SubDrive75/100/150/300/2W MonoDrive, MonoDriveXT
|
|
- Hortense Phillips
- 5 years ago
- Views:
Transcription
1 SubDrive75/00/50/00/W MonoDrive, MonoDriveXT EMA / EMA / EMA R Quick Installation Guide Status État Estado n English... n Français... n Español...
2 SubDrive75/00/50/00/W MonoDrive, MonoDriveXT EMA / EMA / EMA R Quick Installation Guide Contents Location.... Wire Routing Grounding Grounding/Generator Sizing... 7 Wiring/Configuration EMA... 8 Wiring/Configuration EMA Wiring/Configuration SubDriveW... Plumbing... Accessories....
3 Location Mount drive to a sturdy supporting structure (wall or post). EMA - Indoor nly EMA R/EMA - Indoor/utdoor Mount the drive as close as possible to the service entrance panel. 6" 5 cm Allow a 6" (5 cm) clearance around the drive for cooling. 6" 5 cm 6" 5 cm Use the holes and guides provided. (D T drill holes in the drive.) 6" 5 cm Use a dedicated branch circuit for the drive. Wire directly from the service entrance panel. (5A for SubDrive75/MonoDrive/SubDriveW) (0A for SubDrive00/MonoDriveXT) (0A for SubDrive50) (0A for SubDrive00) Service entrance ground rod It is recommended to wire directly to the service entrance panel. (D T wire to a sub panel located in a home.) I HME Sub
4 Wire Routing D T run input power and motor wires together. Separate input power and motor wiring by at least 8" (0. cm) Separate by at least 8" (0. cm) utput lead to motor to exit house as soon as possible. Input power 8" 0. cm Input power Pump When possible D T run drive input power or motor wires in parallel with house wiring. Avoid running out-building wires in parallel with motor wires.
5 Wire Routing K 8" (0. cm) min. 8" (0. cm) min. 90º Cross over other branch circuits and house wiring at 90º. Satellite/ Antenna wire TV Branch Branch Branch 8" (0. cm) min. 8" (0. cm) min. 8" (0. cm) min. 8" (0. cm) min. Telephone If it is necessary to run wiring in parallel, keep drive input power and motor wires at least 8" (0. cm) from other house wiring. 5
6 Grounding Ensure that a proper utility ground rod is present & connected. L L Ensure that a proper utility ground rod is present & connected. A dedicated output ground wire from the drive must be connected to the motor (motor wires and ground wires must be bundled together). A dedicate from the d to the mot wires mus L L Service entrance ground rod An input power ground wire from the supply panel must be connected to the drive. Service entrance ground rod An Pump input power ground wire from the supply panel must be connected to the drive. Pump Use the service entrance panel ground LY. Avoid multiple ground paths. Use the service entrance panel ground LY. Pump 6 multiple ground paths. D T run ground wire separate
7 Grounding/Generator Sizing Use the service entrance panel ground LY. Pump Pump D T run ground wire separate. ground wire MUST be bundled with motor wires. Generator Sizing for SubDrive/MonoDrive Basic generator sizing for the Franklin Electric SubDrive/MonoDrive system is.5 times maximum input watts consumed by the drive, rounded up to the next normal sized generator. Recommended minimum generator sizes: MonoDrive / hp = 000 Watts ( kw) / hp = 000 Watts ( kw) hp = 500 Watts (.5 kw) MonoDriveXT.5 hp = 000 Watts ( kw) hp = 5000 Watts (5 kw) SubDrive75 = 500 Watts (.5 kw) SubDrive00 = 5700 Watts (6 kw) SubDrive50 = 7000 Watts (7 kw) SubDrive00 = 000 Watts ( kw) SubDriveW = 6000 Watts (6 kw) ote: ot to be used on GFIC circuit or externally regulated generators. Verify voltage, hertz and idle speed are appropriate to supply drive. 7
8 Wiring/Configuration-EMA SubDrive75, SubDrive00, SubDrive50, MonoDrive & MonoDriveXT To operate a different pump size, a Configuration Switch (SW) must be positioned to select the correct pump rating. Reference the chart below for appropriate Configuration Switch setting. From Power Source L L L (Input) Configuration Switch SW Sensor Connection SW See chart below for appropriate controller setting. Reference the SubDrive/MonoDrive Installation Manual or inside of lid for more information. Black Red utput to Feed the motor leads through securely attach to the terminals matching the lead colors. Feed the pressure sensor wires through the small enclosure opening and securely attach to the sensor terminals. Power Supply from Circuit Breaker Red Yel (utput) MonoDrive MonoDriveXT SubDrive75 SubDrive00 SubDrive50 / hp (motor).5 hp (motor)* / hp (pump)* hp (pump)*.5 hp (pump)* Blk Cable Feed the 0 V power leads through the large enclosure opening and securely attach to the terminals marked L, and L. Configuration Switch SW MonoDrive MonoDriveXT SubDrive75 SubDrive00 SubDrive50 / hp (motor)* /A hp (pump).5 hp (pump) hp (pump) MonoDrive MonoDriveXT SubDrive75 SubDrive00 SubDrive50 hp (motor) hp (motor).5 hp (pump) hp (pump) hp (pump) *(default) # Switch Underload sensitivity selection FF Position - ormal(default) Position - Low # Switch Steady Flow - Control selection FF Position - Standard(default) Position - Steady Flow 8
9 E RED RV E T IPUT FILTER RV RV E J RV SESR R ADJUST SW FA SW RV8 RV9 RED E6 J YEL (IPUT) E5 T UTPUT FILTER BLK E Wiring/Configuration-EMA SubDrive75, SubDrive00, SubDrive50, MonoDrive & MonoDriveXT To operate a different pump size, a Configuration Switch (SW) must be positioned to select the correct pump rating. Reference the chart below for appropriate Configuration Switch setting. Sensor Connection SESR Red Blk Configuration Switch SW See chart below for appropriate controller setting. Reference the SubDrive/MonoDrive Installation Manual or access cover for more information. From Power Source J L L (Input) REVB BLACK L L (IPUT) Sensor Connection RED YEL BLK (BR) (BLU) (UTPUT) SESR RV0 SESR Red Blk utput to J Configuration Switch SW See chart below for appropriate controller setting. Reference the SubDrive/MonoDrive Installation Manual or access cover for Red Yel Blkmore information. (Brn) (Blue) (Blk) (utput) From Power Source utput to Power Supply From Circuit Breaker Feed the 0 V power leads through securely attach to the terminals marked L, and L. J L L (Input) Feed the pressure sensor wires through the small enclosure opening and securely attach to the sensor terminals. Feed the 0 V power leads through securely attach to the terminals marked L, and L. L L RED (BR) YEL (BLU) (UTPUT) Feed the motor leads through SESR securely attach to the terminals matching the lead colors to the colors shown. Feed the pressure sensor wires through the small enclosure opening and securely attach to the sensor terminals. BLK J Red Yel Blk (Brn) (Blue) (Blk) (utput) Feed the motor leads through securely attach to the terminals matching the lead colors to the colors shown. Configuration Switch SW MonoDrive MonoDriveXT SubDrive75 SubDrive00 SubDrive50 / hp (motor).5 hp (motor)* / hp (pump)* hp (pump)*.5 hp (pump)* MonoDrive MonoDriveXT SubDrive75 SubDrive00 SubDrive50 / hp (motor)* /A hp (pump).5 hp (pump) hp (pump) MonoDrive MonoDriveXT SubDrive75 SubDrive00 SubDrive50 hp (motor) hp (motor).5 hp (pump) hp (pump) hp (pump) *(default) # Switch Underload sensitivity selection FF Position - ormal(default) Position - Low # Switch Steady Flow - Control selection FF Position - Standard(default) Position - Steady Flow 9
10 SESR SHUT-FF Wiring/Configuration-EMA SubDrive00 To operate a different pump size, a Configuration Switch (SW) must be positioned to select the correct pump rating. Reference the chart below for appropriate Configuration Switch setting. Pressure sensor cable connection Make sure the connection is securely made Configuration Switch SW See chart below for appropriate controller setting. Reference the SubDrive/MonoDrive Installation Manual or inside of lid for more information. SESR SHUT-FF IT FA RELAY PFC FA IV FA CM SW SW Sensor Connection From Power Source utput to SESR SHUT-FF L (Input) L Red Yel Blk (Brn) (Blue) (Blk) (utput) Red Blk Wh Grn Power Supply From Circuit Breaker Feed the motor leads through securely attach to the terminals matching the lead colors to the colors shown. Feed the 0 V power leads through securely attach to the terminals marked L, and L. Feed the pressure sensor wires through the small enclosure opening and securely attach to the sensor terminals. (default) Configuration Switch SW SubDrive00 hp (pump) SubDrive00 5 hp (pump) # Switch Underload sensitivity selection FF Position - ormal(default) Position - Low 0 # Switch Steady Flow - Control selection FF Position - Standard Position - Steady Flow (default)
11 T USED PE CIRCUIT SHRT CIRCUIT VEHEATED CTRLLER Wiring/Configuration-SubDriveW SubDriveW To operate a different pump size, a Configuration Switch (SW) must be positioned to select the correct pump rating. Reference the chart below for appropriate Configuration Switch setting. DISPLAY STATUS Run Mode Configuration Switch SW See chart below for appropriate controller setting. Reference the SubDrive/MonoDrive Installation Manual or inside of lid for more information. From Power Source SW 6 7 # -9 Idle Mode Sleep Mode Reference the ESSURE SubDrive/MonoDrive SESR C Installation Manual or inside of lid for more information. CM L L (Input) L L (IPUT) BLK BLK (UTPUT) Feed the 0 V power leads through the large enclosure opening and securely attach to the terminals marked L, L and. Power Supply From Circuit Breaker Cable to Pressure Sensor SESR C CM Sensor Connection SESR Red Blk utput to BLK BLK (utput) Feed the motor leads through the large enclosure opening and securely attach to the terminals matching the lead colors to the colors shown. Sleep button Depress to engage sleep mode Depress again to resume normal operation See install manual for detailed description Configuration Switch SW SubDriveW / hp (motor) SubDriveW / hp (motor)* SubDriveW hp (motor) *(default) # Switch Underload sensitivity selection FF Position - ormal (default) Position - Low # Switch Reserved - Do not use.
12 Plumbing Minimum Pressure Tank Size (Total Capacity) Pump Flow Rating Controller Model Minimum Tank Size SubDrive75 or MonoDrive gallons (8 L) Less than gpm SubDrive00 gallons (8 L) SubDrive50 or MonoDriveXT gallons (8 L) SubDrive00 8 gallons (5 L) SubDrive75 or MonoDrive gallons (8 L) gpm and higher SubDrive00 8 gallons (5 L) SubDrive50 or MonoDriveXT 8 gallons (5 L) SubDrive00 0 gallons (80 L) All flows SubDriveW 0 gallons (80 L) The pressure tank pre-charge setting should be 70% of system pressure sensor setting. Pressure Setting Guide Pump 6 ft (.8 m) max Pressure WARIG Submersible pumps can develop very high pressure in some situations. Always install a pressure relief valve able to pass full pump flow at 00 PSI. Install the pressure relief valve near the pressure tank. Gauge Pressure Relief Valve Pressure Sensor (Discharge into drain rated for max pump output at relief pressure.) Pressure Shut-off Sensor Turn right (clockwise) to increase pressure setting. Turn left (counter clockwise) to decrease pressure setting. ¼ turn = psi Drain Valve SubDrive00 only 7/ " Allen-wrench (provided) Pressure sensor factory preset for 50 psi Pressure Sensor Set Point (PSI) (Factory set) Pressure Tank Pre-charge (± PSI) on-adjustable Pressure switch factory preset for 00 psi Position the pressure sensor between vertical (preferred) and horizontal. SESR CUT-FF SWITCH SubDrive00 only Position the pressure switch between vertical (preferred) and horizontal. Accessories Pressure Sensor Kit - replacement sensor with 0 ft of AWG cable and sensor adjustment tool: (SubDrive75/00/50, MonoDrive, MonoDriveXT, SubDriveW) Sensor Cable Kit - 00 feet of AWG pressure sensor cable: (SubDrive75/00/50, MonoDrive, MonoDriveXT, SubDriveW) Pressure Sensor Kit - replacement sensor, pressure shut-off switch with 0 ft of AWG cable and sensor adjustment tool: (SubDrive00) Sensor Cable Kit - 00 ft of AWG pressure sensor and pressure shut-off switch cable: (SubDrive00) Fan Replacement Kit - refer to Installation Manual, Franklin Electric hotline or for additional information.
SubDrive75/100/150/300/2W MonoDrive, MonoDriveXT
SubDrive75/00/50/00/W MonoDrive, MonoDriveXT EMA / EMA / EMA R Quick Installation Guide Status État Estado English... Français... Español... SubDrive75/00/50/00/W MonoDrive, MonoDriveXT EMA / EMA / EMA
More informationSubDrive75/100/150/300/2W MonoDrive, MonoDriveXT
Status État Estado SubDrive75/00/50/300/2W MonoDrive, MonoDriveXT Constant Pressure Controller Installation Manual ATTETI! IMPRTAT IFRMATI FR ISTALLERS F THIS EQUIPMET! THIS EQUIPMET IS ITEDED FR ISTALLATI
More informationCONSTANT PRESSURE CONTROLLERS
CONSTANT PRESSURE CONTROLLERS SUBDRIVE AND MONODRIVE Franklin Electric s SubDrive and MonoDrive constant pressure controllers provide constant pressure by continually adjusting the speed of the pump to
More informationCONSTANT PRESSURE CONTROLLERS
CONSTANT PRESSURE CONTROLLERS SUBDRIVE AND MONODRIVE Franklin Electric s SubDrive and MonoDrive constant pressure controllers provide constant pressure by continually adjusting the speed of the pump to
More informationPressure Master. SubDrive MonoDrive E-Z Pac 3/15
Pressure Master SubDrive MonoDrive E-Z Pac 3/15 Table of Contents Page General Information...2-3 MONODRIVE 6617-432 1/2, 3/4, & 1 HP...4-5 MONODRIVEXT 6617-434 1 1/2 & 2 HP...6-7 SUBDRIVE 15 6617-433 NEMA
More informationConstant Pressure - Variable Speed Drive Systems
Constant Pressure - Variable Speed Drive Systems FW121 211 Supersedes 11 COMMANDER PRO CP75, CP1 and CP15 COMPLETE PACKAGED CONSTANT PRESSURE SYSTEMS DESIGNED FOR THE PROFESSIONAL PUMP INSTALLER LIMITED
More informationElectronic Products ELECTRONIC MAINTENANCE
SubDrive2W, 75, 100, 150, 300, MonoDrive, and MonoDrive XT Should an application or system problem occur, built-in diagnostics will protect the system. The FAULT light or digital display on the front of
More informationCOPYRIGHT INFORMATION
COPYRIGHT INFORMATION Franklin Electric Technical Publications 9255 Coverdale Road Fort Wayne, IN 46809 Copyright 2018, Franklin Electric, Co., Inc. All rights reserved. The entire contents of this publication
More information(0.5 HP PUMP END, 0.5 HP MOTOR)
MONODRIVE 15 GPM 15-3WQP-.5HP-3R (.5 HP PUMP END,.5 HP MOTOR) 2 18 16 14 6 HZ PERFORMANCE 12 8 6 5 FT 4 1. GPM 2 3 HZ PERFORMANCE 2 4 6 8 12 14 16 18 18.8 15.6 13.7 11.1 5.5 1 2.2 18.3 15.2 13.4 1.5 4.4
More informationCommander Pro 100 SUBMERSIBLE SYSTEM Installation, Operation and Trouble-Shooting Manual
Commander Pro 100 SUBMERSIBLE SYSTEM Installation, Operation and Trouble-Shooting Manual FW1206 0608 Supersedes NEW Owner Information System Model Number Pump Model / Date Code Pump Serial Number (Silver
More informationBULLETIN BAQSOLO AQUAVAR SOLO CONSTANT PRESSURE CONTROLLERS FOR: 1Ø 3-WIRE MOTORS, 1Ø 2-WIRE CENTRIPRO MOTORS, 3Ø MOTORS
BULLETIN BAQSOLO AQUAVAR SOLO CONSTANT PRESSURE CONTROLLERS FOR: 1Ø 3-WIRE MOTORS, 1Ø 2-WIRE CENTRIPRO MOTORS, 3Ø MOTORS FEATURES NEMA 3R Enclosure: Rainproof, outdoor/ indoor rated enclosure. Current
More informationFlow-Thru Expansion Tanks
Flow-Thru Expansion Tanks FT 66, FT 144 & FT 266 Available by special order. These new tanks include the controlled action diaphragm that makes Flexcon tanks the industry s best. In addition, they have
More information4" SUBMERSIBLE PUMP. ST SERIES (stainless steel) FEATURES. OPTION Extended 5 years warranty plan offered by the manufacturer
Section: 7 Page: 1 Cancel & replace: February 14, 5 4" SUBMERSIBLE PUMP ST SERIES (stainless steel) The "ST" (stainless steel) series of submersible pumps are built with precision to provide a superior
More informationSubDrive75/100/150/300 MonoDrive, MonoDriveXT
SubDrive75/100/150/300 MonoDrive, MonoDriveXT Constant pressure controller Additonal information Additional information for for Australia, NZ NZ for Australia, NZ 1 TOLL FREE HELP 1300 FRANKLIN ! WARNING
More information(1 HP PUMP END, 1.5 HP MOTOR)
SD15 2 GPM 2SDQP-1.5HP-3R (1 HP PUMP END, 1.5 HP MOTOR) 4 3 2 7 HZ PERFORMANCE 2 FT 1. GPM 1 3 HZ PERFORMANCE 1 15 2 25 3 35 4 2 4 6 8 1 12 14 16 18 2 25 3 34 32 31 3 29 27 26 21 16 1 34 32 31 3 29 27
More informationCommander Pro Variable Speed Controller System Instructions
Commander Pro Variable Speed Controller System Instructions The Commander Pro Variable Speed Controller is a dependable water system Variable Frequency Drive (VFD) that uses custom programming to enhance
More informationSOLAR SUBMERSIBLE PUMP CONTROLLER. SubDrive Solar. Installation Manual
SOLAR SUBMERSIBLE PUMP CONTROLLER SubDrive Solar Installation Manual 2 SubDrive Solar Installation Manual Table of Contents Overview... 5 Descriptions and Features... 5 How it Works... 6 Features... 8
More informationInstallation and Operating Instructions
PUMP PROTECTION SYSTEM Installation and Operating Instructions Congratulations on your purchase of a Franklin Electric pump protection system. Pumptec-Plus is the most sophisticated pump protection system
More informationACCESSORY KIT INSTALLATION INSTRUCTIONS
ACCESSORY KIT INSTALLATION INSTRUCTIONS GENERAL Low Ambient Accessory For Air Cooled Split-System Air Conditioners HA 00, HB 60 / 80 / 600, HF-25, HL-0 / -0 / -50 Models These split-system condensing units
More informationCommander Pro Variable Speed Controller System Instructions
Commander Pro Variable Speed Controller System Instructions The Commander Pro Variable Speed Controller is a dependable water system Variable Frequency Drive (VFD) that uses custom programming to enhance
More informationACCESSORY KIT INSTALLATION INSTRUCTIONS
ACCESSORY KIT INSTALLATION INSTRUCTIONS Low Ambient Accessory For Air Cooled Split-System Air Conditioners HA 00, HB 60 / 80 / 600, HF-25, HL-0 / -0 / -50 Models GENERAL These split-system condensing units
More informationOCTOPUS SELECTION & INSTALLATION GUIDE
OCTOPUS SELECTION & INSTALLATION GUIDE CRB SERIES CONTINUOUS RUNNING PUMPSET A. GENERAL DESCRIPTION: Octopus CRB pumpsets are heavy duty, continuously running, electric motor driven pumps which are used
More informationSOLAR SUBMERSIBLE PUMP CONTROLLER. SubDrive Solar. Installation Manual
SOLAR SUBMERSIBLE PUMP CONTROLLER SubDrive Solar Installation Manual SUBDRIVE SOLAR INSTALLATION MANUAL TABLE OF CONTENTS Overview... 5 Inspection... 5 Descriptions and Features... 5 Protection Features...
More informationCP PACKAGE SYSTEM WEBTROL. CP Package System. 4 Constant Pressure Submersible Pump System
CP Package System The Webtrol CP Package System is an innovative drive system that solves what has plagued rural homeowners for years, getting city-like (constant) water pressure from their wells. People
More informationCentrifugal Constant Pressure Control
Operating Instructions & Parts Manual Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others
More information4" SUBMERSIBLE PUMP 4" SUBMERSIBLE PUMP. "GS" series. "ST" series. "SL" series. ST Series (stainless steel) SL Series (thermoplastic)
4" SUBMERSIBLE PUMP 4" SUBMERSIBLE PUMP ST / GS SERIES (stainless steel) SL SERIES (thermoplastic) The "ST / GS / SL" series are built with such precision that they provide a superior output for many years.
More informationCentrifugal Constant Pressure Control
Operating Instructions & Parts Manual Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others
More informationSUBMERSIBLE PUMPS FLINT & WALLING SERIES STAINLESS STEEL C/W MOTOR 4" - 3 WIRE - SINGLE PHASE AND CONTROL BOX
SUBMERSIBLE PUMPS FLINT & WALLING SERIES STAINLESS STEEL Page 1 APRIL 1, 2016 C/W MOTOR 4" - 3 WIRE - SINGLE PHASE AND CONTROL BOX Part US No. Model HP Volts GPM Stages Price M8469690 4F05S05 1/2 115 5
More informationCleaning Systems Inc. 2 P Rev:03
CHEMPOD Table of Contents Overview... 3 Specifications... 3 Dimensions... 3 Weight... 3 Electrical Voltage... 3 Capacity... 3 Product Supply... 3 Pneumatic Supply... 3 Optional Installation Kits... 3 Locating
More informationHP COOL TECH, INC. COOLANT PUMP. PowerPump. INSTALLATION MANUAL HANWHA XD20 Series 10000/11000
HP COOL TECH, INC. COOLANT PUMP PowerPump INSTALLATION MANUAL HANWHA XD20 Series 10000/11000 1 TABLE OF CONTENTS Page Topic 3 Introduction 3 Specifications 3 Warning 4 Safety 5, 6, 7 Installation 8 Use
More informationINSTALLATION and OPERATION INSTRUCTIONS
Part Numbers: 54580 and 54580-2 Part Number 54580 Shown OUT IN INSTALLATION and OPERATION INSTRUCTIONS TABLE OF CONTENTS Section Page Warranty.... 2 General Information.... 3 Introduction..... 3 System
More informationACCESSORY KIT INSTALLATION INSTRUCTIONS Low Ambient Accessory For Air Cooled Split System Air Conditioners HB 180/240, HF -15,-20 Models Only
ACCESSORY KIT INSTALLATION INSTRUCTIONS Low Ambient Accessory For Air Cooled Split System Air Conditioners HB 180/240, HF -15,-20 Models Only GENERAL These split-system condensing units are designed to
More informationEcoVFC. Installation and Owner s Manual
EcoVFC Eco VARIABLE FREQUECY CTRLLER Installation and wner s Manual FFS Rev Franklin Fueling Systems Marsh Rd. Madison, WI USA Tel: + Fax: + www.franklinfueling.com Important Safety Messages FE Petro equipment
More informationCOMMANDER PRO VARIABLE FREQUENCY DRIVES
COMMANDER PRO VARIABLE FREQUENCY DRIVES FW1677 518 Supersedes 318 DESIGNED FOR THE PROFESSIONAL PUMP INSTALLER Easy to read diagnostic display Increases flow as demand increases Available with pressure
More informationFHOTON Drive. Installation Guide
FHOTON Drive Installation Guide 2 SUBDRIVE SOLAR INSTALLATION MANUAL TABLE OF CONTENTS Overview...5 Descriptions and Features...5 How it Works...6 Features...8 Installation...11 Controller Location Selection...
More informationOwner s Manual. Features
Owner s Manual Pumptec is a microcomputer based pump protection device that continuously monitors motor load and power line conditions to provide protection against dry well conditions, waterlogged tanks,
More informationInstallation and Operating Instructions
Installation and Operating Instructions Congratulations on your purchase of a Franklin Electric pump protection system. Pumptec-Plus is the most sophisticated pump protection system on market today. It
More informationINSTRUCTION MANUAL IM260 AQUAVAR SOLO 2 CONSTANT PRESSURE CONTROLLER INSTALLATION, OPERATION AND TROUBLESHOOTING MANUAL
INSTRUCTION MANUAL IM260 AQUAVAR SOLO 2 CONSTANT PRESSURE CONTROLLER INSTALLATION, OPERATION AND TROUBLESHOOTING MANUAL Owner s Information Controller Model Number: Controller Serial Number: Pump Model
More informationInstallation. Part A, Section 3. This section covers the following unit configurations. 3400V 3500V. Voltage 4. Pump Piston (E, F, G)
Part A, Section 3 Model This section covers the following unit configurations. Voltage 4 300V 3400V 3500V Pump Piston (E, F, G) Manifold Control 4-Port (A) 6-Port (B or C) -Port (S or T) Vista Pattern
More informationOwners Manual. Features
Owners Manual Pumptec is a microcomputer based pump protection device that continuously monitors motor load and power line conditions to provide protection against dry well conditions, waterlogged tanks,
More informationInstallation. Part A, Section 3. This section covers the following unit configurations. 3400V 3500V. Voltage 4. Pump Piston (E, F, or G)
Part A, Section 3 Model This section covers the following unit configurations. Voltage 4 3100V 3400V 3500V Pump Piston (E, F, or G) Manifold Control 4-Port (A) 6-Port (B) Vista Temperature (TC) A 3-0 A
More informationTRAC-Station BT Installation Instructions
TRAC-Station BT Installation Instructions P/N 10103024P1 November 2011 2011 UTC Fire & Security. All rights reserved. Introduction This is the Supra TRAC-Station BT Installation Instructions. Read these
More informationOCTOPUS SELECTION & INSTALLATION GUIDE Rev. C CRA SERIES CONTINUOUS RUNNING PUMPSET
A. GENERAL DESCRIPTION: OCTOPUS SELECTION & INSTALLATION GUIDE Rev. C CRA SERIES CONTINUOUS RUNNING PUMPSET Octopus CRA continuous running pumps are very reliable quiet and efficient devices which will
More informationOwners Manual. Features
Owners Manual Pumptec is a microcomputer based pump protection device that continuously monitors motor load and power line conditions to provide protection against dry well conditions, waterlogged tanks,
More informationInstallation. Part A, Section 3. This section covers the following unit configurations. Voltage 1, 2, 3. Vista Standard (V) A3EN-04-[3V-A-AAXV]-11
Part A, Section 3 This section covers the following unit configurations. Model All Voltage 1, 2, 3 Pump All Manifold All Control Vista Standard (V) A 3-0 A 3-1 Section A 3 WARNING: Allow only qualified
More informationUsers Manual Professional Series Direct Drive Pump.25-2 GPM Series Safety, Operating, Installation, and Maintenance Instructions
Users Manual Professional Series Direct Drive Pump.25-2 GPM Series Safety, Operating, Installation, and Maintenance Instructions 600 S 56 th Street #9 Chandler, AZ 85226 Phone: 480-507-6478 Fax: 480-838-2232
More informationELECTRICAL SYSTEM RP-7
ELECTRICAL SYSTEM RP-7 This section of the manual does not include integral electrical components of the engine. Refer to section Engine RP-1 for details. This section of the manual is divided into three
More informationTECHNICAL PAPER 1002 FT. WORTH, TEXAS REPORT X ORDER
I. REFERENCE: 1 30 [1] Snow Engineering Co. Drawing 80504 Sheet 21, Hydraulic Schematic [2] Snow Engineering Co. Drawing 60445, Sheet 21 Control Logic Flow Chart [3] Snow Engineering Co. Drawing 80577,
More informationWebtrol s Family of Pumps
www.webtrol.com Webtrol s Family of Pumps Vertical Series Booster Pumps Stainless Steel Multistage Centrifugals The Webtrol V Series multistage pumps offer technically advanced designs to meet market demands
More informationTrack Drive Circuit - General System. Simplified Travel Circuit Diagrams: Neutral Controls Forward Travel Reverse Travel
Section 7.1 Track Drive Circuit - General System Simplified Travel Circuit Diagrams: Neutral Controls... 7.1.2 Forward Travel... 7.1.4 Reverse Travel... 7.1.5 General... 7.1.3 Track Drive Circuit: General...
More informationVARNA Products 15 GPM (57 LPM) Prelube Kit for MTU 4000 Series Marine Engines
VARNA Products 15 GPM (57 LPM) Prelube Kit for MTU 4000 Series Marine Engines Installation and Users Manual For the following Prelube Kits: VARNA Products P/N 6423 Kit for 208 VAC 3 Phase VARNA Products
More information24000 Series. High Flow 4 Stainless Steel GPM 6/13
24000 Series High Flow 4 Stainless Steel 35-80 GPM 6/13 General Information Page General Information...2-3 24000 Series Pumps R Series - 35 GPM...4-5 G Series - 40 GPM...6-7 S Series - 55 GPM...8-9 Q Series
More informationSubDrive Inline Constant pressure controller Additional information for Australia, NZ TOLL FREE HELP 1300 FRANKLIN
SubDrive Inline 1100 Constant pressure controller Additional information for Australia, NZ 1 TOLL FREE HELP 1300 FRANKLIN ! WARNING Serious or fatal electrical shock may result from failure to connect
More informationDry Vacuum System. Part Numbers: V15, 2V15, 3V15 and 4V15 USER S MANUAL. Recommend Daily use of Monarch CleanStream
Dry Vacuum System Part Numbers: V15, 2V15, 3V15 and 4V15 USER S MANUAL Recommend Daily use of Monarch CleanStream TABLE OF CONTENTS Description Page Congratulations...3 Purpose of this Manual....3 Safety
More informationMODEL 233P/111P/233P-1.5
II-111-233-15P-B INSTALLATION INSTRUCTIONS Revision C Rapid City, SD, USA, 07/2015 MODEL 233P/111P/233P-1.5 BE SURE POWER IS DISCONNECTED PRIOR TO INSTALLATION! FOLLOW NATIONAL, STATE AND LOCAL CODES.
More informationITS-50R TRANSFER SWITCH OWNER S MANUAL
ITS-50R OWNER S MANUAL IOTA Engineering Transfer Switches provide automatic power switching between two or three separate 120/240 volt AC input sources, including powercords, onboard generators, onboard
More informationw w w.apc.com Home Appliance & Lighting UPS HI800SQ Installation Guide and User s Manual
w w w.apc.com Home Appliance & ighting UPS HI800SQ Installation Guide and User s Manual 990-2391D Copyright 2009 American Power Conversion. All rights reserved. APC is a registered trademark of American
More informationInstallation. Part A, Section 3. This section covers the following unit configurations: 3400V 3500V Voltage 1, 2, 3 Pump Piston (E, F, G)
Part A, Section 3 Model This section covers the following unit configurations: 3100V 3400V 3500V Voltage 1, 2, 3 Pump Piston (E, F, G) Manifold Control 4-Port (A) 6-Port (B) Vista Temperature (TC) A 3-0
More informationSection 7.1. Wheel Drive Circuit - General System
Section 7.1 Wheel Drive Circuit - General System Simplified Travel Circuit Diagrams: Neutral Controls... 7.1.2 Forward Travel... 7.1.4 Reverse Travel... 7.1.5 General... 7.1.3 Wheel Drive Circuit: General...
More informationModel &
PumpAgents.com - Click here for Pricing/Ordering Model 31765-0092 & 31765-0094 Dual Sensor Max VSD WATER PRESSURE SYSTEM AUTOMATIC TWO STAGE WATER SYSTEM WITH PUMPGARD STRAINERS IDEAL FOR PLEASURE AND
More informationMizer Single Pump and Starter Box
Mizer Single Pump and Starter Box Table of Contents Line Diagram... 2 Overview... 3 Booster Pump Specifications... 3 Water... 3 Electrical... 3 Models... 3 Mounting... 4 Electrical... 6 Motor Rotation...
More informationUPPCO SERVICE MANUAL
Revised 01/2015 Section 6 ELECTRIC SERVICE - GENERAL Page 1 of 10 Section 6 Electric Service - General 6-1 Number of Services and Voltages / Meter... 2 6-2 Energy Conversion Factors... 7 6-3 Lightning
More informationGENERAL ELECTRIC CONCEALED CHILLED WATER FAN COIL UNITS
GENERAL ELECTRIC CONCEALED CHILLED WATER FAN COIL UNITS ACWL Series ACWL0 thru ACWL4 00 CFM thru 400 CFM GE_ACWL_series.indd 3// : PM CONTENTS Model decoding 3 Unit features 3 Standard specifications 3-4
More informationOwner s Manual. For Automatic Transfer Switch. 50 & 100 Amp. Model Number RTG10EZA1 RTG12EZA1 RTG16EZA1 MODEL NUMBER: SERIAL NUMBER: DATE PURCHASED:
Owner s Manual For Automatic Transfer Switch 50 & 100 Amp Model Number RTG10EZA1 RTG12EZA1 RTG16EZA1 MODEL NUMBER: SERIAL NUMBER: DATE PURCHASED: Register your Generac product at: WWW.GENERAC.COM 888-436-3722
More informationInstallation and Operations Manual
Excalibur Water Systems 3.0 High Capacity Superflow Series QUADPLEX Water Softener Installation and Operations Manual 142 Commerce Park Drive, Units M-O, Barrie ON L4N 8W8 www.excaliburwater.com Water
More informationUL/NEMA Type 1 & Type 12 FRENIC-HVAC Combination VFD
UL/NEMA Type 1 & Type 12 FRENIC-HVAC Combination VFD Safety Precautions Read this manual thoroughly before proceeding with installation, connections (wiring), or maintenance and inspection. Ensure you
More informationACCESSORY KIT INSTALLATION INSTRUCTIONS
ACCESSORY KIT INSTALLATION INSTRUCTIONS Low Ambient Accessory For Air Cooled Split-System Air Conditioners HA 300, HB 360 / 480 / 600, HF-25, HL-30 / -40 / -50 Models GENERAL These split-system condensing
More informationJ1 Plug Pin Identification
D5 D8 D7 D4 D5 D ART_8 J 4 8 D D0 7 R R R R4 TB 80 D D D D4 D D J Plug Pin Identification PIN # WIRE # SIGNAL FUNCTION 0 INPUT Drive Reverse INPUT Drive Forward OUTPUT Brake, Decel Valve signal 4 8 INPUT
More informationCommitment To Quality
Commitment To Quality Franklin Electric is committed to provide customers with defect free products through our program of continuous improvement. Quality shall, in every case, take precedence over quantity.
More informationACCESSORY KIT INSTALLATION INSTRUCTIONS
ACCESSORY KIT INSTALLATION INSTRUCTIONS Low Ambient Accessory For Air Cooled Split-System Air Conditioners HA300, HB360/480/600, HF-25, HL-30/-40/-50 and J25HA, J30/40/50 HB Models GENERAL These split-system
More informationDefender Series. Overfill Prevention Valve. Automatic Shutoff for USTs. Installation, Operation and Maintenance Series
Defender Series Overfill Prevention Valve Automatic Shutoff for USTs Installation, Operation and Maintenance 708-590 Series For use in 4" gravity-fill applications only 25-370 Gallons per Minute flow Compatible
More information4 WT SERIES SUBMERSIBLE
4 WT SERIES SUBMERSIBLE Webtrol s 4 WT Series Webtrol s WT Series pumps offer superior performance and exceptional resistance to abrasives, due to the floating stack design. An excellent choice for residential
More information3 Phase Smart Controller
3 Phase Smart Controller Installation and Owner s Manual STP-SCIII 208-230 VAC, 60Hz, 120 Volt Coil Franklin Fueling 3760 Marsh Rd. Madison WI 53718 USA Tel: +1 608 838 8786 800 225 9787 Fax: +1 608 838
More informationCombo HPU Kidney Loop Motor
Serial #: See below Product Bulletin # DC-002 Combo HPU Kidney Loop Motor Serial numbers DC1041-DC1050, DC1052, DC1053, DC1055-DC1057, DC1062, DC1064, DC1068, DC1070, DC1072 Background The Combo HPU Part
More informationScrew. (Note 4) Spacer for 1" filter ILL. 3. Screw
ICP INSTALLATION INSTRUCTIONS for (NPECOMZR006A00) ICP's economizer is convertible-it will work in either a down discharge or horizontal discharge application. Read these instructions completely and carefully
More informationUser s and Installation Manual
Dry Vacuum System Part Numbers V3, V5, V7, 2V3, 2V3CT, 2V5, 2V5CT, 2V7, 3V5 and 4V5 User s and Installation Manual We Recommend Daily use of Monarch CleanStream TABLE OF CONTENTS Description Page Congratulations...4
More informationProper installation of this product requires the installer to have a good understanding of automotive electronics, systems and procedures.
ENGINEERING COMPANY INC. 51 Winthrop Road Chester, Connecticut 06412-0684 Phone: (860) 526-9504 Fax: (860) 526-4078 Internet: www.whelen.com Sales e-mail: autosale@whelen.com Canadian Sales e-mail: autocan@whelen.com
More informationLAYCOCK SYSTEMS, INC N. 43 rd Street Tampa, FL
LAYCOCK SYSTEMS, INC. 1601 N. 43 rd Street Tampa, FL 33605-5937 LAYCOCK Phone: 813-248-3555, Fax: 813-242-0514 CROWN MOTOR E-Mail: sales@laycocksystems.com MOTOR WINDING Website: www.laycocksystems.com
More informationMODEL 235P INSTALLATION INSTRUCTIONS. Revision B1 Rapid City, SD, USA, 08/2009 II_235P_B1
INSTALLATION INSTRUCTIONS Revision B1 Rapid City, SD, USA, 08/2009 MODEL 235P II_235P_B1 2880 North Plaza Drive, Rapid City, South Dakota 57702 (800) 843-8848 (605) 348-5580 fax (605) 348-5685 BE SURE
More informationA-dec 541 Delivery System and 545 Assistant s Instrumentation
Installation Guide A-dec 541 Delivery System and 545 Assistant s Instrumentation Before You Begin A-dec 545 12 O Clock Assistant s Instrumentation The instructions are the same for installing both the
More informationSPARUS PUMP WITH CONSTANT FLOW TECHNOLOGY
AQUATIC ECO-SYSTEMS SPARUS PUMP WITH CONSTANT FLOW TECHNOLOGY INSTALLATION AND USER S GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS i CUSTOMER SERVICE / TECHNICAL
More informationINSTALLATION INSTRUCTIONS FOR SYMCOM MODEL 231-P-INSIDER
INSTALLATION INSTRUCTIONS FOR SYMCOM MODEL 231-P-INSIDER The PumpSaver Plus Model 231-P-INSIDER fits inside 1/3 1hp, 230V Franklin, Pentek, or CentriPro control boxes. PumpSavers are designed to protect
More informationKit. Hydraulic Kit Installation Guide REV A. Item Component Part Number Qty
Hydraulic Kit Installation Guide Item Component Part Number Qty 1. HOSE ASSY. 3/8" X 110" -8F ORFS X -8F ORFS 90 DEG F451TC-JCJ9080806-110 1 2. HOSE ASSY. 3/8" X 110" -6F ORFS X -8F ORFS 90 DEG F451TC-JCJ9060806-110
More informationINSTRUCTION MANUAL. IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following:
SERIES E Emergency Lighting Equipment IMPTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following: READ AND FOLLOW ALL SAFETY INSTRUCTIONS.
More informationASVC2 OWNER S MANUAL. Vane Cutter PART # MACHINERY DIVISION
A S ASVC2 Vane Cutter PART # 43013 MACHINERY DIVISION OWNER S MANUAL -1- INTRODUCTION The ASVC2 Hollow Vane Cutting Machine was designed utilizing the best current technology to provide greater reliability.
More informationWORKHORSE. Assembly / Operation Instructions / Parts 15 GALLON TRAILER SPRAYER
WORKHORSE S P R A Y E R S Assembly / Operation Instructions / Parts GALLON TRAILER SPRAYER by, a Division of Green Leaf, Inc MODELS #LGSTS & LGDTS GALLON TRAILER SPRAYER Compact Trailer and Tank Polyethylene
More informationPowerMaster MODEL MBG. Installation Manual U L R UL 325 AND UL 991 LISTED MEDIUM DUTY BARRIER GATE OPERATOR TABLE OF CONTENTS
PowerMaster TABLE OF CONTENTS MODEL MBG MEDIUM DUTY BARRIER GATE OPERATOR Important Safety Information...... 3 System Designer Safety Instructions.......4 Installer Safety Instructions....... 5 Installation
More informationInstallation Guide. Enhanced Easy-Stop Trailer ABS 2S/2M, 4S/2M and 4S/3M Premium with PLC Installation Instructions. Hazard Alert Messages
Revised 10-05 Installation Guide Revised 1 Technical 10-05 Bulletin Enhanced Easy-Stop Trailer ABS 2S/2M, 4S/2M and 4S/3M Premium with PLC Installation Instructions Hazard Alert Messages Read and observe
More informationPROFESSIONAL INSTALLATION STRONGLY RECOMMENDED
Installation Instructions CPL Master Module PROFESSIONAL INSTALLATION STRONGLY RECOMMENDED Installation Precautions: Roll down window to avoid locking keys in vehicle during installation Avoid mounting
More informationIMI vibration switch USER MANUAL INSTALLATION - OPERATION - MAINTENANCE
USER MANUAL IMI vibration switch INSTALLATION - OPERATION - MAINTENANCE Z0929039_A ISSUED 03/2017 READ AND UNDERSTAND THIS MANUAL PRIOR TO OPERATING OR SERVICING THIS PRODUCT. contents Overview General
More informationVSPS PACKAGE BOOSTER SYSTEM (END SUCTION PUMP DESIGN) FEATURES T Y P E
PACKAGE BOOSTER SYSTEM (END SUCTION PUMP DESIGN) PACKAGED PUMP SYSTEM WITH CAPACITIES TO 300GPM, PRESSURE BOOST TO 100PSI* WITH UP TO 25HP ON EACH PUMP AVAILABLE IN DUPLEX, AND TRIPLEX CONFIGURATION, AND
More informationMASTERsine Inverter PXA Series Installation Guide
Backup Power System Expert TM MASTERsine Inverter PXA Series Installation Guide Important Safety Instructions IMPORTANT: Read and save this Installation Guide for future reference. This chapter contains
More informationUGE-4K Off-Grid Controller OWNER S MANUAL
UGE-4K Off-Grid Controller OWNER S MANUAL CONTENTS INTRODUCTION... 3 PARTS LIST... 4 SPECIFICATIONS... 5 SAFETY INSTRUCTIONS... 6-7 INSTALLATION... 8 MOUNTING GUIDE... 9 WIRING DIAGRAM... 10 CONTROLLER
More informationGTWY605 Fast Idle, Shift Interlock, I/O Chevy 610 Van - 6.0L and 6.6L Engines Contact InterMotive for additional vehicle applications.
An ISO 9001:2008 Registered Company GTWY605 Fast Idle, Shift Interlock, I/O 2009-2017 Chevy 610 Van - 6.0L and 6.6L Engines Contact InterMotive for additional vehicle applications. Introduction The Gateway
More informationIV. PROOF OF PURCHASE: A warranty claim must be accompanied by proof of the date of purchase.
PD9100 / 9200 SERIES POWER CONVERTER OWNERS MANUAL PROGRESSIVE DYNAMICS, INC. POWER CONVERTER LIMITED WARRANTY I. LIMITED WARRANTY: Progressive Dynamics, Inc. warrants its power converter to be free from
More informationREDUCED DIAMETER SUBMERSIBLE PUMPS
3200 SERIES REDUCED DIAMETER SUBMERSIBLE PUMPS The 3200 Series submersible pumps are designed so that all parts of the pump end, including the cable guard, fall within the diameter of Franklin Electric
More informationZoneEx Modular Wiring System
1 ZoneEx Modular Wiring System ZoneEx is an innovative modular wiring system which offers safer, easier, and efficient solution for electrical installation. The pre-assembled, plug & play Zone Boxes and
More information3 year warranty. (1) Treo Micro fiberglass, gunite fitting, 3/4 PVC. FLED-TM-W-PK10 (10) Treo Micros (WHITE) 80 NEW! Treo Micro fitting adapter
pool lighting The Treo Micro LED light is 12VAC, 2 Watt LED underwater light designed for accent Available in lengths of 30, 50, 80', 150 50,000 hour lamp life No Earth bonding required White or color
More informationA-dec O Clock Delivery System
Installation Guide A-dec 500 12 O Clock Delivery System Before You Begin A-dec 545 12 O Clock Assistant s Instrumentation Before starting the installation: Check with local building and code authorities
More informationMotor Application and Installation Data
Motor Application and Installation Data BMAID INDEX GENERAL INFORMATION Storage, Frequency of Starts, Temperature Ratings, Flow Sleeve... 3-4 CENTRIPRO 4" SUBMERSIBLE MOTOR DATA Motor and Control Box Cross
More information