GROUNDING AND BONDING

Size: px
Start display at page:

Download "GROUNDING AND BONDING"

Transcription

1 GROUNDING AND ONDING PANDUIT grounding and bonding solutions meet customer needs and today s critical application requirements for grounding data centers and telecommunication spaces.panduit STRUCTUREDGROUND Grounding provides a high quality, visually verifiable, and dedicated grounding path to maintain system performance and protect network equipment and personnel. PANDUIT grounding and bonding components are designed for use on racks and cabinets which meet EIA-30- A. Ensures highest network system performance Prevents equipment damage Maximizes uptime Meets TIA-942, J--607-A, IEEE Std 00 (IEEE Emerald ook), UL and CSA Promotes personnel protection Designed for flexibility and easy installation STRUCTUREDGROUND Grounding components provide a low resistance grounding path for reliability; include factory terminated jumpers for easy installation; and are kitted for convenience. Jumper kits include PANDUIT Compression Electrical Connectors that meet NES Level 3 Criteria, the highest level of operability within the network facility environment. A full line of manual, controlled cycle, and battery operated hydraulic crimping tools meet application needs and provide lowest installed cost. For the complete line of PANDUIT Electrical and Grounding Connectors and crimping tools, visit or refer to the Electrical Solutions Catalog SA-ELC0. For service and technical support, call (outside the U.S. and Canada, see back c).

2 A. THE PURPOSE OF GROUNDING AND ONDING The grounding and bonding system is more than just an insurance policy against a lightning strike or other surge event. It is an active, functioning system that provides protection for personnel and equipment. Proper grounding and bonding are essential for efficient network performance in the modern data center and telecommunication spaces. A primary purpose of the grounding and bonding system is to create an adequate-capacity path for electrical surges and transient voltages to return to their source (which may include the earth). Lightning, fault currents, circuit switching (motors turning on and off), activation of surge protective devices (SPDs) and electrostatic discharge are common causes of these electrical surges and transient voltages. An effective grounding and bonding system minimizes the detrimental effects of these electrical surges and transient voltages. A properly designed grounding and bonding system is intentional, visually verifiable, and adequately sized to handle expected currents safely and without undue effect on susceptible electronic equipment. Any metallic component that is part of the data center infrastructure (such as equipment, racks, ladder racks, cabinets, cable trays, etc.) must be properly connected to the grounding and bonding system. WHAT ARE THE EFFECTS OF IMPROPER GROUNDING? Lower Reliability An improperly designed grounding (and bonding) system may be a primary source of interference and emission According to the IEEE, the typical AC third-prong ground circuit is almost never sufficient to prevent damage to network equipment susceptible to ground-fault related potentials Poorly designed or improperly applied grounding, bonding, and shielding techniques often adversely affect the performance of electronic equipment from the circuit board to the network system Approximately 70% of all anomalies, dysfunctions, or problems associated with power distribution systems are directly or indirectly related to bonding and grounding issues (4) Safety Risks Personal injury from electric shock caused by improper grounding and bonding can cause immeasurable human suffering and significant expense Potential fire hazards exist when heat is generated from electrical surges that occur on a high impedance grounding and bonding path. Ott, Henry. Noise Reduction Techniques in Electronic., 2nd edition. NY: Wiley-Interscience, Institute of Electrical and Electronics Engineers. IEEE Std IEEE Recommended Practice for ing and Grounding Electronic Equipment. 3. Quoted from Doug Dorr, Senior Project Manager, EPRI and William ush, Director of Research and Grounding, PANDUIT Laboratories. oth serve on the IEEE P00 committee (Emerald ook) in leadership positions and also on the IEEE SPD committee, as well as other standards organizations. 4. Quoted from S. Frank Waterer, Electrical Engineering, Fellow, at Schneider Electric with 30 years experience, Vice-Chair of IEEE/SPDC, NEMA member. 2

3 CAN YOU AFFORD IMPROPER GROUNDING? According to IEEE, grounding and bonding are an essential part of the infrastructure, not just a tool to achieve power quality. Network equipment, such as switches, routers, and storage devices, costs anywhere from thousands of dollars to hundreds of thousands of dollars. The cost of proper grounding is only a tiny fraction of the cost of the equipment it is protecting. Clearly the cost of proper grounding and bonding is a small fraction of the larger cost of improper grounding and bonding mainly, the inability to service customers properly. Protect your infrastructure with the most comprehensive grounding system, designed specifically for easy selection and installation with the highest quality components to minimize your risk. From the data center, to the manufacturing floor, to facilities operations, there are critical systems and equipment that require proper grounding and bonding. Protecting those systems, equipment, and personnel helps to ensure equipment reliability and thus availability of services, while resulting in lower operational expense. Comprehensive, integrated technology from PANDUIT addresses the grounding and bonding needs of the entire infrastructure including electrostatic discharge (ESD) protection, racks, cabinets, enclosures, access floors, control panels, service entrance, and direct burial applications. These industry-leading solutions deliver reliability, availability, safety and lower total cost of ownership. As a solution architecture, the STRUCTUREDGROUND Grounding is complemented by a range of installation tooling, design software, and services. PANDUIT STRUCTUREDGROUND Grounding gives you what you need to properly protect your investment. A.. Ott, Henry, Noise Reduction Techniques in Electronic, 2nd edition, NY; Wiley-Interscience, Institute of Electrical and Electronics Engineers, IEEE Std , IEEE Recommended Practice for ing and Grounding Electronic Equipment. 3. Quoted from Doug Dorr, Senior Project Manager, EPRI and William ush, Director of Research and Grounding, PANDUIT. oth serve on the IEEE P00 committee (Emerald ook) in leadership positions and also on the IEEE SPD committee, as well as other standards organizations. 4. Quoted from S. Frank Waterer, Staff Engineer at Schneider Electric with 30 years experience. For service and technical support, call (outside the U.S. and Canada, see back c). 3

4 A. Common Network (CN) Roadmap PANDUIT STRUCTUREDGROUND Grounding is a complete, highly reliable line of products to ground your building and network equipment in compliance with ICSI TDM Manual,th Edition and J--607-A,TIA-942, IEEE Std 00 (IEEE Emerald ook), UL and CSA Telecommunications Room (see roadmap on page 6) Data Center (see roadmaps on pages 8 9) Service Entrance (see roadmap on page 5) For more data center grounding information, see 4

5 Service Entrance Grounding Roadmap Complies with J--607-A and IEEE Std 00 (IEEE Emerald ook) Grounding Equalizer (GE) is required when two or more Telecommunications ackbones (T) are used within a multi-story building; bond Ts together with a GE at the top floor and at a minimum of every third floor in between 2 Telecommunications ackbone (T)** 3 2 Grounding Equalizer (GE) 5 Conduit A. Earth Ground AC Panel* 2 Compression HTAP and Clear C: HTWC (pages 37 thru 38) ronze, U-olt Grounding Clamp: GPL (page 40) AC Service Entrance Water Meter 4 4 Telecommunications Main Grounding usbar (TMG) and usbar Label (page 29) Telecommunications Grounding and Conductor Label Kit: LTYK (page 29) Entrance 3 Compression, Two-Hole, Long arrel with Window Lug: LCC-W (pages 33 34) 7 Universal eam Grounding Clamp: GUC0-6 (page 3) 4 ronze, Water Pipe Grounding Clamp: KP (page 40) For the complete line of STRUCTURED GROUND Direct urial Compression Grounding, visit *AC panel should be grounded per NEC standards. Enclosure should be grounded per manufacturer s specifications. **Specification J--607-A specifies different size conductors based on the length of the Telecommunications ackbone (T). For service and technical support, call (outside the U.S. and Canada, see back c). 5

6 A. Telecommunications Room Grounding Roadmap Complies with ICSI TDM Manual, th Edition and J--607-A, TIA-942, IEEE Std 00 (IEEE Emerald ook), UL and CSA hardware is recommended to mount all panels, equipment, shelves, etc. to ensure electrical continuity between metallic components and the grounded rack or cabinet Can be used to ground equipment mounted in racks and cabinets which meet EIA-30-D; installer should bond all racks and cabinet members to the grounding strip ack of Racks Shown Grounding Equalizer (GE) Conduit AC Panel* 7 Telecommunications ackbone (T) uilding Steel 2 Compression HTAP and Clear C: HTWC (pages 37 38) ronze, U-olt Grounding Clamp: GPL (page 40) Compression, Two-Hole, Long arrel with Window Lug: LCC-W (pages 33 34) Telecommunications Grounding usbar (TG) and usbar Label (page 29) 6 7 Auxiliary racket: GAC (page 3) Telecommunication Equipment Conductor (TEC) Kits: (pages 2 22) Universal eam Grounding Clamp: GUC0-6 (page 3) 6 *AC panel should be grounded per NEC standards. Enclosure should be grounded per manufacturer s specifications. A typical head cabling system includes a multitude of metallic components which are connected together. It is the responsibility of the installer to insure all of the metallic components are bonded, which means that they are connected together electrically in accordance with applicable specifications. The PANDUIT Grounding and does not insure required bonding of the head cabling system metallic components.

7 Access Floor Mesh Common Network (MCN) Roadmap Complies with ICSI TDM Manual, th Edition and J--607-A, TIA-942, IEEE Std 00 (IEEE Emerald ook), UL and CSA MCN for access floor deployment is recommended in a grid design on 4 foot intervals, allowing for bonding of every other access floor pedestal; this design enables the bonding of at least one pedestal from each access floor tile directly to the MCN network ond all metallic elements to the MCN, including rack/cabinet grounding jumpers, wire basket, water pipes and air conditioning units A Compression HTAP and Clear C: HTWC (pages 37 38) 5 4 Code Conductor, Thin Wall, CTAP: CTAPF (page 39) (Some pedestals lightened for clarity) 2 ronze, U-olt Grounding Clamp: GPL (page 40) 5 Split olt, : SC (page 42) 3 Access Floor Grounding Clamp: GPQC (page 6) 6 GRIDRUNNER (pages 57 6) For service and technical support, call (outside the U.S. and Canada, see back c). 7

8 A. Data Center Rack and Cabinet Grounding Roadmap Complies with ICSI TDM Manual, th Edition and J--607-A, TIA-942, IEEE Std 00 (IEEE Emerald ook), UL, and CSA hardware is recommended to mount all panels, equipment, shelves, etc. to ensure electrical continuity between metallic components and the grounded rack or cabinet Designed for use on racks and cabinets which meet EIA-30-D, see pages 47 for the PANDUIT cabinets, racks, and cable management offering ack of Racks Shown 3 4 Data Equipment Racks AC Panel* uilding Steel Conduit 7 Telecommunications 8 ackbone (T) Mesh Common Network (MCN) Access Floor Pedestal 2 2 Compression HTAP and Clear C: HTWC (pages 37 38) Access Floor Grounding Clamp: GPQC (page 6) Compression, Two-Hole, Long arrel with Window Lug: LCC-W (pages 33 34) Telecommunications Grounding usbar (TG) and usbar Label (page 29) Universal eam Grounding Clamp: GUC0-6 (page 3) 8 *AC panel should be grounded per NEC standards. Enclosure should be grounded per manufacturer s specifications. A typical access floor includes a multitude of metallic components which are connected together. It is the responsibility of the manufacturer and installer of the access floor to insure all the access floor metallic components are bonded which means that they are connected together electrically in accordance with applicable specifications. The PANDUIT Grounding and does not insure required bonding of the access floor metallic components.

9 ack of Cabinets Shown Data Equipment Cabinets A. (Sides/ doors removed for clarity) 7 2 Mesh Common Network (MCN) Access Floor Pedestal 6 Telecommunications Grounding and Conductor Label Kit: LTYK (page 29) 8 Code Conductor, Thin Wall, CTAP: CTAPF (page 39) 7 Surge Suppressor Jumper Kit: SSGK (page 20) *AC panel should be grounded per NEC standards. Enclosure should be grounded per manufacturer s specifications. A typical access floor includes a multitude of metallic components which are connected together. It is the responsibility of the manufacturer and installer of the access floor to insure all the access floor metallic components are bonded which means that they are connected together electrically in accordance with applicable specifications. The PANDUIT Grounding and does not insure required bonding of the access floor metallic components. For service and technical support, call (outside the U.S. and Canada, see back c). 9

10 A. Selection Guide STRUCTUREDGROUND Kits for NET-ACCESS Cabinets Complies with the Telecommunications Standard for Data Centers as described in TIA-942 Maximizes uptime, maintains system performance, and protects network equipment Provides a dedicated, low resistance, and visually verifiable ground system Typical cage nut application Flexible design for use on EIA-30-D compliant cabinets ack of cabinet shown (Sides/doors removed for clarity) Kits for threaded and thru-hole also available Grounding Strip Kit: RGS (page 7) Patent pending hardware provides a bond between grounding strip and cabinet, eliminating the need to scrape paint Electrostatic Discharge (ESD) Port Kit: RGESD (page 24) ent 45 acts as a hook to hold ESD wrist strap Cage Nut: CNK (page 25) Patent pending, bonds equipment and patch panels to cabinet rails Electrostatic Discharge (ESD) Wrist Strap Kits: RGESDWS (page 24) Prevents damaging electrostatic discharge to equipment and personnel Common Network (CN) Jumper Kit: RGCNJ (page 6) Connects grounding busbar to MCN in access floor and head grounding applications Equipment Jumper Kit: RGEJ (page 9) onds network equipment to the grounding strip or grounding busbar Mesh Common Network (MCN) 0

11 Selection Guide STRUCTUREDGROUND Kits for NET-ACCESS Cabinets (continued) Cabinet Grounding Selection in 2 Easy Steps:. What type of fasteners do your mounting rails require? 2. What is the maximum depth of the equipment being mounted? A. Selection Criteria Grounding Strip Kit^ ESD Port Kit (2 required) ESD Wrist Strap ( per ESD Port) Grounding usbar Kit^ Front to ack Rail Jumper Kit^ Common Network (CN) Jumper Kit* Equipment Jumper Kit** Hardware*** PANDUIT NET-ACCESS Cabinets: CN, CN2, CN4, CN5, CNCN, CN2CN, CS, CS2 and CS3. Rail Fasteners Threaded #2-24 RGS34-Y RGESD2- RGESDWS Cage Nut RGS34- RGESD2- RGESDWS EIA-30-D Compliant Cabinets. Rail Fasteners Threaded #2-24 or M6 Cage Nut 2. Rail Depth up to 20" (.5M) STRUCTUREDGROUND Kits for Data Center Cabinet Grounding RGCNJ660P22 GJS660U STRUCTUREDGROUND Kits for Data Center Cabinet Grounding CGJ620U 30" (.75M) RGS34-Y RGESD2- RGESDWS RGR9U CGJ630U 40" (M) CGJ640U 20" (.5M) CGJ620U 30" (.75M) RGS34- RGESD2- RGESDWS RGR9CN CGJ630U 40" (M) CGJ640U RGCNJ660P22 GJS660U RGTSG-C ( Screw) CNK ( Cage Nut) RGTSG-C or RGTSM6G-C CNK ( Cage Nut) ^Grounding strip kits, grounding busbar kits, and front to back rail jumper kits are supplied with mounting hardware based upon rail type. Grounding strip kits include 45 RU strip lengths, additional kits for 42 RU and 47 RU also available. Grounding strip kits also available in packages of ten. ESD port recommended for use on front and back of cabinet. *CN jumper kit supports MCN connection up to #2 (35mm 2 ). Use RGCNJ660PY for cable sizes up to 2kcmil (20mm 2 ). **Additional equipment jumper kits available in different sizes with different termination options, refer to page 9. One equipment jumper kit is required per component. ***Use bonding hardware to mount and bond equipment to the cabinet. Threaded #2-24 rails are included with the CN, CN2, CN4 and CN5 cabinets. Cage nut equipment rails are sold in pairs for the cabinets, order part number CNRC, CNCN, CN2CN, CS, CS2 or CS3. For service and technical support, call (outside the U.S. and Canada, see back c).

12 A. Selection Guide STRUCTUREDGROUND Kits for Racks Complies with the Telecommunications Standard for Data Centers as described in TIA-942 Maximizes uptime, maintains system performance, and protects network equipment Provides a dedicated, low resistance, and visually verifiable ground system Flexible design for use on EIA-30-D compliant racks New installation Typical threaded application ack of rack shown Kits for cage nut and thru-hole also available Screw: RGTS (page 25) Patent pending, bonds equipment and patch panels to the front of the rack. Paint Piercing Grounding Washer Kit: RGW (page 26) Provides a superior bond between frame members, serrations eliminate the need to scrape paint Electrostatic Discharge (ESD) Port Kit: RGESD (page 24) ent 45 acts as a hook to hold ESD wrist strap Equipment Jumper Kit: RGEJ (page 9) onds network equipment to the grounding strip or grounding busbar Electrostatic Discharge (ESD) Wrist Strap Kit: RGESDWS (page 24) Prevents damaging electrostatic discharge to equipment and personnel Common Network (CN) Jumper Kit: RGCNJ (page 6) Connects grounding strip or grounding busbar to MCN in access floor and head grounding applications Grounding Strip Kit: RGS (page 7) Patent pending hardware provides a bond between grounding strip and rack, eliminating the need to scrape paint 2 Mesh Common Network (MCN)

13 Selection Guide STRUCTUREDGROUND Kits for Racks (continued) For PANDUIT racks: Simply find your rack part number and follow across. For other EIA-30-D compliant racks, follow these two easy steps:. What type of installation do you have? 2. What type of fasteners do your mounting rails require? A. Selection Criteria Grounding Strip Kit ESD Port Kit (2 required)* ESD Wrist Strap ( per ESD Port) Grounding usbar Kit Common Network (CN) Jumper Kit Equipment Jumper Kit** Hardware*** PANDUIT Racks 2 Post Racks CMR9X84, CMR9X47, CMR9X84S New Installation CMR9X84, CMR9X47, CMR9X84S Retrofit Installation NFR84 New Installation NFR84 Retrofit Installation 4 Post Racks CMR4P84, CMR4P96 New Installation CMR4P84, CMR4P96 Retrofit Installation CMR4P84CN, CMR4P96CN New Installation CMR4P84CN, CMR4P96CN Retrofit Installation EIA-30-D Compliant Racks RGS34-Y STRUCTUREDGROUND Kits for Data Center Rack Grounding RGESD2- ( each) RGESD-Y and RGESD2- RGESDWS The paint piercing grounding washers work with 3/8" (M8) hardware, for all other sizes, use the grounding solution for retrofit installations. *ESD port recommended for use on front and back of rack. **Additional equipment jumper kits available in different sizes with different termination options, refer to page 9. One equipment jumper kit is required per component. ***Use bonding hardware to mount and bond equipment to the rack. RGR9U RGCNJ660P22 RGRKCNJY RGESDWS RGR9U RGCNJ660P22 GJS660U GJS660U RGS34-Y GJS660U RGESD2- RGESDWS RGR9U GJS660U RGCNJ660P22 RGS34- GJS660U RGESD2- RGESDWS RGR9CN GJS660U RGS34-Y RGESD2- RGESD2A- RGESDWS RGESD2- RGR9U RGCNJ660P22 RGCNJ660P22 RGRKCNJY GJS660U GJS660U RGTSG-C (#2-24) RGTSG-C CGNSK RGTSG-C (#2-24) or RGTSM6G-C (M6) RGTS032G-C (#0-32) or RGTSM5G-C (M5) RGTSG-C (#2-24) or RGTSM6G-C (M6) For service and technical support, call (outside the U.S. and Canada, see back c). 3

14 A. Features and enefits STRUCTUREDGROUND Kits for Cabinets PANDUIT offers a variety of kits with premium components engineered specifically to meet TIA-942 for reliable cabinet grounding. Provides a dedicated, low resistance, and visually verifiable ground system to maximize uptime, maintain data center system performance, and protect network equipment and personnel Incorporates a flexible design that can be used with cabinets which meet EIA-30-D Offers ease of installation no paint scraping required to bond cabinets; factory terminated jumpers simply bolt in place Grounding Strip Kit (see page 7) A C D E F Cage Nut is a unique hardware with paint piercing serrations designed to create a bond point between the cabinet rail and the equipment being installed Grounding Strip is made from high conductivity wrought copper and tin-plated to inhibit corrosion, providing the lowest resistance path to ground Reverse ent Lugs are factory terminated on front to back rail jumper kits to bond the front and back cabinet rails; innovative design maximizes space by utilizing only one RU Studs include patent pending paint piercing serrations to create a bond point between the cabinet rail, strip, busbar and lug; equipment can be installed at any time without removal of stud Grounding usbar is made from high conductivity, low resistance wrought copper and tin-plated to inhibit corrosion Electrostatic Discharge (ESD) Port is made from high conductivity, low resistance copper and tin-plated to inhibit corrosion plus it functions as an ESD wrist strap hanger D H C F A Electrostatic Discharge (ESD) Port Kit (page 24) Equipment Jumper Kit (page 9) Surge Suppressor Jumper Kit (page 20) G H Compression HTAP is UL Listed and CSA Certified; used to make a highly reliable, permanent bond between the mesh common bonding network and common bonding network (CN) jumper kit Jumper has UL, VW- flame rated green-and-yellow insulation and is factory terminated with copper compression, two-hole, long barrel with window lug; lug is UL Listed, CSA Certified and meets NES Level 3 E Grounding usbar Kit (page 7) G Front to ack Rail Jumper Kit (page 8) Common Network (CN) Jumper Kit (page 6) 4 Order number of pieces required, in multiples of Standard Package Quantity. Prime items appear in OL

15 Features and enefits STRUCTUREDGROUND Kits for Racks PANDUIT offers a variety of kits with premium components engineered specifically to meet TIA-942 for reliable rack grounding. Provides a dedicated, low resistance, and visually verifiable ground system to maximize uptime, maintain data center system performance, and protect network equipment and personnel Incorporates a flexible design that can be used with racks which meet EIA-30-D Offers ease of installation no paint scraping required to bond racks; factory terminated jumpers simply bolt in place A A. A C Paint Piercing Grounding Washer is made from hardened steel and electro zinc plated which inhibits corrosion to provide a superior bond between frame members on bolt-together racks Grounding Strip is made from high conductivity wrought copper and tin-plated to inhibit corrosion, providing the lowest resistance path to ground Thread-Forming Screws are made from electro zinc plated steel and provide a bond to the rack by removing paint from threaded holes without creating metal shavings Grounding Strip Kit (page 7) E D C Electrostatic Discharge (ESD) Port Kit (page 24) D Electrostatic Discharge (ESD) Port is made from high conductivity, low resistance copper and tin-plated to inhibit corrosion plus it functions as an ESD wrist strap hanger G E F G Electrostatic Discharge (ESD) Protection Sticker is provided in black and yellow for high visibility and easy identification as an ESD port Compression HTAP is UL Listed and CSA Certified; used to make a highly reliable permanent bond between the mesh common bonding network and common bonding network (CN) jumper kit Jumper has UL, VW- flame rated green-and-yellow insulation and is factory terminated with copper compression, two-hole, long barrel with window lug; lug is UL Listed, CSA Certified and meets NES Level 3 with a single stud hole and slot which allows mounting for /2" to 5/8" hole spacing and accommodates stud sizes /4", #2, and 6mm Equipment Jumper Kit (page 9) Surge Suppressor Jumper Kit (page 20) F Common Network (CN) Jumper Kit (page 6) For service and technical support, call (outside the U.S. and Canada, see back c). 5

16 A. Access Floor Grounding Clamps ond mesh common bonding network (MCN) conductors to each other and bond the access floor pedestals to the conductors Captive u-bolt design utilizes a single hinged bolt to speed installation Specifically designed to bond perpendicular MCN conductors per TIA-942 W Accommodate conductors from #6 /0, minimizes inventory requirements ond round and square access floor pedestals for greater flexibility D H Installed on Pedestal Round Pedestal In. (mm) GPQC07-/0 3/4 7/8 ( ) Square Pedestal In. (mm) MCN Conductor Size Range (mm²) #6 SOL /0 STR (6 ) Figure Dimensions In. (mm) Tightening Torque In. Lbs. (Nm) D W H Conductor Clamp 4.25 (08.0) 3.38 (85.9) 3.9 (8.0) 32 (43.5) 2.5 (7) Ctn. 0 GPQC0-/0 /8 ( ) GPQC2-/0 /4 (3.8) 7/8 (22.2) #6 SOL /0 STR (6 ) #6 SOL /0 STR (6 ) 4.9 (06.4) 4.53 (5.) 3.38 (85.9) 3.44 (87.4) 3.9 (8.0) 3.9 (8.0) 32 (43.5) 32 (43.5) 2.5 (7) 2.5 (7) 0 0 GPQC5-/0 /2 (38.) #6 SOL /0 STR (6 ) 4.47 (3.5) 3.44 (87.4) 3.9 (8.0) 32 (43.5) 2.5 (7) 0 Common Network (CN) Jumper Kits ond the rack or cabinet to the MCN HTAPs, included in kits, require crimping tool and die; see the CT-930 crimping tool on page 43, the CT-293 and CT-293/E crimping tools on page 44 and the CD-930H-2 crimping die on page 45 HTAPs are UL Listed and CSA Certified for applications up to 600 V when crimped with PANDUIT and specified competitor crimping tools and PANDUIT crimping dies Engineered to comply with US and International grounding requirements RGCNJ660P22 RGCNJ660PY MCN Conductor Size (mm 2 ) HTCT2-2- #6 #2 (6 25) HTCT2-2- #2 2 kcmil (35 20) *HTAPs also sold separately, see pages Part Description #6 (6mm²) jumper; 60" (.52m) length; 45 bent lug on grounding strip side; provided with.6 oz. (5cc) of antioxidant, two each #2-24 x /2", M6 x 2mm, #0-32 x /2" and M5 x 2mm thread-forming screws and a copper compression HTAP* for connecting to the MC Ctn Order number of pieces required, in multiples of Standard Package Quantity. Prime items appear in OL

17 A. Grounding Strip Kits onds up to 45 RU per rack EIA Universal mounting hole pattern Engineered to comply with US and International grounding requirements Part Description Grounding Strip Kits for Threaded Rail Fasteners Threaded Rail Kit RGS34-Y Grounding strip; 78.65" (2m) length;.67" (7mm) width;.05" (.27mm) thickness; provided with.6 oz. (5cc) of antioxidant, one grounding sticker and three each #2-24 x /2" and M6 x 2mm thread-forming screws. RGS34-0-Y Ten grounding strips; 78.65" (2m) length;.67" (7mm) width;.05" (.27mm) thickness; provided with.6 oz. (5cc) of antioxidant, ten grounding stickers and 30 each #2-24 x /2" and M6 x 2mm thread-forming screws. Grounding Strip Kits for Cage Nut Rail Fasteners RGS34- Grounding strip; 78.70" (2m) length;.67" (7mm) width;.05" (.27mm) thickness; provided with.6 oz. (5cc) of antioxidant, one grounding sticker, three cage nut bonding studs, eight #2-24 bonding nuts and three strip clips. Cage Nut Rail Kit RGS34-0- Ten grounding strips; 78.70" (2m) length;.67" (7mm) width;.05" (.27mm) thickness; provided with.6 oz. (5cc) of antioxidant, ten grounding stickers, 30 cage nut bonding studs, 80 #2-24 bonding nuts and 30 strip clips. Grounding usbar Kits Provide the common grounding point within the cabinet Optimized for installation on 9" racks or cabinets that meet EIA-30-D Can be positioned anywhere on the rack or cabinet Available pre-assembled with twenty mounting screws for quick and easy installation Engineered to comply with US and International grounding requirements RGR9U Part Description Grounding usbar Kits for Threaded Rail Fasteners RGR9Y Grounding busbar; 9" (483mm) length; tin-plated; fourteen holes arranged for flexibility in mounting; provided with two each #2-24 x /2" and M6 x 2mm thread-forming screws. RGR9U Grounding busbar; 9" (483mm) length; tin-plated; twenty holes arranged for flexibility in mounting with twenty #2-24 x /2" hex head screws installed; mounting hole sets have 5/8" (5.9mm) spacing; provided with two each #2-24 x /2", M6 x 2mm thread-forming screws, and two #2 flat washers for mounting. Grounding usbar Kit for Cage Nut Rail Fasteners RGR9CN Grounding busbar; 9" (483mm) length; tin-plated; twenty holes arranged for flexibility in mounting with twenty #2-24 x /2" hex head screws installed; mounting hole sets have 5/8" (5.9mm) spacing; provided with two cage nut bonding studs and four #2-24 bonding nuts. For service and technical support, call (outside the U.S. and Canada, see back c). 7

18 A. PHYSICAL INFRASTRUCTURE SOLUTIONS Front to ack Rail Jumper Kits ond the front and back cabinet rails to the cabinet grounding busbar Patent pending hardware incorporates paint piercing serrations to create a bond point between the cabinet rail and lug; hardware never needs to be removed for new equipment installations Length In. (m) oth ends are factory terminated with reverse bent lugs that save space, confining the connection to one RU Available in three lengths, 20", 30", and 40" to satisfy a wide range of cabinet rail depths Engineered to comply with US and International grounding requirements Part Description Front to ack Rail Jumper Kits for #2-24 or M6 Rail Fasteners CGJ620U 20 (.) CGJ630U 30 (.75) CGJ640U 40 (.00) Two #6 (6mm²) jumpers; factory terminated on both ends with 90 reverse bent lugs; provided with.6 oz. (5cc) of antioxidant, two grounding stickers, eight each #2-24 and M6 bonding studs and sixteen each #2-24 and M6 bonding nuts. Front to ack Rail Jumper Kits for Cage Nut Rail Fasteners CGJ620U 20 (.) CGJ630U 30 (.75) CGJ640U 40 (.00) Two #6 (6mm²) jumpers; factory terminated on both ends with 90 reverse bent lugs; provided with.6 oz. (5cc) of antioxidant, two grounding stickers, eight cage nut bonding studs and 24 #2-24 bonding nuts. 8 Order number of pieces required, in multiples of Standard Package Quantity. Prime items appear in OL

19 Equipment Jumper Kits ond network equipment to grounding strip or grounding busbar Jumper kit available with both ends factory terminated to provide a bolt-on solution Jumper kit available with one end factory terminated to attach to the grounding strip or grounding busbar; free end accommodates unique equipment terminations Use jumpers with 90 bent lug, on grounding strip side, for high density grounding requirements up to one ground point per RU RGEJ024PFY RGEJ057PFY Use jumpers with 45 bent lugs, on grounding strip side, for improved cable management Use 24" jumpers when network equipment ground point is located near the grounding strip side of the rack or cabinet Use 36" jumpers when network equipment ground point is located away from the grounding strip side of the rack Engineered to comply with US and International grounding requirements Length In. (m) Angle Part Description Ctn. #6 (6mm²) Equipment Jumper Factory Terminated on One End for Switches, and 4-Post Racks GJS660U 60 Straight #6 green wire with yellow horizontal stripe. 0 GJS696U (.52) 96 (2.44) Straight Jumper is pre-terminated on one end with LCC6-4JAW- 0 #0 (6mm²) Equipment Jumpers Factory Terminated on oth Ends RGEJ024PHY 24 (.6) 45 #0 (6mm²) jumper; bent lug on grounding strip side to straight lug on equipment; provided 0 RGEJ024PFY with.6 oz. (5cc) of antioxidant and two each 0 (.6) #2-24 x /2", M6 x 2mm, #0-32 x /2" and RGEJ036PFY M5 x 2mm thread-forming screws. 0 (.9) #6 (6mm²) Equipment Jumpers Factory Terminated on oth Ends RGEJ624PHY 24 (.6) 45 #6 (6mm²) jumper; bent lug on grounding strip side to straight lug on equipment; provided 0 RGEJ624PFY with.6 oz. (5cc) of antioxidant and two each 0 (.6) #2-24 x /2", M6 x 2mm, #0-32 x /2" and RGEJ636PFY M5 x 2mm thread-forming screws. 0 (.9) #0 (6mm²) Equipment Jumper Factory Terminated on One End RGEJ057PFY 57 (.45) 90 #0 (6mm²) jumper; bent lug on grounding strip side; provided with.6 oz. (5cc) of antioxidant and two each #2-24 x /2", M6 x 2mm, #0-32 x /2" and M5 x 2mm thread-forming screws. #6 (6mm²) Equipment Jumper Factory Terminated on One End RGEJ657PFY 57 (.45) 90 #6 (6mm²) jumper; bent lug on grounding strip side; provided with.6 oz. (5cc) of antioxidant and two each #2-24 x /2", M6 x 2mm, #0-32 x /2" and M5 x 2mm thread-forming screws. An equal number of M6 x 2mm thread-forming screws also provided in each kit. How to Select the Appropriate Equipment Jumper 0 0 A. 3" (76mm) or larger 3" (76mm) or smaller Select 24" equipment jumpers with 90 lugs when equipment grounding connection is close to the grounding strip. Select 36" equipment jumpers with 90 lugs when equipment grounding connection is on the opposite side from the grounding strip. Select equipment jumpers with 45 lugs for lower density applications or shallow depth equipment to provide improved cable management. For service and technical support, call (outside the U.S. and Canada, see back c). 9

20 A. PHYSICAL INFRASTRUCTURE SOLUTIONS Surge Suppressor Jumper Kit onds power or data line surge suppressor to grounding strip or grounding busbar oth ends factory terminated to provide a bolt-on solution SSGK- Engineered to comply with US and International grounding requirements Part Description #0 (6mm²) jumper; 24" (.6m) length; factory terminated on both ends; one-hole lug on surge suppressor to two-hole lug on grounding strip/busbar side; provided with.6 oz. (5cc) of antioxidant and two each #2-24 x /2", M6 x 2mm, #0-32 x /2" and M5 x 2mm thread-forming screws. Armored Grounding Kit Provides a secure bond to the armor sheath on indoor and indoor/outdoor fiber optic cables at both cassette and enclosure ends Worm-gear design evenly distributes forces across the armor Made from steel and aluminum material is compatible with common armor for long term reliability lack insulating c protects and hides the connection for an aesthetically pleasing work area Complies with industry requirements ensuring a high level of reliability and safety Part Description ACG24K Crimped jumper wire assembly; 24" (609.6mm) length; LCC6-4, #0 mechanical clamp; provided with two each #2-24, M6 slotted hex head zinc-plated thread-forming screws, and black polypropylene terminal c. 20 Order number of pieces required, in multiples of Standard Package Quantity. Prime items appear in OL

21 Telecommunication Equipment Conductor (TEC) Kits onds the rack or cabinet to the (TG) Jumper kit available with both ends factory terminated to provide a bolt-on solution Jumper kit available with one end factory terminated to attach to the rack or cabinet; free end accommodates unique length requirements Engineered to comply with US and international grounding requirements A. Length In. (mm) Angle Part Description Pre-Terminated on oth Ends Jumpers Pre-Terminated on oth Ends GJ672UH Straight and 45 One 72" length #6 green wire with yellow horizontal stripe. Jumper is pre-terminated on one end with LCC6-4JAWH-L and the other end with LCC6-4JAW- GJ696UH Straight and 45 One 96" length #6 green wire with yellow horizontal stripe. Jumper is pre-terminated on one end with LCC6-4JAWH-L and the other end with LCC6-4JAW- GJ620UH Straight and 45 One 20" length #6 green wire with yellow horizontal stripe. Jumper is pre-terminated on one end with LCC6-4JAWH-L and the other end with LCC6-4JAW- GJ644UH Straight and 45 GJ668UH Straight and 45 GJ692UH Straight and 45 GJ626UH Straight and 45 GJ6240UH Straight and 45 One 44" length #6 green wire with yellow horizontal stripe. Jumper is pre-terminated on one end with LCC6-4JAWH-L and the other end with LCC6-4JAW- One 68" length #6 green wire with yellow horizontal stripe. Jumper is pre-terminated on one end with LCC6-4JAWH-L and the other end with LCC6-4JAW- One 92" length #6 green wire with yellow horizontal stripe. Jumper is pre-terminated on one end with LCC6-4JAWH-L and the other end with LCC6-4JAW- One 26" length #6 green wire with yellow horizontal stripe. Jumper is pre-terminated on one end with LCC6-4JAWH-L and the other end with LCC6-4JAW- One 240" length #6 green wire with yellow horizontal stripe. Jumper is pre-terminated on one end with LCC6-4JAWH-L and the other end with LCC6-4JAW- GJ6264UH Straight and 45 One 264" length #6 green wire with yellow horizontal stripe. Jumper is pre-terminated on one end with LCC6-4JAWH-L and the other end with LCC6-4JAW- GJ6288UH Straight and 45 One 288" length #6 green wire with yellow horizontal stripe. Jumper is pre-terminated on one end with LCC6-4JAWH-L and the other end with LCC6-4JAW- Table continues on page 22 For service and technical support, call (outside the U.S. and Canada, see back c). 2

22 A. PHYSICAL INFRASTRUCTURE SOLUTIONS Telecommunication Equipment Conductor (TEC) Kits (continued) Pre-Terminated on One End Length In. (mm) Angle Part Description Jumpers Pre-Terminated on One End GJS620U Straight One 20" length #6 green wire with yellow horizontal stripe. Jumper is pre-terminated on one end with LCC6-4JAW- GJS680U Straight One 80" length #6 green wire with yellow horizontal stripe. Jumper is pre-terminated on one end with LCC6-4JAW- Hardware for TEC Kits Part Description Hardware for TEC Kits HDW/4-KT HDW3/8-KT HDW/4-A-KT HDW3/8-A-KT Stainless steel mounting hardware for busbar; two /4-20 hex bolts, two /4-20 hex nuts, four /4 flat washers and two /4 elleville compression washers. Mounting hardware for rack or cabinet; two #2-24 thread-forming screws and two M6 thread-forming screws. Stainless steel mounting hardware for busbar; two 3/8-6 hex bolts, two 3/8-6 hex nuts, four 3/8 flat washers and two 3/8 elleville compression washers. Mounting hardware for rack or cabinet; two #2-24 thread-forming screws and two M6 thread-forming screws. Stainless steel mounting hardware for busbar; two /4-20 hex bolts, two /4-20 hex nuts, four /4 flat washers and two /4 elleville compression washers. Mounting hardware for rack or cabinet; two #0-32 thread-forming screws and two M5 thread-forming screws. Stainless steel mounting hardware for busbar; two 3/8-6 hex bolts, two 3/8-6 hex nuts, four 3/8 flat washers and two 3/8 elleville compression washers. Mounting hardware for rack or cabinet; two #0-32 thread-forming screws and two M5 thread-forming screws. 22 Order number of pieces required, in multiples of Standard Package Quantity. Prime items appear in OL

23 A. Enclosure Grounding Kit Provides equipotential bonding and protection from static electricity for equipment housed in enclosures A discrete grounding point for each piece of equipment within the enclosure allows equipment to be easily added or moved without disturbing other grounding connections Anti-rotation design prevents one-hole lugs from loosening Grounding washer provides a high performance electrical bond, eliminating the need to manually remove paint uilt-in ESD port provides a convenient docking station for ESD wrist strap Provides proper bonding of PANZONE Active Wall Mount Enclosure PZAEWM3, see page 5 PZAEGK Part Description One tin-plated copper bracket; 3.92" L x.56" W x.79" H (99.6mm x 4.2mm x 20.mm); provided with four #2-24 screws, one each #0-32 and #0-24 hex nut, #0 split lock washer, grounding washer and ESD protection sticker. Shielded Jack Module Grounding Kit Alternate method for grounding modules to another grounding wire in shielded applications CJSGK-XY Part Description Kit used to ground enhanced GIGA-TX Style Shielded Jack Modules to another ground wire in shielded applications. Ctn For service and technical support, call (outside the U.S. and Canada, see back c). 23

24 A. PHYSICAL INFRASTRUCTURE SOLUTIONS Electrostatic Discharge (ESD) Port Kits and Wrist Strap Accommodate standard ESD wrist strap 4mm plug Wrist strap provides rapid and continuous drain of electrostatic charge between a person and the surface that the wrist strap is bonded to, thus preventing damaging static discharge into equipment Can be mounted to front or back of rack or cabinet for convenient access ent 45, acts as a hook to hold wrist strap Two-hole configuration provides anti-rotation and prevents loss of bond arrel permanently marked with the protective earth (ground) symbol Engineered to comply with US and International grounding requirements RGESD2- RGESD2- Part Description ESD Port Kit for #2-24 or M6 Rail Fasteners RGESD2- Two-hole ESD port with 5/8" hole spacing; provided with an ESD protection sticker,.6 oz. (5cc) of antioxidant, and two each #2-24 x /2" and M6 x 2mm thread-forming screws. ESD Port Kit for Cage Nut Rail Fasteners RGESD2- Two-hole ESD port with 5/8" hole spacing; provided with an ESD protection sticker,.6 oz. (5cc) of antioxidant, two cage nut bonding studs and two #2-24 bonding nuts. ESD Wrist Strap RGESDWS Adjustable fabric ESD wrist strap with 6' coil cord, banana plug, megohm resistor and 4mm snap. ESD port must be attached to a grounded member. ESD wrist strap sold separately. Ctn RGESDWS 24 Order number of pieces required, in multiples of Standard Package Quantity. Prime items appear in OL

25 A. Screws Patent pending screws create an electrical bond between painted patch panels and racks or cabinets Serrations on bottom of screw remove paint from patch panel, providing metal-to-metal contact Available in two color options to meet different application needs Thread-forming, provides a bond to the rack or cabinet by removing paint from threaded holes and minimizing metal shavings Permanently marked with the protective earth (ground) symbol and PANDUIT logo Easily installed with Phillips screwdriver Part Description RGTSG-C Green thread-forming bonding screw, #2-24 x /2". 00 RGTSM6G-C Green thread-forming bonding screw, M6 x 5mm. 00 RGTS032G-C Green thread-forming bonding screw, #0-32 x /2". 00 RGTSM5G-C Green thread-forming bonding screw, M5 x 5mm. 00 Cage Nut Creates an electrical bond between the mounting rails and equipment Conforms to EIA-30-D specifications for racks and cabinets CN4K Made from high carbon steel Easily installed with a Phillips, flat blade, or nut screwdriver Part Description Green bonding cage nut, #2-24 and green thread-forming grounding screw, #2-24 x /2". Thread-Forming Screws Thread-forming, provide a bond to the rack or cabinet by removing paint from threaded holes and minimizing metal shavings Easily installed with 5/6" (8mm) socket head wrench or flat blade screwdriver Part Description RGTS-CY Thread-forming grounding screw, #2-24 x /2". 00 RGTSM6-C Thread-forming grounding screw, M6 x 2mm. 00 RGTS032-C Thread-forming grounding screw, #0-32 x /2". 00 RGTSM5-C Thread-forming grounding screw, M5 x 2mm For service and technical support, call (outside the U.S. and Canada, see back c). 25

26 A. Paint Piercing Grounding Washer Kit onds frame members on bolt-together racks No paint scraping required Green color-coding to indicate bonding application PHYSICAL INFRASTRUCTURE SOLUTIONS Engineered to comply with US and International grounding requirements Part Description RGW-00-Y 00 paint piercing bonding washers for 3/8" (M8) stud size;.875" (22.2mm) ; provided with.6 oz. (5cc) of antioxidant. Hardware Kits Patent pending bonding hardware kits incorporate paint piercing serrations to create a bond point between the rack or cabinet and painted patch panels, mounted equipment, servers, busbars and jumpers TRSK CGNSK Thread-forming, provide a bond to the rack or cabinet by removing paint from holes and minimizing metal shavings Green color-coding to indicate bonding application Part Description Stud Kits for Threaded Rail Fasteners TRSK stud kit for threaded #2-24 rail fasteners; includes 25 bonding studs and bonding nuts. TRSM6K stud kit for threaded M6 rail fasteners; includes 25 bonding studs and bonding nuts. Stud Kit for Cage Nut Rail Fasteners CGNSK stud kit for cage nut rail fasteners; includes 25 bonding studs and bonding nuts. Nuts GN-C nut for threaded #2-24, cage nut, and /4" thru-hole rail fasteners. 00 GNM6-C nut for threaded M6 rail fasteners. 00 GN 26 Order number of pieces required, in multiples of Standard Package Quantity. Prime items appear in OL

27 Retrofit Cabinet Grounding Kits Provide a dedicated ground system to maintain system performance and protect network equipment when equipment is already installed Patent pending hardware incorporates paint piercing serrations to create a bond point between the cabinet rail, grounding busbar and lug; hardware never needs to be removed for new equipment installations Optimized for installation on 9" cabinets that meet EIA-30-D, with functioning equipment, and are deployed in the field Provides a complete system of matched components to save cost and labor Engineered to comply with US and International grounding requirements A. Electrostatic Discharge (ESD) Port Kit RGESD (page 24) CGR630U Equipment Jumper Kit RGEJ (page 9) Common Network (CN) Jumper Kit RGCN (page 6) Retrofit Cabinet Grounding Kit CGR630 Part Description CGR630U Retrofit grounding kit for installation on cabinets with threaded #2-24 or M6 rail fasteners and rail depth up to 30" (.75m); includes one RGR9U grounding busbar kit and one CGJ630U front to back rail jumper kit. CGR630U Retrofit grounding kit for installation on cabinets with cage nut rail fasteners and rail depth up to 30" (.75m); includes one RGR9U grounding busbar kit and one CGJ630U front to back rail jumper kit. For service and technical support, call (outside the U.S. and Canada, see back c). 27

28 A. PHYSICAL INFRASTRUCTURE SOLUTIONS Retrofit Rack Grounding Kits Provide a dedicated ground system to maintain system performance and protect network equipment when equipment is already installed Optimized for installation on 9" racks that meet EIA-30-D, with functioning equipment, and are deployed in the field Provide a complete system of matched components that can be easily selected to save cost and labor Thread-forming screws eliminate the need to manually remove paint from the rack Engineered to comply with US and International grounding requirements Network Equipment Rack Grounding usbar RGR HTAP (page 37) Grounding Jumper RGREJ696Y Lug (see pages RGRKCNJEJY 33 36) Rack Grounding Kit RGRKCNJEJY usbar and Jumper Kits RGRKCNJEJY Grounding Jumper RGREJ696Y or RGREJ096Y RGRKCNJY usbar Kits RGR9Y RGR9U RGRKCNJY Part Description Rack grounding kit to ground the rack and one piece of equipment; includes one RGR9U busbar, one HTCT2-2- HTAP, and two RGREJ696Y grounding jumpers. Rack grounding kit to ground the rack; includes one RGR9U busbar, one HTCT2-2- HTAP, and one RGREJ696Y grounding jumper. Grounding busbar; 9" (483mm) length; tin-plated; fourteen holes arranged for flexibility in mounting; provided with two each #2-24 x /2" and M6 x 2mm thread-forming screws. Grounding busbar; 9" (483mm) length; tin-plated; twenty holes arranged for flexibility in mounting with twenty #2-24 x /2" hex head screws installed; mounting hole sets have 5/8" (5.9mm) spacing; provided with two each #2-24 x /2", M6 x 2mm thread-forming screws, and two #2 flat washers for mounting. Rack Grounding Kit RGRKCNJY RGR9CN Grounding busbar; 9" (483mm) length; tin-plated; twenty holes arranged for flexibility in mounting with twenty #2-24 x /2" hex head screws installed; mounting hole sets have 5/8" (5.9mm) spacing; provided with two bonding cage nuts and four #2-24 bonding screws. Equipment Jumper Kits RGREJ696Y Grounding jumper; #6 (6mm²); 96" (2.44m) length; one end factory terminated to lug; provided with.6 oz. (5cc) of antioxidant and two each #2-24 x /2", M6 x 2mm, #0-32 x /2" and M5 x 2mm thread-forming screws. RGREJ096Y Grounding jumper; #0 (6mm²); 96" (2.44m) length; one end factory terminated to lug; provided with.6 oz. (5cc) of antioxidant and two each #2-24 x /2", M6 x 2mm, #0-32 x /2" and M5 x 2mm thread-forming screws. 28 Order number of pieces required, in multiples of Standard Package Quantity. Prime items appear in OL

29 ICSI/J--607-A Telecommunications Grounding usbars Meet ICSI and J--607-A requirements for network systems grounding applications Made of high conductivity copper and tin-plated to inhibit corrosion TG TMG Come pre-assembled with brackets and insulators attached for quick installation Use PANDUIT component labels, sold separately, to identify busbars to meet TIA/EIA-606-A, see chart below Telecommunications Grounding and Conductor Label Kit ar Size Part Description No. of Mounting Positions /4" Stud Hole with 5/8" Hole Spacing 3/8" Stud Hole with " Hole Spacing Telecommunications Grounding usbars (TG) G20304TPI- /4" x 2" x 0" 4 3 G20306TPI- /4" x 2" x 2" 6 3 G2032TPI- /4" x 2" x 20" 2 3 G2034TPI- /4" x 2" x 24" 4 5 Telecommunications Main Grounding usbars (TMG) G4062TPI- /4" x 4" x 2" 2 6 G40624TPI- /4" x 4" x 20" 24 6 G40632TPI- /4" x 4" x 24" 28 0 LTYK Label kit includes printed tag and one flame retardant cable tie. For complete labeling solutions and product information, reference charts on pages 8. A. Component Labels for ICSI/J--607-A Telecommunications Grounding usbars Telecommunications Grounding usbar All G2 and G4 Parts Suggested Label Solutions for TIA/EIA-606-A Compliance Laser/Ink Jet Desktop Printer Label TDP43MY Thermal Transfer Desktop Printer Label PANTHER LS8E Hand-Held Printer Label COUGAR LS9 Hand-Held Printer Label C200X00FJJ C200X00YPT C200X00FJC T00X000VPC-K For service and technical support, call (outside the U.S. and Canada, see back c). 29

30 A. PHYSICAL INFRASTRUCTURE SOLUTIONS NEMA Hole Pattern Grounding usbars Provided with standard NEMA hole pattern spacing Made of high conductivity copper and tin-plated to inhibit corrosion Come pre-assembled with brackets and insulators attached for quick installation Insulators provide 600 V of insulation ar Size No. of Mounting Positions /2" Stud Hole with 3/4" Hole Spacing 7/6" Stud Hole with 5/8" Hole Spacing G4N0007TPI- /4" x 4" x 2" 7 G4N006TPI- /4" x 4" x 24" 6 G4N0024TPI- /4" x 4" x 36" G4N0026TPI- /4" x 4" x 48" 26 G4N0034TPI- /4" x 4" x 60" 34 Grounding usbar Inch Hole Spacings Provided with inch hole D pattern spacing Made of high conductivity copper and tin-plated to inhibit corrosion usbar Type ISCI G2..series NEMA See pages for Lug information Come pre-assembled with brackets and insulators attached for quick installation Insulators provide 600 V of insulation usbar Pattern D N ar Size No. of Mounting Positions /2" Stud Hole with 3/4" Hole Spacing 7/6" Stud Hole with " Hole Spacing G2D0008TPI- /4" x 2" x 2" 8 G2D002TPI- /4" x 2" x 24" 2 G2D0033TPI- /4" x 2" x 36" 33 G2D0044TPI- /4" x 2" x 48" 44 G2D0056TPI- /4" x 2" x 60" Order number of pieces required, in multiples of Standard Package Quantity. Prime items appear in OL

31 837 Universal eam Grounding Clamp Universal, fits on a wide range of standard (angled) and wide flange (parallel) structural steel beams Provide a mounting pad suitable for a two-hole compression lug Install quickly and easily with standard /4" key hex wrench tooling UL 467 Listed and CSA 22.2 Certified for grounding and bonding suitable for direct burial in earth or concrete Comply with vibration tests per MIL--202G (METHOD 20A) For the complete line of STRUCTUREDGROUND Direct urial Compression Grounding, visit A. Conductor Size (mm²) GUC0-6 #6 0 (6 240) Flange Thickness In. (mm) (6.3 7.) Hole Spacing (In.) Hole Spacing (mm) Thread size Figure Dimensions In. (mm) L W H / Auxiliary racket and Jumpers onds ladder rack sections together without drilling holes in the ladder rack Supports grounding conductors in the telecommunications room, allows separation of grounding conductors from other cables on the ladder rack Holds up to four conductors in sizes up to 7 kcmil onds all /2" and 2" ladder rack rails Paint piercing teeth provide electrical continuity between ladder rack members while minimizing debris Front and back mounting screw options allow easy installation and visual inspection GAC GACJ68U W GAC- Part Description Auxiliary cable bracket;.25" (3.8mm) width; 7.00" (77.8mm) height; 4.87" (23.7mm) depth; provided with one mounting screw. Ctn. 0 GACJ68U Auxiliary cable bracket jumper for bonding ladder rack sections; #6 (6mm²); 8.0" (203mm) length; factory terminated on both ends with straight, two-hole, long barrel compression lugs; provided with.6 oz. (5cc) of antioxidant and four mounting screws. H D GACJ62U Auxiliary cable bracket jumper for bonding ladder rack sections; #6 (6mm²); 2.0" (305mm) length; factory terminated on both ends with straight, two-hole, long barrel compression lugs; provided with.6 oz. (5cc) of antioxidant and four mounting screws. GACJ68U Auxiliary cable bracket jumper for bonding ladder rack sections; #6 (6mm²); 8.0" (457mm) length; factory terminated on both ends with straight, two-hole, long barrel compression lugs; provided with.6 oz. (5cc) of antioxidant and four mounting screws. For service and technical support, call (outside the U.S. and Canada, see back c). 3

32 A. Ring Terminal, Vinyl Expanded Insulation Expanded wire entry designed to accommodate wire with a larger insulation thickness Ring tongue design assures a secure connection in high vibration applications Insulation support helps to prevent wire damage in bending applications razed seam protects terminal barrel from splitting during the crimp process C L W UL Flammability UL 94V-0, maximum insulation temperature 22 F (05 C) Internal barrel serrations assure good wire contact and maximum tensile strength UL and CSA rated up 600 V per UL 486 Figure Dimensions (In.) PANDUIT Crimping Tool ** Wire Range Color Code Stock Thickness Max. Ins. Stud Size L W C PV4-6RX-C # CT-00A, 00 0 PV4-8RX-C CT-600-A, # lue CT-5, PV4-0RX-C # CT-55, PV4-4RX-C /4" CT PV0-6RX-L.04.2 # CT-00A, 0 PV0-8RX-L CT-600-A, 2 0 Yellow.04.2 # CT-5, PV0-0RX-L.04.2 # CT-55, PV0-4RX-L.04.2 /4" CT-20 0 UL and CSA approved tooling/product combinations. For crimping tool information, see pages 42 and 43. **To order in bulk, replace -C in the part number with -M for a bulk package of 000 and replace -L with -D for a bulk package of 0. Metric Ring Terminal, Vinyl Insulated Funnel Entry Insulation support helps to prevent wire damage in bending applications razed seam protects terminal barrel from splitting during the crimp process C L W Wire Range Color Code For crimping tool information, see page 43. UL Flammability UL94V-0, maximum insulation temperature 22 F (05 C) Internal barrel serrations assure good wire contact and maximum tensile strength Max. Ins. Stud Size Figure Dimensions (mm) L W C PANDUIT Crimping Tool Ctn. Ctn. PMV-5R-CY 4.0 M CT-5, Red PMV-6R-CY 4.0 M CT PMV2-5R-C 4.70 M CT-5, lue PMV2-6R-C 4.70 M CT PMV6-5R-L 6.0 M PMV6-6R-L CT-5, Yellow 6.0 M CT-20 PMV6-8R-L 6.0 M Order number of pieces required, in multiples of Standard Package Quantity. Prime items appear in OL

33 With Code Conductor, Two-Hole, Long arrel with Window Lug For Use with Stranded Conductors W HOLE SPACING L INSPECTION WINDOW Meets J--607-A requirements for network systems grounding applications Tested by Telcordia meets NES Level 3 with conductor Requires crimping tools and dies, see pages UL Listed and CSA Certified with conductor for use up to 35 KV** and temperature rated 90 C when crimped with PANDUIT and specified competitor crimping tools and dies W HOLE SPACING INSPECTION WINDOW 45 W HOLE SPACING Color-coded barrels marked with PANDUIT and specified competitor die index numbers for proper crimp die selection Long barrel maximizes number of crimps and provides premium wire pull-out strength and electrical performance Inspection window to visually assure full conductor insertion Tin-plated to inhibit corrosion Available with NEMA hole sizes and spacing 90 INSPECTION WINDOW A. Figure : Straight Figure 2: 45 ent L L Figure 3: 90 ent W HOLE SPACING L INSPECTION WINDOW W HOLE SPACING INSPECTION WINDOW L 45 W HOLE SPACING 90 INSPECTION WINDOW Figure 4: Slotted, Straight Figure No. LCC0-4JAW-L* 4 #4 #0 /4 STR, (M6) LCC0-4JAWH-L* 5 #2 #0 /4 SOL (M6) (2.5 LCC0-4JAWF-L* 6 /4 6mm² (M6) STR, 4 LCC0-4AW-L* 6mm² /4 SOL) (M6) LCC8-0AW-L See pages 46 and 47 for PANDUIT and competitor tool and die information. *Not tested to NES Level 3 requirements. **Consult cable manufacturer for voltage stress relief instructions with applications greater than 2000 V. ^See page 30 for busbar patterns. NEMA hole sizes and spacing. Conductor Size Figure 5: Slotted, 45 ent Stud Hole Size In. (mm) #0 (M4) LCC8-4AWH-L 2 /4 LCC8-4AWF-L 3 #8 (0mm²) (M6) /4 (M6) LCC8-38DW-L 3/8 (M8) Stud Hole Spacing In. (mm)..63 ( )..63 ( )..63 ( ).63 (6.0).63 (6.0).63 (6.0).63 (6.0).00 (25.4) L Figure 6: Slotted, 90 ent Figure Dimensions In. (mm) W L.42 (0.7).42 (0.7).42 (0.7).42 (0.7).4 (0.4).48 (2.2).48 (2.2).60 (5.2).53 (3.5).53 (3.5).53 (3.5).53 (3.5).70 (7.8).70 (7.8).70 (7.8).70 (7.8) PANDUIT Crimping Tool PANDUIT Die Color and Die No. Wire Strip Length In. (mm) usbar Pattern^.93 (49.0).78 (45.2) CT-00A, 9/6.56 CT-570 (4) (39.6).93 (49.0) 2.0 (5.3).9 CT-700, (48.5) CT-930, 3/4 CT-293, Red P2.6 (9) CT- (40.9) 293/E 2.70 (68.6), D Table continues on page 34 For service and technical support, call (outside the U.S. and Canada, see back c). 33

34 A. With LCC6-0AW-L 4 Code Conductor, Two-Hole, Long arrel with Window Lug (continued) Figure Conductor No. Size Stud Hole Size In. (mm) #0 (M4) LCC6-4JAW-L 4 /4 (M6) LCC6-4JAWH-L 5 /4 (M6) LCC6-4JAWF-L 6 #6 (6mm²) /4 (M6) LCC6-4AW-L /4 (M6) LCC6-38DW-L 3/8 (M8) LCC6-2W-L /2 (M2) LCC4-4AW-L /4 (M6) #4 #3 LCC4-38DW-L STR, 3/8 #2 (M8) SOL (25mm² LCC4-2W-L STR) /2 (M2) LCC2-4AW-Q /4 (M6) LCC2-38DW-Q #2 3/8 (35mm²) (M8) LCC2-2W-Q /2 (M2) LCC/0-4AW-X /4 (M6) LCC/0-38DW-X /0 3/8 (mm²) (M8) LCC/0-2W-X /2 (M2) LCC2/0-4AW-X /4 (M6) LCC2/0-38DW-X 2/0 3/8 (70mm²) (M8) LCC2/0-2W-X /2 (M2) LCC3/0-38DW-X 3/8 3/0 (M8) LCC3/0-2W-X (95mm²) /2 (M2) LCC4/0-38DW-X 3/8 4/0 (M8) LCC4/0-2W-X (95mm²) /2 (M2) LCC2-38DW-X 3/8 2 kcmil (M8) LCC2-2W-X (20mm²) /2 (M2) Stud Hole Spacing In. (mm) (6.0 9.)..63 ( )..63 ( )..63 ( ).63 (6.0).00 (25.4).75 (44.5).63 (6).00 (25.4).75 (44.5).63 (6.0).00 (25.4).75 (44.5).63 (6.0).00 (25.4).75 (44.5).63 (6.0).00 (25.4).75 (44.5).00 (25.4).75 (44.5).00 (25.4).75 (44.5).00 (25.4).75 (44.5) Figure Dimensions In. (mm) See pages 46 and 47 for PANDUIT and competitor tool and die information. *Not tested to NES Level 3 requirements. **Consult cable manufacturer for voltage stress relief instructions with applications greater than 2000 V. ^See page 30 for busbar patterns. NEMA hole sizes and spacing. W.46 (.7).48 (2.2).48 (2.2).48 (2.2).48 (2.2).62 (5.7).75 (9.0).55 (4.0).62 (5.7).75 (9.).60 (5.2).66 (6.8).75 (9.).76 (9.3).76 (9.3).80 (20.3).85 (2.6).85 (2.6).85 (2.6).96 (24.4).96 (24.4).06 (26.9).96 (24.4).7 (29.7).7 (29.7).07 (27.2).07 (27.2).07 (27.2).07 (27.2).07 (27.2).07 (27.2).3 (28.7).05 (26.7).05 (26.7).3 (28.7).6 (29.5).6 (29.5).6 (29.5).44 (36.6).44 (36.6).44 (36.6). (38.). (38.). (38.). (38.). (38.).56 (39.6).56 (39.6).6 (40.9).6 (40.9) L 2.52 (64.0) PANDUIT Crimping Tool PANDUIT Die Color and Die No. Wire Strip Length In. (mm) usbar Pattern^ 2.49 (63.2) 3.08 (78.2), D 5.00 (27.0) 2. (63.5) 3/6 (30) N 2.08 (52.8) CT-700, /8.66 CT-930, lue (29) (42.2) CT-293, P24 CT /E (63.2) CT-700, / CT-930, (29) (78.5) Gray CT-293,, D P29 CT /E (28.5) 3/6 N (30) 2.67 (67.8) CT-700, 3.24 CT-930, rown /4 (82.3) CT-293,, D P33 (32) CT /E (2.0) N 3.07 (78.0) CT-930, 3.57 CT-293, Pink /2 (90.7), D CT- P42 (38) /E (20.4) N 3.23 (82.0) CT-930, 3.67 CT-293, lack 9/6 (93.2), D CT- P45 (40) /E (22.7) N 3.70 CT-930, (94.0) CT-293, Orange 9/6, D 4.87 CT- P (40) (23.7) 293/E N 3.8 CT-930, (96.8) CT-293, Purple 5/8 N 3.8 CT- P54 (4) (96.8) 293/E N 3.89 CT-930, (98.8) CT-293, Yellow /6, D 4.2 CT- P62 (43) (04.6) 293/E N Prime items appear in OL

35 T W With HOLE SPACING L INSPECTION WINDOW Figure : Straight Flex Conductor, Two-Hole, Long arrel with Window Lug For Use with Flexible, Extra-Flexible, and Code Stranded Conductors Meets J--607-A requirements for network systems grounding applications Requires crimping tools and dies, see pages UL Listed and CSA Certified with conductor for use up to 35 KV** and temperature rated 90 C when crimped with PANDUIT and specified competitor crimping tools and dies Color-coded barrels marked with PANDUIT and specified competitor die index numbers for proper crimp die selection T W HOLE SPACING INSPECTION WINDOW Figure 2: 45 ent L 45 T W Can be used with code conductor and flex conductor class: G,H,I,K,M and Diesel Locomotive Long barrel maximizes number of crimps and provides premium wire pull-out strength and electrical performance Inspection window to visually assure full conductor insertion Generously beveled wire entry prevents bent back strands when inserting conductor into barrel Tin-plated to inhibit corrosion Available with NEMA hole sizes and spacing HOLE SPACING 90 L Figure 3: 90 ent INSPECTION WINDOW A. Fig. No. LCCX8-4A-L Class G,H, I, K, M Flex Conductor Size Diesel Locomotive LCCX8-4AH-L 2 /4 (M6) #8 #8 #8 0mm² LCCX8-4AF-L 3 (0mm²) /4 (M6) Figure Dimensions In. (mm) Flex Metric Code Conductor Size Stud Hole Size In. (mm) Stud Hole Spacing In. (mm) W L /4 (M6) LCCX8-38D-L 3/8 (M8) LCCX6-4A-L /4 (M6) LCCX6-4AH-L 2 /4 (M6) #6 #6 #6 6mm² LCCX6-4AF-L 3 (6mm²) /4 (M6) LCCX6-38D-L 3/8 (M8).63 (6.0).63 (6.0).63 (6.0).00 (25.4).63 (6.0).63 (6.0).63 (6.0).00 (25.4).48 (2.2).48 (2.2).48 (2.2).60 (5.2).48 (2.2).48 (2.2).48 (2.2).62 (5.7).70 (7.8).70 (7.8).70 (7.8).70 (7.8).07 (27.2).07 (27.2).07 (27.2).07 (27.2) See pages 48 and 49 for PANDUIT and competitor tool and die information. **Consult cable manufacturer for voltage stress relief instructions with applications greater than 2000 V. ^See page 30 for busbar patterns. NEMA hole sizes and spacing. 2.0 (53.3).9 (48.5).62 (4.2) PANDUIT Crimping Tool CT-700, CT-930, CT-293, CT-293/E PANDUIT Die Color and Die No. Red P2 Wire Strip Length In. (mm) 3/4 (9) usbar Pattern^ 2.70 (68.6), D 2.49 (63.3) 2.8 (55.4).66 (42.2) CT-700, CT-930, CT-293, CT-293/E lue P24 /8 (29) 3.08 (78.2), D Table continues on page 36 For service and technical support, call (outside the U.S. and Canada, see back c). 35

36 A. With LCCX4/0-38D-X 4/0 (20mm²) 4/0 4/0 20mm² LCCX4/0-2-X 4/0 (95mm²) Flex Conductor, Two-Hole, Long arrel with Window Lug (continued) Fig. No. LCCX4-4A-L Class G,H, I, K, M Flex Conductor Size Diesel Locomotive Flex Metric Code Conductor Size Stud Hole Size In. (mm) /4 (M6) #4 #5, #4, #3 #4 25mm² LCCX4-38D-L (25mm²) 3/8 (M8) LCCX2-4A-E /4 (M6) LCCX2-38D-E #2 #2 3/8 #2 35mm² (35mm²) (M8) LCCX2-2-E /2 (M2) LCCX/0-4A-X /4 (M6) LCCX/0-38D-X /0 /0 mm² /0 3/8 (mm²) (M8) LCCX/0-2-X /2 (M2) LCCX2/0-4A-X LCCX2/0-38D-X 2/0 2/0 70mm² 2/0 3/8 (70mm²) (M8) LCCX2/0-2-X /2 (M2) LCCX3/0-38D-X 3/0 LCCX2-38D-X 2 kcmil 3/0 95mm² 3/0 (95mm²) /4 (M6) 3/8 (M8) 3/8 (M8) /2 (M2) kcmil 3/8 (M8) Stud Hole Spacing In. (mm).63 (6.0).00 (25.4).63 (6.0).00 (25.4).75 (44.5).63 (6.0).00 (25.4).75 (44.5).63 (6.0).00 (25.4).75 (25.4).00 (25.4).00 (25.4).75 (44.5).00 (25.4) Figure Dimensions In. (mm) W.55 (4.0).62 (5.7).70 (7.8).70 (7.8).75 (9.).85 (2.6).85 (2.6).85 (2.6).96 (24.4).96 (24.4).96 (24.4).06 (26.9).9 (30.2).9 (30.2).28 (32.5).05 (26.7).05 (26.7).36 (34.5).36 (34.5).36 (34.5). (38.). (38.). (38.). (38.). (38.). (38.).56 (39.6) 2.24 (56.9) 2.24 (56.9) 2.24 (56.9) See pages 48 and 49 for PANDUIT and competitor tool and die information. **Consult cable manufacturer for voltage stress relief instructions with applications greater than 2000 V. ^See page 30 for busbar patterns. NEMA hole sizes and spacing. L PANDUIT Crimping Tool PANDUIT Die Color and Die No. Wire Strip Length In. (mm) usbar Pattern^ 2.49 (63.3) CT-700, CT-930, /8 Gray P CT-293, (29) (78.5) CT-293/E, D 2.89 (73.4) 3.46 (87.9) CT-700, CT-930, CT-293, CT-293/E rown P33 7/6 (37), D 4.63 (7.6) N 3.23 (82.0) 3.67 CT-930, (93.2) CT-293, Pink P42 9/6, D (40) CT-293/E 4.83 (22.7) N 3.27 (83.) 3.70 CT-930, lack 9/6 (94.0) CT-293,, D P45 (40) CT-293/E 4.87 (23.7) N 3.8 (96.8) CT-930, CT-293, CT-293/E Orange P 5/8 (4), D 4.55 (5.6) CT-930,, D Purple 2 5/6 CT-293, 5.73 P54 (59) CT-293/E (45.5) N 4.59 (6.6) CT-930, CT-293, CT-293/E Yellow P62 2 5/6 (59), D Prime items appear in OL

37 HTAP Code/Flex Conductor HTAP RUN TAP Used to tap into continuous conductors as a splice or pigtailing Each HTAP terminates a wide range of conductor sizes and combinations of code and flex conductors Class G, H, I and Locomotive to suit a variety of applications Slotted design allows quick and easy assembly of conductor to HTAP using three PANDUIT 94V-0 cable ties included Tap grooves are separated from one another allowing them to function independently so HTAP can be used with a single or multiple taps providing maximum design and installation flexibility Color coded and marked with PANDUIT die index numbers for proper crimp die selection Requires crimping tools and dies, see pages UL Listed and CSA Certified with conductor for applications up to 600 V when crimped with PANDUIT and specified competitor crimping tools and PANDUIT crimping dies Tin plated to inhibit corrosion A. RUN W L RUN W L RUN W L RUN W L H TAP HTCT6-6- HTCT2-2- HTCT2-2- HTCT2-2- Conductor Size Range See page 52 for PANDUIT and competitor tool and die information. Figure Dimensions In. (mm) Wire Strand Type Run Tap Tap 2 Tap 3 L W H Code Flex Code Flex Code Flex Code Flex H TAP 2 TAP #6 #0 (0 6mm 2 ) #6 #0 (0 6mm 2 ) #2 #6 STR/SOL (25 6mm 2 ) #2 #8 (25 0mm 2 ) 2 kcmil #2 (20 35mm 2 ) 4/0 #2 (95 35mm 2 ) 2 kcmil #2 (20 35mm 2 ) 4/0 #2 (95 35mm 2 ) TAP 3 #6 #4 (0 2.5mm 2 ) #6 #4 (0 2.5mm 2 ) #2 #6 STR/SOL (25 6mm 2 ) #2 #8 (25 0mm 2 ) #2 #6 STR/SOL (25 6mm 2 ) #2 #8 (25 0mm 2 ) 2 kcmil #2 (20 35mm 2 ) 4/0 #2 (95 35mm 2 ) #8 #4 (6 2.5mm 2 ) #8 #4 (6 2.5mm 2 ) #8 #4 (6 2.5mm 2 ) #8 #4 (6 2.5mm 2 ) H TAP TAP 2 TAP HTCT6-6 HTCT2-2 HTCT2-2 HTCT2-2 #8 #4 (6 2.5mm 2 ) #8 #4 (6 2.5mm 2 ).6 (5.5).76 (9.3).92 (23.4).90 (22.9).40 (0.2).6 (5.5).96 (24.4).89 (22.6).99 (25.).55 (39.4).92 (48.8).92 (48.8) PANDUIT Crimping Tool CT-930, CT-293, CT- 293/E CT-930, CT-293, CT- 293/E CT-930, CT-293, CT- 293/E CT-930, CT-293, CT- 293/E H PANDUIT Die Color and Die No. Orange PH6 rown PH2 Purple PH25 Purple PH25 Wire Strip Length In. (mm) /6 (8) 3/6 (2) (25) (25) For service and technical support, call (outside the U.S. and Canada, see back c). 37

38 A. Clear Cs for HTCT HTAPs Made of high impact plastic to provide high impact strength and 360 inspections of crimped connection to assure the crimp is complete and the correct die was used Incorporate dual self-latching spring loaded latches and supplied with two PANDUIT UL 94V-0 cable ties to allow for easy snap-on assembly and ensure cs are secured Low profile design minimizes space requirements Each c half supports installation information labels inside plastic retainer strips to allow labels to be viewed on either side of c and to protect labels from being removed Incorporate molded in flash barriers which encompass the HTAP installation providing protection against electrical flash UL 94V-0 flame rating and oxygen index of 28 providing self-extinguishing, flame retardant properties Part number, voltage rating, temperature rating and HTCT part number molded into c for easy identification Flexible fingers located at each end of c prevent foreign objects from entering c and are made from ductile plastic material that allows easy installation and will not damage conductor insulation Use With HTAP Figure Dimensions In. (mm) L W H CLRCVR- HTCT (3.8) (35.8) (30.5) CLRCVR2- HTCT (29.5) (42.2) (35.6) CLRCVR3- HTCT2-2, HTCT (35.9) (54.9) (35.6) Labels for clear cs are sold separately and are printed with the PANDUIT LS8E Printer, see page 2. H L W Shown Assembled Code/Flex Conductor HTAP Kits HTAP Part No. Components Clear C Part No. HTWC6-6- HTCT6-6- CLRCVR- HTWC2-2- HTCT2-2- CLRCVR2- HTWC2-2- HTCT2-2- CLRCVR3- HTWC2-2- HTCT2-2- CLRCVR3-38 Order number of pieces required, in multiples of Standard Package Quantity. Prime items appear in OL

39 T Code Conductor, Thin Wall, Tin-Plated, CTAPF L For copper-to-copper tapping splicing or pigtailing Wide wire range-taking capability minimizes inventory requirements Color-coded for proper crimp die selection Ribbed design provides high strength Made from high conductivity wrought copper Tin-plated to inhibit corrosion and oxidation UL Listed and CSA Certified with conductor to 600 V and temperature rated to 90 C when crimped with PANDUIT and specified competitor crimping tools and dies A. V Q CTAPF4-2TP-C #6, #5, #4 (6 STR 25 STR) CTAPF/0-2TP-L #2, #, #/0 (25 35 STR STR 4 25 STR) CTAPF2/0-2TP-Q #, #/0, #2/0 ( STR 70 STR 70 STR) Figure Dimensions Conductor Size In. (mm) Run (mm 2 ) Tap (mm 2 ) Number of Ribs L T V Q #8 #6, #2 #8 (0 6 STR 4 0 STR) #4 #2, #4 #3, #2 #4 (25 35 STR STR 4 25 STR) #2 #, #3 #2, #2 #3 (35 STR 35 STR 4 35 STR) (3.8).82 (46.2).82 (46.2).07 (.8).09 (2.3).09 (2.3).40 (0.2).63 (6.0).7 (8.0).28 (7.).42 (0.7).48 (2.2) PANDUIT Crimping Tool CT-700, CT-930, CT-293 CT-930, CT-293 CT-930, CT-293 PANDUIT Color Code rown Orange Purple Wire Strip Length In. (mm) 5/6 (33.3) 7/8 (47.6) 7/8 (47.6) See pages 5 for PANDUIT and competitor tool and die information. For service and technical support, call (outside the U.S. and Canada, see back c). 39

40 A. Grounding Clamp, U-olt, ronze Used to ground copper conductor parallel or at a right angle to a rod, tube, or pipe Made from high strength, electrolytic cast bronze High strength silicon bronze hardware provides long term reliable assembly Accommodates a wide range of pipe, tube, rod and conductor sizes minimizes inventory UL Listed for grounding and bonding with conductor and suitable for direct burial in earth or concrete H W L Ground Rod Size In. (mm) GPL-8-Q 7/8 or (23) GPL-4-X GPL-5-X GPL-6-X GPL-22-X GPL-28-X GPL-34-3 Iron Pipe Size In. (mm) /2 or 3/4 (20 or 25) (32) (32) (32) /4 (40) /2 (52) 2 (63) Conductor Size Range (mm 2 ) #8 SOL #4 STR (0 SOL 6 STR) #8 SOL #4 STR (0 SOL 6 STR) #4 SOL 2/0 STR (6 STR 70 STR) 2/0 SOL 2 kcmil (70 SOL 27) 2/0 SOL 2 kcmil (70 SOL 27) 2/0 SOL 2 kcmil (70 SOL 27) 2/0 SOL 2 kcmil (70 SOL 27) Figure Dimensions In. (mm) L W H 2.38 (60.5) 2.63 (66.8) 2.63 (66.8) 2.63 (66.8) 3.00 (76.2) 3.25 (82.6) 3.75 (95.3).38 (35.).38 (35.).63 (4.4).88 (47.8).88 (47.8).88 (47.8).88 (47.8) 2.63 (66.8) 2.75 (69.9) 2.75 (69.9) 3.25 (82) 3. (88.9) 4.00 (0.6) 4.25 (07.9) olt Dia. In. (mm) 3/8 (9.5) 3/8 (9.5) 3/8 (9.5) 3/8 (9.5) 3/8 (9.5) 3/8 (9.5) 3/8 (9.5) Hex Size In. (mm) 9/6 (4) 9/6 (4) 9/6 (4) 9/6 (4) 9/6 (4) 9/6 (4) 9/6 (4) Tightening Torque In.-Lbs. (Nm) 0 (2.5) 0 (2.5) 80 (20.5) 80 (2.5) 240 (2.5) 240 (2.5) 240 (2.5) Grounding Clamp for Water Pipes, ronze Used to ground copper code conductor to water pipe or copper tube Cast from high strength, electrolytic bronze to provide reliable grounding connections Plated steel screws provide high strength and inhibit corrosion Accommodates a wide range of pipe, tube, rod and conductor sizes minimizes inventory UL Listed for grounding and bonding with conductor and suitable for direct burial in earth or concrete L W Water Pipe Range In. (mm) KP-C /2 (20 32) KP2-L /4 2 (40 63) Conductor Size Range (mm 2 ) #0 SOL #2 STR (6 SOL 35 STR) #0 SOL #2 STR (6 SOL 35 STR) Figure Dimensions In. (mm) Tightening Torque In.-Lbs. (Nm) L W Conductor Clamp 2.28 (57.9) 3.58 (90.9).66 (6.8).73 (8.5) (5.5) (5.5) (5.5) (5.5) Prime items appear in OL

41 Grounding Clamp for Water Pipes, Aluminum Dual-rated for grounding aluminum or copper code conductors to copper water pipe, galvanized pipe, or steel conduit Made from high strength, extruded aluminum alloy to provide long term durability Tin-plated to inhibit corrosion and oxidation and for low contact resistance Plated steel screws provide high strength and inhibit corrosion Accommodates a wide range of pipe, tube, and conductor sizes minimizes inventory requirements UL Listed for grounding and bonding A. L W Water Pipe Range In. (mm) GC-5A-Q /2 3/4 (20 25) GC-8A-X /4, /2 2 (40 32, 20 63) GC-22A-4 2 /2 3 3 /2 4 ( ) Conductor Size Range (mm2) #4 /0 (2.5 70) #6 2 kcmil (6 ) #6 2 kcmil (6 ) Figure Dimensions In. (mm) Tightening Torque In. Lbs. (Nm) L W Conductor Clamp 2.25 (57.2) 3.75 (95.3) 6.3 (95.3).69 (7.5).8 (20.6).00 (25.4) (5.5) (5.5) (5.5) (5.5) (5.5) (5.5) For service and technical support, call (outside the U.S. and Canada, see back c). 4

42 A. With Split olt, Made from high strength copper alloy to resist corrosion and provide premium electrical and mechanical performance Wire range-taking capability minimizes inventory requirements Nut hex provides correct fit with socket, box, or open end wrenches resulting in proper torquing of electrical connection Pressure bar provides secure connection on a full range of conductor combinations used with each connector assuring premium wire pull-out strength UL Listed and CSA Certified with conductor for use up to 600 V and temperature rated 90 C SCT3-C is tin-plated for bonding to galvanized wire baskets L W E SC3-C SCT3-C Tin-Plated Conductor Range of Equal Run and Tap (mm 2 ) Figure Dimensions In. (mm) Min. Tap with One Max. Run Min. Max. (mm 2 ) E W L UL Listed and CSA Certified with Code Conductors SC3-C #8 STR (0) #4 STR (25) #4 STR (2.5).58 (4.7) UL Listed and CSA Certified with and Aluminum Code Conductors SCT3-C* #8 STR (0) #4 STR (25) #0 STR (6).58 (4.7).8 (20.6).8 (20.6).6 (29.5).24 (3.5) *The use of PANDUIT oxide inhibiting joint compound (CMP-00) is recommended. Refer to for more information. Tightening Torque In.-Lbs. (Nm) 275 (3.) 275 (3.) Hand Operated Plier Type Tools Installer controlled crimp Available with wire stripping and cutting features Plier type crimp for #22 thru #0 insulated and non-insulated terminal products CT-00A Part Description Crimps most PANDUIT #22 #0 insulated and non-insulated terminals, disconnects, and splices. Cuts #4, #6, #8 and #0 screw sizes. Cuts and strips wire. Excellent all-around application tool of heat treated finished steel with comfortable cushioned plastic grip handles. 42 Prime items appear in OL

43 CONTOUR CRIMP Controlled Cycle Tools Specifically designed for the installation of PAN-TERM Terminals, Disconnects, and Splices Controlled cycle mechanism assures high quality, consistent terminations Ergonomic tool design assures operator comfort, safety, and performance Polypropylene handles provide chemical resistance and a cushioned, non-slip grip Multi-position locator facilitates a high quality repeatable crimp A. CT-5 CT-570 CT-5 CT-570 Part Description Crimps most PAN-TERM #22 #0 nylon and vinyl insulated terminals, splices, and disconnects. The CT-5 has the red/blue pocket closest to the pivot which provides a reduced crimp effort for those who make red/blue terminations. Crimps most PAN-TERM #22 #0 and.5 6.0mm² non-insulated terminals and disconnects. Crimps PANDUIT #22 #0 and.5 6.0mm² non-insulated splices and #0 compression lugs. CT-700 Crimps PANDUIT #8 #2 non-insulated tubular terminals (S series), #8 # copper code conductor lugs and splices, #6 #4 dual rated aluminum lugs and splices and CTAPF0-6 to CTAPF3-2 copper taps. Includes 5-position, color-coded rotating die. CT- 700 Die Type, Manual Hydraulic, 4 Ton, Crimping Tool Two-stage rapid advance hydraulic system minimizes number of pumps required to complete a crimp saves time Cushioned grip prevents hands from slipping on tool reduces fatigue Provides UL Listed and CSA Certified connections on PANDUIT PAN-LUG and Aluminum Lugs and Splices and Taps Open C-Head design allows easy loading of crimping dies and connectors, saves time Requires crimping dies, see page 45 Dies installed using spring loaded die retention pins, no need for tools Rubber boot on crimp head provides abrasion protection Audible pop-off valve indicates crimp completion Crimp head rotates 80, provides versatility for use in restricted spaces CT-930 Part Description Terminates PANDUIT PAN-LUG Compression Connectors: compression lugs and splices for #8 7 kcmil (0 300mm²) code conductor compression lugs and splices for #8 600 kcmil (0 300mm²) flex conductor compression CTAPF taps for #0 3/0 (6 70mm²) code conductor compression CTAP taps for #8 4/0 (0 95mm²) code conductor compression HTCT taps for #4 2 kcmil (2.5 25mm²) code conductor, #4 4/0 (2.5 20mm²) flex conductor Aluminum compression lugs and splices for #6 600 kcmil (6 300mm²) code conductor Aluminum compression HTAPs for #4 0 kcmil ( mm²) code conductor PANDUIT PAN-TERM Tubular Terminals for #8 2 kcmil (0 20mm²) code conductor Warranty: 5 years CT-930 includes: Tool Plastic tool case with die storage For service and technical support, call (outside the U.S. and Canada, see back c). 43

44 A. Die Type, attery ed Hydraulic, 2 Ton, Crimping Tool Two-stage rapid advance hydraulic system minimizes cycle time Provides UL Listed and CSA Certified connections on PANDUIT PAN-LUG and Aluminum Lugs and Splices and Taps Open C-Head design allows easy loading of crimping dies and connectors, saves time Rubber boot on crimp head provides abrasion protection Ram automatically retracts when crimp cycle is complete Retraction stop feature allows the installer to pull the trigger and stop the ram from fully retracting to save time and battery charge on multiple crimp scenarios Tool provided with two, high capacity 2 VDC rechargeable nickel-metal hydride batteries provides for continuous operation and eliminates memory build-up, one hour charge time Eight second crimp cycle time provides quick terminations, saves time Uses industry standard MAKITA* batteries and charger industry proven reliability easy to obtain from local retail sources Requires crimping dies, see page 45 Dies installed using spring loaded die retention pins no need for tools Crimp head rotates 360 provides versatility for use in restricted spaces *MAKITA is a registered trademark of Makita Corporation. CT-293 Part Description Terminates PANDUIT PAN-LUG Compression Connectors: compression lugs and splices for #8 7 kcmil (0 300mm²) code conductor compression lugs and splices for #8 600 kcmil (0 300mm²) flex conductor compression CTAPF taps for #0 3/0 (6 70mm²) code conductor compression CTAP taps for #8 4/0 (0 95mm²) code conductor compression HTCT taps for #4 2 kcmil (2.5 25mm²) code conductor, #4 4/0 (2.5 20mm²) flex conductor Aluminum compression lugs and splices for #6 600 kcmil (6 300mm²) code conductor Aluminum compression HTAPs for #4 0 kcmil ( mm²) code conductor PANDUIT PAN-TERM Tubular Terminals for #8 2 kcmil (0 20mm²) code conductor CT-293/E Warranty: 3 years CT-293 includes: Tool Two 2 VDC, rechargeable NiMH batteries One battery charger, 5 V AC Steel tool case with storage for batteries, charger, and crimping dies Tool is CE approved. Terminates PANDUIT PAN-LUG Compression Connectors: compression lugs and splices for #8 7 kcmil (0 300mm²) code conductor compression lugs and splices for #8 600 kcmil (0 300mm²) flex conductor compression CTAPF taps for #0 3/0 (6 70mm²) code conductor compression CTAP taps for #8 4/0 (0 95mm²) code conductor compression HTCT taps for #4 2 kcmil (2.5 25mm²) code conductor, #4 4/0 (2.5 20mm²) flex conductor Aluminum compression lugs and splices for #6 600 kcmil (6 300mm²) code conductor Aluminum compression HTAPs for #4 0 kcmil ( mm²) code conductor PANDUIT PAN-TERM Tubular Terminals for #8 2 kcmil (0 20mm²) code conductor Warranty: 3 years CT-293/E includes: Tool Two 2 VDC, rechargeable NiMH batteries One battery charger, 230 V AC Steel tool case with storage for batteries, charger, and crimping dies 44 Prime items appear in OL

45 CD-920 Crimping Dies Crimping dies and connectors are color-coded for easy matching Emboss die index number on connector barrels for post crimp inspection Part number permanently marked on crimping die for easy identification Die Color Provide circumferential crimp results in terminations with premium electrical and mechanical performance Used in PANDUIT crimping tools; see the CT-930 crimping tool on page 43 and the CT-293 and CT-293/E crimping tools on page 44 A. Die Number CD-920 CD-930H CDM-920 Patented Locator HTAP Die with Patented Locator Used to Install PANDUIT Compression Lug and Splice Sizes Code Conductor Size and Die Color and Die No. Single Crimp Dies CD #8 (0mm²), Red P2 CD #6 (6mm²), lue P24 CD #4 (25mm²), Gray P29 CD #2 (35mm²), rown P33 CD-920- # (35mm²), Green P37 CD-920-/0 /0 (mm²), Pink P42 CD-920-2/0 2/0 (70mm²), lack P45 CD-920-3/0 3/0 (95mm²), Orange P CD-920-4/0 4/0 (95mm²), Purple P54 CD kcmil (20mm²), Yellow P62 Used to Install PANDUIT HTAP s HTAP and Die Color and Die No. Single Crimp Dies with Patented Locator CD-920H-6 HTCT6-6-, Orange PH6 CD-920H-2 HTCT2-2-, rown PH2 CD-930H-2 HTCT2-2-, HTCT2-2-, Purple PH25 Used to Install PANDUIT CTAPF s CTAPF and Die Color and Die No. Multi-Crimp Dies CDM CTAPF4, rown P33M CDM-920-3/0 CTAPF/0, Orange PM CDM-920-4/0 CTAPF2/0, Purple P54M For service and technical support, call (outside the U.S. and Canada, see back c). 45

GROUNDING & BONDING PRODUCTS

GROUNDING & BONDING PRODUCTS GROUNDING & BONDING PRODUCTS Busbars Page 5-3 Insulators Page 5-8 Grounding Products Page 5-9 Compression Tools, Lugs & Taps Page 5-14 Learn About CPI s Extended Limited Warranties for coverage of (2)

More information

Panduit PreConfigured Industrial Distribution Frame (IDF) Installation Instructions Part Numbers ZDF and ZDF

Panduit PreConfigured Industrial Distribution Frame (IDF) Installation Instructions Part Numbers ZDF and ZDF Panduit PreConfigured Industrial Distribution Frame (IDF) Installation Instructions Part Numbers ZDF242430 and ZDF242430-6 Table of Contents Figure 1: Industrial Distribution Frame (IDF) Equipment Elevation

More information

PanView iq (PViQ) Fiber Tray

PanView iq (PViQ) Fiber Tray PVQ-FMT PanView iq (PViQ) Fiber Tray Part Number: PVQ-FMT Contents: 1 - FIBER TRAY (HOUSING & DRAWER) 6 - #12-24 x 1/2" SCREWS 6 - M6 x 1.0 x 16 SCREWS 2 - STRAIN RELIEF BRACKETS 2 - #10-32 BLACK HEX NUTS

More information

Installing Power Components

Installing Power Components This chapter provides instructions on how to install and reinstall power components in the Cisco NCS 4016 chassis. It also covers connecting and disconnecting power and powering on the chassis. The Cisco

More information

Section COMMUNICATION EQUIPMENT ROOM FITTINGS. Section Communications Cabinets, Racks, Frames and Enclosures

Section COMMUNICATION EQUIPMENT ROOM FITTINGS. Section Communications Cabinets, Racks, Frames and Enclosures PART 1 GENERAL 1.1 WORK INCLUDED Section 27 11 00 COMMUNICATION EQUIPMENT ROOM FITTINGS Section 27 11 16 Communications Cabinets, Racks, Frames and Enclosures A. Provide all labor, materials, and equipment

More information

MIGHTY MO CABLE MANAGEMENT SYSTEM

MIGHTY MO CABLE MANAGEMENT SYSTEM MIGHTY MO CABLE MANAGEMENT SYSTEM ONE SIZE FITS ALL Mighty Mo Wall Mount Cabinet Mighty Mo 3 Clear Mighty Mo 4-Mation Mighty Mo 3 www.ortronics.com 800-934-5432 (sales) 877-599-5393 MIGHTY MO 3 CABLE MANAGEMENT

More information

Ortronics. Mighty Mo. GX Cabinets. Designed to Perform, Configured to Fit

Ortronics. Mighty Mo. GX Cabinets. Designed to Perform, Configured to Fit Ortronics Mighty Mo GX Cabinets Designed to Perform, Configured to Fit Mighty Mo GX Configured By You, Made By Legrand Ortronics 2 Ortronics (adj.) ef fi cient Performing or functioning in the best possible

More information

Frequently Asked Questions

Frequently Asked Questions Q. When should I use the Adjustable Quadra? A. Use the Adjustable Quadra with #12-24 threaded equipment mounting holes in network facilities to support patch panels, fiber enclosures and network switches.

More information

ARION: 19 EIA-310E Standard Enclosure

ARION: 19 EIA-310E Standard Enclosure Patents Pending: 1002000994, 1001000784, 1001000785, 1001000786, 1001000787 UL 2416 Approved Part No. TBA Publication Date: March, 2015 User Manual 1 Contents Page Important Safety Information..............................................

More information

Ground Wire Size. 1/2 in /4 in. 2 in /2 in. 3-1/2 in TB. 4 in. 5 in. #4 4/0 AWG 3906-TB

Ground Wire Size. 1/2 in /4 in. 2 in /2 in. 3-1/2 in TB. 4 in. 5 in. #4 4/0 AWG 3906-TB lamps Waterpipe Ground lamps Waterpipe Ground lamps Waterpipe Ground lamps 2-T Ground Wire Size Water Pipe Size 1/2 in., 3/4 in., 1 or rebar 4-10 3-T 1-1/4 in., 1-1/2 in. or 2 in. #6, #4, #2 WG 4 2-1/2

More information

CABINETS, RACKS, AND CABLE MANAGEMENT SOLUTIONS

CABINETS, RACKS, AND CABLE MANAGEMENT SOLUTIONS CABINETS, RACKS, AND CABLE MANAGEMENT SOLUTIONS PANDUIT provides leading edge cabinets, racks, and cable management solutions for telecommunications equipment rooms, data centers, and premise wiring applications.

More information

1.6 Accessories include tool-free snap-in technology options for air flow, cable management, shelves, power distribution units, etc.

1.6 Accessories include tool-free snap-in technology options for air flow, cable management, shelves, power distribution units, etc. Rittal TS IT Rack Guide Specifications TS IT network server enclosure 1.0 General Description 1.1 Modular Free Standing Equipment Cabinet 1.2 Various combinations of dimensions: 1.2.1 Height: 48 /1200mm,

More information

SUBMERSIBLE SECONDARY CONNECTORS SSBC350-4LI. Cond. Range H W L

SUBMERSIBLE SECONDARY CONNECTORS SSBC350-4LI. Cond. Range H W L SUBMERSIBLE SECONDARY CONNECTORS -1- Index TYPE SSBC350-L (Wide-Port Spacing) Rubber Insulated Secondary Connectors SURE-SEAL RUS Approved User friendly wide-port spacing (50% more room for cable training).

More information

Cabinet and Rack Installation

Cabinet and Rack Installation Cabinet and Rack Requirements, page 1 Cisco MDS 9000 Family Telco and EIA Shelf Bracket, page 3 Cabinet and Rack Requirements This section provides the Cisco MDS 9000 Family requirements for the following

More information

HP BladeSystem c7000 Carrier-Grade Options Installation Guide

HP BladeSystem c7000 Carrier-Grade Options Installation Guide HP BladeSystem c7000 Carrier-Grade Options Installation Guide Part Number 5991-8062 September 2009 (Second Edition) Copyright 2009 Hewlett-Packard Development Company, L.P. The information contained herein

More information

Cabinet and Rack Installation

Cabinet and Rack Installation APPENDIXA This appendix includes the following information: Cabinet and Rack Requirements, page A-1 Cisco MDS 9000 Family Telco and EIA Shelf Bracket, page A-3 Cabinet and Rack Requirements This section

More information

6U Vertical Server Cabinet - 30 in. depth

6U Vertical Server Cabinet - 30 in. depth 6U Vertical Server Cabinet - 30 in. depth Product ID: RK630WALVS This 6U vertical server cabinet offers a space-saving way to keep your network and server equipment secure. With its 30 in. depth and a

More information

Motive Cable Management System

Motive Cable Management System Protecting your technology investment. Motive Cable Management System Motive Vertical is a highly configurable and advanced cable management solution that provides unlimited adjustment anywhere within

More information

USpace Midi Cabinet & Midi Server Cabinet Range.

USpace Midi Cabinet & Midi Server Cabinet Range. USpace 7210 19 Midi Cabinet & Midi Server Cabinet Range www.edpeurope.com Overview The USpace 7210 midi cabinet continues the tradition of quality, style and innovation associated with the USystems repertoire

More information

42U Server Rack Cabinet - 37 in. Deep Enclosure

42U Server Rack Cabinet - 37 in. Deep Enclosure 42U Server Rack Cabinet - 37 in. Deep Enclosure Product ID: RK4242BK24 This 42U server rack provides a sleek, secure cabinet for storing standard 19 rack-mount devices such as Dell, HP, and IBM servers,

More information

Grounding Accessories

Grounding Accessories Accessories Eaton offers a variety of grounding which are sold individually or as a kit. Kits are available as one kit per rack, allowing for ease of stocking and reordering. Vertical rack ground bar kit

More information

Number Tube I.P.S. Rod Size or O.D. Range Cable H J W

Number Tube I.P.S. Rod Size or O.D. Range Cable H J W TYPE GAR D-28 FENCE POST GROUNDING CONNECTOR For Parallel or 90 Copper Cable Connection To Rod or Pipe with the Same Connector High copper alloy ground connector for joining a range of cable, parallel

More information

22U 36in Knock-Down Server Rack Cabinet with Casters

22U 36in Knock-Down Server Rack Cabinet with Casters 22U 36in Knock-Down Server Rack Cabinet with Casters Product ID: RK2236BKF This server rack provides 22U of storage space in a sleek secure cabinet for storing EIA-310 compliant 19 rackmount devices such

More information

Server Rack Cabinet - 31 in. Deep Enclosure - 12U

Server Rack Cabinet - 31 in. Deep Enclosure - 12U Server Rack Cabinet - 31 in. Deep Enclosure - 12U Product ID: RK1233BKM This server rack provides 12U of storage space in a sleek, secure cabinet for storing standard 19 rackmount devices such as Dell,

More information

ONTRAC WIRE MESH CABLE TRAY SYSTEM

ONTRAC WIRE MESH CABLE TRAY SYSTEM P R O D U C T D ATA S H E E T ONTRAC WIRE MESH CABLE TRAY SYSTEM K E Y F E AT U R E S Available in two styles: Shaped and Standard Tray Easy to use pathway solution that supports large quantities of network

More information

FiberGuide Fibre Management Systems

FiberGuide Fibre Management Systems FiberGuide Fibre Management Systems Table of Contents Introduction...................................................................... 1 Features and Benefits..............................................................

More information

42U Server Rack Cabinet - 30 in. Extra Wide - 37 in. Deep Enclosure

42U Server Rack Cabinet - 30 in. Extra Wide - 37 in. Deep Enclosure 42U Server Rack Cabinet - 30 in. Extra Wide - 37 in. Deep Enclosure Product ID: RK4242BK30 This 42U server rack provides a sleek, secure cabinet for storing standard 19 rack-mount devices such as Dell,

More information

Installing the Switch Chassis

Installing the Switch Chassis Safety, page 1 Installation Options with Racks and Cabinets, page 2 Airflow Considerations, page 2 Installation Guidelines, page 2 Unpacking and Inspecting the Switch, page 3 Installing the Switch, page

More information

AMP NETCONNECT 19 NETWORK AND SERVER RACK SYSTEM.

AMP NETCONNECT 19 NETWORK AND SERVER RACK SYSTEM. AMP NETCONNECT 19 NETWORK AND SERVER RACK SYSTEM. Product development was driven by the need to solve troubles of cabinet rack usage as well as to provide a cabinet that will efficient networking, reliability,

More information

Panduit PreConfigured ZDF48-RA Industrial Distribution Frame (IDF) Installation Instructions

Panduit PreConfigured ZDF48-RA Industrial Distribution Frame (IDF) Installation Instructions Panduit PreConfigured ZDF48-RA Industrial Distribution Frame (IDF) Installation Instructions Figure 1: Industrial Distribution Frame (IDF) Equipment Elevation V00028CA Rev01 Page 1 of 14 Table of Contents

More information

ELECTRICAL SOLUTIONS C4.1. A. System Overview. B1. Cable Ties. B2. Cable Accessories. B3. Stainless Steel Ties. C1. Wiring Duct. C2.

ELECTRICAL SOLUTIONS C4.1. A. System Overview. B1. Cable Ties. B2. Cable Accessories. B3. Stainless Steel Ties. C1. Wiring Duct. C2. CABLE MANAGEMENT Panduit offers a complete line of cable management products and accessories to route and secure cable. These products are an essential part of a clean, professional installation, which

More information

Copper Bar... ASTM B187, B152 Silicon Bronze... ASTM F468, F467, F651

Copper Bar... ASTM B187, B152 Silicon Bronze... ASTM F468, F467, F651 Eaton offers a range of cable grids and distribution frames to meet various telecommunications applications. Cable grids feature light-weight, yet durable steel c-channel, and are design to support cable

More information

E Series Enclosures Installation Instructions (UL /UL2416 E Series Equipment Cabinet/Rack)

E Series Enclosures Installation Instructions (UL /UL2416 E Series Equipment Cabinet/Rack) E Series Enclosures Installation Instructions (UL60950-1/UL2416 E Series Equipment Cabinet/Rack) WeRackYourWorld.com 1-866-TRY-GLCC (879-4522) Instructions for the following Great Lakes Enclosures: GL720E-2432,

More information

Outlets terminate all shielded and shielded cable constructions AWG ( mm) size conductors.

Outlets terminate all shielded and shielded cable constructions AWG ( mm) size conductors. MAX 5e Shielded Modules The shielded MAX module is the cornerstone of our category 5e screened cabling systems. This product not only meets all TIA/EIA component specifications, but also exceeds ISO/IEC

More information

Bonding & Grounding. Telecommunications Main Ground Bars. Telecommunications Main Ground Bar Kits

Bonding & Grounding. Telecommunications Main Ground Bars. Telecommunications Main Ground Bar Kits PhysicalSupport.D 1/21/08 2:10 PM Page 121 GB4X12TMGB GB4X20TMGB GB4X12TMGBKIT Telecommunications Main Ground Bars and Kits Manufactured of 1/4 thick electrolytic tough pitch 110 alloy copper bar. Includes

More information

RACK SYSTEMS Racks, Rack Enclosures, Cable Managers, Shelves & Accessories

RACK SYSTEMS Racks, Rack Enclosures, Cable Managers, Shelves & Accessories RACK SYSTEMS Racks, Rack Enclosures, Cable Managers, Shelves & Accessories INSIDE SECTION 1: Universal Rack Page 1-3 Standard Rack Page 1-7 Rack Enclosures Page 1-9 QuadraRack, Adjustable Page 1-11 QuadraRack,

More information

TABLE OF CONTENTS FOREWORD...3 INTRODUCTION SCOPE NORMATIVE REFERENCES DEFINITIONS AND ABBREVIATIONS REQUIREMENTS...

TABLE OF CONTENTS FOREWORD...3 INTRODUCTION SCOPE NORMATIVE REFERENCES DEFINITIONS AND ABBREVIATIONS REQUIREMENTS... TITLE SPECIFICATION FOR PORTABLE DATE: JULY 2006 PAGE: 1 OF 25 TABLE OF CONTENTS Page FOREWORD...3 INTRODUCTION...4 1 SCOPE...4 2 NORMATIVE S...4 3 DEFINITIONS AND ABBIATIONS...4 4 REQUIREMENTS...5 4.1

More information

Grounding Solutions for Data Center Applications

Grounding Solutions for Data Center Applications Grounding Solutions for Data Center Applications B D A A C E G F E Legend For Typical Grounding Application (layout on following page) A) B) C) D) E) F) G) Vertical Rack Ground Bar Kit (see page 4) Horizontal

More information

INSTALL INSTRUCTIONS DC C-EV. Installation Instructions: DC C-EV.

INSTALL INSTRUCTIONS DC C-EV. Installation Instructions: DC C-EV. INSTALL INSTRUCTIONS DC6-48-60-0-8C-EV Installation Instructions: DC6-48-60-0-8C-EV INSTALL INSTRUCTIONS DC6-48-60-0-8C-EV Contents Section Description Page 1 Copyright 2 1.1 Disclaimer 2 1.2 Warnings

More information

Knürr Smaract. Knürr Smaract. CompactRack

Knürr Smaract. Knürr Smaract. CompactRack CompactRack Features Ample space for components and cabling provided in an efficient, compact design. The innovative frame concept with triangular extrusions ensures low weight while maintaining high stability.

More information

GT-Series GlobalFrame Gen 2 Cabinet System

GT-Series GlobalFrame Gen 2 Cabinet System Protecting your technology investment. GT-Series GlobalFrame Gen 2 Cabinet System An easy-to-use, computer and network equipment storage cabinet that complies with data center, computer room and premise

More information

Space Saving Cable Management Rack Systems

Space Saving Cable Management Rack Systems Space Saving Cable Management Rack Systems Maximize Space Utilization, Enhance Network Reliability The trend towards consolidation, virtualization and automation in the enterprise is driving the need to

More information

Accessories. Introduction. Cable Hangers LINE PRODUCTS TRANSMISSION

Accessories. Introduction. Cable Hangers LINE PRODUCTS TRANSMISSION Accessories Introduction While a number of cable related accessories are available on the market, RFS components are of the highest quality and are designed to provide years of trouble-free service. Together

More information

General Cable Support Information

General Cable Support Information General Cable Support Information Applications Used to support cables in vertical raceways or risers. Relieves the strain that would be placed on terminations, the interior of panels, or other devices

More information

Voice/Data/ Video Tools

Voice/Data/ Video Tools Voice/Data/ Video Tools Professionals prefer Klein's high quality materials and construction for durable long-lasting tools. Klein VDV Tools provide time savings and reliability, especially in high-volume

More information

SYSTIMAX 360 ipatch G2 Fiber Ultra High Density (UHD) Shelf, LC InstaPATCH Distribution Panel Instructions

SYSTIMAX 360 ipatch G2 Fiber Ultra High Density (UHD) Shelf, LC InstaPATCH Distribution Panel Instructions Instruction Sheet 860564707 Issue 2, January 2014 SYSTIMAX Solutions SYSTIMAX 360 ipatch G2 Fiber Ultra High Density (UHD) Shelf, LC InstaPATCH Distribution Panel Instructions General The SYSTIMAX 360

More information

SECTION 1: Field Inspection Guide for Rooftop Photovoltaic (PV) Systems

SECTION 1: Field Inspection Guide for Rooftop Photovoltaic (PV) Systems COUNTY OF SANTA CRUZ PLANNING DEPARTMENT 701 OCEAN STREET, 4 th FLOOR, SANTA CRUZ, CA 95060 (831) 454-2580 FAX: (831) 454-2131 TDD: (831) 454-2123 KATHLEEN MOLLOY PREVISICH, PLANNING DIRECTOR Photovoltaic

More information

GF-SERIES GLOBALFRAME CABINET SYSTEM

GF-SERIES GLOBALFRAME CABINET SYSTEM P R O D U C T D ATA S H E E T GF-SERIES GLOBALFRAME CABINET SYSTEM K E Y F E AT U R E S Cost-effective cabinet solution adaptable to server, network and mixed-use applications Available in two configurations

More information

Infinity 1U 19 Converter Shelf Models: J L224-48V to +24V, L V to -48V

Infinity 1U 19 Converter Shelf Models: J L224-48V to +24V, L V to -48V GE Critical Power Quick Start Guide Infinity 1U 19 Converter Shelf Models: J5964803 L224-48V to +24V, L225 +24V to -48V Edge Controller example Outputs RTNs Inputs RTNs Refer to Infinity Converter Brochure

More information

Upgrading the Sure Coat Modular Gun Control System

Upgrading the Sure Coat Modular Gun Control System Instruction Sheet P/N 007365B Upgrading the Sure Coat Modular Gun Control System WARNING: Read the Safety section in the Sure Coat Modular Gun Control System manual before performing any of the following

More information

EZTray. Cable Management Made Easy

EZTray. Cable Management Made Easy EZTray Cable Management Made Easy PRESENTATION Introduction:.................................. 3 EZ Tray: The Tray That Saves You Time!.............. 4-5 EZ Tray: The Innovative Cable Management Solution....

More information

Capacitors. Individual & fixed bank. Individual & fixed capacitor banks. Low Voltage Network Quality

Capacitors. Individual & fixed bank. Individual & fixed capacitor banks. Low Voltage Network Quality Individual & fixed capacitor banks Low Voltage L O W V O L T A G E N E T W O R K Q U A L I T Y Individual & fixed bank Capacitors Description High reliability Well proven features of ABB dry type power

More information

SYSTIMAX 360 ipatch InstaPATCH Fiber Shelf Instructions

SYSTIMAX 360 ipatch InstaPATCH Fiber Shelf Instructions Issue 6, June 2014 SYSTIMAX 360 ipatch InstaPATCH Fiber Shelf Instructions General The SYSTIMAX 360 ipatch InstaPATCH fiber shelf is a SYSTIMAX approved product and is available in a sliding configuration

More information

Have You Been Grounded Lately

Have You Been Grounded Lately Have You Been Grounded Lately Thurs, Oct. 26, 2017 9:15-10:15 Phil Simmons Author, Electrical Grounding and Bonding Author Cengage Learning Phil Simmons Have You Been Grounded Lately 2017 NEC Changes Relative

More information

Battery Cables. Wire & Cable

Battery Cables. Wire & Cable Battery Cables Why Use Larger Cable? Low-voltage power systems with inverters can have very high current through the cables that connect the inverter to the batteries. Large AC loads like microwave ovens,

More information

Series 3 & 4 Stainless Steel - Accessories

Series 3 & 4 Stainless Steel - Accessories - Accessories Splice Plates Standard 8-hole pattern for all steel splice plates. One pair including hardware provided with straight section. (Expansion splice quantity subtracted) Boxed in pairs with hardware.

More information

Series 2, 3, 4, & 5 Steel - Accessories

Series 2, 3, 4, & 5 Steel - Accessories - ccessories Splice Plates Standard 8-hole pattern for all steel splice plates. One pair including hardware provided with straight section. Boxed in pairs Expansion Splice Plates Expansion plates allow

More information

T&B Cable Tray. In this section...

T&B Cable Tray. In this section... In this section... T& Cable Tray T& Cable Tray Overview... -260-261 luminum Tray... -262-309 Steel Tray... -310-333 One-Piece Tray... -334-357 Channel Tray... -358-373 Common ccessories... -374-376 Grounding

More information

GE Energy Industrial Solutions. EV Charging Station. Application Guide. imagination at work

GE Energy Industrial Solutions. EV Charging Station. Application Guide. imagination at work GE Energy Industrial Solutions EV Charging Station Application Guide imagination at work EV Charging Station Introduction The GE EV Charging Station offers Level II charging capable of reducing charge

More information

Route/Protect C For service and technical support, call A. System Overview B1. Cable. Ties B2. Cable.

Route/Protect C For service and technical support, call A. System Overview B1. Cable. Ties B2. Cable. Route/Protect A. Panduit offers a complete line of cable management products and accessories to route and secure cable. These products are an essential part of a clean, professional installation, which

More information

Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility

Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility Catalog 2800CT1001R04/12 2012 Class 2800 CONTENTS Description............................................ Page 2 Indoor Charging

More information

Fully assembled, ready-to-use custom cabinets.

Fully assembled, ready-to-use custom cabinets. EC42U3042 EC45U2442 EC24U2442 EC45U2436 EC45U3042 EC38U3032 EC45U3032 EC45U3048 EC42U2442 EC45U3036 Elite Cabinet/Rack User s Manual Fully assembled, ready-to-use custom cabinets. You chose your options,

More information

Chapter 3. Installing Equipment

Chapter 3. Installing Equipment TERAFRAME USER S MANUAL 57 Chapter 3. Installing Equipment 3.1 EQUIPMENT MOUNTING RAILS Four vertical equipment mounting rails are installed at the factory, two in the front of the cabinet and two in the

More information

Dual-Feed 200A 4/5 TPA/GMT Fuse Alarm Panel. Model Installation Guide

Dual-Feed 200A 4/5 TPA/GMT Fuse Alarm Panel. Model Installation Guide Dual-Feed 200A 4/5 TPA/GMT Fuse Alarm Panel Model 009-8005-0404 Installation Guide Dual-Feed 200A 4/5 TPA/GMT Fuse Alarm Panel Model 009-8005-0404 Installation Guide, Part number 123518-6 Copyright 2010,

More information

Space Saving Cable Management Rack Systems

Space Saving Cable Management Rack Systems Space Saving Cable Management Rack Systems Maximize Space Utilization, Enhance Network Reliability The trend towards consolidation, virtualization and automation in the enterprise is driving the need to

More information

Series 2, 3, 4, & 5 Aluminum - Accessories

Series 2, 3, 4, & 5 Aluminum - Accessories The following is a list of accessories and fittings that can be provided with S8 tray. For more information on these items, contact our Engineering Department. Fittings Horizontal Bends 30 Bends with 24,

More information

EVlink Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility

EVlink Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility EVlink Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility Catalog 2800CT1001 2014 Class 2800 CONTENTS Description............................................ Page 2 Outdoor

More information

Duct System for a Server or Switch Cabinet Mounted Cisco 4900M (CNLTD21B2)

Duct System for a Server or Switch Cabinet Mounted Cisco 4900M (CNLTD21B2) Duct System for a Server or Switch Cabinet Mounted Cisco 4900M (CNLTD21B2) Panduit Corp. 2012 INSTALLATION INSTRUCTIONS 4900M Duct (Installed in Net-Access Cabinet.) Switch Cabinet Application Server Cabinet

More information

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5 DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5 1.1. APPLICABLE PUBLICATIONS 1.1.1. Publications listed below (including amendments, addenda, revisions, supplements, and errata), form a part of this

More information

Connector Installation Guide Compression and Mechanical Connectors

Connector Installation Guide Compression and Mechanical Connectors Connector Installation Guide Compression and Mechanical Connectors Typical Cross Section of a Compression Connector Before Installation Before compression, a typical cross section of cable consists of

More information

EMC Compatible enclosure assembly

EMC Compatible enclosure assembly EMC Compatible enclosure assembly 1 The definition of electromagnetic compatibility (EMC) is the ability of an electrical device to function satisfactorily in its electromagnetic environment without adversely

More information

B T T T 2.11 MY29-11 (1) 4/0 AWG - MY29-11 (1) W30VT (2) U30RT (2) 300 kcmil 150 W30VT (2) YA30L-2TC W30RT (2) U28ART (2)

B T T T 2.11 MY29-11 (1) 4/0 AWG - MY29-11 (1) W30VT (2) U30RT (2) 300 kcmil 150 W30VT (2) YA30L-2TC W30RT (2) U28ART (2) URNDY TWO HOLE HYLUG CODE CONDUCTOR STANDARD ARREL (Continued) T T T Fig. 1 Fig. 2 Fig. 3 Conductor Installation Tooling Stud Stud Figure Mechanical Hydraulic Wire Fig *** Hole Hole Tongue Dimensions Dieless

More information

any server any environment one source

any server any environment one source any server any environment one source For more information, please contact WDM, Inc. Phone: (800) 448-1881 or (650) 363-2791 Fax: (650) 363-2825 www.wdminc.com or e-mail to info@wdminc.com legendary reliability

More information

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards 1 General 1.1 Switchboards shall be U.L. listed and labeled. 1.2 Each switchboard shall have its own main disconnecting means unless it is located in the same room as its source of origin. In most cases

More information

BURNDY Compression. TWO HOLE HYLUG CODE CONDUCTOR STANDARD BARREL (Continued) Fig. 1 Fig. 2 Fig. 3. Conductor

BURNDY Compression. TWO HOLE HYLUG CODE CONDUCTOR STANDARD BARREL (Continued) Fig. 1 Fig. 2 Fig. 3. Conductor URNDY TWO HOLE HYLUG CODE CONDUCTOR STANDARD ARREL (Continued) T T T Fig. 1 Fig. 2 Fig. 3 C-46 Conductor Installation Tooling Stud Stud Figure Mechanical Hydraulic Wire Fig *** Hole Hole Tongue Dimensions

More information

2000 Cooper Bussmann, Inc. Page 1 of 9 10/04/00

2000 Cooper Bussmann, Inc. Page 1 of 9 10/04/00 DO YOU KNOW THE FACTS ABOUT SINGLE-POLE INTERRUPTING RATINGS? YOU MAY BE IN TROUBLE! Typical plant electrical systems use three-phase distribution schemes. As an industry practice, short-circuit calculations

More information

GMT Fuse Panel Installation Guide

GMT Fuse Panel Installation Guide GMT Fuse Panel Installation Guide Document INS-707XXXXXXX This manual covers the following part numbers- Trimm 707XXXXXXX Family Table of Contents Section 1- General Information... 3 1.1 - Product Description...

More information

CTN U-TYPE DIE COLOR INDEX QTY 7/374 8/346 11/375 12/ /298 18/324 19/470 20/299 22/472 24/473 CTN U-TYPE DIE COLOR INDEX QTY

CTN U-TYPE DIE COLOR INDEX QTY 7/374 8/346 11/375 12/ /298 18/324 19/470 20/299 22/472 24/473 CTN U-TYPE DIE COLOR INDEX QTY PAGE 2 PEEP HOLE STANDARD BARREL COPPER LUGS Allows inspection of the termination to assure complete cable insertion GL SERIES One-Hole 32000 GL 80 32002 GL 84 3999 GL 0 32004 GL 4 3200 GL 5 32003 GL 38

More information

Install the Shelf and Common Control Cards

Install the Shelf and Common Control Cards CHAPTER 1 This chapter explains how to install the Cisco ONS 15454 ETSI and Cisco ONS 15454 ANSI shelf assemblies. Where procedures differ for the two shelf types, the procedure will indicate ANSI only

More information

Application Specification Circular Plastic Connector (CPC) Series 45 System 05 AUG 14 Rev D

Application Specification Circular Plastic Connector (CPC) Series 45 System 05 AUG 14 Rev D Application Specification Circular Plastic Connector (CPC) 114-13137 Series 45 System 05 AUG 14 Rev D NOTE i All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS 144F TABLE OF CONTENTS GENERAL... 2 SPECIFICATIONS... 2 PACKAGE CONTENTS... 2 PACKAGE CONTENTS: ACCESSORIES... 3 REQUIRED TOOLS... 3 ADD-ON COMPONENTS... 3 CABINET MOUNTING WALL MOUNT BRACKET ATTACHMENT...

More information

Overview. Chassis Packaging

Overview. Chassis Packaging This chapter provides an overview of the Cisco NCS 6000 Series Routers. The Cisco NCS 6000 Series Routers include the Cisco NCS 6008 Line Chassis (LCC) and the Cisco NCS 6000 Fabric Card Chassis (FCC).

More information

Universal Network Zone System Part Numbers: Z23U-****

Universal Network Zone System Part Numbers: Z23U-**** Universal Network Zone System Part Numbers: Z23U-**** Page 1 of 13 TABLE OF CONTENTS Overview of Products Safety Information / Warnings Specs / Tools Needed Wall Mounting Bracket Installation Wall Mounting

More information

THE NEW TS IT RACK 8

THE NEW TS IT RACK 8 THE NEW TS IT RACK 8 Fast and reliable Fast Loosen the 48. (9 ) quickrelease fastener, slide into the correct position, and latch Reliable Maximum load capacity up to,000 N Convenience in perfection Interior

More information

Connecting to DC Power

Connecting to DC Power APPENDIXC This appendix describes how to make DC power connections to the Catalyst 3750G-12S-SD switch. See the Installing the Switch section on page 2-11 for instructions on installing the switch. To

More information

Series 2, 3, 4, & 5 Aluminum - Accessories

Series 2, 3, 4, & 5 Aluminum - Accessories Wedge Lock Splice Plates Standard 4-hole pattern. Furnished in pairs, with hardware. One pair including hardware provided with each section. Boxed in pairs with hardware. For field installation drill 13

More information

Your Global Flow Control Partner. Series 70 24V On/Off Electric Actuator Operation and Maintenance Manual

Your Global Flow Control Partner. Series 70 24V On/Off Electric Actuator Operation and Maintenance Manual Your Global Flow Control Partner Series 70 Table of Contents 1. Definition of Terms.......................................2 2. Safety............................................. 2 3. Storage............................................2

More information

Series 70 24V On/Off Electric Actuator Operation and Maintenance Manual

Series 70 24V On/Off Electric Actuator Operation and Maintenance Manual Series 70 Operation and Maintenance Manual TABLE OF CONTENTS 1. Definition of Terms............................................. 1 2. Safety................................................... 1 3. Storage..................................................

More information

Cabinet and Rack Installation

Cabinet and Rack Installation APPENDIXA This appendix provides information on how to install cabinet and rack, and includes the following sections: Cabinet and Rack Requirements, page A-1 Cisco MDS 9000 Family telco and EIA Shelf Bracket,

More information

In This Section. and. Fittings & Non-Metallic Rigid Conduit Fittings and Accessories. Steel City Fittings

In This Section. and. Fittings & Non-Metallic Rigid Conduit Fittings and Accessories. Steel City Fittings In This Section and Steel City Overview...F-2 F-3 Thinwall Conduit (EMT)...F-4 F-9 Rigid/Intermediate Grade Conduit...F-0 7 Flexible Cord and Power Cable Connectors...F-8 Liquidtight Flexible Metal Conduit

More information

Switchgear Skid, C1192

Switchgear Skid, C1192 CUSTOM SOLUTIONS 15kV Modular Stairs stored on floor in front of battery bay Ground grid stored on front tongue of trailer Stairs deployed for unit access Storage box for fencing materials and other parts

More information

50A Dual-Feed 5/5 GMT Total Front Access Fuse Panel

50A Dual-Feed 5/5 GMT Total Front Access Fuse Panel 50A Dual-Feed 5/5 GMT Total Front Access Fuse Panel Power :: GMT05FA User Manual Applys to : GMT05FA Table of Contents 1.1 Overview...3 1.2 Rack-mounting Considerations...4 1.3 Specifications...4 1.4 Installation...6

More information

SunLink PV System Disconnect with Arc Fault Detection Installation and Operations Manual

SunLink PV System Disconnect with Arc Fault Detection Installation and Operations Manual Combiner Box Installation & Operations Manual SunLink PV System Disconnect with Arc Fault Detection Installation and Operations Manual TABLE OF CONTENTS Notices and Safety Precautions Pages 1-2 Combiner

More information

Electric Vehicle Charging Station

Electric Vehicle Charging Station EVoReel Electric Vehicle Charging Station INSTALLATION GUIDE AND USER MANUAL Model: Dual Output Pedestal Mount 30A EVoReel EVSE Model Numbers: With Basic EVSE: EV072-400-002A; With Intelligent ievse: EV072-410-002A;

More information

Cabinet and Rack Installation

Cabinet and Rack Installation APPENDIX A This appendix provides the following information: Cabinet and Rack Requirements, page A-1 Cisco MDS 9000 Family Telco and EIA Shelf Bracket, page A-4 Cabinet and Rack Requirements This section

More information

Series 1 Steel - Accessories

Series 1 Steel - Accessories - ccessories Standard (L-Shaped) Splice Plates One pair including hardware provided with each section. Prepackaged in pairs in a plastic bag, with hardware. 4-hole pattern L-shaped splice plates. L-shaped

More information

Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility

Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility Catalog 2800CT1001 2011 Class 2800 CONTENTS Description............................................ Page 3 Catalog Numbering

More information

Eclipse Hermetic Gas Boosters

Eclipse Hermetic Gas Boosters Information Guide 620 12/1/2008 Eclipse Hermetic Gas Boosters Series HB & HBLC Version 1 Applications Eclipse Inc., produces a line of single stage, centrifugal type, hermetically sealed gas boosters for

More information

Total Front Access Wall Mount Fuse Panel Installation Guide. Document INS This manual covers the following part numbers

Total Front Access Wall Mount Fuse Panel Installation Guide. Document INS This manual covers the following part numbers Total Front Access Wall Mount Fuse Panel Installation Guide Document INS-7473121031 This manual covers the following part numbers- 7473121031 Table of Contents Section 1- General Information... 3 1.1 -

More information

INLET DUCT FOR CISCO 9513 SWITCH Part Number: DIBBC2314S21W

INLET DUCT FOR CISCO 9513 SWITCH Part Number: DIBBC2314S21W INLET DUCT FOR CISCO 9513 SWITCH Part Number: DIBBC2314S21W Panduit Corp. 2012 INSTALLATION INSTRUCTIONS For Either a Net-Access Legacy or Net-Access N-Type Switch Cabinet (CN** OR N**) 9513 Inlet Duct

More information