A.C. 90 & 240º SCALE AMMETERS & VOLTMETERS
|
|
- Angelina Daniels
- 5 years ago
- Views:
Transcription
1 A.C. 90 & 2º SCALE AMMETERS & VOLTMETERS Rated burden (ammeter) 1 VA (range 5A) Continuous overload 1.2 In / 1.2 Vn Instantaneous overload In / 2Vn Accuracy 1.5% Operating temperature - + C Manufactured according to CEI-DIN-VDE-IEC 90º AMMETER DIRECT INPUT 1A TO A F4EAX... F72EAX F96EAX... F14EAX 90º AMMETER CT INPUT X/5A & X/1A F4EAX...X05 F72EAX...X05 F96EAX...X05 F14EAX...X05 F4EAX...X01 F72EAX...X01 F96EAX...X01 F14EAX...X01 90º VOLTMETER DIRECT INPUT V TO 0V F4EVX... F72EVX F96EVX... F14EVX 90º VOLTMETER VT INPUT X/V & X/1V F4EVX...CO F72EVX...CO F96EVX...CO F14EVX...CO 2º AMMETER DIRECT INPUT 1A TO A A4EAX... A72EAX A96EAX... A14EAX 2º AMMETER CT INPUT X/5A & X/1A A4EAX...X05 A72EAX...X05 A96EAX...X05 A14EAX...X05 A4EAX...X01 A72EAX...X01 A96EAX...X01 A14EAX...X01 2º VOLTMETER DIRECT INPUT V TO 0V A4EVX... A72EVX A96EVX... A14EVX 2º VOLTMETER VT INPUT X/V & X/1V Code A B C D -4E E E E A4EVX...CO A72EVX...CO A96EVX...CO A14EVX...CO 1, Third Floor, Al-Hafeez Shopping Mall, Main Boulevard, Gulberg-III, Lahore-Pakistan Tel: Fax: rachena@rachena.com
2 A.C. 90 WATT, VAR & POWER-FACTOR METERS Rated burden (ammeter) 0.5 VA (range 5A) (voltmeter) 3 VA (range V) Continuous overload 1.2 In / 1.2 Vn Instantaneous overload In / 2Vn Accuracy 1.5% Operating temperature + C Manufactured according to CEI-DIN-VDE-IEC WATTMETERS SINGLE-PHASE F4WS F72WS F96WS F14WS 3-P, 3-W, BAL. LOAD F4WY F72WY F96WY F14WY 3-P, 4-W, BAL. LOAD F4WN F72WN F96WN F14WN 3-P, 3-W, UNBAL. LOAD F4WD F72WD F96WD F14WD 3-P, 4-W, UNBAL. LOAD F4WT F72WT F96WT F14WT with separate accessory transducer VARMETERS SINGLE-PHASE F4RS F72RS F96RS F14RS 3-P, 3-W, BAL. LOAD F4RY F72RY F96RY F14RY 3-P, 4-W, BAL. LOAD F4RN F72RN F96RN F14RN 3-P, 3-W, UNBAL. LOAD F4RD F72RD F96RD F14RD 3-P, 4-W, UNBAL. LOAD F4RT F72RT F96RT F14RT with separate accessory transducer POWER FACTOR METERS SINGLE-PHASE F4PS F72PS F96PS F14PS 3-P, 3-W, BAL. LOAD F4PY F72PY F96PY F14PY 3-P, 4-W, BAL. LOAD F4PN F72PN F96PN F14PN with separate accessory transducer CHARACTERISTICS TO BE SPECIFIED Rated current 1 or 5A Rated voltage :R3V; 1:R3V; V; 1V; 2V; 0V; 4V Frequency Hz Code A B C D F4E F72E F96E F14E nominal current In or CT ratio nominal voltage Un or VT ratio operating frequency scale 1, Third Floor, Al-Hafeez Shopping Mall, Main Boulevard, Gulberg-III, Lahore-Pakistan Tel: Fax: rachena@rachena.com
3 DC 90 & 2º SCALE AMMETERS & VOLTMETERS Rated burden (ammeter) mv (ma to A) (voltmeter) 1mA (0Ω/V) Continuous overload 1.2 In / 1.2Vn Instantaneous overload In / 2 Vn Accuracy 1.5% Operating temperature - + C Manufactured according to CEI-DIN-VDE-IEC 90º DC AMMETER INPUT µa TO 0µA F4MUA... F72MUA F96MUA... F14MUA 90º DC AMMETER INPUT 1mA TO ma F4MMA... F72MMA... F96MMA... F14MMA 90º DC AMMETER DIRECT INPUT 1A TO A F4MA... F72MA... F96MA... F14MA... 90º DC VOLTMETER INPUT mv TO 0mV F4MMV... F72MMV F96MMV... F14MMV 90º DC VOLTMETER DIRECT INPUT 1V TO 0V F4MV... F72MV... F96MV... F14MV... 2º DC AMMETER INPUT µa TO 0µA A4MUA... A72MUA A96MUA... A14MUA 2º DC AMMETER INPUT 1mA TO ma A4MMA... A72MMA... A96MMA... A14MMA 2º DC AMMETER DIRECT INPUT 1A TO A A4MA... A72MA... A96MA... A14MA... 2º DC VOLTMETER INPUT mv TO 0mV A4MMV... A72MMV 96MMV... A14MMV 2º DC VOLTMETER DIRECT INPUT 1V TO 0V A4MV... A72MV... A96MV... A14MV... Code A B C D -4E E E E input scale 1, Third Floor, Al-Hafeez Shopping Mall, Main Boulevard, Gulberg-III, Lahore-Pakistan Tel: Fax: rachena@rachena.com
4 SYNCHRONIZING INSTRUMENTS (DOUBLE VOLTMETER 7 FREQUENCY METER) Rated burden 1.5 VA (range V) Operating Frequency Hz (F..YV - F..YVE) Continuous overload 1.2 Vn Instantaneous overload 2Vn Accuracy 1.5% (Voltmeter) 0.5% (Frequency Meter) Operating temperature + C Manufactured according to CEI-DIN-VDE-IEC 96 x x 144 DOUBLE VOLTMETERS F96YV F14YV DOUBLE FREQUENCY METERS F96YF F14YF DOUBLE VOLTMETERS DOUBLE FREQUENCY METERS 96 x 96 F96YVE F96YFE input voltage frequency scale (SYNCROSCOPES) Phase + frequency shift display 2 LED Matching condition flashing green LED Rated burden (line) 3 VA Continuous overload 1,2Vn Instantaneous overload 2 Vn Accuracy 1,5% Operating temperature - + C Manufactured according to CEI-DIN-VDE-IEC Output contact relay 5A/2V Switch operating time 0,5 s Matching indication by LED on front Set-point range ±2,5 % Vn Phase set-point range ±5 ± Frequency set-point range 0,1 1 Hz Set-point trimmers on rear 96 x x 144 LED SYNCROSCOPES F96Y F14Y CHECKING SYNCROSCOPES F96YX F14YX CHARACTERISTICS TO BE SPECIFIED Rated voltage V; 1V; 2V; 0V; 4V; 0V Frequency - - 0Hz Code A B C D F96YV/ YF F14YV/ YF F96YVE/YFE F96Y / YX F14Y / YX input voltage frequency 1, Third Floor, Al-Hafeez Shopping Mall, Main Boulevard, Gulberg-III, Lahore-Pakistan Tel: Fax: rachena@rachena.com
5 DIGITAL & BAR-GRAPH METERS Red LED display mm & 14mm high Continuous overload 2 In / 1.2Vn Accuracy 0.5% Operating temperature + C CODE D44... D4... D76... D72... DIMENSIONS (mm) 4 x 24 4 x 4 72 x x 72 DISPLAY DIGITS 3-3½ 3-3½ 3-3½ 3-3½ MAX. DISPLAY ACCURACY CLASS 0.5% 0.5% 0.5% 0.5% AUX. SUPPLY VOLTAGE 1-2 Va.c. / vdc CODE D9... D9...6 X9... D96... DIMENSIONS (mm) 96 x 4 96 x 4 96 x 4 96 x 96 DISPLAY DIGITS 3-3½+0 4½ 4½ 3-3½+0 MAX. DISPLAY ACCURACY CLASS 0.5% 0.5% 0.5% 0.5% AUX. SUPPLY VOLTAGE 1-2 Va.c. / vdc CODE D X96... B94... DIMENSIONS (mm) 96 x x x 24 DISPLAY DIGITS 4½ 4½ MAX. DISPLAY ACCURACY CLASS 0.5% 0.5% 0.5% AUX. SUPPLY VOLTAGE 1-2 Va.c. / vdc 1, Third Floor, Al-Hafeez Shopping Mall, Main Boulevard, Gulberg-III, Lahore-Pakistan Tel: Fax: rachena@rachena.com
6 ENERGY METERS (DOUBLE VOLTMETER 7 FREQUENCY METER) Rated burden 1.5 VA (range V) Operating Frequency Hz (F..YV - F..YVE) Continuous overload 1.2 Vn Instantaneous overload 2Vn Accuracy 1.5% (Voltmeter) 0.5% (Frequency Meter) Operating temperature + C Manufactured according to CEI-DIN-VDE-IEC CODE C1... C... C... C...L DIMENSIONS 1 DIN 2 DIN 6 DIN 6 DIN DISPLAY LCD Electro-Mechanical LCD 7-digit 7-digits. 2-Rows CURRENT (MAX.) 5 (32)A 5(6)A or 1A or 1A or 16()A 5(6)A 5(6)A ACCURACY CLASS 1 2 (Wh) 2 (Wh) 2 (Wh) 3(Varh) 3(Varh) 3(Varh) ADDITIONAL VARIABLES W, Var, Wavg, Wmax, CODE C52... C... C...L DIMENSIONS 3 DIN 6 DIN 6 DIN DISPLAY Electro-Mechanical LCD 7-digits. 2-Rows CURRENT (MAX.) (1)A DIRECT INPUT ACCURACY CLASS 2 (Wh) 2 (Wh) 2 (Wh) 3(Varh) 3(Varh) 3(Varh) ADDITIONAL VARIABLES W, Var, Wavg, Wmax, CODE C4... C C14... C96...L DIMENSIONS 4x4 96x96-144x144 96x96 DISPLAY Electro-Mechanical Electro LCD 7-digit 7-digits. 7-digits 2-Rows CURRENT (MAX.) 5A or 1A or 1A or 1A or 16()A 5(6)A 5(6)A 5(6)A ACCURACY CLASS 1 2 (Wh) 2 (Wh) 2 (Wh) 3(Varh) 3(Varh) 3(Varh) ADDITIONAL VARIABLES W, Var, Wavg, Wmax, ENERGY METERS FOR DC SYSTEMS CODE C/96/14...C C...CL/ C96...CL DIMENSIONS 6-DIN, 96x96 6-DIN, 96x96 144x144 DISPLAY Electro-Mechanical LCD 7-digit 2-Rows CURRENT (DIRECT) < A < A THROUGH SHUNT mv, mv, 1mV ACCURACY CLASS 2 2 ADDITIONAL VARIABLES W, Var, Wavg, Wmax, basic current or CT ratio nominal voltage or VT ratio 1, Third Floor, Al-Hafeez Shopping Mall, Main Boulevard, Gulberg-III, Lahore-Pakistan Tel: Fax: rachena@rachena.com
7 Multifunction Meters & Network Analyzers CODE MCU Q52... Q96D4 Q...B4W Q...E2 Dimensions 6-DIN 3-DIN 96 x 96 96x96 96x96 6-DIN 6-DIN Display - LCD 4 LED 4 LED LCD 2 rows System Three-phase 3 and 4 wires, unbalanced load MEASUREMENTS AND FUNCTIONS Phase V & I Neutral current Line active & reactive power Total active & reactive power Line apparent power Total apparent power Line power factor Total power factor Frequency Active & reactive energy Thermal current Max thermal current Average power Max. demand Switchboard temp. THD Hours run Phase Sequence CODE QU2 Q...U2S Q...U2L Q96U4L Q96U4H Dimensions 6-DIN 96x96 96x96 96x96 96x96 6-DIN 6-DIN Display LCD LCD LCD LCD LCD 2 rows 2 rows 2 rows 4 rows 4 rows System 3-p, 4W, Single Three-phase 3 and 4 wires, unbal. load unbal. phase MEASUREMENTS AND FUNCTIONS Phase V & I Neutral current Line active & reactive power Total active & reactive power Line apparent power Total apparent power Line power factor Total power factor Apparent power factor Line & Total CosΦ Frequency Active & reactive energy Thermal current Max thermal current Average power Max. demand THD Harmonic analysis Hours run Phase Sequence 1, Third Floor, Al-Hafeez Shopping Mall, Main Boulevard, Gulberg-III, Lahore-Pakistan Tel: Fax: rachena@rachena.com
8 DC Network Analyzers with LCD Display CODE QUCL Q96UCL Dimensions 6-DIN 96x96 Display LCD 2 rows LCD 2 rows System DC DC MEASUREMENTS AND FUNCTIONS Voltage Current Power Average power Max. demand Energy Bi-Directional Ah nominal current or shunt ratio shunt position nominal voltage or divider ratio aux. supply voltage Earth Leakage Relays EARTH LEAKAGE RELAY Code: X52DS current setting range: ma...a in 3 ranges delay setting range 0,1...5 sec in 2 ranges operating frequency Hz trip contact 2 SPDT, 5A 2Vac plus protection for housing IP according to IEC aux. supply voltage TRANSFORMER FOR EARTH LEAKAGE RELAYS Code A B C D E H I TDC TDC TDC TDC TDC TDC SPLIT CORE TRANSFORMERS TDA TDA TDA , Third Floor, Al-Hafeez Shopping Mall, Main Boulevard, Gulberg-III, Lahore-Pakistan Tel: Fax: rachena@rachena.com
9 Current Transformers Code TAC005 TAC0 TAC0 TAC017 TAC021 TAC022 TAT022 TAC032 TAC033 Cable PRIMARY WOUND Ø17 mm Ø21 mm Ø22 mm Ø22 mm Ø24 mm Ø24 mm Busbar in mm x 5 x x 5 x 5 32 x x mm Width (mm) Cl Current BURDENS VA Code TAC0 TAC051 TAC053 Cable Ø32 mm Ø mm Busbar x 51 x 1 51x32 Width (mm) 5 5 Cl Current Code Busbar TAT04 62x34 4x34 Width (mm) 94 Cl Current TAT0 TAT063 TAT061 Ø mm Ø51 mm 63 x 61 x BURDENS VA TAT1 TAT1 TAT126 2x55 127x55 5x3 127x , Third Floor, Al-Hafeez Shopping Mall, Main Boulevard, Gulberg-III, Lahore-Pakistan Tel: Fax: rachena@rachena.com TAT01 TAT0 Ø mm 1 x TAT02 2 x TAT127 TAT12 TAT129 TAT165 TAT2 127x55 127x5 127x5 165x127 2x BURDENS VA
10 Split Core Current Transformers SPLIT-CORE CURRENT TRANSFORMERS Code TAA0 TAA0 TAA1 TAA1 Busbar x x 1 x 165 x 6 Width (mm) Cl Current BURDENS VA Tape Insulated and Resin Impregnated Current Transformers Operating frequency Hz 2 khz insulation reference voltage 0,72 1,2 kv insulation class A-E-B-F protection degree IP IP 54 continuous over current 1,2 5 In operating temperature - + C manufactured according to CEI EN 044-1, IEC 15, VDE, BS, UTE CODE TA0... TA0... TAC... TAR... Ring type Rectangular Primary wound Resin impregnated Summation CT s CODE TASC TAS02 TAS04 Class P P 5+5 A A A A A S - code - input CTs ratio (if different) - options Measuring Voltage Transformers case material: metallic operating frequency Hz dry insulation in air class E protection degree IP rated voltage factor 1,2 continuous Code TTV006 TTV007 TTV0 TTV0 TTV0 TTV Class Burden S - code - VT Ratio - options 1, Third Floor, Al-Hafeez Shopping Mall, Main Boulevard, Gulberg-III, Lahore-Pakistan Tel: Fax: rachena@rachena.com
11 Transducers AC CURRENT & VOLTAGE TRANSDUCER CODE MCOEAQ MCOEVQ MCOEQ3 MCOEV3 Type 1-Input 1-Input 3-Inputs 3-Inputs 1-Output 1-Output 3-Outputs 3-Outputs Nominal value 1 to 5A to 4V 1 to 5A to 4V Operating Frequency Hz and Hz Outputs Nominal value (maximum load) 0-1mA (kω); 0-5mA (3kΩ); 0-mA (7Ω); 4 ma (7Ω); 0-V (>2kΩ). Aux. Supply VAC 1-2 V (±%, 45-65Hz, 6VA) Optional Aux. Supply VAC (±%, 45 65Hz, 6VA) 24V; 4V; 0V VDC (-...+%, 6W) 24V; 4V;1V;2V VAC/DC (6VA/6W) -V; -2V WATT & VAR TRANSDUCER CODE MCOWD MCORD MCOWT MCORT Type Active Reactive Active Reactive Circuit 3-phase, 3-wire, unbal. 3-phase, 4-wire, unbal. Nominal value 1 to 5A, to 4V Outputs Nominal value (maximum load) 0-1mA (kω); 0-5mA (3kΩ); 0-mA (7Ω); 4 ma (7Ω); 0-V (>2kΩ). Aux. Supply VAC 1-2 V (±%, 45-65Hz, 6VA) Optional Aux. Supply VAC (±%, 45 65Hz, 6VA) 24V; 4V; 0V VDC (-...+%, 6W) 24V; 4V;1V;2V VAC/DC (6VA/6W) -V; -2V POWER FACTOR & FREQUENCY TRANSDUCER CODE MCOPY MCOFP Type Phase Angle Frequency Circuit 3-phase, 3-wire Single Phase Nominal value 1 to 5A, to 4V to 4V Outputs Nominal value (maximum load) +0-1mA (kω); +0-5mA (3kΩ); +0-mA (7Ω); 4-mA (7Ω); +0-V (>2kΩ). Aux. Supply VAC 1-2 V (±%, 45-65Hz, 6VA) Optional Aux. Supply VAC (±%, 45 65Hz, 6VA) 24V; 4V; 0V VDC (-...+%, 6W) 24V; 4V;1V;2V VAC/DC (6VA/6W) -V; -2V DC CURRENT & VOLTAGE TRANSDUCER CODE MCOMA MCOMV MCOMA2 MCOMV2 Signal Current Voltage Current Voltage Type 1-Input / 1-Output 1-Input / 2-Outputs Nominal value 1mA-A mv-0v 1mA-A mv-0v Outputs Nominal value (maximum load) +0-1mA (kω); +0-5mA (3kΩ); +0-mA (7Ω); 4-mA (7Ω); +0-V (>2kΩ). Aux. Supply VAC 1-2 V (±%, 45-65Hz, 6VA) Optional Aux. Supply VAC (±%, 45 65Hz, 6VA) 24V; 4V; 0V VDC (-...+%, 6W) 24V; 4V;1V;2V VAC/DC (6VA/6W) -V; -2V nominal current or CT ratio nominal voltage or VT ratio output calibration range aux. supply voltage 1, Third Floor, Al-Hafeez Shopping Mall, Main Boulevard, Gulberg-III, Lahore-Pakistan Tel: Fax: rachena@rachena.com
12 FRER DIRECT MAXIMUM CURRENT RELAY UP TO A TYPE XAC XAC0... XAT XAT1... Cable Ø 23 mm Ø 32 mm Ø 51 mm BAR Size 2 x mm x mm 61 x 31 mm 1 x 55 mm CHARACTERISTIC Rated Current In A Contact Type/ Rating photo-mos / max. ma, 2V, AC1 Alarm Configuration 1% In Intervention Delay 0 6 sec. Contacts NO or NC This innovative product permits to set an over current threshold on the some CT without interposing any measuring relays and without any auxiliary supply source. Two miniature trimmers are available to set the threshold value and the alarm intervention delay. 72x72 mm NETWORK ANALYSERS Three-phase / Single-phase ModBus RTU / PROFIBUS / JOHNSON / ETHERNET TYPE QUBO QUBO BOX (3xCT TAC032) System 3-phase CTs input 3-phase CTs input Inputs -0V 1-5A -0V 3x... / 5A Aux. Supply Voltage 2Vac 2Vac QUBO h-phase power network analyzers, dim.72x72mm, blue LCD display for measurements BT and MT, THD + kwh,-kwh, RS45 ModBus current input from CT 1-5A -0V, 1-2V AC power supply NANO5 - NANO63 - NANO1 Multifunction meters network analyzers, Three phase/ single phase, 3 DIN modules, LCD blue back lighted, low voltage measurements, 1-5A current input or direct 63A - 1A with triple miniature CTs NANOTA3PLO TYPE NANO5 NANO63 NANO1 SYSTEM 3-phase CTs input 3-phase direct input 3-phase direct input INPUTS 0V 1-5A 0V 63A 0V 1A AUX. SUPPLY 2Vac 2Vac 2Vac DIGITAL METERS WITH ALARMS TYPE X9...6 X Dimensions 96x4mm 96x96mm Max indication ± Over Range indication display over Alarms 2 (1 SPDT+1 SPST) Alarm intervention indication by LED LED display h = 14 mm Operating frequency Hz Contacts rating A, 2V AC1 Alarm type programmable MIN / MAX / OFF MULTIRANGE C.T. WITH 4-mA OUTPUT Input Nominal Current In 5 00A Output Nominal Value 4 ma Load 0 1Ω Aux. supply voltage 32Vdc Multi-range current transformers, with loop-powered 4 ma output (also called passive ), are innovative products which permit to get a current measurement directly on a PLC or an acquisition system, without interposition of separated transducers and without auxiliary power connections. A.C. CURRENT TRANSDUCERS WITH INTEGRATED C.T. Range 5 A Operating Frequency Hz; Hz Output 0-1mA ; 0-5mA ; 0-mA ; 4 ma ; 0-V Aux. Supply Voltage 1-2 VAC. (others on request) Input Current Operating frequency Output Aux. supply voltage 1, Third Floor, Al-Hafeez Shopping Mall, Main Boulevard, Gulberg-III, Lahore-Pakistan Tel: Fax: rachena@rachena.com
DPX Electronic + earth leakage
87045 LIMOGES Cedex Phone :+33 5 55 06 87 87 Fax :+33 5 55 06 88 88 DPX 3 250 Electronic + earth leakage CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. ELECTRICAL AND MECHANICAL
More informationCP Automatic capacitor bank
CP 254 - Automatic capacitor bank STE-CP254_V2_général.doc Page 1 CP 254 - General presentation CP 254 is a range of MV capacitor banks designed to be used in electrical networks up to 36kV. The capacitor
More informationPLATINUM SERIES SWITCHBOARD METERS
PLATINUM SERIES SWITCHBOARD METERS www.sifamtinsley.co.uk DATASHEET E471457 Multifunction Meters Transducers & Isolators PLATINUM SERIES SWITCHBOARD METERS Temperature Controllers Converters & Recorders
More informationDPX 1600 Electronic release
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 1600 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND
More informationMetering Products Protection Units Current Transformers. April 1, 2015
Metering Products Protection Units Current Transformers April, 0 With Effect From April, 0 Sr.No Description Model No. Multifunction LED Meters POWER ANALYZER - LED VIPS 80P 00 POWER ANALYZER - LED 0-
More informationDPX 630 Electronic release
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND MECHANICAL CHARACTERISTICS
More informationDPX Electronic. Fiche technique : F01362EN/02 Mise à jour le : 15/12/2011 Créé le : 15/06/2011
87045 LIMOGES Cedex Phone :+33 5 55 06 87 87 Fax :+33 5 55 06 88 88 DPX 3 250 Electronic Reference(s): 420 302/305/307/309/312/315/317/319/332/335/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3.
More informationAcuvim-L Series. Multifunction Power Meter. Max & Min
Series Multifunction Power Meter TRUE-RMS MEASURING OVER/UNDER LIMIT ALARM Max & Min MAX & MIN RECORD POWER QUALITY ANALYSIS TOU, 4 TARIFFS, 12 SEASONS 14 SCHEDULES Metering of Distribution Feeders, Transformers,
More informationANSI Switchboard Meters
ANSI Switchboard Meters High quality range of switchboard instruments with Class 1 accuracy and which complies with American ANSI-C39.1 (1981) specifications. Available in 4 1 /2" case size, the rugged
More informationKD LV Motor Protection Relay
1. Protection Features KD LV Motor Protection Relay Overload (for both cyclic and sustained overload conditions) Locked rotor by vectorial stall Running stall / jam Single phasing / Unbalance Earth leakage
More informationPanel Meters and Accessories Digital Panel Meter
Digital Panel Meter - SE - - X 2 3 4 5 6. Product code 2. Input Signal Mode 48--48X48 72--72X72 96--96X96 94--96X48 3. Function Mode I--current U--voltage P--active power Q--reactive power H--power factor
More informationDIP SWITCH BASED EARTH LEAKAGE RELAY (ELR) WITH CORE BALANCE CURRENT TRANSFORMER (CBCT / ZCT) EL SERIES
PROK DEVICES PRIVATE LIMITED B-80, 2 nd & 3 rd Floor, KSSIDC Industrial estate, 4 th Main Road, 6 th Block, Rajaji Nagar, Bengaluru -560010 Ph no: 080-41480777, 080-41157700, Email:,, www.prokdvs.in DIP
More informationAC Wattmeters and VArmeters
AC Wattmeters and VArmeters The Crompton Instruments Switchboard series of AC Wattmeters and VArmeters incorporate a DC moving coil, pivot and jewel indicator with a micro-circuit watt transducer PCB to
More information3VF3 to 3VF8 Circuit-Breakers
3VF3 to 3VF8 Circuit-Breakers Accessories Operating mechanisms For other s for 3VF3 with knob Rotary drive, complete, scope of supply Cubicle door for 3VF6 Motor operating mechanism for 3VF3 Motor operating
More informationTel: &
C O N T R O L S BRITISH QUALITY COMPANY Split Core Current Transformers & Transducers Primary Currents from 50 to 5000 Amps Accuracy Class 1 & Class 0.5 1 Amp & 5 Amp Secondaries 0-333mV AC Transducer
More informationMetering Products. Metering Products Protection Units April 1, Price List. Price List. With effect from April 1,
Price List Metering Products Metering Products Protection Units With Current effect from Transformers April, 20 With effect from April,20 E-mail: marketing@veritekindia.com Telephone: 022-6294268 Sr.No
More informationLA Motor Protection. A South African Company to be Proud of
LA Motor Protection Relay Physical Address: 298 Soutter Street, Pretoria West Tel: 083 454 6949, +27 12 327 1729 Fax: +27 (0)12 327 1733 Toll Assist: 0860 10 30 41 www.newelec.co.za sales@newelec.co.za
More informationDPX earth leakage DPX 3 -I earth leakage
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 + earth leakage Reference(s) : 420 225/ 227/ 228/229/ 255/ 257/ 258/ 259/ 285/ 287/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3.
More informationM Series 140.D Data Sheet. Two-Point Controller with Moving-Iron or Moving-Coil Movement 90 Dial RW 96 RP 96
Data Sheet M Series 140.D.101.06 RW 96 RP 96 Two-Point Controller with Moving-Iron or Moving-Coil Movement 90 Dial Application The two point controllers RW/RP 96 (M series) with one or two setpoints provide
More informationBulletin 825 SMM Smart Motor Manager
Bulletin 825 SMM Smart Motor Manager Your order must include: Cat. no. of the Smart Motor Manager selected with supply Voltage Suffix Code, Cat. no. of Converter Module selected, and, If required, Cat.
More informationTechnical Datasheet. Compact DC Energy Meter. Multi-Function DC Energy Meter
Preliminary Datasheet Technical Datasheet Compact DC Energy Meter RISH EM DC series is specially designed to measure, display and communicate DC Voltage, Current, Power and Energy to monitor and control
More informationNEPAL ELECTRICITY AUTHORITY (A Government of Nepal Undertaking)
NEPAL ELECTRICITY AUTHORITY (A Government of Nepal Undertaking) Generation Directorate Medium Generation Operation and Maintenance Department SUNDARIJAL HYDROPOWER PLANT REHABILITATION PROJECT Electricity
More informationMedium voltage products HD4/R MV gas circuit-breakers for secondary distribution. Power and productivity for a better world TM
Medium voltage products HD4/R MV gas circuit-breakers for secondary distribution Power and productivity for a better world TM Table of contents 4 1. Description 9 2. How to choose and order the circuit-breakers
More informationDPX 160 Thermal magnetic and trip-free switches DPX-I 160
87045 LIMOGES Cedex Phone : +33 05 55 06 87 87 FAX : +33 05 55 06 88 88 DPX 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND
More informationRVS-DN Digital Reduced Voltage Motor Starter
RVS-DN Digital Reduced Voltage Motor Starter Specification Guide Specification Guide Contents 1.0 Introduction 2.0 Specifications 2.1 Standard Performance Features 2.2 Standard Protection Features 2.3
More informationTechnical Datasheet. Multi-channel support RTC with Data Storage RS485 Output Alarming & Protection Onsite Programmable Load Profile Analysis
Preliminary Datasheet Technical Datasheet Compact DC Energy Meter RISH EM DC series is specially designed to measure, display and communicate DC Voltage, Current, Power and Energy to monitor and control
More informationAlpha EM DC Multi-Function DC Energy Meter. Technical Datasheet. Compact DC Energy Meter
Alpha EM DC Technical Datasheet Compact DC Energy Meter ALPHA EM DC series is specially designed to measure, display and communicate DC Voltage, Current, Power and Energy to monitor and control the target
More informationSECTION MICROPROCESSOR TRIP UNITS FOR LV CIRCUIT BREAKERS. This section is organized as indicated below. Select desired Paragraphs.
SECTION 16904 MICROPROCESSOR TRIP UNITS FOR LV CIRCUIT BREAKERS PART 2 PRODUCTS 01 MANUFACTURERS A. B. C. Eaton * * The listing of specific manufacturers above does not imply acceptance of their products
More informationRAPTOR DEFAULT TEST TEMPLATES
RAPTOR DEFAULT TEST TEMPLATES www.smcint.com PAGE 1 OF 12 The Raptor Default Test Templates in Raptor HH June 2015 General parts of main screen: TEST TEMPLATES: Default test templates are factory configured
More informationEM DC Multi-Function DC Energy Meter
Analogue Meters With Moving - Iron Movement EM DC Compact DC Energy Meter Ziegler EM DC series is specially designed to measure, display and communicate DC Voltage, Current, Power and Energy to monitor
More informationTechnical information
Technical information General Regulations WTL current transformers are special transformers which transfer the primary circuits with prescribed accuracy in smaller secondary circuits. Primary and secondary
More informationObserve all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.
Introduction OPERATING INSTRUCTIONS: MCD REMOTE OPERATOR Order Codes: 175G94 (for MCD 2) 175G361 + 175G9 (for MCD 5) 175G361 (for MCD 3) 1. Introduction 1.1. Important User Information Observe all necessary
More informationampcontrol s Hard rock relay range
ampcontrol s Hard rock relay range TABLE OF CONTENTS Introduction 1 Earth fault lockout and frozen contactor protection EFL 3 Integrated protection PF1 5 IPM V2 7 Earth continuity MEC-1 9 ECM3 11 Earth
More informationGJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector
GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................
More informationElectro Controls. Damper Actuators / Valve Motors WattsIndustries.co.uk
Electro Controls Damper Actuators / Valve Motors - 2017 WattsIndustries.co.uk Damper Actuators / Valve Motors Section 21 DAMPER / VALVE MOTORS 4Nm 2 & 3 POINT EK4.. These small motors can be fitted directly
More informationDPX 630 Thermal magnetic and trip-free switches DPX-I 630
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND MECHANICAL CHARACTERISTICS
More informationElectronic timers CT-S range Function diagrams
CT-S range Function diagrams - X1-Z2 = ON- delay CT-ERS, CT-MBS, CT-MFS t = set delay time / ts = storing time; t = t1 + t2 = OFF-delay CT-AHS, CT-MBS, CT-MFS X1-Z2 t = set delay time / ts = storing time;
More informationTraining & Didactic Systems. Fundamentals of Electrical Engineering
Training & Didactic Systems Fundamentals of Electrical Engineering Catalog WA1E/01 Table of Contents Page Our Service, Our Customers and fields of technology 2 Introduction 4 Instruction modules measuring
More informationApplication of AC Three-Phase Induction Motor of Wound Rotor AEL-ACWRA
Engineering and Technical Teaching Equipment Application of AC Three-Phase Induction Motor of Wound Rotor AEL-ACWRA INTRODUCTION The electric motors are devices capable of transforming electrical energy
More informationMicro Controller based Motor Protection Relay & Motor Management System
Micro Controller based Motor Protection Relay & Motor Management System Micro Controller based Motor Protection Relay :WOD-TUA Features : In built three Phase CTs Extra wide Range : 1 10 A / 7 20 A In
More informationElectronic timers CT-E range Selection and ordering details
Selection and ordering details Characteristics 12 single function and 2 multifunction (24-240VAC/DC) Single or dual supply voltage ranges 24VAC/DC, 110-130VAC, 220-240VAC Output contacts 1c/o contact (250V
More informationIndex. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.
Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv
More informationRVS-DX Digital Reduced Voltage Motor Starter
RVS-DX Digital Reduced Voltage Motor Starter Specification Guide Specification Guide Contents 1.0 Introduction 2.0 Specifications 2.1 Standard Performance Features 2.2 Standard Protection Features 2.3
More information240 Series DIN Panel Meters
An extensive range of 48, 72, 96 and 144mm DIN style panel meters offering measurement of all electrical and electronic parameters. Meters are shock resistant and vibration proof and supplied with terminal
More informationMeters Product Selection Guide
Meters Product Selection Guide Bulletin 22-E C O N T E N T S P 4 Product Line-up P 6 Portable Precision Instruments P 12 Switchboard Instruments 21A Series P 16 Panel Meters CLEAR LINE Series P 2 Panel
More informationDPX Thermal magnetic and trip-free switches DPX 3 -I 630
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 2 6. CONFORMITY
More informationTechnical Data Sheets
GE Consumer & Industrial Power Protection Technical Data Sheets Digital Energy Uninterruptible Power Supply SitePro 400 & 500 kva 400 VAC CE Series 6 Manufactured by: GE Digital Energy General Electric
More informationAnalogue Instruments. DIN Panel Meters. Benefits Low cost Local indication Ease of installation Minimal training Low maintenance Reasonable accuracy
Analogue Instruments High quality analogue instruments designed to measure an extensive range of electrical and electronic parameters. This comprehensive range offers DIN instruments, ANSI switchboard
More informationType CDG 14 Extremely Inverse Time Overcurrent and Earth Fault Relay
Type DG 14 Extremely Inverse Time Overcurrent and Earth Fault Relay Type DG 14 Extremely Inverse Time Overcurrent and Earth Fault Relay DG 14 drawn out from the case The type DG 14 relay is a heavily damped
More informationPhone: Fax: Web: -
Timer - Delay-on-Make The TAC1 Series was designed to delay the operation of a compressor relay. It eliminates the possibility of relay chatter due to half-wave failure of the output. It connects in series
More informationMotors Automation Energy Transmission & Distribution Coatings. UMBW UL489 and UL1077 Thermal-Magnetic MCB
Motors Automation Energy Transmission & Distribution Coatings UMBW UL489 and UL1077 Thermal-Magnetic MCB UL489 AND UL1077 Circuit Protection Overview: Single pole and multi-pole thermal-magnetic minature
More informationThermal Overcurrent Circuit Breaker 3120-F...
Thermal Overcurrent Circuit Breaker 0-F... Description An extremely versatile range of rocker switch/thermal circuit breakers (S-type TO CBE to EN 6094 with trip free mechanism) offering the choice of
More informationApplication of AC Three-Phase Induction Motor of Squirrel Cage AEL-ACINA
Engineering and Technical Teaching Equipment Application of AC Three-Phase Induction Motor of Squirrel Cage AEL-ACINA INTRODUCTION The electric motors are devices capable of transforming electrical energy
More informationJtec 10kA Miniature Circuit Breaker
EN 60898 Jtec 10kA Miniature Circuit Breaker Techna s JTEC range has been enthusiastically adopted by a diverse range of customers seeking a cost effective 10kA performance. Jtec MCBs are available in
More informationSeries Motor Protection
320-327 Series Motor Protection Relay Physical Address: 298 Soutter Street, Pretoria West Tel: 083 454 6949, +27 12 327 1729 Fax: +27 (0)12 327 1733 Toll Assist: 0860 10 30 41 www.newelec.co.za sales@newelec.co.za
More informationICG Switchgear Price List 2009
ICG Switchgear Price List 2009 Section 1 Control Gear Page Contactors (AC,DC & Modular) 2,3 Overload Relays 4 Product Accessories 4,5 Starters-DOL, Star-Delta, Fan/Vibrators, Reversing/Twin 6,7 Section
More informationMBS AG. CTB Plug-in current transformer MBS AG. Dimensions: General technical specifications:
CTB 31.35 Plug-in current transformer Dimensions: Primary conductor 1: 30x10 mm Primary conductor 2: 25x12 mm Primary conductor 3: 20x20 mm Round conductor: 26 mm Transformer width: 60 mm Transformer height:
More informationElectrical Power Electric power electrical electric power Electric power electric electric
Power Calculations Electrical Power Electric power is the rate at which electrical energy is transferred by an electric circuit. The SI unit of power is the watt, one joule per second. Electric power is
More informationntents Meter Product Line-up Usage Precautions View Scale Forms and Divisions Standard Specifications Key to Meters Numbering System DC Ammeters
H Contents Meter Product Line-up Usage Precautions View Scale Forms and Divisions Standard Specifications Key to Meters Numbering System DC Ammeters DC Voltmeters Suppressed Meters (DC Ammeters & Voltmeters)
More informationTechnical Data Sheets
GE Consumer & Industrial Power Protection Technical Data Sheets Digital Energy Uninterruptible Power Supply SitePro 150 200 250 300 kva 400 VAC CE Series 6 Manufactured by: GE Digital Energy General Electric
More informationDATA SHEET Genset Control Unit, GCU 100
DATA SHEET Genset Control Unit, GCU 100 Engine control and protection Generator and busbar protection Emergency genset control Breaker control Easy-to-read graphical display Integrated emulation software
More informationD509E. Manual Motor - Starters
D509E Manual Motor - Starters Index Page Manual Motors Starters 182 Auxilliary Contact Blocks 182 Trip Alarm Aux. Switch 182 Shunt Release 182 Under-voltage Release 183 Accessories 183 Busbar Connectors
More informationApplication of AC Dahlander Three-Phase Induction Motor AEL-ACDHA
Engineering and Technical Teaching Equipment Application of AC Dahlander Three-Phase Induction Motor AEL-ACDHA INTRODUCTION The electric motors are devices capable of transforming electrical energy into
More informationMEASURE TODAY. ENSURE TOMORROW. SpireMag Series T-MAG Electromagnetic BTU Meter
MEASURE TODAY. ENSURE TOMORROW. SpireMag Series T-MAG Features The T-MAG BTU meter is the latest addition to the SpireMag series for accurate thermal energy measurement. It utilizes a high accuracy electromagnetic
More informationTemperature Control Panel Wiring Diagram Model: ISPA-120-1P-15A
Temperature Control Panel Wiring Diagram Model: ISPA-0-P-5A Shift Controls, Inc. Installed Options: TC Jack Panel Connector Interlock Relay, RLY- 5A Power Cord www.shift-controls.com support@shift-controls.com
More informationmax pole for t=15 ms
Types RI 61 RI 61N RI 61J RI 62 RI 62J RI 63 RI 63N RI 64 single-pole single-pole + neutral pole single-pole (for DC circuits) two-pole two-pole (for DC circuits) three-pole three-pole + neutral pole three-pole
More informationEssential equipment for all your requirements
NEW CTX CONTACTORS Essential equipment for all your requirements 9 A TO 310 A THREE-POLE INDUSTRIAL CONTACTORS CTX three-pole industrial contactors, a sense of family The new range of CTX contactors provides
More informationPage. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases
Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar
More informationELECTRIC MACHINES EUROLAB 0.3 kw
index SINGLE-PHASE MOTORS SPLIT-PHASE MOTOR DL 30130 CAPACITOR MOTOR DL 30140 UNIVERSAL MOTOR DL 30150 REPULSION MOTOR DL 30170 THREE PHASE ASYNCHRONOUS MOTORS SQUIRREL CAGE THREE PHASE ASYNCHRONOUS MOTOR
More informationMicro Contactor MA Series
Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC
More informationComponents for EEx e Panels
Circuit Interrupters / Motor Switches 8006/3 8543/1 8543/2 8548/2 40 A 63 A 80 A 1 160 A 500 V 660 V 500 V 01766E00 No. of poles 12 poles Isolator features Switching capacity 400 V, AC3 11 kw 22 kw 37
More informationProduct selection table
Product selection table Equipment Protection Reclosure Associated circuit breaker External toroidal Page REC2 Earth leakage switch -- 47 WRU RA Contactor -- 49 WRU-10 RAL Contactor -- 51 RGU-10 RAL Contactor
More informationTECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out)
TECHNICAL DATA SHEET B8033FXS 10 15 20 kva 3Ph(In) 3Ph(Out) GENERAL INFORMATION UPS Type ON LINE Double Conversion Nominal output power (Cosϕ 0.9) kva 10 15 20 Nominal output power (Cosϕ 1.0) kw 9 13.5
More informationProtection and control P. 1 /2. Smart earth leakage protection
Protection and control P. 1 /2 Smart earth leakage protection P. 1 /2 Smart earth leakage protection Introduction 5 P.1 - Industrial earth leakage protection Product selection table 13 WG Earth leakage
More informationThermal Circuit Breaker 3120-F...
Description The 320 circuit breaker/switch combination is an ON/OFF switch with integral overcurrent protection (S-type TO CBE to EN/IEC 60934). The trip element is a bimetal. Type 320 is ideally suited
More informationPQube 3 Modbus Interface
PQube 3 Modbus Interface Reference manual Revision 1.9 Modbus Interface Reference Manual 1.9- Page 1 Table of Contents 1. Background... 3 2. Basics... 3 2.1 Registers and Coils... 3 2.2 Address Space...
More informationCentury Style Analog Panel Meters
UL Recognized File # E91015 Except for the Wattmeters and Frequency Meters Glass window for optimum viewing Rugged black plastic case Black knife-edge pointer for precision reading The Specifications &
More informationDPX Thermal magnetic and trip-free switches DPX 3 -I 250
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 Reference(s) : 420 205/ 207/ 208/209/ 215/ 217/ 218/ 219/ 235/ 237/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3.
More informationContactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload
According to CE, IEC 947, EN 60947 Contactor Catalogue 3 Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload Mini-Contactors 4kW - 5.5kW DC Contactors Mini-Relays 10A Motor Starter DOL, Star-Delta Capacitor
More informationTesting Energy Storage Systems: From EVs to Utility Grid
Testing Energy Storage Systems: From EVs to Utility Grid Jonathan P. Murray Business Development Manager 2008 Bloomy Controls. All Rights Reserved Agenda Energy storage system landscape Electric vehicle
More informationPOWER SUPPLIES. Control Transformers p8-1 Modular Power Supplies p8-2 Switching Power Supplies p8-3 Automatic Battery Chargers p PAGE
8 POWER SUPPLIES Control Transformers p8-1 Modular Power Supplies p8-2 Switching Power Supplies p8-3 Automatic Battery Chargers p8-10 Perth (08) 9248 0410 Sydney (02) 9676 1671 Melbourne (03) 9706 4599
More informationSoftstarters. Softstarters Type SSM Medium voltage ,800V 1
Medium voltage 2300 13,800V 1 Description Fused disconnect switch with blown fuse indicators and door safety interlocks rated for load break/fault make with automatic grounding arm Inline isolation vacuum
More informationF-Series. Circuit Breaker
F-Series Circuit Breaker The F-Series hydraulic/magnetic high amperage circuit breakers are designed to handle high current applications in extremely hot and/or cold locations. Due to its timeproven hydraulic/magnetic
More informationTechnical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER
Technical Specifications Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER Sentinel PRO CONTENTS 1. GENERAL DESCRIPTION... 2 1.1. Main features of the UPS unit... 3 1.2. Standard Versions...
More informationProtection and control. Self-reclosing overload and earth leakage protection
Protection and control Self-reclosing overload and earth leakage protection P2- Self-reclosing overload and earth leakage protection REC2 Self-reclosing earth leakage relay P2-5 WRU RA Earth leakage relay
More informationINSTALLATION INSTRUCTIONS FOR SYMCOM'S MODEL 777-HVR-SP ELECTRONIC OVERLOAD RELAY
CONNECTIONS INSTALLATION INSTRUCTIONS FOR SYMCOM'S MODEL 777-HVR-SP ELECTRONIC OVERLOAD RELAY BE SURE POWER IS DISCONNECTED PRIOR TO INSTALLATION!! FOLLOW NATIONAL, STATE AND LOCAL CODES! READ THESE INSTRUCTIONS
More informationTHREE-POLE CONTACTORS series HR09-HR13 up to 6 kw
THREE-POLE CONTACTORS series HR09-HR3 up 6 kw USE Series HR contacrs are particularly suitable for controlling mors, heating elements and three-phase and single-phase loads in general. OPERATION AND INSTALLATION
More informationCOUNTIS E22 Three-phase energy meter Direct - 80 A
Instruction manual COUNTIS E22 Three-phase energy meter Direct - 80 A EN www.socomec.com/ en/countis-e2x EN Contents 1. Documentation.... 3 2. Hazards and warnings... 4 2.1. Risk of electrocution, burns
More informationR.4. Automatic capacitor banks with static system. Power factor correction and harmonic filtering. Homepage :
R.4 Power factor correction and harmonic filtering Automatic capacitor banks with static system Mail: Hberk@circutor-nrw.de Homepage : www.berk-iv.de Kontakt: Berk Industrievertretung 51103 Köln Erna Schaeffler
More informationSmart Energy & Power Quality Solutions. Main catalogue 2012/2013. Power Factor Correction / Power quality
Smart Energy & Power Quality Solutions Main catalogue 2012/2013 Power Factor Correction / Power quality Power Quality Solutions Power quality and supply reliability are extremely important in the modern
More informationF-Series. Circuit Breaker
F-Series Circuit Breaker The F-Series hydraulic/magnetic high amperage circuit breakers are designed to handle high current applications in extremely hot and/or cold locations. Due to its timeproven hydraulic/magnetic
More informationEMPAC Metal enclosed capacitor bank for wind applications
EMPAC Metal enclosed capacitor bank for wind applications Introduction The EMPAC is a Metal Enclosed Capacitor Bank suitable for voltages between 1 kv and 36 kv for reactive compensation in MV networks
More informationMU MMMREV.2 09/01 UNI EN ISO ELECTRONIC POWER FACTOR REGULATOR type QR INSTRUCTION MANUAL PAG. 7
MU 03.04.MMMREV.2 09/01 UNI EN ISO 9001 ELECTRONIC POWER FACTOR REGULATOR type QR INSTRUCTION MANUAL PAG. 7 ENGLISH 1. GENERAL 2. INSTALLATION MECHANICAL FIXING ELECTRICAL CONNECTIONS HOW TO CHOOSE the
More informationPower Switching Devices
Watlow has manufactured solid state power controllers for over forty years. Watlow s is a microprocessor-based product that features application flexibility unmatched by any other silicon controlled rectifier
More informationJewell 212, 312 and 412 VISTA Series Analog Panel Meter Series BEST IN CLASS
Application: The VISTA range of analog panel meters offers accurate measurement and indication of most electrical and electronic parameters in industry as per industrial standard case size. Available Models:
More informationReduced Voltage Starters
Reduced Voltage Starters Reduced Voltage Starters- ASTAT XT Soft Starter Description and Features...2-2 Product Number Configuration...2-3 NEMA and IEC Ratings...2-4 Technical Specifications...2-5 Functions...2-6
More informationHD110C Heavy-Duty Digital Multimeter
HD110C Heavy-Duty Digital Multimeter Key features: Measures 1500 VDC CAT IV 1000 V IP67 Rated Magne-Grip holster with magnetic hanging strap No hassle warranty No waiting. No shipping charges. Our commitment
More informationUL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated
11Across the line UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated contactor frame size A/AE/AL A/AE/AL A/AE/AL A/AE/AL A/AE/AL A/AE/AL A/AE/AF A/AE/AF A/AE/AF A/AE/AF A/AE/AF A/AE/AF
More informationSE-125 MANUAL GROUND-FAULT GROUND-CHECK MONITOR
SE-125 MANUAL GROUND-FAULT GROUND-CHECK MONITOR FEBRUARY 14, 2001 REVISION 3 Publication: SE-125-M Document: S95-C125-00000 Printed in Canada. Copyright 2001 by Startco Engineering Ltd. All rights reserved.
More informationHVW701 HVAC Drive with By-Pass
s Automation Energy Transmission & Distribution Coatings HVW701 HVAC with By-Pass Designed Especially for HVAC Systems US.HVW701.By-Pass.07/2017 www.weg.net WEG HVAC-R Products WEG, a leading supplier
More information