypad with cable (above) NOTE: (2) Keypad is white in color Type No. Enclosure Rating CVRSM35KP-B 249 E8 DV35 1 CVRSM36KP-B 256 E8 DV36 1 CVRSM37KP-B 263 E8 DV37 1 CVRSM35KP-W (2) 249 E8 DV35 4X CVRSM36KP-W (2) 249 E8 DV36 4X Type No. Enclosure Type CVRSM35KJ-B 49 E8 DV35 1 CVRSM36KJ-B 60 E8 DV36 1 CVRSM37KJ-B 71 E8 DV

177 Dimensions Inverter Drive /Vector Drive & Controls DC HVAC Brake 200 & 575 Volt IEC 50 Hertz Inverter/Vector & Controls Servo Definite Purpose Farm Duty Dimension Model 2F C D E O P U V AH AJ AK BA BB BD BF CO1 CO2 CO3 CO4 LB WB 56C TC JM TC JM TC JM TC JM TC JM TC JM NOTE: Drawings shown are for reference only. Drawings are available from our CD-ROM or web site at Dimensions (JM Series Shaft) JM Model EQ EM EL AH U

178 HVAC Farm Duty H2 Inverter/ Encoderless Vector Inverter Drive /Vector Drive & Controls 3/4 thru 3 115/230 VAC 1 Phase - 50/60 Hz 1 thru VAC 3 Phase - 50/60 Hz 1 thru VAC 3 Phase - 50/60 Hz 1 thru VAC 3 Phase - 60 Hz Applications: Constant torque, variable torque or constant horsepower applications. New installations, replacements and original equipment manufacturers (OEM). Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz Inverter/Vector & Controls Servo DC 178 Design Specifications Process follow +5VDC 0-5 VDC, +10VDC, 0-10 VDC, 0-20mA, 4-20mA, digital via keypad or serial Linear or S-curve deceleration 2 assignable analog outputs 2 assignable opto outputs 2 assignable relay outputs 2 assignable analog inputs Auto tuning to motor Adaptive tuning to load USB 2.0 full speed port ModBus RTU port Output Ratings Input Ratings Control Spec Protective Functions Keypad Display Ambient Conditions Features: 1 enclosure as standard. Output frequency 0 to 500 Hz with peak overload capacity of 175%. Separate accel/decel rates and controlled reversing. Built in two and three input PID process control loop. Operator Keypad Forward/Reverse command RUN and JOG Local/Remote key Stop command Parameter setting and display 128x64 graphical display Remote mount to 200 feet (60m) from control 4X enclosure when mounted on panel Upload and download parameter sets Help text displays Environmental and Operating Conditions Input voltage 1 phase ± 10% 1 phase ± 10% 3 phase VAC ±10% 3 phase VAC ±10% 3 phase VAC ±10% Input frequency - 50 or 60Hz ±5% Service factor Duty - continuous Humidity - 90% max RH non-condensing Altitude feet (1000m) max without derate Overload Capacity 150% for 60 seconds; 175% for 3 seconds for constant torque 115% for 60 seconds for variable torque Frequency Hz standard Voltage 0-Maximum input voltage (RMS) Frequency 50 or 60 Hz ± 5% Voltage (VAC) Phase Single Phase Three phase (single phase with derate) Impedance 1% minimum from mains connection Control Method Sinewave carrier input, PWM output; selectable encoderless vector or V/Hz inverter PWM Frequency Adjustable 1-5 khz standard, 5-16 khz quiet V/Hz Ratio Linear to squared reduced, base frequency, output voltage, minimum frequency limit, maximum frequency limit Torque Boost 0-30% of input voltage; automatic with manual override Brake Torque 20% standard on Sizes AA and B, 1% standard on Size C Skip Frequency Three zones 0-Max frequency Frequency Setting ±5 VDC, 0-5 VDC, ±10 VDC, 0-10 VDC, 0-20mA, 4-20mA, digital via keypad, Serial Comms/USB 2.0 and ModBus RTU std. Accel/Decel Separate accel/decel rates, sec to maximum frequency, linear, S-curve, C-curve PC Setup Software Workbench Software available via connection to USB2.0 port for commissioning wizard, firmware download, parameter viewer, scope capture and cloning Inverter Trip Over voltage, over current, under voltage, external trip, heatsink thermal, motor overload Stall Prevention Over voltage suppression, overcurrent suppression External Output OPTO isolated outputs, relay outputs, and LED indicator for trip Short Circuit Phase to phase, phase to ground Running Output frequency, set frequency, output current(%), voltage,, custom units, power, energy consumed Setting Parameter values for setup and review Trip Separate message for each trip, cause of last 10 faults or alarms retained in memory Temperature -10 to + 45 C For UL ing Cooling Forced air OPTIONS: See page 193 for optional Expansion Boards including Ethernet, Isolated Input etc. See page 192 for optional Dynamic Braking Assemblies. Protective Features Adjustable current limit DC bus charge indicator Fault indicator Adjustable time based overload Cause of last 10 faults or alarms retained in memory Fault trace function Digital display for fault conditions with real time clock Linear heat sink thermal sensor Isolated control circuitry 24 VDC isolated user supply

179 Inverter Drive /Vector Drive & Controls H2 Inverter/Encoderless Vector - 115/230 and 230 Volts Constant Torque HVAC Volt Output Current Cont. Peak Output Ratings with 2.5 khz PWM Frequency - Single Phase Input 1 115/ IHH601-E * 971 E1 AA 2 115/ IHH602-E * 1104 E1 AA 3 115/ IHH603-E * 1290 E1 AA Output Ratings with 2.5 khz PWM Frequency - Three Phase Input IHH201-E 971 E1 AA IHH202-E 1104 E1 AA IHH203-E 1290 E1 AA IHH205-E 1485 E1 AA 7 1/ IHH207-E 1850 E1 AA IHH210-E 2602 E1 B IHH215-E 3400 E1 B IHH220-E 4201 E1 B IHH225-E 5624 E1 C IHH230-E 6454 E1 C IHH240-E 8597 E1 C IHH250-E ** E1 D IHH260-E ** E1 D Output Ratings with 8.0 khz PWM Frequency - "Quiet Drive " - Single Phase Input 3/4 115/ IHH601-E * 971 E1 AA 1 115/ IHH602-E * 1104 E1 AA 2 115/ IHH603-E * 1290 E1 AA Output Ratings with 8.0 khz PWM Frequency - "Quiet Drive " - Three Phase Input IHH201-E 971 E1 AA IHH203-E 1290 E1 AA IHH205-E 1485 E1 AA IHH207-E 1850 E1 AA 7 1/ IHH210-E 2602 E1 B IHH215-E 3400 E1 B IHH220-E 4201 E1 B IHH225-E 5624 E1 C IHH230-E 6454 E1 C IHH240-E 8597 E1 C IHH250-E ** E1 D IHH260-E ** E1 D OPTIONS: Dimensions are listed on page 184. See page 193 for optional Expansion Boards. See page 192 for optional Dynamic Braking Assemblies. See notes on pages 8 and 9, and inside back flap. * Single phase input voltage to control, three phase output voltage from control to motor. ** Available Q Red catalog number = New item Size Farm Duty Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz Inverter/Vector & Controls DC Servo 179

180 HVAC Farm Duty Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz Inverter/Vector & Controls Inverter Drive /Vector Drive & Controls H2 Inverter/Encoderless Vector - 115/230 and 230 Volts - Variable Torque Volt Output Current Cont. Peak Output Ratings with 2.5 khz PWM Frequency - Single Phase Input 2 115/ IHH601-E * 971 E1 AA 3 115/ IHH602-E * 1104 E1 AA Output Ratings with 2.5 khz PWM Frequency - Three Phase Input IHH201-E 971 E1 AA IHH202-E 1104 E1 AA IHH203-E 1290 E1 AA 7 1/ IHH205-E 1485 E1 AA IHH207-E 1850 E1 AA IHH210-E 2602 E1 B IHH215-E 3400 E1 B IHH225-E 5624 E1 C IHH230-E 6454 E1 C IHH240-E 8597 E1 C IHH250-E ** E1 D IHH260-E ** E1 D Output Ratings with 8.0 khz PWM Frequency - "Quiet Drive " - Single Phase Input 1 115/ IHH601-E * 971 E1 AA 2 115/ IHH602-E * 1104 E1 AA 3 115/ IHH603-E * 1290 E1 AA Output Ratings with 8.0 khz PWM Frequency - "Quiet Drive " - Three Phase Input IHH201-E 971 E1 AA IHH202-E 1104 E1 AA IHH203-E 1290 E1 AA IHH205-E 1485 E1 AA 7 1/ IHH207-E 1850 E1 AA IHH210-E 2602 E1 B IHH215-E 3400 E1 B IHH220-E 4201 E1 B IHH225-E 5624 E1 C IHH230-E 6454 E1 C IHH240-E 8597 E1 C IHH250-E ** E1 D IHH260-E ** E1 D OPTIONS: Dimensions are listed on page 184. See page 193 for optional Expansion Boards. See page 192 for optional Dynamic Braking Assemblies. See notes on pages 8 and 9, and inside back flap. * Single phase input voltage to control, three phase output voltage from control to motor. ** Available Q Red catalog number = New item Size Servo DC 180

181 Inverter Drive /Vector Drive & Controls H2 Inverter/Encoderless Vector Volts - Constant Torque HVAC Volt Output Current Cont. Peak Output Ratings with 2.5 khz PWM Frequency IHH401-E 1286 E1 AA IHH402-E 1478 E1 AA IHH403-E 1719 E1 AA IHH405-E 1929 E1 AA 7 1/ IHH407-E 2774 E1 AA IHH410-E 2946 E1 AA IHH415-E 3505 E1 B IHH420-E 4223 E1 B IHH425-E 5565 E1 B IHH430-E 6702 E1 C IHH440-E 7852 E1 C IHH450-E E1 C IHH460-E ** E1 D IHH475-E ** E1 D Output Ratings with 8.0 khz PWM Frequency - "Quiet Drive " 3/ IHH401-E 1286 E1 AA IHH402-E 1478 E1 AA IHH403-E 1719 E1 AA IHH405-E 1929 E1 AA IHH407-E 2774 E1 AA 7 1/ IHH410-E 2946 E1 AA IHH415-E 3505 E1 B IHH420-E 4223 E1 B IHH425-E 5565 E1 B IHH430-E 6702 E1 C IHH440-E 7852 E1 C IHH450-E E1 C IHH460-E ** E1 D IHH475-E ** E1 D OPTIONS: Dimensions are listed on page 184. See page 193 for optional Expansion Boards. See page 192 for optional Dynamic Braking Assemblies. See notes on pages 8 and 9, and inside back flap. ** Available Q Red catalog number = New item Size Farm Duty Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz DC Servo Inverter/Vector & Controls 181

182 HVAC Farm Duty Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz Inverter Drive /Vector Drive & Controls H2 Inverter/Encoderless Vector Volts - Variable Torque Volt Output Current Cont. Peak Output Ratings with 2.5 khz PWM Frequency IHH401-E 1286 E1 AA IHH402-E 1478 E1 AA IHH403-E 1719 E1 AA 7 1/ IHH405-E 1929 E1 AA IHH407-E 2774 E1 AA IHH410-E 2946 E1 AA IHH415-E 3505 E1 B IHH420-E 4223 E1 B IHH425-E 5565 E1 B IHH430-E 6702 E1 C IHH440-E 7852 E1 C IHH450-E E1 C IHH460-E ** E1 D IHH475-E ** E1 D Output Ratings with 8.0 khz PWM Frequency - "Quiet Drive " IHH401-E 1286 E1 AA IHH402-E 1478 E1 AA IHH403-E 1719 E1 AA IHH405-E 1929 E1 AA 7 1/ IHH407-E 2774 E1 AA IHH410-E 2946 E1 AA IHH415-E 3505 E1 B IHH420-E 4223 E1 B IHH425-E 5565 E1 B IHH430-E 6702 E1 C IHH440-E 7852 E1 C IHH450-E E1 C IHH460-E ** E1 D IHH475-E ** E1 D OPTIONS: Dimensions are listed on page 184. See page 193 for optional Expansion Boards. See page 192 for optional Dynamic Braking Assemblies. See notes on pages 8 and 9, and inside back flap. ** Available Q Red catalog number = New item Size Inverter/Vector & Controls Servo DC 182

183 Inverter Drive /Vector Drive & Controls H2 Inverter/Encoderless Vector Volts - Constant Torque Volt Output Current Cont. Peak Output Ratings with 2.5 khz PWM Frequency IHH501-E 1480 E1 AA IHH502-E 1701 E1 AA IHH503-E 1977 E1 AA IHH505-E 2219 E1 AA 7 1/ IHH507-E 3190 E1 AA IHH510-E 3396 E1 AA IHH515-E 4206 E1 B IHH520-E 5293 E1 B IHH525-E 6818 E1 B IHH530-E 7728 E1 C IHH540-E 9336 E1 C IHH550-E E1 C IHH560-E ** E1 D IHH575-E ** E1 D Output Ratings with 8.0 khz PWM Frequency - "Quiet Drive " 3/ IHH501-E 1480 E1 AA IHH502-E 1701 E1 AA IHH503-E 1977 E1 AA IHH505-E 2219 E1 AA IHH507-E 3190 E1 AA 7 1/ IHH510-E 3396 E1 AA IHH515-E 4206 E1 B IHH520-E 5293 E1 B IHH525-E 6818 E1 B IHH530-E 7728 E1 C IHH540-E 9336 E1 C IHH550-E E1 C IHH560-E ** E1 D IHH575-E ** E1 D OPTIONS: See page 193 for optional Expansion Boards. See page 192 for optional Dynamic Braking Assemblies. See notes on pages 8 and 9, and inside back flap. ** Available Q Red catalog number = New item Size HVAC Farm Duty Definite Purpose Brake 200 & 575 Volt IEC DC Servo Inverter/Vector & Controls 50 Hertz 183

184 HVAC Farm Duty Definite Purpose Brake 200 & 575 Volt IEC Inverter Drive /Vector Drive & Controls H2 Inverter/Encoderless Vector Volts - Variable Torque Volt Output Current Cont. Peak Output Ratings with 2.5 khz PWM Frequency OPTIONS: See page 193 for optional Expansion Boards. See page 192 for optional Dynamic Braking Assemblies. See notes on pages 8 and 9, and inside back flap. ** Available Q Red catalog number = New item IHH501-E 1480 E1 AA IHH502-E 1701 E1 AA IHH503-E 1977 E1 AA 7 1/ IHH505-E 2219 E1 AA IHH507-E 3190 E1 AA IHH510-E 3396 E1 AA IHH515-E 4206 E1 B IHH520-E 5293 E1 B IHH525-E 6818 E1 B IHH530-E 7728 E1 C IHH540-E 9336 E1 C IHH550-E E1 C IHH560-E ** E1 D IHH575-E ** E1 D Output Ratings with 8.0 khz PWM Frequency - "Quiet Drive " IHH501-E 1480 E1 AA IHH502-E 1701 E1 AA IHH503-E 1977 E1 AA IHH505-E 2219 E1 AA 7 1/ IHH507-E 3190 E1 AA IHH510-E 3396 E1 AA IHH515-E 4206 E1 B IHH520-E 5293 E1 B IHH525-E 6818 E1 B IHH530-E 7728 E1 C IHH540-E 9336 E1 C IHH550-E E1 C IHH560-E ** E1 D IHH575-E ** E1 D Size 50 Hertz Inverter/Vector & Controls Dimensions in/(mm) Size Outside Mounting Ap x Height Width Depth Height Width AA /(312) 7.974/(203) 8.21/(208) 11.75/(298) 7.38/(187) 20 B /(457) 9.100/(231) 9.75/(248) 17.25/(438) 7.00/(178) 30 C /(559) 9.100/(231) 9.75/(248) 21.25/(540) 7.00/(178) 60 D Available Q2 of 2006 Servo DC 184

185 H2 Vector Drive Inverter Drive /Vector Drive & Controls 1 thru 3 115/230 VAC 1 Phase - 50/60 Hz 3/4 thru VAC 3 Phase - 50/60 Hz 3/4 thru VAC 3 Phase - 50/60 Hz 3/4 thru VAC 3 Phase - 60 Hz Applications: Constant torque or constant horsepower applications. New installations, replacements and original equipment manufacturers (OEM). HVAC Farm Duty Design Specifications shaft orient to marker Process follow +5VDC 0-5 VDC, +10VDC 0-10 VDC,4-20mA, 0-20mA, digital via keypad or serial Linear or S-curve deceleration 2 assignable analog outputs 2 assignable opto outputs 2 assignable relay outputs 2 assignable analog inputs Auto tuning to motor Adaptive tuning to load USB 2.0 full speed port ModBus RTU port Output Ratings Input Ratings Control Spec Features: 1 enclosure as standard. Output frequency 0 to 500 Hz with peak overload capacity of 175%. Automatic tuning to motor and full rated torque down to zero speed. Digital speed or torque control. Built in two and three input PID process control loop. Operator Keypad Forward/Reverse command RUN and JOG Local/Remote key Parameter setting and display Stop command 128 x 64 Graphical Display Remote mount to 200 feet (60m) from control 4X enclosure when mounted on panel Upload and download parameter sets Help text displays Environmental and Operating Conditions Input voltage 1 phase ±10% 1 phase ±10% 3 phase VAC +10% 3 phase VAC +10% 3 phase VAC +10% Input frequency - 50 or 60Hz +5% Service factor Duty - continuous Humidity - 90% max RH non-condensing Altitude feet (1000m) max without derate Protective Features Adjustable current limit Isolated control circuitry Digital display for fault conditions with real time clock Fault trace function Selectable automatic restart at momentary power loss DC bus charge indicator Cause of last 10 faults or alarms retained in memory 24 VDC isolated user supply Isolated encoder power supply Overload Capacity 150% for 60 seconds, 175% for 3 seconds for constant torque 115% for 60 seconds for variable torque Frequency Hz Voltage 0-maximum input voltage (RMS) Frequency 50 or 60 Hz ±5% Voltage (VAC) Phase Single Phase Three phase (single phase with derate) Impedance 1% minimum from mains connection Control Method Microprocessor controlled PWM output, selectable closed loop vector; encoderless vector; or V/Hz inverter PWM Frequency Adjustable 1-5kHz STD, 5-16 khz quiet Speed Setting ±5 VDC, 0-5 VDC ±10 VDC, 0-10 VDC, 4-20 ma, 0-20 ma; digital via keypad, Serial Comms/USB 2.0, and ModBus RTU standard Accel/Decel Separate accel/decel rates, sec. linear, s-curve, c-curve Matching Automatic tuning to motor with manual override PC Setup Software Workbench Software available via connection to USB2.0 port for commissioning wizard, firmware download, parameter viewer, scope capture and cloning Feedback Type Incremental encoder coupled to motor shaft; optional resolver feedback Feedback Pulses/Rev 60-20,000 selectable, 1024 standard Voltage Output 2 channel in quadrature, 5 VDC, differential Marker Pulse Required for position orientation Power Input 5 VDC, 12 VDC, 300 ma maximum Max. Frequency 4 MHz Positioning Buffered encoder pulse train output for position loop controller Protective Vector Trip Missing control power, over current, over voltage, under voltage, motor over speed, encoder loss Functions Over temperature (motor or control), output shorted or grounded, motor overload External Output LED indicator for trip conditions, 4 assignable logic outputs, 2 assignable analog outputs 0-10 VDC, ±10 VDC Short Circuit Phase to phase, phase to ground Keypad Running Output frequency, motor ; output current, voltage (selectable), power, energy consumed Display Setting Parameter values for setup and review Trip Separate message for each trip, last 10 trips retained in memory Ambient Temperature -10 to 45 C for UL listing Conditions Cooling Forced air OPTIONS: See page 193 for optional Expansion Boards including Eternet, Isolated Input, etc. See pages 192 for optional Dynamic Braking Assemblies. Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz Inverter/Vector & Controls Servo DC 185

186 HVAC Farm Duty Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz Inverter/Vector & Controls Inverter Drive /Vector Drive & Controls H2 Vector Drive - 115/230 and 230 Volts - Constant Torque Volt Output Current Cont. Peak Output Ratings with 2.5 khz PWM Frequency - Single Phase Input 1 115/ ZHH601-E * 1445 E1 AA 2 115/ ZHH602-E * 1619 E1 AA 3 115/ ZHH603-E * 1867 E1 AA Output Ratings with 2.5 khz PWM Frequency - Three Phase Input ZHH201-E 1445 E1 AA ZHH202-E 1619 E1 AA ZHH203-E 1867 E1 AA ZHH205-E 2085 E1 AA 7 1/ ZHH207-E 2461 E1 AA ZHH210-E 3456 E1 B ZHH215-E 4396 E1 B ZHH220-E 5007 E1 B ZHH225-E 7164 E1 C ZHH230-E 7829 E1 C ZHH240-E E1 C ZHH250-E ** E1 D ZHH260-E ** E1 D Output Ratings with 8.0 khz PWM Frequency - "Quiet Drive " - Single Phase Input 3/4 115/ ZHH601-E * 1445 E1 AA 1 115/ ZHH602-E * 1619 E1 AA 2 115/ ZHH603-E * 1867 E1 AA Output Ratings with 8.0 khz PWM Frequency - "Quiet Drive " - Three Phase Input ZHH201-E 1445 E1 AA ZHH203-E 1867 E1 AA ZHH205-E 2085 E1 AA ZHH207-E 2461 E1 AA 7 1/ ZHH210-E 3456 E1 B ZHH215-E 4396 E1 B ZHH220-E 5007 E1 B ZHH225-E 7164 E1 C ZHH230-E 7829 E1 C ZHH240-E E1 C ZHH250-E ** E1 D ZHH260-E ** E1 D OPTIONS: Dimensions are listed on page 191. See pages 193 for optional Expansion Boards. See pages 192 for optional Dynamic Braking Assemblies. See notes on pages 8 and 9, and inside back flap. * Single phase input voltage to control, three phase output voltage from control to motor. ** Available Q Red catalog number = New item Size Servo DC 186

187 Inverter Drive /Vector Drive & Controls H2 Vector Drive - 115/230 and 230 Volts - Variable Torque Volt Output Current Cont. Peak Output Ratings with 2.5 khz PWM Frequency - Single Phase Input 2 115/ ZHH601-E * 1445 E1 AA 3 115/ ZHH602-E * 1619 E1 AA Output Ratings with 2.5 khz PWM Frequency - Three Phase Input ZHH201-E 1445 E1 AA ZHH202-E 1619 E1 AA ZHH203-E 1867 E1 AA 7 1/ ZHH205-E 2085 E1 AA ZHH207-E 2461 E1 AA ZHH210-E 3456 E1 B ZHH215-E 4396 E1 B ZHH225-E 7164 E1 C ZHH230-E 7829 E1 C ZHH240-E E1 C ZHH250-E ** E1 D ZHH260-E ** E1 D Output Ratings with 8.0 khz PWM Frequency - "Quiet Drive " - Single Phase Input 1 115/ ZHH601-E * 1445 E1 AA 2 115/ ZHH602-E * 1619 E1 AA 3 115/ ZHH603-E * 1867 E1 AA Output Ratings with 8.0 khz PWM Frequency - "Quiet Drive " - Three Phase Input ZHH201-E 1445 E1 AA ZHH202-E 1619 E1 AA ZHH203-E 1867 E1 AA ZHH205-E 2085 E1 AA 7 1/ ZHH207-E 2461 E1 AA ZHH210-E 3456 E1 B ZHH215-E 4396 E1 B ZHH220-E 5007 E1 B ZHH225-E 7164 E1 C ZHH230-E 7829 E1 C ZHH240-E E1 C ZHH250-E ** E1 D ZHH260-E ** E1 D OPTIONS: Dimensions are listed on page 191. See pages 193 for optional Expansion Boards. See pages 192 for optional Dynamic Braking Assemblies. See notes on pages 8 and 9, and inside back flap. * Single phase input voltage to control, three phase output voltage from control to motor. ** Available Q Red catalog number = New item Size HVAC Farm Duty Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz Inverter/Vector & Controls DC Servo 187

188 HVAC Farm Duty Definite Purpose Brake 200 & 575 Volt IEC H2 Vector Drive Volts - Constant Torque Volt Inverter Drive /Vector Drive & Controls Output Current Cont. Peak Output Ratings with 2.5 khz PWM Frequency ZHH401-E 1918 E1 AA ZHH402-E 2201 E1 AA ZHH403-E 2522 E1 AA ZHH405-E 2787 E1 AA 7 1/ ZHH407-E 3983 E1 AA ZHH410-E 4146 E1 AA ZHH415-E 4478 E1 B ZHH420-E 5086 E1 B ZHH425-E 6512 E1 B ZHH430-E 7953 E1 C ZHH440-E 9578 E1 C ZHH450-E E1 C ZHH460-E ** E1 D ZHH475-E ** E1 D Output Ratings with 8.0 khz PWM Frequency - "Quiet Drive " ZHH401-E 1918 E1 AA ZHH403-E 2522 E1 AA ZHH405-E 2787 E1 AA ZHH407-E 3983 E1 AA 7 1/ ZHH410-E 4146 E1 AA ZHH415-E 4478 E1 B ZHH420-E 5086 E1 B ZHH425-E 6512 E1 B ZHH430-E 7953 E1 C ZHH440-E 9578 E1 C ZHH450-E E1 C ZHH460-E ** E1 D ZHH475-E ** E1 D OPTIONS: Dimensions are listed on page 191. See pages 193 for optional Expansion Boards. See pages 192 for optional Dynamic Braking Assemblies. See notes on pages 8 and 9, and inside back flap. ** Available Q Red catalog number = New item Size 50 Hertz Inverter/Vector & Controls Servo DC 188

189 H2 Vector Drive Volts - Variable Torque Volt Inverter Drive /Vector Drive & Controls Output Current Cont. Peak Output Ratings with 2.5 khz PWM Frequency ZHH401-E 1918 E1 AA ZHH402-E 2201 E1 AA ZHH403-E 2522 E1 AA 7 1/ ZHH405-E 2787 E1 AA ZHH407-E 3983 E1 AA ZHH410-E 4146 E1 AA ZHH415-E 4478 E1 B ZHH420-E 5086 E1 B ZHH425-E 6512 E1 B ZHH430-E 7953 E1 C ZHH440-E 9578 E1 C ZHH450-E E1 C ZHH460-E ** E1 D ZHH475-E ** E1 D Output Ratings with 8.0 khz PWM Frequency - "Quiet Drive " ZHH401-E 1918 E1 AA ZHH402-E 2201 E1 AA ZHH403-E 2522 E1 AA ZHH405-E 2787 E1 AA 7 1/ ZHH407-E 3983 E1 AA ZHH410-E 4146 E1 AA ZHH415-E 4478 E1 B ZHH420-E 5086 E1 B ZHH425-E 6512 E1 B ZHH430-E 7953 E1 C ZHH440-E 9578 E1 C ZHH450-E E1 C ZHH460-E ** E1 D ZHH475-E ** E1 D OPTIONS: Dimensions are listed on page 191. See pages 193 for optional Expansion Boards. See pages 192 for optional Dynamic Braking Assemblies. See notes on pages 8 and 9, and inside back flap. ** Available Q Red catalog number = New item Size HVAC Farm Duty Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz DC Servo Inverter/Vector & Controls 189

190 HVAC Farm Duty Definite Purpose Brake 200 & 575 Volt IEC H2 Vector Drive Volts - Constant Torque Volt Inverter Drive /Vector Drive & Controls Output Current Cont. Peak Output Ratings with 2.5 khz PWM Frequency ZHH501-E 2207 E1 AA ZHH502-E 2531 E1 AA ZHH503-E 2900 E1 AA ZHH505-E 3204 E1 AA 7 1/ ZHH507-E 4042 E1 AA ZHH510-E 4506 E1 AA ZHH515-E 5374 E1 B ZHH520-E 6258 E1 B ZHH525-E 7882 E1 B ZHH530-E 8900 E1 C ZHH540-E E1 C ZHH550-E E1 C ZHH560-E ** E1 D ZHH575-E ** E1 D Output Ratings with 8.0 khz PWM Frequency - "Quiet Drive " ZHH501-E 2207 E1 AA ZHH503-E 2900 E1 AA ZHH505-E 3204 E1 AA ZHH507-E 4042 E1 AA 7 1/ ZHH510-E 4506 E1 AA ZHH515-E 5374 E1 B ZHH520-E 6258 E1 B ZHH525-E 7882 E1 B ZHH530-E 8900 E1 C ZHH540-E E1 C ZHH550-E E1 C ZHH560-E ** E1 D ZHH575-E ** E1 D OPTIONS: See pages 193 for optional Expansion Boards. See pages 192 for optional Dynamic Braking Assemblies. See notes on pages 8 and 9, and inside back flap. ** Available Q Red catalog number = New item Size 50 Hertz Inverter/Vector & Controls Servo DC 190

191 H2 Vector Drive Volts - Variable Torque Volt Inverter Drive /Vector Drive & Controls Output Current Cont. Peak Output Ratings with 2.5 khz PWM Frequency OPTIONS: See pages 193 for optional Expansion Boards. See pages 192 for optional Dynamic Braking Assemblies. See notes on pages 8 and 9, and inside back flap. ** Available Q Red catalog number = New item ZHH501-E 2207 E1 AA ZHH502-E 2531 E1 AA ZHH503-E 2900 E1 AA 7 1/ ZHH505-E 3204 E1 AA ZHH507-E 4042 E1 AA ZHH510-E 4506 E1 AA ZHH515-E 5374 E1 B ZHH520-E 6258 E1 B ZHH525-E 7882 E1 B ZHH530-E 8900 E1 C ZHH540-E E1 C ZHH550-E E1 C ZHH560-E ** E1 D ZHH575-E ** E1 D Output Ratings with 8.0 khz PWM Frequency - "Quiet Drive " ZHH501-E 2207 E1 AA ZHH502-E 2531 E1 AA ZHH503-E 2900 E1 AA ZHH505-E 3204 E1 AA 7 1/ ZHH507-E 4042 E1 AA ZHH510-E 4506 E1 AA ZHH515-E 5374 E1 B ZHH520-E 6258 E1 B ZHH525-E 7882 E1 B ZHH530-E 8900 E1 C ZHH540-E E1 C ZHH550-E E1 C ZHH560-E ** E1 D ZHH575-E ** E1 D Size HVAC Farm Duty Definite Purpose Brake 200 & 575 Volt IEC Dimensions in/(mm) Size Outside Mounting Ap x Height Width Depth Height Width AA /(312) 7.974/(203) 8.21/(208) 11.75/(298) 7.38/(187) 20 B /(457) 9.100/(231) 9.75/(248) 17.25/(438) 7.00/(178) 30 C /(559) 9.100/(231) 9.75/(248) 21.25/(540) 7.00/(178) 60 D Available Q Hertz Inverter/Vector & Controls DC Servo 191

192 HVAC Farm Duty Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz Inverter/Vector & Controls Servo H2 Drive Keypad Extension Cable Inverter Drive /Vector Drive & Controls For the convenience of our customers, we offer a connector plug/cable assembly. This assembly provides the connectors from the keypad to the control for remote keypad operation. Cable Extension Length CBLHH015KP 5 feet (1.5 meter) 41 E8 1 CBLHH030KP 10 feet (3.0 meter) 59 E8 1 CBLHH046KP 15 feet (4.6 meter) 77 E8 1 CBLHH061KP 20 feet (6.1 meter) 95 E8 2 CBLHH091KP 30 feet (9.1 meter) 112 E8 3 CBLHH152KP 50 feet (15.2 meter) 159 E8 3 CBLHH229KP 75 feet (22.9 meter) 230 E8 4 CBLHH305KP 100 feet (30.5 meter) 301 E8 5 CBLHH457KP 150 feet (45.7 meter) 422 E8 7 CBLHH610KP 200 feet (61.0 meter) 540 E8 9 NOTE: Custom lengths available. Red catalog number = New item H2 Drive Dynamic Braking Resistor Assemblies Dynamic Braking Resistor Assemblies include braking resistors completely assembled and mounted into a 1 enclosure. Select the braking resistor that has correct ohm value for the control and adequate continuous watts capacity to meet load requirements. Input Volts Total Continuous Rated Watts Ohms RGA630 RGA1230 RGA RGA620 RGA1220 RGA2420 RGA RGA1210 RGA2410 RGA RGA1206 RGA2406 RGA RGA1204 RGA2404 RGA RGA RGA6120 RGA12120 RGA RGA660 RGA1260 RGA2460 RGA RGA620 RGA1220 RGA2420 RGA RGA1210 RGA2410 RGA RGA6200 RGA12200 RGA RGA6120 RGA12120 RGA RGA660 RGA1260 RGA2460 RGA RGA630 RGA1230 RGA2430 RGA RGA1224 RGA2424 RGA RGA E8 E8 E8 E8 DC 192

193 Inverter Drive /Vector Drive & Controls H2 Drive Expansion Boards Baldor offers a wide variety of plug-in expansion boards for the Series H2 Inverter, H2 Vector, and H2 Servo Drives. Expansion boards allow the drive to be interfaced with various inputs and outputs. Each control has the capability to utilize up to two expansion boards. Board Description EXBHH001A01 EXBHH002A01 EXBHH003A01 EXBHH005A01 EXBHH007A01 EXBHH012A01 EXBHH013A01 EXBHH014A01 EXBHH016A01 Ethernet Server Expansion Board Provides easy connection to all drive parameters for setup and review using any PC based Web Browser via an Ethernet connection. Download parameter values, operating conditions, and fault log data for review and archive. Uses standard RJ-45 female terminal for ethernet connection. Mint Expansion Board Provides standalone Position Controller capability for a single axis and is programmable in MINT. Position capabilities include Master Axis Follower, Electronic Gearbox, Flying Shears, Registration, Virtual Master, and CAM functions. uses MINT Workbench V5 for setup and diagnostics. Master encoder input supports differential inputs for A, B and Z (Index pulse) and uses DB9 for connection. One CAN open channel is available for connection to additional I/O breakout box or CAN HMI terminal. Connection to PC is via USB1.1 connector. Includes CD Rom, and 2m USB cable. Isolated Input Expansion Board Contains 9 isolated inputs jumper configurable for VAC. All inputs must be the same voltage one side of all inputs is common. This board replaces all the opto inputs on the main control board. Uses screw terminals for connection. High Resolution Analog Input/Output Board Provides 2 additional analog inputs and 2 additional analog outputs with up to 16 bits resolution. Acceptable DC inputs: ±10V, 0-10V, ±5V, with 300 microvolt resolution. Current inputs: 0-20mA, 4-20mA, with 0.6 microamp resolution. Input ± 10 V 0-10 V ± 5 V 0-5 V 0-20 ma 4-20 ma Resolution 16 bit 15 bit 15 bit 14 bit 15 bit 15 bit All inputs can be inverted through software. Analog Outputs can be ±10V, 0-10V, ±5V, 0-20mA or 4-20mA Master Pulse Reference / Isolated Pulse Follower Bi-directional jumper selectable for: 1. Accepts a 5V or 12V quadrature pulse train input or pulse and direction input to use as a master reference. 2. Re-transmits the input pulse train at 5 V dc for different ratios from 1:20 up to 65535:1. (Scaled output) 3. Can be used as a auxillary encoder input to the control. 4. A CANOpen port utilizing a RJ-45 female connector for adding an additional I/O breakout box or CAN HMI terminal. Ethernet IP Communications Expansion Board Allows H2 Drives to be connected to Ethernet IP Communications Bus. Uses plug-in terminals for connection. DeviceNet Expansion Board Allows H2 Drives to be connected to DeviceNet Communications Bus. Uses plug-in terminals for connection. Profibus DP Expansion Board Allows H2 Drives to be connected to Profibus Communications Bus. Uses DB - 9 female tyoe connector LonWorks Communications Expansion Board Allows H2 Drives to be connected to LonWorks Communications Bus. Uses RJ-45 female type connector. 152 E8 696 E8 197 E8 308 E8 503 E8 512 E8 521 E8 626 E8 512 E8 HVAC Farm Duty Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz Inverter/Vector & Controls Servo DC 193

194 HVAC Farm Duty Series 15H Inverter Inverter Drive /Vector Drive & Controls 3/4 thru VAC 3 Phase - 50/60 Hz 3/4 thru VAC 3 Phase - 50/60 Hz 3/4 thru VAC 3 Phase - 60 Hz Applications: Constant torque, variable torque or constant horsepower applications. New installations, replacements and original equipment manufacturers (OEM). Definite Purpose Brake 200 & 575 Volt Design Specifications Process follower 0-5 VDC, 0-10 VDC, 4-20 ma Free run or ramp stop Selectable preset speeds Jog speed Dynamic braking (optional size C2 and larger) DC injection braking 2 analog meter outputs 2 opto isolated outputs 2 relay outputs Through wall & panel mount size C2, E and F. Features: 1 enclosure as standard. Output frequency 0.25 to 400 Hz with peak overload capacity of %. Separate accel/decel rates and controlled reversing. Built in two and three input PID process control loop. Operator Keypad Forward/Reverse command RUN and JOG Local/Remote key Stop command Parameter setting and display 32 character display Remote mount to 100 feet (60m) from control 4X enclosure when mounted on panel Environmental and Operating Conditions Input voltage 3 phase VAC ±10% 3 phase VAC ±10% 3 phase VAC ±10% Input frequency - 50 or 60Hz ±5% Service factor Duty - continuous Humidity - 90% max RH non-condensing Altitude feet (1000m) max without derate Protective Features Selectable automatic restart at momentary power loss DC bus charge indicator Fault indicator Adjustable time based overload Cause of last 31 trips retained in memory Digital display for fault conditions Linear heat sink thermal sensor Isolated control circuitry IEC 50 Hertz Inverter/Vector & Controls Servo DC 194 Output Ratings Input Ratings Control Spec Protective Functions LCD Display Ambient Conditions Overload Capacity 150% for 60 seconds; % for 3 seconds for constant torque 115% for 60 seconds for variable torque Frequency Hz Voltage 0-Maximum input voltage (RMS) Frequency 50 or 60 Hz ± 5% Voltage VAC; VAC, VAC Phase Three phase (or single phase with derate) Impedance 1% minimum for size C2, F, G and G2 (3% minimum required for size A, B, D and E) Control Method Sinewave carrier input, PWM output PWM Frequency Adjustable 1-5 khz standard, 1-15 khz quiet V/Hz Ratio Linear to squared reduced, base frequency, output voltage, minimum frequency limit, maximum frequency limit Torque Boost 0-15% of input voltage; automatic with manual override Brake Torque 20% standard on -E and -W; and -EO requires external assembly Skip Frequency Three zones 0-Max frequency Frequency Setting 0-5 VDC, 0-10 VDC, 4-20mA, digital via optional RS232/485 Accel/Decel Separate accel/decel rates, sec to maximum frequency Inverter Trip Over voltage, over current, under voltage, external trip, heatsink thermal, motor overload Stall Prevention Over voltage suppression, overcurrent suppression External Output OPTO isolated outputs, relay outputs, and LED indicator for trip Short Circuit Phase to phase, phase to ground Running Output frequency, set frequency, output current(%), voltage,, custom units Setting Parameter values for setup and review Trip Separate message for each trip, cause of last 31 trips retained in memory Temperature -10 to + 40 C For UL ing Cooling Forced air included when required OPTIONS: See page for optional Expansion Boards including RS-232, RS-485 isolated input etc. See page for optional Dynamic Braking Assemblies.

195 Series 15H Inverter Volts - Constant Torque Standard Mode 2.5 khz Output Current Inverter Drive /Vector Drive & Controls Quiet Drive 8.0 khz Output Current Cont. Peak Cont. Peak ID15H201-E / E1 A ID15H202-E E1 A ID15H203-E E1 A ID15H205-E E1 A ID15H207-E 7 1/ E1 B ID15H210-E / E1 B ID15H215-E E1 B ID15H220-EO E1 C2 ID15H225-EO E1 C2 ID15H230-EO E1 C2 ID15H240-MO E1 D ID15H250-MO E1 D Series 15H Inverter Volts - Variable Torque Size HVAC Farm Duty Definite Purpose Brake Standard Mode 2.5 khz Output Current Quiet Drive 8.0 khz Output Current Cont. Peak Cont. Peak ID15H201-E E1 A ID15H202-E E1 A ID15H203-E E1 A ID15H205-E 7 1/ E1 A ID15H207-E / E1 B ID15H210-E E1 B ID15H215-E E1 B ID15H220-EO E1 C2 ID15H225-EO E1 C2 ID15H230-EO E1 C2 ID15H240-MO E1 D ID15H250-MO E1 D OPTIONS: Dimensions are listed on page 197. See pages for optional Expansion Boards. See pages for optional Dynamic Braking Assemblies. See notes on pages 8 and 9, and inside back flap. Size 200 & 575 Volt IEC 50 Hertz DC Servo Inverter/Vector & Controls 195

196 HVAC Farm Duty Definite Purpose Brake 200 & 575 Volt Series 15H Inverter Volts - Constant Torque Standard Mode 2.5 khz Output Current Inverter Drive /Vector Drive & Controls Quiet Drive 8.0 khz Output Current Cont. Peak Cont. Peak ID15H401-E / E1 A ID15H402-E E1 A ID15H403-E E1 A ID15H405-E E1 A ID15H407-E 7 1/ E1 A ID15H410-E / E1 B ID15H415-E E1 B ID15H420-EO E1 C2 ID15H425-EO E1 C2 ID15H430-EO E1 C2 ID15H440-EO E1 C2 ID15H450-EO E1 D ID15H460-EO E1 D ID15H475-EO E1 E ID15H4100-EO E1 E ID15H4150V-EO E1 E ID15H4150-EO E1 F ID15H4200-EO E1 F ID15H4250-EO E1 F ID15H4300-EO E1 G2 ID15H4350-EO E1 G2 ID15H4400-EO E1 G2 ID15H4450-EO E1 G Size IEC 50 Hertz Inverter/Vector & Controls Servo DC 196 Series 15H Inverter Volts - Variable Torque Standard Mode 2.5 khz Output Current Quiet Drive 8.0 khz Output Current Cont. Peak Cont. Peak ID15H401-E E1 A ID15H402-E E1 A ID15H403-E E1 A ID15H405-E 7 1/ E1 A ID15H407-E / E1 A ID15H410-E E1 B ID15H415-E E1 B ID15H420-EO E1 C2 ID15H425-EO E1 C2 ID15H430-EO E1 C2 ID15H440-EO E1 C2 ID15H450-EO E1 D ID15H460-EO E1 D ID15H475-EO E1 E ID15H4100-EO E1 E ID15H4150V-EO E1 E ID15H4150-EO E1 F ID15H4200-EO E1 F ID15H4250-EO E1 F ID15H4300-EO E1 G2 ID15H4350-EO E1 G2 ID15H4400-EO E1 G2 ID15H4450-EO E1 G OPTIONS: Dimensions are listed on page 197. See pages for optional Expansion Boards. See pages for optional Dynamic Braking Assemblies. See notes on pages 8 and 9, and inside back flap. Size

197 Series 15H Inverter Volts - Constant Torque Standard Mode 2.5 khz Output Current Inverter Drive /Vector Drive & Controls Quiet Drive 8.0 khz Output Current Cont. Peak Cont. Peak ID15H501-E / E1 A ID15H502-E E1 A ID15H503-E E1 A ID15H505-E E1 A ID15H507-E 7 1/ E1 A ID15H510-E / E1 B ID15H515-E E1 B ID15H520-EO E1 C2 ID15H525-EO E1 C2 ID15H530-EO E1 C2 ID15H540-EO E1 C2 ID15H550-EO E1 D ID15H560-EO E1 D ID15H575-EO E1 E ID15H5100-EO E1 E ID15H5150V-EO E1 E Size HVAC Farm Duty Definite Purpose Brake Series 15H Inverter Volts - Variable Torque Dimensions in/(mm) Standard Mode 2.5 khz Output Current Quiet Drive 8.0 khz Output Current Cont. Peak Cont. Peak OPTIONS: See pages for optional Expansion Boards. See pages for optional Dynamic Braking Assemblies. See notes on pages 8 and 9, and inside back flap. ID15H501-E E1 A ID15H502-E E1 A ID15H503-E E1 A ID15H505-E 7 1/ E1 A ID15H507-E / E1 A ID15H510-E E1 B ID15H515-E E1 B ID15H520-EO E1 C2 ID15H525-EO E1 C2 ID15H530-EO E1 C2 ID15H540-EO E1 C2 ID15H550-EO E1 D ID15H560-EO E1 D ID15H575-EO E1 E ID15H5100-EO E1 E ID15H5150V-EO E1 E Size 200 & 575 Volt IEC 50 Hertz Inverter/Vector & Controls Size Outside Mounting Ap x Height Width Depth Height Width A /(312) 7.974/(203) 7.120/(181) 11.5/(292) 7.2/(183) 20 B 15.4/(391) 10/(254) 7.1/(180) 14.6/(371) 9.2/(234) 30 C /(431) 10.50/(267) 9.66/(245) 15.58/(396) 7.76/(197) 60 D 25/(635) 14.5/(368) 10/(250) 24.25/(616) 13.5/(343) 90 E 30/(762) 17.7/(450) 12/(305) 29/(737) 14.25/(362) 200 F 45/(1143) 27/(686) 13/(330) 44/(1118) 22.75/(578) 370 G 93/(2362) 31.5/(800) 23.6/(600) Floor Mount 700 G /(1676) 31.6/(803) 23.49/(597) Floor Mount 600 Servo DC 197

198 HVAC Farm Duty Series 15H Washdown Inverter Inverter Drive /Vector Drive & Controls 3/4 thru VAC 3 Phase - 50/60 Hz 3/4 thru VAC 3 Phase - 50/60 Hz Applications: Constant torque, variable torque or constant horsepower applications. New installations, replacements and original equipment manufacturers. (OEM). Suitable for frequent washdowns. Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz Inverter/Vector & Controls Servo DC Design Specifications Process follower 0-5VDC, 0-10VDC,4-20mA Free run or ramp stop Selectable preset speeds Jog speed Dynamic braking DC injection braking 2 analog meter outputs 2 opto isolated output 2 relay outputs Output Ratings Input Ratings Control Spec Protective Functions LCD Display Ambient Conditions Features: 4X enclosure as standard. Output frequency 0.25 to 400 Hz with peak overload capacity of 200%. Separate accel/decel rates and controlled reversing. Built in two and three input PID process control loop. Operator Keypad Forward/Reverse command RUN and JOG Local/Remote key Stop command Parameter setting and display 32 character display Remote mount to 100 feet (60M) from control 4X enclosure when mounted on panel OPTIONS: See pages for optional Expansion Boards including RS-232, RS-485 etc. Environmental and Operating Conditions Input voltage 3 phase VAC+10% 3 phase VAC +10% Input frequency 50 or 60Hz +5% Service factor Duty - continuous Humidity - 100% max RH Altitude feet (1000m) max without derate Protective Features Selectable automatic restart at momentary power loss DC bus charge indicator Fault indicator Adjustable time based overload Cause of last 31 trips retained in memory Digital display for fault conditions Isolated control circuitry Overload Capacity 150% for 60 seconds; % for 3 seconds for constant torque 115% for 60 seconds for variable torque Frequency Hz optional Hz Voltage 0-Maximum input voltage (RMS) Frequency 50 or 60 Hz ± 5% Voltage VAC; VAC Phase Three phase (or single phase with derate) Impedance 3% minimum required for size A, B Control Method Sinewave carrier input, PWM output PWM Frequency Adjustable 1-5 khz standard, 1-15 khz quiet V/Hz Ratio Linear to squared reduced, base frequency, output voltage, minimum frequency limit, maximum frequency limit Torque Boost 0-15% of input voltage; automatic with manual override Brake Torque 20% standard on -E and -W Skip Frequency Three zones 0-Max frequency Frequency Setting 0-5 VDC, 0-10 VDC, 4-20mA, digital via optional RS232/485 Accel/Decel Separate accel/decel rates, sec to maximum frequency Inverter Trip Over voltage, over current, under voltage, external trip, heatsink thermal, motor overload Stall Prevention Over voltage suppression, overcurrent suppression External Output OPTO isolated outputs, relay outputs and LED indicator for trip Short Circuit Phase to phase, phase to ground Running Output frequency, set frequency, output current(%), voltage,, custom units Setting Parameter values for setup and review Trip Separate message for each trip, cause of last 31 trips retained in memory Temperature 0 to 40 C for UL listing Cooling Forced air included when required 198

199 Inverter Drive /Vector Drive & Controls Series 15H Washdown Inverter Volts - Constant Torque Dimensions in/(mm) Size Height Standard Mode 2.5 khz Output Current Series 15H Washdown Inverter Volts - Constant Torque NOTE: See notes on pages 8 and 9, and inside back flap. Outside Width Depth Quiet Drive 8.0 khz Output Current Cont. Peak Cont. Peak Height Mounting ID15H201-W / E1 A ID15H202-W E1 A ID15H203-W E1 A ID15H205-W E1 A ID15H207-W 7 1/ E1 B ID15H210-W / E1 B ID15H215-W E1 B Series 15H Washdown Inverter Volts - Variable Torque Standard Mode 2.5 khz Output Current Quiet Drive 8.0 khz Output Current Cont. Peak Cont. Peak ID15H201-W E1 A ID15H202-W E1 A ID15H203-W E1 A ID15H205-W 7 1/ E1 A ID15H207-W / E1 B ID15H210-W E1 B ID15H215-W E1 B Standard Mode 2.5 khz Output Current Quiet Drive 8.0 khz Output Current Cont. Peak Cont. Peak ID15H401-W / E1 A ID15H402-W E1 A ID15H403-W E1 A ID15H405-W E1 A ID15H407-W 7 1/ E1 A ID15H410-W / E1 B ID15H415-W E1 B Series 15H Washdown Inverter Volts - Variable Torque Standard Mode 2.5 khz Output Current Quiet Drive 8.0 khz Output Current Cont. Peak Cont. Peak ID15H401-W E1 A ID15H402-W E1 A ID15H403-W E1 A ID15H405-W 7 1/ E1 A ID15H407-W / E1 A ID15H410-W E1 B ID15H415-W E1 B Width Ap x A /(312) 7.974/(203) 7.120/(181) 11.5/(292) 7.2/(183) 20 B 15.4/(391) 10/(254) 7.1/(180) 14.6/(371) 9.2/(234) 30 Size Size Size Size HVAC Farm Duty Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz Inverter/Vector & Controls Servo DC 199

200 HVAC Farm Duty Series 18H Vector Drive Inverter Drive /Vector Drive & Controls 3/4 thru VAC 3 Phase - 50/60 Hz 3/4 thru VAC 3 Phase - 50/60 Hz 3/4 thru VAC 3 Phase - 60 Hz Applications: Constant torque or constant horsepower applications. New installations, replacements and original equipment manufacturers. (OEM). Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz Inverter/Vector & Controls Servo DC 200 Design Specifications shaft orient to marker Process follow +5VDC 0-5 VDC, +10VDC 0-10 VDC,4-20mA, digital via keypad or optional RS232/485 Linear or S-curve deceleration 15 preset speeds 2 assignable analog outputs 2 assignable opto outputs 2 assignable relay outputs 2 assignable analog inputs Through wall and panel mount size C2, E and F Output Ratings Input Ratings Control Spec Feedback Protective Functions LCD Display Ambient Conditions Features: 1 enclosure as standard. Output frequency 0-500Hz with peak overload capability of %. Automatic tuning to motor and full rated torque down to zero speed. Digital speed or torque control. Built in two and three input PID process control loop. Operator Keypad Forward/Reverse command RUN and JOG Local/Remote key Stop command 32 character display Remote mount to 100 feet (60m) from control 4X enclosure when mounted on panel Environmental and Operating Conditions Input voltage 3 phase VAC +10% 3 phase VAC +10% 3 phase VAC +10% Input frequency 50 or 60Hz +5% Service factor Duty - continuous Humidity - 90% max RH non-condensing Altitude feet (1000m) max without derate OPTIONS: See pages for optional Expansion Boards including RS-232, RS-485. See page 203 for enclosure Dimensions See pages for optional Dynamic Braking Assemblies. Protective Features Adjustable current limit Isolated control circuitry Digital display for fault conditions Selectable automatic restart at momentary power loss DC bus charge indicator Cause of last 31 trips retained in memory Overload Capacity 150% for 60 seconds, % for 3 seconds for constant torque 115% for 60 seconds for variable torque Frequency Hz Voltage 0-maximum input voltage (RMS) Frequency 50 or 60 Hz ±5% Voltage VAC; VAC; VAC Phase Three phase (or single phase with derate) Impedance 1% minimum for size C2, F, G, and G2 (3% minimum required for Size A, B, D and E) Control Method Microprocessor controlled PWM output PWM Frequency Adjustable 1-5kHz STD, 1-16 khz quiet Speed Setting ±5 VDC, 0-5 VDC ±10 VDC, 0-10 VDC, 4-20 ma; digital via keypad, RS232/485 Accel/Decel sec. Matching Automatic tuning to motor with manual override Feedback Type Incremental encoder coupled to motor shaft Pulses/Rev 60-15,000 selectable, 1024 standard Voltage Output 2 channel in quadrature, 5 VDC, differential Marker Pulse Required for position orientation Power Input 5 VDC, 300 ma maximum Max. Frequency 1 MHz Positioning Buffered encoder pulse train output for position loop controller Vector Trip Missing control power, over current, over voltage, under voltage, motor over speed Over temperature (motor or control), output shorted or grounded, motor overload External Output LED indicator for trip conditions, 4 assignable logic outputs, 2 assignable analog outputs 0-5 VDC Short Circuit Phase to phase, phase to ground Running Output frequency, motor ; output current, voltage (selectable) Setting Parameter values for setup and review Trip Separate message for each trip, last 31 trips retained in memory Temperature -10 to 40 C for UL listing Cooling Forced air included when required

201 Series 18H Vector Volts continued Volt Inverter Drive /Vector Drive & Controls Output Current Cont. Peak Constant Torque - 18H Vector - Output Ratings with 2.5 khz PWM Frequency ZD18H201-E 1603 E1 A ZD18H202-E 1798 E1 A ZD18H203-E 2073 E1 A ZD18H205-E 2314 E1 A 7 1/ ZD18H207-E 2732 E1 B ZD18H210-E 3836 E1 B ZD18H215-E 4878 E1 B ZD18H220-EO 5557 E1 C ZD18H225-EO 7949 E1 C ZD18H230-EO 8687 E1 C ZD18H240-MO E1 D ZD18H250-MO E1 D 18H "Quiet Drive " Vector - Output Ratings with 8.0 khz PWM Frequency 3/ ZD18H201-E 1603 E1 A ZD18H202-E 1798 E1 A ZD18H203-E 2073 E1 A ZD18H205-E 2314 E1 A ZD18H207-E 2732 E1 B 7 1/ ZD18H210-E 3836 E1 B ZD18H215-E 4878 E1 B ZD18H220-EO 5557 E1 C ZD18H225-EO 7949 E1 C ZD18H230-EO 8687 E1 C ZD18H240-MO E1 D ZD18H250-MO E1 D NOTE: -MO suffix indicates a protected chassis enclosure (not 1). See page 203 for Dimensions. See notes on pages 8 and 9, and inside back flap. OPTIONS: See pages for optional Expansion Boards. See pages for optional Dynamic Braking Assemblies. Size HVAC Farm Duty Definite Purpose Brake 200 & 575 Volt IEC DC Servo Inverter/Vector & Controls 50 Hertz 201

202 HVAC Farm Duty Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz Inverter/Vector & Controls Servo Series 18H Vector Volts continued Volt Inverter Drive /Vector Drive & Controls Output Current Cont. Peak Constant Torque - 18H Vector - Output Ratings with 2.5 khz PWM Frequency ZD18H401-E 2129 E1 A ZD18H402-E 2441 E1 A ZD18H403-E 2799 E1 A ZD18H405-E 3094 E1 A 7 1/ ZD18H407-E 4420 E1 A ZD18H410-E 4601 E1 B ZD18H415-E 4969 E1 B ZD18H420-EO 5645 E1 C ZD18H425-EO 7226 E1 C ZD18H430-EO 8825 E1 C ZD18H440-EO E1 C ZD18H450-EO E1 D ZD18H460-EO E1 D ZD18H475-EO E1 E ZD18H4100-EO E1 E ZD18H4150V-EO E1 F ZD18H4150-EO E1 F ZD18H4200-EO E1 F ZD18H4250-EO E1 F ZD18H4300-EO E1 G ZD18H4350-EO E1 G ZD18H4400-EO E1 G ZD18H4450-EO E1 G 18H "Quiet Drive " Vector - Output Ratings with 8.0 khz PWM Frequency 3/ ZD18H401-E 2129 E1 A ZD18H402-E 2441 E1 A ZD18H403-E 2799 E1 A ZD18H405-E 3094 E1 A ZD18H407-E 4420 E1 A 7 1/ ZD18H410-E 4601 E1 B ZD18H415-E 4969 E1 B ZD18H420-EO 5645 E1 C ZD18H425-EO 7226 E1 C ZD18H430-EO 8825 E1 C ZD18H440-EO E1 C ZD18H450-EO E1 D ZD18H460-EO E1 D ZD18H475-EO E1 E ZD18H4100-EO E1 E ZD18H4150V-EO E1 F ZD18H4150-EO E1 F ZD18H4200-EO E1 F ZD18H4250-EO E1 F NOTE: See notes on pages 8 and 9, and inside back flap. OPTIONS: See pages for optional Expansion Boards. See pages for optional Dynamic Braking Assemblies. Size DC 202

203 Series 18H Vector Volts continued Volt Inverter Drive /Vector Drive & Controls Output Current Cont. Peak Constant Torque - 18H Vector - Output Ratings with 2.5 khz PWM Frequency ZD18H501-E 2449 E1 A ZD18H502-E 2809 E1 A ZD18H503-E 3218 E1 A ZD18H505-E 3556 E1 A 7 1/ ZD18H507-E 4485 E1 A ZD18H510-E 5000 E1 B ZD18H515-E 5964 E1 B ZD18H520-EO 6944 E1 C ZD18H525-EO 8747 E1 C ZD18H530-EO 9875 E1 C ZD18H540-EO E1 C ZD18H550-EO E1 D ZD18H560-EO E1 D ZD18H575-EO E1 E ZD18H5100-EO E1 E ZD18H5150V-EO E1 E 18H "Quiet Drive " Vector - Output Ratings with 8.0 khz PWM Frequency 3/ ZD18H501-E 2449 E1 A ZD18H502-E 2809 E1 A ZD18H503-E 3218 E1 A ZD18H505-E 3556 E1 A ZD18H507-E 4485 E1 A 7 1/ ZD18H510-E 5000 E1 B ZD18H515-E 5964 E1 B ZD18H520-EO 6944 E1 C ZD18H525-EO 8747 E1 C ZD18H530-EO 9875 E1 C ZD18H550-EO E1 D ZD18H560-EO E1 D Size HVAC Farm Duty Definite Purpose Brake 200 & 575 Volt IEC NOTE: See notes on pages 8 and 9, and inside back flap. OPTIONS: See pages for optional Expansion Boards. See pages for optional Dynamic Braking Assemblies. 50 Hertz Dimensions in/(mm) Size Outside Mounting Ap x Height Width Depth Height Width A /(312) 7.974/(203) 7.120/(181) 11.5/(292) 7.2/(183) 20 B 15.4/(391) 10/(254) 7.1/(180) 14.6/(371) 9.2/(234) 30 C /(431) 10.5/(267) 9.66(245) 15.58/(396) 7.76/(197) 60 D 25/(635) 14.5/(368) 10/(254) 24.25(616) 13.5/(343) 90 E 30/(762) 17.7/(450) 12/(305) 29/(737) 14.25/(362) 200 F 45/(1143) 27/(686) 13/(330) 44/(1118) 22.75/(578) 370 G 93/(2362) 31.5/(800) 23.6/(600) Floor Mount 700 G /(1676) 31.6/(803) 23.49/(597) Floor Mount 600 Inverter/Vector & Controls Servo DC 203

204 HVAC Farm Duty Series 18H Washdown Vector Inverter Drive /Vector Drive & Controls 3/4 thru VAC 3 Phase - 50/60 Hz 3/4 thru VAC 3 Phase - 50/60 Hz Applications: Constant torque or constant horsepower applications. New installations, replacements and original equipment manufacturers. (OEM). Suitable for frequent washdowns. Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz Inverter/Vector & Controls Servo DC 204 Design Specifications Process follower ±5VDC 0-5 VDC, ±10VDC 0-10 VDC, 4-20mA, digital via keypad or optional RS232/485 Linear or S-curve deceleration 15 preset speeds 2 assignable analog outputs 2 assignable opto outputs 2 assignable relay outputs Output Ratings Input Ratings Control Spec Feedback Protective Functions LCD Display Ambient Conditions Features: 4X enclosure as standard. Output frequency 0-500Hz with peak overload capability of 200%. Automatic tuning to motor and full rated torque down to zero speed. Digital speed or torque control. Built in two and three input PID process control loop. Operator Keypad Forward/Reverse command RUN and JOG Local/Remote key Stop command 32 character display Remote mount to 100 feet (60m) from control 4X enclosure when mounted on panel Environmental and Operating Conditions Input voltage Three phase VAC +10% OPTIONS: See pages for optional Expansion Boards including RS-232, RS-485. See page 205 for enclosure Dimensions See pages for optional Dynamic Braking Assemblies. Protective Features Adjustable current limit Isolated control circuitry Digital display for fault conditions Three phase VAC +10% Selectable automatic restart at Input frequency momentary power loss 50 or 60Hz +5% DC bus charge indicator Service factor Cause of last 31 trip retained Duty - continuous in memory Humidity - 100% max RH Altitude feet (1000m) max without derate Overload Capacity 150% for 60 seconds, % for 3 seconds for constant torque 115% for 60 seconds for variable torque Frequency Hz Voltage 0-maximum input voltage (RMS) Frequency 50 or 60 Hz ±5% Voltage VAC; VAC Phase Three phase (or single phase with derate) Impedance 3% minimum required for Size A, B Control Method Microprocessor controlled PWM output PWM Frequency Adjustable 1-5kHz STD, 1-16 khz quiet Speed Setting ±5 VDC, 0-5 VDC ±10 VDC, 0-10 VDC, 4-20 ma; digital via keypad, RS232/485 Accel/Decel sec. Matching Automatic tuning to motor with manual override Feedback Type Incremental encoder coupled to motor shaft Pulses/Rev 60-15,000 selectable, 1024 standard Voltage Output 2 channel in quadrature, 5 VDC, differential Marker Pulse Required for position orientation Power Input 5 VDC, 300 ma maximum Max. Frequency 1 MHz Positioning Optional buffered encoder pulse train output for position loop controller Vector Trip Missing control power, over current, over voltage, under voltage, motor over speed Over temperature (motor or control), output shorted or grounded, motor overload External Output LED indicator for trip conditions, 4 assignable logic outputs 2 assignable analog outputs 0-5 VDC Short Circuit Phase to phase, phase to ground Running Output frequency, motor ; output current, voltage (selectable) Setting Parameter values for setup and review Trip Separate message for each trip, last 31 trips retained in memory Temperature -10 to 40 C for UL listing Cooling Forced air included when required

205 Inverter Drive /Vector Drive & Controls Series 18H Washdown Vector Volt continued Volt Output Current Cont. Peak Constant Torque - 18H Washdown Vector - Output Ratings with 2.5 khz PWM Frequency ZD18H201-W 2117 E1 A ZD18H202-W 2336 E1 A ZD18H203-W 2674 E1 A ZD18H205-W 3005 E1 A 7 1/ ZD18H207-W 3511 E1 B ZD18H210-W 4944 E1 B ZD18H215-W 6294 E1 B 18H Washdown "Quiet Drive " Vector - Output Ratings with 8.0 khz PWM Frequency 3/ ZD18H201-W 2117 E1 A ZD18H202-W 2336 E1 A ZD18H203-W 2674 E1 A ZD18H205-W 3005 E1 A ZD18H207-W 3511 E1 B 7 1/ ZD18H210-W 4944 E1 B ZD18H215-W 6294 E1 B Size HVAC Farm Duty Definite Purpose Brake Series 18H Washdown Vector Volt NOTE: See notes on pages 8 and 9, and inside back flap. OPTIONS: See pages for optional Expansion Boards. Size Volt Dimensions in/(mm) Height Output Current Cont. Outside Width Peak Depth Mounting Height Constant Torque - 18H Washdown Vector - Output Ratings with 2.5 khz PWM Frequency ZD18H401-W 2768 E1 A ZD18H402-W 3130 E1 A ZD18H403-W 3669 E1 A ZD18H405-W 3981 E1 A 7 1/ ZD18H407-W 4970 E1 A ZD18H410-W 5614 E1 B ZD18H415-W 6410 E1 B 18H "Quiet Drive " Vector - Output Ratings with 8.0 khz PWM Frequency 3/ ZD18H401-W 2768 E1 A ZD18H402-W 3130 E1 A ZD18H403-W 3669 E1 A ZD18H405-W 3981 E1 A ZD18H407-W 4970 E1 A 7 1/ ZD18H410-W 5614 E1 B ZD18H415-W 6410 E1 B Width Ap x A /(312) 7.974/(203) 7.120/(181) 11.5/(292) 7.2/(183) 20 B 15.4/(391) 10/(254) 7.1/(180) 14.6/(371) 9.2/(234) 30 Size 200 & 575 Volt IEC 50 Hertz Inverter/Vector & Controls Servo DC 205

206 HVAC Farm Duty Series 22H Line Regenerative Vector Drive Inverter Drive /Vector Drive & Controls 10 thru VAC 3 Phase - 50/60 Hz 10 thru VAC 3 Phase - 50/60 Hz Applications: Variable torque, constant torque or constant horsepower applications. New installations, replacements and original equipment manufacturers. (OEM). Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz Inverter/Vector & Controls Servo DC Design Specifications Process follower ±5VDC 0-5 VDC, ±10VDC, 0-10 VDC, 4-20mA, digital via keypad or optional RS232/485 Linear or S-curve deceleration Controlled reversing 15 preset speeds 2 assignable analog outputs 2 assignable logic outputs 2 assignable relay outputs 2 assignable analog inputs shaft orient to marker Features: 1 enclosure as standard. Output frequency 0-500Hz with peak overload capability of %. Automatic tuning to motor and full rated torque down to zero speed. Digital speed or torque control. Built in two and three input PID process control loop. Operator Keypad Forward/Reverse command RUN and JOG Local/Remote key Stop command 32 character display Remote mount to 100 feet (60m) from control 4X enclosure when mounted on panel OPTIONS: See pages for optional Expansion Boards including RS-232, RS-485. Environmental and Operating Conditions Input voltage Three phase VAC +10% Protective Features Adjustable current limit Isolated control circuitry Digital display for fault conditions Three phase VAC +10% Selectable automatic restart at Input frequency momentary power loss 50 or 60Hz +5% DC bus charge indicator Service factor Cause of last 31 trips retained Duty - continuous in memory Humidity - 90% max RH non-condensing Altitude feet (1000m) max without derate Output Ratings Overload Capacity 150% for 60 seconds, % for 3 seconds for constant torque 115% for 60 seconds for variable torque Frequency Hz Voltage 0-Maximum input voltage (RMS) Input Frequency 50 or 60 Hz ±5% Ratings Voltage VAC; VAC Phase Three phase Impedance 3.0% minimum required Control Control Method Microprocessor controlled PWM output Spec PWM Frequency Adjustable 1-5kHz STD, 1-16 khz quiet Speed Setting ±5 VDC, 0-5 VDC ±10 VDC, 0-10 VDC, 4-20 ma; digital via keypad, RS232/485 Accel/Decel sec Matching Automatic tuning to motor with manual override Feedback Type Incremental encoder coupled to motor shaft Feedback Pulses/Rev 60-15,000 selectable, 1024 standard Voltage Output 2 channel in quadrature, 5 VDC, differential Marker Pulse Required for position orientation Power Input 5 VDC, 300 ma maximum Max. Frequency 1 MHz Positioning Optional buffered encoder pulse train output for position loop controller Protective Functions Vector Trip Missing control power, over current, over voltage, under voltage, motor over speed Over temperature (motor or control), output shorted or grounded, motor overload External Output LED indicator for trip conditions, 4 assignable logic outputs, 2 assignable analog outputs 0-5 VDC Short Circuit Phase to phase, phase to ground LCD Running Output frequency, motor ; output current, voltage (selectable) Display Setting Parameter values for setup and review Trip Separate message for each trip, last 31 trips retained in memory Ambient Temperature 10 to +40 C for UL listing Conditions Cooling Forced air included when required 206

207 Inverter Drive /Vector Drive & Controls Series 22H Line Regenerative Vector Volts continued Volt Output Current Cont. Peak NOTE: See page 208 for dimensions. See notes on pages 8 and 9, and inside back flap. OPTIONS: See pages for optional Expansion Boards. Constant Torque - 22H Vector Line Regenerative - Output Ratings with 2.5 khz PWM Frequency ZD22H210-EL 9451 E1 C ZD22H215-EL E1 C ZD22H220-EL E1 C ZD22H225-EL E1 C ZD22H230-EL E1 D ZD22H240-EL E1 D ZD22H250-EL E1 D+ Constant Torque - 22H "Quiet Drive " Vector Line Regenerative - Output Ratings with 8.0 khz PWM Pulse Frequency ZD22H210-EL 9451 E1 C ZD22H220-EL E1 C ZD22H225-EL E1 C ZD22H230-EL E1 D ZD22H240-EL E1 D ZD22H250-EL E1 D+ Variable Torque - 22H Vector Line Regenerative - Output Ratings with 2.5 khz PWM Frequency ZD22H210-EL 9451 E1 C ZD22H215-EL E1 C ZD22H220-EL E1 C ZD22H225-EL E1 C ZD22H230-EL E1 D ZD22H240-EL E1 D ZD22H250-EL E1 D+ Variable Torque - 22H "Quiet Drive " Vector Line Regenerative - Output Ratings with 8.0 khz PWM Pulse Frequency ZD22H210-EL 9451 E1 C ZD22H215-EL E1 C ZD22H220-EL E1 C ZD22H225-EL E1 C ZD22H230-EL E1 D ZD22H240-EL E1 D ZD22H250-EL E1 D+ Size HVAC Farm Duty Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz DC Servo Inverter/Vector & Controls 207

208 HVAC Farm Duty Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz Inverter Drive /Vector Drive & Controls Three Phase - Series 22H Line Regenerative Vector Volts continued Volt Output Current Cont. NOTE: See notes on pages 8 and 9, and inside back flap. OPTIONS: See pages for optional Expansion Boards. Peak Constant Torque - 22H Vector Line Regenerative - Output Ratings with 2.5 khz PWM Frequency ZD22H410-EL 9840 E1 C ZD22H415-EL E1 C ZD22H420-EL E1 C ZD22H425-EL E1 C ZD22H430-EL E1 D ZD22H440-EL E1 D ZD22H450-EL E1 D+ Constant Torque - 22H "Quiet Drive " Vector Line Regenerative - Output Ratings with 8.0 khz PWM Pulse Frequency ZD22H410-EL 9840 E1 C ZD22H420-EL E1 C ZD22H425-EL E1 C ZD22H430-EL E1 D ZD22H440-EL E1 D ZD22H450-EL E1 D+ Variable Torque - 22H Vector Line Regenerative - Output Ratings with 2.5 khz PWM Frequency ZD22H410-EL 9840 E1 C ZD22H415-EL E1 C ZD22H420-EL E1 C ZD22H425-EL E1 C ZD22H430-EL E1 D ZD22H440-EL E1 D ZD22H450-EL E1 D+ Variable Torque - 22H "Quiet Drive " Vector Line Regenerative - Output Ratings with 8.0 khz PWM Pulse Frequency ZD22H410-EL 9840 E1 C ZD22H415-EL E1 C ZD22H420-EL E1 C ZD22H425-EL E1 C ZD22H430-EL E1 D ZD22H440-EL E1 D ZD22H450-EL E1 D+ Size Inverter/Vector & Controls Servo DC Dimensions in/(mm) Size Outside Mounting Ap x Height Width Depth Height Width C+ 30/(762) 11.5/(292) 12.2/(310) 29.25/(743) 10.5/(267) 160 D+ 36/(914) 14.5/(368) 12.2/(310) 35.25/(895) 13.50/(343)

209 Inverter Drive /Vector Drive & Controls Series 15H, 18H, 19H, 20H, 22H and 23H Keypad Extension Cable For the convenience of our customers, we offer a connector plug/cable assembly. This assembly provides the connectors from the keypad to the control for remote keypad operation. HVAC Cable Extension Length CBLH015KP 5 feet (1.5 meter) 68 E8 1 CBLH030KP 10 feet (3.0 meter) 97 E8 1 CBLH046KP 15 feet (4.6 meter) 124 E8 1 CBLH061KP 20 feet (6.1 meter) 208 E8 2 CBLH091KP 30 feet (9.1 meter) 318 E8 3 CBLH152KP 50 feet (15.2 meter) 417 E8 3 CBLH229KP 75 feet (22.9 meter) 459 E8 4 CBLH305KP 100 feet (30.5 meter) 570 E8 5 Farm Duty Definite Purpose Brake Series 15H, 18H, and 23H Dynamic Braking Assemblies Dynamic braking assemblies include braking transistor and braking resistors completely assembled and mounted into a 1 enclosure. Select braking assembly from table with adequate maximum braking torque (%) and continuous regenerative power (Watts) capacity to meet load requirements. For use with -EO and -MO controls. 200 & 575 Volt Control input Voltage 200 To To To 600 Maximum Braking Torque In % Of Rating V % 150% 150% 150% 150% 150% 150% 150% 150% 75% 125% 150% 150% 150% 150% 150% 150% 150% 60% 100% 150% 120% 120% 150% 150% 150% 150% 45% 75% 115% 90% 90% 150% 120% 120% 150% 36% 62% 92% 72% 72% 150% 90% 90% 150% % 60% 120% 72% 72% 130% % 48% 96% 60% 60% 110% % 36% 72% 48% 48% 82% % 28% 56% 36% 36% 66% % 28% 28% 54% % % % % Cont. Watts No. RBA2-610 RBA RBA RBA4-620 RBA RBA RBA5-624 RBA RBA E8 IEC 50 Hertz DC Servo Inverter/Vector & Controls E8 E8 209

210 HVAC Farm Duty Definite Purpose Brake 200 & 575 Volt Inverter Drive /Vector Drive & Controls Series 15H, 18H, and 23H Dynamic Braking Transistor Assemblies Dynamic Braking Transistor Assemblies include braking transistor completely assembled and mounted into a 1 enclosure, to be used with External Dynamic Braking Resistor Assemblies (RGA). Select RGA assembly with matching minimum OHMS and continuous regenerative power (Watts) capacity to meet load requirements. For use with -EO and -MO Controls. Maximum Braking Torque In % Of Rating Vac Vac Vac % 150% 150% 150% 150% 150% 150% 150% 150% 150% % 150% 150% 150% 150% 150% 150% 150% 150% 150% % 150% 150% 120% 150% 150% 150% 150% 150% 150% 40 75% 115% 150% 90% 150% 150% 150% 127% 150% 150% 50 62% 92% 150% 72% 150% 150% 150% 100% 150% 150% % 150% 150% 150% 85% 145% 150% % 96% 150% 150% 68% 116% 150% % 72% 150% 150% 50% 87% 150% 150V % 56% 150% 150% 40% 70% 150% % 126% 150% 34% 58% 150% % 95% 150% 25% 44% 150% % 76% 150% - 35% 122% % 125% - 29% 100% % 108% % % 94% % % 84% % Cat. No. RTA2-6 RTA2-4 RTA2-2 RTA4-20 RTA4-10 RTA4-4 RTA4-2 RTA5-24 RTA5-14 RTA E8 E8 E8 E8 E8 E8 E8 E8 E8 E8 IEC Series 15H, 18H, and 23H Dynamic Braking Resistor Assemblies Dynamic Braking Resistor Assemblies include braking resistors completely assembled and mounted into a 1 enclosure. For 20 and above (-EO, -MO Controls), select the braking resistor from the table with the matching ohms for the RTA selected and adequate continuous watts capacity to meet load requirements. For 1 to 15 (-E,-ER Controls) select the braking resistor that has correct ohm value for the control and adequate continuous watts capacity to meet load requirements. 50 Hertz Inverter/Vector & Controls Servo DC 210 Input Total Continuous Rated Watts Volts Ohms RGA630 RGA1230 RGA RGA620 RGA1220 RGA2420 RGA RGA1210 RGA2410 RGA RGA1206 RGA2406 RGA RGA1204 RGA2404 RGA RGA4802 RGA6402 RGA9602 RGA RGA6120 RGA12120 RGA RGA660 RGA1260 RGA2460 RGA RGA630 RGA1230 RGA2430 RGA RGA620 RGA1220 RGA2420 RGA RGA1210 RGA2410 RGA RGA1204 RGA2404 RGA4804 RGA6404 RGA9604 RGA RGA4802 RGA6402 RGA9602 RGA RGA6200 RGA12200 RGA RGA6120 RGA12120 RGA RGA660 RGA1260 RGA2460 RGA RGA630 RGA1230 RGA2430 RGA RGA1224 RGA2424 RGA RGA4814 RGA E8 E8 E8 E8 E8 E8 E8

211 Inverter Drive /Vector Drive & Controls Series 15H, 18H, 19H, 20H, 22H and 23H Expansion and Accessory Boards Baldor offers a wide variety of plug-in expansion boards for Series 15H Inverters, Series 18H or 22H Vector Drives, Series 19H or 20H DC Controls and Series 23H AC Servos. Expansion boards allow the drive to be interfaced with various inputs and outputs. Each control has the capability to utilize up to two expansion boards. The following list shows boards available. The matrix shows which boards may be used together in the same control. HVAC Farm Duty Board Description ACB003A01 EXB003A04 EXB003A05 EXB004A01 EXB005A01 EXB006A01 Isolated Input/2 Relay Output Accessory Board Contains 9 Isolated inputs for VAC. All inputs must be the same voltage. Also has 2 relay outputs, Form C : N.O. and N. C. Accessory Board mounts in Expansion Board slot but uses wiring harness to connect to motor control card. Requires control board with onboard 24VDC power supply. Isolated Input Board Contains 9 isolated inputs jumper configurable for VAC or VDC. All must be the same voltage - one side of all inputs is common. This board replaces the opto inputs on the main control board. Uses screw terminals for connection. (Use with Series 15H, 18H, 22H, 23H only) Isolated Input Board Contains 9 isolated inputs jumper configurable for VAC. All must be the same voltage - one side of all inputs is common. This board replaces the opto inputs on the main control board. Uses screw terminals for connection. (Use with Series 15H, 18H, 22H, 23H only). Four Output Relays / 3-15 PSI Pneumatic Interface Converts 3-15 PSI air pressure to 0-10 VDC or 10-0 VDC (inverted). Also has four relays, 2 of which are jumper selectable as N.O. or N.C., rated for 230VAC, 5 amps max and two form C. Uses screw terminals for connections. Air hose connects to 1/8 O.D. nipple on board. Master Pulse Reference / Isolated Pulse Follower Bi-directional jumper selectable for: 1. Master quadrature pulse reference. Provides 5 volt quadrature A and B channel outputs with complements at a pulse rate proportional to accel-decel limited speed commands. Phase of B channel is reversed for reverse direction. 2. Master speed step-direction pulse reference. Provides 5 volt pulse and direction outputs with complements at a pulse rate proportional to accel-decel limited speed command. 3. Quadrature pulse follower. Provides opto isolated inputs for 5-15 volt quadrature A and B channel input speed commands and retransmits this input as 5 volt channel A and B outputs with complements at a pulse rate proportional to accel-decel limited speed command. direction reverses with input channel phase reversal. 4. Speed step and direction pulse follower. Provides opto isolated inputs for 5-15 volt input pulse and direction. Commands and retransmits these inputs as 5 volt pulse and direction outputs with complements at a pulse rate proportional to accel-decel limited speed command. DC Tachometer Interface Allows for DC tach input voltage for motor or process feedback Jumper selectable for input voltage with software trim for 10% tolerance. 250 VDC total maximum input voltage or can be used for one analog input with 16 bits resolution for ±10V and 15 bits resolution for 0-10 VDC input. Uses screw terminals for connection. 281 E8 219 E8 219 E8 404 E8 343 E8 423 E8 Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz Inverter/Vector & Controls DC Servo 211

212 HVAC Farm Duty Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz Inverter/Vector & Controls Servo DC Series 15H, 18H, 19H, 20H, 22H and 23H Expansion and Accessory Boards continued Notes on Mounting Expansion Boards plug into a slot inside the control. When using one expansion board either a Group 1 or 2 board will connect by a connector on the side of the board. When two expansion boards are used one must be from Group 1 and one from Group 2. Accessory Boards can mount into either a Group 1 or Group 2 slot. When using an Accessory Board only one other Expansion Board may be used. Inverter Drive /Vector Drive & Controls Board No. Description EXB007A02 EXB008A01 EXB010A01 EXB012A01 EXB013A01 EXB014A01 EXB015A01 High Resolution Analog Board Allows one input with up to 16 bits resolution. DC inputs: ± 10V, 0-10V, ± 5V, 0-5V, with 300 microvolt resolution. Current inputs: 4-20 ma, with 0.6 microamps resolution. Input ± 10 V 0-10 V ± 5 V 0-5 V 4-20 ma Resolution 16 bit 15 bit 15 bit 14 bit 15 bit Both the 0-10 V and 4-20 ma inputs may be inverted to 10-0 V and 20-4 ma. Two outputs, each with ± 10 VDC, 0-10 VDC or 4-20 ma with inverting capability. This replaces the analog outputs on the main control board. Uses screw terminals for connection. Isolated Encoder Feedback Board This board is recommended for use with motors that do not have an electrically isolated encoder (Baldor Vector drive motors have isolated encoders). Contains a 0-15 VDC (300mA) isolated power supply to allow use with 5, 12 and 15 VDC encoders by jumper selection. Isolates A, B and index channels with complements. The retransmitted encoder signals may be configured in two ways with a board level jumper as follows: 1. For 2 channel quadrature output (A and B with complements), set jumper to disable the marker channel (index pulse) as an input. 2. To use the marker channel (index pulse) as an input, jumper must be set to disable channel B (and compliment) output. Retransmitted signals will always be 5 VDC differential. Uses screw terminals for connection. Two analog output/three relay output board. Provides two isolated analog outputs each with 0-5VDC, 0-10VDC, or 4-20mA capability. Also includes three relay outputs jumper selectable for N.O. or N.C.rated for 230VAC, 5 amps maximum. Uses screw terminals for connection. RS232 and RS485 High Speed Serial Communications Allows Series 15H, 18H & 23H controls to be connected to RS232 half and full duplex and isolated RS485 half duplex,230.4k Baud maximum. Uses DB-9 connector for RS232 and screw terminals for RS485. DeviceNet Expansion Board Allows Series 15H, 18H, and 23H controls to be connected to DeviceNet Communications Bus. Uses plug in terminals for connection Profibus DP Expansion Board Allows Series 15H, 18H, and 23H controls to be connected to Profibus Communications Bus. Uses plug in terminals for connection Modbus plus Expansion Board Allows Series 15H, 18H, and 23H controls to be connected to Modbus Communications Bus. Uses plug in terminals for connection Group 1 Boards Isolated Input Board EXB003A04 EXB003A05 Master Pulse Reference/ Isolated Pulse Follower EXB005A01 DC Tachometer Interface EXB006A01 Isolated Encoder Feedback EXB008A E8 590 E8 343 E8 219 E8 578 E8 696 E8 832 E8 Group 2 Boards Four Output Relays / 3-15 PSI Pneumatic Interface EXB004A01 High Resolution Analog Board EXB007A02 Two analog output/three relay outputs EXB010A01 RS232/RS485 High Speed Serial Communication EXB012A01 DeviceNet Communication EXB013A01 Profibus DP Communication EXB014A01 Modbus Plus Communication EXB015A01 212

213 Three Phase - Line and Reactors Inverter Drive /Vector Drive & Controls 1 thru 500 Applications: Line side power conditioning for AC motor controls to prevent unwanted harmonics and nuisance drive trips. side power conditioning to smooth power wave form to connected motor to reduce motor electrical stresses and increase motor life. HVAC Farm Duty (Rated) kw (Rated) Input Volts Cont. Amps Features: Open construction with connection terminals. 3% impedance rating at rated current. Induct. (mh) Watts Loss 208, 230 Volt input, 60 Hz, 3% Impedance / LRAC E / / LRAC E / LRAC E / LRAC E / / LRAC E / LRAC E / LRAC E / LRAC E / LRAC080BTB 644 E LRAC110BCB 836 E LRAC130BCB 1122 E LRAC160BCB 1304 E Volt input, 60 Hz, 3% Impedance 1-1 1/ LRAC E LRAC E LRAC E / LRAC E LRAC E LRAC E LRAC E LRAC E LRAC E LRAC E LRAC110ACB2 884 E LRAC130ACB E LRAC160ACB E LRAC200ACB 1612 E LRAC250ACB E LRAC360ACB E LRAC420ACB E LRAC480ACB E LRAC600ACB 4422 E Volt input, 60 Hz, 3% Impedance LRAC E LRAC E LRAC E / LRAC E LRAC E LRAC E LRAC E LRAC E LRAC E LRAC E LRAC E LRAC110ACB2 884 E LRAC130ACB E LRAC160ACB E8 54 NOTE: See page 214 for Line Reactor enclosures. See notes on pages 8 and 9, and inside back flap. (1) 2.5% impedance rating. % impedance decreases if load current is less than reactor rated current. Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz Inverter/Vector & Controls Servo DC 213

214 HVAC Farm Duty Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz Inverter Drive /Vector Drive & Controls Three Phase - Line and Reactors continued (Rated) kw (Rated) Input Volts Cont. Amps Induct. (mh) Watts Loss Volt Input, 50 Hz, 3% Impedance LRAC E LRAC E LRAC E LRAC E / LRAC E LRAC E LRAC E LRAC E LRAC080BTB 644 E LRAC110BCB 836 E LRAC130BCB 1122 E LRAC160BCB 1304 E /400/415 Volt Input, 50 Hz, 3% Impedance LRAC E / LRAC E LRAC E / LRAC E /400/ LRAC E /400/ LRAC E / /400/ LRAC E /400/ LRAC E /400/ LRAC E LRAC E /400/ LRAC E LRAC E LRAC E LRAC160ACB E / LRAC130ACB E /400/ LRAC200ACB 1612 E / LRAC250ACB E LRAC250ACB E /400/ LRAC360ACB E /400/ LRAC420ACB E / LRAC480ACB E LRAC480ACB E8 201 Inverter/Vector & Controls Servo DC Line Reactor Enclosures 1 Enclosure No. to Fit LRAC No. LRENC-8 LRAC002-4XX LRAC01801 NOTE: See notes on pages 8 and 9, and inside back flap. Mount Type Width (IN/mm) Height (IN/mm) Depth (IN/mm) Ap x (Lbs) LRAC008-12XX LRAC01802 WALL 143 E8 8 (293) 10 (254) 6 (152) 7 LRAC01803 LRAC08002 LRENC-13 LRAC025-35XX FLOOR 283 E8 13 (330) 15 (381) 13 ( LRAC045-55XX LRENC-15 LRAC080XTB LRAC XX LRAC XX FLOOR 425 E8 15 (381) 16 (406) 13 (330) 45 LRENC-20S LRAC XCB LRAC ACB FLOOR 570 E8 20 (508) 19 (483) 16 (406)

215 Digital Speed Potentiometer with Display Inverter Drive /Vector Drive & Controls Baldor s microprocessor-based digital speed potentiometer with LED display of set speed may be used to replace the conventional 3-wire analog speed pot for most AC and DC drives. Desired set speed may be entered into the large 1/2 LED display by pressing the up and down pushbuttons: one digit at a time or in a fast sweep. Display shows 0.1% increments of full motor speed (0-100%). HVAC Farm Duty Specifications Temperature -10 C to +45 C AC input voltage VAC Input frequency 50/60 Hz Supply voltage applied across output 5 VDC to 15 VDC Speed regulation Same as driven unit Input impedance to DSP4 will drive 500 ohm to 100 K ohm Output Isolated 3-wire pseudo-pot (normal or inverted output) Display settings 0-100% of set speed range in 0.1% increments (resolution of 1000) Non-volatile memory Retains last set point upon loss of AC power (user selectable via dip switch settings) Description Input Voltage DSP4-6 Digital Speed Potentiometer with Display 456 E /240 VAC 50/60 hz Definite Purpose Brake 200 & 575 Volt Field Programmable Digital Tachometer for Rate and Time with Display Baldor offers an economical micro-processor-based digital tachometer capable of measuring motor speeds as low as 1 rpm. Unit is field programmable for desired user specified units:, FPM and GPM. Process time or other engineering units requires an input signal unit with 1 to 30,000 PPR such as the HPU and RK60 devices on page 254 IEC 50 Hertz Specifications Temperature AC input voltage Input frequency Input pulse rate Resolution Accuracy Isolated high/low alarm output -10 C to +45 C VAC 50/60 Hz 1 to 30,000 input pulses per minute from 0.01 ±0.04% display update every pulse or 0.5 seconds, whichever is longer 5 amp 240 VAC max. Inverter/Vector & Controls Servo Transducer signal input Description 0-5 to 0-24 VDC square wave (hall-effect, photoelectric, magnetic or any TTL NPN open collector device.) Input Voltage DC DTM Digital Tachometer for Rate & Time with Display 499 E /240 VAC 50/60 hz 215

216 HVAC Farm Duty Brushless AC Servo - BSM C Series Standard Inertia Servo 10.6 thru 265 lb-in Torque (1.2 thru 30 Nm) Applications: A high torque to inertia ratio in a very economical package for applications including material handling, X-Y positioning, textile machines, packaging equipment, test equipment, factory automation, semiconductor testing and manufacturing and many more. Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz Inverter/Vector & Controls Cont. Stall Torque (Lb-In) Cont. Stall Amps Nominal Bus Volts Features: For applications requiring higher inertial matching. Design includes a high continuous rated operating temperature, O-rings for moisture and dust resistance, high voltage insulation, and premium 200 C moisture resistant, multi-coated copper wire for reliability. Rated Speed () Inertia (Lb-In-Sec 2 ) BSM80C-150AA 808 E BSM80C-175AA 808 E BSM80C-250AA 855 E BSM80C-275AA 855 E BSM90C-1150AA 790 E BSM80C-350AA 881 E BSM80C-375AA 881 E BSM80C-475AA 911 E BSM100C-1150AA 1153 E BSM90C-2150AA 877 E BSM90C-2250AA 877 E BSM90C-3150AA 978 E BSM90C-3250AA 978 E BSM100C-2150AA 1287 E BSM100C-2250AA 1287 E BSM100C-3150AA 1451 E BSM100C-3250AA 1451 E BSM100C-4150AA 1706 E BSM100C-4250AA 1706 E BSM100C-6150AA 2060 E4 With 24 VDC Brakes BSM80C-175BA 1118 E BSM80C-275BA 1165 E BSM80C-375BA 1191 E BSM90C-3150BA 1361 E BSM100C-3150BA 2118 E4 NOTE: Standard configuration: all motors supplied with commutation resolver, IEC square mounting flange. BSM 50/63/80 series have two (2) threaded connectors for resolver and motor terminations. BSM 90/100 series have one (1) threaded connector for resolver. Termination of motor lead wires inside terminal box. Order cable assemblies as separate items. See page 219. BA suffix indicates 24 VDC internal electrically released spring set brake. BSM motors may be used with 230/460 volt 23H Series controls. Verify that maximum speed is not exceeded. See notes on pages 8 and 9, and inside back flap. Servo DC 216

217 Brushless AC Servo - BSM N Series Cont. Stall Torque (Lb-In) Cont. Stall Amps Nominal Bus Volts Servo Low Inertia/High Torque 3.9 thru 354 lb-in Torque (.44 thru 40 Nm) Applications: Excellent performance response in material handling, X-Y positioning, textile machines, packaging equipment, machine tool equipment, factory automation, robotics, printing machinery, indexers, flying shear applications, and more. Features: Durable and dependable. Meet 155 C temperature ratings they include premium 200 C moisture resistant, multi-coated copper wire for reliability. The insulation system includes a potted stator for added high voltage insulation protection and thermal capacity. Rated Speed () Inertia (Lb-In-Sec 2 ) BSM50N-133AA 717 E BSM50N-175AA 717 E BSM63N-150AA 1153 E BSM63N-175AA 1153 E BSM50N-233AA 826 E BSM50N-275AA 826 E BSM50N-333AA 935 E BSM50N-375AA 935 E BSM63N-250AA 1269 E BSM63N-275AA 1269 E BSM80N-150AA 1208 E BSM80N-175AA 1208 E BSM63N-350AA 1407 E BSM63N-375AA 1407 E BSM80N-250AA 1329 E BSM80N-275AA 1329 E BSM80N-350AA 1505 E BSM80N-375AA 1505 E BSM90N-175AA 1566 E BSM90N-1150AA 1566 E BSM90N-275AA 1814 E BSM90N-2150AA 1814 E BSM90N-2250AA 1814 E BSM90N-375AA 2294 E BSM90N-3150AA 2294 E BSM90N-3250AA 2294 E BSM100N-1150AA 2014 E BSM100N-2150AA 2402 E BSM100N-2250AA 2402 E BSM100N-3150AA 2766 E BSM100N-3250AA 2766 E BSM100N-4150AA 3404 E BSM100N-4250AA 3404 E4 With 24 VDC Brakes BSM63N-175BA 1462 E BSM63N-275BA 1579 E BSM80N-175BA 1518 E BSM63N-375BA 1772 E BSM80N-275BA 1638 E BSM80N-375BA 1815 E BSM90N-175BA 1949 E BSM90N-375BA 2779 E BSM100N-1150BA 2682 E BSM100N-3150BA 3556 E4 NOTE: See BSM notes on page 219 See notes on pages 8 and 9, and inside back flap. HVAC Farm Duty Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz Inverter/Vector & Controls Servo DC 217

218 HVAC Farm Duty Stainless Steel Brushless AC Servo - SSBSM Series BISSC/UL/CSA/CE Servo 3.9 thru 100 lb-in Torque (.45 thru 11.3 Nm) Applications: Designed for harsh, corrosive, or food/liquid, high hygiene environments. Pharmaceutical, washdown, packaging, food handling, beverage & dairy processing applications. Durable to handle IP67 and 1500 psi washdown conditions. Definite Purpose Features: All stainless steel to provide protection in harsh environments and washdown conditions. Reliable potted stator provides environmental, current spike and high voltage protection. Grease proven to provide 4 times greater life. Insulation UL rated and potted for extra high insulation/safety. Teflon stainless steel seal with Viton O-rings. Laser etched nameplate. Brake 200 & 575 Volt Cont. Stall Torque (Lb-In) Cont. Stall Amps Nominal Bus Volts Rated Speed () Inertia (Lb-In-Sec 2 ) SSBSM50N-175CA 1860 E SSBSM63N-375CA 2592 E SSBSM80C-175CA 1902 E SSBSM80C-275CA 1949 E SSBSM80C-475CA 2005 E SSBSM90C-3150CA 2295 E SSBSM100C-3150CA 3030 E4 NOTE: Standard SSBSM series includes IEC mounting flange. Standard SSBSM50 has as standard no keyway and no tap on shaft end. Standard SSBSM50/63/80/90/100 include two threaded stainless steel connectors for feedback and motor termination. Order feedback and power cables separately. See page 219. IEC 50 Hertz Inverter/Vector & Controls Servo DC 218

219 BSM Cable Assemblies Feet / Meters Power Cable With Threaded Connector 20 Amp Rating 12 Amp Rating 20 Amp Rating Servo Power Cable Without Connector 30 Amp Rating 10 (3.0) CBL030SP CBL030SP CBL030RP CBL030RP E8 20 (6.1) CBL061SP CBL061SP CBL061RP CBL061RP E8 30 (9.1) CBL091SP CBL091SP CBL091RP CBL091RP E8 50 (15.2) CBL152SP CBL152SP CBL152RP CBL152RP E8 NOTE: Red catalog number = New item HVAC Farm Duty Feet / Meters Feedback Cable With Threaded Connector Resolver Feedback 10 (3.0) CBL030SF-R 166 E8 20 (6.1) CBL061SF-R 220 E8 30 (9.1) CBL091SF-R 273 E8 50 (15.2) CBL152SF-R 378 E8 NOTE: BSM motors require both power cable and feedback cable. Red catalog number = New item Definite Purpose Brake DC 200 & 575 Volt SSBSM Cable Assemblies Feet / Meters 12 Amp Rating Power Cable With Threaded Connector Resolver Feedback IEC 50 Hertz Inverter/Vector & Controls Servo 5 (1.5) CBL015SP-12S 320 CBL015SF-RS 329 E8 10 (3) CBL030SP-12S 368 CBL030SF-RS 347 E8 20 (6.1) CBL061SP-12S 423 CBL061SF-RS 386 E8 30 (9.1) CBL091SP-12S 475 CBL091SF-RS 424 E8 NOTE: SSBSM motors require both power cable and feedback cable. Red catalog number = New item For additional servo motors, controls and accessories, visit 219

220 HVAC Farm Duty Definite Purpose Brake 200 & 575 Volt H2 AC Servo Control Design Specifications IGBT power devices Digital speed control or torque control Auto tuning to motor with manual-override Process follower capability Programmable linear or S-curve acceleration Simulated quadrature encoder output with index pulse 9 opto-isolated inputs 2 assignable analog outputs, 10-bit 2 assignable logic outputs 2 assignable relay outputs 2 assignable analog inputs, 12-bit USB 2.0 full speed port Plug-in I/O connectors Servo 3 thru 54 Amps 230 VAC 3 Phase 50/60 Hz 3 thru 27 Amps 460 VAC 3 Phase 50/60 Hz Applications: Automated machinery, material handling, packaging, food processing, textile fabrication, factory automation, and more. Features: y protected and uses the industry standard ± 10 VDC input command. Simple English keypad provides setup and operation. Auto-tuning to configure the control and motor. Optional expansion boards extend product capability for application needs. Operator Keypad Forward/Reverse command Jog speed Local/Remote key Stop command 128 x 64 graphical display Remote mount to 200 feet from control 4 enclosure when mounted on panel Upload and download parameter sets Help text displays Environmental and Operating Conditions Input voltage Three phase VAC ± 10% Three phase VAC ± 10% Input frequency - 50 or 60Hz +5% Service factor Duty - continuous Humidity - 90% max RH non-condensing Altitude feet max without derate Protective Features overspeed Adjustable current limit Isolated control circuitry Digital display for fault/alarm conditions with real time clock Fault trace functions 24 VDC isolated user supply Manual restart Over/Under voltage Line to line and line to ground faults Over-temperature overload IEC 50 Hertz Inverter/Vector & Controls Servo DC 220 Output Ratings Input Ratings Control Spec Feedback Keypad Display Ambient Conditions 175% for 3 seconds (constant torque mode) Overload Capacity 150% for 60 seconds (constant torque mode) Output Current See ratings table Voltage 0 to maximum input VAC Frequency 50 or 60 Hz ± 5% Voltage VAC 3 phase 60 Hz / VAC 3 phase 50 Hz VAC 3 phase 60 Hz / VAC 3 phase 50 Hz Phase Three phase (or single phase with derate) Impedance 1% minimum from mains connection Control Method Microprocessor controlled PWM output; field oriented vector control PWM Frequency Standard 8 khz - Adjustable 1-16 khz with derating between 8-16 khz Speed Setting ± 5VDC, ± 10VDC, 0-20mA, 4-20 ma, digital via Keypad or Serial Comms/USB 2.0 and ModBus RTU standard Velocity Loop Bandwith Theoretical open loop 100 Hz. maximum Current Loop Bandwith Adjustable to 500 Hz Max. Output Frequency 500 Hz Matching Auto-tuning to motor with manual override PC Setup Software Workbench Software available via connection to USB2.0 port for commissioning wizard, firmware download, parameter viewer, scope capture and cloning Feedback Type Resolver coupler to motor shaft Sine & Cosine Inputs 2 Vrms ±10% (maximum coupled) Excitation (Reference Voltage) 4 10 khz Resolver Transformation Ratio 0.5 only Positioning Output for position loop controller, simulated encoder 1024 ppr quadrature with index Display Backlit LCD; 128 x 64 graphical display Keys 14 key membrane with tactile response Remote Mount 200 feet (60.6m) maximum from control Temperature -10 to +45 C Humidity 10 to 90% RH non-condensing Altitude to 3300 feet (1000 meters) Shock 1G Vibration 0.5G at 10 to 60 Hz OPTIONS: Expansion Board: Master Pulse/Isolated Follower. High Resolution Analog, Isolated Input Board, Ethernet, Mint Expansion Board. See page for expansion and accessory boards.

221 H2 AC Servo Control Servo HVAC Input 8 khz Amps 2.5 khz Amps Voltage Cont. Peak Cont. Peak Size Constant Torque 230 Volt SHH2A03-E 1397 E3 AA SHH2A04-E 1566 E3 AA SHH2A07-E 1807 E3 AA SHH2A10-E 2018 E3 AA SHH2A16-E 2428 E3 AA SHH2A22-E 3407 E3 B SHH2A28-E 4342 E3 B SHH2A42-E 5187 E3 B SHH2A54-E 6216 E3 C Constant Torque 460 Volt 400/ SHH4A04-E 2478 E3 AA 400/ SHH4A05-E 2970 E3 AA 400/ SHH4A08-E 3855 E3 AA 400/ SHH4A11-E 3871 E3 AA 400/ SHH4A15-E 4419 E3 B 400/ SHH4A21-E 4752 E3 B 400/ SHH4A27-E 6055 E3 B NOTE: See page for optional Expansion Boards. See page for Dynamic Braking Assemblies. Farm Duty Definite Purpose Brake 200 & 575 Volt Dimensions in/(mm) Size Outside Mounting Ap x Height Width Depth Height Width AA /(312) 7.974/(203) 7.930/(201) 11.82/(300) 7.38/(187) 20 B /(457) 9.100/(231) 9.480/(241) 15.95/(405) 7.00/(178) 30 C /(559) 9.100/(231) 9.480/(241) 19.95/(507) 7.00/(178) 60 IEC 50 Hertz For additional servo motors, controls and accessories, visit Inverter/Vector & Controls DC Servo 221

222 HVAC Farm Duty Definite Purpose Brake 200 & 575 Volt Series 23H AC Servo Control Design Specifications IGBT power devices Digital speed control or torque control Auto tuning to motor with manual-override Process follower capability Programmable linear or S-curve acceleration Analog meter outputs Simulated quadrature encoder output with index pulse 9 opto-isolated inputs 2 assignable analog outputs 4 assignable logic outputs 2 assignable analog inputs Servo 3 thru 54 Amps 230 VAC 3 Phase 50/60 Hz 4 thru 27 Amps 460 VAC 3 Phase 50/60 Hz Applications: Automated machinery, material handling, packaging, food processing, textile fabrication, factory automation, and more. Features: y protected and uses the industry standard ± 10 VDC input command. Simple English keypad provides setup and operation. Auto-tuning to configure the control and motor. Optional expansion boards extend product capability for application needs. Operator Keypad Forward/Reverse command Jog speed Display 32 character alpha-numeric on backlit LCD Local/Remote key Remote mount to 100 feet 4 enclosure when mounted on panel Membrane keys with tactile feel. Environmental and Operating Conditions Input voltage Three phase VAC ±10% Three phase 478/480 VAC ±10% Input frequency - 50 or 60Hz +5% Service factor Duty - continuous Humidity - 90% max RH non-condensing Altitude feet max without derate Protective Features overspeed Adjustable current limit Isolated control circuitry Digital display for fault conditions Selectable automatic restart at momentary power loss Manual restart Over/Under voltage Line to line and line to ground faults Over-temperature overload Linear heatsink thermal sensor IEC 50 Hertz Inverter/Vector & Controls Servo DC Output Ratings Input Ratings Control Spec Feedback Keypad Display Ambient Conditions 200% for 3 seconds (constant torque mode) Overload Capacity 150% for 60 seconds (constant torque mode) Output Current See ratings table Voltage 0 to maximum input VAC Frequency 50 or 60 Hz ± 5% Voltage VAC 3 phase 60 Hz / VAC 3 phase 50 Hz VAC 3 phase 60 Hz / VAC 3 phase 50 Hz Phase Three phase (or single phase with derate) Impedance 3% minimum Control Method Microprocessor controlled PWM output PWM Frequency Standard 8 khz - Adjustable 1-16 khz with derating between 8-16 khz Speed Setting ± 5VDC, ± 10VDC, 4-20 ma Velocity Loop Bandwith Theoretical open loop 100 Hz. maximum Current Loop Bandwith Adjustable to 1500 Hz Max. Output Frequency 500 Hz Matching Auto-tuning to motor with manual override Feedback Type Resolver coupler to motor shaft Sine & Cosine Inputs 2 Vrms ±10% (maximum coupled) Excitation (Reference Voltage) 4 10 khz Resolver Transformation Ratio 0.5 only Positioning Output for position loop controller, simulated encoder 1024 ppr quadrature with index Display Backlit LDC 2 lines x 16 characters Keys 12 key membrane with tactile response Remote Mount 100 feet (30.3m) maximum from control Temperature -10 to +40 C (Derate 2% per C over 40 C to 55 C maximum) Humidity 10 to 40% RH non-condensing Altitude to 3300 feet (1000 meters) Shock 1G Vibration 0.5G at 10 to 60 Hz OPTIONS: Expansion Board: Master Pulse/Isolated Follower. High Resolution Analog, Isolated Input Board, Isolated Encoder Feedback (for PID set point), 4-output relays (for Pneumatic Interface), RS-232/485 High Speed Communication. See page for expansion and accessory boards. 222

223 Series 23H AC Servo Control Servo HVAC Input 8 khz Amps 2.5 khz Amps Voltage Cont. Peak Cont. Peak Size Constant Torque 230 Volt SD23H2A03-E 1550 E3 A SD23H2A04-E 1738 E3 A SD23H2A07-E 2005 E3 A SD23H2A10-E 2239 E3 A SD23H2A16-E 2694 E3 B SD23H2A22-E 3780 E3 B SD23H2A28-E 4817 E3 B SD23H2A42-ER 5779 E3 C SD23H2A54-ER 6897 E3 C2 Constant Torque 460 Volt 400/ SD23H4A04-E 2749 E3 A 400/ SD23H4A05-E 3296 E3 A 400/ SD23H4A08-E 4277 E3 A 400/ SD23H4A11-E 4296 E3 B 400/ SD23H4A15-E 4903 E3 B 400/ SD23H4A21-ER 5272 E3 C2 400/ SD23H4A27-ER 6719 E3 C2 NOTE: See page for optional Expansion Boards. See page for Dynamic Braking Assemblies. Farm Duty Definite Purpose Brake 200 & 575 Volt Dimensions in/(mm) Size Outside Mounting Ap x Height Width Depth Height Width A /(312) 7.974/(203) 7.120/(181) 11.5/(292) 7.2/(183) 20 B 15.4/(391) 10/(254) 7.1/(180) 14.6/(371) 9.2/(234) 30 C /(431) 10.5/(267) 9.66/(245) 15.58/(396) 7.76/(197) 60 IEC 50 Hertz For additional servo motors, controls and accessories, visit Inverter/Vector & Controls DC Servo 223

224 HVAC Farm Duty Precision Gearheads Designed Specifically for BSM Servo Servo Applications: Servo applications requiring precision, durability, and long trouble-free operation. Features: High-efficiency gearheads to maximize the power transmission capability. Designed with low backlash to reduce shock loads in dynamic reversing applications. Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz Inverter/Vector & Controls Servo DC Gearhead Shown is BSM80N with 090 gearhead Gear fits these motors BSM-N BSM-C Gear Ratio Rated Input Speed Output Rated Speed Output Rated Torque (Nm/In-Lbs.) Typical - Gearhead Dimensions Accel Torque (Nm/In-Lbs.) GBSM50-MRP050-5 (1) BSM50N-1 or /53 12/ E4 2 GBSM50-MRP (1) BSM50N /44 10/ E4 2 GBSM63-MRP070-5 (1) BSM63N-all /142 32/ E4 3 GBSM63-MRP (1) BSM63N-1 or /133 29/ E4 3 GBSM63-MRP (1) BSM63N-1 or /443 80/ E4 9 GBSM63-MRP (1) BSM63N /443 80/ E4 9 GBSM80-MRP090-4 (2) BSM80N-all BSM80C-all /443 80/ E4 7 GBSM80-MRP090-5 (2) BSM80N-all BSM80C-all /443 80/ E4 7 GBSM80-MRP090-7 (2) BSM80N-all BSM80C-all /398 72/ E4 7 GBSM80-MRP (2) BSM80N-1 or -2 BSM80C-1 or /310 72/ E4 7 GBSM80-MRP (1) BSM80N-1 or -2 BSM80C-1 or /443 80/ E4 9 GBSM80-MRP (1) BSM80N-1 BSM80C /443 80/ E4 9 GBSM80-MRP (1) BSM80N-1 or -2 BSM80C-1 or / / E4 20 GBSM80-MRP (1) BSM80N-1 BSM80C / / E4 33 GBSM90-MRP120-4 (2) BSM90N-all BSM90C-all / / E4 15 GBSM90-MRP120-5 (2) BSM90N-all BSM90C-all / / E4 15 GBSM90-MRP120-7 (2) BSM90N-all BSM90C-all / / E4 15 GBSM90-MRP (2) BSM90N-1 BSM90C-1 or / / E4 15 GBSM90-MRP (1) BSM90N-1 BSM90C-1 or / / E4 20 GBSM90-MRP (2) BSM90N-all BSM90C / / E4 22 GBSM90-MRP (1) BSM90N-all BSM90C / / E4 33 GBSM100-MRP120-3 (2) BSM100N-all BSM100C-all / / E4 15 GBSM100-MRP120-5 (2) BSM100N-1 or -2 BSM100C / / E4 15 GBSM100-MRP155-5 (2) BSM100N-3 or -4 BSM100C-5 or / / E4 22 GBSM100-MRP (2) BSM100N-1 BSM100C-1or-2or / / E4 22 (1) Max Backlash 12 arc-min (2) Max Backlash 10 arc-min Ap'x. Weight (Lbs.) Gearhead L2 L3 D1 D2 D stage stage stage stage stage stage stage stage stage stage 225 NOTES: Gearhead is adapted to mate to specified BSM motor only

225 DC Servo Servo 3 thru 50 lb-in Torque (0.3 thru 5.6 Nm) HVAC Applications: X-Y tables, converting equipment, coil winders, factory automation, packaging, material handling, automated testing, insertion, metering, bonders, label equipment, assembly equipment, textile, and others. Farm Duty Cont. Stall Torque (Lb-In) Cont. Stall Amps Nominal Bus Volts Features: High continuous duty ratings and include an insulation system with non-hygroscopic polyester high temperature class H varnish for dependability. Uses premium 200 C moisture resistant, multi-coated copper wire for reliability. Standard mountings are designed for world-wide acceptance. Rated Speed () Inertia (Lb-In-Sec 2 ) (3) NOTE: (1) Leadwires 18 inches long. (2) have 6 pin MS connector. (3) have US keyways. Tachometers have tach voltage constant of 7 V/k. (4) All units have MS connectors. Encoders are differential line drivers, 1000 ppr, A/B & Z channels, +5Vdc. (5) have metric keyways. Tachometers have tach voltage constant of 9.5 V/k. All units have 9 pin MS connector. Order mating connector or cable assemblies as shown below MT-2250-BCYAN (1) 495 E MT-2250-BCYCN (2) 561 E MT-3353-BLYAN (1) 561 E MT-3363-BLYAN (1) 626 E MT-3363-BLYCN (2) 692 E MT-4070-BLYCE (2) 922 E MT-4090-BLYCE (2) 982 E4 With Tachometers and Encoders (3)(4) MTE-2250-BCBCN 1115 E MTE-3363-BLBCN 1246 E MTE-4070-BLBCE 1475 E MTE-4090-BLBCE 1536 E4 With Tachometers and Metric Mounting (5) MT-4525-BTYCN 976 E MT-4525-DTYCN 976 E MT-4535-ATYCN 1052 E MT-4535-BTYCN 1052 E MT-4535-CTYCN 1052 E MT-4545-ATYCN 1165 E MT-4545-BTYCN 1165 E MT-4545-CTYCN 1165 E4 Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz DC Servo Cables Type Length Ft/(m) Cable with Connector Cable Assembly No. Connector No. Connector Only No. Pins Inverter/Vector & Controls MT-2250 MT-3353/MT-3363 MT-4070/MT-4090 MT-4525/MT-4535/MT Tach Only 20(6.1) CBL061SP-AF 157 E8 MSCF 6 57 E8 20(6.1) CBL061SP-BI 207 E8 MSCI 9 57 E8 Servo -Tach-Encoder MTE-2250 MTE-3353/MTE (6.1) CBL061SC-GN 207 E8 MSCN E8 MTE-4070/MTE (6.1) CBL061SC-GP 207 E8 MSCP E8 DC 225

226 HVAC Farm Duty Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz DC Servo Control Design Specifications One or two axis 5 Amps continuous 50v & 100v Bus Direct 115 Vac Velocity/current configuration Standard ±10 Vdc input command Output Ratings Input Ratings Control Spec Feedback Adjustments Ambient Conditions Indicators Status Logic power Excess current Surge current Voltage error Over temperature Environmental and Operating Conditions Input voltage single phase 115 VAC Input frequency-50 or 60 Hz Form factor 1.01 Duty - continuous Operating temperature 0-50 C Overload Current 200% for 2 seconds Output Current See ratings table Voltage 50 or 100 VDC depending on model Frequency 50 / 60 Hz Voltage single phase Phase One phase Control Method PWM PWM Frequency 20 KHz Speed Setting ±10VDC (Differential ±VDC) Form Factor 1.01 Min. Inductance 1.0 mh Frequency Response 2.5 khz Peak Current Adjustment 0-10 Amps Feedback Type Tachometer (when control operated in velocity configuration) Signal Adjust gain of input signal Tach Allows for variety of tach voltage gradients Continuous Current Protects the motor from overheating Peak Current Protects the motor from demagnetizing Balance Compensates for input signal drift Response Adjust velocity loop gain Temperature 0-50 C Servo 5 Amps VAC 60 Hz. 1 or 2 Axis Control Applications: X-Y tables, coil winders, automated test stands, metering bonders, factory automation, and several other general applications. Features: Totally enclosed stand alone one or two axes brush-type PWM servo control. The control can be removed from the carton and be operational within 10 minutes. It is fully protected, and has individual adjustments for RMS and peak current, balance, response, gain and tachometer. It will power DC servo motors providing up to 5 amps continuous, 10 amps peak. Protective Features Over/under voltage Over temperature Excess/surge current Short circuit protection Loss of logic voltage Inverter/Vector & Controls Servo Input Volts Output Bus Volts Continuous Output Amps Controls of TSD U 919 E TSD U 1433 E TSD U 994 E TSD U 1583 E3 NOTE: Control supplies 5 amps continuous, 10 amps peak. Dimensions in/(mm) DC 226 Height Outside Width Depth Mounting Height Ap x Width 1 Axis 2 Axis 12/(304.8) 4.5/(114.3) 7.5/(190.5) 11.3/(288) 2.5/(63.5) For additional servo motors, controls and accessories, visit

227 Subfractional Permanent Magnet DC - TENV, Rigid Base 1/50 thru 1/4 DC & Controls Applications: General purpose including conveyors, material handling equipment and packaging machinery. HVAC Features: High quality ball bearing motors with precision machined die cast aluminum or steel housings. Dynamically balanced for smooth, vibration-free operation. Farm Duty Input Output Base Speed Voltage Direct Current Armature SCR Drive Permanent Magnet - TENV and TEFC, Rigid Base with C-Face Amperage Armature 1/ AP DS 2308P-ABP-0 4 1/ AP DS 2314P-ABP-0 5 1/ AP DS 2318P-ABP-0 6 1/ AP DS 74-AHP / AP DS 74-AHP / AP DS 2318P-ABP-0 5 1/ AP DS 74-AHP / AP DS 74-AHP-0 11 NOTE: Supplied with type SJO, three foot 18/3 AWG grounded cord. See notes on pages 8 and 9, and inside back flap. 1/4 thru 5 56C thru 1810ATC Applications: Conveyors, mixers, packaging machinery. Type & Gear Style Features: C-face with removable base. Tach adaptable. Class F insulation, double sealed ball bearings. 20:1 constant torque speed range. UL and CSA recognized. 3300P motors are TENV, all others are TEFC. No dual mounting base holes on 33P type. Definite Purpose Brake 200 & 575 Volt IEC Base Speed Voltage D.C. Amperage Arm. Field Arm. Field 1/ C 90 PM 2.5 PM CDP K 3320P 24 1/ C 180 PM 1.3 PM CDP K 3320P 24 1/ C 90 PM 3.2 PM CDP K 3327P 27 1/ C 180 PM 1.6 PM CDP K 3327P 27 1/ C 90 PM 4.8 PM CDP K 3336P 32 1/ C 180 PM 2.5 PM CDP K 3336P 31 1/ C 90 PM 5.0 PM CDP K 3327P 26 3/ C 90 PM 7.6 PM CDP K 3428P 18 3/ C 180 PM 3.7 PM CDP K 3428P 39 3/ C 90 PM 7.5 PM CDP K 3420P C 90 PM 10.0 PM CDP K 3435P C 180 PM 5.0 PM CDP K 3435P C 90 PM 9.7 PM CDP K 3428P C 180 PM 4.9 PM CDP K 3428P / TC 180 PM 7.7 PM CDP L1 3536P / TC 180 PM 7.0 PM CDP L1 3524P TC 180 PM 9.6 PM CDP L1 3548P TC 180 PM 10.0 PM CDP L1 3536P TC 180 PM 14.0 PM CDP L1 3649P C 180 PM 14.0 PM CDP L1 3649P ATC 180 PM 24.5 PM CDP L1 3681P 153 NOTE: See Tach Generators on page 237 and Mounting Kits on page 238. See notes on pages 8 and 9, and inside back flap. Type 50 Hertz Inverter/Vector & Controls Servo DC 227

228 HVAC Farm Duty Integral DC Tach Permanent Magnet SCR Drive - TENV and TEFC, Rigid Base with C-Face DC & Controls 1/4 thru 5 56C thru 1810ATC Applications: Conveyors and metering pumps (precise speed regulation). Features: Provides an integral 50 VDC per 1000 precision tachometer for closed loop drive system. Class F insulation. 20:1 constant torque speed range with Type K control. 3300P motors are TENV, all others are TEFC. Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz Inverter/Vector & Controls Servo DC 228 Base Speed Voltage D.C. Explosion Proof Permanent Magnet SCR Drive - TEFC, Rigid Base with C-Face Amperage Arm. Field Arm. Field 1/ C 90 PM 2.5 PM CDPT K 3320P 27 1/ C 180 PM 1.3 PM CDPT K 3320P 27 1/ C 90 PM 3.2 PM CDPT K 3327P 30 1/ C 180 PM 1.6 PM CDPT K 3327P 30 1/ C 90 PM 4.8 PM CDPT K 3336P 35 1/ C 180 PM 2.5 PM CDPT K 3336P 36 3/ C 90 PM 7.6 PM CDPT K 3428P 44 3/ C 180 PM 3.7 PM CDPT K 3428P C 90 PM 10.0 PM CDPT K 3435P C 180 PM 5.0 PM CDPT K 3435P / TC 180 PM 7.7 PM CDPT L1 3536P TC 180 PM 9.6 PM CDPT L1 3548P ATC 180 PM 14.0 PM CDPT L1 3649P ATC 180 PM 24.5 PM CDPT L1 3681P 161 Base Speed Voltage D.C. 1/4 thru 1 1/2 56C thru 145TC Applications: Conveyors, feeders, and pumps (adjustable speed and constant torque for hazardous locations). Features: C-Face with welded on base. 20:1 constant torque speed range. UL and CSA. Class I, Group D; Class II, Group F & G. T3C. Thermostat and explosion proof conduit box included. Not tach adaptable. Amperage Arm. Field Arm. Field 1/ C 90 PM 2.7 PM CDPX K X3413P 38 1/ C 180 PM 1.3 PM CDPX K X3413P 38 1/ C 90 PM 3.6 PM CDPX K X3420P 42 1/ C 180 PM 1.7 PM CDPX K X3420P 44 1/ C 90 PM 5.2 PM CDPX K X3428P 46 1/ C 180 PM 2.5 PM CDPX K X3428P 46 3/ C 90 PM 7.0 PM CDPX K X3435P 51 3/ C 180 PM 3.5 PM CDPX K X3435P C 90 PM 9.6 PM CDPX K X3536P C 180 PM 4.9 PM CDPX K X3536P / TC 180 PM 7.1 PM CDPX L1 X3548P 81 NOTE: 8 Class I, Group D, Class II, Group F & G. T3C. See notes on pages 8 and 9, and inside back flap. Type Type

229 Washdown Duty Permanent Magnet SCR Drive - TENV and TEFC, Rigid Base with C-Face Base Speed Voltage D.C. DC & Controls 1/4 thru 5 56C thru 1810ATC Applications: Food processing conveyors and feeders exposed to high pressure wash down. Features: Moisture sealant on bolt heads between frame and endplates, neoprene gasketed conduit box. Double sealed ball bearings. Forsheda running contact v-ring slinger. Stainless steel shaft. Electrostatic epoxy paint coating. Class F insulation. 20:1 constant torque speed range. Tach adaptable. 3300P motors are TENV, all others are TEFC. Amperage Arm. Field Arm. Field 1/ C 90 PM 2.5 PM CDPWD K 3320P 25 1/ C 180 PM 1.3 PM CDPWD K 3320P 24 1/ C 90 PM 3.2 PM CDPWD K 3327P 27 1/ C 180 PM 1.6 PM CDPWD K 3327P 27 1/ C 90 PM 4.8 PM CDPWD K 3336P 32 1/ C 180 PM 2.5 PM CDPWD K 3336P 32 3/ C 90 PM 7.6 PM CDPWD K 3428P 38 3/ C 180 PM 3.7 PM CDPWD K 3428P C 90 PM 10.0 PM CDPWD K 3435P C 180 PM 5.0 PM CDPWD K 3435P / TC 180 PM 7.7 PM CDPWD L1 3536P TC 180 PM 9.6 PM CDPWD L1 3548P TC 180 PM 14.0 PM CDPWD L1 3649P ATC 180 PM 24.5 PM CDPWD L1 3681P 157 NOTE: See Tach Generators on page 237. Mounting kits on page 238. See notes on pages 8 and 9, and inside back flap. Type HVAC Farm Duty Definite Purpose Brake 200 & 575 Volt IEC Paint Free Washdown Duty Permanent Magnet SCR Drive 1/4 thru 1 56C thru 1810ATC Applications: Food processing, packaging exposed to high pressure washdown with caustic solutions. Features: Class F insulation; 20:1 constant torque speed range. Moisture resistant 200 C magnet wire. Sealed ball bearings with moisture resistant grease. Contact lip seals on shaft extensions. Neoprene gaskets. Special processed endplates. 300 series stainless steel motor frame, base, shaft and hardware. No exterior paint. Tropicalized. Not tach adaptable. 50 Hertz Inverter/Vector & Controls Base Speed Voltage D.C. Amperage Arm. Field Arm. Field 1/ C 90 PM 2.7 PM CDPSWD K 3413P 29 1/ C 180 PM 1.3 PM CDPSWD K 3413P 28 1/ C 90 PM 5.2 PM CDPSWD K 3428P 37 1/ C 180 PM 2.5 PM CDPSWD K 3428P C 90 PM 9.6 PM CDPSWD K 3536P C 180 PM 4.9 PM CDPSWD K 3536P 63 Type Servo DC 229

230 HVAC Farm Duty Metric Flange Permanent Magnet SCR Drive, and Face Mount DC & Controls 0.2 thru 3.7 IEC D63 thru D112D Applications: Metric SCR Drive replacement. Features: Metric Flange or C-Face per IEC Standards. Bolt on non-metric base. Class F insulation. Tach adaptable except type 135P. 20:1 constant torque speed range. Type 135P and 3300P motors are TENV; all others are TEFC. Conforms to IEC Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz Inverter/Vector & Controls kw/ Base Speed Voltage D.C. Amperage Arm. Field Arm. Field B5 Flange.15/ D63D 180 PM 1.1 PM VP7424D 293 DS 135P 5.18/ D71D 180 PM 1.3 PM VP3311D 428 K 3320P 24.25/ D71D 180 PM 1.6 PM VP3316D 450 K 3327P 26.37/ D71D 180 PM 2.5 PM VP3326D 505 K 3336P 31.37/ D71D 180 PM 2.5 PM VP3428D 476 K 3416P 32.57/ D80D 180 PM 3.7 PM VP3436D 606 K 3428P 41.57/ D80D 180 PM 3.6 PM VP3439D 539 K 3420P 40.75/ D80D 180 PM 5.0 PM VP3455D 736 K 3435P 22.75/ D80D 180 PM 5.1 PM VP3458D 606 K 3428P / D90D 180 PM 7.7 PM VP3575D 1388 L1 3536P / D90D 180 PM 7.7 PM VP3468D 670 L1 3432P / D90D 180 PM 9.6 PM VP3585D 1648 L1 3548P / D90D 180 PM 10.0 PM VP3588D 1388 L1 3536P / D112D 180 PM 14.0 PM VP3603D 2042 L1 3649P / D112D 180 PM 24.5 PM VP3605D 3454 L1 3681P 165 B14 Face.15/ D63C 180 PM 1.1 PM VP DS 135P 5.18/ D71C 180 PM 1.4 PM VP K 3410P 30.25/ D71C 180 PM 1.7 PM VP K 3413P 31.37/ D71C 180 PM 2.5 PM VP K 3420P 37.56/ D80C 180 PM 3.7 PM VP K 3428P 39.75/ D80C 180 PM 5.0 PM VP K 3435P / D90C 180 PM 7.7 PM VP L1 3536P / D90C 180 PM 9.6 PM VP L1 3548P 80 NOTE: Above motors D71 and larger with B5 flange, fitted with oil seal. numbers VP7424D and VP are not tach adaptable. Tach Generators are shown on page 237. Tach Mounting Kits are shown on page 238. See notes on pages 8 and 9, and inside back flap. Type Servo DC 230

231 Low Voltage Permanent Magnet - TENV and TEFC 1/4 thru 1 56C DC & Controls Applications: Battery operation for portable pumps, fans, augers, winches and lifts. HVAC Features: C-face, Class F insulation, double sealed ball bearings. Top-mounted terminal studs for power connection on ratings 40-amps and up. Not tach adaptable. 1/4-1/2 are TENV, 2/4-1 are TEFC. Farm Duty Base Speed Voltage D.C. Amperage 1/ C CDP3410-V K 3416P 32 1/ C CDP3410-V K 3416P 32 1/ C CDP3420-V K 3416P 32 1/ C CDP3420-V K 3416P 32 1/ C CDP3430-V K 3420P 33 1/ C CDP3430-V K 3424P 35 3/ C CDP3440-V K 3430P 42 3/ C CDP3440-V K 3424P C CDP3445-V K 3435P C CDP3445-V K 3435P 46 Type Definite Purpose Brake 200 & 575 Volt DC Power - TEFC, Rigid Base 1/3 thru 1 1/2 56 thru 184 Applications: Cranes, hoists, conveyors, augers and marine duty DC applications. Powered from generators or batteries. Features: 20% Compound Wound. Weather proof, meets IEEE45 specifications. Suitable for mounting in any position. Continuous duty. Easy access brushes. Not tach adaptable. IEC 50 Hertz Speed Rated Current 115 VDC 1/ D K 3413D 23 1/ D K 3420D 29 3/ D K 3428D D K 3535D VDC 1/ D K 3513D 32 1/ D K 3420D 29 3/ D K 3428D D K 3535D / D L1 3636D 84 NOTE: Not for SCR control applications. Base welded on 3513D type only. Not tach adaptable. See notes on pages 8 and 9, and inside back flap. Type Inverter/Vector & Controls Servo DC 231

232 HVAC Farm Duty Definite Purpose Shunt Wound SCR Drive - TEFC and Explosion-Proof C-Face with Bolt on Base Base Speed Voltage D.C. DC & Controls 1/4 thru 10 56C thru 256UC Applications: Conveyors, printing, textile equipment, machine tools (adjustable speeds with constant torque). Features: TEFC enclosure, shunt wound, Class F insulation. Designed for use with TYPE K SCR control, 20:1 constant torque speed range (except where noted). C-face and removable base (1) (except on explosion proof models). 182 and larger have a thermostat (normally closed contracts) on the field winding. No dual mounting base holes on 35D, 75D or 91D type. Amperage Arm. Field Arm. Field (3) Type Brake 200 & 575 Volt IEC 50 Hertz Inverter/Vector & Controls Servo 1/ C / CD K 3413D 23 1/ C / CD K 3413D 24 1/ C / CD K 3413D 24 1/ C / CD5333 (1) 655 K 3513D 29 1/ C / CD K 3420D 29 1/ C / CD K 3420D 29 1/ C / CD K 3520D 38 3/ C / CD K 3428D 34 3/ C / CD K 3428D 34 3/ C / CD K 3528D C / CD K 3535D C / CD K 3535D C / CD L1 3623D C / CD L1 3623D / C / CD L1 3636D C / CD L1 3646D C / CD L1 7528D TC / CD L1 3668D C / CD L1 7544D C / CD L1 7556D UC / CD L1 9154D / UC / CD L1 9154D UC / CD L1 9168D 347 Explosion-Proof - Continuous Duty - Class I, Group D & Class II, Group F & G S.F. 1/ CZ / /1.1 CDX1850 (2) 1697 L1 X3623D 103 3/ CZ / /1.1 CDX1875 (2) 2248 L1 X3623D CZ / /.50 CDX2001 (2) 2798 L1 X3623D C / /.50 CDX L1 X3623D / C / /.50 CDX L1 X3636D C / /.8 CDX7200 (2) 3453 L1 X3646D CY* / /.8 CDX7513 (2) 5718 L1 X7544D 259 NOTE: See Tach Generators on page 237 and Mounting Kits on page 238. Tach Mounting Kits are not available for explosion-proof motors. (1) Base welded on type 3513D only. (2) Refers to shaft and/or face mounting dimensions only. Base mounting dimensions and shaft height differ from frames shown. See the Baldor Drives for details. (3) Field amps for high voltage connection. 3:1 Speed range with constant torque. Explosion-proof ratings UL and CSA, Class I, Group D & Class II, Group F & G, will not exceed surface temperature of 165 C, equivalent to Code T3B. See notes on pages 8 and 9, and inside back flap. * F2 Mount DC 232

233 SCR Drive Shunt and Stabilized Shunt Wound - DPFG, Self Ventilated, Rigid Base DC & Controls 5 thru AT thru 506AT Applications: Conveyors, plastic extruders, packaging machinery and other constant torque applications for DC SCR motors. Features: Includes thermostat on interpole. Class F insulation system resistant to dirt, carbon, dust and moisture. High dielectric stability. Low moment of inertia armature for fast response. Constant pressure brush springs and longer brushes for reduced maintenance. Includes grease fittings and reliefs for bearing maintenance. Power code C and D or M-G sets. Maximum by field weakening. Provisions for tach mounting. (See tach mounting kits on page 236). May be converted to blower ventilated (DPBV) for extended constant torque speed range. HVAC Farm Duty Definite Purpose Base/Max Speed (5) Voltage D.C. Amperage Arm. Field Arm. Field (4) Only (6) /2300 L186AT / D2005P 3298 N2 184 TKP1836XP FVB /2300 L186AT / D5005P 3298 N2 178 TKP1836XP FVB /2 1750/ AT / D2007P 3979 N2 242 TKP1836XP FVB /2 1750/ AT / D5007P 3979 N2 244 TKP1836XP FVB / AT / D2010P 4534 N2 260 TKP1836XP FVB / AT / D5010P 4534 N2 264 TKP1836XP FVB / AT / D2015P 5455 N2 376 TKP1836XP FVB / AT / D5015P 5455 N2 382 TKP1836XP FVB / AT / D2020P 6254 N2 426 TKP1836XP FVB / AT / D5020P 6254 N2 424 TKP1836XP FVB / AT / D2025P 7381 N2 636 TKP1836XP FVB / AT / D5025P 7381 N2 520 TKP1836XP FVB / AT / D2030P 8122 N2 598 TKP1836XP FVB / AT / D5030P 8122 N2 600 TKP1836XP FVB / AT / D5040P N2 844 TKP1836XP FVB / AT / D5050P N2 836 TKP1836XP FVB / AT / D5060P N2 823 TKP1836XP FVB / AT / D5075P N2 950 TKP1836XP FVB / AT / D50100P N TKP1836XP FVB / AT / D50125P N TKP400XP FVB / AT / D50150P N TKP400XP FVB / AT / D50200P N TKP500XP FVB / AT / D50250P N TKP500XP FVB8500 NOTE: (4) Field amps are for 150V connection on 240VDC motors; 300V connection on 500VDC motors. 360, 400 & 500 frames are 4 pole stabilized shunt, others are 2 pole shunt. (5) DPFG enclosure is self-ventilated. Speed can be reduced to approximately 60% of base speed with constant torque. See performance data in CA608 catalog for specific speed-torque curves. Separate blower can be used to increase operating range below 60% of base speed. (6) Does not include price of blower. See page 236 for pricing. (7) Does not include weight of blower. See page 236 for weights. See notes on pages 8 and 9, and inside back flap. 180 frame motors are supplied without external conduit box, see online layout drawing for details. (7) XPY Tach Kit Blower Brake 200 & 575 Volt IEC 50 Hertz Inverter/Vector & Controls DC Servo 233

234 HVAC Farm Duty Definite Purpose Brake 200 & 575 Volt IEC SCR Drive Shunt and Stabilized Shunt Wound DPBV Enclosure - Rigid Base Base/Max Speed Voltage D.C. DC & Controls 40 thru AT thru 5010AT Applications: Conveyors, plastic extruders, packaging machinery and other constant torque applications for DC SCR motors. Features: Includes thermostat on interpole. Class F insulation system resistant to dirt, carton, dust and moisture. High dielectric stability. Low moment of inertia armature for fast response. Constant pressure brush springs and longer brushes for reduced maintenance. Includes grease fittings and reliefs for bearing maintenance. Power code C or M-G sets. Maximum by field weakening. Provisions for tach mounting. (See tach kits on page 236). Blower-ventilated, includes filter. Amperage Arm. Field Arm. Field (4) NOTE: (4) Field amps are for 150V connection on 240VDC motors; 300V connection on 500VDC motors. 360 through 500 frames are 4 pole stabilized shunt, others are 2 pole shunt. Tach mounting kits on page 236. w/blower & Filter / AT / D2040P-BV N2 890 TKP1836XP / AT / D5040P-BV N2 902 TKP1836XP / AT / D2050P-BV N2 902 TKP1836XP / AT / D5050P-BV N2 897 TKP1836XP / AT / D2060P-BV N TKP1836XP / AT / D5060P-BV N2 872 TKP1836XP / AT / D2075P-BV N TKP1836XP / AT / D5075P-BV N TKP1836XP / AT / D50100P-BV N TKP1836XP / AT / D50125P-BV N TKP1836XP / AT / D50150P-BV N TKP400XP / AT / D50200P-BV N TKP400XP / AT / D50250P-BV N TKP500XP / AT / D50300P-BV N TKP500XP / AT / D50400P-BV N TKP5006XP / AT / D50500P-BV N TKP500XP XPY Tach Kit 50 Hertz Inverter/Vector & Controls Servo DC 234 SCR Drive 240V Armature - 240V Field Shunt Wound DPFG - Self-Ventilated Rigid Base and C-Face Base/Max Speed Voltage D.C. 3 thru 15 L186ATC thru 258ATC Applications: Conveyors, plastic extruders, packaging machinery and other constant torque applications for DC SCR motors. Features: Includes thermostat on interpole. Class F insulation system resistant to dirt, carton, dust and moisture. High dielectric stability. Low moment of inertia armature for fast response. Constant pressure brush springs and longer brushes for reduced maintenance. Includes grease fittings and reliefs for bearing maintenance. Power code C or M-G sets. Maximum by field weakening. Amperage Arm. Field Arm. Field (8) (6) NOTE: (6) Does not include price of blower and filter. See page 236 for pricing. (7) Does not include weight of blower and filter. See page 236 for weights. Tach mounting kits on page 236. (8) Field amps for 240VDC connection. See notes on pages 8 and 9, and inside back flap. 180 frame motors are supplied without external conduit box, see online layout drawing for details. (7) XPY Tach Kit Blower /2300 L186ATC / CD2003P N2 186 TKP1836XP FVB /2300 L186ATC / CD2005P N2 188 TKP1836XP FVB /2 1750/ ATC / CD2007P N2 219 TKP1836XP FVB / ATC / CD2010P N2 272 TKP1836XP FVB / ATC / CD2015P N2 408 TKP1836XP FVB3250

235 Shunt Wound SCR Drive - TEFC, Rigid Base DC & Controls 5 thru AT THRU 328AT Applications: Conveyors and packaging machinery. Features: Includes thermostat on interpole, grease fittings and reliefs. Class F insulation system. Constant pressure brush springs and precision brush holders. Provisions for tach mounting ( See tach mounting kits page 236). HVAC Farm Duty Base/Max Speed / AT / D2505P 4682 N2 228 N/A / AT / D5505P 4993 N2 230 N/A 7 1/2 1750/ AT / D2507P 5664 N2 316 TKP2136XPT 7 1/2 1750/ AT / D5507P 5664 N2 286 TKP2136XPT / AT / D2510P 6467 N2 450 TKP2136XPT / AT / D5510P 6467 N2 456 TKP2136XPT / AT / D2515P 8345 N2 599 TKP2136XPT / AT / D5515P 8345 N2 599 TKP2136XPT / AT / D2520P 9585 N2 884 TKP2136XPT / AT / D5520P 9585 N2 920 TKP2136XPT / AT / D2525P N2 872 TKP2136XPT / AT / D5525P N2 894 TKP2136XPT NOTE: (4) Field amps are for 150V connection on 240VDC motors; 300V connection on 500VDC motors. Tach mounting kits on page frame motors are supplied without external conduit box, see online layout drawing for details. Lifting Magnet Generators Voltage D.C. Amperage Arm. Field Arm. Field (4) Only 5 thru 40 kw 1810AT thru 329AT XPY Tach Kit Applications: Crane mounted lifting magnets for recyclers and steel mills. Features: Heavy duty steel frame. Cast iron endplates. Class H insulation with Class F temperature rise. Precision brush holders. Constant force brush springs. Double sealed ball bearings. Compound wound with drooping voltage characteristics. DPFG enclosure. Weather resistant paint. F-2 conduit box. CDMG generators have C-face and base mounting for hydraulic pump or PTO mounting. Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz kw Base Speed Voltage D.C. Amperage Arm. Field Arm. Field AT DMG N / AT DMG N AT DMG N ATC CDMG N AT DMG N ATC CDMG N AT DMG N ATC CDMG N AT DMG N ATC CDMG N AT DMG N ATC CDMG N AT DMG N NOTE: Field control rheostat and meters are not included in price or available from Baldor. See notes on pages 8 and 9, and inside back flap. Field Control Rheostat Ohms Amp Max. Inverter/Vector & Controls Servo DC 235

236 HVAC Farm Duty DC & Controls Tach Mounting Kits and Cooling Blowers for DC Integral Applications: Allows addition of DC, AC and digital tachometers to large DC motors for closed-loop operation. Features: Tach mounting kits supply adapter, coupling, accessory shaft and mounting hardware. Allows mounting to 8.5 inch accessory face on most large DC motors. Definite Purpose Brake 200 & 575 Volt IEC Tach Mounting Kits for DC Integral No. Ending With P Tach Type XPYII XPY, DPY BTG1000 XC42 or XC46 ENC00NV ENCODER NCS PANCAKE AC PANCAKE Enclosure 180/360 DPFG, DPBV TKP1836XP 604 A /360 TEFC TKP2136XPT 604 A DPFG, DPBV TKP400XP 604 A DPFG, DPBV TKP500XP 604 A /360 DPFG, DPBV TKP2136XC 844 A DPFG, DPBV TKP500XC 844 A /360 DPFG, DPBV TKP1836ENC 460 A DPFG, DPBV TKP400ENC 460 A DPFG, DPBV TKP500ENC 460 A /360 DPFG, DPBV TKP2136NC 36 A DPFG, DPBV TKP400NC 36 A DPFG, DPBV TKP500NC 36 A /360 DPFG, DPBV TKP2136AC 36 A DPFG, DPBV TKP400AC 36 A DPFG, DPBV TKP500AC 36 A Hertz Inverter/Vector & Controls Servo DC Blower and Mounting Kits for DC Integral No. Ending With P Blower Power Blower Size Blower and Mounting Kit 180 FVB PH LM A FVB PH LM A FVB PH LM A FVB PH LM A FVB PH LM A FVB PH LM A FVB PH LM A FVB95010 (A) 3 PH LM A8 122 Filter and Hardware for Above Blowers 180, 210, 250 FLT (B) - LM A FLT LM A ,360,400 FLT LM A FLT LM A8 9 NOTE: (A) Includes Blower and Filter. (B) Also used with FVB

237 Tach Generators DC, AC and Digital Output DC & Controls Applications: Speed feedback for controls (encoders also offer position feedback). Features: Ball bearing construction, standard mounting flanges and/or feet. HVAC Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz Inverter/Vector & Controls DC Servo Farm Duty Generator Type Voltage XPY Flange Mount (DC) 30AFL-O 50VDC BTG DS 7 XPYII 100VDC PTG100XPS 912 N5 10 XPY 100VDC PTG100XP 694 N5 3 XPYII 50VDC PTG50XPS 912 N5 8 XPY 50VDC PTG50XP 694 N5 3 XPY Washdown Flange Mount (DC) XPYII 100VDC PTGWD100XPS 971 N5 9 XPYII 50VDC PTGWD50XPS 971 N5 10 Encoder Based Digital PY Flange Mount DPY 1024PPR PTG1024LD (F) 1144 N5 1 Electrically Isolated Encoder E-ACC 1024PPR ENC00NV (C) (F) 1245 E8 2 Metric Flange Mount (DC) XPY 60VDC PTG60XP-M (D) 694 N5 8 XPYII 60VDC PTG60XPS-M (D) 912 N5 5 Foot Mount (DC) XPY 100VDC PFTG100XP 694 N5 6 XPY 50VDC PFTG50XP 694 N5 6 Foot Mount with Face (DC) XC42 100VDC PFTG42100X 1727 N5 33 XC42 50VDC PFTG4250XC 1765 N5 32 XC46 100VDC PFTG46100X 3036 N5 43 XC46 50VDC PFTG4650XC 3036 N5 44 Pancake Mount (AC & DC) AC 45/90VAC PTG4590AC (E) ** 843 N5 9 NCS 50VDC PTG50NC (E) ** 1259 N5 8 NOTE: Flange mounted tachs require tach adapters shown on pages 236 & 238. XPY tachs have UL listing, file number E109527, CSA file number LR , XPYII tachs are pending approval. (C) Electrically isolated encoder & kit: Mounts to Charlotte DC motors using appropriate adapter shown on page 236 may eliminate the need for EXB00801 isolated encoder feedback board. (D) Requires adapter for metric flange tach. Will not mount on adapters for PY flanges. (E) Does not mount to TEFC. See catalog MN605 for details. Will only mount to DPFG and DPBV motors on pages 233 & 234 using adapters shown on page 236. (F) See page 167 for cables. 237

238 HVAC Farm Duty Field Conversion Tach Mounting Kits for Permanent Magnet and Shunt Wound DC & Controls For PY Flange mounted BTG1000, XPY, XPYII and DPY tachometers Complete kits consisting of fan cover (except TK3300), shaft extension coupling and tach adapter bracket with miscellaneous hardware. If you prefer, the conversion can be made by Baldor Mod Express. Tach kits will not work with Explosion Proof (CDPX or CDX). See PY flange mount tachs shown on page. Definite Purpose Brake 200 & 575 Volt IEC Fractional Horsepower DC Speed Controls for PMDC Baldor Type Kit 3300P TK A D/P TK A D/P TK A D TK A P TK3600PM 286 A D TK A D TK A8 23 For HPU hall effect pick-up 3300P TK3300-HPU 65 A P/D TK3400-HPU 75 A8 1 1/15 thru 1/4 115 VAC Single Phase 50/60 Hz. Applications: Conveyors, machine tools and other applications requiring adjustable speed. Features: Simple DC motor control with built-in circuit breaker, center lock reversing switch (center off), on/off switch, 7 foot SJO oil resistant cord, and variable voltage transformer for manual speed adjustment. 1 enclosure is standard. CSA list file # LR Hertz Inverter/Vector & Controls Max Mult Ap x Amp Capacity Input Voltage 1/15 BC E VAC 1/8 BC E VAC 1/4 BC E VAC Servo DC 238

239 1 Enclosed DC Controls for PMDC and Shunt Wound DC & Controls 1/100 thru 2 115/230 VAC Single Phase 50/60 Hz. Applications: General purpose industrial use with permanent magnet or shunt wound DC motors. HVAC BC140 ENCLOSED ( 1) Range Features: SCR controls have a free-wheeling diode and feature adjustable accel, decel, current limit, IR comp, min. and max speed pots to match applications. The anti-demag feature protects PM motors and helps protect the SCR power bridge against direct shorts. The controls have US and Canadian UL component recognition. 1/100-1/3 BC E /50-3/4 BC E /100-2 (1) BC E /230 1/100-2 (1) BC140-FBR 408 E /230 NOTE: (1) 1 at 115V and 2 at 230V requires BC143 heatsink kit. See page 243 for features. FBR=Forward/Brake/Reverse. DC Control Accessories Description BC24-LF Ac Line Filter for use with CE Applications 58 E9 1 BC143 External Heatsink Kit (BC140, BC140-FBR, BC141, BC142, BC204) 56 E9 2 BC144 Forward-Brake-Reverse Switch Kit for BC E9 1 BC145 Signal Isolator Board 167 E9 1 BC146 Current Sensing Relay/Overload Protector 108 E9 1 BC147 Barrier Terminal Board (BC141 and BC142) 22 E9 1 BC148 Replacement Potentiometer Kit (5K ohm) 9 E9 1 BC149 Knob and Dial Kit 10 E9 1 BC151 Electronic Speed Potentiometer 66 E9 1 BC152 Barrier Terminal Board With Signal Isolator (BC141 and BC142) 153 E9 1 BC218 DIN-rail mounting kit for BC141, BC142 or BC E9 1 NOTE: BC24-LF is an AC line filter required for applications where CE is required if the control is not filtered elsewhere in the application. This filter may be used on most 115 or 230 VAC, single phase applications where CE is required. Ap x Lbs. Input Voltage Farm Duty Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz Inverter/Vector & Controls DC Servo 239

240 HVAC Farm Duty Definite Purpose Brake 200 & 575 Volt IEC Chassis Mount DC Controls BC141 / BC142 Range NOTE: Above controls include 5k speed potentiometer. (2) at 115 Volts and 2-3 at 230 Volts, requires BC143 Heatsink kit. BC155 Includes integral heatsink. Please refer to page 244 for features. Plug-in Horsepower Resistor and Fuse Kit DC & Controls 1/100 thru VAC Single Phase 50/60 Hz. 1/50 thru VAC Single Phase 50/60 Hz. Applications: General purpose industrial use with permanent magnet or shunt wound DC motors. Features: Chassis-mount SCR controls have a free-wheeling diode and feature adjustable accel, decel, current limit, IR comp, min and max speed pots to match applications. The anti-demag feature protects PM motors and helps protect the SCR power bride against direct shorts. The controls have US and Canadian UL component recognition. Ap x Lbs. Input Voltage (1Ph,50/60 Hz) 1/ /2 (2) BC E /100-3 (2) BC E / /2 (2) BC E /230 1/50-3 (2) 5 BC E A Plug-in Horsepower Resistor and armature fuse must be ordered and installed in BC138, BC139, BC140, BC140-FBR, BC141 and BC142. These should be selected based on the motor s rated current. The price of the resistor and fuse is included in the BC138, BC139, BC140, BC140-FBR, BC141 and BC142 list price. See selection below for catalog number. Spare resistor kits are available for $5.00 list, E9 multiplier. 50 Hertz Inverter/Vector & Controls Servo DC Plug-In Armature Voltage Resistor Resistance Ap x DC DC Fuse Rating V 180V Value (Ohms) Current (Amps) For Armature 1/100 1/ BR /50 1/ BR /30 1/ BR /20 1/ BR /15 1/ BR /12 1/ BR /8 1/4 0.1 BR /6 1/3 0.1 BR /4 1/ BR /3 3/ BR / BR /4 1 1/ BR0015SP (3) 2 (3) 0.01 BR0010SP /2 (3) 3 (3) BR (4) NOTE: (3) External Heatsink required. (4) Also used with AC Line Fuse. For AC line fuse rating see manual. 240

241 4X DC Control and Accessories DC & Controls 1/4 thru 2 115/230 VAC Single Phase 50/60 Hz VAC Single Phase 50/60 Hz. Applications: Constant torque, new or replacement. Features: BC154, BCWD140 and BC160 are one-way controls with reversal by means of switching the armature leads (BCWD140 has a forward/brake/ reverse switch mounted). BC254 is a line regenerative SCR control that can drive the motor to a timed stop. BC354 is a PWM control that provides lowripple DC power to the motor allowing more when use with a 140 or 280 DCV motor. All offer a choice of armature or tachometer feedback and a speed or torque mode. No resistors are needed for these controls, current is jumper selectable. BC154, BC160, BC254 and BC354 are painted black and come with a start-stop switch. BCWD140 comes with white epoxy paint and also forward/ brake/reverse and run-jog switches. See page 243 for features. HVAC Farm Duty Definite Purpose Range Description Input Voltage / Max. 4X SCR (black) 1/4-2 BC V - 1, 230V E /230 3 BC V E X Washdown Duty SCR (white) 1/4-2 BCWD V - 1, 230V E /230 4X Washdown Duty Line Regen SCR (black) 1/8-2 BC V - 1, 230V - 2 (5) 538 E /230 4X Washdown Duty PWM DC (black) (6) 1/4-2 BC V - 1, 230V E /230 NOTE: (5) See page for BC254 accessories. (6) Output current is 7.5 amps; Output voltage is 140VDC for 115VAC input - 280VDC for 230VAC input. designed for these voltages will give the best performance. Input Voltage Brake 200 & 575 Volt IEC DC SCR Washdown Duty Control Accessories Description BC153 Electronic Forward-Dynamic Brake-Reverse Kit for BC154, BC E9 1 BC156 Mechanical Forward-Dynamic Brake-Reverse Switch for BC154, BC E9 1 BC157 Run/Jog switch for BC154 & BC160, BC E9 1 BC158 Auto/Manual Installation Kit for BC145 signal isolator for BC154, BC160, BC E9 1 BC159 AC Line Switch Kit for BC154, BCWD140, BC254, BC E Hertz Inverter/Vector & Controls DC Servo 241

242 HVAC Farm Duty Definite Purpose Brake 200 & 575 Volt Line Regenerative DC Controls and Accessories Range DC & Controls 1/4 thru 3 115/230 VAC Single Phase 50/60 Hz VAC Single Phase 50/60 Hz. Applications: Frequent start/stop/reverse applications or where controlled braking is required. Features: Single phase line regenerative open chassis control to operate permanent magnet or wound field DC motors. These line regen controls are ideal for applications with overhauling loads. In torque mode, it can be used for tensioning applications. Several accessory boards are available to further customize the control. Includes 5k speed potentiometer. See page 244 for features. Jumper selectable current settings. Description Input Voltage / Max. Line Regen SCR 1/4-1 1/2 BC V 3/4, 230V 1 1/2 396 E /230 1/8-2 (7) BC V 1, 230V E /230 1/4-2 BC V 1, 230V E /230 1/4-3 BC V 1 1/2, 230V E /230 5 BC V E X Washdown Duty Line Regen SCR 1/8-2 BC V - 1, 230V E /230 NOTE: (7) 1 at 115 volts and 2 at 230 volts requires BC143 heatsink kit. Input Voltage IEC 50 Hertz Inverter/Vector & Controls Servo Regenerative Control Accessories Description Accessories for BC200, BC201, BC202 and BC203 BC211 4 quadrant accel/decel board 128 E9 1 BC212 Bipolar signal isolator board 171 E9 1 BC214 BC202 expansion board kit. Required to add BC211 or BC212 to BC202 7 E9 1 Accessories for BC204 BC143 External Heatsink Kit 56 E9 2 BC215 Bipolar signal isolator board 79 E9 3 BC216 Multispeed board for BC E9 1 BC218 DIN rail mounting kit 27 E9 1 Accessories for BC254 BC245 Bipolar signal isolator for BC E9 1 BC253 Forward-Stop-Brake-Reverse Switch for BC E9 1 BC258 Auto-manual Switch for BC E9 1 BC259 AC Line Switch for BC E9 5 DC 242

243 Enclosed DC Control Specifications BC140 or DC & Controls Features BC138 BC139 BC140-FBR BC154 BC160 BCWD140 Enclosure X 4X 4X Washdown Control Type K K K K K K AC Line Input DC Armature Voltage Nominal Shunt Field Power Supply Voltage - DC 50/ /200 50/ /200 50/ / /200 50/ /200 Rated Horsepower Range 1/100-1/3 1/50-3/4 1/ /50-2 1/50-1 1/ /50-1 1/25-2 External Heat Sink (BC143) Required No No 1 2 Not Required Not Required Not Required Speed Range ( May Be 20: 1 Constant Torque) 50:1 50:1 50:1 50:1 50:1 50:1 Adjustable Acceleration Time Yes Yes Yes Yes Yes Yes Adjustable Deceleration Time Yes Yes Yes Yes Yes Yes Minimum Speed Adjustable Yes Yes Yes Yes Yes Yes Maximum Speed Adjustable Yes Yes Yes Yes Yes Yes Current Limit Adjustable Yes Yes Yes Yes Yes Yes Adjustable Current Limit and Trip Out Type No No No Timed or Non-Timed Timed or Non-Timed Timed or Non-Timed Control Of Speed or Torque Speed Speed Speed Speed or Torque Speed or Torque Speed or Torque IR Compensation Adjustable Yes Yes Yes Yes Yes Yes Tachometer Feedback Input No No No Yes Yes Yes Plug-In Horsepower Resistor Required Required Required N/A N/A N/A UL & cul ing, CE Yes Yes Yes Yes Yes Yes AC Line Fuse Included Included Included External External External DC Armature Fuse Included with Resistor Included with Resistor Included with Resistor Not Supplied with Control External Not Supplied with Control Options AC Line Switch Standard Standard Standard Opt - BC159 No Standard Forward/Brake/Reverse Switch Mechanical Electronic No No No No Opt-BC144 No Opt-BC156 Opt-BC153 No No Standard Opt-BC153 Run/Jog Switch No No No Opt-BC157 Opt-BC157 Standard Input Signal Internal Internal External Following Mode Capability Mount Mount Mount Opt-BC145 Current (1-5, 4-20, 20-50mA) No No Opt-BC145 Opt-BC145 Opt-BC145 Opt-BC145 Voltage (0-25,0-120, VDC) Standard Standard Standard (0-5,0-10 VDC) (0-5,0-10 VDC) (0-5,0-10 VDC) Electrical Connection To Control Standard Standard Standard Standard Standard Standard Barrier Terminal Block Current Sensing Relay/Overload No No Opt - BC146 Standard Standard Standard Protector Electronic Speed Potentiometer No No Opt-BC151 Opt-BC151 Opt-BC151 Opt-BC151 AC Line Filter for CE Opt-BC24-LF Opt-BC24-LF Opt-BC24-LF Opt-BC24-LF Opt-BC24-LF Opt-BC24-LF HVAC Farm Duty Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz Inverter/Vector & Controls Servo DC 243

244 HVAC Farm Duty Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz Inverter/Vector & Controls Servo Chassis Mount DC Control Specifications Features DC & Controls BC141 BC142 BC142-6 BC155 BC202 BC204 BC200 BC201 BC203 Enclosure Chassis Chassis Chassis Chassis Chassis Chassis Chassis Chassis Chassis Control Type K K K K Regenerative Regenerative Regenerative Regenerative Regenerative AC Line Input DC Armature Voltage Nominal Shunt Field Power Supply Voltage - DC 50/ /200 50/ /200 50/ /200 50/ /200 50/ /200 50/ / / /200 Rated Horsepower Range 1/ /50-3 1/ /2 5 1/4-3/4 1/8-1 1/4-1 1/4-1-1/2 5 1/50-3 1/2-1 1/2 1/4-2 1/2-2 1/2-3 External Heat Sink (BC143) Required 1 -Up 2 -Up 1/2 -Up 1 -Up Not Required Not Required 90V-1 180V-2 Not Required Not Required Not Required Speed Range ( may be 20:1Constant Torque) 50:1 50:1 50:1 50:1 50:1 50:1 50:1 50:1 50:1 Adjustable Acceleration Yes Yes Yes Yes Yes Fwd & Rev Yes Fwd & Rev Yes Fwd & Rev Yes Fwd & Rev Yes Fwd & Rev Adjustable Deceleration Yes Yes Yes Yes Regen Regen Regen Regen Regen Min.. Speed Adjustable Yes Yes Yes Yes No No No No No Max. Speed Adjustable Yes Yes Yes Yes Yes Yes Yes Yes Yes Adjustable Current Limit and Tripout Type Control of Speed or Torque Non Timed Non Timed Non Timed Non Timed Speed Speed Speed Speed Torque Timed Speed or Torque Non Timed Timed Timed Timed Speed or Speed or Speed or Speed Torque Torque Torque IR Compensation Adjustment Yes Yes Yes Yes Yes Yes Yes Yes Yes Tachometer Feedback Input Yes Yes Yes Yes Yes Yes Yes Yes Yes Plug-in Horsepower Resistor Required Required Required N/A N/A N/A N/A N/A N/A UL & cul ing, CE Yes Yes Yes Yes Yes Yes Yes Yes Yes AC Line Fuse Included Included Included External External External Included Included External DC Armature Fuse Options Input Signal Included with Resistor Included with Resistor Included with Resistor Included with Resistor Included with Resistor External Included with Resistor Included with Resistor Following Mode Capability Current (1-5,4-20,20-50 ma) Opt-BC145 Opt-BC145 Opt-BC145 Opt-BC145 No No Std No No No Voltage (0-25, 0-120, VDC) Opt-BC145 Opt-BC145 Opt-BC145 Std 0-10 VDC Std 0-±10 VDC Opt BC215 Std 0-±10 VDC Std 0-±10 VDC Std 0-±10VDC 0-25, 0-120, VDC) No No No No Opt-BC212 with BC214 Opt-BC212 Opt-BC212 Opt-BC212 Electrical Connection To Control Push-On Quick Connects Barrier Terminal Block Standard Opt-BC147 Standard Opt-BC147 Standard Opt-BC147 No Standard No Standard Standard N/A No Standard No Standard No Standard Current Sensing Relay/ Overload Protector Opt-BC146 Opt-BC146 Opt-BC146 Opt-BC146 Standard N/A Standard Standard Standard Regenerative Accel / Decel Board No No No No Opt BC211 with BC214 No Opt BC211 Opt BC211 Opt BC211 Electronic Speed Potentiometer Opt BC151 Opt BC151 Opt BC151 Opt BC151 Opt BC151 Opt BC151 Opt BC151 Opt BC151 Opt BC151 AC Line Filter for CE Opt-BC24-LF Opt-BC24-LF Opt-BC24-LF Opt-BC24-LF Opt-BC24-LF Opt-BC24-LF Opt-BC24-LF Opt-BC24-LF Opt-BC24-LF External DC 244

245 Series 29 One-way Digital DC SCR Control DC & Controls VAC 3 Phase 50/60 Hz. Applications: Constant torque applications such as plastic extruders and conveyors. HVAC Features: Protected chassis enclosure, selectable feedback with option boards, auto-tune, compact size. Application programs for electronic speed pot. Farm Duty Design Specifications Operator Keypad 3 phase input, full wave, single Digital Speed Control quadrant SCR armature control Forward / Reverse Command Peak overload capacity of 150% for RUN and JOG 30 seconds, 200% for 10 seconds, 250% for 3 seconds 5 assignable analog inputs 2 assignable analog outputs 5 assignable logic inputs 3 assignable logic outputs Local/Remote Key Stop Command Parameter Setting and Display 32 Character alpha-numeric display Remote mount to 10 feet from control Digital display for fault conditions LEDs for control status Environmental and Operating Conditions Input voltage: Same control works on 230 or 460 VAC input Service factor: 1.0 Duty: Continuous Size 1 and 2 controls have internal logic voltage supply-larger sizes require 115 VAC, 1 phase. Size 1 and 2 controls have built-in AC contactor and fuses Feedback Standard feedback type: Armature feedback (open loop) Optional feedback type with expansion board: DC or AC tachometer, Encoder or pulse generator Setup Windows -based setup control may be configured using Workbench-D software and cable kit CBLD030SW. Output Output Voltage DC; times VAC input Ratings Current Limit Adjustable 150% of rated current for 30 seconds, 200% for 10 seconds, 250% for 3 seconds Input Voltage VAC ± 10% Ratings Frequency 50 or 60 Hz ± 5% Phase Three phase Control Logic Supply Internally connected with voltage jumpers on sizes 1 and 2. Externally connected for 115 VAC on sizes 3 and larger Control Impedance 5% Maximum Spec. Control Method type C full wave uni-directional DC control Speed Setting ±10 VDC, 0-10 VDC, 4-20 ma. Digital via keypad. Optional by expansion board: RS485 serial, ProfibusDP or DeviceNet Accel / Decel seconds Min. Speed 0 100% rated speed Max Speed 0 200% rated speed Matching Automatic tuning to motor with manual override Field Type wave fixed voltage or current regulated Power Voltage DC; 0 to 90% of line input voltage Supply Current 4 amps on size 1, 10 amps on size 2 and 3, 30 amps on size 4 and 5 Field Economy Level Off or 50% Standard Feedback Type Armature feedback Feedback Optional Feedback Type Optional with expansion boards: DC or AC tachometer (200 volt max without dropping resistor), Incremental encoder or pulse generator (5 VDC or 12 VDC) Protective Functions Control Trip Missing control power; Over-current; Armature over-voltage; over-speed; Over temperature (motor and control); Phase Functions loss; overload and over-current; Field loss; Encoder or tachometer loss Fusing Standard input line, armature, field and control logic (Size 1 and 2 only); high energy MOVs External Output LED indicator for trip conditions, 3 assignable logic outputs 30 VDC max, 2 assignable 3 analog outputs ±10 VDC (2 assignable) LCD Running, Output current, Voltage (selectable) Display Setting Parameter values for setup and review Trip Separate message for each trip, last trip retained in memory Ambient Conditions Operating Temperature 0-45 C for size 1 and 2, 0-40 C for size 3, 4 and 5. Output current values should be de-rated at 1% per degree Centigrade above rated temperature up to a maximum of 55 C Storage Temperature -25 C to +55 C, shipping temperature -25 C to +70 C Altitude Up to 1640 ft (500m) above sea level without derating Cooling Forced air included on size 4 and 5 (separate 115/230 VAC 1ph power required) Approvals UL / CUL UL listed to US and Canadian safety standard UL508C (up to 675 amps larger ratings pending) CE Marked to EN50178 (Safety, Low Voltage Directive); EN (1992) (EMC emissions, industrial environment with external filter fitted); EN (1995) (EMC immunity, industrial environment) NOTE: Windows is a registered trademark of the Microsoft corporation. Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz Inverter/Vector & Controls Servo DC 245

246 HVAC Farm Duty Definite Purpose Brake 200 & 575 Volt Series 29 One-way Digital DC SCR Control continued Chassis Mount, Internal Logic Voltage Supply and AC Line Contactor Ap 230V Ap 460V Input Voltage Armature Output Current Amps Cont Amps Peak (G) Chassis Mount, Requires 115 Volt External Logic Voltage Supply and AC Line Contactor NOTE: (G) Peak amps of 150% for 30 seconds, 200% for 10 seconds and 250% for 3 seconds. DC & Controls OPTIONS: See page 248 for optional Expansion boards and other accessories-dc/ac Tachometer feedback, Encoder/pulse generator feedback, RS-485, Profibus DP, DeviceNet. Remote mounting kit for keypad. Chassis Size Ap x Wgt / BC29D7A35-CO Z / BC29D7A70-CO Z / BC29D7A110-CO Z / BC29D7A165-CO Z Ap 230V Ap 460V Input Voltage Armature Output Current Amps Cont Amps Peak (G) Chassis Size Ap x Wgt / BC29D7A243-CO Z / BC29D7A380-CO Z / BC29D7A500-CO Z IEC Dimensions in/(mm) 50 Hertz Inverter/Vector & Controls Outside Mounting Ap x Size Height Width Depth Height Width /(375) 7.9/(200) 8.7/(220) 14.2/(360) 5.5/(140) /(434) 7.9/(200) 11.5/(292) 16.5/(418) 5.5/(140) 23 3 (180A) 19.1/(485) 9.8/(250) 7.1/(234) 15.7/(400) 7.9/(200) 44 3 (270A) 19.7/(485) 11.8/(300) 8.3/(211) 26.8/(680) 5.9/(150) 44 4 (380A) 27.6/(700) 10/(253) 14.2/(258) 26.8/(80) 5.9/(150) 71 4 (500A) 27.6/(700) 10/(253) 14.2/(358) 26.8/(80) 5.9/(150) 71 4 (725A) 27.6/(700) 10/(253) 14.2/(358) 26.8/(680) 5.9/(150) 97 4 (830A) 27.6/(700) 10/(253) 14.2/(358) 26.8/(680) 5.9/(150) /(700) 20/(506) 14.2/(358) 26.8/(680) 15.9/(403) 200 Servo DC 246

247 Series 30 Line Regenerative Digital DC SCR Control DC & Controls VAC 3 Phase 50/60 Hz. Applications: Constant torque applications such as cranes and hoists, carriage drives, veneer lathes and conveyors. Features: Protected chassis enclosure, selectable feedback and bus communication with option boards, auto-tune, compact size. Application programs for Crane and Hoist and electronic speed pot. HVAC Farm Duty Design Specifications Operator Keypad Three phase input, full wave, four Digital Speed Control quadrant SCR armature control Forward / Reverse Command Peak overload capacity of 150% for RUN and JOG 30 seconds, 200% for 10 seconds 250% for 3 seconds 5 assignable analog inputs 2 assignable analog outputs 5 assignable logic inputs 3 assignable logic outputs Local/Remote Key Stop Command Parameter Setting and Display 32 Character alpha-numeric display Remote mount to 10 feet from control Digital display for fault conditions LEDs for control status Environmental and Operating Conditions Input voltage: Same control works on 230 or 460 VAC input Service factor: 1.0 Duty: Continuous Size 1 and 2 controls have internal logic voltage supply-larger sizes require 115 VAC, 1 phase. Size 1 and 2 controls have built-in AC contactor and fuses Feedback Standard feedback type: Armature feedback (open loop) Optional feedback type with expansion board: DC or AC tachometer, Encoder or pulse generator Setup Windows -based setup control may be configured using Workbench-D software and cable kit CBLD030SW. Output Output Voltage DC; times VAC input Ratings Current Limit Adjustable 150% of rated current for 30 seconds, 200% for 10 seconds, 250% for 3 seconds. Input Voltage VAC ± 10% Ratings Frequency 50 or 60 Hz ± 5% Phase Three phase Control Logic Supply Internally connected with voltage jumpers on sizes 1 and 2. Externally connected for 115 VAC on sizes 3 and larger Control Impedance 5% Maximum Spec. Control Method type C full wave bi-directional regenerative DC control Speed Setting ±10 VDC, 0-10 VDC, 4-20 ma digital via keypad. Optional by expansion board: RS485 serial, ProfibusDP or DeviceNet Accel / Decel seconds Min. Speed 0 100% rated speed Max Speed 0 200% rated speed Matching Automatic tuning to motor with manual override Field Type wave fixed voltage or current regulated full wave Power Voltage DC; 0 to 90% of line input voltage Supply Current 4 amps on size 1, 10 amps on size 2 and 3, 30 amps on size 4 and 5 Field Economy Level Off or 50% Standard Feedback Type Armature feedback Feedback Optional Feedback Type Optional with expansion boards: DC or AC tachometer (200volt max without dropping resistor), Incremental encoder or pulse generator (5 VDC or 12 VDC) Protective Functions Control Trip Missing control power; Over-current; Armature over-voltage; over-speed; Over temperature (motor and control); Phase Functions loss; overload and over-current; Field loss; Encoder or tachometer loss Fusing Standard input line, armature, field and control logic (Size 1 and 2 only); high energy MOVs External Output LED indicator for trip conditions, 3 assignable logic outputs 30 VDC max, 3 analog outputs ±10 VDC (2 assignable) LCD Running, Output current, Voltage (selectable) Display Setting Parameter values for setup and review Trip Separate message for each trip, last trip retained in memory Ambient Conditions Operating Temperature 0-45 C for size 1 and 2, 0-40 C for size 3, 4 and 5. Output current values should be de-rated at 1% per degree Centigrade above rated temperature up to a maximum of 55 C Storage Temperature -25 C to +55 C, shipping temperature -25 C to +70 C Altitude Up to 1640 ft (500m) above sea level without derating Cooling Forced air included on size 4 and 5 (separate 115/230 VAC 1ph power required) Approvals UL / CUL UL listed to US and Canadian safety standard UL508C (up to 675 amps larger ratings pending) CE Marked to EN50178 (Safety, Low Voltage Directive); EN (1992) (EMC emissions, industrial environment with external filter fitted); EN (1995) (EMC immunity, industrial environment) NOTE: Windows is a registered trademark of the Microsoft corporation. Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz Inverter/Vector & Controls Servo DC 247

248 HVAC Farm Duty Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz Inverter/Vector & Controls Servo DC DC & Controls Series 30 Line Regenerative Digital DC SCR Control continued Chassis Mount, Internal Logic Voltage Supply and AC Line Contactor Ap 230V Chassis Mount, Requires 115 Volt External Logic Voltage Supply and AC Line Contactor Ap 230V Ap 460V Ap 460V NOTE: (G) Peak amps of 150% for 30 seconds, 200% for 10 seconds and 250% for 3 seconds. Dimensions in/(mm) Input Voltage Armature Output Current Amps Cont Amps Peak (G) Accessories and Expansion Boards for Series 29 and 30 DC SCR Controls Chassis Size Ap x Wgt / BC30D7A243-CL Z / BC30D7A380-CL Z / BC30D7A500-CL Z Outside Mounting Ap x Size Height Width Depth Height Width /(375) 7.9/(200) 8.7/(220) 14.2/(360) 5.5/(140) /(434) 7.9/(200) 11.5/(292) 16.5/(418) 5.5/(140) 23 3 (180A) 19.1/(485) 9.8/(250) 7.1/(234) 15.7/(400) 7.9/(200) 44 3 (270A) 19.7/(485) 11.8/(300) 8.3/(211) 26.8/(680) 5.9/(150) 44 4 (380A) 27.6/(700) 10/(253) 14.2/(258) 26.8/(80) 5.9/(150) 71 4 (500A) 27.6/(700) 10/(253) 14.2/(358) 26.8/(80) 5.9/(150) 71 4 (725A) 27.6/(700) 10/(253) 14.2/(358) 26.8/(680) 5.9/(150) 97 4 (830A) 27.6/(700) 10/(253) 14.2/(358) 26.8/(680) 5.9/(150) /(700) 20/(506) 14.2/(358) 26.8/(680) 15.9/(403) 200 EXBD01A01 EXBD02A01 EXBD02A02 EXBD03A01 EXBD04A01 EXBD05A01 CBLD030KP CBLD030P3 CBLD030SW ACBD01A01 ACBD02A01 ACBD03A01 ACBD04A01 Input Voltage Armature Output Current Amps Cont Amps Peak (G) Description DC/AC tachometer expansion board Encoder input (5V) expansion board Encoder input (12V) expansion board RS-485/Modbus serial communication expansion board Profibus DP communication expansion board DeviceNet communication expansion board Keypad remote mounting 3 meter lead Serial P3 port to DB9 cable - 3 meters Serial P3 to DB9 cable with Workbench-D software Spare keypad Remote mounting bezel with 3 meter lead Remote mounting bezel Remote mounting panel seal Z8 Z8 Z8 Z8 Z8 Z8 Z8 Z8 Z8 Z8 Z8 Z8 Z8 Chassis Size Ap x Ap x Wgt / BC30D7A35-CL Z / BC30D7A70-CL Z / BC30D7A110-CL Z / BC30D7A165-CL Z

249 Series 19H Digital DC Controls DC & Controls 5 thru VAC - 50/60 Hz 5 thru VAC - 50/60 Hz HVAC Applications: Constant torque applications. New installations, replacements and original equipment manufacturers (OEM). Features: Chassis mounting, built-in armature or encoder feedback, high peak currents. Farm Duty Design Specifications Three phase, full wave SCR armature control High peak overload, % (depending on rating) Selectable operating modes: Keypad; Standard Run,15 Speed, Bipolar speed/ torque; Serial; Process follower mode. Analog meter outputs Buffered encoder output 9 isolated inputs Chassis mounting Output Ratings Input Ratings Control Spec. Field Power Supply Feedback Protective Functions Voltage Operator Keypad Digital Speed Control Forward/Reverse Command RUN and JOG Local/Remote Key Stop Command (coast or external DB to stop) 32 Character alpha-numeric display Remote mount to 100 feet from control 4X enclosure on keypad DC times VAC input Environmental and Operating Conditions Input Frequency - 50 or 60 Hz ± 5% Service factor Duty - continuous Humidity - 90% max RH non-condensing Altitude feet max without derate Protective Features Control Input over and under voltage Encoder, tach or resolver loss Torque proving Selectable manual or automatic restart at power loss Digital display for fault conditions Feedback 1024 PPR standard (with quadrature) Power output: +5VDC, 300 ma max Max frequency: 1 MHz Optional feedback: tachometer or resolver through expansion board Frequency 50 or 60 Hz ± 5% Voltage VAC ± 10%; VAC ± 10% Phase Three phase Impedance 5% maximum Control Method wave-uni-directional DC control, type C Speed Setting 0-5VDC, 0-10VDC, 4-20 ma, digital via keypad, optional RS232/422/485 Accel/Decel seconds (decel-coast or controlled by external DB resistors) - no S-curve decel Minimum Speed 0-maximum speed Maximum Speed Matching Automatic tuning to motor with manual override Type Voltage limited, current regulated full wave single phase Voltage 0 to 10-85% of AC line Input in DC volts Current Amps maximum-standard, amps maximum-optional Field Economy Level OFF, % Field Forcing Level % (hoist modes only) Feedback Type Armature or incremental encoder coupled to motor shaft Pulses/Rev selectable, 1024 standard Voltage Output 2 channel in quadrature, 5VDC differential Marker Pulse Required for position orientation Power Input 5VDC, 300 ma maximum Maximum Frequency 1 MHz Optional Feedback Tachometer or resolver via expansion board Control Trip Missing control power, over current armature over voltage, motor overspeed over temperature (motor & control), field loss, encoder tach or resolver loss, phase loss, motor overload and overcurrent Fusing Standard input line, armature and field power supply fuses External Output LED indicator for trip conditions, 4 assignable logic outputs - 30VDC Max, 2 assignable analog outputs 0-5VDC LCD Display Running, output current, voltage (selectable) Setting Parameter values for setup and review Trip Separate message for each trip, last 31 trips retained in memory Ambient Temperature 0-40 C for UL listing Conditions Cooling Forced air included when required NOTE: Use of DC tach for feedback requires DC Tachometer Interface Board, catalog number EXB006A01. Other expansion boards are available, see pages Definite Purpose Brake 200 & 575 Volt IEC 50 Hertz Inverter/Vector & Controls Servo DC 249

250 HVAC Farm Duty Definite Purpose Brake 200 & 575 Volt Series 19H Digital DC Controls continued OPTIONS: See pages for optional Expansion Boards including Tachometer Feedback, RS-232, RS-422, RS-485, Resolver, Interface, etc. 40 Amp field power supply. FPS40BC1920 DC & Controls Armature Output Current Chassis Input Volt Amps Cont Amps Peak Size 230 Volt Input VDC Output BC19H205-CO 4721 E1 A BC19H210-CO 4721 E1 A BC19H215-CO 5073 E1 A BC19H220-CO 5484 E1 B BC19H225-CO 5777 E1 B BC19H240-CO 7408 E1 C BC19H250-CO 7966 E1 C BC19H260-CO 8801 E1 C BC19H275-CO 9544 E1 C 460 Volt Input VDC Output BC19H410-CO 4808 E1 A BC19H420-CO 4808 E1 A BC19H430-CO 5191 E1 A BC19H440-CO 5613 E1 B BC19H450-CO 5907 E1 B BC19H475-CO 7789 E1 C BC19H4100-CO 8318 E1 C BC19H4125-CO 9151 E1 C BC19H4150-CO 9907 E1 C BC19H4200-CO E1 D BC19H4300-CO E1 D IEC 50 Hertz Inverter/Vector & Controls Dimensions in/(mm) Outside Mounting Ap x Size Height Width Depth Height Width A ALL 20.60/(523.2) 11.00/(279.4) 9.87/(250.7) 18.00/(457.2) 10.25/(260.4) 39 B 230V ALL 25.70/(652.8) 11.00/(279.4) 9.84/(249.9) 23.87/(606.3) 10.25/(260.4) 67 B 460V ALL 26.75/(679.5) 11.00/(279.4) 9.84/(249.9) 24.94/(633.5) 10.25/(260.4) 69 C 230V /(673.1) 11.75/(298.5) 10.63/(270.0) 23.90/(607.0) 10.25/(260.4) 80 C 460V /(692.2) 11.75/(298.5) 10.63/(270.0) 24.65/(626.1) 10.25/(260.4) 84 C 230V /(838.2) 11.75/(298.5) 10.63/(270.0) 23.90/(607.6) 10.25/(260.4) 94 C 460V /(857.3) 11.75/(298.5) 10.63/(270.0) 24.65/(626.1) 10.25/(260.4) 97 D ALL 43.80/(1112.5) 16.87/(428.5) 12.43/(315.7) 39.25/(997.0) 13.75/(349.3) 272 Servo DC 250

251 Series 20H Line Regenerative Digital DC Controls DC & Controls 5 thru VAC - 50/60 Hz 5 thru VAC - 50/60 Hz Applications: Constant torque applications. New installations, replacements and original equipment manufacturers (OEM). Features: Chassis mounting, built-in armature or encoder feedback. High peak current. HVAC Farm Duty Design Specifications Three phase, full wave, four quadrant SCR armature control. Peak overload capacity of % (depending on rating) Selectable operating modes: Keypad, Standard Run, 15 Speed, Bipolar speed/torque, Serial, Bipolar Hoist, 7 Speed Hoist, process follower shaft orient to encoder marker or external switch closure (encoder feedback) 15 preset speeds (7 in Hoist Mode.) Operator Keypad Digital Speed Control Forward/Reverse Command RUN and JOG Local/Remote Key Stop Command 32 Character alpha-numeric display Remote mount to 100 feet from control 4X enclosure on keypad Environmental and Operating Conditions Input frequency - 50 or 60Hz ±5% Service factor Duty - continuous Humidity - 90% max RH non-condensing Altitude feet max without derate Protective Features Torque proving Selectable manual or automatic restart at power loss Digital display for fault conditions Feedback Power output: +5VDC, 300 ma max Positioning: Buffered encoder pulse train output for position loop control Optional feedback: tachometer or resolver through expansion board Definite Purpose Brake Output Ratings Voltage DC times VAC input Input Ratings Control Spec. Field Power Supply Feedback Protective Functions Frequency 50 or 60 Hz ± 5% Voltage VAC ± 10%; VAC ± 10% Phase Three phase Impedance 5% maximum Control Method wave-bi-directional regenerative DC control, type C Speed Setting ±5VDC, 0-5VDC, ±10VDC, 0-10VDC, 4-20 ma, digital via keypad, optional RS232/422/485 Accel/Decel seconds or s-curve Minimum Speed 0-maximum speed Maximum Speed Matching Automatic tuning to motor with manual override Type Voltage limited, current regulated full wave single phase Voltage 0 to 10-85% of AC line Input in DC volts Current Amps maximum-standard, amps maximum-optional Field Economy Level OFF, % Field Forcing Level % (hoist modes only) Feedback Type Armature or incremental encoder coupled to motor shaft Pulses/Rev selectable, 1024 standard Voltage Output 2 channel in quadrature, 5VDC differential Marker Pulse Required for position orientation Power Input 5VDC, 300 ma maximum Maximum Frequency 1 MHz Positioning Optional buffered encoder pulse train output for position loop controller Optional Feedback Tachometer or resolver via expansion board Control Trip Missing control power, over current armature over voltage, motor overspeed over temperature (motor & control), field loss, encoder tach or resolver loss, phase loss, motor overload and overcurrent Fusing Standard input line, armature and field power supply fuses External Output LED indicator for trip conditions, 4 assignable logic outputs - 30VDC Max, 2 assignable analog outputs 0-5VDC LCD Display Running, output current, voltage (selectable) Setting Parameter values for setup and review Trip Separate message for each trip, last 31 trips retained in memory Ambient Temperature 0-40 C for UL listing Conditions Cooling Forced air included when required NOTE: Use of DC tach for feedback requires DC Tachometer Interface Board, catalog number EXB006A01. Other expansion boards are available, see pages & 575 Volt IEC 50 Hertz Inverter/Vector & Controls Servo DC 251

252 HVAC Farm Duty Definite Purpose Brake 200 & 575 Volt Series 20H Line Regenerative Digital DC Controls DC & Controls Armature Output Current Chassis Input Volt Amps Cont Amps Peak Size 230 Volt Input VDC Output BC20H205-CL 5501 E1 A BC20H210-CL 5501 E1 A BC20H215-CL 5501 E1 A BC20H220-CL 5766 E1 B BC20H225-CL 6493 E1 B BC20H240-CL 8422 E1 C BC20H250-CL 9113 E1 C BC20H260-CL 9636 E1 C BC20H275-CL E1 C 460 Volt Input VDC Output 5, 7.5, BC20H410-CL 5789 E1 A 15, BC20H420-CL 5789 E1 A 25, BC20H430-CL 5976 E1 A BC20H440-CL 6240 E1 B BC20H450-CL 6920 E1 B 60, BC20H475-CL 9575 E1 C BC20H4100-CL E1 C BC20H4125-CL E1 C BC20H4150-CL E1 C BC20H4200-CL E1 D BC20H4250-CL E1 D BC20H4300-CL E1 D OPTIONS: See pages for optional expansion Boards including Tachometer Feedback, RS-232, RS-422, RS-485, Resolver,Interface, etc. 40 Amp field power supply. FPS40BC1920 NOTE: Voltage at 60 Hz: E1= 230/460 usable at 208 volts. IEC Dimensions in/(mm) 50 Hertz Inverter/Vector & Controls Outside Mounting Ap x Size Height Width Depth Height Width A ALL 20.60/(523.2) 11.00/(279.4) 9.87/(250.7) 18.00/(457.2) 10.25/(260.4) 39 B 230V ALL 25.70/(652.8) 11.00/(279.4) 9.84/(249.9) 23.87/(606.3) 10.25/(260.4) 67 B 460V ALL 26.75/(679.5) 11.00/(279.4) 9.84/(249.9) 24.94/(633.5) 10.25/(260.4) 69 C 230V /(673.1) 11.75/(298.5) 10.63/(270.0) 23.90/(607.0) 10.25/(260.4) 80 C 460V /(692.2) 11.75/(298.5) 10.63/(270.0) 24.65/(626.1) 10.25/(260.4) 84 C 230V /(838.2) 11.75/(298.5) 10.63/(270.0) 23.90/(607.6) 10.25/(260.4) 94 C 460V /(857.3) 11.75/(298.5) 10.63/(270.0) 24.65/(626.1) 10.25/(260.4) 97 D ALL 43.80/(1112.5) 16.87/(428.5) 12.43/(315.7) 39.25/(997.0) 13.75/(349.3) 272 Servo DC 252

253 Digital Speed Potentiometer with Display DC & Controls Baldor s microprocessor-based digital speed potentiometer with LED display of set speed may be used to replace the conventional 3-wire analog speed pot for most AC and DC drives. Desired set speed may be entered into the large 1/2 LED display by pressing the up and down pushbuttons: one digit at a time or in a fast sweep. Display shows 0.1% increments of full motor speed (0-100%). HVAC Farm Duty Specifications Temperature -10 C to +45 C AC input voltage VAC Input frequency 50/60 Hz Supply voltage applied across output 5 VDC to 15 VDC Speed regulation Same as driven unit Input impedance to DSP4 will drive 500 ohm to 100 K ohm Output Isolated 3-wire pseudo-pot (normal or inverted output) Display settings 0-100% of set speed range in 0.1% increments (resolution of 1000) Non-volatile memory Retains last set point upon loss of AC power (user selectable via dip switch settings) Input Description Voltage DSP4-6 Digital Speed Potentiometer with Display 456 E /240 VAC 50/60 hz Definite Purpose Brake 200 & 575 Volt Field Programmable Digital Tachometer for Rate and Time with Display Baldor offers an economical micro-processor-based digital tachometer capable of measuring motor speeds as low as 1 rpm that is field programmable for desired user specified units:, FPM and GPM. Process time or other engineering units requires an input signal unit with 1 to 30,000 PPR such as the HPU and RK60 devices. For use with digital tachometers. IEC 50 Hertz Specifications Temperature AC input voltage Input frequency Input pulse rate Resolution Accuracy Isolated high/low alarm output Transducer signal input -10 C to +45 C VAC 50/60 Hz 1 to 30,000 input pulses per minute from 0.01 ±0.04% display update every pulse or 0.5 seconds, whichever is longer 5 amp 240 VAC max. 0-5 to 0-24 VDC square wave (hall-effect, photoelectric, magnetic or any TTL NPN open collector device.) Inverter/Vector & Controls Servo Input Description Voltage DTM Digital Tachometer for Rate & Time with Display 499 E /240 VAC 50/60 hz DC 253

254 HVAC Farm Duty Hall Effect Pickup HPU10 DC & Controls Provides square wave pulse feedback. HPU mounts to a stub shaft opposite the pulley end of the motor and provides 10 pulses per revolution. May be installed through Baldor s Mod-Express Features: HPU10 Series pick-up mounts directly on shaft being monitored using a single screw (motor shaft requires modification and/or an adapter). Use with BC450/BC440 DC controls and DTM8000 digital tachometer. Definite Purpose Brake 200 & 575 Volt Specifications Temperature Supply Voltage Maximum Speed Output Cable Output Signal Bearings Enclosure -10 C to +45 C +4.5 to +24 VDC foot rubber-jacketed, 3 wire 18 AWG conductors Red Wire: Black Wire: White Wire: Hall Effect Pickup RK60 +VDC supply input Common Signal 10 pulses per revolution NPN output signal with built-in pull-up resistor. Square wave output, signal voltage equals supply voltage. +5 VDC to +24 VDC supply voltage. Current sink: 5 ma maximum Stainless steel ball bearing Compact housing molded of Santoprene plastic rubber Provides square wave pulse feedback. The RK models are ring kits that mount to the 56C and 145TC face of the motor. May be installed through Baldor s Mod-Express IEC 50 Hertz Inverter/Vector & Controls Servo Specifications Temperature Supply Voltage Output Connection Output Signal Sensing Disk Mounting -40 C to +125 C +4.5 to +24 VDC 3 wires Red Wire: Black Wire: Blue Wire: Features: RK60 Series hall effect pick-up consists of a motor mounted C-face ring, sensor, mounting bolts, and magnet disc. Use with BC450/ BC440 DC controls and DTM8000 digital tachometer. +VDC supply input Common Signal 60 pulses per revolution NPN output signal (may require external pull-up resistor). Square wave output, signal voltage equals supply voltage. +5 VDC to +24 VDC supply voltage. Current sink: 20 ma Molded magnet sensing disc, impervious to dust, dirt, and oil C-face mounting ring has double C-face and is thick. (Please note that usable shaft length will be reduced by 0.750". Check application for suitability). TK3300-HPU Mounting Kit for TENV/33P DC TK3400-HPU Mounting Kit for TEFC/34P DC DC 254 Description HPU10 10 PPR Hall-Effect Pickup 165 E9 2 RK PPR Hall-Effect Pickup with 56C Ring Kit 545 E9 2 RK PPR Hall-Effect Pickup with TC Ring Kit 545 E9 2 TK3300-HPU HPU10 Mounting Kit for TENV/33P DC (does not include pickup) 65 A8 1 TK3400-HPU HPU10 Mounting Kit for TEFC/34P DC (does not include pickup) 75 A8 1

255 DC & Controls Digital DC Controls 1/20 thru VAC Single Phase 50/60 Hz 1/8 thru VAC Single Phase 50/60 Hz HVAC Applications: General purpose industrial use with permanent magnet motors. Features: Compact programmable DC speed control with digital closed loop feedback and LED display. Front-panel programming allows customizing the control function and can display the set speed in, FPM, GPM, process time or any other engineering units. Programmable parameters include minimum and maximum speed, decimal points, operating mode (leader or follower), and Run/Jog functions. Industry standard cutout dimensions of 1/8 DIN and 1/4 DIN provide easy panel installation and 4X faceplate with supplied gasket. Use with hall effect pickup shown on page 254. Farm Duty Definite Purpose Specifications Temperature AC input voltage Input frequency Overload capacity Feedback Input On-board power supply Pulse input capacity -10 Deg C to +45 Deg C Universal power supply rated at 85 to 265 VAC 50/60 Hz 200% for 1 minute 0-24 Volt Square Wave Digital Tachometer 5 VDC, 50mA (for external feedback sensor) 50,000 PPM (500,000 with divider function on) Brake 200 & 575 Volt Range 1/20-1/2 1/8-1 BC440-6 Description Digital Closed Loop DC Speed Control, 1/8 DIN Panel Mount Input Voltage 704 E VAC 50/60 Hz 230 VAC 50/60 Hz IEC 1/8-1 1/4-2 BC450-6 Digital Closed Loop DC Speed Control, 1/4 DIN Panel Mount 959 E VAC 50/60 Hz 230 VAC 50/60 Hz DC Servo Inverter/Vector & Controls 50 Hertz 255

256 Soft Start & Dynamic Brakes Digital Soft Start Controls Soft Starters & Dynamic Brakes 9 thru 900 Amps V 50/60 Hz. 9 thru 900 Amps V 50/60 Hz. Gearmotors and Gear Products Accessories Applications: Controlled ramp start and stop, minimize spillage in material handling, reduced water hammer in pumping, reduced wear on mechanical gears, eliminate high inrush current, and energy optimizing of under loaded motors. Typical applications include: pumps, conveyors, fans, reciprocating compressors and screw and rotary compressors Features: Six SCR three phase voltage control with programmable starting ramp and current limit. Application software senses changing load conditions and adapts to increase performance. Power factor optimization eliminates motor over-fluxing and allows under-loaded or over-sized motors to operate more efficiently. 1 enclosure. Grinders Generators Mod Express Baldor Education Workshops Index Baldor District Offices Design Specifications MOV protection Current feedback Microprocessor Control Power factor sensing Energy optimization One programmable input Two programmable form C outputs Output Voltage V, V Current 9-900A Horsepower Short Circuit Altitude Derate Voltage and application rated, Amperes symmetrical 1% per 330 feet above 3300 feet Temperature Derate 2% per one C above 40 C up to 60 C Overload Standard Duty 300% full load amps at 35 seconds, 400% full load amps at 6 seconds Input Ratings Control Spec SCR Spec Ambient Conditions Medium Duty Heavy Duty Voltage V, V Frequency Phase Control Method Start Time Stop Time 300% full load amps at 60 seconds, 400% full load amps at 12 seconds 300% full load amps at 80 seconds, 400% full load amps at 35 seconds 50/60 Hz Three Phase Microprocessor controlled full wave, three phase, six thyristor firing Programmable seconds Programmable seconds Voltage Pedestal Programmable: Start 10-60%, Kick 60-90%, Stop 10-60% Current Limit Power Factor Control Power Custom Product Capabilities 12, 4 or 3R enclosures with bypass contactor Flange mounted input disconnect Input circuit breaker or fuses Input contactor 3 wire start/stop pushbuttons 2 wire Hand-Off-Auto switch Indicating lights Large units up to 1800 amps 800% of rated current Continuously monitored to eliminate motor over-flux for power optimizing VAC, 50/60 Hz Peak Inverse Voltage 460VAC controllers 1400V 575VAC controllers 1600V Heat Loss 3.3 Watts per 1 Ampere running current Temperature Enclosed 0-40 C Cooling Convection / Forced Air included when required Altitude 3300 feet above sea level Environmental and Operating Conditions Input voltage 3 phase V Control voltage 120VAC Input frequency 50/60 Hz Humidity 90% RH condensing 3000 feet altitude 40 C ambient temperature Protective Features Current limit Shorted SCR detection SCR overload Shear pin-over-current detection Low current/under-load detection Input phase loss on start up Heat sink over-temperature 256

257 Digital Soft Start Controls - Typical Applications Standard Duty Agitator Axial Blower Axial Fan Band Saw Centrifugal Pump Chiller Escalator Low Inertia Fan Propeller Fan Small Pump Medium Duty Circular Saw Conveyor, Screw Feeder Drilling Press Elevator Flywheel Press Grinder Hammer Press High Inertia Fan Large Pump Mill Mixer Pelletizer / Pulper Positive Displacement Pump Reciprocating Compressor Vibrating Screen Soft Starters & Dynamic Brakes Heavy Duty Centrifugal Blower Centrifugal Fan Chipper Disintegrator ed Centrifuge ed Mixer ed Screw Compressor ed Reciprocating Compressor Pulverizer Rock Crusher Separator Standard Duty (1) Medium Duty (2) Heavy Duty (3) Cont. Output 208V(4) 230V 460V 208V(4) 230V 460V 208V(4) 230V 460V Amps Size Application 10 Starts per hour Maximum MD7-009-CB 1438 E MD7-016-CB 1495 E MD7-023-CB 1645 E MD7-030-CB 1787 E MD7-044-CB 2037 E MD7-059-CB 2282 E MD7-072-CB 2580 E MD7-085-CB 2728 E MD7-105-CB 3288 E MD7-146-CB 3886 E MD7-174-CB 5151 E MD7-202-CB 5716 E MD7-242-CB 6144 E7 2 Application 3 Starts per hour Maximum MD7-300-CB 6849 E MD7-370-CB 7416 E MD7-500-CB E MD7-600-CB E MD7-750-CB E MD7-900-CB E7 3 Soft Starters & Dynamic Brakes Gearmotors and Gear Products Accessories Grinders Generators Mod Express Standard Duty (1) Medium Duty (2) Heavy Duty (3) Cont. Output 575V 575V 575V Amps Size Application 10 Starts per hour Maximum MD8-009-CB 1654 E MD8-016-CB 1719 E MD8-023-CB 1891 E MD8-030-CB 2054 E MD8-044-CB 2341 E MD8-059-CB 2624 E MD8-072-CB 2966 E MD8-085-CB 3137 E MD8-105-CB 3781 E MD8-146-CB 4469 E MD8-174-CB 5923 E MD8-202-CB 6574 E MD8-242-CB 7065 E7 2 Application 3 Starts per hour Maximum MD8-300-CB 7765 E MD8-370-CB 8529 E MD8-500-CB E MD8-600-CB E MD8-750-CB E MD8-900-CB E7 3 NOTE: (1) 300% 35 Sec., 400% 6 Sec. (2) 300% 60 Sec., 400% 12 Sec. (3) 300% 80 Sec., 400% 35 Sec. (4) 208V applications are UL listed only to 196V. Baldor Education Workshops Index Baldor District Offices 257

258 Soft Start & Dynamic Brakes Digital Soft Start Controls - Dimensions Dimensions in/(mm) Soft Starters & Dynamic Brakes Gearmotors and Gear Products Size Outside Mounting Ap x Height Width Depth Height Width /(420) 8.7/(222) 7.7/(195) 15.7/(400) 5.9/(150) 16.1/(7.3) or 18.3/(8.3) > 44 amp /(520) 13.4/(340) 10.4/(265) 19.7/(500) 9.8/(250) 34.5/(15.7) or 48.4/(22) > 200 amp 3 24/(610) 26.6/(675) 15.7/(400) 22.7/(575) 19.7/(500) 143/(65) or 158.4/(72) > 600 amp Accessories Digital Soft Start Controls - Accessories Grinders Generators Mod Express Baldor Education Workshops Index Baldor District Offices External MOV Protects from line-to-line voltage spikes Recommended for all low line impedance applications Remote Keypad with Cable 32 Character English alphanumeric display 4X indoor enclosure Backlit LCD Expansion Board Two programmable relay outputs with FORM C contact (normally open and normally closed) Two programmable analog outputs 10mA maximum) One programmable or 4-20mA analog input Cable Length CBLDS015KP 5 ft. 379 E8 Volts EB0389A00SP 532 E8 MOV505L E7 MOV620EL E7 258

259 Multipurpose Solid State Soft Starter Soft Starters & Dynamic Brakes 8 thru 420 Amps 208/230/460V 60 Hz. 8 thru 30 Amps 208/230/460/575V 60 Hz. Soft Starters & Dynamic Brakes Applications: Controlled ramp start and stop, minimize spillage in material handling applications and water hammer in pumping equipment. Current limit provides a current ceiling to limit peak demand on start and constant current starting of high inertial loads such as chippers, centrifuges and compressors. Typical applications include: small and large pumps, conveyors, low and high inertia fans, reciprocating compressors, screw and rotary compressors. Features: Six SCR power devices and several enclosure options.tachometer feedback may be used to provide consistent starting independent of load conditions on textile, material handling and pumping equipment. Gearmotors and Gear Products Accessories Design Specifications Current feedback Microprocessor Control Power factor sensing Energy optimization One programmable input Two programmable form C outputs Programmable current limit Environmental and Operating Conditions Input voltage 3 phase V Control voltage 120VAC Input frequency 50/60 Hz Humidity 90% RH condensing 3000 feet altitude 40 C ambient temperature Protective Features Current limit Shorted SCR detection SCR overload Shear pin-over-current detection Low current/under-load detection Input phase loss on start up Heat sink over-temperature Grinders Model # Control only Output Ratings Input Rating Control Spec. SCR Spec. Protective Functions Ambient Conditions 208/230/460 VAC 60 Hz. MA7-008-CA MA7-016-CA MA7-030-CA MB7-055-CP MB7-080-CP MB7-160-CP MB7-250-CP MB7-420-CP 208/230/460/575 VAC 60 Hz. MA8-008-CA MA8-016-CA MA8-030-CA 230 VAC Rating 460 VAC VAC Current Rating 8 Amp 16 Amp 30 Amp 55 Amp 80 Amp 160 Amp 240 Amp 420 Amp Overload Rating Continuous 115% of FLA; 400% for 30 seconds Derate Above 1000m (3300 Ft.) decrease amp rating 1% for each additional 100m (330 ft.) Above 45 (115 F) decrease amp rating 1.% for each additional C (0.84%/ F) Frequency 60 Hz. ±5% Voltage +10% to -15% (except for 575 VAC units max. VAC is 620) Phase Three Phase Control Method 6 SCRs connected in inverse parallel for full-wave control Start Time Adjustable 3-50 seconds (current limit starting is not timed) Stop Time Adjustable 5-50 seconds to extend stopping time Initial Torque Adjustable starting 0-75%: Stopping 0-100% Current Limit Adjustable % of full load amps Pulse Time Adjustable seconds Current Monitor Adjustable % of full load amps (causes a contact closure or control shut down when current level is reached after starting) Power Factor Adjustable for max. reduced motor voltage dependent on motor load Control Power Self-powered External Transformer Status Contacts 125 VAC at 0.5 Amp normally open Peak Inverse Voltage 460 VAC Starters 1200 VAC 575 VAC Starters 1600 VAC Heat Loss 3.3 watts per running amp Over Current Over current shut down at 450% of motor full load amps Shorted SCR Detection Shunt trip contact SCR Thermostat Trips on over temperature of heat sink on 55 amp sizes and above Voltage Transient Metal oxide varistor (MOV) Temperature Enclosed 0-45 C (32 to 113 F) open/panel 0 to 50 C (32 to 122 F) Cooling Convection Forced Air Generators Mod Express Baldor Education Workshops Index Baldor District Offices 259

260 Soft Start & Dynamic Brakes Gearmotors and Gear Products Accessories Grinders Generators Mod Express Baldor Education Workshops Index Baldor District Offices 260 Multipurpose Solid State Soft Starter Soft Starters & Dynamic Brakes Amp Max at VAC Size Combination Starter /230/460 Volts (can also be used for 1) MB7-055-GC E MB7-080-GC 5459 E MB7-160-GC E MB7-250-GC E MB7-420-GC E /230/460 Volts MB7-080-AB 6611 E MB7-160-AB 8717 E MB7-250-AB E MB7-250-AB E MB7-420-AB E7 Non-Combination Starter /230/460 Volts MB7-160-BB 7373 E MB7-250-BB 8203 E MB7-420-BB 9861 E7 Control Only Open/Panel - 208/230/460 Volts MA7-008-CA 1082 E MA7-016-CA 1138 E MA7-030-CA 1336 E MB7-055-CP 2532 E MB7-080-CP 3628 E MB7-160-CP 4722 E MB7-250-CP 6471 E MB7-420-CP 8127 E7 Open/Panel Volts MA8-008-CA 1129 E MA8-016-CA 1196 E MA8-030-CA 1382 E /230/460 Volts MB7-160-CB 5737 E MB7-250-CB 7519 E MB7-420-CB 9056 E7 NOTE: 1 Combination Starter includes control, overload relay and circuit breaker. Non-combination Starter includes control and overload relay. 2 Uses a shunt bypass contactor to short SCR after ramp up (not a full voltage bypass starter). Custom controls available. Single Phase Starter 7 thru 110 Amps 115/230V 50/60 Hz. Applications: Use with existing or new magnetic starter. This industrial solid state control will reduce initial starting torque and current of single phase motors allowing them to be started with minimum voltage drop. High starting torque problems such as belt slippage may be eliminated. Ideal for crop driers, augers, bucket elevators and fan or pump applications. Features: Two adjustable starting torque settings. Adjustable starting ramp time to 30 seconds. Amp Max at VAC Size Open/Panel - 115/230 Volts - 50/60 Hz. (Available in 1 and 12/3R enclosures) 7 1/4 3/4 S20CA 458 E7 12 1/2 2 S21CA 476 E S22CA 509 E S23CA 543 E S25CA 908 E7 NOTE: To size single phase starters use the motor FLA. There is a great variation in FLA between motor manufacturers in these sizes.

261 Definite Purpose Soft Start Control Soft Starters & Dynamic Brakes 8 thru 135 Amps 208/230/460V 60 Hz. 8 thru 30 Amps 220/380/415V 50 Hz. 8 thru 30 Amps 575V 60 Hz. Applications: Use with magnetic starter. Excellent for retrofit on cranes, conveyors or fans. Can be used on single speed, multispeed and reversing, soft starting windmilling fans and soft plug reversing. Soft Starters & Dynamic Brakes Gearmotors and Gear Products Features: Two adjustable starting torque settings for reversing or two speed applications. Adjustable ramp time from 2-30 seconds. Amp Max at VAC Size Open/Panel - (Available in 1 and 12/3R enclosures) 208 Volt 230 Volt 460 Volt D70CA 767 E D71CA 823 E D72CA 926 E D73CP 1901 E D74CP 2480 E D75CP 4418 E7 220 Volt 380 Volt 415 Volt D90CA 767 E D91CA 823 E D92CA 926 E7 575 Volt (can be used at 208/230/460 Volts) 8 5 D80CA 817 E D81CA 865 E D82CA 964 E7 Three Phase Torque Control 7 thru 40 Amps 208/230/460V 50/60 Hz. 7 thru 24 Amps 208/230/460/575V 50/60 Hz. Applications: Use with magnetic starter. A low cost way to reduce starting torque on three phase motors. An alternative to ballast resistors on cranes and conveyors. Suitable for reduced torque on start. Designed to be used with a magnetic contactor. Not suitable for starting high torque loads. Features: Two adjustable starting torque settings for reversing or two speed applications. Adjustable starting ramp time to 7 seconds. Amp Max at VAC Size Open/Panel - 208/230/460 Volts (Available in 1 and 12/3R enclosures) T70EA 458 E T71EA 476 E T72EA 509 E T73EA 543 E7 Open/Panel Volts (can be used at 208/230/460 Volts) T80EA 492 E T81EA 509 E T82EA 543 E7 Accessories Grinders Generators Mod Express Baldor Education Workshops Index Baldor District Offices 261

262 Soft Start & Dynamic Brakes Multipurpose Dynamic Brake Soft Starters & Dynamic Brakes HP V 50/60 Hz HP V 50/60 Hz Gearmotors and Gear Products Accessories Grinders Generators Mod Express Baldor Education Workshops Index Baldor District Offices Applications: Stopping coasting loads such as chippers, saws, cutting tools and conveyors. It can also be used to stop windmilling fans before starting. Features: The Multipurpose Brake is a microprocessor based solid state brake designed to eliminate the problems common to traditional DC injection brakes. To eliminate blown fuses and welded contacts, the microprocessor senses when AC is no longer present before turning on the braking. A faster zero speed sensing circuit turns off the braking as soon as the motor stops to reduce motor heating. Model # 208/230/460 VAC Hz.(1) BQ7-016-CP BQ7-030-CP BQ7-055-CP BQ7-080-CP BQ7-135-CP BQ7-160-CP BQ7-250-CP BQ7-420-CP BQ7-600-CP 230/460/575 VAC Hz.(1) BQ8-016-CP BQ8-030-CP BQ8-055-CP BQ8-080-CP BQ8-135-CP BQ8-160-CP BQ8-250-CP BQ8-420-CP BQ8-600-CP Output Ratings Input Rating Control Spec. Design Specifications Microprocessor based control SCR/Diode power circuit Line contactor voltage sensing circuit Zero speed sensing Four braking time ranges Three operating modes Two adjustable braking magnitude potentiometers Environmental and Operating Conditions 40 degrees C 1000 feet elevation Open panel design 208, 230, 460, 575 volt input line voltage 50/60 Hz input frequency Control voltage 120 VAC 230 VAC Rating 460 VAC VAC Current Rating Derate Above 1000m (3300 Ft.) decrease amp rating 1% for each additional 100m (330 ft.) Above 45 (115 F) decrease amp rating 1.5% for additional C (0.84%/ F) Frequency Hz. ±5% Voltage control board 115 VAC +10% to -15% Phase Three Phase Control Type Microprocessor Based Control Method Common Anode SCR and diode to achieve DC Control Power External control transformer (suppled with certain models) 115 VAC Hz. to the control board Power Consumption 1.5 VA by the control board Operating Modes Master mode (brake controls starting and stopping of motor) Prestop mode (prestop a windmilling load) Basic mode (for replacement of existing dynamic brake) Brake Timer Ranges 1-17 seconds; seconds; seconds; seconds Zero Speed Sensor Selectable (brake disengages when motor stops rotating) M Contact Rating 10 amp at 125 VAC Brake Magnitudes Two adjustable brake magnitudes Status LEDs Power/Ready/Run/Braking Peak Inverse Voltage 460 VAC controls V; 575 VAC controls V Heat Loss 1 watt per amp while braking Diagnostics Error Indicators Improper line voltages; contactor failed to open; Brake contactor failed to open; Improper line frequency Dimensions Height x Width x Depth x x x x 6 21 x 21 x 8 33 x 33 x 9.75 Ambient Conditions Temperature Enclosed 0-45 C (32 to 113 F) open/panel 0 to 50 C (32 to 122 F) Protective Features Shorted SCR protection terminal voltage sensing Time delay to allow motor flux to collapse starter interlock contact NOTE: (1) For 50 Hz. applications use the brakes without a transformer and supply a separate 115 VAC supply to the brake control board and contactor. The brake can also be ordered as a BQ9 - XXX - XX for 380/400/415 VAC applications. It will have the control transformer mounted on the panel. 262

263 Multipurpose Dynamic Brake Soft Starters & Dynamic Brakes Amp Max at VAC Size Open/Panel - 208/230/460 Volts BQ7-016-CP 1058 E BQ7-030-CP 1124 E BQ7-055-CP 1482 E BQ7-080-CP 2222 E BQ7-135-CP 3556 E BQ7-160-CP 4173 E BQ7-250-CP 5060 E BQ7-420-CP 7097 E BQ7-600-CP E /230/460 Volts BQ7-016-CC 1193 E BQ7-030-CC 1259 E BQ7-055-CC 1617 E BQ7-080-CC 2358 E BQ7-135-CC 3850 E BQ7-160-CC 4468 E BQ7-250-CC 5357 E BQ7-420-CC 8701 E BQ7-600-CC E7 Application Notes Soft Starters & Dynamic Brakes Gearmotors and Gear Products Accessories Grinders Generators Stopping Time Sizing Holding Brake Types Brake Sizing The Baldor Dynamic Brake can stop the motor faster than the motor will start (at full volts). However, this could damage the motor. It is best that the motor should not stop any faster than the motor starts. A dynamic brake should never be set to stop a load faster than the load starts. Stopping the motor too fast or too frequently can cause motor overheating and possible failure. Each stop with a dynamic brake should be treated as a start for calculating duty cycle and for sizing the motor. The brake does not have a duty cycle limit. A solid state brake is not a substitute for a mechanical holding brake. The Multipurpose Brake has been designed to operate on 3-phase induction motors. Use the motor FLA and operating voltage to size the brake. All Baldor Multipurpose Brakes can be used on high inertia loads. Extended stopping times are available for use on high inertia loads. WARNING: A DC injection brake is not a replacement for a mechanical or safety brake for emergency stopping Mod Express Baldor Education Workshops Index Baldor District Offices 263

264 Soft Start & Dynamic Brakes Gearmotors and Gear Products Single Phase - Right Angle - TEFC and TENV 1/50 thru 1 Gearmotors and Speed Reducers Applications: General purpose fixed speed including conveyors, material handling equipment and packaging machinery. Features: Induction hardened and ground steel worm, bronze gearing, internal expansion bladder and Mobil SHC634 synthetic oil, ball bearing motor construction, optional conduit box (BKP2400) available for 24 type motors. Accessories Grinders Generators Mod Express Baldor Education Workshops Index Baldor District Offices GC24322 Shown Input Output 50/60 Hz Gear Ratio Max. Safe Torque In. Lbs. No. NOTE: [A] Molded case polypropylene capacitors supplied loose for customer mounting. [B] Split phase, capacitor not required, starting relay supplied loose for customer mounting. [D] Capacitor start, induction run. Gear styles FTA, DB & EB lubricated with Mobil SHC007. All right angle gearmotors have double output shafts except Style K which has a single output shaft left side facing gearhead. Vertical motor below gearhead not recommended. Avoiding those positions where the high speed oil seal is immersed in oil, will provide greater security against high speed input seal wear. Type & Gear Style Capacitor Rating Type 115 VAC 50/60 Hz - TENV 1/50 59/ :1 7.5 GC DS 2412C-FTA 7 [A] 1/20 35/42 40:1 30 GC DS 2416C-BB 10 [A] 1/20 68/ :1 24 GC DS 2416C-BB 10 [A] 1/20 133/160 10:1 14 GC DS 2416C-BB 10 [A] 1/12 23/ :1 75 GC DS 2420C-CB 10 [A] 1/12 41/ :1 62 GC DS 2420C-CB 13 [A] 1/12 60/ GC DS 2420C-CB 13 [A] 1/12 123/148 11:1 25 GC DS 2420C-CB 13 [A] 1/ /14 117:1 40 GC DS 2412C-DB 10 [A] 1/13 7.7/ :1 175 GC DS 2416C-EB 10 [A] 1/ /16 100:1 100 GC DS 2416C-EB 10 [A] 1/8 30/37 45:1 125 GC DS 2524S-JK 16 [B] 1/8 43/50 33:1 100 GC DS 2524S-JK 16 [B] 1/8 62/ :1 79 GC DS 2524S-JK 16 [B] 1/8 126/152 11:1 41 GC DS 2524S-JK 16 [B] 115 VAC 50/60 Hz-TEFC & TENV 1/15 23/28 60:1 45 GC DS 2416C-K 11 [A] 1/15 35/42 40:1 49 GC DS 2416C-K 11 [A] 1/15 68/ :1 32 GC DS 2416C-K 11 [A] 1/15 135/165 10:1 18 GC DS 2416C-K 11 [A] 1/8 34/41 40:1 90 GC DS 2520C-K 16 [A] 1/8 46/55 30:1 78 GC DS 2520C-K 16 [A] 1/8 69/82 20:1 57 GC DS 2520C-K 16 [A] 1/8 130/160 10:1 33 GC DS 2520C-K 16 [A] 1/8 36/43 40:1 90 GC DS 2520S-K 15 [B] 1/8 48/57 30:1 78 GC DS 2520S-K 15 [B] 1/8 71/86 20:1 57 GC DS 2520S-K 15 [B] 1/8 140/170 10:1 33 GC DS 2520S-K 15 [B] 1/6 33/41 40:1 130 GC DS 2524C-K 15 [A] 1/6 67/82 20:1 75 GC DS 2524C-K 15 [A] 1/6 135/165 10:1 43 GC DS 2524C-K 15 [A] 1/6 265/320 5:1 23 GC DS 2524C-K 15 [A] 1/6 35/42 40:1 130 GC DS 2528L-K 21 [D] 1/6 71/85 20:1 75 GC DS 2528L-K 21 [D] 1/6 135/165 10:1 43 GC DS 2528L-K 21 [D] 1/6 280/335 5:1 23 GC DS 2528L-K 21 [D] 264

265 Gearmotors and Speed Reducers Single Phase - Right Angle -TEFC and TENV continued... Soft Starters & Dynamic Brakes GHL37530 Shown Input Output 60 Hz Gear Ratio Max. Safe Torque In. Lbs. No. Type & Gear Style Capacitor Rating Type 115 VAC 50/60 Hz-TEFC & TENV 1/ :1 125 GC DS 3324S-JK 26 [B] 1/ :1 70 GC DS 3324S-JK 26 [B] 1/ :1 600 GHL DS 3421L-H 38 [D] 1/ :1 350 GHL DS 3421L-H 38 [D] 1/ :1 250 GHL DS 3421L-H 38 [D] 1/ :1 150 GHL DS 3421L-H 38 [D] 3/ :1 550 GHL DS 3428LC-H 50 [D1] 3/ :1 420 GHL DS 3428LC-H 50 [D1] 3/ :1 230 GHL DS 3428LC-H 50 [D1] :1 750 GHL DS 3524L-H 55 [D] :1 550 GHL DS 3524L-H 55 [D] :1 300 GHL DS 3524L-H 55 [D] NOTE: [A] Molded case polypropylene capacitors supplied loose for customer mounting. [B] Split phase, capacitor not required, starting relay supplied loose for customer mounting. [D] Capacitor start, induction run. [D1] Capacitor start, capacitor run. All right angle gearmotors have double output shafts except Style K which has a single output shaft left side facing gearhead, style "H" has hollow bore (shaft mount). Vertical motor below gearhead not recommended. Avoiding those positions where the high speed oil seal is immersed in oil, will provide greater security against high speed input seal wear. Gearmotors and Gear Products Accessories Grinders Generators Inverter Gearmotor - Right Angle and Parallel Shaft -TEFC IDGM2505 Shown Input Output 60 Hz. Gear Ratio Speed Range 3/8 Applications: Ideally suited for conveyors, material handing, packaging equipment applications requiring adjustable speed and no maintenance. Available in a broad range of gear ratios meeting your demanding application needs. Features: ISR (Inverter Spike Resistant) magnet wire for increased protection against voltage spikes and corona damage, IP44 protection, Designed for use on Baldor Series 15J, 15P and Series 5 Inverters operating on 230 volts. Both Parallel shaft and Right Angle gearmotors are lubricated for life and require no routine maintenance. Right Angle gearmotors feature our internal oil expansion bladder which eliminates the need for a breather while allowing the gearmotor to be mounted in any position*. Maximum Safe Torque 60 Hz NOTE: *Avoiding those positions where the high speed oil seal is immersed in oil, will provide greater security against high speed input seal wear. Vertical motor below gearbox is possible with modification, contact Baldor for details. Type & Gear Style Right Angle 3/ : IDGM E2 2528M-K 22 C 3/ : IDGM E2 2528M-K 22 C 3/ : IDGM E2 2528M-K 22 C 3/ : IDGM E2 2528M-K 22 C 3/ : IDGM E2 2528M-K 22 C 3/ : IDGM E2 2528M-K 22 C Parallel Shaft 3/ : IDGMP E2 2528M-PSLH 20 C 3/ : IDGMP E2 2528M-PSLH 20 C 3/ : IDGMP E2 2528M-PSLH 20 C 3/ : IDGMP E2 2528M-PSLH 20 C Volt Code Mod Express Baldor Education Workshops Index Baldor District Offices 265

266 Soft Start & Dynamic Brakes Gearmotors and Gear Products Three Phase - Right Angle - TEFC and TENV 1/12 thru 1 Gearmotors and Speed Reducers Applications: General purpose fixed speed including conveyors, material handling equipment and packaging machinery. Features: Induction hardened and ground steel worm, bronze gearing, internal expansion bladder and Mobil SHC634 synthetic oil, ball bearing motor construction. Accessories Grinders Generators Mod Express Baldor Education Workshops Index Baldor District Offices GM2503 Shown Input Output 50/60 Hz. Gear Ratio Max. Safe Torque In. Lbs. NOTE: 60 Hz: E= /460, E1 = /460 volts, U=190/380// /460 volts. All right angle gearmotors have double output shafts except Style K and JH which has a single output shaft left side facing gearhead. Style H has hollow bore. Vertical motor below gearhead not recommended. Avoiding those positions where the high speed oil seal is immersed in oil, will provide greater security against high speed input seal wear. Type & Gear Style 1/12 95/115 15:1 30 GM DS 2516M-BA 15 U 1/8 143/174 10:1 30 GM DS 2516M-BA 15 U 1/ :1 27 GM DS 2512M-BA 15 E 1/8 285/345 5:1 15 GM DS 2516M-BA 15 U 1/ :1 175 GM DS 2516M-EB 15 E 1/ :1 125 GM DS 2516M-EB 15 E 1/ :1 42 GM DS 2512M-CA 24 E 1/ :1 125 GM DS 2520M-JK 24 E 1/ :1 85 GM DS 2520M-JK 24 E 1/ :1 75 GM DS 2520M-JK 24 E 1/4 35/ :1 170 GM DS 2524M-K 24 U 1/4 70/85 20:1 112 GM DS 2524M-K 24 U 1/4 140/170 10:1 72 GM DS 2524M-K 24 U 1/4 279/340 5:1 36 GM DS 2524M-K 24 U 1/ :1 256 GM DS 2528M-JH 28 E 1/ :1 230 GM DS 2528M-JH 28 E 1/ :1 155 GM DS 2528M-JH 28 E 1/ :1 90 GM DS 2528M-JH 28 E 1/ :1 295 GM DS 3320M-JH 35 E 1/ :1 280 GM DS 3320M-JH 35 E 1/ :1 200 GM DS 3320M-JH 35 E 1/ :1 135 GM DS 3320M-JH 35 E 1/ :1 600 GHM DS 3416M-H 40 E1 1/ :1 350 GHM DS 3416M-H 40 E1 1/ :1 200 GHM DS 3416M-H 40 E1 1/ :1 135 GHM DS 3416M-H 40 E1 3/ :1 550 GHM DS 3420M-H 42 E 3/ :1 420 GHM DS 3420M-H 42 E 3/ :1 230 GHM DS 3420M-H 42 E :1 750 GHM DS 3426M-H 45 E :1 550 GHM DS 3426M-H 45 E :1 300 GHM DS 3426M-H 45 E Voltage Code 266

267 Single Phase - Parallel Shaft - TEFC and TENV GCP24232 Shown Input Output 50/60 Hz. Gear Ratio Max. Safe Torque In. Lbs. 1/40 thru 1/2 Gearmotors and Speed Reducers Applications: Conveyors, packaging machines, machine tools and laboratory equipment requiring constant speed. Features: Steel gearing, synthetic lubrication, needle bearings on output shaft, ball bearings on intermediate stages, ball bearing motor construction, optional bases available for foot mounting. Conduit box (BKP2400) available for 24 type motors. Single Phase VAC 50/60 Hz (TENV) 1/40 7.6/ :1 120 GCP DS 2412C-PSSH 10 [A] 1/ /18 90:1 120 GCP DS 2416C-PSSH 10 [A] 1/25 23/ : GCP DS 2416C-PSSH 10 [A] 1/12 45/ : GCP DS 2424C-PSSH 10 [A] 1/12 68/ : GCP DS 2424C-PSSH 10 [A] 1/12 90/109 15: GCP DS 2424C-PSSH 10 [A] 1/12 136/163 10: GCP DS 2424C-PSSH 10 [A] 1/12 272/326 5: GCP DS 2424C-PSSH 10 [A] 1/15 15/18 90:1 237 GCP DS 2424C-PSM 14 [A] 1/12 23/27 60:1 167 GCP DS 2424C-PSM 14 [A] 1/9 43/36 40:1 149 GCP DS 2524S-PSM 14 [B] 1/9 47/57 30:1 112 GCP DS 2524S-PSM 14 [B] 1/9 84/70 20:1 74 GCP DS 2524S-PSM 14 [B] 1/9 92/111 15:1 57 GCP DS 2524S-PSM 14 [B] 1/9 138/166 10:1 38 GCP DS 2524S-PSM 14 [B] 1/9 275/330 5:1 19 GCP DS 2524S-PSM 14 [B] 1/25 4.5/ :1 325 GCP DS 2416C-PSL 15 [A] 1/25 7.6/ :1 235 GCP DS 2416C-PSL 15 [A] 1/12 11/ :1 330 GCP DS 2424C-PSL 15 [A] 1/12 15/ :1 250 GCP DS 2424C-PSL 15 [A] 1/8 23/28 60:1 270 GCP DS 2524S-PSL 18 [B] 1/8 45/55 30:1 135 GCP DS 2524S-PSL 18 [B] 1/8 71/85 20:1 92 GCP DS 2524S-PSL 18 [B] 1/8 141/170 10:1 46 GCP DS 2524S-PSL 18 [B] 1/8 283/340 5:1 23 GCP DS 2524S-PSL 18 [B] Single Phase VAC 60 Hz (TENV) 1/ :1 164 GCP DS 3316C-PSL 24 [A] 1/ :1 112 GCP DS 3316C-PSL 24 [A] 1/ :1 56 GCP DS 3316C-PSL 24 [A] Capacitor Start - Single Phase - 115/ VAC 60 Hz (TEFC) 1/ :1 483 GLP DS 3320L-PSLH 25 [C] 1/ :1 438 GLP DS 3324L-PSLH 25 [C] 1/ :1 320 GLP DS 3324L-PSLH 25 [C] 1/ :1 218 GLP DS 3324L-PSLH 25 [C] 1/ :1 109 GLP DS 3324L-PSLH 25 [C] 1/ :1 55 GLP DS 3324L-PSLH 25 [C] 1/ :1 484 GLP DS 3328L-PSLH 25 [C] 1/ :1 326 GLP DS 3328L-PSLH 25 [C] 1/ :1 245 GLP DS 3328L-PSLH 25 [C] 1/ :1 164 GLP DS 3328L-PSLH 25 [C] NOTE: [A] Molded case polypropylene capacitors supplied loose for customer mounting. Refer to optional mounting kits on page 294. [B] Split phase, capacitor not required, starting relay supplied loose for customer mounting. [C] Items are capacitor start. [D] Capacitor start, induction run. [D1] Capacitor start, capacitor run. Vertical motor below gearhead not recommended. Avoiding those positions where the high speed oil seal is immersed in oil, will provide greater security against high speed input seal wear. Type & Gear Style Capacitor Rating Type Soft Starters & Dynamic Brakes Gearmotors and Gear Products Accessories Grinders Generators Mod Express Baldor Education Workshops Index Baldor District Offices 267

268 Soft Start & Dynamic Brakes Gearmotors and Gear Products Accessories Grinders Generators Mod Express Baldor Education Workshops Index Baldor District Offices 268 Three Phase - Parallel Shaft - TEFC GMP3330 Shown Input Output Gear Ratio Direct Current Permanent Magnet - Right Angle, TENV Max. Safe Torque In. Lbs. 1/3 thru 1/2 Gearmotors and Speed Reducers Applications: Conveyors, packaging machines, machine tools and laboratory equipment requiring constant speed. Features: Heavy duty helical steel gearing, synthetic lubrication, needle bearings and thrust bearings on output shaft, ball bearings on intermediate stages, ball bearing motor construction, optional base available for foot mounting. 1/50 thru 1/2 Applications: Conveyors, medical and laboratory equipment, printing presses, commercial ovens, machine tools and other applications requiring adjustable speed. Features: Induction hardened and ground steel worm, bronze gearing, internal expansion bladder and Mobil SHC634 synthetic oil, ball bearing motor construction. NOTE: All right angle gearmotors have double output shafts except style K and JH, which have a single output shaft left side facing gearhead. Vertical motor below gearhead not recommended. Avoiding those positions where the high speed oil seal is immersed in oil, will provide greater security against high speed input seal wear. Type & Gear Style Three Phase /460 VAC 60 Hz (TEFC) 1/ :1 320 GMP DS 3320M-PSLH 27 1/ :1 218 GMP DS 3320M-PSLH 27 1/ :1 109 GMP DS 3320M-PSLH 27 1/ :1 55 GMP DS 3320M-PSLH 27 1/ :1 627 GMP DS 3320M-PSLH 27 1/ :1 484 GMP DS 3320M-PSLH 27 1/ :1 326 GMP DS 3320M-PSLH 27 1/ :1 164 GMP DS 3320M-PSLH 27 GP Shown Input Output Base Speed Gear Ratio Max. Safe Torque In. Lbs. Type & Gear Style Voltage D.C. Armature Amperage Armature Foot Mount - 90 Volts 1/ :1 15 GP DS 2308P-GNA / :1 75 GP DS 2308P-DA / :1 75 GP DS 2308P-DA / :1 66 GP DS 2314P-DA / :1 64 GP DS 2314P-DA / :1 150 GP DS 2412P-EB / :1 175 GP DS 2424P-EB / :1 7.3 GP DS 2308P-FTA / :1 11 GP DS 2314P-FTA / :1 6 GP DS 2314P-FTA / :1 5.1 GP DS 2314P-FTA / :1 30 GP DS 2314P-BA / :1 33 GP DS 2318P-BA / :1 27 GP DS 2318P-BA / :1 22 GP DS 2318P-BA / :1 17 GP DS 2318P-BA / :1 45 GP DS 2314P-CB / :1 38 GP DS 2314P-CB / :1 57 GP DS 2318P-CB / :1 48 GP DS 2318P-CB / :1 33 GP DS 2318P-CB

269 Gearmotors and Speed Reducers Direct Current Permanent Magnet - Right Angle, TENV continued Input Output Base Speed Gear Ratio Max. Safe Torque In. Lbs. NOTE: Supplied with type SJO, three foot 18/3 AWG grounded cord, except 1/3 and 1/2 which have 12" leads and conduit box. See notes on pages 8 and 9, and inside back flap. Refer to page 294 for conduit box kits, mounting adapters and brackets, and UL and CSA approvals on motors and gearmotors. All right angle gearmotors have double output shafts except style K and JH, which have a single output shaft left side facing gearhead. Vertical motor below gearhead not recommended. Avoiding those positions where the high speed oil seal is immersed in oil, will provide greater security against high speed input seal wear. Type & Gear Style Voltage D.C. Armature Amperage Armature Foot Mount - 90 Volts continued 1/ :1 73 GP DS 125-K / :1 39 GP DS 125-K / :1 22 GP DS 125-K / :1 10 GP DS 125-K / :1 135 GP DS 135-K / :1 111 GP DS 135-K / :1 88 GP DS 135-K / :1 48 GP DS 135-K / :1 24 GP DS 135-K / :1 120 GP DS 2424P-JK / :1 100 GP DS 2424P-JK / :1 75 GP DS 2424P-JK / :1 60 GP DS 2424P-JK / :1 32 GP DS 2424P-JK / :1 112 GP DS 2424P-JK / :1 120 GP DS 2424P-JK / :1 100 GP DS 2424P-JK / :1 75 GP DS 2424P-JK / :1 32 GP DS 2424P-JK / :1 150 GP DS 2532P-JH / :1 137 GP DS 2532P-JH / :1 95 GP DS 2532P-JH / :1 65 GP DS 2532P-JH / :1 234 GP DS 3327P-JH / :1 215 GP DS 3327P-JH / :1 145 GP DS 3327P-JH / :1 100 GP DS 3327P-JH Foot Mount Volts 1/ :1 75 GP DS 2314P-DA / :1 75 GP DS 2314P-DA / :1 66 GP DS 2314P-DA / :1 64 GP DS 2314P-DA / :1 175 GP DS 2424P-EB / :1 33 GP DS 2318P-BA / :1 28 GP DS 2318P-BA / :1 17 GP DS 2318P-BA / :1 57 GP DS 2318P-CB / :1 48 GP DS 2318P-CB / :1 76 GP DS 2318P-CB / :1 120 GP DS 2420P-JK / :1 100 GP DS 2420P-JK / :1 75 GP DS 2420P-JK / :1 60 GP DS 2420P-JK / :1 32 GP DS 2420P-JK / :1 135 GP DS 2424P-JK / :1 120 GP DS 2424P-JK / :1 100 GP DS 2424P-JK / :1 75 GP DS 2424P-JK / :1 32 GP DS 2424P-JK Soft Starters & Dynamic Brakes Gearmotors and Gear Products Accessories Grinders Generators Mod Express Baldor Education Workshops Index Baldor District Offices 269

270 Soft Start & Dynamic Brakes Gearmotors and Gear Products Direct Current Permanent Magnet - Right Angle - TENV GPF13514 Shown 1/5 thru 1/4 Gearmotors and Speed Reducers Applications: Conveyors, medical and laboratory equipment, printing presses, commercial ovens, machine tools and many other applications requiring adjustable speed. Features: Flange mount, induction hardened and ground steel worm, bronze gearing, internal expansion bladder and Mobil SHC634 synthetic oil, ball bearing motor construction. Accessories Grinders Generators Mod Express Baldor Education Workshops Index Baldor District Offices 270 Input Output Base Speed Gear Ratio Max. Safe Torque In. Lbs. Direct Current Permanent Magnet - Parallel Shaft - TENV 1/45 thru 1/2 Applications: Conveyors, medical and laboratory equipment, printing presses, commercial ovens, machine tools and many other applications requiring adjustable speed. Features: Steel gearing, synthetic lubrication, needle bearings on output shaft, ball bearings on intermediate stages, ball bearing motor construction, optional bases available for foot mounting. NOTE: Supplied with type SJO, three foot 18/3 AWG grounded cord. See notes on pages 8 and 9, and inside back flap. Refer to page 294 for conduit box kits, mounting adapters and brackets, and UL and CSA approvals on motors and gearmotors. Vertical motor below gearhead not recommended. Avoiding those positions where the high speed oil seal is immersed in oil, will provide greater security against high speed input seal wear. Type & Gear Style Voltage D.C. Armature Amperage Armature Flange Mount - 90 Volts 1/ : GPF DS 135-JAF / : GPF DS 135-JAF / : GPF DS 135-JAF / : GPF DS 135-JAF Flange Mount Volts 1/ : GPF DS 135-JAF / : GPF DS 135-JAF GPP Shown Input Output Base Speed Gear Ratio Max. Safe Torque In. Lbs. Type & Gear Style Voltage D.C. Armature Amperage Armature 90 Volts 1/ :1 100 GPP DS 2308P-PSSH / :1 118 GPP DS 2308P-PSSH / :1 40 GPP DS 2308P-PSSH / :1 100 GPP DS 2318P-PSSH / :1 50 GPP DS 2318P-PSSH / :1 9.5 GPP DS 2308P-PSSH / :1 112 GPP DS 2412P-PSSH / :1 83 GPP DS 2412P-PSSH / : GPP DS 2412P-PSSH / :1 43 GPP DS 2412P-PSSH / : GPP DS 2412P-PSSH / :1 197 GPP DS 2318P-PSM / :1 180 GPP DS 2318P-PSM / :1 165 GPP DS 2416P-PSM / :1 116 GPP DS 2416P-PSM / :1 90 GPP DS 2416P-PSM / :1 58 GPP DS 2416P-PSM / :1 45 GPP DS 2416P-PSM / :1 30 GPP DS 2416P-PSM / :1 15 GPP DS 2416P-PSM

271 Gearmotors and Speed Reducers Direct Current Permanent Magnet - Parallel Shaft - TENV continued Input Output Base Speed Gear Ratio Max. Safe Torque In. Lbs. NOTE: Supplied with type SJO, three foot 18/3 AWG grounded cord, except 1/3 and 1/2 which have 12" leads and conduit box. See page 294 for optional mounting brackets. See notes on pages 8 and 9, and inside back flap. Vertical motor below gearhead not recommended. Avoiding those positions where the high speed oil seal is immersed in oil, will provide greater security against high speed input seal wear. Type & Gear Style Voltage D.C. Armature Amperage Armature 90 Volts Continued... 1/ :1 330 GPP DS 2424P-PSL / :1 330 GPP DS 2424P-PSL / :1 365 GPP DS 2424P-PSL / :1 365 GPP DS 2424P-PSL / :1 390 GPP DS 2424P-PSL / :1 280 GPP DS 2424P-PSL / :1 250 GPP DS 2424P-PSL / :1 200 GPP DS 2424P-PSL / :1 150 GPP DS 2424P-PSL / :1 100 GPP DS 2424P-PSL / :1 75 GPP DS 2424P-PSL / :1 50 GPP DS 2424P-PSL / :1 25 GPP DS 2424P-PSL / :1 320 GPP DS 2532P-PSLH / :1 164 GPP DS 2532P-PSLH / :1 55 GPP DS 2532P-PSLH / :1 337 GPP DS 3327P-PSLH / :1 171 GPP DS 3327P-PSLH / :1 57 GPP DS 3327P-PSLH Volts 1/ :1 118 GPP DS 2314P-PSSH / :1 112 GPP DS 2420P-PSSH / :1 50 GPP DS 2318P-PSSH / : GPP DS 2416P-PSSH / :1 174 GPP DS 2416P-PSM / :1 87 GPP DS 2416P-PSM / :1 30 GPP DS 2416P-PSM / : GPP DS 2416P-PSM / :1 330 GPP DS 2424P-PSL / :1 365 GPP DS 2424P-PSL / :1 365 GPP DS 2424P-PSL / :1 280 GPP DS 2424P-PSL / :1 200 GPP DS 2424P-PSL / :1 155 GPP DS 2424P-PSL / :1 100 GPP DS 2424P-PSL / :1 75 GPP DS 2424P-PSL / :1 50 GPP DS 2424P-PSL / :1 25 GPP DS 2424P-PSL / :1 320 GPP DS 3327P-PSLH / :1 164 GPP DS 3327P-PSLH / :1 55 GPP DS 3327P-PSLH / :1 337 GPP DS 3327P-PSLH / :1 171 GPP DS 3327P-PSLH / :1 57 GPP DS 3327P-PSLH Soft Starters & Dynamic Brakes Gearmotors and Gear Products Accessories Grinders Generators Mod Express Baldor Education Workshops Index Baldor District Offices 271

272 Soft Start & Dynamic Brakes Gearmotors and Gear Products Accessories Grinders Generators Mod Express Baldor Education Workshops Index Baldor District Offices 900 Series - Right Angle - Quill Type Solid Shaft Nominal 1750 In NOTE: Gear Ratio GF1018AG Shown Continuous Duty Output Torque (In-Lbs) Based on Service Class I Torque Ratings (1.0 Service Factor) Service Class II Torque Ratings ( 1.4 Service Factor) Service Class III Torque Ratings ( 2.0 Service Factor) Gearmotors and Speed Reducers 1.33 thru 3.75 CD 56C thru 210TC Applications: Ideal for conveyors, material handling, textile machines, packaging machinery. etc. (slow speed and high torque). Features: Heavy duty cast iron housing, chill cast bronze gearing, precision ground hardened worm, ball bearing on input shaft, tapered roller bearings on output shaft. Industry-standard mounting dimensions. Pre-filled with food grade (H1) Klubersynth UH synthetic oil, sealed housing provides maintenance-free lubed for life operation. Vertical motor below gearhead not recommended. Avoiding those positions where the high speed oil seal is immersed in oil, will provide greater security against high speed input seal wear. Replacement oil 1 Qt P/N MJ0006A05SP (Klubersynth UH ) Assembly Types Max Input Max Output Torque Rating In-Lbs Mount Style C F B5-G GF0513AG 341 GB C F B5-J GF0513AJ 341 GB C F B5-G GF0515AG 366 GB TC F B7-G GF0515BG 366 GB C F B5-H GF0515AH 386 GB C F B5-G GF0518AG 374 GB : TC F B7-G GF0518BG 374 GB TC F B7-G GF0521BG 468 GB TC F B7-J GF0521BJ 468 GB TC F-921G-05-B7-G GF05G21BG 468 GB TC F B9-G GF0524CG 553 GB TC F B9-G GF0526CG 642 GB TC F B9-G GF0530CG 873 GB TC F B11-H GF0538DH 1222 GB : TC F B9-G GF0830CG 873 GB C F B5-G GF1013AG 341 GB C F B5-J GF1013AJ 341 GB C F B5-H GF1013AH 361 GB C F B5-G GF1015AG 366 GB TC F B7-G GF1015BG 366 GB C F B5-H GF1015AH 386 GB 25 10: C F B5-G GF1018AG 374 GB C F B5-J GF1018AJ 374 GB C F B5-H GF1018AH 396 GB TC F B7-G GF1018BG 374 GB C F B5-G GF1021AG 468 GB C F B5-J GF1021AJ 468 GB C F-921G-10-B5-G GF10G21AG 468 GB 30 Ap x G H J 272

273 Gearmotors and Speed Reducers 900 Series - Right Angle - Quill Type - Solid Shaft continued Nominal 1750 In NOTE: Gear Ratio : : :1 Continuous Duty Output Torque (In-Lbs) Based on Service Class I Torque Ratings (1.0 Service Factor) Service Class II Torque Ratings ( 1.4 Service Factor) Service Class III Torque Ratings ( 2.0 Service Factor) See notes on pages 8 and 9, and inside back flap. Vertical motor below gearhead not recommended. Avoiding those positions where the high speed oil seal is immersed in oil, will provide greater security against high speed input seal wear. Max Input Max Output Torque Rating In-Lbs Mount Style C F B5-H GF1021AH 494 GB TC F B7-G GF1021BG 468 GB TC F B7-G GF1024BG 553 GB TC F B7-G GF1026BG 642 GB TC F B9-G GF1026CG 642 GB TC F B9-G GF1030CG 873 GB TC F B9-G GF1032CG 947 GB TC F B11-G GF1038DG 1157 GB TC F B9-H GF1038CH 1222 GB C F B5-G GF1513AG 341 GB C F B5-J GF1513AJ 341 GB C F B5-H GF1513AH 361 GB C F B5-G GF1515AG 366 GB C F B5-H GF1515AH 386 GB C F B5-G GF1518AG 374 GB C F B5-J GF1518AJ 374 GB C F B5-H GF1518AH 396 GB C F B5-G GF1521AG 468 GB C F B5-J GF1521AJ 468 GB C F B5-H GF1521AH 494 GB TC F B7-G GF1521BG 468 GB C F B5-G GF1524AG 553 GB C F B5-J GF1524AJ 553 GB TC F B7-G GF1524BG 553 GB TC F B7-G GF1526BG 642 GB TC F B9-G GF1530CG 873 GB TC F B7-G GF1532BG 947 GB TC F B9-G GF1532CG 947 GB TC F B9-G GF1538CG 1157 GB TC F B9-H GF1538CH 1222 GB C F B5-G GF2013AG 341 GB C F B5-H GF2013AH 361 GB C F B5-G GF2015AG 366 GB C F B5-H GF2015AH 386 GB C F B5-G GF2018AG 374 GB C F B5-J GF2018AJ 374 GB C F B5-H GF2018AH 396 GB C F B5-G GF2021AG 468 GB C F B5-J GF2021AJ 468 GB C F-921G-20-B5-G GF20G21AG 468 GB 35 Ap x Soft Starters & Dynamic Brakes Gearmotors and Gear Products Accessories Grinders Generators Mod Express Baldor Education Workshops Index Baldor District Offices Assembly Types G H J 273

274 Soft Start & Dynamic Brakes Gearmotors and Gear Products Accessories Grinders Generators Mod Express Baldor Education Workshops Index Baldor District Offices Gearmotors and Speed Reducers 900 Series - Right Angle - Quill Type - Solid Shaft continued Nominal 1750 In Gear Ratio 88 20: : :1 Continuous Duty Output Torque (In-Lbs) Based on NOTE: Refer to Brochure CA1600 for Dimensions and Engineering Information. Service Class I Torque Ratings (1.0 Service Factor) Service Class II Torque Ratings ( 1.4 Service Factor) Service Class III Torque Ratings ( 2.0 Service Factor) Max Input Max Output Torque Rating In-Lbs Mount Style C F B5-H GF2021AH 494 GB TC F B7-G GF2021BG 468 GB TC F-921G-20-B7-G GF20G21BG 468 GB C F B5-G GF2024AG 553 GB TC F B7-G GF2024BG 553 GB C F B5-G GF2026AG 642 GB TC F B7-G GF2026BG 642 GB TC F B7-G GF2030BG 873 GB TC F B9-G GF2030CG 873 GB TC F B9-J GF2030CJ 873 GB TC F B7-G GF2032BG 947 GB TC F B9-G GF2032CG 947 GB TC F B9-G GF2038CG 1157 GB C F B5-G GF2513AG 341 GB C F B5-G GF2515AG 366 GB C F B5-H GF2515AH 386 GB C F B5-G GF2518AG 374 GB C F B5-J GF2518AJ 374 GB C F B5-G GF2521AG 468 GB C F B5-J GF2521AJ 468 GB C F-921G-25-B5-G GF25G21AG 468 GB TC F B7-G GF2524BG 553 GB TC F B7-G GF2526BG 642 GB C F B5-G GF2530AG 873 GB TC F B7-G GF2530BG 873 GB TC F B7-G GF2532BG 947 GB TC F B9-H GF2538CH 1222 GB C F B5-G GF3013AG 341 GB C F B5-H GF3013AH 361 GB C F B5-G GF3015AG 366 GB C F B5-H GF3015AH 386 GB C F B5-G GF3018AG 374 GB C F B5-J GF3018AJ 374 GB C F B5-H GF3018AH 396 GB C F B5-G GF3021AG 468 GB C F B5-J GF3021AJ 468 GB C F B5-H GF3021AH 494 GB C F-921G-30-B5-G GF30G21AG 468 GB C F B5-G GF3024AG 553 GB C F B5-J GF3024AJ 553 GB TC F B7-G GF3024BG 553 GB C F B5-G GF3026AG 642 GB TC F B7-G GF3026BG 642 GB C F B5-G GF3030AG 873 GB C F B5-J GF3030AJ 873 GB TC F B7-G GF3030BG 873 GB 68 Ap x See notes on pages 8 and 9, and inside back flap. Vertical motor below gearhead not recommended. Avoiding those positions where the high speed oil seal is immersed in oil, will provide greater security against high speed input seal wear. 274

275 Gearmotors and Speed Reducers 900 Series - Right Angle - Quill Type - Solid Shaft continued Nominal 1750 In NOTE: Gear Ratio 58 30: : : :1 Continuous Duty Output Torque (In-Lbs) Based on Service Class I Torque Ratings (1.0 Service Factor) Service Class II Torque Ratings ( 1.4 Service Factor) Service Class III Torque Ratings ( 2.0 Service Factor) See notes on pages 8 and 9, and inside back flap. Vertical motor below gearhead not recommended. Avoiding those positions where the high speed oil seal is immersed in oil, will provide greater security against high speed input seal wear. Max Input Max Output Torque Rating In-Lbs Mount Style TC F B7-G GF3032BG 947 GB TC F B9-G GF3038CG 1157 GB TC F B9-H GF3038CH 1222 GB C F BG-G GF4013AG 341 GB C F B5-H GF4013AH 361 GB C F B5-G GF4015AG 366 GB C F B5-J GF4015AJ 366 GB C F B5-G GF4018AG 374 GB C F B5-J GF4018AJ 374 GB C F B5-G GF4021AG 468 GB C F B5-J GF4021AJ 468 GB C F B5-G GF4024AG 553 GB C F B5-J GF4024AJ 553 GB C F B5-H GF4024AH 584 GB C F B5-G GF4026AG 642 GB C F B5-J GF4026AJ 642 GB TC F B7-G GF4026BG 642 GB C F B5-G GF4030AG 873 GB TC F B7-G GF4030BG 873 GB TC F B7-G GF4032BG 947 GB TC F B9-G GF4038CG 1157 GB TC F B9-H GF4038CH 1222 GB C F B5-G GF5013AG 341 GB C F B5-H GF5013AH 361 GB C F B5-G GF5015AG 366 GB C F B5-G GF5018AG 374 GB C F B5-J GF5018AJ 374 GB C F B5-G GF5021AG 468 GB C F B5-J GF5021AJ 468 GB C F B5-H GF5021AH 494 GB C F B5-G GF5024AG 553 GB C F B5-G GF5026AG 642 GB TC F B7-G GF5026BG 642 GB C F B5-G GF5030AG 873 GB TC F B7-G GF5030BG 873 GB C F B5-G GF5032AG 947 GB TC F B7-G GF5032BG 947 GB TC F B7-G GF5038BG 1157 GB TC F B7-H GF5038BH 1222 GB C F B5-G GF6015AG 366 GB C F B5-H GF6015AH 386 GB C F B5-G GF6018AG 374 GB C F B5-J GF6018AJ 374 GB C F B5-H GF6018AH 396 GB 30 Ap x Soft Starters & Dynamic Brakes Gearmotors and Gear Products Accessories Grinders Generators Mod Express Baldor Education Workshops Index Baldor District Offices 275

276 Soft Start & Dynamic Brakes Gearmotors and Gear Products Accessories Grinders Generators Mod Express Baldor Education Workshops Gearmotors and Speed Reducers 900 Series - Right Angle - Quill Type - Solid Shaft continued Nominal 1750 In NOTE: Gear Ratio 29 60:1 Service Class I Torque Ratings (1.0 Service Factor) Service Class II Torque Ratings ( 1.4 Service Factor) Service Class III Torque Ratings ( 2.0 Service Factor) Suffix G = Left hand output facing input J = Right hand output facing input H = Double Output Shaft Continuous Duty Output Torque (In-Lbs) Based on See notes on pages 8 and 9, and inside back flap. Vertical motor below gearhead not recommended. Avoiding those positions where the high speed oil seal is immersed in oil, will provide greater security against high speed input seal wear. Max Input Max Output Torque Rating In-Lbs Mount Style C F B5-G GF6021AG 468 GB C F B5-H GF6021AH 494 GB C F B5-J GF6021AJ 468 GB C F B5-G GF6024AG 553 GB C F B5-J GF6024AJ 553 GB C F B5-G GF6026AG 642 GB C F B5-J GF6026AJ 642 GB C F B5-H GF6026AH 676 GB C F B5-G GF6030AG 873 GB TC F B7-G GF6030BG 873 GB C F B5-G GF6032AG 947 GB TC F B7-G GF6032BG 947 GB TC F B7-G GF6038BG 1157 GB TC F B7-H GF6038BH 1222 GB 126 Assembly Types Ap x G H J Index Baldor District Offices 276

277 900 Series - Right Angle - Quill Type Hollow Shaft Nominal 1750 In Gear Ratio GHF1018AH Shown Continuous Duty Output Torque (In-Lbs) Based on Gearmotors and Speed Reducers 1.33 thru 3.25 CD 56C thru 180TC Applications: Ideal for conveyors, material handling, textile machines, packaging machinery. etc. (slow speed and high torque). Features: Heavy duty cast iron housing, chill cast bronze gearing, precision ground hardened worm, ball bearing on input shaft, tapered roller bearings on output shaft. Industry-standard mounting dimensions. Pre-filled with food grade (H1) Klubersynth UH synthetic oil, sealed housing provides maintenance-free lubed for life operation : C HF B5-G GHF0513AH 450 GB C HF B5-H GHF0518AH 482 GB C HF B5-H GHF1018AH 482 GB : C HF B5-H GHF1021AH 572 GB TC HF B9-H GHF1030CH 1038 GB C HF B5-H GHF1513AH 450 GB C HF B5-H GHF1518AH 482 GB : C HF B5-H GHF1521AH 572 GB C HF B5-H GHF1524AH 687 GB TC HF B7-H GHF1530BH 1038 GB C HF B5-H GHF2013AH 450 GB C HF B5-H GHF2018AH 482 GB : C HF B5-H GHF2021AH 572 GB C HF B5-H GHF2024AH 687 GB C HF B5-H GHF2026AH 812 GB TC HF B7-H GHF2030BH 1038 GB C HF B5-H GHF3013AH 450 GB C HF B5-H GHF3018AH 482 GB C HF B5-H GHF3021AH 572 GB : C HF B5-H GHF3024AH 687 GB C HF B5-H GHF3026AH 812 GB TC HF B7-H GHF3030BH 1038 GB TC HF B7-H GHF3032BH 1125 GB C HF B5-H GHF4018AH 482 GB C HF B5-H GHF4021AH 572 GB C HF B5-H GHF4024AH 687 GB : C HF B5-H GHF4026AH 812 GB TC HF B7-H GHF4026BH 812 GB TC HF B7-H GHF4030BH 1038 GB TC HF B7-H GHF4032BH 1125 GB C HF B5-H GHF5013AH 450 GB C HF B5-H GHF5018AH 482 GB : C HF B5-H GHF5021AH 572 GB C HF B5-H GHF5024AH 687 GB C HF B5-H GHF5030AH 1038 GB C HF B5-H GHF5032AH 1125 GB C HF B5-H GHF6018AH 482 GB C HF B5-H GHF6021AH 572 GB : C HF B5-H GHF6024AH 687 GB C HF B5-H GHF6026AH 812 GB C HF B5-H GHF6030AH 1038 GB C HF B5-H GHF6032AH 1125 GB 95 NOTE: Service Class I Torque Ratings (1.0 Service Factor) Service Class II Torque Ratings ( 1.4 Service Factor) Service Class III Torque Ratings ( 2.0 Service Factor) See notes on pages 8 and 9, and inside back flap. Vertical motor below gearhead not recommended. Avoiding those positions where the high speed oil seal is immersed in oil, will provide greater security against high speed input seal wear. Max Input Max Output Torque Rating In-Lbs Mount Style Ap x Soft Starters & Dynamic Brakes Gearmotors and Gear Products Accessories Grinders Generators Mod Express Baldor Education Workshops Index Baldor District Offices 277

278 Soft Start & Dynamic Brakes Gearmotors and Gear Products Stainless Steel - Right Angle - Quill Type Solid Shaft Gearmotors and Speed Reducers 1.75 thru 2.62 CD 56C thru 140TC Applications: Baldor s all stainless speed reducers are easy to clean and sanitize, minimizing bacterial contamination for food processing equipment. Stainless steel provides the high protection for pharmaceutical and chemical processing applications where harsh chemicals and cleaning solutions can be extremely corrosive to aluminum, cast iron and other materials. Accessories SSGF1018BG Shown Features: Housing and covers are cast stainless steel to endure hostile environments. 304 stainless output shafts and all stainless steel hardware for long rust resistant life. O-ring sealed housing and motor interface helps keeps contaminants out. Pre-filled with food grade (H1) Klubersynth UH synthetic oil. Sealed housing provides maintenance-free lubed for life operation. BISSC certified (Baking Industry Sanitation Standards Committee). Grinders Generators Mod Express Baldor Education Workshops Index Baldor District Offices Nominal 1750 In NOTE: Gear Ratio 350 5: : : : : : : : :1 Continuous Duty Output Torque (In-Lbs) Based on Service Class I Torque Ratings (1.0 Service Factor) Service Class II Torque Ratings ( 1.4 Service Factor) Service Class III Torque Ratings ( 2.0 Service Factor) Max Input Max Output Torque Rating In-Lbs Mount Style C SSF B5-G SSGF0518AG 1141 GB TC SSF B7-G SSGF0518BG 1141 GB TC SSF B7-G SSGF0521BG 1334 GB TC SSF B7-G SSGF0526BG 1879 GB C SSF B5-G SSGF1018AG 1141 GB TC SSF B7-G SSGF1018BG 1141 GB TC SSF B7-G SSGF1021BG 1334 GB TC SSF B7-G SSGF1026BG 1879 GB C SSF B5-G SSGF1518AG 1141 GB C SSF B5-G SSGF1521AG 1334 GB TC SSF B7-G SSGF1526BG 1879 GB C SSF B5-G SSGF2018AG 1141 GB C SSF B5-G SSGF2021AG 1334 GB TC SSF B7-G SSGF2026BG 1879 GB C SSF B5-G SSGF2518AG 1141 GB C SSF B5-G SSGF2521AG 1334 GB TC SSF B7-G SSGF2526BG 1879 GB C SSF B5-G SSGF3018AG 1141 GB C SSF B5-G SSGF3021AG 1334 GB TC SSF B7-G SSGF3026BG 1879 GB C SSF B5-G SSGF4018AG 1141 GB C SSF B5-G SSGF4021AG 1334 GB TC SSF B7-G SSGF4026BG 1879 GB C SSF B5-G SSGF5018AG 1141 GB C SSF B5-G SSGF5021AG 1334 GB C SSF B5-G SSGF5026AG 1879 GB C SSF B5-G SSGF6018AG 1141 GB C SSF B5-G SSGF6021AG 1334 GB C SSF B5-G SSGF6026AG 1879 GB 65 Ap x Refer to Brochure CA1600 for Dimensions and Engineering Information. See notes on pages 8 and 9, and inside back flap. Vertical motor below gearhead not recommended. Avoiding those positions where the high speed oil seal is immersed in oil, will provide greater security against high speed input seal wear. 278

279 Stainless Steel - Right Angle - Quill Type Hollow Shaft Gearmotors and Speed Reducers 1.75 thru 2.62 CD 56C thru 140TC Applications: Baldor s all stainless speed reducers are easy to clean and sanitize, minimizing bacterial contamination for food processing equipment. Stainless steel provides the high protection for pharmaceutical and chemical processing applications where harsh chemicals and cleaning solutions can be extremely corrosive to aluminum, cast iron and other materials. Soft Starters & Dynamic Brakes Gearmotors and Gear Products SSGHF2026AH Shown Features: Housing and covers are cast stainless steel to endure hostile environments. 304 stainless output shafts and all stainless steel hardware for long rust resistant life. O-ring sealed housing and motor interface helps keeps contaminants out. Pre-filled with food grade (H1) Klubersynth UH synthetic oil. Sealed housing provides maintenance-free lubed for life operation. BISSC certified (Baking Industry Sanitation Standards Committee). Accessories Nominal 1750 In NOTE: Gear Ratio Continuous Duty Output Torque (In-Lbs) Based on Service Class I Torque Ratings (1.0 Service Factor) Service Class II Torque Ratings ( 1.4 Service Factor) Service Class III Torque Ratings ( 2.0 Service Factor) Refer to Brochure CA1600 for Dimensions and Engineering Information. See notes on pages 8 and 9, and inside back flap. Vertical motor below gearhead not recommended. Avoiding those positions where the high speed oil seal is immersed in oil, will provide greater security against high speed input seal wear. Max Input Max Output Torque Rating In-Lbs Mount Style 350 5: C SSHF B5-H SSGHF0518AH 1205 GB : C SSHF B5-H SSGHF1018AH 1205 GB C SSHF B5-H SSGHF1021AH 1396 GB : C SSHF B5-H SSGHF1518AH 1205 GB C SSHF B5-H SSGHF1521AH 1396 GB C SSHF B5-H SSGHF2018AH 1205 GB : C SSHF B5-H SSGHF2021AH 1396 GB C SSHF B5-H SSGHF2026AH 2009 GB C SSHF B5-H SSGHF3018AH 1205 GB : C SSHF B5-H SSGHF3021AH 1396 GB C SSHF B5-H SSGHF3026AH 2009 GB C SSHF B5-H SSGHF4018AH 1205 GB : C SSHF B5-H SSGHF4021AH 1396 GB C SSHF B5-H SSGHF4026AH 2009 GB TC SSHF B7-H SSGHF4026BH 2009 GB : C SSHF B5-H SSGHF5018AH 1205 GB C SSHF B5-H SSGHF5021AH 1396 GB C SSHF B5-H SSGHF6018AH 1205 GB : C SSHF B5-H SSGHF6021AH 1396 GB C SSHF B5-H SSGHF6026AH 2009 GB 60 Ap x Grinders Generators Mod Express Baldor Education Workshops Index Baldor District Offices 279

280 Soft Start & Dynamic Brakes Gearmotors and Gear Products Accessories Grinders Generators Mod Express Baldor Education Workshops Index Baldor District Offices Washdown - Right Angle - Quill Type Solid Shaft WDGF1018AG Shown Nominal 1750 In NOTE: Gear Ratio Continuous Duty Output Torque (In-Lbs) Based on Service Class I Torque Ratings (1.0 Service Factor) Service Class II Torque Ratings ( 1.4 Service Factor) Service Class III Torque Ratings ( 2.0 Service Factor) Gearmotors and Speed Reducers 1.33 thru 3.25 CD 56C thru 140TC Applications: Food processing and other applications regularly exposed to high pressure washdown. Features: Epoxy coated, heavy-duty cast iron housing. Stainless steel output shaft and hardware. Sealed housing, provides maintenance-free, lubed for life operation. Pre-filled with food grade (H1) Klubersynth synthetic oil. Industry standard mounting dimensionally interchangeable with many other worm gear reducers. BISSC certified (Baking Industry Sanitation Standards Committee). Max Input Max Output Torque Rating In-Lbs Mount Style 350 5: C WDF B5-G WDGF0518AG 458 GB C WDF B5-G WDGF1013AG 426 GB C` WDF B5-G WDGF1015AG 450 GB : TC WDF B7-G WDGF1015BG 450 GB C WDF B5-G WDGF1018AG 458 GB C WDF B5-G WDGF1021AG 565 GB TC WDF B7-G WDGF1024BG 661 GB C WDF B5-G WDGF1513AG 426 GB C WDF B5-G WDGF1515AG 450 GB : C WDF B5-G WDGF1518AG 458 GB C WDF B5-G WDGF1521AG 565 GB C WDF B5-G WDGF1524AG 661 GB C WDF B5-G WDGF2013AG 426 GB C WDF B5-G WDGF2015AG 450 GB : C WDF B5-G WDGF2018AG 458 GB TC WDF B7-G WDGF2026BG 755 GB TC WDF B7-G WDGF2032BG 1110 GB C WDF B5-G WDGF3018AG 458 GB C WDF B5-G WDGF3021AG 565 GB : C WDF B5-G WDGF3024AG 661 GB C WDF B5-G WDGF3026AG 755 GB TC WDF B7-G WDGF3032BG 1110 GB C WDF B5-G WDGF4015AG 450 GB C WDF B5-G WDGF4018AG 458 GB : C WDF B5-G WDGF4021AG 565 GB C WDF B5-G WDGF4024AG 661 GB C WDF B5-G WDGF4026AG 755 GB TC WDF B7-G WDGF4032BG 1110 GB C WDF B5-G WDGF5013AG 426 GB C WDF B5-G WDGF5015AG 450 GB : C WDF B5-G WDGF5021AG 565 GB C WDF B5-G WDGF5024AG 661 GB C WDF B5-G WDGF5026AG 755 GB TC WDF B7-G WDGF5032BG 1110 GB C WDF B5-G WDGF6015AG 450 GB C WDF B5-G WDGF6018AG 458 GB : C WDF B5-G WDGF6021AG 565 GB C WDF B5-G WDGF6024AG 661 GB C WDF B5-G WDGF6026AG 755 GB C WDF B5-G WDGF6032AG 1110 GB 87 Ap x See notes on pages 8 and 9, and inside back flap. Vertical motor below gearhead not recommended. Avoiding those positions where the high speed oil seal is immersed in oil, will provide greater security against high speed input seal wear. 280

281 900 Series - Right Angle - Coupling Type - Solid Shaft GLF1018AG Shown Nominal 1750 In Gear Ratio Continuous Duty Output Torque (In-Lbs) Based on Gearmotors and Speed Reducers 1.33 thru 3.75 CD 56C thru 180TC Applications: Ideal for conveyors, material handling, textile machines, packaging machinery. etc. (slow speed and high torque). Features: Heavy duty cast iron housings, chill cast bronze gears, precision ground hardened worm, ball bearings on input shaft, tapered roller bearings on output shaft. Industry-standard mounting dimensions. Pre-filled with food grade (H1) Klubersynth UH synthetic oil, sealed housing provides maintenance-free lubed for life operation. coupling included. Max Input Max Output Torque Rating In-Lbs Mount Style 350 5: C LF B5-G GLF0515AG 380 GB C LF B5-G GLF0821AG 482 GB C LF B5-J GLF0821AJ 482 GB : TC LF B7-G GLF0821BG 482 GB TC LF B7-G GLF0826BG 661 GB TC LF B9-G GLF0826CG 661 GB C LF B5-G GLF1018AG 390 GB C LF B5-G GLF1021AG 482 GB TC LF B7-G GLF1021BG 482 GB TC LF B7-J GLF1021BJ 482 GB 38 10: TC LF B7-G GLF1024BG 566 GB TC LF B7-G GLF1026BG 661 GB TC LF B9-G GLF1026CG 661 GB TC LF B9-G GLF1032CG 965 GB C LF B5-G GLF1513AG 350 GB C LF B5-G GLF1521AG 482 GB C LF B5-J GLF1521AJ 482 GB : TC LF B7-G GLF1526BG 661 GB TC LF B7-J GLF1526BJ 661 GB TC LF B9-G GLF1532CG 965 GB TC LF B9-J GLF1532CJ 965 GB TC LF B9-G GLF1538CG 1178 GB C LF B5-G GLF2013AG 350 GB : C LF B5-G GLF2018AG 390 GB C LF B5-G GLF2021AG 482 GB 38 Ap x Soft Starters & Dynamic Brakes Gearmotors and Gear Products Accessories Grinders Generators Mod Express Baldor Education Workshops NOTE: Service Class I Torque Ratings (1.0 Service Factor) Service Class II Torque Ratings ( 1.4 Service Factor) Service Class III Torque Ratings ( 2.0 Service Factor) Optional Shaft Positions, Base Installation and Mounting available through Mod Express. Refer to a Baldor District Office for pricing and delivery. See notes on pages 8 and 9, and inside back flap. Vertical motor below gearhead not recommended. Avoiding those positions where the high speed oil seal is immersed in oil, will provide greater security against high speed input seal wear. Index Assembly Types Baldor District Offices G H J 281

282 Soft Start & Dynamic Brakes Gearmotors and Gear Products Accessories Grinders Generators Mod Express Baldor Education Workshops Index Baldor District Offices Gearmotors and Speed Reducers 900 Series - Right Angle - Coupling Type - Solid Shaft continued Nominal 1750 In NOTE: Suffix Gear Ratio 88 20: : : : : : C LF B5-J GLF2021AJ 482 GB TC LF B7-G GLF2026BG 661 GB TC LF B7-J GLF2026BJ 661 GB TC LF B9-G GLF2032CG 965 GB C LF B5-G GLF2515AG 380 GB C LF B5-B GLF2518AG 390 GB C LF B5-G GLF2521AG 482 GB C LF B5-J GLF2521AJ 482 GB C LF B5-G GLF2526AG 661 GB TC LF B7-G GLF2526BG 661 GB TC LF B7-J GLF2526BJ 661 GB TC LF B7-G GLF2532BG 965 GB TC LF B9-G GLF2532CG 965 GB TC LF B9-J GLF2532CJ 965 GB C LF B5-G GLF3013AG 350 GB C LF B5-G GLF3015AG 380 GB C LF B5-G GLF3018AG 390 GB C LF B5-J GLF3018AJ 390 GB C LF B5-G GLF3021AG 482 GB C LF B5-G GLF3024AG 566 GB TC LF B7-G GLF3026BG 661 GB TC LF B7-J GLF3026BJ 661 GB TC LF B9-G GLF3032CG 965 GB TC LF B9-G GLF3038CG 1178 GB C LF B5-G GLF4018AG 390 GB C LF B5-G GLF4021AG 482 GB C LF B5-G GLF4024AG 566 GB C LF B5-G GLF4026AG 661 GB TC LF B7-G GLF4032BG 965 GB TC LF B9-G GLF4038CG 1178 GB C LF B5-G GLF5021AG 482 GB C LF B5-G GLF5026AG 661 GB C LF B5-G GLF6015AG 380 GB C LF B5-G GLF6018AG 390 GB C LF B5-G GLF6021AG 482 GB C LF B5-G GLF6026AG 661 GB C LF B5-G GLF6032AG 965 GB TC LF B7-G GLF6032BG 965 GB 100 Service Class I Torque Ratings (1.0 Service Factor) Service Class II Torque Ratings ( 1.4 Service Factor) Service Class III Torque Ratings ( 2.0 Service Factor) G = Left hand output facing input J = Right hand output facing input H = Double Output Shaft Continuous Duty Output Torque (In-Lbs) Based on Vertical motor below gearhead not recommended. Avoiding those positions where the high speed oil seal is immersed in oil, will provide greater security against high speed input seal wear. Max Input Max Output Torque Rating In-Lbs Mount Style Assembly Types Ap x G H J 282

283 900 Series - Right Angle - Solid Shaft GS3018G Shown Nominal 1750 In NOTE: Gear Ratio Continuous Duty Output Torque (In-Lbs) Based on thru 2.62 CD Service Class I Torque Ratings (1.0 Service Factor) Service Class II Torque Ratings ( 1.4 Service Factor) Service Class III Torque Ratings ( 2.0 Service Factor) Gearmotors and Speed Reducers Applications: Ideal for conveyors, material handling, textile machines, packaging machinery and more. Suitable for direct coupling or belted input (slow speed and high torque). Features: Heavy duty cast iron housings, chill cast bronze gears, precision ground hardened worm, ball bearings on input shaft, tapered roller bearings on output shaft. Industry-standard mounting dimensions. Pre-filled with food grade (H1) Klubersynth UH synthetic oil, sealed housing provides maintenance-free lubed for life operation. Optional Shaft Positions and Base Installation available through Mod Express. Refer to a Baldor District Office for pricing and delivery. See notes on pages 8 and 9, and inside back flap. Vertical motor below gearhead not recommended. Avoiding those positions where the high speed oil seal is immersed in oil, will provide greater security against high speed input seal wear. Max Input Max Output Torque Rating In-Lbs Style S G GS1018G 326 GB : S G GS1021G 385 GB S G GS1026G 542 GB S G GS1515G 322 GB : S G GS1518G 326 GB S G GS1521G 385 GB S G GS2015G 322 GB S G GS2018G 326 GB : S G GS2021G 385 GB S G GS2024G 480 GB S G GS2026G 542 GB : S G GS2515G 322 GB S G GS3013G 312 GB S G GS3015G 322 GB : S G GS3018G 326 GB S G GS3021G 385 GB S G GS3026G 542 GB S G GS4015G 322 GB : S G GS4018G 326 GB S G GS4021G 385 GB S G GS4026G 542 GB S G GS5018G 326 GB : S G GS5021G 385 GB S G GS5026G 542 GB S G GS6013G 312 GB S G GS6015G 322 GB : S G GS6018G 326 GB S G GS6021G 385 GB S G GS6024G 480 GB S G GS6026G 542 GB 50 Ap x Soft Starters & Dynamic Brakes Gearmotors and Gear Products Accessories Grinders Generators Mod Express Baldor Education Workshops Index Baldor District Offices 283

284 Soft Start & Dynamic Brakes 1/4 Horsepower Stock Gear- Gearmotors and Speed Reducers Gearmotors and Gear Products Accessories Grinders Generators Mod Express Baldor Education Workshops Index Baldor District Offices 284 Baldor has pre-selected and assembled our stock 900 Series* speed reducers to our most stock popular single-phase, threephase and DC Industrial motors. These pre-assembled Gear- offer a variety of output torques and output speeds to fit most industrial applications. To order select the desired output speed and torque or speed and input horsepower, then choose the corresponding Baldor catalog number. Your Gear- will ship in one package, pre-assembled from the factory within 48 hours. Service Factor Output Torque In. Lbs. Max. Overhung Rating Ratio Input TEFC, 1 Phase 115/230 Volt :1 56C GF0513AGA DS :1 56C GF1013AGA DS :1 56C GF1513AGA DS :1 56C GF2013AGA DS :1 56C GF2513AGA DS :1 56C GF3013AGA DS :1 56C GF4013AGA DS :1 56C GF5015AGA DS :1 56C GF6015AGA DS 45 TEFC, 3 Phase 230/460 Volt :1 56C GF0513AGB DS :1 56C GF1013AGB DS :1 56C GF1513AGB DS :1 56C GF2013AGB DS :1 56C GF2513AGB DS :1 56C GF3013AGB DS :1 56C GF4013AGB DS :1 56C GF5015AGB DS :1 56C GF6015AGB DS 44 TENV, DC SCR, 90 Volts :1 56C GF0513AGC DS :1 56C GF1013AGC DS :1 56C GF1513AGC DS :1 56C GF2013AGC DS :1 56C GF2513AGC DS :1 56C GF3013AGC DS :1 56C GF4013AGC DS :1 56C GF5015AGC DS :1 56C GF6015AGC DS 49 TENV, DC SCR, 180 Volts :1 56C GF0513AGD DS :1 56C GF1013AGD DS :1 56C GF1513AGD DS :1 56C GF2013AGD DS :1 56C GF2513AGD DS :1 56C GF3013AGD DS :1 56C GF4013AGD DS :1 56C GF5015AGD DS :1 56C GF6015AGD DS 49 NOTE: *See pages for 900 Series features. Red catalog number = New item

285 1/3 Horsepower Stock Gear- Gearmotors and Speed Reducers Soft Starters & Dynamic Brakes Baldor has pre-selected and assembled our stock 900 Series* speed reducers to our most stock popular single-phase, threephase and DC Industrial motors. These pre-assembled Gear- offer a variety of output torques and output speeds to fit most industrial applications. To order select the desired output speed and torque or speed and input horsepower, then choose the corresponding Baldor catalog number. Your Gear- will ship in one package, pre-assembled from the factory within 48 hours. Service Factor Output Torque In. Lbs. Max. Overhung Rating Ratio Input TEFC, 1 Phase 115/230 Volt :1 56C GF0513AGA DS :1 56C GF1013AGA DS :1 56C GF1513AGA DS :1 56C GF2013AGA DS :1 56C GF2513AGA DS :1 56C GF3015AGA DS :1 56C GF4018AGA DS :1 56C GF5018AGA DS :1 56C GF6018AGA DS 52 TEFC, 3 Phase, 230/460 Volt :1 56C GF0513AGB DS :1 56C GF1013AGB DS :1 56C GF1513AGB DS :1 56C GF2013AGB DS :1 56C GF2513AGB DS :1 56C GF3015AGB DS :1 56C GF4018AGB DS :1 56C GF5018AGB DS :1 56C GF6018AGB DS 52 TENV, DC SCR, 90 Volt :1 56C GF0513AGC DS :1 56C GF1013AGC DS :1 56C GF1513AGC DS :1 56C GF2013AGC DS :1 56C GF2513AGC DS :1 56C GF3015AGC DS :1 56C GF4018AGC DS :1 56C GF5018AGC DS :1 56C GF6018AGC DS 57 TENV, DC SCR, 180 Volt :1 56C GF0513AGD DS :1 56C GF1013AGD DS :1 56C GF1513AGD DS :1 56C GF2013AGD DS :1 56C GF2513AGD DS :1 56C GF3015AGD DS :1 56C GF4018AGD DS :1 56C GF5018AGD DS :1 56C GF6018AGD DS 57 NOTE: *See pages for 900 Series features. Red catalog number = New item Gearmotors and Gear Products Accessories Grinders Generators Mod Express Baldor Education Workshops Index Baldor District Offices 285

286 Soft Start & Dynamic Brakes 1/2 Horsepower Stock Gear- Gearmotors and Speed Reducers Gearmotors and Gear Products Accessories Grinders Generators Mod Express Baldor Education Workshops Index Baldor District Offices 286 Baldor has pre-selected and assembled our stock 900 Series* speed reducers to our most stock popular single-phase, threephase and DC Industrial motors. These pre-assembled Gear- offer a variety of output torques and output speeds to fit most industrial applications. To order select the desired output speed and torque or speed and input horsepower, then choose the corresponding Baldor catalog number. Your Gear- will ship in one package, pre-assembled from the factory within 48 hours. Service Factor Output Torque In. Lbs. Max. Overhung Rating Ratio Input TEFC, 1 Phase 115/230 Volt :1 56C GF0513AGA DS :1 56C GF1013AGA DS :1 56C GF1515AGA DS :1 56C GF2018AGA DS :1 56C GF2518AGA DS :1 56C GF3018AGA DS :1 56C GF4021AGA DS :1 56C GF5024AGA DS :1 56C GF6024AGA DS 67 TEFC, 3 Phase, 230/460 Volt :1 56C GF0513AGB DS :1 56C GF1013AGB DS :1 56C GF1515AGB DS :1 56C GF2018AGB DS :1 56C GF2518AGB DS :1 56C GF3018AGB DS :1 56C GF4021AGB DS :1 56C GF5024AGB DS :1 56C GF6024AGB DS 63 ENV, DC SCR, 90 Volt :1 56C GF0513AGC DS :1 56C GF1013AGC DS :1 56C GF1515AGC DS :1 56C GF2018AGC DS :1 56C GF2518AGC DS :1 56C GF3018AGC DS :1 56C GF4021AGC DS :1 56C GF5024AGC DS :1 56C GF6024AGC DS 72 TENV, DC SCR, 180 Volt :1 56C GF0513AGD DS :1 56C GF1013AGD DS :1 56C GF1515AGD DS :1 56C GF2018AGD DS :1 56C GF2518AGD DS :1 56C GF3018AGD DS :1 56C GF4021AGD DS :1 56C GF5024AGD DS :1 56C GF6024AGD DS 71 NOTE: *See pages for 900 Series features. Red catalog number = New item

287 3/4 Horsepower Stock Gear- Gearmotors and Speed Reducers Soft Starters & Dynamic Brakes Baldor has pre-selected and assembled our stock 900 Series* speed reducers to our most stock popular single-phase, threephase and DC Industrial motors. These pre-assembled Gear- offer a variety of output torques and output speeds to fit most industrial applications. To order select the desired output speed and torque or speed and input horsepower, then choose the corresponding Baldor catalog number. Your Gear- will ship in one package, pre-assembled from the factory within 48 hours. Service Factor Output Torque In. Lbs. Max. Overhung Rating Ratio Input TEFC, 1 Phase 115/230 Volt :1 56C GF0513AGA DS :1 56C GF1013AGA DS :1 56C GF1518AGA DS :1 56C GF2018AGA DS :1 56C GF2521AGA DS :1 56C GF3021AGA DS :1 56C GF4024AGA DS :1 56C GF5024AGA DS :1 56C GF6026AGA DS 74 TEFC, 3 Phase, 230/460 Volt :1 56C GF0513AGB DS :1 56C GF1013AGB DS :1 56C GF1518AGB DS :1 56C GF2018AGB DS :1 56C GF2521AGB DS :1 56C GF3021AGB DS :1 56C GF4024AGB DS :1 56C GF5024AGB DS :1 56C GF6026AGB DS 65 TENV, DC SCR, 90 Volt :1 56C GF0513AGC DS :1 56C GF1013AGC DS :1 56C GF1518AGC DS :1 56C GF2018AGC DS :1 56C GF2521AGC DS :1 56C GF3021AGC DS :1 56C GF4024AGC DS :1 56C GF5024AGC DS :1 56C GF6026AGC DS 79 TENV, DC SCR, 180 Volt :1 56C GF0513AGD DS :1 56C GF1013AGD DS :1 56C GF1518AGD DS :1 56C GF2018AGD DS :1 56C GF2521AGD DS :1 56C GF3021AGD DS :1 56C GF4024AGD DS :1 56C GF5024AGD DS :1 56C GF6026AGD DS 79 NOTE: *See pages for 900 Series features. Red catalog number = New item Gearmotors and Gear Products Accessories Grinders Generators Mod Express Baldor Education Workshops Index Baldor District Offices 287

288 Soft Start & Dynamic Brakes 1 Horsepower Stock Gear- Gearmotors and Speed Reducers Gearmotors and Gear Products Accessories Grinders Generators Mod Express Baldor Education Workshops Index Baldor District Offices 288 Baldor has pre-selected and assembled our stock 900 Series* speed reducers to our most stock popular single-phase, threephase and DC Industrial motors. These pre-assembled Gear- offer a variety of output torques and output speeds to fit most industrial applications. To order select the desired output speed and torque or speed and input horsepower, then choose the corresponding Baldor catalog number. Your Gear- will ship in one package, pre-assembled from the factory within 48 hours. Service Factor Output Torque In. Lbs. Max. Overhung Rating Ratio Input TEFC, 1 Phase 115/230 Volt :1 56C GF0513AGA DS :1 56C GF1018AGA DS :1 56C GF1521AGA DS :1 56C GF2024AGA DS :1 56C GF2524AGA DS :1 56C GF3024AGA DS :1 56C GF4024AGA DS :1 56C GF5030AGA DS :1 56C GF6030AGA DS 106 TEFC, 3 Phase, 230/460 Volt :1 56C GF0513AGB DS :1 56C GF1018AGB DS :1 56C GF1521AGB DS :1 56C GF2024AGB DS :1 56C GF2524AGB DS :1 56C GF3024AGB DS :1 56C GF4024AGB DS :1 56C GF5030AGB DS :1 56C GF6030AGB DS 98 TENV, DC SCR, 90 Volt :1 56C GF0513AGD DS :1 56C GF1018AGD DS :1 56C GF1521AGD DS :1 56C GF2024AGD DS :1 56C GF2524AGD DS :1 56C GF3024AGD DS :1 56C GF4024AGD DS :1 56C GF5030AGD DS :1 56C GF6030AGD DS 112 TENV, DC SCR, 180 Volt :1 56C GF0513AGC DS :1 56C GF1018AGC DS :1 56C GF1521AGC DS :1 56C GF2024AGC DS :1 56C GF2524AGC DS :1 56C GF3024AGC DS :1 56C GF4024AGC DS :1 56C GF5030AGC DS :1 56C GF6030AGC DS 112 NOTE: *See pages for 900 Series features. Red catalog number = New item

289 1-1/2 Horsepower Stock Gear- Gearmotors and Speed Reducers Gearmotors and Gear Products Soft Starters & Dynamic Brakes Baldor has pre-selected and assembled our stock 900 Series* speed reducers to our most stock popular single-phase, threephase and DC Industrial motors. These pre-assembled Gear- offer a variety of output torques and output speeds to fit most industrial applications. To order select the desired output speed and torque or speed and input horsepower, then choose the corresponding Baldor catalog number. Your Gear- will ship in one package, pre-assembled from the factory within 48 hours. Service Factor Output Torque In. Lbs. Max. Overhung Rating Ratio Input TEFC, 1 Phase 115/230 Volt :1 56C GF0518AGA DS :1 56C GF1018AGA DS :1 56C GF1524AGA DS :1 56C GF2024AGA DS :1 140TC GF2526BGA DS :1 56C GF3030AGA DS :1 56C GF4030AGA DS :1 56C GF5032AGA DS :1 56C GF6038AGA DS 173 TEFC, 3 Phase, 230/460 Volt :1 56C GF0518AGB DS :1 56C GF1018AGB DS :1 56C GF1524AGB DS :1 56C GF2024AGB DS :1 140TC GF2526BGB DS :1 56C GF3030AGB DS :1 56C GF4030AGB DS :1 56C GF5032AGB DS :1 56C GF6038AGB DS 160 TENV, DC SCR, 180 Volt :1 140TC GF0518BGD DS :1 140TC GF1018BGD DS :1 140TC GF1524BGD DS :1 140TC GF2024BGD DS :1 140TC GF2526BGD DS :1 140TC GF3030BGD DS :1 140TC GF4030BGD DS :1 140TC GF5032BGD DS :1 140TC GF6038BGD DS 193 NOTE: *See pages for 900 Series features. Red catalog number = New item Accessories Grinders Generators Mod Express Baldor Education Workshops Index Baldor District Offices 289

290 Soft Start & Dynamic Brakes 2 Horsepower Stock Gear- Gearmotors and Speed Reducers Gearmotors and Gear Products Accessories Grinders Generators Mod Express Baldor Education Workshops Index Baldor District Offices Baldor has pre-selected and assembled our stock 900 Series* speed reducers to our most stock popular single-phase, threephase and DC Industrial motors. These pre-assembled Gear- offer a variety of output torques and output speeds to fit most industrial applications. To order select the desired output speed and torque or speed and input horsepower, then choose the corresponding Baldor catalog number. Your Gear- will ship in one package, pre-assembled from the factory within 48 hours. Service Factor Output Torque In. Lbs. Max. Overhung Rating Ratio Input TEFC, 1 Phase 115/230 Volt :1 140TC GF0521BGA DS :1 140TC GF1024BGA DS :1 140TC GF1526BGA DS :1 140TC GF2026BGA DS :1 140TC GF2530BGA DS :1 140TC GF3030BGA DS :1 140TC GF4032BGA DS :1 140TC GF5038BGA DS :1 140TC GF6038BGA DS 175 TEFC, 3 Phase, 230/460 Volt :1 140TC GF0521BGB DS :1 140TC GF1024BGB DS :1 140TC GF1526BGB DS :1 140TC GF2026BGB DS :1 140TC GF2530BGB DS :1 140TC GF3030BGB DS :1 140TC GF4032BGB DS :1 140TC GF5038BGB DS :1 140TC GF6038BGB DS 168 TENV, DC SCR, 180 Volt :1 140TC GF0521BGD DS :1 140TC GF1024BGD DS :1 140TC GF1526BGD DS :1 140TC GF2026BGD DS :1 140TC GF2530BGD DS :1 140TC GF3030BGD DS :1 140TC GF4032BGD DS :1 140TC GF5038BGD DS :1 140TC GF6038BGD DS 200 NOTE: *See pages for 900 Series features. Red catalog number = New item 290

291 Universal Series - Right Angle - Quill Type - Solid Shaft Nominal 1750 In NOTE: Gear Ratio : : :1 GSF2018AA Shown Continuous Duty Output Torque (In-Lbs) Based on Gearmotors and Speed Reducers 1.33 thru 3.50 CD 56C thru 180TC Applications: Ideal for conveyors, material handling, textile machines, packaging machinery. etc. (slow speed and high torque). Features: Heavy duty cast iron housings, forged bronze worm gears, hardened steel worms, ball bearing on input shaft, tapered roller bearings on output shaft. Integral heavy duty mounting feet cast on top and bottom of housing. Single output shaft, right hand facing input shaft. Pre-lubricated with Mobil SHC634 oil. Max Input Max Output Torque Rating In-Lbs C STF A-A GSF1013AA 411 GB C STF A-A GSF1018AA 450 GB TC STF B-A GSF1018BA 450 GB C STF A-A GSF1020AA 537 GB TC STF B-A GSF1020BA 537 GB TC STF B-A GSF1023BA 610 GB TC STF B-A GSF1026BA 778 GB TC STF C-A GSF1026CA 778 GB TC STF C-A GSF1030CA 889 GB C STF A-A GSF1513AA 411 GB C STF A-A GSF1518AA 450 GB C STF A-A GSF1520AA 537 GB C STF A-A GSF1523AA 610 GB TC STF B-A GSF1523BA 610 GB TC STF B-A GSF1526BA 778 GB TC STF B-A GSF1530BA 889 GB TC STF C-A GSF1530CA 889 GB TC STF C-A GSF1535CA 1220 GB C STF A-A GSF2013AA 411 GB C STF A-A GSF2018AA 450 GB C STF A-A GSF2020AA 537 GB TC STF B-A GSF2020BA 537 GB C STF A-A GSF2023AA 610 GB TC STF B-A GSF2023BA 610 GB C STF A-A GSF2026AA 778 GB TC STF B-A GSF2026BA 778 GB TC STF B-A GSF2030BA 889 GB TC STF C-A GSF2030CA 889 GB TC STF C-A GSF2035CA 1220 GB 90 Service Class I Torque Ratings (1.0 Service Factor) See notes on pages 8 and 9, and inside back flap. Service Class II Torque Ratings ( 1.4 Service Factor) Service Class III Torque Ratings ( 2.0 Service Factor) Mount Style Ap x Soft Starters & Dynamic Brakes Gearmotors and Gear Products Accessories Grinders Generators Mod Express Baldor Education Workshops Index Vertical motor below gearhead not recommended. Avoiding those positions where the high speed oil seal is immersed in oil, will provide greater security against high speed input seal wear. Baldor District Offices 291

292 Soft Start & Dynamic Brakes Gearmotors and Gear Products Accessories Grinders Generators Mod Express Baldor Education Workshops Gearmotors and Speed Reducers Universal Series - Right Angle - Quill Type - Solid Shaft continued Nominal 1750 In NOTE: Gear Ratio 70 25: : : : :1 Continuous Duty Output Torque (In-Lbs) Based on Service Class I Torque Ratings (1.0 Service Factor) Service Class II Torque Ratings ( 1.4 Service Factor) Service Class III Torque Ratings ( 2.0 Service Factor) Max Input Max Output Torque Rating In-Lbs Mount Style C STF A-A GSF2513AA 411 GB C STF A-A GSF2518AA 450 GB C STF A-A GSF2520AA 537 GB C STF A-A GSF2523AA 610 GB TC STF B-A GSF2530BA 889 GB C STF A-A GSF3013AA 411 GB C STF A-A GSF3018AA 450 GB C STF A-A GSF3020AA 537 GB C STF A-A GSF3023AA 610 GB C STF A-A GSF3026AA 778 GB TC STF B-A GSF3030BA 889 GB TC STF B-A GSF3035BA 1220 GB C STF A-A GSF4013AA 411 GB C STF A-A GSF4018AA 450 GB C STF A-A GSF4020AA 537 GB C STF A-A GSF4023AA 610 GB C STF A-A GSF4026AA 778 GB C STF A-A GSF4030AA 889 GB TC STF B-A GSF4030BA 889 GB TC STF B-A GSF4035BA 1220 GB C STF A-A GSF5013AA 411 GB C STF A-A GSF5018AA 450 GB C STF A-A GSF5020AA 537 GB C STF A-A GSF5023AA 610 GB C STF A-A GSF5026AA 778 GB C STF A-A GSF5030AA 889 GB TC STF B-A GSF5030BA 889 GB TC STF B-A GSF5035BA 1220 GB C STF A-A GSF6018AA 450 GB C STF A-A GSF6020AA 537 GB C STF A-A GSF6023AA 610 GB C STF A-A GSF6026AA 778 GB C STF A-A GSF6030AA 889 GB TC STF B-A GSF6035BA 1220 GB 83 Ap x Optional Shaft Positions, Bases Installation and Mounting available through Mod Express. Refer to Baldor District Office for and Delivery. See notes on pages 8 and 9, and inside back flap. Index Baldor District Offices Vertical motor below gearhead not recommended. Avoiding those positions where the high speed oil seal is immersed in oil, will provide greater security against high speed input seal wear. 292

293 1000 Series - Inline - Quill Type Solid Shaft Gearmotors and Speed Reducers 4 Sizes 56C thru 210TC Applications: Ideal for conveyors, material handling, textile machines, packaging machinery. etc. (slow speed and high torque). Features: Dimensionally interchangeable with major European equivalents. Rugged cast iron construction with precision machined and heat treated alloy steel gears for high efficiency and quiet operation. Pre-lubricated with Mobil SHC634 oil. Soft Starters & Dynamic Brakes Gearmotors and Gear Products Nominal 1750 In 194 NOTE: Gear Ratio 9: : : : : :1 GIF0932A Shown Continuous Duty Output Torque (In-Lbs) Based on Max Input Max Output Torque Rating In-Lbs C F S-B5 GIF0932A 576 GB TC F S-B7 GIF0932B 576 GB TC F S-B7 GIF0942B 658 GB TC F S-B9 GIF0942C 658 GB TC F S-B9 GIF0962C 962 GB TC F S-B11 GIF0962D 962 GB TC F S-B11 GIF0972D 1565 GB C F S-B5 GIF1432A 576 GB TC F S-B7 GIF1442B 658 GB TC F S-B9 GIF1462C 962 GB TC F S-B9 GIF1472C 1565 GB TC F S-B11 GIF1472D 1565 GB C F S-B5 GIF1832A 576 GB C F S-B5 GIF1842A 658 GB TC F S-B7 GIF1842B 658 GB TC F S-B7 GIF1862B 962 GB TC F S-B9 GIF1862C 962 GB TC F S-B9 GIF1872C 1565 GB TC F S-B11 GIF1872D 1565 GB C F S-B5 GIF2532A 576 GB C F S-B5 GIF2542A 658 GB TC F S-B7 GIF2542B 658 GB TC F S-B7 GIF2562B 962 GB TC F S-B9 GIF2562C 962 GB TC F S-B9 GIF2572C 1565 GB C F S-B5 GIF4042A 658 GB C F S-B5 GIF4062A 962 GB TC F S-B7 GIF4062B 962 GB C F S-B5 GIF5642A 658 GB C F S-B5 GIF5662A 962 GB 48 Service Class I Torque Ratings (1.0 Service Factor) Service Class II Torque Ratings ( 1.4 Service Factor) Service Class III Torque Ratings ( 2.0 Service Factor) Mount Style Ap x Accessories Grinders Generators Mod Express Baldor Education Workshops Index Baldor District Offices 293

294 Soft Start & Dynamic Brakes Gearmotors and Gear Products 1000 Series - Right Angle - Quill Type Hollow Bore Gearmotors and Speed Reducers 4 Sizes 56C thru 210TC Applications: Ideal for conveyors, material handling, textile machines, packaging machinery. etc. (slow speed and high torque). Features: Dimensionally interchangeable with major European equivalents. Rugged cast iron construction. Helical and worm gear combinations afford optimum performance.* Pre-lubricated with Mobil SHC634 oil. Accessories Grinders Generators Mod Express Baldor Education Workshops Index Baldor District Offices Nominal 1750 In NOTE: Gear Ratio : : : : :1 Continuous Duty Output Torque (In-Lbs) Based on Service Class I Torque Ratings (1.0 Service Factor) Service Class II Torque Ratings ( 1.4 Service Factor) Service Class III Torque Ratings ( 2.0 Service Factor) * See page 299 for base, flange and shaft kits. Vertical motor below gearhead not recommended. Avoiding those positions where the high speed oil seal is immersed in oil, will provide greater security against high speed input seal wear. Max Input Max Output Torque Rating In-Lbs Mount Style C F1032R-14S-B5 GRF1432A 831 GB TC F1032R-14S-B7 GRF1432B 831 GB C F1042R-14S-B5 GRF1442B 1077 GB TC F1042R-14S-B9 GRF1442C 1077 GB TC F1052R-14S-B7 GRF1452B 1201 GB TC F1052R-14S-B9 GRF1452C 1201 GB TC F1062R-14S-B9 GRF1462C 1582 GB TC F1062R-14S-B11 GRF1462D 1582 GB C F1032R-22S-B5 GRF2232A 831 GB C F1042R-22S-B5 GRF2242A 1077 GB TC F1042R-22S-B7 GRF2242B 1077 GB TC F1052R-22S-B7 GRF2252B 1201 GB TC F1052R-22S-B9 GRF2252C 1201 GB TC F1062R-22S-B9 GRF2262C 1582 GB C F1032R-32S-B5 GRF3232A 831 GB TC F1042R-32S-B7 GRF3242B 1077 GB TC F1052R-32S-B7 GRF3252B 1201 GB TC F1052R-32S-B9 GRF3252C 1201 GB TC F1062R-32S-B7 GRF3262B 1582 GB TC F1062R-32S-B9 GRF3262C 1582 GB C F1032R-63S-B5 GRF6332A 831 GB C F1042R-63S-B5 GRF6342A 1077 GB C F1052R-63S-B5 GRF6352A 1201 GB TC F1052R-63S-B7 GRF6352B 1201 GB TC F1062R-63S-B9 GRF6362C 1582 GB C F1032R-100S-B5 GRF10032A 831 GB C F1042R-100S-B5 GRF10042A 1077 GB TC F1052R-100S-B7 GRF10052B 1201 GB TC F1062R-100S-B7 GRF10062B 1582 GB 80 Output Bore Sizes GRF1442C Shown Ap x F1032R F1042R F1052R F1062R

295 Ratio Multiplier - Inline - Quill Type Solid Shaft Gearmotors and Speed Reducers 2 Sizes 56C thru 140TC Applications: Reducer or Increaser. Combine with Right Angle units for high ratios. May also be used as a stand alone with optional base kits. Features: High efficiency. Cast iron construction, universal mounting positions, and optional base mounting. Internal compression chamber eliminates breather vent. Lubricated for life with Mobil SHC634 oil. Soft Starters & Dynamic Brakes Gearmotors and Gear Products Size 1750 in. Gear Ratio Input Style Ratings at 1750 Input Output Style Type :1 56C 56C GCF2X01AA 311 GB FX1-2-B5-56C :1 56C 56C GCF3X01AA 311 GB FX1-3-B5-56C :1 56C 56C GCF4X01AA 311 GB FX1-4-B5-56C :1 56C 56C GCF5X01AA 311 GB FX1-5-B5-56C :1 140TC 140TC GCF2X02BB 375 GB FX2-2-B7-140TC :1 140TC 140TC GCF3X02BB 375 GB FX2-3-B7-140TC :1 140TC 140TC GCF4X02BB 375 GB FX2-4-B7-140TC :1 56C 140TC GCF5X02AB 375 GB FX2-5-B5-140TC :1 140TC 140TC GCF5X02BB 375 GB FX2-5-B7-140TC 22 Size Ratio Output Input Output Output Torque Output Shaft OHL 1 2: : : : : : : : Accessories Grinders Generators Mod Express Baldor Education Workshops BRMX01 with Style SX1 Ratio Multiplier Optional Base Kit Size 1 BRMX01 37 A8 2 BRMX02 66 A8 Index Baldor District Offices Ratio Multiplier with F900 Series Reducer 295

296 Soft Start & Dynamic Brakes Gearmotors and Gear Products Accessories Grinders Generators Mod Express Baldor Education Workshops Index Baldor District Offices 900 Series - Right Angle Base Kits Horizontal Base J Base Vertical Base Washdown Base Universal Series - Right Angle Base Kits Base Description Size (Position) Gearmotors and Speed Reducers HORIZ. 913 (A,B) B13H71 37 A8 3 VERT. low 913 (D,F) B13V81 66 A8 2 VERT. high 913 (C,E) B13V91 67 A8 3 VERT J 913 (X,Y) B13J92 65 A8 3 HORIZ. 915 (A,B) B15H71 26 A8 4 VERT. low 915(D,F) B18V81 68 A8 3 VERT. high 915 (C,E) B18V91 69 A8 3 VERT. J 915 (X,Y) B18J92 67 A8 6 HORIZ. 918 (A,B) B18H71 44 A8 6 VERT. low 918 (D,F) B18V81 68 A8 3 VERT. high 918 (C,E) B18V91 69 A8 3 VERT. J 918 (X,Y) B18J92 67 A8 6 HORIZ. 921G (A,B) B21GH71 46 A8 5 HORIZ. 921 (A,B) B21H71 49 A8 6 VERT. low 921 (D,F) B21V81 74 A8 4 VERT. high 921 (C,E) B21V91 76 A8 6 VERT. J 921 (X,Y) B21J92 74 A8 7 HORIZ. 924 (A,B) B24H71 58 A8 8 VERT. low 924 (D,F) B24V81 85 A8 4 VERT. high 924 (C,E) B24V91 90 A8 6 VERT. J 924 (X,Y) B24J92 85 A8 9 HORIZ. 926 (A,B) B26H71 66 A8 9 VERT. low 926 (D,F) B26V A8 6 VERT. high 926 (C,E) B26V A8 9 VERT. J 926 (X,Y) B26J A8 10 HORIZ. 930 (A,B) B30H71 75 A8 4 HORIZ. 932 (A,B) B32H71 89 A8 13 VERT. low 932 (D,F) B32V A8 10 VERT. high 932 (C,E) B32V A8 13 HORIZ. 938 (A,B) B38H A8 15 VERT. low 938(D,F) B38V A8 38 VERT. high 938(C,E) B38V A8 36 Optional Washdown Base Kits HORIZ. 913 (A,B) WDB13H71 49 A8 3 HORIZ. 915 (A,B) WDB15H71 49 A8 4 HORIZ. 918 (A,B) WDB18H71 60 A8 6 HORIZ. 921 (A,B) WDB21H71 64 A8 6 HORIZ. 924 (A,B) WDB24H71 70 A8 8 HORIZ. 926 (A,B) WDB26H71 79 A8 9 HORIZ. 930 (A,B) WDB30H71 87 A8 6 HORIZ. 932 (A,B) WDB32H A8 13 Kit includes angle bases and hardware. Converts style STF to SVF. Size Flange Wgt C/140TC B1317V81 67 A C/140TC B2022V81 70 A C/140TC B2530V A TC B2530V A C/140TC 180TC/210TC B3500V A

297 C-Face Flange Kits (coupling type) Gearmotors and Speed Reducers Flange adapts C face motors to 900 Series type S reducers. Includes flange, flexible coupling and mounting hardware. Size Flange Wgt C SFL913B5 103 A C SFL918B5 103 A TC SFL918B7 103 A C SFL918B5 103 A TC SFL918B7 103 A C SFL921B5 116 A TC SFL921B7 116 A C SFL924B5 116 A TC SFL924B7 116 A C SFL926B5 149 A TC SFL926B7 149 A8 15 Soft Starters & Dynamic Brakes Gearmotors and Gear Products Accessories Riser Block Kits Riser Blocks permit the gearbox to be mounted in the most desirable position (high speed input shaft above the oil level). They mount on top of the gearbox to provide clearance between the motor and the mounting surface. Kit includes the Riser Block and attachment bolts. Size Flange Wgt C RBK13B5 38 A C/140TC RBK15B5 49 A C/140TC RBK18B5 60 A C/140TC RBK21B5 79 A C/140TC RBK24B5 83 A TC RBK24B9 158 A C/140TC RBK26B5 87 A TC RBK26B9 192 A C/140TC RBK30B5 100 A TC RBK30B9 214 A C/140TC RBK32B5 133 A TC RBK32B9 265 A8 15 Grinders Generators Mod Express Baldor Education Workshops Torque Arm Kits Kit includes turnbuckle and both mounting brackets. Secures hollow shaft reducer to application Size 913 TA13HK 97 A TA18HK 107 A TA21HK 119 A TA24HK 120 A TA26HK 123 A TA30HK 125 A TA32HK 128 A TA38HK 133 A8 2 Index Baldor District Offices 297

298 Soft Start & Dynamic Brakes Gearmotors and Gear Products Accessories Grinders Generators Mod Express Baldor Education Workshops Index Baldor District Offices Output Flange Kits Size Bushing Kits for Hollow Shaft Reducers Size /926 Double Reduction Adapter Kit Bushing Kit Gearmotors and Speed Reducers 913 FL13HK 62 A FL15HK 67 A FL18HK 70 A FL21HK 78 A FL24HK 112 A FL26HK 120 A FL30HK 125 A FL32HK 130 A FL38HK 134 A8 12 Shaft Shaft Size Diameter Diameter 3/4 BU100H A8 1-1/4 BU107H A8 924/926 7/8 BU100H A8 1-5/16 BU107H A8 15/16 BU100H A BU115H A8 15/16 BU107H A8 1-7/16 BU115H A8 1 BU107H A8 1-1/2 BU115H A8 930/ /8 BU107H A8 1-5/8 BU115H A8 1-3/16 BU107H A8 1-11/16 BU115H A8 1-3/4 BU115H A8 900 series double reduction units may be assembled from stock single reduction units using the adapter kits. Primary(1) Unit Secondary(2) Unit DR913X913B B5 103 A8 DR913X918B B5 109 A8 DR913X921B B5 115 A8 DR913X924B B5 115 A8 DR913X926B B5 125 A8 DR918X924B B7 125 A8 DR918X926B B7 130 A8 DR918X932B B7 130 A8 DR924X938B B9 130 A8 NOTE: Each adapter kit consists of: 1 Adapter; 1 Seal (Installed); 1 Shim Set; 4 Screws; 1 Bearing Cup (Installed); 4 Lock Washers; and 1 Sealant Package. (1) Any style except shaft mount (2) F and HF styles only Reduces bore size of Quill type input shafts from 7/8 to 5/8. Sintered metal bushing with integral internal and external keys FBA 38 A8 298

299 1000 Series Output Flange Kits Size 1032R 1033R 1042R 1043R 1052R 1053R 1062R 1063R Gearmotors and Speed Reducers FL1030VK 99 A8 3 FL1040VK 110 A8 3 FL1050VK 131 A8 4 FL1060VK 153 A8 6 Soft Starters & Dynamic Brakes Gearmotors and Gear Products 1000 Series Torque Arm Kits Size 1032R 1033R 1042R 1043R 1052R 1053R 1062R 1063R TA1030VK 99 A8 2 TA1040VK 110 A8 3 TA1050VK 131 A8 3 TA1060VK 153 A8 7 Accessories Grinders Generators 1000 Series Modular Base Kits Size 1032R 1033R 1042R 1043R 1052R 1053R 1062R 1063R B1030H71 37 A8 1 B1040H71 55 A8 2 B1050H71 75 A8 1 B1060H71 91 A8 5 Mod Express Baldor Education Workshops 1000 Series Output Shaft Kits Size 1032R 1033R 1042R 1043R 1052R 1053R 1062R 1063R Single Projection Double Projection SH1030S 67 SH1030D 80 A8 2 SH1040S 73 SH1040D 99 A8 2 SH1050S 78 SH1050D 107 A8 3 SH1060S 100 SH1060D 125 A8 3 Index Baldor District Offices 299

300 Soft Start & Dynamic Brakes Gearmotors and Gear Products ized Speed Reducer Selection 1. Determine service class from table below. 2. Select a reducer size that satisfies output, service class and/or output torque requirements. 3. Check overhung load capacity 4. Select appropriate motor from C-Face sections in this catalog. Service Factor Table Gearmotors and Speed Reducers Overhung Overhung load is the radial load imposed on a shaft by a sprocket, pinion, pulley or sheave which tends to bend the shaft. When a sprocket, pinion, pulley or sheave is mounted on the reducer output shaft, a calculation should be made to determine whether the resultant overhung load exceeds the rated overhung load capacity of the reducer, using the following formula: OHL = x x K or; OHL = T x K N x R R Accessories Grinders Generators Mod Express Baldor Education Workshops Index Baldor District Offices AGMA Class of Service Service Factor Maximum Input Speeds 900 Series Single Reduction Overhung Ratings Operating Conditions I 1.00 Moderate Shock - not more than 15 minutes in 2 hours. Uniform - not more than 10 hours per day. II 1.25 Moderate Shock - not more than 10 hours per day Uniform - more than 10 hours per day. II 1.50 Heavy Shock - not more than 15 minutes in 2 hours. Moderate Shock - more than 10 hours per day. III 1.75 Heavy Shock - not more than 10 hours per day Heavy Shock - more than 10 hours per day. 900 Series Size Universal Size Max. Input Gear Size Center Distance Inches Universal Series Single Reduction Overhung Ratings Overhung Rating Lbs. (At Center of Keyway) Gear Size Center Distance Inches Overhung Rating Lbs. (At Center of Keyway) Wherein, OHL = Overhung load in pounds T = Torque transmitted by the shaft N = of shaft R = Pitch radius of sprocket, sheave, etc. K = Factor from overhung load factor table. SPROCKET 1.00 GEAR 1.25 V-BELT 1.50 FLAT BELT 2.50 Overhung Factor (K) If the calculated overhung load exceeds the overhung load rating of the reducer, consideration should be given to: A) Increase sprocket, sheave etc. radius B) Use outboard bearing on shaft C) Use larger reducer The minimum radius allowable for a given drive may be determined by using: Minimum Radius = T x K OHL Capacity of Reducer 300

301 AC C-Face Kits for Field Conversion Accessories Features: Complete kits with all hardware necessary for converting Baldor 56 through 445T frame rigid base motors to C-Face mounting with base. For a Baldor conversion, refer to the Mod Express Section in this catalog. Please furnish the motor specification number when ordering. Soft Starters & Dynamic Brakes Gearmotors and Gear Products Kit Description Type/ Bearing Enclosure T 34/48C 6203 TEFC 33 A /56C 6203 TEFC 33 A A 34/143-5TC 6205 ODP 36 A T 34/143-5TC 6205 TEFC 36 A /56C,143-5TC 6205 TEFC 39 A /56C,143-5TC 6205 ODP 39 A /56C,143-5TC 6205 TEFC 56 A /182-4TC 6206 TEFC 61 A /182-4TC 6206 ODP 53 A /182-4C 6206 TEFC 61 A A 36/213-5TC 6207 OPSB 94 A B 36/213-5TC 6207 ODP 94 A /182-4C 6206 ODP 77 A /182-4TC 6206 TEFC 46 A /182-4TC 6206 ODP 45 A /182-4TC 6206 TEFC 61 A /213-5C, TC 6307 ODP 88 A /213-5C, TC 6307 TEFC 95 A /254-6UC, TC 6309 ODP 103 A /254-6UC, TC 6309 TEFC 100 A /254-6UC, TC 6309 TEFC 139 A /284-6UC, TC 6311 TEFC 182 A /254-6UC, TC 6309 ODP 146 A /284-6UC, TC 6311 ODP 182 A /324-6UC, TC 6312 TEFC 209 A /284-6UC, TC 6311 TEFC 198 A /284-6UC, TC 6311 ODP 192 A /324-6 UC, TC 6312 ODP 238 A /324-6UC, TC 6312 TEFC 267 A /324-6UC, TC 6312 ODP 432 A /364-5 UC & TC 6313 ODP 421 A /404-5TC 6316 TEFC 576 A /364-5UC, TC 6313 TEFC 421 A /364-5UC, TC 6313 ODP 421 A /404-5UC, TC 6316 TEFC 576 A /404-5UC, TC 6316 ODP 576 A /444-7UC, TSC 6313 ODP 631 A /444-7UC, TC 6319 ODP 631 A /444-9UC, TC 6319 TEFC 677 A /404-5 UC & TC 6316 ODP 487 A /404-5 UC & TSC 6313 ODP 487 A A 44/404 USC, TSC 6312 OPEN 487 A8 40 NOTE: BA Dimension will be non-standard after conversion on 143-5T, SHADED RATINGS ARE CAST IRON FRAMES 182-4T, 213-5T and 254-6T. Specification number of motor should be verified when ordering. = Suitable only for field conversion of motors manufactured with external rabbets on the stator housings. = Contact a District Office with nameplate specification number to determine correct kit. Accessories Grinders Generators Mod Express Baldor Education Workshops Index Baldor District Offices 301

302 Soft Start & Dynamic Brakes Gearmotors and Gear Products DC C-Face Kit for Field Conversion Features: For DC motors with catalog number ending in P. Complete kits for motors on pages Accessories Accessories Grinders Generators Mod Express Baldor Education Workshops Index Baldor District Offices 302 Kit Bearing Enclosure Double C-Face Brake Kits NOTE: See notes on page 8 and inside back flap. D-Flange Kits Coil Voltage: 115/ Enclosure Part Features: Double C-Face coupler brakes. Mounts on motors with C-Face, provides C-face mounting on brake. Spring set, electrically released. Complete kits with hardware necessary for converting Baldor 145T-445T frame rigid base motors to D-Flange mounting with base. Please furnish the motor specification number when ordering. Shipping Weight Lbs T TEFC 35EP1506A01SP 241 A T OPEN 35EP1604A01SP 256 A T OPEN 36EP1405A09SP 261 A TD TEFC 36EP1304A62SP 133 A U,T TEFC 10EP1502A01SP 573 A U,T TEFC 12EP1501A03SP 639 A U,T OPEN 14EP1601A01SP 822 A U,T TEFC 14EP1705A01SP 822 A U,T OPEN 16EP1601A01SP 1022 A U,T TEFC 16EP1501A01SP 868 A U,T OPEN 18EP1600A01SP 1455 A U,T TEFC 18EP1500A01SP 1455 A8 168 Ap x ATC 6206 Drip-Proof 521 A ATC 6207 Drip Proof or Totally Enclosed 625 A ATC 6209 Drip Proof of Totally Enclosed 965 A ATC 6210 Drip Proof 1279 A ATC 6211 Drip Proof 1783 A ATC 6213 Drip Proof or Totally Enclosed 2736 A ATC 6214 Drip Proof or Totally Enclosed 3314 A8 179 Brake Rating Brake Mounting 3 ft-lb 56C CBK A ft-lb 56C CBK A ft-lb 145TC CBK A ft-lb 145TC CBK A ft-lb 145TC CBK A8 12

303 Drip Covers for Field Conversion Standard ODP to Vertical Mount Accessories Features: Complete kits with all hardware, attaches to endplate with no drilling. Designed to protect open steel band motors from rain, snow and ice when mounted outdoors in a vertical position. Made from heavy steel. Primed and painted inside and out. For a Baldor conversion, refer to the Mod Express Section in this catalog. Soft Starters & Dynamic Brakes Gearmotors and Gear Products Kit Description FCD34 34/ A8 1 FCD35 35/ A8 1 FCD36 36/ A8 2 FCD37 37/ A8 3 FCD39 39/ A8 3 FCD40 40/ A8 12 FCD42 42/ A8 5 NOTE: Refer to Abbreviations on the inside back flap for definitions of Kit No. and Description. Fan Cover/Conduit Boxes for Field Conversion Kit Standard TEFC Cast Iron Applications: For all Cast Iron construction. NOTE: Refer to Abbreviations on the inside back flap for definitions of Kit No. and Description. numbers ending in WB include a cast iron conduit box and lid. NOT FOR USE ON EXPLOSION PROOF MOTORS. Ball Bearing to Roller Bearing Conversion Description Features: Complete kits consists of cast iron fan covers and cast iron conduit boxes when necessary. The kits also include all necessary mounting hardware. These kits replace the standard steel fan cover and aluminum conduit box when used. For a Baldor conversion, refer to the Mod Express Section in this catalog. TEFC 449T thru 5011L Applications: To accommodate belted loads. FFC05 05/143-5T 106 A8 6 FFC06 06/182-4T 114 A8 10 FFC07WB 07/213-5T 169 A8 19 FFC09WB 09/254-6U & T 233 A8 28 SHADED RATINGS ARE CAST IRON FRAMES Features: Complete kit consists of roller bearing retainer, spacers, and proper grease. For Baldor conversion, refer to the Mod Express section in this catalog. Accessories Grinders Generators Mod Express Baldor Education Workshops Index Baldor District Offices Poles Enclosure 449T 4,6,8 TEFC RBT A L 4 TEFC RBT A L 6 TEFC RBT A8 34 NOTE: All motors 449T through 5011L are stocked with ball bearings suitable for coupled loads. If load is belted, a roller bearing may be required. Contact your local Baldor office. 303

304 Soft Start & Dynamic Brakes Gear Accessories Conduit Box Kit Accessories Baldor 24 stock gearmotors are designed to accommodate this optional conduit/capacitor box. Gearmotors and Gear Products Types Kit Description Accessories 2412, 2416, 2420, 2424 Combination Conduit/Capacitor Mounting Box Kit BKP A8 1 Grinders Generators Mod Express Baldor Education Workshops Index Baldor District Offices PSM Mounting Adapters L Type Mounting Brackets and Gearmotors UL, cul and CSA Approvals Product Type CSA LR2262 B92 is formed steel mounting base that bolts to machined surface on bottom of PSM gear box casting. Provides secure foot mounting of gear motor and drop-in interchangeability with other major manufacturers. B93 is a three point face mounting adapter. Provides interchangeability with other manufacturers. Description Applications: Mounting bracket for PSSH and PSL gear motors. Securely mounts to gear face in 90 degree locations for floor, wall or ceiling mount. LB74 is not recommended for PSL/PSLH units weighing over 20 lbs. For units weighing more than 20 lbs. use LB75. NOTE: (1) Painted Baldor gray. LB73 & LB73GR for PSSH style gearmotors, LB74 & LB75 for PSL/PSLH style gearmotors. B92 Foot Mount 27 A8 1 B93 3 Point Face Mount 34 A8 1 Wgt LB73 27 A8 2 LB73GR 27 A8 10 LB74 38 A8 2 LB75 54 A8 1 UL E46145 AC Models and s 24, 25, 33 Models and s 24, 25, 33 DC Models and s 73, 74: 90V Ratings Only Models and s 25, 33: Not Restricted to 90 Volts Models and s 23, 25, 33, 73, 74, 125, 135 CUL E46145 Model and s 23, 125, 135 NOTE: See notes on pages 8 and 9, and inside back flap. 304

305 Adjustable Bases Accessories These motor bases simplify mounting and belt tension adjustment at installation and during later maintenance checks. These are heavy duty adjustable motor bases manufactured of steel or plate. All bases are detergent washed, painted with dark gray primer and oven baked for corrosion resistance. The nuts and bolts are zinc plated. 215T and smaller bases feature one adjusting screw. Bases for 254T frame and larger motors feature two adjusting screws. mounting bolts are included. Bases listed can be used with motor frame numbers given and succeeded by the letters S, T, U, US and TS, or any other letter combinations provided the motors base meets standards. Freight is prepaid when included with motors totaling 1000 pounds per shipment. Base No. of Adjusting Screws NOTE: Bases not suitable for vertical mounting. See base dimensions on next page. (1) One adjustable motor rail. Mounting Bolt Size Ap x 48 B48T 59 A8 1 5/16 x B56T 59 A8 1 5/16 x T B143T 77 A8 1 5/16 x T B145T 77 A8 1 5/16 x T B182T 82 A8 1 3/8 x 1 1/ T B184T 82 A8 1 3/8 x 1 1/ T B213T 95 A8 1 3/8 x 1 1/ T B215T 95 A8 1 3/8 x 1 1/ T B254T 158 A8 2 1/2 x 1 3/ T B256T 158 A8 2 1/2 x 1 3/ T B284T 180 A8 2 1/2 x T B286T 180 A8 2 1/2 x T B324T 279 A8 2 5/8 x 2 1/ T B326T 279 A8 2 5/8 x 2 1/ T B364T 348 A8 2 5/8 x 2 1/ T B365T 348 A8 2 5/8 x 2 1/ T B404T 518 A8 2 3/4 x T B405T 518 A8 2 3/4 x T B444T 634 A8 2 3/4 x T B445T 634 A8 2 3/4 x T B447T 747 A8 2 3/4 x 3 1/ T B449T 747 A8 2 3/4 x 3 1/ B5000RLS (1) 1127 A8 2 7/8 x 3 1/2 149 Soft Starters & Dynamic Brakes Gearmotors and Gear Products Accessories Grinders Generators Mod Express Baldor Education Workshops Baldor District Offices Index 305

306 Soft Start & Dynamic Brakes Adjustable Bases Dimension Diagrams Accessories Gearmotors and Gear Products Accessories Grinders Generators Mod Express Baldor Education Workshops E F AL AM AO AR AT AU AX BB BT XC D Bolt AY Bolt B48T B56T B143T B145T 2.75 B182T B184T 3.75 B213T B215T B254T B256T B284T B286T B324T B326T B364T B365T 7.00 B404T B405T 8.00 B444T B445T 9.00 B447T B449T /16 x 1 3/8 x /16 x 1 3/8 x /8 x 1-3/4 1/2x /8 x 1-3/4 1/2 x /2 x 1-3/4 5/8 x /2 x 2 5/8 x /8 x 2-1/2 3/4 x /8 x 2-1/2 3/4 x /4 x 3 3/4 x /4 x 3 3/4 x /4 x 3-1/2 3/4 x 14 3/4 x 11 Index Baldor District Offices E AL AO AL AU AX AZ BT XC XO XE D Bolt AY Bolt 500 B5000RLS /8 x 3-1/2 7/8 x 16 DIMENSIONS ARE FOR REFERENCE ONLY, CONSULT A BALDOR DISTRICT OFFICE FOR CERTIFIED DIMENSIONS 306

307 Conversion Bases Accessories These Conversion Bases are designed to allow T frame motors to be used where corresponding U frame motors have been applied. Consisting of right and left hand pieces that fit to existing mounting studs positioned for U frame motors. The T frame motor is mounted to the pieces resulting in compensation for the difference in motor height, shaft position and mounting hole between the previous U frame motor and the replacement T frame motor. Made of the same top quality material as the adjustable motor bases. The same freight allowance applies. Soft Starters & Dynamic Brakes Gearmotors and Gear Products Converts From U Converts To T NOTE: Dimensions are for one piece. Two pieces supplied. Design is for horizontal mounting. shimming may be required for direct drive applications. Ap x Height Inches Width Inches Length Inches Thread CB1814T 182/ T/145T 65 A /4 7 1/2 5/16-18 CB2118T 213/ T/184T 92 A8 2 3/4 1 3/4 9 1/2 3/8-16 CB2521T 254U/256U 213T/215T 106 A / /4 3/8-16 CB2825T 284U/286U 254T/256T 144 A8 7 3/4 2 3/4 14 1/4 1/2-13 CB3228T 324U/326U 284T/286T 199 A /4 15 3/4 1/2-13 CB3632T 364U/365U 324T/326T 245 A / /2 5/8-11 CB4036T 404U/405U 364T/365T 337 A /4 18 5/8 5/8-11 Accessories Grinders Generators Metric Weld On Bases Heavy duty, stamped steel metric bases for welding to steel band motor designs. These give metric base mounting dimensions to frame motors. Mod Express Baldor Education Workshops IEC NOTE: See base dimensions on next page. Description Ap x Index Baldor District Offices D71 MB /42 20 A8 1 D80 MB / A8 1 D90 MB / A8 2 D112 MB / A8 3 D132 MB / A

308 Soft Start & Dynamic Brakes Conversion Bases Dimension Diagrams Accessories Gearmotors and Gear Products Accessories Grinders Generators Mod Express Baldor Education Workshops Converts From Converts To A B Height C D E F G H J K L M N(Thread) CB1814T T-145T /16-18 CB2118T T-184T /8-16 CB2521T 254U-256U 213T-215T /8-16 CB2825T 284U-286U 254T-256T /2-13 CB3228T 324U-326U 284T-286T /2-13 CB3632T 364U-365U 324T-326T /8-11 CB4036T 404U-405U 364T-365T /8-11 Metric Weld On Bases Dimension Diagrams Index Baldor District Offices IEC E AL AM AR D D D90S D90L D112S D112M D132S D132M DIMENSIONS ARE FOR REFERENCE ONLY, CONSULT A BALDOR DISTRICT OFFICE FOR CERTIFIED DIMENSIONS 308

309 Automatic Greaser Accessories Applications: Provide automatic regreasing to larger AC or DC motors with grease passages on endplates Soft Starters & Dynamic Brakes Features: Replaceable cartridge with Exxon Polyrex EM grease, microprocessor control of 250cc grease dispenser over (half, 1, 2, 3, 6 and 12 months). Anti-vibration design, high operating pressure for contamination removal. 3/8 NPT thread on output for adaptation by installer or using RIK250 installation kit. Usual installation is one greaser on each endplate. Gearmotors and Gear Products Grinders Baldor District Offices Generators Index Baldor Education Workshops Mod Express Accessories Description AGD250 Automatic grease dispenser (250cc without grease and battery) 369 A8 4 AGD250-R Service pack includes grease capsule and battery 66 A8 1 RIK250 Remote installation kit - includes mounting bracket adapters and tubing for single point greasing 137 A8 1 NOTE: Order grease dispenser and service pack for initial operation. Wt. 309

310 Soft Start & Dynamic Brakes Gearmotors and Gear Products Accessories Industrial Grinders 600E Cast aluminum exhaust (gated) type wheel guards U.L. ed, C.S.A. Certified Wheel size 6 x 3/4 x 1/2 Unit (a) Cast aluminum non-exhaust type wheel guards U.L. ed, C.S.A. Certified Wheel size 6 x 3/4 x 1/2 Volts (b) Grinders Idle 600E Grinder 188 G1 1/ E Gr/Buffer 188 G1 1/ Unit (a) Volts (b) Idle 612 (f) Grinder 214 G1 1/ (f) Gr/Buffer 214 G1 1/ Grinders Generators Mod Express Baldor Education Workshops Index Baldor District Offices 623E D Cast iron exhaust type wheel guards Cast iron tool rest (except 612E & 662E) Wheel size 6 x 3/4 x 1/2 Unit (a) Volts (b) Idle 612E (c) (d) (f) Grinder 265 G1 1/ E (c) Grinder 300 G1 1/ ED (g) Grinder 406 G1 1/ E Grinder 300 G1 1/ E (c) (d) (f) Gr/Buffer 265 G1 1/ E (c) Gr/Buffer 300 G1 1/ Cast iron exhaust type wheel guards U.L. ed Wheel size 7 x 1 x 5/8 1/2 horsepower Unit (a) Unit (a) Volts (b) Volts (b) Phase Phase Idle Idle 712 (d) (f) Grinder 316 G (d) (f) Gr/Buffer 316 G E (d) (f) Grinder 373 G E (d) (f) Gr/Buffer 373 G (e) Grinder 408 G1 115/ (e) Grinder 408 G1 115/ (e) Gr/Buffer 408 G1 115/ (d) (e) Grinder 408 G / (d) (e) Grinder 408 G / Cast iron exhaust type wheel guards Water pot and lighted eyeshields U.L. ed Wheel size 7 x 1 x 5/8 1/2 horsepower except 7312D, rated 1/2 / 1/3 HP 7306D Grinder 527 G1 115/ D Grinder 527 G1 115/ D (d) Grinder 527 G / D Grinder 662 G / NOTE: (a) Grinders supplied with two grinding wheels, one 36 grit and one 60 grit. Grinder/Buffers supplied with one 36 grit grinding wheel and one wire brush wheel wire. (b) 115 Volt and 115/230 volt, single phase, 60 hertz units supplied with start/stop switch, 8 foot 3 conductor cord with plug connected for 115 volts /460 volt, three phase, 50/60 hertz units supplied with start/stop switch factory connected for volts. No cord and plug supplied. (c) U.L. ed. (d) C.S.A. Certified (e) Supplied with cast iron tool rests and exhaust type wheel guards. (f) Supplied with pressed steel tool rests and non-exhaust type guards except 612E, 662E, 712E and 762E which have cast iron exhaust type guards. (g) Supplied with GA24 water pot, GA25 tool tray and two lighted eyeshields wired through start/stop switch on single phase units only. Designed to comply with OSHA standards under normal usage.

311 Industrial Grinders 8100W Cast iron exhaust type wheel guards Cast iron tool rest Wheel size 8 x 1 x 3/4 Unit (a) Volts (h) Grinders Idle 8100W (c) Grinder 658 G1 3/4 115/ W (c) Grinder 658 G1 3/4 115/ W (c) Gr/Buffer 658 G1 3/4 115/ W (c) (d) Grinder 638 G1 3/ / W (c) (d) Grinder 638 G1 3/ / W Gr/Buffer 638 G1 3/ / W (c) Grinder 638 G1 3/ Soft Starters & Dynamic Brakes Gearmotors and Gear Products Accessories 8100WD Cast iron exhaust type wheel guards U.L. ed Cast iron tool rest Water pot & lighted eyeshields Wheel size 8 x 1 x 3/4 Unit (a) Volts (h) Idle 8100WD Grinder 752 G1 3/4 115/ WD Grinder 752 G1 3/4 115/ WD (d) Grinder 741 G1 3/ / WD (d) Grinder 741 G1 3/ / Grinders Generators 1022W 1022WD Cast iron exhaust type wheel guards U.L. ed Cast iron tool rest Wheel size 10 x 1 x 7/8 Unit (a) NOTE: (a) Grinders supplied with two grinding wheels, one 36 grit and one 60 grit. Grinder/Buffers supplied with one 36 grit grinding wheel and one wire brush wheel wire. (h) 115/230 volts, single phase, 60 hertz units supplied with 8 foot, 3 conductor cord with plug, and start/stop switch connected for 115 volts, reconnectable for 230 volts with plug change /460 volts, 3 phase, 50/60 hertz units supplied with start/stop switch factory connected for volts, reconnectable for 460 volts except 575 volt units are single voltage. 1022W, 1022WD, and 3 phase units supplied less cord and plug. (c) U.L. ed. (d) C.S.A. Certified Designed to comply with OSHA standards under normal usage. Volts (h) Idle 1022W Grinder 841 G / W (d) Grinder 829 G1 1 1/ / W (d) Grinder 829 G1 1 1/ Cast iron exhaust type wheel guards U.L. ed Cast iron tool rest Water pot & lighted eyeshields Wheel size 10 x 1 x 7/8 Unit (a) Volts (h) Idle 1022WD Grinder 963 G / WD (d) Grinder 950 G1 1 1/ / Mod Express Baldor Education Workshops Index Baldor District Offices 311

312 Soft Start & Dynamic Brakes Gearmotors and Gear Products Accessories Industrial Grinders 12 Inch Cast iron tool rests & exhaust type wheel guards 1800 idle Manual starter with overload protection Lighted eyeshields (bulb not included) Wheel size 12 x 1-1/4 x 2 (sold separately) 3 Phase suitable for 50/60Hz, single-phase 60Hz Less Wheels & Pedestal Volts Factory Connected Voltage Grinders Phase 1215W 1894 G / (j) W 1960 G / (j) W 2005 G / (j) W 1960 G NOTE: (j) Supplied with manual starter, connected at factory for 230 volts. Specify voltage when ordering. Grinders Generators Mod Express Baldor Education Workshops Index Baldor District Offices BALDOR #1215W with #GA20 Pedestal 14 Inch BALDOR #1407W with #GA20 Pedestal Cast iron tool rests & exhaust type wheel guards Suitable for 50/60Hz, 1500/1800 idle Magnetic starter with overload protection Lighted eyeshields (bulb not included) Wheel size 14 x 1-1/4 x 3 (sold separately) Less Wheels & Pedestal Volts Starter Provides Overload Protection Diameter Face Bore Grit 1406W 2430 G Magnetic W 2430 G Magnetic W 2430 G Magnetic W 2651 G1 7 1/2 230 Magnetic W 2651 G1 7 1/2 460 Magnetic W 2651 G1 7 1/2 575 Magnetic 374 Wheels for 14 Inch Grinders High quality aluminum oxide and silicon abrasive in a premium vitrified system B A / B A / Diameter Face Bore Grit B A / B A / NOTE: When installing new wheels, check wheels for possible damage. Do not use a damaged wheel. With new wheel installed, all safety guards in place and operator standing away from front of grinder, run grinder for one minute before apply work. (Wear safety glasses). Exercise caution. Designed to comply with OSHA standards under normal usage.

313 Industrial Grinders 6 Inch Diamond Wheel Tool Grinder #522 Features: 1/2, 3600 Idle, 60 Hz. Less Wheels Volts Phase Grinders 522 (k) 1058 G (l) 1058 G / NOTE: s include all parts pictured except wheels and bulb for lamp. Rough service bulb is suggested. Locked double row bearings. Guaranteed maximum runout on face at periphery. Grinder accommodates cup wheels 6" diameter 1" face recessed 4" dia. 1-1/2" deep, steel backed 1-1/4" center hole. Not CSA certified. (k) Supplied with reversing switch, 8 foot, 3 conductor cord and plug. (l) Supplied with reversing switch but less cord and plug,. Connected at factory for volts. Soft Starters & Dynamic Brakes Gearmotors and Gear Products Accessories Diamond Wheels #D501 Face Grit Description D A8 3/ General Purpose Diamond Wheel D A8 3/ Fine Finish Diamond Wheel NOTE: When installing new wheels, check wheel for possible damage. Do not use a damaged wheel. With new wheel installed and all safety guards in place, and operator is standing away from front of grinder, run grinder for one minute before applying work. (Wear safety glasses). Exercise caution. Grinders Generators 6 Inch Carbide Tool Grinder Features: 1/2, 3600 Idle, 60 Hz. Less Wheels Volts Phase 500 (k) 942 G (l) 942 G / NOTE: s include all parts pictured except wheels and bulb for lamp. Rough service bulb is suggested Grinder accommodates cup wheels 6" diameter 1" face recessed 4" dia. 1-1/2" deep, steel backed 1-1/4" center hole. Not CSA certified. (k) Supplied with reversing switch, 8 foot, 3 conductor cord and plug. (l) Supplied with reversing switch but less cord and plug,. Connected at factory for volts. Mod Express Baldor Education Workshops #500 #C61 Wheels and Accessories Face Grit Description C61 82 A Silicone Carbide C A Silicone Carbide S46 75 A Aluminum Oxide S61 75 A Aluminum Oxide GA8 90 A8 Wheel Dresser with Diamond NIB GA7 54 A8 Diamond NIB for GA8 (7/16 diameter x 1" long) Index Baldor District Offices NOTE: When installing new wheels, check wheel for possible damage. Do not use a damaged wheel. With new wheel installed and all safety guards in place, and operator is standing away from front of grinder, run grinder for one minute before applying work. (Wear safety glasses). Exercise caution. 313

314 Soft Start & Dynamic Brakes Industrial Abrasive Belt Grinders Three Position Tiltable Features: 1-1/2, Single and Three Phase Grinders Gearmotors and Gear Products Accessories Grinders Generators Mod Express Baldor Education Workshops Index Baldor District Offices # D # TD # TD # AS NOTE: Belt size 2 x48-80 grit. (c) U.L. ed (m) Supplied with 8 x1 x3/4-36 grit grinding wheel and 2 x48-80 grit belt.. (n) Supplied with start/stop switch, eight foot, three conductor cord and plug connected for 115 volts. (o) Supplied with start/stop switch connected for volts, less cord and plug. (p) Supplied with start/stop switch, connected for 115 volts, but less cord and plug. Not U.L. ed or CSA Certified. (q) Supplied with adjustable speed control, start/stop switch, eight foot, three conductor cord and plug. Not U.L. ed or CSA Certified. Volts Idle Phase TD (n) (c) 1110 G1 115/ TD (o) (c) 1077 G / TD (m) (p) 1304 G1 115/ TD (m) (o) (c) 1268 G / AS (q) 1196 G Stationary Abrasive Belt Grinder D (n) (c) 1014 G1 115/ D (o) (c) 980 G / Industrial Buffers #333B #1458 with #GA20 Pedestal Features: Buffers are designed for use with soft cloth wheels ONLY. Specific buffing applications may require the addition of operator safety devices. Consult with a safety engineer before installation. includes flanges and nuts but does not include wheels. Single phase buffers 60 hertz, 115/230 volts, except #114 and #111 which are 115 volts. All three phase buffers 50/60 hertz, /460 volts must be connected for specific voltage. Phase Idle Shaft Dia. 114 (r) 239 G1 1/ / (r) 239 G1 1/ / B (r) 471 G1 3/ / B (r) 471 G1 3/ / B (o) 459 G1 3/ / B (o) 459 G1 3/ / B (s) 624 G / B (s) 614 G1 1 1/ / B (o) 600 G1 1 1/ / B (o) 600 G1 1 1/ / (t) 1448 G / (t) 1406 G / (t) 1329 G / (t) 1292 G / (u) 1942 G / (u) 1653 G / (u) 1847 G1 7 1/ / (u) 1746 G1 7 1/ /4 223 (r) Supplied with eight foot, three conductor cord, plug and switch. (o) Supplied with start/stop switch connected for volts less cord and plug. (s) Supplied with switch less cord and plug. Connected at factory for 115 volts. (t) Supplied with manual starter, connected at factory for 230 volts. Specify voltage when ordering. (u) Supplied with magnetic starter, connected at factory for 230 volts. Specify voltage when ordering. s do not include pedestal. 314

315 Big Red Grinders 115 volt single phase 60Hz Cast aluminum exhaust (gated) type wheel guards U.L. ed, C.S.A. Certified Wheel size 6 x 3/4 x 1/2 Eight foot 3 conductor cord and plug Unit Idle Grinders 600RE Grinder 188 G1 1/ RE Grinder/Buffer 188 G1 1/ Soft Starters & Dynamic Brakes Gearmotors and Gear Products 600RE 115 volt single phase 60Hz Cast aluminum exhaust (gated) type wheel guards U.L. ed, C.S.A. Certified Wheel size 6 x 3/4 x 1/2 Eight foot 3 conductor cord and plug Unit Idle 612R Grinder 214 G1 1/ R Grinder/Buffer 214 G1 1/ volt single phase 60Hz U.L. ed, C.S.A. Certified Wheel size 7 x 1 x 5/8 Eight foot 3 conductor cord and plug Accessories Grinders Pedestals 812RE Unit NOTE: (v) Furnished with GA11 eyeshields and cast iron exhaust type guards. (w) Guards are non-exhaust type. Supplied with GA10 eyeshields. Idle 712R (w) Grinder 316 G1 1/ R (w) Grinder/Buffer 316 G1 1/ RE (v) Grinder 373 G1 1/ RE (v) Grinder/Buffer 373 G1 1/ volt single phase 60Hz U.L. ed Wheel size 8 x 1 x 3/4 Cast iron exhaust type wheel guards Generators Mod Express GA16R GA14R Lighted Eyeshields Unit Idle 812RE Grinder 623 G1 3/ RE Grinder/Buffer 623 G1 3/ Features: GA16R is cast iron base and top plate with steel column. GA14R is fabricated steel. GA16R GA16RE GA14R GA20RE Description For 6, 7, 8 grinders and grinder buffers. Cast Iron Height 32-7/8 base 15-3/4 wide x 14 deep. For 6 & 7 grinders all steel construction. Height 34 Light Industrial For 6, 7, 8 grinders and grinder buffers. Height 34-1/2. For 8 & 10 grinders all steel construction. Height 34 Light Industrial 265 A A A A8 54 Baldor Education Workshops Index Baldor District Offices Features: Cast aluminum frame, 5 1/2 x 3 3/4 viewing area. Description GA9R GA9SR GA9R GA9SR Fits Baldor 6-14 grinders. Supplied less bulbs, rough service bulbs are suggested. 60 watt. Same as GA9R except with On/Off switch. U.L. ed. CSA Certified. 111 (per pair) 123 (per pair) A8 5 A

316 Soft Start & Dynamic Brakes Gearmotors and Gear Products Accessories Accessories Dust Control Units for Baldor Grinders 115 Volt, Single Phase, 60 Hz. Dust Control Unit Grinding Wheel Maximum Dia. Width Total Cap. Cubic Ft/Min Required Per Wheel By OSHA (y) Grinders Air Control Valves DC7 798 A Yes 60 DC8 798 A Yes 62 DC A Yes (z) 60 DC A Yes (z) 62 DC A Yes (z) 57 DC14-3 (x) 1417 A Yes (z) 73 NOTE: (x) DC14-3 powered with 1 TEFC /460 volt, three phase motor, less cord, switch, and lug. (y) From ventilation section table G-4 Federal register vol. 37 #202, (z) Air control valve required to direct total CFM of collector to only the wheel being used to meet OSHA CFM requirements on 10 and larger grinders. Grinders Generators Mod Express Baldor Education Workshops Index Baldor District Offices 316 #1022W with DC10 and GA16 Replacement Filter Bags Dust Control Unit ARB-1 54 A8 DC7, 8, 10, 12, 12-3 ARB-2 75 A8 DC14-3 NOTE: Do not collect potentially reactive materials without consulting (NFPA) National Fire Protection Association Standards. Powered by a 1/2 TEFC single phase Baldor motor with cord, switch, and plug. 230 volt single phase units are available and supplied less switch, cord, and plug. Specify for 230 volt single phase operation. Collectors with three phase motor less cord, switch, and plug are available. For /460 volt three phase, add suffix -3 to catalog number. Add $30.00 to list price. Mount dust control units with Grinder and GA16 or GA20 pedestal. Accessories Grinder and Buffer L A D I B E G K M H F C J Item A GA16 GA16E Description Pedestal Cast Iron Steel A B GA14 Pedestal Steel 200 A8 64 C GA20 GA20E Pedestal Cast Iron Steel D GA24 Water Pot 28 A8 1 E GA3 Water Pot 44 A8 7 F GA25 Tool Tray 29 A8 9 G GA4 Tool Tray 44 A8 6 H GA11 Eyeshield 35 pr A8 2 I GA10 Eyeshield 32 pr A8 1 J GA9 Lighted Eyeshield (less on/off switch) 111 pr A8 5 J-1 GA9-1 same as GA9 except packed 1 unit per carton 60 ea A8 3 K GA9S Lighted Eyeshield (with on/off switch) 123 pr A8 6 L GA13 Eyeshield for 6 Grinders 27 pr A8 2 M AB248 Abrasive Belt 2" x 48" 80 Grit 17 A8 1 (A) GA16 Pedestal for 6", 7", 8" and 10" grinders, carbide and diamond wheel grinders, 1/4 through 1-1/2 buffers and belt grinders. Height 32 7/8". GA16RE for 6 & 7 grinders all steel construction. Height 34. (B) GA14 Pedestal fabricated steel, for 6", 7", 8" and 10" grinders, 1/4 through 1 1/2 buffers. Height 34 1/2". (C) GA20 Pedestal for 8", 10", 12" and 14" grinders and 3/4 through 7-1/2 buffers.height 30". GA20RE for 8 & 10 grinders all steel construction. Height 34. (D) GA24 Water Pot for 623E, 673E, 612E, 662E, and 7" (except #712, #712R, #762, & #762R), 8" and 10" grinders. Supplied with mounting bracket and swivel arm. Capacity 1-1/2 pints. (E) GA3 Water Pot for GA20 pedestal. Capacity 3 pints. (F) GA25 Tool Tray for 623E, 632E, 673E, 612E, 662E and 7" (except #712, #712R, #762, & #762R), 8" and 10" grinders. Supplied with mounting bracket and swivel arm. Diameter 8". Area 48 square inches. (G) GA4 Tool Tray for GA20 pedestal. Dimensions 12" x 6". (H) GA11 Eyeshield 6" x 4" shatter resistant Plexiglas. Fits Baldor grinders 7 through 14. (I) GA10 Eyeshield 5" x 4" shatter resistant Plexiglas. Fits Baldor 6" grinders and #712, #712R, #762 and #762R. (J) GA9 Lighted Eyeshield 5 1/2" x 3 3/4" viewing area made of shatter resistant Plexiglas. Supplied with 8 foot 3 conductor cord with plug. Accommodates standard 115 volt 60 watt bulb. Supplied less bulb and on/off switch. Mounts to Baldor grinders except tool and belt grinders. Adjusts horizontally and vertically. U.L. listed/csa certified. (J-1) GA9-1 Same as GA9 except packed 1 per carton. 115 volt only. (K) GA9S Lighted Eyeshield with On/Off Switch volt only. (L) GA13 Eyeshield for 600 Series 6 Grinders (M) AB248 Abrasive Belt 2" x 48" 80 Grit. A

317 Accessories Wheels for Grinders 6" 7" 8" 10" 12" 14" Grinders Extremely durable aluminum oxide abrasive grain. Excellent for steels and alloy steels. Ideal for numerous general purpose applications. Diameter Face Bore Grit B66 21 A8 6 3/4 1/ B67 21 A8 6 3/4 1/ B73 30 A / B74 30 A / B80 37 A / B81 37 A / B A / B A / B A / B A / B A / B A / Soft Starters & Dynamic Brakes Gearmotors and Gear Products Accessories Sewed Cotton Buffing Wheels Features: Wheels are muslin cloth, spiral sewn. These bore sizes will fit shafts 1/8 greater diameter than bore. Diameter Face Bore A65 12 A8 6 1/4 1/2 1 A82 19 A8 8 1/4 3/4 1 A A8 10 1/4 7/8 1 6" 8" 10" NOTE: Cotton wheels are supplied in sections 1/4 wide. Two (or more) sections may be put together to make up wheel of desired width. Grinders Generators Mod Express Wire Brush Wheels 6" 7" 8" Features: Wheels are crimped, carbon steel wire. Diameter Face Bore Diameter of Wire W64 27 A8 6 5/8 1/ W70 32 A8 7 5/8 5/ W82 36 A8 8 3/4 3/ NOTE: Baldor 6, 7 & 8 grinders equipped with grinding wheels can be converted to have wire brush wheels. To properly fit the wire brush wheels, flat washers or spacer must be placed on both sides of the wheel flanges. This will accommodate the width differences between the wire brush wheel and the original grinding wheel. Order washers/spacers as follows: 6 (3) HW1000A50, 7 (2) HA2047A01, 8 (4) HW1000A75 Baldor Education Workshops Index Baldor District Offices NOTE: When installing new wheels, check wheel for possible damage. Do not use a damaged wheel. With new wheel installed and all safety guards in place, and operator standing away from front of grinder, run grinder for one minute before applying work. (Wear safety glasses). Exercise Caution. 317

318 Soft Start & Dynamic Brakes Gearmotors and Gear Products Polishing Lathes, Chucks Baldor Super-Saver Polishing Lathes Features: Standard tapered shaft. No. of Speeds Volts Hertz Grinders Lbs. Kg G1 1/ / G1 1/ / Accessories Grinders Generators Mod Express Baldor Education Workshops Index Baldor District Offices R1 R2 L3 L4 R5A R6 L7 Dust Collector Bags Baldor Polishing Lathes Features: Standard tapered shaft. Baldor Heavy Duty Laboratory Lathes Features: Wells Quick Change Chuck on #380WCT. No. of Volts Hertz Speeds Lbs. Kg 380WCT 825 G1 1/ / T 358 G1 1/ / NOTE: 380WCT shipped complete with Wells Quick Chuck installed. Includes 2 mandrels, 2 stones, 1 arbor, and 1 spiral chuck. Baldor Heavy Duty Single Shaft Lathes Features: Straight Shaft - 5/8" diameter. Baldor True-Running Chucks Description Lbs. R1 14 A8 Hard Wheel, Right Hand, Brass R2 15 A8 Soft Wheel, Right Hand, Brass L3 14 A8 Hard Wheel, Left Hand, Brass L4 15 A8 Soft Wheel, Left Hand, Brass R5A 53 A8 Burr Chuck, Right Hand, R6 27 A8 Arbor Band, Right Hand, Brass L7 29 A8 Burr Chuck, Left Hand, Stainless NOTE: R1 & L3 hard wheel chucks accommodate up to 1/4 wide wheel with 1/4 arbor hole. R6 arbor band chuck accommodates 1/2 wide x 3/4 diameter arbor band. DA1 29 A8 No. of Speeds Volts Hertz Description Dust Collector Bag (1 per carton). For Baldor D60 and D61 Dust Collectors Lbs. Kg 353T 321 G1 1/ / T 322 G1 1/ No. of Speeds Volts Hertz Lbs. Kg LPL A8 1/ LPL A8 3/ / Kg Lbs. Kg FULL THREE YEAR WARRANTY Baldor polishing lathes are warranted against burnouts, defective materials, and workmanship for three full years. Warranty covers all parts except those subject to normal wear. Wells Quick Chuck warranted one year by manufacturer. 318

319 Premier Portable Generators ( Featured) OHV30 OHV85E 3,000 through 11,000 Watts Generators Applications Baldor portable generators are designed to meet your demands when dependable portable power is required. The performance and durability of Baldor portables have made them the generator of choice for industrial and rental/construction applications. Features Baldor portable generators are equipped with industrial grade engines to provide the performance and dependability you can count on. Baldor manufactures it s own generators and backs them with an industry leading 3-year limited warranty. Baldor portable generators also feature Switchless Pow R, eliminating the need for a Power switch. Automatically get the 120V or 240V nameplate power rating without having to flip a switch. Baldor Premier portable generators incorporate the features you ve come to expect from the leader in portable power generation. Switchless Power Automatic 120V/240V operation. Automatic Idler System Reduces fuel consumption, extends engine life. Focal Vibration System Reduces vibration, extends generator life. Hour meter Voltmeter Fuel Gauge Soft Starters & Dynamic Brakes Gearmotors and Gear Products Accessories Grinders Generators Max. Watts Cont. Watts Fuel Capacity Engine Engine Volts (60 Hertz) OHV Gal. Honda VAC 1535 PG 121 OHV Gal. Honda /240 VAC 2181 PG 170 OHV50H Gal. Honda /240 VAC 2380 PG 189 OHV Gal. Honda /240 VAC 2807 PG 214 OHV60E Gal. Honda /240 VAC 3270 PG 226 OHV85E Gal. Vanguard /240 VAC 3697 PG 251 OHV100E Gal. Vanguard /240 VAC 6209 PG 316 OHV110E Gal. Honda /240 VAC 6914 PG 340 NOTES: OHV60E, OHV85E, and OHV100E are electric start and have recoil start. OHV110E has electric start but no recoil. 1 Batteries are not included or available on any Electric Start Models. Baldor reserves the right to implement specifications or design change without notice. WARNING: Do not connect generator to any building s electrical system unless a disconnect switch has been installed. Follow local and national electrical codes for proper installation. WARRANTY: Three-year limited warranty See Baldor Generators Warranty Policy for details. Engine Warranty per the Engine Manufacturer. Approx. Mod Express Baldor Education Workshops Index Baldor District Offices 319

320 Soft Start & Dynamic Brakes Gearmotors and Gear Products Accessories Grinders Generators Mod Express Baldor Education Workshops Index Baldor District Offices Baldor Premier Portable Generator Specifications Generators Premier Model OHV30 OHV40 OHV50H OHV60 OHV60E OHV85E OHV100E OHV110E Features Switchless Pow R std std std std std std std AC Voltmeter std std std std std std std Hourmeter std std std std std std std std AC Circuit Breakers std std std std std std std std Low Oil Shutdown std std std std std std std std Automatic Idler std std std std std std std Spark Arrestor Muffler std std std std std std std std Extended Run Fuel Tank std std std std std std std std Tubular Roll Cage std std std std std std std std Neoprene Isolators std std std std std std std std Focal Vibration System (FVS) std std std std std std std 3-Year Warranty 2 std std std std std std std std Engine Model Honda Honda Honda Honda Honda Vanguard Vanguard Honda Horsepower Cylinder (S) Lubrication System Splash Splash Splash Splash Splash Pressure Pressure Pressure Displacement - CC Starting Systems 1 Recoil Recoil Recoil Recoil 12 Volt with Recoil 12 Volt with Recoil 12 Volt with Recoil Rating Max Rating 3000W 4000W 5000W 6000W 6000W 9000W 10500W 11000W Rated 2500W 3500W 4000W 5000W 5000W 8000W 9500W 10000W Volts 120VAC 120/240VAC 120/240VAC 120/240VAC 120/240VAC 120/240VAC 120/240VAC 120/240VAC Amps / / / / / / /41.6 db 7 meters Receptacles Straight(520R)120V, 20A, Duplex 1 Straight(520R GFCI)120V, 20A, Duplex Twist Lock(L530R)120V, 30A Twist Lock(L1430R)120/240V, 30A Twist Lock(CS6369)120/240V, 50A 1 1 Fuel System Fuel Capacity (U.S. Gallons) Operation Run Time/ 5 hrs. 5 hrs. 6 hrs. 4 hrs. 4 hrs. 4 hrs. 4 hrs. 4 hrs. Operation Run Time/Half 8 hrs. 9 hrs. 10 hrs. 7 hrs. 7 hrs. 7 hrs. 6 hrs. 6 hrs. Dimensions Length " Width " Height " Weight (Net Dry) 112 lbs 170 lbs 170 lbs 192/206 lbs 192/206 lbs 224 lbs 270 lbs 270 lbs NOTES: 1 Batteries are not included or available on any Electric Start Models. 2 Proper engine maintenance is required. Engine warranty per manufacturer. Baldor reserves the right to implement specifications or design changes without notice. WARNING: Do not connect generator to any building s electrical system unless a disconnect switch has been installed. Follow local and national electrical codes for proper installation. 12 Volt 320

321 Powerchief Portable Generators (Maximum Value) 1,100 through 9,000 Watts Generators Baldor Generators are known for their quality and performance and the Powerchief Series provides what you ve come to expect in a maximum value generator. All Powerchief generators feature industrial grade engines, a Baldor generator with 3-year limited warranty, Switchless Pow R and Focal Vibration System. Soft Starters & Dynamic Brakes Gearmotors and Gear Products PC60H Max. Watts Cont. Watts Fuel Capacity Engine Engine Volts (60 Hertz) Approx. Shp. PC11R Qt. Robin VAC/12 VDC 1054 PG 55 PC30H Qt. Honda VAC 1345 PG 108 PC40H Gal. Honda /240 VAC 1743 PG 162 PC50H Gal. Honda /240 VAC 1965 PG 200 PC60H Gal. Honda /240 VAC 2179 PG 207 PC60HE Gal. Honda /240 VAC 2729 PG 213 PC90VE Gal. Vanguard /240 VAC 2946 PG 232 NOTES: 1 Batteries are not included or available on any Electric Start Models. Baldor reserves the right to implement specifications or design changes without notice. WARNING: Do not connect generator to any building s electrical system unless a disconnect switch has been installed. Follow local and national electrical codes for proper installation. Accessories Grinders Generators Powerchief Generators with Inverter Technology PC32Ri 1,650 through 4,300 Watts Baldor Powerchief inverter generators are powered by air-cooled, 4-Cycle, industrial gasoline engines. An inverter converts DC current into standard household AC current. This new technology now allows inverters to be highly efficient in conjunction with a generator. High quality electrical output power is comparable to public utility sources. Powerchief inverter generators are ideal for powering computers & equipment sensitive to voltage surges. Features: Very Low Noise - quieter operation Compact & Lightweight - greater efficiency allows reduction in overall size & weight Low Fuel Consumption - inverter technology, combined with throttle control, automatically adjusts engine speed to electrical load, reducing fuel use Mod Express Baldor Education Workshops Index Max. Watts Cont. Watts Fuel Capacity Engine Engine Volts Approx. PC17RI Qt. Robin VAC/12 VDC 1737 PG 45 PC32RI Gal. Robin VAC/12 VDC 3048 PG 130 PC43RI Gal. Robin VAC/12 VDC 3905 PG 143 NOTES: 1 PC32Ri and PC43Ri are electric start. Baldor District Offices 321

322 Soft Start & Dynamic Brakes Gearmotors and Gear Products Accessories Grinders Generators Mod Express Baldor Education Workshops Index Baldor District Offices Baldor Powerchief Portable Generator Specifications Generators Powerchief Model PC11R PC30H PC40H PC50H PC60H PC60HE PC90VE PC17Ri* PC32Ri* PC43Ri* Features Switchless Pow R std std std std std DC Circuit Breakers std std std std AC Circuit Breakers std std std std std std std std std std Low Oil Shutdown std std std std std std std std std std Spark Arrestor Muffler std std std std std std std std std std Extended Run Fuel Tank std std std std std std std Tubular Roll Cage std std std std std std Neoprene Isolators std std std std std std std std std std Focal Vibration System (FVS) std std std std std 3-Year Warranty 2 std std std std std std std std std std Engine Model Robin Honda Honda Honda Honda Honda Vanguard Robin Robin Robin Horsepower Cylinder (S) Displacement-CC Starting Systems 1 Recoil Recoil Recoil Recoil Recoil 12 Volt with Recoil 12 Volt with Recoil Recoil 12 Volt with Recoil 12 Volt with Recoil Rating Max Rating 1100W 3000W 4000W 5000W 6000W 6000W 9000W 1650W 3200W 4300W Rated 900W 2500W 3500W 4000W 5000W 5000W 8000W 1400W 2800W 3800W Volts 120VAC/ 12VDC 120VAC 120/240VAC 120/240VAC 120/240VAC 120/240VAC 120/240VAC Amps / / / / / db 7 meters Receptacles Straight (515R) 120V, 15A, Single 1 Straight (515R) 120V, 15A, Duplex 1 Straight (520R GFCI) 120V, 20A, Duplex Twist Lock (L530R) 120V, 30A Twist Lock (L1430R) 120/240V, 30A Fuel System Fuel Capacity (U.S. Gallons) 4.2 qt 3.8 qt 4.6 gal 4.6 gal 4.6 gal 4.6 gal 4.6 gal 4.2 qt 3.7 gal 4.2 gal Operational Run Time/ Tank 2.5 hr 1.5 hr 4 hr 6 hr 4 hr 4 hr 3.2 hr 2.4 hr 5 hr 3.9 hr Operational Run Time/Half Tank 4.2 hr 2.3 hr 7 hr 10 hr 7 hr 7 hr 5.6 hr 4 hr 8.4 hr 6.6 hr Dimensions Length " 22.8" Width " 20.7" Height " 24.3" Weight (Net Dry) 55 lbs 94 lbs 162 lbs 162 lbs 187/193 lbs 187/193 lbs 217 lbs 45 lbs 130 lbs 143 lbs NOTES: * Inverter generator. 1 Batteries are not included or available on any Electric Start Models. 2 Proper engine maintenance is required. Engine warranty per manufacturer. Baldor reserves the right to implement specifications or design changes without notice. WARNING: Do not connect generator to any building s electrical system unless a disconnect switch has been installed. Follow local and national electrical codes for proper installation. 120VAC/ 12VDC 120VAC/ 12VDC 120VAC/ 12VDC 322

323 Diesel Portable Generators 3,300 through 6,000 Watts Generators Baldor diesel generators are designed for rugged applications where diesel fuel is readily available. Whether your application is industrial, farm or rental/ construction your Baldor diesel generator is built to deliver dependable quality portable power. These generators are fully equipped with a volt meter and hour meter and like the rest of Baldor generators they are backed by a 3-year limited warranty. Soft Starters & Dynamic Brakes Gearmotors and Gear Products DG3E Max. Watts Cont. Watts Fuel Capacity Engine Engine Volts (60 Hertz) Approx. Shp. DG3E Gal Hatz /240 VAC 3582 PG 175 DG6E Gal Hatz /240 VAC 4995 PG 254 NOTES: 1 Batteries are not included or available on any Electric Start Models. Baldor reserves the right to implement specifications or design changes without notice. WARNING: Do not connect generator to any building s electrical system unless a disconnect switch has been installed. Follow local and national electrical codes for proper installation. Accessories Grinders Portable Generator Accessories Baldor offers several accessories for portable generators to enhance portability and easy connection when standby power is needed. Dolly kits are available in 2 or 4 wheel designs and are easy to install. Transfer switches come with indoor rated manual transfer switch, installed circuit breakers, and 25 extension cord ready to connect the transfer switch and generator. Power inlet box kits are also available to provide an outdoor rated connection point for the generator. Generators Mod Express PGD2 PGD4 GTK30A10 GTK50A12 GTK30PBK GTK50PBK Description Features Available for Models 2 Wheel Dolly Kit 4 Wheel Dolly Kit Manual Transfer Switch Kit - 10 Circuit Manual Transfer Switch Kit - 12 Circuit Power Inlet Box Kit Power Inlet Box Kit Two 10 Pneumatic Wheels, Fold Down Handles, Cable Storage Hanger, and Mounting Hardware Four 10 Pneumatic Wheels, Fold Down Handles, Cable Storage Hanger, and Mounting Hardware Indoor Rated Transfer Switch and 25 Generator Ext Cord with L1430 Conn. Transfer Switch Includes circuit breakers, 3-15A 1-Pole, 3-20A 1-Pole, 1-20A 2-Pole, 1 30A 2-Pole, 1 30A 2- Pole Generator Main and 1 60A 2-Pole Main. Indoor Rated Transfer Switch and 25 Generator Ext Cord with CS6364/5 Conn. Transfer Switch Includes circuit breakers, 3-15A 1-Pole, 3-20A 1-Pole, 1-20A 2-Pole, 1 30A 2-Pole, 1 30A 2- Pole Generator Main and 1 60A 2-Pole Main. Outdoor Rated Power Inlet Box with 30 Amp L1430 Plug for connection to Generator Extension Cord. Includes Mating Plug for Transfer Switch connection. Outdoor Rated Power Inlet Box with 50 Amp CS5365 Plug for connection to Generator Extension Cord. Includes Mating Plug for Transfer Switch connection. Premier, Powerchief and Diesel Models 4,000 to 9,000 Watt Premier, Powerchief and Diesel Models 4,000 to 11,000 Watt Premier, Powerchief and Diesel Models 4,000 to 11,000 Watt Premier, Models 10,000 to 11,000 Watt Approx. Shp. 208 G G G G8 45 GTK30A10 Transfer Switch 116 G8 4 GTK50A12 Transfer Switch 140 G8 5 Baldor Education Workshops Index Baldor District Offices 323

324 Soft Start & Dynamic Brakes Gearmotors and Gear Products Accessories Grinders Generators Mod Express Baldor Education Workshops Index Baldor District Offices Baldor Diesel Portable Generator Specifications Portable Diesel Model DG3E DG6E Features Switchless Pow R std std AC Voltmeter std std Hourmeter std std AC Circuit Breakers Low Oil Shutdown std std Spark Arrestor Muffler std std Extended Run Fuel Tank std std Tubular Roll Cage std std Neoprene Isolators std std Focal Vibration System (FVS) std std 3-Year Warranty 2 std std Engine Model Hatz 1B30 Hatz 1B40 Horsepower Cylinder (S) 1 1 Displacement - CC Starting Systems 1 12 Volt with Recoil 12 Volt with Recoil Rating Max Rating Rated Volts 120/240 VAC 120/240 VAC Amps 25/ /22.9 db 7 meters Receptacles Straight (520R GFCI) 120V, 20A, Duplex 1 2 Twist Lock (L530R) 120V, 30A 1 1 Twist Lock (L1430R) 120/240V, 30A 1 Twist Lock (L1420R) 120/240V, 20A 1 Fuel System Fuel Capacity (U.S. Gallons) Operational Run Time/ Tank 5.4 hr 4.6 hr Operational Run Time/Half Tank 9 hr 6 hr Dimensions Length Width Height Weight (Net Dry) 172 lbs 246 lbs NOTES: 1 Batteries are not included or available on any Electric Start Models. 2 Proper engine maintenance is required. Engine warranty per manufacturer. Baldor reserves the right to implement specifications or design changes without notice. WARNING: Do not connect generator to any building s electrical system unless a disconnect switch has been installed. Follow local and national electrical codes for proper installation. Generators 324

325 Mod Express Modification Mod Express Page No. Soft Starters & Dynamic Brakes M1 Balance M1A Dynamic Balance of Rotors M2 Bearings M2A Sealed or Double Shielded M2B Ball to Roller M2C Bearing Thermocouples M2D Bearing RTD S M2E Add Double Sealed Bearings up to a 365T M3 Brake M3A Convert Standard to Weatherproof M3B Convert to Vertical Mounting M3C Add Larger or Smaller Brake M3D Electrical Modifications M3E Add a Double C-Face or Coupler Brake M3F Remove Brake from a Brake M4 Conduit Box M4A Tap or Provide Additional Lead Hole M4B Rotate Conduit Box Lead Opening M4C Add Second Oversized Cast Iron Conduit box M4D Add Small Accessory Box M4E Add 3.5 Round Accessory box M4F Replace Die Cast Aluminum Conduit Box M5 Cord M5A Install Line Cord in Conduit Box or Terminal Panel M5B Install 6 Foot, 3 Conductor, Type SO Cord M6 Switch M6A Install Switch, Cord and Plug M6B Change from Mechanical to Electronic Switch M7 Drains M7A Add Condensation Drain Holes M7B Install T Drain M7C Close Standard Condensation Drain Holes M7D Add Breather Drain to Cast Iron Explosion Proof M8 Dripcovers M8A Install Dripcover on TEFC or ODP M9 Encapsulation M9A Encapsulate Winding Endturns M10 Leads M10A Install Terminal Lugs M10B Reconnect from Nine Leads to Three Leads M10C Re-mark Leads M10D Longer Leads M11 Lubrication M11A Install Low Temperature Bearing Lubricant M11B Add High Temperature or Customer Supplied Grease M12 Seals M12A Install Oil Seals M12B Install Inpro/Seal Gearmotors and Gear Products Accessories Grinders Generators Mod Express Baldor Education Workshops Index Baldor District Offices 325

326 Soft Start & Dynamic Brakes Mod Express Modification Mod Express Page No. Gearmotors and Gear Products Accessories Grinders Generators Mod Express Baldor Education Workshops Index Baldor District Offices M13 Mountings M13A Add Rigid Base M13B Install C-Face - Steel Band Construction M13C Install C-Face - Cast Iron Construction M13D Add D-Flange M13E Remove Rigid Base M13F Convert to F-2, Sidewall or Ceiling Mount M13G Install C Face to Explosion Proof M13H Mount Dust Control Unit on Grinders M13I Mount Grinder or Buffer onto a Pedestal and Package for Shipment M13J Add Adjustable Bases Mounting Diagrams M14 Export Packaging M14A Box, Package and Crate M15 Nameplate M15A Provide Auxiliary Data Plate M15B Replace/Add Customer Nameplate M15C Replace with Stainless Steel Nameplate M15D Add Bearing Data Nameplate M15E Mail Nameplates To District Offices M16 Blowers M16A Add Constant Velocity Blower Unit M16B Convert from a Three Phase to a Single Phase Blower M17 Paint M17A Paint to Baldor Stock Color M17B Paint to Customer Color M18 Lifting Lugs M18A Add Lifting Lugs up to a 326T Size M19 Screens M19A Add Rodent Screens to Open Drip-Proof M20 Hardware M20A Exchange Plated Hardware for Stainless Steel M21 Space Heaters M21A Add Space Heaters to TEFC or Open M21B Add Conduit Box for Thermostat or Heater Leads M22 Textile Service M22A Lint Proof Fan Cover M23 Thermal Protectors M23A Thermostats M23B Exchange Thermal Overload M23C Install Resistance Temperatures Dectectors M24 Thermocouples M24A Iron Constantan M25 Thermistors M25A One or Two Thermistor M25B Three Thermistors 326

327 Mod Express Modification Mod Express Page No. Soft Starters & Dynamic Brakes M26 Tropicalization M26A Protection of Windings and Mechanical Parts M27 Weatherproofing M27A Treatment of Windings and Mechanical Parts M28 Marine M28A IEEE 45 M29 Shaft Modifications M29A Drill and Tap or Flat M29B Convert from TEFC to TEAO M29C Threading M29D Shorten by 1/4 or Reduce Diameter M29E Shaft Grounding Brush M29F Shorten Shafts without Reducing the Overall Dimension M29G Special Shafts M29H Convert to a Longer Shaft up to a 215 M29I Machine Explosion Proof Shafts from T to a U M30 Grounding Screws M30A Add Grounding Screw on Endplate M31 Tach and Encoder Mounting Kits M31A Add Tach Mounting Kits to DC M31B Add Tach Mounting Kits with BTG1000 Tach M31C Add Tach Mounting Kits with XPY Tach M31D Add Encoder Kit to Inverter Duty M32 Testing M32A Performance Testing Per IEEE 112 M32B Witnessed IEEE 112 Performance Testing M33 Short Test M33A Short Test M34 Worm Gear Modifications M34A Install Bases on Worm Gear Speed Reducers M34B Convert From Single to Double End Output Shaft on Worm Gear Speed Reducers M34C Convert Output Shaft from Left Hand to Right Hand or Vise Versa on 900 or Universal Series Reducers M34D Install on 900 F-Series or Universal STF-Series Reducers M35 Terminal Blocks (50Hz, 3 Phase Only) M35A Install Terminal Blocks in Conduit Box and Connect Leads M36 Starters M36A Add Magnetic or Manual Starter to Grinder or Buffer Starter Single Phase M36B Add Magnetic or Manual Starter to Grinder or Buffer Starter Three Phase M36C Add Magnetic or Manual Starter to Grinder or Buffer Magnetic Starter Three Phase M36D Overload Protection for Dust Control Unit M37 Voltage M37A Change a Grinder Dust Control Unit to a 575 Volt M38 Receptacles M38A Meltric Receptacles M38B Brad Power Receptacles Gearmotors and Gear Products Accessories Grinders Generators Mod Express Baldor Education Workshops Index Baldor District Offices 327

328 Soft Start & Dynamic Brakes Mod Express Mod Express Gearmotors and Gear Products Accessories Ordering Information To order, specify the catalog number of the stock product and the MOD number. Use the motor discount for motor and list prices for the modification. Lead times indicated are subject to availability of stock motors in the Fort Smith Warehouse. Customer will absorb all freight costs when motor is shipped to Fort Smith from field warehouses. NOTE: Some modifications do not apply to explosion-proof motors. Contact Baldor for Approval. Grinders Generators Mod Express Baldor Education Workshops Index Baldor District Offices MOD Express Cancellation Policy Should it be necessary to cancel an order for a motor after it is modified, but before it ships a cancellation charge of double the modification charge will be invoiced to the customer. Any MOD order cancelled before modification is completed is subject to 25% cancellation charge. Once shipped, modified motors returned at purchaser's expense will be invoiced at double the MOD fee plus 10% restock fee. NOTICE No charge orders will no longer be accepted nor processed. This includes warranty replacement orders. The correct method is to charge for the replacement order and issue credit for the first order. We will continue to fix any Mod Express error at no charge to our customer. Note All lead times indicated are subject to availability of stock motors and parts in the Fort Smith warehouse. Please check stock availability before quoting lead time. Some conversions may not be allowed if they result in a change of operating parameters that affect efficiency or change the classification of EPAct motors. Modification prices do not include the cost of the motor, speed reducer, etc. 328

329 Modification Mod Express Description and Mod Express Working Days Required Soft Starters & Dynamic Brakes M1 M1A Balance Dynamic Balance of Rotor Re-balance stock motor to special balance 42 through 5011L TWO DAYS Gearmotors and Gear Products NOTE: Balance units are for velocity in inches per second. 449T - up perform in Charlotte. Contact Baldor for time. Squirrel Cage Type Standard Balance Special Balance Per T 0.15 /s 0.08 /s T - 447T 0.15 /s 0.08 /s T 0.15 /s 0.10 /s S- 5011L 0.15 /s 0.10 /s 503 DC /s 0.08 /s /s 0.08 /s /s 0.08 /s 327 Accessories Grinders Generators M2 M2A Bearings Sealed 42 through 215T AC stock motors have double shielded bearings as standard. DC motors have sealed bearings. This modification provides the option of replacing standard bearings in AC motors with sealed bearings. Per Sealed T T T 133 NOTE: The above modifications are not recommended for 254T and larger TEFC motors. Contract your Baldor Representative. Grease fittings will be replaced with slotted head pipe plugs unless otherwise specified. TWO DAYS Mod Express Baldor Education Workshops Index Baldor District Offices 329

330 Soft Start & Dynamic Brakes Modification Mod Express Description and Mod Express Working Days Required Gearmotors and Gear Products Accessories Grinders Generators Mod Express Baldor Education Workshops Index Baldor District Offices M2 M2B Bearings Ball to Roller 1800 or Below Roller bearings have the capability to handle higher radial loads than ball bearings, but must have minimum radial loads to operate correctly. Roller bearings must only be used in belted loads. they are not suitable for direct-coupled loads. Conversion of any motor to roller bearings should not be performed unless Baldor evaluates the belt load. A roller bearing evaluation sheet must be filled out and calculated by Baldor. Contact your District Office for details. See page 20 for motors stocked with roller bearings. Does Not Apply to Explosion-Proof NOTE: 447T - 4 pole and slower only. Perform in Charlotte. Contact Baldor for time and freight to ship motor to Charlotte plant. M2C M2D Add Thermocouple to Bearing Housing Iron constantan thermocouples unless specified otherwise. Install Bearing Temperature Detector 100 OHM Platinum Standard. (10 OHM and 120 OHM available) 449T L 1775 NOTE: Leads for thermocouples or RTD s are brought into separate terminal housing. includes adder for M4E. Perform in Charlotte. Contact Baldor for time and freight to ship motor to Charlotte plant. M2E Per T T L L T L 817 NOTE: Perform in Charlotte. Contact Baldor for time and freight to ship motor to Charlotte plant. Add Double Sealed Bearings 254T Through 365T, Open Steel Band Only Stock motors have double shielded bearings as standard. Per Bearing Per Bearing Per Sealed 254T - 256T T - 286T T - 326T T - 365T 380 CONTACT YOUR BALDOR REPRESENTATIVE -CONTACT YOUR BALDOR REPRESENTATIVE CONTACT YOUR BALDOR REPRESENTATIVE TWO DAYS NOTE: Grease fittings will be replaced with slotted head pipe plugs. 330

331 Modification Mod Express Description and Mod Express Working Days Required Soft Starters & Dynamic Brakes M3 M3A Brake Brake Rating lb-ft Convert Standard to Weatherproof Standard base mounted, TEFC brake motors will be converted to W/P brake motors. Includes replacement of standard brake with W/P brake of the same rating and weatherproofing of motor (See M27). Per Brake Rating lb-ft Per CONTACT YOUR BALDOR REPRESENTATIVE Gearmotors and Gear Products Accessories Grinders NOTE: TENV, C-Face brake motors can be converted also. TEFC C-Face brake motors cannot be converted. M3B Brake Rating lb-ft Convert to Vertical Mounting Standard brake motors will be modified so that brakes will be operable in a brake-below motor or a brake-above motor vertical mounting position. NOTE: Specify if brake is to be above or below motor Per Explosion-Proof Per -Additional N/A CONTACT YOUR BALDOR REPRESENTATIVE Generators Mod Express Baldor Education Workshops M3C Add Larger or Smaller Brake (All Types) Contact Baldor for application assistance. $202 list per brake (plus difference in brake cost) CONTACT YOUR BALDOR REPRESENTATIVE Index Baldor District Offices 331

332 Soft Start & Dynamic Brakes Modification Mod Express Description and Mod Express Working Days Required Gearmotors and Gear Products Accessories M3 M3D Brake continued... Electrical Modifications Brake coils will be changed to allow operation from different voltage supplies for both 50 and 60 hertz AC or from DC supplies. External brake coil lead connections will be brought from the brake or from the motor conduit box when necessary in the application. Specify brake lead location, voltage of brake coil, frequency of supply source. (Allow 2 weeks for brake coil delivery.) $186 per brake (plus any difference in coil cost). CONTACT YOUR BALDOR REPRESENTATIVE Grinders Generators Mod Express Baldor Education Workshops M3E M3F Add a Double C-Face Coupler Brake Double C-Face coupler brakes. Mounts on motors with C- Face. Provides C-Face mounting on brake. Spring set, electrically released. NOTE: Brake Rating lb-ft Brake Mounting Per 3 56C C TC TC TC 1523 Rating up to a 105 ft. lb. is available. Contact Baldor Representative for approval and delivery time. Remove Brake From a Brake Brake is removed for customers who will be supplying a brake at their location. Brake Rating Per All 120 CONTACT YOUR BALDOR REPRESENTATIVE CONTACT YOUR BALDOR REPRESENTATIVE Index Baldor District Offices 332

333 Modification Mod Express Description and Mod Express Working Days Required Soft Starters & Dynamic Brakes M4 M4A Conduit Box Tap or Provide Additional Lead Hole Lead outlet hole in conduit box with dimensions as shown below will be tapped to accept threaded conduit as shown in Optional threaded hole... column below. An additional clearance hole or threaded hole may be supplied if specified. Use same list adder for threaded hole. Hole Diameter * Stock For Conduit Size Optional Threaded Hole For Conduit Size Per Oversize Box Per T 7/8 1/2 3/ T 1-1/16 3/ T T 1-3/ / T T 2 1-1/ T T 2-1/ / T 3 2 1/ T 3 2-1/ NOTE: * Stock motor lead holes are not threaded except on Dirty Duty and Chemical Process motors. Extra lead holes do not apply to Explosion Proof motors. If additional hole is needed, specify hole diameter and exact location. Contact your Baldor representative for application assistance. TWO DAYS Gearmotors and Gear Products Accessories Grinders Generators M4B M4C Rotate Conduit Box Lead Opening Specify lead opening location facing conduit box Per : $96 Add Oversized Cast Iron Conduit Box 2100 Cubic Inches Per 449T 195 NOTE: Consider use of IEEE 841 motors that have oversized conduit boxes standard. TWO DAYS TWO DAYS Mod Express Baldor Education Workshops Index M4E Add 3.5" Round Accessory Box 12 Cubic Inches - for Thermostat, Heater or accessory leads. NOTE: Perform in Charlotte. Contact Baldor for time. Per 5007L L 356 -CONTACT YOUR BALDOR REPRESENTATIVE Baldor District Offices 333

334 Soft Start & Dynamic Brakes Modification Mod Express Description and Mod Express Working Days Required Gearmotors and Gear Products Accessories M4 M4F Conduit Box continued... Replace Die Cast Aluminum Conduit Box Install cast iron conduit box with drilled and tapped entrance hole. Per T T T 183 TWO DAYS Grinders Generators Mod Express Baldor Education Workshops M5 M5A Cord Wire Gauge Install Line Cord in Conduit Box or Terminal Panel Heavy duty, industrial type SO oil resistant cord with ground will be installed in conduit box or terminal panel. Strain relief included. Plug not included. Does Not Apply to Explosion-Proof 1φ Amp Rating NOTE: Specify voltage and rotation facing drive end of motor. 3φ Six Feet or Less Each Additional Foot to Ten Max TWO DAYS Index Baldor District Offices M5B Install 6 Foot, 3 Conductor, Type SO Cord With Plug With ground plug for 115VAC, single phase only. Not for explosion proof motors. Per 1 and smaller 93 NOTE: Advise rotation facing drive end of motor TWO DAYS 334

335 Modification Mod Express Description and Mod Express Working Days Required Soft Starters & Dynamic Brakes M6 M6A Switch Install Switch, Cord and Plug (Single Phase Only) Includes installation of cord with ground prong and two pole single throw switch. Does Not Apply to Explosion-Proof Rating per Thru A/115V or 230V 197 NOTE: Advise voltage and rotation facing drive end of motor TWO DAYS Gearmotors and Gear Products Accessories M6C Change from Mechanical to Electronic (Single Phase Only) UP to 2 HP (Includes price of switch). Remove mechanical switch from inside motor and install electronic switch in motor conduit box. Contact Baldor for assistance. Each: $206 Does Not Apply to Explosion-Proof TWO DAYS Grinders Generators M7 M7A DRAINS Add Condensation Drain Holes A maximum of two additional drilled holes will be made in both endplates of 215T frame and smaller TEFC motors. A maximum of one additional cross-drilled drain fitting will be installed in both endplates of 254T frame and larger TEFC motors. Does Not Apply to Explosion-Proof TWO DAYS Mod Express Baldor Education Workshops Per 215T and Smaller T - 447T T L 491 Index NOTE: Indicate position of drain holes in each endplate. M7B Install T Drain Install one stainless steel T drain in each end bracket in existing hole. Does Not Apply to Explosion-Proof TWO DAYS Baldor District Offices Per 254T L

336 Soft Start & Dynamic Brakes Modification Mod Express Description and Mod Express Working Days Required Gearmotors and Gear Products Accessories M7 M7C Drains continued... Close Standard Condensation Drain Holes. Close existing drain holes with plugs. Does Not Apply to Explosion-Proof Per 215T and Smaller T L 146 TWO DAYS Grinders Generators Mod Express Baldor Education Workshops Index Baldor District Offices M8 M7D Dripcovers Add Breather Drains to Cast Iron Explosion-Proof. Per T T 298 TWO DAYS M8A Install Dripcover on TEFC or ODP TWO DAYS Per ODP or TEFC T T T T T T T T (Nema )

337 Modification Mod Express Description and Mod Express Working Days Required Soft Starters & Dynamic Brakes M9 M9A Encapsulation Encapsulate Winding Endturns for Additional Environmental Protection. Endturns are coated with Dolphon CB-1128, flexible motor encapsulation component. Per T T T T T T T T T T L ( has VPI epoxy varnish ENCAP NOT NEEDED) TWO DAYS Gearmotors and Gear Products Accessories Grinders Generators M10 M10A Leads Install Terminal Lugs Specify type of lug. Subject to availability Per 215T and Smaller T T T L 165 TWO DAYS Mod Express Baldor Education Workshops M10B Reconnect from Nine Leads to Three, Specify Voltage When Ordering TWO DAYS Index Per T T T T T T 413 Baldor District Offices NOTE: On explosion proof, leads are connected in conduit box. 337

338 Soft Start & Dynamic Brakes Modification Mod Express Description and Mod Express Working Days Required Gearmotors and Gear Products Accessories Grinders Generators Mod Express Baldor Education Workshops Index Baldor District Offices M10 M11 M10C M10D M11A Leads continued Lubrication Re-Mark Leads Using Cloth Markers - Specify Markings, Letters or s Any Size - Per : $105 Longer Leads, Total Length Up To: Install Low Temperature Lubricant in Bearings Bearing grease may be changed to allow an operating temperature range for bearings of -55 to +200 F. Standard grease is Exxon POLYREX EM, with bearing operating temperature range of -15 to +250 F. NOTE: Single shield or open bearing only. Low temperature operation below -25C(-13F) Does Not Apply to Explosion-Proof 18 Inches 24 Inches 36 Inches T T T Does Not Apply to Explosion-Proof Per T T T T T T T T T 464 TWO DAYS TWO DAYS TWO DAYS 338

339 Modification Mod Express Description and Mod Express Working Days Required Soft Starters & Dynamic Brakes M11 M11B Lubrication continued... Add High Temperature or Customer Supplied Grease Bearing grease may be changed to allow an operating temperature range above the standard grease, which is Exxon POLYREX EM, with bearing operating temperature range of -15 to +250 F. must be studied by Fort Smith application engineering for acceptable temperature rise above 40 C ambient. Customer-supplied grease must be suitable for the motor application and approved by Fort Smith application engineering. Grease must be accompanied with MSDS data sheets. Does Not Apply to Explosion-Proof Per T T T T T T T T T 464 NOTE: Contact your Baldor representative to discuss application prior to ordering. TWO DAYS Gearmotors and Gear Products Accessories Grinders Generators Mod Express M12 Seals M12A Install Oil Seals CONTACT Each T - 145T T - 184T T - 215T T - 256T T - 286T T - 326T T - 365T 634 NOTE: Contact your Baldor representative for larger frame sizes. Does Not Apply to Explosion-Proof YOUR BALDOR REPRESENTATIVE Baldor Education Workshops Index Baldor District Offices 339

340 Soft Start & Dynamic Brakes Modification Mod Express Description and Mod Express Working Days Required Gearmotors and Gear Products Accessories Grinders Generators Mod Express Baldor Education Workshops M12 M13 M12B M13A Seals continued... Mountings NOTE: Not available for cast iron motors. Install Inpro/Seal Drive End Only Contact Baldor for Other Sizes. NOTE: Contact Baldor for opposite drive end installation. Does Not Apply to Explosion-Proof Each 143T-215T T T T T T T L L 1741 Add Rigid Base Weld stamped steel base to steel band motors. Not available if conversion results in motors that fall under EPAct requirements. Per T T T 165 FOUR DAYS TWO DAYS Index Baldor District Offices M13B Install C-Face Steel Band Construction Add to rigid base mounted motor. Not for explosion proof motors. Per 42, 48 & T (1) T (1) T (1) T (2) T (2) T (2) 655 TWO DAYS 284T & LARGER SUBJECT TO CASTING AVAILABILITY NOTE: (1) These motors will have a non- BA dimension when C-Face is added. (2) Applies to ODP only. Open motors having type numbers beginning with 34 cannot be modified to C-Face. Contact your Baldor representative for details. 340

341 Modification Mod Express Description and Mod Express Working Days Required Soft Starters & Dynamic Brakes M13 Mountings continued... M13C Install C-Face - Cast Iron Construction Or Install Cast Iron Endplate where aluminum die cast parts are supplied as standard. Does Not Apply to Explosion-Proof TWO DAYS Gearmotors and Gear Products NOTE: (1) These motors will have a non- BA dimension when C-Face is added. Specify C-face or Standard horizontal endplate. (2) have Cast Iron endplates as standard. Westville open motors cannot be modified to C-Face. IEEE841 motors cannot be modified to C-Face. Contact Baldor. M13D Baldor Type M13E Add D-Flange Some motors may be converted to D-Flange mounting. Contact your Baldor representative for availability and pricing. NOTE: Some metric flanges are available. Contact your Baldor representative. Does Not Apply to Explosion-Proof NOTE: Bases cannot be removed from explosion proof motors. Addition Each End C-Face Endplate 48 & T (1) T (1) T (1) T 475 (2) T 655 (2) T 709 (2) T 764 (2) T 955 (2) T 1146 (2) T 1146 (2) Open TEFC Remove Rigid Base From Foot Mounted Steel Band. Per T 35EP1604A01 35EP1506A T 36EP1405A09 36EP1304A T None 36EP1304A U, T None 09EP1500A04 ** U, T None 10EP1502A U, T 42EP1601A01 None U, T None 12EP1501A U, T 14EP1601AA01 14EP1705A U, T 16EP1601A01 16EP1501A U, T 18EP1600A01 18EP1500A NOTE: ** Must start with motor that already has C-Face on it +++ These require a special machined D-flange, available only through Mod Express Per Per T T T T T T 487 CONTACT YOUR BALDOR REPRESENTATIVE TWO DAYS Accessories Grinders Generators Mod Express Baldor Education Workshops Index Baldor District Offices 341

342 Soft Start & Dynamic Brakes Modification Mod Express Description and Mod Express Working Days Required Gearmotors and Gear Products Accessories Grinders Generators Mod Express Baldor Education Workshops M13 M13F Mountings continued... Convert to F-2, Sidewall, or Ceiling Mount AC motors and DC motors through 10 Consists of repositioning endplate vents, condensation drains, and where applicable, the conduit box to positions shown in chart on page 344. NOTE: Specify mounting style from the drawings on page 344. Open slotted band motors are not convertible to C or W mountings. 09 or larger with 12 o clock location requires 3 days lead time. Charlotte DC motors would be converted at the Charlotte plant. Contact scheduling to check availability of production motors or to ship motor from Fort Smith for conversion. Contact your Baldor representative. M13G Does Not Apply to Explosion-Proof Add C-Face to Explosion Proof Only available on frames shown below. THREE DAYS C1 C2 W4 W5 W3 W8 F2 W1 W2 W7 W6 Per Enclosure ODP TEFC ODP TEFC ODP TEFC ODP TEFC ODP TEFC UP TO 184T Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes T Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes T No Yes No Yes Yes Yes No Yes Yes Yes T - 447T Yes Yes No Yes Yes Yes No Yes Yes Yes T L Yes Yes Yes Yes Yes 681 Per T T T T T 2318 NOTE: Any other frame size must be built as a custom item. THREE DAYS Index Baldor District Offices M13H Mount Dust Control Unit on Grinders TWO Wheel Size Per All 113 DAYS 342

343 Modification Mod Express Description and Mod Express Working Days Required Soft Starters & Dynamic Brakes M13 M13I Mountings continued Mount Grinder or Buffer onto a Pedestal and Package for Shipment Wheel Size Per Grinder or Buffer All 113 TWO DAYS Gearmotors and Gear Products Accessories M13J ADD ADJUSTABLE MOTOR BASES Adjustable motor bases bolted to fixed base on stock motor before shipping. 215T and smaller bases feature one adjusting screw. Bases on 254T frame and larger feature two adjusting screws. Per T - 145T T - 184T T - 215T T - 256T T - 286T T - 326T T - 365T T - 405T T - 445T T - 449T 884 NOTE: Bases not suitable for vertical mounting. TWO DAYS Grinders Generators Mod Express Baldor Education Workshops Baldor District Offices Index 343

344 Soft Start & Dynamic Brakes Mod Express Mounting Configurations Mod Express Gearmotors and Gear Products Floor Mountings Accessories Assembly F-1 Assembly F-2 Assembly F-3 Grinders Generators Mod Express Baldor Education Workshops Wall Mountings Assembly W-1 Assembly W-2 Assembly W-3 Assembly W-4 Assembly W-5 Assembly W-6 Assembly W-7 Assembly W-8 Index Baldor District Offices Ceiling Mountings Assembly C-1 Assembly C-2 344

345 Modification Mod Express Description and Mod Express Working Days Required Soft Starters & Dynamic Brakes M14 M14A Export Packaging Box, Package and Crate For under-deck exporting FOUR DAYS Gearmotors and Gear Products Each T T T L 2551 Accessories M15 Nameplate Grinders M15A Provide Auxiliary Data Plate for Remote Mounting Extra nameplate is packed with motor, not mounted. Per : $80 TWO DAYS Generators M15B Replace/Add Customer Nameplate Add Customer Part and/or other changes such as voltage, hertz, etc. Per : $96 TWO DAYS Mod Express M15C Replace with Stainless Steel Nameplate Per $96 TWO DAYS Baldor Education Workshops M15D Add Bearing Data Nameplate Per $96 NOTE: Does Not Apply to Explosion-Proof TWO DAYS Index M15E Mail Out Nameplates to District Offices (All CSA and ULR markings are removed on nameplates ordered as a mail out order) No Explosion Proof Nameplates (No Exceptions!) Order minimum charge of $18 Add $1 for each additional nameplate. NOTE: No charge orders only accepted if we are correcting our error. Nameplates for Explosion-proof motors will not be mailed out, no exceptions. Baldor District Offices 345

346 Soft Start & Dynamic Brakes Modification Mod Express Description and Mod Express Working Days Required Gearmotors and Gear Products M16 M16A Blowers Add Constant Velocity Blower Unit Contact Baldor for details. TWO DAYS Accessories M16B Convert from a 3 Phase to a Single Phase Blower TWO DAYS Grinders Generators Mod Express Baldor Education Workshops M17 M17A Paint Per All 150 Paint to Baldor Stock Paint Color Baldor stock colors are: Dark Machinery Gray, Fire Engine Red, Vista Green, Medium Royal Blue, Silver/Grey Hamertone and Copper/Bronze. All are lacquer base. All orders that call for Epoxy Paint require an additional day to allow for comlete drying of paint. Per T T T L 764 TWO DAYS Index Baldor District Offices M17B Paint to Customer Color Contact your Baldor representative for color match, availability and price. NOTE: Specifying epoxy paint will add one additional day to allow for complete drying of paint. THREE DAYS (From Date Paint is Available in Fort Smith) 346

347 Modification Mod Express Description and Mod Express Working Days Required Soft Starters & Dynamic Brakes M18 M18A Lifting Lugs Add Lifting Lugs Up to a 326T Size Per T T T T 285 TWO DAYS Baldor District Offices Gearmotors and Gear Products Grinders Accessories M19 Screens M19A Add Rodent Screens to Open Drip-Proof Per TWO DAYS Generators T T - 405T 251 Mod Express M20 M20A Baldor Education Workshops Index Hardware Exchange Plated Hardware with Stainless Steel Per 145T - 215T T - 326T T - 405T T TWO DAYS 347

348 Soft Start & Dynamic Brakes Modification Mod Express Description and Mod Express Working Days Required Gearmotors and Gear Products Accessories Grinders Generators Mod Express Baldor Education Workshops Index Baldor District Offices M21 M22 M21A Space Heaters Add Space Heaters to TEFC or Open Standard space heater voltage is 110VAC. Heaters for 230 or 460 volts are available. Specify circuit voltage. NOTE: Strip type space heaters are standard frame perform in Charlotte. Contact Baldor for time. Does Not Apply to Explosion-Proof M21B Add Conduit Box for Thermostat or Heater Leads (See M4E) Not for explosion proof motors. NOTE: Perform in Charlotte. Contact Baldor for time and freight charges to ship motor to Charlotte plant. M22A Textile Service Per 145T and Smaller T T T T L 817 Up to 5011L 356 Lint Proof Fan Cover for Textile Applications Remove standard fan cover and replace with textile fan shroud and cover. Per T T T T T T T T T 735 TWO DAYS CONTACT YOUR BALDOR REPRESENTATIVE TWO DAYS 348

349 Modification Mod Express Description and Mod Express Working Days Required Soft Starters & Dynamic Brakes M23 M23A Thermal Protectors Thermostats One or More Thermostats Laced to Winding For over temperature protection. These are pilot circuit devices only with leads into conduit box tagged JJ. Specify normally open or closed contacts. of Devices NOTE: (3) In Series with two leads into conduit box. Normally open are in parallel. Does Not Apply to Explosion-Proof Per Single Phase Three Phase T 3 (3) 137 Three Phase T 3 (3) 369 Direct Current T TWO DAYS Gearmotors and Gear Products Accessories Grinders M23B Exchange Thermal Overload Exchange from manual thermal overload to automatic thermal overload or exchange from automatic thermal overload to manual thermal overload. TWO DAYS Generators Per M.T.O to A.T.O. OR A.T.O. to M.T.O. 48 and and 145T T T 246 Mod Express Does Not Apply to Explosion-Proof M23C Install Resistance Temperature Detectors Install on low voltage winding endturns (Six 100 OHM RTD s). Per 449T L 2722 NOTE: 449T - up perform in Charlotte. Contact Baldor for time and freight to ship motor to Charlotte plant. CONTACT YOUR BALDOR REPRESENTATIVE Baldor Education Workshops Index Does Not Apply to Explosion-Proof Baldor District Offices 349

350 Soft Start & Dynamic Brakes Modification Mod Express Description and Mod Express Working Days Required Gearmotors and Gear Products Accessories Grinders Generators Mod Express Baldor Education Workshops M24 M25 M24A M25A M25B Winding Thermocouples (3 per motor, 6 foot standard length) Iron Constantan (3 per motor) Specify location. Winding Thermistors One or Two : $224 Three Per : $469 Per Thermocouple T T L 1634 NOTE: 5000 frame perform in Charlotte. Contact Baldor for time and freight to ship motor to Charlotte plant. Does Not Apply to Explosion-Proof NOTE: 5000 frame perform in Charlotte. Contact Baldor for time and freight to ship motor to Charlotte plant. Does Not Apply to Explosion-Proof TWO DAYS TWO DAYS TWO DAYS Index Baldor District Offices 350

351 Modification Mod Express Description and Mod Express Working Days Required Soft Starters & Dynamic Brakes M26 M26A Tropicalization Protection of Windings and Mechanical Parts Protection from tropical environments. Per AC DC Through 215T T T 396 N/A TWO DAYS Gearmotors and Gear Products Accessories M27 Weatherproofing Grinders M27A Treatment of Windings and Mechanical Parts Protection from the elements or high moisture areas. Per AC DC Through 215T T 231 (4) T 396 (4) N/A NOTE: (4) Baldor Dirty Duty, CP and ECP motors are weatherproofed as standard. Does Not Apply to Explosion-Proof TWO DAYS Generators Mod Express M28 Marine M28A IEEE 45 A combination of M4A and M27 for frames 215T and smaller plus nameplate stamped IEEE 45. frames 254T and larger require tapping of conduit box and nameplate stamped IEEE 45. Per AC DC 42, 48, T T 268 N/A T 396 N/A TWO DAYS Baldor Education Workshops Index Baldor District Offices 351

352 Soft Start & Dynamic Brakes Modification Mod Express Description and Mod Express Working Days Required Gearmotors and Gear Products Accessories M29 Shaft Modifications Includes modifications to existing shafts only. Not applicable if new shaft is required. each modification per table M29 or M29D. NOTE: (5) Arbor Saw. Per Modification Per Modification T T - 256T T T 260 ASM62 (5) T T T 415 ASM75 (5) T 469 FIVE DAYS Grinders Generators Mod Express Baldor Education Workshops Index Baldor District Offices M29A M29B M29C M29D Shaft Drill and Tap One Hole in End of Shaft or Mill Flat on Shaft Extension. Provide details on order. this modification per table M29. Convert from TEFC to TEAO Cut off shaft extension for external fan. this modification per table M29. Does Not Apply to Explosion-Proof Threading Specify right hand or left hand thread, also type and length of thread. this modification per table M29. Convert T to U Shaft Dimension or Smaller (TS) Provide details on order. Conversion of T to TS or U Work Days Required Per 143 thru 145T 5 Days thru 215T 5 Days thru 286T 5 Days thru 365T 5 Days thru 449T 5 Days 1493 THREE DAYS THREE DAYS FIVE DAYS FIVE DAYS 352

353 Modification Mod Express Description and Mod Express Working Days Required Soft Starters & Dynamic Brakes M29 M29E Shaft Modifications continued... Shaft Grounding Brush Shaft Grounding Systems Add Shaft Grounding System unit to opposite shaft end of motor on TEFC, TENV, TEBC and ODP motors. Available for all frame sizes. Shaft grounding brush provides a current path from the rotor to the frame to lessen the chance of bearing fluting. Insolated bearings isolate the shaft, but rotor currents can be passed through a conductive coupling to the driven load and damage bearings there. Standard on stocked 449T-up Vector Drive motors. Baldor Type Addition / TWO DAYS Gearmotors and Gear Products Accessories Grinders Does Not Apply to Explosion-Proof M29F Shorten Shafts Without Reducing the Overall Diameter THREE DAYS Generators Shaft Per T T T T 456 Mod Express Baldor Education Workshops M29G M29H M29I Special Shafts Contact Baldor for price and availability. Convert to a Longer Shaft Up to a 215T Contact Baldor for price and availability. Index Baldor District Offices Machine Explosion Proof Shafts from T to U Contact Baldor for price and availability. 353

354 Soft Start & Dynamic Brakes Modification Mod Express Description and Mod Express Working Days Required Gearmotors and Gear Products Accessories M30 M30A Grounding Screw Add Grounding Screw On Endplate Requirement for UL 1081, swimming pool pump motors (includes slinger.) : $88 TWO DAYS M31 Tach Mounting Kits Grinders Generators Mod Express Baldor Education Workshops M31A NOTE: includes tach kit. M31B Add Tach Mounting Kits Only Tach mounting kits are listed on page These kits are complete and will allow mounting of a BTG1000 or XPY tach generator (tach generator not included). Baldor Type Per 3300P D/P D/P D/P D D Tach Kit with BTG1000 Tach Order tach kit per M31A and order tach separately. THREE DAYS FOUR DAYS Index Baldor District Offices M31C M31D Tach Kit with XPY Tach Order tach kit per M31A and order tach separately. Add Encoder Kit to Inverter Duty Order encoders separately. Encoders are listed on page 167. Per FOUR DAYS TWO DAYS T T-404T T-5009L

355 Modification Mod Express Description and Mod Express Working Days Required Soft Starters & Dynamic Brakes M32 Testing M32A CSA C390 Method 1 Equivalent to IEEE 112 Method B Performance Testing Three phase stock motors will be tested under lab conditions according to CSA C390 (equivalent to IEEE 112b). Complete test data will be supplied. Per T T - 447T T L 5842 SEVEN DAYS Gearmotors and Gear Products Accessories Grinders M32B Witnessed CSA C390 Method 1 Equivalent to IEEE 112 Method B Performance Testing Test schedule must be coordinated with Baldor corporate office. Per T T - 447T T L 9030 SEVEN DAYS Generators Mod Express M33 M33A Short Test Performance - Short Test Three phase or single phase motors will have any or all of the following motor characteristics measured. Test data will be supplied. All data will be taken on cold motor. No Current Current Breakdown Torque Locked Rotor (Starting) Current Locked Rotor Torque Hi-Potential Test Per T T 399 SEVEN DAYS Baldor Education Workshops Index Baldor District Offices 355

356 Soft Start & Dynamic Brakes Modification Mod Express Description and Mod Express Working Days Required Gearmotors and Gear Products Accessories Grinders Generators Mod Express Baldor Education Workshops M34 M34A Size M34B Worm Gear Modifications Horiz. Base Install Bases on Worm Gear Speed Reducers. price include bases. 900 Series Universal Series Vertical Vertical Vertical Base Low Base High Base Size (Converts STF to SVF) Convert from Single to Double End Output Shaft on Worm Gear Speed Reducers. price includes shaft. 900 Series Universal Series Size Size TWO DAYS TWO DAYS Index Baldor District Offices M34C M34D Convert Output Shaft from Left Hand to Right Hand or vice versa on 900 or Universal Series Reducers $110 ( does not include reducer) Install on 900 F-Series or Universal STF Series Reducers $110 ( does not include motor or reducer) TWO DAYS TWO DAYS 356

357 Modification Mod Express Description and Mod Express Working Days Required Soft Starters & Dynamic Brakes M35 M35A Terminal Blocks Install IEC Terminal Blocks in Conduit Box and Connect Leads IEC, stocked with terminal blocks. Advise how motors leads are to be connected. Does Not Apply to Explosion-Proof 34 FRAME T FRAME T TWO DAYS Gearmotors and Gear Products Accessories Grinders Generators M36 M36A Starters Add Magnetic or Manual Starter to Grinder or Buffer Mounted and wired on Baldor industrial grinders and buffers. Starters are in 1 enclosure and have the push button in cover. Available only as factory installed options. Lead time is dependant on delivery of the starter. Starter Single Phase voltage control. Grinder Buffer Manual Magnetic Wheel 115/230 Volts 115 Volts 230 Volts Size 6" 1/ N/A 7" N/A " 3/ " N/A 1-1/ " 2 Standard Equipment NOTE: Specify voltage when ordering. * includes allowance for omission of standard starter. TWO DAYS Mod Express Baldor Education Workshops Index Baldor District Offices 357

358 Soft Start & Dynamic Brakes Modification Mod Express Description and Mod Express Working Days Required Gearmotors and Gear Products Accessories Grinders Generators Mod Express Baldor Education Workshops Index Baldor District Offices M36 M37 M36B M36C M36D Starters continued... NOTE: Must be used with magnetic control. Contact Baldor for details. M37A Voltage Starter Three Phase voltage control. Grinder Buffer Manual Magnetic Wheel /460 Volts Volts 460 Volts Size 7" N/A " N/A " 3/ " 1 Standard Equipment " 2 Standard Equipment NOTE: Specify voltage when ordering. * includes allowance for omission of standard starter. Grinder Wheel Size Magnetic Starter Three Phase With Low Voltage Control. Buffer NOTE: Specify voltage when ordering. * includes allowance for omission of standard starter. Magnetic With 110 Volt Control Circuit Transformer Volts 460 Volts 7" N/A " N/A " 3/ " " " " 7-1/ Overload Protection for Dust Control Unit All 410 Change a Grinder Dust Control Unit from 230/460 Volts to 575 Volts TWO DAYS TWO DAYS TWO DAYS TWO DAYS All

359 Modification Mod Express Description and Mod Express Working Days Required Soft Starters & Dynamic Brakes M38 M38A Receptacles Meltric Receptacles Many customers are requesting that motors are shipped to them with quickconnect receptacles that interface with new industrial modular wiring systems. Meltric Corporation and Brad Power design the two most popular systems. These systems do not interchange with each other. Baldor plans to supply the receptacle pre-mounted and wired to the motor conduit box. The customer may purchase other components required for the modular wiring system at a local electrical supply distributor. Note: not for use on explosion proof motors. DSN60 DB60 Gearmotors and Gear Products Accessories Grinders Voltage Maximum HP Meltric Connector Device Inlet with Straight Adapter NOTE: 2P = 2 power leads (single phase) 3P = 3 power leads (three phase) E = Earth ground Addition 120VAC (1P+N+E).5 DSN S-T VAC (1P+N+E) 1 DSN S-T VAC (1P+N+E) 2 DSN S-T VAC (1P+N+E) 3 DB S-T VAC (1P+N+E) 7.5 DB S-T VAC (2P+E) 1 DSN S-T VAC (2P+E) 3 DSN S-T VAC (2P+E) 3 DSN S-T VAC (2P+E) 7.5 DB S-T VAC (2P+E) 10 DB S-T VAC (3P+E) 2 DSN S-T VAC (3P+E) 5 DSN S-T VAC (3P+E) 7.5 DSN S-T VAC (3P+E) 15 DB S-T VAC (3P+E) 30 DB S-T VAC (3P+E) 2 DSN S-T VAC (3P+E) 5 DSN S-T VAC (3P+E) 7.5 DSN S-T VAC (3P+E) 15 DB S-T VAC (3P+E) 30 DB S-T VAC (3P+E) 15 DSN S-T VAC (3P+E) 20 DSN S-T VAC (3P+E) 25 DS S-T VAC (3P+E) 30 DB S-T VAC (3P+E) 60 DB S-T Receptacle fastens to straight adapter that is mounted on conduit box. Smaller types with square conduit boxes may have the adapter fastened to the CB cover. Cast iron motors may need the adapter mounted to the lead outlet side on the conduit box. Receptacles with two additional connections for auxiliary devices are also available at a slightly higher cost. Generators Mod Express Baldor Education Workshops Index Baldor District Offices Baldor does not supply the mating connectors. The receptacles are available mounted to our motors as a convenience to customers wanting motors ready for installation at their facility. 359

PRODUCT OVERVIEW. Baldor s mission is to be the best (as determined by our customers) marketers, designers and manufacturers

PRODUCT OVERVIEW. Baldor s mission is to be the best (as determined by our customers) marketers, designers and manufacturers PRODUCT OVERVIEW Baldor s mission is to be the best (as determined by our customers) marketers, designers and manufacturers Motors General Purpose TEFC 1/12 Hp thru 600 Hp stock, to 800 Hp custom Enclosures:

More information

Instruction Manual For Baldor Buffers

Instruction Manual For Baldor Buffers No. 280F Replaces 280E LB7011 Instruction Manual For Baldor Buffers SAFETY NOTICE: WARNING statements describe conditions that may lead to personnel injury including potentially fatal injuries if the machine

More information

Definite Purpose Motors. Three Phase, Two Speed, TEFC, Foot Mounted. Applications: Fans, blowers, machine tools, hoists, conveyors, pumps.

Definite Purpose Motors. Three Phase, Two Speed, TEFC, Foot Mounted. Applications: Fans, blowers, machine tools, hoists, conveyors, pumps. Three Phase, Two Speed, TEFC, 1 thru 25 56 thru 324T Applications: Fans, blowers, machine tools, hoists, conveyors, pumps. Features: Lifting eye bolt mounted at top center 215T frame and larger for easy

More information

Definite Purpose Motors. Three Phase, Two Speed, TEFC, Foot Mounted. 3/4 thru 25 Hp NEMA 56 thru 324T

Definite Purpose Motors. Three Phase, Two Speed, TEFC, Foot Mounted. 3/4 thru 25 Hp NEMA 56 thru 324T Unit Handling Brake 200 & 575 Volt IEC & Controls DC 158 Two Speed, TEFC, Cast Iron 3/4 thru 25 56 thru 324T Applications: Fans, blowers, machine tools, hoists, conveyors, pumps. Features: Designed for

More information

Baldor-Reliance CA501 Standard motor product catalog

Baldor-Reliance CA501 Standard motor product catalog Baldor-Reliance CA501 Standard motor product catalog CA501 effective July 1, 2018 Table of contents General information 5 notes 6 Approvals UL and CSA 7 Motors used outside of the United States 8 UL and

More information

Stock Product Quick Reference Guide

Stock Product Quick Reference Guide Stock Product Quick Reference Guide A Regal Brand Thousands of solutions. One matched perfectly to your needs. More than 6,000 stock motors, gearmotors, gear reducers and control designs available. Yes,

More information

MN907 No. 285B Replaces 285A LB7012

MN907 No. 285B Replaces 285A LB7012 MN907 No. 285B Replaces 285A LB7012 Instruction Manual For Baldor Grinder--Buffers SAFETY NOTICE: WARNING statements describe conditions that may lead to personnel injury including potentially fatal injuries

More information

Warranty Policy No-Fault Warranty (excludes Washdown motors)

Warranty Policy No-Fault Warranty (excludes Washdown motors) Warranty Policy No-Fault Warranty (excludes Washdown motors) Motors with frame sizes 215T and smaller are covered under a No-Fault warranty. This warranty claim is offered one time, per end-user, per application.

More information

Single and Three Phase General Purpose Motors

Single and Three Phase General Purpose Motors Single and Three Phase Single phase and three phase general purpose motors are designed to meet or exceed the energy efficiency requirements of the United States, Canada and Mexico for general purpose

More information

SHADED RATINGS ARE CAST IRON FRAMES

SHADED RATINGS ARE CAST IRON FRAMES Gearmotors and NEMA AC C-Face Kits for Field Conversion Features: Complete kits with all hardware necessary for converting 56 through 445T frame rigid base motors to C-Face mounting with base. For a conversion,

More information

DC Motors & Controls for many different applications

DC Motors & Controls for many different applications DC Motors & Controls for many different applications Baldor offers the widest variety of DC Motors. From 1/50 to 3000 horsepower, our rugged industrial designs may be used to power everything from a medical

More information

Inverter Speed Ratio Information

Inverter Speed Ratio Information Inverter Speed Ratio Information Guidelines for Application of General Purpose,, Single Speed on Variable Frequency Drives Meets NEMA MG1-2006 Part 30 and Part 31 Section 4.4.2 Unless stated otherwise,

More information

Your Source for a Complete Line of Electric Motors. Rolled Steel Motors. A Complete Line of Single Phase and Three Phase Rolled Steel Motors

Your Source for a Complete Line of Electric Motors. Rolled Steel Motors. A Complete Line of Single Phase and Three Phase Rolled Steel Motors Your Source for a Complete Line of Electric Motors Rolled Steel Motors A Complete Line of Single Phase and Three Phase Rolled Steel Motors Mission Statement To provide the United States market for industrial

More information

Motor Accessories. NEMA AC Motor C-Face Kits for Field Conversion

Motor Accessories. NEMA AC Motor C-Face Kits for Field Conversion Gearmotors and PT Components Grinders Gearmotors Servo s Mod Express Baldor Education Workshop 396 NEMA AC C-Face Kits for Field Conversion Description Type/ NOTE: NEMA BA Dimension will be non-standard

More information

Instruction Manual For Baldor Tool Grinders

Instruction Manual For Baldor Tool Grinders No. 281H Replaces 281G LB7010 Instruction Manual For Baldor Tool Grinders SAFETY NOTICE: WARNING statements describe conditions that may lead to personnel injury including potentially fatal injuries if

More information

Pump Motors. Information. General. Single Phase Motors. Industrial Motors. General Purpose. Severe Duty Motors

Pump Motors. Information. General. Single Phase Motors. Industrial Motors. General Purpose. Severe Duty Motors General Industrial Pump HVAC Farm Duty 8 Pump From industrial wastewater to fire suppression systems or commercial pools, Baldor Reliance pump motors provide value by increasing reliability and reducing

More information

1/ Horsepower Product Line DPG-FV, TEFC, TENV, XP, SPG enclosures Fractional DC DC PM SCR Round RPM III

1/ Horsepower Product Line DPG-FV, TEFC, TENV, XP, SPG enclosures Fractional DC DC PM SCR Round RPM III DC & Controls Available in round frame and unique laminated square frames, Reliance DC motors offer performance and reliability in tough applications. Round frame DC motors utilize permanent magnet technology

More information

Over 525 Stock Motor Ratings. The Right Pump Motor for your Application. Leadership in Premium Efficiency. 1

Over 525 Stock Motor Ratings. The Right Pump Motor for your Application. Leadership in Premium Efficiency.   1 Baldor Pump Motors Baldor Reliance is the leading supplier of Pump Motors to meet industrial and commercial applications. From industrial waste water to commercial pool pump motors Baldor Reliance pump

More information

NEMA AC Motor C-Face Kits for Field Conversion

NEMA AC Motor C-Face Kits for Field Conversion Gear s NEMA AC C-Face Kits for Field Conversion Features: Complete kits with all hardware necessary for converting Baldor 56 through 445T frame rigid base motors to C-Face mounting with base. For a Baldor

More information

Industrial and Commercial Duty IEC Motors

Industrial and Commercial Duty IEC Motors Industrial and Commercial Duty IEC Motors A Regal Brand Five product families delivering a world of opportunity LEESON Passport Series IEC Motors. There s a world of opportunity right here at home. The

More information

Variable Speed Motor Products

Variable Speed Motor Products Variable Motor Products Why Baldor? Customer Preference 90% 2000 20% 1985 50% 1990 Percentage of research studies in which Baldor was chosen most preferred. For nearly 100 years, Baldor has strived to

More information

SECTION MOTOR REQUIREMENTS for HVAC

SECTION MOTOR REQUIREMENTS for HVAC PART 1 GENERAL 1.1 SECTION INCLUDES A. Single-phase electric motors B. Three-phase electric motors 1.2 REFERENCES SECTION 23 05 13 MOTOR REQUIREMENTS for HVAC A. ABMA 9 - Load Ratings and Fatigue Life

More information

DC Motors & Controls. Subfractional Permanent Magnet DC Motor - TENV, Rigid Base. SCR Drive Permanent Magnet Motor - TENV and TEFC, C-Face with Base

DC Motors & Controls. Subfractional Permanent Magnet DC Motor - TENV, Rigid Base. SCR Drive Permanent Magnet Motor - TENV and TEFC, C-Face with Base Subfractional Permanent Magnet DC Motor - TENV, Rigid Base 1/50 thru 1/4 Hp DC & Controls Applications: General purpose including conveyors, material handling equipment and packaging machinery. HVAC Features:

More information

Shaft Mount Reducers

Shaft Mount Reducers Your Source for a Complete Line of Electric Motors & Gearing Shaft Mount Reducers & Accessories Mission Statement To provide the United States market with industrial motors, controls and gearing products

More information

DC Motors & Controls. Subfractional Permanent Magnet DC Motor - TENV, Rigid Base. SCR Drive Permanent Magnet Motor - TENV and TEFC, C-Face with Base

DC Motors & Controls. Subfractional Permanent Magnet DC Motor - TENV, Rigid Base. SCR Drive Permanent Magnet Motor - TENV and TEFC, C-Face with Base Subfractional Permanent Magnet DC Motor - TENV, Rigid Base 1/50 thru 1/4 DC & Controls Applications: General purpose including conveyors, material handling equipment and packaging machinery. Features:

More information

1/50 thru 1/4 Hp. Catalog Number. Applications: Conveyors, mixers, packaging machinery. Enclosure

1/50 thru 1/4 Hp. Catalog Number. Applications: Conveyors, mixers, packaging machinery. Enclosure Subfractional Permanent Magnet DC Motor - TENV, Rigid Base 1/50 thru 1/4 Hp DC & Controls Applications: General purpose including conveyors, material handling equipment and packaging machinery. HVAC Features:

More information

Applications: Pumps, fans, compressors, blowers, machine tools, conveyors and many other applications requiring 200 volt power.

Applications: Pumps, fans, compressors, blowers, machine tools, conveyors and many other applications requiring 200 volt power. 200 Volt, TEFC, Foot Mounted 1/2 thru 0 200 & 7 Volt 6C thru 26T Applications: Pumps, fans, compressors, blowers, machine tools, conveyors and many other applications requiring 200 volt power. Features:

More information

Mod Express Modification Motor Mod Express Page

Mod Express Modification Motor Mod Express Page Page No. Grinders Generators Servo s Education Catalog Index District Offices M1 Balance........................................................................... 324 M1A Dynamic Balance of Rotors M2

More information

The Energy Policy Act. The law s requirements for 1 to 200 horsepower AC motors effective October 24, 1997

The Energy Policy Act. The law s requirements for 1 to 200 horsepower AC motors effective October 24, 1997 The law s requirements for 1 to 200 horsepower AC motors effective October 24, 1997 ELECTRIC COMPANY June 12, 1997 CORPORATE OFFICE 5711 R. S. BOREHAM JR. STREET FORT SMITH, ARKANSAS 72902 U.S.A. PHONE:

More information

1/3 thru 2 Hp NEMA 56J. Aprx. Wt. (lb) Mult. Sym. C Dim. Foot Mounted. Footless

1/3 thru 2 Hp NEMA 56J. Aprx. Wt. (lb) Mult. Sym. C Dim. Foot Mounted. Footless General Super-E Jet Pump,, TEFC Pump 1/ thru 2 6J Applications: Residential and industrial pumps, swimming pool pumps, etc. Features: Diecast aluminum end plates with machined steel bearing seat insert.

More information

Motors Automation Energy Transmission & Distribution Coatings. GPH2 Combination Soft Starters

Motors Automation Energy Transmission & Distribution Coatings. GPH2 Combination Soft Starters Motors Automation Energy Transmission & Distribution Coatings GPH2 Combination Soft Starters GPH2 Combination Soft Starter 5to 350 HP The Combination Soft Starter is a NEMA 4/12 Enclosed industrial general

More information

NEMA Premium Efficiency T-Frame Motors. Three-Phase, TEFC Enclosures RELIABILITY MATTERS

NEMA Premium Efficiency T-Frame Motors. Three-Phase, TEFC Enclosures RELIABILITY MATTERS NEMA Premium Efficiency T-Frame Motors Three-Phase, TEFC Enclosures RELIABILITY MATTERS RELIABILITY MATTERS Aurora Motors a leading global supplier of NEMA premium vertical pump motors and T-frame motors

More information

Motor Accessories. C-Face Kits for Field Conversion NEMA AC Motors

Motor Accessories. C-Face Kits for Field Conversion NEMA AC Motors Definite Purpose Unit Handling C-Face Kits for Field Conversion NEMA AC Features: Complete kits with all hardware necessary for converting Baldor 56 though 449T frame ridgid base motors to C-Face mounting

More information

THREE PHASE MOTORS RIGID BASE GENERAL PURPOSE Rigid Base

THREE PHASE MOTORS RIGID BASE GENERAL PURPOSE Rigid Base THREE PHASE MOTORS DRIP-PROOF RPM 60 HP Hz 1/4 1725 1725 S56 100027 $246 A 16 208-230/460 1.4 58.0 9.24 1/3 3450 48 101447 251 A 14 208-230/460 1.4 68.0 9.00 1725 48 100446 266 A 17 208-230/460 1.6 64.3

More information

SUBMERSIBLE PUMPS DRAINER SUMP/EFFLUENT

SUBMERSIBLE PUMPS DRAINER SUMP/EFFLUENT SUBMERSIBLE PUMPS DRAINER SUMP/EFFLUENT LEESON Canada features products by well known manufacturer Berkeley which includes the Toran and Simer brand names. SUBMERSIBLE UTILITY PUMPS GEYSER II 1/6 HP 1/6

More information

WATTSAVER PREMIUM EFFICIENCY MOTORS GENERAL PURPOSE

WATTSAVER PREMIUM EFFICIENCY MOTORS GENERAL PURPOSE PREMIUM EFFICIENCY MOTORS GENERAL PURPOSE The line of premium efficiency motors is now inverter capable. LEESON s unique IRIS voltage-spike-resistant insulation system is standard at no extra cost. motors

More information

CUSTOM DC MOTORS & GEARMOTORS

CUSTOM DC MOTORS & GEARMOTORS & GEARMOTORS Battery-powered, 24-volt motor with close coupled hydraulic pump mounting on one end and standard NEMA 56 C face and shaft on other end. Totally enclosed fan cooled, SCR rated, partial motor

More information

1/3 thru 2 Hp NEMA 56J. Mult. Sym. C Dim. Foot Mounted. Footless

1/3 thru 2 Hp NEMA 56J. Mult. Sym. C Dim. Foot Mounted. Footless Jet Pump,, TEFC 1/ thru 2 6J Pump Applications: Residential and industrial pumps, swimming pool pumps, etc. General Features: Diecast aluminum end plates with machined steel bearing seat insert. All threaded

More information

Explosion Proof Motors

Explosion Proof Motors SINGLE-PHASE Foot Mount...A-110 C-Face Foot Mount...A-110 THREE-PHASE Foot Mount...A-112 C-Face Foot Mount...A-116 C-Face Footless...A-117 JP Foot Mount...A-117 ATEX Foot Mount...A-120 A-108 Fractional

More information

JM/JP Pump Motors. A Regal Brand

JM/JP Pump Motors. A Regal Brand JM/JP Pump Motors A Regal Brand General Specifications: For use with close-coupled pumps having JP mounting and shaft dimensions. In such applications, the pump impeller is mounted directly on the motor

More information

FRACTIONAL HORSEPOWER MOTORS & ACCESSORIES

FRACTIONAL HORSEPOWER MOTORS & ACCESSORIES TABLE OF CONTENTS Motor Information Guide Definitions And Abbreviations... page 2 Motor Identification Without A Nameplate What To Look For... page 3 Direct Drive Blower Motors: Two Speed... page 4 Three

More information

Farm Duty Motors WEG TOUGH For ALL Seasons. Motors Automation Energy Transmission & Distribution Coatings

Farm Duty Motors WEG TOUGH For ALL Seasons. Motors Automation Energy Transmission & Distribution Coatings WEG TOUGH For ALL Seasons Motors Automation Energy Transmission & Distribution Coatings www.weg.net/us Table of Contents Farm Duty, Single-Phase, TEFC... 4 Farm Duty, Three-Phase, TEFC... 5 Poultry Fan,

More information

DC MOTORS NEMA FRAME SCR RATED

DC MOTORS NEMA FRAME SCR RATED NEMA FRAME SCR RATED NEMA FRAME MOTORS SCR RATED High voltage permanent magnet DC motors are typically used with an SCR (thyristor) controller in applications requiring adjustable speed and constant torque

More information

Blue Max 2000 Vector Duty 2000:1 Constant Torque Motors

Blue Max 2000 Vector Duty 2000:1 Constant Torque Motors Blue Max 2000 Vector Duty 2000:1 Constant Torque Motors Applications: Blue Max motors are used in variable frequency drive applications requiring full rated torque at zero speed, utilizing Closed- or Open-Loop

More information

The Baldor Super-E. Over 1,000 Stock Motor Ratings. The Right Premium Efficient Motor for your Application. Leadership in Premium Efficiency

The Baldor Super-E. Over 1,000 Stock Motor Ratings. The Right Premium Efficient Motor for your Application. Leadership in Premium Efficiency The Baldor uper-e In the mid-70s, a southeastern tire manufacturing plant asked Baldor to increase their plant s operating efficiencies. After analyzing the efficiencies of the plant s 75 Hp motors, Baldor

More information

A. Fan motors and associated equipment shall be sized to operate at 110% of calculated loads and capacities.

A. Fan motors and associated equipment shall be sized to operate at 110% of calculated loads and capacities. PART 1: GENERAL 1.01 This design guidelines contained herein includes the requirements electric motors utilized for electric motor driven systems at Texas State University. It is the intention of this

More information

SEWPCC UPGRADING/EXPANSION PROJECT BID OPPORTUNITY SECTION LOW-VOLTAGE AC INDUCTION MOTORS

SEWPCC UPGRADING/EXPANSION PROJECT BID OPPORTUNITY SECTION LOW-VOLTAGE AC INDUCTION MOTORS SECTION 26 20 00 LOW-VOLTAGE AC INDUCTION MOTORS SEWPCC UPGRADING/EXPANSION PROJECT PART 1 GENERAL 1.1 RELATED SECTIONS A. This section applies only when referenced by a motor-driven equipment specification.

More information

Inverter (Vector) Duty: micromax TM 1000:1 Constant Torque (TENV), 20:1 Constant Torque (TEFC) Totally Enclosed

Inverter (Vector) Duty: micromax TM 1000:1 Constant Torque (TENV), 20:1 Constant Torque (TEFC) Totally Enclosed Inverter (Vector) Duty: micromax TM 1000:1 Constant Torque (TENV), 20:1 Constant Torque (TEFC) Totally Enclosed Applications: Designed for direct replacement of PMDC or any other variable speed application

More information

A Full Line of Low Voltage IEC Motors In-Stock

A Full Line of Low Voltage IEC Motors In-Stock BUILT TO PERFORM WHERE OTHERS FAIL A Full Line of Low Voltage IEC Motors In-Stock Distributed by Elektrim Motors Authorized Distributor: www.elektrimmotors.com or call 855-Go-Elektrim 0.08-220HP Low Voltage

More information

300% Motor full load amps at 80 seconds, 400% Motor full load amps at 35 seconds

300% Motor full load amps at 80 seconds, 400% Motor full load amps at 35 seconds Digital Soft Start Controls Soft Starters & 9 thru 900 s 208-460V 50/60 Hz. 9 thru 900 s 208-575V 50/60 Hz. Farm Duty Applications: Controlled ramp start and stop, minimize spillage in material handling,

More information

MAX-E1 FAMILY NEMA PREMIUM EFFICIENCY

MAX-E1 FAMILY NEMA PREMIUM EFFICIENCY MAX-E1 FAMILY NEMA PREMIUM EFFICIENCY TYPE AEHE, AEHH8N, AEHH8NCF, AEUH8NDC Effective 05-01-13 Supercedes 08-01-11 APPLICATIONS: Fans & Blowers Compressor Any Severe Duty/ Petro-Chem/ Pumps Mixers Pulp

More information

Baldor Mod Express Modification Motor Mod Express Page

Baldor Mod Express Modification Motor Mod Express Page Page No. ATEX M1 Balance... 396 M1A Dynamic Balance of Rotors M2 Bearings... 396 M2A Sealed or Double Shielded M2B Ball to Roller M2C Bearing Thermocouples M2D Bearing RTD S M2E Add Double Sealed Bearings

More information

CUSTOM DC MOTORS & GEARMOTORS

CUSTOM DC MOTORS & GEARMOTORS & GEARMOTORS Battery-powered, 24-volt motor with close coupled hydraulic pump mounting on one end and standard NEMA 56 C face and shaft on other end. Totally enclosed fan cooled, thyristor rated, partial

More information

NEMA 1, NEMA 4X and Chassis Mount Adjustable Speed Controls for DC Motors

NEMA 1, NEMA 4X and Chassis Mount Adjustable Speed Controls for DC Motors Made in the U.S.A. NEMA 1, NEMA 4X and Chassis Mount Adjustable Speed Controls for DC Motors Nema Enclosed DC Control Specifications Catalog Number BC140 or Features BC138 BC139 BC140-FBR BC154 BC160 BCWD140

More information

Products & Services EQ Series AC Drives. TEAMMaster WOUND ROTOR MOTORS WORLD SERIES SYNCHRONOUS MOTORS. EXPLOSION PROOF (Division 1, Zone 1)

Products & Services EQ Series AC Drives. TEAMMaster WOUND ROTOR MOTORS WORLD SERIES SYNCHRONOUS MOTORS. EXPLOSION PROOF (Division 1, Zone 1) 630-543-7867 Products & Services EQ7 1-1000 hp Intelligent Keypad with Extensive Diagnostics Select Any of 4 Control Methods - V/ Hz - Dynamic Torque - Sensorless Vector - Closed-loop Vector Quick Setup

More information

56 FRAME & 56C FRAME FRACTIONAL MOTORS From WorldWide Electric

56 FRAME & 56C FRAME FRACTIONAL MOTORS From WorldWide Electric 56 FRAME & FRAME FRACTIONAL MOTORS From WorldWide Electric Suitable For All General-Purpose Applications Motors Single-Phase and Three-Phase Pages -2 56 Motors Three-Phase Page 3 Stainless Steel / Washdown

More information

Applications: Conveyors, machine tools and other applications requiring adjustable speed. Mult. Sym.

Applications: Conveyors, machine tools and other applications requiring adjustable speed. Mult. Sym. HVAC Farm Duty Fractional Horsepower DC Speed Controls for PMDC DC & Controls 1/15 thru 1/4 115 VAC Single Phase 50/60 Hz. Applications: Conveyors, machine tools and other applications requiring adjustable

More information

Aquacultural Catalog. Aquacultural Catalog 508A

Aquacultural Catalog. Aquacultural Catalog 508A Aquacultural Catalog Aquacultural Catalog 508A MISSION STATEMENT To provide complete automation solutions for the United States and international market with products and service that meet or exceed customer

More information

180VC WITH B5 FLANGE / M ,6 0, / M l 5,0 0,7 192 / M ,0 0,9 223

180VC WITH B5 FLANGE / M ,6 0, / M l 5,0 0,7 192 / M ,0 0,9 223 METRIC (IEC) FRAME THYRISTOR RATED DC METRIC (IEC) FRAME MOTORS IP54 These metric dimensioned motors are built to IEC 34-1 electrical and mechanical standards. The IEC 63 and smaller frames are stocked

More information

Selecting Explosion-Proof Motors And Variable-Frequency Drive Controllers For Hazardous Environmental Applications

Selecting Explosion-Proof Motors And Variable-Frequency Drive Controllers For Hazardous Environmental Applications Selecting Explosion-Proof Motors And Variable-Frequency Drive Controllers For Hazardous Environmental Applications Application Solution Introduction Applying variable frequency power to explosion-proof

More information

TB Series Brakes Tension Control System

TB Series Brakes Tension Control System TB Series Brakes Tension Control System P-235-WE Service & Installation Instructions An Altra Industrial Motion Company Contents Installation Instructions...3 Coil Data...4 Maintenance...5 Control Connections...5

More information

WARREN COUNTY, N.Y. M/E REFERENCE A. Submit manufacturer's product data on all motors and adjustable speed drives.

WARREN COUNTY, N.Y. M/E REFERENCE A. Submit manufacturer's product data on all motors and adjustable speed drives. SECTION 230513 - MOTORS AND ADJUSTABLE SPEED DRIVES PART 1 - GENERAL 1.1 DESCRIPTION A. Provide labor, materials, equipment and services as required for the complete installation designed in Contract Documents.

More information

Commercial laundry dryer motors.

Commercial laundry dryer motors. Commercial Laundry Dryer Single Phase, Dripproof, Resilient Base Commercial laundry dryer motors. Replaces Huebsch commercial laundry dryer motors Automatic reset thermal protection Special threaded shaft

More information

EXPLOSION-PROOF MOTORS SINGLE PHASE

EXPLOSION-PROOF MOTORS SINGLE PHASE AC Motors MOTORS SINGLE PHASE Underwriters Laboratories and Canadian Standards Association Listed These explosion proof motors are designed and approved for application in hazardous environments having

More information

200 & 575 Volt Motors. 200 Volt, Three Phase, TEFC, Foot Mounted. 1/2 thru 50 Hp NEMA 56C thru 326T

200 & 575 Volt Motors. 200 Volt, Three Phase, TEFC, Foot Mounted. 1/2 thru 50 Hp NEMA 56C thru 326T Farm Duty 200 Volt, TEFC, Foot Mounted 200 & 7 Volt 1/2 thru 0 6C thru 26T Applications: Pumps, fans, compressors, blowers, machine tools, conveyors and many other applications requiring 200 volt power.

More information

NEMA MOTORS. Product overview. Product overview. Broadest line of NEMA low voltage motors in the industry

NEMA MOTORS. Product overview. Product overview. Broadest line of NEMA low voltage motors in the industry NEMA MOTORS Product overview Broadest line of NEMA low voltage motors in the industry Product overview 2 NEMA MOTORS PRODUC T OVERVIE W 3 Industry s broadest line of NEMA low voltage motors For nearly

More information

EPACT ENERGY POLICY ACT OF 1992: THE SCOPE OF ELECTRIC MOTORS SUBJECT TO EFFICIENCY STANDARDS ON OCTOBER

EPACT ENERGY POLICY ACT OF 1992: THE SCOPE OF ELECTRIC MOTORS SUBJECT TO EFFICIENCY STANDARDS ON OCTOBER EPACT ENERGY POLICY OF 1992: THE SCOPE OF ELECTRIC MOTORS SUBJECT TO EFFICIENCY STANDARDS ON OCTOBER 24, 1997 The Energy Policy Act of 1992 (EPAct) covering efficiency levels of general purpose industrial

More information

Aprx. Wt. (lb) Stainless Steel Threaded Shaft, 56J, Footless. Mult. Sym. C Dim.

Aprx. Wt. (lb) Stainless Steel Threaded Shaft, 56J, Footless. Mult. Sym. C Dim. General Information Premium Efficient Super-E Single Phase General Purpose Industrial Severe Duty Washdown Duty Explosion Proof Pump Commercial Jet Pump, Single Phase, Open /4 thru 3 Stainless Steel Threaded

More information

THOUSANDS OF SOLUTIONS. ONE MATCHED PERFECTLY TO YOUR NEEDS. PRODUCT QUICK REFERENCE GUIDE

THOUSANDS OF SOLUTIONS. ONE MATCHED PERFECTLY TO YOUR NEEDS. PRODUCT QUICK REFERENCE GUIDE THOUSANDS OF SOLUTIONS. ONE MATCHED PERFECTLY TO YOUR NEEDS. PRODUCT QUICK REFERENCE GUIDE THOUSANDS OF MOTOR AND CONTROL SOLUTIONS. ONE MATCHED PERFECTLY TO YOUR NEEDS. The LEESON brand spans more than

More information

Filtered PWM Speed Control for Permanent Magnet DC Motors

Filtered PWM Speed Control for Permanent Magnet DC Motors Instructions for Installation and Operation Filtered PWM Speed Control for Permanent Magnet DC Motors Model 0794 Speed and Direction Control up to 5/8 HP NEMA-1/IP-20 Specifications Product Type:... WPM-2148E1

More information

The Baldor Super-E. Over 1,000 Stock Motor Ratings. The Right Premium Efficient Motor for your Application. Leadership in Premium Efficiency

The Baldor Super-E. Over 1,000 Stock Motor Ratings. The Right Premium Efficient Motor for your Application. Leadership in Premium Efficiency The Baldor uper-e In the mid-70s, a southeastern tire manufacturing plant asked Baldor to increase their plant s operating efficiencies. After analyzing the efficiencies of the plant s 75 Hp motors, Baldor

More information

Ion Technologies SHR-HR Submersible Sewage Pump Single Seal, Single Phase, & Three Phase Power

Ion Technologies SHR-HR Submersible Sewage Pump Single Seal, Single Phase, & Three Phase Power Page 1 of 8 equipment and follow handling procedures per OSHA 29 CFR 1910.1030 when handling equipment after waste water source has been connected to system. WARNING: Risk of Asphyxiation. Installer(s)

More information

Three Phase Modifiable NEMA Horizontal Motors Accessories and Modifications

Three Phase Modifiable NEMA Horizontal Motors Accessories and Modifications 1. Altitude Standard motors are designed for 3,300 feet altitude and 40 C ambient temperature. Atmospheric conditions at higher altitudes inhibit the motor s ability to dissipate heat, resulting in an

More information

1/2 thru 50 Hp NEMA 56C thru 326T

1/2 thru 50 Hp NEMA 56C thru 326T 200 Volt, TEFC, Foot Mounted Cast Iron Foot Mounted 200 & 7 Volt 1/2 thru 0 6C thru 26T Applications: Pumps, fans, compressors, blowers, machine tools, conveyors and many other applications requiring 200

More information

SECTION COMMON MOTOR REQUIREMENTS FOR HVAC EQUIPMENT

SECTION COMMON MOTOR REQUIREMENTS FOR HVAC EQUIPMENT SECTION 230513 - COMMON MOTOR REQUIREMENTS FOR HVAC EQUIPMENT PART 1 GENERAL 1.1 SECTION INCLUDES A. Single phase electric motors. B. Three phase electric motors. 1.2 REFERENCE STANDARDS A. ABMA STD 9

More information

List Price. Mult. Sym. C Dim. Single Phase

List Price. Mult. Sym. C Dim. Single Phase Single and Three Phase, Foot Mounted Explosion Proof 1/4 thru 300 48 thru 449TY Applications: Ideal for use where hazardous fumes or dust may be present. Features: U.L. and CSA approved for Class I, Group

More information

1/4 thru 300 Hp NEMA 48 thru 449TY. List Price. Mult. Sym. C Dim. Single Phase

1/4 thru 300 Hp NEMA 48 thru 449TY. List Price. Mult. Sym. C Dim. Single Phase Single and Three Phase, Foot Mounted Explosion Proof 1/4 thru 300 48 thru 449TY Applications: Ideal for use where hazardous fumes or dust may be present. Features: U.L. and CSA approved for Class I, Group

More information

QUICK REFERENCE Stock Sub-FHP Gearmotors

QUICK REFERENCE Stock Sub-FHP Gearmotors Parallel Shaft PZ Series QUICK REFERENCE Stock Sub-FHP P240 & P300 Series AC Single & Three Phase Single Phase 115V 12-100 In-Lbs Page 102 Single Phase 115/230V 43-391 In-Lbs Page 103 DC SCR & Low Voltage

More information

The Baldor Super-E. Over 1,000 Stock Motor Ratings. The Right Premium Efficient Motor for your Application. Leadership in Premium Efficiency

The Baldor Super-E. Over 1,000 Stock Motor Ratings. The Right Premium Efficient Motor for your Application. Leadership in Premium Efficiency The Baldor uper-e In the mid-70s, a southeastern tire manufacturing plant asked Baldor to increase their plant s operating efficiencies. After analyzing the efficiencies of the plant s 75 Hp motors, Baldor

More information

Vertical Pump Motors

Vertical Pump Motors NEMA Premium, High, and Standard Efficiency Vertical Pump Motors WP1 or TEFC Enclosures available with Hollow Shaft or Solid Shaft RELIABILITY MATTERS RELIABILITY MATTERS Aurora Motors a leading global

More information

HVAC Motors Three Phase, TEFC, Foot Mounted, with Internal AEGIS

HVAC Motors Three Phase, TEFC, Foot Mounted, with Internal AEGIS 1 1 1/2 2 3 5 7 1/2 230/460 Volt HVAC TEFC, Foot Mounted, with Internal AEGIS 1 thru 100 56 thru 405T Bearing Protection Ring 10 15 20 25 30 40 50 3600 56 EM3545-G 773 K 12.23 33 77 230/460 1.4 143T EM3546T-G

More information

TEFC FARM DUTY/AGRICULTURE 115, 208 & 230 VOLTS 1-PHASE

TEFC FARM DUTY/AGRICULTURE 115, 208 & 230 VOLTS 1-PHASE TEFC FARM DUTY/AGRICULTURE 115, 208 & 230 VOLTS 1-PHASE FOOT MOUNT overload protection 1/3 to 10 HP Two designs to choose from: High Torque (HT) and Extra High Torque (EHT) construction and shaft slingers

More information

Integral Horsepower AC Induction Motors ODP Enclosure TEFC Enclosure

Integral Horsepower AC Induction Motors ODP Enclosure TEFC Enclosure $25.00 Integral Horsepower AC Induction Motors ODP Enclosure TEFC Enclosure Installation & Operating Manual 9/96 Table of Contents..............................................................................

More information

Stearns Super-Mod Totally-Enclosed Non-Ventilated (TENV) Modules Featuring

Stearns Super-Mod Totally-Enclosed Non-Ventilated (TENV) Modules Featuring TENV/IP54 Super-Mod Clutch-Brake Modules Imagine a totally-enclosed, nonventilated clutch-brake ready to work right out of the box, requiring no modifications. And at a price competitive with open enclosure

More information

NEMA Premium, High, and Standard Efficiency Vertical Hollow Shaft Pump Motors RELIABILITY MATTERS

NEMA Premium, High, and Standard Efficiency Vertical Hollow Shaft Pump Motors RELIABILITY MATTERS NEMA Premium, High, and Standard Efficiency RELIABILITY MATTERS Blue = 90c 50m 0y 0k Blue = Pantone 285C Gray = 40% Black (For reverse logo use 30%) R E L I A B I L I T Y M AT T E R S Aurora Motors a leading

More information

A. Motors shall be designed, built, and tested in accordance with the latest revision of the following standard documents.

A. Motors shall be designed, built, and tested in accordance with the latest revision of the following standard documents. PART 1: GENERAL 1.01 This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is to apply the

More information

Signature Series & Ultimate E Motors, High Performance & Premium Efficiency. Alum. Aluminum And Steel TEFC & ODP Motors C O M P LIA N T

Signature Series & Ultimate E Motors, High Performance & Premium Efficiency. Alum. Aluminum And Steel TEFC & ODP Motors C O M P LIA N T & Motors, High Performance & Premium Efficiency Alum. EPAct Aluminum And Steel TEFC & ODP Motors C O M P LIA N T or : High Performance and Pr Beyond Energy Efficient Lincoln and motors provide both premium

More information

INDUSTRIES AMERICAN COOLAIR CORPORATION. Centrifugal Filtered Supply Roof Ventilators TYPE CFS - TYPE SIS

INDUSTRIES AMERICAN COOLAIR CORPORATION. Centrifugal Filtered Supply Roof Ventilators TYPE CFS - TYPE SIS INDUSTRIES AMERICAN COOLAIR CORPORATION Centrifugal Filtered Supply Roof Ventilators TYPE CFS - TYPE SIS CFS Centrifugal Filtered Supply Fans Applications The CFS Centrifugal Filtered supply fans with

More information

Industrial Farm/Ag Motors

Industrial Farm/Ag Motors Industrial Farm/Ag Motors Built to last in the demanding agricultural industry. A Regal Brand Don t let a motor decide LEESON Farm/Ag Industrial Motors. 2 when your day ends. LEESON Farm/Ag motors are

More information

Electric Actuator Installation, Operation & Maintenance Manual

Electric Actuator Installation, Operation & Maintenance Manual ICI Indelac Controls, Inc. Electric Actuator Installation, Operation & Maintenance Manual 6810 Powerline dr.-florence, Ky. 41042 - Telephone 859-727-7890, Tool free 800-662-9424 Fax. 859-727-4070, e-mail:

More information

StormPro BA Series Sump Pump

StormPro BA Series Sump Pump Page 1 of 8 Marks & Meanings DANGER: Keep the pump equipment out of the reach of children! Warns that the failure to follow the directions given could cause serious risk to individuals or objects. WARNING:

More information

User s Manual and Operating Instructions

User s Manual and Operating Instructions User s Manual and Operating Instructions Model Numbers: CL-36-BDF-A, CL-42-BDF-A, CL-48-BDF-A E355088 READ AND SAVE THESE INSTRUCTIONS IMPORTANT: Read and understand all of the instructions in this manual

More information

INDEX NEMA PREMIUM EFFICIENCY

INDEX NEMA PREMIUM EFFICIENCY INDEX S EED EXC DS R TS O DAR MEE E STAN CE THREE-PHASE MOTORS - FEATURES & LIST PRICES THREE-PHASE MOTORS TEFC - Foot-Mount................... A-51 A-54 TEFC C-Flange........................ A-55 ODP

More information

300% Motor full load amps at 80 seconds, 400% Motor full load amps at 35 seconds

300% Motor full load amps at 80 seconds, 400% Motor full load amps at 35 seconds Digital Soft Start Controls 9 thru 900 Amps 208-460V 50/60 Hz. 9 thru 900 Amps 208-575V 50/60 Hz. Applications: Controlled ramp start and stop, minimize spillage in material handling, reduced water hammer

More information

Catalog Number. List Price. Wheel Size. List Price. Catalog Number. Wheel Size. Wheel Size. List Price. Catalog Number. Wheel Size.

Catalog Number. List Price. Wheel Size. List Price. Catalog Number. Wheel Size. Wheel Size. List Price. Catalog Number. Wheel Size. Generators Servo s Industrial 600E 623E Cast aluminum wheel guards can be exhausted or left closed. 8-foot power cord. Base mounted on/off switch. Rubber feet minimize vibration. Cast aluminum non-exhaust

More information

Super-E Premium Efficient Motors

Super-E Premium Efficient Motors Super-E Premium Efficient Motors Why Baldor? Customer Preference 20% 1985 50% 1990 90% 2000 94% 2003 95.5% 2007 The percentages shown reflect results of studies conducted in which Baldor was chosen as

More information

Why Baldor? Table of Contents.

Why Baldor? Table of Contents. Pump Motors Why Baldor? Industry s shortest lead times/flexible manufacturing. Baldor has the industry s shortest lead times on custom motors just ten working days. Our unique LEAN FLEX FLOW manufacturing

More information

J 6 Se r i e s. Pressure and Vacuum switches. features

J 6 Se r i e s. Pressure and Vacuum switches. features J 6 S er i es J 6 Se r i e s Pressure and Vacuum switches features Gasketed, Die Cast Aluminum Enclosure with Epoxy Coating SPDT Switch Output Adjustable Deadband Option Sealed, Isolated Metal Bellows

More information

Family Frame Size Constant Torque Variable Torque Comments Super-E Motors 230, 460 and 575 Volts (1) (1) 20:1 10:1

Family Frame Size Constant Torque Variable Torque Comments Super-E Motors 230, 460 and 575 Volts (1) (1) 20:1 10:1 ac Motor adjustable speed range capabilities & Controls inverter drive and vector drive Inverter Drive and Vector Drive exceed all requirements of NEMA MG-1 Parts 30 and 31 for AC induction motors powered

More information

WARRANTY POLICY. Grid-Tied Photovoltaic Inverters. Revision D. 2014, Solectria Renewables, LLC DOCIN

WARRANTY POLICY. Grid-Tied Photovoltaic Inverters. Revision D. 2014, Solectria Renewables, LLC DOCIN WARRANTY POLICY Revision D 2014, Solectria Renewables, LLC DOCIN-070360 1 Product Warranty & RMA Policy 1. Warranty Policy Warranty Registration: It is important to have updated information about the inverter

More information