TABLE OF CONTENTS. General Safety Information Centrifugal Drum Pumps Motors Motor Spare Parts... 3

Size: px
Start display at page:

Download "TABLE OF CONTENTS. General Safety Information Centrifugal Drum Pumps Motors Motor Spare Parts... 3"

Transcription

1 Operating Instructions and Parts Manual Industrial Pump Models: SP-PP, SP-PHT, SP-CPVC, SP-PVDF, SP-SS, SP-00SR & SP-00DD Series Pump Package Models: 900, 90, 90, 90, 9500, 950, 900 Series TABLE OF CONTENTS PAGE General Safety Information... Centrifugal Drum Pumps... Motors... Motor Spare Parts... Drum Pump Tubes and Pump Packages... Operation & Maintenance... 0 Pump Tube Spare Parts... Progressive Cavity Drum Pumps... Motors... Motor Spare Parts... SP-00SR Series... SP-00DD Series.... Maintenance... Pump Tube Spare Parts... 5 Hazardous Duty Environments.... Warranty... (OIPMI0) STANDARD PUMP 50 University Drive, Auburn, Georgia 00 USA TOLL FREE 55 Phone Fax info@standardpump.com

2 Standard Pump Operating Instructions and Parts Manual (OIPMI0) Standard Drum Pumps Description Standard s Drum Pumps are designed to transfer a variety of materials from 55 gallon drums and tanks. Standard Pump offers several different pumps, each designed for specific applications. Before operating, please confirm that the pump s materials of construction are suitable for the application. Unpacking Cartons should be handled with care to avoid damage from dropping, etc. After unpacking, inspect carefully for any damage that may have occurred during transit. Check for loose, damaged or missing parts. General Safety Information The responsibility for safe assembly, installation, and operation ultimately rests with the operator. Read and understand ALL safety precautions and operating instructions before operation. Careless pump operation can result in serious injury.. Before operating the pump, read and understand these operating instructions.. The operator should wear suitable protective clothing including the following: face mask, safety shield or goggles, gloves, apron, and safety shoes.. Before operating, verify the materials being pumped are compatible with the pump s wetted components.. All Federal, State, and local safety codes should be followed. Centrifugal Drum Pumps MOTOR SPECIFICATIONS 5. Verify that the motor voltage corresponds to proper electrical supply.. Before plugging motor into power supply, make sure the motor switch is in the OFF position. For Air Motors ensure inlet valve is closed before attaching air line.. Before operation, confirm all pump connections are properly tightened.. First pump clean water in order to familiarize yourself with the pump s operation, flow rate, discharge pressure and motor speed. 9. Before starting the pump, confirm the discharge hose is securely fastened to the receiving vessel in order to prevent splashing. 0. Never leave pump unattended during operation.. Do not submerge the motor in any liquid.. When finished using the pump, flush the pump by pumping water or an appropriate cleaning solution. Do not use flammable or combustible cleaning solutions.. Never carry the motor by the power cord.. Never store pump in container. Always rinse pump thoroughly and hang on wall bracket or ensure pump tube is stored in an upright and vertical position. When pumping flammable or combustible products or operating in a hazardous duty environment, the SP-SS Series Pump must be used in conjunction with an explosion proof motor. Please contact the factory or an authorized distributor with any questions regarding this matter. Model Voltage Amps Watts HP Phase Hz Enclosure Variable Explosion Air Consumption Airline Size Speed Proof Inches (mm) SP-ODP 0V ODP N N N/A N/A SP-ODP- 0V ODP N N N/A N/A SP-0P 0V ODP (IP) N N N/A N/A SP-0P-V 0V ODP (IP) Y N N/A N/A SP-0P- 0V ODP (IP) N N N/A N/A SP-0P--V 0V ODP (IP) Y N N/A N/A SP-ENC 0V TEFC (IP5) N N N/A N/A SP-ENC-V 0V TEFC (IP5) Y N N/A N/A SP-ENC- 0V TEFC (IP5) N N N/A N/A SP-ENC--V 0V TEFC (IP5) Y N N/A N/A SP-A N/A N/A N/A N/A N/A Y Y cfm (0, L/sec) PSI (, Bar) or greater SP-A Series N/A N/A N/A N/A N/A Y Y CFM (, L/sec) PSI (, Bar) or greater The speed control switch should not be used as the main ON/OFF switch. Using the speed control switch in this manner causes excessive wear to the potentiometer and may result in premature failure. The use of the speed control switch does not cut power to the motor and inadvertent activation could result in injury or death if the motor is activated when not properly attended and secured. (Only applies to SP-0P and SP-ENC Series)

3 Standard Pump Operating Instructions and Parts Manual SP-ODP SERIES MOTOR SPARE PARTS 5 9 ITEM DESCRIPTION PART 5 9 Motor assembly 0-0V Motor assembly 0-0V Overload switch.5 amp, 0-0V 5 amp, 0-0V Motor coupling Case left Actuator switch Rocker pin Case right Screw Power cord w/ strain relief & plug 0-0V 0-0V LVR

4 Standard Pump Operating Instructions and Parts Manual (OIPMI0) SP-0P SERIES MOTOR SPARE PARTS ITEM DESCRIPTION PART A 5 9A 9B Motor cover Switch housing Switch housing for variable speed, includes potentiometer 0-0V 0-0V Switch cover Lock washer Lower housing Wave washer Ball bearing Screw for plastic housing Screw for 0-0V Screw for 0-0V Ground screw Gasket, 0-0V Gasket, 0-0V Earthing lead Lead Screw Ball bearing Motor coupling Power cord w/strain relief & plug 0-0V 0-0V Hexagon nut Armature 0-0V 0-0V Stator 0-0V 0-0V Guide disc Rod connector Pressure spring Brush holder Carbon brush 0-0V 0-0V Motor housing, plastic Star washer Fan Overload switch,.5 amp 0-0V 5 amp 0-0V low voltage release EMI Filter Repair kit 0-0V (includes PN s & () 509) Repair kit 0-0V (includes PN s & () 0) P LVR LVR P 5 5 0LVR SP-0P Series motor should not be used to pump flammables.

5 Standard Pump Operating Instructions and Parts Manual SP-ENC SERIES MOTOR SPARE PARTS ITEM DESCRIPTION PART 5 9 9A 0 5 A B Motor cover Screw Armature 0-0V 0-0V Stator 0-0V 0-0V Guide disc Motor housing Bearing cover Fan Switch housing Switch housing for variable speed, includes potentiometer 0-0V 0-0V Switch cover Lock washer Lower housing Wave washer Ball bearing Screw Screw for 0-0V Screw for 0-0V Ground screw Gasket, 0-0V Gasket, 0-0V Earthing lead Lead Screw Ball bearing Motor coupling Power cord w/strain relief & plug 0-0V 0-0V Hexagon nut Rod connector Brush holder Carbon brush 0-0V 0-0V Star washer Overload switch,.5 amp 0-0V 5 amp 0-0V low voltage release EMI Filter Repair kit 0-0V (includes PN s & () 509) Repair kit 0-0V (includes PN s & () 0) LVR LVR LVR SP-ENC Series motor should not be used to pump flammables. 5

6 Standard Pump Operating Instructions and Parts Manual (OIPMI0) SP-A MOTOR SPARE PARTS ITEM * * 5 * 9* 0* DESCRIPTION Muffler Gasket Dead end cap Bearing ( required) Dead end plate Gasket ( required) Body Drive end plate Shaft seal Vane ( required) Dowel pin ( required) Impeller Repair kit* Includes item numbers,,, 9 and 0 A adapter PART SAF50 SAC9 SACA SAG59 SAC SAC5 SAE99 SAC SAC90A SAE9 SDA SAE9 SK5 900

7 Standard Pump Operating Instructions and Parts Manual SP-A SERIES MOTOR SPARE PARTS ITEM DESCRIPTION PART Housing assembly Inlet bushing (with Screen) 5 Trigger assembly Regulator assembly Muffler kit Rear-end plate assembly 9 Cylinder 0 Vanes (set of ) Rotor Front-end plate, assembly Motor lock-nut Motor coupling 5 Adaptor Trigger Lock (SP-AL only) A-A0 A-B A-A9 A-A9 A-AMK A-A A- A-- A-5 A-A A OP

8 Standard Pump Operating Instructions and Parts Manual (OIPMI0) DRUM PUMP SPECIFICATIONS Model Material Maximum Wetted Flow Discharge Of Construction Liquid Temperature Materials Rate Pressure SP-CPVC CPVC 90º F (90º C) CPVC, Carbon, Hastelloy C 5 gpm ( l/min) psi (, bar) SP-CPVC-HH CPVC 90º F (90º C) CPVC, Carbon, Hastelloy C gpm (0 l/min) psi (, bar) SP-PP Polypropylene 0º F (55º C) PP, Carbon, Hastelloy C 5 gpm ( l/min) psi (, bar) SP-PP-HH Polypropylene 0º F (55º C) PP, Carbon, Hastelloy C gpm (0 l/min) psi (, bar) SP-PHT Polypropylene 5º F (0º C) PP, Carbon, Hastelloy C 5 gpm ( l/min) psi (, bar) SP-PHT-HH Polypropylene 5º F (0º C) PP, Carbon, Hastelloy C gpm (0 l/min) psi (, bar) SP-PVDF PVDF (Kynar) 5º F (0º C) PVDF, Carbon, Hastelloy C 5 gpm ( l/min) psi (, bar) SP-PVDF-HH PVDF (Kynar) 5º F (0º C) PVDF, Carbon, Hastelloy C gpm (0 l/min) psi (, bar) SP-SS SS 5º F (0º C) SS, Carbon, Teflon 5 gpm ( l/min) psi (, bar) SP-SS-HH SS 5º F (0º C) SS, Carbon, Teflon gpm (0 l/min) psi (, bar) PUMP PACKAGE SPECIFICATIONS Electric Motor Pump Packages Model HP Voltage Phase Meter Wetted Immersion Hose Nozzle Components Length Length Material 900 0V No Polypropylene, Carbon, 9 (000 mm) ft. (, meters) Polypropylene Hastelloy C, PVC, Viton 90 0V No Polypropylene, Carbon, 9 (000 mm) ft. (, meters) Polypropylene Hastelloy C, PVC, Viton 90 0V No Polypropylene, Carbon, (00 mm) ft. (, meters) Polypropylene Hastelloy C, PVC, Viton 90 0V No Polypropylene, Carbon, (00 mm) ft. (, meters) Polypropylene Hastelloy C, PVC, Viton 90 0V No SS, Teflon, Carbon, 9 (000 mm) ft. (, meters) Aluminum Aluminum, PVC, Buna 9 0V No SS, Teflon, Carbon, 9 (000 mm) ft. (, meters) Aluminum Aluminum, PVC, Buna 9 0V No SS, Teflon, Carbon, (00 mm) ft. (, meters) Aluminum Aluminum, PVC, Buna 9 0V No SS, Teflon, Carbon, (00 mm) ft. (, meters) Aluminum Aluminum, PVC, Buna

9 Standard Pump Operating Instructions and Parts Manual Electric Motor Pump Packages (continued) Model HP Voltage Phase Meter Wetted Immersion Hose Nozzle Components Length Length Material 90 0V No PVDF, Carbon, Hastelloy C, Alphasyn, Viton 9 (000 mm) ft. (, meters) PVDF 9 0V No PVDF, Carbon, Hastelloy C, Alphasyn, Viton 9 (000 mm) ft. (, meters) PVDF 9 0V No PVDF, Carbon, Hastelloy C, Alphasyn, Viton (00 mm) ft. (, meters) PVDF 9 0V No PVDF, Carbon, Hastelloy C, Alphasyn, Viton (00 mm) ft. (, meters) PVDF 90 0V No CPVC, Polypropylene, Carbon, 9 (000 mm) ft. (, meters) Polypropylene Hastelloy C, PVC, Viton 9 0V No CPVC, Polypropylene, Carbon 9 (000 mm) ft. (, meters) Polypropylene Hastelloy C, PVC, Viton 9 0V No CPVC, Polypropylene, Carbon, (00 mm) ft. (, meters) Polypropylene Hastelloy C, PVC, Viton 9 0V No CPVC, Polypropylene, Carbon (00 mm) ft. (, meters) Polypropylene Hastelloy C, PVC, Viton V Yes Polypropylene, Carbon, Hastelloy C, PVC, 9 (000 mm) ft. (, meters) Polypropylene Viton, Ceramic, PVDF, Halar 950 0V Yes Polypropylene, Carbon, Hastelloy C, PVC, 9 (000 mm) ft. (, meters) Polypropylene Viton, Ceramic, PVDF, Halar 950 0V Yes Polypropylene, Carbon, Hastelloy C, PVC, (00 mm) ft. (, meters) Polypropylene Viton, Ceramic, PVDF, Halar 950 0V Yes Polypropylene, Carbon, Hastelloy C, PVC, (00 mm) ft. (, meters) Polypropylene Viton, Ceramic, PVDF, Halar 950 0V Yes PVDF, Carbon, Hastelloy C, Alphasyn 9 (000 mm) ft. (, meters) PVDF Viton, Ceramic, Halar 95 0V Yes PVDF, Carbon, Hastelloy C, Alphasyn 9 (000 mm) ft. (, meters) PVDF Viton, Ceramic, Halar 95 0V Yes PVDF, Carbon, Hastelloy C, Alphasyn (00 mm) ft. (, meters) PVDF Viton, Ceramic, Halar 95 0V Yes PVDF, Carbon, Hastelloy C, Alphasyn (00 mm) ft. (, meters) PVDF Viton, Ceramic, Halar Air Motor Pump Packages Model HP Air Meter Wetted Immersion Hose Nozzle Consumption Components Length Length Material CFM (0. No SS, Teflon, Carbon, 9 (000 mm) ft. (, meters) Aluminum 90 psi (, bar) Aluminum, Buna, UHMWPE CFM (0. No SS, Teflon, Carbon, (00 mm) ft. (, meters) Aluminum 90 psi (, bar) Aluminum, Buna, UHMWPE CFM (. No SS, Teflon, Carbon, 9 (000 mm) ft. (, meters) Aluminum 90 psi (, bar) Aluminum, Buna, UHMWPE CFM (. No SS, Teflon, Carbon, (00 mm) ft. (, meters) Aluminum 90 psi (, bar) Aluminum, Buna, UHMWPE 9

10 Standard Pump Operating Instructions and Parts Manual (OIPMI0) Assembly. Remove the pump and motor from packaging.. Inspect all contents for damage.. Couple the motor to the pump tube by using the Hand Wheel. (See figure ).. Remove the pump foot. (see Figure ) Figure When using an SP-A or SP-A Series motor, Standard Pump recommends the use of a Filter Lubricator Regulator (FLR) in order to ensure a moisture free supply of air to the motor. SP-A and SP-A Series motors must be lubricated daily to ensure proper functionality. Operation. Once the pump is fully assembled and all connections are securely fastened, insert the pump into the drum or tank.. Turn the motor switch to the ON position or open air inlet valve.. If your package contains a flow meter (Package numbers or ) please reference the factory operating instructions which are located in your carton.. After use, clean the pump and store vertically. Figure Pump Foot NOTE: Remove pump foot by turning clockwise.. While holding the drive shaft with pliers (factory suggests using grip-locks to avoid scarring shaft) remove the impeller by turning counter clockwise (see Figure ). Maintenance Disassembly / Cleaning Procedures. In order to clean a majority of the residue from the pump tube, immerse the pump into a 55 Gallon Drum of water. Allow the pump to circulate the water for minutes.. For a more thorough cleaning remove the motor from the pump tube by loosening the hand wheel (see Figure ). Figure NOTE: Use grip lock pliers to hold shaft while removing impeller. Figure 0

11 Standard Pump Operating Instructions and Parts Manual 5. Remove the Pump Housing (see Figure 5). Figure Figure 5. Remove pump coupling (P/N: 00) from drive shaft by turning counterclockwise (see Figure ). NOTE: Use grip-lock pliers to hold shaft while removing coupling. NOTE: Remove pump housing by turning clockwise.. For plastic models remove outer tube and inner tube from discharge housing by turning clockwise (see Figure ). Inner Tube Inner Tube Figure Outer Tube. For stainless steel models (i.e. SP-SS Series, 90-9 & ), remove connection flange (P/N 0) from inner/ outer tube assembly by turning clockwise (see Figure ). Figure Figure 9 9. Pull drive shaft straight down removing it from the discharge housing or connection flange while inserting a screwdriver through bearing unit (P/N: 0) (see Figure 9). NOTE: Ensure screwdriver is maintained inside bearing unit so spacer and seal are stationary and aligned properly for reassembly. When replacing the drive shaft in the bearing unit (P/N0) during reassembly, make sure the drive shaft is inserted through the spacer in between the bearings inside the bearing unit. Failure to do so could cause the bearing unit to prematurely fail.

12 Standard Pump Operating Instructions and Parts Manual (OIPMI0) POLYPROPYLENE PUMP SERIES ITEM DESCRIPTION PART * 5* 9 0* * * 5 V-seal, Viton Pump Coupling Drive Shaft, Hastelloy " (00 mm) 9" (000 mm) " (00 mm) 50" (0 mm) 0" (500 mm) " (00 mm) Discharge Housing Bearing Unit Assembled each Viton shielded bearings, spacer, snap ring, bearing can Hose Barb,.5" (9 mm) " (5 mm) Wing Nut Snap Ring Guide Sleeve, PTFE " (00 mm) 9" (000 mm), " (00 mm), 50" (0 mm) 0" (500 mm), " (00 mm) Pump Housing (Includes Carbon Bushing) Inner Tube, " (00 mm) 9" (000 mm) " (00 mm) 50" (0 mm) 0" (500 mm) " (00 mm) Outer Tube, " (00 mm) 9" (000 mm) " (00 mm) 50" (0 mm) 0" (500 mm) " (00 mm) High Volume Impeller High Pressure Impeller High Volume Pump Foot High Pressure Pump Foot Hand Wheel Repair Kit (*Includes Items, 5, 0,, & ) HH HH 9050 Polypropylene pumps should not be used to pump flammables.

13 Standard Pump Operating Instructions and Parts Manual CPVC PUMP SERIES ITEM DESCRIPTION PART * 5* 9 0* * * 5 V-Seal, PTFE Pump Coupling Drive Shaft, Hastelloy " (00 mm) 9" (000 mm) " (00 mm) 50" (0 mm) 0" (500 mm) " (00 mm) Discharge Housing Bearing Unit Assembled each Viton shielded bearings, spacer, snap ring, bearing can Hose Barb,.5" (9 mm) " (5 mm) Wing Nut Snap Ring Guide Sleeve, PTFE " (00 mm) 9" (000 mm), " (00 mm), 50" (0 mm) 0" (500 mm), " (00 mm) Pump Housing (Includes Carbon Bushing) Inner Tube, " (00 mm) 9" (000 mm) " (00 mm) 50" (0 mm) 0" (500 mm) " (00 mm) Outer Tube, " (00 mm) 9" (000 mm) " (00 mm) 50" (0 mm) 0" (500 mm) " (00 mm) High Volume Impeller High Pressure Impeller High Volume Pump Foot High Pressure Pump Foot Hand Wheel Repair Kit (*Includes Items, 5, 0,, & ) HH HH 905 CPVC pumps should not be used to pump flammables.

14 Standard Pump Operating Instructions and Parts Manual (OIPMI0) STAINLESS STEEL PUMP SERIES ITEM DESCRIPTION PART * * 5 9* 0 * * 5 Pump Coupling Bearing Unit Assembled each Viton shielded bearings, spacer, snap ring, bearing can Snap Ring Hand Wheel Connection Flange, SS Drive Shaft, SS " (00 mm) 9" (000 mm) " (00 mm) 0" (500 mm) " (00 mm) Guide Sleeve, PTFE " (00 mm) 9" (000 mm) / " (00 mm) 0" (500 mm) " (00 mm) Wing Nut, SS Seal, PTFE Hose Barb, SS.5" (9 mm) " (5 mm) Inner/Outer Tube Assembly, SS " (00 mm) 9" (000 mm) " (00 mm) 0" (500 mm) " (00 mm) Pump Housing with Carbon Bushing, SS High Volume Impeller, PTFE High Pressure Impeller, PTFE O-Ring, Viton ( per set) High Volume Pump Foot, SS High Pressure Pump Foot, SS V-Seal, PTFE Repair Kit (*Includes Items,, 9, & ) HH HH When pumping flammables or combustible liquids, this pump must be used in conjunction with an explosion proof motor.

15 Standard Pump Operating Instructions and Parts Manual PVDF PUMP SERIES ITEM DESCRIPTION PART * * * * 5* Pump Coupling Drive Shaft, Hastelloy " (00 mm) 9" (000 mm) " (00 mm) 50" (0 mm) 0" (500 mm) " (00 mm) Bearing Unit Assembled each Viton shielded bearings, spacer, snap ring, bearing can Snap Ring Guide Sleeve, PTFE " (00 mm) 9" (000 mm), " (00 mm), 50" (0 mm) 0" (500 mm), " (00 mm) Hand Wheel V-Seal, PTFE Discharge Housing Hose Barb,.5" (9 mm) " (5 mm) Wing Nut Inner Tube, " (00 mm) 9" (000 mm) " (00 mm) 50" (0 mm) 0" (500 mm) " (00 mm) Outer Tube, " (00 mm) 9" (000 mm) " (00 mm) 50" (0 mm) 0" (500 mm) " (00 mm) Pump Housing (Includes Carbon Bushing) High Volume Impeller High Pressure Impeller High Volume Pump Foot High Pressure Pump Foot Repair Kit (*Includes Items,,, & 5) HH 09 09HH 905 PVDF pumps should not be used to pump flammables. 5

16 Standard Pump Operating Instructions and Parts Manual (OIPMI0) HIGH TEMPERATURE POLYPROPYLENE PUMP SERIES ITEM DESCRIPTION PART * 5* 9 0* * * 5 V-Seal, PTFE Pump Coupling Drive Shaft, Hastelloy " (00 mm) 9" (000 mm) " (00 mm) 50" (0 mm) 0" (500 mm) " (00 mm) Discharge Housing Bearing Unit Assembled ( each) Viton shielded bearings, spacer, snap ring, bearing can Hose Barb,.5" (9 mm) " (5 mm) Wing Nut Snap Ring Guide Sleeve, PTFE " (00 mm) 9" (000 mm), " (00 mm), 50" (0 mm) 0" (500 mm), " (00 mm) Pump Housing (Includes Carbon Bushing) Inner Tube, " (00 mm) 9" (000 mm) " (00 mm) 50" (0 mm) 0" (500 mm) " (00 mm) Outer Tube, " (00 mm) 9" (000 mm) " (00 mm) 50" (0 mm) 0" (500 mm) " (00 mm) High Volume Impeller High Pressure Impeller High Volume Pump Foot High Pressure Pump Foot Hand Wheel O-Ring, Viton Repair Kit (*includes items, 5, 0,, & ) HH HH High Temperature Polypropylene pumps should not be used to pump flammables.

17 Standard Pump Operating Instructions and Parts Manual Progressive Cavity SP-00SR, SP-00DD MOTOR SPECIFICATIONS SP-00SR Series Motors SP-ENC Series see page. SP-00DD Series Motors Model Voltage Amps Watts HP Phase Hz Enclosure Variable Explosion Air Consumption Airline Size Speed Proof Inches (mm) SP-50 90/0-0/0V -. 0,5 KW TEFC (IP5) N N N/A N/A SP-5 90/0-0/0V.-. 0,5 KW 50-0 TEFC (IP5) N N N/A N/A SP-5 90/0-0/0V.9-., KW TEFC (IP5) N N N/A N/A SP-A N/A N/A,5 KW N/A N/A N/A Y Y 0 CFM ( L/sec) ) PSI ( Bar or greater SP-A N/A N/A,0 KW N/A N/A N/A Y Y 0 CFM (5 L/sec) PSI ( Bar) or greater SP-A N/A N/A, KW 5 N/A N/A N/A Y Y 0 CFM (0 L/sec) PSI ( Bar) or greater

18 Standard Pump Operating Instructions and Parts Manual (OIPMI0) SP-A SERIES SPARE PARTS A Body styles may differ, depending on specific models. ITEM DESCRIPTION QUANTITY PART Service kit only service kits are available for parts replacement * Denotes parts included in the Service Kit K0C * * A* 5* * * 9* 0 * * Shaft Seal Bearing, Drive End Bearing, Dead End End Plate, Drive Rotor Assembly Vane Push Pin Vane, Spring Body Shims End Plate, Dead End Cap, Gasket End Cap, Dead Muffler Assembly Muffler Felt B AB59 AA99J AK5A AM55C AM0M B0 ABM AA AM0D AC90 AC9

19 Standard Pump Operating Instructions and Parts Manual SP-A SERIES SPARE PARTS ITEM DESCRIPTION QUANTITY PART Service kit only service kits are available for parts replacement * Denotes parts included in the Service Kit KA * * * 5 * 9 0 * * * 5* * * End Cap, Drive End Shaft Seal O-Ring Bearing, Drive End Dowel Pin End Plate, Drive Body Gasket Body Key Rotor Assembly Push Pin Vane, Spring Vane End Plate, Dead Bearing, Dead End End Cap, Gasket End Cap, Dead End Muffler Assembly Felt AC99 AK AC99 AC9B ABC AK AD AD5D AK ADE AD55A AD9 AD9 AD5 AB59 AD AD AC990 AC99 9

20 Standard Pump Operating Instructions and Parts Manual (OIPMI0) SP-A SERIES SPARE PARTS ITEM DESCRIPTION QUANTITY PART Service kit only service kits are available for parts replacement * Denotes parts included in the Service Kit KA * * * 5 * 9 0 * * * 5* * * End Cap, Drive End Shaft Seal O-Ring Bearing, Drive End Dowel Pin End Plate, Drive Body Gasket Body Key Rotor Assembly Push Pin Vane, Spring Vane End Plate, Dead Bearing, Dead End End Cap, Gasket End Cap, Dead End Muffler Assembly Felt AC9 AK0 AC99 AB9 AB AK AC ACG AK AC9D AC9 AC AC AC9 AC9B AC AC AC990 AC99 0

21 Standard Pump Operating Instructions and Parts Manual SP-00SR SERIES Specifications Models SP-00SR Maximum Liquid Temperature...Teflon & Viton Stator 00º F (º C) Buna Stator 5º F (5º C) Pump Type... Progressive Cavity (Positive Displacement) Pump Speed RPM Max. Flow Rate...5 & 5... GPM ( LPM) 5... GPM (5 LPM) Max. Discharge Pressure...5 & 5... psi ( bar) 5... psi ( bar) Immersion Length..." (00 mm), 9" (000 mm) (Drums) & " (00 mm) (Tanks) Wetted Materials...SS, Teflon, Buna or Viton Discharge Port....5" ( mm) Hose Barb (Optional.5" ( mm) Hose Barb) Max. Viscosity...5 & ,000 cps (mpas) ,000 cps (mpas) Max. Solid Size....5" ( mm) Motor... SP-ENC Series Notes. Pump stator elastomer (Teflon & Buna) may vary performance.. Performance is based on using a 900 RPM motor. Reducing motor speed will decrease pump performance.. The SP-00SR Series pump is equipped with a gear reduction unit which reduces the speed of the pump to between 50 and 900 RPM s. The motor speed must not exceed,000 RPM s in order to achieve the proper operating RPM s of the pump.. Performance will vary depending on whether the product being pumped is newtonian (viscosity remains constant regardless of shear) or non-newtonian (viscosity does not remain constant with shearing). 5. Flow rates are based on water. As viscosity increases, the flow rate will decrease. The SP-00SR Series Pump is recommended for intermittent duty use only. (ie., 0 minute intervals with a 0 minute cooling off period). For continuous duty applications, Standard Pump recommends using the SP-00DD Series Pump. The SP-00SR Series Pump is positive displacement pumps and should never be operated against shut-off elements such as nozzles, valves, etc. Failure to comply may result in excessive pressure build resulting in serious injury and pump damage. The SP-00SR Series Pump should not run dry. Running the pump dry will result in damage to the mechanical seal and stator of the pump. Assembly. Remove the pump and motor from packaging.. Inspect all contents for damages.. Couple the electric motor to the pump using the hex nut (see Figure ).. First pump clean water in order to familiarize yourself with the pump s operation, flow rate, discharge pressure and motor speed. Figure Attach Motor by Turning Hex Nut Clockwise Operation. Once the pump is fully assembled and all connections are fastened, insert the pump into the drum or tank (see Figure ). Figure. It is recommended to attach a suitable hose or pipe to the pump discharge. Make sure the hose meets the pump discharge pressure requirements (SP-00-5 or SP-00-5= psi ( bar)) / (SP-00-5= psi (, bar). It is recommended to use a hose that is rated x the pump discharge pressure. Ex: x = psi (, bar).. If you opt to use a hose, fasten the hose to the hose barb with a suitable hose clamp that exceeds the pump discharge pressure.. Make sure the speed control knob on the motor is turned to the MIN position (completely counterclockwise). 5. Turn the motor switch to the ON position.. Slowly throttle the motor up by turning the speed control knob clockwise. Do not use these pumps for the transfer of flammable or combustible products or in an environment where flammable or combustible fumes are present. Maintenance & Disassembly (See page )

22 Standard Pump Operating Instructions and Parts Manual (OIPMI0) SP-00DD SERIES Specifications Models SP-00DD Maximum Liquid Temperature...Teflon & Viton Stator 00º F (º C) Buna Stator 5º F (5º C) Pump Type... Progressive Cavity (Positive Displacement) Pump Speed RPM Max. Flow Rate...5 & 5... GPM ( LPM) 5... GPM (5 LPM) Max. Discharge Pressure...5 & 5... psi ( bar) 5... psi ( bar) Immersion Length..." (00 mm), 9" (000 mm) (Tanks) & " (00 mm) (Drums) Wetted Materials...SS, Teflon, Buna or Viton Discharge Port....5" ( mm) Hose Barb Tri-Clamp (Optional.5" ( mm) Hose Barb) Max. Viscosity...5 & ,000 cps (mpas) ,000 cps (mpas) Max. Solid Size....5" ( mm) Motors...SP-500 Series, SP-A, SP-A, SPA Notes. Pump stator elastomer (Teflon & Buna) may vary performance.. Performance is based on using a 900 RPM motor. Reducing motor speed will decrease pump performance. Do not increase motor speed above 900 RPM. Failure to comply will result in premature pump failure.. Performance will vary depending on whether the product being pumped is newtonian (viscosity remains constant regardless of shear) or non-newtonian (viscosity does not remain constant with shearing).. Flow rates are based on water. As viscosity increases, the flow rate will decrease. The SP-00DD Series Pump is positive displacement pumps and should never be operated against shut-off elements such as nozzles, valves, etc. Failure to comply may result in excessive pressure build resulting in serious injury and pump damage. The SP-00DD Series Pump should not run dry. Running the pump dry will result in damage to the mechanical seal and stator of the pump. Assembly. Remove the pump and motor from packaging.. Inspect all contents for damages.. Couple the motor to the pump. Bolt electric or pneumatic motor to the pump using the hardware provided by the manufacturer (see figure ).. Motor a) Electric make sure motor and plug are wired to proper voltage and clockwise direction. Use wiring diagram on nameplate. b) Air for optimum performance make sure proper size airlines are installed. When using an SP-A, SP-A or SP-A motor, Standard Pump recommends the use of a Fliter Lubricator Regulator (FLR) in order to ensure a moisture free supply of air to the motor. SP-A, SP-A and SP-A motors must be lubricated daily to ensure proper functionality. Model Air Connection Consumption SP-A.5" (, mm) 0 00 psi bar SP-A.5" (, mm) 0 00 psi 5 bar SP-A.5" (, mm) 0 00 psi 0 bar Do not operate the SP-00DD-5 series pump on viscosities greater than 0,000 cps (mpas). Do not operate the SP-00DD-5 or SP-00DD-5 series pumps on viscosities greater than 00,000 cps (mpas). Failure to comply will result in premature pump failure. When using an SP-00DD pump in conjunction with an air motor (SP-A, SP-A or SP-A), make sure the air line is connected to the air inlet hole on the left side of the motor as you face the motor. This will insure that the motor turns in a clockwise direction. Use the pump arrow to verify proper direction. If the pump rotates counterclockwise, the internal components will disassemble. Do not use these pumps for the transfer of flammable or combustible products or in an environment where flammable or combustible fumes are present unless used in conjunction with Explosion Proof or Air motor as well as proper grounding and bonding wires. Please consult the factory or authorized distributor with any questions regarding installation (see page ). Operation. Once the pump is fully assembled and all connections are fastened, insert the pump into the drum or tank. Pump can be suspended from hoisting system using a pump hanger (P/N: ). P/N: Figure

23 Standard Pump Operating Instructions and Parts Manual. It is recommended to attach a suitable hose or pipe to the pump discharge.. If you opt to use a hose, fasten the hose to the hose barb with a suitable hose clamp that exceeds the pump discharge pressure. Make sure the hose meets the pump discharge pressure requirements (SP-00-5 or SP-00-5= psi ( bar)) / (SP-00-5= psi (, bar)). It is recommended to use a hose that is rated x the pump discharge pressure. Ex: x = psi (, bar). Maintenance DISASSEMBLY / CLEANING PROCEDURES (SP-00SR & SP-00DD). Remove motor from pump tube. For models SP-00SR: loosen Hex Nut in clockwise rotation (see Figure ).. Loosen set screw on side of Hex Nut (see Figure 5).. Place a screwdriver (or similarly shaped object) in the mechanical seal inspection port (see Figure 5).. Use a large wrench to loosen the Hex Nut while simultaneously holding the screwdriver in the seal inspection port (see Figure 5). Mechanical Seal Inspection Port Hex Nut Set Screw Figure 5 NOTE: Turn hex nut clockwise to loosen Figure 5. Once the Hex Nut is loosened, remove the outer tube from the drive shaft assembly (see Figure ). NOTE: Remove motor by turning hex nut clockwise For models SP-00DD: loosen () bolts that attach the pump to the motor (see Figure ). Drive Shaft Assembly Figure Outer Tube Assembly NOTE: Remove bolts from motor flange. NOTE: Steps -9 of DISASSEMBLY / CLEANING procedures as well as mechanical seal replacement and pump assembly are the same for the SP-00SR and SP-00DD series pump tubes. Figure

24 Standard Pump Operating Instructions and Parts Manual (OIPMI0). Remove the stator from the pump tube body by turning clockwise (see Figure ). Outer Tube Assembly MECHANICAL SEAL REPLACEMENT/ PUMP ASSEMBLY (SP-00SR & SP-00DD). Follow steps -9 under the Disassembly / Cleaning Procedures from above.. The mechanical seal will be exposed in the lower portion of the mechanical seal bushing (see Figure 0). Mechanical Seal Mechanical Seal Bushing O-Ring Seal Stator Seal O-Ring Washer Figure. Hold the drive shaft in a fixed position and loosen the rotor (counterclockwise) located at the bottom of the drive shaft (see Figure ). Drive Shaft Assembly Rotor Figure. Insert a small screwdriver (or similar object) through the small hole on the shaft located inside the mechanical seal inspection port (see Figure 9). 9. While holding the small shaft still, loosen (counterclockwise) the pump drive shaft with large wrench. (see Figure 9). Figure 0 Spring. Remove damaged seal and replace with a new mechanical seal. Use a suitable lubricant on the seals O-rings. Wear gloves when performing seal maintenance. Touching the seal face could cause premature failure.. Reinstall mechanical seal bushing into bearing housing. 5. Thread drive shaft onto bearing housing shaft (see Figure 9).. Thread rotor onto drive shaft (see Figure ).. Thread stator can onto pump body (see Figure ).. Apply a suitable lubricant on rotor. 9. Once Bearing Housing, drive shaft, and rotor are securely threaded together, insert this assembly into the pump body (see Figure, page ). 0. Tighten the Hex Nut on the pump body to the Bearing housing. Use screwdriver (or similarly shaped object) in the mechanical seal inspection port (see Figure 5, page ).. Use a large wrench to tighten the Hex Nut while simultaneously holding the screwdriver in the seal inspection port (see Figure 5, page ).. Replace set screw into hex nut.. Reattach motor and resume operation. (SP-00SR: see Figure, page ); (SP-00DD: see Figure, page ). TFE Series Only Notch On TFE Stator Stainless Steel O-Ring Seats into Top of Stator Tube Stator Tube Top View Stator Tube with TFE Stator Inserted Inside Drive Shaft Assembly Pin On Inside Stator Tube Figure 9 Note: Slide the TFE stator into the stator tube. Make sure the pin on the stator tube lines up with the notch on the TFE stator insert.

25 Standard Pump Operating Instructions and Parts Manual SP-00SR SERIES SPARE PARTS ITEM DESCRIPTION PART 5 Pump Coupling 00 Connection Nut, SS Snap Ring, SS 0 Gear Reduction Unit, SS & Aluminum 0 5 Mechanical Seal Bushing, SS 0 Mechanical Seal, SIC 0 Gasket, PTFE 5 Drive Shaft, SS Pump Sizes - SP-5-, SP-5-, SP-5-0 Pump Sizes - SP Pump Sizes - SP-5-9, SP-5-9, SP-5-0 Pump Sizes - SP-5-, SP Rotor, SS Size 5 0 Size 5 09 Size Gasket, PTFE Outer Tube Assembly, SS Pump Sizes - SP-5-, SP-5-, SP-5-0 Pump Sizes - SP-5-9 Pump Sizes - SP-5-9, SP-5-9, SP-5- Pump Sizes - SP-5-, SP Stator Buna* (SS Tube) Size 5 Size 5 Size 5 5 Viton* (SS Tube) Size 5 9 Size 5 0 Size 5 PTFE (Stator Insert Only) Size 5 Size 5 Size 5 Stator Tube,** SS Size 5 Size 5 5 Size 5 Wing Nut, SS 5 Hose Barb, SS.5" ( mm).5" ( mm) 9 O-Ring, PTFE 0 Viton 0V Buna 0B Gasket, Buna PTFE Viton 9 Set Screw, SS 5 9 Ring, SS (For Use with Teflon Stator Only) 00 *Includes Stator & Stator Tube. ** Does not include Stator # (PTFE stator only). 5

26 Standard Pump Operating Instructions and Parts Manual (OIPMI0) SP-00DD SERIES SPARE PARTS ITEM DESCRIPTION PART Motor Coupling SP-500 & SP-A Models mm 0 SP- model - mm SP-A model - 9 mm SP-50 & SP-50 Models mm Coupling Insert 5 Motor Mount Flange, Aluminum Bearing Housing Assembly, Aluminum 59 5 Mechanical Seal Bushing, SS 0 Mechanical Seal, SIC 0 Gasket, PTFE 5 Drive Shaft, SS Pump Sizes - SP-5-, SP-5-, SP-5-0 Pump Sizes - SP Pump Sizes - SP-5-9, SP-5-9, SP-5-0 Pump Sizes - SP-5-, SP Rotor, SS Size 5 0 Size 5 09 Size Outer Tube Assembly, SS Pump Sizes - SP-5-, SP-5-, SP-5-0 Pump Sizes - SP-5-9 Pump Sizes - SP-5-9, SP-5-9, SP-5- Pump Sizes - SP-5-, SP-5- Stator Buna* (SS Tube) Size 5 Size 5 Size 5 5 Viton* (SS Tube) Size 5 9 Size 5 0 Size 5 PTFE (Stator Insert Only) Size 5 Size 5 Size 5 Stator Tube,** SS Size 5 Size 5 5 Size 5 Wing Nut, SS Hose Barb, SS.5" ( mm).50" ( mm) 9 5 O-Ring, PTFE 0 Buna 0B Viton 0V Gasket, PTFE Gasket, Buna PTFE Viton 9 Set Screw, SS 5 9 Ring, SS (For Use with Teflon Stator Only) 00 *Includes Stator & Stator Tube. ** Does not include Stator # (PTFE stator only).

27 Standard Pump Operating Instructions and Parts Manual Use Of Air Motors In Hazardous Atmospheres At the present time, there are no known standards governing the operation of air motors in hazardous atmospheres. However, there are several points regarding the safety of air motors. First of all, an air motor is not a source of electric sparks. However, it is possible that an article which is not part of the air motor (e.g., wrenches, hammers, etc.) could create a spark by sharply impacting a cast iron or aluminum case or the steel shaft of the air motor. (Note that electric motor enclosures for both class I and II hazardous locations can be made of...iron, steel, copper, bronze, or aluminum... (UL, Electric Motors and Generators Hazardous Locations, June, 99; paragraph., page ). Second, an air motor housing is not designed to contain an internal explosion as is an explosion-proof electric motor. The only possible internal source of ignition in an air motor is a contact between the station housing components and the rotating elements that might create a spark. The likelihood of this occurring is reduced by the fact that the contact must be made at precisely the same time as a flammable or explosive gas is introduced into the air motor in a sufficient quantity to achieve a flammable or explosive mixture while overcoming the positive pressure of the driving gas. In other words, although highly improbable, an internal explosion in an air motor is possible. Finally, an air motor is designed to be operated by compressed air, the expansion of which in normal operation creates a cooling effect. As a result, the temperature of the air motor will not exceed the height of the temperatures of the surrounding atmosphere or the air delivered to the inlet. We do not guarantee the safety of every application, but to ensure the safe operation of an air motor in your application, always follow the product direction and consult with a qualified engineer. (Source: Gast Manufacturing, Air Motors Handbook, page ) Note: This statement is only applicable in North America. Grounding Procedures TRANSFERRING OF FLAMMABLES OR USE IN HAZARDOUS DUTY Bonding is an electrical connection between a primary metal vessel and a metal receiving vessel. See schematic. Grounding is an electrical connection between a metal vessel, pump, motor and a constant ground; i.e. a metal rod driven into the earth. Bonding and grounding are required when pumping flammable materials or in hazardous duty environments. Failure to bond and ground properly can cause a discharge of static electricity resulting in fire, injury or death. Follow NFPA and 0 procedures at all times. If in doubt, do not start pump! Be sure bonding and grounding wires are secure before starting operation. (Ground and bond wires must have less than one ohm resistance for safe usage. Check continuity before starting). Always check with a safety engineer when any question arises and periodically check safety procedures with a safety engineer Air Line Exhaust Line Ground Wire Solvent resistant safety hose with wire ground Bond Wire Metal Drum Rod Earth Ground

28 WARRANTY Declarations Declaration of Conformity Declaration of Incorporation When this unit is used as a stand alone unit it complies with: Machinery Directive 9//EC EN00, EN05--, EN05-, Low Voltage Directive //Eec EN00-, EMC Directive 9//Eec EN550, EN 5500, EN500-, EN500- When this pump unit is to be installed into machine or is to be assembled with other machines for installations, it must not be put into service until the relevant machinery has been declared in conformity with Machine Directive 9//EC EN00, EN05--, EN05-. Three year limited warranty Responsible person: Donald M. Murphy, President, Standard Pump, Inc. 50 University Drive, Auburn, Georgia 00 Ph: Fax: info@standardpump.com Standard Pump, Inc. warrants, subject to the conditions below, through either Standard Pump, Inc., it s subsidiaries, or its authorized distributors, to repair or replace free of charge, including labor, any part of this equipment which fails within three years of delivery of the product to the end user. Such failure must have occurred because of defect in material or workmanship and not as a result of operation of the equipment other than in accordance with the instructions given in this material. Specific exceptions include: Consumable items such as motor brushes, bearings, couplings and impellers. (Motor brushes typically have a life span of approximately 00 hours. This will vary with the manner in which the motor is used) Conditions of exceptions include: Equipment must be returned by prepaid carriage to Standard Pump, Inc., its subsidiary or authorized distributor. All repairs, modifications must have been made by or with express written permission by Standard Pump, Inc., it s subsidiary or authorized distributor. Equipment which have been abused, misused, or subject to malicious or accidental damage or electrical surge are excluded. Warranties purporting to be on behalf of Standard Pump, Inc. made by any person, including representatives of Standard Pump, Inc, its subsidiaries, or its distributors, which do not fall within the terms of this warranty shall not be binding upon Standard Pump, Inc. unless expressly approved in writing by a Director or Manager of Standard Pump, Inc. Information for returning pumps Equipment which has been contaminated with, or exposed to, bodily fluids, toxic chemicals or any other substance hazardous to health must be decontaminated before it is returned to Standard Pump, Inc, or its distributor. A returned goods authorization number (RGA #) issued by Standard Pump, Inc., its subsidiary or authorized distributor, must be included with the returned equipment. The RGA # is required if the equipment has been used. If the equipment has been used, the fluids that have been in contact with the pump and the cleaning procedure must be specified along with a statement that the equipment has been decontaminated. STANDARD PUMP 50 University Drive, Auburn, Georgia 00 USA TOLL FREE Phone Fax info@standardpump.com

Operating Instructions and Parts Manual Industrial Pump Models: SP-PP, SP-PHT, SP-CPVC, SP-PVDF, SP-SS, & SP-700SR & SP-700DD

Operating Instructions and Parts Manual Industrial Pump Models: SP-PP, SP-PHT, SP-CPVC, SP-PVDF, SP-SS, & SP-700SR & SP-700DD Operating Instructions and Parts Manual Industrial Pump Models: SP-PP, SP-PHT, SP-CPVC, SP-PVDF, SP-SS, & SP-00SR & SP-00DD TABLE OF CONTENTS PAGE STANDARD PUMP 0 University Dr., Auburn, Georgia 00 USA

More information

Centrifugal Drum Pump Motor Models: SP-410EX, SP-420EX, SP-280P, SP-ENC, SP-A1 & SP-A2

Centrifugal Drum Pump Motor Models: SP-410EX, SP-420EX, SP-280P, SP-ENC, SP-A1 & SP-A2 Standard Pump Standard s Drum Pumps are designed to transfer a variety of materials from 55 gallon drums and tanks. Standard Pump offers several different pumps, each designed for specific applications.

More information

Models: 8500, 8501, 8513, 8514, 8500BL, 8501BL, 8513BL, 8514BL, 8540, 8541, 8550, 8551, 8540BL, 8541BL, 8550BL & 8551BL

Models: 8500, 8501, 8513, 8514, 8500BL, 8501BL, 8513BL, 8514BL, 8540, 8541, 8550, 8551, 8540BL, 8541BL, 8550BL & 8551BL Standard Pump Ultra Mass High Viscosity Batch Control System Description Standard s Drum Pumps are designed to transfer a variety of materials from 55 gallon drums and tanks. Standard Pump offers several

More information

POLYPROPYLENE PUMP TUBE SP-PP SERIES

POLYPROPYLENE PUMP TUBE SP-PP SERIES POLYPROPYLENE PUMP TUBE SP-PP SERIES * * * 0 * V-seal - Viton Pump coupling Drive shaft, " (00 mm) Discharge housing Bearing unit assembled - each Viton shielded bearings, spacer, snap ring, bearing can

More information

1. Before operating the pump, read and understand these operating instructions.

1. Before operating the pump, read and understand these operating instructions. Standard Pump Description Standard s Drum Pumps are designed to transfer a variety of materials from 55 gallon drums and tanks. Standard Pump offers several different pumps, each designed for specific

More information

Models: 8500, 8501, 8513, 8514, 8500BL, 8501BL, 8513BL, 8514BL, 8540, 8541, 8550, 8551, 8540BL, 8541BL, 8550BL & 8551BL

Models: 8500, 8501, 8513, 8514, 8500BL, 8501BL, 8513BL, 8514BL, 8540, 8541, 8550, 8551, 8540BL, 8541BL, 8550BL & 8551BL Standard Pump Ultra Mass High Viscosity Batch Control System Description Standard s Drum Pumps are designed to transfer a variety of materials from 55 gallon drums and tanks. Standard Pump offers several

More information

Operating Instructions and Parts Manual

Operating Instructions and Parts Manual Operating Instructions and Parts Manual Industrial Pump Models: SP-PP, SP-PHT, SP-CPVC, SP-PVDF, SP-SS, SP-AL & SP-6600/6700 Series Pump Package Models: 9400, 9410, 9420, 9430, 9460, 9500, 9510, 9600 &

More information

4. All Federal, State, and local safety codes should be followed.

4. All Federal, State, and local safety codes should be followed. Standard Pump Description Standard s Drum Pumps are designed to transfer a variety of materials from 55 gallon drums and tanks. Standard Pump offers several different pumps, each designed for specific

More information

Operating Instructions and Parts Manual

Operating Instructions and Parts Manual Operating Instructions and Parts Manual Industrial Pump Models: SP-PP, SP-PHT, SP-CPVC, SP-PVDF, SP-7600/7700 & SP-6600/6700 Series Pump Package Models: 9400, 9420, 9430, 9500, 950, 970, 9760, 9900 & 990

More information

4. All Federal, State, and local safety codes should be followed.

4. All Federal, State, and local safety codes should be followed. Standard Pump 02 Description Standard s Drum Pumps are designed to transfer a variety of materials from 55 gallon (200 l) drums and tanks. Standard Pump offers several different pumps, each designed for

More information

O-0196 HIGH VISCOSITY DRUM & CONTAINER PUMPS

O-0196 HIGH VISCOSITY DRUM & CONTAINER PUMPS O-0196 HIGH VISCOSITY DRUM & CONTAINER PUMPS PAGE 2 SAFETY INFORMATION: BEFORE OPERATING THIS EQUIPMENT, THE OPERATOR SHOULD THOROUGHLY READ AND UNDERSTAND ALL INSTRUCTIONS AND SAFETY WARNING LABELS INCLUDING

More information

Drum & Container Pumps Installation and Operation Manual. TP-132/150 TP-160 TP-180 TP-280 TP-360 TP-380 TP-400Ex TP-AIR 1 TP-AIR 2 TP-AIR 3 S40675

Drum & Container Pumps Installation and Operation Manual. TP-132/150 TP-160 TP-180 TP-280 TP-360 TP-380 TP-400Ex TP-AIR 1 TP-AIR 2 TP-AIR 3 S40675 Drum & Container Pumps Installation and Operation Manual TP-3/50 TP-60 TP-80 TP-80 TP-360 TP-380 TP-00Ex TP-AIR TP-AIR TP-AIR 3 S0675 Index ITEM.............................................................................

More information

EF SERIES MOTORS OPERATION & PARTS MANUAL

EF SERIES MOTORS OPERATION & PARTS MANUAL EF SERIES MOTORS OPERATION & PARTS MANUAL Models S1, S2, S3, S4 S1, S2, S3 S4 EU Declaration of Conformity Finish Thompson Inc. hereby declares that the following motors fully comply with the applicable

More information

EF SERIES PUMPS OPERATION & PARTS MANUAL

EF SERIES PUMPS OPERATION & PARTS MANUAL EF SERIES PUMPS OPERATION & PARTS MANUAL EU Declaration of Conformity Finish Thompson Inc. hereby declares that the following machine(s) fully comply with the applicable health and safety requirements

More information

OPERATION AND PARTS MANUAL

OPERATION AND PARTS MANUAL OPERATION AND PARTS MANUAL DRUM PUMPS AND MOTORS HVDP SERIES 1 TABLE OF CONTENTS Introduction...3 Warranty...3 Chemical Reaction Disclaimer...3 Return Policy...3 Safety Precautions...4 Maintenance Precautions...4

More information

Specifications Information and Repair Parts Manual , , , &

Specifications Information and Repair Parts Manual , , , & Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect

More information

Product Catalogue Industrial Pumps & Metering Systems

Product Catalogue Industrial Pumps & Metering Systems Product Catalogue 2017 Industrial Pumps & Metering Systems TABLE OF CONTENTS Applications 4 Pump Packages 5 Drum Pump Motors 9 Pump Tubes (PP, PPS, CPVC, PHT, PVDF) 11 Performance Curves for Centrifugal

More information

M-3025CB-AV Fuel Pump

M-3025CB-AV Fuel Pump SAVE THESE INSTRUCTIONS M-3025CB-AV Fuel Pump Owner s Manual TABLE OF CONTENTS General Information... 2 Safety Instructions... 2 Installation... 3 Operation... 4 Maintenance... 4 Repair... 5 Troubleshooting...

More information

FS Series INSTRUCTION AND MAINTENANCE MANUAL: FS SERIES SHEAR BLENDER. Sanitary Mixing and Blending Equipment

FS Series INSTRUCTION AND MAINTENANCE MANUAL: FS SERIES SHEAR BLENDER. Sanitary Mixing and Blending Equipment FS Series INSTRUCTION AND MAINTENANCE MANUAL: FS SERIES SHEAR BLENDER Sanitary Mixing and Blending Equipment 2 Fristam Pumps DESCRIPTION This manual contains installation, operation, assembly, disassembly

More information

Air Operated Diaphragm Pumps Operating and Maintenance Instructions

Air Operated Diaphragm Pumps Operating and Maintenance Instructions Product & Chemical Disclaimer The user must take responsibility in the selection of the products materials of construction. Empire Pumps Ltd will act in an advisory role and offer recommendations; however,

More information

P/N: DEF-0613A. Diesel Exhaust Fluid (DEF) Pumps

P/N: DEF-0613A. Diesel Exhaust Fluid (DEF) Pumps P/N: DEF-0613A Diesel Exhaust Fluid (DEF) Pumps DEF Solutions Standard Pump has designed a range of unique, preconfigured DEF Pump Packages that are engineered to transfer AdBlue (AUS32) Diesel Exhaust

More information

MV Series Motors Operation & Parts Manual

MV Series Motors Operation & Parts Manual MV Series Motors Operation & Parts Manual Models M3V, M5V, M5V-US For use with M3V s/n 101057 & below, M3V-UK s/n 103013 & below, M5V & M5V-US s/n 102972 & below. EU Declaration of Conformity Finish Thompson

More information

Product Catalogue Industrial Pumps & Metering Systems

Product Catalogue Industrial Pumps & Metering Systems Product Catalogue 2017 Industrial Pumps & Metering Systems TABLE OF CONTENTS Applications 4 Pump Packages 5 Drum Pump Motors 9 Pump Tubes (PP, PPS, CPVC, PHT, PVDF) 11 Performance Curves for Centrifugal

More information

Installation & Operating Manual

Installation & Operating Manual Installation & Operating Manual 25INV-M 1/17 Edition NV Series Vertical Booster Stainless Steel Multistage Centrifugal Pump Congratulations On Your Choice In Purchasing This Webtrol Pump Its Quality is

More information

SHURflo Self-Priming Close-Coupled Centrifugal Pumps In 316 Stainless Steel, Bronze and Cast Iron

SHURflo Self-Priming Close-Coupled Centrifugal Pumps In 316 Stainless Steel, Bronze and Cast Iron Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect

More information

TBP SERIES PUMPS OPERATION & PARTS MANUAL

TBP SERIES PUMPS OPERATION & PARTS MANUAL TBP SERIES PUMPS OPERATION & PARTS MANUAL EU Declaration of Conformity Finish Thompson Inc. hereby declares that the following machine(s) fully comply with the applicable health and safety requirements

More information

Self-Priming Centrifugal Pumps Refer to pump manual for General Operating and Safety Instructions.

Self-Priming Centrifugal Pumps Refer to pump manual for General Operating and Safety Instructions. Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect

More information

Close-Coupled Centrifugal Pumps 316 Stainless Steel, Bronze and Cast Iron Models

Close-Coupled Centrifugal Pumps 316 Stainless Steel, Bronze and Cast Iron Models 316 Stainless Steel, Bronze Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain

More information

OPERATOR S MANUAL A

OPERATOR S MANUAL A OPERATOR S MANUAL 670144-A INCLUDING: OPERATION, INSTALLATION & MAINTENANCE RELEASED: 12-18-15 1/4" DIAPHRAGM PUMP 1:1 RATIO (NON-METALLIC) (REV: A) 67 0144-A READ THIS MANUAL CAREFULLY BEFORE INSTALLING,

More information

Self-Priming Close-Coupled Centrifugal Pumps In 316 Stainless Steel, Bronze and Cast Iron

Self-Priming Close-Coupled Centrifugal Pumps In 316 Stainless Steel, Bronze and Cast Iron Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect

More information

OPERATION MANUAL. ALUMINUM Models. 316 S.S. Models NTG25 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 1/14 rev.

OPERATION MANUAL. ALUMINUM Models. 316 S.S. Models NTG25 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 1/14 rev. OPERATION MANUAL NTG25 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS ALUMINUM Models 316 S.S. Models A JDA Global Company 1/14 rev. 3 CAUTION SAFETY POINTS TEMPERATURE LIMITS: Neoprene -17.8 C to

More information

Polypropylene Piston Drum Pumps

Polypropylene Piston Drum Pumps Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect

More information

1/2" AIR DRIVEN DIAPHRAGM PUMP

1/2 AIR DRIVEN DIAPHRAGM PUMP 1/2" DRIVEN DIAPHRAGM PUMP OPERATION AND SERVICE GUIDE O-1225D NOV. 2008 Page 1 of 6 Refer to Bulletin P-605, Parts List P-9151 DRIVEN, DOUBLE DIAPHRAGM PUMP MANUAL Congratulations on purchasing one of

More information

MV Series Motors Operation & Parts Manual. Models M3V, M5V, M5V-US

MV Series Motors Operation & Parts Manual. Models M3V, M5V, M5V-US MV Series Motors Operation & Parts Manual Models M3V, M5V, M5V-US Introduction This manual pertains to drum pump motors MV Series. Finish Thompson, Inc. thanks you for choosing our products. We believe

More information

AGITATED LID ASSEMBLY

AGITATED LID ASSEMBLY SERVICE MANUAL EN 31-425 AGITATED LID ASSEMBLY 41-3312, 41-3312-S DIRECT DRIVE AGITATORS 77-1474-R20 (3/2018) 1 / 8 www.carlisleft.com AGITATOR ASSEMBLY FOR 25 Litre (5 Gal.) PAIL IMPORTANT: Read and follow

More information

E8 Mini-Matic 3/8" Bolted Plastic Pumps Operating Instructions

E8 Mini-Matic 3/8 Bolted Plastic Pumps Operating Instructions E8 Mini-Matic 3/8" Bolted Plastic Pumps Operating Instructions Polypropylene SAFETY WARNINGS Read these instructions completely before installation and start-up. It is the responsibility of the purchaser

More information

T1-Titanium Non-HVLP Spray Gun

T1-Titanium Non-HVLP Spray Gun T1-Titanium Non-HVLP Spray Gun THE SPRAY GUN PEOPLE FOR PRODUCT INFORMATION CALL: 1-800-742-7731 Important Safety Instructions Read all warnings and instructions in this manual. Save these instructions.

More information

Versa-Matic. Operating Manual. 3/8" Bolted Plastic Pumps. Polypropylene Kynar

Versa-Matic. Operating Manual. 3/8 Bolted Plastic Pumps. Polypropylene Kynar Versa-Matic Operating Manual 3/8" Bolted Plastic Pumps Polypropylene Kynar E8 SAFETY WARNINGS Read these instructions completely before installation and start-up. It is the responsibility of the purchaser

More information

EF SERIES PUMPS EFP, EFS, & EFV OPERATION & PARTS MANUAL

EF SERIES PUMPS EFP, EFS, & EFV OPERATION & PARTS MANUAL EF SERIES PUMPS EFP, EFS, & EFV OPERATION & PARTS MANUAL EU Declaration of Conformity Finish Thompson Inc. hereby declares that the following machine(s) fully comply with the applicable health and safety

More information

1200W INVERTER GENERATOR

1200W INVERTER GENERATOR 1200W INVERTER GENERATOR MODEL NO: IG1200 PART NO: 8877070 OPERATION & MAINTENANCE INSTRUCTIONS LS0117 INTRODUCTION Thank you for purchasing this CLARKE 1200W Inverter Generator. Before attempting to use

More information

TB SERIES PUMPS TBS OPERATION & PARTS MANUAL

TB SERIES PUMPS TBS OPERATION & PARTS MANUAL TB SERIES PUMPS TBS OPERATION & PARTS MANUAL EU Declaration of Conformity Finish Thompson Inc. hereby declares that the following machine(s) fully comply with the applicable health and safety requirements

More information

UV PROCESS SUPPLY, INC. CON-TROL-CURE ½ DIAPHRAGM PUMP INSTRUCTION MANUAL PART # J

UV PROCESS SUPPLY, INC. CON-TROL-CURE ½ DIAPHRAGM PUMP INSTRUCTION MANUAL PART # J 1 IMPORTANT: READ THIS MANUAL CAREFULLY BEFORE INSTALLING, OPERATING OR SERVICING. PUMP DATA TYPE: MAT'L: WEIGHT: Air Operated Double Diaphragm Polypropylene or PVDF or Acetal PVDF (Polyvinylidene Fluoride)

More information

High Head Centrifugal Pedestal Pumps

High Head Centrifugal Pedestal Pumps Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect

More information

701S/R. Watson-Marlow manual control high flow pump Installation and operating instructions. Publication PB 0142 Issue 2.

701S/R. Watson-Marlow manual control high flow pump Installation and operating instructions. Publication PB 0142 Issue 2. 701S/R Drive/s: Issue 4 EPROM: Pumphead/s: N/A Issue1 Watson-Marlow manual control high flow pump Installation and operating instructions Publication PB 0142 Issue 2 Contents Declarations... Page 2 Two-year

More information

855 Filtrate Pump, Close Coupled and Overhead Mounted Pumps

855 Filtrate Pump, Close Coupled and Overhead Mounted Pumps 855 Filtrate Pump, Close Coupled and Overhead Mounted Pumps Technical Specification Pages This page left intentionally blank. 1.0 Overview. The 855 Series is Carver s offering specifically designed to

More information

P SERIES PUMPS. 18mm Versions Nickle-Aluminum Bronze Models: P , P , P , P , P , P , P

P SERIES PUMPS. 18mm Versions Nickle-Aluminum Bronze Models: P , P , P , P , P , P , P P200-3100 SERIES PUMPS 18mm Versions Nickle-Aluminum Bronze Models: P217-3100, P218-3100, P219-3100, P220-3100, P221-3100, P227-3100, P230-3100 Triplex Ceramic Plunger Pump Operating Instructions/ Repair

More information

SB-E-2-CBA1 ISS.13. Operation Manual Cobra 1 Automatic Spray Gun

SB-E-2-CBA1 ISS.13. Operation Manual Cobra 1 Automatic Spray Gun EN SB-E-2-CBA1 ISS.13 Operation Manual Cobra 1 Automatic Spray Gun Operation Manual Cobra 1 Automatic Spraygun Important Read and follow all instructions and Safety Precautions before using this equipment

More information

MICROPUMP MAG-DRIVE GEAR PUMPS

MICROPUMP MAG-DRIVE GEAR PUMPS MAG-DRIVE GEAR PUMPS REVISION # 1 DATE: 6-6-6 WETTED MATERIALS Pump housings: 316 stainless steel. Gears: PEEK. Gear shafts: 316 stainless steel. Gear shaft bearings: PEEK. Driven magnet: Totally encapsulated

More information

PF SERIES PUMPS PFS ATEX VERSION (INCLUDES M6A, M6XA, M10X MOTORS & SPK) OPERATION & PARTS MANUAL

PF SERIES PUMPS PFS ATEX VERSION (INCLUDES M6A, M6XA, M10X MOTORS & SPK) OPERATION & PARTS MANUAL PF SERIES PUMPS PFS ATEX VERSION (INCLUDES M6A, M6XA, M10X MOTORS & SPK) OPERATION & PARTS MANUAL Introduction This manual pertains to the PF Series, specifically the ATEX version of the PFS stainless

More information

E3 3" Bolted Metallic Pumps Operating Instructions

E3 3 Bolted Metallic Pumps Operating Instructions E3 3" Bolted Metallic Pumps Operating Instructions E3 Stainless Steel E3 Hastelloy C E3 Aluminum SPECIFICATIONS AND PERFORMANCE Versa-Matic Model E3 Bolted 3" Pump Flow Rate Adjustable to...... 0-230 gpm

More information

PARTS AND INSTALLATION MANUAL

PARTS AND INSTALLATION MANUAL PSP-3240 POLYPROPYLENE SELF-PRIMING 2 CENTRIFUGAL PUMP PARTS AND INSTALLATION MANUAL PSP-3240 Shown with GX-160 Honda CDS-JOHN BLUE COMPANY DIVISION OF ADVANCED SYSTEMS TECHNOLOGY, INC. 165 Electronics

More information

PUMP-FIT MODEL SERIES PF Assembly, Installation and Operation Manual

PUMP-FIT MODEL SERIES PF Assembly, Installation and Operation Manual PUMP-FIT MODEL SERIES PF66605 Assembly, Installation and Operation Manual EU Declaration of Conformity Pump-Fit hereby declares that the following machine(s) fully comply with the applicable health and

More information

Electric Fuel Pump FPM

Electric Fuel Pump FPM INSTRUCTION MANUAL Electric Fuel Pump FPM S1590, Rev B LISTED MOTOR FPM-12, FPM-24, FPM-115, FPM-220 Congratulations on purchase of this World Class Electric Fuel Pump! Elbow This is an Electric Fuel Pump.

More information

Electric Diesel Pump EDP/12, EDP/24

Electric Diesel Pump EDP/12, EDP/24 INSTRUCTION MANUAL Electric Diesel Pump EDP/1, EDP/4 S1940, Rev C Congratulations on purchase of this World Class Electric Diesel Pump! Portable Diesel transfer pumps designed for everyday use in Agricultural,

More information

HIGH VISCOSITY DRUM PUMPS

HIGH VISCOSITY DRUM PUMPS HIGH DRUM UMS BULLETIN MAY 2005 SR 800 Sanitary INDUSTRIAL & SANITARY UM SERIES Flows to 17 GM / 64 LM Max 174 psi / 12 bar Rugged construction All 316 stainless steel Choice of stater elastomers Industrial

More information

Model SMA3-A SLUDGEMASTER

Model SMA3-A SLUDGEMASTER SERVICE AND OPERATING MANUAL Model SMA3-A SLUDGEMASTER PLEASE NOTE! The photos shown in this manual are for general instruction only. YOUR SPECIFIC MODEL MAY NOT BE SHOWN. Always refer to the parts list

More information

Air Operated Double Diaphragm Pump. M-Pump ½ Metallic Non Metallic Pump INSTALLATION, OPERATION & MAINTENANCE MANUAL

Air Operated Double Diaphragm Pump. M-Pump ½ Metallic Non Metallic Pump INSTALLATION, OPERATION & MAINTENANCE MANUAL Air Operated Double Diaphragm Pump M-Pump ½ Metallic Non Metallic Pump INSTALLATION, OPERATION & MAINTENANCE MANUAL 0.5 I.O.M rev 05. 12/2015 INDEX Title Section Introduction.1 Safety.2 Warranty, General

More information

1100W PORTABLE GENERATOR

1100W PORTABLE GENERATOR 1100W PORTABLE GENERATOR MODEL NO: G1200 PART NO: 8010110 OPERATION & MAINTENANCE INSTRUCTIONS LS0312 INTRODUCTION Thank you for purchasing this CLARKE 1100W Portable Generator. Before attempting to use

More information

Solutions beyond products...

Solutions beyond products... ORIGINAL INSTRUCTIONS IH102C Installation, Operation & Maintenance Manual Model B177 External Automatic Bypass Valve Model B177 External Automatic Bypass Valve Warning: (1) Periodic inspection and maintenance

More information

IMPORTANT!!!! Read this manual before attempting any installation, wiring or operation.

IMPORTANT!!!! Read this manual before attempting any installation, wiring or operation. Industrial Turbo Meters Sizes 2" through 6" Installation & Operation Manual IMPORTANT!!!! Read this manual before attempting any installation, wiring or operation. BadgerMeter,Inc. IOM-003-15 Part No.

More information

TM SERIES MIXER TMS OPERATION & PARTS MANUAL

TM SERIES MIXER TMS OPERATION & PARTS MANUAL TM SERIES MIXER TMS OPERATION & PARTS MANUAL EU Declaration of Conformity Finish Thompson Inc. hereby declares that the following machine(s) fully comply with the applicable health and safety requirements

More information

REPAIR SEALS AND OPTIONS

REPAIR SEALS AND OPTIONS Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect

More information

OPERATION MANUAL NT50 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 7/11 rev. 1

OPERATION MANUAL NT50 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 7/11 rev. 1 OPERATION MANUAL NT50 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS A JDA Global Company 7/11 rev. 1 CAUTION SAFETY POINTS TEMPERATURE LIMITS: Neoprene -17.8 C to 93.3 C 0 F to 200 F Buna-N -12.2

More information

CLOSED COUPLED CENTRIFUGAL PUMPS

CLOSED COUPLED CENTRIFUGAL PUMPS SECTION B PAGE 0 ISSUED /0 REPLACES /0 www.pumpagents.com PumpAgents.com - Click here for Pricing/Ordering SERIES: G6--/ thru G9-F 0 Third Street Piqua, Ohio 6-060 CLOSED COUPLED CENTRIFUGAL PUMPS 00RPM

More information

ATD-6810 SPRAY GUN W/CUP INSTRUCTION MANUAL

ATD-6810 SPRAY GUN W/CUP INSTRUCTION MANUAL ATD-6810 SPRAY GUN W/CUP INSTRUCTION MANUAL Read this Instruction Manual carefully and understand it completely, basic precaution should be strictly followed to prevent the damage to the tool and injury

More information

OPERATOR S MANUAL C INCLUDING: OPERATION, INSTALLATION & MAINTENANCE RELEASED:

OPERATOR S MANUAL C INCLUDING: OPERATION, INSTALLATION & MAINTENANCE RELEASED: OPERATOR S MANUAL 650719-C INCLUDING: OPERATION, INSTALLATION & MAINTENANCE RELEASED: 8-11-03 REVISED: 12-3-10 (REV. 08) 2" DIAPHRAGM PUMP U.L. LISTED, 1:1 RATIO, METALLIC READ THIS MANUAL CAREFULLY BEFORE

More information

Stub pump 3:1. User and maintenance instructions. Models and , series D. Date of issue December Form number

Stub pump 3:1. User and maintenance instructions. Models and , series D. Date of issue December Form number User and maintenance instructions Stub pump 3: Models 282396 and 282398, series D Date of issue December 207 Form number 404099 Section Page A6 37V Contents Safety........................... 2 Explanation

More information

Air-Operated Double-Diaphragm Pump

Air-Operated Double-Diaphragm Pump Air-Operated Double-Diaphragm Pump Owner s Manual WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety

More information

Operation Manual Cobra 1 Automatic Spray Gun

Operation Manual Cobra 1 Automatic Spray Gun SB-E-2-CBA1 ISS.06 Operation Manual Cobra 1 Automatic Spray Gun E P 1 12 1 Operation Manual Cobra 1 Automatic Spraygun Important Read and follow all instructions and Safety Precautions before using this

More information

Mounting and Operating Instructions EB 8039 EN. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve

Mounting and Operating Instructions EB 8039 EN. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve Type 3351 Pneumatic On/off Valve Type 3351 Pneumatic On/off Valve Type 3351 Pneumatic On/off Valve Version with handwheel Mounting and Operating Instructions EB 8039 EN Edition May 2016 Definition of signal

More information

KP-C Series. Close Coupled End Suction Centrifugal Pumps. Installation, Operation and Maintenance

KP-C Series. Close Coupled End Suction Centrifugal Pumps. Installation, Operation and Maintenance KP-C Series Close Coupled End Suction Centrifugal Pumps Installation, Operation and Maintenance PUMP MODEL NOMENCLATURE KP - 8 x 6 x 16 - E C - AI - BCM Pump Series Suction Pipe Size (in) Discharge Pipe

More information

Air operated chassis pump

Air operated chassis pump User and maintenance instructions Air operated chassis pump Models 84667 and 84668, series A Date of issue June 207 Form number 40354B Contents Description....................... 2 Safety information................

More information

H2O-C14 AAA FINE FINISH SERIES PUMP OUTFIT

H2O-C14 AAA FINE FINISH SERIES PUMP OUTFIT PRODUCT INFORMATION H2O-C14 AAA FINE FINISH SERIES PUMP OUTFIT The H2O-C14 AAA pump system is an air assisted airless unit which combines airless and conventional or HVLP air atomization technologies to

More information

PF SERIES PUMPS PFS OPERATION & PARTS MANUAL

PF SERIES PUMPS PFS OPERATION & PARTS MANUAL PF SERIES PUMPS PFS OPERATION & PARTS MANUAL For Serial Number 162859 & above EU Declaration of Conformity Finish Thompson Inc. hereby declares that the following machine(s) fully comply with the applicable

More information

Disc Grinder Model G 18MR G 23MR G 23MRU

Disc Grinder Model G 18MR G 23MR G 23MRU Disc Grinder Model G 18MR G 23MR G 23MRU Handling instructions G23MR NOTE: Before using this Electric Power Tool, carefully read through these HANDLING INSTRUCTIONS to ensure efficient, safe operation.

More information

Ph: (07) Fax: (07) Pump Manual

Ph: (07) Fax: (07) Pump Manual sales@scintex.com.au www.scintex.com.au Ph: (07) 3137 0135 Fax: (07) 3041 0541 Pump Manual 12V 75LPM Vane Pump & Vane Pump Station SPEP12V75 & SP12VFS75 SPEP12V75 SP12VFS75 Parts List No. Part Name QTY

More information

Pressure relief valve

Pressure relief valve Pressure relief valve Operating manual Series DHV 712 Version BA-2015.10.20 EN Print-No. 300 510 TR MA DE Rev001 ASV Stübbe GmbH & Co. KG Hollwieser Straße 5 32602 Vlotho Germany Phone: +49 (0) 5733-799-0

More information

Industrial Turbo Meters, Sizes 2" through 6"

Industrial Turbo Meters, Sizes 2 through 6 Industrial Turbo Meters Sizes 2" through 6" TUR-UM-00530-EN-19 (October 2014) User Manual Industrial Turbo Meters, Sizes 2" through 6" User Manual CONTENTS Scope of the Manual 5 Specifications 5 Product

More information

Model and Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS. PumpAgents.com - buy pumps and parts online INDUSTRIAL DIAPHRAGM PUMPS

Model and Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS. PumpAgents.com - buy pumps and parts online INDUSTRIAL DIAPHRAGM PUMPS Model 31801 and 31800 Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS INDUSTRIAL DIAPHRAGM PUMPS FEATURES Run Dry Ability Self-Priming Thermal Overload Protected Motor Easy Installation Low Amp Draw Compact

More information

SHURflo Close-Coupled Centrifugal Pumps

SHURflo Close-Coupled Centrifugal Pumps Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect

More information

OWNER/OPERATOR MANUAL. Airmotor effective dia. in. 2.5

OWNER/OPERATOR MANUAL. Airmotor effective dia. in. 2.5 MODELS 282050, 282716 & 283513 AIR OPERATED CHASSIS PUMP SERIES A OWNER/OPERATOR MANUAL SPECIFICATIONS Airmotor effective dia. in. 2.5 Airinlet Material outlet 1/4 NPTF 1/4 NPTF Liquid to Air Pressure

More information

CLOSED COUPLED CENTRIFUGAL PUMPS

CLOSED COUPLED CENTRIFUGAL PUMPS 40 Third Street Piqua, Ohio 4556-060 www.pumpagents.com PumpAgents.com - Click here for Pricing/Ordering SERIES G5--/4 G6--/4 SECTION B PAGE ISSUED /0 REPLACES /0 CLOSED COUPLED CENTRIFUGAL PUMPS 500RPM

More information

EF SERIES EFS ATEX VERSION (INCLUDES OPTIONAL S4A MOTOR & SPK) OPERATION & PARTS MANUAL

EF SERIES EFS ATEX VERSION (INCLUDES OPTIONAL S4A MOTOR & SPK) OPERATION & PARTS MANUAL EF SERIES EFS ATEX VERSION (INCLUDES OPTIONAL S4A MOTOR & SPK) OPERATION & PARTS MANUAL Introduction This manual pertains to the EF Series, specifically the ATEX version of the EFS stainless steel drum

More information

CLOSED COUPLED CENTRIFUGAL PUMPS

CLOSED COUPLED CENTRIFUGAL PUMPS SECTION B PAGE 0 ISSUED /0 REPLACES /0 www.pumpagents.com PumpAgents.com - Click here for Pricing/Ordering SERIES: G6--/ thru G9-F 0 Third Street Piqua, Ohio 6-060 CLOSED COUPLED CENTRIFUGAL PUMPS 00RPM

More information

SAFETY MANUAL READ FIRST!

SAFETY MANUAL READ FIRST! 966-05-XX SAFETY MANUAL READ FIRST! IMPORTANT: READ THESE WARNINGS AND SAFETY PRECAUTIONS PRIOR TO INSTALLATION OR OPER- ATION. FAILURE TO COMPLY WITH THESE INSTRUC- TIONS COULD RESULT IN PERSONAL INJURY

More information

MODEL EGA200 OWNERS MANUAL

MODEL EGA200 OWNERS MANUAL 3/8 RATCHET WRENCH MODEL EGA200 OWNERS MANUAL www.eaglecompressor.com 1-800-551-2406 READ THE ENTIRE MANUAL BEFORE PUTTING THIS TOOL IN SERVICE Limited Air Tool Warranty Wood Industries, Inc. warrants

More information

Model No. SP Low Volume Low Pressure (LVLP) Gravity Feed Spray Gun

Model No. SP Low Volume Low Pressure (LVLP) Gravity Feed Spray Gun Model No. SP-33000 Low Volume Low Pressure (LVLP) Gravity Feed Spray Gun - 1 - TABLE OF CONTENTS: 1. Description 2. Specification and Technical Data 3. Important Safety Instruction 4. Instructions for

More information

Electric Fuel Pump FPM

Electric Fuel Pump FPM INSTRUCTION MANUAL Electric Fuel Pump FPM S1590, Rev B LISTED MOTOR FPM-12, FPM-12/HF, FPM-24, FPM-115, FPM-220 Congratulations on purchase of this World Class Electric Fuel Pump! Pump Outlet Elbow Nozzle

More information

Installation, Operation & Maintenance Manual

Installation, Operation & Maintenance Manual IH106 Installation, Operation & Maintenance Manual ZV200 Bypass Valve Model ZV200 Bypass Valve Warning: (1) Periodic inspection and maintenance of Corken products is essential. (2) Inspection, maintenance

More information

FPR Series Pump INSTRUCTION AND MAINTENANCE MANUAL: FPR SERIES PUMP. Sanitary Centrifugal Pump

FPR Series Pump INSTRUCTION AND MAINTENANCE MANUAL: FPR SERIES PUMP. Sanitary Centrifugal Pump FPR Series Pump INSTRUCTION AND MAINTENANCE MANUAL: FPR SERIES PUMP Sanitary Centrifugal Pump Fristam Pumps 2 DESCRIPTION This manual contains installation, operation, assembly, disassembly and repair

More information

Bypass / Filter Feeders Operations & Maintenance Manual

Bypass / Filter Feeders Operations & Maintenance Manual Bypass / Filter Feeders Operations & Maintenance Manual Record Your Model, Serial Number and Other Information on the back of this document. Manufacturing: Bypass & Filter Feeders, Glycol Feed Packages,

More information

PF SERIES PUMPS PFM, PFP, PFV OPERATION, INSTALLATION & PARTS MANUAL

PF SERIES PUMPS PFM, PFP, PFV OPERATION, INSTALLATION & PARTS MANUAL PF SERIES PUMPS PFM, PFP, PFV OPERATION, INSTALLATION & PARTS MANUAL EU Declaration of Conformity Finish Thompson Inc. hereby declares that the following machine(s) fully comply with the applicable health

More information

Model SLUDGEMASTER SMA3-A

Model SLUDGEMASTER SMA3-A SERVICE AND OPERATING MANUAL Model SLUDGEMASTER SMA3-A OPERATING INSTRUCTIONS This pump has been tested prior to shipment from factory. The oil reservoir has been partially filled at testing with air motor

More information

Cast Iron Rotary Drum Pump

Cast Iron Rotary Drum Pump Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect

More information

PRESSURE REDUCING CONTROL VALVE

PRESSURE REDUCING CONTROL VALVE PRESSURE REDUCING CONTROL VALVE 06/08 Schematics Throttles to reduce high upstream pressure to constant lower downstream pressure Reducing setpoint is adjustable 2 (AOS) X P/L Standard Components 1 Main

More information

PF SERIES PUMPS PFS ATEX VERSION (INCLUDES M6A, M6XA, M10X MOTORS & SPK) OPERATION & PARTS MANUAL

PF SERIES PUMPS PFS ATEX VERSION (INCLUDES M6A, M6XA, M10X MOTORS & SPK) OPERATION & PARTS MANUAL PF SERIES PUMPS PFS ATEX VERSION (INCLUDES M6A, M6XA, M10X MOTORS & SPK) OPERATION & PARTS MANUAL Introduction This manual pertains to the PF Series, specifically the ATEX version of the PFS stainless

More information

High Performance Vacuum Pump Model 15120A/15121A Operating Manual...

High Performance Vacuum Pump Model 15120A/15121A Operating Manual... High Performance Vacuum Pump Model 15120A/15121A Operating Manual... Operating Manual Table of Contents Warnings...1 CoolTech high performance vacuum pumps...1 Pump components...2 Before using your vacuum

More information

DIFFERENTIAL PRESSURE RELIEF REGULATOR TYPE A4AL Port Size 3/4"- 4" (20-100mm) For Ammonia, R-22, R134a, R404a, R507 and other common refrigerants.

DIFFERENTIAL PRESSURE RELIEF REGULATOR TYPE A4AL Port Size 3/4- 4 (20-100mm) For Ammonia, R-22, R134a, R404a, R507 and other common refrigerants. DIFFERENTIAL PRESSURE RELIEF REGULATOR TYPE A4AL Port Size 3/4"- 4" (20-100mm) For Ammonia, R-22, R134a, R404a, R507 and other common refrigerants. FEATURES Pilot operated characterized Modulating Plug

More information

1004D2/1005E API Bottom Loading Coupler. 1005E Small handles used throughout Europe 1004D

1004D2/1005E API Bottom Loading Coupler. 1005E Small handles used throughout Europe 1004D PART #H32183PA February 2009 1004D2/1005E API Bottom Loading Coupler The 1004D2 is the standard in drip-less bottom loading couplers and a proven performer at major oil terminals worldwide. The 1004D2

More information

WARNING CAUTION. CAUTION Do not exceed 120 psig (8.3 bar) air-inlet pressure.

WARNING CAUTION. CAUTION Do not exceed 120 psig (8.3 bar) air-inlet pressure. 13966-300-BM SAFETY MANUAL READ FIRST! IMPORTANT: READ THESE WARNINGS AND SAFETY PRECAUTIONS PRIOR TO INSTALLATION OR OPER- ATION. FAILURE TO COMPLY WITH THESE INSTRUC- TIONS COULD RESULT IN PERSONAL INJURY

More information