List Price. Mult. Sym. C Dim. Single Phase

Size: px
Start display at page:

Download "List Price. Mult. Sym. C Dim. Single Phase"

Transcription

1 Single and Three Phase, Foot Mounted Explosion Proof 1/4 thru thru 449TY Applications: Ideal for use where hazardous fumes or dust may be present. Features: U.L. and CSA approved for Class I, Group D and Class I, Group C & D and Class II, Group F & G. Corrosion resistant epoxy finish. Shipped with U.L. and CSA approved cast conduit box assembled to each motor Service Factor. EM Super-E explosion proof motors have Premium efficiency and 3 year warranty. 48 L4003A ➇ 487 K / C 1/4 56 L5000A ➇ 465 K / C 56 L5000A-C ➃ 579 K / C 48 L4005A ➇ 432 K /230 3 C 1/3 48 L4006A ➇ 628 K / C 56 L5001A ➇ 598 K / C 56 L5002A ➆ 847 K / C 56 L5003A ➇ 567 K / C 48 L4009A ➇ 691 K / C 1/2 56 L5004A ➇ 659 K / C 56 L5004A-C ➃ 773 K / C 56 L5005A ➆ 976 K /230 4 C 56 L5006A ➆ 640 K / C 3/4 56 L5007A ➆ 775 K / C 56 L5007A-C ➁ 888 K / C 56 L5022 ➀ 1,128 K / C 56 L5009A ➆ 691 K /230 6 C 1 56 L5023A ➀ 882 K / C 143T L5023T ➀ 864 L / C 184 L5026 ➇ 1,933 L / C 1 1/2 143T L5030T ➇ 1,001 L / C 184 L5013 ➇ 1,795 L / C 2 145T L5031T ➇ 1,238 L / C 182T L5027T ➀ 1,819 L / C 3 184T L5028T ➀ 1,890 L / C 215 L5018 ➇ 2,872 L / C L5020 ➀ 3,653 L C Three Phase 1/4 48 M6002A ➇ 507 K / C 1/3 56 M7002A ➇ 609 K / C 56 M7003A ➆ 874 K / C 56 M7005A ➇ 698 K / C 1/2 48 M6007A ➇ 634 K /460 1 C 56 M7006A ➇ 634 K /460 1 C 56 M7007A ➆ 923 K / C 56 M7009A ➇ 727 K / C 56 M7010A ➇ 730 K / C 3/4 56 M7031A ➆ 980 K / C 143T M7031TA ➆ 980 L / C Super-E Industrial Pump Commercial CAUTION: Explosion-proof motors have a tight fit between mating parts to ensure the integrity of the explosion-proof enclosure. This can lead to an accumulation of moisture inside the motors due to condensation. Care should be used when selecting an explosion-proof motor, especially when installed outdoors and on intermittent duty. Consider explosion-proof motors on pages for outdoor applications. These explosion-proof motors are not suitable for use with adjustable speed drives, inverter duty explosion-proof motors must be used. See page 232. HVAC 101

2 Super-E Industrial Pump Commercial Single and Three Phase, Foot Mounted 1 1 1/2 2 3 Cast Iron Explosion Proof CAUTION: Explosion-proof motors have a tight fit between mating parts to ensure the integrity of the explosion-proof enclosure. This can lead to an accumulation of moisture inside the motors due to condensation. Care should be used when selecting an explosion-proof motor, especially when installed outdoors and on intermittent duty. Consider explosion-proof motors on pages for outdoor applications. These explosion-proof motors are not suitable for use with adjustable speed drives, inverter duty explosion-proof motors must be used. See page M7013 ➇ 766 K / C 56 M7014 ➇ 799 K / C T EM7014T ➇ 1,116 L / A T EM7114T ➇ 1,536 L / A T EM7114T-C ➁ 1,273 L / A T M7014T ➇ 833 LS / D T M7114T ➇ 1,181 LS / D M7015 ➇ 1,152 L / B M7032 ➀ 980 K / C 145T EM7032T ➇ 1,248 L / A 145T M7032T ➇ 960 L / D 143T EM7018T ➇ 1,021 L / A T M7018T ➇ 786 L / D M7034 ➇ 870 K / C T EM7034T ➇ 1,156 L /460 2 A T EM7134T ➇ 1,556 L / A 145T EM7134T-C ➁ 1,303 L / A 145T M7034T ➇ 835 LS / D T M7134T ➇ 1,197 LS / D 184 M7019 ➇ 1,460 L / B T EM7020T ➇ 1,718 L / A T EM7120T ➇ 1,910 L / A T M7020T ➇ 1,322 L / D T EM7071T ➇ 1,045 L / A T M7071T ➇ 804 L / D M7037 ➇ 973 K / C 145T EM7037T ➇ 1,261 L / A T EM7137T ➇ 1,638 L / A T EM7137T-C ➁ 1,339 L / A 145T M7037T ➇ 942 LS / D T M7137T ➇ 1,260 LS / D M7023 ➇ 1,495 L / B T EM7041T ➇ 1,770 L / A T M7041T ➇ 1,361 L / D T EM7075T ➀ 1,238 L / A 145T M7075T ➀ 952 L / D 182T EM7026T ➇ 1,308 L / A T EM7126T ➇ 1,759 L / A T M7026T ➇ 1,006 L / D T M7126T ➇ 1,353 L / D M7026 ➇ 1,278 L / B T EM7042T ➇ 1,340 L / A T EM7142T ➇ 1,636 L /460 4 A T EM7142T-C ➁ 1,448 L /460 4 A T M7042T ➇ 1,030 LS / D T M7142T ➇ 1,258 LS / D M7027 ➇ 1,708 L / B T EM7036T ➇ 1,929 L / A T M7036T ➇ 1,484 L / D 19 HVAC 102

3 Single and Three Phase, Foot Mounted Explosion Proof 5 7 1/ a) See notes on inside back flap. Cast Iron CAUTION: Explosion-proof motors have a tight fit between mating parts to ensure the integrity of the explosion-proof enclosure. This can lead to an accumulation of moisture inside the motors due to condensation. Care should be used when selecting an explosion-proof motor, especially when installed outdoors and on intermittent duty. Consider explosion-proof motors on pages for outdoor applications. These explosion-proof motors are not suitable for use with adjustable speed drives, inverter duty explosion-proof motors must be used. See page T EM7072T ➇ 1,538 L / A T EM7172T ➇ 2,062 L / A T M7072T ➇ 1,183 L / D T M7172T ➇ 1,586 L / D T EM7044T ➇ 1,660 L / A T EM7144T ➇ 2,051 L / A T EM7144T-C ➁ 1,746 L / A T M7044T ➇ 1,277 LS / D T M7144T ➇ 1,490 LS / D M7030 ➇ 2,211 L /460 7 B T EM7040T ➇ 2,529 L / A T M7040T ➇ 1,945 L / D T EM7073T ➀ 2,018 L / A T M7073T ➀ 1,528 L / D 213T EM7045T ➇ 2,122 L / A T EM7145T ➇ 2,379 L / A T M7045T ➇ 1,632 L / D T M7145T ➇ 1,830 L / D T EM7047T ➇ 2,204 L / A T EM7147T ➇ 2,430 L / A T EM7147T-C ➁ 2,184 L / A T M7047T ➇ 1,574 LS / D T M7147T ➇ 1,800 LS / D T EM7048T ➇ 2,994 L / A T M7048T ➇ 2,303 L / D T EM7074T ➀ 2,392 L / A 215T EM7174T ➇ 2,496 L / A T M7074T ➀ 1,841 L / D 215T M7174T ➇ 1,920 L / D T EM7070T ➇ 2,462 L / A 215T EM7170T ➇ 3,114 LS / A T EM7170T-C ➃ 3,035 L / A T M7070T ➇ 1,652 LS / D 215T M7170T ➇ 2,124 LS / D T EM7065T ➇ 3,600 L / A T M7065T ➇ 2,769 L / D T EM7053T ➇ 2,822 L / A T M7053T ➇ 2,171 L / D T EM7054T ➇ 3,307 L / A T EM7054T-C ➁ 3,388 L / A T M7054T ➇ 2,461 LS / D T EM7057T ➇ 5,803 L / A T M7057T ➇ 4,464 L / D T EM7059T ➇ 3,619 L / A T M7059T ➇ 2,784 L / D T EM7056T ➇ 4,285 L / A T EM7056T-C ➁ 4,375 L / A T M7056T ➇ 3,191 LS / D T EM7079T ➇ 5,958 L / A T M7079T ➇ 4,583 L / D 19 Super-E Industrial Pump Commercial HVAC 103

4 Super-E Industrial Pump Commercial Single and Three Phase, Foot Mounted Cast Iron Explosion Proof 284TS EM7063T ➇ 4,817 L / A TS M7063T ➇ 3,705 L / D T EM7058T ➇ 5,199 L / A T EM7058T-C ➁ 5,300 L / A T M7058T ➇ 3,948 LS / D T EM7082T ➇ 7,450 L / A T M7082T ➇ 5,731 L / D TS EM7083T ➇ 5,662 L / A TS M7083T ➇ 4,355 L / D T EM7060T ➇ 6,338 L / A T EM7060T-C ➁ 6,443 L / A T M7060T ➇ 4,719 LS / D T EM7080T ➇ 8,219 L / A T M7080T ➇ 6,322 L / D TS EM7067T ➇ 7,552 L / A TS M7067T ➇ 5,809 L / D T EM7062T ➇ 8,494 L / A T EM7062T-C ➁ 8,609 L / A T M7062T ➇ 6,447 LS / D T EM7084T ➇ 9,526 L / A T M7084T ➇ 7,328 L / D TS EM7081T ➇ 9,670 L / A TS M7081T ➇ 7,439 L / D T EM7064T ➇ 11,326 LS / A T EM7064T-C ➁ 9,996 L / A T M7064T ➇ 7,501 LS / D T EM7085T ➆ 10,751 L / A T M7085T ➆ 8,270 L / D T EM7066T ➆ 12,670 LS / A T EM7066T-C ➁ 11,174 L / A T M7066T ➆ 8,390 LS / D T EM7086T ➆ 12,828 L / A T M7086T ➆ 9,868 L / D T EM7068T ➁ 13,345 L / A 19, T M7068T ➁ 10,465 LS / D T EM7087T ➆ 14,352 L / A T M7087T ➆ 11,224 L / D T EM7090T ➁ 15,498 L / A T M7090T ➁ 12,398 LS / D T EM74124T-4 ➁ 18,111 L A T M74124T-4 ➁ 16,567 LS D T EM74154T-4 ➁ 20,240 L A T M74154T-4 ➁ 18,347 LS D T EM74204T-4 ➁ 28,930 L A T M74204T-4 ➁ 27,037 LS D 19, T M74254T-4 ➁ 31,526 L B 19, TY M74304T-4 ➁ 46,928 L B 19, 20 CAUTION: Explosion-proof motors have a tight fit between mating parts to ensure the integrity of the explosion-proof enclosure. This can lead to an accumulation of moisture inside the motors due to condensation. Care should be used when selecting an explosion-proof motor, especially when installed outdoors and on intermittent duty. Consider explosion-proof motors on pages for outdoor applications. These explosion-proof motors are not suitable for use with adjustable speed drives, inverter duty explosion-proof motors must be used. See page 232. HVAC 104

5 Single and Three Phase, C-Face Explosion Proof 1/3 thru 50 56C thru 326TC Applications: Ideal for use on pumps, blowers and valves installed where hazardous fumes or dust may be present. Features: Corrosion resistant epoxy finish. Positively locked drive end bearing. U.L. approved cast conduit box-standard S.F. U.L. and CSA approved for Class 1, Group D, Class 2, Group F & G Efficiency and 3 year warranty. No drip cover. CAUTION: Explosion-proof motors have a tight fit between mating parts to ensure the integrity of the explosion-proof enclosure. This can lead to an accumulation of moisture inside the motors due to condensation. Care should be used when selecting an explosion-proof motor, especially when installed outdoors and on intermittent duty. Consider explosion-proof motors on pages for outdoor applications. These explosion-proof motors are not suitable for use with adjustable speed drives, inverter duty explosion-proof motors must be used. See page 232., C-Face, Foot Mounted 1/3 56C CL5001A ➇ 729 K / C 1/2 56C CL5003A ➇ 640 K / C 56C CL5004A ➇ 730 K / C 3/4 56C CL5007A ➆ 814 K / C 1 56C CL5009A ➆ 726 K /230 6 C 56C CL5023A ➀ 925 K / C 1 1/2 143TC CL5030T ➇ 1,138 L / C 184C CL5013 ➇ 1,847 L / C 2 143TC CL5031T ➇ 1,301 L / C 182TC CL5027T ➀ 1,906 L / C 3 184TC CL5028T ➀ 1,928 L / C 215C CL5018 ➇ 2,958 L / C 5 215C CL5020 ➀ 3,766 L C, C-Face, Footless 1/4 56C VL5000A ➇ 645 K / C 56C VL4005A ➇ 491 K / C 1/3 56C VL5001A ➇ 659 K / C 56C VL5002A ➆ 883 K / C 56C VL5003A ➇ 635 K / C 1/2 56C VL5004A ➇ 728 K / C 56C VL5005A ➆ 1,013 K /230 4 C 3/4 56C VL5006A ➆ 679 K / C 56C VL5007A ➆ 811 K / C 1 56C VL5009A ➆ 728 K /230 6 C 56C VL5023A ➀ 921 K / C 1 1/2 56C VL5030 ➀ 1,048 K / C 56C VL5024A ➀ 1,216 K /230 8 C 2 184C VL5027 ➀ 1,934 L / C Three Phase, C-Face, Foot Mounted 1/2 56C CM7005A ➇ 764 K / C 56C CM7006A ➇ 827 K /460 1 C 3/4 56C CM7009A ➇ 789 K / C 56C CM7010A ➇ 843 K / C 56C CM7013 ➇ 825 K / C 1 56C CM7014 ➇ 899 K / C TC CEM7014T ➇ 1,183 L /460 0 A TC CM7014T ➇ 899 L / D 19 Super-E Industrial Pump Commercial HVAC 105

6 Super-E Industrial Pump Commercial 106 HVAC Single and Three Phase, C-Face Cast Iron Explosion Proof 143TC CEM7018T ➇ 1,171 L / A TC CM7018T ➇ 935 L / D /2 56C CM7034 ➇ 958 K / C TC CEM7034T ➇ 1,281 L /460 0 A TC CM7034T ➇ 958 L / D TC CEM7071T ➇ 1,168 L / A TC CM7071T ➇ 1,032 L / D C CM7037 ➇ 1,037 K / C TC CEM7037T ➇ 1,357 L / A TC CM7037T ➇ 1,037 L / D TC CEM7075T ➀ 1,448 L / A TC CM7075T ➀ 1,162 L / D TC CEM7042T ➇ 1,645 L / A TC CM7042T ➇ 1,336 L / D TC CEM7072T ➇ 1,910 L / A TC CM7072T ➇ 1,555 L / D TC CEM7044T ➇ 1,989 L / A TC CM7044T ➇ 1,607 L / D TC CEM7073T ➀ 2,243 L / A TC CM7073T ➀ 1,753 L / D TC CEM7045T ➇ 2,545 L / A /2 213TC CM7045T ➇ 2,055 L / D TC CEM7047T ➇ 2,333 L / A TC CM7047T ➇ 2,088 L / D TC CEM7174T ➇ 2,778 L / A TC CM7174T ➇ 2,202 L / D TC CEM7170T ➇ 2,838 L / A TC CM7170T ➇ 2,202 L / D TC CEM7053T ➇ 4,014 L / A TC CM7053T ➇ 2,363 L / D TC CEM7054T ➇ 4,694 L / A TC CM7054T ➇ 3,843 L / D TC CEM7059T ➇ 4,812 L / A TC CM7059T ➇ 2,978 L / D TC CEM7056T ➇ 5,564 L / A TC CM7056T ➇ 4,464 L / D TSC CEM7063T ➇ 5,000 L / A TSC CM7063T ➇ 3,888 L / D TC CEM7058T ➇ 6,813 L / A TC CM7058T ➇ 5,555 L / D TC CEM7060T ➇ 7,907 L / A TC CM7060T ➇ 6,279 L / D TC CEM7062T ➇ 10,547 L / A TC CM7062T ➇ 8,488 L / D Three Phase, C-Face, Footless 326TC CEM7064T ➇ 11,993 L / A TC CM7064T ➇ 9,600 L / D 19 1/4 56C VM7001A ➇ 768 K / C 1/3 56C VM7002A ➇ 784 K / C 56C VM7005A ➇ 759 K / C 1/2 56C VM7006A ➇ 825 K /460 1 C 56C VM7007A ➆ 960 K / C 56C VM7009A ➇ 784 K / C 3/4 56C VM7010A ➇ 840 K / C 56C VM7031A ➆ 1,008 K / C CAUTION: Explosion-proof motors have a tight fit between mating parts to ensure the integrity of the explosion-proof enclosure. This can lead to an accumulation of moisture inside the motors due to condensation. Care should be used when selecting an explosion-proof motor, especially when installed outdoors and on intermittent duty. Consider explosion-proof motors on pages for outdoor applications. These explosion-proof motors are not suitable for use with adjustable speed drives, inverter duty explosion-proof motors must be used. See page 232.

7 Single and Three Phase, C-Face Explosion Proof CAUTION: Explosion-proof motors have a tight fit between mating parts to ensure the integrity of the explosion-proof enclosure. This can lead to an accumulation of moisture inside the motors due to condensation. Care should be used when selecting an explosion-proof motor, especially when installed outdoors and on intermittent duty. Consider explosion-proof motors on pages for outdoor applications. These explosion-proof motors are not suitable for use with adjustable speed drives, inverter duty explosion-proof motors must be used. See page C VM7013 ➇ 817 K / C 1 56C VM7014 ➇ 882 K / C 143TC VM7014T ➇ 952 L / B 19 56C VM7032 ➀ 1,062 K / C 143TC VM7018T ➇ 1,003 L / B /2 56C VM7034 ➇ 950 K / C TC VM7034T ➇ 1,026 L / B TC VM7035T ➀ 1,173 L / B 145TC VM7071T ➇ 1,122 L / B C VM7037 ➇ 1,027 K / C TC VM7037T ➇ 1,110 L / B TC VM7075T ➀ 1,245 L / B 3 182TC VM7026T ➇ 1,313 L / B TC VM7042T ➇ 1,423 L / B TC VM7072T ➇ 1,660 L /460 6 B TC VM7044T ➇ 1,733 L / B TC VM7073T ➀ 1,874 L / B /2 213TC VM7045T ➇ 2,182 L / B TC VM7047T ➇ 2,006 L / B TC VM7170T ➇ 2,433 L / B 19 HVAC Super-E Industrial Commercial Pump 107

8 Super-E 575 Volt, Three Phase, Explosion Proof Explosion Proof 1/2 thru thru 324T Applications: Shakers, blowers, pumps, mixers, etc. Features: All models have torques exceeding standards, copper windings, rotors that are corrosion treated and precision balanced Service Factor. UL and CSA approved for Class I, Group D, Class II, Group, F & G, T3C. Industrial Pump Commercial Cast Iron CAUTION: Explosion-proof motors have a tight fit between mating parts to ensure the integrity of the explosion-proof enclosure. This can lead to an accumulation of moisture inside the motors due to condensation. Care should be used when selecting an explosion-proof motor, especially when installed outdoors and on intermittent duty. The Explosion-proof motors are not suitable for use with adjustable speed drives. Inverter Duty Explosion-proof motors must be used. See page 232. Foot Mounted, No Drip Cover 1/2 56 M ➇ 634 K C 3/4 56 M ➇ 730 K C 56 M ➇ 766 K C 1 56 M ➇ 799 K C 143T EM7014T-5 ➇ 1,280 LS A 143T M7014T-5 ➇ 833 LS D 1 1/2 143T EM7018T-5 ➇ 1,021 L A 143T M7018T-5 ➇ 786 L D 145T EM7034T-5 ➇ 1,326 LS A 145T M7034T-5 ➇ 835 LS D 2 145T EM7071T-5 ➇ 1,045 L A 145T M7071T-5 ➇ 804 L D 145T EM7037T-5 ➇ 1,446 LS A 145T M7037T-5 ➇ 942 LS D 3 182T EM7042T-5 ➇ 1,340 L A 182T M7042T-5 ➇ 1,030 LS D 5 184T EM7072T-5 ➇ 1,538 L A 184T M7072T-5 ➇ 1,183 L D 184T EM7044T-5 ➇ 1,660 L A 184T M7044T-5 ➇ 1,277 LS D 7 1/2 213T EM7047T-5 ➇ 2,204 L A 213T M7047T-5 ➇ 1,574 LS D T EM7170T-5 ➇ 2,767 L A 215T M7170T-5 ➇ 2,131 L D T EM7054T-5 ➇ 3,791 LS A 254T M7054T-5 ➇ 2,461 LS D T EM7056T-5 ➇ 4,913 LS A 256T M7056T-5 ➇ 3,191 LS D T EM7058T-5 ➇ 5,960 LS A 284T M7058T-5 ➇ 3,948 LS D T EM7060T-5 ➇ 7,266 L A 286T M7060T-5 ➇ 4,735 L D T EM7062T-5 ➇ 9,738 LS A 324T M7062T-5 ➇ 6,447 LS D HVAC 108

9 575 Volt, Three Phase, Explosion Proof Explosion Proof C-Face, Footless, No Drip Cover 1/2 56C VM ➇ 825 K C 3/4 56C VM ➇ 840 K C 56C VM ➇ 882 K C 1 143TC VEM7014T-5 ➇ 1,167 L B 143TC VM7014T-5 ➇ 952 L B 1 1/2 145TC VEM7034T-5 ➇ 1,272 L B 145TC VM7034T-5 ➇ 1,026 L B 2 145TC VEM7037T-5 ➇ 1,348 L B 145TC VM7037T-5 ➇ 1,110 L B 3 182TC VEM7042T-5 ➇ 1,522 L B 182TC VM7042T-5 ➇ 1,423 L B 5 184TC VEM7044T-5 ➇ 1,798 L B 184TC VM7044T-5 ➇ 1,733 L B 7 1/2 213TC VM7047T-5 ➇ 2,006 L B Cast Iron CAUTION: Explosion-proof motors have a tight fit between mating parts to ensure the integrity of the explosion-proof enclosure. This can lead to an accumulation of moisture inside the motors due to condensation. Care should be used when selecting an explosion-proof motor, especially when installed outdoors and on intermittent duty. The Explosion-proof motors are not suitable for use with adjustable speed drives. Inverter Duty Explosion-proof motors must be used. See page 232. HVAC Super-E Industrial Commercial Pump 109

10 Super-E Industrial Pump Commercial, Three Phase, 1.15 Service Factor Explosion Proof 3 182T EM7542T-I ➂ 1,389 SD / A 1 213T EM7536T-I ➂ 1,996 SD / A 1 184T EM7572T-I ➂ 1,827 SD / A T EM7544T-I ➂ 1,721 SD / A 1 215T EM7540T-I ➂ 2,618 SD / A 1 7 1/2 213T EM7547T-I ➂ 2,122 SD / A 1 254T EM7548T-I ➂ 3,099 SD / A 1 215T EM7574T-I ➂ 2,583 SD / A T EM7670T-I ➂ 2,865 SD / A 1 256T EM7565T-I ➂ 3,726 SD / A T EM7554T-I ➂ 3,436 SD / A T EM7559T-I ➂ 3,746 SD / A 1 256T EM7556T-I ➂ 4,302 SD / A T EM7558T-I ➂ 5,400 SD / A T EM7560T-I ➂ 6,595 SD / A T EM7562T-I ➂ 8,825 SD / A T EM7564T-I ➂ 10,267 SD / A 1 365T EM7585T-I ➂ 11,127 SD / A T EM7566T-I ➂ 11,608 SD / A T EM7568T-I ➂ 12,083 SD / A 1 405T EM7587T-I ➂ 14,855 SD / A T EM7590T-I ➂ 15,497 SD A 1 444T EM7599T-I ➂ 18,402 SD A T EM7600T-I ➂ 18,709 SD A T EM7596T-I ➂ 20,908 SD A 1 Cast Iron 3 thru T thru 445T Applications: Harsh industrial environments requiring protection against corrosion, that contain hazardous gas and vapor, dust fibers, filings or other material that may have explosive properties. Features: 1.15 Service factor, design includes rugged cast iron construction with corrosion resistant expoxy finish. Shaft slingers & inner caps installed on both ends of motor for bearing protection. Includes normally closed thermostats. UL & CSA approved for Division 1, Class 1, Group D, Class 2, Group E, F & G, T3C temperature code. These motors expel condensation better than standard explosion proof designs. They are recommended for applications where motors may run intermittently, applications where explosion-proof motors are installed outdoors exposed to the environment, and may not be operated for extended periods of time. These explosion-proof motors are not suitable for use with adjustable speed drives. Inverter duty explosion-proof motors must be used. See page 232. HVAC 110

11 Drill Rig Duty, Three Phase, 1.15 Service Factor Explosion Proof 1 thru C thru 405T Applications: On and off shore drill rig service, bulk fuel terminals, and transfer stations. For use in high humidity hazardous-duty applications driving pumps, compressors, blowers, fans, and many other loads that require 1.15 service factor explosion-proof motors. Designed with features for use in the petroleum industry. Includes Class I, Group C & D approval for use in areas where hydrogen sulfide is present. Features: Labyrinth-type recessed shaft slinger for increased bearing protection Explosion-proof breather/drain to prevent build up of condensation. 40 C ambient, Class F insulation. Corrosion resistant finish with two part epoxy coating. UL and CSA approved for Class I, Group C & D service factor. Suitable for service factor. Super-E Foot Mounted 143T EM7013T-I ➄ 1,144 SD / A 1, T M7013T-I ➄ 880 SD / D 1, T EM7014T-I ➄ 1,126 SD / A 1, T M7014T-I ➄ 841 SD / D 1, T EM7032T-I ➄ 1,248 SD / A 1, T M7032T-I ➄ 960 SD / D 1, T EM7018T-I ➄ 1,135 SD / A 1, T M7018T-I ➄ 900 SD / D 1, /2 145T EM7034T-I ➄ 1,166 SD /460 2 A 1, T M7034T-I ➄ 843 SD / D 1, T EM7020T-I ➄ 1,718 SD / A 1, T M7020T-I ➄ 1,322 SD / D 1, T EM7071T-I ➄ 1,241 SD / A 1, T M7071T-I ➄ 1,000 SD / D 1, T EM7037T-I ➄ 1,271 SD / A 1, T M7037T-I ➄ 951 SD / D 1, T EM7041T-I ➄ 1,770 SD / A 1, T M7041T-I ➄ 1,361 SD / D 1, T EM7026T-I ➄ 1,422 SD / A 1, T M7026T-I ➄ 1,121 SD / D 1, T EM7042T-I ➄ 1,341 SD / A 1, T EM7042T-I-5 ➄ 1,341 SD A 1, T M7042T-I ➄ 1,033 SD / D 1, T M7042T-I-5 ➄ 1,033 SD D 1, T EM7036T-I ➄ 1,929 SD / A 1, T M7036T-I ➄ 1,484 SD / D 1, T EM7072T-I ➄ 1,766 SD / A 1, T M7072T-I ➄ 1,412 SD / D 1, T EM7044T-I ➄ 1,663 SD / A 1, T EM7044T-I-5 ➄ 1,663 SD A 1, T M7044T-I ➄ 1,281 SD / D 1, T M7044T-I-5 ➄ 1,281 SD D 1, T EM7040T-I ➄ 2,529 SD / A 1, T M7040T-I ➄ 1,945 SD / D 1, T EM7045T-I ➄ 2,122 SD / A 1, T M7045T-I ➄ 1,632 SD / D 1, T EM7047T-I ➄ 2,050 SD / A 1, /2 213T EM7047T-I-5 ➄ 2,050 SD A 1, T M7047T-I ➄ 1,579 SD / D 1, T M7047T-I-5 ➄ 1,579 SD D 1, T EM7048T-I ➄ 2,994 SD / A 1, T M7048T-I ➄ 2,303 SD / D 1, 19 Cast Iron These motors expel condensation better than standard explosion proof designs. They are recommended for applications where motors may run intermittently, applications where explosion-proof motors are installed outdoors exposed to the environment, and may not be operated for extended periods of time. These explosion-proof motors are not suitable for use with adjustable speed drives. Inverter duty explosion-proof motors must be used. See page 232. Industrial Pump Commercial HVAC 111

12 Super-E Industrial Pump Commercial HVAC Drill Rig Duty, Three Phase, 1.15 Service Factor Explosion Proof 215T EM7174T-I ➄ 2,496 SD / A 1, T M7174T-I ➄ 1,920 SD / D 1, T EM7170T-I ➄ 2,767 SD / A 1, T EM7170T-I-5 ➄ 2,767 SD A 1, T M7170T-I ➄ 2,131 SD / D 1, T M7170T-I-5 ➄ 2,131 SD D 1, T EM7065T-I ➄ 3,600 SD / A 1, T M7065T-I ➄ 2,769 SD / D 1, T EM7053T-I ➄ 2,822 SD / A 1, T M7053T-I ➄ 2,171 SD / D 1, T EM7054T-I ➄ 3,320 SD / A 1, T EM7054T-I-5 ➄ 3,320 SD A 1, T M7054T-I ➄ 2,469 SD / D 1, T M7054T-I-5 ➄ 2,469 SD D 1, T EM7057T-I ➄ 5,803 SD / A 1, T M7057T-I ➄ 4,464 SD / D 1, T EM7059T-I ➄ 3,619 SD / A 1, T M7059T-I ➄ 2,784 SD / D 1, T EM7056T-I ➄ 4,156 SD / A 1, T EM7056T-I-5 ➄ 4,156 SD A 1, T M7056T-I ➄ 3,201 SD / D 1, T M7056T-I-5 ➄ 3,201 SD D 1, T EM7079T-I ➄ 5,958 SD / A 1, T M7079T-I ➄ 4,583 SD / D 1, TS EM7063T-I ➄ 4,817 SD / A 1, TS M7063T-I ➄ 3,705 SD / D 1, T EM7058T-I ➄ 5,218 SD / A 1, T EM7058T-I-5 ➄ 5,218 SD A 1, T M7058T-I ➄ 3,960 SD / D 1, T M7058T-I-5 ➄ 3,960 SD D 1, T EM7082T-I ➄ 7,450 SD / A 1, T M7082T-I ➄ 5,731 SD / D 1, TS EM7083T-I ➄ 5,662 SD / A 1, TS M7083T-I ➄ 4,355 SD / D 1, T EM7060T-I ➄ 6,363 SD / A 1, T EM7060T-I-5 ➄ 6,363 SD A 1, T M7060T-I ➄ 4,735 SD / D 1, T M7060T-I-5 ➄ 4,735 SD D 1, T EM7080T-I ➄ 8,219 SD / A 1, T M7080T-I ➄ 6,322 SD / D 1, TS EM7067T-I ➄ 7,552 SD / A 1, TS M7067T-I ➄ 5,809 SD / D 1, T EM7062T-I ➄ 8,527 SD / A 1, T EM7062T-I-5 ➄ 8,527 SD A 1, T M7062T-I ➄ 6,468 SD / D 1, T M7062T-I-5 ➄ 6,468 SD D 1, T EM7084T-I ➄ 9,526 SD / A 1, T M7084T-I ➄ 7,328 SD / D 1, TS EM7081T-I ➄ 9,670 SD / A 1, TS M7081T-I ➄ 7,439 SD / D 1, T EM7064T-I ➄ 9,919 SD / A 1, T EM7064T-I-5 ➄ 9,919 SD A 1, T M7064T-I ➄ 7,526 SD / D 1, T M7064T-I-5 ➄ 7,526 SD D 1, T EM7085T-I ➄ 10,751 SD / A 1, T M7085T-I ➄ 8,270 SD / D 1, 19 Cast Iron These motors expel condensation better than standard explosion proof designs. They are recommended for applications such as fuel transfer terminals and fuel truck loading facilities where motors may run intermittently, applications where explosion-proof motors are installed outdoors exposed to the environment, and may not be operated for extended periods of time. These explosion-proof motors are not suitable for use with adjustable speed drives. Inverter duty explosion-proof motors must be used. See page

13 Drill Rig Duty, Three Phase, 1.15 Service Factor Explosion Proof 364TS EM7310T-I ➄ 10,386 SD / A 1, TS M7310T-I ➄ 8,593 SD / D 1, T EM7066T-I ➄ 11,215 SD / A 1, T EM7066T-I-5 ➄ 11,215 SD A 1, T M7066T-I ➄ 8,537 SD / D 1, T M7066T-I-5 ➄ 8,537 SD D 1, T EM7086T-I ➄ 12,562 SD / A 1, T M7086T-I ➄ 9,868 SD / D 1, TS M7313T-I ➄ 9,958 SD / D 1, TS EM7313T-I ➄ 11,687 SD / A 1, T EM7068T-I ➄ 11,675 SD / A 1, T EM7068T-I-5 ➄ 11,675 SD A 1, T M7068T-I ➄ 10,500 SD / D 1, T M7068T-I-5 ➄ 10,500 SD D 1, T EM7087T-I ➄ 14,352 SD / A 1, T M7087T-I ➄ 11,224 SD / D 1, T EM7090T-I ➄ 14,973 SD / A 1, T EM7090T-I-5 ➄ 14,973 SD A 1, T M7090T-I ➄ 12,693 SD / D 1, T M7090T-I-5 ➄ 12,693 SD D 1, 19 C-Face, Foot Mounted 1/2 56C CM7006-I ➄ 827 SD / C 1, 19 3/4 56C CM7010-I ➄ 843 SD / C 1, C CM7014-I ➄ 899 SD / C 1, /2 145TC CEM7034T-I ➄ 1,378 SD /460 0 A 1, TC CM7034T-I ➄ 1,056 SD / D 1, TC CEM7037T-I ➄ 1,461 SD / A 1, TC CM7037T-I ➄ 1,140 SD / D 1, TC CEM7042T-I ➄ 1,645 SD / A 1, TC CM7042T-I ➄ 1,336 SD / D 1, TC CEM7044T-I ➄ 1,989 SD / A 1, TC CM7044T-I ➄ 1,607 SD / D 1, /2 213TC CEM7047T-I ➄ 2,333 SD / A 1, TC CM7047T-I ➄ 1,862 SD / D 1, TC CEM7170T-I ➄ 2,838 SD / A 1, TC CM7170T-I ➄ 2,202 SD / D 1, TC CEM7054T-I ➄ 4,694 SD / A 1, TC CM7054T-I ➄ 3,843 SD / D 1, TC CEM7056T-I ➄ 5,564 SD / A 1, TC CM7056T-I ➄ 4,464 SD / D 1, TC CEM7058T-I ➄ 6,813 SD / A 1, TC CM7058T-I ➄ 5,555 SD / D 1, TC CEM7060T-I ➄ 7,907 SD / A 1, TC CM7060T-I ➄ 6,279 SD / D 1, TC CEM7062T-I ➄ 10,547 SD / A 1, TC CM7062T-I ➄ 8,488 SD / D 1, TC CEM7064T-I ➄ 11,993 SD / A 1, TC CM7064T-I ➄ 9,600 SD / D 1, 19 Cast Iron These motors expel condensation better than standard explosion proof designs. They are recommended for applications such as fuel transfer terminals and fuel truck loading facilities where motors may run intermittently, applications where explosion-proof motors are installed outdoors exposed to the environment, and may not be operated for extended periods of time. These explosion-proof motors are not suitable for use with adjustable speed drives. Inverter duty explosion-proof motors must be used. See page 232. HVAC Super-E Industrial Pump Commercial 113

14 Super-E Industrial Drill Rig Duty, Three Phase, 1.15 Service Factor Explosion Proof Cast Iron These motors expel condensation better than standard explosion proof designs. They are recommended for applications such as fuel transfer terminals and fuel truck loading facilities where motors may run intermittently, applications where explosion-proof motors are installed outdoors exposed to the environment, and may not be operated for extended periods of time. These explosion-proof motors are not suitable for use with adjustable speed drives. Inverter duty explosion-proof motors must be used. See page 232. C-Face, Footless 1/2 56C VM7006-I ➄ 756 SD / C 1, 19 3/4 56C VM7010-I ➄ 840 SD / C 1, C VM7014-I ➄ 882 SD / C 1, TC VM7014T-I ➄ 952 SD / B 1, /2 56C VM7034-I ➄ 950 SD / C 1, TC VM7034T-I ➄ 1,026 SD / B 1, TC VM7037T-I ➄ 1,110 SD / B 1, TC VM7042T-I ➄ 1,423 SD / B 1, TC VM7044T-I ➄ 1,733 SD / B 1, /2 213TC VM7047T-I ➄ 2,006 SD / B 1, TC VM7170T-I ➄ 2,433 SD / B 1, 19 Pump Commercial HVAC Drill Rig Duty,, C-Face, 1.15 Service Factor, Foot Mounted 1/3 thru 1 56C Applications: Pumps, blowers, valves and other applications in petro-chemical industry needing, Division I, Class I, Group C & D approval. Features: Corrosion resistant finish, breather drain, labyrinth seal on output shaft. UL approved conduit box, 1.15 service factor, UL and CSA approved for Class I, Group C & D. These motors expel condensation better than standard explosion proof designs. They are recommended for applications such as fuel transfer terminals and fuel truck loading facilities where motors may run intermittently, applications where explosion-proof motors are installed outdoors exposed to the environment, and may not be operated for extended periods of time. These explosion-proof motors are not suitable for use with adjustable speed drives. Inverter duty explosion-proof motors must be used. See page /3 56C CL5001-I ➄ 803 K / C 1/2 56C CL5004-I ➄ 804 K / C 3/4 56C CL5007-I ➄ 858 K / C 1 56C CL5023-I ➄ 925 K / C 114

15 ATEX Directive 94/9/EC Explosion Proof 1 thru T thru 449T.75 thru 373 kw IEC 112M thru 280H NEW! Dual Protection ATEX Motor with Increased Safety conduit box, 360T, fl ange mounted. Applications: Baldor offers a wide variety of Custom Explosion Proof motors for use outside the US market where other than UL certifi cation is required. Baldor s ATEX motor certifi cation capabilities meet the Atmospheric Explosive directive (ATEX 94/9/EC) required on all equipment used in hazardous locations within the European market. Baldor uses SIRA as our 3rd party approval body for ATEX certifi cation. Baldor ATEX motors also carry the IECEx certifi cation to satisfy the broader international market. Features: Rugged Cast Iron frame, endplates, conduit box and fan cover, Super-E Premium designs (IEC IE3), 1.15 Service Factor, Usable on Sine wave and Inverter power, CE compliant. ATEX APPROVED MOTORS It is important to have a good understanding of ATEX terminology to be able to determine which Baldor ATEX certifi ed motor is right for your application. This terminology is different from those used by UL and should not be mixed with UL terms in specifi cations or quotes. Specifi c ATEX markings are required to certify that a motor may be used in specifi c potentially explosive environment. Typical ATEX markings include: Super-E Industrial European Community marking of explosion protection II 3 G, Ex na IIC T3 Gc, 0518 CE marking with SIRA s 3rd party approval body Identifi cation Equipment Protection Level (EPL): Equipment Group: I = Mining II = Surface Industry Equipment Category: 1 = Zone 0 or 20 2 = Zone 1 or 21 3 = Zone 2 or 22 Explosive Atmosphere: G = Gas/Vapor D = Dusts Explosion Protection: Exd = Flameproof Exe = Increased Safety ExnA = Non-Sparking Extb = Dust Ignition Proof G = Gas or D = Dust a / b / c = Zones 0 / 1 / 2 respectively Temperature Code: Maximum surface temperature of the motor T1 T2 T3 T4 T5 T6 450 C 300 C 200 C 135 C 100 C 85 C Apparatus Group: II = Gases/Vapor III = Dust A/B/C = level of risk with C being the highest risk BALDOR ATEX CAPABILITIES MATRIX - Group II (Surface Industry Applications) Environment Explosion Protection Max. HP (kw) Explosive Gas Environments (G) Explosive Dust Environments (D) Dual Protection Gas & Dust Environments (G/D) Increased Safety Exd (Flameproof) Zone 1 ExnA (Non-Sparking) Zone 2 Extd (Dust Ignition Proof ) Zone HP (373kW) 450HP (335kW) 500HP (373kW) (IEC) 180T 449T (112M-280M) 180T 4412T (112M 280H) 180T 449T (112M-280M) Max. Apparatus Group Temp Code 1,000 volts IIA & IIB T3, T4 & T5 2,300 volts IIA, IIB & IIC T2, T3 & T4 1,000 volts IIIA, IIIB & IIIC T3, T4 & T5 Baldor motors marked Extb for Zone 21 may be additionally labeled suitable for Zone 22 (EPL Dc) Baldor ATEX motors can be dual labeled for Exd (Flameproof) and Extd (Dust Ignition Proof), Zones 1, 21 to meet the most hazardous explosive atmosphere applications. Exd motors can be supplied with an Increased Safety conduit box separately labeled Exe Ambient Temp. ( C) -20 to +40 (+65 Max) -20 to +40 (-30 Min) -20 to +40 (+65 Max) Baldor takes pride in tailoring our custom motors to fi t our customer s specifi c requirements. For a full range of available options, pricing and availability contact your local Baldor Sales Representative. Pump Commercial HVAC 115

1/4 thru 300 Hp NEMA 48 thru 449TY. List Price. Mult. Sym. C Dim. Single Phase

1/4 thru 300 Hp NEMA 48 thru 449TY. List Price. Mult. Sym. C Dim. Single Phase Single and Three Phase, Foot Mounted Explosion Proof 1/4 thru 300 48 thru 449TY Applications: Ideal for use where hazardous fumes or dust may be present. Features: U.L. and CSA approved for Class I, Group

More information

200 & 575 Volt Motors. 200 Volt, Three Phase, TEFC, Foot Mounted. 1/2 thru 50 Hp NEMA 56C thru 326T

200 & 575 Volt Motors. 200 Volt, Three Phase, TEFC, Foot Mounted. 1/2 thru 50 Hp NEMA 56C thru 326T Farm Duty 200 Volt, TEFC, Foot Mounted 200 & 7 Volt 1/2 thru 0 6C thru 26T Applications: Pumps, fans, compressors, blowers, machine tools, conveyors and many other applications requiring 200 volt power.

More information

1/2 thru 50 Hp NEMA 56C thru 326T

1/2 thru 50 Hp NEMA 56C thru 326T 200 Volt, TEFC, Foot Mounted Cast Iron Foot Mounted 200 & 7 Volt 1/2 thru 0 6C thru 26T Applications: Pumps, fans, compressors, blowers, machine tools, conveyors and many other applications requiring 200

More information

Catalog. Brochure. Baldor explosion proof AC and DC Motors. Catalog

Catalog. Brochure. Baldor explosion proof AC and DC Motors. Catalog Brochure Baldor explosion proof AC and DC Motors We provide motors, generators and mechanical power transmission products, services and expertise to save energy and improve customers processes over the

More information

Applications: Pumps, fans, compressors, blowers, machine tools, conveyors and many other applications requiring 200 volt power.

Applications: Pumps, fans, compressors, blowers, machine tools, conveyors and many other applications requiring 200 volt power. 200 Volt, TEFC, Foot Mounted 1/2 thru 0 200 & 7 Volt 6C thru 26T Applications: Pumps, fans, compressors, blowers, machine tools, conveyors and many other applications requiring 200 volt power. Features:

More information

1/3 thru 2 Hp NEMA 56J. Aprx. Wt. (lb) Mult. Sym. C Dim. Foot Mounted. Footless

1/3 thru 2 Hp NEMA 56J. Aprx. Wt. (lb) Mult. Sym. C Dim. Foot Mounted. Footless General Super-E Jet Pump,, TEFC Pump 1/ thru 2 6J Applications: Residential and industrial pumps, swimming pool pumps, etc. Features: Diecast aluminum end plates with machined steel bearing seat insert.

More information

Motors and drives for applications in explosive atmospheres

Motors and drives for applications in explosive atmospheres Motors and drives for applications in explosive atmospheres Certification. Diligence. Reliability. Safety. Everything counts Operating processes in explosive (Ex) atmospheres requires the right mix of

More information

Single and Three Phase General Purpose Motors

Single and Three Phase General Purpose Motors Single and Three Phase Single phase and three phase general purpose motors are designed to meet or exceed the energy efficiency requirements of the United States, Canada and Mexico for general purpose

More information

Pump Motors. Information. General. Single Phase Motors. Industrial Motors. General Purpose. Severe Duty Motors

Pump Motors. Information. General. Single Phase Motors. Industrial Motors. General Purpose. Severe Duty Motors General Industrial Pump HVAC Farm Duty 8 Pump From industrial wastewater to fire suppression systems or commercial pools, Baldor Reliance pump motors provide value by increasing reliability and reducing

More information

VALIADIS S.A. HELLENIC MOTORS

VALIADIS S.A. HELLENIC MOTORS Explosion proof motors MAK 56-250 (MAKe 63-250) series Groups IIB and IIC Ex db / Ex db e (EPL) executions Gb or Ex tb IIIC (EPL) Db II 2 G, II 2D, 2GD SAFETY INSTRUCTIONS Safety Instructions MAK and MAKe

More information

Super-E Premium Efficient Motors

Super-E Premium Efficient Motors Super-E Premium Efficient Motors Why Baldor? Customer Preference 20% 1985 50% 1990 90% 2000 94% 2003 95.5% 2007 The percentages shown reflect results of studies conducted in which Baldor was chosen as

More information

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx) INSTRUCTION MANUAL (ATEX / IECEx) BExBG10D-P and BExBG15D-P Flameproof Xenon Beacons For use in Flammable Gas and Dust Atmospheres BExBG10D-P / BExBG15D-P 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE

More information

Ex e, ia Junction boxes TNCN. Features

Ex e, ia Junction boxes TNCN.   Features TNCN Features The TNCN/TNCC range comprises many standard sizes of enclosure manufactured in 316L acid resistant stainless steel to give the maximum environmental protection. The main body is manufactured

More information

1/3 thru 2 Hp NEMA 56J. Mult. Sym. C Dim. Foot Mounted. Footless

1/3 thru 2 Hp NEMA 56J. Mult. Sym. C Dim. Foot Mounted. Footless Jet Pump,, TEFC 1/ thru 2 6J Pump Applications: Residential and industrial pumps, swimming pool pumps, etc. General Features: Diecast aluminum end plates with machined steel bearing seat insert. All threaded

More information

SERIES R - MD MOR & GOR

SERIES R - MD MOR & GOR SERIES R - MD MOR & GOR CHARACTERISTICS OPTIONS Aluminium alloy construction Surface protection treatment (anodising, only for ATEX 2 versions) Available in monoblock execution (MOR) and with coupling

More information

Over 525 Stock Motor Ratings. The Right Pump Motor for your Application. Leadership in Premium Efficiency. 1

Over 525 Stock Motor Ratings. The Right Pump Motor for your Application. Leadership in Premium Efficiency.   1 Baldor Pump Motors Baldor Reliance is the leading supplier of Pump Motors to meet industrial and commercial applications. From industrial waste water to commercial pool pump motors Baldor Reliance pump

More information

MASSENGALE ARMATURE WORKS BALDOR MOTORS TYPICALLY IN STOCK

MASSENGALE ARMATURE WORKS BALDOR MOTORS TYPICALLY IN STOCK HP Catalog # DESCRIPTION.5 M3108.5HP,1725RPM,3PH,60HZ,56,3416M,OPEN,F1,N Features: Ball Bearings Locked drive end bearing Heavy gauge steel frame APPLICATIONS: Pumps, fans, conveyors, machine tools, gear

More information

ATEX LABELLING FOR MOTORS AND GEAR UNITS

ATEX LABELLING FOR MOTORS AND GEAR UNITS ATEX LABELLING FOR MOTORS AND GEAR UNITS EN ATEX INFORMATION GAS AND DUST COMPLETE DRIVE SOLUTIONS FROM A SINGLE SOURCE RELIABLE n Reliable products n Coordinated components n NORD's own development and

More information

Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS Government Approved Test Laboratory (Previously AIA) Reg No: 1999/027771/07 Equipment: Manufacturer: Type: ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION

More information

HVAC Motors Three Phase, TEFC, Foot Mounted, with Internal AEGIS

HVAC Motors Three Phase, TEFC, Foot Mounted, with Internal AEGIS 1 1 1/2 2 3 5 7 1/2 230/460 Volt HVAC TEFC, Foot Mounted, with Internal AEGIS 1 thru 100 56 thru 405T Bearing Protection Ring 10 15 20 25 30 40 50 3600 56 EM3545-G 773 K 12.23 33 77 230/460 1.4 143T EM3546T-G

More information

Definite Purpose Motors. Three Phase, Two Speed, TEFC, Foot Mounted. 3/4 thru 25 Hp NEMA 56 thru 324T

Definite Purpose Motors. Three Phase, Two Speed, TEFC, Foot Mounted. 3/4 thru 25 Hp NEMA 56 thru 324T Unit Handling Brake 200 & 575 Volt IEC & Controls DC 158 Two Speed, TEFC, Cast Iron 3/4 thru 25 56 thru 324T Applications: Fans, blowers, machine tools, hoists, conveyors, pumps. Features: Designed for

More information

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx) INSTRUCTION MANUAL (ATEX / IECEx) BExBGL2D LED BEACON For use in Flammable Gas and Dust Atmospheres BExBGL2D 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT OPEN WHEN ENERGIZED POTENTIAL

More information

NEW Explosion protection

NEW Explosion protection Standard gear units / standard gearmotors according to ATEX and IECEx EDRE motors meet the efficiency class according to IEC 60034-30 making them suitable for use worldwide Compliance with efficiency levels

More information

THREE PHASE MOTORS RIGID BASE GENERAL PURPOSE Rigid Base

THREE PHASE MOTORS RIGID BASE GENERAL PURPOSE Rigid Base THREE PHASE MOTORS DRIP-PROOF RPM 60 HP Hz 1/4 1725 1725 S56 100027 $246 A 16 208-230/460 1.4 58.0 9.24 1/3 3450 48 101447 251 A 14 208-230/460 1.4 68.0 9.00 1725 48 100446 266 A 17 208-230/460 1.6 64.3

More information

A Full Line of Low Voltage IEC Motors In-Stock

A Full Line of Low Voltage IEC Motors In-Stock BUILT TO PERFORM WHERE OTHERS FAIL A Full Line of Low Voltage IEC Motors In-Stock Distributed by Elektrim Motors Authorized Distributor: www.elektrimmotors.com or call 855-Go-Elektrim 0.08-220HP Low Voltage

More information

BROCHURE. Low voltage motors and drives for applications in explosive atmospheres

BROCHURE. Low voltage motors and drives for applications in explosive atmospheres BROCHURE Low voltage motors and drives for applications in explosive atmospheres 2 ABB LOW VOLTAGE MOTORS AND DRIVES FOR APPLICATIONS IN EXPLOSIVE ATMOSPHERES ABB LOW VOLTAGE MOTORS AND DRIVES FOR APPLICATIONS

More information

MAX-E1 FAMILY NEMA PREMIUM EFFICIENCY

MAX-E1 FAMILY NEMA PREMIUM EFFICIENCY MAX-E1 FAMILY NEMA PREMIUM EFFICIENCY TYPE AEHE, AEHH8N, AEHH8NCF, AEUH8NDC Effective 05-01-13 Supercedes 08-01-11 APPLICATIONS: Fans & Blowers Compressor Any Severe Duty/ Petro-Chem/ Pumps Mixers Pulp

More information

Explosion and flame-proof cast iron electric motors

Explosion and flame-proof cast iron electric motors Explosion and flame-proof cast iron electric motors EEx-d, EEx-de, IIB, IIC II, 2G IP55 II, 2G&D IP66 T4, T5, T6 Frame size 56 to 160 3 phases Voltage 230/400 V 50Hz Voltage 265/460V 60Hz Types of mounting

More information

5 Year Warranty Premium Efficiency, TEFC Enclosure Inverter Duty Motors Corona Resistant Magnet Wire CSA Certified, UL, CE NEMA MG1 (2003) Part 31,

5 Year Warranty Premium Efficiency, TEFC Enclosure Inverter Duty Motors Corona Resistant Magnet Wire CSA Certified, UL, CE NEMA MG1 (2003) Part 31, 5 Year Warranty Premium Efficiency, TEFC Enclosure Inverter Duty Motors Corona Resistant Magnet Wire CSA Certified, UL, CE NEMA M1 (003) Part 31, DefinitePurpose Inverter Fed Motors Inverter Shield TM

More information

Explosion and flame-proof single phase electric motors

Explosion and flame-proof single phase electric motors Explosion and flame-proof single phase electric motors EEx-d, EEx-de, IIB, IIC II, 2G IP55 II, 2G&D IP66 T4, T5, T6 Frame size 56 to 112 Single phase Voltage 230 50Hz Voltage 265 60Hz Types of mounting

More information

Explosion Proof Motors

Explosion Proof Motors SINGLE-PHASE Foot Mount...A-110 C-Face Foot Mount...A-110 THREE-PHASE Foot Mount...A-112 C-Face Foot Mount...A-116 C-Face Footless...A-117 JP Foot Mount...A-117 ATEX Foot Mount...A-120 A-108 Fractional

More information

Comfort. Sewage Treatment Plants. Petrochemical Facilities, Oil Rigs. Unattended Pumping Stations. Chemical Storage and Handling Facilities

Comfort. Sewage Treatment Plants. Petrochemical Facilities, Oil Rigs. Unattended Pumping Stations. Chemical Storage and Handling Facilities 3-35 kw 10,200-119,420 Btuh 208 to 600 Volts 1 or 3 Phase Meets NEC, OSHA and UL Requirements ATEX and GOST Models Available Refer to WR-80EP in the Controls section. F-4 Description Type is designed to

More information

Definite Purpose Motors. Three Phase, Two Speed, TEFC, Foot Mounted. Applications: Fans, blowers, machine tools, hoists, conveyors, pumps.

Definite Purpose Motors. Three Phase, Two Speed, TEFC, Foot Mounted. Applications: Fans, blowers, machine tools, hoists, conveyors, pumps. Three Phase, Two Speed, TEFC, 1 thru 25 56 thru 324T Applications: Fans, blowers, machine tools, hoists, conveyors, pumps. Features: Lifting eye bolt mounted at top center 215T frame and larger for easy

More information

Sensor boxes SRBE Key features and product range overview

Sensor boxes SRBE Key features and product range overview Sensor boxes SRBE Sensor boxes SRBE Key features and product range overview Function Sensor boxes SRBE are used for electrical feedback and control of the position of process valves actuated using pneumatic

More information

INDEX NEMA PREMIUM EFFICIENCY

INDEX NEMA PREMIUM EFFICIENCY INDEX S EED EXC DS R TS O DAR MEE E STAN CE THREE-PHASE MOTORS - FEATURES & LIST PRICES THREE-PHASE MOTORS TEFC - Foot-Mount................... A-51 A-54 TEFC C-Flange........................ A-55 ODP

More information

CX1 ProVector Explosion-Proof Heaters

CX1 ProVector Explosion-Proof Heaters Explosion-Proof Heaters For hazardous locations heating, rely on the for the most dependable, troublefree service available. CCI Thermal Technologies Inc. manufactures explosion-proof air heaters to satisfy

More information

SECTION MOTOR REQUIREMENTS for HVAC

SECTION MOTOR REQUIREMENTS for HVAC PART 1 GENERAL 1.1 SECTION INCLUDES A. Single-phase electric motors B. Three-phase electric motors 1.2 REFERENCES SECTION 23 05 13 MOTOR REQUIREMENTS for HVAC A. ABMA 9 - Load Ratings and Fatigue Life

More information

Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06

Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06 www.atos.com Table TF040-2/E Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06 A B DHRZO-A-012/25 A B DHRZA-A-010/25 DHRZ* are

More information

High voltage flameproof induction motors The simplest solution for hazardous environments

High voltage flameproof induction motors The simplest solution for hazardous environments High voltage flameproof induction motors The simplest solution for hazardous environments We offer motors and generators, services and expertise that save energy and improve our customers processes over

More information

Premium Efficiency Exceeds Effciency Levels Mandated by CSA C390 and EPACT 92

Premium Efficiency Exceeds Effciency Levels Mandated by CSA C390 and EPACT 92 Premium Efficiency Exceeds Effciency Levels Mandated by CSA C390 and EPACT 9 Crown Triton TM Series Premium Efficiency Motors Experience Combined with Technology yundai Induction Motors use Finite Element

More information

GOVERNMENT APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

GOVERNMENT APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS Reg No: 1999/027771/07 (Pty) Ltd 7 Spanner Rd / PO Box 467 Olifantsfontein 1665 Tel: +27 (11) 316 4601 Fax: +27 (11) 316 5670 E-mail: admin-mgr@explolabs.co.za GOVERNMENT APPROVED TEST LABORATORY IN TERMS

More information

Terminal Boxes TNCN. Explosion protection Marking

Terminal Boxes TNCN. Explosion protection Marking Terminal boxes TNCN Terminal Boxes TNCN The TNCN range comprises many standard sizes of enclosures manufactured in stainless steel 316L for maximum environmental protection. The main box is manufactured

More information

VEM3546 1HP 1800RPM 3PH 56C Tefc Motor. Features. Description. Manufacturer Information

VEM3546 1HP 1800RPM 3PH 56C Tefc Motor. Features. Description. Manufacturer Information 3804 outh treet 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 VEM3546 1HP 1800RPM 3PH 56C Tefc Motor Baldor Electric CO. Catalog Number Manufacturer Description Weight per unit Product

More information

Three Phase Modifiable NEMA Horizontal Motors Accessories and Modifications

Three Phase Modifiable NEMA Horizontal Motors Accessories and Modifications 1. Altitude Standard motors are designed for 3,300 feet altitude and 40 C ambient temperature. Atmospheric conditions at higher altitudes inhibit the motor s ability to dissipate heat, resulting in an

More information

Flameproof Enclosures

Flameproof Enclosures Flameproof Enclosures The range comprises many standard sizes of enclosures manufactured in stainless steel 316L and/or in painted carbon steel. The enclosures allow for utilization of standard electrical

More information

General Purpose Three Phase Motors TEFC (IP55) High Efficiency. Standard Features

General Purpose Three Phase Motors TEFC (IP55) High Efficiency. Standard Features TM WEG W21 Severe Duty motors meet the most demanding severe duty application requirements. These TEFC motors are all cast iron construction, with enclosures rated IP55 to handle wet and dirty environments.

More information

Quick and Easy Voltage Flexibility for NEMA and Metric IEC Motors Motors are re-rated from stock models to 575V in as little as (1) business day

Quick and Easy Voltage Flexibility for NEMA and Metric IEC Motors Motors are re-rated from stock models to 575V in as little as (1) business day Elektrim 7V s Quick and Easy Voltage Flexibility for NEMA and Metric IEC s s are re-rated from stock models to 7V in as little as () business day Available 7V s: -0 HP NEMA Premium Performance Series s

More information

The Baldor Super-E. Over 1,000 Stock Motor Ratings. The Right Premium Efficient Motor for your Application. Leadership in Premium Efficiency

The Baldor Super-E. Over 1,000 Stock Motor Ratings. The Right Premium Efficient Motor for your Application. Leadership in Premium Efficiency The Baldor uper-e In the mid-70s, a southeastern tire manufacturing plant asked Baldor to increase their plant s operating efficiencies. After analyzing the efficiencies of the plant s 75 Hp motors, Baldor

More information

EXBLI & EXBSPI Series. Circuit Breaker Panelboards for Harsh and Hazardous Environments

EXBLI & EXBSPI Series. Circuit Breaker Panelboards for Harsh and Hazardous Environments EXBLI & EXBSPI Series Circuit Breaker Panelboards for Harsh and Hazardous Environments KILLARK Z A H LO C NEMA 4X O Ring Gasket Stainless Steel Tri-Lead Cover New Slide MCB Assembly Handles Padlockable

More information

Maximum operating temperature for standard motors = 110 C. Shut down temperature in case of a malfunction = 115 C.

Maximum operating temperature for standard motors = 110 C. Shut down temperature in case of a malfunction = 115 C. Section 3 Maintenance & Troubleshooting General Inspection Lubrication & Bearings Type of Grease WARNING: UL rated motors must only be serviced by authorized Baldor Service Centers if these motors are

More information

FR Series Heat Exchanger Unit Heater

FR Series Heat Exchanger Unit Heater FR Series Heat Exchanger Unit Heater FR Unit Heaters are extra heavy duty (including heavy gauge steel construction) to meet the most demanding service and long life requirements for rugged industrial

More information

MFH MOFH JMFH JMFDH NVF3 MUFH VOFD VOFC VSNC VUVS

MFH MOFH JMFH JMFDH NVF3 MUFH VOFD VOFC VSNC VUVS Solenoid coils Solenoid coils Product range overview Version Type For valve series Page/ Internet MFH MOFH JMFH JMFDH NVF3 MUFH VOFD VOFC VSNC VUVS F solenoid coil MSF VACF 3 N solenoid coil VACN-N 6 N

More information

Integral Horsepower AC Induction Motors ODP, WPI Enclosures TENV, TEAO, TEFC Enclosure Explosion Proof Installation & Operating Manual

Integral Horsepower AC Induction Motors ODP, WPI Enclosures TENV, TEAO, TEFC Enclosure Explosion Proof Installation & Operating Manual Integral Horsepower AC Induction Motors ODP, WPI Enclosures TENV, TEAO, TEFC Enclosure Explosion Proof Installation & Operating Manual 8/12 Any trademarks used in this manual are the property of their

More information

Explosion-proof Solenoids ATEX. II 2 G / II 2 D EEx dm IIC T4, T5, T6. Catalogue 8735/GB. Maximum photo

Explosion-proof Solenoids ATEX. II 2 G / II 2 D EEx dm IIC T4, T5, T6. Catalogue 8735/GB. Maximum photo Explosion-proof Solenoids II 2 G / II 2 D EEx dm IIC T4, T5, T6 Catalogue Maximum photo ATEX Explosionproof solenoids with flameproof enclosure/encapsulation "dm" According to ATEX directive 94/9/EC and

More information

Cable Glands - American Series - NEC/IEC

Cable Glands - American Series - NEC/IEC Cable Glands - 103 American Series - NEC/IEC 104 Cable Glands Explosion Proof & General Purpose Cable Gland/Connector Type 711 1 2 3 1 Unique Rear Sealing System This arrangement offers IP66, IP67, IP68

More information

YFC. Limit switch. Ex d. 24 operating head types

YFC. Limit switch. Ex d. 24 operating head types Ex d YFC Limit switch 24 operating head types - Group IIC - Zone 1, 2, 21, 22 - Aluminium alloy - Easy installation, wiring and maintenance - Durable and safe over time Fastening system Earth screw RAL735

More information

Integral Horsepower AC Induction Motors ODP, WPI Enclosures TENV, TEAO, TEFC Enclosure Explosion Proof Installation & Operating Manual

Integral Horsepower AC Induction Motors ODP, WPI Enclosures TENV, TEAO, TEFC Enclosure Explosion Proof Installation & Operating Manual Integral Horsepower AC Induction Motors ODP, WPI Enclosures TENV, TEAO, TEFC Enclosure Explosion Proof Installation & Operating Manual 8/12 Table of Contents Section 1 General Information... Overview...

More information

The Baldor Super-E. Over 1,000 Stock Motor Ratings. The Right Premium Efficient Motor for your Application. Leadership in Premium Efficiency

The Baldor Super-E. Over 1,000 Stock Motor Ratings. The Right Premium Efficient Motor for your Application. Leadership in Premium Efficiency The Baldor uper-e In the mid-70s, a southeastern tire manufacturing plant asked Baldor to increase their plant s operating efficiencies. After analyzing the efficiencies of the plant s 75 Hp motors, Baldor

More information

Small centrifugal fans made of plastic

Small centrifugal fans made of plastic Small centrifugal fans made of plastic durable application-optimised wide range of variants 2 Small centrifugal fans made of plastic Index Small centrifugal fans made of plastic HF R 75-16 D and HF R 110-18

More information

SB380. Sept Rev. A

SB380. Sept Rev. A SB380 Sept. 2010 Rev. A Features pertaining to stock line ODP TEFC C-Face CCP Power range (stock) 1 1/2-200HP 1 1/2-200HP 1 1/2-100HP 1-50HP Frame construction (Rolled Steel) 180-210 N/A 180-210 140-210

More information

WATTSAVER PREMIUM EFFICIENCY MOTORS GENERAL PURPOSE

WATTSAVER PREMIUM EFFICIENCY MOTORS GENERAL PURPOSE PREMIUM EFFICIENCY MOTORS GENERAL PURPOSE The line of premium efficiency motors is now inverter capable. LEESON s unique IRIS voltage-spike-resistant insulation system is standard at no extra cost. motors

More information

Solenoid coils VACF Type codes

Solenoid coils VACF Type codes Solenoid coils VACF Type codes VACF B B2 1A Type VACF Solenoid coil, F series Solenoid coil type A B Width 30 mm, for 8 mm armature tube Width 22 mm, for 8 mm armature tube A1 Connection pattern type A,

More information

SEWPCC UPGRADING/EXPANSION PROJECT BID OPPORTUNITY SECTION LOW-VOLTAGE AC INDUCTION MOTORS

SEWPCC UPGRADING/EXPANSION PROJECT BID OPPORTUNITY SECTION LOW-VOLTAGE AC INDUCTION MOTORS SECTION 26 20 00 LOW-VOLTAGE AC INDUCTION MOTORS SEWPCC UPGRADING/EXPANSION PROJECT PART 1 GENERAL 1.1 RELATED SECTIONS A. This section applies only when referenced by a motor-driven equipment specification.

More information

Comfort. Description. Applications

Comfort. Description. Applications Blower Heater 3-35 kw 10,236-119,420 Btuh 208, 240, 480 and 575 Volt 1 or 3 Phase Built-in Controls Description Type is designed to heat areas classified as hazardous locations to provide primary or supplementary

More information

SUPER-MAX INDUCTION MOTOR

SUPER-MAX INDUCTION MOTOR Compliance Certificate No.CC014A CSA Listed No. 1077944 SUPER-MAX INDUCTION MOTOR PREMIUM EFFICIENCY SERIES CSA Certified for Class I Division 2 Groups A, B, C, D T3C TOTALLY ENCLOSED FAN COOLED FRAME:

More information

W21 HIGH EFFICIENCY GENERAL PURPOSE MOTORS

W21 HIGH EFFICIENCY GENERAL PURPOSE MOTORS W21 HIGH EFFICIENCY MOTORS!"#$&'#(&)*"&+,-&"./&0,,12#3&4,.5&!"00&678997:;?@&ABCD7=EF=G Data subject to change without notice. PDF processed with CutePDF evaluation edition www.cutepdf.com :7BD ROLLED

More information

The Best Value in Washdown Duty Motors and Drives

The Best Value in Washdown Duty Motors and Drives The Best Value in Washdown Duty Motors and Drives Long before we invested in the people, equipment and material required to produce Baldor Reliance Washdown Duty motors and drives, we invested our time

More information

Baldor Mod Express Modification Motor Mod Express Page

Baldor Mod Express Modification Motor Mod Express Page Page No. ATEX M1 Balance... 396 M1A Dynamic Balance of Rotors M2 Bearings... 396 M2A Sealed or Double Shielded M2B Ball to Roller M2C Bearing Thermocouples M2D Bearing RTD S M2E Add Double Sealed Bearings

More information

Explosion protection. Air + combustible gas + ignition source = explosion. Air + combustible dust + ignition source = explosion

Explosion protection. Air + combustible gas + ignition source = explosion. Air + combustible dust + ignition source = explosion Ex-protection Explosion protection Valves for fluid technology for use in explosion hazard areas Explosion protection for gas, dust and mining Flameproof enclosures and intrinsic safety Solutions for all

More information

The Baldor Super-E. Over 1,000 Stock Motor Ratings. The Right Premium Efficient Motor for your Application. Leadership in Premium Efficiency

The Baldor Super-E. Over 1,000 Stock Motor Ratings. The Right Premium Efficient Motor for your Application. Leadership in Premium Efficiency The Baldor uper-e In the mid-70s, a southeastern tire manufacturing plant asked Baldor to increase their plant s operating efficiencies. After analyzing the efficiencies of the plant s 75 Hp motors, Baldor

More information

Ex-proof proportional relief valves Direct or pilot operated, without transducer - ATEX, IECEx, EAC or CULUS

Ex-proof proportional relief valves Direct or pilot operated, without transducer - ATEX, IECEx, EAC or CULUS Table FX1-/E Replaces F6-5 /E E125-16 /E Ex-proof proportional relief valves Direct or pilot operated, without transducer - ATEX, IECEx, EAC or CULUS Valve main body Cartridge Mechanical pressure limiter

More information

D2LC Series. Circuit Breaker Panelboards for Harsh and Hazardous Environments

D2LC Series. Circuit Breaker Panelboards for Harsh and Hazardous Environments D2LC Series Circuit Breaker Panelboards for Harsh and Hazardous Environments IBUTI TR HA ON DIS KILLARK Z LO C Type 4X Gasket Stainless Steel Tri-Lead Cover Bolts Spare Sealed Wires Termination at Terminal

More information

Glass Reinforced Polyester Enclosures

Glass Reinforced Polyester Enclosures 42 The GRP range comprises 16 sizes of enclosure manufactured in glass reinforced polyester (GRP). This material is highly resistant to contamination from oils, fats, aliphatic and aromatic carbohydrates,

More information

Severe duty cast iron frame motors

Severe duty cast iron frame motors Severe duty cast iron frame motors When the going gets tough, these motors keep going SIMOTICS NEMA Low Voltage Motors www.usa.siemens.com/motors Siemens SIMOTICS low voltage severe duty motors Built to

More information

K Series 3 Way Direct Acting Balanced Poppet Solenoid Valve

K Series 3 Way Direct Acting Balanced Poppet Solenoid Valve Ex d Ex m IP5 Series 3 Way Direct Acting Balanced Poppet Solenoid Valve DB2S-M2C \ Ex d IIC with Integral Stainless \ Steel Junction Box. \ Valve. \ Manual Override, Option M2. J77072S-M2 \ Ex m II NASS

More information

Product Information Packet VEM7037T-I 2 55C 1.0SFHP, C RISERPM,3

Product Information Packet VEM7037T-I 2 55C 1.0SFHP, C RISERPM,3 Product Information Packet VEM7037T-I 2 55C AMB @ 1.0SFHP,1755 75C RISERPM,3 Copyright All product information within this document is subject to ABB Motors and Mechanical Inc. copyright protection, unless

More information

IEC Frame Motors. Metric IEC Frame Motors, Three Phase, 60 Hz, 230/460 Volts thru 1.5 kw (.25 thru 2 Hp) IEC D63 thru D90L

IEC Frame Motors. Metric IEC Frame Motors, Three Phase, 60 Hz, 230/460 Volts thru 1.5 kw (.25 thru 2 Hp) IEC D63 thru D90L Brake 200 & 575 Volt & Controls DC 200 Metric, 60 Hz, 230/460 Volts B3, Foot Mounted Q Dim. 0.18 thru 1.5 kw (.25 thru 2 Hp) D63 thru D90L Applications: Replacement motors for equipment made in Europe

More information

Product Information Packet CEM7042T-I-5 3HP,1760RPM,3PH,60HZ,182TC,3632M,XPFC,F1

Product Information Packet CEM7042T-I-5 3HP,1760RPM,3PH,60HZ,182TC,3632M,XPFC,F1 Product Information Packet CEM7042T-I-5 3HP,1760RPM,3PH,60HZ,182TC,3632M,XPFC,F1 Copyright All product information within this document is subject to ABB Motors and Mechanical Inc. copyright protection,

More information

SERIES 54 Inductive Proximity Sensor

SERIES 54 Inductive Proximity Sensor SENSOR FEATURES > 2-wire DC sensor with minimum off-state current > ATEX-approval for zone 2 and zone 22 > High temp, UV, salt water resistant > Rugged metal base > IP66/67/69K > High impact protection

More information

Product Information Packet VEM7014T-I 1//.75 55C 1.0SFHP,1760//

Product Information Packet VEM7014T-I 1//.75 55C 1.0SFHP,1760// Product Information Packet VEM7014T-I 1//.75 55C AMB @ 1.0SFHP,1760//1460 75 Copyright All product information within this document is subject to ABB Motors and Mechanical Inc. copyright protection, unless

More information

Hazardous Location Enclosures INDEX. Hazardous Location Enclosures HAZ-2

Hazardous Location Enclosures INDEX. Hazardous Location Enclosures HAZ-2 Hoffman s new ZonEX ATEX-certified enclosures can be used in Zone 1- and Zone 2-rated applications throughout the world. Our NEMA Type 9 enclosures are designed for use in Class II Division 1 and 2 locations

More information

Integral Horsepower AC Induction Motors ODP, WPI Enclosures TENV, TEAO, TEFC Enclosure Explosion Proof

Integral Horsepower AC Induction Motors ODP, WPI Enclosures TENV, TEAO, TEFC Enclosure Explosion Proof Integral Horsepower AC Induction Motors ODP, WPI Enclosures TENV, TEAO, TEFC Enclosure Explosion Proof 10/14 Installation & Operating Manual MN408 Any trademarks used in this manual are the property of

More information

EJB Enclosures. ATEX II 2 G Ex d IIB+H2 T6...T3 - II 2 D Ex td A21 T85 C C IECEx Ex d IIB+H2 T6...T3 - Ex td A21 T85 C...

EJB Enclosures. ATEX II 2 G Ex d IIB+H2 T6...T3 - II 2 D Ex td A21 T85 C C IECEx Ex d IIB+H2 T6...T3 - Ex td A21 T85 C... EJB Enclosures ATEX and IECEx Zone 1 certified Explosion proof Marine grade copper-free aluminium IP66 The EJB Series is a range of explosion-proof enclosures, available in either aluminium alloy (EJB)

More information

Technical Data. Dimensions

Technical Data. Dimensions Model Number Features 40 mm flush 4-wire DC ATEX-approval for zone 2 and zone 22 S Technical Data specifications Switching element function PNP NO/NC Rated operating distance s n 40 mm Installation flush

More information

PRODUCT OVERVIEW. Baldor s mission is to be the best (as determined by our customers) marketers, designers and manufacturers

PRODUCT OVERVIEW. Baldor s mission is to be the best (as determined by our customers) marketers, designers and manufacturers PRODUCT OVERVIEW Baldor s mission is to be the best (as determined by our customers) marketers, designers and manufacturers Motors General Purpose TEFC 1/12 Hp thru 600 Hp stock, to 800 Hp custom Enclosures:

More information

HAZARDOUS AREA MOTORS

HAZARDOUS AREA MOTORS Low Voltage 3-Phase Induction Motors MAX - Ex HAZARDOUS AREA MOTORS Range 0.18kW to 560kW Totally Enclosed Fan-Cooled Cast Iron Frame Series Contents page page General Information Hazardous Area Motors

More information

IEC Frame B3 Foot Mounted / V, 3PH, 50/60 Hz Cast Iron Construction

IEC Frame B3 Foot Mounted / V, 3PH, 50/60 Hz Cast Iron Construction ATEX IEC - EExde IIC Explosion Proof IEC B3 Foot Mounted 380-415/440-480V, 3PH, 50/60 Hz Performance - Page 87 Dimensions - Page 73-74 Features: Motors comply with CENELEC/EURONORM Standards EN60079 Certified

More information

GOVERNMENT APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

GOVERNMENT APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS Reg No: 1999/027771/07 (Pty) Ltd 7 Spanner Rd / PO Box 467 Olifantsfontein 1665 Tel: +27 (11) 316 4601 Fax: +27 (11) 316 5670 E-mail: admin-mgr@explolabs.co.za GOVERNMENT APPROVED TEST LABORATORY IN TERMS

More information

Features and Benefits

Features and Benefits Features and Benefits ELECTRICAL DESIN z 1 500 HP; 2, 4, 6 pole z 3600, 1800, 1200 RPM z 3 Phase, 60 Hz, 460V z Motors can be rerated for 380, 400 and 415 VAC at 50 Hz. z Designed to meet NEMA M1, M13,

More information

Linear Valve Electric Actuator

Linear Valve Electric Actuator Linear Valve Electric Actuator www.powervalves.nl Company Profile Company Profile Sun Yeh Electrical Ind. Co., Ltd. was founded in 1986. We always strive for technical excellence, innovation and the highest

More information

Product Information Packet CEM7064T-I 50//40HP,1775//1475RPM,3PH,60//50HZ,326T

Product Information Packet CEM7064T-I 50//40HP,1775//1475RPM,3PH,60//50HZ,326T Product Information Packet CEM7064T-I 50//40HP,1775//1475RPM,3PH,60//50HZ,326T Copyright All product information within this document is subject to ABB Motors and Mechanical Inc. copyright protection,

More information

Sample Installation: Fixed Power Source (Wall) to Remote/Portable Location

Sample Installation: Fixed Power Source (Wall) to Remote/Portable Location Industrial interlocked receptacles are available in 30 through 400. Switched receptacles have mechanical linkages for added safety. Safety features include: Plugs cannot be inserted unless power is safely

More information

Table of contents. Technical informations > ATEX Page Technical informations Page Mechanically operated valves Page 13-06

Table of contents. Technical informations > ATEX Page Technical informations Page Mechanically operated valves Page 13-06 Technical informations > Table of contents ATEX Page 13-02 Technical General informations information Page 13-02 Mechanically operated valves Page 13-06 Pneumatically operated valves Page 13-06 Electrically

More information

Mid-West Instrument. Piston Type Model 220. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

Mid-West Instrument. Piston Type Model 220. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter BULLETIN NO. 220/11 (SUPERSEDES BULLETIN NO. 220/06) Mid-West Instrument Piston Type Model 220 Hazardous Locations Indicating / Non-Indicating Differential Pressure Switch or Transmitter Low cost piston

More information

Full Load Amps Model Number List 1.52/ / / / / /1.3 4/2 3.6/1.8 4/2 4.4/ / / /2.8 2.

Full Load Amps Model Number List 1.52/ / / / / /1.3 4/2 3.6/1.8 4/2 4.4/ / / /2.8 2. Variable Speed & : VAC, Hz Input Ratings (V/Hz Mode) & Enclosures (V/Hz Mode) Enclosures (Frames 2-445T) (V/Hz Mode) Enclosures (Frames 447-449T) Variable (V/Hz Mode) & Enclosures PowerMatch With All Reliance

More information

Rosemount Product Data Sheet , Rev GA Catalog FIELDBUS PROTOCOL. Hazardous Locations Certifications

Rosemount Product Data Sheet , Rev GA Catalog FIELDBUS PROTOCOL. Hazardous Locations Certifications Product Data Sheet Rosemount 3051 FIELDBUS PROTOCOL Hazardous Locations Certifications North American Certifications FM Approvals E5 Explosion-Proof for Class I, Division 1, Groups B, C, and D. Dust-Ignition-Proof

More information

Application Information

Application Information AGENCY LISTINGS UL and CSA Marathon Electric s Fire Pump and Explosion Proof motors are UL Listed. Other motor types are UL Recognized, including models with inherent overheating protection as noted (i.e.

More information

Hazardous Duty Applications

Hazardous Duty Applications Hazardous Location Hazardous Duty Plugs, Receptacles and Interlocks Hazardous Duty Plugs, Receptacles and Interlocks Hazardous Duty Applications Russellstoll Hazardous Duty Plugs, Receptacles and Interlocks

More information

c. Electric hoists and low headrooms

c. Electric hoists and low headrooms 2. Hoists & trolleys a. Manual operated b. Air operated hoists and low headrooms c. Electric hoists and low headrooms d. Trolleys 12 Manual hoists, trolley-hoists & low headrooms Capacities 250-25,000

More information

L(+) SV1 N(-) NC. Terminal Block Connections L (+) N (-) SV1 K2 K1. Refer to "General Notes Relating to Pepperl+Fuchs Product Information".

L(+) SV1 N(-) NC. Terminal Block Connections L (+) N (-) SV1 K2 K1. Refer to General Notes Relating to Pepperl+Fuchs Product Information. Type Z & Ex pz purge and pressurization system Features 100% automatic purge and pressurization system including purging, temperature and leakage control, alarming and system power Third party approvals

More information