SITRANS F flowmeters. SITRANS F R Drum meters Overview 4/355. Overview
|
|
- Randell Short
- 6 years ago
- Views:
Transcription
1 SITRNS F R Drum meters Overview Drum meter Drum meter for industrial liquids For quantity measurements of: enzene in gas works and iron and steel works Solvents and other liquids during operational and production checks Condensation in district heating works For measuring components used for mixing in the chemical industry and the synthetic fibers industry lcohol measuring equipment Standard sampler pplication: For quantity measurement of spirits For determination of the alcohol content of spirit for taxing purposes in distilleries, alcohol and liquor factories. The devices satisfy the German monopoly administration. ccessories: Leakage indicator Sampling cock SITRNS ethyl alcohol meters pplication For quantity measurement of spirits and simultaneous determination of the amount of ethyl alcohol, taking into account the temperature and density For taxing purposes in distilleries, alcohol and liquor factories The devices satisfy the German monopoly administration. Siemens FI /355
2 SITRNS F R Drum meters Overview pplication Drum meters for industrial liquids, alcohol and ethyl alcohol are quantity meters primarily characterized by their high measuring accuracy even at very low flow rates (drops) and their use at low pressures. Function Overview of how drum meters work Drum meters/standard sampler Drum meters are purely mechanical devices where the liquid to be measured drives the mechanism. It must be ensured that there is no counter-pressure on the outlet, i.e. a backpressure of the liquid must not occur in the meter. The measuring unit, the rotating drum, is divided into three chambers. Filling-up of the bottom chamber and overflowing of the liquid into the next chamber displaces the center of gravity of the filling and a turning movement results. The drum is rotated by one third of its circumference, i.e. the next chamber is swung down and then filled whilst the previous chamber is emptied through the outlet. The number of times the drum is moved round is transmitted from the axis of the drum to a single-pointer dial with a 5-digit non-resettable drum-type counter via a magnetic coupling. The quantity determined from the number of drum rotations is directly displayed in liters. SITRNS ethyl alcohol meters The ethyl alcohol meters work by the same principle as the drum meters. In other words, the total quantity of spirits flowing through the drum is measured. Since the quantity of pure alcohol (ethyl alcohol) present in the spirits must be known for taxing purposes, the spirits are passed prior to the quantity measurement through a test setup consisting of temperature measuring equipment with a Pt1000 sensor and equipment for measuring the density. Pulses proportional to the quantity are output by means of a double pulser coupled to the drum. The input signals for quantity, temperature and density are compared in a computer with the defined values of the OIML alcohol table. Following displays are output on two non-resettable electromechanical pulse counters in the computer: Quantitiy of mixed alcohol/water in liters Quantity of alcohol in liters The density and temperature of the liquid can be read continuously on a further display. Connections are available for a printer, a remote indicator and an RS 232 interface. /356 Siemens FI
3 SITRNS F R Drum meter for industrial liquids Drum meter for industrial liquids The drum meter is used for measuring enzene in gas works and iron and steel works Solvents and other liquids during operational and production checks Condensation in district heating works The drum meter can also be used for measuring components used for mixing in the chemical industry and the synthetic fibers industry. Drum meter 7 M S For industrial liquids Meter size 3 l (0.8 USg) 1 6 l (1.6 USg) 2 15 l (.0 USg) 3 Preliminary custody transfer test 1) With Inductive pulser With 1 channel With 2 channels C Retrofitting kits for conversion of pendulum type figure-rollers into single-pointer dials Comprising adapter, intermediate gear and dial For meter size 3 l (0.8 USg) 7MS l (1.6 USg) 7MS l (.0 USg) 7MS900-1C00 1) With water only ccessories Instruction Manual German/English Dimensional drawings C The two-part housing is made of cast iron and pressure-tight up to max. 0. bar. On the bottom part are inlet and outlet connections. The pipe connections are designed as oval flanges with female thread. The housing also available with lining and lid. The drum is made of welded chromium-nickel steel sheet. Values are indicated (in liters) by a single-pointer dial with a nonresettable 5-digit drum type counter. Individual quantities are determined from the difference between the two values on the non-resettable drum-type counter or on the resettable pulse counter in the case of a remote display. Technical specifications Meter size (drum capacity) Required inlet height (IH) Max. flow rate q max 1) Liters (USg) mm (inch) l/h (USgpm) 3 (0.8) 200 (7.87) 800 (3.5) 6 (1.6) 250 (9.8) 1500 (6.6) 15 (.0) 300 (11.8) 000 (17.6) Error limits with a flow rate range of q min : q max = 1 : % of the correct value q min : q max = 1 : % of the correct value Permissible liquid temperature Max. 95 C (203 F) Permissible viscosity of liquid Max. 2 mpa s Pipe connections Meter size Inlet Outlet 3 liters (0.8 USg) G ¾ G1¼ 6 liters (1.6 USg) G1¼ G1½ 15 liters (.0 USg) G2 G2½ Oval flanges to DIN 2558, drilled Certificate and approvals The meter is not subject to the pressure equipment directive (DGRL 97/23/EC). 1) The values quoted here for q max apply only for liquids with a density ρ 1 and a dynamic viscosity 2mPa s. With ρ < 1, a max. flow rate of ρ q max is permitted. Drum meter for industrial liquids, dimensions in mm (inch) c 1 Without pulser c 2 With pulser IH With an inlet open the atmospheric pressure, IH is the minimum height at which the inlet line must lie above the inlet connection in order for the maximum flow through the drum meter to be reached.. 1 Screw plug G½ x 10 DIN 910 (only available for pressure-tight designs) 2 Mating flanges (included in delivery) Meter a b c1 c2 Ø d e size l (USg) mm (inch) 3 (0.8) (9.) (1.8) (16.5) (1.5) (17.7) (0.5) 6 (1.6) 386 (15.2) 18 (16.5) 517 (20.) 599 (23.6) 11.5 (0.5) 350 (13.8) 15 (.0) 585 (23.0) 620 (2.) 561 (22.1) 63 (25.3) 15 (0.59) 31 (17.0) Meter f g h i k IH size l (USg) mm (inch) 3 (0.8) (.9) 220 (8.7) 155 (6.1) 200 (7.9) (11.8) (13.0) 6 (1.6) 300 (11.8) 330 (13.0) 212 (8.) 228 (9.0) 163 (6.) 250 (9.8) 15 (.0) 90 (19.3) 530 (20.9) 20 (9.5) 30 (13.) 265 (10.) 300 (11.8) Siemens FI /357
4 SITRNS F R Drum meter for alcohol, standard sampler Drum meter for alcohol, standard sampler Drum meter, open and without lid The drum meter is used for quantity measurement of spirits and determination of the content of alcohol in spirits for taxing purposes in distilleries, alcohol and liquor factories. The drum meter satisfies the regulations of the German monopoly administration. The device is comprised of a housing and the actual drum meter. administration 1) The two-part, cast iron housing is made of up of a bottom part and a lid. On the bottom part are inlet and outlet connections. With 2) The pipe connections are oval flanges to DIN 2558, drilled. The drum is made of welded CrNiMo steel sheet and has 1 to 3 sample scoops of approx. cm³ contents each (according to 2) For Germany only German monopoly administration). Values are indicated (in liters) by a single-pointer dial with a nonresettable 5-digit drum type counter. Instruction Manual ccessories There is also an assembly to indicate overloaded operation. German/English The instrument housing is made of aluminum sheet finished with alcohol-resistant paint and can be sealed (according to German Dimensional drawings monopoly administration). The sample collection vessel is accommodated in the housing 630 (2.82) 315 (cabinet). The sample collection vessel is made of CrNiMo sheet 315 (12.1) (12.1) steel, has an inlet and an outlet cock at the bottom and can be sealed. Technical specifications Error limits, permissible liquid temperature Required inlet height (ZH) Meter size 3 liters (0.8 USg) 6 liters (1.6 USg) 15 liters (.0 USg) Certificate and approvals In accordance with the regulations of the German monopoly administration bove the inlet connection Inlet 200 mm (7.9 inch) 250 mm (9.8 inch) 350 mm (13.8 inch) The meters are not subject to the pressure equipment directive (DGRL 97/23/EC). Drum meter for alcohol, Standard sampler 7 M S Meter size 3 l (0.8 USg) 1 6 l (1.6 USg) 2 15 l (.0 USg) 3 Certificate from German monopoly 1) uthorization from the German monopoly administration must be obtained prior to ordering the instrument and enclosed with the order. 150 (60.63) 900 (35.6) 60 (25.21) 70 (2.76) 150 (5.91) 10 (5.51) 30 (13.39) 120 (.72) Drum meter for alcohol, standard sampler, dimensions in mm (inch) 1168 (6.01) 265 (10.3) C (29.35) 570 (22.6) 225 (8.86) 225 (8.86) 100 (3.9) /358 Siemens FI
5 SITRNS F R SITRNS, ethyl alcohol meter without housing lcohol measuring equipment (ME), ethyl alcohol meter The ethyl alcohol meters are used for quantity measurement of spirits and simultaneous determination of the amount of alcohol (amount of ethyl alcohol), taking into account the temperature and density; for taxing purposes in distilleries, alcohol and liquor factories. The ethyl alcohol meters satisfy the regulations of the German monopoly administration. Ethyl alcohol meter without housing Housing made of cast iron, two part. The housing is pressuretight up to 0. bar (5.8 psi). - ottom part with inlet and outlet connections - Pipe connection: Oval flange with female thread -Lid Drum made of CrNiMo sheet steel (welded); capacity: 15 l ( USg) Display/signal output - Single-pointer dial with non-resettable, 5-digit drum-type counter - Double inductive pulser, both linked to the drum through a magnetic coupling and adjustable intermediate gear - Sample passed into drum through temperature sensor (Pt1000) and density measuring unit - Display of actual quantity of spirits, actual quantity of alcohol or alcohol/water value The ethyl alcohol meter has a central computer for processing density and temperature signals and volume-proportional pulses, which are compared with the entered values of the OIMC alcohol table. Example of measuring arrangement Technical specifications Error limits: llow. metering mat. temp. Dimensional drawings In accordance with the regulations of the German monopoly administration Certificate and approvals The meter is not subject to the press. equip. directive (DGRL 97/23/EC). lcohol measuring equipment 7 M S Consisting of ethyl alcohol meter, density measuring equipment, central computer and power pack; drum capacity 15 l (.0 USg) Certificate from German monopoly administration 1) With 2) Uninterruptible power supply and back-up battery With V.2 interface (RS 232) 0 With 1 Printer 0 With 1 1) uthorization from the German monopoly administration must be obtained prior to ordering the instrument and enclosed with the order. 2) For Germany only ccessories Instruction Manual German English 860 (33.88) 978 (38.53) 6Z5600-0CC Z5600-0CC (33.02) 752 (29.33) SITRNS, ethyl alcohol meter, dimensions in mm (inch) 870 (3.28) 37 (1.6) 20 (0.79) Siemens FI /359
6 SITRNS F R Sample cock Sampling cock 7 M S Sampled quantity 20 cm³ (1.22 cu.in) Certificate from German monopoly administration 1) With 1) uthorization from the German monopoly administration must be obtained prior to ordering the instrument and enclosed with the order. Dimensional drawings Sample cock The sample cock is used to take samples from pipelines for monitoring operation, with simultaneous metering of the sampled quantities for taxing purposes. The sample cock is approved for tax monitoring in Germany. 10 (0.39) 35 (1.38) 20 (0.79) 75 (2.95) 150 (5.91) 10 (0.39) 39 (1.5) 50 (1.97) 120 (.72) 150 (5.91) Sample cock, housing, dimensions in mm (inch) 80 (3.15) G 1½ Sample cock, housing (left) and function unit The sample cock is a 2-way cock with a sealable housing. The vessel is fitted in the body of the cock. ssembly is carried out in horizontal pipelines, with the sample outlet pointing downwards. Otherwise the regulations of the German monopoly administration apply. Sample cock without housing, dimensions in mm (inch) Function The sample cock has two positions one for filling and one for emptying the vessel. The quantity of the samples is exactly proportioned: 20 cm³ (1.22 cu.in). The number of samples taken is indicated by a 6-digit drum-type counter. /360 Siemens FI
7 SITRNS F R Leakage indicator Leakage indicator The leakage indicator is used to indicate leaking liquids from vertical aeration and venting pipes with an outer diameter of 10 to 65 mm. Its area of application is in distillation plants and storage tanks. The leakage indicator is according to the German monopoly administration and approved for tax monitoring in Germany. The leakage indicator is made up of the following components: External glass tube Cork float Lipowitz metal loop Leakage indicator 7 M S Hollowing-out of collection tray With Outer diameter of air pipe for hollowing-out of collection tray With Ø 10 mm (0.39 inch) Ø 65 mm (2.56 inch) Siemens FI /361
8 /362 Siemens FI
SITRANS F flowmeters. SITRANS F R Meters for lubricating oils (distribution of mineral oils) 4/350 Siemens FI Overview
(distribution of mineral oils) Type For custody transfer use Not for custody transfer use Flow rate in l/min (USgpm) Flow rate in l/min (USgpm) Minimum Maximum Minimum Maximum Pistol-grip meter Without
More informationSITRANS F flowmeters SITRANS F I. Intra/Prima flap flowmeter. 4/284 Siemens FI
Intra flap flowmeter for transparent liquids Prima flap flowmeter for opaque liquids pplication The flap flowmeter is used to check and display the flow of liquids in closed pipelines. The device can be
More informationCONTOIL VZFA/VZOA , versions for higher requirements / applications
CONTOIL VZF/VZO 4...50, versions for higher requirements / applications For applications requiring an increased accuracy of ±0.5 % or better, such as: Measurement of L heating fuel or diesel in testing
More informationFlowmeter F I Gardex. Connection and installation instructions. Application. Benefits. Design and mode of operation
The baffle plate (b) causes a back-pressure in the medium, and the balance beam (c) is deflected. This movement is transmitted via the beam to the indicator mechanism (e) using a bellows bushing (d). gear
More informationSITRANS FX300 4/289. System Overview. Overview
Siemens G 2008 SITRNS F flowmeters Overview System Overview Version Single transmitter Dual transmitter Options Standard Pressure sensor Flange Pressure sensor and isola- Standard tion valve Sandwich vortex
More informationPressure Measurement Fittings
Siemens G 2018 Overview ll shut-off fittings can be secured onto walls, racks (72 mm grid) and vertical and horizontal pipes. This offers the advantage when assembling a plant that the shutoff fittings
More informationEUGEN WOERNER GmbH & Co. KG Postfach 1661 DE Wertheim Am Eichamt 8 DE Wertheim. Pump unit GMZ-E
Pump unit GMZ-E Pump used to supply oil and grease from a barrel directly through a lid-hole or a bunghole. Technical data: Pump with bung-hole Pump with barrel lid Delivery volume per stroke: Pump element
More informationSITRANS P measuring instruments for pressure
Overview Siemens AG 009 Supplementary electronics for 4-wire connection Design Dimensions (W x H x D) in mm (inch) Electrical connection 80 x 10 x 60 (3.15 x 4.7 x.36) Screw terminals (Pg 13.5 cable inlet)
More informationLC OVAL GEAR FLOWMETER
LC OVAL GEAR FLOWMETER DN10-DN25 DN50-DN100 Digital Register DN65 High Temp. DN150,DN200 DN50-DN100 General Description Oval gear flowmeters are instruments used for the continuous and intermittent measurement
More informationTechnical Data B20x. 8 BiRotor, APL. Model B201 [8 ] Model B203 [8 ] Model B204 [8 ] Model B205 [8 ]
Technical Data BiRotor, APL Model B201 [] Model B203 [] Model B204 [] Model B205 [] General The BiRotor Meter is a positive displacement meter utilized in the most demanding applications requiring accuracy,
More informationVolumeter TRZ 03-K PRODUCT INFORMATION. Reliable Measurements of Gas
Volumeter TRZ 0-K PRODUCT INFORMATION Reliable Measurements of Gas Method of operation, Construction Method of operation The TRZ 0-K Volumeter is a flow meter suitable for metering gases, where the rate
More informationSubmersible Long Shaft Pumps for the Chemical Industry Type NCT/NMT
Submersible Long Shaft Pumps for the Chemical Industry Type NCT/NMT General The DICKOW submersible pump, type NCT, for the chemical industry is a vertical pump with separate discharge pipe. The maximum
More informationSITRANS F flowmeters SITRANS F C MASSFLO MASS MC1. 4/146 Siemens FI Overview
Overview MSS 2100 MC1 DN 50 to DN 150 (2 to 6 ) is suitable for accurate mass flow measurement for all kind of liquids and gases. The sensor offers superior performance in terms of flow accuracy, turn-down
More informationMechanical pressure gauges
J Bourdon tube pressure gauges J Differential pressure gauges J Diaphragm pressure gauges J capsule element pressure gauges Mechanical pressure gauges J Contains products with: DS_Mechanical_pressure_gauges
More informationSeries 240 Type and Type Pneumatic Control Valves Type 3248 Cryogenic Valve
Series 240 Type 3248-1 and Type 3248-7 Pneumatic Control Valves Type 3248 Cryogenic Valve ANSI version Application Globe or angle valve for cryogenic applications Easy to service due to top-entry design
More informationSITRANS F flowmeters SITRANS F C
SITRNS F flowmeters Siemens G 2008 Overview is available as a standard version (DN 50 to DN 150 (2 to 6 )) and a hygienic, EHEDG certified version (DN 20 to DN 80 (¾ to 3 )). MC2 and MC2 hygienic are suitable
More informationRMG Meßtechnik GmbH. Publication No E
Turbine meter TRZ 03 RMG Meßtechnik GmbH Publication No. 3.161-E P.O.Box 80 D-3550 Butzbach (Germany) Phone: +49 (0)6033 897-0 Fax: +49 (0)6033 897-130 E-mail: messtechnik@rmg.de Web site: http://www.rmg.de
More informationVolumeter. RMG Meßtechnik GmbH. Publication No E
Volumeter TRZ 03-K RMG Meßtechnik GmbH Publication No. 3.171-E P.O.Box 80 D-3550 Butzbach (Germany) Phone: +49 (0)6033 897-0 Fax: +49 (0)6033 897-130 E-mail: messtechnik@rmg.de Web site: http://www.rmg.de
More informationFood & beverage. Oil & gas. Water & waste water
Overview MSS 2100 MC1 DN 50 to DN 150 (2 to 6 ) are suitable for accurate mass flow measurement for all kind of liquids and gases. The sensor offers superior performance in terms of flow accuracy, turn-down
More informationSelf-operated Pressure Regulators Type Universal Excess Pressure Valve
Self-operated Pressure Regulators Type 41-73 Universal Excess Pressure Valve Application Pressure regulators for set points from 0.05 to 8 bar Valve nominal sizes DN 15 to 100 Nominal pressure PN 16 to
More informationSITRANS F flowmeters SITRANS F C SITRANS F C MC2 4/169. Overview
Siemens G 2009 SITRNS flowmeters SITRNS C SITRNS C MC2 Overview SITRNS C MC2 is available as a standard version (DN 50 to DN 150 (2 to 6 )) and a hygienic, EHEDG-certified version (DN 20 to DN (¾ to 3
More informationMake sure that no hazardous fumes can build up in the piping and in the meter during commissioning, decommissioning and dismantling.
The device and its accessories must only be used for their intended purpose and comply with safety regulations. Aquametro devices are manufactured according to valid standards and guidelines. Aquametro
More informationFZ-A Lubricator. Electric, Oil & Grease. General. Application. Operation. Features. Adjustment of Discharge Rate R2 03/09
FZ- Lubricator Electric, Oil & Grease General The FZ- Lubricator is primarily designed for direct feed applications for servicing up to 12 lubrication points. The lubricators are supplied with pump bodies
More informationHydraulics. Axial Piston Pumps Series PVP. Introduction. With thru shaft option for multiple pump options Swash plate type for open circuit
Introduction *not included Pump with standard compensator, code: "omit" With thru shaft option for multiple pump options Swash plate type for open circuit Pump with load sensing, code: "A" Mounting style
More informationVZFA/VZOA MISURATORI DI PORTATA FUEL OIL METERS. CONTOIL VZFA/VZOA , versions for special requirements / applications
VZFA/VZOA FUEL OIL METERS MISURATORI DI PORTATA CONTOIL VZFA/VZOA 5...50, versions for special requirements / applications For applications requiring an increased accuracy of ± % or better, such as: Versions
More informationSeries 240 Type and Type Pneumatic Control Valves Type 3248 Cryogenic Valve
Series 240 Type 3248-1 and Type 3248-7 Pneumatic Control Valves Type 3248 Cryogenic Valve ANSI version Application Globe or angle valve for cryogenic applications Easy to service due to top-entry design
More informationMetal tube variable area flowmeter for gases, liquids and steam
Metal tube variable area flowmeter for gases, liquids and steam Metallic or plastic tube with a robust construction Indication by means of magnetic coupling Scales calibrated in l/h, m 3 /h, kg/h, t/h,
More informationDifferential Pressure and Flow meters Accessories for the Media Series
Differential Pressure and Flow meters Accessories for the Media Series 7 8 9 10 11 6 12 Media 5 Media 6 Media 05 1 5 2 4 Media 4 3 Selection and application These accessories upgrade the devices of the
More informationSeries 42 Self-operated Regulators. Type RS Check Valve (backflow protection)
Series 42 Self-operated Regulators Type 42-10 RS Check Valve (backflow protection) Application Designed to protect nitrogen and compressed air networks against backflow from directly connected systems.
More informationVZ-01. Features. Oil Counter for Light to Heavy Fuel Oil. Description: Application: / Mounting on pressure or suction side
VZ-01 Oil Counter for Light to Heavy Fuel Oil Description: Features / Mounting on pressure or suction side The VZ-01 series of volume counters are rotary piston meters that function without auxiliary electrical
More informationSelf-operated Pressure Regulators Type Universal Excess Pressure Valve
Self-operated Pressure Regulators Type 41-73 Universal Excess Pressure Valve ANSI version Application Pressure regulator for set points from 0.75 to 400 psi (0.05 to 28 bar) Valves in NPS ½ to 4 (DN 15
More informationLiquid ring vacuum pumps with magnetic coupling
Liquid ring vacuum pumps with magnetic coupling LPH 75320, LPH 75330, LPH 75340 Pressure range: Suction volume flow: 33 to 1013 mbar 485 to 1615 m³/h CONSTRUCTION TYPE Sterling SIHI liquid ring vacuum
More informationSIHI prime - Side Channel Pumps Self-priming, segmental type
SIHI prime - Side Channel Pumps Self-priming, segmental type AKH-X 1201 3606 TECHICAL DATA Capacity: Delivery head: Speed: from 0.4 up to 7.5 m³/h from 10 up to 242 m 1450 rpm (max. 1800 rpm) Temperature:
More information3 & 4-Way Rotary Valves
Applications: 3-way Valve 4-way Valve The ESBE 3 and 4-Way rotary valves type F are designed for mixing or diverting applications on heating and cooling systems. The valves are capable of controlling and
More informationSITRANS F flowmeters. SITRANS F O delta p - Primary differential pressure devices Metering pipe with orifice plate and annular chambers 4/369
and annular chambers Application Suitable for non-corrosive and corrosive gases, vapors and liquids; permissible operating temperature -10 to +00 C. Design Orifice plate with annular chambers consisting
More informationSectional Directional Control Valve RSQ 240
Sectional Directional Control Valve RSQ 0 Key valve features RSQ 0 is a sectional open center valve, designed for max. operating pressures up to 50 bar and max. pump flows up to 00 l/min. It is available
More informationElectropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN
Electropneumatic Converters i/p Converters Type 6111 Fig. 1 Type 6111 in standard version Fig. Type 6111 mounted on a supply air manifold Fig. 3 Type 6111 in field enclosure Mounting and Operating Instructions
More informationLIQUID MEASUREMENT STATION DESIGN Class No
LIQUID MEASUREMENT STATION DESIGN Class No. 2230.1 Michael Frey Systems Sales Manager Daniel Measurement & Control, Inc. 5650 Brittmoore Rd. Houston, Texas 77041 INTRODUCTION The industry continues to
More informationUltra-Matic Air Valve System
Ultra-Matic Air Valve System Efficient Pumps, Competitive Upgrades and Accessories U2 Plastic Pumps Metallic Pumps Specialty Pumps Upgrade Kits Accessories Diaphragms Ultra-Matic Air Valve Technology Simple.
More informationBM SERIES METERS PRECISION POSITIVE DISPLACEMENT METERS THE LEADER IN ACCURATE, LONG-LIFE, FUEL METERING INDUSTRY LEADING ACCURACY (+/-.
BM SERIES METERS PRECISION POSITIVE DISPLACEMENT METERS THE LEADER IN ACCURATE, LONG-LIFE, FUEL METERING INDUSTRY LEADING ACCURACY (+/-.05% * ) 110 TO 0 LPM (30 TO 1000 GPM) FLOW RATES * subject to meter
More informationAssembly. 1 Compact version with valve plug 2 Short tube version with cable 3 Compact version with M12 plug 4 Short tube version with M12 plug
Vibration Limit Switch Features Limit switch for liquids External function test with test magnet Onsite function check possible thanks to LED indication Large selection of process connections for hassle-free
More informationANSI version. The valve closes when the differential pressure rises
Self-operated Regulators Series 42 Differential Pressure Regulator with Type 2424/Type 2428 Actuator and Type 2422 Valve Type 42-24 A Type 42-24 B Type 42-28 A Type 42-28 B ANSI version Application For
More informationSIHI LPH-X - Liquid Ring Vacuum Pump Two Stage
- Liquid Ring Vacuum Pump Two Stage 45008, 45311, 45316 Pressure Range: Suction Volume: 33 to 1013 mbar 55 to 258 m³/h CONSTRUCTION Sterling SIHI liquid ring vacuum pumps have a simple but robust construction
More informationType and Type Pneumatic Control Valves Type 3510 Micro-flow Valve
Type 3510-1 and Type 3510-7 Pneumatic Control Valves Type 3510 Micro-flow Valve ANSI version Application Control valve especially designed for controlling low flow rates in pilot plants and technical research
More informationtekson TS Series Low Cost Ultrasonic Water Energy Flow Measurement
Sensing the pulse of industry tekson TS Series Low Cost Ultrasonic Water Energy Flow Measurement tekflo sensors are proud to present their tekson TS Series ultrasonic water energy meter, which uniquely
More informationSITRANS F C. Flow sensor MC2 4/193. Overview
Siemens G 2011 low Measurement SITNS C Overview The main applications of the Coriolis flowmeter can be found in all industries, such as: Chemical and pharma Detergents, bulk chemicals, pharmaceuticals,
More informationSelf-operated Pressure Regulators Type Universal Pressure Reducing Valve
Self-operated Pressure Regulators Type 41-23 Universal Pressure Reducing Valve ANSI version Application Pressure regulators for set points from 0.75 to 400 psi (0.05 to 28 bar) Valves in NPS ½ to 4 (DN
More information1/2-2 INSTALLATION INSTRUCTIONS
1/2-2 INSTALLATION INSTRUCTIONS ZE Table of contents General Meter Configuration 1 Application, planning and installation 1 Safety precautions 1 Plant design Layout of piping 2 -Meter installation 2 -Correct
More informationA6 type. General universal type. Submerged type Connector box type. Installation method Titanium PPS FKM
Industrial Conductivity (Electric Conductivity) Detector A5/A6 type (For general multipurpose) AR4/AR5 type (for small purified water equipment) Dual electrode conductivity (electrical conductivity) detector
More informationMOBILE GREASE UNITS WITH PUMPMASTER 3+3 PUMPS - 20 AND 50 pumps
PUMPMASTER 2 oil pumps MOBILE GREASE UNITS WITH PUMPMASTER 3+3 PUMPS - 20 AND 50 pumps Kg. 000 000 Iquip iriuscidunt nosand niammeters ver ip fluidmodit dispense guns control valves for oil......................................................
More informationFlow Measurement SITRANS F C
Siemens G 2014 SITRNS C Overview The main applications of the Coriolis flowmeter can be found in all industries, such as: Chemical and pharma Detergents, bulk chemicals, pharmaceuticals, acids, alkalis
More informationVariable Vane Pump, Direct Controlled PV7...A Series 1X / 2X
Variable Vane Pump, Direct Controlled PV7...A Series 1X / X RE 1 Issue: 1.13 Replaces: 8.8 Sizes 1 to Maximum pressure 1 bar Displacement volume 1 to cm 3 Features Very short control times Low noise Mounting
More information6" Steel Model G6. Smith Meter Rotary Vane PD Meters. Features. Operating Specifications Maximum Flow Rate. Options
SPECIFICATIONS 6" Steel Model G6 Bulletin SS01014 Issue/Rev. 1.0 (4/18) Smith Meter Rotary Vane PD Meters The Smith Meter Model G6 Meter is a 6", double-case, straight-through rotary vane type positive
More informationMetal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam
Metal tube flowmeters Variable area flowmeter for liquids, gases and steam Metallic or plastic tube with a robust construction Indication by means of magnetic coupling Scales calibrated in l/h, m 3 /h,
More informationTEK-F LUX 1400A. Electromagnetic Flowmeter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys FLOW
Technology Solutions TEK-F LUX 1400A Electromagnetic Flowmeter FLOW www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction Electromagnetic flowmeters are also
More informationSealless Magnetic Coupled Hot Oil Circulation Pumps acc. to DIN EN / ISO 2858 Type NMWR / NMWB / NMW. our. contribution for
Sealless Magnetic Coupled Hot Oil Circulation Pumps acc. to DIN EN 22858 / ISO 2858 Type NMWR / NMWB / NMW our contribution for environmental protection General DICKOW pumps of series NMWR / NMWB / NMW
More informationSIHI prime - Side Channel Pumps Self-priming, segmental type with very low NPSH
SIHI prime - Side Channel Pumps Self-priming, segmental type with very low NPSH CEH-X 1201 3608 TECHICAL DATA Capacity: Delivery head: Speed: from 0.4 up to 7.5 m³/h from 10 up to 322 m 1450 rpm (max.
More informationSITRANS F M flow sensors 711/A and 711/911E
s flow sensors 711/A and 711/911E flow sensors 711/A and 711/911E Introduction Application Mode of operation, operation Mode of operation All electromagnetic flow measurements are based on Faraday s Law
More informationBypass level indicator With magnetic display Model BNA for nuclear power plants
Level measurement Bypass level indicator With magnetic display Model BNA for nuclear power plants KSR data sheet BNA for NPP Applications Continuous level indication without power supply Indication of
More informationULTRASONIC FLOW SENSOR IFX-M4-01
ULTRASONIC FLOW SENSOR IFX-M4-01 TECHNICAL DESCRIPTION, OPERATING INSTRUCTION IFX-M4-01 2012-09-10 TABLE OF CONTENTS 1. APPLICATION... 3 2. TECHNICAL DATA... 4 3. PACKAGE CONTENT... 6 4. OPERATING PRINCIPLE...
More informationSITRANS F flowmeters SITRANS F US. SITRANS FUT1010 Ultrasonic flowmeter. Overview. Application
Overview SITRANS F flowmeters Application Liquid applications Gas applications Pipelines Custody transfer, allocation, Upstream Production wells, line balance, gathering, separation interface/densitometer
More informationSeries 240 Type and Type Pneumatic Control Valves Type 3244 Three-way Valve
Series 240 Type 3244-1 and Type 3244-7 Pneumatic Control Valves Type 3244 Three-way Valve DIN and ANSI versions Application Mixing or diverting valve for process engineering and industrial applications
More informationTechnical Data. Series Oval Flowmeter. Model 9400
Technical Data Series Oval Flowmeter Model 9400 General The Brodie 9400 Series Oval Flowmeters, Models 9402 through 9459 (sizes 1/2-3 ), are mechanical, positive displacement meters designed for use in
More informationBennett Pump Company
Bennett Pump Company SB-100 Meters Operation, Service & Parts Manual Only Trained Personnel May Work on This Equipment For more information, please contact: Jim Biesecker, Component Sales 1218 E. Pontaluna
More informationSystem 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter
System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter Application Used to convert a direct-current input signal into a pneumatic output signal for measuring and control
More informationFT-1000/FP-1000 FLOAT TYPE TANK GAUGES SIMPLE, RELIABLE, COST EFFECTIVE. The FT-1000 or FP-1000 series is a mechanical level gauge with a float.
SIMPLE, RELIABLE, COST EFFECTIVE FT-1000/FP-1000 FLOAT TYPE TANK GAUGES The FT-1000 or FP-1000 series is a mechanical level gauge with a float. The FT-1000 is a conventional float-tape level gauge with
More informationMaintenance-free metal-seated globe valves. Grey cast iron PN 16 DN Nodular cast iron PN 16 DN Nodular cast iron PN 25 DN
Type Series Booklet 7150.1/9-10 BOA -H Maintenance-free metal-seated globe valves with bellows Grey cast iron PN 16 DN 15-300 Nodular cast iron PN 16 DN 15-350 Nodular cast iron PN 25 DN 15-150 Applications
More informationSelf-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23
Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23 ANSI version Application Pressure regulators for set points from 0.075 to 400 psi (5 mbar to 28 bar) Valves in NPS ½ to 4
More informationHYDROKOMP. Clamping Systems. Technology that connects. precise durable varied. Brand name products by Hydrokomp
HYDROKOMP Clamping Systems precise durable varied Brand name products by Hydrokomp Technology that connects HYDROKOMP GmbH Siemensstraße 16, 35325 Mücke (Germany) Phone: +49 6401 225999-0 Fax: +49 6401
More informationMobrey MLT100. Displacer Level Transmitter. Product Data Sheet February 2015 IP119, Rev CA. Level, contents or interface measurement transmitter
Product Data Sheet February 2015 IP119, Rev CA Displacer Level Transmitter Level, contents or interface measurement transmitter Direct or external chamber mounting 4 20 ma HART output ATEX Intrinsically
More informationMagnetic-inductive flow meter EPS / UMF2. Technical data sheet
Magnetic-inductive flow meter EPS / UMF2 Technical data sheet high accuracy: 0.3 % of actual maintenance-free no pressure drop numerous lining materials numerous electrode materials low-cost grounding
More informationSeries 240 Type 3351 Pneumatic On/off Valve
Series 240 Type 3351 Pneumatic On/off Valve Application Shut-off valve with tight shut-off for liquids, gases and vapors according to DIN or ANSI standards Valve size DN 15 to 100 NPS ½ to 4 Pressure rating
More informationLarge Electronically Adjustable Proportional Pressure Compensated Flow Control Engineering & Manufacturing Solutions
Engineering & Manufacturing Solutions LEFC Specifications: See flow chart for capacity. Max. 3000 psi cartridge input pressure. Nominally Rated for 3000 psi (207 bar). Tank Port - #4 SAE (10 psi (0.69
More informationScrew-type and measuring capsule heat meter with IrDA interface and an interface for retrofitting external modules or with integrated communication.
Data sheet DST2-QHEA-GB0 HMx / 11.05.2016 - V 1.0 Heat meter Q heat 5 Screw-type and measuring capsule heat meter with IrDA interface and an interface for retrofitting external modules or with integrated
More informationPLC-3000 zfa01. Portable Fluid Analysis. Global Filtration Technology
zfa01 Global Filtration Technology 157 Why on-site fluid analysis? Certification of fluid cleanliness levels Immediate and accurate results Early warning tool to help prevent catastrophic failures in critical
More information9400 Series Oval Flowmeter
Design Specifications DS9400 Revision 03 9400 Series Oval Flowmeter High accuracy Simple, durable construction Low maintenance requirements Easy access 3 piece design Choice of materials of construction
More informationGRUNDFOS DATA BOOKLET. Grundfos UPBasic. Circulator pumps 50 Hz
GRUNDFOS DATA BOOKLET Grundfos UPBasic Circulator pumps 50 Hz Contents General data Performance ranges Page Product range, 1 x 0 V, 50 Hz Page 4 Type key Page 4 Construction Page 4 Material specification
More informationM-11 MARINE DIESEL ENGINE FUEL INJECTOR
Guideline No.M-11(201510) M-11 MARINE DIESEL ENGINE FUEL INJECTOR Issued date: 20 October 2015 China Classification Society Foreword This Guideline constitutes the CCS rules, and establishes the applicable
More informationOrifice flowmeter F O N4
Special features Suitable for any mounting positions without reduction in accuracy Complies with requirements for treatment and disinfection of swimming/ bathing pools (DIN 9 643) Simple installation Direct
More informationThe full WeatherTRAK Flow3 Installation and Maintenance Manual is available online at
Installation Manual INTRODUCTION The full WeatherTRAK Flow Installation and Maintenance Manual is available online at www.weathertrak.com General Description A WeatherTRAK Flow combines a hydraulic master
More informationFlowmeter DFM
Flowmeter DFM 165 50 Nominal size DN 10-65 Nominal size /8 2 1/2 Nominal pressure PN 10 bar Features Measuring range to 50,000 l/h suitable for a wide range of applications for gaseous medium types, water,
More informationSIHI LPH-X - Liquid Ring Vacuum Pump Two Stage
- Liquid Ring Vacuum Pump Two Stage LPH 45008, LPH 45311, LPH 45316 Pressure Range: Suction Volume: 33 to 1013 mbar 55 to 258 m³/h CONSTRUCTION Sterling SIHI liquid ring vacuum pumps have a simple but
More informationMFP14, MFP14S and MFP14SS Automatic Pumps
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More information:1 3:1 5:1 3:1 3:1 5:1 3:1 3:1 5:
trolley for drums 30-60 kg kit for drums 30-60 kg 35260 35250 37500 35249 35259 37499 35264 35254 37504 3:1 3:1 5:1 3:1 3:1 5:1 3:1 3:1 5:1 20 14 18 20 14 18 20 14 18 35076 35173 36073 35076 35173 36073
More informationSECTION H3 TRAYMASTER SERIES DEAERATORS
SECTION H3 TRAYMASTER SERIES DEAERATORS SAMPLE SPECIFICATIONS PART 1 GENERAL... H3-12 1.1 Packaged Deaerator Specification... H3-12 PART 2 PRODUCTS... H3-12 2.1 Deaerator... H3-12 2.2 Deaerator Vessel...
More informationContents. Identification
Contents Identification Type key Product data Introduction Applications Features and benefits Performance range pole pole Construction Sectional drawing Construction features Test pressure Operating conditions
More informationVZO Pressure drop curves See Meter data. Option: Reed pulser or RV / IN pulser
VZO 15...50 Technical data 1) Volume display on roller counter, in litres fuel oil meter with threaded or flanged ends for horizontal, vertical or inclined mounting Option: Reed pulser or RV / IN pulser
More informationPressure sensor for liquid and gaseous media QBE620-P...
1 904 Pressure sensor for liquid and gaseous media QBE620-P... Pressure sensor for the measurement of positive pressure in HVAC applications. Piezo-resistive system of measurement DC 0...10 V output signal
More informationUFM 800 W, C and UFM 800 W Hot Tapping. Ultrasonic flowmeters. for water and wastewater
KROHNE 12/2006 7.02343.22.00 MAR UFM 800 W, C and UFM 800 W Hot Tapping Ultrasonic flowmeter for water and wastewater...with weld-in sensors for metal pipelines...with built-on or built-in sensors for
More informationLBTC Series Positive Displacement Rotary Vane Flow Meters
LBTC Series Positive Displacement Rotary Vane Flow Meters Summary LBTC Series positive displacement rotary vane flow meters are independently designed and manufactured by our company on the base of absorbing
More informationOscillating piston flowmeters Series COVOL Positive displacement flowmeter for liquids
Oscillating piston flowmeters Series COVOL Positive displacement flowmeter for liquids Suitable for all kind of liquids Viscosity up to 120000 mpa s Excellent performance with changing process conditions
More informationFixed Displacement Bent Axis Axial Piston Pumps TPB 70 - TAP 70
HYDRAULIC COMPONENTS HYDROSTATIC TRANSMISSIONS GEARBOXES - ACCESSORIES Certified Company ISO 9001:2015-14001:2015 ISO 9001:2015 Certificate N 12-Q-0200545-TIC ISO 14001:2015 Certificate N 12-E-0200545-TIC
More informationData Sheet T EN
Data Sheet T 8015-1 EN Series 240 Types 3241 1 PSA, -7 PSA, -9 PSA Pneumatic Control Valves Type 3241 PSA Globe Valve Application Control valves for PSA plants (Pressure Swing Adsorption) Valve sizes DN
More informationGRUNDFOS alldos product information. The digital diaphragm dosing pump for difficult liquids
GRUNDFOS alldos product information The digital diaphragm dosing pump for difficult liquids Digital Dosing The Highlights Easy input and display of the dosing rate in l/h or gal/h with perfect calibration
More informationBGN. All Metal Variable Area Flow Meter. Technical Data Sheet
All Metal Variable Area Flow Meter BGN Technical Data Sheet Extremely robust through star guiding system instead of guiding rod Flow metering of liquids, gases and steam Available up to nominal size of
More informationSeries 240 Pneumatic On-off Valve Type 3351
Series 240 Pneumatic On-off Valve Type 3351 Application Control valve with a tight shutoff of liquids, gases and steam in accordance with DIN or ANSI standards Nominal sizes DN 15 to 100 NPS ½ to 4 Nominal
More informationTECHNICAL INFORMATION
General Nomenclature Spherical Roller Bearings The spherical roller bearing is a combination radial and thrust bearing designed for taking misalignment under load When loads are heavy, alignment of housings
More informationLevel instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview.
Overview Configuration is an inverse frequency shift capacitance continuous It is ideal for standard industrial applications in chemical, hydrocarbon processing, food and beverage and mining, aggregate
More information3" Steel Model E3. We put you first. And keep you ahead.
SPECIFICATIONS MEASUREMENT SOLUTIONS 3" Model E3 Bulletin SS01016 Issue/Rev. 1.1 (2/15) We put you first. And keep you ahead. SMITH METER PD METERS The Smith Meter Model E3 is a 3", double-case, straightthrough
More informationSeries 240 Type Gas and Type Gas Automatic Shut-off Valves for Gases (valve class D)
Series 240 Type 3241-1-Gas and Type 3241-7-Gas Automatic Shut-off Valves for Gases (valve class D) DIN-DVGW typetested acc. to DIN EN 161 (2013-04) Application Control valve for control systems subject
More information