IN-GRADE LTV SERIES. Lightvault NO COMPROMISES NO EXCUSES NO EQUALS BRONZE AND COMPOSITE HOUSING

Size: px
Start display at page:

Download "IN-GRADE LTV SERIES. Lightvault NO COMPROMISES NO EXCUSES NO EQUALS BRONZE AND COMPOSITE HOUSING"

Transcription

1 IN-GRADE LTV SERIES Lightvault C o n c e a l e d I n - g r a d e L u m i n a i r e NO COMOMISES NO EXCUSES NO EQUALS BRONZE AND COMPOSITE HOUSING

2 Lightvault Table of Contents Mechanical Features 4 Trim and Optical Features 5 Product Guide 9 Series Accent 0- LTV70 / LTV0 Series Wall Wash -3 LTV730 / LTV30 Series Accent or Wall Wash 4-5 LTV740 / LTV40 Series Directional Marker 6-7 LTV750 / LTV50 Series Accent or Wall Wash 8- LTV7 LED -3 LTV760 Series Accent 4-5 Options 6-7 LTV766 Remote Transformers 8 Installation Guide 9 Installation Details 30-3 Application Guide 3-33 Photometric Guide 34 Photometrics Safety and Maintenance 47 Lamp Guide KimNOW! 5-Day Shipping Quality On Demand See Ordering Information Pages SITE / AREA PARKING STRUCTURE ROADWAY ARCHITECTURAL FLOOD ACCENT LANDSCAPE MAILING ADDRESS: P.O. BOX CITY OF INDUSTRY, CA BUSINESS ADDRESS: 6555 EAST GALE AVENUE CITY OF INDUSTRY, CA 9745 U.S.A. PHONE 66 / FAX 66 / ENTIRE CONTENTS COPYRIGHT 0 KIM LIGHTING, INC. ALL RIGHTS RESERVED REODUCTION IN WHOLE OR IN PART WITHOUT PERMISSION IS STRICTLY OHIBITED. U.S. PATENTS D40,95 AND D4,640 Printed in U.S.A Version.4 (8/) Lightvault luminaires are designed to be exposed to the most abusive environment of all lighting systems. In-grade components under continuous attack from moisture, caustic fertilizers, soluble minerals, and ultra-violet radiation from HID lamps, are made from a choice of solid bronze or high strength glass reinforced composite. Above-grade components subject to flooding, chemical attack, debris covering the lens, vandalism, and UV bombardment from the sun, are solid heavy cast bronze and double strength glass. Housings and internal components will perform with minimal maintenance; with seals engineered to perform flawlessly, sealing tight after re-lamping. Kim made no compromises in the design of the Lightvault family of products. Because of this, Kim offers no excuses, producing an in-grade family of product with no equals. Lightvault 5 YEAR LIMITED WARRANTY When installed according to Kim Installation Instructions and accepted trade practices, the solid bronze on LTV Series Kim products is warranted for 5 years, from date of sale, against manufacturing defects and failure due to corrosion. All other fixture components (excluding lamps) are warranted to be free of defects in material and workmanship for year from date of sale. During the warranty periods, with proof of purchase, Kim will repair or replace with the same or similar product, at Kim s option, without charge. Labor costs are the owner s responsibility and are excluded from this warranty. This warranty is void if the product is modified, tampered with, misapplied, poorly installed, improperly maintained or subjected to abnormal conditions. Repair or replacement as provided under this warranty is the exclusive remedy of the purchaser. This warranty is in lieu of all other warranties, expressed or implied, including any implied warranty of fitness for the particular application. Kim Lighting shall not be liable to the purchaser for indirect or consequential damages. Lightvault 5/7 YEAR LIMITED WARRANTY When installed according to Kim Installation Instructions and accepted trade practices, the solid bronze trim rings on LTV Series Kim products are warranted for 5 years, and the composite housings are warranted for 7 years, from date of sale, against manufacturing defects and failure due to corrosion. All other fixture components (excluding lamps) are warranted to be free of defects in material and workmanship for year from date of sale. During the warranty periods, with proof of purchase, Kim will repair or replace with the same or similar product, at Kim s option, without charge. Labor costs are the owner s responsibility and are excluded from this warranty. This warranty is void if the product is modified, tampered with, misapplied, poorly installed, improperly maintained or subjected to abnormal conditions. Repair or replacement as provided under this warranty is the exclusive remedy of the purchaser. This warranty is in lieu of all other warranties, expressed or implied, including any implied warranty of fitness for the particular application. Kim Lighting shall not be liable to the purchaser for indirect or consequential damages.

3 KIM LIGHTING

4 Bronze or Exceptional Durability and Value High pivot point for maximum light efficiency when optical system is tilted. Full 3 rotation provided with up to 5 tilt. Positive lock maintains aiming during re-lamping. High performance optical systems include Spot, Narrow Flood, PAR lamp, and Wall Wash distributions. Quick-disconnect allows easy removal of the optical system for access to splice and ballast components. Reverse draft housing provides generous interior space for ease of installation. Flush mounted tempered glass lens, M" thick, slightly crowned for water runoff. Solid heavy cast bronze trim rings with captive stainless steel fasteners. One-piece molded silicone gasket wraps completely around lens flange. Black hi-temp finish gimble ring. Protects composite housing against UV radiation from HID lamps. Stainless steel fasteners used throughout for trouble free maintenance. Anti-siphon barriers used on all wiring passing between electrical compartments. Separate splice compartment does not require potting. Now Available: 8W LED option! Cast aluminum interior covers with silicone gaskets separate optical, ballast and splice compartments. Sealed ballast compartment no potting required. All electrical components mounted to cover for ease of access. The Lightvault provides the ultimate in durability when application conditions demand maximum performance. No other landscape material known is as capable of withstanding extremes like solid cast bronze. 5 YEAR LIMITED WARRANTY The Lightvault shares every feature, internal construction and trim option with the Bronze Housing Lightvault. The high-strength F" thick composite housing produces exceptional durability and value. 5/7 YEAR LIMITED WARRANTY KIM LIGHTING

5 Maximum Flexibility D" Dia. Trim D" Dia. Trim LTV70 Series Accent LTV0 Series Accent LTV70 Series Wall Wash LTV0 Series Wall Wash D" Dia. Trim D" Dia. Trim 3 or Distribution available LTV730 Series Accent or Wall Wash LTV30 Series Accent or Wall Wash LTV740 Series Directional Marker LTV40 Series Directional Marker 9" Dia. Trim 6" Dia. Trim Flat Lens 9" Dia. Trim LTV760 Series Die-Cast Brass Accent LTV769 Series Die-Cast Brass Accent 6" Dia. Trim Eyeball Trim LTV750 Series Accent or Wall Wash LTV50 Series Accent or Wall Wash LTV767 Series Die-Cast Brass Accent LTV768 Series Die-Cast Brass Accent 9" Dia. Trim LTV7 Cast Accent KIM LIGHTING 3

6 Mechanical Features Positive Repeatable Lens S e a l : Robust best describes the LTV lens seal. The lens is flush mounted to the lens frame for water runoff, and surrounded by a one-piece silicone gasket. Eight large captive M" stainless steel hex socket cap screws provide enormous gasket compression. Water Runoff Lightvault : Debris and moisture are not trapped to fall into the fixture when the lens frame is removed. Others: Trapped debris and moisture fall into the fixture when the lens frame is removed. Cast Bronze and Stainless Steel Lens Rings: There are only certain materials that will withstand the constant moisture, soil chemical and UV bombardment (see below) that in-grade fixtures must endure. That is why LTV lens rings are available as cast bronze or stainless steel. The bronze material will also weather to a deep bronze color that blends with foliage and paving materials. Special Composite features: The body and ballast module are compression molded in high temperature, fiberglass impregnated composite, epoxy bonded to form a single reverse draft housing. Captive brass inserts are molded into the body to receive the M" stainless steel cap screws in the lens frame, and two L" NPT conduit taps are provided in the splice compartment. Total UV Protection: The composite housing, while unaffected by soil chemicals and moisture, is subject to UV degradation as are all plastics. In addition to the cast bronze lens frame which protects the housing top from sunlight, an internal UV guard shields the housing interior against UV radiation from HID lamps. For applications where the housing may be partially exposed, the bronze housing is unaffected. Reverse Draft Housing: To prevent the housing from uplifting in certain soil conditions, a reverse draft configuration is used. With the upper housing bottom larger than the top, a natural grip holds the fixture in place. This also provides greater interior volume for ease of wiring the fixture during installation. UV UV UV Shield Others Lightvault Uplift ±5 aiming () Anti-siphon Barriers: All wires entering and leaving the ballast compartment pass through anti-siphon barriers. This prevents any moisture from seeping into the ballast area around wiring, or siphoning through the insulation and between the conductors. The anti-siphon barrier is a one-piece molded and threaded plug installed at the factory. 4 KIM LIGHTING

7 Trim and Optical Features LTV70 / LTV0 LTV / LTV50-54 LTV760 / LTV60 LTV7. Optical Adjustment up to ±5 Tilt; 3 Rotation Spot or Narrow Flood A. C. LTV730 / LTV30 LTV / LTV Optical Adjustment up to ±5 Tilt; 3 Rotation B. C. LTV740 / LTV40-3 LTV740H / LTV40H - Optical Adjustment 3 Rotation LED emitters LTV767 LTV768 LTV7 D. Three Top Configurations:. Flush lens, slightly crowned for water runoff, suitable for all in-grade applications. Half Shield or Rock Guard options available.. Fully rotatable eyeball configuration for applications requiring additional lamp tilt. 3. Directional Marker for driveover or perimeter installation in drives or pathways. Three Optical Systems: A. Spot or Narrow Flood specular s for ED-7 medium base HID lamps. Mounting brackets allow 3 rotation and ±5 vertical adjustment, with locking screws to insure aiming is secure during re-lamping. Black arc tube glare shield included with spot to restrict unwanted spill light. B. medium base socket for HID or halogen lamps. Mounting brackets allow 3 rotation and ±5 vertical adjustment, with locking screws to insure aiming is secure during re-lamping. C. Wall Wash, a one-piece hydroformed specifically engineered for vertical surface lighting. Black louver shield controls glare towards the viewer. Fully rotatable 3 with locking screws provided. D. LED, 6W to 8W. 3 Rotation Lightvault Optical Aiming Range: The vertical orientation of the and LTV / LTV50-54 Series is complimented by the fixed tilt from vertical of the LTV730 / LTV30 and LTV / LTV55-58 ( eyeball trim). This provides a total aiming range of up to for the product line. KIM LIGHTING 5

8 Applications When conditions demand ultimate durability. 70 years experience in Landscape Lighting and 48 years of in-grade experience are incorporated into every Kim Lightvault product. A commitment to producing the most durable product possible is the core of the bronze Lightvault series. While composite products are proving to be very durable, bronze has been used for centuries in the widest range of environments imaginable, and has proven to be almost indestructible. In applications anticipated to remain in service over decades, bronze stands on a well-deserved reputation for durability. For poured-in-place concrete or cut stone: In these applications, failure of the fixture for any reason may result in damage that may not be repairable. Matching stone, brick, or marble that has aged can be virtually impossible. Using solid bronze housings provides additional assurance that stone work will remain undisturbed. Installations with exposed fixture housing: Slopes or changes in terrain expose the fixture housing to sunlight and UV radiation. Over time, this will degrade composite fixture integrity. The Bronze housing will also withstand impacts by landscape maintenance equipment. When integrated into architectural features: Integration of lighting fixtures into monumental structures can be problematic. The fixture housings may be exposed to higher stress or exposed to damage from vandalism. Solid bronze construction assures these fixtures will last for decades without loss of integrity. Where durability is of paramount concern: Servicing in-grade housings in paved areas can be virtually impossible. These applications may expose in-grade fixtures to extreme stress. The extra durability of solid bronze will stand up to the most abusive of applications. 6 KIM LIGHTING

9 Three Sizes Bronze or L" (9. mm) 6J" (4.8 mm) D" DIA. (95.3 mm) D" DIA. (95.3 mm) L" (9. mm) E" (30.6 mm 3B" (79.4 mm) D" DIA. (95.3 mm) LTV70 / LTV0 D" DIA. (95.3 mm) D" Diameter Trim: Bronze Composite LTV70 Series LTV0 Series: Flat Lens Accent Light LTV70 Series LTV0 Series: Flat Lens Wall Wash LTV730 Series LTV30 Series: Eyeball Trim Accent and Wall Wash LTV740 Series LTV40 Series: Directional Marker Incandescent / Halogen: Up to 50W, T-4 Mini-can Low Voltage: Up to 00W, V, PAR36 or AR HID: Up to 75W MH/HPS,, ED-7 Options: HS0 Half Shield TR0 Trim Ring 4J" (08.0 mm) E" (30.6 mm) LTV730 / LTV30 6J" (4.8 mm) LTV740 / LTV40 RG0 Rock Guard SS0 Stainless Steel Lens Ring GM0 GM30 Grout Mask (TR0 Trim Ring included) L" (9. mm) 9" DIA. (8.6 mm) 3E" (97.8 mm) 3M" (84. mm) 9" DIA. (8.6 mm) 9" Diameter Trim: Bronze Composite LTV Series LTV50-54 Series: Flat Lens Accent and Wall Wash LTV Series LTV55-59 Series: Eyeball Trim Accent and Wall Wash LTV7: LED Cluster L" (33.9 mm) LTV LTV50-54 L" (33.9 mm) LTV LTV55-59 Incandescent / Halogen: Up to 50W,, T-4 Mini-can Low Voltage: Up to 00W, V, PAR36 or AR H.I.D.: Up to 70W MH/HPS, or ED-7 LED: 8 Watt Options: HS50 Half Shield *TR50 Trim Ring L" (9. mm) 8L" (.3 mm) 9" Dia. (8.6 mm) LTV 7 - LED RG50 Rock Guard SS50 Stainless Steel Lens Ring *GM50 Grout Mask (TR50 Trim Ring included) * TR50 and GM50 not available on LTV7 6" Diameter Trim: 9 3" (5. mm) 6" DIA. (5.4 mm) 9 3" (5. mm) 6" DIA. (5.4 mm) Die-Cast Brass only LTV760 Series: Flat Lens Accent 7 3" (78. mm) LTV760 In-grade 5 7 3" (40.5 mm) LTV760 In-grade or Surface Incandescent / Halogen: Up to 50W PAR0 Low Voltage: Up to 75W, V, MR6 LED: 5-5 Watt Options: HS60 Half Shield SS60 Stainless Steel Lens Ring RG60 Rock Guard TR60 Trim Ring KIM LIGHTING 7

10 8 KIM LIGHTING LTV740 / LTV40 Series Directional Marker

11 Product Guide LTV70 Series LTV0 Series 70-50W PMH, 75W MH 70-50W HPS 4W PL 50HAL LTV70 Series LTV0 Series 70-50W PMH, 75W MH 70-50W HPS 3W PL 50W HAL LTV730 Series LTV30 Series 70-50W PMH, 75W MH 70-50W HPS 6W & 3W PL 50HAL LTV740 Series LTV40 Series 70-00W PMH 70-00W HPS 0W HAL 4W PL page 0 page page 4 page 6 Architectural Trees Accent Drive-over durable up to 5,500 lb vehicles. Signs Facades Drive-over durable up to 5,500 lb vehicles. Architectural Trees Signs Facades Accent LTV730 / LTV30 series fixtures are designed for applications requiring additional lamp tilt. Greater fixture setback from the lighted object is allowed, producing a flatter lighting effect, similar to floodlighting. Drive-over Perimeter Marker Marker Drive-over durable up to 0,000 lb vehicles, up to 5 mph. LTV750 Series LTV50 Series page W PMH 50-70W HPS 6W & 3W PL 0W & 50W HAL 00W LV Architectural Trees Accent Drive-over durable up to 5,500 lb vehicles. Signs Facades LTV750 Series LTV50 Series 50-70W PMH 50-70W HPS 6W & 3W PL 0W & 50W HAL 00W LV LTV7 8W (8 LED emitters) page 0 page Architectural Trees Signs Facades Accent LTV755 / LTV55 series fixtures are designed for applications requiring additional lamp tilt. Greater fixture setback from the lighted object is allowed, producing a flatter lighting effect, similar to floodlighting. Architectural Accent Trees LTV760 Series Die-Cast Brass Housing 50W HAL 50-75W LV 5-5W LED 0W & 35W PMH page 4 Architectural Accent Trees Signs Facades KIM LIGHTING 9

12 Specifications LTV70 Series Accent LTV0 Series Accent Lens Ring: One-piece cast bronze, natural finish. (Optional standard Stainless Steel lens ring is also available.) Eight captive M" blackened stainless steel hex-socket cap screws. Lens: Clear tempered borosilicate glass, M" thick, flush with lens ring, slightly crowned. Lens Gasket: One-piece molded silicone, U-channel wraps completely around lens flange. : Two-piece cast bronze, F" min. wall thickness upper and lower housing continuously soldered together. No top lip to trap dirt and moisture. Separate splice and ballast compartments, individual cast aluminum internal covers with one-piece molded silicone gaskets. Two L" NPT in bottom of 33 cu in. splice area. Modular reverse draft housing design (top smaller than largest bottom diameter). : High temperature, compression molded, fiberglass impregnated, F" min. wall composite. Charcoal gray. No top lip to trap dirt and moisture. Solid brass knurled inserts molded-in to receive lens ring screws. Separate splice and ballast compartments, individual cast aluminum internal covers, with silicone gaskets. Two L" NPT in bottom, 33 cu in. splice area. Modular reverse draft design (top dia. smaller than bottom), body and ballast modules epoxy bonded. Optical System: and NF - Spot or Narrow Flood spun aluminum s, specular Alzak, black Duranodic arc tube glare shield on only. (G base socket option available.) - for lamps. All sockets 4KV medium base. All optical systems yoke mounted, 3 rotation, ±5 vertical adjustment, locking screws, black hi-temp finish gimble ring. Electrical Module: High power factor ballast, -F starting, factory mounted and prewired to gasketed compartment cover, only. Wiring: Anti-siphon barriers on all wiring to and from ballast compartment. All components wire linked for ground, quick-disconnect for removal of optical system., NF, or OPTICAL SYSTEM D" DIA. (95.3 mm) Architectural Accent Trees 3 Listings and Ratings UL cul 598 IP68 Rated CE 5C Ambient Drive-over Durability: When installed in concrete (see page 9), fixture will withstand drive-over by vehicles weighing up to 5,500 lb. 6J" (4.8 mm) L" (9. mm) 3J" (336.6 mm) Optical Adjustment 5 5 B" (54.0 mm) 3K" (88.9 mm) Suitable for wet recessed L" DIA. (33.9 mm) 3" (76. mm) () L" NPT 0 KIM LIGHTING

13 Ordering Example: LTV70 / / 70PMH0 / HS0 / TR0 Fixture Optics Lamp Mode Options Ordering Information Fixture Optics Lamp Mode Options (See pages 6-7) LTV70 HID Accent LTV0 HID Accent LTV7 Halogen Accent LTV Halogen Accent Spot NF Narrow Flood Yoke mounted and medium base socket for ED-7 HID lamp. PAR Lamp Yoke mounted medium base socket for halogen lamp. Lamps by others - see pages for lamp guide. PAR Lamp Yoke mounted medium base socket for HID lamp. Pulse Start 70PMH0 70PMH08 70PMH40 70PMH77 70PMH347 00PMH0 00PMH08 00PMH40 00PMH77 00PMH347 50PMH0 50PMH08 50PMH40 50PMH77 50PMH347 High Pressure Sodium 70HPS0 70HPS08 70HPS40 70HPS77 70HPS347 00HPS0 00HPS08 00HPS40 00HPS77 00HPS347 50HPS0 50HPS08 50HPS40 50HPS77 50HPS347 50HAL0 50W maximum, lower wattage lamps may be used. Compact Fluorescent 4PL0 4PL08 4PL40 4PL77 HPS and PL not available for Optics. NOTE: Due to the Energy Independence and Security Act (EISA) of 007, Kim Lighting can no longer supply probe start metal halide ballasts with its luminaires, effective January, 009. Contact Kim Lighting for availability of replacement ballasts for warranty service claims. (Visit or the Library of Congress website for more details). KimNOW! Available Configurations: KN-LTV0/50PMH*, KN-LTV0NF/50PMH* Accessories: KN-GM0, KN-HS0, KN-RG0, KN-TR0 * Multi-tap ballast (0, 08, 40, or 77 volts) G Base Socket available for 70W and 50W Pulse Start T-6 Bi-pin lamps. HS0 Half Shield lens ring, cast bronze. TR0 Trim Ring for flush mounting in concrete, brass. GM0 Grout Mask for fixture support during concrete pour, galvanized steel. TR0 Trim Ring Included. Hex Cell Louver 3 HL0 Installs behind main lens. (See page 7) Prismatic Lens 4 Spread Lens 4 RG0 Rock Guard lens ring, cast bronze. SS0 Brushed Stainless Steel Lens Ring PL0 Installs behind main lens. (See page 7) SL0 Installs behind main lens. (See page 7) 3 Not for use with PL0 or SL0 lenses. 4 Not for use with HL0 Louver. 70 PMH 0 Line Volts Lamp Type: PMH = Pulse Start HPS = High Pressure Sodium HAL = Halogen PL = Compact Fluorescent Lamp Watts KIM LIGHTING

14 Specifications LTV70 Series Wall Wash LTV0 Series Wall Wash OPTICAL SYSTEM D" DIA. (95.3 mm) Lens Ring: One-piece cast bronze, natural finish. (Optional standard Stainless Steel lens ring is also available.) Eight captive M" blackened stainless steel hex-socket cap screws. Lens: Clear tempered borosilicate glass, M" thick, flush with lens ring, slightly crowned. Lens Gasket: One-piece molded silicone, U-channel wraps completely around lens flange. : Two-piece cast bronze, F" min. wall thickness upper and lower housing continuously soldered together. No top lip to trap dirt and moisture. Separate splice and ballast compartments, individual cast aluminum internal covers with one-piece molded silicone gaskets. Two L" NPT in bottom of 33 cu in. splice area. Modular reverse draft housing design (top smaller than largest bottom diameter). : High temperature, compression molded, fiberglass impregnated, F" min. wall composite. Charcoal gray. No top lip to trap dirt and moisture. Solid brass knurled inserts molded-in to receive lens ring screws. Separate splice and ballast compartments, individual cast aluminum internal covers, with silicone gaskets. Two L" NPT in bottom, 33 cu in. splice area. Modular reverse draft design (top dia. smaller than bottom), body and ballast modules epoxy bonded. Optical System: - one-piece hydroformed, specular Alzak, black lower shield towards viewers, 3 rotation and screw locks, Wall Wash distribution. Medium base 4KV socket for HID lamps. (G base socket option available.) Mini-can socket for halogen lamps. Electrical Module: High power factor ballast, -F starting, factory mounted and prewired to gasketed compartment cover, LTV7 / LTV only. Wiring: Anti-siphon barriers on all wiring to and from ballast compartment. All components wire linked for ground, quick-disconnect for removal of optical system. Signs Facades Listings and Ratings UL cul 598 IP68 Rated CE 5C Ambient Suitable for wet recessed Drive-over Durability: When installed in concrete (see page 9), fixture will withstand drive-over by vehicles weighing up to 5,500 lb. L" (9. mm) 3 Optical Adjustment 3K" (88.9 mm) E" (30.6 mm) 8E" (5.4 mm) 3" (76. mm) () L" NPT B" (54.0 mm) L" DIA. (33.9 mm) KIM LIGHTING

15 Ordering Example: LTV7 / / 70PMH77 / HS0 / GM30 Fixture Optics Lamp Mode Options Ordering Information Fixture Optics Lamp Mode Options (See pages 6-7) LTV7 HID Wall Wash LTV HID Wall Wash Wall Wash Hydroformed and medium base socket for ED-7 HID lamp. Pulse Start 70PMH0 70PMH08 70PMH40 70PMH77 70PMH347 00PMH0 00PMH08 00PMH40 00PMH77 00PMH347 50PMH0 50PMH08 50PMH40 50PMH77 50PMH347 High Pressure Sodium 70HPS0 70HPS08 70HPS40 70HPS77 70HPS347 00HPS0 00HPS08 00HPS40 00HPS77 00HPS347 50HPS0 50HPS08 50HPS40 50HPS77 50HPS347 Compact Fluorescent 3PL0 3PL08 3PL40 3PL77 G Base Socket available for 70W and 50 W Pulse Start T-6 Bi-pin lamps. HS0 Half Shield lens ring, cast bronze. RG0 Rock Guard lens ring, cast bronze. NOTE: Use of Rock Guard (RG0) will cast shadows on lighted surfaces with clear lamp. Use coated lamp. See page 6 for more information. SS0 Brushed Stainless Steel Lens Ring LTV73 Halogen Wall Wash LTV3 Halogen Wall Wash Wall Wash Hydroformed and socket for T-4 halogen mini-can lamp. 50HAL0 50W maximum, lower wattage lamps may be used. TR0 Trim Ring for flush mounting in concrete, brass. GM30 Grout Mask for fixture support during concrete pour, galvanized steel. TR0 Trim Ring Included. NOTE: Due to the Energy Independence and Security Act (EISA) of 007, Kim Lighting can no longer supply probe start metal halide ballasts with its luminaires, effective January, 009. Contact Kim Lighting for availability of replacement ballasts for warranty service claims. (Visit or the Library of Congress website for more details). Lamps by others - see pages for lamp guide. KimNOW! Available Configurations: KN-LTV/50PMH*, Accessories: KN-GM30, KN-HS0, KN-RG0, KN-TR0 * Multi-tap ballast (0, 08, 40, or 77 volts) 70PMH77 Line Volts Lamp Type: PMH = Pulse Start HPS = High Pressure Sodium HAL = Halogen PL = Compact Fluorescent Lamp Watts KIM LIGHTING 3

16 Specifications LTV730 Series Accent or Wall Wash LTV30 Series Accent or Wall Wash, NF, or OPTICAL SYSTEM Architectural Accent Trees OPTICAL SYSTEM Signs Facades 4J" (08.0 mm) 3K" (88.9 mm) 3 5 D" DIA. (95.3 mm) Optical Adjustment 5 3K" (88.9 mm) Eyeball Retaining Ring: Cast bronze, natural finish. Eight captive M" blackened stainless steel hexsocket cap screws. Eyeball: Cast bronze, natural finish. 3 rotation within retaining ring. Holds optical assemblies at from vertical. Lens Ring: Cast bronze, natural finish, beveled for water runoff. Four captive J" blackened stainless steel hex-socket cap screws. Lens: Clear tempered flat glass, F" thick. Lens Gasket: One-piece molded silicone, U-channel wraps completely around lens edge. : Two-piece cast bronze, F" min. wall thickness upper and lower housing continuously soldered together. No top lip to trap dirt and moisture. Separate splice and ballast compartments, individual cast aluminum internal covers with one-piece molded silicone gaskets. Two L" NPT in bottom of 33 cu in. splice area. Modular reverse draft housing design (top smaller than largest bottom diameter). : High temperature, compression molded, fiberglass impregnated, F" min. wall composite. Charcoal gray. No top lip to trap dirt and moisture. Solid brass knurled inserts molded-in to receive retaining ring screws. Separate splice and ballast compartments, individual cast aluminum internal covers, with silicone gaskets. Two L" NPT in bottom, 33 cu in. splice area. Modular reverse draft design (top dia. smaller than bottom), body and ballast modules epoxy bonded. Optical System: and NF - Spot or Narrow Flood spun aluminum s, specular Alzak, black Duranodic arc tube glare shield on only. (G base socket option available.) - for lamps. All optical systems yoke mounted, 3 rotation, ±5 vertical adjustment (5 to 45 from 0 vertical), locking screws, black hi-temp finish gimble ring. - one-piece hydroformed, specular Alzak, 3 rotation and screw locks, Wall Wash distribution. All medium base sockets rated 4KV. (G base socket option available.) Mini-can socket for halogen lamps. Electrical Module: High power factor ballast, -F starting, factory mounted to gasketed compartment cover, LTV730 / LTV30 and LTV73 / LTV3 only. Wiring: Anti-siphon barriers on all wiring to and from ballast compartment. All components wire linked for ground, quick-disconnect for removal of optical system. Listings and Ratings UL cul 598 IP68 Rated CE 5C Ambient Suitable for wet recessed LTV730 / LTV30 series fixtures are designed for applications requiring additional lamp tilt. Greater fixture setback from the lighted object is allowed, producing a flatter lighting effect. 8E" (5.4 mm) E" (30.6 mm) 3" (76. mm) () L" NPT B" (54.0 mm) L" DIA. (33.9 mm) 4 KIM LIGHTING

17 Ordering Example: LTV73 / / 50HPS77 / GM30 Fixture Optics Lamp Mode Options Ordering Information Fixture Optics Lamp Mode Options (See pages 6-7) LTV730 HID Accent LTV30 HID Accent Spot NF Narrow Flood Yoke mounted and medium base socket for ED-7 HID lamp. PAR Lamp Yoke mounted medium base socket for HID lamp. HPS and PL not available for Optics. Pulse Start 70PMH0 70PMH08 70PMH40 70PMH77 70PMH347 00PMH0 00PMH08 00PMH40 00PMH77 00PMH347 50PMH0 50PMH08 50PMH40 50PMH77 50PMH347 High Pressure Sodium 70HPS0 70HPS08 70HPS40 70HPS77 70HPS347 00HPS0 00HPS08 00HPS40 00HPS77 00HPS347 50HPS0 50HPS08 50HPS40 50HPS77 50HPS347 Compact Fluorescent 3PL0 3PL08 3PL40 3PL77 G Base Socket available for 70W and 50W Pulse Start T-6 Bi-pin lamps. TR0 Trim Ring for flush mounting in concrete, brass. GM30 Grout Mask for fixture support during concrete pour, galvanized steel. TR0 Trim Ring Included. LTV73 Halogen Accent LTV3 Halogen Accent PAR Lamp Yoke mounted medium base socket for halogen lamp. 50HAL0 50W maximum, lower wattage lamps may be used. Hex Cell Louver 3,4 HL30 Installs behind main lens. (See page 7) Prismatic Lens 5 PL30 Installs behind main lens. (See page 7) LTV73 HID Wall Wash LTV3 HID Wall Wash Wall Wash Hydroformed and medium base socket for ED-7 HID lamp. Pulse Start 70PMH0 70PMH08 70PMH40 70PMH77 70PMH347 00PMH0 00PMH08 00PMH40 00PMH77 00PMH347 50PMH0 50PMH08 50PMH40 50PMH77 50PMH347 High Pressure Sodium 70HPS0 70HPS08 70HPS40 70HPS77 70HPS347 00HPS0 00HPS08 00HPS40 00HPS77 00HPS347 50HPS0 50HPS08 50HPS40 50HPS77 50HPS347 Compact Fluorescent 6PL0 6PL08 6PL40 6PL77 Spread Lens 5 SL30 Installs behind main lens. (See page 7) 3 Not for use with LTV73 / LTV3 or LTV733 / LTV33 optical systems. 4 Not for use with PL30 or SL30 lenses. 5 Not for use with HL30 louver. 50HPS77 Line Volts Lamp Type: PMH = Pulse Start LTV733 Halogen Wall Wash Wall Wash 50HAL0 50W maximum, lower wattage lamps may be used. HPS = High Pressure Sodium HAL = Halogen PL = Compact Fluorescent Lamp Watts LTV33 Halogen Wall Wash Hydroformed and socket for T-4 halogen mini-can lamp. NOTE: Due to the Energy Independence and Security Act (EISA) of 007, Kim Lighting can no longer supply probe start metal halide ballasts with its luminaires, effective January, 009. Contact Kim Lighting for availability of replacement ballasts for warranty service claims. (Visit or the Library of Congress website for more details). Lamps by others - see pages for lamp guide. KIM LIGHTING 5

18 Specifications LTV740 Series Directional Marker LTV40 Series Directional Marker Dome: One-piece cast bronze, natural finish, horizontal louver and domed top supported by eight vertical ribs. Polished stainless steel redirects light horizontally. Eight captive M" blackened stainless steel hex-socket cap screws. Lens: Clear tempered borosilicate glass, M" thick, flush with lens ring flange, slightly crowned. Lens Gasket: One-piece molded silicone, U-channel wraps completely around lens flange. : Two-piece cast bronze, F" min. wall thickness upper and lower housing continuously soldered together. No top lip to trap dirt and moisture. Separate splice and ballast compartments, individual cast aluminum internal covers with one-piece molded silicone gaskets. Two L" NPT in bottom of 33 cu in. splice area. Modular reverse draft housing design (top smaller than largest bottom diameter). : High temperature, compression molded, fiberglass impregnated, F" min. wall composite. Charcoal gray. No top lip to trap dirt and moisture. Solid brass knurled inserts molded-in to receive lens ring screws. Separate splice and ballast compartments, individual cast aluminum internal covers, with silicone gaskets. Two L" NPT in bottom, 33 cu in. splice area. Modular reverse draft design (top dia. smaller than bottom), body and ballast modules epoxy bonded. Optical System: - Spot spun aluminum, specular Alzak, black Duranodic arc tube glare shield. (G base socket option available.) - for lamps. All sockets 4KV medium base. All optical systems yoke mounted (adjustments to be set vertical for optimum performance). Black hi-temp finish gimble ring. Electrical Module: High power factor ballast, -F starting, factory mounted and prewired to gasketed compartment cover, LTV740 / LTV40 only. Wiring: Anti-siphon barriers on all wiring to and from ballast compartment. All components wire linked for ground, quick-disconnect for removal of optical system. or OPTICAL SYSTEM Driveover Marker Perimeter Marker D" DIA. (95.3 mm) D" DIA. (95.3 mm) Drive-over Durability: The LTV740 / LTV40, properly installed with the TR0 Trim Ring, and in concrete (see page 9), fixture will withstand drive-over traffic of 0,000 lb vehicles travelling up to 5 mph. 45 6J" (4.8 mm) Cutoff Angle 3B" (79.4 mm) 3J" (336.6 mm) 3 C" (60.3 mm) B" (54.0 mm) Listings and Ratings UL cul 598 IP68 Rated CE 5C Ambient Suitable for wet recessed 3K" (88.9 mm) L" DIA. (33.9 mm) 3" (76.mm) () L" NPT 6 KIM LIGHTING

19 Ordering Example: LTV740 / / 70PMH77 / GM0 Fixture Optics Lamp Mode Options Ordering Information Fixture Optics Lamp Mode Options (See pages 6-7) LTV740 3 HID Directional Marker LTV40 3 HID Directional Marker LTV740H HID Directional Marker LTV40H HID Directional Marker LTV74 3 Halogen Directional Marker 3 3 Spot Yoke mounted and medium base socket for ED-7 HID lamp. Spot Yoke mounted and medium base socket for ED-7 HID lamp. PAR Lamp Pulse Start 70PMH0 70PMH08 70PMH40 70PMH77 70PMH347 70HPS0 70HPS08 70HPS40 70HPS77 70HPS347 00PMH0 00HPS0 00PMH08 00HPS08 00PMH40 00HPS40 00PMH77 00HPS77 00PMH347 00HPS347 Pulse Start 70PMH0 70PMH08 70PMH40 70PMH77 70PMH347 High Pressure Sodium High Pressure Sodium 70HPS0 70HPS08 70HPS40 70HPS77 70HPS347 00PMH0 00HPS0 00PMH08 00HPS08 00PMH40 00HPS40 00PMH77 00HPS77 00PMH347 00HPS347 0HAL0 0W maximum, lower wattage lamps may be used. Compact Fluorescent 4PL0 4PL08 4PL40 4PL77 Compact Fluorescent 4PL0 4PL08 4PL40 4PL77 G Base Socket available for 70W Pulse Start T-6 Bi-pin lamps. TR0 Trim Ring for flush mounting in concrete, brass. GM0 Grout Mask for fixture support during concrete pour, galvanized steel. TR0 Trim Ring Included. Highly recommended to optimize light grazing effect and drive-over durability. Hex Cell Louver HL0 Installs behind main lens. (See page 7) LTV4 3 Halogen Directional Marker Yoke mounted medium base socket for halogen lamp. LTV74H Halogen Directional Marker PAR Lamp 0HAL0 0W maximum, lower wattage lamps may be used. LTV4H Halogen Directional Marker Yoke mounted medium base socket for halogen lamp. Lamps by others - see pages for lamp guide. 70PMH77 Line Volts Lamp Type: PMH = Pulse Start HPS = High Pressure Sodium HAL = Halogen PL = Compact Fluorescent Lamp Watts KIM LIGHTING 7

20 Specifications LTV750 Series Accent or Wall Wash LTV50 Series Accent or Wall Wash, NF, or OPTICAL SYSTEM Architectural Accent Trees OPTICAL SYSTEM 9" DIA. (8.6 mm) 3 Optical Adjustment Lens Ring: One-piece cast bronze, natural finish. (Optional standard Stainless Steel lens ring is also available.) Eight captive M" blackened stainless steel hex-socket cap screws. Lens: Clear tempered borosilicate glass, J" thick, flush with lens ring, slightly crowned. Lens Gasket: One-piece molded silicone, U-channel wraps completely around lens flange. : Two-piece cast bronze, F" min. wall thickness upper and lower housing continuously soldered together. No top lip to trap dirt and moisture. Separate splice and ballast compartments, individual cast aluminum internal covers with one-piece molded silicone gaskets. Two L" NPT in bottom of 4 cu in. splice area. Modular reverse draft housing design (top smaller than largest bottom diameter). : High temperature, compression molded, fiberglass impregnated, F" min. wall composite. Charcoal gray. No top lip to trap dirt and moisture. Solid brass knurled inserts molded-in to receive lens ring screws. Separate splice and ballast compartments, individual cast aluminum internal covers, with silicone gaskets. Two L" NPT in bottom, 4 cu in. splice area. Modular reverse draft design (top dia. smaller than bottom), body and ballast modules epoxy bonded. Optical System: and NF - Spot or Narrow Flood spun aluminum, specular Alzak, black Duranodic arc tube glare shield on only. (G base socket option available.) - for lamps, or PAR36 and AR V lamps in LTV754 / LTV54 only. All sockets 4KV medium base. All optical systems yoke mounted, 3 rotation, ±5 vertical adjustment, locking screws, black anodized gimble ring. - onepiece hydroformed, specular Alzak, 3 rotation and screw locks, Wall Wash distribution, medium base 4KV socket for HID lamps,. (G base socket option available.) Minican socket for halogen lamps. Electrical Module: High power factor ballast, -F starting, factory mounted to gasketed compartment cover, LTV750 / LTV50 and LTV75 / LTV5 only. Wiring: Anti-siphon barriers on all wiring to and from ballast compartment. All components wire linked for ground, quick-disconnect for removal of optical system. L" (9. mm) 5 5 Listings and Ratings UL cul 598 IP68 Rated CE 5C Ambient Suitable for wet recessed Signs Facades Drive-over Durability: When installed in concrete (see page 9), fixture will withstand drive-over by vehicles weighing up to 5,500 lb. L" (33.9 mm) " (50.8 mm) 0" DIA. (54.0 mm) Vertical adjustment shown for LTV750 / LTV50, LTV75 / LTV5 and LTV754 / LTV54 only. () L" NPT 8 KIM LIGHTING

21 Ordering Example: LTV75 / / 0HAL0 / HS50 / GM50 Fixture Optics Lamp Mode Options Ordering Information Fixture Optics Lamp Mode Options (See pages 6-7) LTV750 HID Accent LTV50 HID Accent LTV75 Halogen Accent LTV5 Halogen Accent LTV75 HID Wall Wash LTV5 HID Wall Wash LTV753 Halogen Wall Wash LTV53 Halogen Wall Wash LTV754 Low Voltage Accent LTV54 Low Voltage Accent Spot NF Narrow Flood Yoke mounted and medium base socket for ED-7 HID lamp. PAR Lamp Yoke mounted medium base socket for halogen lamp. Wall Wash Hydroformed and medium base socket for ED-7 HID lamp. Wall Wash Hydroformed and socket for T-4 halogen mini-can lamp. PAR Lamp Yoke and slip-on wire tabs for PAR36 or AR V lamp. PAR Lamp Yoke mounted medium base socket for HID lamp. Pulse Start 50PMH0 50PMH08 50PMH40 50PMH77 50HPS0 50HPS08 50HPS40 50HPS77 50HPS347 70PMH0 70HPS0 70PMH08 70HPS08 70PMH40 70HPS40 70PMH77 70HPS77 70PMH347 70HPS347 Not available for Optics. 0HAL0 0W maximum, lower wattage lamps may be used. Pulse Start 50PMH0 50PMH08 50PMH40 50PMH77 70PMH0 70PMH08 70PMH40 70PMH77 70PMH347 High Pressure Sodium High Pressure Sodium 50HPS0 50HPS08 50HPS40 50HPS77 50HPS347 70HPS0 70HPS08 70HPS40 70HPS77 70HPS347 50HAL0 50W maximum, lower wattage lamps may be used. 00LV0 00LV77 V lamp with 0V or 77V input to fixture. 00W maximum, lower wattage lamps may be used. Compact Fluorescent 3PL0 3PL08 3PL40 3PL77 Compact Fluorescent 6PL0 6PL08 6PL40 6PL77 G Base Socket available for 70W Pulse Start T-6 Bi-pin lamps. HS50 Half Shield lens ring, cast bronze. RG50 Rock Guard lens ring, cast bronze. NOTE: Use of Rock Guard (RG50) will cast shadows on lighted surfaces with clear lamp. Use coated lamp. See page 6 for more information. SS50 Brushed Stainless Steel Lens Ring TR50 Trim Ring for flush mounting in concrete, brass. GM50 Grout Mask for fixture support during concrete pour, galvanized steel. TR50 Trim Ring Included. Hex Cell Louver 3,4 HL50 Installs behind main lens. (See page 7) Prismatic Lens 5 PL50 Installs behind main lens. (See page 7) Spread Lens 5 SL50 Installs behind main lens. (See page 7) 3 Not for use with LTV75 / LTV5 or LTV753 / LTV53 optical systems. 4 Not for use with PL50 or SL50 lenses. 5 Not for use with HL50 louver. Lamps by others - see pages for lamp guide. 0 HAL0 Line Volts Lamp Type: PMH = Pulse Start HPS = High Pressure Sodium HAL = Halogen PL = Compact Fluorescent LV = Low Voltage Lamp Watts KimNOW! Available Configurations: KN-LTV50/70PMH*, KN-LTV50NF/70PMH*, KN-LTV5/70PMH* Accessories: KN-GM50, KN-HS50, KN-RG50, KN-TR50 * Multi-tap ballast (0, 08, 40, or 77 volts) KIM LIGHTING 9

22 Specifications LTV750 Series Accent or Wall Wash LTV50 Series Accent or Wall Wash, NF, or OPTICAL SYSTEM Architectural Accent Trees OPTICAL SYSTEM Signs 0 KIM LIGHTING Facades LTV / LTV55-58 series fixtures are designed for applications requiring additional lamp tilt. Greater fixture setback from the lighted object is allowed, producing a flatter lighting effect. 3 9" DIA. (8.6 mm) Optical Adjustment (In 45 increments) 3E" (97.8 mm) L" (33.9 mm) 5 3M" (84. mm) 30 5 () L" NPT " (50.8 mm) Lens Ring: Cast bronze, natural finish, beveled for water runoff. Four captive J" blackened stainless steel hex-socket cap screws. Lens: Clear tempered flat glass, B" thick. Lens Gasket: One-piece molded silicone, U-channel wraps completely around lens flange. Eyeball: Cast bronze, natural finish. 3 rotation at 45 integrals. Eight captive M" blackened stainless steel screws. : Two-piece cast bronze, F" min. wall thickness upper and lower housing continuously soldered together. No top lip to trap dirt and moisture. Separate splice and ballast compartments, individual cast aluminum internal covers with one-piece molded silicone gaskets. Two L" NPT in bottom of 4 cu in. splice area. Modular reverse draft housing design (top smaller than largest bottom diameter). : High temperature, compression molded, fiberglass impregnated, F" min. wall composite. Charcoal gray. No top lip to trap dirt and moisture. Solid brass knurled inserts molded-in to receive lens ring screws. Separate splice and ballast compartments, individual cast aluminum internal covers, with silicone gaskets. Two L" NPT in bottom, 4 cu in. splice area. Modular reverse draft design (top dia. smaller than bottom), body and ballast modules epoxy bonded. Optical System: and NF - Spot or Narrow Flood spun aluminum s, specular Alzak, black Duranodic arc tube shield on only. (G base socket option available.) - for lamps, or PAR36 and AR V lamps. All optical systems yoke mounted, +0, - vertical adjustment (0 to from 0 vertical) with locking screws. - one-piece hydroformed, specular Alzak, Wall Wash distribution. All medium base sockets rated 4K. (G base socket option available.) Mini-can sockets for halogen lamps. Electrical Module: High power factor ballast, -F starting. Electrical components factory mounted to gasketed compartment cover. Wiring: Anti-siphon barriers on all wiring to and from ballast compartment. All components wire linked for ground, quick-disconnect for removal of lamp bracket.. Listings and Ratings UL cul 598 IP68 Rated CE 5C Ambient Suitable for wet recessed 0" DIA. (54.0 mm)

23 Ordering Example: LTV756 / / 0HAL0 / GM50 Fixture Optics Lamp Mode Options Ordering Information Fixture Optics Lamp Mode Options (See pages 6-7) LTV755 HID Accent LTV55 HID Accent LTV756 Halogen Accent LTV56 Halogen Accent Spot NF Narrow Flood Yoke mounted and medium base socket for ED-7 HID lamp. PAR Lamp Yoke mounted medium base socket for halogen lamp. PAR Lamp Yoke mounted medium base socket for HID lamp. High Pressure Sodium 50PMH0 50HPS0 50PMH08 50HPS08 50PMH40 50HPS40 50PMH77 50HPS77 50HPS347 70PMH0 70HPS0 70PMH08 70HPS08 70PMH40 70HPS40 70PMH77 70HPS77 70PMH347 70HPS347 Not available for Optics. 0HAL0 0W maximum, lower wattage lamps may be used. Compact Fluorescent 3PL0 3PL08 3PL40 3PL77 G Base Socket available for 70W Pulse Start T-6 Bi-pin lamps. TR50 Trim Ring for flush mounting in concrete, brass. GM50 Grout Mask for fixture support during concrete pour, galvanized steel. TR50 Trim Ring Included. LTV757 HID Wall Wash LTV57 HID Wall Wash Wall Wash Hydroformed and medium base socket for ED-7 HID lamp. 50PMH0 50PMH08 50PMH40 50PMH77 70PMH0 70PMH08 70PMH40 70PMH77 70PMH347 High Pressure Sodium 50HPS0 50HPS08 50HPS40 50HPS77 50HPS347 70HPS0 70HPS08 70HPS40 70HPS77 70HPS347 Compact Fluorescent 6PL0 6PL08 6PL40 6PL77 LTV758 Halogen Wall Wash LTV58 Halogen Wall Wash LTV759 Low Voltage Accent LTV59 Low Voltage Accent Wall Wash Hydroformed and socket for T-4 halogen mini-can lamp. PAR Lamp Yoke and slip-on wire tabs for PAR36 or AR V lamp. Lamps by others - see pages for lamp guide. 0 HAL0 Line Volts Lamp Type: PMH = Pulse Start HPS = High Pressure Sodium HAL = Halogen PL = Compact Fluorescent LV = Low Voltage Lamp Watts 50HAL0 50W maximum, lower wattage lamps may be used. 00LV0 00LV77 V lamp with 0V or 77V input to fixture. 00W maximum, lower wattage lamps may be used. Hex Cell Louver 3,4 Spread Lens 5 HL30 Installs behind main lens. (See page 7) Prismatic Lens 5 PL30 Installs behind main lens. (See page 7) SL30 Installs behind main lens. (See page 7) 3 Not for use with LTV757 / LTV57 or LTV758 / LTV58 optical systems. 4 Not for use with PL30 or SL30 lenses. 5 Not for use with HL30 louver. KIM LIGHTING

24 Specifications LTV7 Accent Lens Ring: Cast bronze with natural finish. (Optional standard Stainless Steel lens ring is also available.) Eight captive M"" blackened stainless steel hex-socket cap screws. Lens: Tempered clear soda lime, F" thick, flush with lens ring, slighty crowned,. Lens Gasket: One-piece molded silicone, U-channel wraps completely around lens flange. : High temperature, compression molded, fiberglass impregnated, F" min. wall composite. Charcoal gray. No top lip to trap dirt and moisture. Molded-in solid brass knurled inserts to receive socket base screws. Separate driver and splice compartments, individual cast aluminum internal covers, with silicone gaskets. Two L" NPT in bottom, 4 cu in. splice area. Body and driver modules epoxy bonded. Optical System: 8 LED emitters configured in a circular array, mounted on a yoke providing ±5 vertical adjustment and 3 horizontal rotation, locking screws. Available in Cool White (approx K). LED Driver: electronic drivers, rated watts and 6 watts. Available in 0V input. 0 F. stating temperature. All drivers are Underwriters Laboratories recognized. Wiring: Anti-siphon barrier on wiring to and from splice compartment. All components wire linked for ground, quick-disconnect for removal of optical system. Listings and Ratings UL cul 598 IP68 Rated CE 5C Ambient Suitable for wet recessed OPTICAL SYSTEM 9" DIA. (8.6 mm) Architectural Accent Trees 3 Optical Adjustment 5 5 () L" NPT L" (9. mm) 8L" (.3 mm) 9" Dia. (8.6 mm) Grade " (50.8 mm) 0" DIA. (54.0 mm) KIM LIGHTING

25 Ordering Example: LTV756 / / 8LED0 / GM50 Fixture Optics Lamp Mode Options Ordering Information Fixture Optics Lamp Mode Options (See pages 6-7) LTV7 Composite Housing LEDAccent Spot Yoke mounted circular array of 8 Light Emitting Diodes. NF Narrow Flood 8LED0 8LED77 HS50 Half Shield lens ring, cast bronze. RG50 Rock Guard lens ring, cast bronze. NOTE: Use of Rock Guard (RG50) will cast shadows on lighted surfaces with clear lamp. Use coated lamp. See page 6 for more information. SS50 Brushed Stainless Steel Lens Ring TR50 Trim Ring for flush mounting in concrete, brass. Colored LEDs Consult factory for color options. Hex Cell Louver 3 HL50 Installs behind main lens. (See page 7) Prismatic Lens 4 PL50 Installs behind main lens. (See page 7) Spread Lens 4 SL50 Installs behind main lens. (See page 7) 3 Not for use with PL50 or SL50 lenses. 4 Not for use with HL50 louver. 8 LED 0 Line Volts Lamp Type: LED =Light Emitting Diodes Lamp Watts KIM LIGHTING 3

26 Specifications LTV760 Series Die-Cast Brass Accent or MR OPTICAL SYSTEM Architectural Accent Signs Trees Facades 9 3" (5. mm) 7 3" (78. mm) 6" DIA. (5.4 mm) 3 Optical Adjustment " (5. mm) K" 5 7 3" (38. mm) (40.5 mm) Lens Ring: Die-cast brass, natural finish. (Optional standard Stainless Steel lens ring is also available.) Five captive J" blackened stainless steel hex-socket cap screws. Lens: Clear tempered soda lime, F" thick, flush with lens ring, slightly crowned. Lens Gasket: One-piece molded silicone, U-channel wraps completely around lens flange. Die-Cast Brass Housing: Heavy wall die-cast brass. Integral Junction Box: Die-cast brass with stainless steel flat head slotted screws and molded silicone gasket. Die-cast internal junction box cover with silicone gasket and anti-siphon plug, two K" NPT taps in bottom, cu in. volume. LTV76, LTV764, and LTV769 only. Optical System: - for PAR0 lamps in LTV76 only. All sockets medium base. All optical systems yoke mounted, 3 rotation, ±5 vertical adjustment, locking screws. MR - for MR6 lamps in LTV764 and LTV766 only. Bipin socket for halogen lamps. LED - 6 LED emitters in LTV767 configured in a circular array mounted on yoke providing ±5 vertical adjustment and 3 rotation with locking screws. Also, 3 or 9 LED emitters in LTV768 configured in a rectangular array comprised together as a module. Emitters are directly attached to the electronic drivers. For LTV769 - Spun specular Alzak. and NF Spot or Narrow Flood. The and socket are mounted to an adjustable yoke for aiming optics. Socket base: T4, G8.5 Bi-pin. LED Driver: LTV767 - Electronic driver is rated for 6 watts. Available in 0V input, 0 F. starting temperature. LTV768 - Constant current electronic driver is rated for 5 or 5 watts. Available in 0V or 77V input 0 F. starting temperature. Transformer: Integral 0 volt to volt, 50 watt electronic stepdown transformer for LTV764 only. Electrical Modules: LTV769 - Solid state electronic 0 watt metal halide ballast, 0 through 77 volt input, high power factor, ballasts are rated - F. starting. Wiring: Anti-siphon barrier on wiring to and from splice compartment. All components wire linked for ground, quick-disconnect for removal of optical system. Cable: #8- volt cable with fork connector, sealed entry into body with anti-siphon plug for LTV766 only. 4 KIM LIGHTING () K" NPT D" (4.3 mm) In-grade LTV76, LTV764, LTV767,LTV768, LTV769 6J" DIA. (58.8 mm) Surface or In-grade LTV766 Only Cable Listings and Ratings UL cul 598 IP68 Rated CE 5C Ambient Suitable for wet recessed

27 Ordering Example: LTV76 / / 50HAL0 / HS60 / TR60 Ordering Information Fixture Optics Lamp Mode Options Fixture Optics Lamp Mode Options (See pages 6-7) LTV76 Die-Cast Brass Halogen Accent PAR Lamp Yoke mounted medium base socket for PAR0 lamp. 50HAL0 HS60 Half Shield lens ring, cast bronze. RG60 Rock Guard lens ring, cast bronze. LTV764 Die-Cast Brass Low Voltage Accent Integral Transformer LTV766 Die-Cast Brass Low Voltage Accent Remote Transformer (See page 6) LTV767 Die-Cast Brass LED Accent MR MR6 Halogen Yoke mounted bipin socket for MR6 lamp. MR MR6 Halogen Yoke mounted bipin socket for MR6 lamp LED 6 emitters Yoke mounted socket for Light Emitting Diodes 50LV0 50W maximum, lower wattage lamps may be used. V lamp with 0V input to fixture. 75LV0 75W maximum, lower wattage lamps may be used. 6LED0 6W maximum, SS60 Brushed Stainless Steel Lens Ring TR60 Trim Ring for flush mounting in concrete, brass. Colored LEDs Consult factory for color options. Hex Cell Louver L Clips to MR6 lamp. L0 Clips to PAR0 lamp. HL73 Installs behind main lens. (See page 7) LTV768 Die-Cast Brass LED Flood LTV769 Die-Cast Brass Pulse Start Metal Halide Accent LED 3-9 emitters Rectangular array module for Light Emitting Diodes Spot NF Narrow Flood Yoke mounted and socket for T4, G8.5 Bi-pin PMH lamp 5LED0 5LED77 5LED0 5LED77 Pulse Start 0PMH0 0PMH08 0PMH40 0PMH77 Prismatic Lens 3 PL73 Installs behind main lens. (See page 7) Spread Lens 3 SL73 Installs behind main lens. (See page 7) Not for use with PL73 or SL73 lenses. 3 Not for use with HL73 Louver. Lamps by others - see pages for lamp guide. 50 HAL 0 Line Volts Lamp Type: HAL = Halogen LV = Low Voltage LED = LED emitters PMH = Pulse Start Lamp Watts KIM LIGHTING 5

28 Options Option Catalog No. and Details (See individual fixture pages for application.) HS0 For and LTV70 / LTV0 Series fixtures only. HS50 For LTV750 / LTV50 Series and LTV7 fixtures only. HS60 For LTV760 Series fixtures only. D" DIA. (95.3 mm) 64 9" DIA. (8.6 mm) 63 6" DIA. (5.4 mm) Half Shield lens ring for directional glare control toward the viewer. One-piece cast bronze, replaces standard lens ring. Includes glass lens gasket and mounting screws. 4D" (7.5 mm) 4 3L" (95.3 mm) 5 3" (76. mm) RG0 For and LTV70 / LTV0 Series fixtures only. RG50 For LTV750 / LTV50 Series and LTV7 fixtures only. RG60 For LTV760 Series fixtures only. Rock Guard lens ring for lens protection in vandal prone areas. One-piece cast bronze, replaces standard lens ring. Includes glass lens gasket and mounting screws. L" (44.5 mm) D" DIA. (95.3 mm) L" (44.5 mm) 9" DIA. (8.6 mm) CAUTION: On LTV7 / LTV and LTV75 / LTV5 ( Optics), Rock Guard will cast severe shadows on the lighted surface with clear lamps. If Rock Guard is required, use coated lamps and estimate a reduction in longitudinal light throw and intensity. Rock Guard not recommended for LTV73 / LTV3 and LTV753 / LTV53 halogen wall wash fixtures. SS0 For and LTV70 / LTV0 Series fixtures only. SS50 For LTV750-LTV754 / LTV50-LTV54 and LTV7 fixtures only. F" (30. mm) SS60 6" DIA. (5.4 mm) For LTV760 Series fixtures only. Stainless Steel lens ring. One-piece standard brushed stainless steel, replaces standard lens ring. Includes glass lens gasket and mounting screws. TR0 x" D" DIA. (95.3 mm) For, LTV70 / LTV0, LTV730 / LTV30 and LTV740 / LTV40 Series fixtures only. TR50 9" DIA. x" (8.6 mm) X" For LTV750 / LTV50 Series and LTV7 fixtures only. TR60 6" DIA. (5.4 mm) For LTV760 Series fixtures only. Trim Ring for flush mounting of fixture in concrete pad or paving. Brass ring clamps to housing with stainless steel screw. 6 KIM LIGHTING " (50.8 mm) Trim Ring GRADE " DIA. (304.8 mm) E" (. mm) H" (7.5 mm) Hex Nut and Bolt TR0 and TR50 Installation Detail Debris Shield " 9J" DIA. (50.8 mm) (34.9 mm) " (50.8 mm) Trim Ring GRADE D" (5.9 mm) 6J" DIA. (58.8 mm) K" (.7 mm) Hex Nut and Bolt TR60 Installation Detail Debris Shield Housing

29 Option Catalog No. and Details (See individual fixture pages for application.) Installation Details Trim Ring Grout Debris Shield Grout Mask Concrete GM0 GM30 For and LTV740 / LTV40 Series fixtures only. For LTV70 / LTV0 and LTV730 / LTV30 Series fixtures only. GM50 For LTV750 / LTV50 Series fixtures only. 6J" DIA. (4.8 mm) 3J" DIA. (336.6 mm) Grout Mask for fixture support during concrete pour. Gal vanized steel ring and rebar supports fixture when tied into paving rebar. " grout space provided for finishing up to fixture. See page 9. Fixture Housing Conduit and Rebar (by others) Tie Wire Anchor (by others) GM0 (0L") (73. mm) GM30 (6K") (65. mm) TR0 included (50.8 7F" (87. mm) " (50.8 mm) TR50 included Lens Accessory Guide - Installs behind main fixture lens Hex Cell Louvers - Internal Constructed of hex cell aluminum louvers providing 45 cutoff, mounted in a circular frame, finished in baked high-heat flat black. Can be used in combination with colored lenses. L and L0 clip onto rim of lamp with spring-steel clips. HL Series louvers cannot be used in combination with Prismatic or Spread lenses. Installation Details Lens Gasket Housing Lens / Accessory Guide Lens Lens Frame HL0 HL30 HL50 HL73 L L0 Prismatic Lens Spread Lens PL Softens lamp distribution. Best with flood lamps. Raw flood lamp distribution Creates an oval beam pattern. Best with spot lamps. Raw spot lamp distribution Inserts behind lens into lens gasket. Cannot be used in combination with HL Series louvers. SL HL Hex Cell Louver / PL Prismatic Lens / SL Spread Lens install in lens gasket behind fixture lens. HL, PL, and SL accessories can be used with colored filters but not with each other. KIM LIGHTING 7

30 LTV766 Remote Transformers 0 Volt to Volt ORDERING INFORMATION ABOVE GRADE TRANSFORMERS Cat. No. Description KLV watt () circuit KLV watt () circuit KLV watt () circuits KLV watt (3) circuits K" knockouts (3 places) 5C" (36.5 mm) 5" (38.0 mm) 5K" (39.7 mm) KLV watt KLV watt K" knockouts (3 places) 6K" (65. mm) K" knockouts (3 places) 6K" (65. mm) 5" (38.0 mm) KLV watt 7" (43.8 mm) 5K" (39.7 mm) 5K" (39.7 mm) 3" (76. mm) 7" (77.8 mm) 3" (76. mm) 7" (77.8 mm) 3" (76. mm) 8" (03. mm) See the Kim Volt / 0 Volt Landscape catalog for the full range of low voltage accessories. ECIFICATIONS ABOVE GRADE TRANSFORMERS Enclosure: Formed 6 ga. stainless steel enclosure with integral hinge. Cover is secured with two stainless steel screws. A through hole is provided in the bottom edge for a padlock (by others). K" knockouts on each side of the enclosure are provided for hardwiring or accessory photocell mounting. Transformer: Core and coil type fully epoxy encapsulated. Output is multi-tap V / 3V / 4V / 5V. The 00 and 300-watt units have single circuit output, the 600-watt unit has two circuits for output, and the 900-watt unit has three circuits for output. Variable taps provide flexibility in system design with the -volt tap for fixtures near the transformer location and higher voltages for more remote fixtures. Terminal Block: 80-amp euro-style terminal block. Circuit Breaker: 5 amp magnetic circuit breaker () per circuit. Cord: Six foot, heavy duty outdoor power cord is provided and installed (#8- SJTW). Certification: UL Listed to U.S. and Canadian safety standards for wet locations. KLV watt volt volt ORDERING INFORMATION 0 volt 8J" (09.6 mm) IN-GRADE TRANSFORMERS Cat. No. Description KLV55 50 watt In-grade Transformer KLV watt In-grade Transformer Specify finish: BL - Black, DB - Dark Bronze, GR - Verde Green Cat. No. - Example: KLV55DB J" (3. mm) Elevated for drainage in soil or gravel 4E" (3.7 mm) 3 /6" (.3 mm) IN-GRADE TRANSFORMERS Enclosure: Cast aluminum hous ing and cover, full silicone gasket, cover fas tens with ten stainless steel allen head screws. Internal heat barrier between transformer and com ponents. Anti-siphon chamber for -volt connection. Trans former: Core and coil, wired to terminal block. Terminal Block: Black phenolic with brass connectors. Circuit Breaker: Mounted on secondary side of transformer to prevent overloading. (KLV55) -30A, (KLV530) -30A, mounted to terminal block plate. Conduit Taps: Two L" NPT in bottom. Splice compartment volume 9 cubic inches, approved for through wiring. Finish: Super TGIC thermoset polyester powder coat paint applied over a titanated zirconium conversion coating. Standard colors are Black (BL), Dark Bronze (DB), and Verde Green (GR). Amps: 50W.5, 500W 5.. In-grade Transformers must be conduit fed for the 0 Volt input with Ground Fault Circuit Interrupter (G.F.C.I.) Protection. They can be set directly into soil or gravel. It is recommended that transformers be slightly elevated to encourage water drainage away from the housing. NOTE: The total wattage of all fixtures connected to one transformer must not exceed the total wattage capacity of that transformer. 8 KIM LIGHTING

31 Installation Guide Common Installation Problems The single most common error made when installing in-grade luminaires is mounting them too low. When this happens the fixture becomes a sump, collecting dirt and debris which covers the lens and blocks the light. The second most common error is planting too close to the fixture. When this happens, foliage grows over the luminaire because there is no obvious surface for landscape edge trimming. Based on four decades of experience with in-grade luminaires, Kim Lighting recommends the installation guidelines below. Isolate and Elevate. The fundamentals of a clean, maintainable installation. Create a Buffer Zone When fixtures are located in areas planted in ground cover or shrubbery, construct a buffer zone to prevent lens overgrowth and to create an edge for trimming. Elevate the fixtures for drainage and backfill with decorative rock. As the ground cover grows, the fixtures will look flush even though they are " to 4" above grade. Advantages Prevents lens overgrowth. Provides a defined edge for trimming. Provides drainage away from the lens to maintain light output. Visually looks like a flush installation. Buffer Zone Redwood or other material for edging. Rock fill " to 4" above grade. Install in Concrete Another option for installations in ground cover, shrubbery or lawn areas is to encase the fixture in concrete. This creates the buffer zone as described above, with the additional advantage of greater fixture stability. Elevate the fixture " to 4" above grade, and slope the concrete away from the lens ring for drainage. Advantages Cleaner, more stable installation, less susceptible to traffic and maintenance activity. Prevents lens overgrowth. Provides a defined edge for trimming. Provides drainage away from the lens to maintain light output. Visually looks like a flush installation. Concrete Installation Concrete must have reinforcing rods to prevent cracking from fixture heat expansion. Rock fill " to 4" above grade. NOTE: Always use adequate rebar surrounding the fixture to prevent cracking of the concrete due to heat expansion. In Paved Areas When in-grade luminaires are installed in paving, it is usually required that the lens frame be flush with finished grade. To make this installation easier, Kim offers an optional Grout Mask (page 7) to support the fixture at the proper height during the concrete pour. The Grout Mask is normally tied into the paving rebar for support. Advantages Supports fixture at proper height during concrete pour. Provides " grout space for finishing. Easily adapts to any paving material; concrete, brick, stone, etc. Provides maximum Drive-over durability. Paved Area Installation Optional grout mask supports fixture during concrete pour. Tie grout mask to rebar for support. " grout space for finishing. Encase entire fixture in Concrete NOTE: See Safety and Maintenance Notes on page 47. KIM LIGHTING 9

32 Installation Details - LTV740 / LTV40 After pulling wire into splice compartment, seal conduit by injecting RTV silicone sealer into open end to completely block entry of water Clean all gasket, interior housing, and cover plate surfaces thoroughly. Install compartment gaskets and covers and tighten all fasteners to a minimum of 0 inch/pounds (.67 ft. lbs.). Install lamp into fixture and test for operation. Clean all gasket, housing, and lens ring surfaces and assemble, leaving fasteners loose. See page 3 for clearing of moist air from the interior of the fixture prior to completely sealing. After exhausting moist air from the fixture, tighten lens ring bolts to a minimum of 30 inch/pounds (K ft. lbs.). Tighten bolts in a staggered pattern indicated in the illustration. Lens ring bolt tightening sequence Splice Compartment Cover Anti-siphon Barrier 7 5 Seal conduit at entry with RTV to prevent moisture from entering through conduit system Conduit (by others) Debris Shield included with fixture Ballast Compartment Cover Anti-siphon Barrier Ballast Compartment LTV750 / LTV50 After pulling wire into splice compartment, seal conduit by injecting RTV silicone sealer into open end to completely block entry of water. Clean all gasket, interior housing, and cover plate surfaces. Install compartment gasket and cover and tighten fasteners to a minimum of 0 inch/pounds (.67 ft. lbs.). Repeat operation for ballast compartment cover. Install lamp into fixture and test for operation. Clean all gasket, housing, and lens ring surfaces and assemble, leaving fasteners loose. See page 3 for additional clearing of moist air from the interior of the fixture prior to completely sealing. After exhausting moist air from the fixture, tighten all lens ring bolts to a minimum of 30 inch/pounds (K ft. lbs.). Tighten bolts in a staggered pattern indicated in the illustration. Lens ring bolt tightening sequence Anti-siphon Barrier 5 Seal conduit at entry with RTV to prevent moisture from entering through conduit system Debris Shield included with fixture Conduit (by others) Ballast Compartment Cover Ballast Compartment Splice Compartment L" plug LTV760 After pulling wire into splice compartment, seal conduit by injecting RTV silicone sealer into open end to completely block entry of water. After completion of splice compartment wiring, clean all gasket, interior housing, and cover plate surfaces. Install compartment gasket and cover and tighten fasteners to a minimum of 5 inch/pounds (J ft. lbs.). Install lamp into fixture and test for operation. Clean all gasket, housing, and lens ring surfaces and assemble, leaving fasteners loose. See page 3 for additional clearing of moist air from the interior of the fixture prior to completely sealing. After exhausting moist air from the fixture, tighten all lens ring bolts to a minimum of 0 inch/pounds (.67 ft. lbs.). Tighten bolts in a staggered pattern indicated in the illustration. 30 KIM LIGHTING Lens ring bolt tightening sequence Seal conduit at entry with RTV to prevent moisture from entering through conduit system Conduit (by others) Anti-siphon Barrier Splice Compartment L" plug

33 Controlling Moisture within In-Grade Luminaires Sources of Moisture Intrusion Moist air trapped in fixture during installation Unsealed conduit and conduit connectors Poor gasket sealing from loose cover or trapped debris Flooding caused by poor grade conditions Poor gasket seal of interior covers from loose fasteners or trapped debris Water Intrusion In order to assure that in-grade fixtures are protected from failure due to intrusion of water, observe the following essential guidelines:. Seal all conduits entering the wiring compartment. This includes both the conduit threads AND the conduit itself. Water can enter the conduit system through joints or junction boxes, and will be piped into the fixture housing if not properly sealed. Injecting RTV sealant into the end of each conduit entering the wiring compartment is essential to a water tight installation.. Use waterproof wire nuts. This provides protection against circuit failure, should water enter the junction box for any reason. 3. Make sure all gasket surfaces are completely clean before installing covers and lens rings. Any foreign objects trapped in the gasket areas will create potential points of entry for ground water. 4. Tighten all fasteners evenly and completely. All fasteners for the wiring compartments and lens rings must be properly installed and tightened evenly. It is recommended that lens ring fasteners be tightened in a cross pattern in two steps (snug and tight), to insure even pressure is applied to the entire gasket surface. 5. Never install an in-grade luminaire below the surrounding ground level. See page 9 for additional information on elevating and isolating the fixture in various surfaces. Visible Condensation on Lenses In-grade luminaires are tightly sealed bodies, with a captured atmosphere within. Condensation is caused by moisture that occurs in the air naturally (humidity) that is not completely eliminated from the interior of the fixture when it is sealed. During operation, when the luminaire is shut off, the lens cools at a faster rate than other surfaces within the fixture body. This will cause water vapor within the housing to collect on the inside of the lens. The higher the relative humidity during installation, the greater the condensation will be. The following installation guidelines will reduce the occurrence of condensation:. Never install or maintain fixtures in the rain, or on days with very high relative humidity (over 80%).. After insuring that all water and visible moisture has been dried out of the fixture, and before sealing the fixture; a.) Install the lens ring and hand tighten all fasteners, b.) Start the fixture and allow it to reach operating temperature (30 minutes or longer), c.) With the fixture still operating, loosen all lens ring fasteners and lift the lens ring slightly (no more than A"), leaving it propped open and breathing for roughly 0 minutes with the lamp operating. This will exhale the moist air trapped inside the fixture housing. d.) With the fixture still operating (illuminated) and hot, place the lens in its closed position and completely tighten all fasteners. This process will evaporate a great deal of the atmospheric moisture from the interior of the fixture, and will reduce visible condensation to a minimum. In order to maintain this, this procedure must be repeated any time the luminaire is opened for maintenance. It is highly recommended that the installer wear gloves to protect from burns caused by hot lens surfaces. Do not leave fixtures un-supervised during dry-out period. 3. Should water be found inside of the fixture that has entered through the conduit system, it is essential that the conduit system be cleaned, dried out and re-sealed before the fixture is re-sealed. 4. Every effort must be made to ensure the fixture interiors remain completely dry during installation. The debris shields provided with the fixtures are not water tight. If flooding is anticipated during the installation phase, extra effort must be made to isolate the fixtures from water intrusion, or they must be sealed off with plastic sheet and tape to prevent water entry. 5. Should the appearance of condensation increase in density or size of droplets, it is likely that water is entering the fixture. Inspect all gaskets, conduit entries, and interior covers. Once the leak has been discovered and repaired, repeat the sealing process described (# above). KIM LIGHTING 3

34 Application Guide Spot Visual Guideline: The Lightvault product line offers a wide range of optical systems and lamps, capable of lighting diverse architectural and landscape objects. To all but the most experienced lighting professional, it is difficult to visualize the application capabilities by simply reading the photometric charts on pages This two page spread has been created as a visual reference and general guideline for selecting the proper Lightvault fixture. In every case, verification that selected fixtures and layout meet the lighting criteria, must be made from published photometric data. See page 34 for a guide to understanding and using the data. Recommended Fixtures: The listed Fixtures, Optics, and Lamp Modes should be considered general guidelines. Selection of the proper fixture, number of fixtures and spacing should be based on photometric data. 80' 70' Fixture: LTV730 / LTV30 LTV750 / LTV50 LTV760 Optics: NF or or MR Lamp: 50MH 50HPS 50MH 50HPS 70MH 50HAL 75MH 50 HPS 75MH 75MH 00MH 75HAL 50MH 50HAL 75MH 70HPS 00HPS 50HPS Photo Reference: In addition to the diagrams above and the photometric charts on pages 35-46, it helps to see the actual lighting effect and beam width. In order to make meaningful comparisons, the same wall was used for all fixtures. The Spot () and Narrow Flood (NF) Accent lights are shown grazing a smooth wall surface to demonstrate the effectiveness of these fixtures for grazing light up columns and textured walls, which can be very dramatic. Trees, flags and overhangs reflect light back to the viewer just like the moldings in these photographs. The highlight on the molding indicates the light intensity that might occur on leaves and flags as their surface angles change in the wind. It also indicates the intensity of light on overhangs and ceilings, which reflect light more directly toward the viewer. All photo graphs are of individual fixtures, and therefore are not indicative of multiple fixture layouts with overlapping beams. Molding 4' 4" 5' 00MH 6 00MH 3 KIM LIGHTING

35 Narrow Flood Wall Wash 80' 70' Lightvault Fixture: LTV70 / LTV0 LTV730 / LTV30 LTV750 / LTV50 LTV730 / LTV30 LTV750 / LTV50 LTV750 / LTV50 LTV760 LTV750 / LTV50 LTV760 LTV760 Optics: NF NF or NF or MR or MR or MR Lamp: 70MH 50HAL 70MH 50HAL 50MH 50HAL 70MH 50HAL 70MH 50HAL 00MH 75HAL 00MH 75HAL 70MH 75HAL 00MH 70HPS 00MH 70HPS 50MH 50HAL 50MH 50HAL 00MH 50HAL 50MH 00HPS 50MH 00HPS 75MH 70 HPS 75MH 70 HPS 50MH 70 HPS 75MH 50HPS 75MH 50HPS 00 HPS 00 HPS 75MH 00 HPS 50 HPS 50 HPS 50 HPS LTV70 / LTV0 Wall Wash 00MH 36" NF 00MH 35 00MH LTV730 / LTV30 Wall Wash 00MH 36" KIM LIGHTING 33

36 Photometric Guide Spot and NF Narrow Flood Candlepower: The left half of the photometric chart shows the luminous intensity at various angles, measured in a vertical plane through the light center. The curve is symmetrical about the center line, and is commonly known as a candlepower distribution curve. Fixture: Optics: Lamp Mode: Candlepower 4,000 35,000 8,000,000 4,000 7, NF 75MH Beam Width and Center Footcandles 34 80' 75W in Narrow Flood Description of lamp and optical system Center Footcandles: On the beam centerline, footcandle values are shown at various distances from the fixture. Since the beam edge (dashed line) is of the centerline value, the footcandles at the edge would be of the number shown in the center. Beam Width: This included angle, sym metrical about the centerline, is constructed by drawing a dashed line through the candlepower curve at of the useful beam width that will produce acceptable uniformity of illumination. Application of Data: The final objective is to select the proper LTV luminaire, optical system and lamp that will produce the desired illumination. This can be derived from the beam width, footcandle and distance values shown on the right side of the photometric charts. It may be necessary to construct a scaled elevation of the object to be illuminated (example at right) to determine the ideal beam width. Remember, an object can be lighted from multiple locations to achieve the desired coverage and illumination level. Basic I.E.S. footcandle recommendations: Object Dark Surroundings Bright Surroundings Trees 5fc 0-0fc Flags 0fc 50fc Example using data from chart above: '.Dia. 3fc on foliage Basic Formula: Using candlepower data from the left side of the photometric chart. cp =fc d cp candlepower at 0 d distance from fixture to object in feet fc footcandles Example: Based on example photometric chart and application diagram at left. 36,800 cp =3fc 40 Wall Wash Footcandles: Photometric charts for (Wall Wash) optics show lines of equal footcandle values on a vertical surface, with the fixture located from the surface. Distances up and along the vertical surface are shown. Since the overall light pattern is symmetrical in halves, only one half is shown for easier readability. Fixture: Optics: Lamp Mode: Footcandle Diagram Typical Half, fixture from wall..5 LTV7 / LTV 70MH 5 70W Description of lamp and optical system. 0 reference fixture centerline The complete light pattern is symmetrical in two halves about the 0 reference line. The fixture is located from the surface to the fixture centerline. 34 KIM LIGHTING

37 Photometrics LTV70 Series LTV0 Series 90,000 75, ,000 87, ,000 75, ,000 87, ,000 45,000 30,000 5, PMH 8 90' or T-6 70W Pulse Start in Spot 70,000 5,500 35,000 7, W HPS in Spot 70HPS 90' 60,000 45,000 30,000 5, PMH 90' 00W Pulse Start in Spot 70,000 5,500 35,000 7, W HPS in Spot 00HPS 90' 0,000 00, ,000 0, ,000 00, ,000 60,000 40,000 0, PMH 90' or T-6 50W Pulse Start in Spot 88,000 66,000 44,000, HPS 5 90' 50W HPS in Spot 80,000 60,000 40,000 0, MH 3 90' 75W in Spot,000 7, , , ' 30,000 5, ' 30,000 5, ' 4,000 0,500 7,000 3, NF 70PMH 5' 45' 5' or T-6 70W Pulse Start in Narrow Flood ,000 0,500 7,000 3, NF 70HPS 33 70W HPS in Narrow Flood 0,000 5,000 0,000 5, NF 00PMH 00W Pulse Start in Narrow Flood 0,000 5,000 0,000 5, NF 00HPS 33 00W HPS in Narrow Flood 36,000 30, ' 36,000 30, ' 4,000 35, ' 4,000 8,000,000 6, NF 50PMH 3 or T-6 50W Pulse Start in Narrow Flood 4,000 8,000,000 6, W HPS NF in Narrow Flood 50HPS ,000,000 4,000 7, NF 75MH 34 75W in Narrow Flood KIM LIGHTING 35

38 Photometrics LTV70 Series LTV0 Series 30,000 5, ' 8,000 5, ,500 3, ' 0,000 5,000 0,000 5, PMH 5 70W Pulse Start 5 Spot lamp,000 9,000 6,000 3, PMH 45' 5' 5' 70W Pulse Start Flood lamp 3,000,50, PMH 65 8' 8' 70W Pulse Start 65 Wide Flood lamp 4,000 35, ',000 7, ,00 6, ' 8,000,000 4,000 7, PMH 5 5' 5' 00W Pulse Start 5 Spot lamp 4,000 0,500 7,000 3, PMH 5' 45' 5' 00W Pulse Start Flood lamp 4,800 3,600,400, PMH 65 8' 8' 00W Pulse Start 65 Wide Flood lamp 36,000 30, ',000 7, ,800 6, ' 4,000 8,000,000 6, PMH 5' 5' 50W Pulse Start Spot lamp 4,000 0,500 7,000 3, PMH 35 5' 45' 5' 50W Pulse Start 35 Narrow Flood lamp 5,00 3,900,600, PMH 65 8' 8' 50W Pulse Start 65 Very Wide Flood lamp 4,000 35, ' 9,000 7, ,000,000 4,000 7, LTV7 / LTV 50HAL 5' 5' 50W Halogen Spot lamp 6,000 4,500 3,000, LTV7 / LTV 50HAL 50W Halogen Flood lamp 36 KIM LIGHTING

39 Photometrics LTV70 Series LTV0 Series LTV7 / LTV 70PMH or T-6 70W Pulse Start LTV7 / LTV 70HPS 70W HPS LTV7 / LTV 00PMH 00W Pulse Start LTV7 / LTV 00HPS 00W HPS LTV7 / LTV 50PMH or T-6 50W Pulse Start LTV7 / LTV 50HPS 50W HPS LTV7 / LTV 75MH 75W LTV73 / LTV3 50HAL T4 Mini-can 50W Halogen KIM LIGHTING 37

40 Photometrics LTV730 Series LTV30 Series 7,000 60, ,000 60, ,000 60, ,000 60, ,000 4,000 36,000, LTV730 / LTV30 70PMH 8 90' or T-6 70W Pulse Start in Spot 48,000 4,000,000 36, LTV730 / LTV30 70HPS 70W HPS in Spot 90' 48,000 4,000,000 36, LTV730 / LTV30 00PMH 90' 00W Pulse Start in Spot 48,000 4,000,000 36, LTV730 / LTV30 00HPS 3 00W HPS in Spot 90' 90,000 75, ,000 75, ,000 75, ,000 7, ,000 30,000 45,000 5, LTV730 / LTV30 50PMH 90' or T-6 50W Pulse Start in Spot 60,000 30,000 5,000 45, LTV730 / LTV30 50HPS 5 50W HPS in Spot 90' 60,000 30,000 5,000 45, LTV730 / LTV30 75MH 90' 75W in Spot 4,000 0,500 7,000 3, LTV730 / LTV30 NF 70PMH 45' 5' 5' or T-6 70W Pulse Start in Narrow Flood,000 7, ,000 5, ,000 5, ,000 30, ' 4,000 0,500 7,000 3, LTV730 / LTV30 NF 70HPS 33 5' 45' 5' 70W HPS in Narrow Flood 0,000 5,000 0,000 5, LTV730 / LTV30 NF 00PMH 45' 5' 5' 00W Pulse Start in Narrow Flood 0,000 5,000 0,000 5, LTV730 / LTV30 NF 00HPS 33 5' 00W HPS in Narrow Flood 45' 5' 8,000 4,000,000 6, LTV730 / LTV30 NF 50PMH 3 or T-6 50W Pulse Start in Narrow Flood 36,000 30, ' 36,000 30, ' 30,000 5, ' 8,000 5, ,000 4,000,000 6, LTV730 / LTV30 50W HPS NF in Narrow Flood 50HPS ,000 4,000,000 6, LTV730 / LTV30 NF 75MH 34 75W in Narrow Flood 0,000 0,000 5,000 5, LTV730 / LTV30 70PMH 5 70W Pulse Start 5 Spot lamp,000 9,000 6,000 3, LTV730 / LTV30 70PMH 5' 45' 5' 70W Pulse Start Flood lamp 38 KIM LIGHTING

41 Photometrics LTV730 Series LTV30 Series 4,500 3, ' 4,000 35, ',000 7, ,00 6, ' 3,000,50, LTV730 / LTV30 70PMH 65 8' 8' 70W Pulse Start 65 Wide Flood lamp 4,000 8,000 7,000, LTV730 / LTV30 00PMH 5 5' 5' 00W Pulse Start 5 Spot lamp 0,500 4,000 7,000 3, LTV730 / LTV30 00PMH 5' 45' 5' 00W Pulse Start Flood lamp 3,600,400 4,800, LTV730 / LTV30 00PMH 65 8' 8' 00W Pulse Start 65 Wide Flood lamp 36,000 30, ',000 7, ,500 7, ' 4,000 8,000,000 6, LTV730 / LTV30 50PMH 5' 5' 50W Pulse Start Spot lamp 4,000 0,500 7,000 3, LTV730 / LTV30 50PMH 35 5' 45' 5' 50W Pulse Start 35 Narrow Flood lamp 6,000 4,500 3,000, LTV730 / LTV30 50PMH 65 8' 8' 50W Pulse Start 65 Very Wide Flood lamp 4,000 35, ' 9,000 7, ,000 4,000 7,000, ' LTV73 / LTV3 50W Halogen Spot lamp 50HAL 5' 4,500 6,000 3,000, LTV73 / LTV3 50W Halogen Flood lamp 50HAL LTV73 / LTV3 70PMH or T-6 70W Pulse Start LTV73 / LTV3 00PMH 00W Pulse Start LTV73 / LTV3 50PMH or T-6 50W Pulse Start LTV73 / LTV3 75MH 75W KIM LIGHTING 39

42 Photometrics LTV730 Series LTV30 Series LTV73 / LTV3 70HPS 70W HPS LTV73 / LTV3 00HPS 00W HPS LTV73 / LTV3 50HPS 50W HPS LTV733 / LTV33 50HAL T4 Mini-can 50W Halogen 40 KIM LIGHTING

43 Photometrics NOTE: Photometric performance shown typical for 3 marker. marker is identical in aimed direction with full cutoff in opposite direction. LTV740 Series LTV40 Series Candlepower Beam width and vertical footcandles at grade Candlepower Beam width and vertical footcandles at grade 500 8' 500 8' ' 9 ' ' ' ' 4' 8' 4' ' 4' 8' 4' LTV740 / LTV40 70PMH or T-6 70W Pulse Start in Spot LTV740 / LTV40 70HPS 70W HPS in Spot Candlepower Beam width and vertical footcandles at grade Candlepower Beam width and vertical footcandles at grade 500 8' 500 8' ' ' ' ' ' 4' 8' 4' ' 4' 8' 4' LTV740 / LTV40 00PMH 00W Pulse Start in Spot LTV740 / LTV40 00HPS 00W HPS in Spot Candlepower Beam width and vertical footcandles at grade 8' ' ' ' 4' 8' 4' LTV74 / LTV4 0HAL 0W Halogen Spot lamp KIM LIGHTING 4

44 Photometrics LTV750 Series LTV50 Series 45,000 37, ',000 0, ,000 60, ,000 7, ,000,500 5,000 7, LTV750 / LTV50 50PMH 8 50W Pulse Start in Spot 8,000 6,000 4,000, LTV750 / LTV50 NF 50PMH 50W Pulse Start in Narrow Flood 48,000 36,000 4,000, LTV750 / LTV50 70PMH 8 90' or T-6 70W Pulse Start in Spot 4,000 0,500 7,000 3, LTV750 / LTV50 NF 70PMH 45' 5' 5' or T-6 70W Pulse Start in Narrow Flood 45,000 37, ',000 0, ,000 60, ,000 7, ,000,500 5,000 7, LTV750 / LTV50 50HPS 50W HPS in Spot 8,000 6,000 4,000, LTV750 / LTV50 NF 50HPS 3 50W HPS in Narrow Flood 48,000 36,000 4,000, LTV750 / LTV50 70W HPS in Spot 70HPS 90' 4,000 0,500 7,000 3, LTV750 / LTV50 NF 70HPS 3 5' 45' 5' 70W HPS in Narrow Flood 30,000 5, ' 8,000 5, ,500 3, ' 4,000 35, ' 0,000 5,000 0,000 5, LTV750 / LTV50 70PMH 5 70W Pulse Start 5 Spot lamp,000 9,000 6,000 3, LTV750 / LTV50 70PMH 5' 45' 5' 70W Pulse Start Flood lamp 3,000,50, LTV750 / LTV50 70PMH 65 8' 8' 70W Pulse Start 65 Wide Flood lamp 8,000 4,000 7,000, ' LTV75 / LTV5 0W Halogen Spot lamp 0HAL 59 5' 9,000 7, ,500 6,000 3,000, LTV75 / LTV5 0W Halogen Flood lamp 0HAL. LTV75 / LTV5 50PMH.5 50W Pulse Start.5 LTV75 / LTV5 70PMH or T-6 70W Pulse Start.. LTV75 / LTV5 50HPS.5 50W HPS 4 KIM LIGHTING

45 Photometrics LTV750 Series LTV50 Series 4,000 35, ',500, LTV75 / LTV5 70HPS.5 70W HPS.. LTV753 / LTV53 50HAL.5 T4 Mini-can 50W Halogen 8,000 4,000 4,000 7, LTV754 / LTV54 PAR36 50W Halogen 5 Very Narrow 50LV Spot lamp, ' 8' LTV754 / LTV54 PAR36 50W Halogen Wide Flood 50LV lamp 8' 4' 48,000 40, ' 9,000 7, ,000, ' 3,000 4,000 6,000 8, ' LTV754 / LTV54 AR 00W Halogen 8 Spot lamp 00LV 8 7 5' 6,000 4,500 3,000, LTV754 / LTV54 AR 00W Halogen 5 Flood lamp 00LV,000,500, ' LTV754 / LTV54 AR 00W Halogen 45 Wide Flood 00LV lamp 8' 48,000 40, ,400, ,000 45, ,800 4, ,000 6,000 8,000 4, LTV755 / LTV55 50PMH 8 90' 50W Pulse Start in Spot 9,600 7,00 4,800, LTV755 / LTV55 NF 50PMH 45' 5' 5' 50W Pulse Start in Narrow Flood 36,000 8,000 9,000 7, LTV755 / LTV55 50HPS 8 90' 50W in Spot,00 8,400 5,600, LTV755 / LTV55 NF 50HPS 5' 45' 5' 50W in Narrow Flood 7,000 60, ,000 7, ,000 60, ,000 7, ,000 4,000 36,000, LTV755 / LTV55 70PMH 8 90' or T-6 70W Pulse Start in Spot 4,000 0,500 7,000 3, LTV755 / LTV55 NF 70PMH 45' 5' 5' or T-6 70W Pulse Start in Narrow Flood 48,000 4,000,000 36, LTV755 / LTV55 70HPS 70W HPS in Spot 90' 4,000 0,500 7,000 3, LTV755 / LTV55 NF 70HPS 33 5' 45' 5' 70W HPS in Narrow Flood KIM LIGHTING 43

46 Photometrics LTV750 Series LTV50 Series 30,000 5, ' 8,000 5, ,500 3, ' 0,000 0,000 5,000 5, LTV755 / LTV55 70PMH 5 70W Pulse Start 5 Spot lamp,000 9,000 6,000 3, LTV755 / LTV55 70PMH 5' 45' 5' 70W Pulse Start Flood lamp 3,000,50, LTV755 / LTV55 70PMH 65 8' 8' 70W Pulse Start 65 Wide Flood lamp 7,000,500 8,000 9,000 4,500 3, ' 5' LTV756 / LTV56 0W Halogen Spot lamp 0HAL 5' 5,50 4,600,760 3,680, LTV756 / LTV56 0W Halogen Flood lamp 0HAL.07.3 LTV757 / LTV57 50PMH W Pulse Start LTV757 / LTV57 50HPS W HPS.. LTV757 / LTV57 70PMH or T-6 70W Pulse Start..5 LTV757 / LTV57 70HPS W HPS LTV758 / LTV58 50HAL T4 Mini-can 50W Halogen 48,000 40,000 3,000 6,000 4,000 8, ' 5' LTV759 / LTV59 AR 00W Halogen 8 Spot lamp 00LV 5' 9,000 7, ,000, ' 4,000 35, ',500, ,000 4,500 3,000, LTV759 / LTV59 AR 00W Halogen 5 Flood lamp 00LV,000,500, ' LTV759 / LTV59 AR 00W Halogen 45 Wide Flood 00LV lamp 8' 8,000 4,000 4,000 7, LTV759 / LTV59 PAR36 00W Halogen 5 Very Narrow 00LV Spot lamp, ' 8' LTV759 / LTV59 PAR36 00W Halogen Wide Flood 00LV lamp 8' 4' 44 KIM LIGHTING

47 Photometrics LTV7 Series 4, , ,000.9, ,00,400,600 LTV7 Spot 8W LED ' 45' 5', LTV7NF Narrow Flood 8W LED ' 45' 5' LTV760 Series 4, , , ,000., ,000 3,00 4.0,00,400 LTV76 MR 0HAL ESX MR6 0W Halogen Narrow Spot LTV76 MR 0HAL BAB MR6 0W Halogen Flood 6,000 4,000 LTV76 MR 35HAL, FRB MR6 35W Halogen Narrow Spot,400,600 LTV76 MR 35HAL FRA MR6 35W Halogen Spot, , ,000..8, LTV76 MR 35HAL FMW MR6 35W Halogen Flood 8,000 6,000 4,000 LTV76 MR 50HAL, EXT MR6 50W Halogen Narrow Spot,400,800,00 LTV76 MR 50HAL EXZ MR6 50W Halogen Narrow Flood, LTV76 MR 50HAL EXN MR6 50W Halogen Flood KIM LIGHTING 45

48 Photometrics LTV760 Series, , , ,600 3,000..8, LTV76 MR 50HAL FNV MR6 50W Halogen Wide Flood ,000 3,000,000 LTV76 50HAL, PAR0 50W Halogen 9 Narrow Spot,400,800,00 LTV76 50HAL PAR0 50W Halogen 6 Spot, LTV76 50HAL PAR0 50W Halogen Flood,00, ' ',800, ' LTV767 Spot 6W LED ' 5' 5' LTV767NF Narrow Flood 6W LED ' 5' 5', LTV768WF Wide Flood 5W LED ' 8',00, ,500 6, ,050 3, ,000, ,400, LTV769 NF 0PMH T-4 0W Pulse Start in Narrow Flood 5,000 3,750,500 LTV769 0PMH, T-4 0W Pulse Start in Spot,700,05,350 LTV769 NF 35PMH T-4 35W Pulse Start in Narrow Flood 0,000 7,500 5,000 LTV769 35PMH, T-4 35W Pulse Start in Spot 46 KIM LIGHTING

49 Safety and Maintenance. Fixtures must be grounded in accordance with national, state, and/or local codes. Failure to do so may result in serious personal injury.. Extreme caution should be taken when fixtures are used in paved areas. High temperature lenses can burn feet, hands or objects inadvertently placed on top of fixtures. If fixtures must be used in paved areas, locate them away from normal pedestrian traffic, and use the lowest wattage lamp possible. 3. It is recommended that all conduit entries be sealed with RTV silicone to maintain a clean, dry splice compartment. 4. To maintain light efficiency and prevent fixture overheating, lenses must be kept clean and free of dirt, dust, leaves and trash. 5. Lightvault fixtures are not approved for any submersible installations including fountains, ponds, reflecting ponds or swimming pools. KIM LIGHTING 47

50 Lamp Guide Lamp Lamp Watts Example Manufacturer Designator ANSI Ballast Type Life (Hours) Lumens/ Candlepower Photometric Page Reference HALOGEN V V V PAR0 Medium Base 9 Narrow Spot 50 Philips 50PAR0/HAL/N9 n/a cp 46 6 Spot 50 Philips 50PAR0/HAL/6 n/a cp 46 Flood 50 Philips 50PAR0/HAL/NFL30 n/a cp 46 Medium Base Narrow Spot 0 Sylvania/Osram 0PAR/CAP//0 n/a cp 4, 4 5 Spot 0 Sylvania/Osram 0PAR/CAP/NF/5 n/a cp Wide Flood 0 Sylvania/Osram 0PAR/CAP/FL/30 n/a cp 4 9 Spot 50 Spot 50 General Electric Q50PAR/0 n/a cp 36, 39 Flood 50 General Electric Q50PAR/FL30 n/a cp 36, 39 T-4 Mini Can 50 37, 40, 43, 44 PAR36 Screw Term 5 Very Narrow Spot 50 General Electric 50PAR36/H/VN5 volt cp 43 8 Narrow Spot 50 General Electric 50PAR36/H/N8 volt cp Wide Flood 50 General Electric 50PAR36/H/WFL volt cp 43 5 Very Narrow Spot 36 Sylvania/Osram 36PAR36/CAP/VN volt cp 3 Narrow Spot 36 Sylvania/Osram 36PAR36/CAP/N volt cp 3 Wide Flood 36 Sylvania/Osram 36PAR36/CAP/WFL volt cp AR G53 4 Super Spot 35 Sylvania/Osram 35AR/4 /S volt cp 8 Spot 35 Sylvania/Osram 35AR/8 / volt cp 5 Flood 35 Sylvania/Osram 35AR/5 /FL volt cp 4 Narrow Spot 50 Sylvania/Osram 50AR/4 /S volt cp 8 Spot 50 Sylvania/Osram 50AR/8 / volt cp 5 Flood 50 Sylvania/Osram 50AR/5 /FL volt cp 8 Spot 75 Sylvania/Osram 75AR/8 / volt cp 5 Flood 75 Sylvania/Osram 75AR/5 /FL volt cp 8 Spot 00 Sylvania/Osram 00AR/8 / volt cp 43 5 Flood 00 Sylvania/Osram 00AR/5 /FL volt cp Wide Flood 00 Sylvania/Osram 00AR/45 /WFL volt cp 43 MR6 GX5.3 5 Narrow Spot (ESX) 0 General Electric 0MR6/N (ESX) volt cp 45 Flood (BAB) 0 General Electric 0MR6/FL (BAB) volt cp 45 Narrow Spot (FRB) 35 Sylvania/Osram 35MR6/N (FRB) volt cp 45 Spot (FRA) 35 General Electric 35MR6/ (FRA) volt cp 45 Flood (FMW) 35 General Electric 35MR6/FL (FMW) volt cp 45 5 Narrow Spot (EXT) 50 General Electric 50MR6/N (EXT) volt cp 45 5 Narrow Flood (EXZ) 50 General Electric 50MR6/NFL (EXZ) volt cp 45 Flood (EXN) 50 General Electric 50MR6/FL (EXN) volt cp Wide Flood (FNV) 50 General Electric 50MR6/WFL (FNV) volt cp 46 Narrow Spot (FPB) 65 Sylvania 65MR6/N/0 (FPB) volt cp 5 Narrow Flood (FPC) 65 Sylvania 65MR6/NFL/5 (FPC) volt cp Flood (FPB) 65 Sylvania 65MR6/FL/40 (FPB) volt cp Spot (EYF) 75 Philips 75MR6/0-EYF volt cp 36 Flood (EYC) 75 Philips 75MR6/FL36-EYC volt cp 48 KIM LIGHTING

51 Lamp Lamp Watts Example Manufacturer Designator ANSI Ballast Type Life (Hours) Lumens/ Candlepower Photometric Page Reference HIGH ESSURE SODIUM ED-7 Clear Medium Base PULSE START METAL HALIDE ED-7 Clear Medium Base 50 General Electric LU50/MED S lm General Electric LU70/MED S lm 35, 37, 38, General Electric LU00/MED S lm 35, 37, 38, 40, 4 50 General Electric LU50/MED S lm 35, 37, 38, Venture MH50U M Im 4, 43, Sylvania/Osram M70/U/MED M Im 35, 37-39, Sylvania/Osram M00/U/MED M Im 35, 37-39, 4 50 Sylvania/Osram M50/U/MED M Im 35, Medium Base 5 Spot 70 Philips CDM70// M cp 36, 38, 4, 44 Flood 70 Philips CDM70//FL M cp 36, 38, 4, Wide Flood 70 Philips CDM70//WFL M cp 36, 39, 4, 44 5 Spot 00 Philips CDM00// M cp 36, 39 Flood 00 Philips CDM00//FL M cp 36, Wide Flood 00 Philips CDM00//WFL M cp 36, 39 Spot 50 Sylvania/Osram MP50/U/0 M cp 36, Narrow Flood 50 Sylvania/Osram MP50/U/FL35 M cp 36, Very Wide Flood 50 Sylvania/Osram MP50/U/VWFL65/ECO M cp 36, 39 T-6 Clear G- Base 70 Philips CDM70 M , 37-39, Sylvania M , General Electric COMPACT FLUORESCENT 6PL PL PL LED 5 LED LED LED LED LED LED LED LED NOTE: For lamp/ballast information outside of the U.S.A. and Canada, please consult your local Kim representative. CAUTION: Fixtures must be grounded in accordance with national, state, and/or local electrical codes. Failure to do so may result in serious personal injury. Lamps by others. KIM LIGHTING 49

52 Lightvault Concealed In-grade Luminaire Because of a continuing product improvement program, Kim Lighting reserves the right to change specifications without notice. How may we serve you better? Let us know by visiting our web site at: Your input is valuable to us.

Lantern Era Bollard - LE Installation Instructions

Lantern Era Bollard - LE Installation Instructions P.O. Box 60080 16555 East Gale Ave. City of Industry, California 91716-0080 626/968-56 AX 626/330-3861 LE1 LE2 LE3 Lantern Era Bollard - LE Installation Instructions WARNING: Fixtures must be grounded

More information

A R C H I T E C T U R A L LO W L E V E L F LO O D L I G H T S E R I E S

A R C H I T E C T U R A L LO W L E V E L F LO O D L I G H T S E R I E S T A B L E O F C O N T E N T S A R C H I T E C T U R A L LO W L E V E L F LO O D L I G H T S E R I E S LLF755 - Low Level Flood with Anti-Glare Faceplate C1.1 LLF800 - Low Level Flood with Anti-Glare Faceplate

More information

TORNADOTM BOLLARD PATENTS PENDING

TORNADOTM BOLLARD PATENTS PENDING TORNADOTM BOLLARD PATENTS PENDING Day Tornado Bollard Unlike any bollard available in today s specification pallet, Tornado offers a new form and character for pedestrian scale lighting. Tornado adds an

More information

LANDSCAPE 12 / 120 VOLT. 12 Volt / 120 Volt. Landscape

LANDSCAPE 12 / 120 VOLT. 12 Volt / 120 Volt. Landscape LANDSCAPE 12 / 120 VOLT 12 Volt / 120 Volt Landscape C O M P R E H E N S I V E C A T A L O G KIM Landscape Lighting Kim Lighting is known throughout the world as the premier designer and manufacturer of

More information

25 Sign / Wall Lighter 4324 LED Series Extruded Aluminum, PicoPrism LED revision 9/9/15 kl_4324led_series_spec.pdf

25 Sign / Wall Lighter 4324 LED Series Extruded Aluminum, PicoPrism LED revision 9/9/15 kl_4324led_series_spec.pdf Type: Catalog number: / / Wattage / Lamp(s) Finish Options: See page 2 ing Options: See pages 3-5: Approvals: Date: Page: 1 of 5 Specifications ORDERING INFORMATION Light Engine Length l 4324P70 / 16L3KUV

More information

ORDERING INFORMATION: 120 Volts (120)

ORDERING INFORMATION: 120 Volts (120) Bull38 A weather tight unit fabricated from durable grade die-cast aluminum & fully sealed, gasketed glass lens. Mount: 1/2 threaded adjustable knuckle mount Porcelain medium base socket Thermoset polyester

More information

AFL FLOODLIGHT SERIES

AFL FLOODLIGHT SERIES AFL FLOODLIGHT SERIES A FL Flood Lighting for Hazardous Locations Class I, Division 2, Groups A, B, C & D UL 844 Hazardous Locations UL 598A Marine Outside Type Zone 2, Groups IIA, IIB & IIC CUL Cast Aluminum

More information

C A M B E RTM PATENTS PENDING

C A M B E RTM PATENTS PENDING C A M B E RTM PATENTS PENDING DAY CAMBER TM Camber is designed to be seen both day and night. Its daytime form is an eclectic blend of curvilinear and rectilinear lines accentuated by structurally expressive

More information

SOURCE TE- Electronic MH. OPTIONS See Below OPTIONS. L = Lamped BLANK = General Purpose Optics A = Asymmetric Optics S = Spot

SOURCE TE- Electronic MH. OPTIONS See Below OPTIONS. L = Lamped BLANK = General Purpose Optics A = Asymmetric Optics S = Spot CATALOG NO. TYPE NO. JOB NAME -8 GP Flood Series Floodlighting GP (Mini) ORDERING INFORMATION Catalog Number: Example: GPA070TEL GP A TE SERIES GP-General Purpose Flood SIZE -Mini ACCESSORIES GPGS = Visor

More information

H700 H710 H720. Compact Flood. Typical Applications. Features. Lamp Types. Approvals SPECIALTY LANDSCAPE

H700 H710 H720. Compact Flood. Typical Applications. Features. Lamp Types. Approvals SPECIALTY LANDSCAPE Compact Flood H00 H0 H0 ECIALTY LANDSCAPE Typical Applications Sculptures Statues Courtyards Building Facades Architectural Details Night Gardens Signage Features Beam Control Glare Control Color Control

More information

New X Series Centaurs

New X Series Centaurs New X Series Centaurs In-grade CSA Listed Wet Label IP68 CX 2/14 C1X In-Ground LED Fixture IP68. Cast stainless steel body 304 alloy. 1W Cree XPE LED. On-board electronics for 24V DC and 0-10V dimming.

More information

220/230/240V Watt High Pressure Sodium - Hazardous Location Lighting - C1D2 - Pole Mount

220/230/240V Watt High Pressure Sodium - Hazardous Location Lighting - C1D2 - Pole Mount 220/230/240V Watt High Pressure Sodium - Hazardous Location Lighting - C1D2 - Pole Mount Part #: HAL-PRM-250W-HPS-220V-PT Page: 1 Made in the USA The efficient HAL-PRM-250W-HPS-220V-PT high pressure sodium

More information

Landscape LED 12V/120V/277V. LED Collection. Outdoor Landscape Luminaires. All-Inclusive LED Collection

Landscape LED 12V/120V/277V. LED Collection. Outdoor Landscape Luminaires. All-Inclusive LED Collection Landscape LED //277V LED Collection Outdoor Landscape Luminaires All-Inclusive LED Collection LED Collection STEP LIGHTS Round Rectangle IN-GRADE UPLIGHTS Minivault Lightvault ACCENT FLOOD MicroFlood Scarab

More information

Architectural Floodlights Watt

Architectural Floodlights Watt ARCHITECTURAL FLOOD CFL AFL1/2/3 Architectural Floodlights 5-1 Watt CFL AFL1 AFL2 AFL3 Architectural Floodlights Table of Contents Architectural Floodlights 2-94 Floodlighting Application 2-19 Optical

More information

3900 BOLLARD SERIES.

3900 BOLLARD SERIES. BY 3900 BOLLARD SERIES The 3900 Bollard Series was designed to light landscapes, pathways and high traffi c areas. The bollards feature lamp housings that minimize water and dust infi ltration, keeping

More information

RDB-RDS. Corrosion Proof Composite Uplights

RDB-RDS. Corrosion Proof Composite Uplights RDB-RDS Corrosion Proof Composite Uplights Lighting Designer-Kennedy/Reeder, Photographer-Vance Roth Lighting Designer-Ross DeAlessi, Photographer-James F.Wilson Lighting Designer-Schuler & Shook, Photographer-Mark

More information

A R C H I T E C T U R A L WA L L L U M I N A I R E S E R I E S

A R C H I T E C T U R A L WA L L L U M I N A I R E S E R I E S T A B L E O F C O N T E N T S A R C H I T E C T U R A L WA L L L U M I N A I R E S E R I E S WL700R - Wall Luminaire with Open Faceplate G2.1 WL730R - Wall Luminaire with Cross Bar G2.2 WL755R - Wall Luminaire

More information

Landscape Lighting Collection. Accent, Path & In-Grade Lighting

Landscape Lighting Collection. Accent, Path & In-Grade Lighting Landscape Lighting Collection Accent, Path & In-Grade Lighting Landscape Lighting Collection Contents: Timeless Values 1 Quality & Performance 2-3 Scarab 4-5 MicroFlood 6 Bell Wall 7 Ravenna Lowighter

More information

part number description number per fixture

part number description number per fixture MACs - M9400 SERIES spare PARTS LIST MACS - M9400 SERIES A B C D E G H J F part number description number per fixture A CLB9400... Clamp Band........................................................ 1 B

More information

AerolumeTM. Collection. Area Luminaires 3 Fixture Sizes W HID 64/80/120

AerolumeTM. Collection. Area Luminaires 3 Fixture Sizes W HID 64/80/120 Aerolume Collection Area Luminaires Fixture Sizes 70-00W HID 64/80/ Overview Mini-Aerolume Aerolume Aerolume-G 1." (4.9mm) 18" (47.mm) " (84.mm) 6." (16.1mm) 19" (48.6mm) 4" (1.4mm) 8" (0.mm) " (84.mm)

More information

Series Optics Mounting Lamping Finish Voltage. H039T6 1 39wT6 H w. H w. (T6 only available with MA and MS refractors) 12 3 /8" (314mm)

Series Optics Mounting Lamping Finish Voltage. H039T6 1 39wT6 H w. H w. (T6 only available with MA and MS refractors) 12 3 /8 (314mm) Project: Type: Qty: TC _ Series Optics Mounting Lamping Finish Voltage _ Options Series TC Triangular Column Optics Height Lamping Finish Voltage Options MA Type III MTR 5* Refractor MS Type V MTR 5* Refractor

More information

CC/CCS21 21" Post Top Mounted, Curvilinear, LED revision 5/9/11 kim_cc21pled_spec.pdf

CC/CCS21 21 Post Top Mounted, Curvilinear, LED revision 5/9/11 kim_cc21pled_spec.pdf Catalog number: Approvals: / / / / Mtg. Fixture Electrical Module Finish Options See page 4 See page 2 See page 3 Select pole from Kim Arms and Poles Selection Guide. If pole is provided by others indicate

More information

Low brightness and uplighting combine to create a pleasing visual environment. Softbay Series

Low brightness and uplighting combine to create a pleasing visual environment. Softbay Series Low brightness and uplighting combine to create a pleasing visual environment Softbay Series Keene MAKES LIGHT WORK Softbay is a durable performer in light-to-moderate industrial environments and an enduring

More information

FCW3043 ADA FCW3045 ADA FCW3042 ADA FCW3040 ADA

FCW3043 ADA FCW3045 ADA FCW3042 ADA FCW3040 ADA FCW3043 2.5 in FCW3045 2.3 in FCW3042 2.3 in FCW3040 2.2 in 120 www.fclighting.com *Consult website for updated specification sheets regarding detailed information and performance. FC Lighting, Inc. 2012.

More information

Laredo Decorative Wallpack Family

Laredo Decorative Wallpack Family Outdoor Lighting Laredo Decorative Wallpack Family NEW Selections Full Cutoff IDA Compliant Laredo Application Guide Compact LCC 6-1ft mounting height The Laredo Family meets the Strictest Lighting Codes

More information

DESCRIPTION Galleria's beauty and versatility make it an excellent choice for roadway and general area lighting applications. An aesthetic reveal in the formed aluminum housing gives the Galleria a distinctive

More information

C O N T R A S T NORTH STAR LIGHTING INC. A R C H I T E C T U R A L F L O O D L I G H T S E R I E S

C O N T R A S T NORTH STAR LIGHTING INC. A R C H I T E C T U R A L F L O O D L I G H T S E R I E S C O N T R A S T A R C H I T E C T U R A L F L O O D L I G H T S E R I E S T h e w i d e s t p o s s i b l e r a n g e o f a r c h i t e c t u r a l f l o o d l i g h t s Versatility - For the first time,

More information

LUMENTON. including poured concrete. Suitable for installation within 4 feet of ground. Product specifications subject to change without notice.

LUMENTON. including poured concrete. Suitable for installation within 4 feet of ground. Product specifications subject to change without notice. WSV600 Wall Luminaire with Open faceplate 2007.4.13 Applications: Oval Surface Wall Sconce Luminaires are ideal for indoor or outdoor applications in, residential, commercial, or architectural installations

More information

SITE /ROADWAY BNS SERIES. Bounce. Pedestrian Scale Luminaire W H.I.D.

SITE /ROADWAY BNS SERIES. Bounce. Pedestrian Scale Luminaire W H.I.D. SITE /ROADWAY BNS SERIES Bounce Pedestrian Scale Luminaire 70-200W H.I.D. Bounce Table of Contents Relativity 2-3 Horizontal or Vertical Lamp 4 Design Features 5 Ordering Information 6 Luminaire Specifications

More information

ORDERING INFORMATION: 120 Volts (120) 208 Volts (208) 240 Volts (240) 277 Volts (277) 480 Volts (480)

ORDERING INFORMATION: 120 Volts (120) 208 Volts (208) 240 Volts (240) 277 Volts (277) 480 Volts (480) Del Mar Corrosion resistant, Weather Tight Unit fabricated from spun Aluminum.080 Thick, Full Gasket Keeps out insects and Water. Lens & Removable Door Assembly: Hinged Door Assembly Formed from One Piece

More information

Overall Dimensions. Specifications

Overall Dimensions. Specifications Overall Dimensions EFI Mastfitter Mount (MA2) (standard) A 70-400W HID unit: 13 Housing A B C 13.3 11.3 23.3 (33.78cm) (28.70cm) (59.18cm) 750-1000W HID and 85-165W QL unit: 19 Housing A B C 19.4 14.9

More information

Options. Pole and Arm. Suitable for wet locations

Options. Pole and Arm. Suitable for wet locations Catalog number: / / / Mtg. Fixture Electrical Module Finish See page 2 See page 3 Options Pole and Arm Select pole from Kim Arms and Poles Selection Guide. If pole is provided by others indicate O.D. for

More information

Areamaster 100 Wide-Beam Floodlights 70 W, 100 W, 150 W HPS; 70 W, 100 W, 150 PSMH For general, marine and hazardous locations.

Areamaster 100 Wide-Beam Floodlights 70 W, 100 W, 150 W HPS; 70 W, 100 W, 150 PSMH For general, marine and hazardous locations. Areamaster 100 Wide-Beam Floodlights NEC CEC V Class II, Divisions I and 2, Groups E, F, G V Class III Applications Highly efficient, all-weather flood-lighting for lower wattage service. Well suited for:

More information

PGL350P W PS Wallpack

PGL350P W PS Wallpack 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 PGL350P1281 350W PS Wallpack Hubbell Lighting, Inc. Catalog Number Manufacturer Description Weight per unit Product Category

More information

DECORATIVE. Tear Drop Series

DECORATIVE. Tear Drop Series DECORATIVE Tear Drop Series D ECORATIVE Product Catalog Tear Drop Series Styled to replicate the tear drop luminaires that illuminated boulevards during the first half of the century, the Holophane Tear

More information

Laredo - Decorative Wallpack Family

Laredo - Decorative Wallpack Family Outdoor Lighting Laredo - Decorative Wallpack Family Full Cutoff New Laredo Application Guide Compact LCC 6-1ft mounting height The Laredo Family meets the strictest lighting codes Full Cutoff Star View

More information

The Premium Choice in Landscape Lighting

The Premium Choice in Landscape Lighting The Premium Choice in Landscape Lighting Lighting that defines your style Low Voltage Accent Create dramatic effects that make a home and landscape come alive at night. Versatility, multiple usage options,

More information

LITON FLOOD / SPOT O U T D O O R A D J U S T A B L E L I G H T I N G

LITON FLOOD / SPOT O U T D O O R A D J U S T A B L E L I G H T I N G LITON L I G H T I N G O U T D O O R A D J U S T A B L E FLOOD / SPOT L I G H T I N G ABOVE GRADE O U T D O O R L I G H T I N G The AG-series ground and wall mount luminaires are designed for general landscape

More information

Perimaliter Wallpacks

Perimaliter Wallpacks Perimaliter Wallpacks Perimaliter III PVL3 / PGM3 Perimaliter II PGL Solutions for Perimeter/Area Lighting Perimaliter Wallpacks The Perimaliter wallpack has been the design leader in refractor wallpacks

More information

Overall Dimensions. Specifications

Overall Dimensions. Specifications Overall Dimensions EFX B EFX VM Vertical Mount C 13 housing (70-400W) 19 housing (450-1000W) E D H B C D E 13.3 16.8 16.2 7.0 9.8 (33.78cm) (42.67cm) (41.15cm) (17.78cm) (24.89cm) F G H I J 22.2 11.3 6.3

More information

2018 NEW PRODUCT SUPPLEMENT

2018 NEW PRODUCT SUPPLEMENT 2018 NEW PRODUCT SUPPLEMENT HARDSCAPE WITH DUAL CCT AND INTEGRAL BRIGHTNESS CONTROL Transformer For 12V Grand Accent, Accent, Mini Accent, Mini Wall Wash and Dual CCT Hardscape IP65 Rated 12V to 15V taps

More information

Areamaster 1000 Floodlights Integrally Ballasted W HID For hazardous locations.

Areamaster 1000 Floodlights Integrally Ballasted W HID For hazardous locations. A, IIB, IIC Applications Powerful, efficient weatherproof lighting for large areas such as: Pulp and paper mills Processing plants Chemical plants Oil refineries Foundries Storage areas Waste and sewage

More information

1000 Watt Metal Halide Light - Class 1 Division 2 Groups A-D - T3b Temperature - 110,000 lumens

1000 Watt Metal Halide Light - Class 1 Division 2 Groups A-D - T3b Temperature - 110,000 lumens 1000 Watt Metal Halide Light - Class 1 Division 2 Groups A-D - T3b Temperature - 110,000 lumens Part #: HALPRM-1000WMH Made in the USA The extremely durable Larson Electronics HALPRM-1000WMH metal halide

More information

Pole Series. Series Reflector Lens Mounting Lamping Finish Voltage. S w S w S w S w

Pole Series. Series Reflector Lens Mounting Lamping Finish Voltage. S w S w S w S w Type: Qty: QHO Series Reflector Lens Mounting Lamping Finish Voltage QHO Quadro HO R Type II Aluminum reflector R5 Type V Aluminum reflector L S Project: Flat Glass Sagged Glass Series Reflector Lens Mounting

More information

CALL TODAY!

CALL TODAY! DIRECT LIGHTING MFG. Serving Your Business, Mapping our Future To Our Valued ers: In today s uncertain economy your customers are looking to save Money with quality alternatives, we are the right source

More information

UV16 vandal resistant, wet/damp location emergency lighting

UV16 vandal resistant, wet/damp location emergency lighting UV16 vandal resistant, wet/damp location emergency lighting 120/277 VAC, 60 Hz dual voltage input Maintenance-free, sealed lead calcium battery Molded from high-impact polycarbonate Simplified installation

More information

WPP25 250W MP Wal-Pak Borosilicate Glass Hinged/Removabl

WPP25 250W MP Wal-Pak Borosilicate Glass Hinged/Removabl 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 WPP25 250W MP Wal-Pak Borosilicate Glass Hinged/Removabl Catalog Number Manufacturer Description Weight per unit Product

More information

L Listed FEATURES. Series Lamps Wattage # of Lamps ICR= remote fixture 7= 7.2 watts. L Listed. Phantom TM FEATURES

L Listed FEATURES. Series Lamps Wattage # of Lamps ICR= remote fixture 7= 7.2 watts. L Listed. Phantom TM FEATURES ICR-2 Remote Series FEATRES The ICR-2 Series remote emergency lighting fixture features a contemporary, elegant design in a compact thermoplastic housing. Attractive and versatile, the ICR-2 Series fixtures

More information

1000 Watt Metal Halide Flood Light - 110,000 Lumens - Slipfitter Mount - 120~277 Volts AC

1000 Watt Metal Halide Flood Light - 110,000 Lumens - Slipfitter Mount - 120~277 Volts AC 1000 Watt Metal Halide Flood Light - 110,000 Lumens - Slipfitter Mount - 120~277 Volts AC Part #: MHFL-1000W Made in the USA The powerful and efficient MHFL-1000W metal halide light fixture from Larson

More information

Predator Medium Floodlight Wet Location

Predator Medium Floodlight Wet Location Predator Medium Floodlight Wet Location Installation and Maintenance Manual AFTER INSTALLATION DELIVER THIS MANUAL TO OWNER IMPORTANT SAFETY INSTRUCTIONS -READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING

More information

Dual Lamp Ceramic Metal Halide 3 Lumen Packages in 1 Luminaire

Dual Lamp Ceramic Metal Halide 3 Lumen Packages in 1 Luminaire Dual Lamp Ceramic Metal Halide 3 Lumen Packages in 1 Luminaire For additional configurations see our Product Catalog or visit our website at WINDIRECT TM 3 in1 Dual Lamp Ceramic Metal Halide CMH x 2 1

More information

HALO. Track Lighting. Metal Halide + Track = STASIS. Stasis Metal Halide

HALO. Track Lighting. Metal Halide + Track = STASIS. Stasis Metal Halide HALO Metal Halide + Track = STASIS Track Lighting Stasis Metal Halide Stasis Features Stasis Ceramic Metal Halide = The Sharp NEW Reliable Workhorse Halo once again sets the new standard in Ceramic Metal

More information

Hubbell Lighting s ExpressLine family

Hubbell Lighting s ExpressLine family Hubbell Lighting s ExpressLine family Value & Service for you and your customers! ExpressLine by Hubbell Lighting The name Hubbell has long been associated with quality products sold through the Electrical

More information

TUBE. Precise construction encourages reliable IP rating. Bi-directional light output with single light source. Choices of light distribution angles.

TUBE. Precise construction encourages reliable IP rating. Bi-directional light output with single light source. Choices of light distribution angles. TUBE TUBE TUBE family is available in 4 different sizes. They are protected from the ingress of dust and water and are used in both outdoor and indoor environments. Operating with PAR, Compact Fluorescent,

More information

Driver Info. Construction Thermal Management: Superior thermal management with die-cast aluminum heatsink. Ambient Temperature:

Driver Info. Construction Thermal Management: Superior thermal management with die-cast aluminum heatsink. Ambient Temperature: WP3LED55 Project: Type: Prepared By: Date: 82W, 65W and 55W LED wallpacks. Available with up to 9,000 lumens and 121 LPW. Up to 100,000 hour L70 lifespan. 5-Year Warranty. Color: Bronze Weight: 16.8 lbs

More information

GATEWAY ARCHITECTURAL LIGHTING APPEARANCE PERFORMANCE ENDURANCE

GATEWAY ARCHITECTURAL LIGHTING APPEARANCE PERFORMANCE ENDURANCE GATEWAY ARCHITECTURAL LIGHTING APPEARANCE PERFORMANCE ENDURANCE GATEWAY ARCHITECTURAL LIGHTING The Gateway Architectural Lighting Series offers a variety of styles designed to accent architectural settings

More information

HALO H7T. 6" RECESSED DOWNLIGHTING Incandescent

HALO H7T. 6 RECESSED DOWNLIGHTING Incandescent 6" RECESSED DOWNLIGHTING Incandescent 6" Aperture Non-IC Ceiling 120V Line Voltage RECESSED DOWNLIGHTING Thermally Protected Housing Insulation must be kept 3" from all sides of the housing For use with

More information

STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY SPECIFICATIONS FOR HIGH PRESSURE SODIUM LUMINAIRES HIGH MAST TYPE

STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY SPECIFICATIONS FOR HIGH PRESSURE SODIUM LUMINAIRES HIGH MAST TYPE STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625 SPECIFICATIONS FOR HIGH PRESSURE SODIUM LUMINAIRES HIGH MAST TYPE N.J. Specification No. Effective Date: July 1, 2001 New Jersey

More information

LED LIGHTING VISIT FOR MORE INFORMATION OUR LIGHTING PRODUCT SERIES

LED LIGHTING VISIT   FOR MORE INFORMATION OUR LIGHTING PRODUCT SERIES OUR LIGHTING PRODUCT SERIES Wall Pack Full Cutoff Wall Pack Wall Mount Canopy Troffers Exit Lights Area Light Flood Light Linear High Bay Vapor Tight Linear Fixture And More! 443 GREENBRIAR DR. STAFFORD,

More information

IMPACT FLOODLIGHT Architectural Flood Luminaire

IMPACT FLOODLIGHT Architectural Flood Luminaire IMPCT FLOODLIGHT rchitectural Flood Luminaire CLSSIC FORM + C O N T E M P O R R Y F E T U R E S ppealing round-back form combined with innovative design features make the Impact Flood series a best in

More information

LED STEP LIGHT LED Forms

LED STEP LIGHT LED Forms LED STEP LIGHT LED Forms OUTDOOR INDOOR Inspiration will come in abundance once you try our LED accent step lights. Use them outdoors on your deck or on the stairs inside of your home. You will be truly

More information

esconce mini esconce TM Architectural Area Lighting

esconce mini esconce TM Architectural Area Lighting esconce mini esconce TM Architectural Area Lighting to create, inspire and nurture excellence in each other Exterior grade sconces with unmatched design flexibility and lighting performance. esconce ENERGY

More information

Industrial and Commercial Indoor Parking and Area Security Lighting Floodlighting Sports Lighting HID Controls

Industrial and Commercial Indoor Parking and Area Security Lighting Floodlighting Sports Lighting HID Controls Industrial and Commercial Indoor Parking and Area Security Lighting Floodlighting Sports Lighting HID Controls Makes Light Work Solid, job-ready performers, lighting our work and leisure environments,

More information

KEPLERO ZOOM RGBW Flexibility

KEPLERO ZOOM RGBW Flexibility W Flexibility Professional Inground LED Fixture Concept: Professional addressable DMX 512 controlled RGBW LED fully adjustable inground recessed LED fixture. Housing: 8 tall x 11 diameter die-cast aluminum

More information

HAZARDOUS LOCATION CLASSIFIED AREAS LW1 AND LW2 SERIES DOWN OR UP OPTICS

HAZARDOUS LOCATION CLASSIFIED AREAS LW1 AND LW2 SERIES DOWN OR UP OPTICS H6..H Project: Fixture Type: Location: Contact/Phone: FINIA LED WALL MOUNTED HAZARDOUS LOCATION CLASSIFIED AREAS LW AND LW SERIES DOWN OR UP OPTICS LED W, W, AND 8W PRODUCT DESCRIPTION The Finia LED LW

More information

Height Finish Pole Options. Mounting Lamping Finish Voltage. Metal Halide. Single. H w H070 70w H w H w 15 1 /4" (387mm) 15 3 /4"

Height Finish Pole Options. Mounting Lamping Finish Voltage. Metal Halide. Single. H w H070 70w H w H w 15 1 /4 (387mm) 15 3 /4 Vektor Project: Series Reflector Mounting Lamping Finish Voltage VE Vektor R Type II Aluminum Reflector Single R5 Type V Aluminum Reflector Double M Single ' Arm M Double ' Arm W Wall T Single Fitter Type:

More information

The Archetype LED with PicoEmitter. Altitude LED with PicoPrism. The Archetype HID. WARP9 LED with PicoPrism. ARFX09 - ArcheType X Flood

The Archetype LED with PicoEmitter. Altitude LED with PicoPrism. The Archetype HID. WARP9 LED with PicoPrism. ARFX09 - ArcheType X Flood ARX09 - ArcheType X Site/Area A r c h e Ty p e X A d v a n t a g e adjustment ARX09QS Type III Type V L Left R Right K 0 Voltages Dark Bronze Color Temp. Drive Current K 000K 0 0 0 70 0mA 00mA 0mA 00mA

More information

Auto Dealership Solution

Auto Dealership Solution Auto Dealership Solution Area Light Flood light Wall Pack Controls High Bay Downlight Troffer &Troffer Retroffer Kit Flat Panel ENERGY COST SAVING LED is a highly energy efficient lighting technology,

More information

KEPLERO MINI HE Efficiency & Interchangeability

KEPLERO MINI HE Efficiency & Interchangeability KEPLERO MINI HE Efficiency & Interchangeability Professional Inground LED Fixture Concept: Compact high performance inground single source COB LED fixture with 3 different fixed optic beam options and

More information

ENERGY SAVING PRODUCTS LIGHTING

ENERGY SAVING PRODUCTS LIGHTING ENERGY SAVING PRODUCTS LIGHTING POLYCARBONATE WALL PACK JWP2/42CFLMVPC PK 2 X 42W PLT CFL 120 277V 50/60Hz Electronic GX24q4 6400 14 3/8 12 7 1/4 1 pc. 9.4 lbs. 0.95 cft. Ideal for Security and Perimeter

More information

PRECISION ARCHITECTURAL LIGHTING 8000 SERIES

PRECISION ARCHITECTURAL LIGHTING 8000 SERIES PRECISION ARCHITECTURAL LIGHTING 8000 SERIES PRECISION, POWER AND PERFORMANCE. Expertise in sealing technology and heat transfer provides compact, high-wattage luminaries with the highest ingress protection

More information

use pulldowns to assign fixture # to arm locations: K K K 14W LED 27W LED 1 Full-Cutoff optics

use pulldowns to assign fixture # to arm locations: K K K 14W LED 27W LED 1 Full-Cutoff optics Lines 2, 3 and 4 and line quantities applicable to SSx mounting only Project: Type: Qty: FIT # qty SERIES - OPTICS - MOUNTING - LIGHT ENGINE - CCT - FINISH - VOLTAGE - ACCESS.1 - ACCESS.2 1 OLML- - - -

More information

1351 Reflex. Ordering Format for 1351 Housing only Choose one from each category SERIES 1351 MWR SHOWN WITH 1351A DTS WH TRIM 4-14

1351 Reflex. Ordering Format for 1351 Housing only Choose one from each category SERIES 1351 MWR SHOWN WITH 1351A DTS WH TRIM 4-14 4" 3¹ ₂" 10" 9¹ ₂" WALL WASH INDIRECT 45 RANGE OF MOTION MOUNTING OPTIONS 1351 SINGLE MR16 REFLEX CEILING OR WALL MOUNTED RECESSED FIXTURE Order Housing and Trim Accessory separately 1351A Trim Accessory

More information

BetaLED Recessed Canopy Luminaires

BetaLED Recessed Canopy Luminaires CAN-227-5M-RM "A" 8.8in [225mm] Driver Housing 350 ma HL option, 525mA, 700mA DIM A 12.8" [325mm] 23.8" [605mm] Fixture DIM B DIM C 90 LED 21.6" [549mm] 20.6" [523mm] 120 LED 26.2" [665mm] 25.125" [638mm]

More information

LED LINEAR QUICK SUMMARY CO W SI MODEL CORTANA

LED LINEAR QUICK SUMMARY CO W SI MODEL CORTANA LED LINEAR CORTANA This simple and elegant suspended LED linear light with wide optics is ideal for general uniform ambient lighting applications where clean, modern architectural design is required. Use

More information

9 4 L I N E R E C E S S E D S T E P & A I S L E L I G H T I N G

9 4 L I N E R E C E S S E D S T E P & A I S L E L I G H T I N G 9 L I N E R E C E S S E D S T E P & A I S L E L I G H T I N G GARDCO L I G H T I N G The Gardco 9 Line is an altogether fresh approach to the once utilitarian world of low-level lighting. By introducing

More information

Saturn Cutoff. Order Code: Pole Order Code: Series Height Finish Options. Customer: Date: Project: Qty: Type: SAC Saturn Cutoff SAC

Saturn Cutoff. Order Code: Pole Order Code: Series Height Finish Options. Customer: Date: Project: Qty: Type: SAC Saturn Cutoff SAC Date: Customer: Project: Type: Qty: Saturn Cutoff Order Code: SAC - - - - - - - - SAC Series SAC Saturn Cutoff Pole Order Code: - - - Series Height Finish Options Optics R Type II Distribution R Type V

More information

4DS 4.5 Downlight Square

4DS 4.5 Downlight Square CATALOG #: 4-1/2 5-1/2 TYPE: PROJECT: NEW CONSTRUCTION AND REMODEL FEATURES Tunable white from 2700K to 5000K CCT, minimum 80 CRI 4 inch aperture is unobtrusive in small scale spaces Square shape accentuates

More information

OP2 CosmoPolis Series

OP2 CosmoPolis Series Catalog Number: Approvals: - - - - - Series/Source-Wattage Optics E ballast Voltage Mounting Options Finish (Factory Installed) Accessories (Field Installed) Date: Page of 6 Overall Dimensions OP2 arm

More information

FC Well Light. Quick Facts. LED Well Lights. LED Well Lights

FC Well Light. Quick Facts. LED Well Lights. LED Well Lights LED Well Lights LED Well Lights PROJECT CATALOG # TYPE NOTES Ring (RG) Cowling (CW) Wash (GW) Louver (LV) FC Well Light DESIGNER PREMIUM Cylindrical in-grade fixture with versatile faceplate options in

More information

The Premier Brand of All Star Lighting

The Premier Brand of All Star Lighting The Premier Brand of All Star Lighting Luxrite features a full line of energy-efficient LED bulbs and fixtures for electrical supply houses and lighting suppliers across the continental U.S. Known for

More information

HOLOPHANE Outdoor Lighting

HOLOPHANE Outdoor Lighting 68 Sign Lighting Signs have two purposesto attract attention and to convey a message. And during nighttime hours, sign lighting must provide visibility and legibility to deliver the appropriate message.

More information

KAD250MR3TBSPD04 Wall Fixture

KAD250MR3TBSPD04 Wall Fixture 8 South Street 796-76, TX Nacogdoches Phone: 96-69-79 Fax: 96-6-68 AllenWatson@elliottelectric.com MRTBSPD Wall Fixture Catalog Number MRTBSPD Manufacturer Description Area Light, Metal Halide Lamp; Lamp

More information

Project: 1 IP65 Rated fixtures are rated for use outdoors where exposed directly to water from rain or irrigation.

Project: 1 IP65 Rated fixtures are rated for use outdoors where exposed directly to water from rain or irrigation. Catalog Number: Type: Project: Comments: Date: LED Flood Series FL1 Knuckle Mount The LED Flood Series is a family of energy efficient solutions for replacing high wattage outdoor flood luminaires. Their

More information

Meridian DETAILS CA10T4A CA10T4D CA13T4A. IP66 EPA: 2.2 FT 2 Weight: 27 lbs - 12 kg

Meridian DETAILS CA10T4A CA10T4D CA13T4A. IP66 EPA: 2.2 FT 2 Weight: 27 lbs - 12 kg Meridian Meridian DETAILS The elegant modular design of the MERIDIAN series allows adaptability to all surroundings and perfect integration with many different environments. Composed of cast and extruded

More information

Areamaster LED Flood/High Bay Luminaires

Areamaster LED Flood/High Bay Luminaires Applications Typical applications include: Pulp and paper mills Processing plants Chemical plants Oil refineries Foundries Storage areas Waste and sewage treatment Parking garages Other areas where dust,

More information

DE Down Light. Quick Facts. LED Down Lights. Straight Shroud

DE Down Light. Quick Facts. LED Down Lights. Straight Shroud LED Down Lights PROJECT CATALOG # TYPE NOTES Straight Shroud DE Down Light DESIGNER PLUS Practical directional down light in 1, 3, 6, or 9 LED. Aluminum construction. An RGBW version is also available

More information

The Premier Brand of All Star Lighting

The Premier Brand of All Star Lighting The Premier Brand of All Star Lighting Luxrite features a full line of energy-efficient LED bulbs and fixtures for electrical supply houses and lighting suppliers across the continental U.S. Known for

More information

31 SERIES Modular area fixtures. Replaces: 1000W HID

31 SERIES Modular area fixtures. Replaces: 1000W HID Replaces: 1000W HID Product Life: 75,000 hours Optic Lens: Borosilicate Glass 31 SERIES Modular area fixtures Neptun's LED parking lot /area fixtures combine architectural form and versatility to make

More information

TS-350 Fully-Flush Under Vehicle Inspection Light Packages

TS-350 Fully-Flush Under Vehicle Inspection Light Packages General Description The flush-mounted fixture is designed to aid security and safety inspectors by providing high-intensity illumination of vehicle undercarriages. Features include outstanding durability,

More information

ExceLine 1611 Clovis R. Barker Road San Marcos, TX Fax: PT#: EXSP072A0812

ExceLine 1611 Clovis R. Barker Road San Marcos, TX Fax: PT#: EXSP072A0812 Type No. Catalog No. Job. Name WL Series APPLICATIONS Applications include low ceiling applications, light industrial manufacturing facilities, offices, lobbies, conference rooms, food processing plants,

More information

SV10 LED. The US manufactured SV10 LED is. SV10 LED technical specifications

SV10 LED. The US manufactured SV10 LED is. SV10 LED technical specifications The US manufactured SV10 LED is the brightest thru hull LED underwater light available to owners of GRP and wood boats. The industry leading SV10 combines the unique qualities of the latest high density

More information

50 WATT PHILIPS ALR CELL (50ALR) HP holder provided (required) volt. LH less holder

50 WATT PHILIPS ALR CELL (50ALR) HP holder provided (required) volt. LH less holder V/A 6¹ ₈" 12¹ ₈" 50W PHILIPS ALR/ 50W OSRAM AR70 1611-1616 7" 13" 1622 1600 V/A 1600 V/A MULTI LAMP DOWNLIGHTS WITH 50 WATT OSRAM AR70 AND 50 WATT PHILIPS ALR LAMPS 12 volt lamp specification: 50 watt

More information

Perimaliter Wallpacks

Perimaliter Wallpacks ENERGY SAVING Outdoor Lighting Perimaliter Wallpacks Perimaliter III PVL3 / PGM3 Perimaliter II PGL Solutions for Perimeter/Area Lighting Perimaliter Wallpacks The Perimaliter wallpack has been the design

More information

ColorBlast RGB Powercore gen4 - Customizable exterior LED flood luminaire with intelligent color light

ColorBlast RGB Powercore gen4 - Customizable exterior LED flood luminaire with intelligent color light Lighting ColorBlast RGB Powercore gen4 - Customizable exterior LED flood luminaire with intelligent color light ColorBlast Powercore gen4 RGB ColorBlast Powercore gen4 high-performance LED luminaires combine

More information

WELLGLASS EV.. Series - H.I.D. well glass lighting fixture. Aluminium with low content of copper. O-ring made of Nitrile Rubber (NBR)

WELLGLASS EV.. Series - H.I.D. well glass lighting fixture. Aluminium with low content of copper. O-ring made of Nitrile Rubber (NBR) WELLGLASS EV.. Series - H.I.D. well glass lighting fixture EV.. series well glass lighting fixtures are suitable for hazardous areas of industrial plants for lighting of indoor and outdoor structures,

More information

ecolor Burst Powercore Architectural and landscape LED spotlight with solid color light

ecolor Burst Powercore Architectural and landscape LED spotlight with solid color light Architectural and landscape LED spotlight with solid color light Architectural and landscape LED spotlight with solid color light is a high-output, exterior-rated LED lighting luminaire designed for accent

More information

Hubbell Lighting Expressline Family 2009

Hubbell Lighting Expressline Family 2009 Hubbell Lighting Expressline Family 2009 LIGHTING SOLUTIONS ExpressLine by Hubbell Lighting The name Hubbell has long been associated with quality products sold through the Electrical Distribution Channel.

More information

APPENDIX B: LISTS OF APPROVED MATERIALS

APPENDIX B: LISTS OF APPROVED MATERIALS APPENDIX B: LISTS OF APPROVED MATERIALS APPENDIX B: LISTS OF APPROVED MATERIALS B1 Street Lighting MAY 2016 APPENDIX B1 STREETLIGHTING MATERIAL LIST 1.0 LIGHTING 1.1 Electrical Handholes CSA Precast concrete

More information

Table of Contents - Page 1 of 2

Table of Contents - Page 1 of 2 Bulletin 07VR Table of Contents - Page 1 of 2 Catalog Introduction & Product Features 2 Products: Specifi cations, Performance and 4-3 Kirlin Effi ciency & Performance 3 Hallmarks of Kirlin Quality / Photometric

More information