1 Installation Instructions SELECTRONIC Proximity Infection Control Faucet 0 / 0 / 0 Infection Control Faucet shown Installed on American Standard. Infection Control Sink Certified to comply with ASME A..M 0 American Standard MODEL NUMBERS Product No.'s & Options Specifications How to Install - Electrical Hook-up - Maintenance - FAQ,s Replacement Parts NOTE TO INSTALLER: Please give this manual to the customer after installation. To learn more about American Standard Faucets visit our website at: or U.S. customer's us at: faucetsupport@amstd.com For Parts, Service, Warranty or other Assistance, please call (In Canada: ) (In Toronto Area only: -0-0)
2 Thank you for selecting American-Standard...the benchmark of fine quality for over 0 years.to ensure that your installation proceeds smoothly--please read these instructions carefully before you begin. UNPACKING All American Standard Faucets Are Water Tested At Our Factory. Some Residual Water May Remain In The Faucet During Shipping.. Remove the fitting and loose items from the carton. The illustration below shows the fitting and all loose items after they have been removed from the carton. Some items may be packaged partially assembled to other items.. Selectronic Spout Assembly. Mounting Kit. Electrical Enclosure. Supply Hose a. DC Power Supply (for 0 series) b. AC Power Supply (for 0 series). Circuit board. " Deck plate ( optional must be ordered separately). " Deck plate ( optional must be ordered separately). Mixing Valve ( optional must be ordered separately). Installation Instructions. ft. Extension Wire (0 series) a DO NOT REMOVE PROTECTIVE FILM FROM SENSOR EYE UNTIL INSTALLATION IS COMPLETE. s e P r o d SELECTRONIC Proximity Infection Control Faucet MODEL NUMBERS / 0 Infection Control Faucet shown Installed on American Standard. Infection Control Sink Certified to comply with ASME A..M Product No.'s & Options Specifications How to Install - Electrical Hook-up - Maintenance - FAQ,s Replacement Parts 0 American Standard M R E V.. NOTE TO INSTALLER: Please give this manual to the customer after installation. u c Base Product t Single Hole Sink Single Inlet a I n s t a l l a t i o n I n s t ru c t i o n s PRODUCT No.s B How to order the Selectronic Product. Choose Power Supply. Choose Desired Spout " GN Spout b 0P00 Deck Plate Deck Plate (optional) and Hole Sinks Single Inlet To learn more about American Standard Faucets visit our website at: or U.S. customer's us at: faucetsupport@amstd.com For Parts, Service, Warranty or other Assistance, please call (In Canada: ) (In Toronto Area only: -0-0) 0P00 Mixing Valve Mixing Valve (optional) and Hole Sinks Hot and Cold Inlets 0XTMV M R E V..
3 Roughing-in Dimensions GENERAL DESCRIPTION: Electronic faucet with proximity operation. Vandal resistant solid brass construction single post mounting. Operates on DC (battery) or AC permanent power. In-line strainer for solenoid is integral. Single inlet / compression, built-in checks, and flexible stainless steel -/" reach inlet hose for spout connection. (mm) -/" DIA. (mm) " (mm) -/" (mm) -/" MOUNTING SURFACE mm (-/) DIA. 0mm (-/) MAX. mm (-/) mm (-/) mm (-/) mm (-/) 00mm (0") mm (0) /" COMP. RECOMMENDED TOOLS Channel Locks Adjustable Wrench Plumbers' Putty or Caulking Phillips Screwdriver Flat Blade Screwdriver Electric Drill & /" Drill Bit Tape Measure ' INSTALLATION Fig. INSTALL SPOUT ASSEMBLY; Fig. CAUTION Turn off hot and cold water supplies before beginning. Insert WIRES (), FLEX HOSE () and SPOUT SHANK () through center hole of mounting surface. Fig... Assemble "C" WASHER (), STAR WASHER () and LOCKNUT () onto threads of SPOUT SHANK () from underside of mounting surface. Fig. a.. Align FAUCET and tighten LOCKNUT (). Fig. a. Fig. a Note: " and " Deck Plates are available for other installations, see page one for information.
4 MOUNT ENCLOSURE; Fig. NOTE. The illustration shows the Infection Control FAUCET mounted on the American Standard Infection Control Sink. Faucet can be installed on almost any sink or countertop. For Faucet installation on the American Standard Infection Control Sink, see instruction sheet No. 0-0 (Infection Control Sink System) supplied with Sink for more detailed information.. For installation on Infection Control Sink mount ENCLOSURE () on MOUNTING BRACKET () with SCREWS (). Fig. MOUNTING BRACKET " (mm) " (mm) ENCLOSURE MOUNTING HOLES -/" (mm). For all other sinks or countertops determine location of ENCLOSURE (). It must be located within the " (mm) by " (mm) shaded area shown in Figure in order for electrical connections from the spout assembly to be completed. NOTE: ENCLOSURE SUPPLY HOSE is 0". Distance between wall supply and ENCLOSURE () must be taken into consideration.. Remove screws from COVER () and pull off COVER (). Hold the ENCLOSURE () in desired location and mark the four mounting hole locations as shown. Fig... The ENCLOSURE () works best if secured to a wall stud or cross brace within the wall, using the SCREWS () supplied. If the ENCLOSURE () is to be installed on a tile or plaster wall the ANCHORS () and SCREWS () should be used. Fig... For installations on drywall or tiled walls; use ANCHORS () and SCREWS () for securing ENCLOSURE () to finished wall. Drill four /" dia. holes a minimum of -/" deep. Insert the four ANCHORS () flush with face of the finished wall. Align the ENCLOSURE () and Install the MOUNTING SCREWS (). Tighten to secure ENCLOSURE () to mounting surface. CONNECT SPOUT HOSE TO ENCLOSURE; Fig.. Connect SUPPLY NUT () from spout assembly to nipple on top of ENCLOSURE (). Tighten with adjustable wrench to make a water tight connection. Fig.. CONNECT WATER SUPPLY TO ENCLOSURE AND WALL SUPPLY; Fig. NOTE; If using the optional Mixing Valve See Sheet #M0 for installation instructions.. Insert FIBER WASHER () into SUPPLY NUT () on ENCLOSURE ().. Connect SUPPLY NUT () on ENCLOSURE () to FLEXIBLE SUPPLY HOSE (). Tighten to make a water tight connection. Use two wrenches to tighten if necessary. Fig.. SUPPLIES WASTE MOUNTING BRACKET " (mm) 0" (00mm) -/" (mm) NOTE: If using Mixing Valve (optional) See Sheet #M0 for installation instructions. Fig. Fig. Fig. a OTHER SINK INSTALLATION mm (0). Connect FLEXIBLE SUPPLY () directly to wall supply. Connection on FLEXIBLE SUPPLY () is /" compression. Use adjustable wrench to tighten connection. Do not over tighten. Fig. a. Note: FLEXIBLE SUPPLY () measures 0" from the bottom of the ENCLOSURE () base. If additional supply length is required, installer must purchase parts separately. Important: If FLEXIBLE SUPPLY () is too long, loop to avoid kinking. COLD WATER OR TEMPERED WALL SUPPLY
5 ELECTRICAL INSTALLATION Fig. DC VERSION (BATTERY); Fig.. Remove ENCLOSURE COVER (). Fig... Feed the WIRE CONNECTORS () through the top of ENCLOSURE (). Fig. a.. Remove GROMMET () from ENCLOSURE (). Fig... Feed the gray SENSOR WIRE () through GROMMET (), " from CONNECTOR. Fig. b & d Insert gray SENSOR WIRE () into SPLIT PLUG (). Push SPLIT PLUG () into GROMMET () to seal. Fig. d.. Insert GROMMET () back into ENCLOSURE (). Fig. c. Fig. a Fig. b ". Install BATTERY () onto DC circuit board. Fig.e. Note: For BATTERY PACK installation see "Install Battery" page.. Install CIRCUIT BOARD () into ENCLOSURE () with SENSOR WIRE () under BOARD. Fig. c.. Insert SENSOR WIRE CONNECTOR () into CIRCUIT BOARD RECEPTOR (). Fig. e. Fig. c BLACK RED. Connect wires from SENSOR to SOLENOID VALVE () (Red to +, Black to -). Fig. c.. Replace ENCLOSURE COVER (). Tighten cover screws firmly. Fig. d Fig. e
6 AC VERSION; Fig. Fig. CAUTION Before opening ENCLOSURE disconnect AC power supply.. Remove ENCLOSURE COVER (). Fig... Feed the WIRE CONNECTORS () through the top of ENCLOSURE (). Fig. a.. Remove GROMMET () from ENCLOSURE (). Fig... Feed the gray SENSOR WIRE () through GROMMET (), " from CONNECTOR. Fig. b. Insert gray SENSOR WIRE () into SPLIT PLUG (). Push SPLIT PLUG () into GROMMET () to seal. Fig. e. Fig. a Fig. b ". Insert GROMMET () back into ENCLOSURE (). Fig. d.. Remove SPLIT PLUG () from POWER SUPPLY GROMMET (). Insert POWER CORD CONNECTOR () through POWER SUPPLY GROMMET (). Insert POWER CORD () into SPLIT PLUG (). Push SPLIT PLUG () into POWER SUPPLY GROMMET () to seal. Fig. g.. Insert POWER SUPPLY CONNECTOR () into RECEPTOR () on the CIRCUIT BOARD (). Fig. c.. Install CIRCUIT BOARD () into ENCLOSURE () with SENSOR WIRE () under BOARD. Fig. d.. Insert SENSOR WIRE CONNECTOR () into CIRCUIT BOARD RECEPTOR () slot. Fig. f. Fig. c Fig. e POWER SUPPLY CORD Fig. d BLACK RED. Connect wires from SENSOR to SOLENOID VALVE () (Red to +, Black to -). Fig. d.. Replace ENCLOSURE COVER (). Tighten cover screws firmly. Fig. g Fig. f
7 Fig. Unit # Unit # Unit # TWO PIECE GROMMET " FOR AC-VERSION (MULTI HOOK-UP); Fig.,. See AC Version Electrical Hook-up for first unit of the Multi hook-up.. Remove ENCLOSURE COVERS from all ENCLOSURES. Fig. a TWO PIECE GROMMET. Remove SOLID BLACK INSERT() from right side of ENCLOSURE # and replace with gray -PIECE GROMMET (). Replace solid black inserts on Unit # with gray -PIECE GROMMET ().. Take the ft. EXTENSION () from Unit # and install into right side of Unit # and Left side of Unit # insealing wire into SPLIT PLUG () as shown in Fig. a. Push SPLIT PLUG () into GROMMET ().. Insert CONNECTOR from ft. EXTENSION () into CIRCUIT BOARD RECEPTOR () top of Unit # as shown in Fig... Insert other end of ft. EXTENSION into LOWER U GROMMET () of Unit # (approximately " from connector). Fig.. Push SPLIT PLUG () into GROMMET () to seal.. Insert connector of ft. EXTENSION into lower receptor as shown in fig. on CIRCUIT BOARD () of Unit #.. Feed gray sensor wire from Unit # through upper U GROMMET () of Unit # ENCLOSURE " from connector Fig.. Insert wire into SPLIT PLUG (). Push SPLIT PLUG () into GROMMET () to seal. Fig. a. Feed the gray ft. EXTENSION () through ROUND GROMMETS () and U GROMMETS () as illustrated above. Fig. b BLACK RED. Insert GROMMET () back into ENCLOSURE. Fig. b.. Reinstall Circuit Board () into Enclosure with all wires under Board. Fig. b.. Connect Unit # Red and Black Sensor wires To # solenoid valve (Red to +, Black to -). Fig. b.. Repeat Steps through for remaining Units in Multi Hook-up.
8 TEST INSTALLED FAUCET TO ENSURE A LAMINAR WATER FLOW the air must be slowly purged from the spout. To do so, cover the SENSOR () while slowly opening the water supply valves. When the water flows as a solid, smooth, steady stream, uncover the SENSOR () and fully open the water supply valve. Fig.. MAINTENANCE HOW TO CHANGE SENSOR RANGE; (Factory set at ") Fig.. Setting the Detection Zone (Distance): Fig.. Detection Zone: " - " (0mm - 0mm) Default: Set at Factory " (0mm) Remove cover from ENCLOSURE. Disconnect GRAY SENSOR WIRE () from circuit board, then reconnect. Fig.. Fig DETECTION ZONE. While the SENSOR CONTROL LED () is blinking slowly, place your hand - in. (0-0mm) in front of the sensor. Fig. a.. When the LED stops blinking and stays "ON", move your hand to the desired position and hold in place until the LED begins to blink again. Fig. a. Fig.. Once the SENSOR CONTROL LED () begins to blink again, remove your hand from the detection zone. When the flashing stops, the detection distance is set. Fig. a. HAND WASH SENSOR OPERATION; When the Sensor detects a user, the water immediately starts to flow. Water flow will stop Two seconds after user is out of sensor range. The off delay allows the user to comfortably move his hands without the flow cycling on to off. As a precaution, a safety timer will turn off the water, after the sensor has been blocked for seconds. The water will stay off until the blockage is removed from the detection zone. HOW TO INSTALL AND CHANGE BATTERY; Fig.. To install New BATTERY () align and press down BATTERY () (contacts facing downward) into position until tabs lock into place.. To remove the BATTERY () spread the two tabs on the HOLDER () with your thumbs. The BATTERY () will release. Fig. a " - " (0mm - 0mm BLINKING LED BLINKING LED Fig. Fig. BATTERY HOLDER LOCKING TABS UP TO " (0mm). Remove the OLD BATTERY ().. Install NEW BATTERY () (contacts facing downward) into HOLDER () and press down into position until tabs lock into place. Fig.
9 HOW TO CLEAN FILTER; Fig. CAUTION Before opening ENCLOSURE disconnect AC power supply.. Remove ENCLOSURE COVER. Fig.. Close SUPPLY STOP () with mm Hex wrench. Note: Keep water flowing out of faucet while shutting off.. Pull off Red () and Black () CONNECTORS from SOLENOID VALVE ().. Unthread STRAINER () using a /" socket.. Pull out the STRAINER () and clean with an old toothbrush. Rinse thoroughly with water. CLEAN SCREENS. Install the STRAINER () back in its place and tighten with a /" socket. Caution: do not over tighten strainer. Note: It is recommended to clean strainer every months.. Replace ENCLOSURE COVER. Tighten cover screws firmly. HOW TO CLEAN AND REMOVE THE FLOW RESTRICTOR; Fig. Fig.. Remove SET SCREW () with FLAT BLADE SCREWDRIVER (). Pull off SPOUT () from faucet base. Fig. & a. REMOVE SET SCREW (). Remove HOUSING () and remove FLOW RESTRICTOR (). Fig. b.. Rinse clean FLOW RESTRICTOR (). Reassemble and install into SPOUT BASE (). Reassemble SPOUT () onto SPOUT BASE () and tighten SET SCREW (). Fig.. Fig.a Fig.b PULL UP TO REMOVE SPOUT
10 GENERAL CLEANING; Fig. Fig.. For general cleaning use a damp, soft cloth to clean the spout and the sensor.. For cleaning dirt use a soft cloth with diluted dish washing detergent. Wipe the area using a wet cloth and dry using a soft cloth. CAUTION Do not scratch the sensor when cleaning. Avoid using anything that may scratch the spout surface. Never use polishing power, detergent or a nylon scrub brush. They will damage the surface of the spout or Sensor. FAQ'S Q: How will I know if battery needs to be replaced? A: Valve does not open and sensor blinks times interrupted by pause for up to days. Q: Why has the flow rate of the faucet reduced significantly? A: Check and clean aerator and strainer. Q: There is no flow out of faucet when I'm in the sensor range? A: Check sensor. If sensor blinks times interrupted by pause, replace battery, or call Q: Why does the faucet operate the opposite of expected-turns On when not in sensor range, but turns off when in sensor range? A: Sensor wires to solenoid are reversed. Black to - & Red to + is correct. Q: What is the normal operating pressure range? A: Faucet will operate with supply pressures ranging from 0-0 psi.
11 A-000A SPOUT SCREW KIT M-000A " SPOUT KIT M-000A FLOW RESTRICTOR KIT SELECTRONIC Proximity Infection Control Faucet MODEL NUMBERS A-000A BATTERY VCR-P M-000A SENSOR KIT A-000A FAUCET SUPPLY HOSE M-000A MOUNTING KIT M-000A MOUNTING SCREW KIT A0-000A WASHER A-000A SUPPLY HOSE A-000A ft. MULTI EXTENSION WIRE M00-000A DC SOLENOID VALVE ASSEMBLY M0-000A AC SOLENOID VALVE ASSEMBLY A0-000A DC CIRCUIT BOARD A0-000A AC CIRCUIT BOARD Appropriate finish code CHROME 00 0P00 A-000A SOLENOID SCREWS A-000A SOLID GROMMET 0P A MOUNTING NUT M-000A SOLENOID & SCREWS A00-000A FILTER A-000A ROUND GROMMET A00-000A SUPPLY STOP A-000A U GROMMET HOT LINE FOR HELP For toll-free information and answers to your questions, call: (00) - Weekdays :00 a.m. to :00 p.m. EST IN CANADA (TORONTO -0-0-) Weekdays :00 a.m. to :00 p.m. EST Product names listed herein are trademarks of American Standard Inc. American Standard Inc. 0 M0-000A POWER SUPPLY A0-000A POWER SUPPLY GROMMET
Installation Instructions
Installation Instructions SELECTRONIC Moments Proximity Faucets MODEL NUMBERS 0.X 0.X 0B.0X CAUTION: Use only American Standard supplied cable sets. Using non-as supplied cables, or cutting, splicing or
More informationInstallation Instructions
Installation Instructions SELECTRONIC Proximity Integrated Faucet with Optional Above-Deck Mixing Flexible Selectronic Platform with Universal Sensor Easy installation. All electronics in the spout; nothing
More informationInstallation Instructions
Installation Instructions SELECTRONIC Proximity Faucets Cast Spout and Gooseneck Spout Certified to comply with ASME A.8. 0 American Standard 0X.0 0X. MODEL NUMBERS 0X.0 0X. 0X.0 0X. CAUTION: Use only
More informationInstallation Instructions
Installation Instructions SERIN Deck Mount Electronic Proximity Lavatory Faucet Certified to comply with ASME A.. 0 American Standard Optional 0P00.XXX, " Deck Plate Optional 0P00.XXX, " Deck Plate 0.
More informationInstallation Instructions
Installation Instructions SERIN Deck Mount Electronic Proximity Lavatory Faucet Optional 0P00.XXX, " Deck Plate Optional 0P800.XXX, 8" Deck Plate Certified to comply with ASME A.8. 0 AS America, Inc. MODEL
More informationInstallation Instructions
Installation Instructions SELECTRONIC Hard-Wired, AC Powered Proximity Integrated Faucet with Above-Deck Mixing Flexible Selectronic Platform with Universal Sensor Easy installation. All electronics in
More informationInstallation Instructions
Installation Instructions SERIN Wall Mount Electronic Proximity Lavatory Faucet TE: Please refer to R30 Mounting Kit installation instructions #M4 prior to faucet installation. Certified to comply with
More informationInstallation Instructions
Installation Instructions SELECTRONIC Integrated Faucet with Above-Deck Mixing CAUTION: Use only American Standard supplied transformers and cable sets. Using non-as supplied cables, or cutting, splicing
More informationInstallation Instructions
Installation Instructions NextGen Selectronic Integrated Faucet with Optional Above-Deck Mixing & SmarTherm Temperature Limiter CAUTION: Use only American Standard supplied transformers and cable sets.
More informationInstallation Instructions
Installation Instructions NextGen Selectronic Integrated Faucet with Optional Above-Deck Mixing & SmarTherm Temperature Limiter CAUTION: Use only American Standard supplied transformers and cable sets.
More informationInstallation Instructions
Installation Instructions SELECTRONIC PROXIMITY TOILET CONCEALED FLUSH VALVE. &. GPF Certified to comply with ASME A..M 00 AS America, Inc. Concealed Flushometer for -/" Top or Back Spud Bowls MODEL NUMBERS
More informationINSTALLATION INSTRUCTIONS
BEALE ELECTRONIC PULL-DOWN KITCHEN FAUCET INSTALLATION INSTRUCTIONS 0 Thank you for selecting American Standard... the benchmark of fine quality for over 00 years. To ensure that your installation proceeds
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS ICS Sink with Selectronic IC Faucet* Models: 98., 98.00 & 98.50 Introduction: Thank you for selecting our products...products which have been the benchmarks of fine quality for
More informationINSTALLATION INSTRUCTIONS
AVERY ELECTRONIC PULL-DOWN KITCHEN FAUCET INSTALLATION INSTRUCTIONS 0.0 Thank you for selecting American Standard... the benchmark of fine quality for over 00 years. To ensure that your installation proceeds
More informationInstallation Instructions
Installation Instructions SELECTRONIC PROXIMITY DUAL FLUSH TOILET FLUSH VALVE. /. GPF,.8/. GPF Certified to comply with ASME A.9.M 00 AS America, Inc. M90 REV.. Exposed Flushometer for -/" Top Spud Bowls
More informationInstallation Instructions
CLEAN FREESTANDING SINGLE CONTROL BATH FILLER Installation Instructions.9 Thank you for selecting American-Standard... the benchmark of fine quality for over 00 years. To ensure that your installation
More informationINSTALLATION INSTRUCTIONS STUDIO S
INSTALLATION INSTRUCTIONS STUDIO S 70.0 MONOBLOCK LAVATORY FAUCET WITH SPEED CONNECT Thank you for selecting American Standard... the benchmark of fine quality for over 00 years. To ensure that your installation
More informationInstallation Instructions
Installation Instructions SELECTRONIC EXPOSED TOILET FLUSH VALVE AC POWERED PROXIMITY.,.8,.6,.6/. &.8/. GPF Certified to comply with ASME A.9. 0 AS America, Inc. MODEL NUMBERS 6067. 6067. 6067.6 6067.7
More informationInstallation Instructions
Installation Instructions SELECTRONIC EXPOSED TOILET FLUSH VALVE AC POWERED PROXIMITY.,.8,.6,.6/. &.8/. GPF Certified to comply with ASME A.9. 08 AS America, Inc. MODEL NUMBERS 606B. 606B. 606B.6 606B.7
More informationInstallation Instructions
ARIANA IN WALL PRESSURE BALANCING BATH AND SHOWER SETS Installation Instructions 0 0 Thank you for selecting American-Standard...the benchmark of fine quality for over 00 years. To ensure that your installation
More informationInstallation Instructions
Installation Instructions SELECTRONIC DC POWERED PROXIMITY EXPOSED URINAL FLUSH VALVE 0., 0., 0. &.0 GPF Certified to comply with ASME A.9. 0 AS America, Inc. Exposed Flushometer for /" Top Spud Urinals
More informationInstallation Instructions
Installation Instructions SELECTRONIC PROXIMITY CONCEALED URINAL FLUSH VALVE.0, 0. & 0. GPF Certified to comply with ASME A.9. 07 AS America, Inc. MODEL NUMBERS 0B.X0 0B.X0 0B.X0 CAUTION: Use only American
More informationInstallation Instructions JASMINE Spread Lavatory Faucet with the EverClean Finish & Speed Connect Drain
Installation Instructions JASMINE 80. Spread Lavatory Faucet with the EverClean Finish & Speed Connect Drain Congratulations on purchasing your American Standard faucet with the EverClean finish and Speed
More informationINSTALLATION INSTRUCTIONS PATIENCE
INSTALLATION INSTRUCTIONS PATIENCE 706.8X DUAL CONTROL WIDESPREAD LAVATORY FAUCET WITH SPEED CONNECT Thank you for selecting American Standard... the benchmark of fine quality for over 00 years. To ensure
More informationInstallation Instructions
TROPIC Spread Lavatory Faucet with EverClean Finish & SpeedConnect Drain Installation Instructions 708.80 Congratulations on purchasing your American Standard faucet with EverClean finish and Speed Connect
More informationInstallation Instructions
Installation Instructions BEDPAN WASHER For Use with Exposed Flushometer and -/" Top Spud Toilets Certified to comply with: ASSE 07 CSA B. ADA Compliant 0 AS America, Inc. M960 607.800 607.8 MODEL NUMBERS
More informationInstallation Instructions
Installation Instructions SELECTRONIC CONCEALED TOILET FLUSH VALVE.,.8 &. GPF Certified to comply with ASME A.9. 0 AS America, Inc. MODEL NUMBERS 0B.XX Exposed Back Spud Concealed Back Spud Top Spud CAUTION:
More informationInstallation Instructions
TIMES SQUARE Spread Lavatory Faucet with Speed Connect Drain Installation Instructions 8.80 8.8 Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature found only
More informationInstallation Instructions
COLONY/COLONY SOFT Bidet Faucet and Transfer Valve with Speed Connect Drain Congratulations on purchasing your American Standard faucet with the Speed Connect drain, a feature found only on American Standard
More informationEDGEMERE DUAL CONTROL WIDESPREAD LAVATORY FAUCET INSTALLATION INSTRUCTIONS
EDGEMERE DUAL CONTROL WIDESPREAD LAVATORY FAUCET INSTALLATION INSTRUCTIONS 708.80 Thank you for selecting American Standard... the benchmark of fine quality for over 00 years. To ensure that your installation
More informationInstallation Instructions Series Series
PORTSMOUTH Spread Lavatory Faucet with Speed Connect Drain Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature found onlyon American Standard faucets. Recommended
More informationInstallation Instructions
Installation Instructions for /" top spud Urinals Certified to comply with: ASSE 07 ANSI/ASME A.9. ADA Compliant 0 AS America, Inc. MODEL NUMBERS 0.0 FOR TOP SPUD APPLICATIONS CLOG RESISTANT Self-cleaning
More informationInstallation Instructions
FLUENT Wide Spread Lavatory Faucet with Speed Connect Drain Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature found only on American Standard faucets. Speed
More informationInstallation Instructions 7024
HAMILTON Centerset Lavatory Faucet with EverClean Finish & Speed Connect Drain Installation Instructions 70 Congratulations on purchasing your American Standard faucet with the EverClean finish and Speed
More informationINSTALLATION INSTRUCTIONS
Flash Shower Valve Rough INSTALLATION INSTRUCTIONS RU0, RU0 RU07, RU08 RU09, RU07E Thank you for selecting American-Standard... the benchmark of fine quality for over 40 years. To ensure that your installation
More informationSERIN MONOBLOCK LAVATORY FAUCET with
SERIN MONOBLOCK LAVATORY FAUCET with Speed Connect Drain Installation Instructions 0.0 Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature found only on American
More informationInstallation Instructions
Installation Instructions COMMERCIAL SYSTEM KITS: 1.5gpm & 2.5gpm 1662.224 1662.214 Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years. To ensure that your installation
More informationInstallation Instructions
Installation Instructions for -/" Top Spud Fixtures MODEL NUMBERS 607 Series 707 Series OPERATING PRESSURE: Overall Range: 0- psi ** Recommended: psi (flowing) - 80 psi (static) FLOW REQUIREMENT: gpm (9.6
More informationInstallation Instructions
Spread Lavatory Faucet with the Speed Connect Drain Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature found only on American Standard faucets. Speed Connect
More informationInstallation Instructions 1662SG SG.222
COMMERCIAL SHOWER SYSTEM KITS: 1. gpm & 2. gpm Installation Instructions 12SG.212 12SG.222 12SG.212 (1.gpm) 12SG.222 (2.gpm) Thank you for selecting American-Standard...the benchmark of fine quality for
More informationInstallation Instructions 1662SG SG.224
COMMERCIAL SHOWER SYSTEM KITS: 1. gpm &. gpm Installation Instructions 1SG.1 1SG. Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years. To ensure that your installation
More informationInstallation Instructions 1662SG SG.223
COMMERCIAL SHOWER SYSTEM KITS: 1. gpm &. gpm Installation Instructions 1SG.1 1SG. Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years. To ensure that your installation
More informationInstallation Instructions
Installation Instructions MANUAL FLUSH VALVE,. GPF Exposed Flushometer for /" top spud Urinals Certified to comply with: ASSE 07 ANSI/ASME A.9. ADA Compliant 0 AS America, Inc. M9600 Rev.. MODEL NUMBERS
More informationInstallation Instructions
Installation Instructions MANUAL FLUSH VALVE with BEDPAN WASHER For Use with -/" Top Spud Toilets 607.860 (.6gpf) 607.80 (.8gpf) Certified to comply with: ASSE 07 CSA B. ADA Compliant 0 AS America, Inc.
More informationINSTALLATION INSTRUCTIONS
COMMERCIAL SYSTEM KITS: 1.5 gpm & 2.5 gpm Thank you for selecting American Standard... the benchmark of fine quality for over 100 years. To ensure that your installation proceeds smoothly-please read these
More informationInstallation Instructions Series
PORTSMOUTH MONOBLOCK LAVATORY FAUCET with Speed Connect Drain Installation Instructions 70.0 7.0 Series 7.0 Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature
More informationInstallation Instructions
CADET Centerset Lavatory Faucet with Speed Connect Drain Installation Instructions Congratulations on purchasing your American Standard faucet with the Speed Connect Drain, a feature found only on American
More informationInstallation Instructions
BERWICK / BOULEVARD MONOBLOCK LAVATORY FAUCET with Speed Connect Drain Installation Instructions 70.0 7.0 Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature
More informationINSTALLATION INSTRUCTIONS
COMMERCIAL SYSTEM KITS: 1.5 gpm & 2.5 gpm Thank you for selecting American Standard... the benchmark of fine quality for over 100 years. To ensure that your installation proceeds smoothly-please read these
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS Randall Single Lever Lavatory and Vessel Faucets Lavatory Model D500C Vessel Model D505C Model D506C Thank you for selecting DXV. To ensure that your installation proceeds smoothly,
More informationEBF-750 Deck-Mounted Battery Powered Sensor Operated Gooseneck Faucets
INSTALLATION INSTRUCTIONS BATTERY POWERED SENSOR OPERATED HAND WASHING FAUCETS EBF-750 I.I. Code No. 0816324 EBF-750 Deck-Mounted Battery Powered Sensor Operated Gooseneck Faucets Includes Instructions
More informationOperating Manual for Hands-Free Wall Mounted Scrub Sinks AC Models 504A and 504A-0.5 Battery Models 504B and 504B-0.5
HANDS-FREE WALL MOUNTED SINKS AC OR BATTERY POWERED 1 Operating Manual for Hands-Free Wall Mounted Scrub Sinks AC Models 504A and 504A-0.5 Battery Models 504B and 504B-0.5 Columbia does not recommend use
More informationOperating Manual for Three-Person Hands-Free Floor Mounted Wash Stations AC Models 56FAL and 56FAL-0.5 Battery Models 56FBL and 56FBL-0.
HANDS-FREE FLOOR MOUNTED WASH STATIONS AC OR BATTERY POWERED 1 Operating Manual for Three-Person Hands-Free Floor Mounted Wash Stations AC Models 56FAL and 56FAL-0.5 Battery Models 56FBL and 56FBL-0.5
More informationInstallation Instructions
Instructions Aerada 900 Series Futura Faucet With Battery (BIR) Infrared Control S53-284 4" Centerset/Centershank S53-289 Centerset/Centershank w/plate Table of Contents Pre- Information............2 900
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS Keefe Single Lever Faucet Monoblock Vessel Model D505C Monoblock Model D500C Thank you for selecting DXV. To ensure that your installation proceeds smoothly, please read these
More informationInstallation Instructions
Reliant Single Control Centerset Lavatory Faucet with SpeedConnect Drain Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature found only on American Standard
More informationInstallation For Service Only
For Service Only IMPORTANT! Aerada 1100 Series Low Arc Faucet S53-302 Battery Infrared Metering Faucet (Center Shank with 4" Trimplate) THIS SIDE UP! Packing List Read this entire installation manual to
More informationColumbia does not recommend use with harsh chemicals. NSF/ANSI Standard 2 - Food Equipment and NSF/ANSI 372 low-lead.
HANDS-FREE WALL MOUNTED WASH STATIONS AC OR BATTERY POWERED 1 Operating Manual for ADA Compliant Three-Person Hands-Free Wall Mounted Wash Stations AC Models 5A3A, 5A3A-1.0 and 5A3A-0.5 Battery Models
More informationOperating Manual for Hands-Free Floor Mounted Scrub Sink Models 532FA and 532FB
HANDS-FREE FLOOR MOUNTED SCRUB SINK AC OR BATTERY POWERED 1 Operating Manual for Hands-Free Floor Mounted Scrub Sink Models 532FA and 532FB Columbia does not recommend use with harsh chemicals. NSF/ANSI
More informationETF-600 Sensor Operated Lavatory Faucet
INSTALLATION INSTRUCTIONS OPTIMA SYSTEMS SENSOR OPERATED LAVATORY FAUCET ETF-600 I.I. Code No. 0816318 ETF-600 Sensor Operated Lavatory Faucet Includes Instructions for Installation of Optional Back Checks
More informationInstallation Instructions
REPRISE TRIM KIT Installation Instructions 555.0 555.0 T55.0 Thank you for selecting Porcher Products. To ensure that your installation proceeds smoothly--please read these instructions carefully before
More informationS-9100, S-9200, S-9300, S-9400, S-9700, S-9800
SPEAKMAN COMPANY 1of 18 S-9100, S-9200, S-9300, S-9400, S-9700, S-9800 Series Installation, Maintenance & Operation Instructions SENSORFLO BATTERY or AC POWERED SLIM DESIGN FAUCETS with DIFFERENT OPTIONS
More informationBattery Powered Sensor Operated Lavatory Faucets. Plug-in Transformer Powered Sensor Operated Lavatory Faucets PARTS LIST
1A 1B 8 EAF-100/150 I.I. Rev. 0a (11/02) Code No. 0816542 INSTALLATION INSTRUCTIONS ELECTRONIC, SENSOR OPERATED LAVATORY FAUCETS EAF-150 Series Battery Powered Sensor Operated Lavatory Faucets 2 3 7 10
More informationInstallation Instructions To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin.
Single Lever Vessel Faucet Installation Instructions To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin. P r o d u c t s Luxury Faucets and Accessories
More informationHYDROTEK INTERNATIONAL, INC Forsyth Commerce Rd., Ste. 124, Orlando, FL Phone (800) / Fax (866)
HYDROTEK INTERNATIONAL, INC. 5055 Forsyth Commerce Rd., Ste. 124, Orlando, FL 32807 Phone (800)922-9883 / Fax (866)670-5580 www.hydrotekintl.com OPERATION & MAINTENANCE MANUAL HYDROTEK MODEL #H-4000C FAUCET
More informationTools Needed for Mounting Cleá Filling Station
ALWAYS OBSERVE PRODUCT SAFETY AND HANDLING INSTRUCTIONS. ALWAYS DIRECT DISCHARGE AWAY FROM YOU or other persons. ALWAYS DISPENSE CLEANERS AND CHEMICALS AS DIRECTED ON THE LABEL. ALWAYS DISPENSE INTO APPROVED
More informationDISCONTINUED. Installation. Aerada 900 Series Futura Faucet. With Accu-Zone (AZ) Infrared Control
Aerada 900 Series Futura Faucet With Accu-Zone (AZ) Infrared Control BRADLEY SC A S53-141 4" Centerset S53-148 4" Centerset, no Solenoid Valve S53-186 4" Centerset with 8" Trim Plate S53-285 Centershank
More information6-12 WIDESPREAD 6-12 W. Cleopatra Series INSTRUCTION GUIDE SAVE THIS INSTRUCTION GUIDE
INSTRUCTION GUIDE STEP-BY-STEP ILLUSTRATED INSTALLATION INSTRUCTIONS TROUBLE SHOOTING & REPAIR TIPS 20 YEAR LIMITED WARRANTY PROPER FINISH CARE Read these instructions carefully before installing your
More informationInstallation Instructions To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin.
Widespread Lavatory Faucet Installation Instructions To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin. P r o d u c t s L u x u r y F a u c e
More informationAEF-300/300T SERIES SENSOR FAUCET SYSTEMS
Installation and Owner s Manual AEF-300/300T SERIES SENSOR FAUCET SYSTEMS HYBRIDFLO FIXEDFLO HEALTHFLO AEF-300 AEF-301 AEF-302 AEF-303 AEF-304 AEF-306 AEF-307 AEF-320 AEF-321 AEF-322 AEF-323 AEF-300T AEF-302T
More informationInstallation Instructions
Instructions Aerada 90-75 Series Metering Faucet S53-053 90-75 Series Metering Faucet with 4" Centerset S53-082 90-75 Series Metering Faucet with 4" Centerset & 8" Trim Plate S53-058 90-75 Series Metering
More informationOPERATION & MAINTENANCE MANUAL 6700C Series Faucet
Sensor Faucets and Flush Valves OPERATION & MAINTENANCE MANUAL Faucet 5055 Forsyth Commerce Rd, Ste 124, Orlando, FL 32807 Phone (800) 922-9883 Fax (866) 670-5580 ISO 9001 Certified U.S. Patent 6192530B1
More information3.1 DISPENSER BLACK SHADOW SERIES. Tools Needed for Mounting SCS Dispenser Hammer
SCS 2 BLACK SHADOW SERIES 3.1 DISPENSER ALWAYS OBSERVE PRODUCT SAFETY AND HANDLING INSTRUCTIONS. ALWAYS DIRECT DISCHARGE AWAY FROM YOU or other persons. ALWAYS DISPENSE CLEANERS AND CHEMICALS AS DIRECTED
More informationInstallation Instructions
Installation Instructions To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin. P r o d u c t s Luxury Faucets and Accessories Savina Product Numbers
More informationInstallation. Aerada 1200 Series CS Faucet S Battery-Operated Capacitive Sensing Gooseneck Faucet IMPORTANT
Installation erada 1200 Series CS Faucet S53-325 Battery-Operated Capacitive Sensing Gooseneck Faucet Centershank with 4-inch Trim Plate (Optional: 8-inch or No Trim Plate) Table of Contents Supplies Required..................
More informationSB-1821-E. Instructions for Models: What You Need To Know: Tools: Required: Need Help? For additional assistance or service call: Helpful:
Instructions for Models: SB-8 SB-8-E What You Need To Know: Tools: Required: *Adjustable Wrench *Groove Joint Pliers *Philips Screwdriver Important Notes: Be sure to read instructions thoroughly before
More informationMAC FAUCETS. FA400 Autoluxe Faucets
MAC FAUCETS FA400 Autoluxe Faucets Installation Procedure: Take a moment to view drawings and read special Installation note on page 4 of this manual before proceeding with installation. Connect Faucet
More informationOperating Manual for Hands-Free Wall Mounted Sinks Models 607D and 607D-0.5
1 Operating Manual for Hands-Free Wall Mounted Sinks Models 607D and 607D-0.5 Columbia does not recommend use with harsh chemicals. NSF/ANSI Standard 2 - Food Equipment and NSF/ANSI 372 low-lead. 2 Parts
More informationInstallation Instructions
Installation Instructions To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin. P r o d u c t s Luxury Faucets and Accessories Savina Product Numbers
More informationPILLOWS DECK-MOUNT BATH FAUCET WITH FLUME SPOUT
PILLOWS DECK-MOUNT BATH FAUCET WITH FLUME SPOUT BEFORE YOU BEGIN NOTES Observe all local plumbing and building codes. Advance planning before installation is crucial. Carefully read the entire instructions
More informationSPEAKMAN. SEF-1800-CA, SEF-1800-CA-TW, SEF-1800-CA-8, SEF-1800-CA-8-TW Installation, Maintenance & Operation Instructions EYESAVER FAUCET
SEF-1800-CA, SEF-1800-CA-TW, SEF-1800-CA-8, SEF-1800-CA-8-TW Installation, Maintenance & Operation Instructions EYESAVER FAUCET DESCRIPTION The SEF-1800-CA Eyesaver faucet combines a gooseneck faucet with
More informationTHIS PRODUCT IS FOR PROFESSIONAL LABORATORY USE ONLY USER'S MANUAL. WELLS ENGINE UNIT 230 VOLT Product No. U905, U906, U907, U908
DENTAL, INC. TECHNICAL BULLETIN U807-022510 5860 FLYNN CREEK ROAD READ ALL INSTRUCTIONS P.O. BOX 106 BEFORE PROCEEDING COMPTCHE, CALIFORNIA, U.S.A. 95427 SAVE THIS FOR FUTURE REFERENCE THIS PRODUCT IS
More informationG SERIES - E TOUCH MIXER / TAP
PLUMBERS Installation and maintenance INSTRUCTIONS G SERIES - E TOUCH MIXER / TAP electronically operated MIXER / TAP G Series E Touch Basin Tap G Series E Touch Basin Mixer 1 IS1301C (03/15) INDEX 3 IMPORTANT
More informationHYDROTEK INTERNATIONAL, INC Forsyth Commerce Rd., Ste. 124, Orlando, FL Phone (800) / Fax (866)
HYDROTEK INTERNATIONAL, INC. 5055 Forsyth Commerce Rd., Ste. 124, Orlando, FL 32807 Phone (800)922-9883 / Fax (866)670-5580 www.hydrotekintl.com OPERATION & MAINTENANCE MANUAL HYDROTEK MODEL #H-1000C FAUCET
More informationInstallation Kitchen Faucet Filtration System Instructions GXK285JBL
Installation Kitchen Faucet Filtration System Instructions GXK285JBL BEFORE YOU BEGIN Read these instructions completely and carefully. IMPORTANT Save these instructions for local inspector s use. IMPORTANT
More informationINSTALLATION AND MAINTENANCE GUIDE ELITE SERIES ELECTRONIC LAVATORY FAUCET
INSTALLATION AND MAINTENANCE GUIDE ELITE SERIES ELECTRONIC LAVATORY FAUCET 1 INDEX 1 TECHNICAL DATA 2 PACK CONTENTS 3 PRE-INSTALLATION INFO 4-5 INSTALLATION 6-9 SETTINGS ADJUSTMENT 10 BATTERY REPLACEMENT
More informationInstallation. Tools. Single Handle Kitchen Faucet With Optional Spray. Maintenance. Safety Tips. Important Points. Need Help? For Model:
Installation Tools - Basin Wrench - Adjustable Wrenches - Pipe Wrench - Screwdriver - Thread Seal Tape - Supply Lines - Protective Goggles - Silicone Sealant - Pliers - Soft Cloth For Model: 673-6809 Single
More informationInstallation Instructions
Installation Instructions To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin. P r o d u c t s Luxury Faucets and Accessories Contemporary Floor
More informationInstallation Instructions To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin.
Installation Instructions To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin. P r o d u c t s Luxury Faucets and Accessories Stoic Product Numbers
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS MODEL: GRAFTON RH-510 1 REV.A Restoration Hardware Balance Pressure Tub /Shower Set Specification Diagram Ensure that the stop ring () is correctly installed, prior to finished
More informationAutoFaucet. with Surround Sensor Technology. Installation & Maintenance
AutoFaucet with urround ensor Technology Installation & Maintenance Instalaion y Mantenimiento Installation Et Maintenance on www.technicalconcepts.com or call 800-551-5155 Looks Clean - Is Clean. AutoFaucet
More informationD28 SERIES WALL MOUNTED ELECTRONIC FAUCET FOR COLD OR PREMIXED WATER. D28 B D28 E D28 Dual Power B D28 Dual Power E D28 Box D28 Box E
D28 SERIES WALL MOUNTED ELECTRONIC FAUCET FOR COLD OR PREMIXED WATER D28 B D28 E D28 Dual Power B D28 Dual Power E D28 Box D28 Box E 1 INDEX 1 TECHNICAL DATA 2-4 PACK CONTENTS 5 PRE-INSTALLATION INFO 6-11
More informationPG-35AV-CH Coiled Hose and Spray Valve. PG-8WSAV-08 Lighweight Aluminum Spray Unit
A Pet-Care Pre-Rinse Plumbing Units Products RINSE UNITS T&S Quality Pet-Care Plumbing Products Wash and Rinse Products Replacement Parts Model # Description EB-10K Repair Kit 013539-45 Replacement Hose
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS MODEL: LUGARNO 23580075 (RH-5910) 23580134 (RH-5910L) 1 REV C Restoration Hardware Faucet Product Size Specification Diagram Dimensions are in Inches and Approximation of a Typical
More information2-DOOR LAUNDRY CABINET KIT
2-DOOR LAUNDRY CABINET KIT OWNER S MANUAL QL054 # 6725159 Table of Contents Table of Contents....2 Safety Information....2 Warranty....3 Warranty Claim Procedure....3 Pre-Installation....4 Tools/Materials
More informationHYDROTEK INTERNATIONAL, INC Forsyth Commerce Rd., Ste. 124, Orlando, FL Phone (800) / Fax (866)
HYDROTEK INTERNATIONAL, INC. 5055 Forsyth Commerce Rd., Ste. 124, Orlando, FL 32807 Phone (800)922-9883 / Fax (866)670-5580 www.hydrotekintl.com OPERATION & MAINTENANCE MANUAL HYDROTEK MODEL #HB-5000E
More informationT&S BRASS AND BRONZE WORKS, INC.
Saddleback Cove / P.O. Box 088 Travelers Rest, SC 9690 EC-30-SM Travelers Rest, SC: 800-476-403 Simi Valley, CA: 800-43-050 Fax: 864-834-358 www.tsbrass.com " [5mm] Faucet [0mm] Deck Mounting Hole Detail
More informationMilano AUTOMATIC FAUCET
Milano AUTOMATIC FAUCET with Surround Sensor Technology Installation & Maintenance IMPORTANT: PLEASE READ ENTIRE INSTRUCTION BOOKLET BEFORE YOU BEGIN INSTALLATION! Looks Clean - Is Clean. AutoFaucet Parts
More informationMAC FAUCETS FA400 WALL MOUNT FAUCETS
MAC FAUCETS FA400 WALL MOUNT FAUCETS Installation Procedure: Take a moment to view drawings and read special Installation note on pages 4 and 5 of this manual before proceeding with installation. Connect
More informationINSTALLATION MANUAL Aplos Single Handle Vessel Bathroom Faucet KEF I toll free: I Kraus USA Inc. I REV
INSTALLATION MANUAL Aplos Single Handle Vessel Bathroom Faucet KEF-15300 www.kraususa.com I toll free: 1.800.775.0703 I 2014-2015 Kraus USA Inc. I REV. August 18, 2016 PRIOR TO INSTALLATION Make sure you
More information