WESCHLER INSTRUMENTS. Weschler Analog Switchboard Meters TAUT-BAND SUSPENSION FULL VIEW DESIGN MODIFICATIONS AVAILABLE.

Size: px
Start display at page:

Download "WESCHLER INSTRUMENTS. Weschler Analog Switchboard Meters TAUT-BAND SUSPENSION FULL VIEW DESIGN MODIFICATIONS AVAILABLE."

Transcription

1 Weschler Analog Switchboard Meters High accuracy, full view design Volts, amps, watts, vars, speed, frequency and power factor High overload capacity Military and Nuclear versions Ultimate in reliability and performance Special scales and calibration Formerly Westinghouse brand TAUT-BAND SUSPENSION Type K-241 & 261 instruments, except those which rotate continuously, use taut-band suspension. The taut-band suspension has unique advantages over the conventional pivot and jewel movement: It eliminates friction, giving better accuracy and almost perfect repeatability. It gives top performance under adverse conditions of shock and vibration. It reduces maintenance, thereby saving money throughout the lifetime of the instrument. It assures longer life, reducing annual depreciation and replacement costs. It has greater sensitivity, reducing power burdens on circuits being measured. Type K-241 & 261 instruments are designed to achieve the ultimate in reliability and performance. These instruments are recommended for use on electric utility switchboards and industrial process control panels. Commercial instruments comply with ANSI Standard C39.1 for 1% class switchboard instruments. The Hi-Shock versions were developed to meet the special needs of U.S. Navy shipboard applications. They are also suitable for commercial, marine and industrial applications subjected to humid conditions or severe mechanical shocks. Types Available FULL VIEW DESIGN To facilitate quick, accurate reading, even under adverse conditions, all K-241 instruments feature the Westinghouse full view 250 design. The window is flat, reducing light reflection to minimize the need for a non-glare surface. The dial scale is beveled for a 60 viewing angle. KX241 MODIFICATIONS AVAILABLE DIALS: Black Dual Scale Special Colors, Legends Weather resistant Cover ELECTRICAL: Intermediate Ratings Special Calibrations Offset or Suppressed Zero Multiple Rating Special Sensitivity Function Ranges Type Designation Mechanism DC Microammeter 50µA to 1mA KX-241 Com & HI, 241 Com Permanent-magnet moving coil DC Milliameter 1mA to 1A KX-241 Com & HI, 241 Com Permanent-magnet moving coil DC Ammeter 1A to 50A KX-241 Com & HI, 241 Com Permanent-magnet moving coil DC Millivoltmeter 50mV to 1V KX-241 Com & HI, 241 Com Permanent-magnet moving coil DC Voltmeter 1V to 800V KX-241 Com & HI, 241 Com Permanent-magnet moving coil AC Milliammeter 10mA to 1A KA-241 Com & HI, 261 Com Iron Vane AC Ammeter 1A to 20A KA-241 Com & HI, 261 Com Iron Vane AC Voltmeter 10V to 750V KA-241 Com & HI, 261 Com Iron Vane AC Frequency 50, 60 & 400Hz KX-241 Com & HI With Separate Transducer AC Frequency 50, 60 & 400Hz KR3-241 Com Self Contained Transducer AC Frequency Hz KR4-241 HI Self Contained Transducer AC Power Factor KI-241 Com & HI, 261 Com Rotating Vane AC Power Factor KJ-241 Com Self Contained Transducer AC Synchroscope -- KI-241 Com & HI, 261 Com Rotating Vane AC Wattmeter 0.1 to 10A KP-241 Com & HI, 261 Com & HI Self Contained Transducer AC Varmeter 0.1 to 10A KP-241 Com & HI, 261 Com&HI With External Phase Shifte AC Varmeter.1 to 10A KV-241 Com & HI, 261 Com & HI Self Contained Transducer Rectifier Milliammeter 1mA to 1A KC-241 Com & HI, 261 Com Permanent-magnet moving coil Rectifier Ammeter 1A to 17A KC-241 Com & HI, 261 Com Permanent-magnet moving coil Rectifier Voltmeter 5V to 600V KC-241 Com & HI, 261 Com Permanent-magnet moving coi Resistance Thermometer All Popular Ranges KX-241 Com & HI, 261 Com Self Contained Bridge Speed Indicator 0-25, up to 13000pps KX-241 Com & HI, 261 Com Self Contained Transducer Synchrotie KS-241 Com, Unmounted Transmitter Self-Synchronous 48

2 49 AC/DC Amps, Volts and Frequency To Order Insert Number Code for Each Letter to Select Catalog Number. Order Example: A42 (0-150) A B Basic Unit DC Ammeters and Voltmeters AC Ammeters and Voltmeters Frequency Meters Rating and Scale DC Ammeter DC Voltmeter AKM 500 madc VNL 30 VDC ALA 1 ADC VNT 50 VDC ALS 5 ADC VPK 100 VDC AMT 10 ADC VPZ 150 VDC AND 15 ADC VRX 300 VDC ANG 20 ADC V01 1 madc ANL 30 ADC madc A01 50 mvdc madc A mvdc VDC AC Ammeter AC Voltmeter AKG 300 maac VPK 100 VAC AKM 500 maac VPZ 150 VAC ALA 1 AAC V VAC(for PT) ALC 1.5 AAC VRX 300 VAC ALS 5 AAC VSI 600 VAC A42 5 AAC (for CT) V VAC* AMF 7.5 AAC V VAC* AMT 10 AAC * Expanded Scale ANL 30 AAC Frequency Meter H40 115V Hz H60 230V Hz H41 115V Hz H61 230V Hz H42 115V Hz H62 230V Hz Yokogawa Mini Switchboard Meters A B 2182 Accuracy ±1.5% of FS basic accuracy class Rectifier Instruments 25 C calibrated on sine Operating Temperature Range 0 40 C (32 F 104 F) Dielectric Level 2,600 VAC for 1 minute between circuit & case Overload Rating Voltmeter or potential coils 1.2x continuous; AC ammeters 2x continuous, 10x for 1 second; Current coils other than AC ammeters 1.5x continuous, 10x for 1 second Response Time Approx. 2.5 seconds Position of Use Vertical (scale) Full Scale Deflection Angle/Length 250 /5.5 Case ABS resin, black Size (H x W x D) 3.18" x 3.18" x 4.35" Barrel (cutout) 2.84" Dia. Mini Switchboard Series Compact Size 3" Case Rugged, Durable Construction No Shadows on Scale Accurate and Readable, Even from Sharp Angles Accurate to Within ±1.5% of Full Scale Attractive, Uncluttered Scales Weathertight Construction Ideal for Adverse Conditions Taut-Band Suspension Watt, Var & Power Factor To Order Insert Number Code for Each Letter to Select Catalog Number. Order Example: W56 A B C A Basic Unit 2185 AC Wattmeters 2186 AC Varmeters 2187 AC Power Factor Meter B Function/Connection Watts 31 Single Phase 34 Three Phase, Four Wire 35 Three Phase, Three Wire-Unbalanced 36 Three Phase, Four Wire-Unbalanced Vars 31 Single Phase 33 Three Phase, Three Wire 34 Three Phase, Four Wire 35 Three Phase, Three Wire-Unbalanced 36 Three Phase, Four Wire-Unbalanced Power Factor 31 Single Phase 33 Three Phase, Three Wire 35 Three Phase, Three Wire-Unbalanced 36 Three Phase, Four Wire-Unbalanced C Input Watts VARs Power Factor W55 120V-1A AC M55 120V-1A AC C55 120V-1A AC W56 120V-5A AC M56 120V-5A AC C56 120V-5A AC W65 240V-1A AC M65 240V-1A AC C65 240V-1A AC W66 240V-5A AC M66 240V-5A AC C66 240V-5A AC OPTIONS (WHERE APPLICABLE) Custom Scaling Nonstandard Ranges Adjustable Potentiometer (Voltmeters Only) Color Bands 2185 In accordance with ANSI Specifications C39.1 Accuracy: Power Factor ±50% Accuracy: Watts/VARS ±1.5% of FS value Operating Temperature Range 0 40 C (32 F 104 F) Dielectric Level 2,600 VAC for 1 minute between circuit & case NOTE: All units supplied with external transducers. Except balanced Power Factor Meter. Click Here to Order Online

3 Yokogawa Power Factor, Frequency & Synchroscope Meters Rugged, Durable Construction Click Here to Order Online No Shadows on Scale Accurate and Readable, Even from Sharp Angles Accurate to Within ±1% of Full Scale Attractive, Uncluttered Scales Weathertight Construction Ideal for Adverse Conditions (AB-40) Easy to Read up to 30 Feet Away Taut-Band Suspension Except Synchroscopes AB-16 Power Factor AB-40 AB-16 Amperes Volts Scale Cat. No. Cat. No. Single-Phase 2 Wire 60 Hz FCAD FCAD 3-Phase 3 & 4 Wire, 50 & 60 Hz, Balanced System Only FCAD FCAD 5 208* CCAD CCAD FEAD FEAD FFAD FFAD FGAD FGAD 3-Phase 3 Wire, 50/60 Hz, Unbalanced Systems FCAD FEAD 3-Phase 4-Wire, 50/60 Hz, Unbalanced Systems FCAD CCAD FEAD Frequency Meters, 120V Rated Scale Center AB-40 AB-16 (Hz) Freq, Hz Cat. No. Cat. No AGAG AGAG AJAJ AJAJ AKAK AKAK ALAL ALAL ANAN ANAN ATAT ATAT ASAS ASAS BHBH BHBH BLBL BLBL Synchroscopes Pivot and Jewel 120 Volt Rated Scale Normal AB-40 AB-16 Freq. Cat. No. Cat. No. Slow-Fast ABAA ABAA Slow-Fast AAAA AAAA Slow-Fast ACAA ACAA * Line to line 208V (120V line to neutral) + Line to line ++ Line to neutral AB-40 In accordance with ANSI Specifications C39.1 Accuracy ±1% of FS basic accuracy class Rectifier Instruments ± C calibrated on sine wave Power Factor Meters ±1% of scale length Balanced system (20-100% rated current) Unbalanced system (±3% of scale length) Frequency Meters 45 Hz 55 Hz, ±0.15 Hz 55 Hz 66 Hz, ±0.15 Hz 58 Hz 62 Hz, ±0.093 Hz 350 Hz 450 Hz, ±1.5 Hz Operating Temperature Range 0 40 C (32 F 104 F) Dielectric Level 2,300 VAC for 1 minute between circuit and case Overload Rating Voltmeter or potential coils, 1.2x continuous AC ammeters, 2x continuous, 10x for 1 second. Current coils other than AC ammeters, 1.5x continuous, 10x for 1 second Response Time Approx. 2.5 seconds (except AB/DB-16) Position of Use Vertical (scale) Full Scale Deflection Angle 250 Case Size Model Size (H x W x D) Barrel (Cutout) Scale Length 4 1 4" AB " x 4.33" x 6.75" 4.03" 6.9" 4 1 4" AB " x 4.33" x 6.75" 4.03" 6.9" 8 3 4" AB " x 8.69" x 6.75" 4.03" 13.8" 54

4 Crompton Switchboard Meters 250 Linear Scale AC Instruments with True RMS Circuit UL/CSA Approvals Oil Dampened Mechanisms AC/DC SWITCHBOARD METER Accuracy: ±1% Full Scale Response Time: Approx. 2.5 Seconds to Full Scale Scale Arc: 250 Full Scale Deflection Position Use: Vertical (Scale) Overshoot: 33% Maximum Dielectric Withstand: 2300 VAC for 1 Minute Operating Temperature: -20 C to 65 C Size (H x W x D): 4.30" x 4.30" x 2.20" AC AMMETERS - RMS READING SELF CONTAINED 4 1 /2" Square Flange Standard Case Hi-Shock Case Rating Scale Catalog Number Catalog Number 1A 0-1A -05FA-LALA-C FJ-LALA-C6 1.5A 0-1.5A -05FA-LCLC-C FJ-LCLC-C6 2A 0-2A -05FA-LELE-C FJ-LELE-C6 3A 0-3A -05FA-LJLJ-C FJ-LJLJ-C6 5A 0-5A -05FA-LSLS-C FJ-LSLS-C6 7.5A 0-7.5A -05FA-MFMF-C FJ-MFMF-C6 10A 0-10A -05FA-MTMT-C FJ-MTMT-C6 15A 0-15A -05FA-NDND-C FJ-NDND-C6 20A 0-20A -05FA-NGNG-C FJ-NGNG-C6 30A 0-30A -05FA-NLNL-C FJ-NLNL-C6 Insert 077 for 4 1 2" Case, 079 for 8 1 2" Case AC AMMETERS - RMS READING TRANSFORMER RATED 5A 0-10A -05FA-LSMT-C FJ-LSMT-C6 5A 0-15A -05FA-LSND-C FJ-LSND-C6 5A 0-20A -05FA-LSNG-C FJ-LSNG-C6 5A 0-25A -05FA-LSNJ-C FJ-LSNJ-C6 5A 0-30A -05FA-LSNL-C FJ-LSNL-C6 5A 0-40A -05FA-LSNP-C FJ-LSNP-C6 5A 0-50A -05FA-LSNT-C FJ-LSNT-C6 5A 0-75A -05FA-LSPB-C FJ-LSPB-C6 5A 0-100A -05FA-LSPK-C FJ-LSPK-C6 5A 0-150A -05FA-LSPZ-C FJ-LSPZ-C6 5A 0-200A -05FA-LSRL-C FJ-LSRL-C6 5A 0-250A -05FA-LSRS-C FJ-LSRS-C6 5A 0-300A -05FA-LSRX-C FJ-LSRX-C6 5A 0-400A -05FA-LSSC-C FJ-LSSC-C6 5A 0-500A -05FA-LSSF-C FJ-LSSF-C6 Note: Additional meters with scales up to 8,000A available Insert 077 for 4 1 2" Case, 079 for 8 1 2" Case AC VOLTMETERS- RMS READING SELF CONTAINED 4 1 /2" Square Flange Standard Case Hi-Shock Case Rating Scale Catalog Number Catalog Number 150V 0-150V -05GA-PZPZ-C GJ-PZPZ-C6 250V 0-250V -05GA-RSRS-C GJ-RSRS-C6 300V 0-300V -05GA-RXRX-C GJ-RXRX-C6 500V 0-500V -05GA-SFSF-C GJ-SFSF-C6 600V 0-600V -05GA-SJSJ-C GJ-SJSJ-C6 750V 0-750V -05GA-SMSM-C GJ-SMSM-C6 Insert 077 for 4 1 2" Case, 079 for 8 1 2" Case AC VOLTMETERS - RMS READING TRANSFORMER RATED 150V 0-300V -05GA-PZRX-C GJ-PZRX-C6 150V 0-600V -05GA-PZSJ-C GJ-PZSJ-C6 150V 0-750V -05GA-PZSM-C GJ-PZSM-C6 150V V -05GA-PZUA-C GJ-PZUA-C6 150V V -05GA-PZUL-C GJ-PZUL-C6 150V V -05GA-PZUP-C GJ-PZUP-C6 150V V -05GA-PZUY-C GJ-PZUY-C6 150V 0-15 KV -05GA-PZWC-C GJA-PZWC-C6 150V 0-18 KV -05GA-PZWD-C GJ-PZWD-C6 150V 0-45 KV -05GA-PZWJ-C GJ-PZWJ-C6 250V 0-600V -05GA-RSSJ-C GJ-RSSJ-C6 Insert 077 for 4 1 2" Case, 079 for 8 1 2" Case 55 FREQUENCY METERS 120V SELF CONTAINED Standard Case Hi-Shock Case Center Frequency Accuracy Hz Scale Catalog Number Catalog Number 50 Hz ± Hz -41LA-PNAG-AG LJ-PNAG-AG 50 Hz ± Hz -41LA-PNAH-AH LJ-PNAH-AH 50 Hz ± Hz -41LA-PNAJ-AJ LJ-PNAJ-AJ 60 Hz ± Hz -41LA-PNAL-AL LJ-PNAL-AL 60 Hz ± Hz -41LA-PNAN-AN LJ-PNAN-AN 60 Hz ± Hz -41A-PNAO-AO LJ-PNAO-AO 60 Hz ± Hz -41A-PNAT-AT LJ-PNAT-AT Insert 077 for 4 1 2" Case, 079 for 8 1 2" Case

5 Crompton Switchboard Meters DC AMMETERS - SELF CONTAINED Standard Case Hi-Shock Case Rating Scale Catalog Number Catalog Number 200 ua ua -05AA-EAEA AJ-EAEA 300 ua ua -05AA-EEEE AA-EEEE 500 ua ua -05AA-EMEM AA-EMEM 800 ua ua -05AA-EWEW AA-EWEW 1 ma 0-1 ma -05AA-FAFA AA-FAFA 2 ma 0-2 ma -05AA-FGFG AA-FGFG 5 ma 0-5 ma -05AA-FXFX AA-FXFX 10 ma 0-10 ma -05AA-GZGZ AA-GZGZ 20 ma 0-20 ma -05AA-HFHF AA-HFHF 30 ma 0-30 ma -05AA-HMHM AA-HMHM 50 ma 0-50 ma -05AA-HYHY AA-HYHY 100 ma ma -05AA-JRJR AA-JRJR 200 ma ma -05AA-KAKA AA-KAKA 300 ma ma -05AA-KGKG AA-KGKG 500 ma ma -05AA-KMKM AA-KMKM 800 ma ma -05AA-KWKW AA-KWKW 1A 0-1A -05AA-LALA AA-LALA 5A 0-5A -05AA-LSLS AA-LSLS 10A 0-10A -05AA-MTMT AA-MTMT 15A 0-15A -05AA-NDND AA-NDND 20A 0-20A -05AA-NGNG AA-NGNG 30A 0-30A -05AA-NLNL AA-NLNL Insert 077 for 4 1 2" Case, 079 for 8 1 2" Case Standard Case Hi-Shock Case Rating Scale Catalog Number Catalog Number 50 mv 0-15A -05AA-EYND AJ-EYND 50 mv 0-20A -05AA-EYNG AJ-EYNG 50 mv 0-30A -05AA-EYNL AJ-EYNL 50 mv 0-40A -05AA-EYNP AJ-EYNP 50 mv 0-50A -05AA-EYNT AJ-EYNT 50 mv 0-75A -05AA-EYPB AJ-EYPB 50 mv 0-100A -05AA-EYPK AJ-EYPK 50 mv 0-150A -05AA-EYPZ AJ-EYPZ 50 mv 0-200A -05AA-EYRL AJ-EYRL 50 mv 0-300A -05AA-EYRX AJ-EYRX 50 mv 0-400A -05AA-EYSC AJ-EYSC 50 mv 0-500A -05AA-EYSF AJ-EYSF 50 mv 0-750A -05AA-EYSM AJ-EYSM 50 mv A -05AA-EYSS AJ-EYSS 50 mv A -05AA-EYSU AJ-EYSU 50 mv A -05AA-EYTC AJ-EYTC 50 mv A -05AA-EYTM AJ-EYTM 50 mv A -05AA-EYUA AJ-EYUA Insert DC AMMETERS - SHUNT RATED 077 for 4 1 2" Case, 079 for 8 1 2" Case 1/5 ma To Suit 4/20 ma To Suit 10/50 ma To Suit Insert MILLIAMMETERS = SUPPRESSED ZERO 077 for 4 1 2" Case, 079 for 8 1 2" Case Standard Case Hi-Shock Case Rating Scale Catalog Number Catalog Number 15V 0-15V -05VA-NDND VJ-NDND 30V 0-30V -05VA-NLNL VJ-NLNL 50V 0-50V -05VA-NTNT VJ-NTNT 75V 0-75V -05VA-PBPB VJ-PBPB 150V 0-150V -05VA-PZPZ VJ-PZPZ 300V 0-300V -05VA-RXRX VJ-RXRX 400V 0-400V -05VA-SCSC VJ-SCSC 500V 0-500V -05VA-SFSF VJ-SFSF 600V 0-600V -05VA-SJSJ VJ-SJSJ 750V 0-750V -05VA-SMSM VJ-SMSM 800V 0-800V -05VA-SNSN VJ-SNSN Insert DC VOLTMETERS (SENSITIVITY 1000 OHMS PER VOLTS) 077 for 4 1 2" Case, 079 for 8 1 2" Case Standard Case Hi-Shock Case Rating &Scale Catalog Number Catalog Number V -05NA-RXRX NJ-RXRX V -05NA-SJSJ NJ-SJSJ V -05NA-SSSS NJ-SSSS V -05NA-SUSU NJ-SUSU Insert DC VOLTMETERS - ZERO CENTER (2000 OHMS PER VOLT) 077 for 4 1 2" Case, 079 for 8 1 2" Case 56

6 Crompton Switchboard Meters Rugged taut bank construction 3 1 /2 digit LED display Wide selection of inputs Standard ANSI 4 1 /2" switchboard mounting 077-DI PHASE SHIFTING TRANSFORMERS For use with Wattmeters, when VAR measurement with external phase shifter is required Phase/ Amp/ Standard Case Hi-Shock Case Wire Volt Scale Catalog Number Catalog Number 3 / 3 120V To Suit -956-A-PR J-PR 3 / 4 120V To Suit -957-A-PR J-PR 3 / 4 69V To Suit -956-A-NZ J-NZ Use 855 for 4 1 2" or 8 3 4" Case AC POWER FACTOR METERS (BALANCED LOAD) Phase/ Amp/ Standard Case Hi-Shock Case Wire Volt Scale Catalog Number Catalog Number 1 / 2 5/ A-QQAD J-QQAD 1 / 2 5/ A-QSAD J-QSAD 3 / 3 or 4 5/ A-QQAD J-QQAD 3 / 3 or 4 5/ A-QRAD J-QRAD 3 / 3 or 4 5/ A-QSAD J-QSAD 3 / 3 or 4 5/ A-QTAD J-QTAD 3 / 3 or 4 5/ A-QVAD J-QVAD Use 077 for 4 1 2" Case and 079 for 8 1 2" Case UL Recognized and CSA Approved, 079 UL Recognized AC POWER FACTOR METERS (UNBALANCED LOAD) Phase/ Amp/ Standard Case Hi-Shock Case Wire Volt Scale Catalog Number Catalog Number 3 / 3 5/ TFUA-QQAD N/A 3 / 3 5/ TFUA-QQAD N/A AC POWER FACTOR METERS ROTATING IRON Phase/ Amp/ Standard Case Hi-Shock Case Wire Volt Scale Catalog Number Catalog Number 3 / 3 or 4 5/ A-QQAB J-QQAB 3 / 3 or 4 5/ A-QRAB J-QQAB 3 / 3 5/ A-QQAB J-QQAB 3 / 3 5/ A-QRAB J-QQAB Use 077 for 4 1 2" Standard Case and 079 for 8 3 4" Standard Case AC AMMETERS TRANSFORMER RATED (40/2000Hz) Digital accuracy ±0.1% ±1 counts, analog accuracy ±1%. Rating Scaling* Catalog No. 5A 0-20A 077-DIBA-LSNG-C6-** 5A 0-50A 077-DIBA-LSNT-C6-** 5A 0-100A 077-DIBA-LSPK-C6-** 5A 0-300A 077-DIBA-LSRX-C6-** 5A 0-400A 077-DIBA-LSSC-C6-** 5A 0-500A 077-DIBA-LSSF-C6-** 5A A 077-DIBA-LSTC-C6-** Direct reading AC Ammeters also available, 1A to 10A. AC VOLTMETERS TRANSFORMER RATED (40/2000HZ) Rating Scaling* Catalog No. 150V 0-300V 077-DIWA-PZRX-C6-** 150V 0-600V 077-DIWA-PZSJ-C6-** 150V 0-750V 077-DIWA-PZSM-C6-** 150V V 077-DIWA-PZUA-C6-** 150V V 077-DIWA-PZUP-C6-** Direct reading AC Voltmeters also available, 200mV to 600V. AC FREQUENCY METERS Self contained 110/130 Volt rating. Integral transducer Center Accuracy Scaling* Catalog No. 50Hz ± Hz 077-DZLA-PNAG-AG 55Hz ± Hz 077-DZLA-PNAJ-AJ 60Hz ± Hz 077-DZLA-PNAL-AL 60Hz ± Hz 077-DZLA-PNAN-AN 400Hz ± Hz 077-DZLA-PNBI-BI Direct reading AC Ammeters also available, 1A to 10A. DC VOLTMETERS - DIRECT READING Digital accuracy ±0.5% ±1 counts, analog accuracy ±1%. Rating Scaling* Catalog No. 200mV 0-200mV 077-DIVA-KAKA-** 1V 0-1V 077-DIVA-LALA-** 5V 0-5V 077-DIVA-LSLS-** 50V 0-50V 077-DIVA-NTNT-** 150V 0-150V 077-DIVA-PZPZ-** 300V 0-300V 077-DIVA-RXRX-** DC AMMETERS DIRECT READING Digital accuracy ±0.5% ±1 counts, analog accuracy ±1%. Rating Scaling* Catalog No. 1mA 0-1mA 077-DIAA-FAFA-** 10mA 0-10mA 077-DIAA-GZGZ-** 20mA 0-20mA 077-DIAA-HFHF-** 100mA 0-100mA 077-DIAA-JRJR-** 1A 0-1A 077-DIAA-LALA-** MU 12 Volts DC BD 24 Volts DC NR 48 Volts DC PR 120 Volts DC PS 125 Volts DC Z2 130 Volts DC ** POWER SUPPLY PO 115 Volts AC PQ 120 Volts AC RR 240 Volts AC Many standard ranges not shown. *Custom scales and custom ranges on request. 58

7 Yokogawa AC Motor Load and Frequency Meters Click Here to Order Online Horizon Line and Big Look Series Accuracy: ±2% of Full Scale, Iron Vane Type; ±3% of span for Frequency Meets ANSI C-39.1 Four Display Sizes: 1 1 2", 2 1 2", 3 1 2", and 4 1 2" Wide Selection of Frequency Ranges Severe Duty Meters Optional (2 1 2" to 4 1 2") to Meet UL1437 Surface-Mount or Window-Mount Models Model 251/255 Case Size 2 1 2" 3 1 2" 4 1 2" Size (H x W x D) 2.66" x 3.12" x 1.81" 3.32" x 3.89" x 1.83" 4.18" x 4.73" x 1.83" Barrel (cutout) 2.19" 2.72" 2.72" Window (cutout) 1.45" x 3.11" 1.84" x 3.88" 2.22" x 4.72" Model 250/254 Case Size 2 1 2" 3 1 2" 4 1 2" Size (H x W x D) 2.69" x 2.69" x 1.85" 3.50" x 3.50" x 1.85" 4.41" x 4.85" x 1.85" Barrel (cutout) 2.17" 2.72" 2.72" Scale Length 2.06" 2.88" 3.93" Iron Vane Type Accuracy 2%, 3% AC rectifier type (60 Hz sinewave) Repeatability ±0.5% Response Time 1.5 sec. Operating Temperature 0 40 C Storage Temperature 10 C 50 C Dielectric 2600V for 1 min. (0therwise per ANSI) except 1 1 2" size 1500V) AC Motors Load Indicators Rating Amps Scale Marking Type 2 1 2" 3 1 2" 4 1 2" % motor load current, Red band: LSPZ7AAA LSPZ7AAA LSPZ7AAA % motor load current LSPZ7AAB LSPZ7AAB LSPZ7AAB Grfdn band: 0-100, yellow: , red: % motor load current, Red band: LSPZ7AAJ LSPZ7AAJ LSPZ7AAJ % motor load current LSPZ7AAK LSPZ7AAK LSPZ7AAK Grfdn band: 0-100, yellow: , red: AC Frequency Meters, Self Contained, Accuracy ±3% of Span Voltage Input Center Frequency Scale (Hz) 120 VAC AGAG 350AGAG 450AGAG 120 VAC AJAJ 350AJAJ 450AJAJ 120 VAC ANAN 350ANAN 450ANAN 120 VAC BKBK 350BKBK 450BKBK 208 VAC GGGG 350GGGG 450GGGG 208 VAC GJGJ 350GJGJ 450GJGJ 208 VAC GNGN 350GNGN 450GNGN 208 VAC HKHK 350HKHK 450HKHK 240 VAC DGDG 350DGDG 450DGDG 240 VAC DJDJ 350DJDJ 450DJDJ 240 VAC DNDN 350DNDN 450DNDN 240 VAC EKEK 350EKEK 450EKEK Insert: for Big Look for Horizon Line 62

8 Crompton 3 1 2" Fiesta Panel Meters 016 Series Introduction A range of shortscale and longscale panel meters. Their rugged design will suit demanding environmental applications. Features Dust and Water Jet Protected to IP55 (IEC529) Withstands High Levels of Shock, Vibration, Dirt and Humidity The Contoured Window Gives an Exceptionally Wide Viewing Angle Complies with ANSI-C39 (IEC 51) UL Approval for Short Scale Ammeters, Voltmeters, Frequency Meters and Elapsed Time Meters on Selected Ranges. File Number E87815 Instruments Comply with BSEN Meets IEC414 (BS5458) Dielectric Test (2600V for 1 min) IP55 (NEMA 4) Options On request the following are available: Supplementary Pointer Non-Reflecting Window Heavily Damped Movement Panel Gasket Clamp Band Fixing Colored Internal Gasket AC Ammeter DC Voltmeter AC Voltmeter ELAPSED TIME METER AND FREQUENCY METER Voltage: Frequency: Burden: 100/125V, 200/250V or 480 VAC 50 Hz or 60 Hz 4 VA Maximum IRON VANE A.C. AMMETER & VOLTMETER Accuracy: Shortscale: Ammeters 2.0%; Longscale: 1.5% Ratings Ammeters: Shortscale: 1 to 80A Longscale: 1 to 20A Voltmeters: 10V to 600V Overload Ammeters: x1.2 for 2 hours 10 x for 5 seconds Voltmeters: x1.2 for 2 hours 2 x for 5 seconds Burden Ammeters: Shortscale: 0.5 VA Long scale: 1.5 VA Voltmeters: 4.5 VA Maximum MOVING COIL D.C. AMMETER & VOLTMETER Accuracy Class: Shortscale: 1.5 Longscale: 1.5 Rating Ammeters: 200 ma to 30A (100 ma Shortscale) Voltmeters: 50 mv to 600V Overload Ammeters: x1.2 for 2 hours x10 for 5 seconds Voltmeters: x1.2 for 2 hours x2 for 5 seconds Impedance: Voltmeters: 1000 ohms per volt nominal Operating: Storage: TEMPERATURE RANGE (ALL TYPES) -20 C to 65 C (-4 F to 149 F) -30 C to 70 C (-22 F to 158 F) 63

9 Crompton 3 1 2" Fiesta Panel Meters 016 Series A.C. Ammeters - True RMS Reading Shortscale Longscale Rating Scaling Catalog No. Catalog No. Self Contained 40/70Hz 5A 0-5A AA-LSLS AA-LSLS 10A 0-10A AA-MTMT AA-MTMT 15A 0-15A AA-NDND AA-NDND 20A 0-20A AA-NGNG AA-NGNG 30A 0-30A AA-NLNL AA-NLNL 5A Transformer Rated AA-LS** AA-LS** A.C. Voltmeters - True RMS Reading 150V 0-150V VA-PZPZ VA-PZPZ 300V 0-300V VA-RXRX VA-RXRX 600V 0-600V VA-SJSJ VA-SJSJ 150V Transformer Rated VA-PZ** VA-PZ** D.C. Ammeters 0-50 mv To Suit Requirements AA-EC** AA-EC** 0-1 ma To Suit Requirements AA-FA** AA-FA** 0-5 ma To Suit Requirements AA-FX** AA-FX** 0-10 ma To Suit Requirements AA-HA** AA-HA** 0-20 ma To Suit Requirements AA-HF** AA-HF** Milliammeters - Suppressed Zero no zero set unless specified 4/20 ma To Suit Requirements RA-HG** RA-HG** D.C. Voltmeters (Sensitivity 1000Ω/Volt) 0-15V 0-15V VA-NDND VA-NDND 0-30V 0-30V VA-NLNL VA-NLNL 0-50V 0-50V VA-NTNT VA-NTNT 0-150V 0-150V VA-PZPZ VA-PZPZ 0-300V 0-300V VA-RXRX VA-RXRX 0-600V 0-600V VA-SJSJ VA-SJSJ Frequency Meters, 120V* (Self Contained) Center Standard Case Freq Hz Accuracy Scale Catalog No. 50 Hz Hz SA-PNAG-AG 50 Hz Hz SA-PNAJ-AJ 60 Hz Hz SA-PNAN-AN 60 Hz Hz SA-PNAO-AO 400 Hz Hz SA-PNBI-BI *Alternate voltage rating V use code RN instead of PN *Alternate voltage rating V use code SE instead of PN Elapsed Time Meters hours, non reset Voltage Frequency Standard Case Range Hz Scale Catalog No. 110/130V 50 Hz A-PNZH-C5 200/250V 50 Hz A-RNZH-C5 480V 50 Hz A-SEZH-C5 110/130V 60 Hz A-PNZH-C6 200/250V 60 Hz A-RNZH-C6 480V 60 Hz A-SEZH-C6 UL Recognized ** Specify Scale Elapsed Time Meter Frequency Meter 64

10 Simpson Frequency Meters Four Different Models 2 1 2", 3 1 2" and 4 1 2" sizes Simpsons frequency meters are ideal for monitoring line frequency. They are used wherever fast, precise monitoring of complex circuits is essential. Segmental scale meters present a selected frequency range across the entire dial face in linear fashion, where other meters are squeezed into a quarter of an inch of space. Wide-Vue Century Accuracy: 3% Suspension: Pivot and Jewel Movement: Small Core Magnet Rectangular Round Model: 1287, 2 1 2" WIDEVUE Model: 1387, 3 1 2" WIDEVUE Model: 1389, 4 1 2" WIDEVUE Cat # Frequency Voltage Cat # Frequency Voltage Cat # Frequency Voltage HZ 120V HZ 120V HZ 120V HZ 240V HZ 240V HZ 240V HZ 120V HZ 120V HZ 120V HZ 240V HZ 240V HZ 240V HZ 120V HZ 120V HZ 120V HZ 240V HZ 240V HZ 240V Model: 2182, 2 1 2" CENTURY Model: 2183, 3 1 2" CENTURY Model: 2184, 4 1 2" CENTURY Cat # Frequency Voltage Cat # Frequency Voltage Cat # Frequency Voltage HZ 120V HZ 120V HZ 120V HZ 240V HZ 240V HZ 240V HZ 120V HZ 120V HZ 120V HZ 240V HZ 240V HZ 240V HZ 120V HZ 120V HZ 120V HZ 240V HZ 240V HZ 240V Model: 187, 2 1 2" RECTANGULAR Model: 87, 3 1 2" RECTANGULAR Model: 89, 4 1 2" RECTANGULAR Cat # Frequency Voltage Cat # Frequency Voltage Cat # Frequency Voltage HZ 120V HZ 120V HZ 120V HZ 240V HZ 240V HZ 240V HZ 120V HZ 120V HZ 120V HZ 240V HZ 240V HZ 240V HZ 120V HZ 120V HZ 120V HZ 240V HZ 240V HZ 240V Model: 185, 2 1 2" ROUND Model: 85, 3 1 2" ROUND Cat # Frequency Voltage Cat # Frequency Voltage HZ 120V HZ 120V HZ 240V HZ 240V HZ 120V HZ 120V HZ 240V HZ 240V HZ 120V HZ 120V HZ 240V HZ 240V 67

11 69b Jewell AC Current and Voltage Meters Modutec S & W Series Five Display Sizes: 1½", 2½", 3½", 4½" and 5½" Shielded Taut-Band Movement Surface-Mount or Window-Mount Models S Series W Series These meters are available in both moving coil (rectifier type) and iron vane versions. The iron vane construction is relatively insensitive to input distortion. The rectifier type is less affected by frequency variations. Use Ordering Code Guide to complete Part #. Insert Size Code in box 1 and Model Code in box 2. AC Voltmeters Self-contained, rectifier type, 900Ω/V AVV AVV AVV AVV AVV AVV AVV AVV AVV AVV AVV-600 AC Voltmeters Transformer rated, 0-150V, rectifier type AVV AVV AVV-3000 AC Voltmeters Iron vane: self-contained, 60Hz nominal AVC-003 ** AVC-005 ** AVC-010 ** AVC-015 ** AVC-030 ** AVC-050 ** AVC-100 ** AVC-150 ** AVC-300 ** AVC-500 ** AVC-600 ** AC Voltmeters Iron vane: transformer rated, 0-150V, 60Hz AVCX-600 ** AVCX-750 ** AVCX-1500 ** AVCX-3000 ** Model W Series Case Size 1½" 2½" 3½" 4½" 5½" Size (H x W x D) 1.77 x 2.26 x 1.83" 2.29 x 3.01 x 2.10" 2.90 x 3.73 x 2.12" 4.06 x 5.18 x 2.17" 4.60 x 5.97 x 2.17" Window (cutout) x 2.15" 1.27 x 2.90" x 3.61" x 5.02" 2.59 x 5.78" Model S Series Case Size 1½" 2½" 3½" 4½" 5½" Size (H x W x D) 1.75 x 2.24 x 1.55" 2.27 x 2.99 x 1.80" 2.87 x 3.70 x 1.80" 3.96 x 5.10 x 1.80" 4.48 x 5.85 x 1.80" Barrel (cutout) 1.55" 2.22" 2.82" 2.82" 2.82" All Models: Scale Length (Rect/Iron) 1.75" 2.41"/2.15" 3.0"/2.7" 4.22"/3.8" 5.12"/--- Accuracy ±2% iron vane type, ±3% AC rectifier type (60 Hz sinewave) Repeatability ±2% iron vane, ±0.5% rectifier type Response Time 1.5 sec. (except 3 sec. for <50μA full scale) OPTIONS (WHERE APPLICABLE) Custom Scaling Mirror Scale High Torque Movement Color Bands Illumination Custom Artwork Sealed Case Bezel Mount Kit Also Available: VU Meters & Elapsed Time Meters AC Milliammeters Self-contained, rectifier type Ω 1 2 -AMA AMA AMA AMA AMA AMA AMA-200 * AMA-500 * AC Milliammeters Iron vane: Self-contained, 60Hz nominal input (50-400Hz range) AMC-010 ** AMC-025 ** AMC-050 ** AMC-100 ** AMC-250 ** AMC-500 ** AC Ammeters Self-contained, rectifier type AAA-001 * AAA-0015 * AAA-002 * AAA-003 * AAA-005 * AAA-010 * AAA-015 * AAA-020 * AAA-025 * AAA-030 * AAA-050 * AC Ammeters Iron vane: Self-contained, 60Hz nominal input (50-400Hz range) AAC-001 ** AAC-0015 ** AAC-002 ** AAC-003 ** AAC-005 ** AAC-010 ** AAC-015 ** AAC-020 ** AAC-025 ** AAC-030 ** AAC-050 ** ORDERING CODE GUIDE AC Ammeters Transformer rated, 0-5A, rectifier type AAAX-060 * AAAX-075 * AAAX-100 * AAAX-150 * AAAX-200 * AAAX-300 * AAAX-400 * AAAX-500 * AAAX-600 * AAAX-800 * AAAX-1000 * AAAX-1500 * AAAX-2000 * AC Ammeters Iron vane: Transformer rated, 0-5A, 60Hz nominal input (50-400Hz range) AACX-060 ** AACX-075 ** AACX-100 ** AACX-150 ** AACX-200 ** AACX-300 ** AACX-500 ** AACX-600 ** AACX-800 ** AACX-1000 ** AACX-1500 ** AACX-2000 ** Frequency Meters Pointer Type Electronic Hz 120V 1 2 -FRQ-55/ ** FRQ-50/ ** FRQ-60/ ** FRQ-400/ ** FRQ-50/ ** FRQ-60/ ** *not available in 1½" size **not available in 1½" or 5½" sizes 1 2 Insert Size Code: CASE SIZE 1 1½" 2 2½" 3 3½" 4 4½" 5 5½" Insert Model Code: STYLE S Surface Mount W Window Mount

12 Jewell AC Current and Voltage Meters Modutec PB Series Four Display Sizes: 1½", 2½", 3½", and 4½" Shielded Taut-Band Movement Large, Easy to Read Scale Model PB Series Case Size 1½" 2½" 3½" 4½" Size (H x W x D) 1.75 x 1.75 x 1.39" 2.70 x 2.70 x 1.77" 3.50 x 3.50 x 1.77" 4.41 x 4.85 x 1.84" Barrel (cutout) 1.53" 2.20" 2.75" 2.79" Scale Length 1.26" 2.10" 2.90" 4.00" Accuracy Repeatability Response Time ±2% iron vane type, ±3% AC rectifier type (60 Hz sinewave) ±2% iron vane, ±0.5% rectifier type 1.5 sec. (except 3 sec. for <50μA full scale) The PB series industrial panel board meters meet or exceed the requirements of ANSI C39.1. The mounting stud configuration complies with ANSI standards. Number of studs varies by size: 1½" meters - 2 studs; 2½" & 3½" meters - 3 studs; 4½" meters - 4 studs. PB Series These meters are available in both moving coil (rectifier type) and iron vane versions. The iron vane construction is relatively insensitive to input distortion. The rectifier type is less affected by frequency variations. Use Ordering Code Guide to complete Part #. Insert Size Code in box 1. AC Voltmeters Self-contained, rectifier type, 900Ω/V PB-AVV PB-AVV PB-AVV PB-AVV PB-AVV PB-AVV PB-AVV PB-AVV PB-AVV PB-AVV PB-AVV-600 AC Voltmeters Transformer rated, 0-150V, rectifier type PB-AVVX PB-AVVX PB-AVVX-3000 AC Voltmeters Iron vane: self-contained, 60Hz nominal PB-AVC-003 * PB-AVC-005 * PB-AVC-010 * PB-AVC-015 * PB-AVC-030 * PB-AVC-050 * PB-AVC-100 * PB-AVC-150 * PB-AVC-300 * PB-AVC-500 * PB-AVC-600 * AC Voltmeters Iron vane: transformer rated, 0-150V, 60Hz PB-AVCX-600 * PB-AVCX-750 * PB-AVCX-1500 * PB-AVCX-3000 * OPTIONS (WHERE APPLICABLE) Custom Scaling Mirror Scale High Torque Movement Color Bands Custom Artwork Heavy Damping Also Available: VU Meters & Elapsed Time Meters AC Milliammeters Self-contained, rectifier type Ω 1 PB-AMA PB-AMA PB-AMA PB-AMA PB-AMA PB-AMA PB-AMA PB-AMA-500 AC Milliammeters Iron vane: Self-contained, 60Hz nominal input (50-400Hz range) PB-AMC-010 * PB-AMC-025 * PB-AMC-050 * PB-AMC-100 * PB-AMA-250 * PB-AMC-500 * AC Ammeters Self-contained, rectifier type PB-AAA-001 * PB-AAA-0015 * PB-AAA-002 * PB-AAA-003 * PB-AAA-005 * PB-AAA-010 * PB-AAA-015 * PB-AAA-020 * PB-AAA-025 * PB-AAA-030 * PB-AAA-050 * AC Ammeters Iron vane: Self-contained, 60Hz nominal input (50-400Hz range) PB-AAC-001 * PB-AAC-0015 * PB-AAC-002 * PB-AAC-003 * PB-AAC-005 * PB-AAC-010 * PB-AAC-015 * PB-AAC-020 * PB-AAC-025 * PB-AAC-030 * PB-AAC-050 * 1 ORDERING CODE GUIDE Insert Size Code: CASE SIZE 1 1½" 2 2½" 3 3½" 4 4½" AC Ammeters Transformer rated, 0-5A, rectifier type PB-AAAX PB-AAAX PB-AAAX PB-AAAX PB-AAAX PB-AAAX PB-AAAX PB-AAAX PB-AAAX PB-AAAX PB-AAAX PB-AAAX PB-AAAX-2000 AC Ammeters Iron vane: Transformer rated, 0-5A, 60Hz nominal input (50-400Hz range) PB-AACX-060 * PB-AACX-075 * PB-AACX-100 * PB-AACX-150 * PB-AACX-200 * PB-AACX-300 * PB-AACX-500 * PB-AACX-600 * PB-AACX-800 * PB-AACX-1000 * PB-AACX-1500 * PB-AACX-2000 * Frequency Meters Pointer Type Electronic Hz 120V 1 PB-55/ * PB-50/ * PB-60/ * PB-400/ * PB-50/ * PB-60/ * *not available in 1½" size 69d

ANSI Switchboard Meters

ANSI Switchboard Meters ANSI Switchboard Meters High quality range of switchboard instruments with Class 1 accuracy and which complies with American ANSI-C39.1 (1981) specifications. Available in 4 1 /2" case size, the rugged

More information

Crompton Instruments. ANSI Switchboard Meters

Crompton Instruments. ANSI Switchboard Meters Crompton Instruments ANSI Switchboard Meters www.crompton-instruments.com Crompton Instruments ANSI SWITCHBOARD METERS An extensive range of analog and digital/analog meters in the 4½" ANSI case style.

More information

070 Series ANSI Switchboard Meters

070 Series ANSI Switchboard Meters Approvals UL Approved File No: E87815 This high quality range of Switchboard instruments complies with the American specification ANSI-C39.1 (1981) accuracy class 1. Available in two case sizes, their

More information

LED Digital Analog Combination

LED Digital Analog Combination Crompton Instruments model 007-DI features a combination of the traditional 250 4 1 2" switchboard indicator with the trend indication plus the benefits of wide angle LED visibility. This rugged shock

More information

Weschler Analog Edgewise and Panel Meters

Weschler Analog Edgewise and Panel Meters Weschler Analog Edgewise and Panel Meters Type 252 edgewise instruments were designed specifically for the nuclear power industry. Their ruggedness and reliability make them an excellent choice for any

More information

International Instruments Edgewise Panel Meters

International Instruments Edgewise Panel Meters International Instruments Edgewise Panel Meters 3 1 /2" and 6" Switchboard Meters Accuracy: ±1.5% (1151/1251) Single (1146/1151) or Dual Indicators (1246/1251) Rugged Construction Flush Stacking EMI Shielded

More information

75a. Hoyt VU Meters. Industry Standard for Volume Level Measurements Sizes from 1.5" to 4.5" Choice of Styles & Mounting Made in U.S.A.

75a. Hoyt VU Meters. Industry Standard for Volume Level Measurements Sizes from 1.5 to 4.5 Choice of Styles & Mounting Made in U.S.A. Hoyt VU Meters Industry Standard for Volume Level Measurements Sizes from 1.5" to 4.5" Choice of Styles & Mounting Made in U.S.A. The VU meter is the standard level indicator for audio frequency transmission

More information

Crompton AC Overload Ammeters. Crompton 4-IN-1 Panel Meters NEW. DIN Panel Meters. Fiesta 3 1 /2" Panel Meter SPECIFICATIONS/ORDERING INFORMATION

Crompton AC Overload Ammeters. Crompton 4-IN-1 Panel Meters NEW. DIN Panel Meters. Fiesta 3 1 /2 Panel Meter SPECIFICATIONS/ORDERING INFORMATION Crompton AC Overload Ammeters X6 Overload Scaling for Motor Start Duty True RMS Reading, Self Contained 50/60Hz 3 1 /2", 3 /16 DIN & 1 /4 DIN sizes Fiesta Fiesta 3 1 /2" Panel Meter SPECIFICATIONS/ Accuracy

More information

YOKOGAWA Supplies A Complete Line of Precise Panel Meters... RoHS compliant

YOKOGAWA Supplies A Complete Line of Precise Panel Meters... RoHS compliant YOKOGAWA Supplies A Complete Line of Precise Panel Meters... RoHS compliant Elapsed Time Meters Devices will match the frequency of AC power systems. Six-digit counters record hours, tenths of hours, minutes

More information

AC Wattmeters and VArmeters

AC Wattmeters and VArmeters AC Wattmeters and VArmeters The Crompton Instruments Switchboard series of AC Wattmeters and VArmeters incorporate a DC moving coil, pivot and jewel indicator with a micro-circuit watt transducer PCB to

More information

ANSI Switchboard Meters

ANSI Switchboard Meters ANSI Switchboard Meters High quality range of switchboard instruments with Class 1 accuracy and which complies with American ANSI-C39.1 (1981) specifications. Available in 4 1 /2" case size, the rugged

More information

Century Style Analog Panel Meters

Century Style Analog Panel Meters UL Recognized File # E91015 Except for the Wattmeters and Frequency Meters Glass window for optimum viewing Rugged black plastic case Black knife-edge pointer for precision reading The Specifications &

More information

Wide-Vue Analog Panel Meters

Wide-Vue Analog Panel Meters UL Recognized - File # E91015 Except for the Wattmeters & Frequency Meters Clear acrylic window for wide viewing area Rugged black plastic case Black spade pointer for easy distant reading Optional: Behind-panel

More information

PLATINUM SERIES SWITCHBOARD METERS

PLATINUM SERIES SWITCHBOARD METERS PLATINUM SERIES SWITCHBOARD METERS www.sifamtinsley.co.uk DATASHEET E471457 Multifunction Meters Transducers & Isolators PLATINUM SERIES SWITCHBOARD METERS Temperature Controllers Converters & Recorders

More information

Wide-Vue Analog Panel Meters

Wide-Vue Analog Panel Meters UL Recognized - File # E91015 Except for the Wattmeters & Frequency Meters Clear acrylic window for wide viewing area Rugged black plastic case Black spade pointer for easy distant reading Optional: Behind-panel

More information

Key to AB/DB Switchboard Numbering System (See Notes)

Key to AB/DB Switchboard Numbering System (See Notes) Key to AB/DB Switchboard Numbering System (See Notes) 103 01 1 XX XX 7* XXX Digits 1, 2, & 3 Type 101-TB-AB/DB14 102-P&J AB/DB17 103-TB-AB/DB40 106-P&J-AB40 Synch. 120-P&J-AB16 Synch. 121-TB-AB/DB16 123-D-V

More information

Smart Look Series Meter

Smart Look Series Meter File No. E471457 Technical Data Sheet Smart Look Series Meter 1/2 The moving iron & moving coil panel meters sizes 2 " 1/2, 3 " are housed in a moulded polycarbonate cases which are suitable for the measurement

More information

Jewell 212, 312 and 412 VISTA Series Analog Panel Meter Series BEST IN CLASS

Jewell 212, 312 and 412 VISTA Series Analog Panel Meter Series BEST IN CLASS Application: The VISTA range of analog panel meters offers accurate measurement and indication of most electrical and electronic parameters in industry as per industrial standard case size. Available Models:

More information

M Series 140.D Data Sheet. Two-Point Controller with Moving-Iron or Moving-Coil Movement 90 Dial RW 96 RP 96

M Series 140.D Data Sheet. Two-Point Controller with Moving-Iron or Moving-Coil Movement 90 Dial RW 96 RP 96 Data Sheet M Series 140.D.101.06 RW 96 RP 96 Two-Point Controller with Moving-Iron or Moving-Coil Movement 90 Dial Application The two point controllers RW/RP 96 (M series) with one or two setpoints provide

More information

DIN Rail Mounting Bracket

DIN Rail Mounting Bracket DIN Rail Mounting Bracket Fits Simpson Hawk 3, Falcon and Counters Fits Standard Din Rail C 1 4.30 2.55 3.85 Din Rail Adapter 44 Enclosure: Attachment Clips: Stiffeners: Installed depth: UL94V-0 Rated

More information

Analogue Instruments. DIN Panel Meters. Benefits Low cost Local indication Ease of installation Minimal training Low maintenance Reasonable accuracy

Analogue Instruments. DIN Panel Meters. Benefits Low cost Local indication Ease of installation Minimal training Low maintenance Reasonable accuracy Analogue Instruments High quality analogue instruments designed to measure an extensive range of electrical and electronic parameters. This comprehensive range offers DIN instruments, ANSI switchboard

More information

M Series 010.D Data Sheet. Analog Meters with Moving-Coil Movement, 90 Dial PSQ 48 PQ 72 RS PQ 96 RS PQ 144 RS

M Series 010.D Data Sheet. Analog Meters with Moving-Coil Movement, 90 Dial PSQ 48 PQ 72 RS PQ 96 RS PQ 144 RS Data Sheet M Series 010.D.101.11 Analog Meters with Moving-Coil Movement, 90 Dial PSQ 48 PQ 72 RS PQ 96 RS PQ 144 RS Application The moving - coil panel meters PSQ 48 in a housing of moulded thermoplastic

More information

ntents Meter Product Line-up Usage Precautions View Scale Forms and Divisions Standard Specifications Key to Meters Numbering System DC Ammeters

ntents Meter Product Line-up Usage Precautions View Scale Forms and Divisions Standard Specifications Key to Meters Numbering System DC Ammeters H Contents Meter Product Line-up Usage Precautions View Scale Forms and Divisions Standard Specifications Key to Meters Numbering System DC Ammeters DC Voltmeters Suppressed Meters (DC Ammeters & Voltmeters)

More information

240 Series DIN Panel Meters

240 Series DIN Panel Meters An extensive range of 48, 72, 96 and 144mm DIN style panel meters offering measurement of all electrical and electronic parameters. Meters are shock resistant and vibration proof and supplied with terminal

More information

DIN Panel Meters Long Scale

DIN Panel Meters Long Scale DIN Panel Meters Long Scale A range of 72mm and 96mm DIN style panel meters measuring all electrical parameters and featuring moving coil movements. All meters incorporate slide-in dials and terminal covers

More information

212, 312 & 412 Vista Series Analog Panel Meter

212, 312 & 412 Vista Series Analog Panel Meter 212, 312 & 412 Vista Series Analog Panel Meter Application The VISTA range of analog panel meters offers accurate measurement and indication of most electrical and electronic parameters in industry as

More information

Technical Data Sheet Sigma Series DS Meter

Technical Data Sheet Sigma Series DS Meter Technical Data Sheet Sigma Series DS Meter The moving coil panel meters, DS 48/72/96/144 housed in moulded polycarbonate cases are suitable for the measurement of DC currents and voltages. These instruments

More information

212, 312 & 412 Vista Series Analog Panel Meter

212, 312 & 412 Vista Series Analog Panel Meter C R LISTED File No. E471457 Analog Panel Meter Application The VISTA range of analog panel meters offers accurate measurement and indication of most electrical and electronic parameters in industry as

More information

Price List Effective from :

Price List Effective from : List Effective from :- 01-04-2018 INDICATING MOVING IRON, MOVING COIL VOLTMETER & AMMETER ME BRAND Moving Iron Instruments are generally used for measuring A.C. Voltage and currents. These are Repulsion

More information

Panel Meters and Accessories Digital Panel Meter

Panel Meters and Accessories Digital Panel Meter Digital Panel Meter - SE - - X 2 3 4 5 6. Product code 2. Input Signal Mode 48--48X48 72--72X72 96--96X96 94--96X48 3. Function Mode I--current U--voltage P--active power Q--reactive power H--power factor

More information

Portable Instruments. Bulletin 2000-E

Portable Instruments. Bulletin 2000-E Portable Instruments Bulletin 2000-E Usage Precautions Warning: Indicates usage precautions that must be read to ensure the safety of users and the equipment. Safety Instructions for Portable Instruments

More information

PANEL METER CATALOG

PANEL METER CATALOG PANEL METER CATALOG 18002583652 WWW.HOYTMETER.COM Case Style & Construction 1000 Series 41/2 21/2 31/2 Page 9 Phenolic and Glass Meters 4000 Series 21/2 31/2 41/2 Page 16 1025/26 1037/38 1045/46 Clear

More information

SIGMA SERIES DE METER

SIGMA SERIES DE METER SIGMA SERIES DE METER Analogue Meters www.sifamtinsley.co.uk DATASHEET Issue 1.0 Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current

More information

Distributed by: DIN METER SERIES. Yokogawa Corporation of America WESCHLER INSTRUMENTS

Distributed by: DIN METER SERIES. Yokogawa Corporation of America WESCHLER INSTRUMENTS Distributed by: DIN METER SERIES Yokogawa Corporation of America WESCHLER INSTRUMENTS 800-903-9870 440-378-6580 www.weschler.com info@weschler.com Contents Meter Product Line-up Usage Precautions Specifications

More information

SECTION INDEX. Whether the need is for a simple voltmeter or a complex monitoring system, look to Blue Sea Systems for a solution.

SECTION INDEX. Whether the need is for a simple voltmeter or a complex monitoring system, look to Blue Sea Systems for a solution. 88 Metering Solution-Oriented Metering Keeping track of onboard systems is critical to safety and peace of mind. Running low on fuel or not knowing about a failing battery can lead to dangerous situations.

More information

www. ElectricalPartManuals. com INS T R U c.t I 0 N S Westinghouse OPER.ATION MAINTENANCE INSTALLATION SWITCHBOARD INSTRUMENTS SIX-INCH CLASSIFICATION

www. ElectricalPartManuals. com INS T R U c.t I 0 N S Westinghouse OPER.ATION MAINTENANCE INSTALLATION SWITCHBOARD INSTRUMENTS SIX-INCH CLASSIFICATION Cases GENERAL INSTALLATION Westinghouse I.L. 43-250-F OPER.ATION MAINTENANCE INS T R U c.t I 0 N S The first letter in type designates the form of case used. U =Rect. Proj. Base M't'd 5'/z" x 5'/z". K

More information

Power System Measurements. Made in U.S.A. Power Series Plus. Digital Switchboard Meters.

Power System Measurements. Made in U.S.A. Power Series Plus. Digital Switchboard Meters. Power System Measurements Made in U.S.A. 800-903-9870 info@weschler.com www.weschler.com A Commitment to Customer Service & Support Weschler Instruments has acquired the line from Yokogawa s Meters & Instruments

More information

Meters Product Selection Guide

Meters Product Selection Guide Meters Product Selection Guide Bulletin 22-E C O N T E N T S P 4 Product Line-up P 6 Portable Precision Instruments P 12 Switchboard Instruments 21A Series P 16 Panel Meters CLEAR LINE Series P 2 Panel

More information

Technical Data Sheet Sigma Series DG Meter

Technical Data Sheet Sigma Series DG Meter Technical Data Sheet The moving coil, recti er meters, DG 48/72/96 housed in moulded polycarbonate cases are suitable for the measurement of AC currents and voltages. Special Features Less VA burden. Linear

More information

POWER FACTOR METERS LF 72 / LF 96 ANALOGUE METERS

POWER FACTOR METERS LF 72 / LF 96 ANALOGUE METERS POWER FACTOR METERS - LF 72 / LF 96 Analogue Meters www.sifamtinsley.co.uk DATASHEET Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current

More information

Technical Data Sheet Sigma Series DE Meter

Technical Data Sheet Sigma Series DE Meter Technical Data Sheet Sigma Series DE Meter The moving iron panel meters, DE 48/72/96/144 are housed in a moulded polycarbonate cases which are suitable for the measurement of AC currents for frequency

More information

Power System Measurements. Made in U.S.A. Power SeriesP lus. Digital Switchboard Meters.

Power System Measurements. Made in U.S.A. Power SeriesP lus. Digital Switchboard Meters. Power System Measurements Made in U.S.A. Power SeriesP lus 800-557-0064 sales@weschler.com www.weschler.com The POWER SERIES Plus digital switchboard meter was developed by Yokogawa Corporation of America

More information

POWER DIGITAL SWITCHBOARD METERS

POWER DIGITAL SWITCHBOARD METERS POWER S POWER SERIES Plus Other Catalogs Available... Power Transducers Current & Potential Transformers Yokogawa Juxta Power Transducers (models 2469, 2489) are UL recognized and enclosed in a rugged

More information

Standard Program Technical Description

Standard Program Technical Description Standard Program Technical Technical Square Panel Meters Square panel meters per DIN 43700 with quadrant scale, dull black or dull gray (RAL 7037) bezel per DIN 43718.. Interchangeable Scales Meter s scale

More information

Meter Product Line-up. Usage Precautions. Standard Specifications. Key to Numbering System. DC Ammeters. DC Voltmeters

Meter Product Line-up. Usage Precautions. Standard Specifications. Key to Numbering System. DC Ammeters. DC Voltmeters Bulletin 274A-E 2 Contents Meter Product Line-up Usage Precautions Standard Specifications Key to Numbering System DC Ammeters DC Voltmeters Suppressed Meters (DC Ammeters and Voltmeters) AC Ammeters (Mean

More information

Test&Measurement. Power Series Plus. Digital Switchboard Meters

Test&Measurement. Power Series Plus. Digital Switchboard Meters Test&Measurement Power Series Plus Precision Making tmi.yokogawa.com SWITCHBOARD INSTRUMENTS... 1 Power Series Plus Other Catalogs Available... Power Transducers Yokogawa Juxta Power Transducers (models

More information

Current Switches and Transducers

Current Switches and Transducers Current Switches and Transducers Models CT-800,-805, -810, -815, -820, -825, -830 and CU-850, -855, -860, -865, -870, -875, -880, and -885 Easy to install... Small size, built-in mounting flanges, and

More information

Square Shape Instrument - PK Series

Square Shape Instrument - PK Series Square Shape Instrument - PK Series PK-series is a square type meter. 4 difference degree type for this square PK-series:120mm, 100mm, 80mm & 60mm. Panel cut dimension is conformity with JIS C 1103. PK

More information

POWER SERIES DIGITAL SWITCHBOARD METERS. Plus

POWER SERIES DIGITAL SWITCHBOARD METERS. Plus POWER SERIES S Plus POWER SERIES Plus Other Catalogs Available... Power Transducers Current & Potential Transformers Yokogawa Juxta Power Transducers (models 2469, 2489) are UL recognized and enclosed

More information

MX4X-6XXX Series MX4X-7XXX Series. Selection Guide. Applications. DuraDrive Series Actuators and Accessories

MX4X-6XXX Series MX4X-7XXX Series. Selection Guide. Applications. DuraDrive Series Actuators and Accessories MX4X-6XXX Series MX4X-7XXX Series Selection Guide DuraDrive Series Actuators and Accessories Applications DuraDrive Direct Coupled Actuators are designed to accept two-position, floating, or proportional

More information

Data Sheet. Analogue Meters With Moving - Iron Movement - DE DE 48 DE 72 DE 96 DE 144. Analogue Meters with. Moving - Iron Movement

Data Sheet. Analogue Meters With Moving - Iron Movement - DE DE 48 DE 72 DE 96 DE 144. Analogue Meters with. Moving - Iron Movement Analogue Meters With Moving - Iron Movement - DE DE 48 DE 72 DE 96 DE 144 Data Sheet Analogue Meters with Moving - Iron Movement Tel. +91 253 22216, 22222 Fax +91 253 235164 E-mail India - marketing@rishabh.co.in

More information

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................

More information

Product Guide AC Voltage Control Devices. Guide Guide. Popular Variable Transformers and AC Power Supplies.

Product Guide AC Voltage Control Devices. Guide Guide. Popular Variable Transformers and AC Power Supplies. Popular Variable Transformers and AC Power Supplies Product Guide AC Voltage Control Devices Guide Guide Your Tailored Power Solutions Provider TM Staco Energy Products Co. has been a leading manufacturer

More information

ELECTRICAL PANELS. Chap.

ELECTRICAL PANELS. Chap. ELECTRICAL PANELS 360 Panel System Electrical Panels 360 Panel System Modular Panels DC Electric Panels AC Electric Panels AC/DC Electric Panels Aber Marine Panels IP 67 Watertight Panels Rotary Switch

More information

Control Relays Overview

Control Relays Overview Control Relays Overview DESIGN FEATURES Among the advances Agastat Control Relays offer over existing designs is a unique contact operating mechanism. An articulated arm assembly amplifies the movement

More information

SURE-TRIP OEM RELACEMENT TRIP UNIT

SURE-TRIP OEM RELACEMENT TRIP UNIT RMS CURRENT MEASUREMENT with SURE-TRIP OEM RELACEMENT TRIP UNIT Update Circuit Breaker Solid State Controls with SURE-TRIP LOGIC The SURE-TRIP Solid State Tripping Systems Have Been Designed, Tested And

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS Page 1 of 2 Ref: IW012346 Rev 4 July 03 Indicators Saxon & Fiesta Series Products Covered 012-**, 013-**, 014-** & 016-** Installation The product should be panel mounted using the mounting kit provided.

More information

2. Analog measurement of Electrical Quantities

2. Analog measurement of Electrical Quantities 2.1. Classification of Analog Instruments Definition and concept of Measurement The analog instruments can be classified on the basis of various parameters. Analog Instruments On the basis of measuring

More information

SURE TRIP RETRO KITS

SURE TRIP RETRO KITS RMS CURRENT MEASUREMENT with SURE TRIP RETRO KITS Circuit Breaker Solid State Controls with SURE TRIP LOGIC The Sure Trip Solid State Tripping Systems Have Been Designed, Tested And Produced To all Applicable

More information

FSM SERIES. Brushless Servo Motor Manual

FSM SERIES. Brushless Servo Motor Manual Return or Disposal of Motors Please contact the source that supplied the motor should warranty or non-warranty repair be required. All returned products require a Return Material Authorization (RMA) number

More information

AC Rectifiers for use with Armature Actuated Brakes. Product Overview. Full Wave. Half Wave. Combination Full and Half Wave. TOR-AC Full and Half Wave

AC Rectifiers for use with Armature Actuated Brakes. Product Overview. Full Wave. Half Wave. Combination Full and Half Wave. TOR-AC Full and Half Wave Rectifiers for use with Armature Actuated Brakes Product Overview NOTE: For brake response times with and without rectifiers see page 94. Full Wave A rectifier in which both positive and negative half-cycles

More information

HD110C Heavy-Duty Digital Multimeter

HD110C Heavy-Duty Digital Multimeter HD110C Heavy-Duty Digital Multimeter Key features: Measures 1500 VDC CAT IV 1000 V IP67 Rated Magne-Grip holster with magnetic hanging strap No hassle warranty No waiting. No shipping charges. Our commitment

More information

Low Signal Relay. To Order: Select the part number and add the desired coil voltage rating, (e.g., G6A-274P-ST-US-DC12).

Low Signal Relay. To Order: Select the part number and add the desired coil voltage rating, (e.g., G6A-274P-ST-US-DC12). Low Signal Relay High sensitivity can be driven by digital circuits Low-profile design allows use in 12.70 mm (0.50 in) PC board rack Surge withstand voltage meets FCC Part 68 regulation Units can be mounted

More information

ACA-20PC Series Digital, LED-Display AC Ammeters with Built-in Current Transformers

ACA-20PC Series Digital, LED-Display AC Ammeters with Built-in Current Transformers www.murata-ps.com Now Available with Wire Lead CTs FEATURES for direct measurement of 0 to 2/20/50/100 Amps Functionally complete: On-board current transformers Scaling/interface circuitry Precision A/D

More information

AT30 SERIES BATTERY CHARGER

AT30 SERIES BATTERY CHARGER STANDARD FEATURES 5 YEAR WARRANTY 5 Year Product Warranty Universal main control board operates in any AT Series charger Alarm assembly with local LEDs and summary relay contact for AC Failure, DC Failure,

More information

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931 Data Bulletin 0931DB0101 July 2001 Cedar Rapids, IA, USA Ground-Censor Ground-Fault Protection System Type GC Class 931 09313063 GT Sensor Shunt Trip of Circuit Interrupter Window Area for Conductors GC

More information

ELECTRICAL MEASURING INSTRUMENT CHAPTER 15 ELECTRICAL MEASURING INSTRUMENTS THE MOVING COIL GALVANOMETER The moving coil galvanometer is a basic electrical instrument. It is used for the detection or measurement

More information

System 350 S350P Proportional Plus Integral Temperature Stage Module

System 350 S350P Proportional Plus Integral Temperature Stage Module FANs 930, 930.5 Add-On Modules Section Product/Technical Bulletin S350P Issue Date 0997 System 350 S350P Proportional Plus Integral Temperature Stage Module The S350P is used in conjunction with the A350

More information

Type CDG 14 Extremely Inverse Time Overcurrent and Earth Fault Relay

Type CDG 14 Extremely Inverse Time Overcurrent and Earth Fault Relay Type DG 14 Extremely Inverse Time Overcurrent and Earth Fault Relay Type DG 14 Extremely Inverse Time Overcurrent and Earth Fault Relay DG 14 drawn out from the case The type DG 14 relay is a heavily damped

More information

INSTRUCTION MANUAL FOR VOLTAGE REGULATOR APR P/N

INSTRUCTION MANUAL FOR VOLTAGE REGULATOR APR P/N INSTRUCTION MANUAL FOR VOLTAGE REGULATOR APR 125-5 P/N 9168800100 Publication: 9168800990 Revision: J 03/09 INTRODUCTION This instruction manual provides information about the operation and installation

More information

CLIENT: PROJECT: PO#: ESTIMATOR:

CLIENT: PROJECT: PO#: ESTIMATOR: GENERATOR CONTROL DATA SHEET CLIENT: PROJECT: PO#: ESTIMATOR: PRIME MOVER FUEL: RPM: GOVERNOR SPEED ADJUST RHEOSTAT SUPPLIED WITH GOVERNOR: LOAD SHARING: REMOTE: PRIME MOVER PROTECTION LOW OIL PRESSURE

More information

FALL-OF-POTENTIAL GROUND RESISTANCE TESTER

FALL-OF-POTENTIAL GROUND RESISTANCE TESTER FALL-OF-POTENTIAL GROUND RESISTANCE TESTER Models 3620, 3640 & 4610 Call toll free (800) 537-0351 or visit www.allspec.com Measures soil resistivity (4-Point) (Model 4610) Measures ground resistance (2-

More information

Type E-10, E-11 Hazardous Area Explosion-proof Transmitters

Type E-10, E-11 Hazardous Area Explosion-proof Transmitters Electronic Pressure Catalog > Hazardous Area > E-10, E-11 Type E-10, E-11 Hazardous Area Explosion-proof Transmitters Meets ANSI / ISA 12.27.01-2003 single seal requirements - no dual seal required Applications

More information

CP-8551 & CP Application. Features. Applicable Literature. Electronic to Pneumatic Transducers General Instructions

CP-8551 & CP Application. Features. Applicable Literature. Electronic to Pneumatic Transducers General Instructions CP-8551 & CP-8552 Electronic to Pneumatic Transducers General Instructions Application The CP-8551 and CP-8552 transducers receive a variable electronic input signal and produce a 3 to 15 psig (21 to 103

More information

Tel: &

Tel: & C O N T R O L S BRITISH QUALITY COMPANY Split Core Current Transformers & Transducers Primary Currents from 50 to 5000 Amps Accuracy Class 1 & Class 0.5 1 Amp & 5 Amp Secondaries 0-333mV AC Transducer

More information

Cleveland-Kidder Ultra

Cleveland-Kidder Ultra LOW PROFILE Low Profile Load Cell Providing up to a 40:1 Tension Range Performance Benefits Cleveland Motion Controls new Ultra Line Slim Cell is part of the new Line Tension family. a unique low-profile

More information

To study the constructional features of ammeter, voltmeter, wattmeter and energymeter.

To study the constructional features of ammeter, voltmeter, wattmeter and energymeter. Experiment o. 1 AME OF THE EXPERIMET To study the constructional features of ammeter, voltmeter, wattmeter and energymeter. OBJECTIVE 1. To be conversant with the constructional detail and working of common

More information

A.C. 90 & 240º SCALE AMMETERS & VOLTMETERS

A.C. 90 & 240º SCALE AMMETERS & VOLTMETERS A.C. 90 & 2º SCALE AMMETERS & VOLTMETERS Rated burden (ammeter) 1 VA (range 5A) Continuous overload 1.2 In / 1.2 Vn Instantaneous overload In / 2Vn Accuracy 1.5% Operating temperature - + C Manufactured

More information

Power Controller. (see note 1) 10 sec

Power Controller. (see note 1) 10 sec Power Controller Single-phase Models EUN Series AC Power Controller with Phase-control System Allows Precise Temperature Control Models with Base-up and Soft-start Functions Available EH Series Phase Control

More information

Ground Resistance Tester Model 3620 & 3620 Kits

Ground Resistance Tester Model 3620 & 3620 Kits Ground Resistance Tester Model 3620 & 3620 Kits Model 3620 shown in standard soft carrying case Catalog #2114.90 The Analog Ground Resistance Tester Model 3620 performs ground resistance measurements from

More information

Power Switching Devices

Power Switching Devices Watlow has manufactured solid state power controllers for over forty years. Watlow s is a microprocessor-based product that features application flexibility unmatched by any other silicon controlled rectifier

More information

INSTRUCTION MANUAL MODEL PS VDC POWER SUPPLY

INSTRUCTION MANUAL MODEL PS VDC POWER SUPPLY 222 W. Memorial Road, Oklahoma City, OK 73114-2317 Phone: 1-800-624-7697 Fax: 405-755-8425 www.magpowr.com E-mail: magpowr@magpowr.com INSTRUCTION MANUAL MODEL PS-24 24 VDC POWER SUPPLY All of the information

More information

display on the wall or in a panel away from the inline sensor SE30 for easy meter reading.

display on the wall or in a panel away from the inline sensor SE30 for easy meter reading. Analogue Flow Rate Indicator, DN 15...; PN 1...16 Advantages / Benefits Reduced costs of ownership up to 6% Economic integration in pipe systems without any additional piping Shows flow rate with a large

More information

Positions: L1-L2, L1-L3, L2-L3, L1-N, L2-N, L3-N Positions: L1-L2, L1-L3, L2-L3, OFF. Measuring range. Type 144 svs Cat. No

Positions: L1-L2, L1-L3, L2-L3, L1-N, L2-N, L3-N Positions: L1-L2, L1-L3, L2-L3, OFF. Measuring range. Type 144 svs Cat. No 029,1*,521 92/70(7(5 :,7+ &+$1*( 29(5 6:,7&+ 72VS, 96VS, 144sVS, 72VS-1, 96VS-1, 144sVS-1 The instruments are suitable for measuring AC voltages in 4 or 3-wire networks by using a change over switch mounted

More information

5001TCP SPEED CONTROLLER

5001TCP SPEED CONTROLLER VARIABLE SPEED DRIVE CONTROLLER INSTALLATION AND SETTING UP MANUAL 5001TCP SPEED CONTROLLER With PC101 Torque Limit Control WARNING Disconnect all incoming power before working on this equipment. Follow

More information

UNIK 5800/5900. Flameproof/Explosion-Proof Pressure Sensing Platform. GE Measurement & Control. High Quality. Features. Bespoke as Standard.

UNIK 5800/5900. Flameproof/Explosion-Proof Pressure Sensing Platform. GE Measurement & Control. High Quality. Features. Bespoke as Standard. GE Measurement & Control UNIK 5800/5900 Flameproof/Explosion-Proof Pressure Sensing Platform The 5800 and 5900 are compact and rugged versions of the high performance UNIK 5000 pressure sensing platform

More information

Instrumental technique presentation

Instrumental technique presentation Instrumental technique presentation ammeter Manju 28.10.2017 An ammeter is a measuring instrument used to measure the electric current in a circuit. History I A The relation between electric current, magnetic

More information

POWER SUPPLY MODEL XP-800. TWO AC VARIABLE VOLTAGES; 0-120V and 7A, PLUS UP TO 10A. Instruction Manual. Elenco Electronics, Inc.

POWER SUPPLY MODEL XP-800. TWO AC VARIABLE VOLTAGES; 0-120V and 7A, PLUS UP TO 10A. Instruction Manual. Elenco Electronics, Inc. POWER SUPPLY MODEL XP-800 TWO AC VARIABLE VOLTAGES; 0-120V and 0-40V @ 7A, PLUS 0-28VDC @ UP TO 10A Instruction Manual Elenco Electronics, Inc. Copyright 1991 Elenco Electronics, Inc. Revised 2002 REV-I

More information

General Purpose Relay

General Purpose Relay General Purpose Relay Designed small, 2- and 3-pole types break 5 A loads and 4-pole type, 3 A load High reliability, long life Ultra-high sensitivity with quick response High vibration/shock resistance

More information

SPLIT-CORE DC CURRENT TRANSDUCER

SPLIT-CORE DC CURRENT TRANSDUCER SPLIT-CORE DC E6 Applying laminated split core technology and open loop technology split core DC current transducer is designed for strong durability. It improves not only existing errors at the low current

More information

ACA-20PC Series Digital, LED-Display AC Ammeters with Built-in Current Transformers

ACA-20PC Series Digital, LED-Display AC Ammeters with Built-in Current Transformers www.murata-ps.com Now Available with Wire Lead CTs C US E156931 FEATURES for direct measurement of 0 to 2/20/50/100 Amps Functionally complete: On-board current transformers Scaling/interface circuitry

More information

Voltmeter and Ammeter Design

Voltmeter and Ammeter Design EEE3406 Instrumentation & easurements LABOATOY Experiment 2 Name Class Date Class No. arks Voltmeter and Ammeter Design Objectives: After completing this lab, you will be able to measure the full-scale

More information

Table of Contents General Specifications, Available Mountings... 1 Introduction... 2 Application Examples... 3 Features... 4 Theory of Operation... 5

Table of Contents General Specifications, Available Mountings... 1 Introduction... 2 Application Examples... 3 Features... 4 Theory of Operation... 5 With Continuous Position Feedback Catalog AU08-0971/NA September, 2002! Compact Design! Highly Accurate Position Feedback Capability! Electronic Controllers Available! 5 Bore Sizes Table of Contents General

More information

Calibrator Capabilities Function Range Resolution Measure V dc 28 V 1 mv Measure ma dc Source ma dc

Calibrator Capabilities Function Range Resolution Measure V dc 28 V 1 mv Measure ma dc Source ma dc 707 Loop Calibrator Instruction Sheet Introduction The Fluke 707 Loop Calibrator (hereafter, the Calibrator) is a compact sourcing and measuring tool. The Calibrator tests current loops of 0-20 ma or 4-20

More information

5001TCP SPEED CONTROLLER

5001TCP SPEED CONTROLLER INSTALLATION AND SETTING UP MANUAL 5001TCP SPEED CONTROLLER WARNING Disconnect all incoming power before working on this equipment. Follow power lockout procedures. Use extreme caution around electrical

More information

Unit 10 Measuring Instruments

Unit 10 Measuring Instruments Objectives: Unit 10 Discuss the operation of a d Arsonval meter movement. Connect a voltmeter to a circuit. Read an analog multimeter. Connect an ammeter. Measure resistance using an ohmmeter. Analog meters

More information

B CW POWER RELAY

B CW POWER RELAY 41-241.31B CW POWER RELAY nected in such a way that current, (I A ), leads voltage, (V BA ), by 150 degrees when the motor is operating at unity power factor. Loss of excitation to the motor causes a large

More information

Model 10 Electromechanical Totalizer

Model 10 Electromechanical Totalizer Model 10 Electromechanical Totalizer A 6 figure general purpose, rugged, electromechanical counter, either panel or base mounted, with manual knob reset, key reset, or non-reset. Frame and housing provides

More information

Series A DC Link Chokes

Series A DC Link Chokes Table of Contents TABLE OF CONTENTS...1 STANDARD DELIVERY SCHEDULE...2 INTRODUCTION...3 LIST PRICE / CROSS REFERENCE...4 SELECTION & LIST PRICE...5 208 VOLTS (60 HZ)...5 240 VOLTS (60 HZ)...6 400 VOLTS

More information

ches UL File No. E101598

ches UL File No. E101598 Instrument Transformers, Inc. Series Series 95 95 Swit Switches ches UL File No. E101598 INSTRUMENT AND CONTRC ONTROL OL s Instrument and Control Switch is a heavy-duty rotary switch that satisfies the

More information