DUCTING VOLUME CONTROL DAMPERS & RADIAL FANS

Size: px
Start display at page:

Download "DUCTING VOLUME CONTROL DAMPERS & RADIAL FANS"

Transcription

1 DUCTING VOLUME CONTROL DAMPERS & RADIAL FANS A group of :-

2 THERMOPLASTIC PP PPH PVC CPVC PVDF ECTFE tubes generally available with thickness of 3 mm PFA tubes generally available with thickness of 3mm DUAL LAMINATES DUCTING DAMPERS RADIAL FANS PP+FRP/GRP PPH+FRP/GRP PVC+FRP/GRP CPVC+FRP/GRP PVDF+FRP/GRP ECTFE+FRP/GRP PFA+FRP/GRP Material of Construction PP & HDPE up to 250 NB PVDF + FRP up to 2000 NB Complete FRP up to 2000 NB For FRP/GRP, we use the resins like Isophthalic, Bisphenol, Normal Vinylester & Super Vinylester Sizes: 25 NB to 2000 NB Tel: Website: info@likutech.com

3 INTRODUCTION TO DAMPERS The Selection Process:- Selecting the correct damper is critical to guarantee great working qualities in any wind stream framework, helping you expand vitality productivity and limit establishment costs. In any framework, the damper measurements must be suitable for the composed wind stream volume. The counseling engineer who plans a framework's ventilation work ordinarily computes damper sizes as a major aspect of the general air appropriation framework. For balancing control, the designer must pick sizes that make enough speed (and along these lines enough weight drop) to permit stable control. For segregation purposes or two-position control, the designer sizes dampers for economy, considering both the underlying expense and the continuous vitality impacts the weight drop and open damper makes. About Damper Sizes :- The building's mechanical arrangements give a rundown of required dampers. Damper sizes might be demonstrated in the floor arranges or control drawings. Choosing the control dampers includes checking the determinations and taking after the necessities, including size, flanges, blade and jamb seals, blade design, bearings, leakage requirements, opposed or parallel operation, linkages, jackshafts, and construction material. Damper sizes are generally called out using height by width on plans or schedules. Damper manufacturers by convention use width by height when placing orders. Control dampers are usually installed with the blades horizontal, so the width is the dimension in line with the blades. If the blades are vertically mounted, then thrust washers are necessary. When the blades are vertical, their weight forces the blades toward the bottom part of the frame. Thrust washers provide a low-friction surface between the blades and frame to prevent binding and damage to jamb seals. When blades are horizontal, thrust bearings are not required.

4 PARALLEL VS OPPOSED BLADE OPERATION:- Parallel blades rotate so they are always parallel to each other; therefore, at any partially open position, they tend to redirect airflow and increase turbulence and mixing within the downstream duct work or plenum. This characteristic makes them good candidates for return and outside air intake into a mixing chamber. The two dampers are often linked together (one opens and one closes) to coordinate control. Opposed blades rotate opposite each other in adjacent pairs. Air discharge through this type of damper is straighter and a bit quieter under partial-flow conditions. Opposed blade dampers are often specified where air direction control is important relative to other factors, such as within final volume control devices. The flow characteristics of parallel and opposed dampers are different; an opposed blade damper must be opened further (creating a higher modulating pressure drop) to provide the same percentage of total air volume as a parallel damper (creating a lower modulating pressure drop). When they are wide open, the pressure drop is the same for both types. BLADES:- Damper blade design varies among manufacturers. There are flat blades, triple V-groove blades, single or double layer blades, and airfoil blades. The most costly is the airfoil blade which reduces noise, has the least flow resistance, and the tightest leakage. The most common is the V-groove, which offers economy and moderate flow resistance. In northern climates, multi-layered blades with insulating cores are often used for outside air control to keep the inside surfaces from icing up. Other specialty blade types are available to cope with various conditions. It is critical to consider damper leakage when selecting dampers for cost, efficiency, and control, and to protect the duct work from environmental conditions. Low leakage or ultra-low leakage dampers incorporate a seal along the edge and the side of the blade to minimize leakage when the dampers are fully closed.

5 STANDARD CONSTRUCTION :- Fire Retardant : As per ASTM E-84 Manufacturing Std : ASME / RTP-1 / BS-4994 / ASTM / ISO 7005 Temperature : 150 C Pressure : Full Vacuum / Allowable pressure Leakage : Zero Operations : Manual, Worm gear & Motorized actuation No. DESCRIPTION QTY. MATERIAL 1. BODY 1 FRP 2. DISC 1 PP/ISO.PP/PPH/PVDF 3. SPINDLE 1 SS-304/ SS-316/ ANY MATERIAL 4. BOTTOM PIN 1 SS-304/ SS-316/ ANY MATERIAL 5. SEAL 2 EPDM/ VITON/ NEOPRENE 6. HINGLE PLATE COVER - PP/ ISO.PP/ PPH/ PVDF 7. SPINDLE BOLTS - SS-304/ SS-316/ ANY MATERIAL 8. HINGE PLATE - SS-304/ SS-316/ ANY MATERIAL 9. ACTUATOR - AS PER DETAIL BOTTOM FLANGE 1 FRP 11. FASTENERS - SS-304/ SS-316/ ANY MATERIAL 12. MANUAL OVERRIDE 1 AS PER SPECIFICATION 13. SOLENOID VALVE 1 AS PER DETAIL LIMIT SWITCH 1 AS PER DETAIL 4

Perry Fiberglass Products, Inc. FRP DAMPERS

Perry Fiberglass Products, Inc. FRP DAMPERS FRP DAMPERS 5415 Village Drive Rockledge, Florida 32955 / PHONE: 321 609 9036 / FAX: 321 609 9003 www.perryfiberglass.com ABOUT PERRY DAMPERS Perry Fiberglass has over 30 years of experience in the design

More information

Baked Enamel, Epoxy, Hi Pro Polyester, Industrial Epoxy, Kynar/Hylar (70%) Permatector. Single or Reverse Flange 8 x 6 (203 x 178)

Baked Enamel, Epoxy, Hi Pro Polyester, Industrial Epoxy, Kynar/Hylar (70%) Permatector. Single or Reverse Flange 8 x 6 (203 x 178) Application and Design The is an extremely low leakage damper designed to meet the highest standards established for commercial control dampers. The is intended for application in medium to high pressure

More information

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x in. W x 120 in. H (3658mm x 3048mm) 5 in.

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x in. W x 120 in. H (3658mm x 3048mm) 5 in. R Application and Design The is a low leakage thermally insulated damper with extruded airfoil blades. features thermally broken frame and blade to eliminate the transfer of heat or cold penetration and

More information

DAMPERS FOR COMMERCIAL & INDUSTRIAL APPLICATIONS IN HEATING, VENTILATING & AIR CONDITIONING

DAMPERS FOR COMMERCIAL & INDUSTRIAL APPLICATIONS IN HEATING, VENTILATING & AIR CONDITIONING PUB. NO. 732-3 DAMPERS FOR COMMERCIAL & INDUSTRIAL APPLICATIONS IN HEATING, VENTILATING & AIR CONDITIONING The most widely used dampers in commercial HVAC applications Control Dampers - Extruded Aluminum

More information

SECTION CONTROL DAMPERS

SECTION CONTROL DAMPERS SECTION 23 09 13.43 - CONTROL DAMPERS PART I - GENERAL 1.1 SECTION INCLUDES A. Airfoil Dampers, Heavy Duty Galvanized Steel B. Thermally Insulated Dampers, Heavy Duty Galvanized Steel C. Airfoil Dampers,

More information

Series HCD Airfoil Control Damper

Series HCD Airfoil Control Damper Series HCD Airfoil Control Damper Model: HCD-1 The Holyoake HCD-1 is a precisely made volume and pressure control device with extremely low leakage when closed, (in the range of 0.003m 3 /s at 100 Pa).

More information

Introduction to Johnson Controls Dampers

Introduction to Johnson Controls Dampers Damper and Actuator Product Guide 268.1 Damper Engineering Section Product Bulletin Issue Date 1297 Introduction to Johnson Controls Dampers For over 100 years, Johnson Controls has been the industry leader

More information

HCD-135. Industrial Control Damper. Application and Design. Ratings (see page 2 and 3 for specific limitations) Standard Construction.

HCD-135. Industrial Control Damper. Application and Design. Ratings (see page 2 and 3 for specific limitations) Standard Construction. Application and Design Model is a heavy duty industrial control damper with a flanged frame. It is designed to control airflow and provide shut off in HVAC or industrial process control systems. A variety

More information

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x 305) 5 in. (127mm) Parallel

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x 305) 5 in. (127mm) Parallel Application and Design The is a low leakage thermally insulated damper with extruded airfoil blades. features thermally broken frame and blade to eliminate the transfer of heat or cold penetration and

More information

Model SEVCD-33. Low Leakage Airfoil Control Damper. Application and Design. Ratings (See page 3 for specific limitations) Blade Operation

Model SEVCD-33. Low Leakage Airfoil Control Damper. Application and Design. Ratings (See page 3 for specific limitations) Blade Operation Application and Design The is a severe environment 316SS ultra low leakage control damper with rugged stainless steel airfoil blades designed to meet the highest standards established for commercial control

More information

VCD-23. Flange Options. Size Limitations

VCD-23. Flange Options. Size Limitations Application and Design The series is a ruggedly built low leakage control damper intended for application in low to medium pressure and velocity systems. A wide range of electric and pneumatic actuators

More information

AL-Maraj Central A/C Systems Accessories Mfg Co.

AL-Maraj Central A/C Systems Accessories Mfg Co. AL-Maraj is one of the renowned Manufacturer, Stockist and Supplier of all kinds of HVAC products, Ducting accessories, Pipe support system, Electro-mechanical and A/C Accessories in U.A.E since 2000.

More information

VC Series. Volume Control Dampers M A N U F A C T U R E R S O F A I R, F I R E A N D S M O K E C O N T R O L P R O D U C T S

VC Series. Volume Control Dampers M A N U F A C T U R E R S O F A I R, F I R E A N D S M O K E C O N T R O L P R O D U C T S V41706 VC Series Volume Control Dampers Roll formed steel blades with three material options DW144 compliant Flanged models with 65mm deep mechanically fixed casings Rectangular spigotted models with 85mm

More information

HCD-230 Industrial Control Damper

HCD-230 Industrial Control Damper Application and Design Model is a heavy duty industrial control damper with a flanged frame. It is designed to control airflow and provide shut off in HVAC or industrial process control systems. A variety

More information

Model VCD-33. Low Leakage Airfoil CONTROL DAMPER. Flange Options. Blade Operation. Size Limitations

Model VCD-33. Low Leakage Airfoil CONTROL DAMPER. Flange Options. Blade Operation. Size Limitations Application and Design The series is an ultra low leakage damper with rugged steel airfoil blades designed to meet the highest standards established for commercial control dampers. The airfoil shape reduces

More information

LOW LEAKAGE VOLUME CONTROL DAMPER

LOW LEAKAGE VOLUME CONTROL DAMPER LOW LEAKAGE VOLUME CONTROL DAMPER On Time Delivery According to Standard Customization Quality Cooperation LOW LEAKAGE VCD CATALOG REV 00 APRIL 2018 2017_04_08 ABOUT US Sharqawi Air distribution systems

More information

introduction FK Series Butterfly Valves Product Data Sheet

introduction FK Series Butterfly Valves Product Data Sheet Product Data Sheet introduction < STANDARDS > ASTM D4101-86 ASTM D1784 ASTM D3222 IPEX FK Series Butterfly Valves offer superior strength and chemical resistance in highly corrosive environments and process

More information

FBV-43. Vertical Face & Bypass Control Damper Ultra Low Leakage Aluminum Frame Construction. Application and Design. Size Limitations.

FBV-43. Vertical Face & Bypass Control Damper Ultra Low Leakage Aluminum Frame Construction. Application and Design. Size Limitations. Application and Design The is a vertical style face and bypass low leakage damper. This model is intended for application in medium to high pressure and velocity systems. Smooth profile extruded aluminum

More information

Control Dampers. Leakage Performance. Model FDNB (Opposed Blade) FDQB (Parallel Blade) Galvanized 3V Blade Control Dampers

Control Dampers. Leakage Performance. Model FDNB (Opposed Blade) FDQB (Parallel Blade) Galvanized 3V Blade Control Dampers Control s Model FDCB (Opposed Blade) FDHB (Parallel Blade) Aluminum Low Leakage Control s Frame:.081 extruded aluminum Blades:.125 extruded aluminum Bearings: bronze oilite Linkage: *concealed in frame

More information

Model VCD-18. Ratings. Blade Operation. Size Limitations. Features & Options

Model VCD-18. Ratings. Blade Operation. Size Limitations. Features & Options Application and Design The series is a general purpose, low leakage control damper intended for application in low pressure and velocity systems. atings Pressure: 2 in. wg (.5 kpa) - pressure differential.

More information

Thermal Isolation. Break

Thermal Isolation. Break Application and Design The is a low leakage thermally insulated damper with extruded airfoil blades. features thermally broken frame and blade will minimize the transfer of thermal energy and reduces condensation.it

More information

Model VCD-43 Extruded Airfoil Blade Control Damper

Model VCD-43 Extruded Airfoil Blade Control Damper Application and Design The is an extremely low leakage damper designed to meet the highest standards established for commercial control dampers. The is intended for application in medium to high pressure

More information

Model VCD-34. Low Leakage Insulated Airfoil CONTROL DAMPER. Ratings (See page 3 for specific limitations) Flange Options.

Model VCD-34. Low Leakage Insulated Airfoil CONTROL DAMPER. Ratings (See page 3 for specific limitations) Flange Options. Application and Design The Series is a ruggedly built low leakage control damper with thermally insulated blades. The is intended for application in medium pressure and velocity systems. This model also

More information

Model VCD-20. Control Damper. Application. 3V Blade. Ratings. Flange Options. Size Limitations. Blade Operation. Features and Options

Model VCD-20. Control Damper. Application. 3V Blade. Ratings. Flange Options. Size Limitations. Blade Operation. Features and Options Application The series is a general purpose control damper for applications as an automatic control or manual balancing damper with low to medium pressure and velocity systems. A wide range of electric

More information

SafidDampers SPK Description. Standard Construction SPK ( Flange Type )

SafidDampers SPK Description. Standard Construction SPK ( Flange Type ) ( Flange Type ) SPK 30-300 Description SPK 30 - Series The single and multi-leaf s with extruded aluminum airfoil blades are designed for quite, efficient and reliable air volume control in air conditioning

More information

Insulated Control Damper. 12 x 7 (305 x 178) 8 x 7 (203 x 178)

Insulated Control Damper. 12 x 7 (305 x 178) 8 x 7 (203 x 178) R Application and Design The is a low leakage thermally insulated damper with extruded airfoil blades. features thermally broken blade to eliminate the transfer of heat or cold penetration and reduced

More information

Model VCD-20V. 3V Vertical Control Damper. Application and Design. Ratings (See page 4 for specific limitations) Flange Options.

Model VCD-20V. 3V Vertical Control Damper. Application and Design. Ratings (See page 4 for specific limitations) Flange Options. Application and Design The series is a vertical blade general purpose damper for application as an automatic control or manual balancing damper. This model is intended for application in low to medium

More information

VCD-23 Low Leakage CONTROL DAMPER

VCD-23 Low Leakage CONTROL DAMPER Application and Design The series is a ruggedly built low leakage control damper intended for application in low to medium pressure and velocity systems. A wide range of electric actuators are available.

More information

EnergyShield ES. Air Control and Shut off Dampers. Dampers Controls Fancoils. Ruskin Air Management Limited

EnergyShield ES. Air Control and Shut off Dampers. Dampers Controls Fancoils. Ruskin Air Management Limited April 11 EnergyShield ES EnergyShield ES Air Control and Shut off Dampers Features Dampers suitable for systems requiring air control and low closed blade leakage characteristics. Low torque characteristics.

More information

Thermal Isolation Break. Frame Type Channel Quick Connect Single or Reverse Flange Blade Action Parallel Opposed Parallel Opposed Parallel Opposed

Thermal Isolation Break. Frame Type Channel Quick Connect Single or Reverse Flange Blade Action Parallel Opposed Parallel Opposed Parallel Opposed Application The is a low leakage thermally insulated damper with extruded airfoil blades. features broken blade which minimized the transfer of thermal energy and reduce condensation. It s also IECC (International

More information

VCD-43V. Vertical Airfoil Blade Control Damper. Application and Design. Ratings. Size Limitations. Features and Options: Pressure:

VCD-43V. Vertical Airfoil Blade Control Damper. Application and Design. Ratings. Size Limitations. Features and Options: Pressure: Application and Design is a low leakage damper with vertical blade orientation designed to meet the highest standards established for commercial control dampers. The is intended for application in medium

More information

A. Product Data: For each type of product. TLC ENGINEERING FOR ARCHITECTURE - PROJECT NO AIR DUCT ACCESSORIES

A. Product Data: For each type of product. TLC ENGINEERING FOR ARCHITECTURE - PROJECT NO AIR DUCT ACCESSORIES SECTION - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this

More information

MOTORIZED VOLUME DAMPER

MOTORIZED VOLUME DAMPER MOTORIZED VOLUME DAMPER 1 a perfect partner in performance... Our Product Ranges Dampers 1 Fire Dampers 2 Fire / Smoke Dampers 3 Volume Control Dampers 4 Motorized Control Dampers 5 Pressure Relief Dampers

More information

ARROW UNITED INDUSTRIES

ARROW UNITED INDUSTRIES IP-3R ARROW UNITED INDUSTRIES Building Tomorrow s Ventilation Today Heavy Duty Dampers Industrial, Power Plant & Commercial Applications ARROW UNITED INDUSTRIES has specialized in the design and manufacturing

More information

HVAC Control & Balancing Dampers

HVAC Control & Balancing Dampers HVAC Control & Balancing Dampers Models VCD, MBD and RBD Selection Construction Performance H* W* 1June 2017 Design and Construction Features Bearing Shaft Extension Jamb Seal Commercial Control Dampers

More information

Model VCD-40. Extruded Airfoil Blade Control Damper Narrowline Frame Construction. Application. Ratings. Flange Options.

Model VCD-40. Extruded Airfoil Blade Control Damper Narrowline Frame Construction. Application. Ratings. Flange Options. Model Application The is a low leakage high performance control damper with extruded aluminum airfoil blades. Blades are completely contained within the frame allowing the damper to be directly mounted

More information

BYV Series Butterfly Valve Product Guide FLOW CONTROL

BYV Series Butterfly Valve Product Guide FLOW CONTROL BYV Series Butterfly Valve Product Guide FLOW CONTROL 17 Q U A L I T Y S E R V I C E I N T E G R I T Y 1 OVERVIEW Engineered Hand Lever Design for Enhanced Strength and UV Performance Ergonomic Grip and

More information

2.6. Air Flow Control Valve Type PRD

2.6. Air Flow Control Valve Type PRD 2.6. Air Flow Control Valve Type PRD Page 1/10 Air Flow Control Valve, Type PRD Page 2/10 Air Flow Control Valve Type PRD Description and Design The PRD remains the air valve of choice for critical heating,

More information

Model VCD-20 3V CONTROL DAMPER

Model VCD-20 3V CONTROL DAMPER R Application and Design The series is a ruggedly built general purpose damper for application as an automatic control or manual balancing damper. This model is intended for application in low to medium

More information

ARROW INDUSTRIAL PRODUCTS

ARROW INDUSTRIAL PRODUCTS IP-2R ARROW INDUSTRIAL PRODUCTS For Applications in Industrial, Power Plant & Commercial Projects ARROW UNITED INDUSTRIES ARROW UNITED INDUSTRIES has specialized in the manufacturing of air control products

More information

Actionair Control and Shut Off Dampers

Actionair Control and Shut Off Dampers December 2003 Air/Shield (Incorporating Energy/Shield ES35 & ES36) Actionair Control and Shut Off Dampers Air/Shield Aerofoil Air Control Dampers Air/Shield Aeroseal Air Control and Shut-Off Dampers Energy/Shield

More information

introduction FE Series Butterfly Valves Product Data Sheet

introduction FE Series Butterfly Valves Product Data Sheet Product Data Sheet introduction < STANDARDS > ASTM D1784 IPEX FE Series Butterfly Valves incorporate many features of our industrial FK valve, yet the all PVC construction and EPDM liner make this valve

More information

Cyclone Custom Centrifugal Fans

Cyclone Custom Centrifugal Fans Cyclone Custom Centrifugal Fans A L P H A I R Custom Engineered Centrifugal Fans ALPHAIR s line of custom engineered centrifugal fans is ideally suited for applications that involve moving air at higher

More information

VCD-23. Low Leakage CONTROL DAMPER

VCD-23. Low Leakage CONTROL DAMPER Application and Design The series is a ruggedly built low leakage control damper intended for application in low to medium pressure and velocity systems. A wide range of electric and pneumatic actuators

More information

CONTROL SMOKE AND BALANCING DAMPERS

CONTROL SMOKE AND BALANCING DAMPERS (UK) Limited CONTROL SMOKE AND BALANCING DAMPERS 00 SERIES - UNIVERSAL F e a t u r e s Robust construction of galvanised steel, with stainless steel options Opposed or parallel blade pattern Unsealed,

More information

SECTION AXIAL HVAC FANS

SECTION AXIAL HVAC FANS SECTION 233413 - AXIAL HVAC FANS 1. PART 1 GENERAL 1.1. RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

SP Standard Profile. In Duct or Flanged to Duct Install Types OPPOSED ACTION PARALLEL ACTION. Extended Rear Flange Install Type

SP Standard Profile. In Duct or Flanged to Duct Install Types OPPOSED ACTION PARALLEL ACTION. Extended Rear Flange Install Type 1 SUBMITTAL DATA Series 1000 Air-Foil Control Damper SP Standard Profile 2" 50.8 mm In Duct or Flanged to Duct Install Types 4" 101.6 mm 6.4" 162.6 mm blades fully open 1" 25.4 mm Extended Rear Flange

More information

AMCA MEMBER. American Warming and Ventilating. A Mestek Company. Quality Air Control Dampers

AMCA MEMBER. American Warming and Ventilating. A Mestek Company. Quality Air Control Dampers AMCA MEMBER American Warming and Ventilating A Mestek Company Quality Air Control Dampers Over a century of dedication to quality products and customer satisfaction has enabled American Warming and Ventilating

More information

GRP backing flanges DIN 2501 Flange connecting dimension PN10 WORK STANDARD. GRP backing flanges made of Polyester resin.

GRP backing flanges DIN 2501 Flange connecting dimension PN10 WORK STANDARD. GRP backing flanges made of Polyester resin. GRP backing flanges DIN 2501 Flange connecting dimension PN10 1310-WN-en 06 10.2002 GRP backing flanges made of Polyester resin. D 45 e d2 d1 b1 k Flange connecting dimensions according to DIN 2501 Part

More information

Ceiling swirl diffusers

Ceiling swirl diffusers X X testregistrierung Ceiling swirl diffusers Type Horizontal swirling air discharge Adjustable blades Protective cage For high rooms, with adjustable air control blades Circular ceiling swirl diffusers,

More information

USING EXABOND TECHNOLOGY LINER PIPE

USING EXABOND TECHNOLOGY LINER PIPE LINER PIPE Inside Diameter Liner Thickness DN - Nominal diameter S 1 - Liner wall thickness d 2 - Outside diameter of liner Liner material density for PVC: 1.38g/cm 3 Liner material density for PVC-C:

More information

Discharge Air Control

Discharge Air Control Issue Date June 17, 2002 APPLICATION NOTE Discharge Air Control Discharge Air Control...2 Introduction... 2 Key Concepts... 3 Discharge Air Control Overview... 3 Design Considerations... 6 2002 Johnson

More information

Factors to consider when selecting a diverter valve

Factors to consider when selecting a diverter valve Factors to consider when selecting a diverter valve Selecting a diverter valve for your pneumatic conveying system can be a tough job, especially when you consider how many diverter valves are on the market.

More information

Product Engineering Guide

Product Engineering Guide PRIMARY FLUID SYSTEMS INC. 1050 Cooke Blvd., Burlington, ON. Canada, L7T 4A8 Tel: (905)333-8743 Fax: (905)333-8746 Toll-Free: 1-800-776-6580 www.primaryfluid.com primary@primaryfluid.com Product Engineering

More information

Motorized Fire Dampers

Motorized Fire Dampers Model : OMFD-611 (Fusible link and spring return actuator) GI steel sheet construction In accordance with UL555 & UL555S suitable for installation in walls and partitions having rating 2 Hrs. Static and

More information

AMD-42V Air Measuring Station with VCD-42V Control Damper

AMD-42V Air Measuring Station with VCD-42V Control Damper Application and Design Construction Standard Optional Frame Material Galvanized Steel - Frame Material Thickness 16 ga. (1.5mm) 12 ga. (2.7mm) 14 ga. (2mm) Frame Type 5 in. x 1 in. hat channel - Blade

More information

AMD-42 Air Measuring Station with VCD-42 Control Damper

AMD-42 Air Measuring Station with VCD-42 Control Damper Application and Design W x H Construction Standard Optional Frame Material Galvanized Steel - Frame Material Thickness External Minimum Size 16 ga. (1.5mm) Internal Single Section Maximum Size Multiple

More information

B. Fabricate in accordance with ASHRAE handbooks and SMACNA duct manuals. A. Submit in accordance with Division-1 and Section

B. Fabricate in accordance with ASHRAE handbooks and SMACNA duct manuals. A. Submit in accordance with Division-1 and Section SECTION 15910 DUCT ACCESSORIES PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of Contract including General and Supplementary Conditions, Division-1 Specification Sections,

More information

Industrial Mini Vent Sets

Industrial Mini Vent Sets Industrial Mini Vent Sets FRP Construction M I N I S E R I E S and Impellers Volume Range shut off up to 4000 (1888 l/sec) Static pressures up to 19 W.G. (4719 Pa) Industrial and Commercial Applications

More information

CONTROL DAMPERS. Models 1810 & Model Model Model 1370

CONTROL DAMPERS. Models 1810 & Model Model Model 1370 CONTROL DAMPERS CONTROL DAMPERS MODELS 1810 & 1820 MANUAL ALANCING DAMPERS STEEL Models 1810 and 1820 have been engineering and designed for manual balancing applications in low to medium pressure and

More information

Type 21 True Union Ball Valves

Type 21 True Union Ball Valves PDF Published June 27, 218 Type 21 True Union Ball Valves The Chemline Type 21 True Union Ball valve incorporates state of the art features for long term performance. This is a full port, full blocking

More information

FRP Fans: CLUB Series Performance and Technical Information

FRP Fans: CLUB Series Performance and Technical Information FRP Fans: CLUB Series 1500-7300 Performance and Technical Information Verantis Environmental Solutions Group provides solutions for most common and complex situations including repair, rebuilding, field

More information

Bulletin ACF 103 AIRFOIL CENTRIFUGAL FANS DESIGN 10A

Bulletin ACF 103 AIRFOIL CENTRIFUGAL FANS DESIGN 10A Bulletin ACF 103 AIRFOIL CENTRIFUGAL FANS DESIGN 10A Quieter, More Efficient Airfoil Fans for Commercial and Light Industrial Applications Design 10A Fans with Airfoil Wheels Fourteen Sizes to 80" Volumes

More information

AMD-33. Air Measuring Station with VCD-33 Control Damper. Application and Design. Features & Control Options

AMD-33. Air Measuring Station with VCD-33 Control Damper. Application and Design. Features & Control Options Application and Design The combines the functionality of an accurate airflow measuring station and a low leakage control damper into one compact assembly that both measures and regulates airflow volumes

More information

SB Series Wafer/Lug Butterfly Valves

SB Series Wafer/Lug Butterfly Valves SB Series Wafer/Lug Butterfly Valves Engineering Creative Solutions for Fluid Systems Since 1901 ABOUT PRATT INDUSTRIAL Pratt Industrial specializes in the design, engineering, and worldwide distribution

More information

Air Measuring Products AMD AMS IAQ

Air Measuring Products AMD AMS IAQ Air Measuring Products AMD AMS IAQ January 1 2012 Air Measuring Products Why is outside air measurement important? There are many significant benefits to monitoring outside air volumes. By measuring the

More information

VOLUME CONTROL & SHUT OFF DAMPERS SERIES 400

VOLUME CONTROL & SHUT OFF DAMPERS SERIES 400 SERIES 400 Series 900 Volume Control And Shut Off Dampers: Series 900 balancing and shut off dampers have been designed, engineered and tested, with smooth efficient operation as an important consideration.

More information

AIRODYNE CATALOGUE VOLUME CONTROL TAMPERS CONSTRUCTION / MATERIALS

AIRODYNE CATALOGUE VOLUME CONTROL TAMPERS CONSTRUCTION / MATERIALS AIRODYNE CATALOGUE VOLUME CONTROL TAMPERS CONSTRUCTION / MATERIALS Airodyne multi leaf volume control tampers have been specifically designed for use in air conditioning and ventilation system for volume,

More information

FK Series Automated Butterfly Valves Product Data Sheet

FK Series Automated Butterfly Valves Product Data Sheet Product Data Sheet introduction < STANDARDS > ASTM D1784 ASTM D3222 ASTM D4101 IPEX FK Series Automated Butterfly Valves offer superior strength and chemical resistance in highly corrosive environments

More information

Control Dampers and Fire Dampers. Volume 1 - March Insulated Control Dampers. Non-Insulated Control Dampers. Framing. Accessories.

Control Dampers and Fire Dampers. Volume 1 - March Insulated Control Dampers. Non-Insulated Control Dampers. Framing. Accessories. Insulated Control Dampers 2 Volume 1 - March 2010 6 Non-Insulated Control Dampers 8 Framing Accessories 9 Jack Shaft Steel Control Dampers Fire Dampers 10 11 Control Dampers and Fire Dampers 3900 Insulated

More information

TED50XT EXTREME TEMPERATURE THERMALLY EFFICIENT, INSULATED BLADE DAMPER

TED50XT EXTREME TEMPERATURE THERMALLY EFFICIENT, INSULATED BLADE DAMPER 3900 Dr. Greaves Rd. Kansas City, MO 64030 (816) 761-7476 FAX (816) 765-8955 APPLICATION Ruskin model TED50XT is a low leak, thermally efficient damper with insulated extruded aluminum blades specially

More information

CHAMPION WAFER CHECK VALVES SIZE RANGE 2" 72" ASME CLASS MATERIALS: IRON CARBON STEEL STAINLESS STEEL ALUMINUM BRONZE ALLOY 20 MONEL NICKEL

CHAMPION WAFER CHECK VALVES SIZE RANGE 2 72 ASME CLASS MATERIALS: IRON CARBON STEEL STAINLESS STEEL ALUMINUM BRONZE ALLOY 20 MONEL NICKEL CHAMPION WAFER CHECK VALVES SIZE RANGE 2" 72" ASME CLASS 125 2500 MATERIALS: IRON CARBON STEEL STAINLESS STEEL ALUMINUM BRONZE ALLOY 20 MONEL NICKEL CHAMPION VALVES, INC. DUAL DISC SPRING LOADED WAFER

More information

AMD-33 Air Measuring Station with VCD-33 Control Damper

AMD-33 Air Measuring Station with VCD-33 Control Damper Application and Design Construction Standard Optional Frame Material Galvanized Steel - Frame Material Thickness 16 ga. (1.5mm) 12 ga. (2.7mm) Frame Type 5 in. x 1 in. hat channel - Blade Material Galvanized

More information

SMOKE DAMPERS SMOKE DAMPERS SMOKE DAMPERS

SMOKE DAMPERS SMOKE DAMPERS SMOKE DAMPERS SMOKE DAMPERS 96 97 SD SERIES SD for Use in Dynamic Systems Types Galvanized Steel Construction as Standard.. Sleeve Type, Model: SD - 0-00. Circular Type, Model: SD - 50-00. Oval Type, Model: SD - 60-00

More information

VD-1600 Series Volume Control Dampers

VD-1600 Series Volume Control Dampers VD-1600 Series Volume Control Dampers Product Bulletin VD-1600 Code No. LIT-1201735 Issued April 2017 Refer to the QuickLIT website for the most up-to-date version of this document. Since 1885, Johnson

More information

BFV : 14 : 10 : 12 BUTTERFLY VALVE

BFV : 14 : 10 : 12 BUTTERFLY VALVE BFV : 14 : 10 : 12 BUTTERFLY VALVE Looks Like Conventional Butterfly Valve... 2 FEATURES HIGHER Cv Larger disc for larger flow Improved profile of disc provides minimum Resistance to flow BOTTOM STEM Stem

More information

SBH / SBV Sales Guide BLOWER-COILS HORIZONTAL AND VERTICAL

SBH / SBV Sales Guide BLOWER-COILS HORIZONTAL AND VERTICAL SO TOUGH, WE GUARANTEE IT. SBH / SBV Sales Guide BLOWER-COILS HORIZONTAL AND VERTICAL SBH SBV www.superiorrex.com SO TOUGH, WE GUARANTEE IT! www.superiorrex.com SBH / SBV Series: CONSTRUCTION FEATURES

More information

SERIES COOLING TOWER. MULTI-CELL HRT COOLING CAPACITY Modular Design Crossflow Type LOW NOISE SUPER LOW NOISE ENERGY SAVING SUPER LOW NOISE

SERIES COOLING TOWER. MULTI-CELL HRT COOLING CAPACITY Modular Design Crossflow Type LOW NOISE SUPER LOW NOISE ENERGY SAVING SUPER LOW NOISE TX-S SERIES COOLING TOWER MULTI-CELL 100-2000 HRT COOLING CAPACITY Modular Design Crossflow Type LOW NOISE SUPER LOW NOISE ENERGY SAVING SUPER LOW NOISE TX-S Series is an induced draft cross-flow, film

More information

ACE VALVE COMPANY LIMITED

ACE VALVE COMPANY LIMITED ACE VALVE COMPANY LIMITED Http://www.acevalve.co.kr 2013.04. ACE VALVE CATALOG 278-4 Mangdeokri, Juchonmyun, Gimhae, Gyeongnam, Korea. TEL +82--310-0 FAX +82--329-06~8 E-mail acevalve@acevalve.co.kr Homepage

More information

CONTROL DAMPERS. Model Model 1370CB. Model 1380CB. Model 1390CB B7

CONTROL DAMPERS. Model Model 1370CB. Model 1380CB. Model 1390CB B7 CONTROL DAMPERS MODEL 1380 HIGH PERFORMANCE ACKDRAFT DAMPER EXTRUDED ALUMINUM HEAVY DUTY Model 1380 is a high performance extruded aluminum gravity operated backdraft damper for use in medium to heavy

More information

Lug Style Butterfly Valve Type 578

Lug Style Butterfly Valve Type 578 Lug Style Butterfly Valve Type 58 General Size: 2 12 Outer Body: Glass-filled PP Material: PVC, CPVC, PROGEF Standard PP, ABS, SYGEF Standard PVDF Seals: EPDM, FPM, PTFE/FPM Stem: 31 Stainless steel Lugs:

More information

Rite Sized Check Valves

Rite Sized Check Valves Rite Sized Check Valves ASME Class 125 2500 1 (25mm) 60 (1500mm) A Bray High Performance Company Ritepro Ritepro Corporation, headquartered in Quebec, Canada and founded in 1963, designs and manufactures

More information

Double door, spring loaded, wafer check valve designed to protect your gas or liquid piping systems.

Double door, spring loaded, wafer check valve designed to protect your gas or liquid piping systems. Double door, spring loaded, wafer check valve designed to protect your gas or liquid piping systems. Features Light weight, versatile design, 80 to 90% lighter than conventional full-body check valves.

More information

RESILIENT SEATED BUTTERFLY VALVES. Howell Valve & Automation. Toll Free: Howellvalve.com

RESILIENT SEATED BUTTERFLY VALVES. Howell Valve & Automation. Toll Free: Howellvalve.com RESILIENT SEATED BUTTERFLY VALVES Howell Valve & Automation Toll Free: 1-888-469-3557 Howellvalve.com TABLE OF CONTENTS Description Page Index 2 Resilient Standard Features 3 ST Boot Series with BUNA-N

More information

PA Series Diaphragm Type Pneumatic Actuator

PA Series Diaphragm Type Pneumatic Actuator Operating & Maintenance Manual Please keep it safely for future reference. 1) Introduction PA-190, PA-260, PA-260x2 and PA-350x2 series, a type of unilateral single-acting pneumatic actuators manufactured

More information

Keystone CompoSeal Resilient Seated Butterfly Valves Wafer style

Keystone CompoSeal Resilient Seated Butterfly Valves Wafer style Wafer style Resilient seated butterfly valves with valve body and disc in high engineered composite material providing excellent internal and external chemical resistance. Features General application

More information

Zero Leakage Isolation Damper

Zero Leakage Isolation Damper SPECIFICATION The damper casing is formed from 3.0 mm thick sheet steel into a rigid channel section to ensure proper alignment of blades and shafts. Where circular dampers are required, additional spigot

More information

butterfly valves high performance TRIPLE OFFSET HP-TRI REV0

butterfly valves high performance TRIPLE OFFSET HP-TRI REV0 high performance EXECUTION 1st OFFSET 2nd OFFSET 3rd OFFSET The BELVEN-TRI series incorporate triple offset disc configuration. With this configuration the disc seal makes contact with body seat, only

More information

Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES. Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL

Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES. Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES Circular ceiling swirl diffusers, with manual or motorised adjustment of the

More information

Keystone CompoSeal Resilient Seated Butterfly Valves Wafer style

Keystone CompoSeal Resilient Seated Butterfly Valves Wafer style Wafer style Resilient seated butterfly valves with valve body and disc in high engineered composite material providing excellent internal and external chemical resistance Features General application Since

More information

Features. Dimensions - Materials - & Parts & Parts List List

Features. Dimensions - Materials - & Parts & Parts List List MOYGRO check valve Features Compact Design - Short face-to-face length enabling installation in restricted spaces not possible with conventional check valves. Spring Assisted Closure - Providing faster

More information

Keystone CompoSeal Resilient Seated Butterfly Valves Wafer style Sizes DN PN 10/16

Keystone CompoSeal Resilient Seated Butterfly Valves Wafer style Sizes DN PN 10/16 Wafer style Sizes DN -3 PN /1 Resilient seated butterfly valves with valve body and disc in high engineered composite material providing excellent internal and external chemical resistance. Features Patented

More information

VOLUME CONTROL DAMPER

VOLUME CONTROL DAMPER VOLUME CONTROL DAMPER On Time Delivery According to Standard Customization Quality Cooperation VCD CATALOG REV 00 APRIL 2018 2017_04_04 ABOUT US Sharqawi Air distribution systems Co. Factory, has been

More information

Cover Page - Butterfly Valves Ordering Information Design Features, 2 to 12 Design Features, 2 to 12 (continued)

Cover Page - Butterfly Valves Ordering Information Design Features, 2 to 12 Design Features, 2 to 12 (continued) DESCRIPTION Cover Page - Butterfly Vs Ordering Information Design Features, 2 to 2 Design Features, 2 to 2 (continued) Design Features, 2 to 2 (continued) Design Features, 4 to 4 CV Chart, 2 to 4 Torque

More information

HEAVY DUTY BALANCE AND CONTROL DAMPER B A L A N C E C O N T R O L SERIES

HEAVY DUTY BALANCE AND CONTROL DAMPER B A L A N C E C O N T R O L SERIES HEAVY DUTY BALANCE AND CONTROL DAMPER B A L A N C E C O N T R O L HD SERIES MANUFACTURERS OF AIR/FIRE/SMOKE CONTROL PRODUCTS Product Description and Features Introduction The HD Series Multi-Leaf Volume

More information

SafidDampers SPK Standard Construction SPK Description SPK ( Flange Type )

SafidDampers SPK Standard Construction SPK Description SPK ( Flange Type ) ( Flange Type ) SPK 30-100 Standard Construction FRAME: 160mm x 30mm x 1.5mm (16 Ga.) galvanized steel formed channel for flange connection. BLADES: 250mm max. width, 1.5mm (16 Ga.) galvanized steel. FINISH:

More information

FK Series Butterfly Valves Product Data Sheet

FK Series Butterfly Valves Product Data Sheet < STANDARDS > ASTM D4101-86 ASTM D1784 ASTM D3222 IPEX FK Series Butterfly Valves offer superior strength and chemical resistance in highly corrosive environments and process flow conditions. The special

More information

CFSD Series. Product Description

CFSD Series. Product Description COMBINATION FIRE AND SMOKE DAMPER 1-1/2 HR LEAKAGE RESISTANCE CLASS II 250 O F FILE NO: R22165 Product Description Combination Fire / Smoke dampers provide an automatic means of localizing areas of smoke

More information

For installation into ductwork

For installation into ductwork X X testregistrierung Non-return dampers Type For installation into ductwork Non-return dampers prevent unwanted airflows against the intended airflow direction when the system is not in operation Maximum

More information

I Fan Powered Terminal Unit

I Fan Powered Terminal Unit I Fan Powered Terminal Unit VARIABLE VOLUME PARALLEL FLOW Fan Powered Terminal Unit Variable volume parallel flow Product Overview Variable Volume/Parallel Flow Fan Powered Terminal Units Honeywell parallel

More information