Surface Wetness Sensor
|
|
- Jayson O’Connor’
- 5 years ago
- Views:
Transcription
1 SKLW 1900 Series Skye Instruments Ltd., 21 Ddole Enterprise Park, Llandrindod Wells, Powys LD1 6DF UK Tel: +44 (0) Iss. 1.2
2 Skye Instruments Ltd. Skye Instruments is based in the UK and we are very proud to be celebrating being in business since Our products are designed and built in the UK. We have a very wide product base and our sensors & systems are used for plant & crop research; micro-climate, global climate change studies; environmental monitoring and controlled environment installations. Products include light sensors & systems, weather monitoring sensors, automatic weather stations, plant research systems, soil and water research systems. Feel free to contact us via our , or any of the methods below: Skye Instruments Skye.Instruments SkyeInstrumentsVideo Skye Instruments Ltd. Click on the icons to browse to the sites, or search for the usernames below. Have a Smartphone? Scan this QR code to access our website for more information about your product: Please be aware that the information in this manual was correct at time of issue, and should be 100% relevant to the accompanying product. We take great pride in our ever-evolving range of products, which means that sometimes the product may change slightly due to re-design. If you have any queries, please do not hesitate to contact our technical team by any of the methods above.
3 CONTENTS Page 1. INTRODUCTION 1 2. OPERATION Sensing Surface Cleaning CONNECTIONS & POWER SUPPLY SKLW 1900 Details SKLW 1902 Details OUTPUTS Voltage Output Current Output Sensitivity Control Connecting to Skye DaaHog...6
4 1. INTRODUCTION The Skye Surface Wetness sensor SKLW 1900 is designed to be precise, easy to use and simple to connect to recording devices and loggers. It is robust and corrosion free, incorporating a sensitive gold plated grid, designed to detect free water on any similarly exposed surface, e.g. leaves, windows, paint surface etc. The sensing grid is excited by AC voltage and droplets of water on this area, however fine, will change the impedance of the sensing grid. These measuring voltages on the sensor surface are very low, and when the sensor is wet they approach zero, thus the sensor is close to being an inert surface. As the electrical properties of natural water vary from place to place and even day to day, an exact calibration of wetness is not possible. As standard the sensor output is nominally mv where 0mV = dry and 400 mv = wet. Other outputs are available at time of ordering, or can be selected on board by the user. Please see later in this manual for details. A sensitivity control is also available, the default factory setting is medium sensitivity, but this can be increased or decreased as preferred by the user. Please see later in this manual for details. The surface wetness sensor is supplied in a weatherproof housing sealed to IP65, which has suitable fixing points for mounting on a flat surface or at any desired angle. Alternatively, it can be used with a mounting arm SKM 226 which enables the sensor to be supported from a mast or boom between 25 and 50 mm diameter. The sensor is stood off from the mast by 330mm with the arm to avoid shadowing effects. 1
5 2. OPERATION 2.1 Sensing Surface The sensing surface attached to the top of the sensor housing is heavily gold plated and surrounded by epoxy resin. If this is kept fairly clean, it will give good, reproducible results. Some users feel that the surface should not be readily wetted by water and to this end a small amount of silicone polish may be applied. Alternatively, to emulate other surfaces such as stone etc., a layer of clean cloth may be used to give a similar wet delay. If experimenting with different coatings on the grid, remember that a waterproof coating will stop the sensor from working. In most applications the plain gold grid will give the best and most consistent results. 2.2 Cleaning It should be noted that to give consistent results, the sensor surface should be consistent itself. Fallout of ash, pollution and smoke particles etc., will affect the performance of the sensor. Depending on the degree of the pollution the sensor must be cleaned with according frequency to prevent build up of such contaminants. Only water and a soft cloth should be used. In extreme cases a little alcohol may help remove some oily deposits but no other solvents nor any abrasive cleaners should be used. Also avoid damage to the silicone rubber cover on the central grid connection. In general, cleaning every 2-4 weeks is all that should be needed in most cases. 2
6 3. CONNECTIONS & POWER SUPPLY (SKLW 1900) The SKLW 1900 Surface wetness sensor requires a D.C. power supply between 5 and 15 volts at a current of about 1.8 ma. If the current output option is used this will rise to approximately 13mA when the sensor is wet. 3.1 Connection Details SKLW 1900 The surface wetness sensor is fitted with a screened 4 core cable with the following connections: WIRE COLOUR FUNCTION Red 5-15 VDC Positive power supply Blue Power supply ground Grey * Analogue output ground and cable screen Green -400 / +400 mv dry / wet switching output Yellow ** mv analogue output ** * Connected internally to blue wire and power supply ground ** If a nominal -2.5 / +2.5 V switching output is preferred, the yellow wire inside the surface wetness housing can be transferred to Pin 6 on the PCB. Please see below for details. 3
7 3.2 Connections & POWER SUPPLY (SKLW 1902) The SKLW 1902 Surface wetness sensor requires a D.C. power supply between 5 and 15 volts at a current of about 1.5 ma. If the current output option is used this will rise to approximately 13mA when the sensor is wet. Connection Details SKLW 1902 The surface wetness sensor is fitted with a screened 4 core cable with the following connections: WIRE COLOUR FUNCTION Red 5-15 VDC Positive power supply Blue Power supply ground Grey cable screen Green 0/2V dry / wet switching output Yellow * Signal/ Analogue Ground * Connected internally to blue wire and power supply ground 4
8 4. OUTPUTS 4.1 Voltage Output The mv analogue output is fairly self explanatory. When the sensing grid is dry, the output is close to but slightly above zero (a baseline of several mv will be clearly seen depending on the sensitivity setting), and rises steadily depending on the amount of water on the sensor to a maximum of about 400mV. The switching output is between approximately -400mV and +400mV (or -2.5Vand +2.5V depending which output is chosen). The output remains at the negative value until the surface is half wet i.e., the analogue output has reached 200mV, then it switch to the positive output and remains thus until the surface dries and the analogue output again falls below 200mV. Please remember that these are units of millivolts only, there can be no precise calibration of wetness as suitable units do not exist Current Output The current switching output is activated by moving the shorting link on the PCB inside the sensor housing, shown as Current Output On/Off in Figure 1 from position OFF to position ON. When this is done, the current in the supply cable (Red / Blue) will be approximately 4mA when the sensor is dry, and will rise abruptly to approximately 13mA when the sensor is wet. The transition from low to high current is made in the same way and at the same points as the switching voltage outputs. When this option is selected the sensor will behave as an Industry standard 4-20 ma transducer that is loop powered (except that the supply range is 5-15 VDC). This current switching output is particularly useful if long lengths of cable are required. Low cost 2-core cable can be used since only the supply (red and blue wires) need be connected. The current output can be measured at the datalogger by inserting a 10 ohm resistor (or similar value) in series with the negative supply to the sensor, and measuring the voltage developed across it. With such a 10 ohm resistor, the output will change from approximately 40mV when dry to approximately 130mV when wet. No other connections need be made to the sensor when the current output is used, but care must be taken to ensure that the supply to the sensor is a minimum of 5 volts, i.e., allowance must be made for the voltage drop across the resistor plus the voltage drop in the cable. Please remember that these are units of millivolts or milliamps only, there can be no precise calibration of wetness as suitable units do not exist. It is advised that if the current output is not required then the jumper is left in the OFF position (factory default position). The voltage outputs will work normally at the same time as the current output but the current consumption will be needlessly high if only the voltage outputs are used. 5
9 4.3 Sensitivity Control There is a sensitivity control on the board which may be set according to local conditions etc. It is shown in Figure 1 as Sensitivity Set. To change it simply pull off the shorting link (pointed pliers may be helpful) and replace it in an alternative position. Keep the orientation as shown in Figure 1. In very polluted rain or fertigation the minimum sensitivity may be best, and in clean areas the maximum sensitivity may be needed. This control simply sets the level of water induced impedance change of the sensing grid that is needed to affect the outputs. Polluted rain will greatly reduce the impedance in small quantities, and pure water much less so. The medium position should be correct for most applications. 4.4 Connecting to Skye DataHog Logger The Skye DataHog2 has two types of voltage inputs, single ended voltage or differential voltage. The surface wetness sensor can be connected to either type. Wiring details are below: SKLW 1900/I The suffix /I denotes the 5 pin Binder connector, wired to give a voltage (mv) output suitable for a single ended voltage socket labeled 0-2V. The Full Scale Value in the DataHog2 should be set to to give a range of 0 to 1 dry to wet. Please remember that these are arbitrary units, there can be no precise calibration of wetness as suitable units do not exist. DATAHOG PLUG FUNCTION WIRE COLOUR Pin 1 5V power supply to sensor Red Pin mv analogue sensor output Yellow Pin 3 No connection ---- Pin 4 No connection ---- Pin 5 Ground Blue & cable screen SKLW 1900/D/I The suffix /D/I denotes the 5 pin Binder connector, wired to give a voltage (mv) output suitable for a differential voltage socket labelled Diff Volts. DATAHOG PLUG FUNCTION WIRE COLOUR Pin 1 5V power supply to sensor Red Pin 2 No connection ---- Pin 3 * Link to Pin Pin mv analogue sensor output Yellow Pin 5 * Ground Blue & cable screen * Pins 3 and 5 are linked in the DataHog plug. 6
SKTS 500 Evapo Sensor
SKTS 500 Evapo Sensor SKYE INSTRUMENTS LIMITED 21, Ddole Enterprise Park Llandrindod Wells Powys, LD1 6DF UK TEL: +44 1597 824811 FAX: +44 1597 824812 General Email: skyemail@skyeinstruments.com Technical
More informationH2B-ACDC H3B-ACDC H5B-ACDC. 1 Channel Current Sensor 2 Channel Current Sensor. 3 Channel Current Sensor 5 Channel Current Sensor
The HXB-ACDC-XX fixed offset, fixed gain series Hall effect current sensor transducer board delivers output voltage proportional to the amount of current detected in the wire being measured. HB-ACDC H2B-ACDC
More informationGeneral Electrical Information
Memorial University of Newfoundland Department of Physics and Physical Oceanography Physics 2055 Laboratory General Electrical Information Breadboards The name breadboard comes from the days when electrical
More informationEFIE Wideband O2 (Electronic Fuel Injector Enhancer) Installation & Operating Instructions.
EFIE Wideband O2 (Electronic Fuel Injector Enhancer) Installation & Operating Instructions. The EFIE is not intended to be a fuel saver by itself. The EFIE is designed to be used in conjunction with fuel
More informationINSTRUCTIONS FOR USE
ROGOWSKI CURRENT TRANSDUCERS INSTRUCTIONS FOR USE RCTi and RCTi-3ph POWER ELECTRONIC MEASUREMENTS Ltd. Gloucester House, Wellington Street, Long Eaton, Nottingham, NG10 4HT, U.K. Tel: +44 115 946 9657
More informationInstallation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor
World Leader in Modular Torque Limiters Installation and Maintenance Instructions PTM-4 Load Monitor 1304 Twin Oaks Street Wichita Falls, Texas 76302 (940) 723-7800 Fax: (940) 723-7888 E-mail: sales@brunelcorp.com
More informationAUTOMATIC VENT CONTROLLER. Operation Manual
AUTOMATIC VENT CONTROLLER EL-VC-AVC002S (Vent System) EL-VC-AVC002P (Vent Pack) EL-VC-AVC002C (Vent Controller) EL-VC-AVC002S+ (Vent System + KeyFob) EL-VC-AVC002P+ (Vent Pack + KeyFob) EL-VC-AVC002C+
More informationB&G Ultrasonic Speed Sensor. Installation and User Manual BGH
B&G Ultrasonic Speed Sensor Installation and User Manual BGH074004-02 1 ULTRASONIC SPEED SENSOR Certification Warnings and Precautions Warning: This equipment generates, uses, and can radiate radio frequency
More informationCARM INTERNATIONAL TOWING MODULES
CARM INTERNATIONAL TOWING MODULES (TA100/200 Instructions Revision = 1) Each Towing Module (if ordered with Loom Pack) is shipped with: A/ These instructions B/ 1 x Towing Control Module C/ 1 x high current
More informationThe platform is placed on the weighing platform using three or four height-adjustable elastomer bearings (EL 120), in order to avoid twisting.
LCS130 2t Description The load cell LCS130 is used in platform-type weighing scales. Three to four load cells support a platform of any size. The output current calibration allows parallel connection of
More informationPortable pressure calibrator, Wally Box III Model CPH7600
Calibration technology Portable pressure calibrator, Wally Box III Model CPH7600 WIKA data sheet CT 17.01 Applications Calibration service companies and service industry Measurement and control laboratories
More informationEL Beam Sensors Standard & SC Versions
EL Beam Sensors Standard & SC Versions 56801399 Copyright 2008 Slope Indicator Company. All Rights Reserved. This equipment should be installed, maintained, and operated by technically qualified personnel.
More informationUSER MANUAL RHF SERIES
Hukseflux Thermal Sensors USER MANUAL RHF SERIES Ring heat flux sensors Copyright by Hukseflux manual v1824 www.hukseflux.com info@hukseflux.com Warning statements Follow the installation instructions
More informationTable of Contents. Introduction 1.1. Applications 1.2. Unpacking and inspection 2.1. Preparing the sensor/transmitter for use 2.2
The phionics STs series sensor/transmitters Table of Contents Section Introduction 1.1 Applications 1.2 Unpacking and inspection 2.1 Preparing the sensor/transmitter for use 2.2 Assembly or disassembly
More informationOPERATING INSTRUCTIONS
OPERATING INSTRUCTIONS Current Transducer January 2012 Case Backup Washer Connection Stem O Ring Stem Seal Fig. 1 - Current Tranducer UNPACKING Page 2 SPECIFICATIONS Page 2 ACQUAINT YOURSELF WITH THE PARTS
More informationPlug in to external instrument, lamp or buzzer
Document release 3.91, September 2014 Gobius, Water and Fuel Tanks, version 3.0 Installation Guide Before you begin 1. Please make sure that no parts are missing. (3 sensors, 1 panel, 1 control unit (091427),
More informationS-SERIES DISPLACEMENT TRANSDUCERS
user manual S-SERIES DISPLACEMENT TRANSDUCERS Index Section Title Page 1.0 Introduction.................. 3 2.0 Installation................... 4 2.1 Mounting the Transducer........ 4 2.2 Cores.......................
More informationMARTINDALE INSTRUCTIONS ELITE FUSE FINDER KIT ELECTRIC. Trusted by professionals. 4.4 Storage Conditions
4.4 Storage Conditions The FD650/R and FD500/T or FD600/T should be kept in warm dry conditions away from direct sources of heat or sunlight, with the battery removed and in such a manner as to preserve
More informationHE-PSU(4.0) Power Supply & Battery Charger Installation, Commissioning & Operating Manual
HE-PSU(4.0) Power Supply & Battery Charger Installation, Commissioning & Operating Manual Page 1 of 10 CONTENTS 1. GENERAL...2 2. POWER REQUIREMENTS...2 2.1 HE-PSU(4.0) Input/Output Electrical Ratings...2
More informationQUASAR ELECTRONICS KIT No WINDSCREEN WIPER CONTROLLER
QUASAR ELECTRONICS KIT No. 1093 WINDSCREEN WIPER CONTROLLER General Description This is a very useful accessory for any car. It can adjust the frequency of operation of the windscreen wipers between once
More informationIn-Place-Inclinometer Installation Manual
Geotechnical Instrumentation In-Place-Inclinometer Installation Manual SDI-12/RS485 Digital Network Device Vertical I-P-I Chain Operations Only Last updated Nov 2013 Keynes Controls In-place-inclinometer
More information2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE
2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE For Diaphragm Dosing Pumps FEM 1.02_.55 / FEM 1.09_.55 Controller board package, without pump: ID 160536 Operating and Installation Manual It is important to
More informationM Series 010.D Data Sheet. Analog Meters with Moving-Coil Movement, 90 Dial PSQ 48 PQ 72 RS PQ 96 RS PQ 144 RS
Data Sheet M Series 010.D.101.11 Analog Meters with Moving-Coil Movement, 90 Dial PSQ 48 PQ 72 RS PQ 96 RS PQ 144 RS Application The moving - coil panel meters PSQ 48 in a housing of moulded thermoplastic
More informationAMS 4711 media-compatible pressure transmitter for industrial applications in matchbox format
There is a general belief that piezoresistive pressure sensors are not suitable for measuring pressure in liquids e.g. for liquid level measurement. Taking the example of pressure transmitter AMS 4711
More informationGobius 1, Level Switch for Water, Fluid & Fuel Tanks
Document release 1.0, September 2013 Gobius 1, Level Switch for Water, Fluid & Fuel Tanks Installation Guide Before you begin 1. Please make sure that no part is missing. (1 sensor, 1 panel, 1 control
More informationM Series 140.D Data Sheet. Two-Point Controller with Moving-Iron or Moving-Coil Movement 90 Dial RW 96 RP 96
Data Sheet M Series 140.D.101.06 RW 96 RP 96 Two-Point Controller with Moving-Iron or Moving-Coil Movement 90 Dial Application The two point controllers RW/RP 96 (M series) with one or two setpoints provide
More informationThe strain sensor is available with integrated electronic evaluator.
Strain Sensor DA68 Description The strain sensor DA68 is suitable for high-resolution detection of forces and deformation of structural works such as bridges, silo legs, offshore wind farms, railway lines,
More informationTABLE OF CONTENTS. Push Button and Rocker Switches Pag. 4. Signal Lights and Lenses Pag. 14. Pressure Switches Pag. 24
1 TABLE OF CONTENTS Push Button and Rocker Switches Pag. 4 Signal Lights and Lenses Pag. 14 Pressure Switches Pag. 24 2 Push button and Rocker Switches 3 Switches Push button SERIES L4 L4 Bowl L4 Rubber
More informationMAGPOWR Spyder-Plus-S1 Tension Control
MAGPOWR TENSION CONTROL MAGPOWR Spyder-Plus-S1 Tension Control Instruction Manual Figure 1 EN MI 850A351 1 A COPYRIGHT All of the information herein is the exclusive proprietary property of Maxcess International,
More information& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL
72-6850 & 72-6852 HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL Table of Contents Introduction 2 Specification 2 Safety 4 EMC 5 Installation 6 Connections 6 Operation 7 Maintenance and Repair 8 www.tenma.com
More informationGS-AQ1000 VOC Indoor Air Quality Sensors
Page 1 of 5 VOC ndoor Air Quality Sensors Features: Benefits: Multi-function sensor Fully configurable LCD Display Direct thermistor temperature options available High stability & reliability Long term
More informationExplanation 1 Input External Switch 2 Input Hipot Safety Switch
on the 1100H+ The 1100H+ has capability, which allows you to set up the tester to control external devices with tester functions. You can also use an input on the tester to start a test. For example, the
More informationEarth-Rite MGV Mobile Grounding Verification. White Paper. Author Details: Page 1 of 5
White Paper Author Details: Mike O Brien, Head of Marketing and Sales for Newson Gale If you have any questions relating to the topics discussed in this article, you can contact Mike directly at: mike.obrien@hoerbiger.com
More informationLOADCELL HANDBOOK. Installation and Set-up manual (HLA N2K) 4 Core Standard Cable
LOADCELL HANDBOOK Installation and Set-up manual (HLA N2K) 4 Core Standard Cable Index 1. Load Cell Installation 2. HLA Amplifier Installation 3. Setting up 4. Specification Fig 1. Standard Load Pin Instillation
More informationColeman Air Diversion Controller Model C40
Coleman Air Diversion Controller Model C40 Version 2.0 With Extended Diversion Mode Designed for 12 volt battery based systems. The Coleman Air model C40 charge controller is a compact, simple to use controller
More informationSingle or Double 240VAC motor control for domestic and industrial gates and doors.
COBO30 Double 240V Motor Drive Controller Features For 240Volt Motors Auto Closing Open Only Security Closing and Extended Lock Pulse (user selectable) Travel Timer Push Button Input Photo Cell Input Option
More informationInstruction Manual PC104/PC105 3-PHASE SOCKET TESTER. Check out what else you can get from Martindale:
Check out what else you can get from Martindale: 17th Edition Testers Accessories Calibration Equipment Continuity Testers Electricians Kits Environmental Products Full Calibration & Repair Service Fuse
More informationMOUNTING, OPERATING, TESTING & MAINTENANCE INSTRUCTIONS FOR ROTEX 3/2 DIRECT ACTING ON/OFF/REGULATING NAMUR SOLENOID VALVE MODEL 30318, 30318LW
Page 1 of 5 MOUNTING, OPERATING, TESTING & MAINTENANCE INSTRUCTIONS FOR ROTEX 3/2 DIRECT ACTING ON/OFF/REGULATING NAMUR SOLENOID VALVE MODEL 30318, 30318LW ROTEX retains all rights to this publication.
More informationAtlas ESR and ESR + Equivalent Series Resistance and Capacitance Meter. Model ESR60/ESR70. Designed and manufactured with pride in the UK.
GB60/70-9 Atlas ESR and ESR + Equivalent Series Resistance and Capacitance Meter Model ESR60/ESR70 Designed and manufactured with pride in the UK User Guide Peak Electronic Design Limited 2004/2016 In
More informationSETRA Operating Instructions Series DPT 230 Pressure Transducers
SETRA Operating Instructions Series DPT 230 Pressure Transducers GENERAL INFORMATION Your Setra Pressure Transducer has been carefully tested and calibrated before shipment. Specific performance information
More informationSM361 RIG SWITCH CONSTRUCTION MANUAL
SM361 RIG SWITCH CONSTRUCTION MANUAL Document ver 1, For software release ver 1.1 May 27, 2016 Controls the power of 12V equipment while a vehicle is in use Product Development by: SM361 RIG SWITCH OVERVIEW
More informationMODEL Nos: CVAC20SS CVAC25SS CVAC30SSR OPERATING & MAINTENANCE INSTRUCTIONS. Distributed by CLARKE International Ltd.
MODEL Nos: CVAC20SS CVAC25SS CVAC30SSR OPERATING & MAINTENANCE INSTRUCTIONS Distributed by CLARKE International Ltd. 1006 Thank you for selecting this VAC KING Stainless Steel Vacuum Cleaner, which will
More informationTRAC-3 TENSION READOUT AND CONTROL
Magnetic Power Systems, Inc. 1626 Manufacturers Drive. Fenton, MO 63026 Tel: 636.343.5550 Fax: 636.326.0608 magpowr@magpowr.com INSTRUCTION MANUAL TRAC-3 READOUT AND CONTROL For Control of Magnetic Particle
More informationVAN DE GRAAFF GENERATORS - 400kV
VAN DE GRAAFF GENERATORS - 400kV EM4133-101 220/240 V.AC. with earth. 50/60 Hz. 300mm diameter ball generates about 400kV DESCRIPTION: The I EC 300mm diameter Van De Graaff Generator is a modern, compact
More informationQUASAR ELECTRONICS KIT No ELECTRONIC CAR IGNITION
QUASAR ELECTRONICS KIT No. 1058 ELECTRONIC CAR IGNITION General Description The advantages of having an electronic ignition in your car are well known. Let us mention them again: 1. Perfect burning of
More informationK25000 & KD25000 Series
K25000 & KD25000 Series Fire Alarm Power Supplies Installation, Commissioning and Operating Manual Man-1128 Issue 14 January 2016 Man-1128_K25400_series_Power_Supply_Manual_14 Page 1 of 20 Section Page
More informationTHE JING ORB. Augmented Therapy System for Rapid Recovery. user manual
THE JING ORB Augmented Therapy System for Rapid Recovery user manual New and Improved This ORB contains our new and greatly improved centerpiece which provides a 50% increase in the field produced. Unlike
More informationProduct manual Oil Streak Sensor INTRODUCTION CONSTRUCTION. Master Sensor
Product manual Oil Streak Sensor INTRODUCTION Oil streak sensors are designed to detect traces of oil travelling through air tubes, down to flows as low as 5mm 3 /min. The product utilizes a master and
More informationElectric amplifiers for proportional valves
Electric amplifiers for proportional valves RE 30109/07.05 1/6 Type VT-VSPA1 Unit series 1X List of contents Contents Page Features 1 Ordering data 2 Preferred types 2 Front panel 3 Circuit diagram 4 Technical
More informationHydro-Wiper A. Data Logger Controlled Anti-Fouling Wiper for the Seapoint Turbidity Meter. Installation and Operation Manual
Hydro-Wiper A Data Logger Controlled Anti-Fouling Wiper for the Seapoint Turbidity Meter Installation and Operation Manual Contents 1. Hydro-Wiper at a glance... 1 Features... 2 2. Hydro-Wiper specifications...
More informationError codes Diagnostic plug Read-out Reset Signal Error codes
Error codes Diagnostic plug Diagnostic plug: 1 = Datalink LED tester (FEN) 3 = activation error codes (TEN) 4 = positive battery terminal (+B) 5 = ground Read-out -Connect LED tester to positive battery
More informationFlex current clamps A 1179 A 1257 A 1395 User Manual Version 1.6; Code No
Flex current clamps A 1179 A 1257 A 1395 User Manual Version 1.6; Code No. 20 751 167 Distributor: Producer: METREL d.d. Ljubljanska 77 SI-1354 Horjul Tel.: +386 1 75 58 200 Fax: +386 1 75 49 226 E-mail:
More informationGeneral Purpose Flasher Circuit
General Purpose Flasher Circuit By David King Background Flashing lights can be found in many locations in our neighbourhoods, from the flashing red light over a stop sign, a yellow warning light located
More informationGobius 1, Level Switch for Water, Fuel and Fluid Tanks, new version 5.0. Installation Guide. Before you begin
Document release, 5.12, July 2017 Gobius 1, Level Switch for Water, Fuel and Fluid Tanks, new version 5.0 Installation Guide Before you begin 1. Please make sure that no part is missing. 1 sensor, 1 panel,
More informationINSTRUCTION MANUAL MARTINDALE CM52 CLAMP METER. ELECTRIC Trusted by professionals. Other products from Martindale:
Other products from Martindale: 18th Edition Testers All-in-one s Calibration Equipment Continuity Testers Electrician s Kits Full Calibration & Repair Service Fuse Finders Digital Clamp Meters Digital
More informationIndex. Index...pag.1. General features...pag.2 Mechanical features Available size. Electrical features pag.3 Protections Signalling Led
MANUAL Micro Driver Via Ilaria Alpi N 6 - zona industriale - Lonato (BS) Tel. 030/9913491r.a. Fax. 030/9913504 http://www.re-elettronica.it E-mail : info@re-elettronica.it Pag. 1 Index Index........pag.1
More informationTHRACIAN METAL DETECTORS
INSTRUCTIONS FOR USE THRACIAN METAL DETECTORS MANUAL GROUND CONTENT Before using your detector for the first time, we strongly recommend that you read this instruction manual carefully un order to make
More informationMODEL 905V OPERATING INSTRUCTIONS
MODEL 905V OPERATING INSTRUCTIONS Quantek Instruments 183 Magill Drive Grafton, MA 01519 Tel: (508) 839-3940 Fax: (508) 819-3444 Email: sales@quantekinstruments.com GENERAL DESCRIPTION These instructions
More informationMPS14 Rack Mount Power Supply
MPS14 Rack Mount Power Supply USER GUIDE Publication AP3898 Limited One Year Warranty This product has been manufactured in the UK by ALLEN & HEATH and is warranted to be free from defects in materials
More informationUser s Manual ENGINE IGNITION ANALYZER. General Technologies Corp.
User s Manual ENGINE IGNITION ANALYZER General Technologies Corp. Table of Contents 1. Safety Rules Page 1 2. Technical Specifications Page 2 2.1 General specifications Page 2 2.2 Electrical specifications
More informationUser's Manual O
11/3/99 3535.ai User's Manual 3535 3535 O Step Motor Drivers Copyright 1998 Applied Motion Products, Inc. 404 Westridge Drive Watsonville, CA 95076 Tel (831) 761-6555 (800) 525-1609 Fax (831) 761-6544
More informationDeep-Water EL Tiltmeter
Deep-Water EL Tiltmeter 56802099 Copyright 2005 Slope Indicator Company. All Rights Reserved. This equipment should be installed, maintained, and operated by technically qualified personnel. Any errors
More informationTHUNDERBIRD. Agricultural Weighing Systems SS1000 Instructions
THUNDERBIRD Agricultural Weighing Systems SS1000 Instructions Installation Locate a weighing site that is well drained. For best weighing results, ensure the weigh bars and weighing platform are on a level
More informationFilters for Compressed Air
Fine Filtration Systems for Industry Product Information Filters for Compressed Air Tel: +49 (0) 6232 24021 Fax: +49 (0) 6232 24025 Email: info@headlinefilters.de Website: www.headlinefilters.de COALESCING
More informationDIAMOND POINT VIBRATING PROBES
DIAMOND POINT VIBRATING PROBES DP130 DP120 DP140 DP150 Instruction Manual Third revision, April 2016 Hycontrol Ltd., Larchwood House, Orchard Street, Redditch, Worcestershire, B98 7DP, U.K. Tel: + 44 (0)1527
More informationDKG-114 MANUAL AND REMOTE START UNIT
DKG-114 MANUAL AND REMOTE START UNIT FEATURES Both manual and remote controlled engine starting and stopping, Automatic shutdown on fault condition, Optional cooldown cycle on remote start operation, Optional
More informationProportional directional valves, pilot operated, with electrical position feedback and integrated electronics (OBE)
Proportional directional valves, pilot operated, with electrical position feedback and integrated electronics (OE) RE 29075/08.13 Replaces: 08.04 1/22 Type 4WRKE Size 10 to 35 Component series 3X Maximum
More informationAutoranging Industrial Multimeter
Owner's Manual Autoranging Industrial Multimeter Model No. 82005 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation
More informationDC POWER SUPPLY ALIMENTATION C.C.
DC POWER SUPPLY ALIMENTATION C.C. ISO-TECH IPS 303A 201-3424 ISO-TECH IPS 601A 201-3446 SAFETY TERMS AND SYMBOLS These terms may appear in this manual or on the product: WARNING. Warning statements identify
More informationAll details within this manual and the catalogue are subject to change without manner.
MOUNTING, OPERATING, TESTING & MAINTENANCE INSTRUCTIONS FOR ROTEX 2/2 INTERNAL PILOT, DIAPHRAGM OPERATED, INLINE, NORMALLY CLOSED SOLENOID VALVE MODEL: 24101, 24101TM, 24102, 24103, 24101V01, 24102V01,
More informationWARNING. This product uses High Brightness LEDs. Direct viewing of the SMD LEDs at close range should be avoided. Keep product away from children.
WARNING Before use please remove the LED Tape from its bag and allow the odour to dissipate in an unused room or outdoor building. Wash Hands after handling. This product uses High Brightness LEDs. Direct
More informationMid-West Instrument. Series 700 "Wet/Wet" Installation and Operating Instructions. Differential Pressure Transmitter
Mid-West Instrument IM_700/A Series 700 "Wet/Wet" Installation and Operating Instructions Differential Pressure Transmitter 6500 Dobry Dr. Sterling Heights, MI USA Toll Free: 800-648-5778 Ph 586-254-6500
More informationPREMIER POWER PACK INSTRUCTION MANUAL EN54-4 POWER SUPPLY UNIT INSTRUCTION MANUAL. GLT.MAN-138 Issue: /05/2016 N.R.P.J.
EN54-4 POWER SUPPLY UNIT INSTRUCTION MANUAL GLT.MAN-138 CONTENTS Introduction to the Premier Power Pack PSU... 2 Changes to EN54-4 (The Fire Alarm Equipment Power Supply Standard)... 3 Indications... 4
More informationGobius 4 for Waste Holding Tanks, new version 5.0
Document release 5.12, July 2017 Gobius 4 for Waste Holding Tanks, new version 5.0 Installation Guide Before you begin 1. Please make sure that no part is missing. 3 sensors, 1 panel, 1 control unit, 1
More informationSPECIALISTS IN PRESSURE, TEMPERATURE, LEVEL, FLOW, GAS DETECTION, CALIBARATION & FLUID POWER INSTRUMENTATION
SPECIALISTS IN PRESSURE, TEMPERATURE, LEVEL, FLOW, GAS DETECTION, CALIBARATION & FLUID POWER INSTRUMENTATION EMAIL: SALES@GMINSTRUMENTATION.CO.UK WEBSITE: WWW.GMINSTRUMENTATION.CO.UK THERMOCOUPLES & PLATINUM
More informationTotal solder points: Difficulty level: beginner advanced 3 DIGIT PANEL METER KIT K2032 ILLUSTRATED ASSEMBLY MANUAL
Total solder points: 65 + 49 Difficulty level: beginner 1 2 3 4 5 advanced 3 DIGIT PANEL METER KIT K2032 Ideal replacement for moving coil meters ILLUSTRATED ASSEMBLY MANUAL H2032IP-1 Features & Specifications
More informationTechnical Data Sheet Sigma Series DS Meter
Technical Data Sheet Sigma Series DS Meter The moving coil panel meters, DS 48/72/96/144 housed in moulded polycarbonate cases are suitable for the measurement of DC currents and voltages. These instruments
More informationMaximum 20 ma, 24 VDC 825 ohms (see section 3.3) Supply voltage dependence
ALPHASENSE USER MANUAL Page 1 4-20mA Transmitter for Oxygen Sensors 072-0126 Issue 2 1 INTRODUCTION The Transmitter PCB includes circuitry for an electrochemical oxygen sensor to convert the µa output
More informationBASIC ELECTRICAL MEASUREMENTS By David Navone
BASIC ELECTRICAL MEASUREMENTS By David Navone Just about every component designed to operate in an automobile was designed to run on a nominal 12 volts. When this voltage, V, is applied across a resistance,
More informationLUDLUM MODEL 133 SERIES GAMMA DETECTOR
LUDLUM MODEL 133 SERIES GAMMA DETECTOR February 2018 Serial Number PR-373191 for Model 133-2 and Serial Number PR-372938 for the remainder of the 133 Series and Succeeding Serial Numbers Manual covers
More informationDycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD
Dycon D1532SM EN50131/PD6662 Grade 3, 12V 2A Power Supply Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD Tel: +44 (0)1443 471 900 Unit A Cwm Cynon Business Park Mountain
More informationOperating Instructions. Pneumatic Control Valve Low Temperature. Type Series GS3
Operating Instructions Pneumatic Control Valve Low Temperature Type 8026 Series GS3 With: Digital Positioner Type 8048 Electro-pneumatic Positioner Type 8047 Pneumatic Positioner Type 8047 Version: 03/2006
More informationPressure Transmitter. Informational & Installation Manual
Pressure Transmitter Informational & Installation Manual February 24, 2011 M374 Rev. E JOWA USA, Inc. 59 Porter Road Littleton, MA 01460 Phone: 978-486-9800 Fax: 978-486-0170 Care and Handling Our submersible
More informationMeasurement of DC resistance; measured at current of 3 Amp. DC (fuses with value below with lower currents)
World's Largest Fuse Measurements Report 01-2010 The measurements done, were made under the aspect of the influence of slow blow fuses on sonic behaviour of high-end audio gear. Measurement of DC resistance;
More informationKM26z 20N; 50N; 100N, 200N, 500N, 1kN, 2kN, 5kN
KM26z 20N; 50N; 100N, 200N, 500N, 1kN, 2kN, Description The load cell KM26z is a membrane-type force sensor with small dimensions. It is suitable for measuring compressive and tensile forces. For force
More informationEXPERIMENTAL VERIFICATION OF INDUCED VOLTAGE SELF- EXCITATION OF A SWITCHED RELUCTANCE GENERATOR
EXPERIMENTAL VERIFICATION OF INDUCED VOLTAGE SELF- EXCITATION OF A SWITCHED RELUCTANCE GENERATOR Velimir Nedic Thomas A. Lipo Wisconsin Power Electronic Research Center University of Wisconsin Madison
More informationReading on meter (set to ohms) when the leads are NOT touching
Industrial Electricity Name Due next week (your lab time) Lab 1: Continuity, Resistance Voltage and Measurements Objectives: Become familiar with the terminology used with the DMM Be able to identify the
More informationWorking Principle of Earth Leakage Circuit Breaker (ELCB) and Residual Current Device (RCD)
Working Principle of Earth Leakage Circuit Breaker (ELCB) and Residual Current Device (RCD) Schneider Electric RCBO Earth Leakage Circuit Breaker (ELCB) An Earth Leakage Circuit Breaker (ELCB) is a device
More informationHIGH VACUUM GAUGE / CONTROLLER - analogue
HIGH VACUUM GAUGE / CONTROLLER - analogue Cat: LB4170-001 (240V.AC. 50/60 Hz) DESCRIPTION : Sensor: LB4171-001 IEC manufactures both analogue and digital electronic High Vacuum gauges and controllers.
More informationCENTRIFLOW METER and ELECTRONICS WIRING and INSTALLATION MANUAL REV 01/16 ORIGINAL LANGUAGE Copyright 2016 Eastern Instrument Laboratories, Inc. All Rights Reserved. TABLE OF CONTENTS SAFETY Safe Operation...
More informationOD 8382 OPTICAL DISSOLVED OXYGEN AUTOCLEAN
UNI EN ISO 9001:2000 CERT. N. 9115 BCEL INSTRUCTION MANUAL OD 8382 OPTICAL DISSOLVED OXYGEN AUTOCLEAN Range: 0/200 % air sat. Power: from OD 7685.110 Option S/N REP N Firmware: R 1.0x Cod. 280168382 Rev.
More informationAD592/592-10K Non-Room Units with a Junction Box, Weatherproof (WP) or Weather Tight (EU) Enclosure
592 Theory of Operation The 592 sensor is a two terminal integrated-circuit temperature sensor. The 592 provides an output current directly proportional to absolute temperature. When the temperature of
More informationP U L S A R point 210
P U L S A R point 210 Page 2 Fourth Edition - Version 1.0 Jan 2014 Copyright Copyright PULSAR Process Measurement Limited 2014. All rights reserved. No part of this publication may be reproduced, transmitted,
More information200 Series Flow Meters
Proteus Industries Inc. 200 Series Flow Meters Technical Reference Manual Can we Improve? Tell our President! Can we improve our product, our support or this manual? We are committed to continuous improvement
More informationDycon D2430 EN54-4 Fire Alarm Power Supply Series
Dycon D2430 EN54-4 Fire Alarm Power Supply Series Technical Description Installation and Operating Manual Construction Product Regulation 0359-CPR-00434 Page 1 of 14 Contents 1. General... 3 1.1 Product
More informationMODEL 12002/12005 GILL MICROVANE & 3-CUP ANEMOMETER MODEL GILL 3-CUP ANEMOMETER MODEL 12302/12305 GILL MICROVANE APRIL 1994
MODEL 12002/12005 GILL MICROVANE & 3-CUP ANEMOMETER MODEL 12102 GILL 3-CUP ANEMOMETER MODEL 12302/12305 GILL MICROVANE APRIL 1994 MANUAL PN 12002/12005-90 R. M. YOUNG COMPANY 2801 AERO PARK DRIVE, TRAVERSE
More informationSelectable ranges and an LCD are a technician s best friend, that s why we make them standard on every dry media differential pressure sensor!
PRESSURE SENSORS PRESSURE PDP3 Series 0-2 32 PDP3 Series 0-10, 0-25 34 PG Gauge Series 36 PW Wet-Wet Series (Cable Version) 38 PW Wet-Wet Series (Conduit Version) 40 PW Series Ordering Guidance 42 Selectable
More informationSMX 22, SMX52 & SMX 102 Installation and Operating Guide
SUPRA Surface Mount Integrated System SMX, SMX5 & SMX Installation and Operating Guide Congratulations! You have purchased a LUMISHORE advanced LED technology underwater lighting system. Every care has
More informationEclipse Solar Suitcase
Eclipse Solar Suitcase Renogy 100W 200W 2775 E. Philadelphia St., Ontario, CA 91761 1-800-330-8678 Version 1.0 Important Safety Instructions Please save these instructions. This manual contains important
More informationGuide to adding a current selection switch to the DIY Portable EVSE from ZCW
Guide to adding a current selection switch to the DIY Portable EVSE from ZCW Introduction This guide is intended for those who have built the Zero Carbon World DIY Charging Station kit as depicted in the
More information