INSTALLATION INSTRUCTIONS FOR SENSOR ACTIVATED ETF-600/610 LAVATORY FAUCETS

Size: px
Start display at page:

Download "INSTALLATION INSTRUCTIONS FOR SENSOR ACTIVATED ETF-600/610 LAVATORY FAUCETS"

Transcription

1 ode No Rev. 2 (08/10) INSTLLTION INSTRUTIONS FOR SENSOR TIVTED ETF-600/610 LVTORY FUETS Model ETF V, Sensor ctivated, 4 enterset Lavatory Faucet Model ETF V, Sensor ctivated Pedestal Lavatory Faucet LIMITED WRRNTY Sloan Valve ompany warrants its ETF-600 and ETF-610 Faucets to be made of first class materials, free from defects of material or workmanship under normal use and to perform the service for which they are intended in a thoroughly reliable and efficient manner when properly installed and serviced, for a period of three (3) years (one (1) year for special finishes) from date of purchase. During this period, Sloan Valve ompany will, at its option, repair or replace any part or parts which prove to be thus defective if returned to Sloan Valve ompany, at customer's cost, and this shall be the sole remedy available under this warranty. No claims will be allowed for labor, transportation or other incidental costs. This warranty extends only to persons or organizations who purchase Sloan Valve ompany's products directly from Sloan Valve ompany for purpose of resale. THERE RE NO WRRNTIES WHIH EXTEND EYOND THE DESRIPTION ON THE FE HEREOF. IN NO EVENT IS SLON VLVE OMPNY RESPONSILE FOR NY ONSEQUENTIL DMGES OF NY MESURE WHTSOEVER. PRIOR TO INSTLLTION Prior to installing the Sloan ETF-600 or ETF-610 Faucet, install the items listed below. Refer to Rough-in illustrations on Page 2. When Using Plug-In Transformer Install electrical receptacle for plugin transformer (120 V, 2 amp service for each ETF-233 (24 V, 35 V) plug-in transformer used). When Using ox Mount Transformer Install electrical wiring to transformer location (120 V, 2 amp service for each EL (24 V, 40 V) transformer used). Lavatory/sink Drain line Hot and cold water supply lines or tempered water supply line Multiple Faucets Multiple faucets can be powered by a single transformer, provided that the transformer has been properly sized. llow a minimum of 15 V of current rating for each solenoid valve used. Refer to Step 4 Install Transformer for further information. Mixing Valve When installing the faucet with a Sloan mixing valve, these Installation Instructions ND the Installation Instructions packaged with the mixing valve MUST be followed. K-HEK TEE USGE Important: INSTLL LL ELETRIL WIRING IN ORDNE WITH NTIONL/LOL ODES ND REGULTIONS. INSTLL LL PLUMING IN ORDNE WITH PPLILE ODES ND REGULTIONS. 24 V STEP-DOWN TRNSFORMER MUST E USED. USE PPROPRITE PREUTIONS WHILE ONNETING TRNSFORMER TO 120 V POWER SOURE. DO NOT PLUG TRNSFORMER INTO POWER SOURE (REEPTLE) UNTIL LL WIRING IS OMPLETED. LLOWING 24 V TRNSFORMER WIRES TO TOUH OR SHORT WHILE POWER IS EING SUPPLIED WILL USE PERMNENT DMGE TO THE TRNSFORMER ND IRUIT ONTROL MODULE. KEEP THRED SELNT OUT OF YOUR WTERWY TO PREVENT OMPONENT PRT DMGE! DO NOT USE NY SELNT ON S. FOR THREDED PIPE S, DO NOT PPLY SELNT TO THE FIRST TWO STRTER THREDS. FLUSH LL WTER LINES UNTIL WTER IS LER EFORE ONNETING SOLENOID TO SUPPLY STOPS. DO NOT INSTLL THE SPRY HED UNTIL FTER THE SUPPLY LINES HVE EEN FLUSHED. When connecting the Sloan ETF-600 or ETF-610 Faucet to both hot and cold water supplies, a ak-hek Tee is provided and required as illustrated in the Rough-in drawings on Page 2. Water temperature can be controlled by adjusting the supply stops. When connecting the faucet to a single line water supply or a pre-tempered water supply, a ak-hek Tee is not required. ak-hek Tee is not required or provided when a Temperature Mixing Valve is included with the faucet. TOOLS REQUIRED FOR INSTLLTION Open end wrenches for hex sizes: 1, 5/8, 9/16, 1/2 Slotted screwdriver, 3/16 asin wrench Slotted screwdriver (supplied) Phillips head screwdriver, #2 Pliers Wire stripper/crimping tool

2 FUET ROUGH-IN ETF-600 Faucet with ak-hek Tee for Hot and old Water Supply ETF-600 Faucet with DM and DT Variation Mixing Valves for Hot and old Water Supply ETF-600 Faucet ETF-610 Faucet ETF-610 Faucet with ak-hek Tee for Hot and old Water Supply (shown with 4 trim plate) ETF-610 Faucet with DM Variation Mixing Valve for Hot & old Water Supply (shown with 8 trim plate) ETF-610 Faucet with DM and DT Variation Mixing Valves for Hot and old Water Supply (shown with 4 trim plate) 1 - INSTLL ETF-600 FUET Slide ase Gasket onto Faucet. 1/8 NPT PIPE NIPPLE Insert Faucet Sensor able, Pipe Nipple, and Mounting Studs through the 4 (102 mm) spread deck holes. FUET MOUNTING STUDS SE GSKET SENSOR LE SLOTTED MOUNTING WSHERS (2) WING NUTS (2) 1/8 NPT PIPE TO 3/8 TUE 2 D Secure Faucet to deck using Slotted Mounting Washers and Wing Nuts supplied. pply thread sealant or Teflon tape to threads at end of Faucet Pipe Nipple. Install 1/8" Pipe x 3/8 Tube ompression Fitting on end of Faucet Pipe Nipple. Note: Refer to the Installation Instructions included with the ETF-578- Trim Plate for additional information about using an 8" Trim Plate with an ETF-600 faucet.

3 1 - INSTLL ETF-610 FUET Note: Sloan Valve ompany recommends that this faucet be installed with our trim plate. Our trim plate includes an anti-rotation feature to prevent rotary motion of this single-hole pedestal-style faucet. Slide ase Gasket over Faucet Water Supply Tube and Sensor able. Install optional Trim Plate, then Trim Plate Gasket. Holding Faucet ase Gasket and optional Trim Plate assembly in place, insert Sensor able and Faucet Water Supply Tube through the 1" (25 mm) center hole in deck or lavatory. Use plumber s putty to secure optional Trim Plate. D Thread Sensor able through side of Mounting Spacer. Secure Faucet to deck or lavatory using Flat Washer, Lockwasher and Mounting Nut. FUET 1/4 NPT WTER SUPPLY TUE FLT WSHER LOKWSHER MOUNTING NUT SENSOR LE pply thread sealant or Teflon tape to threads at end of Faucet Water Supply Tube. Install 1/4" Pipe x 3/8 Tube ompression Fitting on end of Faucet Water Supply Tube. SE GSKET MOUNTING SPER 1/4 NPT PIPE TO 3/8 TUE OMPRESSION 2 - INSTLL SOLENOID VLVE Note: Flow direction of Solenoid Valve is indicated by arrow on Valve ody. ETF-600 onnect 3/8 O.D. Supply Tube between ompression Fitting on outlet side of Solenoid Valve and ompression Fitting on Spout s Pipe Nipple or Water Supply Tube. 1/8 PIPE NIPPLE 1/8 PIPE TO 3/8 TUE 3/8 SUPPLY TUE (NOT SUPPLIED) SOLENOID VLVE 3/8 K-HEK OMPRESSION TEE (FOR PPLITIONS USING DUL WTER SUPPLY) ETF-610 1/4 WTER SUPPLY TUE 1/4 PIPE TO 3/8 TUE 3/8 SUPPLY TUE (NOT SUPPLIED) SOLENOID VLVE 3/8 K-HEK OMPRESSION TEE (FOR PPLITIONS USING DUL WTER SUPPLY) 3 - ONNET SUPPLY LINE(S) For Dual Line Hot and old Water Supply pplications Install a 3/8 inch (10 mm) copper supply tube between ak-hek ompression Tee and hot and cold supply stops. (Supply stops and copper supply tube furnished by installer.) Install a 3/8 inch (10 mm) copper supply tube between ak-hek ompression Tee and inlet side of Solenoid Valve. Tighten ompression Fittings securely. Note: Failure to install the ak-hek Tee can result in a cross flow connection when the faucet is off and the supply stops are open. If pressure of the hot and cold water supply differ, hot water can migrate into the cold water supply or vice-versa. Most plumbing codes require that the ak-hek be used to prevent this. K-HEK TEE USED ON DUL WTER SUPPLY PPLITIONS ONLY SOLENOID VLVE SUPPLY TUE OMPRESSION SUPPLY STOP For Single Line Water Supply pplications Install a 3/8 inch (10 mm) copper supply tube between the supply stop and inlet side of Solenoid Valve. (Supply stop and copper supply tube furnished by installer.) Tighten ompression Fittings securely. Important: Flush dirt, debris, and sediment from the supply line(s). SOLENOID VLVE SUPPLY TUE OMPRESSION SUPPLY STOP Important: Keep thread sealant out of your waterway and prevent component part damage! Do not use sealant on compression fittings. When thread sealant is used, do not apply it to the first two starter threads. 3

4 4 - INSTLL TRNSFORMER Multiple Faucets Multiple faucets can be powered by a single transformer that has been properly sized. llow a minimum of 15 V of current rating for each solenoid valve used. Refer to the following example to determine the required current rating for 3 OPTIM faucets. Example: Total number of OPTIM faucets: 3 Total number of solenoid valves: 3 Multiply by current rating: 15 V Minimum current rating of required transformer: 45 V Transformers vailable with the ETF-600 and ETF-610 Faucets Standard Plug-In ETF V 35 V Standard ox Mount EL V 40 V In anada, use ETF-416 (120 V, 35 V). Optional Transformers vailable from Sloan ox Mount EL V 50 V Foot Mount EL V 100 V ox Mount EL V 50 V ll Sloan transformers are 50/60 Hz. Other transformers (not supplied by Sloan) may be used, provided they meet UL requirements for lass 2 transformers. 4 - INSTLL OX MOUNT TRNSFORMER Important: DO NOT supply power to primary side of Transformer until all wiring has been completed. Mount Transformer on a metal electrical junction box (supplied by others). ( J box should be mounted inside chase wall or above ceiling.) Install Transformer within 50 feet (15.24 meters) of Faucet. 18 gauge wire is recommended. Run wires from secondary side of Transformer to 3/8 inch (10 mm) hole at back of ontrol Module Enclosure. If necessary, wires can be run through wall and then inserted through hole in back of ontrol Module Enclosure. 24 V SEONDRY 120 V PRIMRY OX MOUNT TRNSFORMER (EL SHOWN) 4 - INSTLL PLUG-IN TRNFORMER Important: DO NOT plug Transformer into receptacle until all wiring has been completed. The Transformer is supplied with a 10 foot able; however, this able can and should be shortened to meet installation requirements. ONTROL MODULE SE Strip ends of Transformer Power able approximately 3/16 to 1/4 inch (5 to 6 mm). Install Strain Relief 3 inches (76 mm) from one end of Power able. Insert Power able and Strain Relief into hole at back of ontrol Module. Install right angle Strain Relief so that Power able enters the ontrol Module from the bottom. STRIN RELIEF Important: Twist stranded ends of Power able before inserting into Terminal lock. Fraying of Stranded Power able Wire can cause a short and damage the ontrol Module and Transformer when powered. PLUG-IN TRNSFORMER (ETF-233 SHOWN) PLUG-IN TRNSFORMER TRNSFORMER TERMINLS D E onnect Power able to Terminal lock on onnector oard. See Step 6. Install rimp onnectors and connect Power able ends to Transformer Terminals. RIMP ONNETORS POWER LE 4

5 5 - MOUNT ONTROL MODULE TO WLL Install the ontrol Module in an appropriate location as shown in Rough-in. ontrol Module must be installed so that all cables enter from the bottom of the unit. When installed, ables from the Spout and Solenoid Valve to the ontrol Module should have some slack. Mount ontrol Module to wall using Mounting Screws and Plastic nchors. 4 (102 mm) EXTENSION LES Extension ables are available as an option from Sloan to allow for installing the ontrol Module remote from the Faucet Spout and Solenoid Valve. Refer to the Parts List for available lengths. 6 - ONNET ONTROL MODULE ONNETIONS D Route ables from Solenoid Valve and Spout to the ontrol Module. Insert Solenoid Valve onnector into the Modular Receptacle on onnector oard. Insert Locking onnector from Faucet Spout into mating Receptacle on onnector oard. llow 3 to 4 inches (76 to 102 mm) of able to extend into the ontrol Module. Insert each onduit able into a strain relief slot in the ontrol Module. 7 - PLUG IN TRNSFORMER ND STRT-UP ONTROL MODULE ENLOSURE TERMINL LOK - 1. REMOVE TERMINL LOK 2. INSERT POWER LES 3. SEURE WITH SREWS 4. REINSTLL TERMINL LOK STRIN RELIEF SLOTS FROM FUET SPOUT FROM TRNSFORMER RNGE DJ. SREW SEE STEP 8 MODULR REEPTLE ONNETOR ORD POWER LE FROM SOLENOID VLVE Plug Transformer into 120 V Receptacle. Note: The ontrol Module is equipped with two LED lights. When power is supplied by the Transformer, one LED will illuminate green. When Sensor is activated, this LED will change to red. second red LED illuminates when Solenoid Valve is activated. Open Supply Stop(s). With erator removed, activate Faucet for 30 seconds by placing hands in front of Sensor. The Solenoid Valve should click and water should flow from the Spout. If this does not occur, refer to the Troubleshooting section of this instruction instructions. TRNSFORMER lose Supply Stop(s) and install Spray Head in Spout using the Key provided. Reopen Supply Stop(s), activate Faucet and check for leaks. 5

6 8 - RNGE DJUSTMENT The OPTIM ETF-600 and ETF-610 Faucets are factory set to operate when hands are placed 4 to 5 inches (102 to 127 mm) from Sensor. This range should be satisfactory for most installations. If range adjustment is required, refer to the following range adjustment procedures. TO MKE RNGE DJUSTMENT The Range Potentiometer and Dip Switches are located in ontrol Module. Important: Range Potentiometer adjustment screw rotates only 3/4 of a turn; DO NOT over-rotate. Make certain that Dip Switch number 4 is in the UP position. Using the small screwdriver provided, adjust Range Potentiometer clockwise until green (power ON) indicator LED turns red (Faucet is now picking up sink). djust Range Potentiometer back counterclockwise until red LED returns to green. Range is now at maximum. ycle Faucet several times to assure that range as adjusted will not inadvertently pick up IR reflection in lavatory. If IR reflection occurs (green LED will flicker red), adjust Range Potentiometer counterclockwise very slightly and again cycle Faucet. Repeat range adjustment counterclockwise until length of range is at bowl rim of lavatory (plus or minus 1 (25 mm)). Time Out djustment The Faucet Time Out Setting determines the maximum time the Faucet will run upon continuous activation. This timing can be changed to meet individual application requirements. Refer to Table 1 or label on cover of ontrol Module along with the following instructions to set the desired Time Out. The Dip Switches used to set the Time Out are located in the ontrol Module. Set the Time Out by configuring the number 1, 2 and 3 Dip Switches as shown in Table 1. Table 1 Time Out Settings Time Out Dip Switch Setting Switch #1 Switch #2 Switch #3 3 SEONDS UP UP DOWN 6 SEONDS DOWN DOWN UP 12 SEONDS UP DOWN UP 30 SEONDS UP DOWN DOWN 45 SEONDS UP UP UP 1 MINUTE DOWN UP UP 3 MINUTES DOWN DOWN DOWN 20 MINUTES DOWN UP DOWN Unless otherwise specified, all ETF-600/ETF-610 Faucets leave the factory set with a 30 second Time Out. Note: The position of Dip Switch # 4 (range enhancer setting) does not affect Faucet Time Outs. Push ables into slots at the bottom of the ontrol Module. Install ontrol Module over using Screws provided. Refer to illustration in Step 6. TEST FUET OPERTION 1. continuous invisible beam of infrared light is emitted from the OPTIM sensor located at the base of the lavatory faucet. 2. s the user s hands enter the beam s effective range (beneath the spray head), the beam is reflected back into the sensor receiver and activates the solenoid valve. Tempered water flows from the faucet into the sink until the hands are removed from the beam or until the faucet reaches an automatic time out limit setting. 3. When hands are moved away from the sensor, the loss of reflected light initiates an electrical signal that deactivates the solenoid valve, shutting off the water flow. The circuit then automatically resets and is ready for the next user. RE ND LENING OF HROME ND SPEIL FINISHES DO NOT use abrasive or chemical cleaners (including chlorine bleach) to clean faucets that may dull the luster and attack the chrome or special decorative finishes. Use ONLY soap and water, then wipe dry with clean cloth or towel. When cleaning the bathroom tile, protect the faucet from any splattering of cleaner. cids and cleaning fluids will discolor or remove chrome plating. 6

7 TROULESHOOTING GUIDE Note: Remove over from ontrol Module to check diagnostic lights. 1. PROLEM: No water is delivered when Faucet is activated. INDITOR: If no LED lights illuminate: USE: No electricity is being supplied to Faucet. SOLUTION: Ensure that the main power is turned ON. heck all Transformer, Sensor, Solenoid and able onnections. Make sure that Transformer is supplying 24 V (Volts ). If no voltage is detected, replace Transformer. USE: There is an electrical system malfunction. SOLUTION: Reset electrical system. Unplug Sensor onnection. Disconnect power to circuit for ten (10) seconds. Reconnect. INDITOR: If the GREEN LED does NOT illuminate when power is reconnected: USE: There is an electrical system malfunction. SOLUTION: Reset electrical system. Unplug Sensor onnection. Disconnect power to circuit for ten (10) seconds. Reconnect. USE: The ontrol Module circuit is dead. SOLUTION: Replace ETF-450- ontrol Module. INDITOR: If GREEN LED illuminates ND changes to RED when hands are in the Sensor s detection zone ND the RED Solenoid LED illuminates: USE: Water supply stop(s) may be partially closed. SOLUTION: Open supply stop(s) completely. USE: Debris is clogging Solenoid Filter. SOLUTION: Shut off water supply. Remove, clean and reinstall Solenoid Filter. INDITOR: If GREEN LED illuminates ND changes to RED when hands are placed in the Sensor s detection zone ND the RED Solenoid LED flickers with a vibrating/clicking noise heard inside the module: USE: There is a direct short in the Solenoid or Solenoid able. SOLUTION: Replace with ETF-370- Solenoid. INDITOR: If GREEN/RED LED illuminates ND changes to RED when hands are NOT located in the Sensor s detection zone UT the RED Solenoid LED (in upper left corner of circuit) does NOT illuminate: USE: Sensor range is set too long and is detecting the sink. SOLUTION: Reduce Sensor detection range. USE: Sensor is faulty. SOLUTION: Replace Sensor. INDITOR: If GREEN LED illuminates UT does NOT change to RED when hands are placed in the Sensor s detection zone: USE: Sensor range is set too short. SOLUTION: Increase Sensor detection range. USE: Sensor is faulty. SOLUTION: Replace Sensor. 2. PROLEM: Sensing Range is too short. USE: Extended Range Sensitivity is required. SOLUTION: Dip Switch number 4 should be in the DOWN (Extended Range Sensitivity) position. Increase range by adjusting Range Potentiometer clockwise (yellow phillips screw in blue base). 3. PROLEM: Faucet activates by itself (false triggers). USE: Sensor range is set too long. SOLUTION: Decrease range by adjusting Range Potentiometer counterclockwise. If necessary, flip Dip Switch number 4 to the UP (Reduced Range Sensitivity) position. heck surroundings for factors that contribute to Sensor range detection problems (bright lights, highly reflective surfaces, sunlight, etc.). 4. PROLEM: Faucet delivers very low flow or just a dribble. USE: Water supply stop(s) may be partially closed. SOLUTION: Open supply stop(s) completely. USE: Debris is clogging Solenoid Filter. SOLUTION: Shut off water. Remove, clean, and reinstall Solenoid Filter or install Solenoid Valve repair kit ETF USE: Solenoid is worn or faulty. SOLUTION: Rebuild with ETF Solenoid Repair Kit or replace ETF Solenoid. USE: Debris is clogging Faucet erator or Spray Head. SOLUTION:Shut off water. Remove erator or Spray Head (use Key if required). lean and reinstall erator or Spray Head. 5. PROLEM: Faucet does not stop delivering water or continues to drip after user is no longer detected (even after power to the Module has been disconnected). USE: Solenoid Valve is installed backward. SOLUTION: Disconnect Solenoid. Reconnect Solenoid with water flow toward the Faucet (see arrow on Solenoid). USE: Debris is clogging Solenoid. SOLUTION: Remove and clean Solenoid Operator. If necessary, rebuild with ETF Repair Kit. USE: Seat in Solenoid Valve body is damaged or pitted. SOLUTION: Replace with ETF-370- Solenoid. When assistance is required, please contact Sloan Valve ompany Installation Engineering Department at: SLON-14 ( ) 7

8 PRTS LIST 3 ETF ETF Item Part Description No. No. 1 ETF-543- Faucet Spout and Sensor ssembly (ETF-600) 1 ETF-570- Pedestal Faucet Spout and Sensor ssembly (ETF-610) 2 ETF gpm (1.9 Lpm) Spray Head with Key (male thread) ETF gpm (8.3 Lpm) erator Spray Head with Key (male thread) ETF gpm (8.3 Lpm) Laminar Flow Spray Head (male thread) 3 ETF-435 Replacement Key Only for ETF Spray Head and ETF erator Spray Head 4 ETF-546- Faucet Mounting Kit for ETF-600 includes: ase Gasket, two (2) Slotted Mounting Washers, two (2) Wing Nuts, and ETF-547 ompression Fitting onnector 4 EF-123- Faucet Mounting Kit for ETF-610 includes: Spacer, ase Gasket, 1/4 NPSM Hex Nut, Washer, 9/16 Lockwasher, ompression Fitting onnector 5 ETF-547 1/8 NPT Pipe to 3/8 Tube ompression Fitting onnector (ETF-600) 5 EF-129 1/4 NPT Pipe to 3/8 Tube ompression Fitting onnector (ETF-610) 6 ETF-617-3/8 ak-hek Tee ompression Fitting 7 ETF V Solenoid Valve ssembly, includes Wire Harness 8 ETF-437- ssembly Kit, includes: ompression Fittings (2), ompression Nut (1), ompression Sleeve (1) 9 ETF-450- ontrol Module ssembly 10 ETF-233 Plug-In Transformer 11 EL ox Mount Transformer 12 ETF-458- Power able with Strain Relief and rimp onnectors (Transformer to ontrol Module) OPTIONL TRIM PLTES 13 ETF (102 mm) enterset Single-hole Trim Plate Kit for ETF-610 Faucet 13 ETF (203 mm) enterset Single-hole Trim Plate Kit for ETF-610 Faucet MIX (102 mm) enterset Double-hole Trim Plate Kit for ETF-610 Faucet with Optional Mixing Valve MIX (203 mm) enterset Double-hole Trim Plate Kit for ETF-610 Faucet with Optional Mixing Valve ETF (203 mm) enterset Single-hole Trim Plate Kit for ETF-600 Faucet ETF (203 mm) enterset Double-hole Trim Plate Kit for ETF-600 Faucet with Optional Mixing Valve Item Part Description No. No. OPTIONL MIXING VLVES 14 MIX-60- elow Deck Mechanical Water Mixing Valve (DM Variation) 15 MIX-135- elow Deck Thermostatic Water Mixing Valve (DT Variation) 16 MIX-110- Optimix Deck Mounted Water Mixing Valve (DM Variation) (only available for ETF-610 faucet) FUET LE EXTENSION ORDS Faucet to ontrol Module Solenoid to ontrol Module ETF (0.7 meter) Length ETF (0.9 meter) Length ETF (0.9 meter) Length ETF (1.2 meter) Length ETF (1.8 meter) Length ETF (1.8 meter) Length ETF (2.7 meter) Length ETF (2.7 meter) Length SOLENOID VLVE REPIR KIT ETF Includes replacement Filter For additional information about Sloan Mixing Valves or Trim Plates, consult our Installation Instructions and Maintenance Guides. If further assistance is required, please contact the Sloan Valve ompany Installation Engineering Department at: SLON-14 ( ) The information contained in this document is subject to change without notice. SLON VLVE OMPNY Seymour venue Franklin Park, IL Phone: or Fax: or opyright 2010 SLON VLVE OMPNY Rev. 2 (08/10)

9 ode No Rev. 3 (08/10) INSTLLTION INSTRUTIONS FOR TTERY POWERED SENSOR TIVTED LVTORY FUETS EF-615 Pedestal, attery Powered, Sensor ctivated Lavatory Faucet EF enterset, attery Powered, Sensor ctivated Lavatory Faucet LIMITED WRRNTY Sloan Valve ompany warrants its EF-615 and EF-650 Faucets to be made of first class materials, free from defects of material or workmanship under normal use and to perform the service for which they are intended in a thoroughly reliable and efficient manner when properly installed and serviced, for a period of three years (1 year for special finishes) from date of purchase. During this period, Sloan Valve ompany will, at its option, repair or replace any part or parts which prove to be thus defective if returned to Sloan Valve ompany, at customer s cost, and this shall be the sole remedy available under this warranty. No claims will be allowed for labor, transportation or other incidental costs. This warranty extends only to persons or organizations who purchase Sloan Valve ompany s products directly from Sloan Valve ompany for purpose of resale. This warranty does not cover the life of the batteries. THERE RE NO WRRNTIES WHIH EXTEND EYOND THE DESRIPTION ON THE FE HEREOF. IN NO EVENT IS SLON VLVE OMPNY RESPONSILE FOR NY ONSEQUENTIL DMGES OF NY MESURE WHTSOEVER. PRIOR TO INSTLLTION Prior to installing the Sloan EF-615 or EF-650 faucet, install the items listed below. lso, refer to rough-in illustrations on Page 2. Lavatory/sink Drain line Hot and cold water supply lines or tempered water supply line Mixing Valve When installing the faucet with a Sloan Mixing Valve, these Installation Instructions ND the Installation Instructions packaged with the Mixing Valve MUST be followed. Important: LL PLUMING IS TO E INSTLLED IN ORDNE WITH PPLILE ODES ND REGULTIONS. KEEP THRED SELNT OUT OF YOUR WTERWY TO PREVENT OMPONENT PRT DMGE! DO NOT USE NY SELNT ON OMPRESSION S. FOR THREDED PIPE S, DO NOT PPLY SELNT TO THE FIRST TWO STRTER THREDS. FLUSH LL WTER LINES UNTIL WTER IS LER EFORE ONNETING SOLENOID TO SUPPLY STOPS. DO NOT INSTLL THE TTERIES UNTIL THE FUET IS OMPLETELY INSTLLED. If batteries are installed before sensor cable is connected to control module, the faucet will not properly set the sensing range for the sink on which it is installed. TOOLS REQUIRED FOR INSTLLTION Open end wrenches for the following hex sizes: 1/2, 9/16, 5/8, 11/16, 1 asin wrench Phillips head screwdriver, #2 Hammer (if installing plastic or hollow wall anchors to mount the control module) Pliers 1/4" drill bit (if installing plastic wall anchors to mount the control module) 5/16" drill bit (if installing hollow wall anchors to mount the control module) 3/8" drill bit (if installing toggle nut anchors to mount control module) ak-hek Tee Usage When connecting the EF-615 or EF-650 faucet to both hot and cold water supplies, a ak-hek Tee is provided and required as illustrated in Step 3. Water temperature can be controlled by adjusting the supply stops. When connecting the faucet to a single line water supply or a pretempered water supply, a ak-hek Tee is not required. ak-hek Tee is not required or provided when a Temperature Mixing Valve is included with the faucet.

10 FUET ROUGH-IN EF-615 Faucet with ak-hek Tee for Hot and old Water Supply (shown with 4 trim plate) EF-615 Faucet with DM Variation Mixing Valve for Hot and old Water Supply (shown with 8 trim Plate) EF-615 Faucet with DM and DT Variation Mixing Valves for Hot and old Water Supply (shown with 4 trim Plate) DPTER (OPTIONL) DPTER DPTER (OPTIONL) (OPTIONL) (OPTIONL) DPTER (OPTIONL) DPTER (OPTIONL) DPTE (OPTION DPTER (OPTIONL) EF-650 Faucet with ak-hek Tee for Hot and old Water Supply EF-650 Faucet with DM and DT Variation Mixing Valves for Hot and old Water Supply DPTER (OPTIONL) FUET SIDE VIEW DPTER (OPTIONL) DPTER (OPTIONL) DPTER (OPTIONL) DPTER (OPTIONL) EF-615 EF Install Faucet Spout and Optional Trim Plate EF-615 Sloan Valve ompany recommends installation of our trim plate with antirotation feature to prevent rotation of this single-hole pedestal-style faucet. Install Faucet Spout as shown. Use plumber s putty to secure optional Trim Plate, if used. Important: fter installing Mounting Nut, apply thread sealant or Teflon tape to threads of Water Supply Tube. 1/4 NPT WTER SUPPLY TUE PPLY THRED SELNT FTER INSTLLING MOUNTING NUT PPLY PLUMER S PUTTY ROUND EDGE SPER FUET SE GSKET TRIM PLTE (OPTIONL) 2 MOUNTING SPER FLT WSHER LOKWSHER MOUNTING NUT FUET SENSOR LE 1/4 NPT PIPE TO 3/8 TUE

11 1 - Install Faucet Spout EF-650 Refer to the Installation Instructions included with the ETF-578- Trim Plate for additional information about using an 8" Trim Plate with an EF-650 faucet. Install Faucet Spout as shown. Important: pply thread sealant or Teflon tape to threads of Water Supply Pipe Nipple. 1/8 NPT PIPE NIPPLE FUET SE GSKET PPLY THRED SELNT 2 - Install Solenoid Valve Flow direction of Solenoid Valve is indicated by an arrow on Valve ody. Install 3/8 inch (10 mm) supply tube (furnished by installer) between the ompression Fittings on Spout and the top outlet of Solenoid Valve. SLOTTED MOUNTING WSHERS (2) WING NUTS (2) FUET SENSOR LE 1/8 NPT PIPE TO 3/8 TUE Model EF-615 Shown SUPPLY TUE (NOT SUPPLIED) SOLENOID VLVE OMPRESSION (TOP OUTLET) 3 - onnect Supply Line(s) from Supply Stop(s) to Solenoid Valve Inlet Important: Keep thread sealant out of your waterway and prevent component part damage! Do not use sealant on compression fittings. When thread sealant is used, do not apply it to the first two starter threads. Important: Flush dirt, debris, and sediment from the supply line(s). Dual Line Hot and old Water Supply pplications Install a 3/8 inch (10 mm) copper supply tube between ak-hek ompression Tee and hot and cold supply stops. (Supply tubes and stops furnished by installer.) Install a 3/8 inch (10 mm) copper supply tube between ak-hek ompression Tee and inlet side of Solenoid Valve. Tighten ompression Fittings securely. Note: Failure to install the ak-hek Tee can result in a cross flow connection when the faucet is off and the supply stops are open. If pressure of the hot and cold water supply differ, hot water can migrate into the cold water supply or vice-versa. Most plumbing codes require that the ak-hek be used to prevent this. K-HEK TEE USED ON DUL WTER SUPPLY PPLITIONS ONLY SOLENOID VLVE SUPPLY TUE OMPRESSION SUPPLY STOP 3 Single Line Water Supply pplications Install a 3/8 inch (10 mm) copper supply tube between the supply stop and inlet side of Solenoid Valve. (Supply tube and supply stop furnished by installer.) Tighten ompression Fittings securely. SOLENOID VLVE SUPPLY TUE OMPRESSION SUPPLY STOP

12 4 - Mount ontrol Module to Wall Install the ontrol Module in an appropriate location. ontrol Module must be installed so that all cables enter from the bottom of the unit. When installed, ables from the Spout and Solenoid Valve to the ontrol Module should have some slack. 4 (102 mm) Mount ontrol Module to wall using Mounting Screws and Plastic nchors. 5 - ontrol Module onnection Route ables from Solenoid Valve and Spout to the ontrol Module. ONTROL MODULE ENLOSURE Insert Locking onnector from Solenoid Valve into mating Receptacle. Insert onnector from Faucet Spout into Modular Receptacle. POWER LE JK MODULR REEPTLE D E Insert Power able Jack from dapter (optional) into Receptacle. Insert each able into a Strain Relief Slot. 6 - Install atteries LOKING ONNETOR STRIN RELIEF SLOTS FROM DPTER FROM SOLENOID VLVE FROM FUET SPOUT Insert four (4) -size lkaline atteries provided as indicated by the (+) and ( ) symbols inside the attery ompartment. ONTROL MODULE TTERY OMPRTMENT 7 - Plug in dapter (Optional) FOUR (4) -SIZE LKLINE TTERIES Plug dapter into Receptacle. DPTER (OPTIONL) 4

13 8 - Start-Up ctivate ( "dry fire") Faucet by placing hands in front of the Sensor. The Solenoid Valve should click. Once hands are removed the Solenoid Valve should click again. If this does not occur, refer to the Troubleshooting section of this instruction manual. Once "dry firing" segment is complete, remove spray head. Open supply stop(s) then activate Faucet by placing hands in front of the Sensor. The Solenoid Valve should "click" and water should flow from the Spout. ctivate Faucet for 30 seconds by placing hands in front of the Sensor. The Solenoid Valve should click and water should flow from the Spout. If this does not occur, refer to the Troubleshooting section of this instruction manual. lose supply stop(s) and reinstall Spray Head in Spout using the Key provided. Reopen supply stop(s), activate Faucet and check for leaks. 9 - Range djustment The OPTIM Plus EF-615 and EF-650 Faucets are factory set to operate when hands are placed 4 to 5 inches (102 to 127 mm) from Sensor. This range should be satisfactory for most installations. If range adjustment is required, refer to the following range adjustment procedure. The Range Potentiometer is located in the ontrol Module. ONTROL MODULE Important: Range Potentiometer adjustment screw rotates only 3/4 of a turn; DO NOT over-rotate. Over-rotating will damage range adjustment screw. ycle Faucet several times to assure that the Sensor will not inadvertently pick up reflection off the edge of the sink. If reflection occurs, adjust Range Potentiometer counterclockwise very slightly and again cycle Faucet. Repeat adjustment procedure until desired range is achieved. SREWDRIVER IS PROVIDED ON THE INSIDE OVER OF THE ONTROL MODULE FOR MKING RNGE DJUSTMENTS 10 - Noise Reduction (NR) and Time Out (Mode) Jumper Settings For jumper settings, refer to Table below or label on cover of ontrol Module along with the instructions in this Step. Noise Reduction (NR) Setting When operating the faucet on batteries alone, set the NR jumper to bridge pins 1 and 2. When operating the faucet using the plug-in adapter with battery backup, bridge pins 2 and 3. Time Out (Mode) Setting The Faucet Time Out Setting determines the maximum time the Faucet will run upon continuous activation. This timing can be changed to meet individual application requirements. Unless otherwise specified, Faucets leave the factory set with a 30 second Time Out. RNGE POTENTIOMETER DESRIPTION NOISE REDUTION (NR) SETTING Normal Operation (dapter w/attery ackup Operation) NR Enabled (attery Operation Only) TIME OUT (MODE) SETTING Second On Demand 30 Second On Demand PINS TIME OUT (MODE) JUMPER NOISE REDUTION (NR) JUMPER

14 11 - Install over onto ontrol Module Install over over the ontrol Module making sure that all four (4) locking tabs snap into place. Secure using the two (2) screws provided. over can be installed in only one orientation. ONTROL MODULE ONTROL MODULE OVER OVER SREW (2) LOKING T (4) Operation 1. continuous invisible beam of infrared light is emitted from the sensor located on the throat of the lavatory faucet. are and leaning DO NOT USE abrasive or chemical cleaners (including chlorine bleach) to clean faucets as they may dull the luster and attack the chrome or special decorative finishes. Use ONLY soap and water, then wipe dry with clean cloth or towel. While cleaning the bathroom tile, the faucet should be protected from any splattering of cleaner. cids and cleaning fluids will discolor or remove chrome plating. 2. s the user s hands enter the beam s effective range (beneath the spray head), the beam is reflected back into the sensor receiver and activates the solenoid valve. Tempered water flows from the faucet into the sink until the hands are removed from the beam or until the faucet reaches an automatic time out limit setting. 3 When hands are moved away from the sensor, the loss of reflected light initiates an electrical signal that deactivates the solenoid valve, shutting off the water flow. The circuit then automatically resets and is ready for the next user. attery Replacement Procedure (Water does not need to be turned off) The Sloan Optima Plus EF-615 and EF-650 faucets are furnished with four (4) -size alkaline batteries that provide up to two (2) years of operation (8000 cycles per month). flashing LED signal indicates that battery power will be depleted within one (1) month. Remove over as follows: 1. Remove the two (2) over Screws. 2. Press in the middle of both sides. 3. Pull over straight out from ontrol Module ase Remove old batteries and insert four (4) new -size lkaline atteries as indicated by the (+) and ( ) symbols inside the attery ompartment. Reinstall over. Refer to Step

15 Solenoid Screen Filter leaning Procedure Turn off water supply at supply stop(s). ctivate Faucet to relieve system pressure. E Reinstall Water supply Line to Inlet Side of Solenoid Valve. Remove Water Supply Line from Inlet Side of Solenoid Valve. Remove ap, Water Line Fitting, Gasket, Filter Housing and Filter from Solenoid Valve Housing. Slide Filter off Filter Housing. lean Filter using fresh tap water only. If necessary, use a small brush to clean. Use caution while cleaning to prevent damage to Filter. If any Filter components are damaged, replace as necessary. Examine the Gasket for wear or damage; replace if necessary. INLET SIDE OF SOLENOID VLVE HOUSING FILTER FILTER HOUSING WTER LINE GSKET P D Reinstall Filter on Filter Housing. Install Filter Housing, Gasket, Water Line Fitting and ap onto Solenoid Valve Housing. Tighten ap securely. Troubleshooting Guide 1. PROLEM: Sensor LED does not function (indicator light on sensor window in faucet spout does not flash during initial 10 minute set-up mode). USE: There is no visible indicator light. Normal operation. SOLUTION: This is a normal operating feature of the faucet. 2. PROLEM: Faucet does not deliver any water when Sensor is activated. INDITOR: Solenoid valve produces audible LIK. USE: Water supply stop(s) closed. SOLUTION: Open supply stop(s) completely. INDITOR: Solenoid valve DOES NOT produce an audible LIK. USE: Solenoid Lead is not properly connected to the ontrol Module. SOLUTION: Disconnect and reconnect Solenoid Lead to the ontrol Module. USE: No battery or Transformer (optional) power is being supplied to Sensor. SOLUTION: Ensure that the batteries are installed properly. heck that the orientation of each battery matches the positive (+) and negative ( ) symbols shown on the bottom of the battery compartment. Reinsert the atteries into the ontrol Module. Transformer (optional) is unplugged or wall receptacle has no power. USE: Sensor able is not properly connected to the ontrol Module. SOLUTION: Disconnect and reconnect Sensor able to the ontrol Module. USE: Sensor range is set at minimum distance. SOLUTION: Increase Sensor range. Refer to Step 9, Range djustment. USE: ontrol Module assembly is defective. SOLUTION: Replace ontrol Module assembly. ONTROL MODULE ENLOSURE POWER LE JK LOKING ONNETOR STRIN RELIEF SLOTS FROM OPTIONL DPTER FROM SOLENOID VLVE MODULR REEPTLE FROM FUET SPOUT 3. PROLEM: Faucet delivers only a slow flow or dribble when Sensor is activated. USE: Water supply stop(s) partially closed. SOLUTION: Open supply stop(s) completely. USE: Solenoid Filter is clogged. SOLUTION: Remove, clean and reinstall Filter. Refer to Solenoid Screen Filter leaning Procedure on Page 6. Replace with new Solenoid Filter Kit if necessary. USE: erator is clogged. SOLUTION: Remove, clean and reinstall erator. 4. PROLEM: Faucet does not stop delivering water or continues to drip after user is no longer detected (automatic shut-off fails even when batteries are removed). USE: Solenoid Valve has been connected backwards. SOLUTION: Disconnect Solenoid Valve compression fittings at both the inlet and outlet positions. The water should flow from inlet through the Solenoid Valve to the outlet according to the direction of the arrow shown on the side of the Solenoid Valve. Reconnect the compression fittings in the correct orientation. USE: Solenoid Valve is dirty. SOLUTION: ackflush by reversing water flow (opposite to the direction shown by the arrow on the side of the Solenoid Valve) through the Solenoid Valve. Reconnect the compression fittings in the correct orientation. ctivate faucet. USE: Solenoid Valve Module is defective. SOLUTION: Replace Solenoid Valve Module. 5. PROLEM: The water temperature is too hot or too cold on a faucet connected to hot and cold supply lines with ak-hek Tee. USE: Supply stops are not adjusted properly. SOLUTION: djust supply stops. NOTE: For some systems, a Thermostatic Mixing Valve may be required. 6. PROLEM: The Red LED turns on in the control module (below deck). USE: One (or more) of the batteries is dead. SOLUTION: To ensure proper operation, insert four (4) new -size lkaline batteries. heck that the orientation of each battery matches the positive (+) and negative ( ) symbols shown on the bottom of the battery compartment. Reinsert atteries into the ontrol Module. When assistance is required, please contact your local Sloan Representative or Sloan Valve ompany Installation Engineering Department at: SLON-14 ( ) 7

16 PRTS LIST 3 EF EF HOT OLD Item Part Description No. No. 1 ETF-755- P Faucet ssembly 4 enterset (ETF-650) 1 EF-120- Pedestal Faucet Spout and Sensor ssembly (EF-615) ETF-749- Sensor Only 2 ETF gpm (1.9 Lpm) Spray Head with Key (male thread) ETF gpm (8.3 Lpm) erator Spray Head with Key (male thread) F-174 P Spray Head 0.5 gpm Laminar Flow Spray Head (male thread) 3 ETF-435 Replacement Key Only for ETF gpm (1.9 Lpm) Spray Head and ETF gpm (8.3 Lpm) erator Spray Head (NOT required for F-175-L 2.2 gpm/8.3 Lpm Laminar Flow Spray Head) 4 ETF-546- Faucet Mounting Kit for EF-650 includes ase Gasket, two (2) Slotted Mounting Washers, two (2) Wing Nuts and ETF-547 ompression Fitting onnector 4 EF-123- Faucet Mounting Kit for EF-615 includes ase Gasket, Spacer, Washer, 9/16 Lockwasher, 1/4 NPSM Hex Nut and ETF-547 ompression Fitting onnector 5 ETF-547 1/8 NPT Pipe to 3/8 Tube ompression Fitting onnector (female) 6 ETF-617-3/8 ak-hek Tee ompression Fitting 7 ETF VD Solenoid ssembly 8 ETF-735- ontrol Module ETF-736 ontrol Module Replacement Gasket (two required) Item Part Description No. No. 9 SFP V/6 VD Plug-in dapter (optional) 10 ETF-443- Hardwired Mounting Kit (optional) EF-113 ompression Fitting Kit (optional) includes: ETF compression nuts ETF ferrules ETF-91 1 plastic screwdriver OPTIONL TRIM PLTES 11 ETF-607-4" (102 mm) enterset Single-hole Trim Plate Kit for EF-615 Faucet (Faucet only) 11 ETF-608-8" (204 mm) enterset Single-hole Trim Plate Kit for EF-615 Faucet (Faucet only) OPTIONL MIXING VLVES 12 MIX-60- elow Deck Mechanical Water Mixing Valve (DM Variation) 13 MIX-135- elow Deck Thermostatic Water Mixing Valve (DT Variation) 14 MIX-110- Optimix Deck Mounted Water Mixing Valve (only available for EF-615 faucets) For additional information about Sloan Mixing Valves or Trim Plates, consult our Installation Instructions and Maintenance Guides. The information contained in this document is subject to change without notice. SLON VLVE OMPNY SEYMOUR VENUE FRNKLIN PRK, IL Phone: VLVE-9 or Fax: or opyright 2010 SLON VLVE OMPNY Rev. 3 (08/10)

17 O P T I M F U E T S ode No: rev. 3 (12/10) INSTLLTION INSTRUTIONS FOR EF-625/EF-655 SENSOR TIVTED FUETS MODELS EF-625 EF-655 attery powered, Sensor activated lavatory Faucets EF-625 EF-655 installation of the Sloan optima plus EF-625 or EF-655 attery powered, Sensor activated Faucet makes wash-up totally hands free providing the ultimate in sanitary protection and automatic operation. The optima plus faucet uses infrared technology to sense the user s presence and turn on a water supply that has been pre-mixed to the desired water temperature. when the user s hands are removed from the invisible beam of light, the water supply automatically turns off. in addition, the faucet is powered by four (4) batteries which eliminates the need to run any electrical lines to the system. The Sloan EF-625 or EF-655 battery powered, sensor activated faucet comes complete with an integral faucet and sensor assembly, control module, alkaline batteries, and all mounting hardware. ak-cheks and a grid strainer are also available as optional equipment. The installer should supply 3/8 copper supply tube or flexible hose connections. The following instructions serve as a guide when installing the Sloan EF-625 or EF-655 faucet. as always, good safety practices and care when installing your new faucet. if further assistance is required, contact your nearest Sloan representative office or the Sloan installation Engineering Department at SloaN-14. LIMITED WRRNTY Sloan Valve ompany warrants its EF-625 and EF-655 faucets to be made of first class materials, free from defects of material or workmanship under normal use and to perform the service for which they are intended in a thoroughly reliable and efficient manner when properly installed and serviced, for a period of three (3) years (one (1) year for special finishes) from date of purchase. During this period, Sloan Valve ompany will, at its option, repair or replace any part or parts which prove to be thus defective if returned to Sloan Valve ompany, at customer s cost, and this shall be the sole remedy available under this warranty. No claims will be allowed for labor, transportation or other incidental costs. This warranty extends only to persons or organizations who purchase Sloan Valve ompany s products directly from Sloan Valve ompany for purpose of resale. This warranty does not cover the life of batteries. ThErE are No warranties whih ExTEND EyoND ThE DESripTioN on ThE FaE hereof. in No EVENT is SloaN ValVE ompany responsile For any onsequential DamagES of any measure whatsoever.

18 ROUGH-INS EF-625 FUET WITH DUL LINE WTER SUPPLY EF-625 FUET WITH SINGLE LINE WTER SUPPLY SPOUT SE GSKET SPOUT SE GSKET SPER, FLT WSHER, LOK WSHER ND NUT SPER, FLT WSHER, LOK WSHER ND NUT WING NUT ND SLOTTED WSHER 1/4" NPT PIPE TO 3/8" TUE ONTROL MODULE 1/4" NPT PIPETO3/8" TUE ONTROL MODULE 3/8" OPPER SUPPLY TUE (NOT SUPPLIED) 3/8" OPPER SUPPLY TUE (NOT SUPPLIED) 3/8" 3/8" SOLENOID VLVE SOLENOIDVLVE 3/8" OMPRESSION 3/8" OMPRESSION 3/8" OPPER SUPPLY TUES (NOT SUPPLIED) 3/8" OMPRESSION TEE K HEK 3/8" OPPER SUPPLY TUE (NOT SUPPLIED) 3/8" OPPER SUPPLY TUE (NOT SUPPLIED) 3/8" OMPRESSION STOP OR MIXING VLVE (NOT SUPPLIED) 3/8" OMPRESSION STOPS (NOT SUPPLIED) EF-655 FUETWITHDUL LINE WTER SUPPLY EF-655FUETWITHSINGLE LINE WTER SUPPLY SPOUT SE GSKET SPOUT SE GSKET 1/8" PIPE NIPPLE WING NUT ND SLOTTEDWSHER 1/8" PIPE NIPPLE WING NUT ND SLOTTED WSHER 1/8" NPT PIPE TO 3/8" TUE 3/8" OPPER SUPPLY TUE (NOT SUPPLIED) ONTROL MODULE 1/8" NPT PIPETO3/8" TUE 3/8" OPPER SUPPLY TUE (NOT SUPPLIED) ONTROL MODULE 3/8" 3/8" SOLENOID VLVE SOLENOIDVLVE 3/8" OMPRESSION 3/8" OMPRESSION 3/8" OPPER SUPPLY TUES (NOT SUPPLIED) 3/8" OMPRESSION TEE K HEK 3/8" OPPER SUPPLY TUE (NOT SUPPLIED) 3/8" OPPER SUPPLY TUE (NOT SUPPLIED) 3/8" OMPRESSION STOP OR MIXING VLVE (NOT SUPPLIED) 3/8" OMPRESSION STOPS (NOT SUPPLIED) 1" (25 mm) minimumdiameter hole required to mount faucet shank on deck. 3/8" (10 mm)minimumdiameter clearance for mounting studs.

19 ROUGH-INS (ONTINUED) EF-625 FUETWITHOTH DUL ND SINGLE LINE WTER SUPPLIES EF-655 FUETWITHOTH DUL ND SINGLE LINE WTER SUPPLIES 2" (51mm) 1-1/4" (32 mm) 4-1/2" (114 mm) 12 o 2-1/2" (64 mm) 3-1/2" (89 mm) 2" (51 mm) 1-1/4" (32 mm) 4-1/2" (114 mm) 12 o 2-1/2" (64 mm) 3-1/2" (89 mm) 3/4" (19 mm) 3/4" (19 mm) TOTL LENGTH OF SENSOR LE IS 24" (610 mm) 2-3/4" (70 mm) 3-1/2" (89 mm) TOTL LENGTH OF SENSOR LE IS 23" (584 mm) 2-3/4" (70 mm) 3-1/2" (89 mm) 5-1/4" (133 mm) 5-1/4" (133 mm) PRIOR TO INSTLLTION prior to installing the Sloan EF-625 or EF-655 faucet, install the items listed below. lavatory/sink Drain line hot water and old water or Tempered water Supply lines important: all pluming is To E insstalled in aordane with appliale odes and regulations FluSh all water lines prior To making onnetions mixing ValVE when installation includes one of Sloan s mixing Valve, these instructions and those included with the mixing valve must be followed. The Sloan EF-625 and EF-655 battery powered sensor activated faucets can be supplied with two ak-heks. when connecting the faucet to a hot and cold water supply, two ak-heks are required. water temperature can be controlled by adjusting the supply stops. when connecting the faucet to a single line water supply or a pre-tempered water supply, a ak-hek is not required. 1 - INSTLL K-HEK TEE (OPTIONL) The Sloan ak-hek is designed for installation on a 3/8 supply stop. if an existing stop is used, the stop may require replacement or additional fittings not supplied by Sloan for connection of the ak-hek to the hot and cold water supply lines. Supply stops should be furnished by the installer. SUPPLY TUE after flushing the water supply lines through the stops, use a compression nut and compression sleeve to connect inlet end of ak-hek to the Supply Stop. K-HEK TEE NoTE: Failure to install the ak-hek can result in a cross flow connection when the faucet is in the off position and the supply stops are open. if the pressures of the hot water supply and the cold water supply are different, hot water can migrate into the cold water supply or cold water can migrate into the hot water supply. most plumbing codes require that the ak-hek be used to prevent this occurance.

20 2 - INSTLL EF-625 FUET D NoTE: Sloan Valve ompany reccomends that this faucet is installed with our trim plate. our trim plate includes an anti-rotation feature to prevent rotary motion of this single-hole pedestal-style faucet. Slide faucet base gasket over faucet shank and sensor cable. install optional trim plate next followed by the trim plate gasket. holding the faucet base gasket and optional trim plate assembly in place, insert sensor cable and faucet shank through the 1 (25 mm) center hole in deck lavatory. use plumber s putty to secure optional trim plate. Thread sensor cable through side of mounting spacer, and then secure faucet to deck or lavatory using the mounting washer, lock washer and nut. apply thread sealant or Teflon tape to threads at end of faucet shank. install 3/8 compression fitting on end of faucet shank. 2 - INSTLL EF-655 FUET 1/4" NPT PIPE NIPPLE MOUNTING SPER FLT WSHER LOKWSHER MOUNTING NUT SE GSKET FUETSENSOR LE 1/4" NPT PIPETO3/8" TUE OMPRESSION FUET NoTE: refer to the installation instructions included with the ETF-578-a trim plate for addtional information about using an 8 trim plate with an EF-655 faucet. FUET MOUNTING STUDS Slide faucet base gasket onto faucet. 1/8" NPTPIPE NIPPLE insert faucet sensor cable, pipe nipple, and mounting studs through the 4 (102 mm) spread deck holes. Secure faucet to deck using slotted mounting washers and wing nuts supplied. SE GSKET FUET SENSOR LE SLOTTED MOUNTING WSHERS(2) WINGNUTS (2) 3 - MOUNT ONTROL MODULE TO WLL important: Do NoT install control module upside down. The control module may be oriented so that it faces sideways (vertically); however, optimum performance is obtained when the control module is horizontal with the Sloan logo on the cover facing up. 3-1/2" (89mm) WLL PLSTI NHOR WITH SREW ND WSHER SHOWN install the control module in an appropriate location. all four (4) cover screws must be accessible from the chosen mounting position. after installation, the cable from spout to control module should have some slack. 4-3/8" (111 mm) remove control module cover from control module base. use the control module base as a template to mark locations on wall for mounting fasteners. Determine the appropriate mounting fastener for the particular wall type (three different fastener types are included; see parts list). Drill four (4) appropriately sized holes. For plastic wall anchor 1/4 (6 mm) holes For hollow wall anchor 5/16 (8 mm) holes For toggle nut anchor holes attach ontrol module base to wall using appropriate fastener. DRILL FOUR HOLESINTOWLL USING MOUNTING FSTENERS PPROPRITE FOR THE PRTIULR WLL TYPE: PLSTI WLL NHOR 1/4" (6 mm) HOLE HOLLOWWLL NHOR 5/16" (8 mm) HOLE TOGGLE NUT NHOR 3/8" (10 mm) HOLE ONTROL MODULE

INSTALLATION INSTRUCTIONS FOR SENSOR ACTIVATED LAVATORY FAUCETS

INSTALLATION INSTRUCTIONS FOR SENSOR ACTIVATED LAVATORY FAUCETS ode No. 0816318 Rev. 1a (11/08) INSTLLTION INSTRUTIONS FOR SENSOR TIVTED LVTORY FUETS Model ETF-600 24 V, Sensor ctivated, 4 enterset Lavatory Faucet Model ETF-610 24 V, Sensor ctivated Pedestal Lavatory

More information

INSTALLATION INSTRUCTIONS FOR SENSOR ACTIVATED ETF-600/610 LAVATORY FAUCETS

INSTALLATION INSTRUCTIONS FOR SENSOR ACTIVATED ETF-600/610 LAVATORY FAUCETS ode No. 0816318 Rev. 2 (08/10) INSTLLTION INSTRUTIONS FOR SENSOR TIVTED ETF-600/610 LVTORY FUETS Model ETF-600 24 V, Sensor ctivated, 4 enterset Lavatory Faucet Model ETF-610 24 V, Sensor ctivated Pedestal

More information

INSTALLATION INSTRUCTIONS FOR BATTERY POWERED SENSOR ACTIVATED LAVATORY FAUCETS

INSTALLATION INSTRUCTIONS FOR BATTERY POWERED SENSOR ACTIVATED LAVATORY FAUCETS Code No. 081631 Rev. 3 (08/10) INSTLLTION INSTRUCTIONS FOR TTERY POWERED SENSOR CTIVTED LVTORY FUCETS EF-615 Pedestal, attery Powered, Sensor ctivated Lavatory Faucet EF-650 4 Centerset, attery Powered,

More information

ETF-600 Sensor Operated Lavatory Faucet

ETF-600 Sensor Operated Lavatory Faucet INSTALLATION INSTRUCTIONS OPTIMA SYSTEMS SENSOR OPERATED LAVATORY FAUCET ETF-600 I.I. Code No. 0816318 ETF-600 Sensor Operated Lavatory Faucet Includes Instructions for Installation of Optional Back Checks

More information

INSTALLATION INSTRUCTIONS FOR BATTERY POWERED SENSOR ACTIVATED HAND WASHING FAUCETS

INSTALLATION INSTRUCTIONS FOR BATTERY POWERED SENSOR ACTIVATED HAND WASHING FAUCETS ode No. 081633 Rev. 1 (1/08) INSTLLTION INSTRUTIONS FOR TTERY POWERED SENSOR TIVTED HND WSHING FUETS Model EF-550-S-H Wall Mounted, attery Powered, Sensor ctivated, Gooseneck Hand Washing Faucet With Surgical

More information

INSTALLATION INSTRUCTIONS FOR BATTERY POWERED SENSOR ACTIVATED HAND WASHING FAUCETS

INSTALLATION INSTRUCTIONS FOR BATTERY POWERED SENSOR ACTIVATED HAND WASHING FAUCETS ode No. 081633 Rev. (08/10) INSTLLTION INSTRUTIONS FOR TTERY POWERED SENSOR TIVTED HND WSHING FUETS Model EF-550-S-H Wall Mounted, attery Powered, Sensor ctivated, Gooseneck Hand Washing Faucet With Surgical

More information

EBF-750 Deck-Mounted Battery Powered Sensor Operated Gooseneck Faucets

EBF-750 Deck-Mounted Battery Powered Sensor Operated Gooseneck Faucets INSTALLATION INSTRUCTIONS BATTERY POWERED SENSOR OPERATED HAND WASHING FAUCETS EBF-750 I.I. Code No. 0816324 EBF-750 Deck-Mounted Battery Powered Sensor Operated Gooseneck Faucets Includes Instructions

More information

INSTALLATION INSTRUCTIONS FOR ELECTRONIC SENSOR ACTIVATED LAVATORY FAUCETS

INSTALLATION INSTRUCTIONS FOR ELECTRONIC SENSOR ACTIVATED LAVATORY FAUCETS (Models shown with ISM Integral Spout Mixer) INSTLLTION INSTRUTIONS FOR ELETRONI SENSOR TIVTED LVTORY FUETS EF-275 Series Solar Powered with attery ackup Sensor ctivated Lavatory Faucets EF-250 Series

More information

INSTALLATION INSTRUCTIONS FOR SLOAN SF ELECTRONIC SENSOR ACTIVATED LAVATORY FAUCETS

INSTALLATION INSTRUCTIONS FOR SLOAN SF ELECTRONIC SENSOR ACTIVATED LAVATORY FAUCETS Code No. 0816496 Rev. 2 (02/09) INSTLLTION INSTRUCTIONS FOR SLON SF ELECTRONIC SENSOR CTIVTED LVTORY FUCETS SF SERIES FUCETS SF-2100 Series Transformer Powered with attery ackup, Sensor ctivated, Pedestal

More information

INSTALLATION INSTRUCTIONS FOR EAF-350 SERIES ELECTRONIC, BATTERY-POWERED, SENSOR-ACTIVATED LAVATORY FAUCETS

INSTALLATION INSTRUCTIONS FOR EAF-350 SERIES ELECTRONIC, BATTERY-POWERED, SENSOR-ACTIVATED LAVATORY FAUCETS ode No: 0816654 Rev. 3 (04/15) INSTLLTION INSTRUTIONS FOR EF-350 SERIES ELETRONI, TTERY-POWERED, SENSOR-TIVTED LVTORY FUETS Faucet Variations -ISM Integral Spout Temperature Mixer Limited Warranty Unless

More information

INSTALLATION INSTRUCTIONS FOR ELECTRONIC, BATTERY-POWERED, SENSOR-ACTIVATED LAVATORY FAUCETS

INSTALLATION INSTRUCTIONS FOR ELECTRONIC, BATTERY-POWERED, SENSOR-ACTIVATED LAVATORY FAUCETS ode No: 0816654 Rev. 2 (04/15) INSTLLTION INSTRUTIONS FOR ELETRONI, TTERY-POWERED, SENSOR-TIVTED LVTORY FUETS Faucet Variations -ISM Integral Spout Temperature Mixer Limited Warranty Unless otherwise noted,

More information

Optima ETF-600/ETF-610

Optima ETF-600/ETF-610 Optima ETF-600/ETF-610 4B ETF-610 1C 4A 5 6 7 7 6 ETF-600 1A 1C PARTS LIST ETF-600 AND ETF-610 FAUCETS Item No. Code No. Part No. Description 1A. 065086 ETF-54-A Faucet and Sensor Assembly (ETF-600). 065117

More information

INSTALLATION INSTRUCTIONS SINGLE, DOUBLE, TRIPLE AND QUADRUPLE STATION SENSOR OPERATED SOLID SURFACE AND BIO-DECK LAVATORY SYSTEMS ELC-41000

INSTALLATION INSTRUCTIONS SINGLE, DOUBLE, TRIPLE AND QUADRUPLE STATION SENSOR OPERATED SOLID SURFACE AND BIO-DECK LAVATORY SYSTEMS ELC-41000 Code No. 08657 Rev. (/0) INSTLLTION INSTRUCTIONS SINGLE, DOULE, TRIPLE ND QUDRUPLE STTION SENSOR OPERTED SOLID SURFCE ND IO-DECK LVTORY SYSTEMS ELC-000 Single Station Sensor Operated Solid Surface Lavatory

More information

INSTALLATION INSTRUCTIONS FOR SENSOR ACTIVATED LAVATORY FAUCETS

INSTALLATION INSTRUCTIONS FOR SENSOR ACTIVATED LAVATORY FAUCETS ode No. 0816302 Rev. 3b (11/08) INSTLLTION INSTRUTIONS FOR SENSOR TIVTE LVTORY FUETS Model EF-187 attery Powered, Sensor ctivated Lavatory Faucet Furnished with a hrome Plated Metal Throat Plate Model

More information

INSTALLATION INSTRUCTIONS FOR ELECTRONIC SENSOR ACTIVATED LAVATORY FAUCETS

INSTALLATION INSTRUCTIONS FOR ELECTRONIC SENSOR ACTIVATED LAVATORY FAUCETS Code No. 0816490 Rev. 4 (12/10) (Models shown with ISM Integral Spout Mixer) EF-275 Series Solar Powered with attery ackup Sensor ctivated Lavatory Faucets INSTLLTION INSTRUCTIONS FOR ELECTRONIC SENSOR

More information

Optima ETF-500. Hand Hygiene. Repair Parts and Maintenance Guide PARTS LIST ETF-500 FAUCET ETF-500. See page 157 for faucet cable extension cords.

Optima ETF-500. Hand Hygiene. Repair Parts and Maintenance Guide PARTS LIST ETF-500 FAUCET ETF-500. See page 157 for faucet cable extension cords. Optima ETF-500 ETF-500 TO MOUNT FAUCET ON A SURFACE BETWEEN 0.1 (10 MM) AND 1.00 (25 MM) THICK, USE THE HARDWARE SHOWN BELOW. 7 1B 3B 1A 2 3A 5 6 11 10 5 9 PARTS LIST ETF-500 FAUCET Item No. Code No. Part

More information

INSTALLATION INSTRUCTIONS FOR ELECTRONIC SENSOR-ACTIVATED LAVATORY FAUCETS

INSTALLATION INSTRUCTIONS FOR ELECTRONIC SENSOR-ACTIVATED LAVATORY FAUCETS Code No. 086490 Rev. 6 (05/6) (Models shown with ISM Integral Spout Mixer) EF-275 Series Solar Powered with attery ackup Sensor ctivated Lavatory Faucets INSTLLTION INSTRUCTIONS FOR ELECTRONIC SENSOR-CTIVTED

More information

BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC ACTIVE IR LAVATORY FAUCETS

BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC ACTIVE IR LAVATORY FAUCETS SYS INSTLLTION INSTRUTIONS FOR ELETRONI TIVE IR LVTORY FUETS EFX-3XX Pedestal, Sensor ctivated Lavatory Faucets ny pplication. ny Environment. ode No: 0816640 Rev. 6 (09/14) EFX-6XX Integrated ase, Sensor

More information

Battery Powered Sensor Operated Lavatory Faucets. Plug-in Transformer Powered Sensor Operated Lavatory Faucets PARTS LIST

Battery Powered Sensor Operated Lavatory Faucets. Plug-in Transformer Powered Sensor Operated Lavatory Faucets PARTS LIST 1A 1B 8 EAF-100/150 I.I. Rev. 0a (11/02) Code No. 0816542 INSTALLATION INSTRUCTIONS ELECTRONIC, SENSOR OPERATED LAVATORY FAUCETS EAF-150 Series Battery Powered Sensor Operated Lavatory Faucets 2 3 7 10

More information

INSTALLATION INSTRUCTIONS FOR DOUBLE AND TRIPLE STATION SENSOR ACTIVATED SOLID SURFACE LAVATORY SYSTEMS

INSTALLATION INSTRUCTIONS FOR DOUBLE AND TRIPLE STATION SENSOR ACTIVATED SOLID SURFACE LAVATORY SYSTEMS ode No. 0816836 Rev. 0 (07/09) INSTLLTION INSTRUTIONS FOR DOULE ND TRIPLE STTION SENSOR TIVTED SOLID SURFE LVTORY SYSTEMS EW-62000 EW-62050 Double Station Sensor ctivated Solid Surface Lavatory System

More information

BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC CAPACITANCE SENSING LAVATORY FAUCETS EFX-3XX Pedestal, Sensor Activated Lavatory Faucets

BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC CAPACITANCE SENSING LAVATORY FAUCETS EFX-3XX Pedestal, Sensor Activated Lavatory Faucets BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC CAPACITANCE SENSING LAVATORY FAUCETS EFX-3XX Pedestal, Sensor Activated Lavatory Faucets Any Application. Any Environment. Code No. 0816407 Rev. 5 (05/16)

More information

INSTALLATION INSTRUCTIONS FOR PISTON TYPE FLUSHOMETER EXPOSED CLOSET AND URINAL INSTALLATIONS

INSTALLATION INSTRUCTIONS FOR PISTON TYPE FLUSHOMETER EXPOSED CLOSET AND URINAL INSTALLATIONS ode No. 0816477 Rev. 0 (04/07) Flushometers INSTLLTION INSTRUTIONS FOR PISTON TYPE FLUSHOMETER EXPOSED LOSET ND URINL INSTLLTIONS loset Flushometer for 1½" Top Spud rown II & rown 111 rown II & rown 115

More information

BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC INFRARED SENSOR ACTIVATED LAVATORY FAUCETS. Below Deck, Mechanical Below Deck, Thermostatic

BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC INFRARED SENSOR ACTIVATED LAVATORY FAUCETS. Below Deck, Mechanical Below Deck, Thermostatic SYS ny pplication. ny Environment. INSTLLTION INSTRUTIONS FOR ELETRONI INFRRE SENSOR TIVTE LVTORY FUETS ode No. 0816408 Rev. 7 (09/14) EFX-150.500.0000 Model Shown (High Model with owed rown and Water

More information

INSTALLATION INSTRUCTIONS FOR SLIMLINE BEDPAN WASHER WITH EXPOSED ROYAL AND REGAL XL FLUSHOMETER

INSTALLATION INSTRUCTIONS FOR SLIMLINE BEDPAN WASHER WITH EXPOSED ROYAL AND REGAL XL FLUSHOMETER ode No. 0816191 Rev. 2 (05/10) INSTLLTION INSTRUTIONS FOR SLIMLINE EDPN WSHER WITH EXPOSED ROYL ND REGL XL FLUSHOMETER Slimline edpan Washers Royal PW-1000 Standard Royal PW-1005 With Deoseptic Unit Royal

More information

INSTALLATION INSTRUCTIONS FOR OPTIMA SYSTEMS SENSOR ACTIVATED ROYAL CONCEALED and EXPOSED URINAL FLUSHOMETERS

INSTALLATION INSTRUCTIONS FOR OPTIMA SYSTEMS SENSOR ACTIVATED ROYAL CONCEALED and EXPOSED URINAL FLUSHOMETERS ode No. 0816164 Rev. 4 (05/09) INSTLLTION INSTRUTIONS FOR OPTIM SYSTEMS SENSOR TIVTED ROYL ONELED and EXPOSED URINL FLUSHOMETERS EXPOSED FLUSHOMETER ONELED FLUSHOMETER Exposed Urinal Flushometers 1-1/4"

More information

INSTALLATION INSTRUCTIONS FOR CONCEALED CLOSET AND URINAL FLUSHOMETERS

INSTALLATION INSTRUCTIONS FOR CONCEALED CLOSET AND URINAL FLUSHOMETERS Code No. 0816170 Rev. 2 (12/11) INSTLLTION INSTRUCTIONS FOR CONCELED CLOSET ND URINL FLUSHOMETERS Model 140 Model 195 Concealed Closet Flushometer 1-1/2 Exposed ack Spud MODEL 140 MODEL 154 Concealed Closet

More information

INSTALLATION INSTRUCTIONS FOR EXPOSED GEM 2 PISTON TYPE WATER CLOSET AND URINAL FLUSHOMETERS

INSTALLATION INSTRUCTIONS FOR EXPOSED GEM 2 PISTON TYPE WATER CLOSET AND URINAL FLUSHOMETERS ode No. 0816178 Rev. (04/07) INSTLLTION INSTRUTIONS FOR EXPOSE GEM PISTON TYPE WTER LOSET N URINL FLUSHOMETERS loset Flushometer for 1½ Top Spud MOELS 110/111, 115 & 136 Urinal Flushometer for 1¼ Top Spud

More information

BASYS Infrared Sensor Activated

BASYS Infrared Sensor Activated EFX-1XX SERIES EFX-2XX SERIES 6C 6B 6A 5 3A 4 2 8 16 9 11 17 1 3B 7 PARTS LIST BASYS FAUCETS Item No. Code No. Part No. Description 1. Mid Mount Faucet Assembly Mid Mount Faucet Assembly with Mixer High

More information

INSTALLATION INSTRUCTIONS FOR OPTIMA SYSTEM SENSOR ACTIVATED SLOAN EXPOSED WITH TRUE MECHANICAL OVERRIDE FLUSHOMETERS

INSTALLATION INSTRUCTIONS FOR OPTIMA SYSTEM SENSOR ACTIVATED SLOAN EXPOSED WITH TRUE MECHANICAL OVERRIDE FLUSHOMETERS INSTLLTION INSTRUTIONS FOR OPTIM SYSTEM SENSOR TIVTE SLON EXPOSE WITH TRUE MEHNIL OVERRIE FLUSHOMETERS ode No. 0816375 Rev. 4 (08/17) Exposed loset Flushometers 1-1/2 Top Spud Model 110/111 ES-S TMO Model

More information

INSTALLATION INSTRUCTIONS FOR SENSOR ACTIVATED CROWN & CROWN II FLUSHOMETER EXPOSED CLOSET & URINAL INSTALLATIONS

INSTALLATION INSTRUCTIONS FOR SENSOR ACTIVATED CROWN & CROWN II FLUSHOMETER EXPOSED CLOSET & URINAL INSTALLATIONS ode No. 0816491 Rev. 3 (02/17) INSTLLTION INSTRUTIONS FOR SENSOR TIVTED ROWN & ROWN II FLUSHOMETER EXPOSED LOSET & URINL INSTLLTIONS Exposed loset Flushometer 1-1/2 Top Spud Model 111 ES-S Model 115 ES-S

More information

Installation. Aerada 1200 Series CS Faucet S Battery-Operated Capacitive Sensing Gooseneck Faucet IMPORTANT

Installation. Aerada 1200 Series CS Faucet S Battery-Operated Capacitive Sensing Gooseneck Faucet IMPORTANT Installation erada 1200 Series CS Faucet S53-325 Battery-Operated Capacitive Sensing Gooseneck Faucet Centershank with 4-inch Trim Plate (Optional: 8-inch or No Trim Plate) Table of Contents Supplies Required..................

More information

INSTALLATION INSTRUCTIONS FOR CONCEALED CLOSET AND URINAL FLUSHOMETERS

INSTALLATION INSTRUCTIONS FOR CONCEALED CLOSET AND URINAL FLUSHOMETERS Code No. 0816170 Rev. 3 (04/14) INSTLLTION INSTRUCTIONS FOR CONCELED CLOSET ND URINL FLUSHOMETERS Model 140 Model 195 Concealed Closet Flushometer 1-1/2 Exposed ack Spud MODEL 140 MODEL 154 Concealed Closet

More information

Maintenance Guide. OPTIMA Components:

Maintenance Guide. OPTIMA Components: Maintenance Guide OPTIMA Sensor Activated Flushometers The Sloan OPTIMA automatic electronic Flushometer relies on an infrared sensor to detect a user and activate a flushing cycle. No physical contact

More information

FOR USE WITH SLOAN S ORIGINAL OPTIMA PLUS FLUSHOMETER PRODUCED FROM AND REGAL PRO OPTIMA PLUS PRODUCED AFTER MAY, 2003

FOR USE WITH SLOAN S ORIGINAL OPTIMA PLUS FLUSHOMETER PRODUCED FROM AND REGAL PRO OPTIMA PLUS PRODUCED AFTER MAY, 2003 Maintenance Guide SENSOR OPERATED VALVES FOR USE WITH SLOAN S ORIGINAL OPTIMA PLUS FLUSHOMETER PRODUCED FROM 1992-2003 AND REGAL PRO OPTIMA PLUS PRODUCED AFTER MAY, 2003 The Sloan Valve Company introduced

More information

INSTALLATION INSTRUCTIONS FOR SOLIS SOLAR-POWERED SENSOR-ACTIVATED CONCEALED FLUSHOMETERS

INSTALLATION INSTRUCTIONS FOR SOLIS SOLAR-POWERED SENSOR-ACTIVATED CONCEALED FLUSHOMETERS INSTLLTION INSTRUTIONS FOR SOLIS SOLR-POWERED SENSOR-TIVTED ONELED FLUSHOMETERS ode No. 0816436 Rev. 8 (06/13) oncealed loset Flushometers 1-1/2 Rear Spud Model 8152 SW oncealed Urinal Flushometers 3/4

More information

INSTALLATION INSTRUCTIONS FOR SLIMLINE BEDPAN WASHER WITH EXPOSED ROYAL FLUSHOMETER

INSTALLATION INSTRUCTIONS FOR SLIMLINE BEDPAN WASHER WITH EXPOSED ROYAL FLUSHOMETER BPWL I.I. Code No. 0816191 Rev. 1 INSTALLATION INSTRUCTIONS FOR SLIMLINE BEDPAN WASHER WITH EXPOSED ROYAL FLUSHOMETER Slimline Bedpan Washers BPW-1000 Standard BPW-1005 With Deoseptic Unit BPW-1010 With

More information

INSTALLATION INSTRUCTIONS OPTIMA SYSTEMS SENSOR OPERATED FLUSHOMETER WITH WALL BOX CONCEALED CLOSET & URINAL INSTALLATIONS

INSTALLATION INSTRUCTIONS OPTIMA SYSTEMS SENSOR OPERATED FLUSHOMETER WITH WALL BOX CONCEALED CLOSET & URINAL INSTALLATIONS -l.l. Code No. 0816168 Rev. 1A INSTALLATION INSTRUCTIONS OPTIMA SYSTEMS OPERATED FLUSHOMETER WITH BOX CONCEALED CLOSET & URINAL INSTALLATIONS Concealed Closet Flushometer with Wall Box 1-1/2" Back Spud

More information

Control Stop. H-710 Stop, chrome plated: Screwdriver Angle Stop with H-573-A Locking Vandal Resistant Cap

Control Stop. H-710 Stop, chrome plated: Screwdriver Angle Stop with H-573-A Locking Vandal Resistant Cap and Maintenance Guide ontrol Stop H-700 Series ak-hek control stops and replacement parts (available for 3/4 and 1 water supply inlet pipes) Replaces H-600 and H-540 Series control stops ONTROL STOP ND

More information

NAVAL INSTALLATION INSTRUCTIONS PISTON TYPE FLUSHOMETER FOR EXPOSED CLOSET AND URINAL INSTALLATIONS LIMITED WARRANTY

NAVAL INSTALLATION INSTRUCTIONS PISTON TYPE FLUSHOMETER FOR EXPOSED CLOSET AND URINAL INSTALLATIONS LIMITED WARRANTY NAVAL NAVAL I.I. Code No. 0816176 Rev. 1 INSTALLATION INSTRUCTIONS PISTON TYPE FLUSHOMETER FOR EXPOSED CLOSET AND URINAL INSTALLATIONS Certified Made in the U.S.A Exposed Closet Flushometer 1-1/2" Top

More information

Control Stop H-700-A 3/4 NPTF inlet for adjustable tail H-700-A 1 NPTF inlet for adjustable tail

Control Stop H-700-A 3/4 NPTF inlet for adjustable tail H-700-A 1 NPTF inlet for adjustable tail and Maintenance Guide ontrol Stop H-700 Series ak-hek control stops and replacement parts (available for 3/4 and 1 water supply inlet pipes) Replaces H-600 and H-540 Series control stops ONTROL STOP ND

More information

G2 Optima Plus Flushometer

G2 Optima Plus Flushometer 3.2.1 For use with Sloan s introduced May, 2003. For older Optima Plus Flushometers (produced from 1992 2003) and Regal Pro Optima Plus Flushometers see pages 3.2.6 thru 3.2.11. SENSOR MODULE COMPONENT

More information

LIMITED WARRANTY. Exposed Urinal Flushometer for 1-1/4" Top Spud MODEL 180 Exposed Urinal Flushometer for 3/4" Top Spud MODEL 186

LIMITED WARRANTY. Exposed Urinal Flushometer for 1-1/4 Top Spud MODEL 180 Exposed Urinal Flushometer for 3/4 Top Spud MODEL 186 ROYAL I.I. Rev. 3 (12/98) Code No. 0816195 Royal Flushometer INSTALLATION INSTRUCTIONS FOR STANDARD EXPOSED WATER CLOSETS AND URINALS NEW! Now featuring Sloan s exclusive Dual Filtered Diaphragm Certified

More information

BASYS Infrared Sensor Activated

BASYS Infrared Sensor Activated Infrared Sensor Activated EFX-XX SERIES EFX-XX SERIES C B A A B. Mid Mount Faucet Assembly Mid Mount Faucet Assembly with Mixer High Mount Faucet Assembly High Mount Faucet Assembly with Mixer. 0 EFX-00-A

More information

INSTALLATION INSTRUCTIONS FOR OPTIMA SYSTEM SENSOR ACTIVATED ROYAL EXPOSED WITH TRUE MECHANICAL OVERRIDE FLUSHOMETERS ROUGH-IN

INSTALLATION INSTRUCTIONS FOR OPTIMA SYSTEM SENSOR ACTIVATED ROYAL EXPOSED WITH TRUE MECHANICAL OVERRIDE FLUSHOMETERS ROUGH-IN ode No. 0816434 Rev. 8 (08/14) INSTLLTION INSTRUTIONS FOR OPTIM SYSTEM SENSOR TIVTE ROYL EXPOSE WITH TRUE MEHNIL OVERRIE FLUSHOMETERS Exposed loset Flushometers 1-1/2 Top Spud Model 110/111 ES-S TMO Model

More information

Reducing Your Water Footprint

Reducing Your Water Footprint ode No. 0816721 Rev. 4 (12/11) INSTLLTION INSTRUTIONS FOR RETROFIT N OMPLETE SLON EOS VLVE INSTLLTION Reducing Your Water Footprint Shown without optional Override utton 8100 HET omplete Flushometer Models

More information

MAC FAUCETS FA400 WALL MOUNT FAUCETS

MAC FAUCETS FA400 WALL MOUNT FAUCETS MAC FAUCETS FA400 WALL MOUNT FAUCETS Installation Procedure: Take a moment to view drawings and read special Installation note on pages 4 and 5 of this manual before proceeding with installation. Connect

More information

Milano AUTOMATIC FAUCET

Milano AUTOMATIC FAUCET Milano AUTOMATIC FAUCET with Surround Sensor Technology Installation & Maintenance IMPORTANT: PLEASE READ ENTIRE INSTRUCTION BOOKLET BEFORE YOU BEGIN INSTALLATION! Looks Clean - Is Clean. AutoFaucet Parts

More information

HYDROTEK INTERNATIONAL, INC Forsyth Commerce Rd., Ste. 124, Orlando, FL Phone (800) / Fax (866)

HYDROTEK INTERNATIONAL, INC Forsyth Commerce Rd., Ste. 124, Orlando, FL Phone (800) / Fax (866) HYDROTEK INTERNATIONAL, INC. 5055 Forsyth Commerce Rd., Ste. 124, Orlando, FL 32807 Phone (800)922-9883 / Fax (866)670-5580 www.hydrotekintl.com OPERATION & MAINTENANCE MANUAL HYDROTEK MODEL #H-1000C FAUCET

More information

MAC FAUCETS. FA400 Autoluxe Faucets

MAC FAUCETS. FA400 Autoluxe Faucets MAC FAUCETS FA400 Autoluxe Faucets Installation Procedure: Take a moment to view drawings and read special Installation note on page 4 of this manual before proceeding with installation. Connect Faucet

More information

INSTALLATION INSTRUCTIONS OPTIMA SYSTEMS SENSOR OPERATED ROYAL FLUSHOMETER CONCEALED & EXPOSED URINAL INSTALLATIONS

INSTALLATION INSTRUCTIONS OPTIMA SYSTEMS SENSOR OPERATED ROYAL FLUSHOMETER CONCEALED & EXPOSED URINAL INSTALLATIONS EL-1500 l.l. Code No. 0816164 Rev. 2 INSTALLATION INSTRUCTIONS OPTIMA SYSTEMS SENSOR OPERATED ROYAL FLUSHOMETER CONCEALED & EXPOSED URINAL INSTALLATIONS Exposed Urinal Flushometer 1-1/4" Top Spud 180 ES-S

More information

Operating Manual for Three-Person Hands-Free Floor Mounted Wash Stations AC Models 56FAL and 56FAL-0.5 Battery Models 56FBL and 56FBL-0.

Operating Manual for Three-Person Hands-Free Floor Mounted Wash Stations AC Models 56FAL and 56FAL-0.5 Battery Models 56FBL and 56FBL-0. HANDS-FREE FLOOR MOUNTED WASH STATIONS AC OR BATTERY POWERED 1 Operating Manual for Three-Person Hands-Free Floor Mounted Wash Stations AC Models 56FAL and 56FAL-0.5 Battery Models 56FBL and 56FBL-0.5

More information

INSTALLATION INSTRUCTIONS OPTIMA SYSTEMS SENSOR OPERATED ROYAL FLUSHOMETER CONCEALED & EXPOSED CLOSET INSTALLATIONS

INSTALLATION INSTRUCTIONS OPTIMA SYSTEMS SENSOR OPERATED ROYAL FLUSHOMETER CONCEALED & EXPOSED CLOSET INSTALLATIONS EL-1500-L l.l. Code No. 08115 Rev. 2 INSTALLATION INSTRUCTIONS OPTIMA SYSTEMS SENSOR OPERATED ROYAL FLUSHOMETER CONCEALED & EXPOSED CLOSET INSTALLATIONS Exposed Closet Flushometer 1-1/2" Top Spud Model

More information

HYDROTEK INTERNATIONAL, INC Forsyth Commerce Rd., Ste. 124, Orlando, FL Phone (800) / Fax (866)

HYDROTEK INTERNATIONAL, INC Forsyth Commerce Rd., Ste. 124, Orlando, FL Phone (800) / Fax (866) HYDROTEK INTERNATIONAL, INC. 5055 Forsyth Commerce Rd., Ste. 124, Orlando, FL 32807 Phone (800)922-9883 / Fax (866)670-5580 www.hydrotekintl.com OPERATION & MAINTENANCE MANUAL HYDROTEK MODEL #H-4000C FAUCET

More information

Operating Manual for Hands-Free Wall Mounted Scrub Sinks AC Models 504A and 504A-0.5 Battery Models 504B and 504B-0.5

Operating Manual for Hands-Free Wall Mounted Scrub Sinks AC Models 504A and 504A-0.5 Battery Models 504B and 504B-0.5 HANDS-FREE WALL MOUNTED SINKS AC OR BATTERY POWERED 1 Operating Manual for Hands-Free Wall Mounted Scrub Sinks AC Models 504A and 504A-0.5 Battery Models 504B and 504B-0.5 Columbia does not recommend use

More information

Installation Instructions

Installation Instructions Instructions Aerada 900 Series Futura Faucet With Battery (BIR) Infrared Control S53-284 4" Centerset/Centershank S53-289 Centerset/Centershank w/plate Table of Contents Pre- Information............2 900

More information

Installation. Tools. Single Handle Kitchen Faucet With Optional Spray. Maintenance. Safety Tips. Important Points. Need Help? For Model:

Installation. Tools. Single Handle Kitchen Faucet With Optional Spray. Maintenance. Safety Tips. Important Points. Need Help? For Model: Installation Tools - Basin Wrench - Adjustable Wrenches - Pipe Wrench - Screwdriver - Thread Seal Tape - Supply Lines - Protective Goggles - Silicone Sealant - Pliers - Soft Cloth For Model: 673-6809 Single

More information

AutoFaucet. with Surround Sensor Technology. Installation & Maintenance

AutoFaucet. with Surround Sensor Technology. Installation & Maintenance AutoFaucet with urround ensor Technology Installation & Maintenance Instalaion y Mantenimiento Installation Et Maintenance on www.technicalconcepts.com or call 800-551-5155 Looks Clean - Is Clean. AutoFaucet

More information

S-9100, S-9200, S-9300, S-9400, S-9700, S-9800

S-9100, S-9200, S-9300, S-9400, S-9700, S-9800 SPEAKMAN COMPANY 1of 18 S-9100, S-9200, S-9300, S-9400, S-9700, S-9800 Series Installation, Maintenance & Operation Instructions SENSORFLO BATTERY or AC POWERED SLIM DESIGN FAUCETS with DIFFERENT OPTIONS

More information

Installation Instructions

Installation Instructions Installation Instructions SERIN Deck Mount Electronic Proximity Lavatory Faucet Optional 0P00.XXX, " Deck Plate Optional 0P800.XXX, 8" Deck Plate Certified to comply with ASME A.8. 0 AS America, Inc. MODEL

More information

Columbia does not recommend use with harsh chemicals. NSF/ANSI Standard 2 - Food Equipment and NSF/ANSI 372 low-lead.

Columbia does not recommend use with harsh chemicals. NSF/ANSI Standard 2 - Food Equipment and NSF/ANSI 372 low-lead. HANDS-FREE WALL MOUNTED WASH STATIONS AC OR BATTERY POWERED 1 Operating Manual for ADA Compliant Three-Person Hands-Free Wall Mounted Wash Stations AC Models 5A3A, 5A3A-1.0 and 5A3A-0.5 Battery Models

More information

Installation For Service Only

Installation For Service Only For Service Only IMPORTANT! Aerada 1100 Series Low Arc Faucet S53-302 Battery Infrared Metering Faucet (Center Shank with 4" Trimplate) THIS SIDE UP! Packing List Read this entire installation manual to

More information

OPERATION & MAINTENANCE MANUAL 6700C Series Faucet

OPERATION & MAINTENANCE MANUAL 6700C Series Faucet Sensor Faucets and Flush Valves OPERATION & MAINTENANCE MANUAL Faucet 5055 Forsyth Commerce Rd, Ste 124, Orlando, FL 32807 Phone (800) 922-9883 Fax (866) 670-5580 ISO 9001 Certified U.S. Patent 6192530B1

More information

MAC FAUCETS. FA400 Wall Mount Sensor

MAC FAUCETS. FA400 Wall Mount Sensor MAC FAUCETS FA400 Wall Mount Sensor Installation Procedure: Take a moment to view drawings and read special Installation note on page 4 of this manual before proceeding with installation. Connect Faucet

More information

Installation Instructions

Installation Instructions Installation Instructions SERIN Deck Mount Electronic Proximity Lavatory Faucet Certified to comply with ASME A.. 0 American Standard Optional 0P00.XXX, " Deck Plate Optional 0P00.XXX, " Deck Plate 0.

More information

INSTALLATION INSTRUCTIONS SLOAN SERIES 900 HYDRAULIC FLUSHING SYSTEM FLUSHOMETERS EXPOSED CLOSET, URINAL & SERVICE SINK INSTALLATIONS.

INSTALLATION INSTRUCTIONS SLOAN SERIES 900 HYDRAULIC FLUSHING SYSTEM FLUSHOMETERS EXPOSED CLOSET, URINAL & SERVICE SINK INSTALLATIONS. HY-EXPOSED-l.l. Code No. 0816300 INSTALLATION INSTRUCTIONS SLOAN SERIES 900 HYDRAULIC FLUSHING SYSTEM FLUSHOMETERS EXPOSED CLOSET, URINAL & SERVICE SINK INSTALLATIONS Exposed Closet Flushometer 1-1/2"

More information

Electronic Faucet 1500T & 1501T Series

Electronic Faucet 1500T & 1501T Series Electronic Faucet 1500T & 1501T Series Specification: (example) Battery (4 cell) or Hardwire (24 V) infrared electronic handwash system H 2OPTIS technology no external adjustments required hrome plated

More information

INSTALLATION AND MAINTENANCE GUIDE SF1596 B/E ELECTRONIC LAVATORY FAUCET

INSTALLATION AND MAINTENANCE GUIDE SF1596 B/E ELECTRONIC LAVATORY FAUCET INSTALLATION AND MAINTENANCE GUIDE SF1596 B/E ELECTRONIC LAVATORY FAUCET 1 INDEX 1 TECHNICAL DATA 2 PACK CONTENTS 3 PRE-INSTALLATION INFO 4-5 INSTALLATION 6-8 SETTINGS ADJUSTMENT WITH REMOTE CONTROL 9

More information

Installation. S AST4 S TouchTime S Infrared. Stainless Steel Wall-Hung BradMate Washfountain

Installation. S AST4 S TouchTime S Infrared. Stainless Steel Wall-Hung BradMate Washfountain S93-572 S93-573 S93-572 ST4 S93-573 TouchTime S93-574 Infrared Stainless Steel Wall-Hung radmate Washfountain S93-574 (Standard* & Juvenile Height) * Standard Height is D Compliant Table of Contents Supplies

More information

Operating Manual for Hands-Free Floor Mounted Scrub Sink Models 532FA and 532FB

Operating Manual for Hands-Free Floor Mounted Scrub Sink Models 532FA and 532FB HANDS-FREE FLOOR MOUNTED SCRUB SINK AC OR BATTERY POWERED 1 Operating Manual for Hands-Free Floor Mounted Scrub Sink Models 532FA and 532FB Columbia does not recommend use with harsh chemicals. NSF/ANSI

More information

INSTALLATION AND MAINTENANCE GUIDE TUBULAR SERIES WALL MOUNTED ELECTRONIC FAUCET FOR COLD OR PREMIXED WATER

INSTALLATION AND MAINTENANCE GUIDE TUBULAR SERIES WALL MOUNTED ELECTRONIC FAUCET FOR COLD OR PREMIXED WATER INSTALLATION AND MAINTENANCE GUIDE TUBULAR SERIES WALL MOUNTED ELECTRONIC FAUCET FOR COLD OR PREMIXED WATER Tubular B Tubular E Tubular CB Tubular CE Tubular 2030 B Tubular 2030 E 1 INDEX 1 TECHNICAL DATA

More information

Installation Instructions

Installation Instructions COLONY/COLONY SOFT Bidet Faucet and Transfer Valve with Speed Connect Drain Congratulations on purchasing your American Standard faucet with the Speed Connect drain, a feature found only on American Standard

More information

Installation S AST4 S TT S IR. Stainless Steel Wall-Hung BradMate Washfountain

Installation S AST4 S TT S IR. Stainless Steel Wall-Hung BradMate Washfountain S93-572 S93-573 S93-572 ST4 S93-573 TT S93-574 IR Stainless Steel Wall-Hung radmate Washfountain S93-574 (Standard* & Juvenile Height) * Standard Height is D Compliant Table of Contents Supplies Required...

More information

EZ FILL FAUCET AUTOMATIC DECK MOUNTED FAUCET INSTALLATION AND MAINTENANCE GUIDE

EZ FILL FAUCET AUTOMATIC DECK MOUNTED FAUCET INSTALLATION AND MAINTENANCE GUIDE EZ FILL FAUCET AUTOMATIC DECK MOUNTED FAUCET INSTALLATION AND MAINTENANCE GUIDE 05 September 018 TABLE OF CONTENTS PRE-INSTALLATION INFORMATION PRE-INSTALLATION INFORMATION 3 PACK CONTENTS 4 TECHNICAL

More information

LIGATURE RESISTANT SENSOR FAUCET

LIGATURE RESISTANT SENSOR FAUCET LIGATURE RESISTANT SENSOR FAUCET PATENT #US D635, 386 #SF370/SAL-5011 INSTALLATION, MAINTENANCE & OPERATION INSTRUCTIONS SENSORFLO BATTERY OR AC POWERED The Ligature Resistant Sensor Faucet was designed

More information

Installation Instructions

Installation Instructions TIMES SQUARE Spread Lavatory Faucet with Speed Connect Drain Installation Instructions 8.80 8.8 Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature found only

More information

Installation Instructions

Installation Instructions Instructions Aerada 90-75 Series Metering Faucet S53-053 90-75 Series Metering Faucet with 4" Centerset S53-082 90-75 Series Metering Faucet with 4" Centerset & 8" Trim Plate S53-058 90-75 Series Metering

More information

Installation Instructions

Installation Instructions Installation Instructions SELECTRONIC Proximity Infection Control Faucet 0 / 0 / 0 Infection Control Faucet shown Installed on American Standard. Infection Control Sink Certified to comply with ASME A..M

More information

Installation Instructions

Installation Instructions Installation Instructions SERIN Wall Mount Electronic Proximity Lavatory Faucet TE: Please refer to R30 Mounting Kit installation instructions #M4 prior to faucet installation. Certified to comply with

More information

Installation Instructions

Installation Instructions Installation Instructions SELECTRONIC Proximity Faucets Cast Spout and Gooseneck Spout Certified to comply with ASME A.8. 0 American Standard 0X.0 0X. MODEL NUMBERS 0X.0 0X. 0X.0 0X. CAUTION: Use only

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS AVERY ELECTRONIC PULL-DOWN KITCHEN FAUCET INSTALLATION INSTRUCTIONS 0.0 Thank you for selecting American Standard... the benchmark of fine quality for over 00 years. To ensure that your installation proceeds

More information

DISCONTINUED. Installation. Aerada 900 Series Futura Faucet. With Accu-Zone (AZ) Infrared Control

DISCONTINUED. Installation. Aerada 900 Series Futura Faucet. With Accu-Zone (AZ) Infrared Control Aerada 900 Series Futura Faucet With Accu-Zone (AZ) Infrared Control BRADLEY SC A S53-141 4" Centerset S53-148 4" Centerset, no Solenoid Valve S53-186 4" Centerset with 8" Trim Plate S53-285 Centershank

More information

INSTALLATION MANUAL IMPORTANT CONSIDERATIONS TECHNICAL INFORMATION. Tools you may need

INSTALLATION MANUAL IMPORTANT CONSIDERATIONS TECHNICAL INFORMATION. Tools you may need Model: IS203, IS203-1-X Three Way Thermostatic Valve 3/4 Rough and Trim Set INSTALLATION MANUAL U P C C Compliance: ASME A112.18.1 CSA B125.1 IMPORTANT CONSIDERATIONS This product and other additional

More information

Aqua-FIT Serio Series TM

Aqua-FIT Serio Series TM Aqua-FIT Serio Series TM Sensor-Operated Lavatory Faucets for Battery or Plug-In Installations. Installation, Operation, Maintenance, and Parts Manual Patented and Patents Pending Z6950-XL-S Z6955-XL-S

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS BEALE ELECTRONIC PULL-DOWN KITCHEN FAUCET INSTALLATION INSTRUCTIONS 0 Thank you for selecting American Standard... the benchmark of fine quality for over 00 years. To ensure that your installation proceeds

More information

Troubleshooting Guide HYBRIDFLUSH AEF-801 SERIES

Troubleshooting Guide HYBRIDFLUSH AEF-801 SERIES PUSH Troubleshooting Guide HYBRIDFLUSH AEF-80 SERIES AUTOMATIC/MANUAL FLUSH VALVE SYSTEM FOR WATER CLOSETS (TOILETS) AND URINALS Advanced Modern Technologies Corporation 9800 Nordhoff Place, Chatsworth,

More information

Installation MF2922/BIR3

Installation MF2922/BIR3 Terreon orner-fount Washfountain with attery Operated Infrared ontrol (Standard, Juvenile and O Height) Table of ontents Pre- Information... 2 Parts Included with the orner-fount... 3 Instructions... 4-8

More information

SAVE FOR CONSUMER INSTALLATION / OWNER'S MANUAL. Single Handle Kitchen Faucet Model # LK2500. Important! You choose the flow rate!

SAVE FOR CONSUMER INSTALLATION / OWNER'S MANUAL. Single Handle Kitchen Faucet Model # LK2500. Important! You choose the flow rate! INSTALLATION / OWNER'S MANUAL Single Handle Kitchen Faucet Model # LK500 Important! You choose the flow rate! This faucet ships with an eco-friendly.5gpm flow regulator installed. If you desire higher

More information

Installation Instructions

Installation Instructions TROPIC Spread Lavatory Faucet with EverClean Finish & SpeedConnect Drain Installation Instructions 708.80 Congratulations on purchasing your American Standard faucet with EverClean finish and Speed Connect

More information

AEF-300/300T SERIES SENSOR FAUCET SYSTEMS

AEF-300/300T SERIES SENSOR FAUCET SYSTEMS Installation and Owner s Manual AEF-300/300T SERIES SENSOR FAUCET SYSTEMS HYBRIDFLO FIXEDFLO HEALTHFLO AEF-300 AEF-301 AEF-302 AEF-303 AEF-304 AEF-306 AEF-307 AEF-320 AEF-321 AEF-322 AEF-323 AEF-300T AEF-302T

More information

Installation Instructions

Installation Instructions Installation Instructions SELECTRONIC Moments Proximity Faucets MODEL NUMBERS 0.X 0.X 0B.0X CAUTION: Use only American Standard supplied cable sets. Using non-as supplied cables, or cutting, splicing or

More information

SB-1821-E. Instructions for Models: What You Need To Know: Tools: Required: Need Help? For additional assistance or service call: Helpful:

SB-1821-E. Instructions for Models: What You Need To Know: Tools: Required: Need Help? For additional assistance or service call: Helpful: Instructions for Models: SB-8 SB-8-E What You Need To Know: Tools: Required: *Adjustable Wrench *Groove Joint Pliers *Philips Screwdriver Important Notes: Be sure to read instructions thoroughly before

More information

HYDROTEK INTERNATIONAL, INC Forsyth Commerce Rd., Ste. 124, Orlando, FL Phone (800) / Fax (866)

HYDROTEK INTERNATIONAL, INC Forsyth Commerce Rd., Ste. 124, Orlando, FL Phone (800) / Fax (866) HYDROTEK INTERNATIONAL, INC. 5055 Forsyth Commerce Rd., Ste. 124, Orlando, FL 32807 Phone (800)922-9883 / Fax (866)670-5580 www.hydrotekintl.com OPERATION & MAINTENANCE MANUAL HYDROTEK MODEL #HB-5000E

More information

Installation Instructions Series Series

Installation Instructions Series Series PORTSMOUTH Spread Lavatory Faucet with Speed Connect Drain Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature found onlyon American Standard faucets. Recommended

More information

INSTALLATION AND MAINTENANCE GUIDE ELITE SERIES ELECTRONIC LAVATORY FAUCET

INSTALLATION AND MAINTENANCE GUIDE ELITE SERIES ELECTRONIC LAVATORY FAUCET INSTALLATION AND MAINTENANCE GUIDE ELITE SERIES ELECTRONIC LAVATORY FAUCET 1 INDEX 1 TECHNICAL DATA 2 PACK CONTENTS 3 PRE-INSTALLATION INFO 4-5 INSTALLATION 6-9 SETTINGS ADJUSTMENT 10 BATTERY REPLACEMENT

More information

Electronic Hand Washing Faucet

Electronic Hand Washing Faucet Sensor Activated Electronic Hand Washing Facet Chrome Plated Brass, Sensor Activated, 4 Center-set Electronic Hand Washing Facet for tempered or hot/cold water operation. 0.5 gpm/1.9 Lpm Vandal Resistant

More information

OPERATION & MAINTENANCE MANUAL 5000E Series Faucet

OPERATION & MAINTENANCE MANUAL 5000E Series Faucet Sensor Faucets and Flush Valves OPERATION & MAINTENANCE MANUAL 5000E Series Faucet www.hydrotekintl.com 5055 Forsyth Commerce Rd, Ste 124, Orlando, FL 32807 Phone (800) 922-9883 Fax (866) 670-5580 Sensor

More information

Installation Instructions JASMINE Spread Lavatory Faucet with the EverClean Finish & Speed Connect Drain

Installation Instructions JASMINE Spread Lavatory Faucet with the EverClean Finish & Speed Connect Drain Installation Instructions JASMINE 80. Spread Lavatory Faucet with the EverClean Finish & Speed Connect Drain Congratulations on purchasing your American Standard faucet with the EverClean finish and Speed

More information

Installation Instructions

Installation Instructions Spread Lavatory Faucet with the Speed Connect Drain Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature found only on American Standard faucets. Speed Connect

More information

PILLOWS DECK-MOUNT BATH FAUCET WITH FLUME SPOUT

PILLOWS DECK-MOUNT BATH FAUCET WITH FLUME SPOUT PILLOWS DECK-MOUNT BATH FAUCET WITH FLUME SPOUT BEFORE YOU BEGIN NOTES Observe all local plumbing and building codes. Advance planning before installation is crucial. Carefully read the entire instructions

More information

EcoVantage AV. ZRK Dual Flush Series. Sensor-Operated, Battery-Powered Retrofit Kit. Installation, Operation, Maintenance, and Parts Manual

EcoVantage AV. ZRK Dual Flush Series. Sensor-Operated, Battery-Powered Retrofit Kit. Installation, Operation, Maintenance, and Parts Manual EcoVantage AV ZRK Dual Flush Series Sensor-Operated, Battery-Powered Retrofit Kit. Installation, Operation, Maintenance, and Parts Manual Patented and Patents Pending Sensor-Operated, Battery-Powered Dual

More information