1 Drum Pump Motors SP-280P Series Enclosure:...Open Drip Proof (IP44) Available Voltage:...SP-280P & SP-280P-V : 110V...SP-280P-2, SP-280P-2-V, SP-280P-2-NL & SP-280P-2-VNL : 220V Horsepower (Watts): (825) Amps: (varies by voltage) Insulation Class:...F2 Certification:...ETL (110V) or CE (220V) Housing Material:...Thermoplastic Polyester Resin Power Cord Length:...16 ft. (4,8 m) Power Cord Plug Type:...NEMA 5-15-P (110V) or CEE 7/7 (220V) Noise Level:...84 dba Low Voltage Release:...SP-280P-2 & SP-280P-2-V : Yes...SP-280P, SP-280P-V, SP-280P-2NL & SP-280P-2-VNL : No Thermal Overload:...Yes Variable Speed:...SP-280P-V, SP-280P-2-V, & SP-280P-2-VNL : Yes...SP-280P, SP-280P-2 & SP-280P-2NL : No Weight:...10 lbs (4,5 kg) WARNING: Not suitable for pumping flammable or combustible liquids or use in a hazardous duty environment. DATA-280P-05-17
2 Drum Pump Motors SP-ENC Series Enclosure:...TEFC (IP54) Available Voltage:...SP-ENC & SP-ENC-V : 110V...SP-ENC-2, SP-ENC-2-V, SP-ENC-2NL & SP-ENC-2-VNL : 220V Horsepower (Watts): (825) Amps: (varies by voltage) Insulation Class:...F2 Certification:...ETL (110V) or CE (220V) Housing Material:...Anodized Aluminum Power Cord Length:...16 ft. (4,8 m) Power Cord Plug Type:...NEMA 5-15-P (110V) or CEE 7/7 (220V) Noise Level:...88 dba Low Voltage Release:...SP-ENC-2 & SP-ENC-2-V : Yes...SP-ENC, SP-ENC-V, SP-ENC-2NL & SP-ENC-2-VNL : No Thermal Overload:...Yes Variable Speed:...SP-ENC-V, SP-ENC-2-V, & SP-ENC-2-VNL : Yes...SP-ENC, SP-ENC-2 & SP-ENC-2NL : No Weight:...13 lbs (5,9 kg) WARNING: Not suitable for pumping flammable or combustible liquids or use in a hazardous duty environment. DATA-ENC-05-17
3 Drum Pump Motors SP-400 Series Enclosure:...Explosion Proof (IP54) II 2G Ex d IIA T4 Available Voltage:...SP-410EX : 110V...SP-420EX : 220V Horsepower (Watts):...SP-410EX : 0.3 (230)...SP-420EX : 0.8 (600) Amps: (varies by voltage) Certification:...SP-410EX : CSA Class I, Div. I, Group D, Insulation Class B, Temp Code T3C...SP-420EX : Atex II 2G Ex d IIA T4 Housing Material:...Aluminum (Inner Housing) / Nylon (Outer Shell) Power Cord Length:...12 ft. (3,7 m) Power Cord Plug:...Not Provided Noise Level:...80 dba Thermal Overload:...No Variable Speed:...No Weight:...17 lbs (7,7 kg) NOTE: Explosion proof motor regulations require that motors be returned to the manufacturer for repair. WARNING: Pumping of flammables or combustible liquids can generate a static electric discharge, causing fire or explosion resulting in injury or death. Read and understand operating instructions before starting this unit. Follow all federal, state and local safety codes including NFPA 30 - NFPA77. Prior to connecting to air supply, install bond and ground wires and check continuity of each wire. A meter reading of one ohm or less is required for safe liquid transfer. Use only metallic drum, receiving vessel and metallic pump when pumping flammables. Air motors are not recognized under any current Underwriter s Laboratory listing program. Consult a qualified engineer for suitability for use in a hazardous area or on flammables. DATA
4 Drum Pump Motors SP-A1 Power Type:...Pneumatic Horsepower (Watts): (370) Air Consumption:...27 CFM (13 80 psi (5.51 bar) Air Inlet / Exhaust Size:...1/8" npt(f) / 1/8" npt(f) Certification:...Atex II 2 G c IIB T4 Housing Material:...Cast Steel Adapter Material:...Nylon Noise Level:...78 dba Lubrication Required:...Yes, Daily Weight: lbs (1,2 kg) II 2 G c IIB T4 WARNING: Pumping of flammables or combustible liquids can generate a static electric discharge, causing fire or explosion resulting in injury or death. Read and understand operating instructions before starting this unit. Follow all federal, state and local safety codes including NFPA 30 - NFPA77. Prior to connecting to air supply, install bond and ground wires and check continuity of each wire. A meter reading of one ohm or less is required for safe liquid transfer. Use only metallic drum, receiving vessel and metallic pump when pumping flammables. Air motors are not recognized under any current Underwriter s Laboratory listing program. Consult a qualified engineer for suitability for use in a hazardous area or on flammables. DATA-A
5 Drum Pump Motors SP-A2 Series Power Type:...Pneumatic Horsepower (Watts): (560) Air Consumption:...28 CFM ( psi (6,8 bar) Air Inlet / Exhaust Size:...1/4" npt(f) / 3/8" npt(f) Trigger Lock:...SP-A2 : No...SP-A2TL : Yes Housing / Adapter Material:...Aluminum Noise Level:...87 dba Lubrication Required:...Yes, Daily Weight: lbs (1.5 kg) WARNING: Pumping of flammables or combustible liquids can generate a static electric discharge, causing fire or explosion resulting in injury or death. Read and understand operating instructions before starting this unit. Follow all federal, state and local safety codes including NFPA 30 - NFPA77. Prior to connecting to air supply, install bond and ground wires and check continuity of each wire. A meter reading of one ohm or less is required for safe liquid transfer. Use only metallic drum, receiving vessel and metallic pump when pumping flammables. Air motors are not recognized under any current Underwriter s Laboratory listing program. Consult a qualified engineer for suitability for use in a hazardous area or on flammables. DATA-A
Centrifugal Drum Pump Motor Models: SP-410EX, SP-420EX, SP-280P, SP-ENC, SP-A1 & SP-A2
Standard Pump Standard s Drum Pumps are designed to transfer a variety of materials from 55 gallon drums and tanks. Standard Pump offers several different pumps, each designed for specific applications.
More informationOperating Instructions and Parts Manual
Operating Instructions and Parts Manual Industrial Pump Models: SP-PP, SP-PHT, SP-CPVC, SP-PVDF, SP-SS, SP-AL & SP-6600/6700 Series Pump Package Models: 9400, 9410, 9420, 9430, 9460, 9500, 9510, 9600 &
More informationHIGH VISCOSITY DRUM PUMPS
HIGH DRUM UMS BULLETIN MAY 2005 SR 800 Sanitary INDUSTRIAL & SANITARY UM SERIES Flows to 17 GM / 64 LM Max 174 psi / 12 bar Rugged construction All 316 stainless steel Choice of stater elastomers Industrial
More informationOperating Instructions and Parts Manual
Operating Instructions and Parts Manual Industrial Pump Models: SP-PP, SP-PHT, SP-CPVC, SP-PVDF, SP-7600/7700 & SP-6600/6700 Series Pump Package Models: 9400, 9420, 9430, 9500, 950, 970, 9760, 9900 & 990
More information1. Before operating the pump, read and understand these operating instructions.
Standard Pump Description Standard s Drum Pumps are designed to transfer a variety of materials from 55 gallon drums and tanks. Standard Pump offers several different pumps, each designed for specific
More information4. All Federal, State, and local safety codes should be followed.
Standard Pump Description Standard s Drum Pumps are designed to transfer a variety of materials from 55 gallon drums and tanks. Standard Pump offers several different pumps, each designed for specific
More informationPOLYPROPYLENE PUMP TUBE SP-PP SERIES
POLYPROPYLENE PUMP TUBE SP-PP SERIES * * * 0 * V-seal - Viton Pump coupling Drive shaft, " (00 mm) Discharge housing Bearing unit assembled - each Viton shielded bearings, spacer, snap ring, bearing can
More informationTABLE OF CONTENTS. General Safety Information Centrifugal Drum Pumps Motors Motor Spare Parts... 3
Operating Instructions and Parts Manual Industrial Pump Models: SP-PP, SP-PHT, SP-CPVC, SP-PVDF, SP-SS, SP-00SR & SP-00DD Series Pump Package Models: 900, 90, 90, 90, 9500, 950, 900 Series TABLE OF CONTENTS
More informationWOB-L. PISTON Pumps and Compressors. 607/668/669/688/689 Series MODELS:
WOB-L PISTON Pumps and Compressors 607/668/669/688/689 Series MODELS: Standard models available. 607CA22, 607CA32, 607CD22, 607CD32 668CE44, 668CGHI44 688CE44, 688CGHI44 669CE44, 669CHGI44 689CE44, 689CGHI44
More information4. All Federal, State, and local safety codes should be followed.
Standard Pump 02 Description Standard s Drum Pumps are designed to transfer a variety of materials from 55 gallon (200 l) drums and tanks. Standard Pump offers several different pumps, each designed for
More informationP/N: DEF-0613A. Diesel Exhaust Fluid (DEF) Pumps
P/N: DEF-0613A Diesel Exhaust Fluid (DEF) Pumps DEF Solutions Standard Pump has designed a range of unique, preconfigured DEF Pump Packages that are engineered to transfer AdBlue (AUS32) Diesel Exhaust
More informationOperating Instructions and Parts Manual Industrial Pump Models: SP-PP, SP-PHT, SP-CPVC, SP-PVDF, SP-SS, & SP-700SR & SP-700DD
Operating Instructions and Parts Manual Industrial Pump Models: SP-PP, SP-PHT, SP-CPVC, SP-PVDF, SP-SS, & SP-00SR & SP-00DD TABLE OF CONTENTS PAGE STANDARD PUMP 0 University Dr., Auburn, Georgia 00 USA
More informationExplosion Proof Electric Fan/Blower - C1D1-1/3 HP Engine - Fan Only- 50' SOOW w/ EPP Cord Cap
Explosion Proof Electric Fan/Blower - C1D1-1/3 HP Engine - Fan Only- 50' SOOW w/ EPP Cord Cap Part #: EPF-10P.3-NFK-50C Page: 1 Made in Texas The EPF-10P.3-NFK-50C from Larson Electronics is an Explosion
More informationExplosion Proof Drop Light - 12 Volt AC/DC Watt Incandescent - 25' Cord - Twist Lock Plug
Explosion Proof Drop Light - 12 Volt AC/DC - 100 Watt Incandescent - 25' Cord - Twist Lock Plug Part #: EPL-DL-12-25 Made in the USA The Larson Electronics EPL-DL-12-25 Explosion Proof Hand Lamp is U.L.
More informationPRODUCT: 1500 SERIES MOBILE EXPLOSION PROOF PAGE 1 REV "BLADE MASTER" AC-EP-SINGLE PHASE-1.5 HP OPERATING AND MAINTENANCE INSTRUCTIONS
PRODUCT: 1500 SERIES MOBILE EXPLOSION PROOF PAGE 1 REV.020112 "BLADE MASTER" AC-EP-SINGLE PHASE-1.5 HP OPERATING AND MAINTENANCE INSTRUCTIONS The "Blade Master is a high-volume, low-energy, (U.L. /C.S.A.,
More information24W Explosion Proof POE Injector - Adds Power Over Ethernet Functionality to 24V POE Equipment - 1A
24W Explosion Proof POE Injector - Adds Power Over Ethernet Functionality to 24V POE Equipment - 1A Part #: EXP-IP-POE-INJ-24V-24W Page: 1 The EXP-IP-POE-INJ-24V-24W from Larson Electronics is an Explosion
More informationModels: 8500, 8501, 8513, 8514, 8500BL, 8501BL, 8513BL, 8514BL, 8540, 8541, 8550, 8551, 8540BL, 8541BL, 8550BL & 8551BL
Standard Pump Ultra Mass High Viscosity Batch Control System Description Standard s Drum Pumps are designed to transfer a variety of materials from 55 gallon drums and tanks. Standard Pump offers several
More informationCYCLOPS Z Purge Indicator
Low cost Simple to install & use Highly reliable & maintenance free Enclosure vent is part of casing Local & remote status indicator Casing available in anodized aluminum & 316 stainless steel 12 or 24
More informationV200 Positioner. V200 P Pneumatic Positioner. V200 E Electropneumatic Positioner. Housing Material: Cast aluminium with polyester coating
V200 Positioner Housing Material: Cast aluminium with polyester coating Indicator Options: Flat pointed indicator or raised indicator (red/green or yellow/black) One housing for pneumatic or electropneumatic
More informationModel 5000 Level Controller
Features Multiple Configurations The 5000 level controller is easily configured for either reverse or direct actions for both pneumatic and electric pilot options. The pneumatic pilot is available in snap
More informationDEF / AdBlue Catalogue (Diesel PL-800A Exhaust Fluid)
DEF / AdBlue Catalogue 2018 (Diesel PL-800A Exhaust Fluid) 1 AdBlue / Urea Electric Pump Packages Electric Package with Automatic Shut-off Nozzle Maximum Discharge Pressure: 32 psi (2,2 bar) Open Drip
More informationCentrifugal medium-pressure fans fitted with multi-blade
CMP/ATEX CMP/ATEX impeller Centrifugal medium-pressure fans fitted with multi-blade with ATEX certification Centrifugal single-inlet, medium-pressure fans with casing and sheet steel impeller to work in
More informationFiltered Kitchen Supply Packaged Ventilator
Filtered Kitchen Supply Packaged Ventilator Page Introduction........................................... 2 Information............................................ 3 Specifications and Dimension Data KD................................................
More informationModel 5000 Level Controller
Features Multiple Configurations The 5000 level controller is easily configured for either reverse or direct actions for both pneumatic and electric pilot options. The pneumatic pilot is available in snap
More informationSquare Inline Fans with Multi-Directional Discharge
SQN Square Inline Fans with Multi-Directional Discharge Page Introduction............................................2 Standard Construction Features............................ 3 Specifications and Dimension
More informationCYCLOPS Z Purge Indicator
Low cost Simple to install & use Highly reliable & maintenance free Enclosure vent is part of casing Local & remote status indicator Casing available in anodized aluminum & 316 stainless steel 12 or 24
More information36" Explosion Proof High Velocity Rollback Fan CFM - 1-1/2 HP - 115/230V - C1D1 - C2D1
36" Explosion Proof High Velocity Rollback Fan - 14850 CFM - 1-1/2 HP - 115/230V - C1D1 - C2D1 Part #: EPF-RSPF-36-1.5HP-100 Page: 1 Made in the USA The EPF-RSPF-36-1.5HP-100 from Larson Electronics is
More informationCX1 ProVector Explosion-Proof Heaters
Explosion-Proof Heaters For hazardous locations heating, rely on the for the most dependable, troublefree service available. CCI Thermal Technologies Inc. manufactures explosion-proof air heaters to satisfy
More informationProduct Catalogue Industrial Pumps & Metering Systems
Product Catalogue 2017 Industrial Pumps & Metering Systems TABLE OF CONTENTS Applications 4 Pump Packages 5 Drum Pump Motors 9 Pump Tubes (PP, PPS, CPVC, PHT, PVDF) 11 Performance Curves for Centrifugal
More informationPORTABLE FLUID TRANSFER SOLUTIONS DRUM/BARREL PUMPS
PORTABLE FLUID TRANSFER SOLUTIONS DRUM/BARREL S ING SOLUTIONS AROUND THE WORLD finishthompson.com DRUM S PF SERIES TUBES PFM/PFP PFV PFS Sealless, High Performance Unique double suction impeller provides
More informationMN-06. Standardized valve series 3/2-way acc. to NAMUR, 750 Nl/min (0.762 Cv) Technical data for series. Order code MN HN-142
3/2-way Technical data for series Order code -310-HN-142 Series and function Standard coil 1) (with plug socket 28-ST-01) 141 = 12 V DC, 4.2 W 142 = 24 V DC, 4.2 W 152 = 24 V AC, 7/4 VA 156 = 115 V AC,
More informationENVIRO UNIT CES SERIES
ENVIRO UNIT CES SERIES ENVIRO UNIT FILTER BOX Commercial Kitchen Exhaust CES-ISH 1,000 to 40,000 CFM Operation The grease laden air rises from the cooking equipment into the NFPA- 96 commercial kitchen
More informationLEGENDARY PRODUCTS & CUSTOMER SERVICE PUMPS & METERS FULL LINE OF QUALITY PRODUCTS MADE IN THE USA. Look for the red label! DOING BUSINESS SINCE 1972
LEGENDARY PRODUCTS & CUSTOMER SERVICE PUMPS & METERS MADE IN THE USA FULL LINE OF QUALITY PRODUCTS Look for the red label! DOING BUSINESS SINCE 1972 Great Plains Industries is a leading manufacturer of
More informationPNEUMATIC MIXERS. Laboratory Stirrers
PNEUMATIC MIXERS Laboratory Stirrers - Laboratory clamp mount, direct drive for stirring liquids up to 400 centipoise in vessels up to 5 gallons - 1/6 hp air motor,1/4 NPS-M inlet air connection, muffler
More informationControl and Terminal Box Type A21-**-*****
e pd Control and Terminal Box Exepd GmbH i_park TAUBERFRANKEN Building 23 Becksteinerstrasse 100 97922 Lauda-Königshofen Germany Phone: ++49 (0) 9343 627055-0 Fax: ++49 (0) 9343 627055-99 Mail: info@exepd.de
More informationINSTRUCTION MANUAL (ATEX / IECEx)
INSTRUCTION MANUAL (ATEX / IECEx) BExBG10D-P and BExBG15D-P Flameproof Xenon Beacons For use in Flammable Gas and Dust Atmospheres BExBG10D-P / BExBG15D-P 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE
More informationCYCLOPS Y Purge Indicator
Low cost Simple to install & use Highly reliable & maintenance free Enclosure vent is part of casing Local & remote status indicator Casing available in anodized aluminum & 316 stainless steel 12 and 24
More informationTable of Contents. 1. Model Designation And Unit Models Guide Specifications Technical Data Performance Data 10
Table of Contents Page No. 1. Model Designation And Unit Models 1 2. Features 2 3. Guide Specifications 4 4. Standard Unit Components 5 5. Technical Data 6 6. Performance Data 10 7. Electrical Data 19
More informationModels: 8500, 8501, 8513, 8514, 8500BL, 8501BL, 8513BL, 8514BL, 8540, 8541, 8550, 8551, 8540BL, 8541BL, 8550BL & 8551BL
Standard Pump Ultra Mass High Viscosity Batch Control System Description Standard s Drum Pumps are designed to transfer a variety of materials from 55 gallon drums and tanks. Standard Pump offers several
More informationInnovation and leading technology SR120V, 180V & 240V. NEXT GENERATION Recyclers. Installation guide
SR120V, 180V & 240V NEXT GENERATION Recyclers Installation guide 2017-04-17 Table of contents SECTION 1 Page Tools required 3 Parts required 3 Un-packaging the unit 3 SECTION 2 How to install a Solvent
More informationEF SERIES MOTORS OPERATION & PARTS MANUAL
EF SERIES MOTORS OPERATION & PARTS MANUAL Models S1, S2, S3, S4 S1, S2, S3 S4 EU Declaration of Conformity Finish Thompson Inc. hereby declares that the following motors fully comply with the applicable
More informationDrum & Container Pumps Installation and Operation Manual. TP-132/150 TP-160 TP-180 TP-280 TP-360 TP-380 TP-400Ex TP-AIR 1 TP-AIR 2 TP-AIR 3 S40675
Drum & Container Pumps Installation and Operation Manual TP-3/50 TP-60 TP-80 TP-80 TP-360 TP-380 TP-00Ex TP-AIR TP-AIR TP-AIR 3 S0675 Index ITEM.............................................................................
More informationCustom Shipyard and Military Facility Products
Custom Shipyard and Military Facility Products Safety Products Designed for Special Applications Respiratory Protection, Confined Space Ventilation and Portable Area Lighting Off the Shelf Or Custom Solutions
More informationHazardous Location Enclosures INDEX. Hazardous Location Enclosures HAZ-2
Hoffman s new ZonEX ATEX-certified enclosures can be used in Zone 1- and Zone 2-rated applications throughout the world. Our NEMA Type 9 enclosures are designed for use in Class II Division 1 and 2 locations
More informationProduct Catalogue Industrial Pumps & Metering Systems
Product Catalogue 2017 Industrial Pumps & Metering Systems TABLE OF CONTENTS Applications 4 Pump Packages 5 Drum Pump Motors 9 Pump Tubes (PP, PPS, CPVC, PHT, PVDF) 11 Performance Curves for Centrifugal
More informationQUALITY MISTING PUMPS
DIRECT DRIVE TOTALLY ENCLOSED FAN COOLED 60200KH, 60201KH MISTING PUMP MANUAL INCLUDING: SPECIFICATION DATA, GENERAL SAFETY PRECAUTIONS, OPERATION, INSTALLATION, PARTS, MAINTENANCE & WARRANTY QUALITY MISTING
More informationCentro-Matic Automatic Lubrication Systems FlowMaster Hydraulic Pump
FlowMaster Hydraulic Pump High-performance FlowMaster hydraulic pumps combine rotary-driven pump motors with reciprocating pump tubes and flexible control features that perform in desert heat and arctic
More informationCYCLOPS X Purge Controller XP Version
Simple to install & use Highly reliable Enclosure purge exhaust vent is part of casing Local & remote status alarms Casing available in anodized aluminum or 316 stainless steel 115 VAC, up to 25 Amps or
More informationMN-06. Standardized valve series 3/2-way acc. to NAMUR, 750 Nl/min (0.762 Cv) Technical data for series. Order code MN HN-142
Standardized valve series 3/2-way acc. to NAMUR, 750 Nl/min (0.762 Cv) Technical data for series Order code -310-HN-142 Series and function Standard coil 1) (with plug socket 28-ST-01) 141 = 12 V DC, 4.2
More informationMODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER
MODEL MODEL FEATURES Exhaust air up to 60,116 CFM in static pressure applications up to 1 w.g. Straight-through air flow design results in maximum exhaust efficiency Motor and drives are located outside
More informationSKINNER Intrinsically Safe Series Four-Way
SKINNER Four-Way Two-Position Valves SPECIFICATIONS Mechanical Characteristics Standard Materials of Body Aluminum Seals FKM, NBR. Other diaphragm materials available upon request. Compatible Fluids Air
More informationPressure Switch SOR. Sifter ready to run: Adequate pressure to switch. Sifter not ready to run: Either loss of air pressure, or open guard.
Switch SOR SOR (TB) 1 of 1 The wiring for the pressure switch requires some explanation. Great Western sifters use the SOR pressure switch to detect a lack of pressure. Black is normally open, and red
More informationPlease use the Q & A utility to ask us any questions concerning the material being presented.
Please use the Q & A utility to ask us any questions concerning the material being presented. Please contact Brittany Socha on the chat line or email Brittany.socha@ikonixusa.com if you would like a copy
More informationMid-West Instrument. Diaphragm Type Model 240. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter
BULLETIN NO. 240/11 (SUPERSEDES BULLETIN NO. 240/06) Mid-West Instrument Diaphragm Type Model 240 Hazardous Locations Indicating / Non-Indicating Differential Pressure Switch or Transmitter Field wireable
More informationVersatility. Features. By installing the SILENT MV, you will never experience the disturbance of noisy ventilation again. Benefits
Ultra quiet and low profile helicocentrifugal in-line fans suitable for a wide range of domestic and commercial applications. Fitted with sound absorbent insulation and manufactured with an adjustable
More informationFor technical assistance call
SR30 & SR60 NEXT GENERATION Recyclers INSTALLATION GUIDE For technical assistance call 1 877 624-8202 Table of contents Page SECTION 1 Tools required 3 Parts required 3 Un-packaging the unit 3 SECTION
More informationFlame Arrester. ergil. ATEX approved. Storage Tank Protection Equipment. Model Number 300. Product Description. (Vertical, in-line, deflagration)
ATEX approved Flame Arrester (Vertical, in-line, deflagration) Model Number 300 Product Description EGIL Storagetech Model Number 300 Flame Arrester is a safety device that has a flame barrier with a large
More informationdefender-s NJZ-FEL-B Series Hazardous Locations&Explosive Atmospheres Zone1&2, Zone21&22 II 2G Ex d IIB T5 Gb II2D Ex tb IIIC 95 Max Db IP 66
defender-s NJZ-FEL-B Series Hazardous Locations&Explosive Atmospheres Zone1&2, Zone21&22 II 2G Ex d IIB T5 Gb II2D Ex tb IIIC 95 Max Db IP 66 features Defender-S explosion-proof light uses simple profile,
More informationAmphenol Cable Glands and Cord Grips Amphenol
Amphenol Cable Glands and Cord Grips 12-055-1 Amphenol Table of Contents Page Number Introduction 1 Amphenol Cable Glands 2-3 ATEX Approved Glands Featuring Elastometric Seals EX-20 4-5 EX-25 6-7 EE-30
More informationCentrifugal Filtered Supply Roof Blowers
CFS Centrifugal Filtered Supply Roof Blowers Page Introduction...................................... 2 Specifications and Dimension Data................... 3 Typical Installation................................
More informationSERIES R - MD MOR & GOR
SERIES R - MD MOR & GOR CHARACTERISTICS OPTIONS Aluminium alloy construction Surface protection treatment (anodising, only for ATEX 2 versions) Available in monoblock execution (MOR) and with coupling
More informationSeries 1. Series 1 Pressure Switch. Pressure Switches Inc. Quality Pressure Solutions. Pressure Switches 1 G 10 N Key Features.
Model 1A 1C 1G 1Z 1P 1H Inc. Series 1 Series 1 Pressure Switch High, Low, Differential & Vacuum Pressure Switch options available All Anodized Aluminum Construction Multiple s Available UL & cul Approved
More informationKnow-how makes the difference. Limit Switches
Know-how makes the difference Limit Switches With Dansk Ventil Center as your business partner, you are always guaranteed a wide and well sorted product range and a unique technical know-how Product development
More informationAUTHENTIC LIFE SAFETY PRODUCTS SINCE 1940
AUTHENTIC LIFE SAFETY PRODUCTS SINCE 1940 NEMA 4X C1D2/C2D1 INDUSTRIAL HIGH LUMEN LED EMERGENCY LIGHT DUAL-LITE.COM INNOVATIVE LED NEMA 4X C1D2/C2D1 Industrial Emergency Light The Dynamo Series offers
More informationCONTINUO. Radial centrifugal impeller. Radial centrifugal impellers dynamically balanced, according to ISO 1940 standard,
RADIAL CENTRIFUGAL FANS CBT-N Series CONTINUO Range of single inlet direct driven centrifugal fans designed for the continuous extraction of air stream up to 120ºC(1). The casings are manufactured from
More informationWALL & STAND FANS CATALOG
WALL & STAND FANS CATALOG 18 SEMI-INDUSTRIAL WALL AND STAND FANS Ideal for gyms, auditoriums, schools, churches and industrial spaces that need powerful air circulation PRODUCT INFORMATION Motor 3-speed,
More informationExplosion proof electric motor For Fuel dispensing application. Main characteristic
Ad-pe ed.2018/0 1 Explosion proof electric motor For Fuel dispensing application RAEL motori elettrici, since its inception in the late 60s, has assembled more than a million of explosion proof electric
More information12-VOLT PUMPS CHOOSING A GPI ELECTRIC GEAR PUMP
12-VOLT S CHOOSING A GPI ELECTRIC GEAR When it comes to choosing an Electric Pump, GPI makes it easy! At Great Plains Industries, we recognize the differences in the needs of our customers. EZ-8 137100-01
More informationMODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER
MEL TXD Model Features Exhaust air up to 3,400 CFM in high static pressure applications up to 1-1/4 w.g. Attractive spun aluminum exterior Direct drive units have low sound levels and quiet operation Non-overloading
More informationFlameproof Enclosures
Flameproof Enclosures The range comprises many standard sizes of enclosures manufactured in stainless steel 316L and/or in painted carbon steel. The enclosures allow for utilization of standard electrical
More informationMid-West Instrument. Piston Type Model 220. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter
BULLETIN NO. 220/11 (SUPERSEDES BULLETIN NO. 220/06) Mid-West Instrument Piston Type Model 220 Hazardous Locations Indicating / Non-Indicating Differential Pressure Switch or Transmitter Low cost piston
More information25W Explosion Proof LED Light - C1D1-2 - C2D1-2 - Surface Mount - 50' Cord w/ EXP Plug
25W Explosion Proof LED Light - C1D1-2 - C2D1-2 - Surface Mount - 50' Cord w/ EXP Plug Part #: EXHL-SFC-LE1-50C-1227-EPP Page: 1 Made in Texas The EXHL-SFC-LE1-50C-1227-EPP from Larson Electronics is an
More informationINSTRUCTION MANUAL (ATEX / IECEx)
INSTRUCTION MANUAL (ATEX / IECEx) BExBGL2D LED BEACON For use in Flammable Gas and Dust Atmospheres BExBGL2D 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT OPEN WHEN ENERGIZED POTENTIAL
More informationFR1200G / FR2400G / FR4200G / FR4400G SD1200G / Series DC Transfer Pumps
Owners Installation, Operation, and Safety Manual FR1200G / FR2400G / FR4200G / FR4400G SD1200G / Series DC Transfer Pumps FR600G Series AC Transfer Pumps 1 Tuthill Transfer Systems 8825 Aviation Drive
More informationSILENT MV Ultra Quiet In-line Fans
Ultra Quiet In-line Fans 5 IP44 2 YEAR GUARANTEE Ultra quiet and low profile helicocentrifugal in-line fans suitable for a wide range of domestic and commercial applications. Fitted with sound absorbent
More informationField IT Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters Standard Model with Booster Stage
Data Sheet Field IT Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters Standard Model with Booster Stage Reliable through well-proven concept - More than 1,000,000 units in use
More informationMultifunctional roof fans for large flows. Multifunctional roof fans, highly robust construction, for large flows
HTMH Multifunctional roof fans for large flows Multifunctional roof fans, highly robust construction, for large flows Fan: Painted galvanised sheet steel base plate Turnable impellers cast aluminium. Protection
More informationV200 Series Positioners
V200 Series Positioners In a single compact and rugged housing The V200 positioner incorporates the flexibility of converting from a pneumatic unit to several versions of an electropneumatic unit, and
More informationsupplied in Form (B) configuration. Airflow over Impeller- Motor.
CYLINDRICAL CASED AXIAL FLOW FANS COMPACT Series TCBB-TCBT (Aluminium impellers) and TCFB-TCFT (Plastic impellers) NEW VERSIONS Description The S&P Cylindrical Cased Axial Fans feature, as the name suggests,
More informationAPS & APIS ATEX AIRPOWER SWITCH BOXES FEATURES DESCRIPTION
page 1 DESCRIPTION The switch boxes are suitable for rotary actuators and are the industry leader in versatility, quality and approvals gained. Models include APS standard range with a variety of outputs
More informationAMCA Seal Assures rating of Sound and Air performance. 2 year fan housing warranty, 1 year motor warranty
MODEL FEATURES Exhaust air up to 2,800 CFM in high static pressure applications up to 1 w.g. Direct drive units have low sound levels and quiet operation Ideal for applications where space is limited Non-overloading
More informationExplosion Proof Light - Class 1 Division 2 Light - 5 hour Run Time Li-ion Battery - MADE IN THE USA
Explosion Proof Light - Class 1 Division 2 Light - 5 hour Run Time Li-ion Battery - MADE IN THE USA Part #: RUL-9-FR Page: 1 Larson Electronics LLC Made in The USA The RUL-9-FR Hazardous Area Portable
More informationCENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VQBL
CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VQBL CENTRIFUGAL UPBLAST ROOF EXHAUSTERS HIGH TEMPERATURE SMOKE EXHAUST APPLICATIONS Belt Driven Model VQBL DESIGNED AND ENGINEERED TO MEET INDUSTRY NEEDS SECTION
More informationProximity Transmitters, and Seismic Vibration Transmitters
TM016 Velocity/ Acceleration Vibration Transmitter Introduction The TM016 is a solid state loop powered transmitter which provides a 4-20mA output proportional to the machine case vibration level. The
More informationSRH2. Steam Rig Heater. Industrial Grade Heat-Exchanger Unit Heaters. CRN: 0H C 150 psig (1034 KPa)
SRH2 EAC Ex models available. Contact factory! Steam Rig Heater CRN: 0H14931.2C 150 psig (1034 KPa) Industrial Grade Heat-Exchanger Unit Heaters www.hazlocheaters.com is a manufacturer of industrial-grade
More informationQUALITY MISTING PUMPS
TOTALLY ENCLOSED DIRECT DRIVE 60030KH, 60031KH, 60050KH, 60051KH 60100KH, 60101KH, 60150KH, 60151KH MISTING PUMP MANUAL INCLUDING: SPECIFICATION DATA, GENERAL SAFETY PRECAUTIONS, OPERATION, INSTALLATION,
More informationCONSTRUCTION FEATURES AND OPTIONS
MODEL SQD & esqd MODEL FEATURES Exhaust air up to 2,8 CFM in high static pressure applications up to 1 w.g. Direct drive units have low sound levels and quiet operation Ideal for applications where space
More informationMODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER
MEL TXD MEL FEATURES Exhaust air up to 3,400 CFM in high static pressure applications up to 1-1/4 w.g. Attractive spun aluminum exterior Direct drive units have low sound levels and quiet operation Non-overloading
More informationClimate Control Products
Products Filter Fans NEMA 1 Box Fan High airflow with low noise operations makes these versatile packaged fans very popular in a wide range of applications. Reversible mounting brackets allow user to push
More informationAEROSTAT HP-N-Ex Ionising Air Blower
SIMCO (Nederland) B.V. Postbus 71 NL-7240 AB Lochem Telefoon + 31-(0)573-288333 Telefax + 31-(0)573-257319 E-mail general@simco-ion.nl Internet http://www.simco-ion.nl Traderegister Apeldoorn No. 08046136
More informationMODEL CWD DIRECT DRIVE CENTRIFUGAL SIDEWALL EXHAUSTER
MODEL CWD MODEL FEATURES Exhaust air up to 3,360 CFM in high static pressure applications up to 1 w.g. Attractive spun aluminum exterior Direct drive units have low sound levels and quiet operation Non-overloading
More informationHeating Cable. Construction
MI Mineral Insulated High Temperature A B C Constant Wattage Series Resistance Heating Cable Sets Process Temperature Maintenance to 1112 F (600 C) Maximum Exposure Temperature 1200 F (648 C) (Power Off)
More informationSpecifications. Applications Ventilation of safety cabinets (STORM 10), scrubbers, fume capture arms, filter housing, etc. (STORM 12, 14, 16).
Specifications Applications Ventilation of safety cabinets (STORM 10), scrubbers, fume capture arms, filter housing, etc. (STORM 12, 14, 16). Housings: PP* Single block strong high density UV treated and
More information...your single dedicated resource for cost-effective mine pumping solutions. For Rugged Mining Duty
...your single dedicated resource for cost-effective mine pumping solutions For Rugged Mining Duty Mine Face Dewatering Fuel Transfer Sump Transfer Muck/Slimes/Slurry Drift Dewatering Drillers Mud Dewater
More informationModel 1210C Battery Powered Pump Shown
Page 1 of 6 PRODUCT DATA SHEET 12 Volt DC Rotary Vane Pump Series 1200C Description of Included Models Available Options Safety Listings Accessories Performance Flow Curve Fluid Compatibility Dimensions
More informationPh: (07) Fax: (07) Pump Manual
sales@scintex.com.au www.scintex.com.au Ph: (07) 3137 0135 Fax: (07) 3041 0541 Pump Manual 12V 75LPM Vane Pump & Vane Pump Station SPEP12V75 & SP12VFS75 SPEP12V75 SP12VFS75 Parts List No. Part Name QTY
More information8W Explosion Proof LED Exit Sign - C1D2 - Low Voltage - End, Ceiling, Back Mount - IP54
8W Explosion Proof LED Exit Sign - C1D2 - Low Voltage - End, Ceiling, Back Mount - IP54 Part #: HAL-EXT-LE10 Buy American Compliant The Larson Electronics HAL-EXT-LE10 is a low voltage Explosion Proof
More informationPump Kits. More than just pumps
Pump Kits More than just pumps Table of Contents FLUX Pump Kits for: Acids and Alkalis 4 5 Concentrated Acids and AdBlue 6 Petroleum Products 7 Flammable Liquids 8 Universal Applications 9 99.98 % Drum
More informationMICROPUMP MAG-DRIVE GEAR PUMPS
MAG-DRIVE GEAR PUMPS REVISION # 1 DATE: 6-6-6 WETTED MATERIALS Pump housings: 316 stainless steel. Gears: PEEK. Gear shafts: 316 stainless steel. Gear shaft bearings: PEEK. Driven magnet: Totally encapsulated
More informationCentrifugal Upblast Power Roof Ventilators
INDUSTRIES AMERICAN COOLAIR CORPORATION Centrifugal Upblast Power Roof Ventilators TYPE UBCA - BELT DRIVE TYPE UDCA - DIRECT DRIVE TABLE OF CONTENTS UBCA Sizes 06 to 44 Flow rates from 229 to 29,002 CFM
More information