DOMINO For chemical liquids
|
|
- Beverly O’Connor’
- 5 years ago
- Views:
Transcription
1 DOMINO For chemical liquids Applications Flow measurement of liquids in chemical, chemotechnical, pharmaceutical, cosmetic and other industries. Batching and filling operations. Your Benefits Product versions for safe areas or for hazardous areas (ATEX) Modular products with wide range of flow sensors, displays, pulsers and batching controls Mechanical, pneumatic and electronic batching controls Highly flexible mounting with least space requirements Suitable for both conductive and non conductive liquids Flow disturbances do not influence proper operation and accuracy Long life with low maintenance VD 5 e Features sales@mvandc.com Phone: Fax:
2 DOMINO the modular flow measurement concept System overview Page 4 ARD rotary piston flowmeters for Nominal diameter DN 5,,, and 50 mm Operating pressures PN 0, 6, or Fluid temperatures up to 80 C Modular meter concept in various materials Measuring error limits ± 0,5 % of effective value For high viscosity range up to about mpa s Swivelling roller register for optimal readability Specialpurpose calibrations for differential pressure measurement (optional) All flowmeters available with various modules according to need Page 9 AMD vane wheel flowmeters for Nominal diameter DN and with flanged connections Operating pressure PN Fluid temperatures up to C, special versions up to 80 C For low viscosity range up to 4 mpa s Measuring error limits ± 2 % of effective value (± 5 % at lower end of measuring range) All flowmeters available with various modules according to need Page 5 PMD vane wheel flowmeters for Nominal diameter DN, and with threaded connections Operating pressure PN 6 Fluid temperatures up to C Primarily for water, also for nonaggressive lowviscosity fluids up to4 mpa s Measuring error limits ± 2 % of effective value (± 5 % at lower end of measuring range) All flowmeters available with various modules according to need Page sales@mvandc.com Phone: Fax:
3 VZTH 8 rotary piston flowmeter for In addition to the DOMINO range, a flowmeter is also available for lower flows. For detailed technical data, please see our separate Technical Documentation. Pulsers Page System planning Page 2 Ordering information Page 23 Accreditations Page 28 sales@mvandc.com Phone: Fax:
4 System overview Meter Ancillaries display in volumetric units (litre or m3), special version with display in USGallons available with pulser, roller counter or for batching devices RW Roller register local totalization RV Roller register with integral reedtype pulser local totalizing pulser for remote totalizing not for use in hazardous areas! AM06633 IN Inductive pulser for industrial control systems to IEC different resolutions for hazardous location Zone (ATEX version) roller register INA Inductive pulser for industrial control systems to IEC high resolution for analogue signal generation or input to electronic batching controls for hazardous location Zone (ATEX version) optional roller register AM Measuring Units different measuring principles (ARD, AMD and PMD) various materials according to the meter type (stainless steel, cast iron, brass, plastics) flanges according to DIN (in general also available with ANSI orjis borings) AM06646 ARD Rotary Piston Meters for chemical liquids Nominal diameter 5,,,, 50 mm Nominal pressure 0,6,, bar Temperature, 50,, 30, 80 C Flow rate sales@mvandc.com Phone: Fax:
5 Accessories batching devices for manual, semiautomatic and automatic control MSKP Mounting set for compact mounting F3 AM06638 AM06639 GTAS module Intermediate drive for AS or ASP batching control INA module Pulser for electronical batching units AM06667 AM06666 AM AM AMD Vane Wheel Meters for chemical liquids Nominal diameter, mm Nominal pressure 6, bar Temperature, 80 C Flow rate PMD Vane Wheel Meters for cold and hot water / batching Nominal diameter,, mm Nominal pressure 6 bar Temperature C Flow rate sales@mvandc.com Phone: Fax:
6 Applications ARD rotary piston flowmeters for pure chemical liquids of various types AMD vane wheel flowmeters for chemical liquids PMD vane wheel flowmeters for water (in particular for dosing) Selection of commonly measured liquids Acetic acid Acetone Animal fats Ammonium hydroxide, ammonia solutiuon Bromium hydroxide, bromic acid Butyl acetate, acetic butyl ester Chloroform, trichloromethane Citric acid Ethyl acetate, acetic ether, acetic ester Ethyl alcohol, alcohol, ethanol Ethyl ethylene, ethylene, diethyl ethylene Ethylene glycol Formaldehyde solution Formic acid Glycerine Hexine Hydrochloric acid Hydrofluoric acid Hydrogen peroxide, hydrogen superoxide Isopropyl ether, diisopropyl ether Isopropyl alcohol, propyl alcohol 6 Magnesium sulphate Methanol, methyl alcohol) Methylene chloride, dichloromethylene Methyl ethyl ketone Molasses (without urea) Nitric acid Diethylene glycol Distilled water Kerosine, petroleum Liquid ammonia Liquid bromium Liquid butane Paraffin Perchloroethylene, tetrachloroethylene Phosphoric acid Potassium hydroxide, caustic potash Propionic acid Prussic acid Pure benzol Sodium chloride solution, brine Sodium hydroxide, caustic soda solution Sodium hypochlorite solution, Javelle water Sulfocarbonic acid Sulphuric acid Tar, pitch Tetrachloromethane, carbon tetrachloride Toluene Trichloroethylene (dry) Vegetable oils sales@mvandc.com Phone: Fax:
7 Operation principles ARD range Works on the volumetric principle with rotary pistons Wide measuring range with high precision Suitable for high viscosities Insensitive to flow disturbances No power supply needed AMD and PMD series Works on the velocity measuring principle with multijet vane wheel Extremely wide measuring range with good accuracy Largely insensitive to slight impurities in liquid media Insensitive to flow disturbances No power supply needed Design features ARD range AMD and PMD series The only moving parts in contact with the liquid medium The only moving part in contact with the liquid medium is the vaneare the rotary piston, guide rollers and carrier. The hydraulic wheel. In AMD models this is mounted between bearings, and measuring module iscompletely isolated from the roller in PMD models on ruby bearings. This ensures years of easy running register, and signals are transmitted magnetically through and high precision, long life and excellent longterm stability of the the sealed cover of the measuring chamber. measuring characteristic. For optimal readability, the roller register can be swivelled The hydraulic measuring module is completely isolated from the rolthrough 360 on versions without RV integral pulser. lerregister, and signals are transmitted magnetically through the sealed cover of the measuring chamber. For optimal readability, the roller register can be swivelled through 360 on versions without RV integral pulser. AM06669 AM Phone: Fax:
8 Permissible measuring error under reference conditions ARD rotary piston flowmeters Reference conditions: Group A Medium: Water Temperature: C Group B calibration oil (5 mpa s at C) 8... C Group A comprises the flowmeter with rotary pistons of vulcanized rubber, graphite or. Group B has rotary pistons of aluminium or stainless steel. Measuring tolerance Horizontal meter mounting, reading on register +0,5% 0,5% AM06696e Qmin % Qmax Flow DOMINO ARD rotary piston flowmeters have an infinitely adjustable regulation mechanism for correcting the measuring error curve. So if necessary the measuring tolerance can be set to practically zero at constant flow either on site or by special works calibration. AMD and PMD vane wheel flowmeters Reference conditions: Medium: Water Temperature: C Measuring tolerance Horizontal meter mounting, reading on register +2% 0 AM06670e 2% Qmin % Qmax Flow 8 sales@mvandc.com Phone: Fax:
9 DOMINO ARD rotary piston flowmeters Technical data For chemical liquids with viscosities up to about mpa s For horizontal or vertical installation Measuring error limits ±0.5 % of effective value, repeatability ±0. % Max. temperature, 50,, 30 or C (according to version) Max. pressure 0, 6, or bar (according to version) Threaded connections (brass housing) Combinable with all DOMINO modules Special versions with units of measurement in US gallons or with different flangestandards (JIS, ANSI) on request Nominal diameter DN Overall length Rated max. pressure with threated connections ARD 000 Rated max. pressure with flanged connections ARD 000 ARD 00 ARD 3000 ARD 00 Maximum flow rate 2) Qmax Flow in batching mode Qch Continuous flow rate 2) Qn Minimal flow rate 3) Qmin Starting flow rate approx. 3) Smallest registered value 4) Metering capacity 4) Metering time at Qn without overflow 4) Safety filter mesh size Dirt trap filter mesh size Measuring chamber volume Housing finish Weight 5) ARD 000 threaded ARD 000 flanged ARD 00 flanged ARD 3000 flanged ARD 00 flanged mm inch mm 5 /2 65 3/4 65 ) / bar bar bar bar bar l m3/h h mm mm cm enamelled yellow RAL kg kg kg kg kg ) Overall lengh with housing is 260 mm. 2) Flowrates for heating oil are higher. For particular data see Technical Documentation CONTOIL oil flowmeter. 3) Qmin and starting flowrates are valid for material combination: brass housing / aluminium pistons for EL heating oil. Qmin for other material combination see table below: "Measuring range as a function of material combination". 4) For roller register. 5) Meter weight depends on material combinations and modules. Data given are typical for meters with roller register. Measuring range as a function of material combination Qmin in % of Qmax with measuring error limits ± 0.5 %. Type ARD 000 ARD 00 ARD 3000 ARD 00 Measuring chamber Brass Stainless steel Stainless steel Rotary piston Aluminium 2.5 % 2.5 % Hard rubber 5% 5% Graphite 5% 5% 5% Stainless steel 5% 5% sales@mvandc.com Phone: Fax: % 0 % 0 % 0 % 9
10 Measuring sensors and materials Type ARD 000 ARD 00 ARD 3000 ARD 00 * Component Housing Measuring chamber Seals Rotary pistons Housing Measuring chamber Seals Rotary pistons Housing Measuring chamber Seals Rotary pistons Housing Measuring chamber Seals Rotary pistons Material Brass (threaded connections) or spherolitic cast iron (threaded or flanged connections) Brass / PPS (30 C) or brass / (80 C) FPM (fluoroelastomer) Aluminium, hard rubber, graphite or Spherolitic cast iron Stainless steel* / PPS (30 C) or stainless steel* / (80 C) FPM or (fluoroelastomer or polytetrafluoroethylene) Hard rubber, graphite, stainless steel* or Stainless steel* Stainless steel* / FPM or (fluoroelastomer or polytetrafluoroethylene) Hard rubber, graphite, stainless steel* or with metal sleeving / Tantal with metal sleeving FFKM (Perfluoroelastomer) Corrosion and acidresistant steel (CrNiMo) to DIN.48 /.4435 / sales@mvandc.com Phone: Fax:
11 Pressure drop curves DN 5 DN I H G Pressure drop in mbar H G 0 F E 00 Pressure drop in mbar 00 I F E 0 D D C C B A A Flow in 56543e 56542e 0 Qmin Qmax 0 00 Flow in Qmin 30 DN Qmax 500 DN I I H G 0 00 Pressure drop in mbar Pressure drop in mbar 00 F H G F 0 E D E C D C A A Flow in 56545e 56544e 0 00 Qmin Qmax 3000 Flow in 00 Qmin Qmax 00 DN 50 Recommended pressure drop max. bar Admissible pressure drop max. 3 bar Viscosities: Pressure drop in mbar I 00 A B C D E F G H I H G 0 F E D C 0. A = 4.5 mpa s = mpa s = 50 mpa s = 00 mpa s = 0 mpa s = 500 mpa s = 000 mpa s = 00 mpa s = 5000 mpa s 56546e Flow in Qmin Qmax sales@mvandc.com Phone: Fax:
12 Flowmeter unit dimensions in mm ARD 000 with threaded connections DN 5,, a a øf AM06658 AM b b r p c r p c DN, 50 d øf AM06657 d AM06660 b b øf c Øf c ARD 000, 00, 3000 with flanged connections (to DIN 0) DN 5,, DN, 50 øf ARD 5 ARD ARD ARD ARD 50 a AM06656 DN 5 50 AM06655 a a AM06662 b c d Øf Øf AM0666 p G 3/4 G G /4 G 2 G 2 3/8 r G /2 G 3/4 G G /2 G 2 b b øf c øf c ARD 00 with flanged connections (to DIN 0 / SN 2843) DN DN Øf a ARD ARD DN a a AM06654 AM0665 b c Øf AM06653 Øf 5 50 RW, RV roller registers and dials Ø05 RV with integrated pulser (reed type) max. 80 C RW roller register only max. 80 C Ø05 2 AM06633a sales@mvandc.com Phone: Fax:
13 DN,, DN 50, 0 m3 x 0. x x 0.0 x 0.0 x 0. x 0.00 AM06607 Dials DN 5 Pulsers Technical data For further technical data and wiring diagrammes, see sections "Pulsers" (page ) and Remote pulse transmission (page 22). Pulse values Pulser type IN IN INA RV Inductive switch (NAMUR) Inductive switch (NAMUR) ) Inductive switch (NAMUR) ) 2) Reed switch approx. mm inch l/pulse l/pulse l/pulse l/pulse l/pulse Nominal diameter of measuring unit 5 /2 3/ / ) High temperature versions are desigated with H. 2) The exact pulse value is indicated on the meter. Since this value is not known before calibration, the connected unit must have an adaptable input. Versions with 2 pulsers on request. Pulse frequencies IN IN INA INA at Qmax at Qmin at Qmax at Qmin Hz Hz Hz Hz IN / INH Inductive pulser according to IEC (NAMUR) with roller register INH max. 80 C 80.5 IN max. 30 C Ø Ø05 57 AM sales@mvandc.com Phone: Fax:
14 INA / INAH Inductive pulser according to IEC (NAMUR) with high resolution INAHRW with RW (roller register) max. 80 C Ø05 Ø05 Ø05 57 INARW with RW (roller register) max. C 48 INAH without RW (roller register) max. 80 C 94.5 INA without RW (roller register) max. C Ø AM06630 AS / ASP mechanical batching controls GTAS module for AS / ASP max. 80 C GTAS with dosing control (optional) with AS 0, all other AS max. 80 C max. 80 C with ASP max. 80 C º AM AM 0664 Ø05 AM º For technical data on AS / ASP batching control modules see separate Technical Documentation. Options for external electronic batching controls max. C max. 80 C INA / RD.. recommended (others also possible) INAH / RD.. recommended (others also possible) Wall or front panel mounting ATEX Directive With the exception of the RV... ancillary groups, all DOMINO components are certified according to ATEX Directive 94/9/EC. Marking: II2G ct6 The ECTypeExamination Certificate is available on our website. 4 sales@mvandc.com Phone: Fax:
15 DOMINO AMD vane wheel flowmeters Technical data Nominal diameter DN Overall length Rated pressure PN Max. temperature Maximum flow rate Continuous flow rate Transitional flow rate Minimal flow rate With AS 0 filling control: Transitional flow rate Minimal flow rate Smallest registered value Metering capacity Metering time at Qn without overflow Safety filter mesh size in meter base Housing finish Weight Tmax Qmax Qn Qt Qmin Qt Qmin For chemical liquids with viscosities up to about 4 mpa s For horizontal installation dial upward Measuring error limits ±2 % of effective value ), repeatability ±0.3 % Temperature C, 80 C Rated pressure PN Housing with flanged connections to DIN 0 / SN Combinable with all DOMINO modules Special versions with other flange holes on request mm inch mm bar C 65 resp /2 300 resp l 0. m3/h h mm 2.5 enamelled yellow RAL 007 kg ) ± 5 % at lower end of measuring range between Qmin and Qt. Measuring module materials Component Housing Measuring unit Seals Vane wheel bearings DN mm Materials Stainless steel* Stainless steel* ( C), graphite (80 C) Corrosion and acidresistant steel (CrNiMo) to DIN.48 / Pressure drop in mbar * Pressure drop characteristics 0 AM06679e Flow in m3/h sales@mvandc.com Phone: Fax:
16 Measuring module dimensions in mm AMD DN 8 64 Ø DN M A Ø38 AM AM Flanges to DIN 0 / SN 2843 AM06682 RW, RV roller registers and dials Ø05 RV with integrated pulser (reed type) max. 80 C Dials DN, 06, RW roller register only max. 80 C Ø05 AM06633a AM06645 Pulsers Technical data For further technical data and wiring diagrammes, see sections "Pulsers" (page ) and Remote pulse transmissions (page 22). Pulse values Pulser type ) RV IN Reed switch Inductive switch (NAMUR) INA Inductive switch (NAMUR) approx. mm inch l/pulse l/pulse l/pulse l/pulse Nominal diameter of measuring unit / Hz Hz Hz Hz ) High temperature versions are designated with H. Pulse frequencies IN 0. at Qmax at Qmin INA at Qmax at Qmin sales@mvandc.com Phone: Fax:
17 INAH max. 80 C INA max. C Ø05 Ø05 AM Ø IN max. 30 C High resolution INA inductive pulser according to IEC (NAMUR) 94.5 Pulser modules IN inductive pulser according to IEC (NAMUR) 57 AS / ASP mechanical batching controls GTAS module for AS / ASP max. 80 C GTAS with dosing control (optional) with AS 0, all other AS max. 80 C max. 80 C with ASP max. 80 C º AM AM 0664 Ø05 AM º Ignition protection type "constructional safety c". For technical data on AS / ASP batching control modules see separate Technical Documentation. Options for external electronic batching controls max. C max. 80 C INA / RD.. recommended (others also possible) INAH / RD.. recommended (others also possible) Wall or front panel mounting ATEX Directive With the exception of the RV... ancillary groups, all DOMINO components are certified according to ATEX Directive 94/9/EC. Marking: II2G ct6 The ECTypeExamination Certificate is available on our website. sales@mvandc.com Phone: Fax:
18 DOMINO PMD vane wheel flowmeters Technical data Nominal diameter DN Overall length Rated pressure PN Max. temperature Maximum flow rate Continuous flow rate Transitional flow rate Minimal flow rate With AS 0 filling control: Transitional flow rate Minimal flow rate Smallest registered value Metering capacity Metering time at Qn without overflow Safety filter mesh size in meter base Housing thread Screw connection thread Housing finish Weight without screw connections Tmax Qmax Qn Qt Qmin Qt Qmin Primarily used for water flow measurement or dosing Brass housing with threaded connections or threaded flanges For horizontal installation dial upward Measuring tolerances ± 2 % of effective value ), repeatability ± 0.3 % Temperature max. C Rated pressure 6 bar Available only with modules "pulser with roller register" or "installation for batching control". mm inch mm bar C 3/ l 0. m3/h h 000 mm.5 inch inch 3/4 enamelled yellow RAL 007 kg / / / ) ± 5 % at lower end of measuring range between Qmin and Qt. Measuring module materials Component Housing Measuring unit Seals Vane wheel bearings Materials Brass PPO plastic EPDM (ethylene propylene) Plastic and synthetic ruby balls Pressure drop characteristics DN mm AM06684 Pressure drop in mbar Flow in m /h 8 sales@mvandc.com Phone: Fax:
19 Measuring module dimensions in mm Dials DN,, Øf a d DN a b c PMD PMD PMD Module installation heights are given in sections AMD modules AM AM b p Øf r c, d AM06645 Øf Øf p G G /4 G 2 r G 3/4 G G /2 Pulsers Technical data For further technical data and wiring diagrammes, see sections "Pulsers" (page ) and Remote pulse transmissions (page 22). Pulse values Nominal diameter of measuring unit Pulser type IN Inductive switch (NAMUR) INA Inductive switch (NAMUR) approx. mm inch l/pulse l/pulse l/pulse 3/ / Hz Hz Hz Hz Pulse frequencies IN INA at Qmax at Qmin at Qmax at Qmin AS/ASP mechanical batching controls: Same specifications and dimensions as for AMD (page 7). For external electronic batching controls: Same specifications and dimensions as for AMD (page 7). ATEX With the exception of the RV... ancillary groups, all DOMINO components are available with ATEX approval according to Directive 94/9/EC for use in hazardous locations zone. Classification II 2G c T6 (pulsers IN, INH, INAH: EEx ia IIC T6). sales@mvandc.com Phone: Fax:
20 Pulsers IN: Inductive pulser with decadic pulse values INA: Highresolution inductive pulser IN, INA pulser module Switching element: Switching voltage: Residual ripple: Switching current: Static current: Switchon time: Ambient temperature: Protection class: Use in explosion risk zones: Connections: Wiring diagramme AM 0662 Pulser types IN, INA for industrial applications Slotted disc initiator according to IEC V DC max. 5 % > 3 ma (at 8 V DC, KOhm) < ma (at 8 V DC, KOhm) 50 ± 0% C IP 65 (IEC 60529) against waterjets and dust Available with ATEX Certificate II 2 G EEx ia IIC T6 for use in hazardous areas Connect cabel (min. 2 x 0.35 mm2) to pulser probe with plug provided. Cable outer diameter mm. For use in explosion risk zones are preferably light blue cables to be used. See local regulations for Ex risk use! RV: Reed pulser with decadic pulse values RV pulser for remote totalizing integrated in roller register Wiring diagramme +/ Ri 47 Oh m +/ This simple version of a reed pulser is suitable for remote totalizing. For industrial control systems the IN or INA versions are recomended. Electronic pulse counters have low switching power consumption. They are therefore energized directly from the pulser. Electromechanical pulse counters with power consumption exceeding 2 W require an intermediate switching relay (e.g. WE 77). Switching element: Switching voltage: Switching current: Static current: Switching power: Ambient temperature: Protection class: Connection: Reed contact tube filled with inert gas max. 48 V AC or DC max. 50 ma (internal resistance 47 Ohm/0.5 W) open contact max. 2 W C IP 65 (IEC 60529) protection against waterjets and dust Permanent mounted grey cable, 3 m long, 2 x 0.4 mm2 cross section sales@mvandc.com Phone: Fax:
21 System planning Plant design Layout of piping and meter installation The piping layout must ensure that the flowmeter is always full of liquid, and that no air or gas can enter. All consumers must be connected to the meter. All meters and modules should be easily accessible for reading. Do not install meters facing downwards. Straight piping for flow stabilization is not required. Meters with additional modules Install in the position shown in the module instructions. Meters without additional modules ARD rotary piston meters can be installed in horizontal, vertical or other positions. AMD and PMD vane wheel meters must always be installed horizontally. Selection of meters and auxiliaries Meters and auxiliaries must be chosen to cover all plant operating conditions:. Operating pressure and temperature according to type plate 2. Ambient temperature C 3. Material resistance: dependent on measuring medium and ambient conditions 4. Flow capacity Flowmeters must be dimensioned according to flow rate rather than pipe diameter. If necessary, change the calibre Shutoff valves Shutoff valves must be installed downstream of the flowmeter in order to prevent return flow and emptying. Return flow and emptying causes measurement errors and damages the flowmeter Dirt filter, Safety filter To prevent damage to the flowmeter, a dirt trap or prefilter should be installed upstream of the flowmeter. Max. prefilter mesh width: ARD rotary piston flowmeter: DN 5 mm 0. mm DN mm 0. mm DN mm 0. mm DN mm 0. mm DN 50 mm 0. mm AMD and PMD vane wheel flowmeters: Dirt traps are only necessary if the medium contains particles larger than 2 mm. Max. mesh width 0.8 mm.the filter in the meter intake is purely for safety reasons. It is too small to function as a dirt trap. sales@mvandc.com Phone: Fax:
22 Filling/batching systems For filling/batching systems the valve must be installed between the flowmeter and outlet. Short pipes between the flowmeter to the outlet give the greatest accuracy. To prevent water hammer, do not open or close valves too quickly. Water hammer will damage the flowmeter. Remote evaluation / auxiliary units In flowmeters with pulsers for remote display, return flow must be prevented. If the system layout does not ensure this, a nonreturn valve must be installed. Electrical cable layout Electrical cables and installations are subject to legal regulations which must be taken into account during system planning. All cabling must be installed by professional electricians. System layout must take account of:. Auxiliary equipment connections 3. Distributor boxes / cable ducts 2. Maximum cable lengths with/without amplifiers 4. Ambient interference factors Electrical installations in explosionrisk zones are subject to special regulations. Flowmeters in such zones must adhere to particular requirements. Consult a explosion risk expert. Remote pulse transmission AM 0662 AM0 66 Pulser power supply For remote evaluation of flowmeter readings, passive pulsers are available. The pulser must be powered from the connected unit. It generates one pulse per volumetric unit. Selection of correct pulser The correct pulser and best pulse value depends on the remote evaluation system. For remote totalization, large pulse values are generally selected (e.g. 0 litres / pulse). For instantaneous values, analogue signals and filling system control, small values should be selected. For batterypowered evaluation units, only reedtype pulsers can be used. Requirements of energizing units The pulse duration depends on the flow. At zero flow permanent contact may occur. The unit connected must therefore be designed for continuous loading. Otherwise protection e.g. by wiping relays must be provided. Correct pulse evaluation If flow is interrupted, fluid oscillation may occur in some systems (hydraulic vibrations at very low forward and reverse flows). In such cases pulses may be generated which are interpreted by the evaluation unit as forward flow. For instantaneous flow readings, these do not cause any interference because they can only occur when the flow is practically zero. If the pulser controls a numerical function, however, hydraulic vibrations must be prevented by suitable means. Pulse values and duration These depend on the type and nominal diameter of the flowmeter. Pulse values are indicated on the meter type plate. The pulse duration and the switchon and switchoff times are calculated with the following formulas: Switchon time Switchoff time = = = pulse value in l x 3600 flow rate Q in pulse period in s x switchon time in % 00 Switch ONtime Switch OFFtime Pulse period pulse period minus witchon time It is recommended to calculate these values for the smallest and largest flowrates expected in the system sales@mvandc.com Phone: Fax: AM 0668e Pulse period in s
23 Ordering information ARD sensors: Type designations and order numbers (for standard versions; special versions on request) ARD 000 measuring module Measuring Seal Rotary piston PN Tmax Type chamber bar C designation Brass housing with threaded connections Brass / PPS FPM Aluminium 6 30 ARD../A2 Hard rubber 6 50 ARD../H2 Graphite 6 30 ARD../G2 6 ARD../P2 Spherolitic cast iron housing with threaded connections Brass / PPS FPM Aluminium 6 30 ARD../2A2 Hard rubber 6 50 ARD../2H2 Graphite 6 30 ARD../2G2 6 ARD../2P2 Spherolitic cast iron housing with flanged connections Brass / PPS FPM Aluminium 30 ARD../22A2 Hard rubber 50 ARD../22H2 Graphite 30 ARD../22G2 Brass / PPS ) FPM Aluminium 30 ARD../228A2 Brass / FPM Aluminium 80 ARD../222A2 Graphite 80 ARD../222G2 ARD../222P2 Brass / ) FPM Aluminium 80 ARD../223A2 Nominal diameter Nominal diameter ) Measuring chamber, particularly for heavy fuel oil (measuring tolerance ± %) ARD 00 measuring module Measuring Seal Rotary piston PN Tmax Type chamber bar C designation Spherolitic cast iron housing with flanged connections Stainless FPM Aluminium 30 ARD../2224A2 steel / PPS Graphite 30 ARD../2224G2 Stainless steel 30 ARD../2224S2 ARD../2224P2 Stainless FPM Aluminium 80 ARD../22A2 steel / Graphite 80 ARD../22G2 Stainless steel 80 ARD../22S2 ARD../22P2 Stainless Graphite 80 ARD../22G6 steel / Stainless steel 80 ARD../22S6 ARD../22P ARD 3000 measuring module Measuring Seal Rotary piston PN Tmax Type Nominal diameter chamber bar C designation 5 Stainless steel (corrosion and acidproof) housing with flanged connections Stainless FPM Hard rubber 50 ARD../335H steel / Graphite 80 ARD../335G Stainless steel 80 ARD../335S ARD../335P Stainless Graphite 80 ARD../335G steel / Stainless steel 80 ARD../335S ARD../335P sales@mvandc.com Phone: Fax:
24 ARD 00 measuring module Measuring Seal Rotary piston PN Tmax chamber bar C plastic housing with flanged connections / Tantal FFKM 0 50 Type designation Nominal diameter 5 50 ARD../4467P Type designation key for device identification Example of type designation key Type series Nominal diameter ARD 5 mm mm mm mm 50 mm Configuration group /000 /00 /3000 /00 Housing Threaded Brass Spherolitic cast iron Flanged Spherolitic cast iron Stainless steel Measuring chamber Brass / PPS Brass / Brass / ( %) ) Stainless steel / PPS Stainless steel / / Tantal Brass / ( %) ) Rotary piston Aluminium Hard rubber Graphite Stainless steel Seal set FPM Fluoroelastomer FFKM Perfluoroelastomer Polytetrafluoroethylene Flange drillings DIN PN 0 / 6 / / ANSI 50 PSI 300 PSI 600 PSI JIS K5 K0 K6 K30 ARD / 22 3 /A 2 ARD A H G S P ) Measuring chamber, particularly for heavy fuel oil measuring tolerance ± % 24 / J6 sales@mvandc.com Phone: Fax: A50 A300 A600 J5 J0 J6 J30
25 ARD modules: Type designations and order numbers (for standard versions; special versions on request) Pulser module Pulse values in litres RW module 80 C Roller register RV Pulse values in litres Tmax C Type designation 80 RW/RD.. IN module 30 C IN 0.0/RW/RD IN 0./RW/RD.. 30 IN /RW/RD IN 0/RW/RD50 IN module 80 C IN 0.0H/RW/RD IN 0.H/RW/RD.. 80 IN H/RW/RD IN 0H/RW/RD50 INA module C Highresolution INA/RW/RD.. Highresolution Sealing plate INA/RD.. INA module 80 C Highresolution 80 INAH/RW/RD.. Highresolution Sealing plate 80 INAH/RD.. GTAS module for AS / ASP batching controls 80 C 80 GTAS/RD.. Nominal diameter Nominal diameter ATEXmodifications Modifications for ATEX devices Pulser module Roller register RV Tmax Type Pulse values in litres Pulse values in litres C designation RV module 80 C Not available with ATEX Certificate RV 0./RD5 80 RV /RD RV 0/RD RV 00/RD sales@mvandc.com Phone: Fax:
26 Type designation key for device identification Example of type designation key Pulser None IN Inductive IN H Pulse value in litres IN Inductive INA Inductive highresolution Module for AS / ASP filling control Roller register Roller register with integral pulser Sealing plate without roller register Nominal diameter of flowmeter Display units Tmax C / RV 0 / RD IN 0.0 IN 0. IN IN 0 IN 0.0H IN 0.H IN H IN 0H INA INAH GTAS RW RV 0. RV RV 0 RV DN 5 DN DN DN DN 50 Litres USGallons RD 5 RD RD RD RD 50 USG AMD measuring modules Housing AMD 3000 Stainless steel Measuring unit bearings PN bar Tmax C Type designation Nominal diameter Stainless steel / 6 Stainless steel / graphite 6 80 AMD../333 AMD../ Type designation key for device identification Example of type designation key Type series Nominal diameter Configuration group Housing Measuring unit Bearings Flange drillings AMD mm mm /3000 Stainless steel Stainless steel Graphite DIN ANSI JIS 26 AMD /3 3 3 /A50 AMD 3 PN 3 3 C 80 C PN 6 / 50 PSI 300 PSI 600 PSI K0 K6 K30 2 A50 A300 A600 J0 J6 J30 sales@mvandc.com Phone: Fax:
27 AMD modules: Type designations and order numbers (for standard versions) Pulser module Pulse values in litres RW module Roller register RV Pulse values in litres Tmax C Type designation Nominal diameter 80 RW/MD RV /MD IN 0./RW/MD.. IN /RW/MD.. IN 0.H/RW/MD.. IN H/RW/MD on request on request on request on request 80 INA/MD.. INAH/MD.. 85 on request 82 on request 80 GTAS/MD 84 8 RV module IN module INA module Highresolution Sealing plate Highresolution GTAS module for AS / ASP filling controls ATEXmodifications Modifications for ATEX devices Type designation key for device identification Example of type designation key Pulser None IN Inductive IN Pulse value in litres Tmax C INA Inductive highresolution Module for AS / ASP filling control Roller register Roller register with integral pulser Nominal diameter of flowmeter Display units 80 DN DN Litres / RW / MD IN 0. IN INA INAH GTAS RW RV MD MD sales@mvandc.com Phone: Fax:
28 Complete PMD flowmeters AM06689 Type designation PMD IN 0. PMD IN PMD INA PMD + adapter PMD IN 0. PMD IN PMD INA PMD + adapter PMD 32 IN 0. PMD 32 IN PMD 32 INA PMD 32 + adapter Version with inductive pulser IN 0. l with inductive pulser IN l with highresolution pulser prepared for batching control system with inductive pulser IN 0. l with inductive pulser IN l with highresolution pulser prepared for batching control system with inductive pulser IN 0. l with inductive pulser IN l with highresolution pulser prepared for batching control system Order No on request on request on request 837 PMD: for versions without pulser or with reedpulser type RH use type PMK (up to C) or PMW (up to C). ATEXmodifications Modifications for ATEX devices Accessories Type designation Remote totalizer Totalizer / Flowrate indicator Threaded connections Batching controls Batching controls Version Pulse counter, count step, with or without zeroing, ajustable F3 F6 (with differential and sum function) VSR /2 for DN 5 VSR 3/4 x /2 for DN VSR 3/4 for DN VSR for DN VSR /2 for DN AS manual controls ASP pneumatic controls F3 electronical F3 Exi (ATEX) Order No on request on request Accreditations Marking: II2G ct6 The ECTypeExamination Certificate is available on our website. Pressure Equipment Directive PED In accordance with guideline 97/23/EC, a CE or supplier conformity declaration are available on our website for all DOMINO devices. DISTRIBUTOR: Contact, Adress and Stamp HEAD OFFICE: ISTEC CORPORATION AQUAMETRO AG Ringstrasse 75 5 Park Lake Road, Sparta, NJ 0787 CH6 Therwil (Phone) Phone Fax (Fax) info@aquametro.com sales@isteccorp.com sales@mvandc.com Phone: Fax: Web: A Art Nr 45 With the exception of the RV... ancillary groups, all DOMINO components are certified according to ATEX Directive 94/9/EC. Änderungen vorbehalten / Sous réserve de modifications Modification rights reserved / Copyright Aquametro AG ATEX Directive
DOMINO Flow meters for chemical liquids DN
DOMINO Flow meters for chemical liquids DN 15...50 AM066168 AM066139 AM066169 Flow measurement of liquids in chemical, pharmaceutical, cosmetic and other industries. Batching and filling operations. VD
More informationVZO Pressure drop curves See Meter data. Option: Reed pulser or RV / IN pulser
VZO 15...50 Technical data 1) Volume display on roller counter, in litres fuel oil meter with threaded or flanged ends for horizontal, vertical or inclined mounting Option: Reed pulser or RV / IN pulser
More informationT O PA S Applications Features Your benefits
TOPAS Hot water Applications The TOPAS hot water meter is a velocity flowmeter based on the well-established multijet measuring principle. It operates over a wide measuring range and is used in all areas
More informationCONTOIL VZFA/VZOA , versions for higher requirements / applications
CONTOIL VZF/VZO 4...50, versions for higher requirements / applications For applications requiring an increased accuracy of ±0.5 % or better, such as: Measurement of L heating fuel or diesel in testing
More informationCONTOIL Fuel oil meters
CONTOIL Fuel oil meters Applications Flow measurement of mineral oils for heaters and fixed installations. VD 4-410 e 07.2012 Features Classical version with mechanical display State-of-the-art design
More informationVZFA/VZOA MISURATORI DI PORTATA FUEL OIL METERS. CONTOIL VZFA/VZOA , versions for special requirements / applications
VZFA/VZOA FUEL OIL METERS MISURATORI DI PORTATA CONTOIL VZFA/VZOA 5...50, versions for special requirements / applications For applications requiring an increased accuracy of ± % or better, such as: Versions
More information1/2-2 INSTALLATION INSTRUCTIONS
1/2-2 INSTALLATION INSTRUCTIONS ZE Table of contents General Meter Configuration 1 Application, planning and installation 1 Safety precautions 1 Plant design Layout of piping 2 -Meter installation 2 -Correct
More informationCONTOIL Fuel oil meters
CONTOIL Fuel oil meters Applications Flow measurement of mineral oils for heaters and fixed installations. VD 4-410 e 11.2012 Features Classical version with mechanical display State-of-the-art design
More informationVZ-01. Features. Oil Counter for Light to Heavy Fuel Oil. Description: Application: / Mounting on pressure or suction side
VZ-01 Oil Counter for Light to Heavy Fuel Oil Description: Features / Mounting on pressure or suction side The VZ-01 series of volume counters are rotary piston meters that function without auxiliary electrical
More informationCONTOIL Fuel oil meters
CONTOIL Fuel oil meters Applications Flow measurement of mineral oils such as heating or propellant fuels In burners, on board ships, land vehicles and fixed installations Marine and metrological type
More informationMake sure that no hazardous fumes can build up in the piping and in the meter during commissioning, decommissioning and dismantling.
The device and its accessories must only be used for their intended purpose and comply with safety regulations. Aquametro devices are manufactured according to valid standards and guidelines. Aquametro
More informationP17 Tempra Pro plugs, mobile sockets, fixed sockets, surface mounting sockets and appliance inlets - IP 66/67-63 A A
CONTENTS Page 5 555 09 5 555 29 5 555 59 5 555 9 1. General characteristics...1 2. Use...1 3. Range/Equivalence table...2 4. Dimensions..............................3 5. Technical characteristics...5 6.
More informationTOPAS PMW-basic. Customer benefits. Product features
TOPAS PMW-basic The TOPAS PMW-basic product line covers a wide range of applications in hot water measurement. This innovative system offers all types of water measurement right up to data integration
More informationProFlow TO BE REALLY SURE. Vane Meters. Experience in flow measurement. Introduction
ProFlow N142 P R O D U C T B U L L E T I N Vane Meters Special versions This brochure comprises only VAF Instruments standard delivery program. Special flowmeter variants can be offered as tailor-made
More informationMetal tube variable area flowmeter for gases, liquids and steam
Metal tube variable area flowmeter for gases, liquids and steam Metallic or plastic tube with a robust construction Indication by means of magnetic coupling Scales calibrated in l/h, m 3 /h, kg/h, t/h,
More informationPump Kits. More than just pumps
Pump Kits More than just pumps Table of Contents FLUX Pump Kits for: Acids and Alkalis 4 5 Concentrated Acids and AdBlue 6 Petroleum Products 7 Flammable Liquids 8 Universal Applications 9 99.98 % Drum
More informationPump kits. We deliver values.
Pump kits We deliver values. Table of contents FLUX Pump Kits for: Acids and alkalis 4 5 Concentrated acids and AdBlue 6 Petroleum products 7 Flammable liquids 8 Universal applications 9 99,98 % barrel
More informationa q u a c o n c e p t Applications Features Benefits
aquaconcept Cold water Swiss Made Applications The unique aquaconcept modular design covers a wide range of water applications. This innovative system offers all types of water measurement right up to
More informationPOSITIVE DISPLACEMENT FLOW METERS
POSITIVE DISPLACEMENT FLOW METERS ABOUT MACNAUGHT Macnaught Pty Ltd is a privately owned manufacturing company based in Australia, established in 1948. Macnaught s experience in Positive Displacement Flow
More informationPOSITIVE DISPLACEMENT FLOW METERS
POSITIVE DISPLACEMENT FLOW METERS ABOUT MACNAUGHT Macnaught Pty Ltd is a privately owned manufacturing company based in Australia, established in 1948. Macnaught s experience in Positive Displacement Flow
More informationBe prepared with Lutz. Safety is our concern
Be prepared with Lutz Safety is our concern L u t z P u m p S e t s L u t z P u m p S e t s Lutz Pump Sets A quick solution for many applications 2 Already pre-assembled Example: Pump set consisting of:
More informationEZ-View. Flow Meters ISO CERTIFIED 9001
EZ-View ISO CERTIFIED 9001 General Design Features OPERATING PRINCIPLE The EZ-View Flow Meter is a variable-area instrument. A precisionmolded, sharp-edged Orifice, located within the Piston Assembly,
More informationSelection of DODGE E-Z KLEEN Polymer and Stainless Steel Housed Ball Bearings. P = (X x F R ) + (Y x F A ) F A C o
Selection of DODGE and Stainless Steel Housed Ball Bearings DODGE ball bearings are primarily designed for radial loading. However, they have the capacity to carry thrust loads and combined radial/thrust
More informationVolumeter. RMG Meßtechnik GmbH. Publication No E
Volumeter TRZ 03-K RMG Meßtechnik GmbH Publication No. 3.171-E P.O.Box 80 D-3550 Butzbach (Germany) Phone: +49 (0)6033 897-0 Fax: +49 (0)6033 897-130 E-mail: messtechnik@rmg.de Web site: http://www.rmg.de
More informationDomestic Water Meter. Elin Wasserwerkstechnik. Contact Water Meter MTM for cold water. Features
Domestic Water Meter Elin Wasserwerkstechnik Contact Water Meter MTM for cold water Features Nominal diameter DN15 to DN50 Cold water up to 30 C (safe up to 50 C) Operating pressure up to 16 bar Control
More informationSTEEMCO Flowmeter for Steam
STEEMCO Flowmeter for Steam Typical Applications The STEEMCO flow meters measure the flow of saturated and superheated steam within the process industries, including chemical, petro-chemical, pharmaceutical
More informationRMG Meßtechnik GmbH. Publication No E
Turbine meter TRZ 03 RMG Meßtechnik GmbH Publication No. 3.161-E P.O.Box 80 D-3550 Butzbach (Germany) Phone: +49 (0)6033 897-0 Fax: +49 (0)6033 897-130 E-mail: messtechnik@rmg.de Web site: http://www.rmg.de
More informationMetal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam
Metal tube flowmeters Variable area flowmeter for liquids, gases and steam Metallic or plastic tube with a robust construction Indication by means of magnetic coupling Scales calibrated in l/h, m 3 /h,
More informationVZD / VZP and DFM Consumption measurement
CONTOIL VZD / VZP and DFM Consumption measurement Applications Fuel consumption measurement for trucks, buses, trains, construction and agricultural machinery, small boats and generators. Features Quick
More informationDesign and application
Design and application The function of the SGM is based on the variable area float principle. In all cases where a dependable device is required for indicating instantaneous values and monitoring the flow
More informationVolumeter TRZ 03-K PRODUCT INFORMATION. Reliable Measurements of Gas
Volumeter TRZ 0-K PRODUCT INFORMATION Reliable Measurements of Gas Method of operation, Construction Method of operation The TRZ 0-K Volumeter is a flow meter suitable for metering gases, where the rate
More informationINSTALLATION INSTRUCTION & TECHNICAL MANUAL FLOWMETER
Sep 2003 INSTALLATION INSTRUCTION & SERIES: MICA (FL & RC) INSTALLATION INSTRUCTION & Type: MICA Series: MICA Page: INSTALLATION CONCEPT... 2 2 MOUNTING POSITION OF THE METER... 2 2. General remarks...
More informationMagnetic-inductive flow meter for hazardous areas
Magnetic-inductive flow meter for hazardous areas Technical Datasheet EPX / UMF3 high accuracy: 0.3 % of actual maintenance-free no pressure drop numerous lining materials numerous electrode materials
More informationVD e CONTOIL. MDO and HFO applications
VD 7-100 e 07.2009 CONTOIL MDO and HFO applications Table of contents 1 Introduction 3 1.1 Liability Disclaimer 3 1.2 Safety precautions 3 1.3 Conventions 4 1.4 Supplementary Instructions 4 2 Technical
More informationFlap-Type Flow Meter Prall
Suitable for H 2 O, acids, alkaline solutions and gases Spring-loaded flap Horizontal or vertical direction of flow Largely independent of viscosity Limit contacts, optional Analog output 4 20 ma, optional
More informationP17 combined units LIMOGES Cedex Telephone : Fax : Cat. No.(s) : 566 XX XX XX XX
8704 LIMOGES Cedex Telephone : + 33 0 06 87 87 - Fax : + 33 0 06 88 88 P17 combined units Cat. No.(s) : 66 XX - 72 XX - 77 XX - 89 XX CONTENTS Page 1. Description...1 2. Use...1 3. Range.......................
More informationJUMO dtrans p20 DELTA
Data Sheet 403022 Page 1/9 JUMO dtrans p20 DELTA Differential pressure transmitter Brief description The JUMO dtrans p20 DELTA differential pressure transmitter with HART interface combines maximum precision
More informationWESAN WP WOLTMAN METER
WESAN WP WOLTMAN METER APPLICATION The bulk water meter WESAN WP can be used for measuring volumes of cold water (up to 50 C) in supply lines with high flow at low pressure loss. The measuring chamber
More informationAPOVAC R Vacuum Systems
APVAC R Vacuum Systems with closed ring-liquid loop for the suction and recovery of gases and vapours APVAC = Anti Pllution VACuum PED APVAC R APVAC Vacuum systems with closed ring-liquid loop for the
More informationPETROL. Double Case PD Flowmeters. Trust in us Our Quality Counts. Technical Bulletin. PETROL Instruments S.r.l.
Double Case PD Flowmeters Technical Bulletin The trusted specialist manufacturer of high precision instruments that relies upon the accurate measurement of fluid volumes Trust in us Our Quality Counts
More informationTurbine flowmeters Series TM
Turbine flowmeters Series TM Suitable for liquids Possibility of installation in all flow directions Special design for high pressure available Excellent relationship flow range / flowmeter size Low pressure
More informationVersaFlow Vortex 100 Vortex Flow Meter Specifications
VersaFlow Vortex 100 Vortex Flow Meter Specifications 34-VF-03-05 May 2011 The All-In-One Solution The VERSAFLOW is the only vortex flowmeter with integrated and temperature compensation in 2- wire technology.
More informationCOVOL. Operating Data. Areas of Application. Measuring Ranges. Method of Operation. Fields of operation. Features. Installation information
Durchflussmessung Flowmeters COVOL Areas of Application Operating Data Method of Operation Oscillating Piston Operating pressure, max. PN 10 (Plastic) PN 16 (Stainless Steel) Fields of operation Consumption
More informationOPTIFLUX 6000 Technical Datasheet
OPTIFLUX 6000 Technical Datasheet Electromagnetic flow sensor for hygienic and sanitary applications Robust stainless steel housing for hygienic and aseptic operation Fully suitable for CIP and SIP Typical
More informationOptions guide. Electromagnetic flowmeters. M9xx
Options guide Electromagnetic flowmeters M9xx Ordering codes Model Description M 910 -V0 0 0 0 DN50 PN16 Example Sensor M Basic Ex Ex certified (remote version only) Transmitter 910E Economic version 910
More informationMidFlow _ 135. Sliding Vane Meters DN (1-2 ) Model PT / Fuel Oil Flowmeters135. Product Bulletin
MidFlow Model PT / Fuel Oil Flowmeters135 Sliding Vane Meters DN 25-50 (1-2 ) _ 135 Product Bulletin WWW.VAF.NL 1 Introduction VAF Instruments MidFlow Model PT positive displacement sliding vane type liquid
More informationSTEEMCO-MAS Flowmeter for Steam
STEEMCO-MAS Flowmeter for Steam Typical Applications The STEEMCO-MAS flow meters measure the mass flow of superheated steam within the process industries, including chemical, petro-chemical, pharmaceutical
More informationQuantometer MZ. Description
Quantometer MZ < High accuracy budget meter < Flow rate up to 10000 m 3 /h < Pressure range up to 100 bar < Equipped as standard with the cyble target. < Various options available: Low and high frequency
More informationNon-return Valve BOA-R. PN 6/16 DN Flanged. Type Series Booklet
Non-return Valve BOA-R PN 6/16 DN 15-350 Flanged Type Series Booklet Legal information/copyright Type Series Booklet BOA-R KSB Aktiengesellschaft Pegnitz All rights reserved. Contents provided herein must
More informationPhysical properties of PET resins. 1. Intrinsic Viscosity (IV)
Physical properties of PET resins 1. Intrinsic Viscosity (IV) Intrinsic viscosity (IV) is a measure of polymer molecular weight, which in turn is a measure of the mechanical strength capability of the
More informationEZ-View Flow Meters. General Design Features OPERATING PRINCIPLE
General Design Features 9 8 5 6 7 4 3 2 1 10 OPERATING PRINCIPLE The EZ-View Flow Meter is a variable area instrument. A precisionmolded, sharp-edged Orifice 1, located within the Piston Assembly, 2 forms
More informationMX-SERIES OVAL GEAR FLOW METERS
Data Sheet MX-SERIES OVAL GEAR FLOW METERS Supplied by.com Call us on +44 (0)118 916 9420 Email info@247able.com MX-Series Oval Gear Flow Meters Features and Advantages P From ¼ DN8 at 0.5LPH to 4 DN100
More informationSmall on price, big on boot
018 VOLUME 1 FEATURES KEY Toe Cap High Heat Non Conductive Female Male Leather Chemical Body International Organization for Standardisation Body PU - Polyurethane RECOMMENDED INDUSTRY USE* General Smelting/
More informationStrainer BOA-S PN 6/16/25 DN Type Series Booklet
Strainer PN 6/16/25 DN 15-400 Type Series Booklet Legal information/copyright Type Series Booklet All rights reserved. The contents provided herein must neither be distributed, copied, reproduced, edited
More informationORIMAS Mass Flowmeter
Typical Applications ORIMAS Mass Flowmeter The ORIMAS mass flow meters measure the mass flow of most liquids and gases within the process industries, including chemical, petro-chemical, pharmaceutical
More informationBackflushing Filter AutoFilt RF3
Backflushing Filter AutoFilt C 2,5 4 6 8 1. TECHNICAL SPECIFICATIONS 1.1 GENERAL The automatic back-flushing filter AutoFilt is a self-cleaning system for extracting particles from lowviscosity fluids.
More informationOscillating piston flowmeters Series COVOL Positive displacement flowmeter for liquids
Oscillating piston flowmeters Series COVOL Positive displacement flowmeter for liquids Suitable for all kind of liquids Viscosity up to 120000 mpa s Excellent performance with changing process conditions
More informationAutomated Globe Valves. BOA-H Mat P PN 16/25 DN Type Series Booklet
Automated Globe Valves BOA-H Mat P PN 16/25 DN 20-150 Type Series Booklet Legal information/copyright Type Series Booklet BOA-H Mat P All rights reserved. The contents provided herein must neither be distributed,
More informationSITRANS F flowmeters. SITRANS F R Meters for lubricating oils (distribution of mineral oils) 4/350 Siemens FI Overview
(distribution of mineral oils) Type For custody transfer use Not for custody transfer use Flow rate in l/min (USgpm) Flow rate in l/min (USgpm) Minimum Maximum Minimum Maximum Pistol-grip meter Without
More informationMagnetic-inductive flow meter EPS / UMF2. Technical data sheet
Magnetic-inductive flow meter EPS / UMF2 Technical data sheet high accuracy: 0.3 % of actual maintenance-free no pressure drop numerous lining materials numerous electrode materials low-cost grounding
More informationJUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram
Data Sheet 403025 Page 1/10 JUMO dtrans p20 Process pressure transmitter Brief description The JUMO dtrans p20 pressure transmitter with HART interface combines maximum precision with easy operation. It
More informationEccentric. P l u g V a l v e. Versatile PIPE CONNECTIONS, REPAIR & FLOW CONTROL PRODUCTS FOR THE UTILITIES INDUSTRY
Versatile Eccentric P l u g V a l v e Flow Control & Isolation Solved PIPE CONNECTIONS, REPAIR & FLOW CONTROL PRODUCTS FOR THE UTILITIES INDUSTRY Eccentric Plug Valve - Series 601 Overview Flow control
More informationSuperstatic 440. Static Heat Meter, Static Cooling Meter. Application
Superstatic 440 Static Heat Meter, Static Cooling Meter Application Design The Superstatic 440 is a static heat or cooling meter according to standard EN1434 class 2 based on the fluid oscillation principle,
More informationQUALITY INDUSTRIAL FLOWMETERS
QUALITY INDUSTRIAL FLOWMETERS COMPANY PROFILE Trimec Industries is an Australian owned ISO9001:2008 quality certified company specializing in the design and manufacture of a proprietary range of positive
More informationStrength, resilience, rigidity - these are all attributes needed to combat arduous and aggressive conditions. Tufflite has them all.
Strength, resilience, rigidity - these are all attributes needed to combat arduous and aggressive conditions. Tufflite has them all. From commercial applications requiring a simple sealed luminaire, right
More informationaquaconcept Product features Customer benefits
aquaconcept The unique aquaconcept modular design covers a wide range of water applications. This innovative system offers all types of water measurement right up to data integration into your specific
More informationInformation. Mechanical. Electrical. Chemical. Conversions & Calculations
i Information Installation Monitoring Repair As part of our fluidity.nonstop concept, AxFlow has become one of the leading UK providers of pump care services. We have Pump Service Centres spread across
More informationOPTIMASS 3000 Technical Datasheet
OPTIMASS 3000 Technical Datasheet Sensor for mass flow First choice for low flow applications Certified secondary pressure containment A common footprint for all three sizes, in Hastelloy or Stainless
More informationSITRANS F flowmeters. SITRANS F R Drum meters Overview 4/355. Overview
SITRNS F R Drum meters Overview Drum meter Drum meter for industrial liquids For quantity measurements of: enzene in gas works and iron and steel works Solvents and other liquids during operational and
More informationPressure switch FF 4 Approval acc. to ATEX EN For mining and chemistry
Approval acc. to ATEX EN 679 Description n... 3 bar with perbunan diaphragm. n 6... 5 bar with plastic plunger and throttle. n Throttle must be removed when using viscous media. 151 mm 7 13 mm a 1 mm,5
More informationSystem 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter
System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter Application Used to convert a direct-current input signal into a pneumatic output signal for measuring and control
More informationMetallic Systems TYPE SPTC
CONDUIT 27/01/2009 Technical Data Sheet Page No. 1 Applications Hospitals External Safety Critical Area Fittings IP54 SPB Fittings type A & B Characteristics Very High UV Resistance High Flexibility Medium
More informationViscoSense 3D. Viscosity & Density Measurement Enabling Mass Flow Measurement. Product Bulletin TO BE REALLY 1 SURE
ViscoSense 3D Viscosity & Density Measurement Enabling Mass Flow Measurement 774 Product Bulletin WWW.VAF.NL TO BE REALLY 1 SURE 1 Introduction Principle of operation Most of the operating costs of a ship
More informationDifferential Pressure Gauges Cryo Gauge Model , Cu-alloy Model , Stainless Steel Series
Differential Pressure Gauges Cryo Gauge Model 712.15.160, Cu-alloy Model 732.15.160, Stainless Steel Series Mechanical Pressure Measurement WIKA Data Sheet PM 07.30 Applications Level measurement in closed
More informationTemperature sensors. and accessories for heat and cooling measurement points. Applications. Benefits. Features
Temperature sensors and accessories for heat and cooling measurement points Applications Temperature sensors are metrological components for heat or cold measuring points. They are used in pairs and measure
More informationIssue One. Chemical Compatibility Guide
Issue One Chemical Compatibility Guide Chemical Compatibility Guide Fluolion 200, 700, 800, 900 modified PTFE sheet gasket materials The following information is issued as a guide only. All media are taken
More informationDiaphragm valve MV 309
Diaphragm valve MV 309 Nominal size DN 15 32 Nominal size 1/2 1 1/4 Pressure PN 6 bar Features pneumatic diaphragm valve DN 15 32 compact piston drive for medium pressure up to 6 bar (PTFE diaphragms)
More informationOrifice plate flowmeters Series PR By-pass flowmeter for liquids, gases and steam
Orifice plate flowmeters Series PR By-pass flowmeter for liquids, gases and steam By-pass flowmeter with orifice plate (compact system PRC and separate system PR) for big flow ranges Flow indication by
More informationINLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1
INLINE Flow sensor for hazardous area II G/D - II D - II GD - I M Type SE0 Ex can be combined with... Flow meter with NAMUR or NPN/PNP output signal Mounting, dismounting of electronics by a Quarter-Turn
More informationHigh Precision Turbine Wheel Flow Meter for Liquids
High Precision Turbine Wheel Flow Meter for Liquids measuring monitoring analysing Measuring ranges: 0.006-0.1 to 10-500 L/min water Measuring accuracy: ± 1.25% f. s. pmax: 345 bar; tmax: 135 C Viscosity
More informationLBTC Series Positive Displacement Rotary Vane Flow Meters
LBTC Series Positive Displacement Rotary Vane Flow Meters Summary LBTC Series positive displacement rotary vane flow meters are independently designed and manufactured by our company on the base of absorbing
More informationApplication The DA03 serves as indicator of differential. Follow mounting instructions in accordance to application.
DA03 Differential Pressure Gauge / Differential Pressure Gauge and Switch Models for Assignment in Explosion-hazardous Areas per Directive 94/9/EC (ATEX) Application The DA03 serves as indicator of differential
More informationOperating Instructions. Pneumatic Control Valve Low Temperature. Type Series GS3
Operating Instructions Pneumatic Control Valve Low Temperature Type 8026 Series GS3 With: Digital Positioner Type 8048 Electro-pneumatic Positioner Type 8047 Pneumatic Positioner Type 8047 Version: 03/2006
More informationDifferential pressure gauge Model , copper alloy Model , stainless steel version
Mechanical pressure measurement Differential pressure gauge Model 712.15.100, copper alloy Model 732.15.100, stainless steel version WIKA data sheet PM 07.29 Applications for further approvals see page
More informationSuperstatic 440. Static Heat- and Cooling Meter. Application
Superstatic 440 Static Heat- and Cooling Meter Application Design The Superstatic 440 is a static heat- and cooling meter according to standard EN1434 class 2 based on the fluid oscillation principle,
More informationElectropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN
Electropneumatic Converters i/p Converters Type 6111 Fig. 1 Type 6111 in standard version Fig. Type 6111 mounted on a supply air manifold Fig. 3 Type 6111 in field enclosure Mounting and Operating Instructions
More informationHigh pressure industrial ball valves
High pressure industrial ball valves High pressure industrial ball valves Applications Legris high pressure ball valves are suited for a wide range of industrial applications. They are designed both for
More informationLevel switches Series LC40 Float level switch for liquids
Level switches Series LC40 Float level switch for liquids Simple and robust construction Versatile and easily adaptable to the different control positions of the industrial processes Side or top of the
More informationMagnetic float switch For vertical installation Model FLS (models with Ex approval: 60, AL-ADF)
Level measurement Magnetic float switch For vertical installation Model FLS (models with Ex approval: 60, AL-ADF) TC Fluid Control WIKA data sheet LM LM 3001 30.01 for further approvals see page 3 Applications
More informationMetal tube flowmeters Series M21 Variable area flowmeter for low flows of liquids, gases and steam
Metal tube flowmeters Series M21 Variable area flowmeter for low flows of liquids, gases and steam Metallic tube with a robust construction Indication by means of magnetic coupling Scales calibrated in
More informationtekson TS Series Low Cost Ultrasonic Water Energy Flow Measurement
Sensing the pulse of industry tekson TS Series Low Cost Ultrasonic Water Energy Flow Measurement tekflo sensors are proud to present their tekson TS Series ultrasonic water energy meter, which uniquely
More informationDifferential Pressure and Flow meters Accessories for the Media Series
Differential Pressure and Flow meters Accessories for the Media Series 7 8 9 10 11 6 12 Media 5 Media 6 Media 05 1 5 2 4 Media 4 3 Selection and application These accessories upgrade the devices of the
More informationFlow switches Series AD/VH
Flow switches Series AD/VH Flow switch and indicator for liquids and gases Suitable for clear, opaque or turbid liquids (series AD & VH), and for gases (series AD) Flow switching by means of magnetic coupling,
More informationHYPRA Prisinter 16/32/63 A
8704 LIMOGES Cedex Telephone: + 33 0 06 87 87 - Fax: + 33 0 06 88 88 HYPR Prisinter 16/32/63 Page 1. General characteristics........1 2. Range......................1 3. Dimensions............... 2-3 4.
More informationBGN. All Metal Variable Area Flow Meter. Technical Data Sheet
All Metal Variable Area Flow Meter BGN Technical Data Sheet Extremely robust through star guiding system instead of guiding rod Flow metering of liquids, gases and steam Available up to nominal size of
More informationFiltration efficiency: 99% or more HEPO2element
High Precision Filter for Liquids Series Filtration efficiency: 99% or more HEPO2element Filtration accuracy: 2, 4, 6 or 13 µm (Filtration efficiency 99%) Membrane element Filtration accuracy: 0.2 or 0.4
More informationDMP 331P DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm
DMP P Industrial Pressure Transmitter Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Industrial
More informationProduct Information S/PA
Description Tico S is a high performance machinery mounting material. It matches today s fast changing manufacturing environment, where ease of machine mounting and flexibility of plant layout are prime
More informationThe EPSILON is based on the principle of measuring velocity in the pipe line, therefore the flow measurement is volumetric.
Typical Applications EPSILON Flowmeter The EPSILON flow meters measure the flow of most liquids and gases within the process industries, including chemical, petro-chemical, pharmaceutical and the power
More informationBFS-10-O G1/4: BFS-10-O G1/2: BFS-10-O G1: Contact rating: BFS-10-O G1/4
Flow Switches Index: B / 923-1838 BFS-10-N / BFS-10-O for monitoring liquids, with or without optical display Features set point continuously adjustable rugged, low hysteresis, any mounting position, high
More information